Está en la página 1de 2

DISEO DE VIGA

1.0 DATOS
b=

30 cm

Base

H=

60 cm

Altura

Mu =

30 Ton-m

Momento Ultimo

fc =

210 kg/cm2

fy =

4200 kg/cm2

0.9

Resistencia Concreto
Resistencia Acero
Coeficiente

n=

1 cm

Numero de capas

e=

4 cm

Recubrimiento

d=

54 cm

Peralte efectivo

2.0 CALCULOS
2.1 CALCULO DE CUANTIA MECNICA ()
_= ^( ) ^ (. )
1 = 0.207

2 = 1.488

Usamos:

0.207

2.2 CALCULO DE CUANTIA ()


= ^ /
=

0.0103

min =

0.0033

3.0 DISEO
2.3 CALCULO DE AREA DE ACERO (As)
=
As =

16.74

cm2

As min=

5.35

cm2

ACERO MINIMO
# Aceros

D (cm)

A (cm)

1/8

0.318

1/4

ACERO DE REFUERZO
AREA

# Aceros

D (cm)

A (cm)

0.079

1/8

0.318

0.079

0.635

0.317

1/4

0.635

0.317

3/8

0.953

0.713

3/8

0.953

0.713

1/2

1.270

1.267

1/2

1.270

1.267

5/8

1.588

1.979

5/8

1.588

1.979

3/4

1.905

2.850

3/4

1.905

2.850

5.700

2.540

5.067

2.540

5.067

1 1/4

3.175

7.917

1 1/4

3.175

7.917

1 1/2

3.810

11.401

1 1/2

3.810

11.401

TOTAL

5.700

CORRECTO

# Aceros CORRECTO

TOTAL
# Aceros CORRECTO

USAR :

63/4

UERZO
AREA

11.401

11.401 CORRECTO