Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Departamento de Recambios
Tel. 902 400 744 | Fax 902 314 514
e-mail: recambios.aire@sp.mee.com
econsumo
Consultas Tcnicas
Tel. 902 400 744
e-mail: serviaire@sp.mee.com
econfort
ecompromiso
15/6/10 16:26:41
15/6/10 16:26:43
ndice
TECNOLOGA REPLACE ............................................................. 2
OPCIONALES ............................................................................... 6
DATOS DE INSTALACIN
Gama Domstica .......................................................................................
Gama Mr. Slim ...........................................................................................
Gama Industrial ..........................................................................................
Presiones Estticas de Unidades de Conductos ......................................
Air to Water ................................................................................................
12
14
24
28
29
CDIGOS DE INSPECCIN
SMS .............................................................................................. 32
Gama Domstica ....................................................................................... 34
Gama Mr. Slim ........................................................................................... 38
Gama Industrial .......................................................................................... 38
MODO DE MANTENIMIENTO FCIL
Gama Mr. Slim ...........................................................................................
Gama Industrial ..........................................................................................
Monitor .......................................................................................................
Lista de cdigos de requerimiento ............................................................
Extraccin de datos con el PAC-SK52 ......................................................
40
40
42
43
48
CONFIGURACIN DE FUNCIONES
Gama Mr. Slim ........................................................................................... 57
Gama Industrial .......................................................................................... 57
AGENDA ....................................................................................... 64
GARANTIA / CONTACTO ............................................................. 67
Los datos referentes a los modelos publicados en este catlogo sustituyen a los de anteriores ediciones
15/6/10 16:26:43
Tecnologa Replace
QU ES LA TECNOLOGA REPLACE?
REPLACE es una tecnologa exclusiva de Mitsubishi Electric y nica en el mercado que permite
reemplazar un equipo de aire acondicionado antiguo por otro de ltima generacin, reutilizando las conexiones
frigorficas, elctricas y de control, sin tener que limpiarlas o adaptndolas a una preinstalacin ya existente.
Contramedidas Problema 1
TECNOLOGA 1
Problema 1
Problema 2
Resultado
Refrigerante R22
Alta temperatura de
trabajo
Nuevo equipo
R410A (sin Replace)
Temperatura func.
del compresor
aumenta
Residuos de
cloro
Contramedidas Problema 2
TECNOLOGA 2
Reduccin de Friccin (mejora del compresor)
El deterioro del aceite se produce por la suma de los dos problemas, eliminando uno de ellos se anula la degradacin.
Tecnologa 1
Aceite HAB del refrigerente
Tecnologa 2
Reduccin de Friccin del Compresor
La friccin entre los componentes del compresor se reducen
usando la tecnologa exclusiva de Mitsubishi Electric Heat
Caulking Fixing Method que impide el aumento de la temperatura, causante del deterioro del aceite del compresor.
15/6/10 16:26:43
DOMSTICA MR.SLIM
INDUSTRIAL
INSTALACIN MS
FCIL Y RPIDA
Reutilizacin de las tuberas existentes.
Simplifica tiempos de instalacin
y de interrupcin de
la actividad.
RESPETO AL
MEDIOAMBIENTE
Gran reduccin de
costes por no generar
residuos.
60
45
REDUCCIN
DE COSTES
OFF
ON
Reduccin de
emisiones CO2
y mejora de la
eficiencia energtica.
15
30
GAMA DISPONIBLE
La Tecnologa REPLACE Cleaning Free & Pipe Reuse puede
aplicarse en todos nuestros modelos Inverter de la Gama
Domstica, Comercial (Mr.SLIM) e Industrial.
Series disponibles
Gama
Domstica
Interior
Exterior
MSZ - FD / GE / HC
MUZ - FD / GE / HC MXZ (excepto -8A)
Mr. Slim
Interior
Exterior
PEAD
Industrial
Interior
Exterior
PEA
PUHZ - RP / P
PLA
PKA
PCA
PUHZ - HRP / RP / P
PSA
SUZ-KA
CI
Ozone
O O
CI
CI
C
CFC-11 CI
Freon
CCIF
O
O
CI
CI
CI
C
CI
Oxygen
Chlorine
Chlorine monoxide
CIO
Oxygen
Ultraviolet ray
Oxygen
O
15/6/10 16:26:49
Tecnologa Replace
Gama Domstica
MSZ-FD20/35/50VA(S)
MSZ-GE22/35/42/50VA
Unidad exterior
MUZ-FD
MXZ-2B
MXZ-3B
MXZ-4B
MXZ-5B
MXZ-8A
MSZ-GA60/71VA
MUZ-GE
MXZ-2B
MXZ-3B
MXZ-4B
MXZ-5B
Unidad interior
MSHGE50VB
MSHGA60VB
MSHGD80VB
MS-GE50VB
MS-GA60VB
MS-GD80VB
Unidad exterior
MUH-GE
MUH-GA
MUH-GD
MU-GE
MU-GA
MU-GD
MXZ-8A
MUZ-GA
MXZ-4B
MXZ-5B
MSZ-HC25/35VA(B)
MSC-GE20/25/35VB
MUZ-HC
MUZ-HC
MXZ-8A
MU-GA
MLZ-25/35/50VA
MFZ-25/35/50VA
SUZ-KA
MXZ-2B
MXZ-3B
MXZ-4B
MXZ-5B
MXZ-8A
MXZ-2B
MXZ-3B
MXZ-4B
MXZ-5B
S-Series
Unidad interior
SLZ-KA25/35/50VA
SLZ-KA25/35/50VAL
SEZ-KD25/35/50/60/71VA
SEZ-KD25/35/50/60/71VAL
Unidad exterior
SUZ-KA
SUZ-KA
SUZ-KA
SUZ-KA
NO
El dimetro exterior y el grosor de la tubera actual no
cumplen las especificaciones o se han observado daos.
NO
Nivel 0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
Inicio de uso
Color recogido
en el frasco
El dimetro de la tubera actual corresponde al tamao del nuevo sistema de aire acondicionado?
SI
NO
Importante
Utilice juntas de dimetro distinto o cambie el tamao
mediante soldadura fuerte.
Ciclo de prueba
15/6/10 16:26:50
Tecnologa Replace
PLA-RP35/50/60/71/100/125/140BA(2/3)
Unidad exterior
PUHZ-HRP PUHZ-RP
PUHZ-P
SUZ-KA
Unidad interior
PKA-RP60/71/100KAL
Unidad exterior
PUHZ-HRP PUHZ-RP
PUHZ-P
PUH-P
PEAD-RP35/50/60/71/100/125/140JA(L)
PUH-P
PU-P
PUHZ-HRP
PUHZ-RP
PUHZ-P
SUZ-KA
PCA-RP50/60/71/100/125/140KA
PU-P
PUHZ-HRP
PUHZ-RP
PUHZ-P
PUH-P
PUH-P
PEA-RP200/250/400/500GA
PU-P
PUHZ-RP
PUHZ-RP
PUHZ-RP
PKA-RP35/50HAL
PU-P
PUHZ-RP
PUHZ-P
PKA-RP35/50HAL
PUHZ-RP
PUH-P
PKA-RP35/50HAL
PU-P
PUHZ-P
PUHZ-P
PUH-P
PU-P
Consulte el diagrama siguiente para determinar si pueden reutilizarse las tuberas actuales.
Si el dimetro de las tuberas actuales no se corresponde con el tamao especificado, consulte los Datos Tecnolgicos del Material en
las pginas del 10 al 13 para determinar si es posible reutilizar las tuberas.
Nivel 0
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
Inicio de uso
Color recogido
en el frasco
El dimetro de la tubera actual corresponde al tamao del nuevo sistema de aire acondicionado?
SI
NO
Ciclo de prueba
15/6/10 16:26:51
Opcionales
OPCIONALES
MSZ-FD / FA / GE
MSZ-GC / GB VA / GA VA
MFZ-KA VA
SEZ-KD
SLZ-KA
Mr. SLIM en KW
MAC-397IF
MAC-399IF
MAC-821SC
PAC-SE55
PAC-SA88HA-E
PAC-SF40
ME-AC/KNX1
MR. SLIM
PAC-SF81
PAC-SK52
INDUSTRIAL
PUHZ-HRP
PUH-P
PUHZ-RP
PUHZ-P
PUH-P
PUHZ-RP
PUHZ-P
MXZ-8A140VA
GAMA DOMSTICA
MAC-397IF
Interface para conectar un mando PAR-21MAA a una unidad de domstico DC inverter.
Interface para conectar un mando de 8 ON/OFF MAC-821SC-E.
Interface que admite seales externas (Domtica).
Seales de entrada:
- On/Off
- Cambio Fro/Calor
- Cambio de Temperaturas de consigna (20/24/28C o desde 16C hasta 30C)
Seales de Salida:
- Estado ON/OFF o Funcionamiento CORRECTO/AVERA
CN591
TB571
TB580
1 2
EJEMPLO FUNCIN N6
Existen 7 funciones diferentes.
Para otras funciones consultar
con el departamento tcnico.
15/6/10 16:26:52
MAC-399IF
Interface para la conversin de Control A domstico a la lnea de Control M-NET.
(Permite conectar un PAR-F27MEA o cualquier control centralizado de la Gama MELANS)
MAC-821SC
Control centralizado ON/OFF para 8 unidades interiores control A domstico.
(Se requiere adems un MAC-397IF para cada unidad interior a controlar)
GAMA MR.SLIM
CONTROL A
PAC-SF81MA-E
Interface para la conversin de Mr. Slim Control A a la lnea de control M-NET.
(Permite conectar cualquier control de la Gama MELANS)
* Vlido para toda la Gama Mr. Slim Control A, excepto las SUZ.
PAC-SC51KUA
Fuente de Alimentacin
15/6/10 16:26:54
Opcionales
PAC-SE55
FUNCIN
Tipo de seal
Conector
Opcional
Limitaciones
Compatible con
CN32
1
Opcional
PCB U. Int.
1
Con esta configuracin el mando queda prohibido mientras el contacto Y esta abierto.
CN32
Circuito a
realizar por
el instalador
PCB U. Int.
1
X
Circuito a
realizar por
el instalador
PCB U. Int.
1
Circuito a
realizar por
el instalador
X
3
contacto X.
15/6/10 16:27:02
PAC-SA88HA-E
Conector de 5 hilos, para realizar ON/OFF por pulso, seal de Operacin ON/OFF y seal de avera a distancia.
Se conecta en el conector CN51 de la placa de la unidad interior.
*Vlido para toda la Gama Mr. Slim Control A en KW
PAC-SF40RM-E
Interface para seales externas para realizar ON/OFF por pulso, seal de Operacin ON/OFF y seal de avera a distancia.
Se conecta en el conector CN90 y CN41 de la placa de la unidad interior.
*Vlido para toda la Gama Mr. Slim Control A
*Si dispone de mando inalmbrico, deber instalar un mando por cable
1 PULSO ON
1 PULSO OFF
( 1 segundo )
PAC-SF40RM-E
230 VAC
24 VDC
12 VDC
Manguera de 2m incluida
230 VAC
24 VDC
12 VDC
15/6/10 16:27:02
Tecnologa Replace
Opcionales
PAC-SK52ST
Con esta interface de inspeccin de unidades dispondr de toda la informacin sobre todas las sondas de temperaturas exteriores e
interiores, presiones, abertura de vlvula de expansin, frecuencia de inverter, velocidad ventiladores, etc.
EJEMPLOS DE VISUALIZACIN
SW2 montaje
Detalle a inspeccionar
Unidad
89
PAC-SK52ST
Modificando el micro-interruptor SW2 del PAC-SK52ST podr visualizar todos los parmetros internos de la Unidad exterior e interior.
Sondas de temperatura.
Velocidad ventilador.
Frecuencia compresor.
Recalentamientos y sub-enfriamientos.
10
15/6/10 16:27:05
Datos de Instalacin
Gama Domstica
DC INVERTER
I.C.P.
(Ver tabla)
230-I
DATOS DE INSTALACIN
Mximo 30 m
Mximo 50 m
SECCIN A mm2
SECCIN B mm2
MSZ-FD 25 VA
2 x 2,5 + T
MSZ-FD 35 VA
2 x 2,5 + T
MSZ-FD 50 VA
Intensidad Mxima
(A)
3 x 2,5 + T
10
3 x 2,5 + T
10
2x4+T
3 x 2,5 + T
MSZ-GE 25 VA
2 x 2,5 + T
MSZ-GE 35 VA
MODELO
Tubera Frigorfica
Lquido
Gas
Vertical (m)
Total (m)
16
6,35 (1/4)
9,52 (3/8)
12
20
16
6,35 (1/4)
9,52 (3/8)
12
20
16
20
6,35 (1/4)
12,7 (1/2)
15
30
3 x 2,5 + T
7,4
16
6,35 (1/4)
9,52 (3/8)
12
20
2 x 2,5 + T
3 x 2,5 + T
8,6
16
6,35 (1/4)
9,52 (3/8)
12
20
MSZ-GE 42 VA
2x4+T
3 x 2,5 + T
10
20
6,35 (1/4)
9,52 (3/8)
12
20
MSZ-GE 50 VA
2x4+T
3 x 2,5 + T
13
20
6,35 (1/4)
12,7 (1/2)
15
30
MSZ-GE 60 VA
2x4+T
3 x 2,5 + T
14,5
20
6,35 (1/4)
15,88 (5/8)
15
30
MSZ-GE 71 VA
2x4+T
3 x 2,5 + T
16,6
20
9,52 (3/8)
15,88 (5/8)
15
30
DC INVERTER
I.C.P.
(Ver tabla)
230-I
DATOS DE INSTALACIN
Mximo 30 m
Mximo 50 m
MODELO
Intensidad Mxima
(A)
ICP. (A)
Curva C
Tubera Frigorfica
SECCIN A mm
SECCIN B mm
Lquido
Gas
Vertical (m)
Total (m)
MFZ-KA 25 VA
2 x 2,5 + T
3 x 2,5 + T
8,8
16
6,35 (1/4)
9,52 (3/8)
12
20
MFZ-KA 35 VA
2 x 2,5 + T
3 x 2,5 + T
9,7
16
6,35 (1/4)
9,52 (3/8)
12
20
MFZ-KA 50 VA
2x4+T
3 x 2,5 + T
17
20
6,35 (1/4)
12,7 (1/2)
15
30
NOTAS: Para longitudes superiores consultar las tablas de las pginas 30 y 31.
11
15/6/10 16:27:07
Datos de Instalacin
MULTI SPLIT 2x1/3x1/4x1/5x1
MULTI DC INVERTER
MXZ-
MXZ2B40VA
MXZ2B52VA
MXZ3B54VA
MXZ3B68VA
MXZ4B71VA
MXZ4B80VA
MXZ5B100VA
20
30
30
50
50
60
70
80
15
20
20
25
25
25
25
25
10
15
15
15
15
15
15
15
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
20
20
25
25
25
25
25
20
30
30
50
50
60
70
80
Unidad (D)
Unidad (C)
Unidad (B)
Unidad (D)
DATOS DE INSTALACIN
MODELO
Mximo 30 m
Mximo 50 m
SECCIN A mm2
SECCIN B mm2
MXZ-2B30VA
2 x 2,5 + T
3 x 2,5 + T
16
MXZ-2B40VA
2 x 2,5 + T
3 x 2,5 + T
10,2
16
MXZ-2B52VA
2 x 2,5 + T
3 x 2,5 + T
10,2
16
MXZ-3B54VA
2x4+T
3 x 2,5 + T
15
20
MXZ-3B68VA
2x4+T
3 x 2,5 + T
15
20
MXZ-4B71VA
2x4+T
3 x 2,5 + T
15
20
MXZ-4B80VA
2x4+T
3 x 2,5 + T
17,4
20
MXZ-5B100VA
2x4+T
3 x 2,5 + T
18,4
20
CARGA ADICIONAL
MODELO
15 / 20 / 22 / 25 / 35 / 42
50
60
71
MODELO
Pre-carga
20m
30m
40m
50m
60m
70m
Lquido
6,35 (1/4)
MXZ-2B30VA
1150
Gas
9,52 (3/8)
MXZ-2B40VA
1300
200
Lquido
6,35 (1/4)
MXZ-2B52VA
1300
200
Gas
12,7 (1/2)
MXZ-3B54VA
2700
200
Lquido
6,35 (1/4)
MXZ-3B68VA
2700
200
Gas
15,88 (5/8)
MXZ-4B71VA
2700
200
400
Lquido
9,52 (3/8)
MXZ-4B80VA
3500
200
400
600
Gas
15,88 (5/8)
MXZ-5B100VA
4000
200
400
600
80m
800
Unidad B
Unidad C
Unidad D
Unidad E
MXZ-2B30VA
MXZ-2B40VA
MXZ-2B52VA
MXZ-3B54VA
MXZ-3B68VA
MXZ-4B71VA
MXZ-4B80VA
MXZ-5B100VA
Lquido
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
Gas
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
12,7 (1/2)
12,7 (1/2)
12,7 (1/2)
Lquido
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
Gas
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
Lquido
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
Gas
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
Lquido
6,35 (1/4)
6,35 (1/4)
6,35 (1/4)
Gas
9,52 (3/8)
9,52 (3/8)
9,52 (3/8)
Lquido
6,35 (1/4)
Gas
9,52 (3/8)
(1) El dimetro de tubera a instalar siempre ser el de la unidad interior. Las reducciones, si son necesarias, se harn en la entrada de la unidad exterior.
(2) Las unidades de mayor potencia, se deben conectar en las conexiones A y B.
(3) En el caso de ser potencias interiores iguales, las de mayor distancia se conectarn en A y B.
12
15/6/10 16:27:11
Gama Domstica
DC INVERTER
DATOS DE INSTALACIN
Mximo 30 m
MODELO
Mximo 50 m
Tubera frigorfica
SECCIN B mm2
2 x 10 + T
3 x 2,5 + T
MXZ-2A30VA
29,5
32
Gas
3/8
5/8
Unidad B
Unidad C
Unidad D
Unidad E
PAC-AK50BC
PAC-AK30BC
Lquido
6,35 (1/4)
6,35 (1/4)
Gas
9,52 (3/8)
9,52 (3/8)
Lquido
6,35 (1/4)
6,35 (1/4)
Gas
9,52 (3/8)
9,52 (3/8)
Lquido
6,35 (1/4)
6,35 (1/4)
Gas
9,52 (3/8)
9,52 (3/8)
Lquido
6,35 (1/4)
Gas
9,52 (3/8)
Lquido
6,35 (1/4)
12,7 (1/2)
Gas
NOTAS: Necesaria toma de desage
MODELO
15 / 20 / 22 / 25 / 35 / 42
50
60
71
Lquido
6,35 (1/4)
Gas
9,52 (3/8)
Lquido
6,35 (1/4)
Gas
12,7 (1/2)
Lquido
6,35 (1/4)
Gas
15,88 (5/8)
Lquido
9,52 (3/8)
Gas
15,88 (5/8)
40 m o menos
41 - 50 m
51 - 70 m
71 - 90 m
0,9 kg
1,7 kg
2,5 kg
3,5 kg
Carga total
8,5 kg
9,4 kg
10,2 kg
11,0 kg
12,0 kg
DISTANCIAS TOTALES
Tramos
Metros
(A + B + C + D + E + F + G + H + I + J)
115
(A + B)
55
(C + D + E + F + G + H + I + J)
60
(slo C, D, E, F, G, H, I, J)
15
De Distribuidor a Interiores
De Exterior a Interiores
Diferencia de altura
Distancia ms larga
70
Exterior - Interiores
30*
Exterior - Distribuidor
30
Distribuidor - Interiores
15
Interior - Interior
12
91 - 115 m
13
15/6/10 16:27:14
Datos de Instalacin
Serie ZUBADAN
CONTROL
A
PEAD-RP Split Conductos
I.C.P.
(Ver tabla)
PUHZ-HRP71VHA
PUHZ-HRP100VHA
PUHZ-HRP100YHA
PUHZ-HRP125YHA
DATOS DE INSTALACIN
Seccin para un mximo de 50 m
MODELO
SECCIN A mm
SECCIN B mm
Intensidad mxima
(A)
ICP (A)
Curvas (C)
Tubera Frigorfica
Lquido
Gas
Vertical
Total
N
curvas
Precarga de gas
hasta (kg)
Carga
adicional
71V
2 x 10 + T
3 x 2,5 +T
31,5
32
3/8
5/8
30
75
15
30
Ver tabla
100V
2 x 16 + T
3 x 2,5 +T
37,7
40
3/8
5/8
30
75
15
30
Ver tabla
100Y
3x4+N+T
3 x 2,5 +T
16
20
3/8
5/8
30
75
15
30
Ver tabla
125Y
3x4+N+T
3 x 2,5 +T
16
20
3/8
5/8
30
75
15
30
Ver tabla
N de
curvaturas
Diferencia
de altura
15
30 m o inferior
Precarga
5,5 Kg
Cantidad de carga refrigerante adicional para una longitud del conducto que supere los 30 m (kg)
31 - 40 m
41 - 50 m
51 - 60 m
61 - 75 m
0,6 Kg
1,2 Kg
1,8 Kg
2,4 Kg
14
15/6/10 16:27:19
Unidad Interior
PUHZ-RP35VHA
PUHZ-RP50VHA
I.C.P.
(Ver tabla)
PUHZ-RP60VHA
PUHZ-RP71VHA
PUHZ-RP100VKA
PUHZ-RP125VKA
PUHZ-RP140VKA
PUHZ-RP100YKA
PUHZ-RP125YKA
PSA-RP
Split Vertical
PUHZ-RP140YKA
I.C.P.
(Ver tabla)
El circuito frigorfico con LEV (Vlvula Expansin Lineal) y un gran acumulador controlan siempre el nivel ptimo de refrigerante sin tener en cuenta la longitud de tubera ( 30 m mx. y 5 m mn. ) sin necesidad de aadir
ms gas. Para longitudes superiores a 30 mts.
DATOS DE INSTALACIN
Seccin para un mximo de 50 m
MODELO
SECCIN A mm
SECCIN B mm
Intensidad mxima
(A)
ICP (A)
Curvas (C)
Tubera Frigorfica
Lquido
Gas
Vertical
Total
N
curvas
Precarga de gas
hasta (kg)
Carga
adicional
35V
2x4+T
3 x 2,5 +T
14,1
20
1/4
1/2
30
50
15
30
Ver tabla
50V
2x4+T
3 x 2,5 +T
14,1
20
1/4
1/2
30
50
15
30
Ver tabla
60V
2x6+T
3 x 2,5 +T
20,6
25
3/8
5/8
30
50
15
30
Ver tabla
71V
2x6+T
3 x 2,5 +T
21
25
3/8
5/8
30
50
15
30
Ver tabla
100V
2 x 10 + T
3 x 2,5 +T
29,2
32
3/8
5/8
30
75
15
30
Ver tabla
125V
2 x 10 + T
3 x 2,5 +T
29,3
32
3/8
5/8
30
75
15
30
Ver tabla
140V
2 x 10 + T
3 x 2,5 +T
30,8
32
3/8
5/8
30
75
15
30
Ver tabla
100Y
3 x 2,5 + N + T
3 x 2,5 +T
10,7
16
3/8
5/8
30
75
15
30
Ver tabla
125Y
3x4+N+T
3 x 2,5 +T
12,3
20
3/8
5/8
30
75
15
30
Ver tabla
140Y
3x4+N+T
3 x 2,5 +T
13,8
20
3/8
5/8
30
75
15
30
Ver tabla
N de
curvaturas
Diferencia
de altura
30 m o inferior
Precarga
Cantidad de carga refrigerante adicional para una longitud del conducto que supere los 30 m (kg)
31 - 40 m
41 - 50 m
51 - 60 m
61 - 75 m
PUHZ-RP 35/50
2,5 Kg
50 m o inferior
0,2 Kg
0,4 Kg
15
PUHZ-RP 60/71
3,5 Kg
50 m o inferior
0,6 Kg
1,2 Kg
15
30 m o inferior
PUHZ-RP 100/125/140
5,0 Kg
75 m o inferior
0,6 Kg
1,2 Kg
1,8 Kg
2,4 Kg
15
30 m o inferior
15
15/6/10 16:27:25
Datos de Instalacin
Serie STANDARD INVERTER
CONTROL
Unidad Interior
230V
PKA-RP Split Pared
I.C.P.
(Ver tabla)
Diferencial
Unidades Exteriores
PSA-RP
Split Vertical
SUZ-KA35/50/60/71VA
PUHZ-P100/125/140VHA
El circuito frigorfico con LEV (Vlvula Expansin Lineal) y un gran acumulador controlan siempre el nivel ptimo de refrigerante sin tener en cuenta la longitud de tubera ( 30 m mx. y 5 m mn. ) sin necesidad de aadir ms gas.
Para longitudes superiores a 30 mts, consulte la tabla inferior.
DATOS DE INSTALACIN
Seccin para un mximo de 50 m
MODELO
SECCIN A mm
SECCIN B mm
Intensidad mxima
(A)
ICP (A)
Curvas (C)
Tubera Frigorfica
Lquido
Gas
Vertical
Total
N
curvas
Precarga de gas
hasta (kg)
Carga
adicional
35
2 x 4 +T
3 x 2,5 +T
10,3
20
1/4
3/8
12
20
10
Ver tabla
50
2 x 6 +T
3 x 2,5 +T
17,4
25
1/4
1/2
30
30
10
Ver tabla
60
2 x 6 +T
3 x 2,5 +T
17,6
25
1/4
5/8
30
30
10
Ver tabla
71
2 x 6 +T
3 x 2,5 +T
18
25
3/8
5/8
30
30
10
Ver tabla
100 V
2 x 10 +T
3 x 2,5 +T
30,7
32
3/8
5/8
30
50
15
20
Ver tabla
125 V
2 x 10 +T
3 x 2,5 +T
30,8
32
3/8
5/8
30
50
15
30
Ver tabla
140 V
2 x 16 +T
3 x 2,5 +T
32,2
40
3/8
5/8
30
50
15
30
Ver tabla
100 Y
3 x 4 + N +T
3 x 2,5 +T
15,7
20
3/8
5/8
30
50
15
20
Ver tabla
125 Y
3 x 4 + N +T
3 x 2,5 +T
15,8
20
3/8
5/8
30
50
15
30
Ver tabla
20
3/8
5/8
30
50
15
30
Ver tabla
140 Y
3 x 2,5 +T
3 x 4 + N +T
15,8
NOTAS: Para longitudes superiores consultar tablas de las pginas 30 y 31.
Precarga
7m
10 m
15 m
20 m
25 m
SUZ-KA35VA
1050
150
300
450
--
--
SUZ-KA50VA
1600
60
160
260
360
460
SUZ-KA60VA
1800
60
160
260
360
460
SUZ-KA71VA
2000
170
440
720
990
1270
30 m
Carga Adicional
20 m
30 m
40 m
50 m
PUHZ-P100VHA
2900
3000
700
1.300
1.900
PUHZ-P125VHA
4300
4400
4600
800
1.400
PUHZ-P140VHA
4300
4400
4600
800
1.400
16
15/6/10 16:27:31
(MONOFSICO)
Slo en el caso de que la unidad interior disponga de resistencias elctricas de apoyo, deber
alimentarse tambin la unidad interior con 230V y dotar a esta de su correspondiente seccin de
cable, as como su correspondiente proteccin elctrica, lnea C.
Unidad Interior
R-410
Resistencias
Electricas
230V
Diferencial
I.C.P.
(Ver tabla)
PSA-RP
Split Vertical
El circuito frigorfico con LEV (Vlvula Expansin Lineal) y un gran acumulador controlan siempre el nivel ptimo de refrigerante sin tener en cuenta la longitud de tubera ( 20/30 m
mx. y 5 m mn ) sin necesidad de aadir ms gas. Para longitudes superiores a 30 mts.
DATOS DE INSTALACIN
Mximo 30 m
Mximo 50 m
SECCIN A mm2
SECCIN B mm2
MODELO
Punta de arranque
(A)
Tubera Frigorfica
N de
curvas
Precarga
hasta
(kg)
Lquido
Gas
Vertical
Total
71V
2 x 10 + T
3 x 2,5 +T
25,5
32
3/8
5/8
50
50
12
30
100V
2 x 10 + T
3 x 2,5 +T
31,2
32
3/8
5/8
50
50
15
30
NOTAS: Para longitudes superiores consultar las tablas de las pginas 30 y 31.
17
15/6/10 16:27:37
Datos de Instalacin
BOMBA DE CALOR
CONTROL
(TRIFSICO)
Slo en el caso de que la unidad interior disponga de resistencias elctricas de apoyo, deber alimentarse
tambin la unidad interior con 230V y dotar a esta de su correspondiente seccin de cable, as como su
correspondiente proteccin elctrica, lnea C.
Unidad Interior
R-410
Resistencias
Electricas
400V
Diferencial
I.C.P.
(Ver tabla)
PCA-RP Split Techo
PSA-RP
Split Vertical
El circuito frigorfico con LEV (Vlvula Expansin Lineal) y un gran acumulador controlan siempre el nivel ptimo de refrigerante sin tener en cuenta la longitud de
tubera ( 20/30 m mx. y 5 m mn ) sin necesidad de aadir ms gas. Para longitudes superiores a 30 mts, consulte la tabla de la pag. 12.
PUH-P140YHA
DATOS DE INSTALACIN
Mximo 30 m
Mximo 50 m
MODELO
SECCIN A mm2
Punta de arranque
(A)
SECCIN B mm2
Tubera Frigorfica
Lquido
Gas
Vertical
Total
N
curvas
Precarga
de gas
hasta
(kg)
Carga
adicional
71Y
3 x 2,5 + T + N
3 x 2,5 +T
9,8
16
3/8
5/8
50
50
12
30
Ver tabla
100Y
3 x 2,5 + T + N
3 x 2,5 +T
12,1
16
3/8
5/8
50
50
15
30
Ver tabla
125Y
3x4+T+N
3 x 2,5 +T
15,4
20
3/8
5/8
50
50
15
30
Ver tabla
140Y
3x4+T+N
3 x 2,5 +T
18,4
20
3/8
5/8
50
50
15
30
Ver tabla
NOTAS: Para longitudes superiores consultar las tablas de las pginas 30 y 31.
31 - 40 m
41 - 50 m
PUH-P71VHA/YHA
50 m o menos
3,6 Kg
4,2 Kg
4,8 Kg
PUH-P100VHA/YHA
50 m o menos
4,4 Kg
5,0 Kg
5,6 Kg
PUH-P125/140YHA
50 m o menos
5,0 Kg
5,6 Kg
6,2 Kg
UNIDAD EXTERIOR
18
15/6/10 16:27:42
INVERTER S-Series
I.C.P.
(Ver tabla)
230-I
DATOS DE INSTALACIN
Mximo 30 m
Mximo 50 m
SECCIN A mm2
SECCIN B mm2
SLZ-KA 25VAL
2 x 2,5 + T
3 x 2,5 +T
8,5
SLZ-KA 35VAL
2 x 2,5 + T
3 x 2,5 +T
9,6
SLZ-KA 50VAL
2x4+T
3 x 2,5 +T
16,7
MODELO
Intensidad Mxima
(A)
Tubera Frigorfica
Carga
adicional
20
Ver tabla
20
Ver tabla
30
Ver tabla
Gas
Vertical (m)
Total (m)
16
6,35 (1/4)
9,52 (3/8)
12
16
6,35 (1/4)
9,52 (3/8)
12
20
6,35 (1/4)
12,7 (1/2)
30
NOTAS: Para longitudes superiores consultar las tablas de las pginas 30 y 31.
CARGA ADICIONAL DE REFRIGERANTE:
SLZ-KA25/35VAL: Para distancias frigorficas superiores a 7m. aadir 60 gr + 30 gr/m adicional de R-410a.
SLZ-KA50VAL: Para distancias frigorficas superiores a 7m. aadir 20 gr/m adicional de R-410a.
INVERTER S-Series
I.C.P.
(Ver tabla)
230-I
DATOS DE INSTALACIN
Mximo 30 m
Mximo 50 m
SECCIN A mm2
SECCIN B mm2
SEZ-KD 25YA
2 x 2,5 + T
3 x 2,5 +T
8,6
SEZ-KD 35YA
2 x 2,5 + T
3 x 2,5 +T
9,7
SEZ-KD 50YA
2x4+T
3 x 2,5 +T
SEZ-KD 60YA
2x4+T
SEZ-KD 71YA
2x4+T
MODELO
Intensidad Mxima
(A)
Tubera Frigorfica
Carga
adicional
20
Ver tabla
20
Ver tabla
30
30
Ver tabla
15,88 (5/8)
30
30
Ver tabla
15,88 (5/8)
30
30
Ver tabla
Gas
Vertical (m)
Total (m)
16
6,35 (1/4)
9,52 (3/8)
12
16
6,35 (1/4)
9,52 (3/8)
12
16,7
20
6,35 (1/4)
12,7 (1/2)
3 x 2,5 +T
16,7
20
6,35 (1/4)
3 x 2,5 +T
16,9
20
9,52 (3/8)
NOTAS: Para longitudes superiores consultar las tablas de las pginas 30 y 31.
Precarga
7m
10 m
15 m
20 m
SUZ-KA35VA
25 m
30 m
1050
150
300
450
--
--
SUZ-KA50VA
1600
60
160
260
360
460
SUZ-KA60VA
1800
60
160
260
360
460
SUZ-KA71VA
2000
170
440
720
990
1270
19
15/6/10 16:27:47
Datos de Instalacin
Serie COMPO MULTI ZUBADAN 2x1
Lnea de transmisin
Cable 3 hilos
Mando a
distancia
Alimentacin
Electrica
230V 400V
segn modelos
Unidad
exterior
2x1
MODELO
71 / 100 / 125
Longitud mxima
A + B: mx. 75 m
A + C: mx. 75 m
EXTERIORES
INTERIORES
KIT DISTRIBUIDOR
PUHZ-HRP71
35 + 35
MSDD-50TR-E
PUHZ-HRP100
50 + 50
MSDD-50TR-E
PUHZ-HRP125
60 + 60
MSDD-50TR-E
Diferencias
entre distancias
Logitud total
A + B + C : mx. 75 m
B - C: mx. 8 m
Exterior - Interior
H: mx. 30 m
Interior - Interior
N de curvas
h: mx. 1 m
A + B + C: mx. 15
A + B A + C : mx. 8
NOTAS: En el sistema COMPO las unidades interiores funcionarn siempre con un slo control remoto, simultneamente, y nunca de forma independiente. Se recomienda utilizar control remoto de pared.
Todas las series llevan incorporado de serie el control de condensacin.
CONTROL A
Conexionado de control y limitaciones de tubera frigorfica
IMPORTANTE: Siempre funcionarn las dos, tres o cuatro unidades interiores a la vez con un solo control remoto.
Bajo ningn concepto instale dos o tres controles remotos.
NOTA: Las unidades interiores se codifican automticamente. Slo se alimentan elctricamente las unidades exteriores (en el caso de tener unidades interiores con
resistencias elctricas de apoyo, stas tambin debern ser alimentadas elctricamente).
Precarga
5,5 Kg
Cantidad de carga refrigerante adicional para una longitud del conducto que supere los 30 m (kg)
31 - 40 m
41 - 50 m
51 - 60 m
61 - 75 m
0,6 Kg
1,2 Kg
1,8 Kg
2,4 Kg
N de
curvaturas
Diferencia
de altura
15
30 m o inferior
20
15/6/10 16:27:49
Lnea de transmisin
Cable 3 hilos
Mando a
distancia
Alimentacin
Electrica
230V 400V
segn modelos
Unidad
exterior
2x1
EXTERIORES
INTERIORES
KIT DISTRIBUIDOR
PUHZ-RP71
35 + 35
MSDD-50TR-E
PUHZ-RP100
50 + 50
MSDD-50TR-E
PUHZ-RP125
60 + 60
MSDD-50TR-E
PUHZ-RP140
71 + 71
MSDD-50TR-E
Longitud de la tubera
MODELO
Longitud mxima
71
100/125/140
Diferencias de altura
Diferencias
entre distancias
Logitud total
Exterior - Interior
Interior - Interior
N de curvas
A + B: mx. 50 m
A + C: mx. 50 m
A + B + C: mx. 50 m
B - C: mx. 8 m
H: mx. 30 m
h: mx. 1 m
A + B + C: mx. 15
A + B A + C: mx. 8
A + B: mx. 75 m
A + C: mx. 75 m
A + B + C: mx. 75 m
B - C: mx. 8 m
H: mx. 30 m
h: mx. 1 m
A + B + C: mx. 15
A + B A + C: mx. 8
3x1
EXTERIORES
INTERIORES
KIT DISTRIBUIDOR
PUHZ-RP140
50 + 50 + 50
MSDT-111R-E
Diferencias de altura
Longitud de la tubera
MODELO
Longitud mxima
140
A + B: mx. 75 m
A + C: mx. 75 m
A + D: mx. 75 m
Diferencias
entre distancias
Logitud total
B - C: mx. 8 m
B - D: mx. 8 m
C - D: mx. 8 m
A + B + C + D: mx. 75 m
Exterior - Interior
H: mx. 30 m
Interior - Interior
N de curvas
h: mx. 1 m
A + B + C: mx. 15
A + B A + C A + D: mx. 8
NOTAS: En el sistema COMPO las unidades interiores funcionarn siempre con un slo control remoto, simultneamente, y nunca de forma independiente. Se recomienda utilizar control remoto de pared.
Todas las series llevan incorporado de serie el control de condensacin.
CONTROL A
Conexionado de control y limitaciones de tubera frigorfica
IMPORTANTE: Siempre funcionarn las dos, tres o cuatro unidades interiores a la vez con un solo control remoto.
Bajo ningn concepto instale dos o tres controles remotos.
NOTA: Las unidades interiores se codifican automticamente.
Slo se alimentan elctricamente las unidades exteriores (en el caso de tener unidades interiores con resistencias elctricas de apoyo, stas tambin debern ser alimentadas elctricamente).
N de
curvaturas
Diferencia
de altura
15
30 m o inferior
15
30 m o inferior
2,4 Kg
15
30 m o inferior
Unidad exterior
Precarga
31 - 40 m
41 - 50 m
51 - 60 m
61 - 75 m
PUHZ-RP 35/50
2,5 Kg
50 m o inferior
0,2 Kg
0,4 Kg
PUHZ-RP 60/71
3,5 Kg
50 m o inferior
0,6 Kg
1,2 Kg
PUHZ-RP 100/125/140
5,0 Kg
75 m o inferior
0,6 Kg
1,2 Kg
1,8 Kg
21
15/6/10 16:27:53
Datos de Instalacin
Serie COMPO MULTI STANDARD INVERTER 2x1/3x1
Unidades
Interiores
Lnea de transmisin
Cable 3 hilos
Mando a
distancia
Alimentacin
Electrica
230V 400V
segn modelos
Unidad
exterior
2x1
EXTERIORES
INTERIORES
PUHZ-P100
50 + 50
MSDD-50TR-E
PUHZ-P125
60 + 60
MSDD-50TR-E
PUHZ-P140
71 + 71
MSDD-50TR-E
Longitud de la tubera
MODELO
Longitud mxima
KIT DISTRIBUIDOR
Diferencias de altura
Diferencias
entre distancias
Logitud total
Exterior - Interior
Interior - Interior
N de curvas
100
A + B: mx. 50 m
A + C: mx. 50 m
A + B + C: mx. 50 m
B - C: mx. 8 m
H: mx. 30 m
h: mx. 1 m
A + B + C: mx. 15
A + B A + C: mx. 8
125/140
A + B: mx. 50 m
A + C: mx. 50 m
A + B + C: mx. 50 m
B - C: mx. 8 m
H: mx. 30 m
h: mx. 1 m
A + B + C: mx. 15
A + B A + C: mx. 8
3x1
EXTERIORES
PUHZ-P140
INTERIORES
KIT DISTRIBUIDOR
50 + 50 + 50
MSDT-111R-E
Longitud de la tubera
MODELO
Longitud mxima
140
A + B: mx. 50 m
A + C: mx. 50 m
A + D: mx. 50 m
Diferencias de altura
Diferencias
entre distancias
Logitud total
A + B + C + D: mx. 50 m
Exterior - Interior
B - C: mx. 8 m
B - D: mx. 8 m
C - D: mx. 8 m
H: mx. 30 m
Interior - Interior
N de curvas
h: mx. 1 m
A + B + C: mx. 15
A + B A + C A + D: mx. 8
NOTAS: En el sistema COMPO las unidades interiores funcionarn siempre con un slo control remoto, simultneamente, y nunca de forma independiente. Se recomienda utilizar control remoto de pared.
Todas las series llevan incorporado de serie el control de condensacin.
CONTROL A
Conexionado de control y limitaciones de tubera frigorfica
IMPORTANTE: Siempre funcionarn las dos, tres o cuatro unidades interiores a la vez con un solo control remoto.
Bajo ningn concepto instale dos o tres controles remotos.
NOTA: Las unidades interiores se codifican automticamente.
Slo se alimentan elctricamente las unidades exteriores (en el caso de tener unidades interiores con resistencias elctricas de apoyo, stas tambin debern ser alimentadas elctricamente).
Carga Adicional
20 m
30 m
40 m
50 m
PUHZ-P100VHA
2900
3000
700
1.300
1.900
PUHZ-P125VHA
4300
4400
4600
800
1.400
PUHZ-P140VHA
4300
4400
4600
800
1.400
22
15/6/10 16:27:59
Lnea de transmisin
Cable 3 hilos
Mando a
distancia
Alimentacin
Electrica
230V 400V
segn modelos
Unidad
exterior
2x1
EXTERIORES
INTERIORES
KIT DISTRIBUIDOR
PUH-P71
35 + 35
MSDD-50TR-E
PUH-P100
50 + 50
MSDD-50TR-E
PUH-P125
60 + 60
MSDD-50TR-E
PUH-P140
71 + 71
MSDD-50TR-E
Longitud de la tubera
MODELO
Diferencias de altura
Longitud mxima
Logitud total
Diferencias
entre distancias
Exterior - Interior
Interior - Interior
N de curvas
A + B: mx. 50 m
A + C: mx. 50 m
A + B + C: mx. 50 m
B - C: mx. 8 m
H: mx. 40 m
h: mx. 1 m
A + B + C: mx. 15
A + B A + C: mx. 8
3x1
EXTERIORES
INTERIORES
PUH-P140
35 + 35 + 71
SDT-112SA-E
PUH-P140
50 + 50 + 50
MSDT-111R-E
Longitud de la tubera
MODELO
140
KIT DISTRIBUIDOR
Diferencias de altura
Longitud mxima
Logitud total
Diferencias
entre distancias
Exterior - Interior
Interior - Interior
A + B: mx. 50 m
A + C: mx. 50 m
A + D: mx. 50 m
A + B + C + D: mx. 50 m
B - C: mx. 8 m
B - D: mx. 8 m
C - D: mx. 8 m
H: mx. 40 m
h: mx. 1 m
N de curvas
A + B + C: mx. 15
A + B A + C A + D: mx. 8
NOTAS: En el sistema COMPO las unidades interiores funcionarn siempre con un slo control remoto, simultneamente, y nunca de forma independiente. Se recomienda utilizar control remoto de pared.
Todas las series llevan incorporado de serie el control de condensacin.
CONTROL A
Conexionado de control y limitaciones de tubera frigorfica
IMPORTANTE: Siempre funcionarn las dos, tres o cuatro unidades interiores a la vez con un solo control remoto.
Bajo ningn concepto instale dos o tres controles remotos.
NOTA: Las unidades interiores se codifican automticamente.
Slo se alimentan elctricamente las unidades exteriores (en el caso de tener unidades interiores con resistencias elctricas de apoyo, stas tambin debern ser alimentadas elctricamente).
31 - 40 m
41 - 50 m
PUH-P71VHA/YHA
50 m o menos
3,6 Kg
4,2 Kg
4,8 Kg
PUH-P100VHA/YHA
50 m o menos
4,4 Kg
5,0 Kg
5,6 Kg
PUH-P125/140YHA
50 m o menos
5,0 Kg
5,6 Kg
6,2 Kg
UNIDAD EXTERIOR
23
15/6/10 16:28:02
Datos de Instalacin
Serie POWER INVERTER
CONTROL
400-V
400-V
I.C.P.
(Ver tabla)
I.C.P.
(5A)
DATOS DE INSTALACIN
SECCIN A mm2
SECCIN B mm2
SECCIN C mm2
Intensidad
Mxima
(A)
PEZ-200YKA
3x6+N+T
3 x 2,5 + N +T
3 x 2,5 +T
19
PEZ-250YKA
3 x 10 + N + T
3 x 2,5 + N +T
3 x 2,5 +T
21
Mximo de 30 m
Mximo de 50 m
MODELO
Tubera Frigorfica
Lquido
Gas
Vertical (m)
Total (m)
N de
curvas
Precarga de gas
hasta (kg)
Carga
adicional
25
3/8
30
120
15
30
Ver tabla
32
1/2
30
120
15
30
Ver tabla
ICP. (A)
Curva C
NOTAS: Para longitudes superiores consultar las tablas de las pginas 30 y 31.
CONTROL
400-V 400-V
I.C.P.
(Ver tabla)
Unidad ext. 1
I.C.P.
P400(5A)
P500(10A)
400-V
BORNE TB4-1
Unidad ext. 2
I.C.P.
(Ver tabla)
BORNE TB4-2
DATOS DE INSTALACIN
Mximo de 30 m
Mximo de 50 m
MODELO
SECCIN A mm
SECCIN B mm
SECCIN C mm
Intensidad
Mxima
(A)
ICP. (A)
Curva C
Tubera Frigorfica
Lquido
Gas
Vertical (m)
Total (m)
N de
curvas
Precarga de gas
hasta (kg)
Carga
adicional
PEZ-400YKA
3x6+N+Tx2
3 x 2,5 + N + T
3 x 2,5 + T x 2
19 x 2
25 x 2
3/8 x 2
1 x 2
30
120
15
30
Ver tabla
PEZ-500YKA
3 x 10 + N + T x 2
3 x 2,5 + N + T
3 x 2,5 + T x 2
21 x 2
32 x 2
1/2 x 2
1 x 2
30
120
15
30
Ver tabla
NOTAS: Para longitudes superiores consultar las tablas de las pginas 30 y 31.
A+B+C+D
Unidad externa
En el momento
del envo (kg)
RP - 200
6,5 Kg
RP - 250
7,1 Kg
cantidad de carga
adicional
(kg)
No requiere carga
adicional
31- 40 m
41 - 50 m
51- 60 m
61 - 70 m
71 - 120 m
0,9 Kg
1,8 Kg
2,7 Kg
3,6 Kg
1,2 Kg
2,4 Kg
3,6 Kg
4,8 Kg
3,6 (kg)
24
15/6/10 16:28:05
Gama Industrial
2x1
EXTERIORES
INTERIORES
KIT DISTRIBUIDOR
PUHZ-RP200YHA
100 + 100
MSDD-50WR-E
PUHZ-RP250YHA
125 + 125
MSDD-50WR-E
Longitud de la tubera
MODELO
200 / 250
Diferencias de altura
Longitud mxima
Logitud total
Diferencias
entre distancias
A + B: mx. 100 m
A + C: mx. 100 m
A + B + C: mx. 120 m
B - C: mx. 8 m
Exterior - Interior
Interior - Interior
H: mx. 30 m
h: mx. 1 m
N de curvas
mx. 15
3x1
EXTERIORES
INTERIORES
KIT DISTRIBUIDOR
PUHZ-RP200YHA
60 + 60 + 60
MSDT-111R-E
PUHZ-RP250YHA
71 + 71 + 71
MSDT-111R-E
Longitud de la tubera
Diferencias de altura
MODELO
Longitud mxima
200 / 250
Diferencias
entre distancias
Logitud total
A + B: mx. 100 m
A + C: mx. 100 m
A + D: mx. 100 m
B - C: mx. 8 m
B - C: mx. 8 m
B - C: mx. 8 m
A + B + C + D: mx. 120 m
Exterior - Interior
Interior - Interior
N de curvas
H: mx. 30 m
h: mx. 1 m
mx. 15
4x1
EXTERIORES
INTERIORES
KIT DISTRIBUIDOR
PUHZ-RP200YHA
50 + 50 + 50 + 50
MSDF-1111R-E
PUHZ-RP250YHA
60 + 60 + 60 + 60
MSDF-1111R-E
Longitud de la tubera
MODELO
Longitud mxima
200 / 250
A + B: mx. 100 m
A + C: mx. 100 m
A + D: mx. 100 m
A + E: mx. 100 m
Logitud total
A + B + C + D + E: mx. 120 m
Diferencias de altura
Diferencias
entre distancias
B - C: mx. 8 m
B - D: mx. 8 m
B - E: mx. 8 m
C - D: mx. 8 m
C - E: mx. 8 m
D - E: mx. 8 m
Exterior - Interior
Interior - Interior
H: mx. 30 m
h: mx. 1 m
N de curvas
mx. 15m
NOTAS: Todas las series llevan incorporado de serie el control de condensacin. El precio de las combinaciones con Evaporadoras de la serie PLA incluyen el grill.
En el sistema COMPO las unidades interiores funcionarn siempre con un slo control remoto, simultneamente, y nunca de forma independiente. Se recomienda utilizar control remoto de pared.
CONTROL A
Conexionado de control y limitaciones de tubera frigorfica
IMPORTANTE: Siempre funcionarn las dos, tres o cuatro unidades interiores a la vez con un solo control remoto. Bajo ningn concepto instale dos o tres controles remotos.
NOTA: Las unidades interiores se codifican automticamente.
Slo se alimentan elctricamente las unidades exteriores (en el caso de tener unidades interiores con resistencias elctricas de apoyo, stas tambin debern ser alimentadas elctricamente).
A+B+C+D
Unidad externa
En el momento
del envo (kg)
RP - 200
6,5 Kg
RP - 250
7,1 Kg
cantidad de carga
adicional
(kg)
No requiere carga
adicional
31- 40 m
41 - 50 m
51- 60 m
61 - 70 m
71 - 120 m
0,9 Kg
1,8 Kg
2,7 Kg
3,6 Kg
1,2 Kg
2,4 Kg
3,6 Kg
4,8 Kg
3,6 (kg)
25
15/6/10 16:28:07
Datos de Instalacin
Serie STANDARD INVERTER
CONTROL
400-V
400-V
I.C.P.
(Ver tabla)
I.C.P.
(5A)
DATOS DE INSTALACIN
SECCIN B mm
SECCIN C mm
Intensidad
Mxima
(A)
Mximo de 30 m
Mximo de 50 m
MODELO
SECCIN A mm
ICP. (A)
Curva C
Tubera Frigorfica
Lquido
Gas
Total (m)
N de
curvas
Precarga de gas
hasta (kg)
Carga
adicional
SPEZ-200YHA
3x6+N+T
3 x 2,5 + N +T
3 x 2,5 +T
19
25
3/8
30
70
15
30
Ver tabla
SPEZ-250YHA
3 x 10 + N + T
3 x 2,5 + N +T
3 x 2,5 +T
21
32
1/2
30
70
15
30
Ver tabla
NOTAS: Para longitudes superiores consultar las tablas de las pginas 30 y 31.
400-V 400-V
I.C.P.
(Ver tabla)
Unidad ext. 1
I.C.P.
P400(5A)
P500(10A)
400-V
BORNE TB4-1
Unidad ext. 2
I.C.P.
(Ver tabla)
BORNE TB4-2
DATOS DE INSTALACIN
Mximo de 30 m
SECCIN B mm2
SECCIN C mm2
Intensidad
Mxima
(A)
Mximo de 50 m
MODELO
SECCIN A mm2
ICP. (A)
Curva C
Tubera Frigorfica
Lquido
Gas
Vertical (m)
Total (m)
N de
curvas
Precarga de gas
hasta (kg)
Carga
adicional
SPEZ-400YHA
3x6+N+Tx2
3 x 2,5 + N + T
3 x 2,5 + T x 2
19 x 2
25 x 2
3/8 x 2
1 x 2
30
120
15
30
Ver tabla
SPEZ-500YHA
3 x 10 + N + T x 2
3 x 2,5 + N + T
3 x 2,5 +T x 2
21 x 2
32 x 2
1/2 x 2
1 x 2
30
120
15
30
Ver tabla
NOTAS: Para longitudes superiores consultar las tablas de las pginas 30 y 31.
A+B+C+D
Unidad externa
En el momento
del envo (kg)
31- 40 m
41 - 50 m
51- 60 m
61 - 70 m
P - 200
5,8 Kg
No requiere carga
0,9 Kg
1,8 Kg
2,7 Kg
3,6 Kg
P - 250
7,1 Kg
adicional
1,2 Kg
2,4 Kg
3,6 Kg
4,8 Kg
26
15/6/10 16:28:07
Gama Industrial
INTERIORES
KIT DISTRIBUIDOR
PUHZ-P200YHA
100 + 100
MSDD-50WR-E
PUHZ-P250YHA
125 + 125
MSDD-50WR-E
Longitud de la tubera
MODELO
200 / 250
Diferencias de altura
Longitud mxima
Logitud total
Diferencias
entre distancias
Exterior - Interior
Interior - Interior
N de curvas
A + B: mx. 70 m
A + C: mx. 70 m
A + B + C: mx. 70 m
B - C: mx. 8 m
H: mx. 30 m
h: mx. 1 m
mx. 15
3x1
EXTERIORES
INTERIORES
KIT DISTRIBUIDOR
PUHZ-P200YHA
60 + 60 + 60
MSDT-111R-E
PUHZ-P250YHA
71 + 71 + 71
MSDT-111R-E
Longitud de la tubera
MODELO
Longitud mxima
200 / 250
Logitud total
A + B: mx. 70 m
A + C: mx. 70 m
A + D: mx. 70 m
Diferencias de altura
Diferencias
entre distancias
B - C: mx. 8 m
B - C: mx. 8 m
B - C: mx. 8 m
A + B + C + D: mx. 70 m
Exterior - Interior
Interior - Interior
N de curvas
H: mx. 30 m
h: mx. 1 m
mx. 15
4x1
EXTERIORES
INTERIORES
KIT DISTRIBUIDOR
PUHZ-P200YHA
50 + 50 + 50 + 50
MSDF-1111R-E
PUHZ-P250YHA
60 + 60 + 60 + 60
MSDF-1111R-E
Longitud de la tubera
MODELO
Longitud mxima
200 / 250
A + B: mx. 70 m
A + C: mx. 70 m
A + D: mx. 70 m
A + E: mx. 70 m
Logitud total
A + B + C + D + E: mx. 70 m
Diferencias de altura
Diferencias
entre distancias
B - C: mx. 8 m
B - D: mx. 8 m
B - E: mx. 8 m
C - D: mx. 8 m
C - E: mx. 8 m
D - E: mx. 8 m
Exterior - Interior
Interior - Interior
H: mx. 30 m
h: mx. 1 m
N de curvas
mx. 15m
NOTAS: Todas las series llevan incorporado de serie el control de condensacin. El precio de las combinaciones con Evaporadoras de la serie PLA incluyen el grill.
En el sistema COMPO las unidades interiores funcionarn siempre con un slo control remoto, simultneamente, y nunca de forma independiente. Se recomienda utilizar control remoto de pared.
CONTROL A
Conexionado de control y limitaciones de tubera frigorfica
IMPORTANTE: Siempre funcionarn las dos, tres o cuatro unidades interiores a la vez con un solo control remoto.
Bajo ningn concepto instale dos o tres controles remotos.
NOTA: Las unidades interiores se codifican automticamente.
Slo se alimentan elctricamente las unidades exteriores (en el caso de tener unidades interiores con resistencias elctricas de apoyo, stas tambin debern ser alimentadas elctricamente).
A+B+C+D
Unidad externa
En el momento
del envo (kg)
31- 40 m
41 - 50 m
51- 60 m
61 - 70 m
P - 200
5,8 Kg
No requiere carga
0,9 Kg
1,8 Kg
2,7 Kg
3,6 Kg
P - 250
7,1 Kg
adicional
1,2 Kg
2,4 Kg
3,6 Kg
4,8 Kg
27
15/6/10 16:28:09
Tecnologa
Replace
Datos
de Instalacin
Gama Industrial
Serie SEZ
MODELO
Caudales m3/h
Presiones disponibles (Pa)
Min
Med
Max
SEZ-KD25VA
330
420
540
5 / 15 / 35 / 50
SEZ-KD35VA
420
540
660
5 / 15 / 35 / 50
SEZ-KD50VA
600
750
900
5 / 15 / 35 / 50
SEZ-KD60VA
720
900
1080
5 / 15 / 35 / 50
SEZ-KD71VA
720
960
1200
5 / 15 / 35 / 50
Serie PEAD
Caudales m3/min
MODELO
Max
PEAD-RP35JA
10
14
35 / 50 / 70 / 100 / 150
PEAD-RP50JA
12
17
35 / 50 / 70 / 100 / 150
PEAD-RP60JA
14,5
21
35 / 50 / 70 / 100 / 150
PEAD-RP71JA
17,5
25
35 / 50 / 70 / 100 / 150
PEAD-RP100JA
24
34
35 / 50 / 70 / 100 / 150
PEAD-RP125JA
29,5
42
35 / 50 / 70 / 100 / 150
PEAD-RP140JA
32
46
35 / 50 / 70 / 100 / 150
Serie PEA
Caudales m3/h
MODELO
Min
Max
PEA-RP200GA
52
65
150
PEA-RP250GA
64
80
150
PEA-RP400GA
120
150
PEA-RP500GA
160
150
28
15/6/10 16:28:10
Datos de Instalacin
PUHZ-HW
230V
(monofsica)
PUHZ-HW
Air to Water
Diferencial
Placa FTC
I.C.P.
(Ver tabla)
400V
(trifsica)
I.C.P.
(Ver tabla)
Control Remoto
PAR-W21MAA
MODELO
Intensidad mxima
2
SECCIN A mm
SECCIN B mm
Tubera de agua
Salida
PUHZ-W50V
2x4+T
3 x 2,5 +T
13
16
Frio
Calor
PUHZ-W85V
2x6+T
3 x 2,5 +T
23
25
12,3
14,3
PUHZ-HW112Y
3x4+N+T
3 x 2,5 +T
13
20
21,5
25,8
PUHZ-HW140V
2 x 16 + T
3 x 2,5 +T
35
40
28,7
32,1
PUHZ-HW140Y
3x4+N+T
3 x 2,5 +T
13
20
35,8
40,1
SW2 Ajuste
Datos de operacin
1: ON / 0: OFF
SW2 Ajuste
Datos de operacin
1 2 3 4 5 6
Modo de funcionamiento cuando se produjo el error (Mode)
Error cdigo de la historia (1) [Ms recientes]
(Code)
Error cdigo de la historia (2)
(Code)
Error cdigo de la historia (3) [antiguo]
(Code)
Aplazado historial de errores (1)
(Code)
Aplazado historial de errores (2)
(Code)
Aplazado historial de errores (3)
(Code)
Temperatura de condensacin
[T63HS]
Temperatura del tubo de lquido
[TH6]
Frecuencia del compresor
(Hz)
Paso del ventilador
(Step)
Temperatura de la tubera de lquido
[TH3]
Temperatura de descarga
[TH4]
LEV-A pulsos de apertura
[LEV-A]
LEV-B pulsos de apertura
[LEV-B]
Temperatura ambiente
[TH7]
Temperatura de entrada de agua
[TH32]
Temperatura del disipador
[TH8]
Mximo calculado frecuencia
(Hz)
Sub enfriamiento
[SC]
Tiempo de operacin del compresor
(Min)
Solicitud de capacidad de paso
[QSTEP]
Recalentamiento de la descargar
[SHd]
Corriente del compresor
(A)
Capacidad de configuracin
(Code)
Compresor ON / OFF
(x100)
Compresor acumulado horas de funcionamiento (x10hours)
U9 historial de errores detalles de la ltima
(Code)
Compruebe suma
(Code)
/
/
/
/
/
[TH32]
[TH6]
[T63HS]
[TH7]
(Hz)
(Step)
[TH3]
[TH4]
[LEV-A]
[LEV-B]
[LEV-C]
[QSTEP]
[TH33]
[TH33]
[TH8]
[SHd]
(Hz)
(Min)
[SC]
(%)
(V)
(A)
(0.1A)
[ Tj]
0
0
1
1
1
1
1
0
0
0
0
1
0
0
0
1
1
0
0
1
0
0
1
1
0
0
0
0
0
1
1
0
1
0
1
0
0
1
1
1
1
1
0
0
0
0
1
0
0
0
1
1
1
1
1
0
0
0
0
0
1
1
1
0
1
1
1
0
0
1
1
1
0
0
0
1
0
0
1
0
0
0
0
1
0
1
1
1
1
1
1
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
1
1
1
0
1
1
1
1
0
0
1
0
1
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
1
1
1
2
1
1
1
0
0
1
1
1
1
1
1
1
0
0
0
0
0
1
1
0
0
1
1
0
1
0
0
1
1
3
0
1
1
0
0
1
1
1
1
0
0
0
1
1
0
0
0
0
1
1
1
1
0
1
0
1
1
0
0
4
0
1
1
0
0
1
1
1
1
0
0
0
1
1
0
0
0
0
1
1
1
1
0
1
0
1
1
0
0
5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
0
1
0
0
0
1
1: ON / 0: OFF
6
0
0
0
1
0
1
1
1
1
1
1
0
0
1
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
10ths
digit
1st
digit
29
15/6/10 16:28:11
Datos de Instalacin
Consumo
en amperios
Seccin recomendada en mm2 para 230V monofsico y las siguientes longitudes de cable
10 m
20 m
30 m
40 m
50 m
60 m
70 m
80 m
90 m
100 m
1,0
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
1,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,0
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
3,0
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
3,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
4,0
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
4,0
4,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
5,0
2,5
2,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
5,5
2,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
4,0
6,0
2,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
4,0
6,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
4,0
4,0
7,0
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
4,0
6,0
7,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
4,0
6,0
8,0
2,5
2,5
2,5
2,5
4,0
4,0
4,0
4,0
6,0
6,0
8,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
6,0
6,0
6,0
9,0
2,5
2,5
2,5
2,5
4,0
4,0
4,0
6,0
6,0
6,0
9,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
6,0
6,0
6,0
10,0
4,0
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
6,0
10,5
4,0
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
6,0
11,0
4,0
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
11,5
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
6,0
10,0
12,0
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
12,5
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
13,0
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
13,5
4,0
4,0
4,0
4,0
4,0
6,0
6,0
10,0
10,0
10,0
14,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
10,0
14,5
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
10,0
15,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
10,0
15,5
4,0
4,0
4,0
4,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
4,0
4,0
4,0
4,0
6,0
6,0
10,0
10,0
10,0
10,0
16,5
4,0
4,0
4,0
4,0
6,0
6,0
10,0
10,0
10,0
10,0
17,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
17,5
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
18,0
4,0
4,0
4,0
6,0
6,0
10,0
10,0
10,0
10,0
10,0
18,5
6,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
10,0
19,0
6,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
19,5
6,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
20,0
6,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
20,5
6,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
21,0
6,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
16,0
16,0
21,5
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
16,0
22,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
16,0
22,5
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
16,0
23,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
16,0
23,5
10,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
24,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
24,5
10,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
25,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
25,5
10,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
26,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
26,5
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
27,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
27,5
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
28,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
28,5
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
29,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
29,5
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
30,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
30
15/6/10 16:28:16
Gama Industrial
Consumo
en amperios
Seccin recomendada en mm2 para 400 trifsico y las siguientes longitudes de cable
10 m
20 m
30 m
40 m
50 m
60 m
70 m
80 m
90 m
100 m
1,0
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
1,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,0
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
3,0
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
3,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
4,0
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
4,0
4,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
5,0
2,5
2,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
5,5
2,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
4,0
6,0
2,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
4,0
6,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
4,0
4,0
7,0
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
4,0
6,0
7,5
2,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
6,0
6,0
8,0
2,5
2,5
2,5
2,5
4,0
4,0
4,0
4,0
6,0
6,0
8,5
2,5
2,5
2,5
2,5
4,0
4,0
4,0
6,0
6,0
6,0
9,0
2,5
2,5
2,5
2,5
4,0
4,0
4,0
6,0
6,0
6,0
9,5
2,5
2,5
2,5
4,0
4,0
4,0
6,0
6,0
6,0
6,0
10,0
2,5
2,5
2,5
4,0
4,0
4,0
6,0
6,0
6,0
6,0
10,5
4,0
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
11,0
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
6,0
10,0
11,5
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
12,0
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
12,5
4,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
13,0
4,0
4,0
4,0
4,0
4,0
6,0
6,0
10,0
10,0
10,0
13,5
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
10,0
14,0
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
10,0
14,5
4,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
10,0
15,0
4,0
4,0
4,0
4,0
6,0
6,0
10,0
10,0
10,0
10,0
15,5
4,0
4,0
4,0
4,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
4,0
4,0
4,0
4,0
6,0
6,0
10,0
10,0
10,0
10,0
16,5
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
17,0
4,0
4,0
4,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
17,5
4,0
4,0
4,0
6,0
6,0
10,0
10,0
10,0
10,0
10,0
18,0
4,0
4,0
4,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
18,5
6,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
19,0
6,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
19,5
6,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
20,0
6,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
16,0
16,0
20,5
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
16,0
21,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
16,0
21,5
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
16,0
22,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
16,0
22,5
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
16,0
23,0
6,0
6,0
6,0
6,0
10,0
10,0
10,0
10,0
16,0
16,0
23,5
6,0
6,0
6,0
6,0
10,0
10,0
10,0
16,0
16,0
16,0
24,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
24,5
10,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
25,0
10,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
25,5
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
26,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
26,5
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
27,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
27,5
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
28,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
28,5
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
29,0
10,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
29,5
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
16,0
30,0
10,0
10,0
10,0
10,0
10,0
16,0
16,0
16,0
16,0
16,0
31
15/6/10 16:28:17
Cdigos de inspeccin
PARA MS INFORMACIN:
Departamento tcnico 902 400 744
www.mitsubishielectric.es
GAMA DOMSTICA
EJEMPLO:
Escriba dom seguido de un espacio e indique los parpadeos del piloto Operation Indicator.
Gama
Cuando el led Operation Indicator
parpadea 5 veces.
- Si el parpadeo es continuo indquelo
con el smbolo *.
Cuando el led Operation
Indicator parpadea
continuamente.
- Si la unidad es Inverter aada una i antes
del nmero de parpadeos.
Cuando el led Operation
Indicator parpadea 3 veces
en una unidad Inverter.
32
15/6/10 16:28:18
GAMA COMERCIAL
EJEMPLO:
CON CDIGO DE ERROR DE 2 DGITOS.
Escriba mr seguido de un espacio y el cdigo
de error.
N DE PITIDOS DE LA UNIDAD.
Escriba mr seguido de un espacio, el smbolo
# y el nmero de pitidos que emita la unidad
interior. (Para unidades con control inalmbrico)
Cualquiera de estos
mensajes representan:
1 parpadeo verde
y 3 rojos.
CDIGO DE 4 DGITOS.
Escriba mr seguido de un espacio y el cdigo
de error de 4 dgitos.
GAMA CITYMULTI
EJEMPLO:
Escriba city seguido de un espacio y el nmero de cuatro dgitos que indica el error en este
tipo de unidades.
Gama
33
15/6/10 16:28:18
Cdigos de inspeccin
Punto de anomala
Cableado incorrecto
Seal serie
de comunicacin
Sntoma
La unidad exterior
no funciona
Mtodo de deteccin
Punto de comprobacin
Sonda Bateria
La unidad exterior
no funciona
Deteccin de un cortocircuito o circuito abierto en la resistencia de la sonda de temperatura ambiente / serpentn interior cada 8 segundos durante el funcionamiento
Sonda Ambiente
CN121
Sistema de potencia
exterior
Sonda unidad
exterior
La unidad exterior
no funciona
La unidad exterior
no funciona
Cuando ocurre 3 veces consecutivas que el compresor se detiene por error de proteccin de sobrecorriente de arranque dentro de 1 minuto despus
del comienzo.
Cuando no se pueden leer correctamente los datos en la memoria no voltil de la placa electrnica
exterior.
componentes.
Consulte el servicio manual OB331 o OB319.
34
15/6/10 16:28:18
Gama Domstica
1. Diagrama del flujo del modo de revisin de errores de las unidades interiores/exteriores
Procedimiento operacional
La causa del error no puede ser hallada porque el error no vuelve a ocurrir.
1. Mientras presiona el botn OPERATION SELECT
y el TOO COOL en el control remoto al mismo tiempo,
presione el botn RESET.
2. Primero, suelte el botn RESET, y luego suelte los otros
dos botones despus de 3 segundos que se vean todos
los LCD del display encendidos.
Encienda la Alimentacin.
1 Mientras mantiene presionados simultaneamente los botones
OPERATION SELECT y TOO COOL, presine el botn RESET.
2 Primero, suelte el botn RESET.
Luego suelte los otros dos botones a partir de que se enciendan durante
3 segundos todos los LCD del display del control remoto .
*1
Presione el botn OPERATE/STOP(ON/OFF) del control remoto (se exhibir la
temperatura configurada)
Con el control remoto apuntado hacia la unidad interior, presione el botn TOO COOL
(muy fresco) o el TOO WARM (muy clido) para ajustar la temperatura a 24 C)
No
(OFF)
Si (Parpadeos)
Si
No
Nota 1. Asegrese de liberar la funcin de modo de revisin de errores una vez que est configurada,
de otro modo la unidad no podr funcionar correctamente.
2. Si no se borra la condicin de anormal de la memoria, se mantendr memorizada la ltima
condicin de anormal.
*2 Patrn de parpadeo cuando la unidad interior funciona de modo anormal:
*2 Patrn de parpadeo cuando la unidad interior funciona de modo anormal:
35
15/6/10 16:28:19
Cdigos de inspeccin
TABLA DEL MODO DE FALLO DE LA UNIDAD INTERIOR
Luz izquierda del
INDICADOR de FUNCIN
Punto anormal
(Modo de fallo)
Mtodo de deteccin
No iluminado
Normal
Parpadeo1 vez
cada 0.5-segundos
Parpadeo 2 veces
2.5-segundos OFF
Parpadeo 3 veces
2.5-segundos OFF
Parpadeo11 veces
2.5-segundosOFF
Parpadeo 12 veces
2.5-segundos OFF
NOTAS: Los patrones de parpadeo de este modo difieren de aquellos de la Tabla de control de la Reparacin de averas
No
(apagado)
Si
(Parpadea)
2.5-segundos APAGADO
3-segundos ENCENDIDO
Parpadea a intervalos de
2.5-segundos APAGADO
0.5 segundos
3-segundos ENCENDIDO
Parpadea a intervalos de
0.5 segundos
ENCENDIDO
APAGADO
Sin pitidos
Ciclo repetido
Sin pitidos
Ciclo repetido
Pitidos
Pitidos
Ciclo repetido
36
15/6/10 16:28:19
Gama Domstica
Parpadea 2 veces
Parpadea 3 veces
Punto anormal
(Modo de fallo)
Ninguno (Normal)
Parpadea 5 veces
Condicin
Correspondencia
LED1
LED2
Encendido
Encendido
Termistor de temperatura de
descarga
Encendido
1 vez
Termistor de
descongelamiento
Encendido
1 vez
Encendido
2 veces
Encendido
3 veces
Encendido
4 veces
9 veces
Termistor de temperatura
ambiente
Termistor de temperatura
de aleta
Termistor de temperatura
placa P.C.
Parpadea 4 veces
Indicacin LED
(PlacaP.C.exterior)
Sobrecorriente
Temperatura de descarga
1 vez
Encendido
Se apaga
Encendido
Presin alta
Encendido
Encendido
Temperatura de aleta
3 veces
Se apaga
4 veces
Se apaga
Parpadea 8 veces
Encendido
Encendido
Cuando la falla ocurre 3 veces conse-cutivas dentro de los 30 segundos des-pus del
arranque del ventilador.
Parpadea 9 veces
Datos de memoria no
voltil
Encendido
5 veces
Parpadea 10 veces
Temperatura de
descarga
Encendido
Encendido
Parpadea 6 veces
Parpadea 7 veces
Encendido
6 veces
Sensor de Corriente
Encendido
7 veces
Parpadea 11 veces
Circuito de deteccin de
cruce por cero
5 veces
Se apaga
Converter
5 veces
Se apaga
5 veces
Se apaga
6 veces
Se apaga
Cuando la tensin de la barra onductora excede de 400V o cae a 50V o menos durante
el funcionamiento del compresor.
37
15/6/10 16:28:19
Cdigos de inspeccin
Lista de cdigos de errores.
El cdigo de error se mostrar bajo las siguientes condiciones:
Si se produce un error de comunicacin, el cdigo de error mostrado en la pantalla del mando a distancia puede no coincidir con las
indicaciones de los LEDS de la placa electrnica de la unidad exterior (o estar en blanco).
Se produce un sonido BIP durante la prueba de errores con el mando a distancia inalmbrico.
PAR-20 PAC-SK52
MANDO INALMBRICO
LED1 (Verde)
LED2 (Rojo)
Ver Pantalla
Ver Pantalla
4 parpadeos
1 parpadeo
P1
1 BIP
5101
Interior
P2
2 BIPS
5102
Interior
P9
3 BIPS
5103
Interior
P4
4 BIPS
2503
Interior
P5
5 BIPS
2500, 2502
Interior
3 parpadeos
P6
6 BIPS
1503, 1504
Interior
4 parpadeos
P8
8 BIPS
Interior
2 parpadeos
1110
UNIDAD A
INSPECCIONAR
DETALLE DE ERROR
2. Deteccin de cdigos de error de transmisin entre el MANDO A DISTANCIA y la UNIDAD INTERIOR EXTERIOR
DETECCIN CDIGOS DE ERROR LEDS U. EXT.
PAR-20 PAC-SK52
MANDO INALMBRICO
Ver Pantalla
Ver Pantalla
UNIDAD A
INSPECCIONAR
DETALLE DE ERROR
LED1 (Verde)
LED2 (Rojo)
2 parpadeos
1 parpadeo
EA
2 BIPS cortos x4
6844
Exterior
2 parpadeos
1 parpadeo
EB
2 BIPS cortos x4
6845
Exterior
2 parpadeos
1 parpadeo
EC
2 BIPS cortos x4
6846
Exterior
2 parpadeos
2 parpadeos
E6
3 BIPS
6840
Interior
2 parpadeos
2 parpadeos
E7
3 BIPS
6841
Interior
2 parpadeos
1 parpadeo
E8
2 BIPS cortos x3
6840
Exterior
2 parpadeos
1 parpadeo
E9
2 BIPS cortos x3
6841
Exterior
2 parpadeos
3 parpadeos
E0
sin salida
No display
Mando a distania
2 parpadeos
3 parpadeos
E3
sin salida
No display
Mando a distania
2 parpadeos
2 parpadeos
E4
9 BIPS
6831
Interior
2 parpadeos
2 parpadeos
E5
9 BIPS
6832
Interior
2 parpadeos
4 parpadeos
EF
10 BIPS
6607
Exterior
2 parpadeos
1 parpadeo
6608
Exterior
2 parpadeos
5 parpadeos
2 BIPS cortos x4
0403
Exterior
ED
PAR-20 PAC-SK52
MANDO INALMBRICO
Ver Pantalla
Ver Pantalla
UNIDAD A
INSPECCIONAR
DETALLE DE ERROR
LED1 (Verde)
LED2 (Rojo)
2 parpadeos
5 parpadeos
A0
2 BIPS cortos x4
6600
Exterior
2 parpadeos
5 parpadeos
A2
2 BIPS cortos x4
6602
Exterior
2 parpadeos
5 parpadeos
A3
2 BIPS cortos x4
6603
Exterior
2 parpadeos
5 parpadeos
A6
2 BIPS cortos x4
6606
Exterior
2 parpadeos
5 parpadeos
A7
2 BIPS cortos x4
6607
Exterior
2 parpadeos
5 parpadeos
A8
2 BIPS cortos x4
6608
Exterior
38
15/6/10 16:28:20
Gama Industrial
4. Deteccin de cdigos de error de la UNIDAD EXTERIOR
DETECCIN CDIGOS DE ERROR LEDS U. EXT.
LED1 (Verde)
1 parpadeo
LED2 (Rojo)
1 parpadeo
2 parpadeos
CDIGO
DE ERROR
F1 (4103)
Deteccin de antifase
F2 (4102)
F3 (5202)
F4 (4124)
F9 (4124)
Conector 2 o ms abierto
Conector 2 o ms abierto
FA (4108)
3 parpadeos
F7 (4118)
F8
3 parpadeos
1 parpadeo
2 parpadeos
MTODO DE INSPECCIN
ERROR
U2 (1102)
U2 (1108)
U7 (1520)
Anomalia de supercalentamiento
debida a la baja temperatura
de descarga
U1 (1302)
U1
UE (1509)
Detectado por CT
Slo PU(H)-P125,
P140YGA
UL (1300)
3 parpadeos
UD (1504)
Proteccin de sobrecalentamiento
4 parpadeos
U6 (4101)
UA (4101)
UF (4100)
UF (4100)
Conmutacin de compresor de exceso Deteccin de corriente bloqueada durante el funcionamiento del compresor
de corriente (bloqueo de funcionamiento)
UH (5300)
UP (4210)
U3 (5104)
5 parpadeos
U4 (TH3:5105) Error
(TH6:5107)
(TH7:5106)/(TH8:5110)
6 parpadeos
7 parpadeos
COMENTARIOS
U5 (4230)
U9 (4220)
de sonda exterior
Detectado por CT
Slo PU(H)-P125,
P140YGA
Slo PU(H)-P YGA
Detectado por CT
Funcin: 33 Kg/cm2
Reinicio: 26 Kg/cm2
Anomala en el voltaje
84O C
RP60/71
77O C
RP100/125/140V
85O C
RP100/125/140Y
95O C
39
15/6/10 16:28:20
RESULTADO
COMPRA
U/E
U/I
Horas
Veces
A
Refrigeracin
Refrigeracin
6) Temperatura exterior
Refrigeracin
Refrigeracin
Refrigeracin
Calefaccin
C
C
Calefaccin
C
Calefaccin
C
C
C
Calefaccin
Calefaccin
C
Horas
PAR-21MAA
2. PROCEDIMIENTO
MENU
COOL
STABLE MODE
HEAT
STABLLE MODE
STABLE
MODE CONCEL
COMP ON
x 10 HOURS
COMP ON
CURRENT (A)
5 Temp. de descarga
OUTDOOR UNIT
H-EXC TEMP
OUTDOOR UNIT
OUTLET TEMP
6 Temp. exterior
OUTDOOR UNIT
OUTLET TEMP
3 Corriente de operacin
COMP ON
x 100 TIMES
INDOOR UNIT
INLET TEMP
Repita los pasos (5) - (7) para verificar los respectivos datos.
40
15/6/10 16:28:20
Gama Industrial
3. ANLISIS DE DATOS
Con los datos de la tabla que rellen en la pgina anterior, efecte las siguientes operaciones y traze los datos en el grfico para juzgar las condiciones de funcionamiento.
RENGLN
CLASIFICACIN
REFRIGERACIN
(C)
(C)
5) Temp. de descarga
(C)
(C)
5) Temp. de descarga
DIFERENCIA DE
TEMPERATURA
REFRIGERACIN
CALEFACCIN
(C)
(C)
45
45
40
Verificacin C
35
30
30
25
20
25
Verificacin B
Normal
20
Normal
15
15
10
10
Verificacin A
5
0
Verificacin C
40
35
RESULTADO
CALEFACCIN
10
20
30
5
Verificacin A
5
40
50
4
60
70
80
(C)
10
20
30
40
50
8
60
70
80
(C)
RESULTADO
REFRIGERACIN
Normal
CALEFACCIN
Operacin normal
Verificacin A
Verificacin B
Refrigerante insuficiente
Verificacin C
41
15/6/10 16:28:21
Monitor
Ejemplo:
Cdigo requerido 04
Temperatura de descarga 69
Direccin de refrigerante: 00
A
D
B
(7)
(3)
(5)
(1)
(2)(6)
(4)
B: Direccin de refrigerante
C: rea de display de datos
D: rea de display de cdigo de requerimiento
(1) Presione el botn TEST durante tres segundos de modo que aparezca en la pantalla (Maintenace monitor) (en A).
(2) Presione el botn CHECK durante tres segundos para pasar a (Monitor de mantenimiento)
Nota. Si no es posible pasar a (Monitor de mantenimiento) durante el requerimiento de datos en el modo mantenimiento
(ej. mientras parpadea ----), dado que ningn botn es operativo.
Operando el monitor de inspeccin de servicio.
Aparece en la pantalla (en D) cuando (Monitor de mantenimiento) est activado.
(El display (en D) ahora nos permite configurar un N de cdigo)
(3) Presione los botones [ TEMP] (
[ Pantalla B]
00
01
.....
15
42
15/6/10 16:28:21
Contenido requerido
Descripcin
(Rango de display)
Unidad
Estado de operacin
0 / 50
0 / 9999
10 horas
0 / 9999
100 veces
3 / 217
4
5
-40 / 90
-40 / 90
-39 / 88
-39 / 88
10
-40 / 200
Observaciones
11
12
0 / 255
13
0 / 130
16
Compresor-Frecuencia de operacin
0 / 255
Hz
17
0 / 255
Hz
18
0 / 10
Paso
19
0 / 9999
rpm
20
0 / 9999
rpm
22
0 / 500
Pulsos
23
0 / 500
Pulsos
14
15
21
24
25
Corriente primaria
0 / 50
26
180 / 370
29
0/4
Unidades
30
17 / 30
31
8 / 39
32
8 / 39
33
8 / 39
34
8 / 39
35
8 / 39
-39 / 88
27
28
36
37
43
15/6/10 16:28:22
Contenido requerido
Descripcin
(Rango de display)
Unidad
38
-39 / 88
39
-39 / 88
40
-39 / 88
42
-39 / 88
43
-39 / 88
44
-39 / 88
45
-39 / 88
48
0 / 999
Minutos
49
0 / 120
Minutos
50
51
52
53
54
55
Observaciones
41
Se exhibe 0 si la unidad de destino no est
presente
46
47
56
57
58
59
Capacidad de demanda de seal de transmisin
0 - 255
61
62
70
Unidad exterior-Display de
configuracin de capacidad
71
Unidad exterior-Informacin
de configuracin
73
Unidad exterior-Informacin de
configuracin de SW1
74
Unidad exterior-Informacin de
configuracin de SW2
76
Unidad exterior-Informacin de
configuracin de SW4
77
Unidad exterior-Informacin de
configuracin de SW5
60
63
64
65
66
67
69
72
75
44
15/6/10 16:28:22
Cdigo de
requerimiento
Contenido requerido
Descripcin
(Rango de display)
Unidad
78
Unidad exterior-Informacin de
configuracin de SW6
79
Unidad exterior-Informacin de
configuracin de SW7
80
Unidad exterior-Informacin de
configuracin de SW8
81
Unidad exterior-Informacin de
configuracin de SW9
82
Unidad exterior-Informacin de
configuracin de SW10
Observaciones
83
Conexin de adaptador M-NET
(presencia/ausencia)
84
0000: No conectado
0001: Conectado
0000: No lavado
0001: Lavado
85
86
87
88
89
90
Versin
91
100
Unidad exterior-Historia de
postergacin de error 1 (ltimo)
Cdigo
101
Unidad exterior-Historia de
postergacin de error 2 (penltimo)
Cdigo
102
Unidad exterior-Historia de
postergacin de error 2 (antepenltimo)
Cdigo
103
Cdigo
104
Cdigo
105
Cdigo
106
107
108
Compresor-Corriente de operacin en el
momento del error
0 - 50
109
Compresor-Tiempo de operacin
acumulado en el momento del error
0 - 9999
10 horas
92
93
94
95
96
97
98
99
3 C TH3
6 C TH6
7 C TH7
8 C TH8
0 C Sin error de termistor
Nmero de
sensor
45
15/6/10 16:28:23
Contenido requerido
Descripcin
(Rango de display)
Unidad
110
0 - 9999
100 veces
111
Temperatura de descarga en el
momento del error
3 - 217
112
-40 / 90
113
-40 / 90
114
-39 / 88
116
-39 / 88
117
-40 / 200
118
0 / 255
119
0 / 130
120
Compresor-Frecuencia de operacin en el
momento del error
0 / 255
Hz
0 / 10
Paso
Observaciones
115
121
122
0 / 9999
rpm
123
0 / 9999
rpm
125
0 / 500
Pulsos
126
0 / 500
Pulsos
0 / 999
Minutos
124
127
128
129
130
131
132
-39 / 88
133
-39 / 88
134
-39 / 88
135
136
137
138
139
140
~
46
15/6/10 16:28:23
Cdigo de
requerimiento
Contenido requerido
Descripcin
(Rango de display)
Unidad
150
-39 / 88
151
-39 / 88
152
-39 / 88
154
0 / 9999
1 hora
155
0 / 9999
10 horas
157
158
159
162
Unidad interior-Informacin de
configuracin de modelo
163
Unidad interior-Informacin de
configuracin de capacidad
164
Indefinido
165
166
Indefinido
Versin
Observaciones
146
147
148
149
153
156
160
161
167
~
189
190
191
192
~
764
765
766
767
47
15/6/10 16:28:23
( Intervalo de 1 segundo )
SW2
ON
1 2 3 4 5 6
(Configuracin inicial)
LED1
(Encendido)
Display
Precalentando
al compresor
Compresor
Vlvula de 4 vas
Vlvula solenoide
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Display
Unidad inspeccionada
APAGADO / VENTILADOR
REFRIGERACIN / SECADO *
CALEFACCIN
DESESCARCHADO
48
15/6/10 16:28:23
Gama Industrial
Unidad inspeccionada
Unidad exterior
Unidad Interior 1
Unidad interior 2
Unidad interior 3
Display
U1
U2
U3
U4
U5
U6
U7
U8
UD
Proteccin de sobretemperatura
UF
UH
UL
UP
P1~P8
A0~A7
Display
F5
E8
E9
EA
EB
EC
E0~E7
49
15/6/10 16:28:24
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
3-217
(Cuando el termistor de descarga detecta 100 o superior, se
exhiben en forma alternada las centenas decenas y unidades)
EJEMPLO: Cuando 105C; 0,5 seg. 0,5 seg. 2 seg.
0-9999
(Cuando son 100 o ms, se exhiben en forma alternada las
centenas, decenas y unidades)
EJEMPLO: Cuando 2450 veces (245 x 10 horas )
0,5 seg. 0,5 seg. 2 seg.
Corriente de operacin
del compresor
0 a 50
0-255
(Cuando es 100 Hz o mas, se exhiben en forma alternada las
centenas, decenas y unidades)
EJEMPLO: Cuando 125Hz; 0,5 seg. 0,5 seg. 2 seg.
ON
1 2 3 4 5 6
Hz
25
0-480
(Cuando es 100 pulsos o mas, se exhiben en forma alternada
las centenas, decenas y unidades)
EJEMPLO: Cuando 150 pulsos; 0,5 seg. 0,5 seg. 2 seg.
10 horas
45
0~50
* omita las cifras despus de la fraccin decimal
Frecuencia de operacin
del compresor
0 a 225
100 veces
25
ON
1 2 3 4 5 6
paso
0-9999
(Cuando la cantidad de veces es 100 o superior, se exhiben
en forma alternada las centenas, decenas y unidades)
EJEMPLO: Cuando 42500 veces (425 x 100 veces )
0,5 seg. 0,5 seg. 2 seg.
05
0~10
ON
1 2 3 4 5 6
10
ON
1 2 3 4 5 6
UNIDAD
Pulso
50
Exhibe el cdigo
50
15/6/10 16:28:24
Gama Industrial
CONFIGURACIN DE SW2
UNIDAD
ON
(SW2)
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
-40 a 90
(Cuando el termistor de serpentina detecta 0 o inferior, se
exhiben en forma alternada - y la temperatura)
EJEMPLO: Cuando -15C; 0,5 seg. 0,5 seg. 2 seg.
ON
1 2 3 4 5 6
Exhibe el cdigo
ON
1 2 3 4 5 6
15
Temperatura del compresor (TH4) o temperatura de descarga (TH4) cuando ocurre el error
3 a 217
3-217
(Cuando el termistor de descarga detecta 100 o superior, se
exhiben en forma alternada las centenas decenas y unidades)
EJEMPLO: Cuando 130C; 0,5 seg. 0,5 seg. 2 seg.
30
0~20
Exhibe
el
cdigo
Exhibe
el
cdigo
Tiempo de termostato en ON
0~999
0~999
(Cuando son 100 minutos o ms, se exhiben en forma alternada las centenas, decenas y unidades)
EJEMPLO: Cuando 245 minutos
0,5 seg. 0,5 seg. 2 seg.
1 2 3 4 5 6
45
0-120
(Cuando son 100 minutos o ms, se exhiben en forma alternada las centenas, decenas y unidades)
EJEMPLO: Cuando 105 minutos
0,5 seg. 0,5 seg. 2 seg.
Minuto
Minuto
05
51
15/6/10 16:28:24
UNIDAD
0~4
(Se exhibe la cantidad de unidades interiores
conectadas)
ON
Unidad
ON
CAPACIDAD
CDIGO
CAPACIDAD
CDIGO
RP35VA
RP100V/Y
20
RP50VA
10
RP125V/Y
25
RP60VA
11
RP140V/Y
28
RP71VA
14
Exhibe
el
cdigo
ON
DETALLES DE
CONFIGURACIN
HP
Slo refrigeracin
0: HP
1: Slo refrigeracin
Monofsico /
Trifsico
0: Monofsico
2: Trifsico
1 2 3 4 5 6
Exhibe
el
cdigo
Las unidades
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
DETALLES DE
CONFIGURACIN
Interruptor de
desescarchado
0: Normal
1: Para alta humedad
- 39~88
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura).
- 39~88
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura).
- 39~88
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura).
- 39~88
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura).
8~39
52
15/6/10 16:28:25
Gama Industrial
CONFIGURACIN DE SW2
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
17~30
- 39~88
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura).
- 39~88
(Cuando la temperatura es 0C o inferior, se exhiben en
forma alterna - y la temperatura).
- 40~200
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura).
(Cuando el termistor detecta 100C o superior, se exhiben en
forma alternada las centenas, decenas y unidades).
0~255
(Cuando la temperatura es 100C o superior, se exhiben en
forma alternada las centenas, decenas y unidades).
0~130
(Cuando la temperatura es 100C o superior, se exhiben en
forma alternada las centenas, decenas y unidades).
0~500
(Cuando la temperatura es 100C o superior, se exhiben en
forma alternada las centenas, decenas y unidades).
0,1 A
0-480
(Cuando es 100 Hz o superior, se exhiben en forma alternada
las centenas, decenas y unidades).
Pulso
0~255
(Cuando es 100 Hz o superior, se exhiben en forma alternada
las centenas, decenas y unidades).
Hz
180~370
(Cuando es 100 V o superior, se exhiben en forma alternada
las centenas, decenas y unidades).
Refrigeracin = TH4-TH6
Calefaccin = TH4-TH5
Sub refrigeracin. SC
0~130
Refrigeracin = TH6-TH3
Calefaccin = TH5-TH4
ON
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
UNIDAD
53
15/6/10 16:28:25
Tecnologa de
Replace
Extraccin
datos con PAC-SK52
CONFIGURACIN DE SW2
ON
1 2 3 4 5 6
Ahorro de capacidad
0~255
Cuando el acondicionador de aire es conectado
al M-NET y se demanda el modo de ahorro de
capacidad, se exhibe 0~100.
0~100
(Cuando la capacidad es 100%, se exhiben en forma alternada las centenas, decenas y unidades).
EJEMPLO: Cuando 100%; 0,5 seg. 0,5 seg. 2seg.
Exhibe
el
cdigo
Exhibe
el
cdigo
Exhibe
el
cdigo
Exhibe
el
cdigo
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
0~255
(Cuando es 100 Hz o superior, se exhiben en forma alternada
las centenas, decenas y unidades)
EJEMPLO: Cuando 125Hz; 0,5 seg. 0,5 seg. 2 seg.
ON
Frecuencia de operacin al ocurrir el error
0~255
1 2 3 4 5 6
ON
00
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
UNIDAD
Hz
25
0~10
Pasos
- 39~88
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura ).
1 2 3 4 5 6
ON
Temperatura de la tubera externa (TH33)
-39~88
1 2 3 4 5 6
54
15/6/10 16:28:26
Gama Industrial
CONFIGURACIN DE SW2
ON
1 2 3 4 5 6
0~480
(Cuando es 100 pulsos o ms, se exhiben en forma alternadas centenas, decenas y unidades)
Pulso de apertura de la VEL-A al ocurrir el error EJEMPLO: Cuando 130 pulsos;
0~480
0,5 seg. 0,5 seg. 2 seg.
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
UNIDAD
Pulsos
30
8~39
- 39~88
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura).
Temperatura de tubera de lquido interior (TH2)
EJEMPLO: Cuando -15C;
al ocurrir el error
0,5 seg. 0,5 seg. 2 seg.
-39 a 88
15
- 39~88
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura).
EJEMPLO: Cuando -15C;
0,5 seg. 0,5 seg. 2 seg.
15
- 39~88
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura).
EJEMPLO: Cuando -15C;
0,5 seg. 0,5 seg. 2 seg.
15
- 39~88
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura).
EJEMPLO: Cuando -15C;
0,5 seg. 0,5 seg. 2 seg.
15
-40~200
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura).
(Cuando la temperatura es 100C o superior, se exhiben en
forma alternadas centenas, decenas y unidades).
55
15/6/10 16:28:26
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
UNIDAD
0~255
(Cuando la temperatura es 100C o superior, se exhiben en
forma alternada las centenas, decenas y unidades).
EJEMPLO: Cuando 105C
0,5 seg. 0,5 seg. 2 seg.
50
0~130
(Cuando la temperatura es 100C o superior, se exhiben en
forma alternada las centenas, decenas y unidades).
EJEMPLO: Cuando 105C;
0,5 seg. 0,5 seg. 2 seg.
Refrigeracin = TH6-TH3
Calefaccin = TH5-TH4
15
0~130
(Cuando es 100 minutos o superior, se exhiben en forma
alternada las centenas, decenas y unidades).
EJEMPLO: Cuando 415 minutos;
0,5 seg. 0,5 seg. 2 seg.
Minuto
15
- 39 ~88
(Cuando la temperatura es 0C o inferior, se exhiben en forma
alterna - y la temperatura ).
- 39 ~88
(Cuando la temperatura es 0C o inferior, se exhiben en
forma alterna - y la temperatura ).
Operacin de reemplazo
* Si la operacin de reemplazo se conduce por
este mismo, se exhibir 1.
Si el tiempo de la operacin de reemplazo es
menor a las 2 horas, se exhibir 0.
1: Conducido
0: No an.
ON
Detalle de error suspensivo U9
1 2 3 4 5 6
DESCRIPCIN
CDIGO
CAPACIDAD
Normal
00
Error de sobretensin
Tablero de
alimentacin
01
Tablero
controlador
02
Tablero
controlador
04
Tablero de
alimentacin
08
Tablero de
alimentacin
10
Verifique el
cableado de
CNAF
Defecto ACTM
/ P.B.
20
Cdigo
del
display
56
15/6/10 16:28:26
Configuracin de funciones
Gama Industrial
Fallo de potencia,
recuperacin auto
Deteccin de
temperatura interior
*1
Conectividad
LOSSNAY
Modo
N
Configuraciones
Funcin
OFF
: Conf. inicial
(directo de fbrica)
Conf.
N
Observaciones
1
01
ON
02
No lo soporta
03
240V
Temperatura
preven. escarcha
2 (Normal)
Control del
humidificador
Cambio control
antiescarcha
Estndar
Ajuste filtracin de
refrigerante (%)
2
3
1
04
220V, 230V
La configuracin se
aplica a todas las
unidades en el mismo
sistema refrigerante
1
15
2
1
16
2
1
17
2
1
21
OUTDOOR
OUTDOOR
Temperatura
interior (ta) =
INDOOR A
REMOTE
(MAIN) C
N1
N2
N3
Conf.
Inicial
INDOOR B
REMOTE
(SUB) D
INDOOR A
INDOOR B
REMOTE
(MAIN) C
REMOTE
(SUB) D
OUTDOOR
OUTDOOR
INDOOR B
INDOOR A
REMOTE
(MAIN) C
REMOTE
(SUB) D
REMOTE
(MAIN) C
ta = (A+B) / 2
ta = A
ta = A
ta = A
ta = B
ta = A
ta = A
ta = C
ta = C
ta = C
ta = C
ta = (A+B) / 2
57
15/6/10 16:28:27
Configuracin de funciones
CONFIGURACIN DE FUNCIN DE LA UNIDAD MEDIANTE MANDO A DISTANCIA
(2) Funciones disponibles al ajustar el nmero de la unidad a 01-03 o AL (07 en el caso de un mando a distancia inalmbrico).
Al ajustar las funciones para una unidad interior en un sistema independiente, defina el nmero de unidad en 01 remitindose a la configuracin 4 el nmero de unidad interior del Procedimiento Operativo.
Al ejecutar las funciones para un sistema de unidades interiores simultneas Twin Triple, ajuste el nmero de unidad de 01 a 03 para cada
unidad exterior en caso de elegir distintas funciones para cada unidad remitindose a la configuracin 4 el nmero de unidad interior del
Procedimiento Operativo.
Cuando seleccione las mismas funciones para un sistema de unidades interiores simultneas Twin Triple, defina la direccin del refrigerante
en AL (07 en el caso del control remoto inalmbrico) remitindose a la configuracin 4 el n de unidad interior del Procedimiento Operativo.
Configuraciones
Funcin
Conf
N
100h
Signo de filtro
2500h
3 direcciones
10
1
11
2
3
Desactivado
12
Activado
Conf. veleta n2
13
14
No dispon.
Caudal aire onda
Disponible
23
2
1
24
No disponible
PCA-HA
PKA-HAL
PKA-KAL
1
25
Parada
27
Parada
PSA-GA
De pie
Extra bajo
Conf. veleta n1
Disponible
Montado en pared
09
PCA-KA
PEA-GA
1
08
2 direcciones
Giro
PLA-BA
4 direcciones
Suspendido en techo
07
Silencioso
Caudal de aire
Estndar
(Velocidad ventilador)
Techo alto
Configuracin
de veleta
Oculto
en techo
N de salidas de aire
Cinta en 4
vas
Deteccin
Disponible
anormalidad de temp.
No Disponible
conducto (P8)
28
2
*1. PKA-HAL/KAL: + 2 grados
PEAD-RP-JA(L)
Funcin
Seal de filtro
Pres. esttica externa
Pres. esttica externa
Ajuste temp. modo calef.
(+4 grados) +1
Veloc. vent. con
termo. calef. OFF
Veloc. vent. con
termo. refrig. OFF
Deteccin
anormalidad del conducto
Configuraciones
100h
2500h
Sin indicador de signo de filtro
35/50/70/100/150Pa
35/50/70/100/150Pa
Disponible
No disponible
Extra baja
Parada
Ajuste de velocidad del ventilador
Ajuste de velocidad del ventilador
Parada
Disponible
No disponible
Modo N
Conf. N
07
1
2
3
08
10
24
25
27
28
2
1
2
3
1
2
1
2
N Conf.
Presin estt.
Externa
Modo n 08
Modo n 10
35Pa
50Pa
70Pa
100Pa
150Pa
Conf. inicial
(conf. fbrica)
58
15/6/10 16:28:27
Gama Industrial
00
00
00 00
00 00
00 00
00 00
11) Pulse el botn G y seleccione con los botones F el nmero de configuracin deseado.
023
00 00
023
13) Cuando queden fijos pulsaremos A y B o B y J (depende del modo que estemos
modificando), se apagar el mando. No opere el mando hasta transcurridos 30 segundos.
59
15/6/10 16:28:28
Configuracin de funciones
CAMBIA
N UNIDAD
NO
TERMIN
NO
SI
NOTA: Cuando conmuta a modo seleccin de funcin en el rea de operacin del control
remoto iinlambrico, la unidad finaliza el modo de seleccin de funcin automticamente si no
se ingresa nada por 10 minutos o ms.
60
15/6/10 16:28:28
Gama Industrial
PROCEDIMIENTO
1) Presione el botn SET usando una punta fina, le aparecer parpadeando MODEL SELECT y abajo a la izquierda el N de modelo
actual.
2) Presione los botones temperatura
de modelo que desee.
N de
Modelo
Botn
de temperatura
IMPORTANTE
Compruebe el modelo de la unidad en placa de caracteristicas de la misma, si el modelo
de la unidad interior no corresponde con el modo configurado en el control remoto,
pueden no aparecer todas sus funciones.
Botn SET
TIPO
N DE MODELO
001
PLH-P.KAH / PLA-P.KA
PLH-P.AAH / PLA-P.KA
PCH-P.GAH / PCA-P.GA
PKH-P.GALH / PKA-P.FAL
PKH-P.FALH / PKA-P.FAL
BOMBA DE CALOR
003
SOLO FRO
PLA-P.KA
PLA-P.AA
PCA-P.GA
PKA-P.GAL
PKA-P.FAL
033
035
61
15/6/10 16:28:28
Configuracin de funciones
DIAGRAMA DE FLUJO DE CONFIGURACIN DE FUNCIONES
Display normal (Display cuando el acondicionado no est funcionando)
Item 2
Item 1
CHANGE
LANGUAGE
Cambiar
Idioma
LANGUAGE
ENGLISH (GB)
LANGUAGE
DEUTSCH (D)
LANGUAGE
SPANISH (ES)
LANGUAGE
RUSSIAN (RU)
LANGUAGE
ITALIAN (IT)
LANGUAGE
CHINESE (CH)
LANGUAGE
FRENCH (FR)
LANGUAGE
JAPANESE (JP)
Item 3
Seleccin
de funcin
FUNCTION
SELECTION
OFF
LOOKING
FUNCTION
On1
On2
G
SELECT
AUTO MODE
ON
OFF
OFF
LIMIT TEMP
FUNCTION
LIMIT TEMP
COOL MODE
LIMIT TEMP
HEAT MODE
LIMIT TEMP
AUTO MODE
Seleccin
de modo
MODE
SELECTION
CONTROLLER
MAIN
D
D
CLOCK
CONTROLLER
MAIN
D
CONTROLLER
SUB
ON
D
G
TIMER SET
: ENTER
OFF
WEEKLY TIMER
AUTO OFF
TIMER
D
SIMPLE TIMER
TIMER MODE
OFF
G
D
OFF
CALL
D
DISF MODE
SETTING
TEMP MODE
C / F
ON
D
Configuracin de
modo de display
ROOM TEMP
DISP SELECT
CALL
OFF
ON
D
OFF
AUTO MODE
DISP C / H
ON
D
OFF
62
15/6/10 16:28:29
Gama Industrial
DIAGRAMA DE FLUJO DE CONFIGURACIN DE FUNCIONES
B
G
D
C
63
15/6/10 16:28:29
Agenda 2010
julio
agosto
septiembre
octubre
noviembre
MI
diciembre
MI
10
11
10
12
10
10
11
13
11
11
12
10
14
12
12
13
11
15
13
13
10
14
12
16
14
MI
14
11
15
13
17
15
15
12
16
14
18
16
16
13
17
15
19
17
17
14
18
16
20
18
18
15
19
17
21
19
19
16
20
18
22
20
20
17
21
19
23
21
MI
21
18
22
20
24
22
22
19
23
21
25
23
23
20
24
22
26
24
24
21
25
23
27
25
25
22
26
24
28
26
26
23
27
25
29
27
27
24
28
26
30
28
MI
28
25
29
27
29
29
26
30
28
30
30
27
29
31
31
28
30
29
31
30
31
64
15/6/10 16:28:29
Agenda 2011
enero
febrero
marzo
mayo
abril
junio
L
M
MI
3
4
MI
10
10
11
11
10
12
12
11
13
13
10
12
10
14
14
11
13
11
15
15
12
10
14
MI
12
16
16
13
11
15
13
17
17
14
12
16
14
18
18
15
13
17
15
19
19
16
14
18
16
20
20
17
15
19
17
21
21
18
16
20
18
22
22
19
17
21
MI
19
23
23
20
18
22
20
24
24
21
19
23
21
25
25
22
20
24
22
26
26
23
21
25
23
27
27
24
22
26
24
28
28
25
23
27
25
29
26
24
28
MI
26
30
27
25
29
27
31
28
26
30
28
29
27
29
30
28
30
29
31
30
31
65
15/6/10 16:28:29
Calendarios
CALENDARIO 2009
Enero
5
12
19
26
6
13
20
27
7
14
21
28
Febrero
1
8
15
22
29
2
9
16
23
30
3
10
17
24
31
4
11
18
25
Julio
6
13
20
27
7
14
21
28
2
9
16
23
3
10
17
24
Marzo
1
5 6 7 8
12 13 14 15
19 20 21 22
26 27 28
4
11
18
25
Agosto
1
8
15
22
29
2
9
16
23
30
3
10
17
24
31
4
11
18
25
5
12
19
26
3
10
17
24
31
4
11
18
25
5
12
19
26
6
13
20
27
2
9
16
23
30
3
10
17
24
31
4
11
18
25
5
12
19
26
6
13
20
27
7
14
21
28
Septiembre
7
14
21
28
1
8
15
22
29
2
9
16
23
30
7
14
21
28
1
8
15
22
29
2
9
16
23
30
Mayo
Abril
1
8
15
22
29
3
10
17
24
4
11
18
25
5
12
19
26
6
13
20
27
7
14
21
28
1
8
15
22
29
2
9
16
23
30
3
10
17
24
4
11
18
25
5
12
19
26
Octubre
6
13
20
27
5
12
19
26
6
13
20
27
7
14
21
28
1
8
15
22
29
4
11
18
25
5
12
19
26
6
13
20
27
Junio
7
14
21
28
1
8
15
22
29
2
9
16
23
30
3
10
17
24
31
Noviembre
2
9
16
23
30
3
10
17
24
31
4
11
18
25
2
9
16
23
30
3
10
17
24
4
11
18
25
5
12
19
26
6
13
20
27
1
8
15
22
29
2
9
16
23
30
3
10
17
24
4
11
18
25
5
12
19
26
6
13
20
27
7
14
21
28
Diciembre
7
14
21
28
1
8
15
22
29
7
14
21
28
1
8
15
22
29
2
9
16
23
30
3
10
17
24
31
4
11
18
25
5
12
19
26
6
13
20
27
3
10
17
24
4
11
18
25
5
12
19
26
6
13
20
27
CALENDARIO 2010
Enero
4
11
18
25
5
12
19
26
6
13
20
27
Febrero
7
14
21
28
1
8
15
22
29
2
9
16
23
30
3
10
17
24
31
Julio
5
12
19
26
6
13
20
27
1
8
15
22
2
9
16
23
3
10
17
24
4
11
18
25
Marzo
5
12
19
26
6
13
20
27
7
14
21
28
1
8
15
22
29
2
9
16
23
30
3
10
17
24
31
4
11
18
25
2
9
16
23
30
3 4
10 11
17 18
24 25
31
5
12
19
26
2 3
9 10
16 17
23 24
30 31
4
11
18
25
5
12
19
26
6
13
20
27
7
14
21
28
Septiembre
Agosto
7
14
21
28
1
8
15
22
29
6
13
20
27
7
14
21
28
1
8
15
22
29
6
13
20
27
7
14
21
28
1
8
15
22
29
2
9
16
23
30
3
10
17
24
4
11
18
25
5
12
19
26
6
13
20
27
7
14
21
28
1
8
15
22
29
2
9
16
23
30
3
10
17
24
4
11
18
25
Octubre
5
12
19
26
4
11
18
25
5
12
19
26
6
13
20
27
Junio
Mayo
Abril
7
14
21
28
3
10
17
24
31
4
11
18
25
5
12
19
26
6
13
20
27
7
14
21
28
1
8
15
22
29
2
9
16
23
30
Noviembre
1
8
15
22
29
2
9
16
23
30
3
10
17
24
31
1
8
15
22
29
2
9
16
23
30
3
10
17
24
4
11
18
25
5
12
19
26
6
13
20
27
7
14
21
28
1
8
15
22
29
2
9
16
23
30
Diciembre
7
14
21
28
6
13
20
27
7
14
21
28
1
8
15
22
29
2
9
16
23
30
3
10
17
24
31
4
11
18
25
5
12
19
26
2
9
16
23
30
3
10
17
24
4
11
18
25
5
12
19
26
3
10
17
24
31
4
11
18
25
CALENDARIO 2011
Enero
3
10
17
24
31
4
11
18
25
5
12
19
26
Febrero
6
13
20
27
7
14
21
28
1
8
15
22
29
2
9
16
23
30
7
14
21
28
1
8
15
22
29
2
9
16
23
30
3
10
17
24
31
Julio
4
11
18
25
5
12
19
26
6
13
20
27
1
7 8
14 15
21 22
28
2
9
16
23
3
10
17
24
Marzo
4
11
18
25
5
12
19
26
6
13
20
27
5
12
19
26
6
13
20
27
7
14
21
28
Agosto
1
8
15
22
29
2
9
16
23
30
3
10
17
24
31
4
11
18
25
7
14
21
28
1
8
15
22
29
2
9
16
23
30
3
10
17
24
31
4
11
18
25
5
12
19
26
6
13
20
27
Septiembre
5
12
19
26
6
13
20
27
7
14
21
28
Mayo
Abril
1
8
15
22
29
2
9
16
23
30
3
10
17
24
4
11
18
25
5
12
19
26
6
13
20
27
7
14
21
28
1
8
15
22
29
2 3
9 10
16 17
23 24
30
7
14
21
28
1
8
15
22
29
Octubre
4
11
18
25
3
10
17
24
31
4
11
18
25
5
12
19
26
6
13
20
27
2
9
16
23
30
3 4
10 11
17 18
24 25
31
Junio
5
12
19
26
6
13
20
27
7
14
21
28
1
8
15
22
29
5
12
19
26
6
13
20
27
Noviembre
2
9
16
23
30
7
14
21
28
1
8
15
22
29
2
9
16
23
30
3
10
17
24
4
11
18
25
6
13
20
27
7
14
21
28
1
8
15
22
29
Diciembre
5
12
19
26
6
13
20
27
7
14
21
28
1
8
15
22
29
2
9
16
23
30
66
15/6/10 16:28:30
Condiciones de Garanta
Mitsubishi Electric Europe B.V. Sucursal en Espaa (en adelante, Mitsubishi Electric) garantiza a sus clientes* los productos que Mitsubishi Electric comercializa en Espaa bajo la marca Mitsubishi Electric (u otras marcas de su titularidad) contra defectos de fabricacin
y/o funcionamiento en los trminos y plazos que se sealan a continuacin:
Gama Domstica y Comercial Mr. Slim:
2 AOS de garanta total
3 AOS para la sustitucin del compresor
Resto de Gamas:
6 MESES de garanta total
2 AOS para la sustitucin de componente averiado
3 AOS para la sustitucin del compresor
Estos plazos se computarn desde la fecha de primera adquisicin del producto, indicada en la factura de compra, no siendo acumulables.
Los equipos de segunda mano nicamente estarn cubiertos bajo la presente garanta cuando el plazo transcurrido desde la primera adquisicin sea inferior a los plazos indicados.
La garanta total comprende la reparacin del producto averiado o, caso de ser necesaria, su sustitucin, incluyendo no solo la pieza sino
tambin el transporte y la mano de obra. Fuera de los casos de garanta total, la sustitucin incluye nicamente el suministro, sin cargo, de
cualquier pieza defectuosa, quedando excluidos el desplazamiento y la mano de obra.
Las piezas sustituidas durante el periodo de garanta sern propiedad de Mitsubishi Electric.
Quedan en todo caso excluidas de la presente garanta las averas no imputables a los defectos de fabricacin y/o de los materiales, as
como las originadas por mala instalacin o manipulacin por personal no autorizado expresamente por Mitsubishi Electric, as como las
provocadas por tensiones de alimentacin indebidas o cualquier otra circunstancia ajena a Mitsubishi Electric. La presente garanta no
cubrir en ningn caso los desperfectos en partes cosmticas surgidos con posterioridad a la adquisicin del producto.
Bajo ninguna circunstancia, Mitsubishi Electric ser responsable de los daos que un equipo pueda causar a elementos externos.
Mitsubishi Electric o sus servicios tcnicos no realizarn reparaciones de ningn tipo en aquellos aparatos que estn instalados en lugares de difcil o imposible acceso, o en lugares que revistan peligrosidad para el operario que deba realizar la reparacin o cuando dichos
equipos hayan sido instalados incumpliendo la legislacin aplicable. En estos casos, si el equipo est cubierto por la garanta ser reparado
una vez dicho equipo haya sido previamente desinstalado por el cliente. Mitsubishi Electric no correr en ningn caso con los costes de
desinstalacin e instalacin del equipo. El equipo a reparar deber haber sido desinstalado por el cliente mientras el periodo de garanta est
en vigor.
*Esta garanta es otorgada por Mitsubishi Electric nicamente a sus clientes directos quienes, en caso de vender los equipos comprados a consumidores (por ser, a ttulo de
ejemplo, minoristas, instaladores, constructores, etc) debern ofrecer a stos, como mnimo, la garanta que legalmente se establezca en cada momento. No obstante, en caso
de que el cliente directo de Mitsubishi Electric tenga la condicin de consumidor, la presente garanta comercial se entiende sin perjuicio y adicionalmente a los derechos que el
consumidor pueda reclamar conforme a lo dispuesto en la legislacin aplicable.
67
15/6/10 16:28:30
Contacto
Recambios:
fax. 902.314.514
e-mail: recambios.aire@sp.mee.com
7213
GAMA DOMSTICA
Escriba dom seguido de un espacio e indique los parpadeos del piloto Operation Indicator.
MS INFORMACIN EN www.mitsubishielectric.es
Catlogos Comerciales
Manuales de usuario
Listado de servicios tcnicos (SAT)
...y mucha ms informacin.
68
15/6/10 16:28:30
15/6/10 16:28:30
UNE-EN-ISO 14001
En Mitsubishi Electric queremos colaborar con usted para preservar el medio ambiente.
Por eso, le recomendamos que cuando este folleto ya no le sea til, lo deposite en un contenedor de papel para reciclar.
Pape
r
Edicin 0410
ACMANTEC10
lly chlo
ri
-free
ne
a
tot
TCF
EMPRESA CERTIFICADA
15/6/10 16:28:30