Dual-Band Combiner

68 470 MHz

870 970 MHz

80 / 160 / 400 MHz

GSM 900

Port 1

Designed for inhouse multiband distribution


network
Enables feeder sharing

Port 2

DC by-pass between port 1 and port 3


Built-in DC stop between port 2 and port 3

12

15

32

18.7

Input
N coupler

4.3

Output
N coupler

40

105

111.6

Port 3

223

Input
N coupler

229.4

Typical Attenuation Curves

Port 3

Port 1
68 470 MHz

Port 2
870 970 MHz

Attenuation/dB

Diagram I
Port 1 Port 3

Port 2 Port 3

68 470

870 970

0
10
20
30
40

Technical Data
Type No.

50

728 954

60
70
80

68 470 MHz
870 970 MHz

90
100

< 0.5 dB (68 470 MHz)


< 0.5 dB (870 970 MHz)

100

200

300

400

500

600

700

800

900

1000

Frequency/MHz

> 45 dB
< 1.2
50
< 50 W
< 50 W
< 160 dBc (2 nd/3 rd order; with 2 x 20 W)
20 ... +70 C
N female
Indoor

Diagram II
Attenuation/dB

Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1
Band 2
Intermodulation products
Temperature range
Connectors
Application
DC transparency
Port 1 Port 3
Port 2 Port 3
Port 3 Port 2
Weight
Packing size
Dimensions (w x h x d)

Port 1 Port 3

Port 2 Port 3

68 470

870 970

0
0.1
0.2
0.3
0.4
0.5
0.6

By-pass (max. 2500mA)


short circuited
stop
0.8 kg
285 x 55 x 125 mm
229.4 x 32 x 111.6 mm
(without connectors)

0.7
0.8
0.9
1.0
0

100

200

300

400

500

600

700

800

900

1000

Frequency/MHz

231

Dual-Band Combiner
50 470 MHz

806 2500 MHz

PMR / TETRA / TETRAPOL

CDMA 800 / GSM 900 / GSM 1800 / UMTS / WLAN

Designed for co-siting purposes


Enables feeder sharing
Can be used as a combiner near the BTS or in a

reciprocal function near the antenna


Suitable for indoor or outdoor applications
Wall or mast mounting
External DC stop available as an accessory
Very low insertion loss
High input power

Port 3

Port 1

Port 2

782 10457

782 10458

782 10457

782 10458

782 10460

Technical Data
Type No.
Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1
Band 2
Intermodulation products
Temperature range
Connectors
Application
DC/AISG transparency
Port 1 Port 3
Port 2 Port 3
Mounting
Weight
Dimensions (w x h x d)

232

782 10460

87.5 470 MHz


806 2500 MHz

50 470 MHz
806 2500 MHz

< 0.15 dB (87.5 470 MHz)


< 0.15 dB (806 2500 MHz)

< 0.15 dB (50 470 MHz)


< 0.15 dB (806 2500 MHz)

> 50 dB (250 470 / 806 2500 MHz)


> 40 dB (87.5 250 MHz)
< 1.25 (87.5 470 / 806 960 / 1710 2500 MHz)
50

> 50 dB (50 470 / 806 2500 MHz)


< 1.25 (50 470 / 806 960 / 1710 2500 MHz)

< 500 W
< 500 W
< 160 dBc (3 rd order; with 2 x 20 W)
55 ... +60 C
7-16 female, long neck
Indoor or outdoor (IP 66)
By-pass (max. 2500 mA)
Stop
By-pass (max. 2500 mA)
By-pass (max. 2500 mA)
By-pass (max. 2500 mA)
Stop
Wall mounting: With 4 screws (max. 8 mm diameter)
Mast mounting: With additional clamp set
4 kg
122 x 52 x 284.7 mm (without connectors, without mounting brackets)

Dual-Band Combiner
50 470 MHz

806 2500 MHz

PMR / TETRA / TETRAPOL

CDMA 800 / GSM 900 / GSM 1800 / UMTS / WLAN

Typical Attenuation Curves


782 10457
Diagram I

Diagram II
Port 2 Port 3

0
10
20
806 2500

87.5 470
30

Port 1 Port 3

Attenuation/dB

Attenuation/dB

Port 1 Port 3

Port 2 Port 3

0
0.1
0.2
806 2500

87.5 470
0.3

40

0.4

50

0.5

60

0.6

70

0.7

80

0.8

90

0.9
1.0

100
0

250

500

750

1000 1250 1500 1750 2000 2250 2500

250

500

750

1000 1250 1500 1750 2000 2250 2500

Frequency/MHz

Frequency/MHz

782 10458
Diagram I

Diagram II
Port 2 Port 3

0
10
20
806 2500

87.5 470
30

Port 1 Port 3

Attenuation/dB

Attenuation/dB

Port 1 Port 3

0.1
0.2
806 2500

87.5 470
0.3

40

0.4

50

0.5

60

0.6

70

0.7

80

0.8

90

0.9

100

Port 2 Port 3

1.0
0

250

500

750

1000 1250 1500 1750 2000 2250 2500

250

500

750

Frequency/MHz

1000 1250 1500 1750 2000 2250 2500

Frequency/MHz

782 10460
Diagram I

Diagram II
Port 2 Port 3

0
10
20
806 2500

50 470
30

Port 1 Port 3

Attenuation/dB

Attenuation/dB

Port 1 Port 3

Port 2 Port 3

0
0.1
0.2
50 470

806 2500

0.3

40

0.4

50

0.5

60

0.6

70

0.7

80

0.8

90

0.9
1.0

100
0

250

500

750

1000 1250 1500 1750 2000 2250 2500

Frequency/MHz

250

500

750

1000 1250 1500 1750 2000 2250 2500

Frequency/MHz

233

Dual-Band Combiner
50 1000 MHz

1600 2000 MHz

80 / 160 / 400 / GSM 900

GSM 1800

Designed for inhouse multiband distribution network


Port 1

Enables feeder sharing


DC by-pass between port 1 and port 3
Built-in DC stop between port 2 and port 3

Port 2

Port 3

deep

Port 3

Port 1

Port 2

50 1000 MHz 1600 2000 MHz

Typical Attenuation Curves


Diagram I
Port 2 Port 3

Attenuation/dB

Port 1 Port 3
0
10
20

1600 2000

50 1000
30
40

Technical Data

Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR (all ports)
Impedance
Input power
Band 1
Band 2
Temperature range
Connectors
Application
DC transparency
Port 1 Port 3
Port 2 Port 3
Port 3 Port 2
Mounting
Weight
Packing size
Dimensions (w x h x d)

234

791 145

60
70

50 1000 MHz
1600 2000 MHz

80

< 0.3 dB (50 1000 MHz)


< 0.5 dB (1600 2000 MHz)

100

90

200

400

600

800

1000

1200

1400

1600

1800

2000

Frequency/MHz

> 40 dB (50 1000 / 1600 2000 MHz)


< 1.2 (50 1000 / 1600 2000 MHz)
50
< 100 W
< 50 W
30 +60 C
N female
Indoor
By-pass (max. 2500mA)
Short circuited
Stop
With 4 screws (max.4 mm diameter)
0.7 kg
220 x 40 x 140 mm
201 x 23 x 112 mm (incl. connectors)

Diagram II
Port 2 Port 3

Port 1 Port 3

Attenuation/dB

Type No.

50

0
0.1
0.2

1600 2000

50 1000

0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0

200

400

600

800

1000

1200

1400

1600

1800

Frequency/MHz

2000

Dual-Band Combiner
824 880 MHz

890 960 MHz

AMPS / CDMA 800

GSM 900

Designed for co-siting purposes


Enables feeder sharing
Suitable for indoor applications
Built-in DC stop between all ports

Port 1
Port 3
Port 2

Typical Attenuation Curves


Diagram I
Attenuation/dB

Port 1 Port 3

Port 2 Port 3

0
10
20
890 960

824 880
30
40
50
60
70

Technical Data

Pass band
Band 1 (AMPS / CDMA 800)
Band 2 (GSM 900)
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1
Band 2
Intermodulation products
Temperature range
Connectors
Application
Special features
Mounting
Weight
Dimensions (w x h x d)

782 10341

90
100
800

824 880 MHz


890 960 MHz

< 400 W (with max. 8 carriers)


< 400 W (with max. 8 carriers)
< 160 dBc (3 rd order; with 2 x 20 W)
20 ... +55 C
7-16 female
Indoor
Built-in DC stop between all ports
With 4 screws (max. 4 mm diameter)
3.2 kg
228 x 85 x 199.3 mm
(including connectors and mounting feet)

840

860

880

900

920

940

960

980

1000

Diagram II

< 0.6 dB (824 880 MHz)


< 0.6 dB (890 960 MHz)
> 55 dB (824 880 / 890 960 MHz)
< 1.2 (824 880 / 890 960 MHz)
50

820

Frequency/MHz

Port 1 Port 3

Attenuation/dB

Type No.

80

Port 2 Port 3

0
0.5
1.0
890 960

824 880
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
800

820

840

860

880

900

920

940

960

980

1000

Frequency/MHz

235

Dual-Band Combiner
790 862 MHz

880 960 MHz

DD (Digital Dividend) / CDMA 800

GSM 900

Designed for co-siting purposes


Enables feeder sharing
Can be used as a combiner near the BTS or
in a reciprocal function near the antenna
Suitable for indoor or outdoor applications
Wall or mast mounting
Available as a single unit, or for XPol antennas
as a double unit
Built-in lightning protection
External DC stop available as an accessory

790 862

Port 3

Port 1

Port 2

782 10970, 782 10972


Single Unit

880 960

782 10971, 782 10973


Double Unit

790 862

880 960

Technical Data
Type No.

Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1 / Band 2
Intermodulation products
Temperature range
Connectors
Application
DC/AISG transparency
Port 1 Port 3
Port 2 Port 3
Lightning protection
Mounting
Weight
Dimensions (w x h x d)

236

782 10970

782 10972

Single Unit

Single Unit

782 10971

782 10973

Double Unit

Double Unit
790 862 MHz
880 960 MHz

< 0.4 dB, typically 0.2 dB (790 862 MHz)


< 0.4 dB, typically 0.2 dB (880 960 MHz)
> 50 dB (790 862 MHz / 880 960 MHz)
< 1.2 (790 862 / 880 960 MHz)
50
< 200 W / < 200 W
< 160 dBc (3 rd order; with 2 x 20 W)
40 ... +60 C
7-16 female (long neck)
Indoor or outdoor (IP 66)
By-pass (max. 2500 mA)
By-pass (max. 2500 mA)

Stop
By-pass (max. 2500 mA)

3 kA, 10/350 s pulse


Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set
Single Unit: Approx. 3.2 kg / Double Unit: Approx. 6.1 kg
Single Unit: 175 x 51 x 207 mm / Double Unit: 175 x 106 x 207 mm
(without connectors, without mounting brackets)

Dual-Band Combiner
790 862 MHz

880 960 MHz

DD (Digital Dividend) / CDMA 800

GSM 900

Accessories (order separately)


Clamp set
suitable for mast
diameter of

Diagram I

Clamp Set
0

734 360

34 60 mm

734 361

60 80 mm

734 362

80 100 mm

734 363

100 120 mm

734 364

120 140 mm

50

734 365

45 125 mm

60

Type No.

Description

793 301

DC stop

DC stop

10
20
880 960

790 862
30
40

70

50- load

80
90

50- load
1.5 W / indoor or outdoor

100
780

800

820

840

860

880

900

920

940

960

980

Frequency/MHz

Diagram II
Port 2 Port 3

Port 1 Port 3

Attenuation/dB

784 10367

Port 2 Port 3

Port 1 Port 3

Attenuation/dB

Type No.

Calculated Attenuation Curves

Side view
Single Unit

0
0.5
1.0
880 960

790 862
1.5
2.0
2.5
3.0
3.5
4.0

Side view
Double Unit

4.5
5.0
780

800

820

840

860

880

900

920

940

960

980

Frequency/MHz

Top view
Single Unit,
Double Unit

Please note:

3
Bottom view
Single Unit,
Double Unit

The mounting plates can be removed by loosening the


screws 1 to 4 (M5 x 12) and replaced with other
means of mounting, always provided that the max.
drilled depth of 7.5 mm is respected with the choice of
replacement screws.

237

Dual-Band Combiner
806 960 MHz

1710 2170 MHz

CDMA 800 / GSM 900

GSM 1800 / UMTS

Designed for co-siting purposes


Enables feeder sharing
Can be used as a combiner near the BTS or
in a reciprocal function near the antenna
Suitable for indoor or outdoor applications
Wall or mast mounting
Available as a single unit, or for XPol antennas as a double unit
DC by-pass between all ports
DC stop available as an accessory

Port 3
Port 1

793 532
Single Unit

Port 2

793 533
Double Unit

Typical Attenuation Curves


Diagram I

Single Unit 793 532


Double Unit 793 533
(only 1 unit shown)

Attenuation/dB

Port 1 Port 3

Port 2 Port 3

0
10
2000 2170
20
806 960

1710 2000

30
40

Technical Data
Type No.

50

793 532
Single Unit

60

793 533

70

Double Unit

80

Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1
Band 2
Intermodulation products
Temperature range
Connectors
Application
Special features
Mounting
Weight
Packing size
Dimensions (w x h x d)

238

806 960 MHz


1710 2170 MHz

90
100
500

700

900

1100 1300 1500

Typically 0.15 dB (806 960 MHz)


Typically 0.25 dB (1710 2000 MHz)
Typically 0.35 dB (2000 2170 MHz)

1700 1900 2100 2300 2500

Frequency/MHz

Diagram II
> 45 dB (806 824 MHz)
> 50 dB (824 960 MHz)
> 50 dB (1710 2170 MHz)
< 1.2 (806 960 / 1710 2170 MHz)
50
< 250 W
< 200 W
< 160 dBc (2 nd/ 3 rd order; with 2 x 20 W)
55 ... +60 C
7-16 female
Indoor or outdoor (IP 66)
DC by-pass between all ports (max. 2500 mA)
Wall mounting: With 4 screws (max. 8 mm diameter)
Mast mounting: With additional clamp set
1.6 kg
3.0 kg
350 x 165 x 138 mm
350 x 165 x 190 mm
125 x 197.7 x 41.4 mm 125 x 197.7 x 91.8 mm
(without connectors, without mounting brackets)

Port 1 Port 3

Attenuation/dB

Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3

Port 2 Port 3

0
0.1
0.2
0.3
0.4
0.5
0.6
2000 2170
0.7
806 960

1710 2000

0.8
0.9
1.0
500

700

900

1100 1300 1500 1700 1900 2100 2300 2500

Frequency/MHz

Dual-Band Combiner
806 960 MHz

1710 2170 MHz

CDMA 800 / GSM 900

GSM 1800 / UMTS

Accessories (order separately)


Type No.

Clamp set
suitable for mast
diameter of

734 360

34 60 mm

734 361

60 80 mm

734 362

80 100 mm

734 363

100 120 mm

734 364

120 140 mm

734 365

45 125 mm

DC stop

50- load

M6

31.5

234
61.2*
40.5*

50- load 1.5 W


indoor or outdoor

281.8

coupler 7-16 (3x)


Side view
793 532
Single Unit

coupler 7-16 (6x)

784 10367

Description

793 301

DC stop

Type No.

Clamp Set

Side view
793 533
Double Unit
* Valid if labelled Dual-Band Combiner
labelled Dual-Band Combiner

V1 (not valid for previous version

Top view
793 532
Single Unit,
793 533
Double Unit

Bottom view
793 532
Single Unit,
4 screws M5 x 10
4 spring washers
5.5 DIN 6095

793 533
Double Unit

239

Dual-Band Combiner
470 960 MHz

1710 2170 MHz

DVB-H / CDMA 800 / GSM 900

GSM 1800 / UMTS

Designed for co-siting purposes


Enables feeder sharing
Can be used as a combiner near the BTS
or in a reciprocal function near the antenna
Suitable for indoor or outdoor applications
Wall or mast mounting
Available as a single unit, or for XPol antennas as a double unit
Built-in lightning protection
External DC stop available as an accessory
Very low insertion loss
High input power

Port 3
Port 1

Port 2

782 10248, 782 10250


Single Unit

782 10249, 782 10251


Double Unit

Technical Data
Type No.

Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1 / Band 2
Intermodulation products
Temperature range
Connectors
Application
DC/AISG transparency
Port 1 Port 3
Port 2 Port 3
Lightning protection
Mounting
Weight
Packing size
Dimensions (w x h x d)

240

782 10248

782 10250

Single Unit

Single Unit

782 10249

782 10251

Double Unit

Double Unit
470 960 MHz
1710 2170 MHz

< 0.1 dB (470 960 MHz), typically 0.05 dB (470 960 MHz)
< 0.1 dB (1710 2170 MHz), typically 0.05 dB (1710 2170 MHz)
> 45 dB (470 550 MHz) / > 55 dB (550 960 MHz) / > 65 dB (1710 2170 MHz)
< 1.2 (470 960 / 1710 2170 MHz)
50
< 700 W / < 650 W
< 160 dBc (2 nd/3 rd order; with 2 x 20 W)
55 ... +60 C
7-16 female (long neck)
Indoor or outdoor (IP 66)
By-pass (max. 2500 mA)
By-pass (max. 2500 mA)

Stop
By-pass (max. 2500 mA)

3 kA, 10/350 s pulse


Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set
Single Unit: 2.9 kg / Double Unit: 5.7 kg
Single Unit: 365 x 207 x 150 mm / Double Unit: 365 x 207 x 214 mm
Single Unit: 125 x 194.5 x 50 mm / Double Unit: 125 x 194.5 x 105.4 mm
(without connectors, without mounting brackets)

Dual-Band Combiner
470 960 MHz

1710 2170 MHz

DVB-H / CDMA 800 / GSM 900

GSM 1800 / UMTS

Accessories (order separately)


Clamp set
suitable for mast
diameter of

734 360

34 60 mm

734 361

60 80 mm

734 362

80 100 mm

734 363

100 120 mm

734 364

120 140 mm

734 365

45 125 mm

Type No.

Description

784 10367

Clamp Set
Typical Attenuation Curves
Diagram I
Port 1 Port 3
Attenuation/dB

Type No.

50- load

10
20
470 960

1710 2170

30
40
50

DC stop

60

50- load
1.5 W / indoor or outdoor

793 301

Port 2 Port 3

70
80

DC stop

90
100
400

600

800

1000 1200 1400 1600 1800 2000 2200 2400

Frequency/MHz

Diagram II
Attenuation/dB

Port 1 Port 3

Port 2 Port 3

0
0.1
0.2
470 960

1710 2170

0.3
0.4
0.5

64

Side view
Single Unit

0.6
0.7
0.8
0.9
1.0
400

600

800

1000 1200 1400 1600 1800 2000 2200 2400

Frequency/MHz

Side view
Double Unit

Port 3
470 - 960 MHz
1710 - 2170 MHz

Port 2
1710 - 2170 MHz

102

Port 1
470 - 960 MHz
470 - 960 MHz / 1710 - 2170 MHz

Top view
Single Unit,
Double Unit

3
Bottom view
Single Unit,
Double Unit

Please note:
The mounting plates can be removed by loosening the screws
1 to 4 (M5 x 10) and replaced with other means of mounting, always provided that the max. drilled depth of 8.5 mm is
respected with the choice of replacement screws.

4 screws M5 x 10
4 spring washers
5.5 DIN 6095

241

Dual-Band Combiner
470 960 MHz

1710 2700 MHz

DVB-H / CDMA 800 / GSM 900

GSM 1800 / UMTS / WiMAX / LTE 2600

Designed for co-siting purposes


Enables feeder sharing
Can be used as a combiner near the BTS or
in a reciprocal function near the antenna
Suitable for indoor or outdoor applications
Wall or mast mounting
Available as a single unit, or for XPol antennas as a double unit
Built-in lightning protection
External DC stop available as an accessory
Extremely small dimensions and low
weight
Very low insertion loss

Port 3

Port 1

Port 2

782 10660, 782 10662


Single Unit

782 10661, 782 10663


Double Unit

High input power

470 - 960

470 - 960

1710 - 2700

1710 - 2700

Technical Data
Type No.

Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1 / Band 2
Intermodulation products
Temperature range
Connectors
Application
DC/AISG transparency
Port 1 Port 3
Port 2 Port 3
Lightning protection
Mounting
Weight
Dimensions (w x h x d)

242

782 10660

782 10662

Single Unit

Single Unit

782 10661

782 10663

Double Unit

Double Unit
470 960 MHz
1710 2700 MHz

< 0.15 dB (470 960 MHz), typically 0.1 dB (470 960 MHz)
< 0.2 dB (1710 2700 MHz), typically 0.1 dB (1710 2700 MHz)
> 55 dB (470 960 MHz) / > 65 dB (1710 2700 MHz)
< 1.2 (470 960 / 1710 2700 MHz)
50
< 650 W / < 350 W
< 160 dBc (3 rd order with 2 x 20 W)
55 ... +60 C
7-16 female (long neck)
Indoor or outdoor (IP 66)
By-pass (max. 2500 mA)
By-pass (max. 2500 mA)

Stop
By-pass (max. 2500 mA)

3 kA, 10/350 s pulse


Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set
Single Unit: Approx. 1.0 kg / Double Unit: Approx. 1.9 kg
Single Unit: 126 x 145 x 38 mm / Double Unit: 126 x 145 x 93 mm
(without connectors, without mounting brackets)

Dual-Band Combiner
470 960 MHz

1710 2700 MHz

DVB-H / CDMA 800 / GSM 900

GSM 1800 / UMTS / WiMAX / LTE 2600

Accessories (order separately)


Type No.

Clamp set
suitable for mast
diameter of

734 360

34 60 mm

734 361

60 80 mm

734 362

80 100 mm

734 363

100 120 mm

734 364

120 140 mm

734 365

45 125 mm

Type No.

Description

784 10367
793 301

Clamp Set

50- load

DC stop

50- load
1.5 W / indoor or outdoor
DC stop

Side view
Single Unit

Side view
Double Unit

Top view
Single Unit,
Double Unit

243

Dual-Band Combiner
380 960 MHz

1710 2700 MHz

TETRA / DVB-H / CDMA 800 / GSM 900

GSM 1800 / UMTS / WiMAX / LTE 2600

Designed for co-siting purposes


Enables feeder sharing
Can be used as a combiner near the BTS or
in a reciprocal function near the antenna
Suitable for indoor or outdoor applications
Wall or mast mounting
Available as a single unit, or for XPol antennas
as a double unit
Built-in lightning protection
External DC stop available as an accessory
Extremely low insertion loss
High input power

380 960

Port 1

Port 3

Port 2

782 10681, 782 10683


Double Unit

782 10680, 782 10682


Single Unit

380 960

1710 2700

1710 2700

Technical Data
Type No.

Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1 / Band 2
Intermodulation products
Temperature range
Connectors
Application
DC/AISG transparency
Port 1 Port 3
Port 2 Port 3
Lightning protection
Mounting
Weight
Packing size
Dimensions (w x h x d)

244

782 10680

782 10682

Single Unit

Single Unit

782 10681

782 10683

Double Unit

Double Unit
380 960 MHz
1710 2700 MHz

< 0.1 dB (380 960 MHz), typically 0.05 dB (380 960 MHz)
< 0.1 dB (1710 2700 MHz), typically 0.05 dB (1710 2700 MHz)
> 55 dB (380 550 MHz) / > 65 dB (550 960 MHz) / > 65 dB (1710 2700 MHz)
< 1.2 (380 960 / 1710 2700 MHz)
50
< 700 W / < 650 W
< 160 dBc (3 rd order; with 2 x 20 W)
55 ... +60 C
7-16 female (long neck)
Indoor or outdoor (IP 66)
By-pass (max. 2500 mA)
By-pass (max. 2500 mA)

Stop
By-pass (max. 2500 mA)

3 kA, 10/350 s pulse


Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set
Single Unit: 2.2 kg / Double Unit: 4.3 kg
Single Unit: 365 x 207 x 150 mm / Double Unit: 365 x 207 x 214 mm
Single Unit: 117 x 210 x 50 mm / Double Unit: 117 x 210 x 102 mm
(without connectors, without mounting brackets)

Dual-Band Combiner
380 960 MHz

1710 2700 MHz

TETRA / DVB-H / CDMA 800 / GSM 900

GSM 1800 / UMTS / WiMAX / LTE 2600

Typical Attenuation Curves

Accessories (order separately)


Clamp Set

Diagram I
Port 1 Port 3

Attenuation/dB

Clamp set
suitable for mast
diameter of

Type No.
734 360

34 60 mm

734 361

60 80 mm

734 362

80 100 mm

734 363

100 120 mm

734 364

120 140 mm

50

734 365

45 125 mm

60

Type No.

Description

50- load

Port 2 Port 3

0
10
20
380 960

1710 2700

30
40

70

784 10367

DC stop

80

50- load
1.5 W / indoor or outdoor

793 301

90
100

DC stop

300

600

900

1200 1500 1800

2100 2400 2700 3000

Frequency/MHz

Diagram II
Attenuation/dB

Port 1 Port 3

Port 2 Port 3

0
0.1
0.2
380 960

1710 2700

0.3
0.4
0.5
0.6

Side view
Single Unit

0.7
0.8
0.9
1.0
0

300

600

900

1200 1500 1800

2100 2400 2700 3000

Frequency/MHz
Side view
Double Unit

Top view
Single Unit,
Double Unit

3
Bottom view
Single Unit,
Double Unit

Please note:
The mounting plates can be removed by loosening
the screws 1 to 4 (M5 x 12) and replaced with
other means of mounting, always provided that the
max. drilled depth of 7.5 mm is respected with the
choice of replacement screws.

4 screws M5 x 12

245

Dual-Band Combiner
806 1880 MHz

1920 2170 MHz

CDMA 800 / GSM 900 / GSM 1800

UMTS

Designed for co-siting purposes


Enables feeder sharing
Can be used as a combiner near the BTS Port 1
or in a reciprocal function near the antenna
Suitable for indoor or outdoor applications
Port 2
Wall or mast mounting
Available as a single unit, or for XPol antennas as a double unit
Built-in lightning protection
External DC Stop available as an accessory

Port 3

782 10278, 782 10305


Single Unit

782 10279, 782 10306


Double Unit

Port 3

Port 1
806 1880

Port 3

Port 2
1920 2170

Port 1
806 1880

Port 2
1920 2170

Single Unit 782 10305


Double Unit 782 10306
(only 1 unit shown)

Single Unit 782 10278


Double Unit 782 10279
(only 1 unit shown)

Technical Data
Type No.
Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2

782 10278

782 10279

782 10305

782 10306

Single Unit

Double Unit

Single Unit

Double Unit

806 1880 MHz


1920 2170 MHz
< 0.1 dB, typically 0.05 dB (806 960 MHz) / < 0.4 dB, typically 0.2 dB (1710 1880 MHz)
< 0.4 dB typically 0.2 dB (1920 2170 MHz)
> 55 dB (806 960 MHz) / > 50 dB (1710 1880 MHz)
> 50 dB (1920 1980 MHz) / > 50 dB (2110 2170 MHz)
< 1.2 (806 960 MHz) / < 1.25 (1710 1880 MHz)
< 1.2 (1920 2170 MHz)
50

VSWR
Impedance
Input power
Band 1 / Band 2
Intermodulation products
Temperature range
Connectors
Application
DC/AISG transparency
Port 1 Port 3
Port 2 Port 3
Lightning protection
Mounting
Weight
Packing size
Dimensions (w x h x d)

246

< 500 W / < 500 W


< 160 dBc (2 nd/ 3 rd order; with 2 x 20 W)
55 ... +60 C
7-16 female (long neck)
Indoor or outdoor (IP 66)
By-pass (max. 2500 mA)
By-pass (max. 2500 mA)

3.4 kg
430 x 210 x 150 mm
130 x 269.6 x 43 mm

Stop
By-pass (max. 2500 mA)

3 kA, 10/350 s pulse


Wall mounting: With 4 screws (max. 8 mm diameter)
Mast mounting: With additional clamp set
6.6 kg
3.4 kg
6.6 kg
430 x 210 x 220 mm
430 x 210 x 150 mm
430 x 210 x 220 mm
130 x 269.6 x 98.5 mm
130 x 269.6 x 43 mm
130 x 269.6 x 98.5 mm
(without connectors, without mounting brackets)

Dual-Band Combiner
806 1880 MHz

1920 2170 MHz

CDMA 800 / GSM 900 / GSM 1800

UMTS

Accessories (order separately)


Type No.

Clamp set
suitable for mast
diameter of

734 360

34 60 mm

80 100 mm

734 363

100 120 mm

734 364

120 140 mm

734 365

45 125 mm

Type No.

Description

784 10367

Diagram I
Port 2 Port 3

Port 1 Port 3

60 80 mm

734 362

793 301

Typical Attenuation Curves

Attenuation/dB

734 361

Clamp Set

DC stop

10
20

1920 2170

806 1880

30
40

50- load

50

DC stop

60

50- load 1.5 W


indoor or outdoor

70
80
90
100
500

700

900

1100

1300

1500

1700

1900

2100

2300

2500

Frequency/MHz

Diagram II
Port 2 Port 3

Attenuation/dB

Port 1 Port 3

Side view, 782 10278, 782 10305 Single Unit

0
0.1
0.2
806 1880

1920 2170

0.3
0.4
0.5
0.6
0.7
0.8
0.9

Side view, 782 10279, 782 10306 Double Unit


1.0
500

700

900

1100

1300

1500

1700

1900

2100

2300 2500

Frequency/MHz

Port 1

Port 3

Port 2

Top view, 782 10278, 782 10305 Single Unit,


782 10279, 782 10306 Double Unit

Please note:
The mounting plates can be removed by loosening the screws
1 to 4 (M5 x 10) and replaced with other means of mounting,
always provided that the max. drilled depth of 8.5 mm is
respected with the choice of replacement screws.

4 screws M5 x 10
4 spring washers
5.5 DIN 6095

Bottom view, 782 10278, 782 10305 Single Unit,


782 10279, 782 10306 Double Unit
247

Dual-Band Combiner
1710 1880 MHz

1920 2170 MHz

GSM 1800

UMTS

Designed for co-siting purposes


Enables feeder sharing
Can be used as a combiner near the BTS

Port 3
Port 1

or in a reciprocal function near the antenna

Suitable for indoor or outdoor applications


Wall or mast mounting
Available as a single unit, or for XPol antennas as a double unit

Port 2

782 10620, 782 10622, 782 10624


Single Unit

782 10621, 782 10623, 782 10625


Double Unit

Built-in lightning protection


External DC Stop available as an accessory

Technical Data
Type No.

Pass band
Band 1 (GSM 1800)
Band 2 (UMTS)
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1 / Band 2
Intermodulation products
Temperature range
Connectors
Application
DC/AISG transparency
Port 1 Port 3
Port 2 Port 3
Lightning protection
Mounting
Weight
Packing size
Dimensions (w x h x d)

248

782 10620

782 10622

782 10624

Single Unit

Single Unit

Single Unit

782 10621

782 10623

782 10625

Double Unit

Double Unit

Double Unit

1710 1880 MHz


1920 2170 MHz
< 0.3 dB (1710 1880 MHz)
< 0.3 dB (1920 2170 MHz)
> 50 dB (1710 1880 / 1920 2170 MHz)
< 1.25 (1710 1880 / 1920 2170 MHz)
50
< 300 W / < 300 W
< 160 dBc (3 rd order; with 2 x 20 W)
40 ... +60 C
7-16 female (long neck)
Indoor or outdoor (IP 66)
By-pass (max. 2500 mA)
By-pass (max. 2500 mA)

Stop
By-pass (max. 2500 mA)

By-pass (max. 2500 mA)


Stop

3 kA, 10/350 s pulse


Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set
Single Unit: 2.9 kg / Double Unit: 5.7 kg
Single Unit: 392 x 272 x 139 mm / Double Unit: 392 x 272 x 189 mm
Single Unit: 199 x 199 x 48 mm / Double Unit: 199 x 199 x 100 mm
(without connectors, without mounting brackets)

Dual-Band Combiner
1710 1880 MHz

1920 2170 MHz

GSM 1800

UMTS

Typical Attenuation Curves

Accessories (order separately)


Clamp Set

Clamp set
suitable for mast
diameter of

734 360

34 60 mm

734 361

60 80 mm

734 362

80 100 mm

734 363

100 120 mm

734 364

120 140 mm

-50

734 365

45 125 mm

-60

Type No.

Description

784 10367

DC stop

-10
-20
1710 1880

1920 2170

-30
-40

-70

50- load

-80

DC stop

-90

50- load 1.5 W


indoor or outdoor

-100
1400

1500

1600

1700

1800

1900

2000

2100

2200

2300 2400

Frequency/MHz

Diagram II
Port 1 Port 3

Side view
Single Unit

Attenuation/dB

793 301

Port 2 Port 3

Port 1 Port 3

Attenuation/dB

Type No.

Diagram I

Port 2 Port 3

0
-0.1
-0.2
1710 1880

1920 2170

-0.3
-0.4

Side view
Double Unit

-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
1400

1500

1600

1700

1800

1900

2000

2100

2200

2300 2400

Frequency/MHz
Top view
Single Unit,
Double Unit

Bottom view
Single Unit,
Double Unit

Please note:
The mounting plates can be removed by loosening the
screws 1 to 4 (M5 x 12) and replaced with other
means of mounting, always provided that the max.
drilled depth of 7.5 mm is respected with the choice of
replacement screws.

249

Dual-Band Combiner
1850 1910 / 1930 1990 MHz

1710 1755 / 2110 2155 MHz

PCS

AWS

Designed for co-siting purposes


Enables feeder sharing
Suitable for indoor or outdoor applications
With fault detection and integrated switch
for multiple DC power supply

COM ANT

AWS

PCS

782 10469

Typical Attenuation Curves


Diagram I

Technical Data

Pass band
Band 1 (PCS)
Band 2 (AWS)
Insertion loss
Port PCS Port ANT
Port AWS Port ANT
Isolation
Port PCS Port AWS
VSWR
Impedance
Input power
Port PCS
Port AWS
Intermodulation products
Power supply voltage
operational
survival
Polarity protection
Max. Current
Power supply current at PCS port
operating with dummy load
Lightning protection
Temperature range
Connectors
Application
Weight
Dimensions (w x h x d)

250

782 10469

782 10808

Single unit

Double unit

Port
Port
PCS ANT

Port
Port
AWS ANT

0
-10
1850 1910
-20
-30

1710 1755

1930 1990

2110 2155

-40
-50

1850 1910 (Rx) / 1930 1990 (Tx) MHz


1710 1755 (Rx) / 2110 2155 (Tx) MHz

-60
-70

< 0.3 dB (1850 1910 / 1930 1990 MHz)


< 0.2 dB (1710 1755 / 2110 2155 MHz)

-80
-90

> 50 dB (1850 1910 / 1930 1990 MHz)


> 50 dB (1710 1755 / 2110 2155 MHz)
< 1.25 (1850 1910 / 1930 1990 MHz)
< 1.25 (1710 1755 / 2110 2155 MHz)
50
< 250 W (1850 1910 / 1930 1990 MHz)
< 250 W (1710 1755 / 2110 2155 MHz)
< 160 dBc (3 rd order; with 2 x 20 W)
+10 +15 V DC (Port PCS)
+10 +30 V DC (Port AWS)
+10 +35 V DC
48 V DC (Port PCS, Port AWS)
1.5 A (Port ANT)

-100
1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200

Frequency/MHz

Diagram II
Port
Port
AWS ANT

Attenuation/dB

Type No.

Attenuation/dB

Port
Port
AWS ANT

Port
Port
PCS ANT

Port
Port
AWS ANT

0
-0.1
-0.2
2110 2155

1710 1755
-0.3
1850 1910
-0.4
1930 1990
-0.5

100 mA 20 mA (+10 ... +15 V DC)


8/20 s, 20 kA; 10/350 s, 3 kA (Port ANT)
40 ... +65 C
7-16 female (long neck)
Indoor or outdoor (IP 66)
2.5 kg
5 kg
122 x 216.3 x 47 mm 122 x 216.3 x 102.6 mm
(without connectors, without mounting brackets)

-0.6
-0.7
-0.8
-0.9
-1.0
1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200

Frequency/MHz

Dual-Band Combiner
1850 1910 / 1930 1990 MHz

1710 1755 / 2110 2155 MHz

PCS

AWS

Designed for co-siting purposes


Enables feeder sharing
Suitable for indoor or outdoor applications

COM ANT

DC by-pass between all ports


External DC stop available as an accessory

AWS

PCS

782 10809

Typical Attenuation Curves


Diagram I
Attenuation/dB

Port
Port
AWS ANT

Port
Port
PCS ANT

Port
Port
AWS ANT

0
-10
1850 1910
-20
-30

1710 1755

1930 1990

2110 2155

-40
-50
-60

Technical Data

Pass band
Band 1 (PCS)
Band 2 (AWS)
Insertion loss
Port PCS Port ANT
Port AWS Port ANT
Isolation
Port PCS Port AWS
VSWR
Impedance
Input power
Port PCS
Port AWS
Intermodulation products
Lightning protection
Temperature range
Connectors
Application
DC/AISG transparency
Weight
Dimensions (w x h x d)

782 10809

782 10810

Single unit

Double unit

-80
-90
-100
1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200

1850 1910 (Rx) / 1930 1990 (Tx) MHz


1710 1755 (Rx) / 2110 2155 (Tx) MHz

Frequency/MHz

< 0.3 dB (1850 1910 / 1930 1990 MHz)


< 0.2 dB (1710 1755 / 2110 2155 MHz)
> 50 dB (1850 1910 / 1930 1990 MHz)
> 50 dB (1710 1755 / 2110 2155 MHz)
< 1.25 (1850 1910 / 1930 1990 MHz)
< 1.25 (1710 1755 / 2110 2155 MHz)
50
< 250 W (1850 1910 / 1930 1990 MHz)
< 250 W (1710 1755 / 2110 2155 MHz)
< 160 dBc (3 rd order; with 2 x 20 W)
3 kA, 10/350 s pulse
40 ... +65 C
7-16 female (long neck)
Indoor or outdoor (IP 66)
By-pass between all ports (max. 2500 mA)
2.5 kg
5 kg
122 x 216.3 x 47 mm 122 x 216.3 x 102.6 mm
(without connectors, without mounting brackets)

Diagram II
Port
Port
AWS ANT

Attenuation/dB

Type No.

-70

Port
Port
PCS ANT

Port
Port
AWS ANT

0
-0.1
-0.2
2110 2155

1710 1755
-0.3
1850 1910
-0.4
1930 1990
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0

1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200

Frequency/MHz

251

Dual-Band Combiner
1710 2180 MHz

2400 2700 MHz

GSM 1800 / PCS 1900 / AWS / UMTS

WLAN / WiMAX 2.6 / UMTS 2.6 / BRS / LTE

Designed for co-siting purposes


Enables feeder sharing
Can be used as a combiner near the BTS or
in a reciprocal function near the antenna
Suitable for indoor or outdoor applications
Wall or mast mounting
Built-in lightning protection
External DC stop available as an accessory

Port 3
Port 1

Port 2

Port 3

Port 1
1710 2180

Port 2
2400 2700

Typical Attenuation Curves


Diagram I

Top view

Side view

Attenuation/dB

Port 1 Port 3

Port 2 Port 3

0
10
20
1710 2180

2400 2700

30
40

Technical Data

50

Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1 / Band 2
Intermodulation products
Temperature range
Connectors
Application
DC/AISG transparency
Port 1 Port 3
Port 2 Port 3
Lightning protection
Mounting
Weight
Dimensions (w x h x d)

252

782 10800

60
70

1710 2180 MHz


2400 2700 MHz

80
90

< 0.15 dB
< 0.15 dB

100
1500 1650 1800 1950 2100

< 275 W / < 150 W


< 160 dBc (3 rd order; with 2 x 20 W)
40 ... +60 C
7-16 female, long neck
Indoor or outdoor (IP 66)

2250 2400 2550 2700 2850 3000

Frequency/MHz

> 50 dB
< 1.25 (1710 2180 / 2400 2700 MHz)
50

Diagram II
Port 1 Port 3

Attenuation/dB

Type No.

Port 2 Port 3

0
0.1
0.2
1710 2180

2400 2700

0.3
0.4
0.5

By-pass (max. 2500 mA)


By-pass (max. 2500 mA)
3 kA, 10/350 s pulse
Wall mounting: With 4 screws (max. 8 mm diameter)
Mast mounting: With additional clamp set
2.9 kg
199 x 199 x 49 mm
(without connectors, without mounting brackets)

0.6
0.7
0.8
0.9
1.0
1500 1650 1800 1950 2100

2250 2400 2550 2700 2850 3000

Frequency/MHz

Dual-Band Combiner
50 2200 MHz

2400 2500 MHz

80 / 160 / 400 / 900 / 1800 / UMTS

WLAN

Designed for inhouse multiband distribution networks


Enables feeder sharing
DC by-pass between ports 1 and 3
Built-in DC stop between ports 2 and 3

Port 3

Port 1

Port 2

Typical Attenuation Curves


Diagram I
Port 2 Port 3

Attenuation/dB

Port 1 Port 3
0
10

2400 2500
20
50 2200
30
40

Technical Data

50

Pass band
Band 1
Band 2
Insertion loss
Port 1 Port 3
Port 2 Port 3
Isolation
Port 1 Port 2
VSWR
Impedance
Input power
Band 1
Band 2
Intermodulation products
Temperature range
Connectors
Application
Special features
Mounting
Weight
Packing size
Dimensions (w x h x d)

782 10264

60
70

50 2200 MHz
2400 2500 MHz

80
90

< 0.1 dB (50 2200 MHz)


< 0.2 dB (2400 2500 MHz)
> 50 dB (50 2200 / 2400 2500 MHz)
< 1.25 (50 2200 / 2400 2500 MHz)
50
< 200 W
< 200 W
< 150 dBc (3 rd order; with 2 x 20 W)
20 ... +55 C
N female
Indoor
Built-in DC stop between ports 2 and 3
DC by-pass between ports 1 and 3 (max. 2500 mA)
With 4 screws (max. 4 mm diameter)
0.47 kg
225 x 140 x 75 mm
86 x 30.4 x 181.4 mm
(including connectors and mounting feet)

100
0

300

600

900

1200 1500

1800 2100 2400 2700 3000

Frequency/MHz

Diagram II
Port 1 Port 3

Attenuation/dB

Type No.

Port 2 Port 3

0
0.1
2400 2500

0.2
50 2200

0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0

300

600

900

1200 1500 1800 2100 2400 2700 3000

Frequency/MHz

253