Figure 1
Figure 2
Figure 3
DESCRIPTIONS
DAVIT ARM ONLY: See Figure 1.
8004030: Davit arm, 24 inch reach, 79 inch height. Standard Model
8002001: Davit Arm, 24 inch reach, 97 inch height (not shown).
8002002: Davit Arm, 48 inch reach, 79 inch height (not shown).
8002003: Davit Arm, 36 inch reach, 96 inch height (not shown).
8002004: Davit Arm, 21 inch reach, 66 inch height (not shown).
8002005: Davit Arm, 36 inch reach, 114.5 inch height (not shown).
8002006: Davit Arm, 24 inch reach, 71 inch height (not shown).
8002008: Davit Arm, 16 inch reach, 63 inch height (not shown).
8002009: Davit Arm, 20 inch reach, 59 inch height (not shown).
8002010: Davit Arm, 16 inch reach, 53 inch height (not shown).
1.0
APPLICATIONS
1.1
1.2
CAPACITY: The maximum working load for this product is 350 lbs.
B.
Model
Fall
Arrest
Work
Positioning
Personnel
Riding
Material
Handling
Rescue
8004030
8002001
8002002
8002003
8002004
8002005
8002006
8002008
8002009
8002010
C.
FREE FALL: Personal fall arrest systems must be rigged to limit the
free fall to six feet (according to ANSI Z359.1, or five feet according to
ANSI A10.14).
D.
1.3
E.
F.
2.0
SYSTEM REQUIREMENTS
2.1
2.2
2.3
Fall Arrest: The structure selected for personal fall arrest applications
must be capable of sustaining static loads applied in the directions
permitted by the personal fall arrest system of at least: 3,600 lbs. with
certification of a qualified person; or 5,000 lbs. without certification. See
ANSI Z359.1 for certification definition. When more than one personal
fall arrest system is attached to a structure, the strengths stated above
must be met at each location independently.
From OSHA 1926.500 and 1910.66: Anchorages used for attachment
of personal fall arrest systems shall be independent of any anchorage
being used to support or suspend platforms, and capable of supporting
at least 5,000 lbs. per user attached, or be designed, installed, and
used as part of a complete personal fall arrest system which maintains
a safety factor of at least two, and is under the supervision of a
qualified person.
B.
C.
D.
E.
WARNING: Davit arms and mounting bases that are installed for personnel
riding, material handling, or rescue applications only, must be labeled as such to
prevent the system from being used for fall arrest or work positioning
applications, which require greater structural strength.
3.0
3.2
PLAN your system before using this equipment. Consider all factors that
will affect your safety during use of this equipment. Consider the following
points when planning your system:
A.
WORK SITE GEOMETRY: The installation and use of the davit arm
and mounting base must be consistent with the geometric
requirements specified in sections 3.4 and 3.5. When suspending
working lines from the davit arm, check for obstructions or sharp edges
in the work path. Avoid working where the user may swing and hit an
object, or where lines may cross or tangle with that of another worker.
C.
BACK-UP FALL ARREST SYSTEM: When using the davit arm and
mounting base as a support for suspending a worker at a work level, or
for personnel riding applications, a back-up fall arrest system is
required. See OSHA 29 CFR 1910.28 and 1926.451. The davit arm has
an auxiliary connection point for a back-up personal fall arrest system.
D.
3.3
3.4
FIXED BASE: See Figure 4. The fixed base davit bases are for general
purpose use for most applications. The fixed base davit bases are
attached to concrete (8002040, 8004032) or other structural materials
(8002050, 8004031). A minimum of six equally spaced 1/2 inch
diameter fasteners are required to attach the davit base to the structure.
See Table 2 for fastener load requirements. DBI/SALA recommends
that all fixed base installations be done under the supervision of a
qualified person.
B.
WALL MOUNT: See Figure 5. The 8004273 and 8004274 davit bases
are used when bolting the davit arm to a wall or other vertical surface.
Use twelve 1/2 inch diameter fasteners to attach the davit base to the
structure. See Table 3 for fastener load requirements. The 8004230 and
8004235 davit bases are dimensionally the same, but are welded to
the structure. See below for information on welded installations.
C.
SHELF MOUNT: See Figure 6. The 8003773 davit base is used when a
shelf-type mounting on a wall or other vertical surface is required. Use
10
Figure 4
Arm
Reach
Fall arrest, no
cer tification,
work positioning
up to
24"
5,000
up to
24"
3,600
7,200
Personnel riding,
material handling,
rescue
up to
24"
2,500
5,000
Material handling,
rescue
Material handling,
rescue
up to
36"
up to
48"
3,300
2,500
10,000
10,000
10,000
4,775
2,625
12
2,800
1,550
3,425
1,900
12
2,025
1,150
2,400
1,325
12
1,400
775
4,775
2,625
12
2,800
1,550
4,775
2,650
12
2,800
1,550
the shelf mount with davit base models 8002050 or 8004031. Use six
1/2 inch diameter fasteners to attach the davit base to the structure.
See Table 4 for fastener load requirements.
11
Figure 5
Vertical
Load
(lbs.)
Moment
(ft-lbs.)
Torque
(ft-lbs.)
Fall arrest, no
cer tification,
work positioning
up to
24"
5,000
11,000
up to
24"
3,600
Personnel riding,
material handling,
rescue
up to
24"
Material handling,
rescue
Material handling,
rescue
Shear
10,000
2,300
1,980
7,900
7,200
1,650
1,425
2,500
5,500
5,000
1,150
990
up to
36"
3,300
11,000
10,000
2,300
1,300
up to
48"
2,500
11,000
10,000
2,300
990
D.
POST MOUNT: See Figure 7. The 8004392 davit base is used when a
single post can be inserted into a hole in the concrete or other
horizontal surface. A hole (3-1/16" in diameter) that is at least 6-1/4"
deep is required for the base to set into. A 1/2" bolt secures the post to
the horizontal surface. See Table 5 for fastener load requirements.
E.
12
Figure 6
Vertical
Load
(lbs.)
Moment
(ft-lbs.)
Torque
(ft-lbs.)
Fall arrest, no
cer tification,
work positioning
up to
24"
5,000
12,500
up to
24"
3,600
Personnel riding,
material handling,
rescue
up to
24"
Material handling,
rescue
Maerial handling,
rescue
Shear
10,000
5,000
4,850
9,000
7,200
3,600
3,500
2,500
6,250
5,000
2,500
2,425
up to
36"
3,300
12,500
10,000
5,000
3,200
up to
48"
2,500
12,500
10,000
5,000
4,850
F.
G.
H.
13
Figure 7
Arm
Reach
Moment
(ft-lbs.)
up to
24"
5,000
12,500
up to
24"
3,600
9,000
up to
24"
2,500
6,250
up to
36"
3,300
12,500
up to
48"
2,500
12,500
3.5
3.6
14
Figure 8
Do not position the davit arm where the worker will have to swing under
the davit arm to reach the work area. Avoid positioning the davit arm
where the working line may abrade against sharp edges when in use.
WARNING: Never allow the working line to extend outside the legs of the portable
base, tipping of the base could occur.
D.
Step 1.
Step 2.
Step 3.
15
Fall arrest, no
cer tification,
work positioning
Front 1,730
Front 1,245
Personnel riding,
material handling,
rescue
Rear
1,540
Rear
1,110
Front
865
Rear
770
Figure 9
Step 4.
Step 5.
Step 6.
CONNECTING EQUIPMENT TO
THE DAVIT ARM: The davit arm is
equipped with three system
connection points. Two connection
points are quick-mount brackets for
the Salalift winch or self retracting
lifeline. The third connection point is
an auxiliary connection for other
DBI/SALA systems.
Figure 10
16
Figure 11
4.0
4.1
TRAINING
It is the responsibility of the user and
purchaser of this equipment to be
17
trained in the correct care and use of this equipment. The user and
purchaser must be aware of the operating characteristics, application limits,
and consequences of improper use of this equipment.
5.0
5.1
INSPECTION
FREQUENCY:
Before Each Use: Inspect according to steps listed in section 5.2 and 5.3.
Monthly: A formal inspection of the davit arm and base should be done
by a competent person other than the user. See sections 5.2 and 5.3.
Record inspection results in the inspection and maintenance log in
section 9.0 of this manual.
After a Fall Arrest: Inspect entire davit arm and base according to
section 5.3.
WARNING: If the davit arm and mounting base have been subjected to fall arrest
forces, they must be immediately removed from service and inspected. If the davit
arm or mounting base fails inspection remove from service and destroy, or
contact DBI/SALA for repair or replacement.
IMPORTANT: Extreme working conditions (harsh environments, prolonged use)
may require increasing the frequency of inspections.
5.2
Inspect all bolts and nuts to ensure they are secure. Check for
missing, substituted, or altered parts.
Step 2.
Upper arm and lower leg on davit arm must be straight and free of
cracks, dents, distortion, or any other damage.
Step 3.
Locking lever on davit arm must work prevent arm from turning
when locked.
Step 4.
Upper arm on davit arm must collapse properly and can be locked
into place with detent pin.
Step 5.
Step 6.
Step 7.
18
Step 9.
All labels must be present and fully legible. See section 8.0.
Step 10. Record results of inspection in the inspection and maintenance log
in section 9.0 of this manual.
Step 11. Inspect each system component in accordance to manufacturers
instructions.
5.3
NOTE: Only DBI/SALA or parties authorized in writing may make repairs to this
equipment.
6.0
6.1
Periodically clean the exterior of the davit arm and base using water and
mild detergent. Clean labels as required.
6.2
6.3
6.4
Store this equipment in a clean and dry environment out of direct sunlight.
Avoid areas with chemical vapors. Inspect equipment after any period of
extended storage.
7.0
7.1
SPECIFICATIONS
MATERIAL:
8002001
8002002
8002003
8002004
8002005
8002006
8002008
8002009
8002010
Davit
Davit
Davit
Davit
Davit
Davit
Davit
Davit
Davit
Arm
Arm
Arm
Arm
Arm
Arm
Arm
Arm
Arm
Galvanized
Galvanized
Galvanized
Galvanized
Galvanized
Galvanized
Galvanized
Galvanized
Galvanized
19
steel,
steel,
steel,
steel,
steel,
steel,
steel,
steel,
steel,
anodized
anodized
anodized
anodized
anodized
anodized
anodized
anodized
anodized
aluminum
aluminum
aluminum
aluminum
aluminum
aluminum
aluminum
aluminum
aluminum
7.2
8004030
8002030
8002031
8002032
Davit
Davit
Davit
Davit
Arm
Arm
Arm
Arm
(Standard)
and Base
and Base
and Base
8002040
8002050
8003773
8003930
8004031
8004032
8004230
8004235
8004273
8004274
8004392
Davit Base
Davit Base
Davit Base
Portable Davit Base
Davit Base
Davit Base
Davit Base
Davit Base
Davit Base
Davit Base
Davit Base, Post style
Galvanized
Galvanized
Galvanized
Galvanized
steel,
steel,
steel,
steel,
anodized
anodized
anodized
anodized
aluminum
aluminum
aluminum
aluminum
Stainless steel
Stainless steel
Galvanized steel
Galvanized steel, anodized aluminum
Galvanized steel
Galvanized steel
Stainless steel
Galvanized steel
Stainless steel
Galvanized steel
Galvanized steel
APPLICATION SPECIFICATIONS:
8003930
8004031
8004032
41 lbs.
87 lbs.
49 lbs.
46 lbs.
73 lbs.
50 lbs.
81-90 inches
84 inches
85 inches
57 inches
24 inches
48 inches
36 inches
21 inches
16 inches
20 inches
5,000 lbs. all attachment points
20
8.0
LABELING
21
9.0
INSPECTION
ITEMS NOTED
CORRECTIVE
ACTION
Approved By:
Approved By:
Approved By:
Approved By:
Approved By:
Approved By:
Approved By:
Approved By:
Approved By:
Approved By:
Approved By:
22
MAINTENANCE
PERFORMED
WARRANTY
Equipment offered by DBI/SALA is warranted against factory defects in
workmanship and materials for a period of two years from date of installation
or use by the owner, provided that this period shall not exceed two years
from date of shipment. Upon notice in writing, DBI/SALA will promptly
repair or replace all defective items. DBI/SALA reserves the right to elect
to have any defective item returned to its plant for inspection before making
a repair or replacement. This warranty does not cover equipment damages
resulting from abuse, damage in transit, or other damage beyond the control
of DBI/SALA. This warranty applies only to the original purchaser and is
the only one applicable to our products, and is in lieu of all other warranties,
expressed or implied.
USA
Canada
I S O
9001
Certificate No. FM 39709
Form: 5902137
Rev: D