Está en la página 1de 639

Structural Design Software

Daniel Tian Li, Ph.D.


Structural Engineer (California, S.E. 4922)
Chartered Structural Engineer (United Kingdom, MIStructE 020283787)

Daniel T. Li, Engineering International Inc.


www.Engineering-International.com
128 E. Santa Clara St. Arcadia, CA 91006, USA

Neat clear Quick-Link.xlsm

Just input green values, don't have to know Excel

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Quick Open Link


PerforatedShearWall.xlsb
ShearWallOpening.xlsb
WoodColumn.xlsb
GreenCompositeWall.xlsb
WoodBeam.xlsb
CantileverBeam.xlsb
Diaphragm-Ledger-CMUWall.xlsb
DoubleJoist.xlsb
DragForces.xlsb
EquipmentAnchorage.xlsb
LagScrewsConnection.xlsb
Subdiaphragm.xlsb
ToeNail.xlsb
TopPlateConnection.xlsb
Truss-Wood.xlsb
WoodBoltConnection.xlsb
WoodDiaphragm.xlsb
WoodJoist.xlsb
WoodShearWall.xlsb
WoodTables.xlsb
TransferDiaphragm-Wood.xlsb
WoodPolePile.xlsb
WoodMember.xlsb
BendingPostAtColumn.xlsb
CurvedMember.xlsb
StrongCustomFrame.xlsb
CLT-TwoWayFloor.xlsb
HybridMember.xlsb
TwoWaySlab.xlsb
VoidedBiaxialSlabs.xlsb
AnchorageToConcrete.xlsb
AnchorageToPedestal.xlsb
CircularColumn.xlsb
ConcreteColumn.xlsb
SuperCompositeColumn.xlsb
SpecialShearWall-CBC.xlsb
OrdinaryShearWall.xlsb
ConcretePool.xlsb
Corbel.xlsb
CouplingBeam.xlsb
DeepBeam.xlsb
Non-DeepBeam.xlsb
DevelopmentSpliceConcrete.xlsb
EquipmentMounting.xlsb
ExistingShearWall.xlsb
Friction.xlsb
PipeConcreteColumn.xlsb
PT-ConcreteFloor.xlsb
Punching.xlsb
Slab.xlsb
VoidedSectionCapacity.xlsb
DiaphragmShear.xlsb
SMRF-ACI.xlsb
SpecialShearWall-IBC.xlsb
SuspendedAnchorage.xlsb
TiltupPanel.xlsb
Multi-StoryTilt-Up.xlsb
WallPier.xlsb
BeamPenetration.xlsb
ColumnSupportingDiscontinuous.xlsb
PlateShellElement.xlsb
TransferDiaphragm-Concrete.xlsb
Silo-Chimney-Tower.xlsb
ConcreteBeam.xlsb
AnchorageWithCircularBasePlate.xlsb
DirectCompositeBeam.xlsb
CompositeMomentConnection.xlsb
MetricBars.xlsb
BeamConnection.xlsb
AngleCapacity.xlsb
HSS-WF-Capacity.xlsb
MetalStuds.xlsb
SMRF-CBC.xlsb
SCBF-Parallel.xlsb
SCBF-Perpendicular.xlsb
ColumnAboveBeam.xlsb
BeamGravity.xlsb
BeamWithTorsion.xlsb
HSS-Torsion.xlsb
FixedBoltedJoint.xlsb
BraceConnection.xlsb
BRBF.xlsb
BSEP-SMF.xlsb
BoltedMomentConnection.xlsb

www.Engineering-International.com
Perforated Shear Wall Design Based on 2015 IBC / 2013 CBC / NDS 2015
Wood Shear Wall with an Opening Based on 2015 IBC / 2013 CBC / NDS 2015
Wood Post, Wall Stud, or King Stud Design Based on NDS 2015
Composite Strong Wall Design Based on ACI 318-14, AISI S100/SI-10 & ER-4943P
Wood Beam Design Based on NDS 2015
Wood Beam Design Based on NDS 2015
Connection Design for Wall & Diaphragm Based on 2015 IBC / 2013 CBC
Double Joist Design for Equipment Based on NDS 2015, ICC PFC-4354 & PFC-5803
Drag / Collector Force Diagram Generator
Equipment Anchorage to Wood Roof Based on NDS 2015 / 2015 IBC / 2013 CBC
Lag Screw Connection Design Based on NDS 2015
Subdiaphragm Design Based on ASCE 7-10
Toe-Nail Connection Design Based on NDS 2015
Top Plate Connection Design Based on NDS 2015
Wood Truss Design Based on NDS 2015
Bolt Connection Design Based on NDS 2015
Wood Diaphragm Design Based on NDS 2015
Wood Joist Design Based on NDS 2015 / NDS 01, ICC PFC-4354 & PFC-5803
Shear Wall Design Based on 2015 IBC / 2013 CBC / NDS 2015
Tables for Wood Post Design Based on NDS 2015
Wood Diaphragm Design for a Discontinuity of Type 4 out-of-plane offset irregularity
Wood Pole or Pile Design Based on NDS 2015
Wood Member (Beam, Column, Brace, Truss Web & Chord) Design Based on NDS 2015
Connection Design for Bending Post at Concrete Column Based on NDS 2015 & ACI 318-14
Curved Wood Member (Wood Torsion) Design Based on NDS 2015
4E-SMF with Wood Nailer Design Based on AISC 358-10 & NDS 2015
Two-Way Floor Design Based on NDS 2015, using Cross-Laminated Timber (CLT), by FEM
Hybrid Member (Wood & Metal) Design Based on NDS 2015, AISI S100 & ICBO ER-4943P
Two-Way Slab Design Based on ACI 318-14 using Finite Element Method
Voided Two-Way Slab Design Based on ACI 318-14
Base Plate and Group Anchors Design Based on ACI 318-14 & AISC 360-10
Anchorage to Pedestal Design Based on ACI 318-14 & AISC 360-10
Circular Column Design Based on ACI 318-14
Concrete Column Design Based on ACI 318-14
Super Composite Column Design Based on AISC 360-10 & ACI 318-14
Special Concrete Shear Wall Design Based on ACI 318-14 & 2013 CBC Chapter A
Ordinary Concrete Shear Wall Design Based on ACI 318-14
Concrete Pool Design Based on ACI 318-14
Corbel Design Based on IBC 09 / ACI 318-14
Coupling Beam Design Based on ACI 318-14
Deep Beam Design Based on ACI 318-14
Non Deep Beam Design Based on ACI 318-14
Development & Splice of Reinforcement Based on ACI 318-14
Design for Equipment Anchorage Based on 2015 IBC & 2013 CBC Chapter A
Verify Existing Concrete Shear Wall Based on ASCE 41-06 / 2013 CBC & 2015 IBC
Shear Friction Reinforcing Design Based on ACI 318-14
Pipe Concrete Column Design Based on ACI 318-14
Design of Post-Tensioned Concrete Floor Based on ACI 318-14
Slab Punching Design Based on ACI 318-14
Concrete Slab Perpendicular Flexure & Shear Capacity Based on ACI 318-14
Voided Section Design Based on ACI 318-14
Concrete Diaphragm in-plane Shear Design Based on ACI 318-14
Seismic Design for Special Moment Resisting Frame Based on ACI 318-14
Special Reinforced Concrete Shear Wall Design Based on ACI 318-14 & 2015 IBC
Suspended Anchorage to Concrete Based on 2015 IBC & 2013 CBC
Tilt-up Panel Design based on ACI 318-14
Multi-Story Tilt-Up Wall Design Based on ACI 318-14
Wall Pier Design Based on 2013 CBC & 2015 IBC
Design for Concrete Beam with Penetration Based on ACI 318-14
Column Supporting Discontinuous System Based on ACI 318-14
Plate/Shell Element Design Based on ACI 318-14
Concrete Diaphragm Design for a Discontinuity of Type 4 out-of-plane offset irregularity
Concrete Silo / Chimney / Tower Design Based on ASCE 7-10, ACI 318-14 & ACI 313-97
Concrete Beam Design, for New or Existing, Based on ACI 318-14
Anchorage Design, with Circular Base Plate, Based on ACI 318-14 & AISC 360-10
Composite Beam/Collector Design, without Metal Deck, Based on AISC 360-10 & ACI 318-14
Composite Moment Connection Design Based on ACI 318-14
Flexural & Axial Design for Custom Metric Bars Based on Linear Distribution of Strain
Beam Connection Design Based on AISC 360-2010 (AISC 360-10)
Angle Steel Member Capacity Based on AISC 360-10
Tube, Pipe, or WF Member Capacity Based on AISC 360-10
Metal Member Design Based on AISI S100-07/SI-10 (2015 IBC) & ICBO ER-4943P
Seismic Design for Special Moment Resisting Frames Based on 2013 CBC
Seismic Design for Special Concentrically Braced Frames Based on CBC/IBC & AISC 341-10
Bracing Connection Design, with Perpendicular Gusset, Based on CBC/IBC & AISC 341-10
Connection Design for Column above Beam, Based on AISC Manual & AISC 360-10
Steel Gravity Beam Design Based on AISC Manual 13th Edition (AISC 360-10)
WF Simply Supported Beam Design with Torsional Loading Based on AISC 360-10
HSS (Tube, Pipe) Member Design with Torsional Loading Based on AISC 360-10
Fixed Bolted Joint, with Beam Sitting on Top of Column, Based on AISC 358-10 8ES/4ES & FEMA-350
Typical Bracing Connection Capacity Based on AISC 360-10
Buckling-Restrained Braced Frames Based on AISC 360-10 & AISC 341-10
Bolted Seismic Moment Connection Based on AISC 341-10, 358-10, 360-10 & FEMA-350
Bolted Non-Seismic Moment Connection Based on AISC 341-10, 358-10, 360-10 & FEMA-350

Group
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Wood
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Concrete
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel

Last Updated
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/12/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
5/21/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015

17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33

ChannelCapacity.xlsb
CompositeCollectorBeam.xlsb
CompositeFloorBeam.xlsb
CompositeFloorBeamWithCantilever.xlsb
CompositeFloorGirder.xlsb
DragConnection.xlsb
DragForcesforBraceFrame.xlsb
EBF-CBC.xlsb
EBF-IBC.xlsb
EnhancedCompositeBeam.xlsb
EnhancedSteelBeam.xlsb
ExteriorMetalStudWall.xlsb
FloorDeck.xlsb
GussetGeometry.xlsb
MetalShearWall.xlsb
MetalShearWallOpening.xlsb
Metal-Z-Purlins.xlsb
OCBF-CBC.xlsb
OCBF-IBC.xlsb
CantileverFrame.xlsb
OMRF-CBC.xlsb
OMRF-IBC.xlsb
PlateGirder.xlsb
RectangularSection.xlsb
RoofDeck.xlsb
BasePlate.xlsb
SMRF-IBC.xlsb
SPSW.xlsb
SteelColumn.xlsb
SteelStair.xlsb
TripleW-Shapes.xlsb
PortalFrame.xlsb
WebTaperedPortal.xlsb
WebTaperedFrame.xlsb
WebTaperedGirder.xlsb
WeldConnection.xlsb
WF-Opening.xlsb
MomentAcrossGirder.xlsb
BeamSplice.xlsb
FilledCompositeColumn.xlsb
CellularBeam.xlsb
DoubleAngleCapacity.xlsb
T-ShapeCapacity.xlsb
CantileverColumn.xlsb
Truss-Metal.xlsb
SleeveJointConnection.xlsb
MomentToColumnWeb.xlsb
ConXL.xlsb
ThinCompositeBeam.xlsb
BoltConnection.xlsb
SCCS-OCCS.xlsb
Non-PrismaticCompositeGirder.xlsb
Wind-ASCE7-10.xlsb
Seismic-2015IBC.xlsb
Wind-ASCE7-05.xlsb
PipeRiser.xlsb
RigidDiaphragm.xlsb
FlexibleDiaphragm.xlsb
TwoStoryMomentFrame.xlsb
X-BracedFrame.xlsb
OpenStructureWind.xlsb
RoofScreenWind.xlsb
AxialRoofDeck.xlsb
DeformationCompatibility.xlsb
DiscontinuousShearWall.xlsb
FlexibleDiaphragmOpening.xlsb
Handrail.xlsb
InteriorWallLateralForce.xlsb
LateralFrameFormulas.xlsb
LiveLoad.xlsb
Seismic-SingleFamilyDwellings.xlsb
ShadeStructureWind.xlsb
ShearWallForces.xlsb
ShearWall-NewOpening.xlsb
ShearWallRigidity.xlsb
Sign.xlsb
SignWind.xlsb
Snow.xlsb
WallLateralForce-CBC.xlsb
WallLateralForce-IBC.xlsb
Seismic-IBC2009.xlsb
WindGirtDeflection.xlsb
StorageRacks.xlsb
Wind-Alternate.xlsb
CeilingSeismic.xlsb

Channel Steel Member Capacity Based on AISC 360-10


Composite Collector Beam with Seismic Loads Based on 2013 CBC / 2015 IBC
Composite Beam Design Based on AISC Manual 9th
Composite Beam Design Based on AISC 360-10 / 2015 IBC / 2013 CBC
Composite Girder Design Based on AISC 360-10 / 2015 IBC / 2013 CBC
Drag Connection Based on AISC 360-10 & AISC 341-10
Drag / Collector Forces for Brace Frame
Seismic Design for Eccentrically Braced Frames Based on 2013 CBC & AISC 341-10
Seismic Design for Eccentrically Braced Frames Based on 2015 IBC & AISC 341-10
Enhanced Composite Beam Design Based on AISC 360-10 / 2015 IBC / 2013 CBC
Enhanced Steel Beam Design Based on AISC 14th (AISC 360-10)
Exterior Metal Stud Wall Design Based on AISI S100-07/SI-10 & ER-4943P
Depressed Floor Deck Capacity (Non-Composite)
Gusset Plate Dimensions Generator
Metal Shear Wall Design Based on AISI S100-07/SI-10, ER-5762 & ER-4943P
Metal Shear Wall with an Opening Based on AISI S100-07/SI-10, ER-5762 & ER-4943P
Metal Z-Purlins Design Based on AISI S100-07/SI-10
Ordinary Concentrically Braced Frames Based on 2013 CBC & AISC 341-10
Ordinary Concentrically Braced Frames Based on 2015 IBC & AISC 341-10
Web-Tapered Cantilever Frame Design Based on AISC-ASD 9th, Appendix F
Intermediate/Ordinary Moment Resisting Frames Based on 2013 CBC
Intermediate/Ordinary Moment Resisting Frames Based on 2015 IBC
Plate Girder Design Based on AISC Manual 14th Edition (AISC 360-10)
Rectangular Section Member Design Based on AISC 360-10
Design of 1 1/2" Type "B" Roof Deck Based on ICBO ER-2078P
Base Plate Design Based on AISC Manual 13th Edition (AISC 360-10)
Special Moment Resisting Frames Based on 2015 IBC, AISC 341-10 & AISC 358-10
Seismic Design for Special Plate Shear Wall Based on AISC 341-10 & AISC 360-10
Steel Column Design Based on AISC Manual 13th Edition (AISC 360-10)
Steel Stair Design Based on AISC 360-10
Simply Supported Member of Triple W-Shapes Design Based on AISC 360-10
Portal Frame Analysis using Finite Element Method
Web Tapered Portal Based on AISC-ASD 9th Appendix F and/or AISC Design Guide 25
Web Tapered Frame Based on AISC-ASD 9th Appendix F and/or AISC Design Guide 25
Web Tapered Girder Design Based on AISC-ASD 9th Appendix F and/or AISC Design Guide 25
Weld Connection Design Based on AISC 360-10
Check Capacity of WF Beam at Opening Based on AISC 360-10
Design for Fully Restrained Moment Connection across Girder Based on AISC 360-10
Beam Bolted Splice Design Based on AISC Manual 13th Edition (AISC 360-10)
Filled Composite Column Design Based on AISC 360-10 & ACI 318-14
Cellular Beam Design Based on AISC 360-10
Double Angle Capacity Based on AISC 360-10
T-Shape Member Capacity Based on AISC 360-10
Cantilever Column & Footing Design Based on AISC 360-10, ACI 318-14, and IBC 1807.3
Light Gage Truss Design Based on AISI S100-07/SI-10 & ER-4943P
Sleeve Joint Connection Design, for Steel Cell Tower / Sign, Based on AISC 360-10
Moment Connection Design for Beam to Weak Axis Column Based on AISC 360-10
Seismic Bi-axial Moment Frame Design Based on AISC 358-10 & ACI 318-14
Thin Composite Beam/Collector Design Based on AISC 360-10 & ACI 318-14
Bolt Connection Design Based on AISC Manual 14th Edition (AISC 360-10)
Cantilever Column System (SCCS/OCCS) Design Based on AISC 341-10/360-10 & ACI 318-14
Non-Prismatic Composite Girder Design Based on AISC 360-10 / 2013 CBC / 2015 IBC
Wind Analysis Based on ASCE 7-10
Seismic Analysis Based on ASCE 7-10
Wind Analysis Based on ASCE 7-05, Including Roof Solar Panel Loads
MCE Level Seismic Design for Metal Pipe/Riser Based on ASCE 7-10 & AISI S100
Rotation Analysis of Rigid Diaphragm Based on 2015 IBC / 2013 CBC
Flexible Diaphragm Analysis
Two Story Moment Frame Analysis using Finite Element Method
X-Braced Frame Analysis using Finite Element Method
Wind Analysis for Open Structure (Solar Panels) Based on ASCE 7-10 & 05
Wind Load, on Roof Screen / Roof Equipment, Based on ASCE 7-10 & 05
Axial Capacity of 1 1/2" Type "B" Roof Deck Based on ICBO ER-2078P
Column Deformation Compatibility Design using Finite Element Method
Discontinuous Shear Wall Analysis Using Finite Element Method
Flexible Diaphragm with an Opening Analysis
Handrail Design Based on AISC 360-10 & ACI 318-14
Interior Wall Lateral Forces Based on 2015 IBC / 2013 CBC
Lateral Frame Formulas
Live Load Reduction Based on ASCE 7-10, 2015 IBC / 2013 CBC
Seismic Analysis for Family Dwellings Based on 2015 IBC / 2013 CBC
Wind Analysis for Shade Open Structure Based on ASCE 7-10 & 05
Shear Wall Analysis for Shear Wall with Opening Using Finite Element Method
Relative Rigidity Determination for Shear Wall with New Opening
Rigidity for Shear Wall & Shear Wall with Opening Using Finite Element Method
Sign Design Based on AISC 360-10, ACI 318-14, and IBC 1807.3
Wind Analysis for Freestanding Wall & Sign Based on ASCE 7-10 & 05
Snow Load Analysis Based on ASCE 7-10, 05, & UBC
Lateral Force for One-Story Wall Based on 2013 CBC
Lateral Force for One-Story Wall Based on 2015 IBC
Seismic Analysis Based on 2009 IBC / 2010 CBC
Wind Girt Deflection Analysis of Wood, Metal Stud, and/or Steel Tube
Lateral Loads of Storage Racks, with Hilti & Red Head Anchorage, Based on ASCE 7-10
Wind Analysis for Alternate All-Heights Method, Based on ASCE 7-10
Suspended Ceiling Seismic Loads Based on ASCE 7-10

Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral

8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/12/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015

34
35
36
37
38
39
40
41
42
43
44
45
46
1
2
3
4
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
1
2
3
4
5
6
7
8

ResponseSpectrumGenerator.xlsb
Tornado-Hurricane.xlsb
StiffnessMatrix.xlsb
PT-ColumnDrift.xlsb
BlastMitigation.xlsb
Wind-SEAOC-PV2.xlsb
Seismic-vs-Wind.xlsb
SC-Frame.xlsb
UnitConversion.xlsb
GeneralBeam.xlsb
Wind-TrussedTower.xlsb
PT-Frame.xlsb
External-PT-Beam.xlsb
Aluminum-I-WF-Capacity.xlsb
Aluminum-C-CS-Capacity.xlsb
Aluminum-RT-Capacity.xlsb
Aluminum-PIPE-Capacity.xlsb
StructuralGlass.xlsb
FreeStandingWall.xlsb
EccentricFooting.xlsb
Flagpole.xlsb
MasonryRetainingWall.xlsb
ConcreteRetainingWall.xlsb
Masonry-Concrete-RetainingWall.xlsb
ConcretePier.xlsb
ConcretePile.xlsb
PileCaps.xlsb
PileCapBalancedLoads.xlsb
ConventionalSlabOnGrade.xlsb
PT-SlabOnGround.xlsb
BasementConcreteWall.xlsb
BasementMasonryWall.xlsb
BasementColumn.xlsb
MRF-GradeBeam.xlsb
BraceGradeBeam.xlsb
GradeBeam.xlsb
CircularFooting.xlsb
CombinedFooting.xlsb
BoundarySpringGenerator.xlsb
DeepFooting.xlsb
FootingAtPiping.xlsb
IrregularFootingSoilPressure.xlsb
PAD.xlsb
PlainConcreteFooting.xlsb
RestrainedRetainingWall.xlsb
RetainingWall-DSA-OSHPD.xlsb
TankFooting.xlsb
TemporaryFootingforRectangularTank.xlsb
UnderGroundWell.xlsb
StudBearingWallFooting.xlsb
WallFooting.xlsb
FixedMomentCondition.xlsb
FloodWay.xlsb
LateralEarthPressure.xlsb
Shoring.xlsb
CompositeElementDurability.xlsb
MasonryShearWall-CBC.xlsb
MasonryShearWall-IBC.xlsb
AnchorageToMasonry.xlsb
FlushWallPilaster-CBC.xlsb
FlushWallPilaster-IBC.xlsb
BearingWallOpening.xlsb
BendingPostAtTopWall.xlsb
DevelopmentSpliceMasonry.xlsb
Elevator-DSA-OSHPD.xlsb
GirderAtWall.xlsb
HorizontalBendingWall.xlsb
MasonryBeam.xlsb
MasonryBearingWall-CBC.xlsb
MasonryBearingWall-IBC.xlsb
MasonryColumn-CBC.xlsb
MasonryColumn-IBC.xlsb
BeamToWall.xlsb
CollectorToWall.xlsb
HybridMasonry.xlsb
PT-MasonryShearWall.xlsb
MasonryWallOpening.xlsb
Arch-Bridge.xlsb
Bridge-ConcreteGirder.xlsb
Bridge-ConcreteColumn.xlsb
Bridge-BoxSection.xlsb
ConcreteTunnel.xlsb
DoubleTee.xlsb
BoxCulvert.xlsb
SteelRoadPlate.xlsb

Earthquake Response Spectrum Generator


Wind Analysis for Tornado and Hurricane Based on 2015 IBC Section 423 & FEMA 361/320
Stiffness Matrix Generator for Irregular Beam/Column
Lateral Drift Mitigation for Cantilever Column using Post-Tensioning
Blast Deformation Mitigation for Gravity Column using Post-Tensioning
Wind Design for Low-Profile Solar Photovoltaic Arrays on Flat Roof, Based on SEAOC PV2-2012
Three, Two, and One Story Comparison of Seismic and Wind Based on 2015 IBC / 2013 CBC
Self-Centering Lateral Frame Design Based on ASCE 7-10, AISC 360-10 & ACI 318-14
Unit Conversions between U.S. Customary System & Metric System
General Beam Analysis
Wind Analysis for Trussed Tower Based on ASCE 7-10
Post-Tensioned Lateral Frame Analysis using Finite Element Method
Beam Strengthening Analysis Using External Post-Tensioning Systems
Aluminum I or WF Member Capacity Based on Aluminum Design Manual 2010 (ADM-I)
Aluminum C or CS Member Capacity Based on Aluminum Design Manual 2010 (ADM-I)
Aluminum RT Member Capacity Based on Aluminum Design Manual 2010 (ADM-I)
Aluminum PIPE Member Capacity Based on Aluminum Design Manual 2010 (ADM-I)
Glass Wall/Window/Stair Design, Based on ASTM E1300, using Finite Element Method
Free Standing Masonry & Conctere Wall Design Based on TMS 402-11/13 & ACI 318-14
Eccentric Footing Design Based on ACI 318-14
Flagpole Footing Design Based on Chapter 18 of IBC & CBC
Masonry Retaining / Fence Wall Design Based on TMS 402-11/13 & ACI 318-14
Concrete Retaining Wall Design Based on ACI 318-14
Retaining Wall Design, for Masonry Top & Concrete Bottom, Based on TMS 402-11/13 & ACI 318-14
Concrete Pier (Isolated Deep Foundation) Design Based on ACI 318-14
Drilled Cast-in-place Pile Design Based on ACI 318-14
Pile Cap Design for 4, 3, 2-Piles Pattern Based on ACI 318-14
Determination of Pile Cap Balanced Loads and Reactions
Design of Conventional Slabs on Expansive & Compressible Soil Grade Based on ACI 360
Design of PT Slabs on Expansive & Compressible Soil Based on PTI 3rd Edition
Basement Concrete Wall Design Based on ACI 318-14
Basement Masonry Wall Design Based on TMS 402-11/13
Basement Column Supporting Lateral Resisting Frame Based on ACI 318-14
Grade Beam Design for Moment Resisting Frame Based on ACI 318-10
Grade Beam Design for Brace Frame Based on ACI 318-14
Two Pads with Grade Beam Design Based on ACI 318-14 & AISC 360-10
Circular Footing Design Based on ACI 318-14
Combined Footing Design Based on ACI 318-14
Mat Boundary Spring Generator
Deep Footing Design Based on ACI 318-14
Design of Footing at Piping Based on ACI 318-14
Soil Pressure Determination for Irregular Footing
Pad Footing Design Based on ACI 318-14
Plain Concrete Footing Design Based on ACI 318-14
Restrained Retaining Masonry & Concrete Wall Design Based on TMS 402 & ACI 318
Retaining Wall Design Based on 2013 CBC Chapter A
Tank Footing Design Based on ACI 318-14
Temporary Tank Footing Design Based on ACI 318-14
Under Ground Well Design Based on ACI 350-06 & ACI 318-14
Footing Design for Stud Bearing Wall Based on 2015 IBC / ACI 318-14
Footing Design of Shear Wall Based on ACI 318-14
Fixed Moment Condition Design Based on ACI 318-14
Concrete Floodway Design Based on ACI 350-06 & ACI 318-14
Lateral Earth Pressure of Rigid Wall Based on AASHTO 17th & 2015 IBC
Sheet Pile Wall Design Based on 2015 IBC / 2013 CBC / ACI 318-14
Composite Element Design Based on AISC 360-10 & ACI 318-14
Masonry Shear Wall Design Based on 2013 CBC Chapter A (both ASD and SD)
Masonry Shear Wall Design Based on TMS 402-11/13 & 2015 IBC (both ASD and SD)
Fastener Anchorage Design in Masonry Based on TMS 402-11/13 & 2015 IBC
Masonry Flush Wall Pilaster Design Based on 2013 CBC Chapter A
Masonry Flush Wall Pilaster Design Based on TMS 402-11/13 & 2015 IBC
Design of Masonry Bearing Wall with Opening Based on TMS 402-11/13
Design for Bending Post at Top of Wall, Based on TMS 402-11/13
Development & Splice of Reinforcement in Masonry Based on TMS 402-11/13 & 2015 IBC & 2013 CBC
Elevator Masonry Wall Design Based on 2013 CBC Chapter A & 2015 IBC
Design for Girder at Masonry Wall Based on TMS 402-11/13
Masonry Wall Design at Horizontal Bending Based on TMS 402-11/13
Masonry Beam Design Based on TMS 402-11/13
Allowable & Strength Design of Masonry Bearing Wall Based on 2013 CBC Chapter A
Allowable & Strength Design of Masonry Bearing Wall Based on TMS 402-11/13 & 2015 IBC
Masonry Column Design Based on 2013 CBC Chapter A
Masonry Column Design Based on TMS 402-11/13 & 2015 IBC
Beam to Wall Anchorage Design Based on TMS 402-11/13 & 2015 IBC
Collector to Wall Connection Design Based on TMS 402-11/13 & 2015 IBC
Hybrid Masonry Wall Design Based on TMS 402-11/13
Post-Tensioned Masonry Shear Wall Design Based on TMS 402-11/13 (SD Method)
Masonry Shear Wall with Opening Design Using Finite Element Method
Arch Bridge Analysis using Finite Element Method
Prestressed Concrete Girder Design for Bridge Structure Based on AASHTO 17th Edition & ACI 318-14
Bridge Column Design Based on AASHTO 17th & ACI 318-14
Bridge Design for Prestressed Concrete Box Section Based on AASHTO 17th Edition & ACI 318-14
Concrete Tunnel Design Based on AASHTO-17th & ACI 318-14
Prestressed Double Tee Design Based on AASHTO 17th Edition & ACI 318-14
Concrete Box Culvert Design Based on AASHTO 17th Edition & ACI 318-14
Steel Road Plate Design Based on AASHTO 17th Edition & AISC 360-10 using Finite Element Method

Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Lateral
Aluminum
Aluminum
Aluminum
Aluminum
Aluminum
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Foundation
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Bridge
Bridge
Bridge
Bridge
Bridge
Bridge
Bridge
Bridge

8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
8/4/2015
11/1/2013
11/1/2013
11/1/2013
11/1/2013
11/1/2013
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
5/23/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
7/14/2015
5/14/2015
5/14/2015
5/14/2015
5/14/2015
5/14/2015
5/14/2015
5/14/2015
5/14/2015

9
10
11
12
13
14

FlangeTaperedGirder.xlsb
PrestressedConcreteCircularHollowSection.xlsb
Falsework.xlsb
PolygonCapacity.xlsb
Truss-Bridge.xlsb
ConcreteWall-Mount.xlsb

Flange Tapered Plate Girder Design Based on AISC Manual 14th Edition (AISC 360-10)
Prestressed Concrete Circular Hollow Pole/Pile Design Based on ACI 318-14 & AASHTO 17th
Falsework Design for Steel Girder Bridge Based on NDS 2015 & AASHTO 17th
Polygon Section Member (Tubular Steel Pole) Design Based on ASCE 48-14
Truss Analysis using Finite Element Method
Mounting Design on Concrete Wall/Tunnel Based on FEMA E-74, 2015 IBC, and 2013 CBC Chapter A

Bridge
Bridge
Bridge
Bridge
Bridge
Bridge

5/14/2015
5/14/2015
5/14/2015
5/14/2015
5/14/2015
5/14/2015

Structural Design Software

Page 1 of 4

STRUCTURAL DESIGN SOFTWARE


Foundation

Lateral

Concrete

Steel

Aluminum & Glass

Masonry

Bridge

Wood

Technical Support

This web site provides structural design software which created using Microsoft Windows Excel 2010/2013. Each spreadsheet contains formulas, reference code sections, and graphic drawings. The
software are nice and easy on all Win Tablet/PAD. The analysis results can be copied and pasted to AutoCAD. The Example is intended for re-use and is loaded with floating comments as well as
ActiveX pull-down menus for variable choices. All intermediate calculations are intended for submittal with the calculations to explain the results of the input. It is free to download, by click software
name, for limited version (demo only). For professional version (xlsb/xls filename extension), a Package of all 260 listed software, the normal price is $1760 (less than $7 per software).
(What's New?)

(User's Book)

(Unit Conversions)

Masonry Design Group


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Masonry Shear Wall - CBC


Masonry Shear Wall - IBC
Anchorage to Masonry
Flush Wall Pilaster - CBC
Flush Wall Pilaster - IBC
Bearing Wall Opening
Bending Post at Top Wall
Development Splice Masonry
Elevator for DSA / OSHPD
Girder at Wall
Horizontal Bending Wall
Masonry Beam
Masonry Bearing Wall - CBC
Masonry Bearing Wall - IBC
Masonry Column - CBC
Masonry Column - IBC
Beam to Wall
Collector to Wall
Hybrid Masonry Wall
PT-Masonry Shear Wall
Masonry Shear Wall Opening

Masonry Shear Wall Design Based on 2013 CBC Chapter A (both ASD and SD)
Masonry Shear Wall Design Based on TMS 402-11/13 & 2015 IBC (both ASD and SD)
Fastener Anchorage Design in Masonry Based on TMS 402-11/13 & 2015 IBC
Masonry Flush Wall Pilaster Design Based on 2013 CBC Chapter A
Masonry Flush Wall Pilaster Design Based on TMS 402-11/13 & 2015 IBC
Design of Masonry Bearing Wall with Opening Based on TMS 402-11/13
Design for Bending Post at Top of Wall, Based on TMS 402-11/13
Development & Splice of Reinforcement in Masonry Based on TMS 402-11/13 & 2015 IBC & 2013 CBC
Elevator Masonry Wall Design Based on 2013 CBC Chapter A & 2015 IBC
Design for Girder at Masonry Wall Based on TMS 402-11/13
Masonry Wall Design at Horizontal Bending Based on TMS 402-11/13
Masonry Beam Design Based on TMS 402-11/13
Allowable & Strength Design of Masonry Bearing Wall Based on 2013 CBC Chapter A
Allowable & Strength Design of Masonry Bearing Wall Based on TMS 402-11/13 & 2015 IBC
Masonry Column Design Based on 2013 CBC Chapter A
Masonry Column Design Based on TMS 402-11/13 & 2015 IBC
Beam to Wall Anchorage Design Based on TMS 402-11/13 & 2015 IBC
Collector to Wall Connection Design Based on TMS 402-11/13 & 2015 IBC
Hybrid Masonry Wall Design Based on TMS 402-11/13
Post-Tensioned Masonry Shear Wall Design Based on TMS 402-11/13 (LEED Gold)
Masonry Shear Wall with Opening Design Using Finite Element Method

Aluminum & Glass Design


1
2
3
4
5

Aluminum I or WF Member
Aluminum C or CS Member
Aluminum RT Member
Aluminum PIPE Member
Structural Glass

Aluminum I or WF Member Capacity Based on Aluminum Design Manual 2010 (ADM-I)


Aluminum C or CS Member Capacity Based on Aluminum Design Manual 2010 (ADM-I)
Aluminum RT Member Capacity Based on Aluminum Design Manual 2010 (ADM-I)
Aluminum PIPE Member Capacity Based on Aluminum Design Manual 2010 (ADM-I)
Glass Wall/Window/Stair Design, Based on ASTM E1300, using Finite Element Method

Concrete Design Group


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Custom Metric Bars


Voided Biaxial Slab
Anchorage to Concrete
Anchorage to Pedestal
Circular Column
Concrete Column
Super Composite Column
Special Shear Wall - CBC
Ordinary Shear Wall
Concrete Pool
Corbel
Coupling Beam
Deep Beam
Non Deep Beam
Equipment Mounting
Existing Shear Wall
Friction
Pipe Concrete Column
PT-Concrete Floor
Punching
Concrete Slab
Voided Section Capacity
Concrete Diaphragm
SMRF - ACI
Special Shear Wall - IBC
Suspended Anchorage
Tiltup Panel
Wall Pier
Beam Penetration
Column Supporting Discontinuous
Plate Shell Element
Transfer Diaphragm - Concrete
Silo/Chimney/Tower Design
Concrete Beam
Anchorage with Circular Base Plate
Direct Composite Beam
Multi-Story Tilt-Up
Composite Moment Connection
Concrete Development & Splice
Two Way Slab

Flexural & Axial Design for Custom Metric Bars Based on Linear Distribution of Strain
Voided Two-Way Slab Design Based on ACI 318-14
Base Plate and Group Anchors Design Based on ACI 318-14 & AISC 360-10
Anchorage to Pedestal Design Based on ACI 318-14 & AISC 360-10
Circular Column Design Based on ACI 318-14
Concrete Column Design Based on ACI 318-14
Super Composite Column Design Based on AISC 360-10 & ACI 318-14
Special Concrete Shear Wall Design Based on ACI 318-14 & 2013 CBC Chapter A
Ordinary Concrete Shear Wall Design Based on ACI 318-14
Concrete Pool Design Based on ACI 318-14
Corbel Design Based on 2015 IBC / ACI 318-14
Coupling Beam Design Based on ACI 318-14
Deep Beam Design Based on ACI 318-14
Non Deep Beam Design Based on ACI 318-14
Design for Equipment Anchorage Based on ASCE 7-10 Supplement 1 & 2013 CBC Chapter A
Verify Existing Concrete Shear Wall Based on ASCE 41-06 / 2013 CBC / 2015 IBC
Shear Friction Reinforcing Design Based on ACI 318-14
Pipe Concrete Column Design Based on ACI 318-14
Design of Post-Tensioned Concrete Floor Based on ACI 318-14
Slab Punching Design Based on ACI 318-14
Concrete Slab Perpendicular Flexure & Shear Capacity Based on ACI 318-14
Voided Section Design Based on ACI 318-14
Concrete Diaphragm in-plane Shear Design Based on ACI 318-14
Seismic Design for Special Moment Resisting Frame Based on ACI 318-14
Special Reinforced Concrete Shear Wall Design Based on ACI 318-14 & 2015 IBC
Suspended Anchorage to Concrete Based on 2015 IBC & 2013 CBC
Tilt-up Panel Design based on ACI 318-14
Wall Pier Design Based on 2013 CBC & 2015 IBC
Design for Concrete Beam with Penetration Based on ACI 318-14
Column Supporting Discontinuous System Based on ACI 318-14
Plate/Shell Element Design Based on ACI 318-14
Concrete Diaphragm Design for a Discontinuity of Type 4 out-of-plane offset irregularity
Concrete Silo / Chimney / Tower Design Based on ASCE 7-10, ACI 318-14 & ACI 313-97
Concrete Beam Design, for New or Existing, Based on ACI 318-14
Anchorage Design, with Circular Base Plate, Based on ACI 318-14 & AISC 360-10
Composite Beam/Collector Design, without Metal Deck, Based on AISC 360-10 & ACI 318-14
Multi-Story Tilt-Up Wall Design Based on ACI 318-14
Composite Moment Connection Design Based on ACI 318-14
Development & Splice of Reinforcement Based on ACI 318-14
Two-Way Slab Design Based on ACI 318-14 using Finite Element Method

Wood Design Group


1
2
3
4
5
6
7

CLT Two Way Floor


Wood Pole Pile
Perforated Shear Wall
Shear Wall Opening
Wood Beam
Cantilever Beam
Diaphragm-Ledger-CMU Wall

Two-Way Floor Design Based on NDS 2015, using Cross-Laminated Timber (CLT), by FEM
Wood Pole or Pile Design Based on NDS 2015
Perforated Shear Wall Design Based on 2015 IBC / 2013 CBC / NDS 2015
Wood Shear Wall with an Opening Based on 2015 IBC / 2013 CBC / NDS 2015
Wood Beam Design Based on NDS 2015
Wood Beam Design Based on NDS 2015
Connection Design for Wall & Diaphragm Based on 2015 IBC / 2013 CBC

http://www.engineering-international.com/

8/12/2015

Structural Design Software

8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Double Joist
Drag Forces
Equipment Anchorage
Lag Screws Connection
Subdiaphragm
Toe Nail
Top Plate Connection
Wood Truss
Wood Bolt Connection
Wood Diaphragm
Wood Joist
Wood Shear Wall
Wood Design Tables
Transfer Diaphragm - Wood
Wood Column
Green Composite Wall
Bending Post at Column
Curved Member
Wood Member
Strong Custom Frame
Hybrid Member

Page 2 of 4

Double Joist Design for Equipment Based on NDS 2015, ICC PFC-4354 & PFC-5803
Drag / Collector Force Diagram Generator
Equipment Anchorage to Wood Roof Based on NDS 2015 / 2015 IBC / 2013 CBC
Lag Screw Connection Design Based on NDS 2015
Subdiaphragm Design Based on ASCE 7-10
Toe-Nail Connection Design Based on NDS 2015
Top Plate Connection Design Based on NDS 2015
Wood Truss Design Based on NDS 2015
Bolt Connection Design Based on NDS 2015
Wood Diaphragm Design Based on NDS 2015
Wood Joist Design Based on NDS 2015 / NDS 01, ICC PFC-4354 & PFC-5803
Shear Wall Design Based on 2015 IBC / 2013 CBC / NDS 2015
Tables for Wood Post Design Based on NDS 2015
Wood Diaphragm Design for a Discontinuity of Type 4 out-of-plane offset irregularity
Wood Post, Wall Stud, or King Stud Design Based on NDS 2015
Composite Strong Wall Design Based on ACI 318-14, AISI S100/SI-10 & ER-4943P
Connection Design for Bending Post at Concrete Column Based on NDS 2015 & ACI 318-14
Curved Wood Member (Wood Torsion) Design Based on NDS 2015
Wood Member (Beam, Column, Brace, Truss Web & Chord) Design Based on NDS 2015
4E-SMF with Wood Nailer Design Based on AISC 358-10 & NDS 2015
Hybrid Member (Wood & Metal) Design Based on NDS 2015, AISI S100 & ICBO ER-4943P

Bridge Design Group


1
2
3
4
5
6
7
8
9
10
11
12
13
14

Arch Bridge
Bridge Concrete Column
Bridge Box Section
Concrete Tunnel
Double Tee
Concrete Box Culvert
Steel Road Plate
Flange Tapered Girder
Prestressed Concrete Pole/Pile
Falsework
Polygon Capacity
Concrete Wall-Mount
Truss Bridge
Bridge Concrete Girder

Arch Bridge Analysis using Finite Element Method


Bridge Column Design Based on AASHTO 17th & ACI 318-14
Bridge Design for Prestressed Concrete Box Section Based on AASHTO 17th Edition & ACI 318-14
Concrete Tunnel Design Based on AASHTO-17th & ACI 318-14
Prestressed Double Tee Design Based on AASHTO 17th Edition & ACI 318-14
Concrete Box Culvert Design Based on AASHTO 17th Edition & ACI 318-14
Steel Road Plate Design Based on AASHTO 17th Edition & AISC 360-10 using Finite Element Method
Flange Tapered Plate Girder Design Based on AISC Manual 14th Edition (AISC 360-10)
Prestressed Concrete Circular Hollow Pole/Pile Design Based on ACI 318-14 & AASHTO 17th
Falsework Design for Steel Girder Bridge Based on NDS 2015 & AASHTO 17th
Polygon Section Member (Tubular Steel Pole) Design Based on ASCE 48-14
Mounting Design on Concrete Wall/Tunnel Based on FEMA E-74, 2015 IBC, and 2013 CBC Chapter A
Truss Analysis using Finite Element Method
Prestressed Concrete Girder Design for Bridge Structure Based on AASHTO 17th Edition & ACI 318-14

Foundation Design Group


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38

Free Standing Wall


Eccentric Footing
Flagpole
Masonry Retaining Wall
Concrete Retaining Wall
Masonry-Concrete Retaining Wall
Concrete Pier
Concrete Pile
Pile Caps
Pile Cap Balanced Loads
Conventional Slab on Grade
PT-Slab on Ground
Basement Concrete Wall
Basement Masonry Wall
Basement Column
MRF-Grade Beam
Brace Grade Beam
Grade Beam
Circular Footing
Combined Footing
Boundary Spring Generator
Deep Footing
Footing at Piping
Irregular Footing Soil Pressure
PAD Footing
Plain Concrete Footing
Restrained Retaining Wall
Retaining Wall for DSA /OSHPD
Tank Footing
Temporary Footing for Rectangular Tank
Under Ground Well
Stud Bearing Wall Footing
Wall Footing
Fixed Moment Condition
Flood Way
Lateral Earth Pressure
Shoring
Composite Element Durability

Free Standing Masonry & Conctere Wall Design Based on TMS 402-11/13 & ACI 318-14
Eccentric Footing Design Based on ACI 318-14
Flagpole Footing Design Based on 2015 IBC Chapter 18
Masonry Retaining / Fence Wall Design Based on TMS 402-11/13 & ACI 318-14
Concrete Retaining Wall Design Based on ACI 318-14
Retaining Wall Design, for Masonry Top & Concrete Bottom, Based on TMS 402-11/13 & ACI 318-14
Concrete Pier (Isolated Deep Foundation) Design Based on ACI 318-14
Drilled Cast-in-place Pile Design Based on ACI 318-14
Pile Cap Design for 4, 3, 2-Piles Pattern Based on ACI 318-14
Determination of Pile Cap Balanced Loads and Reactions
Design of Conventional Slabs on Expansive & Compressible Soil Grade Based on ACI 360
Design of PT Slabs on Expansive & Compressible Soil Based on PTI 3rd Edition
Basement Concrete Wall Design Based on ACI 318-14
Basement Masonry Wall Design Based on TMS 402-11/13
Basement Column Supporting Lateral Resisting Frame Based on ACI 318-14
Grade Beam Design for Moment Resisting Frame Based on ACI 318-14
Grade Beam Design for Brace Frame Based on ACI 318-14
Two Pads with Grade Beam Design Based on ACI 318-14 & AISC 360-10
Circular Footing Design Based on ACI 318-14
Combined Footing Design Based on ACI 318-14
Mat Boundary Spring Generator
Deep Footing Design Based on ACI 318-14
Design of Footing at Piping Based on ACI 318-14
Soil Pressure Determination for Irregular Footing
Pad Footing Design Based on ACI 318-14
Plain Concrete Footing Design Based on ACI 318-14
Restrained Retaining Masonry & Concrete Wall Design Based on TMS 402 & ACI 318
Retaining Wall Design Based on 2013 CBC Chapter A
Tank Footing Design Based on ACI 318-14
Temporary Tank Footing Design Based on ACI 318-14
Under Ground Well Design Based on ACI 350-06 & ACI 318-14
Footing Design for Stud Bearing Wall Based on 2015 IBC / ACI 318-14
Footing Design of Shear Wall Based on ACI 318-14
Fixed Moment Condition Design Based on ACI 318-14
Concrete Floodway Design Based on ACI 350-06 & ACI 318-14
Lateral Earth Pressure of Rigid Wall Based on AASHTO 17th & 2015 IBC
Sheet Pile Wall Design Based on 2015 IBC / 2013 CBC / ACI 318-14
Composite Element Design Based on AISC 360-10 & ACI 318-14

Lateral Analysis Group


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Seismic vs Wind
Wind - ASCE7-10
Seismic - 2015 IBC
Metal Pipe/Riser
Rigid Diaphragm
Flexible Diaphragm
Two Story Moment Frame
X - Braced Frame
Open Structure Wind
Roof Screen/Equipment Wind
Axial Roof Deck
Deformation Compatibility
Discontinuous Shear Wall
Flexible Diaphragm Opening
Hand Rail
Interior Wall Lateral Force
Lateral Frame Formulas
Live Load

Three, Two, and One Story Comparison of Seismic and Wind Based on 2015 IBC / 2013 CBC
Wind Analysis Based on ASCE 7-10
Seismic Analysis Based on ASCE 7-10
MCE Level Seismic Design for Metal Pipe/Riser Based on ASCE 7-10 & AISI S100
Rotation Analysis of Rigid Diaphragm Based on 2015 IBC / 2013 CBC
Flexible Diaphragm Analysis
Two Story Moment Frame Analysis using Finite Element Method
X-Braced Frame Analysis using Finite Element Method
Wind Analysis for Open Structure (Solar Panels) Based on ASCE 7-10 & 05
Wind Load, on Roof Screen / Roof Equipment, Based on ASCE 7-10 & 05
Axial Capacity of 1 1/2" Type "B" Roof Deck Based on ICBO ER-2078P
Column Deformation Compatibility Design using Finite Element Method
Discontinuous Shear Wall Analysis Using Finite Element Method
Flexible Diaphragm with an Opening Analysis
Handrail Design Based on AISC 360-10 & ACI 318-14
Interior Wall Lateral Forces Based on 2015 IBC / 2013 CBC
Lateral Frame Formulas
Live Load Reduction Based on ASCE 7-10, 2015 IBC / 2013 CBC

http://www.engineering-international.com/

8/12/2015

Structural Design Software

19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45

Seismic - Single Family Dwellings


Shade Structure Wind
Shear Wall Forces
Shear Wall - New Opening
Shear Wall Rigidity
Sign
Sign Wind
Snow
Wall Lateral Force - CBC
Wall Lateral Force - IBC
Seismic - 2009 IBC
Wind Girt Deflection
Storage Racks
Wind Alternate Method
Ceiling Seismic Loads
Response Spectrum Generator
Tornado and Hurricane
Stiffness Matrix Generator
PT-Column Drift
Blast Mitigation
Wind - SEAOC-PV2
Wind - ASCE7-05
Self-Centering Frame
General Beam
Trussed Tower Wind
PT Lateral Frame
External PT Beam

Page 3 of 4

Seismic Analysis for Family Dwellings Based on 2015 IBC / 2013 CBC
Wind Analysis for Shade Open Structure Based on ASCE 7-10 & 05
Shear Wall Analysis for Shear Wall with Opening Using Finite Element Method
Relative Rigidity Determination for Shear Wall with New Opening
Rigidity for Shear Wall & Shear Wall with Opening Using Finite Element Method
Sign Design Based on AISC 360-10, ACI 318-14, and IBC 1807.3
Wind Analysis for Freestanding Wall & Sign Based on ASCE 7-10 & 05
Snow Load Analysis Based on ASCE 7-10, 05, & UBC
Lateral Force for One-Story Wall Based on 2013 CBC
Lateral Force for One-Story Wall Based on 2015 IBC
Seismic Analysis Based on 2009 IBC / 2010 CBC
Wind Girt Deflection Analysis of Wood, Metal Stud, and/or Steel Tube
Lateral Loads of Storage Racks, with Hilti & Red Head Anchorage, Based on ASCE 7-10
Wind Analysis for Alternate All-Heights Method, Based on ASCE 7-10
Suspended Ceiling Seismic Loads Based on ASCE 7-10
Earthquake Response Spectrum Generator
Wind Analysis for Tornado and Hurricane Based on 2015 IBC Section 423 & FEMA 361/320
Stiffness Matrix Generator for Irregular Beam/Column
Lateral Drift Mitigation for Cantilever Column using Post-Tensioning
Blast/Explosion Deformation Mitigation for Gravity Column using Post-Tensioning
Wind Design for Low-Profile Solar Photovoltaic Arrays on Flat Roof, Based on SEAOC PV2-2012
Wind Analysis Based on ASCE 7-05, Including Roof Solar Panel Loads
Self-Centering Lateral Frame Design Based on ASCE 7-10, AISC 360-10 & ACI 318-14
General Beam Analysis, including Lateral-Torsional Buckling Length
Wind Analysis for Trussed Tower Based on ASCE 7-10
Post-Tensioned Lateral Frame Analysis using Finite Element Method
Beam Strengthening Analysis Using External Post-Tensioning Systems

Steel Design Group


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68

Thin Composite Beam


Angle Capacity
HSS-WF Capacity
Metal Studs
SMRF - CBC
SCBF-Parallel
SCBF-Perpendicular
Column Above Beam
Beam Gravity
WF Beam with Torsion
HSS (Tube, Pipe) Torsion
Fixed Bolted Joint
Brace Connection
BRBF
BSEP - SMF
Bolted Moment Connection
Channel Capacity
Composite Collector Beam
Composite Floor Beam
Composite Floor Beam with Cantilever
Composite Floor Girder
Drag Connection
Drag Forces for Brace Frame
EBF - CBC
EBF - IBC
Enhanced Composite Beam
Enhanced Steel Beam
Exterior Metal Stud Wall
Floor Deck
Gusset Geometry
Metal Shear Wall
Metal Shear Wall Opening
Metal Z Purlins
OCBF - CBC
OCBF - IBC
Web-Tapered Cantilever Frame
OMRF - CBC
OMRF - IBC
Plate Girder
Rectangular Section
Roof Deck
Base Plate
SMRF - IBC
SPSW
Steel Column
Steel Stair
Triple W Shapes
Portal Frame
Web Tapered Portal
Web Tapered Frame
Web Tapered Girder
Weld Connection
WF Opening
Moment across Girder
Beam Bolted Splice
Filled Composite Column
Cellular Beam
Double Angle Capacity
T-Shape Capacity
Cantilever Column
Metal Truss
Sleeve Joint Connection
Moment to Column Web
Beam Connection
ConXL
Bolt Connection
SCCS and/or OCCS
Non-Prismatic Composite Girder

Thin Composite Beam/Collector Design Based on AISC 360-10 & ACI 318-14
Angle Steel Member Capacity Based on AISC 360-10
Tube, Pipe, or WF Member Capacity Based on AISC 360-10
Metal Member Design Based on AISI S100-07/SI-10 (2015 IBC) & ICBO ER-4943P
Seismic Design for Special Moment Resisting Frames Based on 2013 CBC
Seismic Design for Special Concentrically Braced Frames Based on CBC/IBC & AISC 341-10
Bracing Connection Design, with Perpendicular Gusset, Based on CBC/IBC & AISC 341-10
Connection Design for Column above Beam, Based on AISC Manual & AISC 360-10
Steel Gravity Beam Design Based on AISC Manual 14th Edition (AISC 360-10)
WF Simply Supported Beam Design with Torsional Loading Based on AISC 360-10
HSS (Tube, Pipe) Member Design with Torsional Loading Based on AISC 360-10
Fixed Bolted Joint, with Beam Sitting on Top of Column, Based on AISC 358-10 8ES/4ES & FEMA-350
Typical Bracing Connection Capacity Based on AISC 360-10
Buckling-Restrained Braced Frames Based on AISC 360-10 & AISC 341-10
Bolted Seismic Moment Connection Based on AISC 341-10, 358-10, 360-10 & FEMA-350
Bolted Non-Seismic Moment Connection Based on AISC 341-10, 358-10, 360-10 & FEMA-350
Channel Steel Member Capacity Based on AISC 360-10
Composite Collector Beam with Seismic Loads Based on 2013 CBC / 2015 IBC
Composite Beam Design Based on AISC Manual 9th
Composite Beam Design Based on AISC 360-10 / 2015 IBC / 2013 CBC
Composite Girder Design Based on AISC 360-10 / 2015 IBC / 2013 CBC
Drag Connection Based on AISC 360-10 & AISC 341-10
Drag / Collector Forces for Brace Frame
Seismic Design for Eccentrically Braced Frames Based on 2013 CBC & AISC 341-10
Seismic Design for Eccentrically Braced Frames Based on 2015 IBC & AISC 341-10
Enhanced Composite Beam Design Based on AISC 360-10 / 2015 IBC / 2013 CBC
Enhanced Steel Beam Design Based on AISC 14th (AISC 360-10)
Exterior Metal Stud Wall Design Based on AISI S100-07/SI-10 & ER-4943P
Depressed Floor Deck Capacity (Non-Composite)
Gusset Plate Dimensions Generator
Metal Shear Wall Design Based on AISI S100-07/SI-10, ER-5762 & ER-4943P
Metal Shear Wall with an Opening Based on AISI S100-07/SI-10, ER-5762 & ER-4943P
Metal Z-Purlins Design Based on AISI S100-07/SI-10
Ordinary Concentrically Braced Frames Based on 2013 CBC & AISC 341-10
Ordinary Concentrically Braced Frames Based on 2015 IBC & AISC 341-10
Web-Tapered Cantilever Frame Design Based on AISC-ASD 9th, Appendix F
Intermediate/Ordinary Moment Resisting Frames Based on 2013 CBC
Intermediate/Ordinary Moment Resisting Frames Based on 2015 IBC
Plate Girder Design Based on AISC Manual 14th Edition (AISC 360-10)
Rectangular Section Member Design Based on AISC 360-10
Design of 1 1/2" Type "B" Roof Deck Based on ICBO ER-2078P
Base Plate Design Based on AISC Manual 14th Edition (AISC 360-10)
Special Moment Resisting Frames Based on 2015 IBC, AISC 341-10 & 358-10
Seismic Design for Special Plate Shear Wall Based on AISC 341-10 & AISC 360-10
Steel Column Design Based on AISC Manual 14th Edition (AISC 360-10)
Steel Stair Design Based on AISC 360-10
Simply Supported Member of Triple W-Shapes Design Based on AISC 360-10
Portal Frame Analysis using Finite Element Method
Web Tapered Portal Design Based on AISC-ASD 9th Appendix F and/or AISC Design Guide 25
Web Tapered Frame Design Based on AISC-ASD 9th Appendix F and/or AISC Design Guide 25
Web Tapered Girder Design Based on AISC-ASD 9th Appendix F and/or AISC Design Guide 25
Weld Connection Design Based on AISC 360-10
Check Capacity of WF Beam at Opening Based on AISC 360-10
Design for Fully Restrained Moment Connection across Girder Based on AISC 360-10
Beam Bolted Splice Design Based on AISC Manual 14th Edition (AISC 360-10)
Filled Composite Column Design Based on AISC 360-10 & ACI 318-14
Cellular Beam Design Based on AISC 360-10
Double Angle Capacity Based on AISC 360-10
T-Shape Member Capacity Based on AISC 360-10
Cantilever Column & Footing Design Based on AISC 360-10, ACI 318-14, and IBC 1807.3
Light Gage Truss Design Based on AISI S100-07/SI-10 & ER-4943P
Sleeve Joint Connection Design, for Steel Cell Tower / Sign, Based on AISC 360-10
Moment Connection Design for Beam to Weak Axis Column Based on AISC 360-10
Beam Connection Design Based on AISC 360-10
Seismic Bi-axial Moment Frame Design Based on AISC 358-10 & ACI 318-14
Bolt Connection Design Based on AISC Manual 14th Edition (AISC 360-10)
Cantilever Column System (SCCS/OCCS) Design Based on AISC 341-10/360-10 & ACI 318-14
Non-Prismatic Composite Girder Design Based on AISC 360-10 / 2013 CBC / 2015 IBC

http://www.engineering-international.com/

8/12/2015

Structural Design Software

Page 4 of 4

Technical Support
Purchaser will receive, by USB flash drive, the purchased XLSB/XLS version software within 4 days (network version can be downloaded on the purchased day). For package purchaser, please email
us your left top logo with your order. Any our software bugs can be fixed promptly, and the updated software will be emailed back to reporter.
License:

Single Package License for single user with one computer (one Laptop or Tablet/PAD ok). ($1760)
Two Package License for two users with five computers (two Laptops or Tablets/PADs ok). ($2686)
Three Package License (Network Version) for one company without Laptop/Tablet/PAD number limits (all software can be loaded/run by double click each software on both 64 bit and 32 bit Excel

http://www.engineering-international.com/

8/12/2015

End User License Agreement


IMPORTANT-READ CAREFULLY: This End-User License Agreement ("EULA") is a legal agreement between you (either an individual or a
single entity) and Daniel T. Li, Engineering International Inc. ("DTL") for the DTL software ("spreadsheets") that accompanies this EULA. YOU
AGREE TO BE BOUND BY THE TERMS OF THIS EULA BY DOWNLOADING AND/OR USING THE SOFTWARE. IF YOU DO NOT
AGREE, DO NOT LOAD THE PACKAGE SOFTWARE ON YOUR COMPUTER.
1. DISCLAIMER
The purchased professional version are XLSB/XLS software by enhanced Microsoft Windows Excel 2010/2013 (32 bit default installation). We do
not provide unprotected spreadsheet (original software code) or individual software because all software database linked together for full functions.
DO NOT UNPROTECT the spreadsheets. Without the right bottom of Quick Access Toolbar, the calculations, at random times, will be inadequate
and entire Package database will be changed. The IP address and time which linked our web site will be recorded.
DTL intends that the analysis is accurate and reliable, but it is entirely the responsibility of the user to verify the accuracy and applicability. DTL
entire liability shall be limited to the purchase price.
2. SOFTWARE LICENSE
The software is licensed, not sold. All right, title and interest is and remains vested in DTL. You may not rent, lease, or lend the software.
(a) Single Package License, and Select Individuals License, for single user with one computer (one Laptop or Tablet/PAD ok).
(b) Two Package License for two users with five computers (two Laptops or Tablets/PADs ok).
(c) Three Package License (Network Version) for one company without Laptop/Tablet/PAD number limits (all software can be loaded/run by
double click each software on both 64 bit and 32 bit Excel 2013/2010).
3. UPGRADING SERVICE
DTL provides upgrading service, for Package purchaser only, with service fee as mentioned on DTL web site. The upgrading service includes new
software that released after your purchased date. When your purchased software has not been upgraded for more than one year, you will be given
the opportunity to continue getting upgrading service on an annual basis fee.
4. TERMINATION
DTL may terminate your right to use the software if you fail to comply with the terms and conditions of this agreement. All disputes shall be
resolved in accordance with the laws of the State of California, USA and all parties to this Agreement expressly agree to exclusive jurisdiction
within the State of California, USA. No choice of law rules of any jurisdiction apply.

Accept and Continue

Not Accept
Copyright 2002 - 2013 Daniel T. Li, Engineering International Inc., All Rights Reserved.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Pad Footing Design Based on ACI 318-08


INPUT DATA

DESIGN SUMMARY

COLUMN WIDTH

c1

in

FOOTING WIDTH

3.00

COLUMN DEPTH

c2

in

FOOTING LENGTH

4.00

ft

BASE PLATE WIDTH

b1

16

in

FOOTING THICKNESS

12

in

BASE PLATE DEPTH

b2

16

in

LONGITUDINAL REINF.

15

in o.c.

FOOTING CONCRETE STRENGTH

fc'

2.5

ksi

TRANSVERSE REINF.

14

in o.c.

REBAR YIELD STRESS

fy

60

ksi

AXIAL DEAD LOAD

PDL

25

AXIAL LIVE LOAD

PLL

4.5

LATERAL LOAD (0=WIND, 1=SEISMIC)


PLAT
SEISMIC AXIAL LOAD

=
=

1
-6

Seismic,SD
k, SD

SURCHARGE

qs

ksf

SOIL WEIGHT

ws

0.11

kcf

FOOTING EMBEDMENT DEPTH

Df

ft

12

in

ALLOW SOIL PRESSURE

Qa

2.5

ksf

FOOTING WIDTH
FOOTING LENGTH
BOTTOM REINFORCING

B
L

=
=
#

3
4
5

=
=
=

37
29
17

FOOTING THICKNESS

ft

ft
ft

THE PAD DESIGN IS ADEQUATE.

ANALYSIS
DESIGN LOADS (IBC SEC.1605.3.2 & ACI 318-08 SEC.9.2.1)
CASE 1:
DL + LL
P =
30
kips
CASE 2:
DL + LL + E / 1.4
P =
25
kips
CASE 3:
0.9 DL + E / 1.4
P =
18
kips

1.2 DL + 1.6 LL
1.2 DL + 1.0 LL + 1.0 E
0.9 DL + 1.0 E

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)


CASE 1
P
+ q S + (0.15 w S )T =
q MAX =
2.50 ksf,

CASE 2
2.14 ksf,

BL

q MAX

<

kQa,

Pu
Pu
Pu

CASE 3
1.56 ksf
[Satisfactory]

where k = 1 for gravity loads, 4/3 for lateral loads.

DESIGN FOR FLEXURE (ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)
0.85 f c 1 1
'

Mu
0.383bd 2 f 'c

MAX =

fy

fy

u
u +t

MIN = MIN 0.0018

LONGITUDINAL
8.69
36
3.10
11.35

d
b
q u,max
Mu

min
As
ReqD
Max. Spacing
USE
max
Check prod < max

0.85 1 f c'

TRANSVERSE
8.38
48
3.10
7.00

0.001
0.001
0.39
#
5
18
in o.c.
3
#
5
0.013
[Satisfactory]

T
4
,
d
3

0.000
0.001
0.25

#
5
18
in o.c.
4
#
5
0.013
[Satisfactory]

__
@ 15 in o.c.

Page 12 of 533
524

@ 14 in o.c.

kips
kips
kips

(cont'd)

CHECK FLEXURE SHEAR (ACI 318-08 SEC.9.3.2.3, 15.5.2, 11.1.3.1, & 11.2)

V n = 2 bd f 'c
Vu

Vn
Check Vu < Vn

LONGITUDINAL
7.80

TRANSVERSE
4.52

0.75
23.5
[Satisfactory]

0.75
30.2
[Satisfactory]

CHECK PUNCHING SHEAR (ACI 318-08 SEC.15.5.2, 11.11.1.2, 11.11.6, & 13.5.3.2)

V n = ( 2 + y )
where

f c' A p

97.42

kips

=
=

0.75 (ACI 318-08, Section 9.3.2.3 )


ratio of long side to short side of concentrated load

b0

c1 + c2 + b1 + b2 + 4d

Ap

b0 d

MIN(2 , 4 / c , 40 d / b0)

V u = P u, max 1

1 b1 + c1
+d
BL
2

649.4

b2 + c2 + d
2

76.1

1.00

in

in2

2.0

29.40 kips

<

__
Page 13 of 533
524

[Satisfactory]

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Pad Footing Design Based on ACI 318-95 / CBC 2001


INPUT DATA

DESIGN SUMMARY

COLUMN WIDTH

c1

in

FOOTING WIDTH

3.00

COLUMN DEPTH

c2

in

FOOTING LENGTH

4.00

ft

BASE PLATE WIDTH

b1

16

in

FOOTING THICKNESS

12

in

BASE PLATE DEPTH

b2

16

in

LONGITUDINAL REINF.

15

in o.c.

FOOTING CONCRETE STRENGTH

fc'

2.5

ksi

TRANSVERSE REINF.

14

in o.c.

REBAR YIELD STRESS

fy

60

ksi

AXIAL DEAD LOAD

PDL

25

AXIAL LIVE LOAD

PLL

4.5

LATERAL LOAD (0=WIND, 1=SEISMIC)


PLAT
SEISMIC AXIAL LOAD

=
=

1
-6

Seismic,SD
k, SD

SURCHARGE

qs

ksf

SOIL WEIGHT

ws

0.11

kcf

FOOTING EMBEDMENT DEPTH

Df

ft

12

in

ALLOW SOIL PRESSURE

Qa

2.5

ksf

FOOTING WIDTH
FOOTING LENGTH
BOTTOM REINFORCING

B
L

=
=
#

3
4
5

=
=
=

43
29
17

FOOTING THICKNESS

ft

ft
ft

THE PAD DESIGN IS ADEQUATE.

ANALYSIS
DESIGN LOADS (CBC SEC.1612.3.2, 1612.2.1 & ACI 318-95 SEC.9.2.1)
CASE 1:
DL + LL
P =
30
kips
CASE 2:
DL + LL + E / 1.4
P =
25
kips
CASE 3:
0.9 DL + E / 1.4
P =
18
kips

1.4 DL + 1.7 LL
1.2 DL + 1.0 LL + 1.0 E
0.9 DL + 1.0 E

CHECK SOIL BEARING CAPACITY (ACI 318-95 SEC.15.2.2)


CASE 1
P
+ q S + (0.15 w S )T =
q MAX =
2.50 ksf,

CASE 2
2.14 ksf,

BL

q MAX

<

kQa,

Pu
Pu
Pu

CASE 3
1.56 ksf
[Satisfactory]

where k = 1 for gravity loads, 4/3 for lateral loads.


DESIGN FOR FLEXURE (ACI 318-95 SEC.15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, & 12.5)
0.85 f c 1 1
'

Mu
0.383bd 2 f 'c

MAX = 0.75

fy

MIN = MIN 0.0018

LONGITUDINAL
8.69
36
3.55
13.02

d
b
q u,max
Mu

min
As
ReqD
Max. Spacing
USE
max
Check prod < max

'
0.85 1 f c
87
87 + f y
f y

TRANSVERSE
8.38
48
3.55
8.02

0.001
0.001
0.45
#
5
18
in o.c.
3
#
5
0.013
[Satisfactory]

T
4
,
d
3

0.001
0.001
0.29

#
5
18
in o.c.
4
#
5
0.013
[Satisfactory]

__
@ 15 in o.c.

Page 14 of 533
524

@ 14 in o.c.

kips
kips
kips

(cont'd)
CHECK FLEXURE SHEAR (ACI 318-95 SEC.9.3.2.3, 15.5.2, 11.1.3.1, & 11.3)

V n = 2 bd f 'c
Vu

Vn
Check Vu < Vn

LONGITUDINAL
8.94

TRANSVERSE
5.18

0.85
26.6
[Satisfactory]

0.85
34.2
[Satisfactory]

CHECK PUNCHING SHEAR (ACI 318-95 SEC.15.5.2, 11.12.1.2, 11.12.6, & 13.5.3.2)

V n = ( 2 + y )
where

f c' A p

110.41 kips

=
=

0.85 (ACI 318-95, Section 9.3.2.3 )


ratio of long side to short side of concentrated load

b0

c1 + c2 + b1 + b2 + 4d

Ap

b0 d

MIN(2 , 4 / c , 40 d / b0)

V u = P u, max 1

1 b1 + c1
+d
BL
2

649.4

b2 + c2 + d
2

76.1

1.00

in

in2

2.0

33.71 kips

<

__
Page 15 of 533
524

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Eccentric Footing Design Based on ACI 318-08


INPUT DATA

DESIGN SUMMARY

COLUMN WIDTH

c1

in

FOOTING WIDTH

16.00

COLUMN DEPTH

c2

in

FOOTING LENGTH

7.00

ft

BASE PLATE WIDTH

b1

16

in

FOOTING THICKNESS

12

in

BASE PLATE DEPTH

b2

16

in

LONGITUDINAL REINF., TOP

FOOTING CONCRETE STRENGTH

fc'

2.5

ksi

LONGITUDINAL REINF., BOT.

23 # 5 @ 8 in o.c.

REBAR YIELD STRESS

fy

60

ksi

TRANSVERSE REINF., BOT.

6 # 5 @ 15 in o.c.

AXIAL DEAD LOAD

PDL

50

AXIAL LIVE LOAD

PLL

4.5

LATERAL LOAD (0=WIND, 1=SEISMIC)


PLAT
WIND AXIAL LOAD

=
=

0
1

Wind,ASD
k, ASD

WIND MOMENT LOAD

MLAT

15

ft-k, ASD

WIND SHEAR LOAD

VLAT

2.5

k, ASD

SURCHARGE

qs

0.1

ksf

SOIL WEIGHT

ws

0.11

kcf

FOOTING EMBEDMENT DEPTH

Df

ft

12

in

ALLOW SOIL PRESSURE

Qa

ksf

FOOTING WIDTH

B1

10

ft

B2

ft

L1

ft

L2

ft

FOOTING THICKNESS

FOOTING LENGTH
REINFORCING SIZE

ft

1#5

THE FOOTING DESIGN IS ADEQUATE.

ANALYSIS
DESIGN LOADS AT TOP OF FOOTING (IBC SEC.1605.3.2 & ACI 318-08 SEC.9.2.1)
CASE 1:
DL + LL
P
=
55
kips
M
=
136 ft-kips
e
=
2.5 ft, fr cl ftg
CASE 2:
DL + LL + 1.3 W
P
=
56
kips
M
=
162 ft-kips
V
=
3
kips
e
=
2.9 ft, fr cl ftg
CASE 3:
DL + LL + 0.65 W
P
=
55
kips
M
=
147 ft-kips
V
=
1
kips
e
=
2.7 ft, fr cl ftg

1.2 DL + 1.6 LL

1.2 DL + LL + 1.6 W

0.9 DL+ 1.6 W

CHECK OVERTURNING FACTOR (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)

>
F = 1.6 / 0.9 =
9.2
MLAT + VLAT T - PLATL2 =

17

(0.15 kcf) T B L =

16.80

k, footing weight

Psoil =

ws (Df - T) B L =

12.32

k, soil weight

MR =

PDLL2 + 0.5 (Pftg + Psoil) L =

MR / MO =
Where MO =
Pftg =

1.78

[Satisfactory]
k-ft

152

k-ft

FOR REVERSED LATERAL LOADS,


MR / MO =
Where MO =
MR =

28.7

>

F = 1.6 / 0.9

MLAT + VLAT Df - PLATL1 =

14

1.5 (VLat, ASD) =

3.75
=

0.4

kips

k-ft

__

PDLL1 + 0.5 (Pftg + Psoil) L =

CHECK SLIDING (IBC 09 1807.2.3)

Where `

[Satisfactory]

402

<

W =

k-ft

26.72

Page 16 of 533
524

kips

[Satisfactory]

Pu
Mu
eu
Pu
Mu
Vu
eu
Pu
Mu
Vu
eu

=
=
=
=
=
=
=
=
=
=
=

67
168
2.5
66
189
4
2.9
47
141
4
3.0

kips
ft-kips
ft, fr cl ftg
kips
ft-kips
kips
ft, fr cl ftg
kips
ft-kips
kips
ft, fr cl ftg

(cont'd)

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)


Service Loads
P
e
qs B L

CASE 1
54.5
2.5

CASE 2
55.8
3.0

CASE 3
55.2
2.7

k
ft (from center of footing)

11.2

11.2

11.2

k, (surcharge load)

(0.15-ws)T B L
P
eL

4.5
70.2
1.9

> L/6

4.5
71.5
2.3

> L/6

4.5
70.8
2.1

> L/6

k, (footing increased)
k
ft

eB

1.6

< B/6

1.6

< B/6

1.6

< B/6

qL

30.0

40.2

33.4

k / ft

qmax

3.0

4.0

3.3

ksf

qallow

3.0

4.0

4.0

ksf

Where

6
1+ eL
L
L
, for e L
6
L
2 ( P )
L
, for e L >
3(0.5L e L)
6

( P )
qL =

q MAX

6e
q L 1+ B
B
,
=
B
2q L
,
3(0.5B e B )

ft

B
6
B
for e B >
6

for e B

[Satisfactory]

DESIGN FLEXURE & CHECK FLEXURE SHEAR


(ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, 12.5, 15.5.2, 11.1.3.1, & 11.2)

( Pu )

6eu
L

L
, for eu
6
L
, for eu >
3B(0.5L eu)
6

qu,MAX =

BL
2 ( Pu )

0.85 f c 1 1
'

1+

MAX =

Mu
0.383b d 2 f c'

0.85 1 f 'c
fy

MIN = MIN 0.0018

fy

FACTORED SOIL PRESSURE


Factored Loads
CASE 1

u
u +t

T
4

,
d
3

CASE 2

CASE 3

Pu

67.2

66.1

46.6

eu

2.5

2.9

3.1

ft

qs B L

17.9

11.2

0.0

k, (factored surcharge load)


k, (factored footing & backfill loads)

[0.15T + ws(Df - T)]BL


Pu
eu

34.9

34.9

26.2

120.1

112.2

72.8

1.4

qu, max

> L/6

1.7

2.381

> L/6

2.0

2.630

k
> L/6

ft

2.002

FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 1


0.25 L1 0.50 L1 0.75 L1
ColL
0
Section

ColR

ksf

0.25 L2 0.50 L2 0.75 L2

Xu (ft, dist. from left of footing)

1.50

3.00

4.50

5.56

6.44

6.25

6.50

6.75

7.00

Mu,col (ft-k)

-29.4

-16.8

-33.6

-50.4

-67.2
67.2

Vu,col (k)

0.0

0.0

0.0

0.0

67.2

67.2

67.2

67.2

Pu,surch (klf)

2.56

2.56

2.56

2.56

2.56

2.56

2.56

2.56

2.56

2.56

Mu,surch (ft-k)

-2.9

-11.5

-25.9

-39.6

-53.0

-50.0

-54.1

-58.3

-62.7
17.9

Vu,surch (k)

3.8

7.7

11.5

14.2

16.5

16.0

16.6

17.3

Pu,ftg & fill (klf)

4.99

4.99

4.99

4.99

4.99

4.99

4.99

4.99

4.99

4.99

Mu,ftg & fill (ft-k)

-5.6

-22.5

-50.5

-77.2

-103.4

-97.5

-105.5

-113.7

-122.3
34.9

Vu,ftg & fill (k)

7.5

15.0

22.5

27.8

32.1

31.2

32.4

33.7

qu,soil (ksf)

0.00

0.51

1.02

1.53

1.89

2.19

2.13

2.21

2.30

2.38

Mu,soil (ft-k)

189.5

288.9

316.3

302.3

275.2

282.0

272.8

262.9

252.2

Vu,soil (k)

-48.2

-84.1

-107.8

-117.2

-120.3

-120.0

-120.3

-120.4

-120.1

Mu (ft-k)

181.1

254.9

239.8

185.5

89.3

117.7

79.7

40.5

Vu (kips)

-36.9

-61.5

-73.8

-75.2

-4.5

-5.6

-4.0

-2.2

__
Page 17 of 533
524

(cont'd)
FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 2
0.25 L1 0.50 L1 0.75 L1
ColL
0
Section

ColR

0.25 L2 0.50 L2 0.75 L2

Xu (ft, dist. from left of footing)

1.50

3.00

4.50

5.56

6.44

6.25

6.50

6.75

7.00

Mu,col (ft-k)

-0.9

11.5

-5.1

-21.6

-38.1
66.1

Vu,col (k)

0.0

0.0

0.0

0.0

66.1

66.1

66.1

66.1

Pu,surch (klf)

1.60

1.60

1.60

1.60

1.60

1.60

1.60

1.60

1.60

1.60

Mu,surch (ft-k)

-1.8

-7.2

-16.2

-24.8

-33.2

-31.3

-33.8

-36.5

-39.2

Vu,surch (k)

2.4

4.8

7.2

8.9

10.3

10.0

10.4

10.8

11.2

Pu,ftg & fill (klf)

4.99

4.99

4.99

4.99

4.99

4.99

4.99

4.99

4.99

4.99

Mu,ftg & fill (ft-k)

-5.6

-22.5

-50.5

-77.2

-103.4

-97.5

-105.5

-113.7

-122.3

Vu,ftg & fill (k)

7.5

15.0

22.5

27.8

32.1

31.2

32.4

33.7

34.9

qu,soil (ksf)

0.00

0.00

1.13

1.69

2.09

2.42

2.35

2.44

2.54

2.63

Mu,soil (ft-k)

0.0

261.9

276.8

255.6

224.3

231.8

221.7

210.9

199.6

Vu,soil (k)

0.0

-84.2

-106.0

-113.2

-114.1

-114.3

-114.0

-113.3

-112.2

Mu (ft-k)

-7.4

232.2

210.0

153.6

86.8

114.6

77.4

39.2

Vu (kips)

9.9

-64.4

-76.3

-76.6

-5.6

-7.0

-5.0

-2.7

FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 3


0.25 L1 0.50 L1 0.75 L1
ColL
0
Section

ColR

Xu (ft, dist. from left of footing)

1.50

3.00

4.50

Mu,col (ft-k)

Vu,col (k)

0.0

0.0

0.0

5.56

0.25 L2 0.50 L2 0.75 L2

6.44

6.25

7.6

16.4

0.0

46.6

46.6

6.50

6.75

7.00

4.7

-7.0

-18.6

46.6

46.6

46.6

Pu,surch (klf)

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

Mu,surch (ft-k)

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

Vu,surch (k)

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

Pu,ftg & fill (klf)

3.74

3.74

3.74

3.74

3.74

3.74

3.74

3.74

3.74

3.74

Mu,ftg & fill (ft-k)

-4.2

-16.8

-37.9

-57.9

-77.6

-73.1

-79.1

-85.3

-91.7

Vu,ftg & fill (k)

5.6

11.2

16.8

20.8

24.1

23.4

24.3

25.3

26.2

qu,soil (ksf)

0.00

0.00

0.86

1.29

1.59

1.84

1.79

1.86

1.93

2.00

Mu,soil (ft-k)

0.0

167.1

170.4

151.9

128.1

133.7

126.2

118.4

110.3

Vu,soil (k)

0.0

-58.7

-72.5

-76.2

-75.2

-75.7

-75.0

-74.1

-72.8

Mu (ft-k)

-4.2

150.3

132.5

94.0

58.2

76.9

51.8

26.2

Vu (kips)

5.6

-47.4

-55.7

-55.3

-4.5

-5.7

-4.1

-2.2

DESIGN FLEXURE
Location
Top Longitudinal
Bottom Longitudinal
Bottom Transverse

Mu,max
-7.4 ft-k
254.9 ft-k
1
ft-k / ft

d (in)
9.69
8.69
8.38

min
reqD
max
smax
0.0001 0.0001 0.0129 no limit
0.0025 0.0041 0.0129
18
0.0004 0.0003 0.0129
18

use
1#5
23 # 5 @ 8 in o.c.
6 # 5 @ 15 in o.c.

provD
0.0002
0.0043
0.0026
[Satisfactory]

CHECK FLEXURE SHEAR


Direction

Vc = 2 b d (fc')0.5

Vu,max

Longitudinal
Transverse

76.6
4.3

k
k / ft

125
8

check Vu < Vc

k
k / ft

[Satisfactory]
[Satisfactory]

CHECK PUNCHING SHEAR (ACI 318-08 SEC.15.5.2, 11.11.1.2, 11.11.6, & 13.5.3.2)

v u ( psi ) =
3
d b1

J =

R=

P u R 0.5 v M u b1
+
J
AP
1+

d
b1

2
+3

where

v = 1

b2
b1

v c( psi ) = ( 2 + y )

1
1+

2
3

y = MIN 2,

b1
b2

b0 =

A f = BL

P u b1b2
Af
Case
1
2
3

A P = 2 ( b1 + b 2 ) d

Pu
67.2
66.1
46.6

Mu
168.0
189.3
140.5

b1
18.9
18.9
18.9

0.75

b0
0.5
0.5
0.5

v
0.4
0.4
0.4

c
1.0
1.0
1.0

y
2.0
2.0
2.0

(ACI 318-08, Section 9.3.2.3 )

Page 18 of 533
524

, 40

d
b0

AP
, b1 = ( 0.5c1 + 0.5b1 + d ) , b 2 = ( 0.5c 2 + 0.5b 2 + d )
d

__

b2
18.9
18.9
18.9

'
fc

Af
112.0
112.0
112.0

Ap
4.4
4.4
4.4

R
1.5
1.5
1.0

J
1.9
1.9
1.9

vu (psi)
105.3
103.7
73.2

vc
150.0
150.0
150.0
[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Footing Design for Stud Bearing Wall Based on IBC 09 / ACI 318-08
INPUT DATA & DESIGN SUMMARY
FOOTING SIZE

A
B
C
D
E

=
=
=
=
=

18
6
16
8
3

in
in
in
in
in

FOOTING CONCRETE STRENGTH

fc'

2.5

ksi

AXIAL DEAD LOAD (per linear foot)

PDL

1.5

k / ft

AXIAL LIVE LOAD (per linear foot)

PLL

0.6

k / ft

LATERAL LOAD (0=WIND, 1=SEISMIC)


PLAT
LATERAL LOAD (per linear foot)

=
=

1
0.8

Seismic,SD
k / ft, SD

(holdown force converted to load per linear foot)


SURCHARGE

qs

0.1

ksf

SOIL WEIGHT

ws

0.11

kcf

ALLOWABLE SOIL PRESSURE

Qa

ksf

THE FOOTING DESIGN IS ADEQUATE.

ANALYSIS
DESIGN LOADS (IBC SEC.1605.3.2 & ACI 318-08 SEC.9.2.1)
CASE 1:
CASE 2:
CASE 3:

DL + LL
DL + LL + E / 1.4
0.9 DL + E / 1.4

P
P
P

=
=
=

2.10
2.67
1.92

k / ft
k / ft
k / ft

1.2 DL + 1.6 LL
1.2 DL + 1.0 LL + 1.0 E
0.9 DL + 1.0 E

Pu
Pu
Pu

=
=
=

2.76
3.20
2.15

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)


Service Loads
P
e
qs C
(0.15-ws) Area

CASE 1
2.10
1.0
0.13
0.07

CASE 2
2.67
1.0
0.13
0.07

CASE 3
1.92
1.0
0.13
0.07

2.3
1.0
2.36
3.00

2.9
1.0
2.95
3.00

2.1
1.0
2.17
3.00

P
e
qmax
Qa
Where

( P )

1+

[Satisfactory]

6e
C

C
, for e
6
C
2 ( P )
C
, for e >
3(0.5C e)
6

q max =

DESIGN FOR FLEXURE (ACI 318-08 SEC.22.5.1)

M n = MIN 5
where

'
'
f c S , 0.85 f cS

=
=
=
=

0.90

ft-kips / ft

1.0 (ACI 318-08, Section 8.6.1 )


0.6 (ACI 318-08, Section 9.3.5 )
elastic section modulus of section
3
72 in / ft

__
Page 19 of 533
524

k / ft
in (from center of footing)
k / ft, (surcharge load)
k / ft, (footing increased)
k / ft
in
ksf
ksf

k / ft
k / ft
k / ft

(cont'd)
FACTORED SOIL PRESSURE
Factored Loads
CASE 1
Pu
2.8
1.0
eu
qs C
0.21
[0.15AC - (0.15-Ws) (C-D) (A-B) ]

Pu
eu
E
qu, max
qu, VL
qu, ML
qu, MR
qu, VR
qu, min
M u, L
M u, R
V u, L
V u, R
M u, max =

0.15

ft-k / ft

CASE 2
3.2
1.0
0.21

CASE 3
2.2
1.0
0.21

0.33
3.30
0.9

0.33
3.74
0.9

0.25
2.61
0.9

3.0
3.27
3.27
2.98
2.18
1.68
1.68
0.09
0.13
0.00
0.00

3.0
3.73
3.73
3.38
2.46
1.88
1.88
0.10
0.15
0.00
0.00

3.0
2.58
2.58
2.35
1.72
1.33
1.33
0.07
0.10
0.00
0.00

<

[Satisfactory]

CHECK FLEXURE SHEAR (ACI 318-08 SEC.22.5.4)

V n =

where
V u, max =

'

f cB

2.88

k / ft

0.6

(ACI 318-08, Section 9.3.5 )

0.00

k / ft

<

[Satisfactory]

__
Page 20 of 533
524

k / ft
in (from center of footing)
k / ft, (factored surcharge load)
k / ft, (factored footing & backfill loads)

k / ft
in
in
ksf
ksf
ksf
ksf
ksf
ksf
ft-k / ft
ft-k / ft
k / ft
k / ft

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Footing Design of Shear Wall Based on ACI 318-08


INPUT DATA
WALL LENGTH

Lw =

16.5

ft

WALL HEIGHT

h =

11

ft

WALL THICKNESS

t =

in

FOOTING LENGTH

L =

25

ft

L1 =

4.25

ft

B =

ft

T=

24

in

D =

ft

FOOTING WIDTH
FOOTING THICKNESS
FOOTING EMBEDMENT DEPTH

qa =

ksf

DEAD LOAD AT TOP WALL

ALLOWABLE SOIL PRESSURE

Pr,DL =

110

kips

LIVE LOAD AT TOP WALL

Pr,LL =

110

kips

a =

8.25

ft

Pw =

15.6

kips

F =

62.5

kips

M =

812.4

ft-kips

CONCRETE STRENGTH

fc' =

ksi

REBAR YIELD STRESS

fy =

60

ksi

TOP LOAD LOCATION


WALL SELF WEIGHT
LATERAL LOAD TYPE (0=wind,1=seismic)

SEISMIC LOADS AT TOP (E/1.4 , ASD)

seismic
THE FOOTING DESIGN IS ADEQUATE.

TOP BARS, LONGITUDINAL

BOTTOM BARS, LONGITUDINAL

12

BOTTOM BARS, TRANSVERSE

in o.c.

ANALYSIS
CHECK OVERTURNING FACTOR (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
F = MR / MO =
Where

1.25

Pf =

36.25

>

1.4 x 0.75 / 0.9

for seismic

[Satisfactory]

kips (footing self weight)

MO = F (h + D) + M =

1625

ft-kips (overturning moment)

MR = (Pr,DL) (L1 + a) + Pf (0.5 L) + Pw (L1 + 0.5Lw) =

2023

ft-kips (resisting moment without live load)

CHECK SOIL CAPACITY (ALLOWABLE STRESS DESIGN)


Ps =

25

kips (soil weight in footing size)

P = (Pr,DL + Pr,LL) + Pw + (Pf - Ps) =

246.85

kips (total vertical net load)

MR = (Pr,DL + Pr, LL) (L1 + a) + Pf (0.5 L) + Pw (L1 + 0.5Lw) =


e = 0.5 L - (MR - MO) / P =

5.32

3398

ft-kips (resisting moment with live load)

ft (eccentricity from middle of footing)

6e
L
L
, for e
6
BL
L
2P
, for e >
3B(0.5L e )
6
P 1+

q MAX =

4.58

ksf

<

4 / 3 qa
[Satisfactory]

Where

e=

5.32

ft, > (L / 6)

CHECK FOOTING CAPACITY (STRENGTH DESIGN)


Mu,R =

1.2 [Pr,DL (L1 + a) + Pf (0.5 L) + Pw (L1 + 0.5Lw)] + 0.5 Pr, LL(L1 + a) =

Mu,o =

1.4 [F(h + D) + M] =

Pu =

1.2 (Pr,DL + Pf + Pw ) + 0.5 Pr, LL =

eu = 0.5L - (Mu,R - Mu,O) / Pu =

q u ,MAX =

2275

9.13

3115

ft-kips
249

kips

ft

__

6e u
Pu 1 +
L
L
, for e u
6
BL
2Pu
L
, for e u >
3B(0.5L e u)
6

9.85

Page 21 of 533
524

ksf

ft-kips

(cont'd)
BENDING MOMENT & SHEAR AT EACH FOOTING SECTION
Section

1/10 L

2/10 L

3/10 L

4/10 L

5/10 L

6/10 L

7/10 L

8/10 L

9/10 L

Xu (ft)

2.50

5.00

7.50

10.00

12.50

15.00

17.50

20.00

22.50

25.00

Pu,w (klf)

0.0

0.0

58.0

42.9

27.7

12.5

-2.7

-17.9

-33.1

0.0

0.0

Mu,w (ft-k)

-17

-296

-842

-1562

-2359

-3139

-3808

-4332

-4846
-206

Vu,w (kips)

-45

-171

-260

-310

-322

-296

-232

-206

Pu,f (ksf)

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Mu,f (ft-k)

-5

-22

-49

-87

-136

-196

-266

-348

-440

-544

Vu,f (kips)

-4

-9

-13

-17

-22

-26

-30

-35

-39

-44

qu (ksf)

-9.9

-7.4

-5.0

-2.5

-0.1

0.0

0.0

0.0

0.0

0.0

0.0

Mu,q (ft-k)

141

514

1043

1652

2275

2898

3521

4144

4767

5390

Vu,q (kips)

108

185

233

249

249

249

249

249

249

249

Mu (ft-k)

136

475

699

722

577

343

115

-12

-5

Vu (kips)

104

132

48

-28

-82

-99

-77

-18

1000
500
0

-500

200
100
0
-100
-200

d (in)

reqD

provD

Vu,max

Top Longitudinal

-12

ft-k

20.50

0.0001

0.0026

132

kips

132

Bottom Longitudinal

722

ft-k

20.44

0.0068

0.0073

132

kips

132

kips

Bottom Transverse

ft-k / ft

19.50

0.0018

0.0019

kips / ft

25

kips / ft

Mu,max

Location

0.85 f 'c 1 1
Where

MAX =

f
0.85 1 f c'
fy

Mu
'
0.383b d 2 f c

min

Vc = 2 b d (fc')0.5

0.0018

u +t

0.0206

__
Page 22 of 533
524

[Satisfactory]

kips

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Grade Beam Design for Brace Frame Based on ACI 318-08


INPUT DATA
AXIAL DEAD LOAD

COL#1
15
kips

PDL

AXIAL LIVE LOAD


PLL
LATERAL LOAD (0=WIND, 1=SEISMIC)
SEISMIC AXIAL LOAD, SD
PLAT

=
=

-80

kips

SEISMIC SHEAR LOAD, SD

14.9

kips

VLAT

5.1

COL#2
35
kips

kips
1

4.3
kips
Seismic, SD
80
kips
18.8

STEEL COLUMN WIDTH

c1

10.1

STEEL COLUMN DEPTH

c2

8.02

in

BASE PLATE WIDTH

b1

18

in

BASE PLATE DEPTH

b2

18

in

CONCRETE STRENGTH

fc '

ksi

REBAR YIELD STRESS

fy

60

ksi

ALLOWABLE SOIL PRESSURE

Qa

ksf

L1

ft

DISTANCE BETWEEN COLUMNS

S1

20

ft

16

ft

20

ft

S3
DISTANCE TO RIGHT EDGE

L2

ft

FOOTING WIDTH

7.5

ft

FTG EMBEDMENT DEPTH

Df

ft

24

in

SURCHARGE

qs

0.1

ksf

SOIL WEIGHT

ws

0.11

kcf

#
#

8
5

=
=
=

66.00
7.50
24

FOOTING THICKNESS

LONGITUDINAL REINFORCING BAR SIZE


TRANSVERSE REINFORCING BAR SIZE

kips

2.3

kips

-75
15.9

COL#4
18
kips

<== Input 0 , if no column. Typical

2.3

kips

<== Non concurrent roof live load & lateral

kips

75

kips

<== Negative value for uplift

kips

17.1

kips

in

DISTANCE TO LEFT EDGE

S2

COL#3
39
kips

BAND WIDTH

be =

LONG. REINF AT TOP


LONG. REINF AT BOTTOM
TRANS. REINF. AT BAND WIDTH

5 # 8 @ 20 in o.c., cont.
13 # 8 @ 7 in o.c., cont.
7 # 5 @ 14 in o.c., bottom

7.5

ft, for each col.

DESIGN SUMMARY
FOOTING LENGTH
FOOTING WIDTH
FOOTING THICKNESS

L
B
T

ft
ft
in

THE FOOTING DESIGN IS ADEQUATE.

ANALYSIS
DESIGN LOADS AT TOP OF GRADE BEAM (IBC SEC.1605.3.2 & ACI 318 SEC.9.2.1)
SERVICE LOADS
CASE 1 : DL + LL

P=

COL # 1
20
k

COL # 2
39
k

COL # 3
41
k

COL #4
20
k
( e=

CASE 2 : DL + LL + E / 1.4

CASE 3 : 0.9 DL + E / 1.4

FACTORED LOADS
CASE 1 : 1.2 DL + 1.6 LL

P=

-37

96

-12

74

V=

11

13

11

12

P=

-44

89

-18

70

V=

11

13

11

12

Pu =

26

49

50

25

( e=

121.0
18.48
47.6

k
ft, fr CL of GB )
k

( e=

96.3
24.08
47.6

k
ft, fr CL of GB )
k

150.8
-0.08

k
ft, fr CL of GB )

( eu =

142.4
22.08
66.7

k
ft, fr CL of GB )
k

( eu =

96.3
33.28
66.7

k
ft, fr CL of GB )
k

( eu =
CASE 2 : 1.2 DL + 1.0 LL + 1.0 E

CASE 3 : 0.9 DL + 1.0 E

Pu =

-57

126

-26

99

Vu =

15

19

16

17

Pu =

-67

112

-40

91

Vu =

15

19

16

17

CHECK OVERTURNING FACTOR (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
>
MR / MO =
3.13
F = 0.75 / 0.9 =
0.83
[Satisfactory]
Where MO =
(VLAT 1 + VLAT 2 + VLAT 3 + VLAT 4) T - PLAT 1(L - L1) - PLAT 2(S2 + S3 + L2) - PLAT 3(S3 + L2) - PLAT 4 L2 =
Pftg =
(0.15 kcf) T B L =
148.50
k, footing weight
Psoil =
w s (Df - T) B L =
54.45
k, soil weight
MR =
PDL 1(L - L1) + PDL 2(S2 + S3 + L2) + PDL 3(S3 + L2) + PDL 4 L2 + 0.5 (Pftg + Psoil) L =
10112

__
Page 23 of 533
524

3233

k-ft

TOTAL
121.0 k
0.18
ft, fr CL of GB )

k-ft

(cont'd)

CHECK SOIL BEARING CAPACITY (ACI 318 SEC.15.2.2)


Service Loads
P
e
qs B L
(0.15-w s)T B L

CASE 1
121.0
0.2
49.5
39.6

P
e
qmax
qallow

210.1
0.1
0.4
2.0

( P )

Where

q MAX =

1+

CASE 2
121.0
19.3
49.5
39.6
210.1
11.1
0.9
2.7

< L/6

6e
L

BL
2 ( P )

3 B(0.5 L e )

CASE 3
96.3
25.1
0.0
35.6
131.9
18.3
0.8
2.7

> L/6

k
ft, (at base, including V T / P)
k, (surcharge load)
k, (footing increased)
k
ft
ksf
ksf

> L/6

[Satisfactory]

,
,

for
for

L
6
L
e>
6
e

DESIGN FLEXURE & CHECK FLEXURE SHEAR


(ACI 318 SEC.15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, 12.5, 15.5.2, 11.1.3.1, & 11.2)

( Pu )
qu, MAX =

1+

6eu
L

BL
2 ( Pu )

3B(0.5L eu)

L
, for eu
6
L
, for eu >
6

0.85 f c 1
'

T 4
MIN = MIN 0.0018 ,
d 3

FACTORED SOIL PRESSURE


Factored Loads
CASE 1

0.85 1 f c
u
f y
u +t
'

MAX =

Mu
'
0.383bd 2 f c

f y

CASE 2

CASE 3

Pu

150.8

142.4

96.3

eu

-0.1

23.0

34.7

ft, (at base, including Vu T / Pu)

qs B L

79.2

49.5

0.0

[0.15 T + w s (Df - T)] B L

243.5

243.5

182.7

Pu
eu
qu, max

473.5
0.0
0.954

435.4
< L/6

7.5

279.0
< L/6

12.0

1.482

FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 1


Section
0
mid L1
C 1 left C 1 right mid S1
C 2 left
Xu (ft)
0
2.50
5.00
5.00
15.00
25.00
0
0
0
0
-262
-523
Mu,col (ft-k)
Vu,col (k)
0
0.0
0.0
26.2
26.2
26.2
Pu,surch (klf)
1.20
1.20
1.20
1.20
1.20
1.20
0
-4
-15
-15
-135
-375
Mu,surch (ft-k)
Vu,surch (k)
0
3.0
6.0
6.0
18.0
30.0
3.69
3.69
3.69
3.69
3.69
3.69
Pu,ftg & fill (klf)
0
-12
-46
-46
-415
-1153
Mu,ftg & fill (ft-k)
0
9.2
18.5
18.5
55.4
92.3
Vu,ftg & fill (k)
0.96
0.96
0.96
0.96
0.96
0.96
qu,soil (ksf)
0
22
90
90
809
2246
Mu,soil (ft-k)
0
-18.0
-35.9
-35.9
-107.8
-179.6
Vu,soil (k)
Mu (ft-k)
0
7
29
29
-3
195
Vu (kips)
0
-5.8
-11.5
14.7
-8.3
-31.2

k, (factored surcharge load)


k, (factored footing & backfill loads)
k
> L/6

ft

1.179

C 2 right
25.00
-523
75.0
1.20
-375
30.0
3.69
-1153
92.3
0.96
2246
-179.6
195
17.7

mid S2
33.00
-1,124
75.0
1.20
-653
39.6
3.69
-2009
121.8
0.96
3913
-237.0
126
-0.6

C 3 left
41.00
-1,724
75.0
1.20
-1009
49.2
3.69
-3101
151.3
0.96
6038
-294.4
205
-18.9

ksf

C 3 right
41.00
-1,724
125.5
1.20
-1009
49.2
3.69
-3101
151.3
0.96
6038
-294.4
205
31.6

mid S3
51.00
-2,979
125.5
1.20
-1561
61.2
3.69
-4799
188.2
0.96
9341
-366.1
3
8.8

C 4 left
61.00
-4,234
125.5
1.20
-2233
73.2
3.69
-6865
225.1
0.95
13360
-437.7
28
-13.9

C 4 right
61.00
-4,234
150.8
1.20
-2233
73.2
3.69
-6865
225.1
0.95
13360
-437.7
28
11

mid L2
63.50
-4,611
150.8
1.20
-2419
76.2
3.69
-7440
234.3
0.95
14477
-455.6
7
5.7

250
200
150
100
50

0
-50

40
20
0
-20
-40

__
Page 24 of 533
524

L
66.00
-4,988
150.8
1.20
-2614
79.2
3.69
-8037
243.5
0.95
15639
-473.5
0
0.0

(cont'd)
FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 2
0
mid L1
C 1 left C 1 right mid S1
C 2 left
Section
0
2.50
5.00
5.00
15.00
25.00
Xu (ft)
Mu,col (ft-k)
0
0
0
30
599
1,168
Vu,col (k)
0
0.0
0.0
-56.9
-56.9
-56.9
Pu,surch (klf)
0.75
0.75
0.75
0.75
0.75
0.75
Mu,surch (ft-k)
0
-2
-9
-9
-84
-234
0
1.9
3.8
3.8
11.3
18.8
Vu,surch (k)
3.69
3.69
3.69
3.69
3.69
3.69
Pu,ftg & fill (klf)
0
-12
-46
-46
-415
-1153
Mu,ftg & fill (ft-k)
0
9.2
18.5
18.5
55.4
92.3
Vu,ftg & fill (k)
0.28
0.32
0.37
0.37
0.55
0.73
qu,soil (ksf)
0
7
29
29
311
1007
Mu,soil (ft-k)
0
-5.6
-12.1
-12.1
-46.6
-94.8
Vu,soil (k)
Mu (ft-k)
0
-7
-27
3
411
787
Vu (kips)
0
5.5
10.1
-46.8
-36.9
-40.7

C 2 right
25.00
1,205
69.4
0.75
-234
18.8
3.69
-1153
92.3
0.73
1007
-94.8
825
85.6

mid S2
33.00
650
69.4
0.75
-408
24.8
3.69
-2009
121.8
0.88
1953
-143.2
186
72.7

C 3 left
41.00
95
69.4
0.75
-630
30.8
3.69
-3101
151.3
1.03
3322
-200.4
-315
51.1

C 3 right
41.00
127
43.5
0.75
-630
30.8
3.69
-3101
151.3
1.03
3322
-200.4
-283
25.2

mid S3
51.00
-308
43.5
0.75
-975
38.3
3.69
-4799
188.2
1.21
5733
-284.1
-349
-14.2

C 4 left
61.00
-743
43.5
0.75
-1395
45.8
3.69
-6865
225.1
1.39
9050
-381.6
46
-67.2

C 4 right
61.00
-709
142.4
0.75
-1395
45.8
3.69
-6865
225.1
1.39
9050
-381.6
81
31.7

mid L2
63.50
-1,065
142.4
0.75
-1512
47.6
3.69
-7440
234.3
1.44
10037
-408.1
20
16.3

L
66.00
-1,421
142.4
0.75
-1634
49.5
3.69
-8037
243.5
1.48
11091
-435.4
0
0.0

1000
500
0

-500

100
50
0

-50
-100

FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 3


0
mid L1
C 1 left C 1 right mid S1
C 2 left
Section
0
2.50
5.00
5.00
15.00
25.00
Xu (ft)
0
0
0
30
695
1,360
Mu,col (ft-k)
0
0.0
0.0
-66.5
-66.5
-66.5
Vu,col (k)
0.00
0.00
0.00
0.00
0.00
0.00
Pu,surch (klf)
0
0
0
0
0
0
Mu,surch (ft-k)
0
0.0
0.0
0.0
0.0
0.0
Vu,surch (k)
2.77
2.77
2.77
2.77
2.77
2.77
Pu,ftg & fill (klf)
0
-9
-35
-35
-311
-865
Mu,ftg & fill (ft-k)
0
6.9
13.8
13.8
41.5
69.2
Vu,ftg & fill (k)
0.00
0.00
0.04
0.04
0.23
0.41
qu,soil (ksf)
0
0
0
0
41
252
Mu,soil (ft-k)
0
0.0
-0.3
-0.3
-10.3
-34.2
Vu,soil (k)
Mu (ft-k)
0
-9
-34
-5
425
747
Vu (kips)
0
6.9
13.5
-53.0
-35.3
-31.5

C 2 right
25.00
1,397
45.0
0.00
0
0.0
2.77
-865
69.2
0.41
252
-34.2
785
80.0

mid S2
33.00
1,037
45.0
0.00
0
0.0
2.77
-1507
91.3
0.56
637
-63.5
168
72.8

C 3 left
41.00
677
45.0
0.00
0
0.0
2.77
-2326
113.5
0.71
1292
-101.7
-357
56.8

C 3 right
41.00
709
5.1
0.00
0
0.0
2.77
-2326
113.5
0.71
1292
-101.7
-325
16.9

mid S3
51.00
658
5.1
0.00
0
0.0
2.77
-3599
141.1
0.90
2599
-162.1
-342
-15.9

C 4 left
61.00
607
5.1
0.00
0
0.0
2.77
-5149
168.8
1.09
4581
-236.5
39
-62.6

C 4 right
61.00
641
96.3
0.00
0
0.0
2.77
-5149
168.8
1.09
4581
-236.5
73
28.6

1000
800
600
400
200
0
-200
-400
-600

mid L2
63.50
401
96.3
0.00
0
0.0
2.77
-5580
175.7
1.13
5198
-257.3
19
14.7

L
66.00
160
96.3
0.00
0
0.0
2.77
-6028
182.7
1.18
5868
-279.0
0
0.0

100
50
0

-50
-100

DESIGN FLEXURE
Location

Mu,max

Top Longitudinal
Bottom Longitudinal

-357
825

Bottom Transverse, be

d (in)

min

reqD

max

smax(in)

use

provD

ft-k
ft-k

21.50
20.50

0.0020
0.0021

0.0019
0.0052

0.0155
0.0155

no limit
18

5 # 8 @ 20 in o.c., cont.
13 # 8 @ 7 in o.c., cont.

0.0020
0.0056

ft-k / ft

19.69

0.0011

0.0001

0.0155

18

7 # 5 @ 14 in o.c.

0.0012

__
Page 25 of 533
524

[Satisfactory]

(cont'd)
CHECK FLEXURE SHEAR
Direction

Vc = 2 b d (fc')0.5

Vu,max

Longitudinal
Transverse

86
1

k
k / ft

152
19

check Vu < Vc

k
k / ft

[Satisfactory]
[Satisfactory]

CHECK PUNCHING SHEAR (ACI 318 SEC.15.5.2, 11.11.1.2, 11.11.6, & 13.5.3.2)

v u ( psi ) =
J =
R=

3
d b1
6

P u R 0.5 v M ub1
+
J
AP
1+

b1

+3

A P = 2 ( b1 + b 2 ) d
1
v = 1
2
b1
1+
3 b2
A f = Bb e

b2
b1

P ub1b2
Af
Column
Col. 1

Col. 2

Col. 3

Col. 4

Case
1
2
3
1
2
3
1
2
3
1
2
3

Pu
26.2
0.0
0.0
48.9
126.3
111.5
50.5
0.0
0.0
25.3
98.9
91.2

Mu
0.0
14.9
14.9
0.0
18.8
18.8
0.0
15.9
15.9
0.0
17.1
17.1

b1
33.7
33.7
33.7
33.7
33.7
33.7
33.7
33.7
33.7
33.7
33.7
33.7

b2
32.7
32.7
32.7
32.7
32.7
32.7
32.7
32.7
32.7
32.7
32.7
32.7

v
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

c
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3

vc( psi ) = ( 2 + y )
y = MIN 2,
b0 =

y
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

, 40

f 'c
d
b0

AP
, b1 = ( c1 + d ) , b 2 = ( c 2 + d )
d

Af
56.3
56.3
56.3
56.3
56.3
56.3
56.3
56.3
56.3
56.3
56.3
56.3

Ap
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2

R
3.6
0.0
0.0
6.7
17.2
15.2
6.9
0.0
0.0
3.4
13.5
12.4

J
25.8
25.8
25.8
25.8
25.8
25.8
25.8
25.8
25.8
25.8
25.8
25.8

vu (psi)
8.6
2.3
2.3
16.1
44.6
39.7
16.7
2.4
2.4
8.3
35.3
32.7

vc
164.3
164.3
164.3
164.3
164.3
164.3
164.3
164.3
164.3
164.3
164.3
164.3

[Satisfactory]

__
Page 26 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Grade Beam Design for Moment Resisting Frame Based on ACI 318-08
INPUT DATA

COL#1

COL#2

COL#3

COL#4

PDL =

15

kips

PLL =
AXIAL LIVE LOAD
LATERAL LOAD (0=WIND, 1=SEISMIC)
PLAT =
SEISMIC AXIAL LOAD, SD

5.1
10

kips
1
kips

12

kips

SEISMIC BENDING LOAD, SD

MLAT =

295

ft-kips

501.5

ft-kips

531

ft-kips

324.5

ft-kips

SEISMIC SHEAR LOAD, SD

kips

18.8

kips

15.9

kips

17.1

kips

AXIAL DEAD LOAD

35

kips

39

kips

18

kips

<== Input 0 , if no column. Typical

4.3
kips
Seismic, SD
15
kips

2.3

kips

2.3

kips

<== Non concurrent roof live load & lateral

kips

<== Negative value for uplift

25

VLAT =

14.9

COLUMN WIDTH

c1 =

36

in

36

in

36

in

36

in

COLUMN DEPTH

c2 =

24

in

24

in

24

in

24

in

CONCRETE STRENGTH

fc'

ksi

fy

60

ksi

Qa

ksf

DISTANCE TO LEFT EDGE

L1

ft

DISTANCE BETWEEN COLUMNS

S1

20

ft

S2

16

ft

S3

20

ft
ft

REBAR YIELD STRESS


ALLOWABLE SOIL PRESSURE

DISTANCE TO RIGHT EDGE

L2

FOOTING WIDTH

ft

Df

ft

FTG EMBEDMENT DEPTH


FOOTING THICKNESS

24

in

SURCHARGE

qs

0.1

ksf

SOIL WEIGHT

ws

kcf

0.11

LONGITUDINAL REINFORCING BAR SIZE

TRANSVERSE REINFORCING BAR SIZE

DESIGN SUMMARY

BAND WIDTH

be =

LONG. REINF AT TOP


LONG. REINF AT BOTTOM

6 # 8 @ 8 in o.c., cont.
6 # 8 @ 8 in o.c., cont.
4 # 5 @ 14 in o.c., bottom

FOOTING LENGTH

60.00

ft

TRANS. REINF. AT BAND WIDTH

FOOTING WIDTH
FOOTING THICKNESS

B
T

=
=

4.00
24

ft
in

THE FOOTING DESIGN IS ADEQUATE.

4.0

ft, for each col.

ANALYSIS
DESIGN LOADS AT TOP OF GRADE BEAM (IBC SEC.1605.3.2 & ACI 318 SEC.9.2.1)
SERVICE LOADS

COL # 1

CASE 1 : DL + LL

P=

20

COL # 2
k

39

COL # 3
k

41

COL #4
k

20

TOTAL
k
( e=

CASE 2 : DL + LL + E / 1.4

50

50

38

165.3

ft-k

358

ft-k

379

232

ft-k

1180.0 ft-k

V=

11

13

11

12

21

42

44

34

140.6

ft-k

358

ft-k

379

232

ft-k

1180.0 ft-k

V=

11

13

11

12

Pu =

26

49

50

25

11.15

ft, fr CL of GB )

47.6

150.8

-0.08

ft, fr CL of GB )
k

Pu =

33

61

61

49

204.4

Mu =

295

ft-k

502

ft-k

531

325

ft-k

1652.0 ft-k

Vu =

15

19

16

17

Pu =

10.24

ft, fr CL of GB )

66.7

k
k

24

47

47

41

158.3

295

ft-k

502

ft-k

531

325

ft-k

1652.0 ft-k

15

19

16

17

455

k-ft

__

CHECK OVERTURNING FACTOR (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
MR / MO =
>
15.04
F = 0.75 / 0.9 =
0.83
[Satisfactory]
MLAT + ( VLAT ) Df - PLAT 1(L - L1) - PLAT 2(S2 + S3 + L2) - PLAT 3(S3 + L2) - PLAT 4 L2 =
Where MO =
Psoil =
MR =

211

Vu =

(0.15 kcf) T B L =
ws (Df - T) B L =

ft, fr CL of GB )

47.6

P=

Mu =

Pftg =

8.98

M=

( eu =

CASE 3 : 0.9 DL + 1.0 E

27
211

( eu =
CASE 2 : 1.2 DL + 1.0 LL + 1.0 E

ft, fr CL of GB )

P=

( e=

FACTORED LOADS
CASE 1 : 1.2 DL + 1.6 LL

0.18

M=

( e=

CASE 3 : 0.9 DL + E / 1.4

121.0

72.00

( eu =

k, footing weight

52.80
k, soil weight
PDL 1(L - L1) + PDL 2(S2 + S3 + L2) + PDL 3(S3 + L2) + PDL 4 L2 + 0.5 (Pftg + Psoil) L =

Page 27 of 533
524

6838

k-ft

13.60

ft, fr CL of GB )

66.7

(cont'd)
CHECK SOIL BEARING CAPACITY (ACI 318 SEC.15.2.2)
Service Loads

CASE 1

CASE 2

CASE 3

121.0

165.3

140.6

e
qs B L

0.2
24.0

9.6
24.0

11.8
0.0

ft, (at base, including V T / P)


k, (surcharge load)

(0.15-ws)T B L

19.2

19.2

17.3

164.2

208.5

157.9

e
qmax

0.1
0.7

qallow

2.0

( P )

Where

q MAX =

1+

< L/6

7.6
1.5

< L/6

10.5
1.4

2.7

6e
L

k, (footing increased)
k
> L/6

ft
ksf

2.7

ksf

[Satisfactory]

BL
2 ( P )
,
3 B(0.5 L e )

for
for

L
6
L
e>
6
e

DESIGN FLEXURE & CHECK FLEXURE SHEAR


(ACI 318 SEC.15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, 12.5, 15.5.2, 11.1.3.1, & 11.2)

( Pu )
qu,MAX =

1+

6eu
L

BL
2 ( Pu )

3B(0.5L eu)

0.85 1 f c
'

L
, for eu
6

MAX =

L
, for eu >
6

f y

u
u +t

Mu
'
0.85 f c 1 1
'
0.383bd 2 f c
=
f y

T 4
MIN = MIN 0.0018 ,
d 3

FACTORED SOIL PRESSURE


Factored Loads
CASE 1

CASE 2

CASE 3

Pu

150.8

204.4

158.3

eu

-0.1

10.9

14.4

ft, (at base, including Vu T / Pu)

qs B L

38.4

24.0

0.0

[0.15 T + ws (Df - T)] B L

149.8

149.8

112.3

Pu

339.0

eu

0.0

qu, max

378.2
< L/6

5.9

1.407

270.6
< L/6

8.4

2.503

FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 1


mid L1 C 1 left C 1 right mid S1 C 2 left
Section
0
Xu (ft)
0
1.00
2.00
2.00
12.00
22.00

k, (factored surcharge load)


k, (factored footing & backfill loads)
k
< L/6

ft

2.080

ksf

C 2 right
22.00

mid S2
30.00

C 3 left
38.00

C 3 right
38.00

mid S3
48.00

C 4 left
58.00

C 4 right
58.00

mid L2
59.00

L
60.00

Mu,col (ft-k)

-262

-523

-523

-1,124

-1,724

-1,724

-2,979

-4,234

-4,234

-4,385

-4,536

Vu,col (k)

0.0

0.0

26.2

26.2

26.2

75.0

75.0

75.0

125.5

125.5

125.5

150.8

150.8

150.8

Pu,surch (klf)

0.64

0.64

0.64

0.64

0.64

0.64

0.64

0.64

0.64

0.64

0.64

0.64

0.64

0.64

0.64

Mu,surch (ft-k)

-1

-1

-46

-155

-155

-288

-462

-462

-737

-1076

-1076

-1114

-1152

Vu,surch (k)

0.6

1.3

1.3

7.7

14.1

14.1

19.2

24.3

24.3

30.7

37.1

37.1

37.8

38.4

Pu,ftg & fill (klf)

2.496

2.496

2.496

2.496

2.496

2.496

2.496

2.496

2.496

2.496

2.496

2.496

2.496

2.496

2.496

Mu,ftg & fill (ft-k)

-1

-5

-5

-180

-604

-604

-1123

-1802

-1802

-2875

-4198

-4198

-4344

-4493

Vu,ftg & fill (k)

2.5

5.0

5.0

30.0

54.9

54.9

74.9

94.8

94.8

119.8

144.8

144.8

147.3

149.8

qu,soil (ksf)

1.42

1.42

1.42

1.42

1.42

1.41

1.41

1.41

1.41

1.41

1.41

1.41

1.41

1.41

1.41

Mu,soil (ft-k)

11

11

408

1371

1371

2548

4087

4087

6519

9514

9514

9844

10181

Vu,soil (k)

-5.7

-11.3

-11.3

-68.0

-124.6

-124.6

-169.8

-214.9

-214.9

-271.4

-327.7

-327.7

-333.3

-339.0

M u (ft-k)
Vu (kips)

-79

89

89

13

99

99

-73

-2.5

-5.1

21.1

-4.2

-29.4

19.5

-0.7

-20.7

29.7

4.7

-20.3

2.5

0.0

150
100
50
0
-50
-100

40
20
0
-20
-40

__
Page 28 of 533
524

(cont'd)
FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 2
mid L1 C 1 left C 1 right mid S1 C 2 left
0
Section
0
1.00
2.00
2.00
12.00
22.00
Xu (ft)

C 2 right
22.00

mid S2
30.00

C 3 left
38.00

C 3 right
38.00

mid S3

C 4 left
58.00

C 4 right
58.00

mid L2

48.00

59.00

L
60.00

Mu,col (ft-k)

325

-6

-337

202

-553

-1,309

-746

-2,301

-3,856

-3,497

-3,701

-3,906

Vu,col (k)

0.0

0.0

33.1

33.1

33.1

94.4

94.4

94.4

155.5

155.5

155.5

204.4

204.4

204.4

Pu,surch (klf)

0.40

0.40

0.40

0.40

0.40

0.40

0.40

0.40

0.40

0.40

0.40

0.40

0.40

0.40

0.40

Mu,surch (ft-k)

-1

-1

-29

-97

-97

-180

-289

-289

-461

-673

-673

-696

-720

Vu,surch (k)

0.4

0.8

0.8

4.8

8.8

8.8

12.0

15.2

15.2

19.2

23.2

23.2

23.6

24.0

Pu,ftg & fill (klf)

2.496

2.50

2.50

2.50

2.50

2.50

2.50

2.50

2.50

2.50

2.50

2.50

2.50

2.50

2.50

Mu,ftg & fill (ft-k)

-1

-5

-5

-180

-604

-604

-1123

-1802

-1802

-2875

-4198

-4198

-4344

-4493

Vu,ftg & fill (k)

2.5

5.0

5.0

30.0

54.9

54.9

74.9

94.8

94.8

119.8

144.8

144.8

147.3

149.8

qu,soil (ksf)

0.65

0.68

0.71

0.71

1.02

1.33

1.33

1.58

1.82

1.82

2.13

2.44

2.44

2.47

2.50

Mu,soil (ft-k)

222

847

847

1723

3003

3003

5266

8382

8382

8745

9119

Vu,soil (k)

-2.7

-5.4

-5.4

-40.0

-87.0

-87.0

-133.4

-187.8

-187.8

-266.9

-358.4

-358.4

-368.2

-378.2

M u (ft-k)
Vu (kips)

324

-191

348

-133

-397

166

-371

-345

14

0.2

0.4

33.5

27.8

9.9

71.2

47.9

16.6

77.7

27.6

-34.9

14.0

7.1

0.0

400
200
0
-200

-400
-600

100
50

0
-50

FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 3


mid L1 C 1 left C 1 right mid S1 C 2 left
0
Section
Xu (ft)
0
1.00
2.00
2.00
12.00
22.00

C 2 right
22.00

mid S2
30.00

C 3 left
38.00

C 3 right
38.00

mid S3
48.00

C 4 left
58.00

C 4 right
58.00

mid L2
59.00

L
60.00

Mu,col (ft-k)

325

90

-145

394

-166

-726

-163

-1,334

-2,505

-2,147

-2,305

-2,463

Vu,col (k)

0.0

0.0

23.5

23.5

23.5

70.0

70.0

70.0

117.1

117.1

117.1

158.3

158.3

158.3

Pu,surch (klf)

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

Mu,surch (ft-k)

Vu,surch (k)

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

Pu,ftg & fill (klf)

1.87

1.87

1.87

1.87

1.87

1.87

1.87

1.87

1.87

1.87

1.87

1.87

1.87

1.87

1.87

Mu,ftg & fill (ft-k)

-1

-4

-4

-135

-453

-453

-842

-1352

-1352

-2157

-3149

-3149

-3258

-3370
112.3

Vu,ftg & fill (k)

1.9

3.7

3.7

22.5

41.2

41.2

56.2

71.1

71.1

89.9

108.6

108.6

110.4

qu,soil (ksf)

0.18

0.21

0.24

0.24

0.56

0.87

0.87

1.13

1.38

1.38

1.70

2.02

2.02

2.05

2.08

Mu,soil (ft-k)

87

395

395

887

1667

1667

3148

5308

5308

5566

5833

Vu,soil (k)

-0.8

-1.7

-1.7

-17.6

-46.1

-46.1

-78.2

-118.3

-118.3

-179.9

-254.2

-254.2

-262.4

-270.6

M u (ft-k)
Vu (kips)

-1

-2

323

42

-203

336

-122

-410

152

-343

-346

13

1.1

2.1

25.6

28.4

18.5

65.0

48.0

22.8

69.9

27.0

-28.6

12.6

6.4

0.0

400
300
200
100
0
-100
-200
-300
-400
-500

80
60
40
20

0
-20
-40

DESIGN FLEXURE
Location

__

d (in)

min

reqD

max

smax(in)

use

provD

Top Longitudinal

-410

ft-k

21.50

0.0020

0.0043

0.0155

no limit

6 # 8 @ 8 in o.c., cont.

0.0046

Bottom Longitudinal

348

ft-k

20.50

0.0021

0.0040

0.0155

18

6 # 8 @ 8 in o.c., cont.

0.0048

ft-k / ft

19.69

0.0005

8.1E-05

0.0155

18

4 # 5 @ 14 in o.c.

0.0013

Bottom Transverse, be

Mu,max

Page 29 of 533
524

[Satisfactory]

(cont'd)
CHECK FLEXURE SHEAR
Vc = 2 b d (fc')0.5

Vu,max

Direction

check Vu < Vc

Longitudinal

78

81

[Satisfactory]

Transverse

k / ft

19

k / ft

[Satisfactory]

CHECK PUNCHING SHEAR (ACI 318 SEC.15.5.2, 11.11.1.2, 11.11.6, & 13.5.3.2)

P u R 0.5 v M ub1
+
J
AP
2
3
d b1
d
b
1+
+3 2
J=
6
b1
b1

A P = 2 ( b1 + b 2 ) d

v u ( psi) =

R=

v = 1

Col. 1

Col. 2

Col. 3

Col. 4

1+

2
3

y = MIN 2,

b1
b2

A f = Bb e

P ub1b2
Af
Column

vc( psi ) = ( 2 + y )

b0 =

, 40

'
fc
d
b0

AP
, b1 = ( c1 + d ) , b 2 = ( c2 + d )
d

Case

Pu

Mu

b1

b2

Af

Ap

vu (psi)

vc

1
2
3
1
2
3
1
2
3
1
2
3

26.2
33.1
23.5
48.9
61.3
46.5
50.5
61.1
47.1
25.3
48.9
41.2

0.0
309.9
309.9
0.0
520.3
520.3
0.0
546.9
546.9
0.0
341.6
341.6

55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7

43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7
43.7

0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0
16.0

27.2
27.2
27.2
27.2
27.2
27.2
27.2
27.2
27.2
27.2
27.2
27.2

27.6
35.0
24.8
51.6
64.7
49.1
53.3
64.5
49.7
26.7
51.6
43.5

95.1
95.1
95.1
95.1
95.1
95.1
95.1
95.1
95.1
95.1
95.1
95.1

-0.4
22.1
22.2
-0.7
37.0
37.2
-0.7
38.9
39.1
-0.4
24.2
24.3

164.3
164.3
164.3
164.3
164.3
164.3
164.3
164.3
164.3
164.3
164.3
164.3

[Satisfactory]

__
Page 30 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Combined Footing Design Based on ACI 318-08


INPUT DATA

c1
c2

COLUMN WIDTH

COL#1

COL#2

18

18

in

18
13

18
26

in
k
k

COLUMN DEPTH
AXIAL DEAD LOAD

PDL

=
=

AXIAL LIVE LOAD

PLL

6.25

12.5

1
-300

Seismic SD
300
k

LATERAL LOAD (0=WIND, 1=SEISMIC)


SEISMIC AXIAL LOAD, SD

PLAT

=
=

SEISMIC SHEAR LOAD, SD

VLAT

12.5

13.75

SEISMIC MOMENT, SD

MLAT

4.578

4.578

k-ft

fc'

ksi

CONCRETE STRENGTH

fy

60

ksi

Qa

ksf

DISTANCE TO LEFT EDGE

L1

36

ft

DISTANCE BETWEEN COLUMNS

30

ft

DISTANCE TO RIGHT EDGE

S
L2

36

ft

FOOTING WIDTH

7.5

ft

Df

ft

48

in

SURCHARGE

qs

0.1

ksf

SOIL WEIGHT

ws

0.11

kcf

LONGITUDINAL REINFORCING BAR SIZE

10

TRANSVERSE REINFORCING BAR SIZE

REBAR YIELD STRESS


ALLOWABLE SOIL PRESSURE

FTG EMBEDMENT DEPTH


FOOTING THICKNESS

BAND WIDTH

be =

LONG. REINF AT TOP

10 # 10 @ 9 in o.c., cont.

7.5

ft

LONG. REINF AT BOTTOM

13 # 10 @ 7 in o.c., cont.

TRANS. REINF. AT BAND WIDTH

8 # 5 @ 12 in o.c., bottom

DESIGN SUMMARY
FOOTING LENGTH

FOOTING WIDTH
FOOTING THICKNESS

B
T

=
=

102.00 ft
7.50
48

ft
in

THE FOOTING DESIGN IS ADEQUATE.

ANALYSIS
DESIGN LOADS AT TOP OF FOOTING (IBC SEC.1605.3.2 & ACI 318 SEC.9.2.1)
SERVICE LOADS

COL # 1

CASE 1 : DL + LL

19

COL # 2
k

39

TOTAL
k

58
(e

CASE 2 : DL + LL + E / 1.4

5.00

-195

253

58

12.2

ft-k

13.1

ft-k

10

19

-203

238

35

12.2

ft-k

13.1

ft-k

10

Pu

26

51

25.3
(e

CASE 3 : 0.9 DL + E / 1.4

ft, fr CL ftg )
k
ft-k

116.76 ft, fr CL ftg )

25.3
(e

k
k
ft-k

188.87 ft, fr CL ftg )


19

FACTORED LOADS
CASE 1 : 1.2 DL + 1.6 LL

( eu
CASE 2 : 1.2 DL + 1.0 LL + 1.0 E

66

-278

344

17.1

ft-k

18.3

ft-k

Vu

13

14

26

Pu

-288

323

35

Mu

17.1

ft-k

18.3

ft-k

Vu

13

14

CHECK OVERTURNING FACTOR (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
MR / MO =
>
3.24
F = 0.75 / 0.9 =
0.83
[Satisfactory]

Psoil =
MR =

k
ft, fr CL ftg )

Pu

( eu

Where MO =
Pftg =

77
5.00

Mu

( eu
CASE 3 : 0.9 DL + 1.0 E

__

MLAT 1 + MLAT 2 + (VLAT 1 + VLAT 2) T - PLAT 1(L - L1) - PLAT 2L2 =


(0.15 kcf) T B L =
459.00 k, footing weight
ws (Df - T) B L =
84.15
k, soil weight
PDL 1(L - L1) + PDL 2L2 + 0.5 (Pftg + Psoil) L =

29495

9114

k-ft

Page 31 of 533
524

k-ft

35.4 ft-k
142.84 ft, fr CL ftg )

35.4 ft-k
262.42 ft, fr CL ftg )
26

(cont'd)
CHECK SOIL BEARING CAPACITY (ACI 318 SEC.15.2.2)
Service Loads

CASE 1

CASE 2

57.8

57.8

35.1

e
qs B L

5.0
76.5

118.1
76.5

191.0
0.0

ft, (at base, including V T / P)


k, (surcharge load)

(0.15-ws)T B L

122.4

122.4

110.2

256.7

256.7

145.3

e
qmax

1.1
0.4

qallow

2.0

( P )

Where

q MAX =

1+

< L/6

CASE 3

26.6
0.9

> L/6

46.2
2.7

2.7

6e
L

k, (footing increased)
k
> L/6

ft
ksf

2.7

ksf

[Satisfactory]

L
6
L
e>
6
e

for

BL
2 ( P )
,
3 B(0.5 L e )

for

DESIGN FLEXURE & CHECK FLEXURE SHEAR


(ACI 318 SEC.15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, 12.5, 15.5.2, 11.1.3.1, & 11.2)

( Pu )
qu,MAX =

1+

6eu
L

BL
2 ( Pu )

3B(0.5L eu)

, for eu

0.85 1 f c
'

L
6

MAX =

L
, for eu >
6

fy

0.85 f c 1 1
'

T 4
MIN = MIN 0.0018 ,
d 3

u
u +t

Mu
0.383bd 2 f 'c

fy

FACTORED SOIL PRESSURE


Factored Loads
Pu

CASE 1
76.8

CASE 2
65.6

CASE 3
35.1

eu

5.0

144.4

265.4

qs B L

122.4

76.5

0.0

[0.15 T + ws (Df - T)] B L

651.8

651.8

488.8

851.0

793.8

523.9

Pu
eu

0.5

qu, max

< L/6

11.9

1.142

< L/6

17.8

1.766

k
ft, (at base, including Vu T / Pu)
k, (factored surcharge load)
k, (factored footing & backfill loads)
k
> L/6

ft

1.402

FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 1


L1 left
L1 right
0.5 L1
Section
0.2 S
0.4 S
0
Xu (ft)
0
18.00
36.00
36.00
42.00
48.00

ksf

0.6 S
54.00

0.8 S
60.00

L2 left
66.00

L2 right
66.00

0.5 L2
84.00

L
102.00

Mu,col (ft-k)

-154

-307

-461

-614

-768

-768

-2,150

-3,533

Vu,col (k)

0.0

0.0

25.6

25.6

25.6

25.6

25.6

25.6

76.8

76.8

76.8

Pu,surch (klf)

1.20

1.20

1.20

1.20

1.20

1.20

1.20

1.20

1.20

1.20

1.20

Mu,surch (ft-k)

-194

-778

-778

-1058

-1382

-1750

-2160

-2614

-2614

-4234

-6242
122.4

1.20

Vu,surch (k)

21.6

43.2

43.2

50.4

57.6

64.8

72.0

79.2

79.2

100.8

Pu,ftg & fill (klf)

6.39

6.39

6.39

6.39

6.39

6.39

6.39

6.39

6.39

6.39

6.39

6.39

Mu,ftg & fill (ft-k)

-1035

-4141

-4141

-5636

-7361

-9317

-11502

-13917

-13917

-22544

-33241

Vu,ftg & fill (k)

115.0

230.0

230.0

268.4

306.7

345.1

383.4

421.7

421.7

536.8

651.8

qu,soil (ksf)

1.08

1.09

1.10

1.10

1.11

1.11

1.11

1.12

1.12

1.12

1.13

1.14

Mu,soil (ft-k)

1320

5296

5296

7217

9436

11955

14775

17897

17897

29082

43016

Vu,soil (k)

-146.9

-295.2

-295.2

-344.9

-394.8

-444.9

-495.1

-545.5

-545.5

-697.5

-851.0

M u (ft-k)
Vu (kips)

90

378

378

369

385

428

499

598

598

154

-10.3

-21.9

3.7

-0.6

-4.9

-9.4

-14.1

-18.9

32.3

16.8

700
600
500
400
300
200
100
0

40
20
0
-20
-40

__
Page 32 of 533
524

(cont'd)
FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 2
0.5 L1
L1 left
L1 right
0
0.2 S
0.4 S
Section
0
18.00
36.00
36.00
42.00
48.00
Xu (ft)

0.6 S
54.00

0.8 S
60.00

L2 left
66.00

L2 right
66.00

0.5 L2
84.00

L
102.00

Mu,col (ft-k)

67

1,736

3,405

5,074

6,743

8,412

8,451

7,305

6,125

Vu,col (k)

0.0

0.0

-278.2

-278.2

-278.2

-278.2

-278.2

-278.2

65.6

65.6

65.6

Pu,surch (klf)

0.75

0.75

0.75

0.75

0.75

0.75

0.75

0.75

0.75

0.75

0.75

Mu,surch (ft-k)

-122

-486

-486

-662

-864

-1094

-1350

-1634

-1634

-2646

-3902

31.5

36.0

40.5

45.0

49.5

49.5

63.0

76.5

6.39

6.39

6.39

6.39

6.39

6.39

6.39

0.75

Vu,surch (k)

13.5

27.0

27.0

Pu,ftg & fill (klf)

6.39

6.39

6.39

6.39

Mu,ftg & fill (ft-k)

-1035

-4141

-4141

-5636

-7361

-9317

-11502

-13917

-13917

-22544

-33241

Vu,ftg & fill (k)

115.0

230.0

230.0

268.4

306.7

345.1

383.4

421.7

421.7

536.8

651.8

qu,soil (ksf)

0.31

0.57

0.82

0.82

0.91

0.99

1.08

1.17

1.25

1.25

1.51

1.77

Mu,soil (ft-k)

480

2337

2337

3370

4649

6196

8035

10188

10188

18770

31017

Vu,soil (k)

-59.1

-153.0

-153.0

-192.0

-234.8

-281.5

-332.1

-386.5

-386.5

-572.8

-793.8

M u (ft-k)
Vu (kips)

-676

-2289

-2222

-1191

-172

859

1925

3049

3088

885

69.4

104.1

-174.1

-170.2

-170.2

-174.1

-181.8

-193.4

150.3

92.5

6.39

4000
3000
2000
1000
0
-1000

-2000
-3000

200
100
0
-100

-200
-300

FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 3


0.5 L1
L1 left
L1 right
0
Section
0.2 S
0.4 S
Xu (ft)
0
18.00
36.00
36.00
42.00
48.00

0.6 S
54.00

0.8 S
60.00

L2 left

L2 right

0.5 L2

66.00

66.00

84.00

L
102.00

Mu,col (ft-k)

67

1797

3527

5256

6986

8716

8,755

8,158

7,526

Vu,col (k)

0.0

0.0

-288.3

-288.3

-288.3

-288.3

-288.3

-288.3

35.1

35.1

35.1

Pu,surch (klf)

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

Mu,surch (ft-k)

Vu,surch (k)

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

Pu,ftg & fill (klf)

4.79

4.79

4.79

4.79

4.79

4.79

4.79

4.79

4.79

4.79

4.79

Mu,ftg & fill (ft-k)

-776

-3106

-3106

-4227

-5521

-6987

-8627

-10438

-10438

-16908

-24931

Vu,ftg & fill (k)

86.3

172.5

172.5

201.3

230.0

258.8

287.6

316.3

316.3

402.6

488.8

qu,soil (ksf)

0.00

0.22

0.47

0.47

0.56

0.64

0.73

0.81

0.90

0.90

1.15

1.40

Mu,soil (ft-k)

68

670

670

1097

1674

2424

3371

4536

4536

9575

17405

Vu,soil (k)

-12.9

-59.8

-59.8

-83.0

-110.0

-140.8

-175.4

-213.8

-213.8

-351.8

-523.9

M u (ft-k)
Vu (kips)

-709

-2435

-2368

-1333

-321

693

1730

2814

2853

824

73.3

112.8

-175.5

-170.0

-168.2

-170.3

-176.1

-185.8

137.6

85.9

0.00

4.79

4000
3000
2000
1000
0

-1000
-2000
-3000

200
100
0
-100
-200
-300

DESIGN FLEXURE
Location

Mu,max

Top Longitudinal

-2435

Bottom Longitudinal

3088

Bottom Transverse, be

ft-k
ft-k

__

ft-k / ft

d (in)

min

reqD

max

smax(in)

use

provD

45.37

0.0019

0.0030

0.0155

no limit

10 # 10 @ 9 in o.c., cont.

0.0031

44.37

0.0019

0.0041

0.0155

18

13 # 10 @ 7 in o.c., cont.

0.0041

43.42

0.0006

6.9E-06

0.0155

18

8 # 5 @ 12 in o.c.

0.0006

Page 33 of 533
524

[Satisfactory]

(cont'd)
CHECK FLEXURE SHEAR
Vc = 2 b d (fc')

Vu,max

Direction
Longitudinal

193

Transverse

check Vu < Vc

0.5

328

[Satisfactory]

k / ft

43

k / ft

[Satisfactory]

CHECK PUNCHING SHEAR (ACI 318 SEC.15.5.2, 11.11.1.2, 11.11.6, & 13.5.3.2)

P u R 0.5 v M ub1
+
J
AP
2
3
d b1
d
b
1+
+3 2
J=
6
b1
b1

A P = 2 ( b1 + b 2 ) d

v u ( psi) =

R=

v = 1

Col. 1

Col. 2

1+

2
3

y = MIN 2,

b1
b2

A f = Bb e

P ub1b2
Af
Column

vc( psi ) = ( 2 + y )

b0 =

, 40

'
fc
d
b0

AP
, b1 = ( c1 + d ) , b 2 = ( c2 + d )
d

Case

Pu

Mu

b1

b2

Af

Ap

vu (psi)

vc

25.6

0.0

61.4

61.4

0.4

1.0

2.0

56.3

74.1

11.9

363.8

1.3

164.3

0.0

0.0

61.4

61.4

0.4

1.0

2.0

56.3

74.1

0.0

363.8

0.0

164.3

0.0

0.0

61.4

61.4

0.4

1.0

2.0

56.3

74.1

0.0

363.8

0.0

164.3

51.2

0.0

61.4

61.4

0.4

1.0

2.0

56.3

74.1

23.8

363.8

2.6

164.3

343.7

18.3

61.4

61.4

0.4

1.0

2.0

56.3

74.1

160.1

363.8

17.6

164.3

323.4

18.3

61.4

61.4

0.4

1.0

2.0

56.3

74.1

150.6

363.8

16.6

164.3

[Satisfactory]

__
Page 34 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Combined Footing, Based on ACI 318-08


DESIGN SUMMARY
CONCRETE STRENGTH

f c' =

ksi

REBAR YIELD STRESS


FOOTING WIDTH
FOOTING THICKNESS
DISTANCE BETWEEN COLUMNS

fy
W
D
L

60
90
48
30

ksi
in
in
ft

=
=
=
=

COMBINED FOOTING LONGITUDINAL REINFORCING


TOP
12
#
10
( d = 43.74 in )
( 1 Layer)
BOTTOM
13
#
10
( d = 43.74 in )
( 1 Layer)

COMBINED FOOTING HOOPS (ACI 21.5.3)


LOCATION
AT END
LENGTH
96
in

AT SPLICE
70
in
MAX{0.075fydb/[(fc')0.5(c+Ktr)/db], 12}
7 Legs # 5
@ 4 in o.c.

( 2h )
7 Legs # 5
@ 10 in o.c.

BAR
SPACING

MIN(d/4, 8db, 24dt, 12)

MIN(d/4, 4)

THE SEISMIC DESIGN IS ADEQUATE.


ANALYSIS
CHECK GB SECTION REQUIREMENTS (ACI 21.5.1)
Ln=L - c1 =

28.50

W /D=
W =

1.88
90

>

ft

>

0.3

>
<

in

4d=

14.58

[Satisfactory]
10
in
c1+1.5D =
90

ft

[Satisfactory]

[Satisfactory]
in
[Satisfactory]

CHECK SEISMIC FLEXURAL REQUIREMENTS


(ACI 21.5.2.1)

(ACI 21.5.2.2)

top =

0.004

bot =

0.004

>

Mn,top
where

>
<
>

min=MIN[3(fc')0.5/fy, 200/fy ]= 0.003


max =
0.025
[Satisfactory]
min =
0.003
[Satisfactory]

<

max =

(1/2)Mn,bot

0.025

[Satisfactory]

[Satisfactory]

[Satisfactory]

Mn,bot = bot bd2fy (1 - 0.588bot fy/fc') =

3433

ft-kips

Mn,top = top bd fy (1 - 0.588top fy/fc') =

3181

ft-kips

CHECK GB SHEAR STRENGTH (ACI 21.5.4)


Ve = (Mpr, top + Mpr,bot) / Ln =
where

286.5

kips

<

8(fc')0.5bd =

<

[2(fc')0.5bd + Avfyd/s ] =

Mpr,top = top bd fy (1.25 - 0.919top fy/fc') =

3929

ft-kips

Mpr,bot = bot bd2fy (1.25 - 0.919bot fy/fc') =


=
0.75
(ACI 9.3.2.3)
in2
Av =
2.17

4235

ft-kips

__
Page 35 of 533
524

1293.7

kips

[Satisfactory]

750.5

kips

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Two Pads with Grade Beam Design Based on ACI 318-08 & AISC 360-05
INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc' =

REBAR YIELD STRESS


SQUARE PAD SIZE

fy =
B =
T =

ksi

GRADE BEAM SIZE


Steel
Outside Concrete Width
Outside Concrete Depth
COLUMN DISTANCE

60
8
16
W18X65
W =
36
D =
36
L =
22

in
in
ft

GRADE BEAM EXTENSION

Le =

ft

FRAME AXIAL LOADS, ASD


GRAVITY AXIAL LOADS, ASD
SEISMIC LOADS, ASD
ALLOW SOIL PRESSURE
PAD REINFORCING

ksi
ft
in

PD,1 =

25

kips

PD,2 =

25

kips

PL,1 =

15

kips

PL,2 =

15

kips

(Live Load)

PE,1 =

-30

kips

PE,2 =

30

kips

(Seismic Load)

VE,1 =

50

kips

VE,2 =

30

kips

(Seismic Load)

ME,1 =

50

ft-kips

ME,2 =

50

ft-kips

(Seismic Load)

@ 12 o.c., Each Way, Bottom.

Qa =
8

2.5
#

(Dead Load)

ksf

THE GRADE BEAM DESIGN IS ADEQUATE.


ANALYSIS
CHECK OVERTURNING AT CENTER BOTTOM OF PAD 2 (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
MO =

ME,1 + ME,2 + (VE,1+VE,2)(D+T) - PE,1L

MR =

(PD,1 + conc B T) L + 0.5conc & steel(L + 2Le) L D W =

1106.7 ft-kips
1322.7

>

0.75 x 1.4 MO / (0.9) =

1291 ft-kips
[Satisfactory]

CHECK SOIL BEARING CAPACITY

M O P D,2 + P L,2 + ( Conc& Steel SOIL ) B T + WD ( 0.5L + L e )


+
=
2
2
BL
B
2

Q MAX =
where

conc =

0.15 kcf

soil =

0.11 kcf

1.57 ksf, (net pressure)

<

4/3 Qa

[Satisfactory]

CHECK PAD FLEXURAL REINFORCING

0.85 f c' 1 1

f
where

d=

Mu
0.383Bd 2 f c'

0.0020

12.25

<
provd =

0.0030

in

Qu,max = 1.5 Qmax =

2.36

ksf, factor 1.5 for SD

Mu = 0.125 (B-W) B Qu,max =

129

max =

0.0206

(ACI 10.2.7.3 & 10.3.5)

min =

0.0018

(ACI 7.12.2.1)

ft-kips

[Satisfactory]
(cont'd)

CHECK PAD ONE WAY SHEAR CAPACITY


Vn

<

Vu
where

Vu = 0.5 (B - W) B Qu,max - d B Qu,max =


Vn = 2 d B (fc')0.5 =
=
0.75

CHECK STEEL GB FLEXURAL CAPACITY


A
19.1

[Satisfactory]

Zx
133

Fy
50

(AISC 365-05 F1)


M allowable = Z x F y / b =

27.9

kips

__
111.6

kips

1.67

331.8

ft-kips

Page 36 of 533
524

(cont'd)

>

Max ( M top , M bot )

[Satisfactory]

(AISC 360-05 F1)

2
M top = M GB , wt + ( P D ,1 + P L ,1 + P E ,1 + Wt PAD ,1 Q MIN B ) L 0.5V E ,1D M E ,1 Q MIN (V E ,1 + V E ,2 ) / ( Q MAX + Q MIN ) ( 0.5D + T ) =

329

ft-kips

2
M bot = M GB , wt ( P D,2 + P L ,2 + P E ,2 + Wt PAD ,1 Q MAX B ) L 0.5V E ,2D M E ,2 Q MAX (V E ,1 + V E ,2 ) / ( Q MAX + Q MIN ) ( 0.5D + T ) =

168

ft-kips

M O P D ,2 + P L ,2 + Conc & Steel B T + WD ( 0.5L + Le )


+
=
2
2
BL
B
2

where

Q MAX =
QMIN =

0.36

ksf, (full ASD pressure)

__
Page 37 of 533
524

1.97

ksf, (full ASD pressure)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Two Pads with Grade Beam Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc' =

ksi

REBAR YIELD STRESS


SQUARE PAD SIZE

COLUMN DISTANCE

fy
B
T
W
D
L

60
8
16
36
36
22

ksi
ft
in
in
in
ft

GRADE BEAM EXTENSION

Le =

ft

GRADE BEAM SIZE

=
=
=
=
=
=

GRAVITY AXIAL LOADS, ASD


SEISMIC LOADS, ASD

PD,1 =

25

kips

PD,2 =

25

kips

(Dead Load)

PL,1 =

15

kips

PL,2 =

15

kips

(Live Load)

PE,1 =

-30

kips

PE,2 =

30

kips

(Seismic Load)

VE,1 =

50

kips

VE,2 =

30

kips

(Seismic Load)

ME,1 =

50

ft-kips

ME,2 =

50

ft-kips

(Seismic Load)

@ 12 o.c., Each Way, Bottom.

Qa =
8

ALLOW SOIL PRESSURE


PAD REINFORCING

2.5
#

ksf

GRADE BEAM LONGITUDINAL REINFORCING


TOP
7
#
7
( d = 31.94 in )
( 1 Layer)
BOTTOM
7
#
7
( d = 31.94 in )
( 1 Layer)
GRADE BEAM HOOPS (ACI 21.5.3)
LOCATION
AT END
LENGTH
72
in
BAR

SPACING

AT SPLICE
48
in

( 2h )
MAX{0.075fydb/[(fc')0.5(c+Ktr)/db], 12}
Legs # 5
4 Legs # 5
(Legs to alternate long bars supported, ACI 7.10.5.3)
@ 7 in o.c.
@ 4 in o.c.

MIN(d/4, 8db, 24dt, 12)

MIN(d/4, 4)

THE GRADE BEAM DESIGN IS ADEQUATE.


ANALYSIS
CHECK OVERTURNING AT CENTER BOTTOM OF PAD 2 (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
MO =
MR =

ME,1 + ME,2 + (VE,1+VE,2)(D+T) - PE,1L

(PD,1 + conc B T) L + 0.5conc(L + 2Le) L D W =

1106.7 ft-kips
1306.8

>

0.75 x 1.4 MO / (0.9) =

1291 ft-kips
[Satisfactory]

CHECK SOIL BEARING CAPACITY

M O + P D ,2 + P L ,2 + ( CONC SOIL ) B T + WD ( 0.5 L + L e ) =


2
2
BL
B
2

Q MAX =
where

conc =

0.15 kcf

soil =

0.11 kcf

1.55

ksf, (net pressure)

CHECK PAD FLEXURAL REINFORCING

0.85 f c' 1 1

f
where

d=

Mu
0.383Bd 2 f c'

__
0.0020

<

provd =

12.25

Qu,max = 1.5 Qmax =

in
2.33

Mu = 0.125 (B-W)2 B Qu,max =

0.0030

ksf, factor 1.5 for SD

max =

0.0155

(ACI 10.2.7.3 & 10.3.5)

min =

0.0018

(ACI 7.12.2.1)

128

ft-kips

[Satisfactory]

Page 38 of 533
524

<

4/3 Qa

[Satisfactory]

(cont'd)
CHECK PAD ONE WAY SHEAR CAPACITY
Vn

<

Vu
where

[Satisfactory]

Vu = 0.5 (B - W) B Qu,max - d B Qu,max =


Vn = 2 d B (fc')0.5 =
=
0.75

96.6

27.6

kips

kips

CHECK GB SECTION REQUIREMENTS (ACI 21.5.1)


Pu = 1.5(VE,1 - VE,2) =
Ln=L - B =

14.00

W /D=

1.00

W =

36

30

<

0.1Agfc' =

4d=

10.65

kips

>

ft

>

0.3

388.8
ft

kips

[Satisfactory]

[Satisfactory]

[Satisfactory]

>
<

B+1.5D =

top =

0.004

>

min=MIN[3(fc')0.5/fy, 200/fy ]=

<

max =

0.025

[Satisfactory]

bot =

0.004

>

min =

0.003

[Satisfactory]

<

max =

0.025

[Satisfactory]

Mn,top

>

(1/2)Mn,bot

in

10

in

[Satisfactory]
150

in

[Satisfactory]

CHECK GB FLEXURAL REQUIREMENTS

(ACI 21.3.5.1)

(ACI 21.5.2.2)

where

0.003

[Satisfactory]

[Satisfactory]

Mn,bot = bot bd2fy (1 - 0.588bot fy/fc') =

642

ft-kips

>

Mu,bot / [Satisfactory]

Mn,top = top bd fy (1 - 0.588top fy/fc') =


=
0.9

642

ft-kips

>

Mu,top / [Satisfactory]

2
M u ,top = 1.5 M GB, wt + ( P D,1 + P L,1 + P E ,1 + Wt PAD ,1 Q MIN B ) L 0.5V E ,1D M E ,1 Q MIN (V E ,1 + V E ,2 ) / ( Q MAX + Q MIN ) ( 0.5D + T ) =
2
M u ,bot = 1.5 M GB, wt ( P D,2 + P L,2 + P E ,2 + Wt PAD,1 Q MAX B ) L 0.5V E ,2D M E ,2 Q MAX (V E ,1 + V E ,2 ) / ( Q MAX + Q MIN ) ( 0.5D + T ) =

M O P D ,2 + P L ,2 + CONC B T + WD ( 0.5L + L e )
+
=
2
2
BL
B

453

ft-kips

217

ft-kips

where

Q MAX =
QMIN =

0.38

1.95

ksf, (full ASD pressure)

377.8

kips

[Satisfactory]

349.0

kips

ksf, (full ASD pressure)

Factor 1.5 is for SD


CHECK GB SHEAR STRENGTH (ACI 21.5.4)
Ve = (Mpr, top + Mpr,bot) / Ln =

where

113.3

kips

<

8(fc')0.5bd =

<

[2(fc') bd + Avfyd/s ] =
0.5

Mpr,top = top bd2fy (1.25 - 0.919top fy/fc') =

793

ft-kips

Mpr,bot = bot bd2fy (1.25 - 0.919bot fy/fc') =


=
0.75
(ACI 9.3.2.3)

793

ft-kips

Av =

1.24

in2

__
Page 39 of 533
524

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Retaining Wall Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH
fc'
REBAR YIELD STRESS
fy
LATERAL SOIL PRESSURE Pa=ka b
BACKFILL SPECIFIC WEIGHT
b
SATURATED SPECIFIC WEIGHT
sat
WATER TABLE DEPTH
h
PASSIVE PRESSURE
Pp
SURCHARGE WEIGHT
ws
WALL TOP LIVE LOAD
WL
FRICTION COEFFICIENT

Qa
ALLOW SOIL PRESSURE
tt
THICKNESS OF TOP STEM
tb
THICKNESS OF KEY & STEM
LT
TOE WIDTH
LH
HEEL WIDTH
HT
HEIGHT OF TOP STEM
HB
HEIGHT OF BOT. STEM
hf
FOOTING THICKNESS
hk
KEY DEPTH
hp
SOIL OVER TOE

=
4
ksi
=
60
ksi
=
30
pcf (equivalent fluid pressure)
=
110
pcf
=
118
pcf
=
24.5 ft
=
300
psf / ft
=
220
psf
=
4000 lbs / ft
=
0.4
=
4
ksf
=
18
in
=
18
in
=
3
ft
=
8
ft
=
10
ft
=
10
ft
=
18
in
=
36
in
=
0
in
TOP STEM VERT. REINF. (As,1)
#
9
@
6
in o.c.
As,1 LOCATION (0=at soil face, 1=at middle, 2=at each face)
0
at soil face
TOP STEM HORIZ. REINF. (ACI 14.1.2)
#
6
@ 9 in o.c., at soil face
#
9
@
6
in o.c.
BOT. STEM VERT. REINF. (As,2)
0
at soil face
As,2 LOCATION (0=at soil face, 1=at middle, 2=at each face)
BOT. STEM HORIZ. REINF. (ACI 14.1.2)
#
6
@ 9 in o.c., at soil face
#
7
@
7
in o.c.
TOP REINF.OF FOOTING (As,3)
#
7
@
12
in
[THE WALL DESIGN IS ADEQUATE.]
BOT. REINF.OF FOOTING (As,4)

ANALYSIS
SERVICE LOADS
Hb = 0.5 Pa h2 + h Pa H + 0.5 [Pa (sat - w) / b +w] H2

=
Where
h = 21.5 ft ,
Hs = ws Pa (HT + HB + hf) / b
Hp = 0.5 Pp (hp + hf + hk)2
Ws = ws (LH + tb - tt)
Wb = Wb1 + Wb2
Where Wb1 = 17.6 kips ,
Wf = hf (LH + tb + LT) c
Wk = hk tb c
Ww,t = tt HT c
Ww,b = tb HB c
WL =
FACTORED LOADS
Hb = 1.6 Hb
Hs = 1.6 Hs
Ws = 1.6 Ws
Wb = 1.2 Wb
Wf = 1.2 Wf
Wk = 1.2 Wk
Ww,t = 1.2 Ww,t
Ww,b = 1.2 Ww,b
WL = 1.6 WL

=
=
=
=
=
=
=
=
=

6.93
0
1.29
3.04
1.76
17.60
= 0.00
2.81
0.68
2.25
2.25
4.00

H=

=
=
=
=
Wb2

=
=
=
=
=

11.09 kips
2.06 kips
2.82 kips

kips
ft
kips
kips
kips
kips
kips
kips
kips
kips
kips
kips

OVERTURNING MOMENT

21.12 kips
3.38
0.81
2.70
2.70
6.40

kips
kips
kips
kips
kips

Hb
Hs

Hy

H y

6.93
1.29
8.22

11.09
2.06
13.16

7.17
10.75

49.69
13.87
63.56

79.51
22.19
101.70

(cont'd)
RESISTING MOMENT
W

Wx

Ws
Wb
Wf
Wk
Ww,t
Ww,b

2.82
1.76
8.50
14.96
17.60
21.12
8.50
149.60
2.81
3.38
6.25
17.58
0.68
0.81
3.75
2.53
2.25
2.70
3.75
8.44
2.25
3.75
8.44
2.70
27.35
201.54
33.52
CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)

L = LT + t b + L H

( W + W L )
q MAX =

12.50

1+

6e
L

W x
23.94
179.52
21.09
3.04
10.13
10.13
247.84

MHP =

0.17

OVERTURNING FACTOR OF SAFETY (1806.1)

SF =

Wx + MHP
=
Hy

L Wx Hy MHP
e=
2
W

ft

, for e

BL
2 ( W + W L )
L
, for e >
3B(0.5 L e)
6

L
6 =

3.96

ft-kips/ft

ksf

<

3.174
>
1.5
[Satisfactory]

1.21

ft

[Satisfactory]

Qa

CHECK FLEXURE CAPACITY, AS,1 & AS,2, FOR STEM (ACI 318-08 SEC.15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, & 12.5)
h=
20
ft ,
A = ws Pa / b =
B = h Pa =

H' =
0
60
plf
600 plf

C = [Pa (sat - w) / b + w] H' =0


At base of top stem
Mu =
12.80
Vu =
3.36
Pu =
2.70

ft

plf

ft-kips
kips
kips

At base of bottom stem


Mu =
83.20 ft-kips
Vu =
11.52 kips
Pu =
5.40 kips
At top stem

M n = AS f

AS f y P u
1.7bf c'

where

0.85 1 f c
'

MAX =

f y

d
b

As

u
u +t

MIN = 0.0018

t
d

=
=
=
=
=
=

At base of bottom stem

125.99 ft-kips ,
>
Mu
[Satisfactory]
15.44 in ,
12
in ,
0.9
(ACI 318 Fig R9.3.2)
2
in ,
2
0.011
0.021
>
0.002
<

126.28

15.44
12
0.9
2
0.011

ft-kips
>
Mu
[Satisfactory]
in
in
(ACI 318 Fig R9.3.2)
in2

0.021

[Satisfactory]

>

[Satisfactory]
0.002

[Satisfactory]

<

[Satisfactory]

CHECK SHEAR CAPACITY FOR STEM (ACI 318-08 SEC.15.5.2, 11.1.3.1, & 11.2)

V n = 2 bd

'
c

At top stem
17.57 kips ,
>

Vu
[Satisfactory]

where = 0.75 (ACI 318-08, Section 9.3.2.3 )

At base of bottom stem


17.57 kips
>

Vu

[Satisfactory]

(cont'd)
CHECK HEEL FLEXURE CAPACITY, AS,3, FOR FOOTING (ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

0.85 1 f c
'

MAX =

f y

u
u +t

MIN =

0.021

( q u ,3 + 2q u, heel ) b L 2H ,
LH
LH
w s + wb +
wf
2
6
L

M u ,3 =

q u ,3b S 2
LH
LH
,
ws + wb +
wf
L
2
6

0.85 f 'c 1 1

f
where

d
eu
S

( A S, 3 ) required

M u ,3
0.383b d 2 f 'c

for eu >

0.005

qu, toe
qu, heel
qu, 3

=
=
=

for eu

0.0018 h f
2
d

0.001

L
6

= 58.12 ft-kips

L
6

=
=
=

15.56 in
1.99 ft
n/a
in2 / ft

0.86

<

A S, 3

6.24
0.15
4.04

ksf
ksf
ksf

[Satisfactory]

CHECK TOE FLEXURE CAPACITY, AS,4, FOR FOOTING (ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

MAX =

M u ,4

(q

u ,4

0.85 1 f c'
f y

+ 2q u ,toe ) b LT2
6

u
u +t

0.021

MIN = MIN

4
0.0018 h f
,
d
3
2

LT w f
2L

24.67

ft-kips
where

0.85 f 'c 1 1

=
( A S, 4 ) required

f
=

M u ,4
0.383b d 2 f 'c

0.002

0.38

in2 / ft

<

A S, 4

[Satisfactory]

CHECK SLIDING CAPACITY (IBC 09 1807.2.3)


1.5 (Hb + Hs ) =

12.3 kips

Hp + W =
<
[Satisfactory]

13.98

kips

d
qu, 4

=
=

14.56 in
4.78 ksf

0.001

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Retaining Wall Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH
REBAR YIELD STRESS
LATERAL SOIL PRESSURE
PASSIVE PRESSURE

fc'
fy
Pa
Pp
b
ws

Qa
tt
tb
LT
LH
HT
HB
hf
hk
hp

=
4
ksi
=
60
ksi
=
30
pcf (equivalent fluid pressure)
=
300
psf / ft
BACKFILL SPECIFIC WEIGHT
=
110
pcf
=
220
psf
SURCHARGE WEIGHT
FRICTION COEFFICIENT
=
0.4
ALLOW SOIL PRESSURE
=
4
ksf
=
18
in
THICKNESS OF TOP STEM
THICKNESS OF KEY & STEM
=
18
in
=
3
ft
TOE WIDTH
HEEL WIDTH
=
8
ft
HEIGHT OF TOP STEM
=
10
ft
=
10
ft
HEIGHT OF BOT. STEM
=
18
in
FOOTING THICKNESS
=
36
in
KEY DEPTH
SOIL OVER TOE
=
0
in
#
9
@
6
in o.c., at soil face
TOP STEM VERT. REINF. (As,1)
0
at soil face
As,1 LOCATION (0=at soil face, 1=at middle, 2=at each face)
TOP STEM HORIZ. REINF. (ACI 14.1.2)
#
6
@ 9 in o.c., at soil face
#
9
@
6
in o.c., at soil face
BOT. STEM VERT. REINF. (As,2)
As,2 LOCATION (0=at soil face, 1=at middle, 2=at each face)
0
at soil face
BOT. STEM HORIZ. REINF. (ACI 14.1.2)
#
6
@ 9 in o.c., at soil face
#
7
@
6
in
TOP REINF.OF FOOTING (As,3)
BOT. REINF.OF FOOTING (As,4)
#
7
@
12
in
[THE WALL DESIGN IS ADEQUATE.]

ANALYSIS
SERVICE LOADS
Hb = 0.5 Pa (HT + HB + hf)2
Hs = ws Pa (HT + HB + hf) / b
Hp = 0.5 Pp (hp + hf + hk)2
Ws = ws (LH + tb - tt)
Wb = [HT (LH + tb - tt) + HB LH] b
Wf = hf (LH + tb + LT) c
Wk = hk tb c
Ww,t = tt HT c
Ww,b = tb HB c
FACTORED LOADS
Hb = 1.6 Hb
Hs = 1.6 Hs
Ws = 1.6 Ws
Wb = 1.2 Wb
Wf = 1.2 Wf
Wk = 1.2 Wk
Ww,t = 1.2 Ww,t
Ww,b = 1.2 Ww,b

=
=
=
=
=
=
=
=

=
=
=
=
=
=
=
=
=

6.93
1.29
3.04
1.76
17.60
2.81
0.68
2.25
2.25

11.09 kips
2.06 kips
2.82 kips

kips
kips
kips
kips
kips
kips
kips
kips
kips

OVERTURNING MOMENT

21.12 kips
3.38
0.81
2.70
2.70

Hb
Hs

kips
kips
kips
kips

Hy

H y

6.93
1.29
8.22

11.09
2.06
13.16

7.17
10.75

49.69
13.87
63.56

79.51
22.19
101.70

RESISTING MOMENT
Ws
Wb
Wf
Wk
Ww,t
Ww,b

1.76
17.60
2.81
0.68
2.25
2.25
27.35

2.82
21.12
3.38
0.81
2.70
2.70
33.52

Wx

W x

8.50
8.50
6.25
3.75
3.75
3.75

14.96
149.60
17.58
2.53
8.44
8.44
201.54

23.94
179.52
21.09
3.04
10.13
10.13
247.84

__
Page 43 of 533
524

MHP =

0.17

ft-kips/ft

OVERTURNING FACTOR OF SAFETY (1806.1)

SF =

Wx + MHP
=
Hy

3.174
> 1.5
[Satisfactory]

(cont'd)
CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)

L = LT + t b + L H

W 1 +

q MAX

12.50

6e
L

L Wx Hy MHP
e=
2
W

ft

L
=
6
BL
L
2W
, for e >
3B (0.5 L e)
6
, for e

3.46

ksf

<

Qa

1.21

ft

[Satisfactory]

CHECK FLEXURE CAPACITY, AS,1 & AS,2, FOR STEM (ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)
3

P a y + Pa y w s
6
2 b

Mu =

Pu = W w

M n = AS f

AS f y P u
1.7bf 'c
where

MAX =

At top stem
12.80 ft-kips ,

0.85 1 f c'
f y

MIN = 0.0018

d
b

As

u
u +t

=
=
=
=
=
=

t
d

2.70

At base of bottom stem


83.20 ft-kips

kips ,

5.40

125.99 ft-kips ,
>
Mu
[Satisfactory]
15.44 in ,
12
in ,
0.9
(ACI 318 Fig R9.3.2)
in2 ,
2

126.28

15.44
12
0.9
2
0.011

0.011
0.021
>
0.002
<

kips

ft-kips
>
Mu
[Satisfactory]
in
in
(ACI 318 Fig R9.3.2)
in2

0.021

[Satisfactory]

>

[Satisfactory]
0.002

[Satisfactory]

<

[Satisfactory]

CHECK SHEAR CAPACITY FOR STEM (ACI 318-08 SEC.15.5.2, 11.1.3.1, & 11.2)
2

y
w y
V = Pa + sP a
2
b

V n = 2 bd

'
c

At top stem
3.36 kips ,

17.57

At base of bottom stem


11.52 kips

kips ,

17.57

Vu

>

kips
>

[Satisfactory]

Vu

[Satisfactory]

where = 0.75 (ACI 318-08, Section 9.3.2.3 )


CHECK HEEL FLEXURE CAPACITY, AS,3, FOR FOOTING (ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

MAX =

M u ,3 =

'
0.85 1 f c
u
f y
u +t

MIN =

0.021

( q u ,3 + 2q u, heel ) b L 2H ,
LH
LH
w s + wb +
wf
2
6
L

for eu

__

q u ,3b S 2
LH
LH
,
ws + wb +
wf
2
6
L

L
for eu >
6

Page 44 of 533
524

0.0018 h f
2
d
L
6

= 63.30 ft-kips

0.001

(cont'd)

0.85 f

'
c

1 1

f
where

d
eu
S

( A S, 3 ) required

M u ,3
0.383b d 2 f

'
c

0.005

qu, toe
qu, heel
qu, 3

=
=
=

=
=
=

15.56 in
1.89 ft
n/a
2

in / ft

0.94

<

A S, 3

5.11
0.25
3.36

ksf
ksf
ksf

[Satisfactory]

CHECK TOE FLEXURE CAPACITY, AS,4, FOR FOOTING (ACI 318-08 SEC.15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, & 12.5)

MAX =

M u ,4

(q

u ,4

0.85 1 f c'
f y

+ 2q u ,toe ) b LT2
6

u +t

0.021

MIN = MIN

4
0.0018 h f
,
d
3
2

LT w f
2L

20.04

ft-kips
where

0.85 f 'c 1 1

=
( A S, 4 ) required

f
=

M u ,4
0.383b d 2 f 'c

0.002

in2 / ft

0.31

<

A S, 4

[Satisfactory]

CHECK SLIDING CAPACITY (IBC 09 1807.2.3)


1.5 (Hb + Hs ) =

12.3 kips

Hp + W =
<
[Satisfactory]

13.98

kips

__
Page 45 of 533
524

d
qu, 4

=
=

14.56 in
3.94 ksf

0.001

!"#"#$

!%%

&"$# '!& ( )#

'

+!, -

!
"
"
3

"

49

$%

&

'()*+#,
(-. ,
*/&0( *0(1

&

$%!

&

2.

$5

&

2 . '65!7 8 81

66!

&

%!

&

4
9

"

99

! %
<#

"
4

94

..

6$

.:

88

.
.
.

>

86

>

>&
3

9 '

'6 #. C //,
(?8

?6

9 '

9 '

6$681

9 '

9 99

'

!%
;

'

#
#

!%

&

'

F
F

#. B, # (1

?$1

A 68 - B ? #. B, # (

A 5 - B ? #. B, # (
A

8$

F > 18

$8%

&

F> 1 2 :

!85

&

$ E

&

$%$

&

! 5

&

67 !

&

%86

&

> .:

! !

&

;?.

..

6!%

&

;?:

.:

6 %

&

H ' F .: G..1 F
> ' F .: F 1

;?.
;?:

&

!$%

&

78

&

6
:

56

-B

#. B, # (

!% ' F
F > 18
; ' F .: G..1
:

-B

'>& F > F > 18

&

68

#. B, # (

A
!

6$681

?1

'

A
8

9 99

#. B, # (1

?81

'6 #. C //,
(?8

?8

?61

6!E

&

8668

&

68

8%

&

$%$

78

68

!78

&

!85

!$%

68
6E5

&
&

E!7

6$%8

68

68
68

;?.
;?:

$8%

56

68!

$%5

6E%!

E67

$6%E

%%

6E

!E

55

6!!5$

"
!

!! ""
""
!

$%

"

$%

"

"

#$

"

"!

!"
!

"

"

!!

#&'

()&

"

&

&

" # '

((

#&'

()&
#

./

%!
#

"

%-

, .

./

"

"

$0.1.

"

"

%
"
#

#&'
%

23 4"

"

&

" !

#&'

()&

%
#

%./

! #&'

%(.

"

234"

&

, .

$0.1.

#&'

"

./

#&'

()&

%!

%-

"!

$0.1.

# (%

56%
.6

"

56%0..7

"
!

56%
# (%

1.56 1.

"

#&'

!
()&

%!

%-

$0.1.

!
56%

# (%

# (%

1.56 1.

&8&
9

!#
9
!

"

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Retaining / Fence Wall Design Based on TMS 402-08 & ACI 318-08
INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
1
Yes
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
1
CMU
=
1.5
ksi
MASONRY STRENGTH
fm'
=
4.5
ksi
CONCRETE STRENGTH
fc'
REBAR YIELD STRESS
fy
=
60
ksi
=
30
pcf (equivalent fluid pressure)
LATERAL SOIL PRESSURE
Pa
=
400
psf / ft
PASSIVE PRESSURE
Pp
BACKFILL SPECIFIC WEIGHT
b
=
110
pcf
=
100
psf
SURCHARGE WEIGHT
ws
WALL TOP LIVE LOAD
WL
=
5000 lbs / ft
=
20
psf
SERVICE LATERAL FORCE
wLat
FRICTION COEFFICIENT

=
0.3
Qa
=
3
ksf
ALLOW SOIL PRESSURE
tt
THICKNESS OF TOP STEM
=
8
in
tb
=
12
in
THICKNESS OF KEY & STEM
LT
TOE WIDTH
=
3
ft
LH
=
6
ft
HEEL WIDTH
HF
=
4
ft
HEIGHT OF FENCE STEM
HT
HEIGHT OF TOP STEM
=
4
ft
HB
=
4
ft
HEIGHT OF BOT. STEM
hf
FOOTING THICKNESS
=
12
in
hk
=
12
in
[THE WALL DESIGN IS ADEQUATE.]
KEY DEPTH
hp
SOIL OVER TOE
=
12
in
#
7
@
16
in o.c.
TOP STEM REINF. (As,1)
0
at soil face
As,1 LOCATION (0=at soil face, 1=at middle, 2=at each face)
#
7
@
16
in o.c.
BOT. STEM REINF. (As,2)
0
at soil face
As,2 LOCATION (0=at soil face, 1=at middle, 2=at each face)
GROUTED CORES (0=fully, 1=at vertical rebars only)
0
solid
#
6
@
18
in o.c.
TOP REINF.OF FOOTING (As,3)
BOT. REINF.OF FOOTING (As,4)
#
5
@
14
in o.c.

ANALYSIS
SERVICE LOADS
Hb = 0.5 Pa (HT + HB + hf)2
Hs = ws Pa (HT + HB + hf) / b
Hp = 0.5 Pp (hp + hf + hk)2
HLat = wLat (HF + HT + HB - hp)
Ws = ws (LH + tb - tt)
Wb = [HT (LH + tb - tt) + HB LH] b
Wf = hf (LH + tb + LT) c
W k = hk t b c
Ww,t = tt (HT +HF) m
Ww,b = tb HB m
WL =
FACTORED LOADS
Hb = 1.6 Hb
Hs = 1.6 Hs
HLat = 1.6 HLat
Ws = 1.6 Ws
Wb = 1.2 Wb
Wf = 1.2 Wf
Wk = 1.2 Wk
Ww,t = 1.2 Ww,t
Ww,b = 1.2 Ww,b
WL = 1.6 WL

=
=
=
=
=
=
=
=
=
=

1.94
0.39
0.35
1.01

=
=
=
=
=
=
=
=
=
=
=

kips
kips
kips
kips

1.22
0.25
1.80
0.22
0.63
5.43
1.50
0.15
0.59
0.44
5.00

kips
kips
kips
kips
kips
kips
kips
kips
kips
kips
kips

OVERTURNING MOMENT

6.51 kips
1.80
0.18
0.70
0.53
8.00

kips
kips
kips
kips
kips

Hb
Hs
HLat

Hy

H y

1.22
0.25
0.22
1.68

1.94
0.39
0.35
2.69

3.00
4.50
7.50

3.65
1.10
1.65
6.40

5.83
1.77
2.64
10.24

(cont'd)
RESISTING MOMENT
Ws
Wb
Wf
Wk
Ww,t
Ww,b

Wx

W x

MHP =

0.63
5.43
1.50
0.15
0.59
0.44
8.74

1.01
6.51
1.80
0.18
0.70
0.53
10.74

6.83
6.91
5.00
3.50
3.33
3.50

4.33
37.52
7.50
0.53
1.95
1.54
53.37

6.92
45.03
9.00
0.63
2.35
1.85
65.77

OVERTURNING FACTOR OF SAFETY

0.53

ft-kips/ft

SF =

Wx + M HP
=
y
( H b + H s y + H Lat y )

SF =

Wx + M HP
=
( H by + H sy )

11.35

8.423

>

>
1.5
[Satisfactory]

CHECK SOIL BEARING CAPACITY (ACI 318 15.2.2)

L = LT + t b + L H

( W + W L )
q MAX =

10.00

1+

6e
L

L Wx Hy MHP
e=
2
W

ft

, for e

BL
2 ( W + W L )
L
, for e >
3B(0.5L e)
6

L
6 =

1.11

ksf

<

Qa

-0.32

ft

[Satisfactory]

CHECK FLEXURE CAPACITY FOR MASONRY STEM (TMS 402 2.3.3)


3

y
y ws
M = Pa + Pa
+ M Lat
6
2 b

P =W w

M allowable = MIN
where

0.59

te
d
bw
Fb
Fs
As

M allowable

=
=
=
=
=
=
=
=
=
=
=

At top stem
7.63 in ,
5.44 in ,
12 in ,
0.495 ksi ,
24 ksi ,
2
0.45 in ,

1.03

, AsF s d

kips

kd
kd
t
+P e
3
2 3

At base of bottom stem


<== Based on effective section area.
11.63 in
<== Based on TMS 402-08, 1.13.3.5
9.44 in
12
0.495
24
0.45
0.004
1350

0.007
,
1350 ksi ,
29000 ksi ,
21.48
0.42

=
>

At base of bottom stem


4.86
ft-kips

kips ,

kd
1
t
P d e
b wkd F b d
2
3
2

Em
Es
n
k
and

At top stem
1.18 ft-kips ,

29000

in
ksi
ksi
in2
ksi
ksi

21.48
0.34

2.54 ft-kips ,

6.28

M
[Satisfactory]

>

ft-kips
M
[Satisfactory]

CHECK SHEAR CAPACITY FOR MASONRY STEM (TMS 402 2.3.5)


2

y
w y
V = P a + s P a + V Lat
2
b
V allow able = d bwMIN

'
m

, 50

At top stem
0.51 kips ,

2.53
>

kips ,
V
[Satisfactory]

At base of bottom stem


1.40
kips

4.39

kips
>

V
[Satisfactory]

1.1

(cont'd)
CHECK HEEL FLEXURE CAPACITY, AS,3, FOR FOOTING (ACI 318 15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

0.85 1 f c
'

MAX =

M u ,3 =

f y

u
u +t

MIN =

0.023

( q u ,3 + 2q u, heel ) b L 2H ,
LH
LH
w s + wb +
wf
2
6
L
q u ,3b S 2
LH
LH
,
ws + wb +
wf
2
6
L

0.85 f

'
c

M u ,3
0.383b d 2 f

1 1

f
where

d
eu
S

( A S, 3 ) required

for eu >

for eu

0.0018 h f
2
d

L
6

L
6

0.001

0.90 ft-kips

'
c

0.000

qu, toe
qu, heel
qu, 3

=
=
=

=
=
=

9.63 in
0.61 ft
n/a
in2 / ft

0.13

<

A S, 3

2.56
1.18
1.78

ksf
ksf
ksf

[Satisfactory]

CHECK TOE FLEXURE CAPACITY, AS,4, FOR FOOTING (ACI 318 15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

MAX =

M u ,4

(q

u ,4

0.85 1 f c'
fy

u +t

+ 2q u ,toe ) b LT2
6

MIN = MIN

0.023

LT w f
2L

9.85

ft-kips
where

0.85 f c 1 1
'

=
( A S, 4 ) required

f
=

4
0.0018 h f
,
3
2
d

M u ,4
'
0.383b d 2 f c

d
qu, 4

=
=

8.69 in
1.98 ksf

0.002

0.26

in2 / ft

<

A S, 4

[Satisfactory]

CHECK SLIDING CAPACITY (IBC 09 1807.2.3)


1.1 (Hb + Hs + HLat) =

1.85 kips

<

Hp + W =

4.42

kips

[Satisfactory]

1.5 (Hb + Hs) =

2.19 kips

<

Hp + W =

4.42

kips

[Satisfactory]

0.001

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Retaining Wall Design, for Masonry Top & Concrete Bottom, Based on TMS 402-08 & ACI 318-08

INPUT DATA & DESIGN SUMMARY


SPECIAL INSPECTION ( 0=NO, 1=YES )
1
Yes
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
1
CMU
=
1.5
ksi
MASONRY STRENGTH
fm'
=
4.5
ksi
CONCRETE STRENGTH
fc'
REBAR YIELD STRESS
fy
=
60
ksi
=
30
pcf (equivalent fluid pressure)
LATERAL SOIL PRESSURE
Pa
=
400
psf / ft
PASSIVE PRESSURE
Pp
BACKFILL SPECIFIC WEIGHT
b
=
110
pcf
=
100
psf
SURCHARGE WEIGHT
ws
WALL TOP LIVE LOAD
WL
=
4000 lbs / ft
=
20
psf
SERVICE LATERAL FORCE
wLat
FRICTION COEFFICIENT

=
0.3
Qa
=
3
ksf
ALLOW SOIL PRESSURE
tt
THICKNESS OF TOP STEM
=
8
in
tb
=
10
in
THICKNESS OF KEY & STEM
LT
TOE WIDTH
=
3
ft
LH
=
6
ft
HEEL WIDTH
HF
=
4
ft
HEIGHT OF FENCE STEM
HT
HEIGHT OF TOP STEM
=
4
ft
HB
=
6
ft
HEIGHT OF BOT. STEM
hf
FOOTING THICKNESS
=
12
in
hk
=
12
in
[THE WALL DESIGN IS ADEQUATE.]
KEY DEPTH
hp
SOIL OVER TOE
=
12
in
#
7
@
16
in o.c.
TOP STEM REINF. (As,1)
0
at soil face
As,1 LOCATION (0=at soil face, 1=at middle, 2=at each face)
MASONRY GROUTED CORES (0=fully, 1=at vertical rebars only)

solid

#
7
@
BOT. STEM REINF. (As,2)
As,2 LOCATION (0=at soil face, 1=at middle, 2=at each face)
TOP REINF.OF FOOTING (As,3)
#
6
@
#
5
@
BOT. REINF.OF FOOTING (As,4)

16
0
18
14

in o.c.
at soil face
in o.c.
in o.c.

ANALYSIS
SERVICE LOADS
Hb = 0.5 Pa (HT + HB + hf)2
Hs = ws Pa (HT + HB + hf) / b
Hp = 0.5 Pp (hp + hf + hk)2
HLat = wLat (HF + HT + HB - hp)
Ws = ws (LH + tb - tt)
Wb = [HT (LH + tb - tt) + HB LH] b
Wf = hf (LH + tb + LT) c
W k = hk t b c
Ww,t = tt (HT +HF) m
Ww,b = tb HB c
WL =
FACTORED LOADS
Hb = 1.6 Hb
Hs = 1.6 Hs
HLat = 1.6 HLat
Ws = 1.6 Ws
Wb = 1.2 Wb
Wf = 1.2 Wf
Wk = 1.2 Wk
Ww,t = 1.2 Ww,t
Ww,b = 1.2 Ww,b
WL = 1.6 WL

=
=
=
=
=
=
=
=
=
=

2.90
0.48
0.42
0.99

=
=
=
=
=
=
=
=
=
=
=

kips
kips
kips
kips

1.82
0.30
1.80
0.26
0.62
6.67
1.48
0.13
0.59
0.00
4.00

kips
kips
kips
kips
kips
kips
kips
kips
kips
kips
kips

OVERTURNING MOMENT

8.01 kips
1.77
0.15
0.70
0.00
6.40

kips
kips
kips
kips
kips

Hb
Hs
HLat

Hy

H y

1.82
0.30
0.26
2.38

2.90
0.48
0.42
3.80

3.67
5.50
8.50

6.66
1.65
2.21
10.52

10.65
2.64
3.54
16.82

(cont'd)
RESISTING MOMENT
Ws
Wb
Wf
Wk
Ww,t
Ww,b

Wx

W x

MHP =

0.62
6.67
1.48
0.13
0.59
0.00
9.48

0.99
8.01
1.77
0.15
0.70
0.00
11.62

6.75
6.80
4.92
3.42
3.33
3.42

4.16
45.38
7.25
0.43
1.95
0.00
59.17

6.66
54.45
8.70
0.51
2.35
0.00
72.67

OVERTURNING FACTOR OF SAFETY

SF =

SF =

0.53

ft-kips/ft

Wx + M HP

( H b y + H s y + H Lat y )
Wx + M HP

( H by + H sy )

= 5.678

7.189

>

1.1

>
1.5
[Satisfactory]

CHECK SOIL BEARING CAPACITY (ACI 318 15.2.2)

L = LT + t b + L H

( W + W L )
q MAX

9.83

1+

L Wx Hy MHP
e=
2
W

ft

1.24

ksf

<

CHECK FLEXURE CAPACITY FOR MASONRY TOP STEM (TMS 402-08 2.3.3)
3

-0.16

ft

6e
L

L
, for e
BL
6 =
2 ( W + W L )
L
, for e >
3B (0.5L e)
6

[Satisfactory]

Qa

y
y ws
M = Pa + Pa
+ M Lat
6
2 b

1.18

1
kd
t
P d e
b wkd F b d
2
3
2

M allowable = MIN
where

=
=
=
=
=
=

te
d
bw
Fb
Fs
As

7.63
5.44
12
0.495
24
0.45

P =W w

ft-kips ,

0.59 kips

kd
t kd
+P e
3
2 3

, As F s d

<== Based on effective section area.


<== Based on TMS 402-08, 1.13.3.5

in ,
in ,
in ,
ksi ,
ksi ,
in2 ,

=
=
=
=

Em
Es
n

0.007
1350
29000

2.54

>
M
[Satisfactory]

ksi
ksi

21.48

0.42

CHECK FLEXURE CAPACITY FOR CONCRETE BOTTOM STEM (ACI 318-08 SEC.15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, & 12.5)

Mu =

P a y + P a y ws +
M Lat
6
2 b

M n = AS f

where

d
b

=
=
=

0.85 1 f c
'

MAX =

AS f y P u
'
1.7bf c

f y

MIN = 0.0018

13.30 ft-kips

14.73 ft-kips

7.56
12
0.9

u
=
u +t

t
=
d

0.002

0.023

<

Pu = W w

>

in ,
As
in ,

(ACI 318 Fig R9.3.2)


>

Mu

=
=

0.70 kips

[Satisfactory]

0.45
0.005

in2

[Satisfactory]

[Satisfactory]

CHECK SHEAR CAPACITY FOR MASONRY TOP STEM (TMS 402-08 2.3.5)
2

y
w y
V = P a + s P a + V Lat
2
b
V allow able = d bwMIN

'
m

, 50

0.51

kips ,

2.53

kips

>

ft-kips

[Satisfactory]

(cont'd)
CHECK SHEAR CAPACITY FOR CONCRETE BOTTOM STEM (ACI 318-08 SEC.15.5.2, 11.1.3.1, & 11.2)
2

P a y + ws P a y +
V Lat
2
b

Vu =

V n = 2 bd

'
c

3.25

kips ,

9.13

kips

Vu

>

[Satisfactory]

where = 0.75 (ACI 318-08, Section 9.3.2.3 )


CHECK HEEL FLEXURE CAPACITY, AS,3, FOR FOOTING (ACI 318 15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

0.85 1 f c
'

MAX =

M u ,3 =

f y

u
u +t

MIN =

0.023

( q u ,3 + 2q u, heel ) b L 2H ,
LH +
LH
ws
wb +
wf
2
6
L
2

q u ,3b S
LH
LH
,
ws + wb +
wf
2
6
L

0.85 f

'
c

1 1

f
where

d
eu
S

( A S, 3 ) required

M u ,3
0.383b d 2 f

for eu

0.0018 h f
2
d

L
6

0.001

6.04 ft-kips

L
for eu >
6

'
c

0.001

qu, toe
qu, heel
qu, 3

=
=
=

=
=
=

9.63 in
0.63 ft
n/a
in2 / ft

0.14

<

A S, 3

2.54
1.12
1.78

ksf
ksf
ksf

[Satisfactory]

CHECK TOE FLEXURE CAPACITY, AS,4, FOR FOOTING (ACI 318 15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

MAX =

M u ,4

(q
=

u ,4

0.85 1 f c'
fy

u +t

+ 2q u ,toe ) b LT2
6

MIN = MIN

0.023

LT w f
2L

9.73

ft-kips
where

0.85 f

'
c

=
( A S, 4 ) required

M u ,4
1 1
'
0.383b d 2 f c
f
=

4
0.0018 h f
,
3
2
d

d
qu, 4

=
=

8.69 in
1.95 ksf

0.002

0.25

in2 / ft

CHECK SLIDING CAPACITY (IBC 09 1807.2.3)


1.1 (Hb + Hs + HLat) =
2.61 kips
1.5 (Hb + Hs) =
3.17 kips

<

A S, 4

[Satisfactory]

<
<

Hp + W =
Hp + W =

4.64
4.64

kips
kips

[Satisfactory]
[Satisfactory]

0.001

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Restrained Retaining Masonry Wall Design Based on TMS 402-08 & ACI 318-08

INPUT DATA & DESIGN SUMMARY


SPECIAL INSPECTION ( 0=NO, 1=YES )
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
=
MASONRY STRENGTH
fm'
=
CONCRETE STRENGTH
fc'
REBAR YIELD STRESS
fy
=
LATERAL SOIL PRESSURE
Pa
=
=
PASSIVE PRESSURE
Pp
BACKFILL SPECIFIC WEIGHT
b
=
=
SURCHARGE WEIGHT
ws
SERVICE LATERAL FORCE
wLat
=
SERVICE GRAVITY LOAD
P
=
ECCENTRICITY
e
=
FRICTION COEFFICIENT

=
Qa
=
ALLOW SOIL PRESSURE
THICKNESS OF STEM
t
=
LT
TOE WIDTH
=
LH
=
HEEL WIDTH
HF
=
HEIGHT OF FENCE STEM
HEIGHT OF STEM
H
=
HR
=
RESTRAINED HEIGHT
hf
FOOTING THICKNESS
=
RESTRAINED BOTTOM ? (1=Yes, 0=No)
hk
KEY DEPTH
=
hp
=
SOIL OVER TOE

1
Yes
1
CMU
1.5
ksi
2.5
ksi
60
ksi
45
pcf (equivalent fluid pressure)
350
psf / ft
110
pcf
100
psf
30.1 psf
0.386 kips / ft
6
in
0.35
2.25 ksf
8
in
0.917 ft
0.917 ft
5
ft
6.83 ft
9
ft
12
in
1
Yes
0
<=No ReqD
[THE WALL DESIGN IS ADEQUATE.]
6
in
STEM REINF. (As,1)
#
8
@
8
in o.c.
As,1 LOCATION (0=at inside face, 1=at middle, 2=at each face)
0
at inside face
#
4
@
24
in
BOT. REINF.OF FOOTING (As,2)
#
4
@
18
in
TOP REINF.OF FOOTING (As,3)

ANALYSIS
SERVICE LOADS
2
Hb = 0.5 Pa H

=
=
=
=
=
=
=
=
=

Hs = ws Pa H / b
2
Hp = 0.5 Pp (hp + hf + hk)
HLat = wLat (HF + H - hp)
Ws = ws LH

1.05
0.28
0.39
0.34
0.09
0.69
0.38
0.00
0.87

Wb = H LH b
Wf = hf (LH + t + LT) c
Wk = hk t c
Ww = t ( HF + H ) m
RT = 0.5HLat(HF/HR + hp/HR +H/HR) + Pe/HR
+ 0.5HsH/HR + HbH/3HR
=
0.63
RB = HLat + Hs + Hb - RT
=
1.04
VB = Ww + P
=
1.25
FACTORED LOADS
Hb = 1.6 Hb
= 1.68 kips
Hs = 1.6 Hs
= 0.45 kips
HLat = 1.6 HLat
= 0.55 kips
Ws = 1.6 Ws
= 0.15 kips
Wb = 1.2 Wb
= 0.83 kips
Wf = 1.2 Wf
= 0.45 kips
Wk = 1.2 Wk
Ww = 1.2 Ww
P = 1.6 P

=
=
=

kips
kips
kips
kips
kips
kips
kips
kips
kips
kips
kips
kips

RT = 1.6 RT
RB = 1.6 RB

1.00
1.67

kips
kips

OVERTURNING MOMENT

0.00 kips
RB

1.04 kips
0.62 kips

=
=

Hy

H y

1.04
1.04

1.67
1.67

1.00

1.04
1.04

1.67
1.67

RESISTING MOMENT
W x

Ws
Wb
Wf

0.09
0.69
0.38

0.15
0.83
0.45

2.04
2.04
1.25

0.19
1.41
0.47

0.30
1.69
0.56

Wk

0.00

0.00

1.25

0.00

0.00

P
Ww

0.39
0.87
2.41

0.62
1.04
3.08

1.25
1.25

0.48
1.08
3.63

0.77
1.30
4.62

Wx

__
Page 55 of 533
524

OVERTURNING FACTOR OF SAFETY

SF =

Wx
=
Hy

3.48
[Satisfactory]

>

1.5

CHECK SOIL BEARING CAPACITY (ACI 318-02 SEC.15.2.2)

L = LT + t b + L H

2.50

W 1 +

e=

ft

0.18

ft

6e
L

L
, for e
6
BL
L
2 W
, for e >
3B (0.5 L e)
6

q MAX =

L Wx Hy

2
W

1.37 ksf
Qa
[Satisfactory]

<

CHECK FLEXURE CAPACITY FOR MASONRY STEM (TMS 402 2.3.3)


-1

S = Pa { ( PaH + wLat + Hs / H) + [( PaH + wLat + Hs / H) -2Pa(RB +wLat hp)]


P = VB - Ww S / (H + HF)

3.54 ft

0.99 kips, @ Mmax section

0.5

MMax = S RB - 0.5 HS S / H - Pa S / 3 - Pa (H-S) S /2 - 0.5 wLat (S - hp) =

1
kd
t
P d e
b wkd F b d
M allowable = MIN
2
3
2

, As F s

1.71

ft-kips

kd
t kd
+P e
d
3
2 3

=
>

where

=
=
=
=
=
=

te
bw
Fb
Fs
As
d

7.63
12
0.495
24
1.185
5.38

in
in
ksi
ksi
2
in

=
Em
=
Es
=
n
=
k
=
in, (TMS 402-08, 1.13.3.5)

0.018
1350
29000

3.21

M
[Satisfactory]

ksi
ksi

21.48
0.58

CHECK SHEAR CAPACITY FOR MASONRY STEM (TMS 402 2.3.5)

V = Max. Horiz. Shear


V allow able = d bwMIN

'
m

, 50

At restrained stem
0.54 kips ,

1.97
>

At bottom of stem
1.04
kips

kips ,

2.50

kips

V
[Satisfactory]

>

V
[Satisfactory]

CHECK HEEL FLEXURE CAPACITY, AS,3, FOR FOOTING (ACI 318 15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

MAX =

0.85 1 f c'
f y

u
u +t

MIN =

0.013

0.0018 h f
2
d

( q u ,3 + 2q u, heel ) b L H , for L
L H + + LH
ws
wb
wf
eu
2
6
6
L
2

M u ,3 =

q u ,3b S 2
L
L H + + LH
, for eu >
ws
wb
wf
2
6
6
L

0.85 f c' 1 1

f
where

d
eu
S

( A S, 3 ) required

M u ,3
'
0.383b d 2 f c

0.000

qu, toe
qu, heel
qu, 3

=
=
=

=
=
=

10.25 in
0.29 ft
n/a

2.09
0.37
0.94

ksf
ksf
ksf

__

0.13

in / ft

<

A S, 3

[Satisfactory]

Page 56 of 533
524

0.29 ft-kips

ft-kips

0.001

CHECK TOE FLEXURE CAPACITY, AS,2, FOR FOOTING (ACI 318 15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

MAX =

M u ,2 =

(q

u ,4

0.85 1 f c'
f y

u
u +t

+ 2q u ,toe ) b LT2
6

MIN = MIN

0.013

( A S, 2 ) required

LT w f
2L

0.71

ft-kips
where

0.85 f c' 1 1

4
0.0018 h f
,
d
3
2

M u ,2
'
0.383b d 2 f c

d
qu, 2

=
=

8.75 in
1.43 ksf

0.000

0.02

in / ft

<

A S, 2

[Satisfactory]

CHECK SLIDING CAPACITY

1.5 RB =

1.57

kips

< Hp + W =
[Satisfactory]

N/A

(Restrained)

Technical References:
1. "Masonry Designers' Guide, Third Edition" (MDG-3), The Masonry Society, 2001.
2. Alan Williams: "Structural Engineering Reference Manual", Professional Publications, Inc, 2001.
3. Alan Williams: "Structural Engineering License Review Problems and Solutions", Oxford University Press, 2003.

__
Page 57 of 533
524

0.000

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Restrained Retaining Concrete Wall Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH
REBAR YIELD STRESS
LATERAL SOIL PRESSURE
PASSIVE PRESSURE
SURCHARGE WEIGHT

fc'
fy
Pa
Pp
b
ws

SERVICE LATERAL FORCE


SERVICE GRAVITY LOAD

wLat
P

ECCENTRICITY
FRICTION COEFFICIENT
ALLOW SOIL PRESSURE
THICKNESS OF STEM

Qa

BACKFILL SPECIFIC WEIGHT

TOE WIDTH
HEEL WIDTH
HEIGHT OF FENCE STEM

t
LT
LH
HF

=
=
=
=
=

2.5
60
45
350
110

ksi
ksi
pcf (equivalent fluid pressure)
psf / ft
pcf

=
=
=

100
30.1
0.386

psf
psf
kips / ft

=
=
=
=
=
=

6
0.35
2.25
8
0.917
0.917

in
ksf
in
ft
ft

5
ft
10
ft
9
ft
RESTRAINED HEIGHT
12
in
FOOTING THICKNESS
RESTRAINED BOTTOM ? (1=Yes, 0=No)
1
Yes
hk
KEY DEPTH
=
0
<=No ReqD
hp
SOIL OVER TOE
=
6
in
#
6
@
12
STEM REINF. (As,1)
As,1 LOCATION (0=at inside face, 1=at middle, 2=at each face)
0
#
4
@
24
BOT. REINF.OF FOOTING (As,2)
TOP REINF.OF FOOTING (As,3)
#
4
@
18
HEIGHT OF STEM

=
=
=
=

H
HR
hf

[THE WALL DESIGN IS ADEQUATE.]


in o.c.
at inside face
in
in

ANALYSIS
SERVICE LOADS
Hb = 0.5 Pa H2
Hs = ws Pa H / b
Hp = 0.5 Pp (hp + hf + hk)2
HLat = wLat (HF + H - hp)
Ws = ws LH

=
=
=
=
=
=
=
=
=

2.25
0.41
0.39
0.44
0.09
1.01
0.38
0.00
1.50

kips
kips
kips
kips
kips
kips
kips
kips
kips

=
=
=

1.46
1.64
1.89

kips
kips
kips

Wb = H LH b
Wf = hf (LH + t + LT) c
Wk = hk t c
Ww = t ( HF + H ) c
RT = 0.5HLat(HF/HR + hp/HR +H/HR) + Pe/HR
+ 0.5HsH/HR + HbH/3HR
RB = HLat + Hs + Hb - RT
VB = Ww + P
FACTORED LOADS
Hb = 1.6 Hb
Hs = 1.6 Hs
HLat = 1.6 HLat
Ws = 1.6 Ws
Wb = 1.2 Wb
Wf = 1.2 Wf
Wk = 1.2 Wk
Ww = 1.2 Ww
P = 1.6 P

=
=
=
=
=
=
=
=
=

3.60
0.65
0.70
0.15
1.21
0.45

kips
kips
kips
kips
kips
kips

RT = 1.6 RT
RB = 1.6 RB

=
=

2.33
2.62

kips
kips

OVERTURNING MOMENT

0.00 kips
RB

1.80 kips
0.62 kips

Hy

H y

1.64
1.64

2.62
2.62

1.00

1.64
1.64

2.62
2.62

RESISTING MOMENT
W

Wx

W x

0.15
1.21

Wf

0.09
1.01
0.38

0.45

2.04
2.04
1.25

0.19
2.06
0.47

0.30
2.47
0.56

Wk

0.00

0.00

1.25

0.00

0.00

P
Ww

0.39
1.50
3.36

0.62
1.80
4.22

1.25
1.25

0.48
1.88
5.07

0.77
2.25
6.36

Ws
Wb

__
Page 58 of 533
524

OVERTURNING FACTOR OF SAFETY

SF =

Wx
=
Hy

3.10
[Satisfactory]

>

1.5

CHECK SOIL BEARING CAPACITY (ACI 318 15.2.2)

L = LT + t b + L H

W 1 +

q MAX =

2.50

L Wx Hy

2
W

e=

ft

0.23

6e
L

L
, for e
6
BL
L
2 W
, for e >
3B (0.5 L e)
6

=
<

2.08 ksf
Qa
[Satisfactory]

CHECK FLEXURE CAPACITY FOR CONCRETE STEM


(ACI 318 15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)
-1
2
0.5
S = Pa { ( PaH + wLat + Hs / H) + [( PaH + wLat + Hs / H) -2Pa(RB +wLat hp)] }

P = VB - Ww S / (H + HF)

3.79 ft

1.51 kips, @ Mmax section

2
3
2
2
MMax = S RB - 0.5 HS S / H - Pa S / 3 - Pa (H-S) S /2 - 0.5 wLat (S - hp) =

MAX =

0.85 1 f c'
f y

u
u +t

Mu
0.85 f c 1 1
0.383bd 2 f c'

2.93

MIN = MIN

0.013

fy

( A S, 1 ) required

0.18

in / ft

=
=
=

8.00
5.63
12

Mu

1.5 MMax =

As, 1

0.44

0.003

<

A S, 1

4
t
, 0.0018
3
d

t
d
b

'

ft-kips

0.003

in
in
in
4.39 ft-kips
2

in / ft

[Satisfactory]

CHECK SHEAR CAPACITY (ACI 318 15.5.2, 11.1.3.1, & 11.2)

V = Max. Horiz. Shear

V n = 2 bd

'

fc

At restrained section
1.28 kips ,

5.06
>

At bottom of wall
1.64
kips

kips ,

5.06

kips

V u = 1.5 V

>

[Satisfactory]

V u = 1.5 V

[Satisfactory]

CHECK HEEL FLEXURE CAPACITY, AS,3, FOR FOOTING (ACI 318 15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

MAX =

0.85 1 f c'
f y

u +t

MIN =

0.013

0.0018 h f
2
d

( q u ,3 + 2q u, heel ) b L H , for L
LH
w s + wb + LH w f
eu
2
6
6
L
2

M u ,3 =

= 0.46 ft-kips

q u ,3b S 2
L
L H + + LH

, for eu >
ws
wb
wf
L
2
6
6

0.85 f 'c 1 1

f
where

( A S, 3 ) required

d
eu
S

M u ,3
0.383b d 2 f 'c

=
=
=

0.000

__
10.25 in

qu, toe

0.37 ft
n/a

qu, heel
qu, 3

0.13

in2 / ft

<

=
=
=

A S, 3

Page 59 of 533
524

3.17

ksf

0.21
1.28

ksf
ksf

[Satisfactory]

0.001

ft

CHECK TOE FLEXURE CAPACITY, AS,2, FOR FOOTING (ACI 318 15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

MAX =

M u ,2 =

(q

u ,4

0.85 1 f c'
f y

u +t

+ 2q u ,toe ) b LT2
6

0.013

MIN = MIN

LT w f
2L

1.10

ft-kips
where

0.85 f

'
c

=
( A S, 2 ) required

M u ,2
1 1
0.383b d 2 f 'c
f

0.000

0.04

in / ft

<

A S, 2

[Satisfactory]

CHECK SLIDING CAPACITY

1.5 RB =

2.46

kips

4
0.0018 h f
,
d
3
2

< Hp + W =
[Satisfactory]

N/A

(Restrained)

__
Page 60 of 533
524

d
qu, 2

=
=

8.75 in
2.08 ksf

0.000

PROJECT :
CLIENT :
JOB NO. :
Flagpole Footing Design Based on Chapter 18 of IBC & CBC

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

INPUT DATA & DESIGN SUMMARY


IS FOOTING RESTRAINED @ GRADE LEVEL ? (1=YES,0=NO)
LATERAL FORCE @ TOP OF POLE
P=
HEIGHT OF POLE ABOVE GRADE
h=
DIAMETER OF POLE FOOTING
b=
LATERAL SOIL BEARING CAPACITY
S=
ISOLATED POLE FACTOR (IBC 09 1806.3.4)
F=
===> d =
FIRST TRIAL DEPTH

0
100
62.11
6
0.2
2
8

no
k
ft
ft
ksf / ft

ft

Use 6 ft dia x 30.55 ft deep footing unrestrained @ ground level

ANALYSIS
LATERAL BEARING @ BOTTOM :
LATERAL BEARING @ d/3 :

S 3 = FS Min ( d , 12 ' )
S 1 = FS Min
A=

REQUIRD DEPTH :

d=

d
, 12 '
3

2.34 P
bS 1

A
4.36h
1+ 1+
2
A

, FOR NONCONSTRAINED

4.25 Ph
bS 3

LATERAL FORCE @ TOP OF POLE


HEIGHT OF POLE ABOVE GRADE
DIAMETER OF POLE FOOTING
LATERAL SOIL BEARING CAPACITY
1ST TRIAL

, FOR CONSTRAINED

P =>
h =>
b =>
FS =>
TRY d1 =>

LAT SOIL BEARING @ 1/3 d

S1

=>

LAT SOIL BEARING @ 1.0 d

S3

CONSTANT 2.34P/(bS1)
REQD FOOTING DEPTH
2ND TRIAL :

NONCONSTRAINED
100.00
k
62.1
ft
6.00
ft
0.40
ksf / ft

CONSTRAINED
100.00
k
62.1
ft
6.00
ft
0.40
ksf / ft

8.00

ft

8.00

ft

1.07

ksf

1.07

ksf

=>

3.20

ksf

3.20

ksf

A =>
RQRD d =>

36.56
71.29

ft

37.08

ft

TRY d2=>

39.64

ft

22.54

ft

4.80

ksf

3.01

ksf

LAT SOIL BEARING @ 1/3 d

S1

=>

LAT SOIL BEARING @ 1.0 d

S3

=>

4.80

ksf

4.80

ksf

A =>
RQRD d =>

8.13
27.87

ft

30.27

ft

TRY d3=>

33.75

ft

26.41

ft

LAT SOIL BEARING @ 1/3 d

S1

=>

4.50

ksf

3.52

ksf

LAT SOIL BEARING @ 1.0 d

S3

=>

4.80

ksf

4.80

ksf

A =>
RQRD d =>

8.67
28.94

ft

30.27

ft

TRY d4=>

CONSTANT 2.34P/(bS1)
REQD FOOTING DEPTH
3RD TRIAL :

CONSTANT 2.34P/(bS1)
REQD FOOTING DEPTH

31.35

ft

28.34

ft

LAT SOIL BEARING @ 1/3 d

S1

=>

4.18

ksf

3.78

ksf

LAT SOIL BEARING @ 1.0 d

S3

=>

4.80

ksf

4.80

ksf

ft

30.27

ft

4TH TRIAL :

CONSTANT 2.34P/(bS1)
REQD FOOTING DEPTH
5TH TRIAL :
LAT SOIL BEARING @ 1/3 d
LAT SOIL BEARING @ 1.0 d
CONSTANT 2.34P/(bS1)
REQD FOOTING DEPTH

__
A =>
RQRD d =>

9.33
30.23

TRY d5=>

30.79

ft

29.31

ft

S1

=>

4.11

ksf

3.91

ksf

S3

=>

4.80

ksf

4.80

ksf

A =>
RQRD d =>

9.50
30.55

ft

30.27

ft

Page 61 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Deep Footing Design Based on ACI 318-08


INPUT DATA
PEDESTAL DIAMETER
SQUARE FOOTING LENGTH

c
L

FOOTING EMBEDMENT DEPTH

=
=

60
18

in
ft

Df

10.5

ft

FOOTING THICKNESS
WATER TABLE

T
h

=
=

22
8

in
ft

CONCRETE STRENGTH

fc'

ksi

REBAR YIELD STRESS

fy

60

ksi

AXIAL DEAD LOAD

PDL

73.1

AXIAL LIVE LOAD

PLL

50

LATERAL LOAD (0=WIND, 1=SEISMIC)


PLAT
SEISMIC AXIAL LOAD

=
=

SEISMIC MOMENT LOAD

MLAT

120

ft-k, SD

SEISMIC SHEAR LOAD

VLAT

11

k, SD

SURCHARGE

qs

0.1

ksf

BACKFILL SOIL WEIGHT

ws

0.1

kcf

ALLOW SOIL PRESSURE

Qa

ksf

#
#
4

10
10
spiral @

FOOTING REINFORCING SIZE


PEDESTAL VERT. REINF. SIZE
PEDESTAL SHEAR. REINF.

22
#

1
Seismic,SD
-79.175 k, SD, uplift

vertical
3

in o.c.

DESIGN SUMMARY
TOP FOOTING REINF., E. WAY =>
BOT. FOOTING REINF., E. WAY =>

2 # 10
13 # 10 @ 17 in o.c.

THE FOOTING DESIGN IS ADEQUATE.

ANALYSIS
DESIGN LOADS AT TOP OF FOOTING (IBC SEC.1605.3.2 & ACI 318-08 SEC.9.2.1)
CASE 1:
DL + LL
P
=
123 kips
CASE 2:
DL + LL + E / 1.4
P
=
67
kips
M
=
154 ft-kips
V
=
8
kips
e
=
2.3 ft, fr cl ftg
CASE 3:
0.9 DL + E / 1.4
P
=
9
kips
M
=
154 ft-kips
V
=
8
kips
e
=
16.7 ft, fr cl ftg

1.2 DL + 1.6 LL
1.2 DL + 1.0 LL + 1.0 E

0.9 DL + 1.0 E

CHECK OVERTURNING FACTOR (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
MR / MO =
Where MO =

4.20042

>

1 / 0.9

[Satisfactory]

MLAT + VLAT Df - 0.5 PLATL =

948

Pftg =

(0.15 kcf) [T L2 + ( c2/ 4)(Df - T)] =

wsat =

ws + 0.018 kcf =

wwater =

k-ft
114.63 k, footing weight

0.118 kcf, saturated soil weight

0.0625 kcf, water specifc weight

Psoil =

[ws MIN(h, Df -T)+ (wsat - wwater) MAX(Df - T - h, 0)] (L2 - c2/ 4) =

MR =

0.5 (PDL + Pftg + Psoil) L =

3982

254.75 k, soil wt

k-ft

CHECK UPLIFT CAPACITY


FGravity / FUplift =
Where FUplift =
Pftg =
Psoil =

7.51183

>

- PLAT = 79.2

1.0
k

[Satisfactory]

__

114.63

k, footing weight

407.02

k, soil weight with 30o pyramid

FGravity = PDL+ Pftg+ Psoil =

594.75 k

Page 62 of 533
524

Pu
Pu
Mu
Vu
eu
Pu
Mu
Vu
eu

=
=
=
=
=
=
=
=
=

168
59
215
11
3.7
-13
215
11
-16.1

kips
kips
ft-kips
kips
ft, fr cl ftg
kips
ft-kips
kips
ft, fr cl ftg

(cont'd)

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)


Service Loads
P
e

CASE 1
123.1
0.0

CASE 2
66.5
2.5

qs L2

32.4

32.4

0.0

k, (surcharge load)

Pftg
P

38.2
193.7

38.2
137.2

34.4
43.6

k, (footing increased)
k

M
e

0.0
0.0

250.7
1.8 < L/6

250.7
5.7 > L/6

qmax

0.6

0.7

0.5

ksf

qallow

4.0

5.3

5.3

ksf

Where

( P )
q max =

< L/6

1+

CASE 3
9.2
18.2

k
ft, (from center of footing)

k-ft, (VLat included)


ft

6e
L

L
, for e
6
L2
2 ( P )
L
, for e >
3L (0.5L e )
6

[Satisfactory]

DESIGN FOOTING FLEXURE & CHECK FLEXURE SHEAR


(ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, 12.5, 15.5.2, 11.1.3.1, & 11.2)

( Pu )
q u ,max =

1+

6eu
L

L2
2 ( Pu )

L
, for eu
6

MAX =

0.85 1 f 'c
fy

L
, for eu >
3 L (0.5L eu )
6

0.85 f c 1 1
'

Mu
0.383bd 2 f 'c

MIN = MIN 0.0018

f y

FACTORED SOIL PRESSURE


Factored Loads
CASE 1
Pu

167.7

eu

u
u +t

T
4

,
d
3

CASE 2

CASE 3

58.5

-13.4

0.0

4.0

-17.6

51.8

32.4

0.0

443.3

443.3

332.4

Pu

662.8

534.2

319.1

Mu

0.0

eu

0.0

qs L2
Pu,ftg & fill

qu, max

351.0
< L/6

0.7

2.046

k
ft, (at base, including Vu T / Pu)
k, (factored surcharge load)
k, (factored footing & backfill loads)
k

351.0
< L/6

1.1

2.010

k-ft, (VLat included)


< L/6

ft

1.346

FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 1


ColL
0
0.09 L 0.18 L 0.27 L
Section
Xu (ft, dist. from left of footing)

1.63

3.25

4.88

6.50

Mu,pedestal (ft-k)

ksf

ColR

0.73 L

0.82 L

0.91 L

11.50

13.13

14.75

16.38

18.00

-419.3 -691.85 -964.39 -1236.9 -1509.5

Vu,pedestal (k)

0.0

0.0

0.0

0.0

167.7

167.7

167.7

167.7

Pu,surch (klf)

2.88

2.88

2.88

2.88

2.88

2.88

2.88

2.88

2.88

2.88

Mu,surch (ft-k)

-3.8

-15.2

-34.2

-60.8

-190.4

-248.1

-313.3

-386.1

-466.6

Vu,surch (k)

4.7

9.4

14.0

18.7

33.1

37.8

42.5

47.2

51.8

24.63

24.63

24.63

24.63

24.63

24.63

24.63

24.63

Pu,ftg & fill (klf)

24.63

Mu,ftg & fill (ft-k)

Vu,ftg & fill (k)

-32.513 -130.05 -292.62 -520.21 -1628.3

__

24.63
-2121

167.7

-2678.8 -3301.5 -3989.3

40.0

80.0

120.0

160.1

283.2

323.2

363.2

403.2

443.3

2.05

2.05

2.05

2.05

2.05

2.05

2.05

2.05

2.05

qu,soil (ksf)

2.05

Mu,soil (ft-k)

48.618 194.47 437.56 777.89 2434.9 3171.7 4005.7 4936.9 5965.3

-59.837 -119.67 -179.51 -239.35 -423.46 -483.3 -543.14 -602.98 -662.81

Vu,soil (k)

Mu (ft-k)

12.3

49.2

110.7

196.8

196.8

110.7

49.2

12.3

Vu (kips)

-15.1

-30.3

-45.4

-60.6

60.6

45.4

30.3

15.1

Page 63 of 533
524

(cont'd)
FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 2
ColL
0
0.09 L 0.18 L 0.27 L
Section

ColR

0.73 L

0.82 L

0.91 L

Xu (ft, dist. from left of footing)

1.63

3.25

4.88

6.50

11.50

13.13

14.75

16.38

18

Mu,pedestal (ft-k)

204.64

109.5

14.366 -80.769 -175.91

Vu,pedestal (k)

0.0

0.0

0.0

0.0

58.5

58.5

58.5

58.5

Pu,surch (klf)

1.80

1.80

1.80

1.80

1.80

1.80

1.80

1.80

1.80

1.80

Mu,surch (ft-k)

-2.4

-9.5

-21.4

-38.0

-119.0

-155.0

-195.8

-241.3

-291.6

Vu,surch (k)

2.9

5.9

8.8

11.7

20.7

23.6

26.6

29.5

32.4

24.63

24.63

24.63

24.63

24.63

24.63

24.63

24.63

Pu,ftg & fill (klf)

24.63

Mu,ftg & fill (ft-k)

Vu,ftg & fill (k)

40.0

24.63

-32.513 -130.05 -292.62 -520.21 -1628.3


80.0

120.0

160.1

qu,soil (ksf)

1.29

1.35

1.42

1.48

1.55

Mu,soil (ft-k)

31.1

126.5

289.4

522.7

-2121

58.5

-2678.8 -3301.5 -3989.3

283.2

323.2

363.2

403.2

443.3

1.75

1.81

1.88

1.94

2.01

1715.7 2268.5 2907.6 3636.0 4456.8

Vu,soil (k)

-38.617 -79.142 -121.57 -165.91 -314.3 -366.42 -420.44 -476.36 -534.2

Mu (ft-k)

-3.7712 -13.019 -24.644 -35.547 172.96 101.94 47.373

Vu (kips)

4.3

6.7

7.2

5.9

FOOTING MOMENT & SHEAR AT LONGITUDINAL SECTIONS FOR CASE 3


ColL
Section
0
0.09 L 0.18 L 0.27 L

12.36

0
0

48.1

39.0

27.9

14.9

ColR

0.73 L

0.82 L

0.91 L

11.50

13.13

14.75

16.38

18.00

Xu (ft, dist. from left of footing)

Mu,pedestal (ft-k)

Vu,pedestal (k)

0.0

0.0

0.0

0.0

-13.4

-13.4

-13.4

-13.4

-13.4

1.63

3.25

4.88

6.50

384.46 406.21 427.96 449.71 471.47

Pu,surch (klf)

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

Mu,surch (ft-k)

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

Vu,surch (k)

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

0.0

18.47

18.47

18.47

18.47

18.47

18.47

18.47

18.47

Pu,ftg & fill (klf)

18.47

Mu,ftg & fill (ft-k)

Vu,ftg & fill (k)

-24.385 -97.539 -219.46 -390.16 -1221.3 -1590.8 -2009.1 -2476.1


30.0

60.0

90.0

120.0

212.4

0.69

0.75

0.82

0.88

1.09

242.4
1.15

18.47
-2992

272.4

302.4

332.4

1.22

1.28

1.35

qu,soil (ksf)

0.62

Mu,soil (ft-k)

15.337 63.416 147.33 270.19 925.34

-19.195 -40.297 -63.306 -88.222 -176.85 -209.54 -244.14 -280.64 -319.06

1239

1607.4 2033.5 2520.5

Vu,soil (k)

Mu (ft-k)

-9.0

-34.1

-72.1

-120.0

88.5

54.5

26.3

7.1

Vu (kips)

10.8

19.7

26.7

31.8

22.2

19.5

14.9

8.4

DESIGN FLEXURE
Location
Top Longitudinal
Bottom Longitudinal

Mu,max
-120.0 ft-k
196.8 ft-k

d (in)
19.37
18.37

min
reqD
max
smax
0.0004 0.0003 0.0155 no limit
0.0008 0.0006 0.0155
18

use
2 # 10
13 # 10 @ 17 in o.c.

provD
0.0006
0.0042
[Satisfactory]

CHECK FLEXURE SHEAR


Direction

Vc = 2 b d (fc')0.5

Vu,max

Longitudinal

60.6

326

check Vu < Vc

[Satisfactory]

CHECK FOOTING PUNCHING SHEAR (ACI 318-08 SEC.15.5.2, 11.11.1.2, 11.11.6, & 13.5.3.2)

v u ( psi ) =

0.5 v M u [ d + c ]
Pu R
+
J
AP

J = 0.5 ( d + c ) d
R=

P u ( d + c )
4A f

A P = b 0d

v c ( psi ) = ( 2 + y ) f 'c

A f = L2

y = MIN 2,

v = 0.4

d +c 2 d 3
+
2
3

, 40

b0

b0 = ( c + d )

__

Case

Pu

Mu

b0

Af

Ap

vu (psi)

vc

1
2
3

198.4
89.2
9.6

0.0
330.8
330.8

246.2
246.2
246.2

0.4
0.4
0.4

1.0
1.0
1.0

2.0
2.0
2.0

324.0
324.0
324.0

31.4
31.4
31.4

20.5
9.2
1.0

171.3
171.3
171.3

39.3
35.2
19.4

164.3
164.3
164.3

0.75

where

(ACI 318-08, Section 9.3.2.3 )

Page 64 of 533
524

[Satisfactory]

(cont'd)
CHECK PEDESTAL REINF. LIMITATIONS
max
=
0.08 (ACI 318-08, Section 10.9)
min
=
0.01 (ACI 318-08, Section 10.9)
smax
smin

=
=

3
1

provd

0.011
[Satisfactory]

(ACI 318-08, Section 7.10.4.3)


(ACI 318-08, Section 7.10.4.3)

sprovd

__
Page 65 of 533
524

in
[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Soil Pressure Determination for Irregular Footing


INPUT DATA & ANALYSIS RESULTS
FOOTING EDGE POINT & REACTION PRESSURE

COLUMN LOCATION & BASE LOAD

EDGE

COL.

Mx

My

POINT
1
2
3
4

(ft)
0
0
38
38

(ft)
0
21.5
21.5
0

(psf)
47
215
196
28

NO.
1
2
3
4
5
6
7
8
9
10

(ft)
9.33
13
25
28.67
17.6
21.2
9.33
13
25
28.67

(ft)
4.47
4.47
4.47
4.47
10.5
10.5
19.73
19.73
19.73
19.73

(kips)
10.6
20
20
10.6
7
7
20
20
10.6
20

(ft-k)

(ft-k)

WALL LOCATION & UNIFORM LOAD


WALL
START
END
NO.
X (ft)
Y (ft)
X (ft)
Y (ft)

w
(k/ft)

NET PRESSURE OF FOOTING SELF WEIGHT

THE MAXIMUM SOIL PRESSURE

215

psf

0.3

k/ft2

@ POINT

ANALYSIS
Footing Area
A=
-817.0

ft2

Qmax
Centroid of Footing (COF)
Xc =

19.0

ft

Yc =

10.8

ft

Center of Gravity (COG)


Xg =

19.5

ft

Yg =

8.3

ft

P =

-99.3

kips

COF
Moment of Inertia

COG

Ixc =

31472

ft4

Iyc =

98312

ft4

Moment of Inertia for Principle Axes


4
Iu =
31472 ft

(0,0)

Notes:

1.
2.
3.
4.

__

Iv =

98312

0.00

ft4
deg

Assume that the footing is rigid without any deformation.


The footing self pressure should be net pressure, (0.15 kcf - 0.11 kcf) (Thk.), to check allowable soil capacity.
Use two end columns, uplift & download, to input the shear wall bending load.
To design concrete, may use 1.5 time section forces of ADS level.

Page 66 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Mat Boundary Spring Generator


INPUT DATA & DESIGN SUMMARY
L
=
55
ft
B
=
31
ft
ft2
GRID TRIBUTARY AREA
A
=
1
3
K1
= 100 lb / in
MODULUS OF SUBGRADE
(Obtained from the soil report for 1' x 1' sf plate load test,
in the absence of a soil report obtain from table below )
FOUNDATION LENGTH
FOUNDATION WIDTH

4.8
2.4
1.2

INSIDE SPRING VALUE


EDGE SPRING VALUE
CORNER SPRING VALUE

kips / inch, at each joint


kips / inch, at each joint
kips / inch, at each joint

ANALYSIS

k s=

k11

( for B = L )

k12

( for B < L )

k11=k1

B+1
2B

k12 = k1

B+1
2B

33.5

lb / in3

0.5L
+1
B
1.5

26.6

lb / in3

46

k / ft3

33.5

lb / in3

58

k / ft3

TYPICAL VALUES OF MODULUS OF SUBGRADE REACTIONS, K1 (lb / in3 )


TYPE OF MATERIAL

5 to 8%

Silts and clays (liquid limit >50)


(OH, CH, MH )

175

150

125

100

75

50

25

Silts and clays (liquid limit <50)


(OL, CL, ML )

200

175

150

125

100

75

50

300

250

225

200

150

Gravelly sands
(SW & SP )

Over 300

300

250

Silty and clayey gravels


(GM & GC )

Over 300

Over 300

300

Gravel and sand

Over 300

Over 300

Silty and clay sands


(SM & SH )

9 to 12%

MOISTURE CONTENT
13 to 16%

1 to 4%

__
Page 67 of 533
524

17 to 20%

21 to 24%

25 to 28%

> 28%

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Plain Concrete Footing Design Based on ACI 318-08


INPUT DATA

DESIGN SUMMARY

COLUMN WIDTH

c1

in

FOOTING WIDTH

3.00

COLUMN DEPTH

c2

in

FOOTING LENGTH

3.00

ft

BASE PLATE WIDTH

b1

in

FOOTING THICKNESS

in

BASE PLATE DEPTH

=
=
=

10
13
8

k
k
k

b2

in

FOOTING CONCRETE STRENGTH


REBAR YIELD STRESS
AXIAL DEAD LOAD

fc'
fy
PDL

=
=
=

2.5
60
2

ksi
ksi
k

AXIAL LIVE LOAD

PLL

4.5

LATERAL LOAD (0=WIND, 1=SEISMIC)


PLAT
SEISMIC AXIAL LOAD

=
=

1
6.5

Seismic,SD
k, SD

SURCHARGE
SOIL WEIGHT
FOOTING EMBEDMENT DEPTH
FOOTING THICKNESS
ALLOWABLE SOIL PRESSURE
FOOTING WIDTH
FOOTING LENGTH

=
=
=
=
=
=
=

0
0.11
0.50
8
1
3
3

ksf
kcf
ft
in
ksf
ft
ft

qs
ws
Df
T
Qa
B
L

ft

THE FOOTING DESIGN IS ADEQUATE.


ANALYSIS
DESIGN LOADS (IBC SEC.1605.3.2 & ACI 318-08 SEC.9.2.1)
CASE 1:
DL + LL
P =
7
k
CASE 2:
DL + LL + E / 1.4
P =
11
k
CASE 3:
0.9 DL + E / 1.4
P =
7
k

1.2 DL + 1.6 LL
1.2 DL + 1.0 LL + 1.0 E
0.9 DL + 1.0 E

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)


CASE 1
CASE 2
P
q MAX =
=
0.75
ksf,
1.26 ksf,

CASE 3
0.74 ksf

BL

q MAX

<

Pu
Pu
Pu

kQa,

[Satisfactory]

where k = 1 for gravity loads, 4/3 for lateral loads.

DESIGN FOR FLEXURE (ACI 318-08 SEC.22.5.1)

M n = MIN 5

where

Mu =

'
'
f c S , 0.85 f cS

=
=

( 0.5L 0.25b10.25c1)

4.80

ft-kips

0.6 (ACI 318-08, Section 9.3.5 )


elastic section modulus of section
2

P u ,max

2L

3.73

<

ft-kips

384

in3

[Satisfactory]

CHECK FLEXURE SHEAR (ACI 318-08 SEC.22.5.4)

4
3

V n =

'

f c BT

where

11.52 kips

0.6

(ACI 318-08, Section 9.3.5 )

P u ,max
V u = ( 0.5L 0.25b1 0.25c1 T )
L

2.79

<

kips

[Satisfactory]

CHECK PUNCHING SHEAR (ACI 318-08 SEC.22.5.4)

V n = MIN

4
8
+
, 2.66
3 3 c

where

V u = P u ,ma x 1

=
=

f c ( c1 + c2 + b1 + b2 + 4T ) T
'

__
=

31.28

kips

0.6 (ACI 318-08, Section 9.3.5 )


ratio of long side to short side of concentrated load

1 b1 + c 1
+T
BL
2

b2+ c2 +T
2

11.85

Page 68 of 533
524

ft-kips

1.43

<

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Design of Conventional Slabs on Expansive Soil Grade Based on ACI 360


1. DESIGN METHODS
1.1 DIVIDE AN IRREGULAR FOUNDATION PLAN INTO OVERLAPPING RECTANGLES AND USING
THIS SPREADSHEET DESIGN EACH RECTANGULAR SECTION SEPARATELY.
1.2 THE POST-TENSION INSTITUTE (PTI) METHOD IS ACCEPTABLE FOR THE DESIGN OF
NONPRESTRESSED SLAB ON GRADE (IBC 09 1808.6.2). THE DESIGNER MAY SELECT EITHER
NONPRESTRESSED REINFORCEMENT USING THIS SPREADSHEET, OR POST-TENSIONED
REINFORCEMENT IF REQUIRED (ACI 360, 9).

2. INPUT DATA & DESIGN SUMMARY


2.1 SOILS PROPERTIES
ALLOWABLE SOIL-BEARING PRESSURE

qallow

EDGE MOISTURE VARIATION DISTANCE

em

DIFFERENTIAL SOIL MOVEMENT

ym

=
=
=
=
=

2000

=
=
=
=
=
=
=
=
=
=
=
=
#
@

psf

ft, for center lift

4.5

ft, for edge lift

2.68

in, for center lift

0.3

in, for edge lift

164

ft

125

ft

2.2 STRUCTURAL DATA AND MATERIALS PROPERTIES


SLAB LENGTH

SLAB WIDTH

SLAB THICKNESS

PERIMETER LOADING

MAX BEARING LOADING ON THE SLAB

Pb

ADDED DEAD LOAD

DL

LIVE LOAD

LL

AVERAGE STIFFENING BEAM SPACING, L DIRECTION

SL

AVERAGE STIFFENING BEAM SPACING, B DIRECTION

SB

STIFFENING BEAM DEPTH

STIFFENING BEAM WIDTH

CONCRETE STRENGTH

f'c

REINFORCEMENT IN THE BOTTOM OF STIFFENING BEAM

SLAB REINFORCEMENT

in

270

plf

270

plf

50

psf

125

psf

30

ft

30

ft

24

in

20

in

ksi

THE DESIGN IS ADEQUATE.

6
18

in o.c., with

1.5

in clear from top of slab, each way.

3. ASSUME A TRIAL SECTION


3.1 ASSUME BEAM DEPTH AND SPACING
ALLOWABLE DIFFERENTIAL DEFLECTION, FOR CENTER LIFT, AT L DIRECTION
allow = 12 MIN(L, 6) / C =

Where

=
=

ALLOWABLE DIFFERENTIAL DEFLECTION, FOR CENTER LIFT, AT B DIRECTION

1.60

in

allow = 12 MIN(B, 6) / C =

ft

Where

360

ALLOWABLE DIFFERENTIAL DEFLECTION, FOR EDGE LIFT, AT L DIRECTION


allow = 12 MIN(L, 6) / C =

Where

=
=

1.60

in

ft

360

ALLOWABLE DIFFERENTIAL DEFLECTION, FOR EDGE LIFT, AT B DIRECTION

0.80

in

allow = 12 MIN(B, 6) / C =

ft

Where

720

BEAM DEPTH, FOR CENTER LIFT, AT L DIRECTION

=
=

0.80

in

ft

720

BEAM DEPTH, FOR CENTER LIFT, AT B DIRECTION

h = [(ym L)0.205 SB1.059 P0.523 em1.296 / 380 allow ]0.824 =

13.56

h = [(ym B)0.205 SL1.059 P0.523 em1.296 / 380 allow ]0.824 =

in

BEAM DEPTH, FOR EDGE LIFT, AT L DIRECTION

12.95

in

7.58

in

BEAM DEPTH, FOR EDGE LIFT, AT B DIRECTION

h = [L0.35 SB0.88 em0.74 ym0.76 / 15.9 allow P0.01]1.176 =


GOVERNING h =

=
=

13.56

8.47

h = [B0.35 SL0.88 em0.74 ym0.76 / 15.9 allow P0.01]1.176 =

in

<

in

ACTUAL h =

24.00

in

22

in2

[Satisfactory]

3.2 DETERMINE SECTION PROPERTIES


L DIRECTION
As

B DIRECTION
=

Es / Ec =

17

in2

9.29

yb

18.75

beams

As

in

Es / Ec =
3

CGS

21.75

in

St

64268

in

9935

in2

Sb

17995

in3

337410

in4

9.29

yb

19.00

beams
in

CGS

22.25

in

St

80834

in3

12703

in2

Sb

21276

in3

404232

in4

4. CALCULATE MAXIMUM APPLIED SERVICE MOMENTS


4.1 CENTER LIFT MOMENT AT L DIRECTION
ML = A0 (B em1.238 + C) =
Where

4.96

CENTER LIFT MOMENT AT B DIRECTION


ft-kips / ft

MB = (58 + em) ML / 60, for L /B > 1.1

A0 = (L0.013 SB0.306 h0.688 P0.534 ym0.193) / 727 =


B = 1, for em < 5
B = MIN[(ym - 1) / 3, 1], for em > 5
C = 0, for em < 5

__
=

C = MAX{[8 - (P - 613) / 255] (4 - ym) / 3], 0}, for em > 5


4.2 EDGE LIFT MOMENT AT L DIRECTION
ML = SB0.10 (h em)0.78 ym0.66 / (7.2 L0.0065 P0.04) =

MB = ML, for L /B < 1.1

0.891

5.12

ft-kips / ft

3.25

ft-kips / ft

1.00

0.00

EDGE LIFT MOMENT AT B DIRECTION

2.63

ft-kips / ft

MB = h0.35 (19 + em) ML / 57.75, for L /B > 1.1

MB = ML, for L /B < 1.1

Page 69 of 533
524

5. CHECK FLEXURAL CONCRETE STRESSES


5.1 ALLOWABLE CONCRETE STRESSES
FLEXURAL TENSILE STRESS

ft,allow = - 6 (fc')0.5 =

-0.329

ksi

FLEXURAL COMPRESSIVE STRESS

fc,allow = - 0.45 fc' =

1.350

ksi

5.2 TOP STRESS, FOR CENTER LIFT MOMENT, AT L DIRECTION


f = - ML / St =

-0.116

>
<

Then

TOP STRESS, FOR CENTER LIFT MOMENT, AT B DIRECTION

ksi

f = - MB / St =

ft,allow

[Satisfactory]

fc,allow

[Satisfactory]

5.3 BOTTOM STRESS, FOR CENTER LIFT MOMENT, AT L DIRECTION


f = ML / Sb =

0.413

f = MB / Sb =

ft,allow

[Satisfactory]

fc,allow

[Satisfactory]

-0.219

Then

0.061

[Satisfactory]

fc,allow

[Satisfactory]

Where

Ec = (0.5) 57000 (fc')


Es =

[Satisfactory]

[Satisfactory]

ft,allow

[Satisfactory]

fc,allow

[Satisfactory]

ksi

>
<

ft,allow

[Satisfactory]

fc,allow

[Satisfactory]

= (Ec I / Es)1/4 / 12 =
1561009

psi

13.208

ft

Ec = (0.5) 57000 (fc')0.5 =

Where

psi, soil

Es =

6.2 ALLOWABLE DIFFERENTIAL DEFLECTION AT L DIRECTION

1561009

1000

psi

psi, soil

ALLOWABLE DIFFERENTIAL DEFLECTION AT B DIRECTION

FOR CENTER LIFT

FOR CENTER LIFT

allow = 12 MIN(L, 6) / C =
Where

[Satisfactory]

fc,allow

RELATIVE STIFFNESS LENGTH AT B DIRECTION


ft

1000

0.079

Then

6.1 RELATIVE STIFFNESS LENGTH AT L DIRECTION


0.5

ft,allow

BOTTOM STRESS, FOR EDGE LIFT MOMENT, AT B DIRECTION

[Satisfactory]

12.624

[Satisfactory]

ksi

>
<

f = MB / St =

>
ft,allow
<
fc,allow
6. CHECK DIFFERENTIAL DEFLECTIONS
= (Ec I / Es)1/4 / 12 =

-0.301

Then

ksi

Then

[Satisfactory]

fc,allow

ksi

>
<

f = - MB / Sb =

ft,allow

5.5 BOTTOM STRESS, FOR EDGE LIFT MOMENT, AT L DIRECTION


f = ML / St =

ft,allow

TOP STRESS, FOR EDGE LIFT MOMENT, AT B DIRECTION

ksi

>
<

0.474

Then

5.4 TOP STRESS, FOR EDGE LIFT MOMENT, AT L DIRECTION


f = - ML / Sb =

ksi

>
<

BOTTOM STRESS, FOR CENTER LIFT MOMENT, AT B DIRECTION

ksi

>
<

Then

-0.125

Then

2.64

in

360

allow = 12 MIN(B, 6) / C =

2.52

360

allow = 12 MIN(B, 6) / C =

1.26

720

Where

FOR EDGE LIFT

in

FOR EDGE LIFT

allow = 12 MIN(L, 6) / C =
Where

1.32

in

720

Where

6.3 EXPECTED DIFFERENTIAL DEFLECTION WITHOUT PRESTRESSING

in

EXPECTED DIFFERENTIAL DEFLECTION WITHOUT PRESTRESSING

FOR CENTER LIFT, AT L DIRECTION

FOR CENTER LIFT, AT B DIRECTION

0 = (ym L)0.205 SB1.059 P0.523 em1.296 / (380 h1.214) =

0.80

<

0 = (ym B)0.205 SL1.059 P0.523 em1.296 / (380 h1.214) =

in
allow

0.76

<

[Satisfactory]

in
allow

[Satisfactory]

FOR EDGE LIFT, AT L DIRECTION

FOR EDGE LIFT, AT B DIRECTION

0 = L0.35 ym0.76 SB0.88 em0.74 / (15.9 h0.85 P0.01) =

0.58

<

0 = B0.35 ym0.76 SL0.88 em0.74 / (15.9 h0.85 P0.01) =

in
allow

0.53

<

[Satisfactory]

in
allow

[Satisfactory]

7. CHECK SHEAR CAPACITY


7.1 APPLIED SERVICE LOAD SHEAR AT L DIRECTION

APPLIED SERVICE LOAD SHEAR AT B DIRECTION

FOR CENTER LIFT


VL = L

0.09

0.71

SB

0.43

FOR CENTER LIFT


0.44

0.16

ym

0.93

em

/ 1940 =

1.786

VB = B0.19 SL0.45 h0.20 P0.54 ym0.04 em0.97 / 1350 =

kips/ft

FOR EDGE LIFT


VL = L

0.07

0.4

0.03

1.327

kips/ft

1.063

kips/ft

FOR EDGE LIFT


0.67

ym

0.16

em

0.015

/ (3.0 SB

) =

1.084

0.07

kips/ft

VB = B

7.2 ALLOWABLE CONCRETE SHEAR STRESS, AT L DIRECTION


vc = 2 (fc')0.5 =

0.110

0.4

0.03

0.67

ym

0.16

em

0.015

/ (3.0 SL

) =

ALLOWABLE CONCRETE SHEAR STRESS, AT B DIRECTION


vc = 2 (fc')0.5 =

ksi

7.3 SHEAR STRESS OF RIBBED FOUNDATION, AT L DIRECTION

0.110

ksi

SHEAR STRESS OF RIBBED FOUNDATION, AT B DIRECTION

FOR CENTER LIFT

FOR CENTER LIFT

v = V B / (n h b) =

0.078

<

ksi

vc

v = V L / (n h b) =

0.065

ksi

[Satisfactory]

<

vc

[Satisfactory]

FOR EDGE LIFT

FOR EDGE LIFT

v = V B / (n h b) =

0.047

<

ksi

vc

v = V L / (n h b) =

0.052

ksi

[Satisfactory]

<

vc

[Satisfactory]

8. CHECK SOIL BEARING


8.1 APPLIED LOADING
(b)(Total Length) = 3028.333333 ft2
psf
1893

SLAB WEIGHT

150 L B t

1281250

lbs

BEAM BEARING AREA

ADDED DL

DL L B

1025000

lbs

SOIL PRESSURE

LIVE LOAD

LL L B

2562500

lbs

<

BEAM WEIGHT

150 (h-t) b (Total Length)

708146

lbs

[Satisfactory]

PERIMETER LOAD

P (2L + 2B)

156060

lbs

q = Total Load / THE AREA =

qallow

9. CHECK SLAB STRESS DUE TO LOAD-BEARING PARTITIONS


9.1 RELATIVE STIFFNESS LENGTH AT L DIRECTION
Mmax = Pb / 4 =
Where

2.03

RELATIVE STIFFNESS LENGTH AT B DIRECTION

= MIN[(Ec t3 / 3 ks)0.25, SB] =

ks =

lb / in3

9.2 TENSILE STRESS AT L DIRECTION


f = - Mmax / 2 t2 =

Technical References:

30

ft

Where

__

2.03

ft-kips / ft

= MIN[(Ec t3 / 3 ks)0.25, SL] =

ks =

lb / in3

TENSILE STRESS AT B DIRECTION

-0.041

>

Mmax = Pb / 4 =

ft-kips / ft

ft,allow

ksi

f = - Mmax / 2 t2 =

[Satisfactory]

1. "Design of Slabs on Grade, ACI Committee 360R-06", American Concrete Institute, 2006.

2. "Design and Construction of Post-Tensioned Slab-on-Ground, Second Edition", The Post-Tensioning Institute, 2004.
3. "1997 Uniform Building Code, Volume 2", International Conference of Building Officials, 1997.

Page 70 of 533
524

-0.041

>

ft,allow

ksi
[Satisfactory]

30

ft

PROJECT :

PAGE :

CLIENT :
JOB NO. :

DESIGN BY :
REVIEW BY :

DATE :

Design of Conventional Slabs on Compressible Soil Grade Based on ACI 360


1. INPUT DATA & DESIGN SUMMARY
1.1 SOILS PROPERTIES
qallow

ALLOWABLE SOIL-BEARING PRESSURE

EXPECTED SETTLEMENT BY GEOTECHNICAL ENR

=
=

2000

psf

0.75

in

=
=
=
=
=
=
=
=

164

ft

=
=
=
=
#
@

1.2 STRUCTURAL DATA AND MATERIALS PROPERTIES


SLAB LENGTH

SLAB WIDTH

SLAB THICKNESS

PERIMETER LOADING

MAX BEARING LOADING ON THE SLAB

Pb

ADDED DEAD LOAD

DL

LIVE LOAD

LL

AVERAGE STIFFENING BEAM SPACING, L DIRECTION

SL

AVERAGE STIFFENING BEAM SPACING, B DIRECTION

SB

STIFFENING BEAM DEPTH

STIFFENING BEAM WIDTH

b
f'c

CONCRETE STRENGTH
REINFORCEMENT IN THE BOTTOM OF STIFFENING BEAM

SLAB REINFORCEMENT

125

ft

in

270

plf

270

plf

50

psf

125

psf

30

ft

30

ft

24

in

20

in

ksi

6
18

in o.c., with

1.5

in clear from top of slab, each way.


THE DESIGN IS ADEQUATE.

2. DETERMINE SECTION PROPERTIES


L DIRECTION
n

B DIRECTION
=

As

338782

in4

yb

18.80

in

As

22

St

65100

in3

Es / Ec =

18024

in3

in

17

E s / Ec =

18.58

CGS

21.75

in

10090

in2

Sb

in2

18.58

CGS

22.25

in

12906

in2

406345

in4

yb

19.05

in

St

82096

in3

Sb

21330

in3

3. CALCULATE MAXIMUM APPLIED SERVICE MOMENTS


L DIRECTION

B DIRECTION

McsL = ( / nsL)0.5 MnsL =

0.83

1.35

MnsL = h

Where

0.36

SB

ft-kips / ft

0.12

/ 80 L

0.10

0.96

nsL = L1.28 SB0.80 / 133 h0.28 P0.62 =

McsS = McsL (970-h) / 880 =

0.90

nsL = L1.28 SB0.80 / 133 h0.28 P0.62 =

0.70

ft-kips / ft

ft-kips / ft

1.00

4. CHECK FLEXURAL CONCRETE STRESSES


4.1 ALLOWABLE CONCRETE STRESSES
FLEXURAL TENSILE STRESS

f t,allow = - 6 (f c')0.5 =

-0.329

ksi

FLEXURAL COMPRESSIVE STRESS

f c,allow = - 0.45 f c' =

1.350

ksi

4.2 TOP STRESS, FOR CENTER LIFT MOMENT, AT L DIRECTION


f = M L / St =

0.019

Then

TOP STRESS, FOR CENTER LIFT MOMENT, AT B DIRECTION


f = MB / St =

ksi

>

f t,allow

[Satisfactory]

<

f c,allow

[Satisfactory]

Then

4.3 BOTTOM STRESS, FOR CENTER LIFT MOMENT, AT L DIRECTION


f = - M L / Sb =

-0.069

Then

0.021

f = - MB / Sb =

f t,allow

[Satisfactory]

<

f c,allow

[Satisfactory]

f t,allow

[Satisfactory]

<

f c,allow

[Satisfactory]

BOTTOM STRESS, FOR CENTER LIFT MOMENT, AT B DIRECTION

ksi

>

ksi

>

Then

-0.083

ksi

>

f t,allow

[Satisfactory]

<

f c,allow

[Satisfactory]

5. CHECK DIFFERENTIAL DEFLECTIONS


5.1 RELATIVE STIFFNESS LENGTH AT L DIRECTION
= (Ec I nsL / Es )1/4 / 12 =

13.571

RELATIVE STIFFNESS LENGTH AT B DIRECTION

Ec = (0.5) 57000 (f c')0.5 =

Where

Es =

1000

I =

338782

= (Ec I nsB / Es )1/4 / 12 =

ft
1561009

psi

Where

psi, soil

Es =

in4

I =

5.2 ALLOWABLE DIFFERENTIAL DEFLECTION AT L DIRECTION


allow = 12 MIN(L, 6) / C =
Where

0.51

0.25

<

1000
406345

allow = 12 MIN(B, 6) / C =

0.49

1920

Where

5.3 DIFFERENTIAL DEFLECTION WITHOUT PRESTRESSING


0{1.78 - 0.103 h -1.65E-03 P + 3.95E-07 P P)

6.1 APPLIED SERVICE LOAD SHEAR AT L DIRECTION


VcsL = ( / nsL)

0.30

Where

VnsL = h0.90 (PSB)0.30 / 550 L0.10 =

VnsL =

0.260

kips/ft

6.2 ALLOWABLE CONCRETE SHEAR STRESS, AT L DIRECTION


v c = 2 (f c')0.5 =

0.110

6.3 SHEAR STRESS OF RIBBED FOUNDATION, AT L DIRECTION


v = V B / (n h b) =

0.010

ksi

psi

in4

in

cs = en0{1.78 - 0.103 h -1.65E-03 P + 3.95E-07 P P) =

0.25

allow

<

in
allow

[Satisfactory]

__

APPLIED SERVICE LOAD SHEAR AT B DIRECTION


VcsS = VcsL (116-h) / 94 =

0.284

0.255

kips/ft

kips/ft

ALLOWABLE CONCRETE SHEAR STRESS, AT B DIRECTION


v c = 2 (f c')0.5 =

ksi

1561009
psi, soil

DIFFERENTIAL DEFLECTION WITHOUT PRESTRESSING


in

[Satisfactory]

6. CHECK SHEAR CAPACITY

ft

ALLOWABLE DIFFERENTIAL DEFLECTION AT B DIRECTION

in

1920

cs = en

13.020

Ec = (0.5) 57000 (f c')0.5 =

0.110

ksi

SHEAR STRESS OF RIBBED FOUNDATION, AT B DIRECTION

<

vc

v = V L / (n h b) =

[Satisfactory]

Page 71 of 533
524

0.015

ksi

<
[Satisfactory]

vc

(cont'd)
7. CHECK SOIL BEARING
7.1 APPLIED LOADING
SLAB WEIGHT

150 L B t

1281250

lbs

BEAM BEARING AREA

ADDED DL

DL L B

1025000

lbs

SOIL PRESSURE

(b)(Total Length) =

2982

q = Total Load / THE AREA =

1923

LIVE LOAD

LL L B

2562500

lbs

<

BEAM WEIGHT

150 (h-t) b (Total Length)

708146

lbs

[Satisfactory]

PERIMETER LOAD

P (2L + 2B)

156060

lbs

ft2
psf
qallow

8. CHECK SLAB STRESS DUE TO LOAD-BEARING PARTITIONS


8.1 RELATIVE STIFFNESS LENGTH AT L DIRECTION
Mmax = Pb / 4 =
Where

2.03

RELATIVE STIFFNESS LENGTH AT B DIRECTION

= MIN[(Ec h3 / 3 ks)0.25, SB] =

ks =

ft

Where

2.03

ft-kips / ft

= MIN[(Ec h3 / 3 ks)0.25, SB] =

ks =

lb / in3

TENSILE STRESS AT B DIRECTION


-0.041

>

30.000

lb / in3

8.2 TENSILE STRESS AT L DIRECTION


f = - Mmax / 2 t2 =

Mmax = Pb / 4 =

ft-kips / ft

f t,allow

f = - Mmax / 2 t2 =

ksi

-0.041

>

[Satisfactory]

__
Page 72 of 533
524

f t,allow

ksi
[Satisfactory]

30.000

ft

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Design of PT Slabs on Expansive Soil Ground Based on Standards of PTI 3rd Edition
1. DESIGN METHODS
1.1

MAKE SURE THAT THE FOUNDATION PLAN SATISFIES THE SHAPE FACTOR REQUIREMENT:
SF = (ENTIRE FOUNDATION PERIMETER) / (ENTIRE FOUNDATION AREA)
24 , (Sec. 4.5.1)

1.2

DIVIDE AN IRREGULAR FOUNDATION PLAN INTO OVERLAPPING RECTANGLES AND USING


THIS SPREADSHEET DESIGN EACH RECTANGULAR SECTION SEPARATELY.

1.3

ONCE THE RIBBED FOUNDATION HAS BEEN DESIGNED TO SATISFY MOMENT, SHEAR, AND
DIFFERENTIAL DEFLECTION REQUIREMENTS, IT MAY BE CONVERTED TO AN EQUIVALENT
UNIFORM THICKNESS FOUNDATION.

2. INPUT DATA & DESIGN SUMMARY


2.1 SOILS PROPERTIES (FROM SOIL REPORT / GEOTECHNICAL INVESTIGATION)
ALLOWABLE SOIL-BEARING PRESSURE

qallow

EDGE MOISTURE VARIATION DISTANCE

em

DIFFERENTIAL SOIL MOVEMENT

ym

SLAB-SUBGRADE FRICTION COEFFICIENT

=
=
=
=
=
=

2000

=
=
=
=
=
=
=
=
=
=
=
=

42

psf

ft, for center lift

5.2

ft, for edge lift

0.07

in, for center lift

0.46

in, for edge lift

0.75

2.2 STRUCTURAL DATA AND MATERIALS PROPERTIES


SLAB LENGTH

SLAB WIDTH

SLAB THICKNESS

PERIMETER LOADING

MAX BEARING LOADING ON THE SLAB

Pb

ADDED DEAD LOAD

DL

LIVE LOAD

LL

AVERAGE STIFFENING BEAM SPACING, L DIRECTION

SL

AVERAGE STIFFENING BEAM SPACING, B DIRECTION

SB

STIFFENING BEAM DEPTH

STIFFENING BEAM WIDTH

CONCRETE STRENGTH

f'c

ft

24

ft

in

695

plf

2700

plf

15

psf

40

psf

12

ft

12

ft

14.5

in

12

in

ksi

SLAB PRESTRESSING TENDONS, L DIRECTION

tendons w/

0.153

in2 at each tendon.

SLAB PRESTRESSING TENDONS, B DIRECTION

tendons w/

0.153

in2 at each tendon.

TENDON IN THE BOTTOM OF EACH BEAM

tendons w/

0.153

174

EFFECTIVE PRESTRESS AFTER ALL LOSSES EXCEPT SG

fe

CONVERT UNIFORM THICKNESS (Sec. 6.12) ?

in2 (only for edge lift governing required)


ksi

No
THE DESIGN IS ADEQUATE.
SUGGESTED RATIO OF EXPECTED ELONGATION IS 0.00777

3. DETERMINE SECTION PROPERTIES


L DIRECTION
n
A

B DIRECTION
=

1530

yb
in

2
4

19969

in

CGS

9.03

in

St

=
=

10.71
5267

in
in

3
3

Sb

1865

in

-1.68

in

2646

in2

33706

in

CGS

9.20

in

yb

10.77

in

St

9046

in3

Sb

3129

in3

-1.58

in

4. CALCULATE MAXIMUM APPLIED SERVICE MOMENTS (Sec. 6.8)


4.1 CENTER LIFT MOMENT AT L DIRECTION
For em =

ML = A0 (B em1.238 + C) =
Where

CENTER LIFT MOMENT AT B DIRECTION

ft

For em =
2.05

ft-kips / ft

A0 = (L0.013 SB0.306 h0.688 P0.534 ym0.193) / 727 =


B = 1, for em < 5
B = MIN[(ym - 1) / 3, 1], for em > 5

ft (Sec. 4.3.2)

ML = A0 (B em1.238 + C) =
Where

2.81

=
=

C
USE

ML =

2.29

ft-kips / ft

2.95

ft-kips / ft

2.49

ft-kips / ft

10.06
For em =

ft-kips / ft

ft (Sec. 4.3.2)

MB = (58 + em) ML / 60, for L /B > 1.1

A0 = (L0.013 SB0.306 h0.688 P0.534 ym0.193) / 727 =


B

-0.31

C = 0, for em < 5

ft

MB = ML, for L /B < 1.1

0.383

C = MAX{[8 - (P - 613) / 255] (4 - ym) / 3], 0}, for em > 5


For em =

MB = (58 + em) ML / 60, for L /B > 1.1

0.383

MB = ML, for L /B < 1.1

1.00
0.00

2.81

ft-kips / ft

USE

4.2 EDGE LIFT MOMENT AT L DIRECTION

MB =

2.95

ft-kips / ft

EDGE LIFT MOMENT AT B DIRECTION

ML = SB0.10 (h em)0.78 ym0.66 / (7.2 L0.0065 P0.04) =

2.33

ft-kips / ft

MB = h0.35 (19 + em) ML / 57.75, for L /B > 1.1


MB = ML, for L /B < 1.1

5. CHECK FLEXURAL CONCRETE STRESSES (Sec. 6.5)


5.1 ALLOWABLE CONCRETE STRESSES
FLEXURAL TENSILE STRESS

ft,allow = - 6 (fc')0.5 =

-0.329

ksi

FLEXURAL COMPRESSIVE STRESS

fc,allow = - 0.45 fc' =

1.350

ksi

(cont'd)
5.2 TOP STRESS, FOR CENTER LIFT MOMENT, AT L DIRECTION
f= Pr / A - ML / St + Pr e / St =
Where

-0.092

ksi

f = Pr / A - MB / St + Pr e / St =

Pr = Pe - SG =

182.71

Pe = fe Aps =

212.98

>
<

kips

Where

Pe = fe Aps =
30.27

ft,allow

[Satisfactory]

fc,allow

[Satisfactory]

>
<

Then

0.718

>
<

[Satisfactory]
[Satisfactory]

[Satisfactory]
[Satisfactory]

>
<

>
<

Then

[Satisfactory]
[Satisfactory]

kips

[Satisfactory]

fc,allow

[Satisfactory]

0.778

ksi

ft,allow

[Satisfactory]

fc,allow

[Satisfactory]

-0.100

ksi

ft,allow

[Satisfactory]

fc,allow

[Satisfactory]

f = Pr / A + MB / St + Pr e / St =

fc,allow

30.27

BOTTOM STRESS, FOR EDGE LIFT MOMENT, AT B DIRECTION

ksi

ft,allow

kips

TOP STRESS, FOR EDGE LIFT MOMENT, AT B DIRECTION

5.5 BOTTOM STRESS, FOR EDGE LIFT MOMENT, AT L DIRECTION

Then

342.44

ft,allow

f = Pr / A - MB / Sb - Pr e / Sb =

fc,allow

0.189

>
<

Then

ksi

ft,allow

f= Pr / A + ML / St + Pr e / St =

kips / ft

BOTTOM STRESS, FOR CENTER LIFT MOMENT, AT B DIRECTION

5.4 TOP STRESS, FOR EDGE LIFT MOMENT, AT L DIRECTION

Then

372.71

f = Pr / A + MB / Sb - Pr e / Sb =

fc,allow

-0.077

>
<

Then

ksi

ft,allow

f = Pr / A - ML / Sb - Pr e / Sb =

ksi

SG = W slab / 2000 =

kips

5.3 BOTTOM STRESS, FOR CENTER LIFT MOMENT, AT L DIRECTION


f = Pr / A + ML / Sb - Pr e / Sb =

-0.095

Pr = Pe - SG =

kips

SG = Wslab / 2000 =

Then

TOP STRESS, FOR CENTER LIFT MOMENT, AT B DIRECTION

>
<

Then

0.209

ksi

ft,allow

[Satisfactory]

fc,allow

[Satisfactory]

6. CHECK MINIMUM FOUNDATION STIFFNESS (Sec. 6.10)


6.1 RELATIVE STIFFNESS LENGTH AT L DIRECTION
= (Ecr I / Es)1/4 / 12 =

6.323
1.5

Where

Ecr = (0.5) 33 w

(fc')

0.5

RELATIVE STIFFNESS LENGTH AT B DIRECTION


= (Ecr I / Es)1/4 / 12 =

ft
=

1660280

Es =

1000

psi

w =

150

pcf

psi

Es =

6.2 CHECK MINIMUM FOUNDATION STIFFNESS AT L DIRECTION

1660280

1000

psi

psi

FOR CENTER LIFT

12000 ML B C zL / Ecr =

in

6660

360

zL = min(L , 6) =

<

IL

[Satisfactory]

37.94

IL =

19969

ft
in4

11060

in4

12000 MB L C zB / Ecr =

7741

360

Where

zB = min(B , 6) =

in4

<

IB

[Satisfactory]

24.00

IB =

FOR EDGE LIFT

33706

ft
in4

13082

in4

FOR EDGE LIFT

12000 ML B C zL / Ecr =
Where

ft

CHECK MINIMUM FOUNDATION STIFFNESS AT B DIRECTION

FOR CENTER LIFT


Where

7.208

Ecr = (0.5) 33 w1.5 (fc')0.5 =

Where

720

<

IL

12000 MB L C zB / Ecr =

[Satisfactory]

Where

<

720

IB

[Satisfactory]

7. CHECK SHEAR CAPACITY (Sec. 6.11)


7.1 APPLIED SERVICE LOAD SHEAR AT L DIRECTION

APPLIED SERVICE LOAD SHEAR AT B DIRECTION

FOR CENTER LIFT


VL = L

0.09

0.71

SB

0.45

FOR CENTER LIFT


0.44

0.16

ym

0.93

em

/ 1940 =

1.260

VB = B0.19 SL0.45 h0.20 P0.54 ym0.04 em0.97 / 1350 =

kips/ft

FOR EDGE LIFT


VL = L

0.07

0.4

0.03

1.836

kips/ft

1.101

kips/ft

>

50 psi

FOR EDGE LIFT


0.67

ym

0.16

em

0.015

/ (3.0 SB

) =

1.145

0.07

kips/ft

VB = B

7.2 ALLOWABLE CONCRETE SHEAR STRESS, AT L DIRECTION


vc = 2.4 (fc')0.5 + 0.2 fp =

0.155

ksi

Where

0.119

ksi

fp =

0.4

0.03

0.67

ym

0.16

em

0.015

/ (3.0 SL

) =

ALLOWABLE CONCRETE SHEAR STRESS, AT B DIRECTION

>

50 psi

vc = 2.4 (fc')0.5 + 0.2 fp =

0.157

ksi

Where

0.129

ksi

fp =

[Satisfactory]

[Satisfactory]

7.3 SHEAR STRESS OF RIBBED FOUNDATION, AT L DIRECTION

SHEAR STRESS OF RIBBED FOUNDATION, AT B DIRECTION

FOR CENTER LIFT

FOR CENTER LIFT

v = V B / (n h b) =

0.058

<

ksi

vc

v = V L / (n h b) =

0.089

<

ksi

[Satisfactory]

vc

[Satisfactory]

FOR EDGE LIFT

FOR EDGE LIFT

v = V B / (n h b) =

0.053

<

ksi

vc

v = V L / (n h b) =

0.053

<

ksi

[Satisfactory]

vc

[Satisfactory]

8. CHECK SOIL BEARING (Sec. 4.5)


8.1 APPLIED LOADING
SLAB WEIGHT

150 L B t

50400

lbs

RIB BEARING AREA (Sec. 4.5.2.3)

ADDED DL

DL L B

15120

lbs

SOIL PRESSURE

LIVE LOAD

LL L B

40320

lbs

<

BEAM WEIGHT

150 (h-t) b (Total Length)

30319

lbs

[Satisfactory]

PERIMETER LOAD

P (2L + 2B)

91740

lbs

q = Total Load / THE AREA =

811.44
281

ft2
psf
qallow

9. CHECK SLAB STRESS DUE TO LOAD-BEARING PARTITIONS (Sec. 6.14)


9.1 RELATIVE STIFFNESS LENGTH AT L DIRECTION
Mmax = Pb / 4 =
Where

8.10

RELATIVE STIFFNESS LENGTH AT B DIRECTION

= MIN[(Ec t3 / 3 ks)0.25, SB] =

ks =

lb / in3

9.2 TENSILE STRESS AT L DIRECTION


f = Pr / A - Mmax / 2 t2 =

12

ft

Where

8.10

ft-kips / ft

= MIN[(Ec t3 / 3 ks)0.25, SL] =

ks =

lb / in3

TENSILE STRESS AT B DIRECTION


-0.134

>

Mmax = Pb / 4 =

ft-kips / ft

ft,allow

ksi
[Satisfactory]

f = Pr / A - Mmax / 2 t2 =

>

-0.124
ft,allow

ksi
[Satisfactory]

12

ft

(cont'd)

10. CHECK CRACKED SECTION CAPACITY (Sec. 4.5.7 & 6.12)

[Satisfactory]

10.1 CHECK CRACKED SECTION CAPACITY AT L DIRECTION

CHECK CRACKED SECTION CAPACITY AT B DIRECTION

FOR CENTER LIFT

FOR CENTER LIFT

Mcr = F (h - 2" - 0.5a) =

130.6

ft-kips

Where

133.11

kips

F=
a = F / 0.85 fc' b =

1.45

in

60.7

ft-kips, total

Mcr = F (h - 3" - 0.5a) =

76.2

ft-kips

Where

79.87

kips

0.9 ML =

>

0.9 ML

[Satisfactory]

a = F / 0.85 fc' b =
0.9 ML =

233.9

ft-kips

239.60

kips

0.9 MB =

0.11

in

50.4

ft-kips, total

0.9 ML

Where

[Satisfactory]

127.0

ft-kips

Where

133.11

kips

N/A

(Does not apply for beam tendons)

7.77E-03
Eps =

in
ft-kips, total

Mcr = F (h - 3" - 0.5a) =

12. SUGGEST RATIO OF EXPECTED ELONGATION


r = fe / 0.8 Eps =

1.57
111.6

>

0.9 MB

[Satisfactory]

FOR EDGE LIFT

>

11. CONVERT UNIFORM THICKNESS (Sec. 6.12)


H= MAX[ ( I / L)1/3, ( I / B)1/3 ] =

F=
a = F / 0.85 fc' b =

FOR EDGE LIFT


F=

Mcr = F (h - 2" - 0.5a) =


Where

28000

ksi

Technical References:
1. "Design of Post-Tensioned Slab-on-Ground, Third Edition", Post-Tensioning Institute, 2004.
2. "Addendum No.1 to The 3RD Edition of Design of Post-Tensioned Slab-on-Ground", Post-Tensioning Institute, May 2007.
3. "Addendum No.2 to The 3RD Edition of Design of Post-Tensioned Slab-on-Ground", Post-Tensioning Institute, May 2008.

F=
a = F / 0.85 fc' b =
0.9 MB =

0.10

in

94.3

ft-kips, total

>
[Satisfactory]

0.9 MB

PROJECT :

PAGE :

CLIENT :
JOB NO. :

DESIGN BY :
REVIEW BY :

DATE :

Design of PT Slabs on Compressible Soil Ground Based on Standards of PTI 2nd Edition
1. INPUT DATA & DESIGN SUMMARY
1.1 SOILS PROPERTIES
qallow

ALLOWABLE SOIL-BEARING PRESSURE

EXPECTED SETTLEMENT BY GEOTECHNICAL ENR


SLAB-SUBGRADE FRICTION COEFFICIENT

=
=
=

1500

psf

0.75

in

=
=
=
=
=
=
=
=
=
=
=
=

40

0.75

1.2 STRUCTURAL DATA AND MATERIALS PROPERTIES


SLAB LENGTH

SLAB WIDTH

SLAB THICKNESS

PERIMETER LOADING

MAX BEARING LOADING ON THE SLAB

Pb

ADDED DEAD LOAD

DL

LIVE LOAD

LL

AVERAGE STIFFENING BEAM SPACING, L DIRECTION

SL

AVERAGE STIFFENING BEAM SPACING, B DIRECTION

SB

STIFFENING BEAM DEPTH

STIFFENING BEAM WIDTH

b
f'c

CONCRETE STRENGTH

ft

38

ft

in

840

plf

2700

plf

15

psf

40

psf

13.333

ft

12.667

ft

24

in

10

in

ksi

SLAB PRESTRESSING TENDONS, L DIRECTION

tendons w/

0.153

in2 at each tendon.

THE DESIGN IS ADEQUATE.

SLAB PRESTRESSING TENDONS, B DIRECTION

tendons w/

0.153

in2 at each tendon.

SUGGESTED RATIO OF EXPECTED ELONGATION IS 0.00777

TENDON IN THE BOTTOM OF EACH BEAM


EFFECTIVE PRESTRESS AFTER ALL LOSSES EXCEPT SG

tendons w/

in

174

ksi

fe

CONVERTED UNIFORM THICKNESS IS 14.22 inch

2. DETERMINE SECTION PROPERTIES


L DIRECTION

B DIRECTION
yb

18.34

in

yb

18.47

in

in2

St

19294

in3

2720

in2

St

19992

in3

109177

in4

Sb

5952

in3

110544

in4

Sb

5985

in3

22.00

in

3.66

in

CGS

22.00

in

3.53

in

McsS = McsL (970-h) / 880 =

3.44

ft-kips / ft

nsL = L1.28 SB0.80 / 133 h0.28 P0.62 =

0.04

2624

CGS

3. CALCULATE MAXIMUM APPLIED SERVICE MOMENTS


L DIRECTION

B DIRECTION

McsL = ( / nsL)0.5 MnsL =


Where

3.20

ft-kips / ft

MnsL = h1.35 SB0.36 / 80 L0.12 P0.10 =

0.75

nsL = L1.28 SB0.80 / 133 h0.28 P0.62 =

0.04

ft-kips / ft

4. CHECK FLEXURAL CONCRETE STRESSES


4.1 ALLOWABLE CONCRETE STRESSES
FLEXURAL TENSILE STRESS

ft,allow = - 6 (fc')0.5 =

-0.329

ksi

FLEXURAL COMPRESSIVE STRESS

fc,allow = - 0.45 fc' =

1.350

ksi

4.2 TOP STRESS, FOR CENTER LIFT MOMENT, AT L DIRECTION


f = Pr / A + ML / St + Pr e / St =

0.168

Pr = Pe - SG =

Where

Pe = fe Aps =

>
<

f = Pr / A + MB / St + Pr e / St =
161.14

213

kips

Pe = fe Aps =
51.83

ft,allow

[Satisfactory]

fc,allow

[Satisfactory]

f = Pr / A - ML / Sb - Pr e / Sb =

Then

>
<

-0.283

Then

>
<

f = Pr / A - MB / Sb - Pr e / Sb =

[Satisfactory]

fc,allow

[Satisfactory]

213

kips

161.14

51.83

ft,allow

[Satisfactory]

fc,allow

[Satisfactory]

kips

kips

BOTTOM STRESS, FOR CENTER LIFT MOMENT, AT B DIRECTION

ksi

ft,allow

ksi

SG = W slab / 2000 =

kips

4.3 BOTTOM STRESS, FOR CENTER LIFT MOMENT, AT L DIRECTION

0.170

Pr = Pe - SG =

Where

kips

SG = W slab / 2000 =

Then

TOP STRESS, FOR CENTER LIFT MOMENT, AT B DIRECTION

ksi

Then

>
<

-0.312

ksi

ft,allow

[Satisfactory]

fc,allow

[Satisfactory]

5. CHECK DIFFERENTIAL DEFLECTIONS


5.1 RELATIVE STIFFNESS LENGTH AT L DIRECTION
= (Ec I nsL / Es )1/4 / 12 =
Where

4.666
1.5

Ecr = (0.5) 33 w
Es =

0.5

(fc')

RELATIVE STIFFNESS LENGTH AT B DIRECTION


= (Ec I nsB / Es )1/4 / 12 =

ft
=

1000

1660280

I =

I =

109177

in4

150

pcf

1920

cs = en0{1.78 - 0.103 h -1.65E-03 P + 3.95E-07 P P) =

0.12

<
[Satisfactory]

ft

1000

psi

110544

in4

1660280

psi

0.12

in

ALLOWABLE DIFFERENTIAL DEFLECTION AT B DIRECTION


allow = 12 MIN(B, 6) / C =
0.17
in

__
Where

5.3 DIFFERENTIAL DEFLECTION WITHOUT PRESTRESSING

4.652

Ecr = (0.5) 33 w1.5 (fc')0.5 =


Es =

w =

Where

psi

5.2 ALLOWABLE DIFFERENTIAL DEFLECTION AT L DIRECTION


allow = 12 MIN(L, 6) / C =
0.17
in
Where

psi

1920

DIFFERENTIAL DEFLECTION WITHOUT PRESTRESSING


cs = en0{1.78 - 0.103 h -1.65E-03 P + 3.95E-07 P P) =

in

allow

Page 76 of 533
524

<
[Satisfactory]

allow

6. CHECK SHEAR CAPACITY


6.1 APPLIED SERVICE LOAD SHEAR AT L DIRECTION
VcsL = ( / nsL)0.30 VnsL =
Where

0.850

APPLIED SERVICE LOAD SHEAR AT B DIRECTION

kips/ft

VcsS = VcsL (116-h) / 94 =

VnsL = h0.90 (PSB)0.30 / 550 L0.10 =

0.355

6.2 ALLOWABLE CONCRETE SHEAR STRESS, AT L DIRECTION


v c = 2.4 (fc')0.5 + 0.2 fp =
fp =

Where

0.144

ksi

0.061

ksi

0.832

ALLOWABLE CONCRETE SHEAR STRESS, AT B DIRECTION

>

50 psi

v c = 2.4 (fc')0.5 + 0.2 fp =

0.143

ksi

fp =

0.059

ksi

Where

[Satisfactory]

0.034

>

50 psi

[Satisfactory]

6.3 SHEAR STRESS OF RIBBED FOUNDATION, AT L DIRECTION


v = V B / (n h b) =

kips/ft

kips/ft

SHEAR STRESS OF RIBBED FOUNDATION, AT B DIRECTION

<

ksi

vc

v = V L / (n h b) =

0.035

ksi

[Satisfactory]

<

vc

[Satisfactory]

7. CHECK SOIL BEARING


7.1 APPLIED LOADING
SLAB WEIGHT

150 L B t

76000

lbs

BEAM BEARING AREA

ADDED DL

DL L B

22800

lbs

SOIL PRESSURE

(b)(Total Length) =

249

q = Total Load / THE AREA =

1418

LIVE LOAD

LL L B

60800

lbs

<

BEAM WEIGHT

150 (h-t) b (Total Length)

62222

lbs

[Satisfactory]

PERIMETER LOAD

P (2L + 2B)

131040

lbs

ft2
psf
qallow

8. CHECK SLAB STRESS DUE TO LOAD-BEARING PARTITIONS


8.1 RELATIVE STIFFNESS LENGTH AT L DIRECTION
Mmax = Pb / 4 =
Where

8.55

RELATIVE STIFFNESS LENGTH AT B DIRECTION

= MIN[(Ec h3 / 3 ks)0.25, SB] =

ks =

Mmax = Pb / 4 =

ft-kips / ft

lb / in

12.667

ft

Where

ft,allow

>

[Satisfactory]

14.22

in

10. SUGGEST RATIO OF EXPECTED ELONGATION


r = fe / 0.8 Eps =
Where

7.77E-03
Eps =

f = Pr / A - Mmax / 2 t2 =

ksi

9. CONVERT UNIFORM THICKNESS


H= MAX[ ( I / L)1/3, ( I / B)1/3 ] =

ft-kips / ft
lb / in3

TENSILE STRESS AT B DIRECTION


-0.206

>

9.00

= MIN[(Ec h3 / 3 ks)0.25, SB] =

ks =

8.2 TENSILE STRESS AT L DIRECTION


f = Pr / A - Mmax / 2 t2 =

28000

ksi

Technical References:
1. "Design of Post-Tensioned Slab-on-Ground, Second Edition", Post-Tensioning Institute, 1996.
2. "1997 Uniform Building Code, Volume 2, Chapter 18", International Conference of Building Officials, 1997.

__
Page 77 of 533
524

-0.206
ft,allow

ksi
[Satisfactory]

13.333

ft

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Concrete Pier (Isolated Deep Foundation) Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc'

ksi

VERT. REBAR YIELD STRESS


PIER DIAMETER
PIER LENGTH

fy
D
L

=
=
=

60
24
10

ksi
in
ft

FACTORED AXIAL LOAD

Pu

100

FACTORED MOMENT LOAD

Mu

200

ft-k

Vu =
FACTORED SHEAR LOAD
20 k
PIER VERT. REINF.
8
#
7
SEISMIC DESIGN (ACI 21.12.4) ?
Yes
LATERAL REINF. OPTION (0=Spirals, 1=Ties)
1
Ties
LATERAL REINFORCEMENT
#
4 @
6
in o.c.
(spacing 3.0 in o.c. at top end of 10.0 ft.)
(IBC 09 1810.3.9 & ACI 21.12.4)

THE PIER DESIGN IS ADEQUATE.

ANALYSIS
CHECK PIER LIMITATIONS
fc' =
D=

>

ksi

24

[Satisfactory]
>
in
[Satisfactory]

2.5

ksi

(IBC 09 Table 1808.8.1)


MAX( L / 12 , 24 in)
(IBC 09 1810.2.2)

CHECK FLEXURAL & AXIAL CAPACITY

o =

Pmax =F [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

=
=

Ag =

'
C

2 0.85 f

, E c = 57

Ec
0.85 f

'
C

0.85 f

'
C

sEs ,
f y ,

c c
o
o

2
452 in .

Ast =

600

400

200

>
4.80

100

-400

Mn (ft-k)

150

for 0 < c < o

Pu

200

250

[Satisfactory]

in2.
Pn (kips)
743
743
639
527
432
288

Mn (ft-kips)
0
108
161
198
215
222

282
96

224
234

AT FLEXURE ONLY

174

AT TENSION ONLY

-259

AT BALANCED CONDITION
AT t = 0.005

0
50

for s > y

AT COMPRESSION ONLY
AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT t = 0.002

743.26 kips., (at max axial load, ACI 318-08, Sec. 10.3.6.2)

0.8 , ACI 318-08, Sec. 10.3.6.1 or 10.3.6.2


0.65 (ACI 318-08, Sec.9.3.2.2)

-200

, E s = 29000ksi

'
C

for c o
for s y

800

Pn (k)

(cont'd)
a = Cb 1 =

10

in (at balanced strain condition, ACI 10.3.2)

0.75 + ( t - 0.002 ) (50), for Spiral

0.65 + ( t - 0.002 ) (250 / 3), for Ties


where

Cb = d c / ( c + s) =
d

in

20.1 in, (ACI 7.7.1)

Mn = 0.9 n =

174

Mn =

ft-kips @ Pu =

234

12

0.656

(ACI 318-08, Fig. R9.3.2)

t =

0.002069

1 =

0.85

ft-kips @ Pn = 0, (ACI 318-08, Sec. 9.3.2) ,&


100

max

0.08 (ACI 318-08, Section 10.9)

min

0.005 (IBC 09, 1810.3.9.4.2)

provd

0.003

( ACI 318-08, Sec. 10.2.7.3 )

t,max = 0.004, (ACI 318-08, Sec. 10.3.5)

>

kips

c =

Mu

[Satisfactory]

0.011
[Satisfactory]

CHECK SHEAR CAPACITY

Vn = (Vs + Vc) =

86

kips, (ACI 318-08 Sec. 11.1.1)

>

where

=
A0 =

smax
smin
s =

Vu
[Satisfactory]
0.75 (ACI 318-08 Sec. 9.3.2.3)
2
316 in .

Av =

0.5

Vc =

2 (fc') A0 =

Vs =

MIN (d fy Av / s , 8 (fc')0.5A0) =

10.5 (IBC 09 1810.3.9.4.2)

34.6

0.40

in2.

fy =

ksi

kips, (ACI 318-08 Sec. 11.2.1, 11.2.1.3)


80.3

kips, (ACI 318-08 Sec. 11.4.7.2 & 11.4.7.9)


sprovd

0.12 fc' / fyt = 0.006

60

in
[Satisfactory]

<

s,provd =

0.008 [Satisfactory]

(ACI 318-08 Sec. 21.12.4.4 & 21.6.4.1)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Drilled Cast-in-place Pile Design Based on ACI 318-08


DESIGN CRITERIA
1.

ASSUME FIX HEAD CONDITION IF Ldh & Lhk COMPLY WITH THE TENSION DEVELOPMENT. OTHERWISE PINNED AT TOP.

2.

FROM PILE CAP BALANCED LOADS & REACTIONS, DETERMINE MAX SECTION FORCES OF SINGLE PILE, Pu, Mu, & Vu.

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

fc'

ksi

VERT. REBAR YIELD STRESS


PILE DIAMETER
PILE LENGTH

fy
D
L

=
=
=

60
24
35

ksi
in
ft

FACTORED AXIAL LOAD

Pu

100

FACTORED MOMENT LOAD

Mu

200

ft-k

Vu =
FACTORED SHEAR LOAD
20 k
PILE VERT. REINF.
8
#
7
SEISMIC DESIGN (ACI 21.12.4) ?
Yes
LATERAL REINF. OPTION (0=Spirals, 1=Ties)
1
Ties
LATERAL REINFORCEMENT
#
4 @
6
in o.c.
(spacing 3.0 in o.c. at top end of 10.0 ft.)
(IBC 09 1810.3.9 & ACI 21.12.4)
( L dh =

in

L hk =

&

14

in )

THE PILE DESIGN IS ADEQUATE.

ANALYSIS
CHECK PILE LIMITATIONS
fc' =

ksi

D=

24

in

>
>

ksi

[Satisfactory]

(IBC 09 Table 1808.8.1)

MAX( L / 30 , 12 in) [Satisfactory]

(IBC 09 1810.3.5.2)

CHECK FLEXURAL & AXIAL CAPACITY

o =

Pmax =F [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

F
=

=
Ag =

'
C

2 0.85 f

Ec

, E c = 57

, E s = 29000ksi

'
C

0.85 f

'
C

c c
o
o

0.85 f

'
C

for c o

for 0 < c < o

s E s , for s y
f y ,

for s > y

941.1 kips., (at max axial load, ACI 318-08, Sec. 10.3.6.2)

0.8 , ACI 318-08, Sec. 10.3.6.1 or 10.3.6.2


0.65 (ACI 318-08, Sec.9.3.2.2)
2
Ast =
452 in .

4.80

in2.

>

Pu

[Satisfactory]

(cont'd)
1200

Pn (kips)
941
941
789
651
536
367

Mn (ft-kips)
0
132
208
250
267
270

360
153

272
279

AT FLEXURE ONLY

183

AT TENSION ONLY

-259

1000

AT COMPRESSION ONLY
AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT t = 0.002

800
600

Pn (k)

400
200

AT BALANCED CONDITION
AT t = 0.005

0
0

50

100

150

200

250

300

-200
-400

Mn (ft-k)
a = Cb 1 =

10

in (at balanced strain condition, ACI 10.3.2)

0.75 + ( t - 0.002 ) (50), for Spiral

0.65 + ( t - 0.002 ) (250 / 3), for Ties

Cb = d c / ( c + s) =

where

in

20.1 in, (ACI 7.7.1)

Mn = 0.9 n =

183

Mn =

ft-kips @ Pu =

246

12

0.656

(ACI 318-08, Fig. R9.3.2)

t =

0.002069

1 =

0.85

c =

0.003

( ACI 318-08, Sec. 10.2.7.3 )

ft-kips @ Pn = 0, (ACI 318-08, Sec. 9.3.2) ,& et,max = 0.004, (ACI 318-08, Sec. 10.3.5)
100

>

kips

max

0.08 (ACI 318-08, Section 10.9)

min

0.005 (IBC 09 1810.3.9.4.2)

provd

Mu

[Satisfactory]

0.011
[Satisfactory]

CHECK SHEAR CAPACITY

Vn = (Vs + Vc) =

90

kips, (ACI 318-08 Sec. 11.1.1)

>

where

smax
smin
s =

Vu
[Satisfactory]
0.75 (ACI 318-08 Sec. 9.3.2.3)

A0 =

2
316 in .

Vc =

2 (fc')0.5A0 =

Vs =

MIN (d fy Av / s , 8 (fc')0.5A0) =

10.5 (IBC 09 1810.3.9.4.2)

Av =
40.0

0.40

in2.

fy =

80.3

sprovd

s,provd =

where

requird 0.02 ed b f y
, 8d b , 6 in =
provided f 'c

14
db

required / provided
e

=
=
=

in
[Satisfactory]

<

0.008 [Satisfactory]

(ACI 318-08 Sec. 21.12.4.4 & 21.6.4.1)

DETERMINE FIX HEAD CONDITION

L hk

ksi

kips, (ACI 318-08 Sec. 11.4.7.2 & 11.4.7.9)

0.12 fc' / fyt = 0.008

L dh = MAX

60

kips, (ACI 318-08 Sec. 11.2.1, 11.2.1.3)

=
11 db
9
in
(ACI 318-08 12.5.2)

in, (ACI 318-08, Fig. R12.5)


0.88 in
=

0.8

( A s,reqd / A s,provd , ACI 318, 12.2.5)

1.0 (1.2 for epoxy-coated, ACI 318-08 12.2.4)


1.0 (normal weight)
0.7 (#11 or smaller, cover > 2.5" & side >2.0",
ACI 318-08 12.5.3)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Pile Cap Design for 3-Piles Pattern Based on ACI 318-08


DESIGN CRITERIA
1.

FROM PILE DESIGN & SOIL REPORT, DETERMINE SINGLE PILE MAX LOADS OR CAPACITY AT CAP BOTTOM FACE, Pn, Mn, & Vn.

2.

THE MAXIMUM COLUMN CAPACITY AT COLUMN BASE, Pn,col, Mn,col, Vn,col, MAY BE BASED ON PILE CAP BALANCED LOADS.

3.

PILE CAPS SHALL BE INTERCONNECTED BY TIES WITH Min(0.25, SDS/10) TIMES AXIAL VERT COLUMN LOADING. (IBC 09 1810.3.13)

USER CAN CHANGE THE YELLOW CELLS TO MODIFY THEM FOR DIFFERENT CASES.

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

fc'

ksi

REBAR YIELD STRESS


PILE DIAMETER
COLUMN SIZE (SHORT SIDE)

fy
D
C

=
=
=

60
20
24

ksi
in
in

SINGLE PILE MAX LOADS OR CAPACITY

Pn

130

(at the section of cap bottom face)

Mn

400

ft-k

PILE CLEAR DIST. (24" min, 2D reqd)


EDGE DISTANCE (9" min)

Vn =
Clear =
Edge =

35
40
12

k
in
in

EFFECTIVE DEPTH
CAP BOTTOM REINFORCING

The Column Can Support Max Loads:

53

in

16

in o.c., each way

Pu,col

Pn,col =

390

Mu,col

Mn,col =

710.0

Vu,col

Vn,col =

105

kips
ft-kips
kips

THE PILE CAP DESIGN IS ADEQUATE.

ANALYSIS
CHECK FLEXURE CAPACITY AT COLUMN FACE (ACI 318-08, 10.2, 10.3, 10.5, 7.12.2)
Pile Spacing =
Cap Edge Length =
L1-1 =
77.0
L2-2 =
104.7
Mu, 1-1 =
113.4
Mu, 2-2 =
123.7
provD =
0.0012
0.85 f c 1 1
'

MAX =

60
in
136.2
in
in, length of section 1-1
in, length of section 2-2
ft-kips / ft, (to middle of cap elevation)
ft-kips / ft, (to middle of cap elevation)

M u, max
'
0.383bd 2 f c

fy

0.85 1 f 'c
fy

u
=
u + t

MIN = MIN 0.0018

T
4
,
=
d
3

0.0008

< provD

[Satisfactory]

0.0206

> provD

[Satisfactory]

0.0011

< provD

[Satisfactory]

CHECK ONE WAY SHEAR CAPACITY AT THE FACE OF COLUMN & PILE
L3-3 =
62.4
Vu, 2-2 = 2 (Pn) / L2-2 =

(ACI 318-08, Chapter 11, Except 11.1.3.1)


in, length of section 3-3
kips / ft
0.0
(No shear at "d" offset.)
0.0

kips / ft

60.3

kips / ft

Vu, 3-3 = (Pn) / L3-3 =


Vc = 2 b d (fc')0.5 =
where

(No shear at "d" offset.)

> Vu, max

[Satisfactory]

0.75 (ACI 318-08, Section 9.3.2.3 )

CHECK COLUMN PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)
v c( psi) = ( 2 + y ) f 'c = 190 ksi
where

0.5 v M u ,col b1

__
>

vu ( psi ) =

P u,col
AP

v = 1

c =

1.00

b1 =

(C + d) =

b2 =

(C + d) =

b0 =

2b1 + 2b2 =

Ap =

b0 d

77

in

77

in

308

16324

in

in2

J=

Page 82 of 533
524

d b13
6

2
1+
3

1+

b1
b2

d
b1

+3

31

ksi

y = MIN 2,

0.4

b2
b1

[Satisfactory]

870

ft4

, 40

d
b0

2.0

(cont'd)

CHECK SINGLE PILE PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)

v c ( psi) = ( 2 + y ) f 'c =
where

95

vu ( psi ) =

>

ksi

P u,col
AP

0.5 v M u ,col b1

=
b1 =

134.1 deg
( / 360) (D / 4 + d) =

26 in

b2 =

( / 360) (D / 4 + d) =

26 in

b0 =

( / 360) (D + d) =

85 in, conservative value

b0 d

in

Ap =
J=

d b13

v = 1

y=

1+

=
d
b1

1
2
1+
3

+3

=
b1
b2

4529
b2
b1

59

ft

0.4

, conservative value as one way shear

__
Page 83 of 533
524

49

ksi

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Pile Cap Design for 4-Piles Pattern Based on ACI 318-08


DESIGN CRITERIA
1.

FROM PILE DESIGN & SOIL REPORT, DETERMINE SINGLE PILE MAX LOADS OR CAPACITY AT CAP BOTTOM FACE, Pn, Mn, & Vn.

2.

THE MAXIMUM COLUMN CAPACITY AT COLUMN BASE, Pn,col, Mn,col, Vn,col, MAY BE BASED ON PILE CAP BALANCED LOADS.

3.

PILE CAPS SHALL BE INTERCONNECTED BY TIES WITH Min(0.25, SDS/10) TIMES AXIAL VERT COLUMN LOADING. (IBC 09 1810.3.13)

USER CAN CHANGE THE YELLOW CELLS TO MODIFY THEM FOR DIFFERENT CASES.

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

fc'

ksi

REBAR YIELD STRESS


PILE DIAMETER
COLUMN SIZE (SHORT SIDE)

fy
D
C

=
=
=

60
20
24

ksi
in
in

SINGLE PILE MAX LOADS OR CAPACITY

Pn

130

(at the section of cap bottom face)

Mn

400

ft-k

PILE CLEAR DIST. (24" min, 2D reqd)


EDGE DISTANCE (9" min)

Vn =
Clear =
Edge =

35
40
12

k
in
in

EFFECTIVE DEPTH
CAP BOTTOM REINFORCING

The Column Can Support Max Loads:

53

in

12

in o.c., each way

Pu,col

Pn,col =

520

Mu,col

Mn,col =

946.7

Vu,col

Vn,col =

140

kips
ft-kips
kips

THE PILE CAP DESIGN IS ADEQUATE.

ANALYSIS
CHECK FLEXURE CAPACITY AT COLUMN FACE (ACI 318-08, 10.2, 10.3, 10.5, 7.12.2)
Pile Spacing =
Cap Edge Length =
L1-1 =
113.1
L2-2 =
104.0
Mu, 1-1 =
80.3
Mu, 2-2 =
156.2
provD =
0.0016
0.85 f c 1 1
'

MAX =

60
in
104.0
in
in, length of section 1-1
in, length of section 2-2
ft-kips / ft, (to middle of cap elevation)
ft-kips / ft, (to middle of cap elevation)

M u, max
'
0.383bd 2 f c

fy

0.85 1 f 'c
fy

u
=
u + t

MIN = MIN 0.0018

T
4
,
=
d
3

0.0010

< provD

[Satisfactory]

0.0206

> provD

[Satisfactory]

0.0014

< provD

[Satisfactory]

CHECK ONE WAY SHEAR CAPACITY AT THE FACE OF COLUMN & PILE
L3-3 =
82.2
Vu, 2-2 = 2 (Pn) / L2-2 =

(ACI 318-08, Chapter 11, Except 11.1.3.1)


in, length of section 3-3
kips / ft
0.0
(No shear at "d" offset.)
0.0

kips / ft

60.3

kips / ft

Vu, 3-3 = (Pn) / L3-3 =


Vc = 2 b d (fc')0.5 =
where

(No shear at "d" offset.)

> Vu, max

[Satisfactory]

0.75 (ACI 318-08, Section 9.3.2.3 )

CHECK COLUMN PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)
v c( psi) = ( 2 + y ) f 'c = 190 ksi
where

0.5 v M u ,col b1

__
>

vu ( psi ) =

P u,col
AP

v = 1

c =

1.00

b1 =

(C + d) =

b2 =

(C + d) =

b0 =

2b1 + 2b2 =

Ap =

b0 d

77

in

77

in

308

16324

in

in2

J=

Page 84 of 533
524

d b13
6

2
1+
3

1+

b1
b2

d
b1

+3

42

ksi

y = MIN 2,

0.4

b2
b1

[Satisfactory]

870

ft4

, 40

d
b0

2.0

(cont'd)

CHECK SINGLE PILE PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)

v c ( psi) = ( 2 + y ) f 'c =
where

95

vu ( psi ) =

>

ksi

=
b1 =

164.1 deg
( / 360) (D / 4 + d) =

b2 =

( / 360) (D / 4 + d) =

31 in

b0 =

( / 360) (D + d) =

105

b0 d

in

Ap =
d b13
J=
6

v = 1

y=

1+

=
d
b1

1
2
1+
3

+3

=
b1
b2

5542

b2
b1

P u,col
AP

0.5 v M u ,col b1
J

31 in
in, conservative value

90

ft

0.4

, conservative value as one way shear

__
Page 85 of 533
524

40

ksi

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Pile Cap Design for 2-Piles Pattern Based on ACI 318-08


DESIGN CRITERIA
1.

FROM PILE DESIGN & SOIL REPORT, DETERMINE SINGLE PILE MAX LOADS OR CAPACITY AT CAP BOTTOM FACE, Pn, Mn, & Vn.

2.

THE MAXIMUM COLUMN CAPACITY AT COLUMN BASE, Pn,col, Mn,col, Vn,col, MAY BE BASED ON PILE CAP BALANCED LOADS.

3.

PILE CAPS SHALL BE INTERCONNECTED BY TIES WITH Min(0.25, SDS/10) TIMES AXIAL VERT COLUMN LOADING. (IBC 09 1810.3.13)

USER CAN CHANGE THE YELLOW CELLS TO MODIFY THEM FOR DIFFERENT CASES.

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

fc'

ksi

REBAR YIELD STRESS


PILE DIAMETER
COLUMN SIZE (SHORT SIDE)

fy
D
C

=
=
=

60
20
24

ksi
in
in

SINGLE PILE MAX LOADS OR CAPACITY

Pn

130

(at the section of cap bottom face)

Mn

400

ft-k

PILE CLEAR DIST. (24" min, 2D reqd)


EDGE DISTANCE (9" min)

Vn =
Clear =
Edge =

35
40
12

k
in
in

EFFECTIVE DEPTH
CAP BOTTOM REINFORCING

The Column Can Support Max Loads:

53

in

12

in o.c., each way

Pu,col

Pn,col =

260

Mu,col

Mn,col =

473.3

Vu,col

Vn,col =

70

kips
ft-kips
kips

THE PILE CAP DESIGN IS ADEQUATE.

ANALYSIS
CHECK FLEXURE CAPACITY AT COLUMN FACE (ACI 318-08, 10.2, 10.3, 10.5, 7.12.2)
Pile Spacing =
Cap Edge Length =
L1-1 =
44.0
Mu, 1-1 =
104.4
provD =
0.0016
0.85 f c 1 1
'

MAX =

60
in
104.0
in
in, length of section 1-1
ft-kips / ft, (to middle of cap elevation)

M u, max
'
0.383bd 2 f c

fy

0.85 1 f 'c
fy

u
=
u + t

MIN = MIN 0.0018

T
4
,
=
d
3

0.0007

< provD

[Satisfactory]

0.0206

> provD

[Satisfactory]

0.0009

< provD

[Satisfactory]

CHECK ONE WAY SHEAR CAPACITY AT THE FACE OF COLUMN & PILE
L2-2 =
44.0
Vu, 1-1 = (Pn) / L1-1 =

(ACI 318-08, Chapter 11, Except 11.1.3.1)


in, length of section 2-2
kips / ft
0.0
(No shear at "d" offset.)
0.0

kips / ft

60.3

kips / ft

Vu, 2-2 = (Pn) / L2-2 =


Vc = 2 b d (fc')0.5 =
where

(No shear at "d" offset.)

> Vu, max

[Satisfactory]

0.75 (ACI 318-08, Section 9.3.2.3 )

CHECK COLUMN PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)
v c( psi) = ( 2 + y ) f 'c = 190 ksi
where

>

vu ( psi ) =

P u,col
AP

0.5 v M u ,col b1
J

31

__
v = 1

c =

1.00

b1 =

(C + d) =

b2 =

[(C + min(Edge , d)] =

b0 =

2b1 + 2b2 =

Ap =

b0 d

77

226

11978

in

36

in

in

in2

2
1+
3

J=

Page 86 of 533
524

d b13
6

1+

b1
b2

d
b1

+3

ksi

0.4937

b2
b1

[Satisfactory]
y = MIN 2,

559

ft4

, 40

d
b0

2.0

(cont'd)

CHECK SINGLE PILE PUNCHING CAPACITY (ACI 318-08, 11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)

v c ( psi) = ( 2 + y ) f 'c =
where

95

vu ( psi ) =

>

ksi

P u,col
AP

0.5 v M u ,col b1

=
b1 =

94.3 deg
( / 360) (D / 4 + d) =

18 in

b2 =

( / 360) (D / 4 + d) =

18 in

b0 =

( / 360) (D + d) =

60 in, conservative value

b0 d

in

Ap =
J=

d b13

v = 1

y=

1+

=
d
b1

1
2
1+
3

+3

=
b1
b2

3185
b2
b1

31

ft

0.4

, conservative value as one way shear

__
Page 87 of 533
524

67

ksi

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Determination of Pile Cap Balanced Loads and Reactions


DESIGN CRITERIA
1.

2.

PILE TOP SHEAR, RV, & MOMENT, RM, RELATIONSHIP


MUST BE FROM SOIL REPORT (RV vs RM) DIAGRAM.
THEY ARE NON-LINEAR SET AND EQUAL AT ALL TOP
OF PILES FOR RIGID PILE CAP. USING LINEAR
SPRINGS TO MODEL THEM IS INADEQUATE.
PILE CAPS SHALL BE INTERCONNECTED BY TIES
WITH Min(SDS/10, 0.25) TIMES AXIAL VERT
COLUMN LOADING. (IBC 09 1810.3.13). TO CONSIDER
CONCRETE TENSION CREAKED, THE TIE BEAM
SHOULD NOT BE LATERAL REACTION MEMBER.

INPUT DATA & DESIGN SUMMARY


NUMBER OF HORIZONTAL PILE ROWS
NUMBER OF VERTICAL PILE ROWS
PILES STAGGERED ?
PILE DIAMETER
D=
PILE CLEAR DISTANCE
Clear =
EDGE DISTANCE
Edge =
PILE CAP HEIGHT
H=
PASSIVE SOIL PRESSURE
PP =

5
11
Yes
24
48
12
72
300

in
in
in
in
pcf

Center of Cap

PILE LOCATION TO CENTER OF PILE CAP


AND VERTICAL REACTIONS
X (in)
Y (in)
R (kips)
Pile
1
-312
72
-684.1
2
-312
0
-684.1
3
-312
-72
-684.1
4
-249
36
-585.3
5
-249
-36
-585.3
6
-187
72
-486.4
7
-187
0
-486.4
INPUT POINT LOADS ON TOP OF CAP
X (in)
Y (in)
P (k)
Vx (k)
Vy (k)
My (ft-k) Mx (ft-k)
8
-187
-72
-486.4
LOAD
9
-125
36
-387.5
1
-144
0
-8507.55
700
10
-125
-36
-387.5
2
144
0
3192.483
700
11
-62
72
-288.7
3
12
-62
0
-288.7
4
13
-62
-72
-288.7
5
14
0
36
-189.8
6
15
0
-36
-189.8
7
16
62
72
-91.0
8
17
62
0
-91.0
9
18
62
-72
-91.0
10
19
125
36
7.9
20
125
-36
7.9
PILE CAP SIZE
TOTAL LOADS ON PILE CENTER OF CAP BOTTOM FACE
21
187
72
106.8
X=
672
in
P
-5315.1 kips
22

187

106.8

Y=

192

in

Vx =

H=

72

in

My =

23

187

-72

106.8

24

249

36

205.6

25

249

-36

205.6

26

312

72

304.5

27
28

312
312

0
-72

304.5
304.5

RM =

170

kips

148973.1 ft-kips

__
RV = (Vx2 + Vy2)0.5 / No. =

46.9

kips

ft-kips, (from Soil Report per Rv above)

DETERMINE MAXIMUM PILE VERTICAL REACTIONS


2
Ix =
75168 piles-in
A=
28
piles
Rmax =

Group Center

1313.6

304.5 kips

Rmin =

Vy =

0.0

kips

Mx =

0.0

ft-kips

RM,x =

170.0

ft-kips

RM,y =

0.0

ft-kips

Iy =

-684.1 kips, (Tension)

(The Bold Italic Red values are for pile and pile cap design.)

Page 88 of 533
524

1127520 piles-in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Design of Footing at Piping Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
COLUMN WIDTH

c1

in

COLUMN DEPTH

c2

in

BASE PLATE WIDTH

b1

16

in

BASE PLATE DEPTH

b2

16

in

FOOTING CONCRETE STRENGTH

fc'

2.5

ksi

REBAR YIELD STRESS

fy

60

ksi

AXIAL DEAD LOAD

PDL

40

AXIAL LIVE LOAD

PLL

25

LATERAL LOAD (0=WIND, 1=SEISMIC)


PLAT
SEISMIC AXIAL LOAD

=
=

1
20

Seismic,SD
k, SD

SEISMIC MOMENT LOAD

MLAT

96

ft-k, SD

SEISMIC SHEAR LOAD

VLAT

k, SD

SURCHARGE

qs

0.1

ksf

SOIL WEIGHT

ws

0.11

kcf

FOOTING EMBEDMENT DEPTH

Df

ft

FOOTING MIDDLE THICKNESS


SOIL COVER THICKNESS

T
D

=
=

18
12

in
in

Qa

ksf

=
#

7
5

ft

ALLOW SOIL PRESSURE


SQUARE FOOTING LENGTH
REINFORCING SIZE

MIDDLE BOTTOM EACH WAY :

THE FOOTING DESIGN IS ADEQUATE.

9 # 5 @ 9 in o.c.

ANALYSIS
DESIGN LOADS (IBC SEC.1605.3.2 & ACI 318-08 SEC.9.2.1)
CASE 1:
DL + LL
P
=
65
M
=
0
CASE 2:
DL + LL + E / 1.4
P
=
79
M
=
69
CASE 3:
0.9 DL + E / 1.4
P
=
50
M
=
69

kips
ft-kips
kips
ft-kips
kips
ft-kips

CHECK OVERTURNING FACTOR (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
MR / MO =
6.4
>
F = 0.75 / 0.9
[Satisfactory]
Where MO =

MLAT + VLAT Df - 0.5 PLAT L =

32

k-ft

Pconc = (0.15 kcf) L2 [T + 2 (Df - D - T) /3] = 13.48


Psoil =

ws D L2 =

MR =

0.5 PDLL + 0.5 (Pconc + Psoil) L =

5.39

k, footing wt

k, soil weight
206

k-ft

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)


Service Loads
P
qs L2
P conc - soil
P
M
qmin

CASE 1
65.0

CASE 2
79.3

CASE 3
50.3

4.9

4.9

0.0

k, (surcharge load)

3.6
73.5
0.0

3.6
87.8
68.6

3.2
53.5
68.6

k, (footing increased)
k
ft - k

1.441 > 0

0.393 > 0

ksf, net pressure

2.272

1.223

ksf, net pressure

3.102

2.054

ksf, net pressure

3.933

2.884

ksf, net pressure

4.0

4.0

ksf

2.250 > 0

q3

2.250

q2

2.250

qmax

2.250

qallow

3.0

__
Page 89 of 533
524

(cont'd)
Where

q max = 0.5
q min = 0.5

3 P
2

L
3 P
L

162 M

2
1
q 2 = q max + q min
3
3
1
2
q 3 = q max + q min
3
3

13 L
162 M
13L

[Satisfactory]

DESIGN FLEXURE & CHECK FLEXURE SHEAR (ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, 12.5, 15.5.2, 11.1.3.1, & 11.2)

Service Loads
V
M

MAX =

CASE 1
36.7
69.7

0.85 1 f 'c
fy

CASE 2
57.5
111.6

u
u +t

CASE 3
40.3
79.1

0.85 f c 1 1
'

k, flexure shear
ft - k, flexure moment

Mu
0.383b d 2 f c'

MIN = MIN 0.0018

fy

T
4

,
d
3

DESIGN FLEXURE
Location
Mu,max = 1.5 M
Middle Bottom Each Way 167.3 ft-k

d (in)
14.69

min
reqD
max
0.0022 0.0021 0.0129

smax
18

use
9 # 5 @ 9 in o.c.

provD
0.0023
[Satisfactory]

CHECK FLEXURE SHEAR


Vu,max = 1.5 V

Direction
Pipe Direction

86.2

Vc = 2 b d (fc')0.5

93

check Vu < Vc

[Satisfactory]

CHECK PUNCHING SHEAR (ACI 318-08 SEC.15.5.2, 11.11.1.2, 11.11.6, & 13.5.3.2)

P u R 0.5 v M ub1
+
J
AP
2
3
d b1
d
b2
1+
+3
6
b1
b1

A P = 2 ( b1 + b 2 ) d
1
v = 1
2 b1
1+
3 b2
2 2
Af = L
3

vu ( psi ) =
J =
R=0

Case
1
2
3
where

Pu
97.5
118.9
75.4

Mu
0.0
102.9
102.9

Pu
Mu

=
=
=

b1
25.2
25.2
25.2

b2
25.2
25.2
25.2

b0
100.8
100.8
100.8

v
0.4
0.4
0.4

c
1.0
1.0
1.0

v c( psi ) = ( 2 + y )
y = MIN 2,
b0 =

y
2.0
2.0
2.0

, 40

d
b0

AP
, b1 = ( 0.5c1 + 0.5b1 + d ) , b 2 = ( 0.5c 2 + 0.5b 2 + d )
d

Af
32.7
32.7
32.7

0.75 (ACI 318-08, Section 9.3.2.3 )


1.5 Pcol
1.5 Mcol

__
Page 90 of 533
524

'
fc

Ap
10.3
10.3
10.3

R
0.0
0.0
0.0

J
8.2
8.2
8.2

vu (psi)
65.9
117.0
87.6

vc
150.0
150.0
150.0
[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Circular Footing Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
COLUMN DIAMETER

dcol =

12

in

COLUMN DEAD LOAD

PDL =

40

kips

COLUMN LIVE LOAD

PLL =

38

kips

Wind,ASD

WIND AXIAL LOAD

PLAT =

k, ASD

WIND MOMENT LOAD

MLAT =

39.5

ft-k, ASD

WIND SHEAR LOAD

VLAT =

0.15

k, ASD

SOIL WEIGHT

ws =

0.11

kcf

FOOTING EMBEDMENT DEPTH

Df =

ft

LATERAL LOAD (0=Wind, 1=Seismic)

FOOTING THICKNESS

T=

18

in

Qa =

2.5

ksf

FOOTING DIAMETER

D=

7.5

ft

CONCRETE STRENGTH

fc' =

ksi

REBAR YIELD STRESS

fy =

60

ksi

ALLOW SOIL PRESSURE

FOOTING TOP REBAR

48

in o.c., each way

FOOTING BOTTOM REBAR

18

in o.c., each way

THE FOOTING DESIGN IS ADEQUATE.


ANALYSIS
CHECK OVERTURNING FACTOR (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
MR / MO =

9.4

Where MO =

>

F = 1.6 / 0.9 =

1.78

[Satisfactory]

MLAT + VLAT T - PLAT(0.5 D) =

21

Pftg =

(0.15 kcf) T D2/ 4 =

9.94

k, footing weight

Psoil =

ws (Df - T) D2/ 4 =

2.43

k, soil weight

MR =

k-ft

(PDL+ Pftg + Psoil) (0.5 D) =

196

COMBINED LOADS AT TOP FOOTING (IBC 1605.3.2 & ACI 318-08 9.2.1)
CASE 1:
DL + LL
P =
78.0 kips

1.2 DL + 1.6 LL

Pu

108.8 kips

CASE 2:

DL + LL + 1.3 W

1.2 DL + LL + 1.6 W

CASE 3:

DL + LL + 0.65 W

kips
ft-kips
kips
ft, fr cl ftg
kips
ft-kips
kips
ft, fr cl ftg

Pu
Mu
Vu
eu
Pu
Mu
Vu
eu

=
=
=
=
=
=
=
=

94.0
63
0.2
0.7
44.0
63
0.2
1.4

CASE 1
78.0
0.0

CASE 2
84.5
0.6

CASE 3
81.3
0.3

Pftg - Psoil
P
e

7.5
85.5
0.0

7.5
92.0
0.6

6.8
88.0
0.3

qmin
x

1.94

0.83
@ 0.00 ft, from edge

1.37
@ 0.00 ft, from edge

ksf

qmax

1.94

3.33

2.62

ksf

qallowable

2.50

3.33

3.33

ksf

P
M
V
e
P
M
V
e

=
=
=
=
=
=
=
=

84.5
51
0.2
0.6
81.3
26
0.1
0.3

0.9 DL+ 1.6 W

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)


Service Loads
P
e

[Satisfactory]

__

CHECK FLEXURE & SHEAR OF FOOTING


(ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, 12.5, 15.5.2, 11.1.3.1, & 11.2)

MIN = MIN 0.0018

0.85 f c' 1 1

T
4

,
d
3

Mu
0.383b d 2 f 'c

fy

MAX =

0.85 1 f c'
f y

u
u +t

Page 91 of 533
524

k
ft (from center of footing)
k, (footing increasing)
k, (net loads)
ft

k-ft

kips
ft-kips
kips
ft, fr cl ftg
kips
ft-kips
kips
ft, fr cl ftg

(cont'd)
FACTORED SOIL PRESSURE
Factored Loads
CASE 1
Pu

108.8

eu
[0.15T + ws(Df - T)] A
Pu

CASE 2

CASE 3

94.0

44.0

0.0

0.7

1.4

14.8

14.8

11.1

123.6

108.8

55.1

k
ft
k, (factored footing & backfill)
k

eu

0.0

0.6

1.2

ft

qu, min
x

2.80

0.93
@ 0.00 ft, from edge

0.00
@ 0.75 ft, from edge

ksf

2.80

4.00

2.81

ksf

qu, max

FOOTING MOMENT & SHEAR FOR CASE 1


0
1/10 D
Section

2/10 D

3/10 D

4/10 D

Center

6/10 D

7/10 D

8/10 D

9/10 D

Xu (ft, dist. from left of footing)


Tangent (ft)
TA ( ft2 )

0
0.00
0.00

0.75
4.50
2.30

1.50
6.00
3.99

2.25
6.87
4.86

3.00
7.35
5.36

3.75
7.50
11.17

4.50
7.35
5.36

5.25
6.87
4.86

6.00
6.00
3.99

6.75
4.50
2.30

7.50
0.00
0.00

Mu,col (ft-k)

81.6

163.2

244.8

326.4

408
108.8

Vu,col (k)

54.4

108.8

108.8

108.8

108.8

qu,ftg & fill (ksf)

0.34

0.34

0.34

0.34

0.34

0.34

0.34

0.34

0.34

0.34

0.34

Mu,ftg & fill (ft-k)

0.00

0.00

0.58

2.16

4.97

9.13

16.11

24.43

33.98

44.53

55.67

Vu,ftg & fill (k)

0.00

0.39

1.44

2.93

4.65

7.42

10.20

11.91

13.40

14.46

14.84

qu,soil (ksf)

-2.80

-2.80

-2.80

-2.80

-2.80

-2.80

-2.80

-2.80

-2.80

-2.80

-2.80

Mu,soil (ft-k)

-4.8262 -18.029 -41.427 -76.066 -134.16 -203.5 -283.03 -370.93 -463.67

Vu,soil (k)

-3.2175 -12.02 -24.401 -38.691 -61.822 -84.953 -99.243 -111.62 -120.43 -123.64

Mu (ft-k)

-2.1234 -4.2468 -15.865 -36.454 -66.934 -36.454 -15.865 -4.2468 -2.1234

Vu (kips)

-2.8312 -10.577 -21.471 -34.046

FOOTING MOMENT & SHEAR FOR CASE 2


Section
0
1/10 D

34.046 21.471 10.577 2.8312

2/10 D

3/10 D

4/10 D

Center

6/10 D

7/10 D

8/10 D

9/10 D

Xu (ft, dist. from left of footing)


Tangent (ft)
TA ( ft2 )

0
0.00
0.00

0.75
4.50
2.30

1.50
6.00
3.99

2.25
6.87
4.86

3.00
7.35
5.36

3.75
7.50
11.17

4.50
7.35
5.36

5.25
6.87
4.86

6.00
6.00
3.99

6.75
4.50
2.30

7.50
0.00
0.00

Mu,col (ft-k)

-31.84

6.82

77.32

Vu,col (k)

47

94.0

94.0

94.0

94.0

qu,ftg & fill (ksf)

0.34

0.34

0.34

0.34

0.34

0.34

0.34

0.34

0.34

0.34

0.34

Mu,ftg & fill (ft-k)

0.00

0.00

0.58

2.16

4.97

9.13

16.11

24.43

33.98

44.53

55.67

Vu,ftg & fill (k)

0.00

0.39

1.44

2.93

4.65

7.42

10.20

11.91

13.40

14.46

14.84

qu,soil (ksf)

0.93

1.24

1.54

1.85

2.16

2.46

2.77

3.08

3.39

3.69

4.00

Mu,soil (ft-k)

0
-1.42

147.82 218.32 288.82


94.0

-2.0199 -8.4177 -21.204 -42.205 -82.787 -133.92 -195.69 -267.07 -344.49

Vu,soil (k)

Mu (ft-k)

-0.7203 -1.4405 -6.2532 -16.231 -64.913 -59.861 -32.173 -13.894 -6.9468

Vu (kips)

-1.0337 -4.4745 -10.557 -19.107

FOOTING MOMENT & SHEAR FOR CASE 3


Section
0
1/10 D

-5.9175 -13.486 -23.752 -43.292 -64.476 -79.37

-93.6

-104.6 -108.84

11.13

39.723 26.544 13.801 3.8584

2/10 D

3/10 D

4/10 D

Center

6/10 D

7/10 D

8/10 D

9/10 D

Xu (ft, dist. from left of footing)


Tangent (ft)
TA ( ft2 )

0
0.00
0.00

0.75
4.50
2.30

1.50
6.00
3.99

2.25
6.87
4.86

3.00
7.35
5.36

3.75
7.50
11.17

4.50
7.35
5.36

5.25
6.87
4.86

6.00
6.00
3.99

6.75
4.50
2.30

7.50
0.00
0.00

Mu,col (ft-k)

-31.84

-30.68

2.32

35.32

68.32

101.32

Vu,col (k)

22

44.0

44.0

44.0

44.0

44.0

qu,ftg & fill (ksf)

0.25

0.25

0.25

0.25

0.25

0.25

0.25

0.25

0.25

0.25

0.25

Mu,ftg & fill (ft-k)

0.00

0.00

0.43

1.62

3.73

6.85

12.08

18.32

25.48

33.40

41.75

Vu,ftg & fill (k)

0.00

0.29

1.08

2.20

3.48

5.57

7.65

8.94

10.05

10.84

11.13

qu,soil (ksf)

0.00

0.12

0.55

0.98

1.41

1.84

2.28

2.71

3.14

3.57

2.81

Mu,soil (ft-k)

__

-0.1226 -1.2188 -4.4261 -10.982 -26.656 -47.721 -74.601 -107.02 -143.07

Vu,soil (k)

Mu (ft-k)

-0.0937 -0.932 -3.2909 -7.4659 -16.999 -28.094 -36.663 -45.346 -52.357 -55.133
0.156

0.312

-0.696 -35.973 -45.256 -27.078 -13.797 -6.8985

Vu (kips)

0.196

0.1502 -1.0938 -3.9821 10.567 23.555 16.273 8.7048 2.4859

0.4045

Page 92 of 533
524

(cont'd)
FOOTING MOMENT & SHEAR SUMMARY
Section
0
Xu (ft, dist. from left of footing)
Tangent (ft)

0
0.00

Uniform Loads

Case Mu, (ft-k / ft)


1

Vu, (k / ft)

Case Mu, (ft-k / ft)


2

Vu, (k / ft)

Case Mu, (ft-k / ft)


Vu, (k / ft)

1/10 D

2/10 D

3/10 D

4/10 D

Center

6/10 D

7/10 D

8/10 D

9/10 D

0.75
4.50

1.50
6.00

2.25
6.87

3.00
7.35

3.75
7.50

4.50
7.35

5.25
6.87

6.00
6.00

6.75
4.50

7.50
0.00

-0.4719 -0.7078 -2.308 -4.9607 -8.9245 -4.9607 -2.308 -0.7078 -0.4719

-0.6292 -1.7628 -3.1236 -4.6331

4.6331 3.1236 1.7628 0.6292

-0.1601 -0.2401 -0.9097 -2.2087 -8.6551 -8.146 -4.6804 -2.3156 -1.5437

-0.2297 -0.7458 -1.5358 -2.6001

1.484

5.4056 3.8616 2.3002 0.8574

0.0347

0.052

0.0589 -0.0947 -4.7964 -6.1586 -3.9393 -2.2995 -1.533

0.0435

0.025

-0.1591 -0.5419

1.409

3.2054 2.3673 1.4508 0.5524

smax

provD

CHECK FLEXURE
Location

Mu,max

Top Slab
Bottom Slab

0.1
-8.9

d (in)
ft-k / ft
ft-k / ft

15.75
14.63

min

reqD

max

0.0000 0.0000 0.0155 no limit 0.0003


0.0010 0.0008 0.0155
18
0.0017

[Satisfactory]

CHECK FLEXURE SHEAR


Vc = 2 b d (fc')0.5

Vu,max
5.4

k / ft

14

check Vu < Vc

[Satisfactory]

CHECK PUNCHING SHEAR (ACI 318-08 SEC.15.5.2, 11.11.1.2, 11.11.6, & 13.5.3.2)

v u ( psi ) =
3
d b1

J =

R=

P u R 0.5 v M u b1
+
J
AP
1+

d
b1

2
+3

A P = 2 ( b1 + b 2 ) d
1
v = 1
2 b1
1+
3 b2
2
D
Af =
4

b2
b1

P u b1b2
Af

vc( psi ) = ( 2 + y ) f 'c


y = MIN 2,

, 40

d
b0

b0
b 0 = ( d col + d ) , b1 = b 2 =
4

Case

Pu

Mu

b1

b2

b0

Af

Ap

vu (psi)

1
2
3

108.8
94.0
44.0

0.0
63.7
63.7

21.4
21.4
21.4

21.4
21.4
21.4

7.1
7.1
7.1

0.4
0.4
0.4

1.0
1.0
1.0

2.0
2.0
2.0

44.2
44.2
44.2

9.0
9.0
9.0

7.8
6.7
3.2

5.4
5.4
5.4

77.9
67.5
31.7

0.75

where

(ACI 318-08, Section 9.3.2.3 )

__
Page 93 of 533
524

vc
164.3
164.3
164.3
[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Tank Footing Design Based on ACI 318-08


INPUT DATA
TANK HEIGHT

H = 24.17 ft

TANK DIAMETER

d = 38.67 ft

TANK THICKNESS

t=

in

WT OF TANK & MAX CONTENTS

W = 1920.1 kips

SOIL WEIGHT

ws =

0.11

FOOTING EMBEDMENT DEPTH

Df =

ft

T=

18

in

Qa =

ksf

FOOTING THICKNESS
ALLOW SOIL PRESSURE

kcf

FOOTING DIAMETER

D = 40.67 ft

TOTAL ANCHORAGE POINTS

n=

26

( @ 56" o.c. along perimeter.)

ANCHOR BOLT DIAMETER

3/4

in

CONCRETE STRENGTH

fc' =

ksi

REBAR YIELD STRESS

fy =

60

ksi

FOOTING REBAR

2
@

#
18

6
in o.c. each way, at top & bot.

DESIGN SUMMARY
FOOTING 40.67 ft DIA x 18 in THK. w/ #6 @ 18" o.c. EACH WAY, AT TOP & BOT.

THE FOOTING DESIGN IS ADEQUATE.


ANALYSIS
DETERMINE LATERAL LOADS

T = 7.65 10 6

L
D

wD
t

Where L =
24.17
w =W/L=
D =
38.67
V = (S DS I E W / 1.4) 0.30
Where S DS =
IE =
Factor =

IE =
Factor =

=
ft
79439
ft

0.013 sec, (SEAOC IBC 06 Manual I, page 188)

<
0.06 sec
(rigid nonbuilding structure, ASCE 7-05, 15.4.2)

plf

0.12 W =

221.35 kips, ASD (for IBC, Seismic)

0.538 (ASCE 7-05, 11.4.4)


1.00
0.30

V = (C a I E W / 1.4) 0.7
Where C a =

1/ 2

(IBC 09 Tab 1604.5 & ASCE 7-05 Tab 11.5-1)


(ASCE 7-05, 15.4.2)
=

0.14 W =

268.81 kips, ASD (for CBC 2001 / UBC 97, Seismic)

0.28

(CBC 2001 / UBC 97 1634.3)

1.00
0.7

(CBC 2001 / UBC 97 Table 16-K)


(CBC 2001 / UBC 97 1634.3)

V = (2 / 3) P A =
0.01 W =
15.58 kips, ASD (for Wind)
Where A =
934.65 ft2, (projected area)
P =
25
psf, (wind pressure)
Circular Factor =
2/3
CONSIDERING SLOSHING EFFECTS, USE 295.69 kips.

COMBINED LOADS AT TOP FOOTING (IBC 1605.3.2 & ACI 318-08 9.2.1)
CASE 1:
DL + LL
P
=
1920 kips
M
=
0
ft-kips
e
=
0.0 ft, fr cl ftg
CASE 2:
DL + LL + E / 1.4
P
=
1920 kips
M
=
3647 ft-kips
e
=
1.9 ft, fr cl ftg
CASE 3:
0.9 DL + E / 1.4
P
=
393 kips
M
=
829 ft-kips
e
=
2.1 ft, fr cl ftg

1.2 DL + 1.6 LL

1.2 DL + 1.0 LL + 1.0 E

__

0.9 DL + 1.0 E

Pu
Mu
eu
Pu
Mu
eu
Pu
Mu
eu

=
=
=
=
=
=
=
=
=

2897
0
0.0
2007
5106
2.5
393
1161
3.0

CHECK OVERTURNING FACTOR AT WIND LOAD WITHOUT CONTENTS (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
MR / MO =

55.6

>

1.1667

Where MO =

Vwind (2 / 3) (H + T) =

Pftg =

(0.15 kcf) T D2 / 4 =

[Satisfactory]

267

k-ft ,

292.29 k, footing weight.

Page 94 of 533
524

MR =

(PDL + Pftg) 0.5 D =

F = 1.5, for wind

14822

k-ft

kips
ft-kips
ft, fr cl ftg
kips
ft-kips
ft, fr cl ftg
kips
ft-kips
ft, fr cl ftg

(cont'd)

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)


Service Loads
P
e

CASE 1
1920.1
0.0

CASE 2
1920.1
2.1

CASE 3
392.9
2.9

Pftg - Psoil
P
e

149.4
2069.4
0.0

149.4
2069.4
1.9

134.5
527.4
2.1

qmin
x

1.6

1.0
@ 0.00 ft from edge

0.2
@ 0.00 ft from edge

ksf

qmax

1.59

2.22

0.58

ksf

qallowable

2.00

2.67

2.67

ksf

k
ft (from center of footing)
k, (footing increasing)
k, (net loads)
ft

[Satisfactory]
CHECK ENTIRE FLEXURE & SHEAR OF FOOTING
(ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, 12.5, 15.5.2, 11.1.3.1, & 11.2)

MIN = MIN 0.0018


0.85 f c 1 1
'

T
4

,
d
3

MAX =

0.85 1 f c'
f y

u
u +t

Mu
0.383b d 2 f c'

fy

FACTORED SOIL PRESSURE


Factored Loads
CASE 1
Pu
eu
(0.15 T) A
Pu

CASE 2

CASE 3

2897.4

2007.4

392.9

0.0
350.8

2.7
350.8

4.0
263.1

ft
k, (factored footingloads)

3248.2

2358.1

656.0

eu

0.0

2.3

2.4

ft

qu, min
x

2.50

0.94
@ 0.00 ft from edge

0.25
@ 0.00 ft from edge

ksf

2.50

2.69

0.75

ksf

qu, max

FOOTING MOMENT & SHEAR FOR CASE 1


0
L Edge
Section

1/8 d

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

Xu (ft, dist. from left of footing)


Tangent (ft)

0
0.00

1.00
12.60

5.83
28.51

10.67
35.78

15.50
39.50

20.34
40.67

25.17
39.50

30.00
35.78

34.84
28.51

39.67
12.60

40.67
0.00

qu,tank (ksf)

0.00

2.47

2.47

2.47

2.47

2.47

2.47

2.47

2.47

2.47

0.00

Mu,tank (ft-k)

298

2,076

5,793

11,676 19,798 30,087 42,314 56,022 58,920

Vu,tank (k)

62

368

769

1,680

2,129

2,530

2,836

2,897

2,897

qu,ftg (ksf)

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

Mu,ftg (ft-k)

58

297

763

1,481

2,459

3,688

5,145

6,784

7,133

Vu,ftg (k)

12

49

96

202

254

301

339

349

351

qu,soil (ksf)

-2.50

-2.50

-2.50

-2.50

-2.50

-2.50

Mu,soil (ft-k)

Vu,soil (k)

-16

-109

-457

-894

-1,872

-2,355

-2,791

-3,139

-3,232

-3,248

Mu (ft-k)

-14

-185

-376

-513

-561

-513

-376

-185

-14

Vu (kips)

-14

-35

-40

-28

10

28

40

35

14

__
-2.50

-2.50

-2.50

-2.50

-2.50

-15.907 -541.36 -2749.3 -7068.6 -13719 -22770 -34151 -47644 -62820 -66052

Page 95 of 533
524

(cont'd)

FOOTING MOMENT & SHEAR FOR CASE 2


Section
0
L Edge

1/8 d

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

Xu (ft, dist. from left of footing)


Tangent (ft)

0
0.00

1.00
12.60

5.83
28.51

10.67
35.78

15.50
39.50

20.34
40.67

25.17
39.50

30.00
35.78

34.84
28.51

39.67
12.60

40.67
0.00

qu,tank (ksf)

0.00

0.69

1.05

1.30

1.56

1.81

2.07

2.32

2.58

2.73

0.00

Mu,tank (ft-k)

16000

23918

33295

35300

Vu,tank (k)

16

139

340

929

1,284

1,641

1,943

2,007

2,007

qu,ftg (ksf)

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

Mu,ftg (ft-k)

58

297

763

1,481

2,459

3,688

5,145

6,784

7,133

78.504 751.09 2390.2 5321.1 9803.9

Vu,ftg (k)

12

49

96

202

254

301

339

349

351

qu,soil (ksf)

-0.94

-0.98

-1.19

-1.40

-1.61

-1.82

-2.02

-2.23

-2.44

-2.65

-2.69

Mu,soil (ft-k)

-6.0025 -212.05 -1222.9 -3420.5 -7123.3 -12577 -19926 -29168 -40061 -42432

Vu,soil (k)

-6

-43

-209

-455

-1,128

-1,520

-1,912

-2,253

-2,352

-2,358

Mu (ft-k)

-4

-75

-175

-267

-321

-314

-238

-105

-19

Vu (kips)

-4

-15

-20

-18

18

30

29

FOOTING MOMENT & SHEAR FOR CASE 3


0
L Edge
Section

1/8 d

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

Xu (ft, dist. from left of footing)


Tangent (ft)

0
0.00

1.00
12.60

5.83
28.51

10.67
35.78

15.50
39.50

20.34
40.67

25.17
39.50

30.00
35.78

34.84
28.51

39.67
12.60

40.67
0.00

qu,tank (ksf)

0.00

0.04

0.15

0.22

0.29

0.36

0.44

0.51

0.58

0.63

0.00

Mu,tank (ft-k)

Vu,tank (k)

18

51

162

236

312

379

393

393

qu,ftg (ksf)

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

Mu,ftg (ft-k)

44

223

572

1,111

1,844

2,766

3,859

5,088

5,349

Vu,ftg (k)

37

72

152

191

226

254

262

263

qu,soil (ksf)

-0.25

-0.27

-0.33

-0.39

-0.45

-0.50

-0.56

-0.62

-0.68

-0.74

-0.75

Mu,soil (ft-k)

-1.63

-57.69 -334.65 -939.25 -1961.3 -3470.3 -5508.1 -8075.3 -11104 -11765

Vu,soil (k)

-2

-12

-57

-125

-312

-422

-531

-627

-654

-656

Mu (ft-k)

-9

-21

-32

-36

-28

-7

24

51

Vu (kips)

-2

-3

-2

FOOTING MOMENT & SHEAR SUMMARY


Section
0
Xu (ft, dist. from left of footing)
Tangent (ft)
Case Mu, (ft-k / ft)
Uniform Loads

4.8533 90.535 334.56 814.32 1598.2 2735.2 4240.6 6067.5 6415.2

Vu, (k / ft)

Case Mu, (ft-k / ft)


2

Vu, (k / ft)

Case Mu, (ft-k / ft)


3

Vu, (k / ft)

L Edge

1/8 d

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

0
0.00

1.00
12.60

5.83
28.51

10.67
35.78

15.50
39.50

20.34
40.67

25.17
39.50

30.00
35.78

34.84
28.51

39.67
12.60

40.67
0.00

0.0

-1.1

-6.5

-10.5

-13.0

-13.8

-13.0

-10.5

-6.5

-1.1

0.0

0.0

-1.1

-1.2

-1.1

-0.7

0.2

0.7

1.1

1.2

1.1

0.0

0.0

-0.3

-2.6

-4.9

-6.8

-7.9

-8.0

-6.6

-3.7

-1.5

0.0

0.0

-0.3

-0.5

-0.6

-0.5

0.1

0.5

0.8

1.0

0.3

0.0

0.0

0.0

-0.3

-0.6

-0.8

-0.9

-0.7

-0.2

0.8

4.0

0.0

0.0

0.0

-0.1

-0.1

-0.1

0.0

0.1

0.2

0.2

0.0

0.0

min

reqD

max

smax

provD

CHECK FLEXURE
Location

Mu,max

Top Slab
Bottom Slab

4.0
-13.8

d (in)
ft-k / ft
ft-k / ft

15.63
14.63

0.0004 0.0003 0.0155 no limit 0.0016


0.0016 0.0012 0.0155
18
0.0017

[Satisfactory]

CHECK FLEXURE SHEAR


Vc = 2 b d (fc')0.5

Vu,max
1.2

k / ft

14

check Vu < Vc
[Satisfactory]

__

Technical References:
1. "Seismic Design Manual (UBC 97) - Volume 1, Code Application Examples", Structural Engineers
Association of California, 1999.
2. "2006 IBC Structural/Seismic Design Manual - Volume 1, Code Application Examples", Structural Engineers
Association of California, 2007.

Page 96 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Basement Concrete Wall Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH
REBAR YIELD STRESS
LATERAL SOIL PRESSURE
BACKFILL SPECIFIC WEIGHT

SURCHARGE WEIGHT
WALL LATERAL FORCE, ASD
SERVICE GRAVITY LOAD
ECCENTRICITY
SEISMIC GROUND SHAKING
HEIGHT ABOVE GROUND
HEIGHT UNDER GROUND
THICKNESS OF WALL
WALL VERT. REINF. (As)

fc '
fy
Pa
b
ws
wLat
P
e
PE
H1
H2
t

=
=
=
=
=
=
=
=
=
=
=
=
#

3
60
45
110
100
25
20
6
48
1.4
12.5
10
5

As LOCATION (1=at middle, 2=at each face)

WALL HORIZ. REINF.

ksi
ksi
pcf (equivalent fluid pressure)
pcf
psf
psf
kips / ft
in
psf / ft (for H > 12 ft, CBC 07 1806A.1)

ft
ft
in
@

18

in o.c.

at each face
@

18

in o.c.

[THE WALL DESIGN IS ADEQUATE.]

ANALYSIS
Case A: Fixed Bottom & Pinned Top, with Lateral Soil Pressure Increasing Uniformly to Bottom
SERVICE LOADS
Hb = 0.5 Pa H22
Hs = ws Pa H2 / b
HLat = wLat (H1 + H2)
HE = 0.5 PE (H2)2
Ww = t ( H1 + H2 ) c
FACTORED LOADS
Hb = 1.6 Hb
Hs = 1.6 Hs
HLat = 1.6 HLat

=
=
=
=
=

3.52
0.51
0.35
3.75
1.74

kips / ft
kips / ft
kips / ft
kips / ft
kips / ft

=
=
=
=
=
=

5.63 kips / ft
0.82 kips / ft
0.56 kips / ft
HE = 1.6 HE
6.00 kips / ft
Ww = 1.2 Ww
2.09 kips / ft
P = 1.6 P
32.00 kips / ft
DETERMINE FACTORED SECTION FORCES

__
Page 97 of 533
524

RT =
RB =
PB =
MB =
S =
PM =
MM =

5.89
7.11
34.09
16.53
7.00
33.04
8.32

kips / ft
kips / ft
kips / ft
ft-kips / ft
ft, at max moment
kips / ft
ft-kips / ft

(cont'd)

Case B: Pinned both Bottom & Top, with Lateral Soil Pressure Trapezium Distributed

L =
Hb =
Hb =
RT =
RB =
S =
PM =
MM =

0.6
1.13
1.80
6.20
2.97
6.13
33.16
13.82

H2
kips / ft
kips / ft
kips / ft
kips / ft
ft, at max moment
kips / ft
ft-kips / ft

CHECK MINIMUN HORIZ. REINF.


ProvD = 0.00344
0.002
>
MIN =
(ACI 318-08 14.3.3)
[Satisfactory]
CHECK VERT. FLEXURE CAPACITY
< MAX = 0.04 (tension face only, ACI 318-05 10.3.5 or 10.9.1)
ProvD = 0.00224
> MIN = 0.00075 (tension face only, ACI 318-05 10.5.1, 10.5.3 or 14.3.2)
[Satisfactory]

200.0
180.0
160.0
140.0
120.0
Pn (k)

Pn

Mn

AT AXIAL LOAD ONLY


AT MAXIMUM LOAD
AT MIDDLE
AT t = 0.002
AT BALANCED

171.5
171.5
115.5
59.5
58.1

0.0
8.0
19.3
22.5
22.6

AT t = 0.005

42.7

25.4

80.0

AT FLEXURE ONLY

0.0

7.0

60.0

(Note: For middle reforcing the max M n is at c

100.0

equal to 0.5 t / 1 , not at balanced condition.)


Case A
Case B

40.0
20.0
0.0
0.0

5.0

10.0

15.0

20.0

25.0

30.0

at bottom

at middle

Pu

34.09

33.04

33.16

Mu

16.53

8.32

13.82

Mn (ft-k)

[Satisfactory]

CHECK SHEAR CAPACITY (ACI 318-08 SEC.15.5.2, 11.1.3.1, & 11.2)

V u = Max. Horiz. Shear

7.11

kips, at bottom

V n = 2 bd

7.58

kips

'

fc

__
Page 98 of 533
524

>

Vu

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Basement Masonry Wall Design Based on TMS 402-08


INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
=
MASONRY STRENGTH
fm'
REBAR YIELD STRESS
fy
=
LATERAL SOIL PRESSURE
Pa
=
BACKFILL SPECIFIC WEIGHT
b
=
=
SURCHARGE WEIGHT
ws
WALL LATERAL FORCE, ASD wLat
=
SERVICE GRAVITY LOAD
P
=
ECCENTRICITY
e
=
SEISMIC GROUND SHAKING
PE
=
=
HEIGHT ABOVE GROUND
H1
HEIGHT UNDER GROUND
H2
=
THICKNESS OF WALL
t
=
WALL VERT. REINF. (As)
#

1
1
1.5
60
40
110
100
25
20
6
20
1.4
12.5
12
8

As LOCATION (1=at middle, 2=at each face)

WALL HORIZ. REINF.

Yes
CMU
ksi
ksi
pcf (equivalent fluid pressure)
pcf
psf
psf
kips / ft
in
psf / ft (for H > 12 ft, CBC 07 1806A.1)

ft
ft
in
@

in o.c.

32

in o.c.

at each face
@

[THE WALL DESIGN IS ADEQUATE.]

ANALYSIS
Case A: Fixed Bottom & Pinned Top, with Lateral Soil Pressure Increasing Uniformly to Bottom
SERVICE LOADS
Hb = 0.5 Pa H22
Hs = ws Pa H2 / b
HLat = wLat (H1 + H2)

=
=
=
=
=

3.13
0.45
0.35
1.56
1.81

HE = 0.5 PE (H2)2
Ww = t ( H1 + H2 ) m
ALLOWABLE STRESS DESIGN LOADS
Hb = 1.0 Hb
= 3.13 kips / ft
Hs = 1.0 Hs
= 0.45 kips / ft
HLat = 1.0 HLat
= 0.35 kips / ft
HE = 1.0 HE
= 1.56 kips / ft
Ww = 1.0 Ww
= 1.81 kips / ft
P = 1.0 P
= 20.00 kips / ft
DETERMINE FACTORED SECTION FORCES

kips / ft
kips / ft
kips / ft
kips / ft
kips / ft

__
Page 99 of 533
524

RT =
RB =
PB =
MB =
S =
PM =
MM =

2.59
2.90
21.81
5.29
7.25
20.86
0.47

kips / ft
kips / ft
kips / ft
ft-kips / ft
ft, at max moment
kips / ft
ft-kips / ft

(cont'd)

Case B: Pinned both Bottom & Top, with Lateral Soil Pressure Trapezium Distributed

L =
Hb =
Hb =
RT =
RB =
S =
PM =
MM =

0.6
1.00
1.00
2.48
0.88
3.82
21.31
3.78

H2
kips / ft
kips / ft
kips / ft
kips / ft
ft, at max moment
kips / ft
ft-kips / ft

CHECK MINIMUN HORIZ. REINF.


ProvD = 0.00104
>
MIN =
0.0007
(TMS 402-08 1.13.6.3)
[Satisfactory]
CHECK VERT. FLEXURE CAPACITY (TMS 402 2.3.3)
> SUM =
> MIN =
[Satisfactory]

ProvD = 0.01039

M m = MIN

0.0010 (horizontal and vertical at least 0.002, TMS 402-08 1.13.6.3)


0.0007 (TMS 402-08 1.13.6.3)

kd
1
t
P d e
b wkd F b d
2
3
2

, AsF s d

kd
kd
t
+P e
3
2 3

, allowable moment

where

Case B

Case A

Loads

As =

1.185

in2

d=

9.380

in

at bottom

at middle

21.81

20.86

21.31

bw =

12

in

5.29

0.47

3.78

te =

11.63

in

Mm

5.30

5.58

5.44

Em =

1350

ksi

Fb =

0.66

ksi

Es = 29000 ksi
n = 21.5

= 0.01053
SF = 1.33
k = 0.4834
Fs =

32

[Satisfactory]
CHECK SHEAR CAPACITY (TMS 402 2.3.5)

fv=
<

( Max.

Horiz. Shear )
b wt e

F v = ( SF ) MIN

20.8

'
f m , 50 =

psi, at bottom

51.6

psi

__
Page 100 of 533
524

[Satisfactory]

ksi

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Temporary Tank Footing Design Based on ACI 318-08


INPUT DATA

DESIGN SUMMARY

TANK SIZE
BASE PLATE EDGE SIZE

c1

40

ft

FOOTING WIDTH

22.00

c2

20

ft

FOOTING LENGTH

42.00

ft

b1

40.5

ft

FOOTING EDGE THICKNESS

10

in

ft

b2

20.5

FOOTING CONCRETE STRENGTH


REBAR YIELD STRESS
TOTAL DEAD LOAD

fc'
fy
PDL

=
=
=

2
60
23

ksi
ksi
kips

LIVE LOAD

PLL

1450

kips

SURCHARGE
SOIL WEIGHT
FOOTING EMBEDMENT DEPTH
FOOTING EDGE THICKNESS
ALLOW SOIL PRESSURE
FOOTING WIDTH
FOOTING LENGTH

qs
ws
Df
T
Qa
B
L

=
=
=
=
=
=
=

0.1
0.11
0.50
10
2
22
42

ksf
pcf
ft
in
ksf
ft
ft

ft

THE FOOTING DESIGN IS ADEQUATE.

ANALYSIS
DESIGN LOADS (ACI 318-08 SEC.9.2.1)
ASD:
DL + LL
P
SD:
1.2 DL + 1.6 LL
Pu

=
=

1582
2189

kips
kips

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)


ASD
P
q MAX =
<
=
1.71
ksf,
Qa

[Satisfactory]

BL

DESIGN FOR FLEXURE (ACI 318-08 SEC.22.5.1)

M n = MIN 5

where

Mu =

'
'
f c S , 0.85 f cS

=
=

49.19

ft-kips

0.6 (ACI 318-08, Section 9.3.5 )


elastic section modulus of section

( 0.5L 0.25b10.25c1)

P u ,max

2L

19.95

<

ft-kips

4400

in3

[Satisfactory]

CHECK FLEXURE SHEAR (ACI 318-08 SEC.22.5.4)

4
3

V n =

'

f c BT

where

94.45 kips

0.6

(ACI 318-08, Section 9.3.5 )

P u ,max
V u = ( 0.5L 0.25b1 0.25c1 T )
L

2.17

kips

<

[Satisfactory]

CHECK PUNCHING SHEAR (ACI 318-08 SEC.22.5.4)

V n = MIN

4
8
+
, 2.66
3 3 c

where

V u = P u ,ma x 1

=
=

f c ( c1 + c2 + b1 + b2 + 4T ) T
'

= 1064.92 kips

0.6 (ACI 318-08, Section 9.3.5 )


ratio of long side to short side of concentrated load

1 b1 + c 1
+T
BL
2

b2+ c2 +T
2

__
=

136.98 ft-kips

Page 101 of 533


524

1.99

<

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

UnderGround Well Design Based on ACI 350-06 & ACI 318-08


INPUT DATA
WELL DEPTH

H=

WELL OUTSIDE DIAMETER

28.5

ft

dia = 8.3333 ft
t=

in

FOOTING DIAMETER

WELL CONCRETE THICKNESS

D=

16

ft

FOOTING THICKNESS

T=

18

in

WATER TABLE LOCATION

h=

ft

WT OF WELL & MAX CONTENTS

W well = 171.61 kips

WT OF TOP CAP

W cap = 18.869 kips


Qa =

ksf

SOIL WEIGHT

s =

0.11

kcf

LATERAL SOIL PRESSURE

Pa =

45

pcf (equivalent fluid pressure)

PASSIVE PRESSURE

Pp =

450

psf / ft

SEISMIC GROUND SHAKING

PE =

30

psf / ft

CONCRETE STRENGTH

fc' =

ksi

fy =

60

ksi

ALLOWABLE SOIL PRESSURE

REBAR YIELD STRESS


FOOTING REBAR

Layers

16

in o.c. each way, at top & bot.


#

DOWEL LOCATION (1=at middle, 2=at each face)

DOWEL / WELL VERTICAL REBARS

WELL HORIZONTAL REBARS

in o.c.

18

in o.c.

at each face
@

DESIGN SUMMARY

THE FOOTING DESIGN IS ADEQUATE.

FOOTING 16 ft DIA x 18 in THK. w/ # 6 @ 16" o.c. EACH WAY, AT TOP & BOT.
CONCRETE WELL 8 in THK. w/ # 5 @ 8 in o.c.DOWEL / VERT. BARS AT AT EACH FACE

ANALYSIS
DETERMINE LATERAL LOADS
F = (S DS I E W / 1.4)
Where S DS =

0.30

0.12 W, ASD (for IBC, Seismic)

0.538 (ASCE 7-05, 11.4.4)

IE =

1.00

(IBC 09 Tab 1604.5 & ASCE 7-05 Tab 11.5-1)

Factor =

0.30

, (ASCE 7-05, 15.4.2)

Fcap =

0.12 W cap =

Fwell =

0.12 W well = 19.78 kips, at mid of H

2.18

kips, at ground

Ha = 0.5 Pa H2 (2/3 d) =

101.53 kips, at 1/3 H

HE = 0.5 PE H2 (2/3 d) =

67.69 kips, at 2/3 H

14.923

Hp = MIN [ 0.5 Pp H (2/3 d) , (F + H)] =


2

V=
M=

0.00
778

191.18 kips, at 1/3 H


186.32
kips, total shear at top of footing
ft-kips, total moment at top of footing
755.25

COMBINED LOADS AT TOP FOOTING (IBC 1605.3.2 & ACI 318-08 9.2.1)
CASE 1:
DL + LL
P
=
190 kips
M
=
0
ft-kips
e
=
0.0 ft, fr cl ftg
CASE 2:
DL + LL + E / 1.4
P
=
190 kips
M
=
778 ft-kips
e
=
4.1 ft, fr cl ftg
CASE 3:
0.9 DL + E / 1.4
P
=
13
kips
M
=
755 ft-kips
e
=
56.2 ft, fr cl ftg

1.2 DL + 1.6 LL

Pu
Mu
eu
Pu
Mu
eu
Pu
Mu
eu

1.2 DL + 1.0 LL + 1.0 E

0.9 DL + 1.0 E

=
=
=
=
=
=
=
=
=

CHECK OVERTURNING FACTOR AT FOOTING EDGE BOTTOM (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
MR / MO =
Where MO =
W ftg =

2.4
M+VT =

>

1.5
778

(0.15 kcf) T D2 / 4 =

[Satisfactory]
MR =

k-ft ,
45.24

kips, footing weight.

(W) 0.5 D =

1886

k-ft

269
0
0.0
175
1090
6.2
13
1057
78.7

kips
ft-kips
ft, fr cl ftg
kips
ft-kips
ft, fr cl ftg
kips
ft-kips
ft, fr cl ftg

(cont'd)
CHECK UPLIFT CAPACITY UNDER MINIMUM CONTENTS & TOP OPENING
W Gravity / FUplift = 43.784
>
1.5
[Satisfactory]
Where FUplift = (d2 / 4) (H + T - h) water =
=

30

W soil =

2645

102.1

kips

4470

kips

, from soil report

kips, cone soil weight

W Gravity = W ftg + W soil + W concrete =

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)

Service Loads
P
e

CASE 1
190.5
0.0

CASE 2
190.5
4.1

CASE 3
13.4
56.2

Pftg - Psoil
P
e

12.1
202.5
0.0

12.1
202.5
3.8

10.9
24.3
31.1

qmin
x

1.0

0.0
@ 4.80 ft from edge

0.0
@ 8.00 ft from edge

ksf

qmax

1.01

3.47

3.85

ksf

qallowable

3.00

4.00

4.00

ksf

k
ft (from center of footing)
k, (footing increasing)
k, (net loads)
ft

[Satisfactory]
CHECK ENTIRE FLEXURE & SHEAR OF FOOTING
(ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, 12.5, 15.5.2, 11.1.3.1, & 11.2)

MIN = MIN 0.0018


0.85 f c 1 1
'

T
4

,
d
3

MAX =

0.85 1 f c'
f y

u
u +t

Mu
0.383b d 2 f c'

fy

FACTORED SOIL PRESSURE


Factored Loads
CASE 1
Pu
eu
(0.15 T) A
Pu

CASE 2

CASE 3

268.6

174.6

13.4

0.0
54.3

6.2
54.3

78.7
40.7

ft
k, (factored footingloads)

322.9

228.9

54.1

eu

0.0

4.8

19.5

ft

qu, min
x

1.61

0.00
@ 6.40 ft from edge

0.00
@ 8.00 ft from edge

ksf

1.61

4.93

5.32

ksf

qu, max

FOOTING MOMENT & SHEAR FOR CASE 1


0
L Edge
Section

1/8 d

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

Xu (ft, dist. from left of footing)


Tangent (ft)

0
0.00

3.83
13.66

4.88
14.73

5.92
15.45

6.96
15.86

8.00
16.00

9.04
15.86

10.08
15.45

11.13
14.73

12.17
13.66

16.00
0.00

qu,tank (ksf)

0.00

4.92

4.92

4.92

4.92

4.92

4.92

4.92

4.92

4.92

0.00

Mu,tank (ft-k)

21

67

149

269

429

627

860

1,119

2,149

Vu,tank (k)

20

45

78

153

190

224

249

269

269

qu,ftg (ksf)

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

Mu,ftg (ft-k)

24

38

56

79

105

135

169

208

250

434

Vu,ftg (k)

14

18

21

29

33

37

40

48

54

qu,soil (ksf)

-1.61

-1.61

-1.61

-1.61

-1.61

-1.61

-1.61

-1.61

-1.61

-1.61

-1.61

Mu,soil (ft-k)

-139.95 -226.35 -335.03 -467.1 -623.16 -803.44 -1007.7 -1235.4 -1485.3 -2583.1

Vu,soil (k)

-37

-83

-104

-127

-173

-196

-219

-240

-286

-323

Mu (ft-k)

-116

-168

-211

-240

-250

-240

-211

-168

-116

Vu (kips)

-30

-49

-42

-27

27

42

49

30

(cont'd)
FOOTING MOMENT & SHEAR FOR CASE 2
0
L Edge
Section

1/8 d

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

Xu (ft, dist. from left of footing)


Tangent (ft)

0
0.00

3.83
13.66

4.88
14.73

5.92
15.45

6.96
15.86

8.00
16.00

9.04
15.86

10.08
15.45

11.13
14.73

12.17
13.66

16.00
0.00

qu,tank (ksf)

0.00

-16.90

25.12

30.14

35.17

40.19

45.22

50.25

55.27

23.31

0.00

Mu,tank (ft-k)

-1.587

-0.151

6.0352 18.418 38.115 65.779 101.36

143.6

307.08

Vu,tank (k)

-6

24

77

109

140

166

175

175

qu,ftg (ksf)

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

0.27

Mu,ftg (ft-k)

24

38

56

79

105

135

169

208

250

434

Vu,ftg (k)

14

18

21

29

33

37

40

48

54

qu,soil (ksf)

0.00

0.00

0.00

0.00

-0.29

-0.82

-1.36

-1.89

-2.43

-2.96

-4.93

Mu,soil (ft-k)

-5.4543 -26.673 -73.698 -155.76 -280.68 -741.37

Vu,soil (k)

-20

-45

-79

-120

-229

-229

Mu (ft-k)

24

36

56

85

118

147

162

153

113

Vu (kips)

23

46

86

97

98

86

-6

FOOTING MOMENT & SHEAR FOR CASE 3


Section
0
L Edge

1/8 d

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

Xu (ft, dist. from left of footing)


Tangent (ft)

0
0.00

3.83
13.66

4.88
14.73

5.92
15.45

6.96
15.86

8.00
16.00

9.04
15.86

10.08
15.45

11.13
14.73

12.17
13.66

16.00
0.00

qu,tank (ksf)

0.00

-19.26

21.51

26.39

31.26

36.14

41.02

45.90

50.77

19.75

0.00

Mu,tank (ft-k)

Vu,tank (k)

-1

11

13

13

13

qu,ftg (ksf)

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

0.20

Mu,ftg (ft-k)

18

29

42

59

79

101

127

156

187

326

Vu,ftg (k)

10

13

16

22

25

28

30

36

41

qu,soil (ksf)

0.00

0.00

0.00

0.00

0.00

0.00

-0.69

-1.38

-2.08

-2.77

-5.32

Mu,soil (ft-k)

0.3388 1.2438 2.7185 4.8192 7.5464 10.803

-4E-15 -4.0895 -16.144 -39.588 624.18

Vu,soil (k)

-4

-12

-23

-54

-54

18

28

42

59

80

104

128

147

159

Vu (kips)

10

13

18

28

29

27

21

-5

Xu (ft, dist. from left of footing)


Tangent (ft)
Case Mu, (ft-k / ft)
1

Vu, (k / ft)

Case Mu, (ft-k / ft)


2

Vu, (k / ft)

Case Mu, (ft-k / ft)


3

Vu, (k / ft)

L Edge

1/8 d

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

0
0.00

3.83
13.66

4.88
14.73

5.92
15.45

6.96
15.86

8.00
16.00

9.04
15.86

10.08
15.45

11.13
14.73

12.17
13.66

16.00
0.00

0.0

-8.5

-11.4

-13.7

-15.1

-15.6

-15.1

-13.7

-11.4

-8.5

0.0

0.0

-2.2

-3.3

-2.7

-1.7

0.6

1.7

2.7

3.3

2.2

0.0

0.0

1.7

2.5

3.6

5.3

7.4

9.2

10.5

10.4

8.2

0.0

0.0

0.4

0.5

1.5

2.9

5.4

6.1

6.3

5.9

-0.4

0.0

0.0

1.3

1.9

2.7

3.7

5.0

6.6

8.3

10.0

11.6

0.0

0.0

0.3

0.7

0.9

1.1

1.7

1.8

1.7

1.4

-0.3

0.0

min

reqD

max

smax

provD

CHECK FLEXURE
Location

Mu,max

Top Slab
Bottom Slab

11.6
-15.6

d (in)
ft-k / ft
ft-k / ft

15.63
14.63

0.0012 0.0009 0.0206 no limit 0.0018


0.0018 0.0014 0.0206
18
0.0019

[Satisfactory]

CHECK FLEXURE SHEAR


Vc = 2 b d (fc')0.5

Vu,max
6.3

k / ft

17

check Vu < Vc

[Satisfactory]

CHECK WELL CONCRETE FLEXURAL & AXIAL CAPACITY


o =

-949.9

Mu (ft-k)

FOOTING MOMENT & SHEAR SUMMARY


Section
0

Uniform Loads

-0.1566 -0.089

2 0.85 f

'
C

, E c = 57

Ec

f
2

0.85 f

'
C

c
c

o
o

0.85 f

'
C

for c o

sE s ,
f y ,

for s y
for s > y

, E s = 29000ksi

'
C

for 0 < c < o

6000

Pn (kips)

5000
4000

Pn (k)

3000
2000

1000

(cont'd)
Mn (ft-kips)

AT AXIAL LOAD ONLY

4939

AT MAXIMUM LOAD

4939

2748

AT 0 % TENSION

4184

5008

AT 25 % TENSION

3543

6674

AT 50 % TENSION

3151

7288

AT t = 0.002

2644

7682

AT BALANCED CONDITION

2449

7206

AT t = 0.005

2365

9175

1779

AT FLEXURE ONLY
0
0

2000

4000

6000

8000

10000

Pu

175

kips

Mu

1090

ft-kips, max at bottom

Mn (ft-k)

(from load combinations)

Pmax =0.85 [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

49

4938.6 kips., (at max axial load, ACI 318-08, Sec. 10.3.6.1)

>

(ACI 318-08, Sec.9.3.2.2)

2
2312.2 in .

Ag =
a = Cb 1

0.70

in2.

Ast =

0.65 + ( t - 0.002 ) (250 / 3), for Ties


Cb = d c / (c + s) =
d

[Satisfactory]

in (at balanced strain condition, ACI 10.3.2)

0.7 + ( t - 0.002 ) (200 / 3), for Spiral

where

7.75

Pu

in2.

58

0.656

in

97.563 in, (ACI 7.7.1)

Mn = 0.9 n =1779

(ACI 318-08, Fig. R9.3.2)

t =

0.002069

1 =

0.85

c =

0.003

( ACI 318-08, Sec. 10.2.7.3 )

ft-kips @ Pn = 0, (ACI 318-08, Sec. 9.3.2) ,& et,min = 0.004, (ACI 318-08, Sec. 10.3.5)

Mn =

2325

max

0.08

min

0.003 (ACI 318-08, Section 10.5.1 or 10.9.1)

ft-kips @ Pu =

175

>

kips
provd

(ACI 318-08, Section 10.9)

Mu

[Satisfactory]

0.003
[Satisfactory]

CHECK WELL CONCRETE SHEAR CAPACITY

Vn = (Vc) =

183

kips, (ACI 318-08 Sec. 11.1.1)

>
where

0.75

A0 =

1934

Vu = 1.4 V =
3.0455 kips, max at top
(ACI 318-08 Sec. 9.3.2.3)
in2.

Vc = 2 (fc')0.5A0 =

[Satisfactory]

244.6 kips, (ACI 318-08 Sec. 11.2.1)

CHECK WELL LOCAL SHEAR STRESS ON A SQUARE FOOT

vn = (vc) =

40.73 kips, (ACI 318-08 Sec. 11.1.1)

>

where =
A0

vu = 1.4 Pmax =
3.38 kips
(ACI 318-08 Sec. 9.3.2.3)
2
= 4 x (1'-0") x (0.5 T) =
192 in .

[Satisfactory]

0.75

4 (fc')0.5A0 =

vc =
Pmax =

2415

54.3

kips, (ACI 318-08 Sec. 11.11)

psf, (the max perpendicular wall pressure)

CHECK DOWEL DEVELOPMENT

L dh = MAX

requird 0.02 ed b f y
, 8d b , 6 in =
provided f 'c

13 db =

in, (ACI 318-08 12.5.2)

[Satisfactory]
where Bar size
db

=
required / provided

60

ksi

ksi

1.0

1.0

fy

f'c
t
e
s

c
Ktr

5
0.625 in

=
=
=
=
(c + Ktr ) / db =

( A s,reqd / A s,provd , ACI 318-08, 12.2.5)

(1.2 for epoxy-coated, ACI 318-08 12.2.4)

0.8 (0.8 for # 6 or smaller, 1.0 for other)


1.0
3.3 in, min(d' , 0.5s), (ACI 318-08, 12.2.4)
(Atr fyt / 1500 s n) =
0
(ACI 318-08, 12.2.3)
2.5
0.7

< 2.5 , (ACI 318-08, 12.2.3)


(#11 or smaller, cover > 2.5" & side >2.0", ACI 318-08 12.5.3)

<

14.375 in

PROJECT :
CLIENT :
JOB NO. :
DATE :
Basement Column Supporting Lateral Resisting Frame Based on ACI 318-08

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

fc' =

4.5

ksi

REBAR YIELD STRESS


COLUMN CLEAR HEIGHT
COLUMN SIZE

fy =
h =
c1 =

60
14
24

ksi
ft
in
in

c2 =

24

AMPLIFICATION FACTOR (ASCE 7 Tab 12.2-1)

0 =

2.2

DESIGN LEVEL BASEMENT DISPLACEMENT

S =

LOADS, ASD (ft-kips, kips)


P
DL
225
LL
270
E / 1.4
-333.3
( - P for uplift)

RIGHT

Pground
157.5
90

131

0.1

LONGITUDINAL REINFORCING
SECTION
LEFT
5
(d =

TOP
#
21.37
( 1 Layer)
5
#
( d = 21.37
( 1 Layer)

in

BOTTOM
#
21.37
( 1 Layer)
5
#
( d = 21.37
( 1 Layer)

10
in )

5
(d =

10
in )

TRANSVERSE REINFORCEMENT FOR CONFINEMENT


4 Legs #
4
@

10
in )
10
in )

THE COLUMN DESIGN IS ADEQUATE.

in, o.c., full height (ACI 318-08 4.4.5)

ANALYSIS
DESIGN CRITERIA
1. Since the column supported reaction from lateral resisting frame, ASCE 7-05 12.3.3.3 apply.
2. Since the column is not part of the lateral force resisting system, ACI 318-08 21.13 apply.
3. Since the transverse reinforcement required 12" at least into footing per ACI 318-08 21.6.4.6
a condition of pinned top & fixed bottom should be used.
DESIGN LOADS AT TOP OF COLUMN
U1 = (1.20.2SDS) D + f1 L +1.0 0 Eh
-527.9

kips

Mu =

0.3

Vu =

403.5

kips

f1 =

0.5

SDS =

1.246

U3 = 1.2 D + 1.6 L

U2 = (0.90.2SDS) D 1.0 0 Eh

, (ACI 318-05 21.13)

Pu =

ft-kips

Pu =

-777.6

kips

Vu =

403.5

kips

, (ACI 318-05 9.2.1)

Pu =

891.0

kips

Vu =

0.0

kips

Mu =

0.0

ft-kips

CHECK CAPACITY SUBJECTED TO BENDING AND AXIAL LOAD


LOADING

U1,top

U1,bot

U2,top

U2,bot

U3,top

U3,bot

Pu (kips)

-527.9

-517.8

-777.6

-770.1

891.0

902.8

0.3

0.2

0.3

0.2

0.0

0.0

1.000

1.000

1.000

1.000

1.148

1.150

Mu (ft-kips)

ns = Cm/[1-Pu/(0.75Pc)]
nsMu (ft-kips)
Mn (ft-kips) @ Pu
where

0.3

0.2

0.3

0.2

0.0

0.0

426.7

822.4

822.4

822.4

822.3

822.3

EI = 0.4EcIg / (1+d) = 0.25 EcIg


Pc = 2EI / (kLu)2

SUMMARY OF LOAD VERSUS MOMENT CAPACITIES (for ACI 318-08 10.2 & 10.3 only)
CAPACITY
AT AXIAL LOAD ONLY
AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT t = 0.002
AT BALANCED CONDITION
AT t = 0.005
AT FLEXURE ONLY
AT TENSION ONLY

Pn (kips)
1739
1739
1384
1148
941
605
585
258
0
-1097

Mn (ft-kips)
0
281
487
580
648
743
751
943
822
0

__
Page 106 of 533
524

Mu =

0.3

ft-kips

Pn (kips)

(cont'd)

2000

1500

1000

500

0
0

100

200

300

400

500

600

700

800

900

1000

Mn (ft-kips)

-500

-1000

-1500

All load points to be within capacity diagram.

[Satisfactory]

DETERMINE INDUCED MOMENT IN THE COLUMN

where

3 E c I c u
h2

+ P =

E c = 57000 (fc')

0.5

168.0906 ft-kips
3824

ksi, ACI 318-08 8.5.1

I g = c1 c2 / 12 =

27648

in4

Ic =

0.7

Ig =

19354

Cd =

5.0

in4 , ACI 318-08 9.5.2.3 & 10.11.1

xe =

0.1

I =

1.0

in

u = Cd xe / I =
= 0.5 u =

0.50
0.25

in, ACI 318-08 21.13.3

P = 0.9 PDL =

202.5

kips, ACI 318-08 21.13.3

CHECK REQUIREMENTS OF NOT PART OF THE LATERAL RESISTING SYSTEM


M u = 1.2 MDL + 1.0 MLL + M =

168.0906 ft-kips
Mn =

<
Pu, max =

822.3

kips

[Satisfactory]

902.8
kips
>
0.1Agfc' =
259.2 kips
[Satisfactory]
Per ACI 318-08 21.13.4.3, the column shall satisfy ACI 318-08 21.6.3, 21.6.4, 21.6.5, and 21.7.3.1.

CHECK SECTION REQUIREMENTS (ACI 318-08 21.6.1)


cmin =MIN(c1, c2) =

24

cmin / cmax =

>

in

>

1.00

12

0.4

in

[Satisfactory]

[Satisfactory]

CHECK TRANSVERSE REINFORCING AT BOTTOM OF COLUMN (ACI 318-08 21.6.4)


in2
0.80
>
MAX[ 0.09shcfc' / fyh , 0.3shc(Ag/Ach-1)fc' / fyh ] =
Ash =
[Satisfactory]

where

0.71

s = MAX[MIN(c1/4, 6db, 4+(14-hx)/3, 6), 4] =


hc = c1 - 2Cover - dt =

20.5

Ach = (c1-3)(c2-3) =

in2

441.0

in2
5

in

CHECK FLEXURAL REINFORCING (ACI 318-08 21.6.1.1)

total = 0.040

>
<

min =
max =

0.010

[Satisfactory]

0.060

[Satisfactory]

CHECK SHEAR STRENGTH (ACI 318-08 21.6.4.6)


Ve = MAX[ (Mpr, left, top + Mpr, right,bot) / h , Vu,max] =

where

top,left =
bot,left =

0.012
0.012

Mpr, left, top =

kips
206.4

[2(fc')0.5c2d + Avfyd / s] =

kips

[Satisfactory]

205.4

kips

min=MIN[3(fc')0.5/fy, 200/fy ]= 0.003


min =
0.003
[Satisfactory]

ft-kips

Mpr, right, bot = 1.25Mn,col,max =


Vu, max =

73.4

8(fc')0.5c2d =

<
<
>
>

1028

0.033

ft-kips

[Satisfactory]

[Satisfactory]

0.75

Av =

0.8

in2

ft-kips

__

DETERMINE SEISMIC TENSION DEVELOPMENT, Ld, INTO THE FOOTING PER ACI 318-08 21.6.4.6

L dh = MAX

db f
65

'
c

, 8d b , 6 in =

L d = MAX ( 3.5 L dh , 12 in ) =
where

db

14 db

48 db

61

17

in, (ACI 318-08 21.7.5.1)

in, (ACI 318-08 21.7.5.2)

1.27

in

1.0

, (1.2 for epoxy-coated, ACI 318-08 21.7.5.4 & 12.2.4)

Page 107 of 533


524

in

(cont'd)
CHECK FLEXURE CAPACITY, AS,1, FOR STEM (TMS SEC.402 2.3.3)

M =

w Lat H
2

kd
1
t
P d e
b wkd F b d
2
3
2

M allowable = MIN
where

te
d
bw
Fb
Fs
As

M allowable

and

P =W w

1.47 ft-kips / ft

, AsF s d

0.78

kips / ft

kd
kd
t
+P e
3
2 3

<== Based on effective section area.

=
=
=
=
=
=
=

7.63
3.82
12
0.495
24
0.66
0.014

in ,
in ,
in
ksi
ksi
in2

1.59 ft-kips ,

<== Based on TMS 402-08, 1.13.3.5


Em
=
1350
Es
=
29000
n
=
21.48
k
=
0.54
>

ksi
ksi

[Satisfactory]

CHECK SHEAR CAPACITY FOR MASONRY STEM (TMS SEC.402 2.3.5)

V = H Lat

0.33 kips / ft

V allow able = d bwMIN

'
m

, 50

1.77

kips / ft

>

[Satisfactory]

CHECK FLEXURE CAPACITY, AS,3, FOR FOOTING (ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

MAX =

0.85 1 f c'

fy

u +t

(L t)
M u ,3 =

(L t)
4

0.5 W s +

(L t)

0.5 W s +

(L t)

'

0.85 f c 1 1

f
where

d
eu
S

( A S, 3 ) required

2L
2L

MIN =

0.015

(q

u ,3

+ 2q u ,heel ) b L t
2
6

q u ,3b S 2
6

M u ,3
'
0.383b d 2 f c

, for e u >

, for e u

0.00045

qu, toe
qu, heel
qu, 3

=
=
=

0.001

L
6

L
6

0.0018 h f
2
d

2.534 ft-kips

=
=
=

10.19 in
1.49 ft
-1.29 ft
in2 / ft

0.13

<

A S, 3 =

4.90
n/a
-7.99

ksf
ksf
ksf

0.21

in2 / ft

[Satisfactory]

CHECK FLEXURE CAPACITY, AS,2, FOR FOOTING (ACI 318-08 SEC.15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, & 12.5)
'

MAX =

M u ,2 =

0.85 1 f c

f y

u +t

(q

u ,4

+ 2q u ,toe ) b L t
2
6

'

0.85 f c 1 1

W f L t
2L

MIN = MIN

0.015

1.80

ft-kips

__

M u ,2
'
0.383b d 2 f c

4
0.0018 h f
,
d
3
2

0.00044

Page 108 of 533


524

where

d
qu, 4

=
=

8.69 in
-3.86 ksf

0.001

(cont'd)
( A S, 2 ) required

0.06

in2 / ft

<

A S, 2 =

0.21

in2 / ft

[Satisfactory]

CHECK SLIDING CAPACITY (IBC 09 1807.2.3, CBC 07 1806A.1)


1.5 (HLat ) =

0.49 kips / ft
<
[Satisfactory]

Hp + W =

__
Page 109 of 533
524

1.27

kips / ft

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Fixed Moment Condition Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
COLUMN SHAPE (Tube, Pipe, or WF) & SIZE

W24X192

CONCRETE STRENGTH

< ==

fc' =

ksi

FACTORED SHEAR LOAD

Vu =

205

kips

FACTORED MOMENT

Mu =

750

ft-kips

FACTORED VERTICAL LOAD (negative for uplift)

Pu =

691

kips

D=

48

in

EMBEDMENT DEPTH

bf

25.5

56.3

13.0

W Shape

THE FIXED MOMENT DESIGN IS ADEQUATE.


( Avf =

in , Required Area of Shear Studs or Welded Reinforcement)

16.0

( Edge of Concrete Footing / Grade Beam must be wider than "bf")

ANALYSIS
CHECK BASE FLEXURAL & SHEAR CAPACITY (ACI 318-08 Sec 9 & Sec 10)
700
600
Vn (k)

500

400
300
200

100
0
0

500

1000

1500

2000

Mn (ft-k)

o =

2 f C'
Ec

A2 , 2
A1

0.85Min

1103

>

u =

Vn,max =

611.08

>

Vu =

ft-kips @ Vu =
750

0.85Min

A2
, 2 f C' 2 c c
o
o
A1

0.85Min

A2
, 2 f C' , for c o
A1

fC=

Mn =

, E c = 57 f C'
, for 0 < c < o

where

205

kips, when C =

33.0 in

205

[Satisfactory]

ft-kips

=
0.65
, (ACI 318-08 Sec 9.3.2.4)
Bearing factor = 2, (ACI 318-08 Sec 22.5.5)
b = effective bearing width = 95% bf =

CHECK VERTICAL CAPACITY


Pn = End Bering + Friction =
where

1295.4

>

kips

End Bering = 0.65 (2) 0.85 fc' A =

186.6

56

fy =

60

kips

[Satisfactory]

kips, (ACI 318-08 Sec 11.7.5)

2
in , end bearing area

Ac = 0.5 (2d + 2bf ) D =


Avf = Pu,Friction / ( fy ) =
0.75
where =
=
0.70

691

kips, (ACI 318-08 Sec 22.5.5)

__

Friction = 0.75 MAX( 0.2fc' Ac , 800 Ac ) = 1108.8


A=

Pu =

1848

2
in , (0.5 for concrete cracked)

2
in , Required Area of Shear Studs or Welded Reinforcement
16.0
, (ACI 318-08 Sec 9.3.2.3)
, (ACI 318-08 Sec 11.7.4.3)

ksi, use 30% fy for DSA / OSHPD seismic shear studs (CBC 07 2204A.1.2).

Page 110 of 533


524

kips

ft-kips
[Satisfactory]

12.35

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Concrete Floodway Design Based on ACI 350-06 & ACI 318-08


INPUT DATA & DESIGN SUMMARY
fc'

ksi

REBAR YIELD STRESS

fy

60

ksi

LATERAL SOIL PRESSURE

Pa

45

pcf

CONCRETE STRENGTH

(equivalent fluid pressure)


BACKFILL WEIGHT

110

pcf

SURCHARGE WEIGHT

ws

50

psf

SEISMIC GROUND SHAKING


PE
=
20
psf /ft, ASD
(soil pressure, if no report 35SDS suggested. )
CHANNEL DEPTH
H
=
6
ft
tw

THICKNESS OF WALL
THICKNESS OF SLAB
#

SLAB TRANS REBARS

in

ts

in

10

in o.c. at mid

WALL VERTICAL REBARS


#
5
@
WALL BAR LOCATION (1=at middle, 2=at each face)

8
1

LAP LENGTH

Ls

36

in

SLAB THICKER DISTANCE

ft

in o.c.
at middle
[THE CHANNEL DESIGN IS ADEQUATE.]

ANALYSIS
DESIGN CRITERIA
1.
THE CRITERICAL DESIGN, FOR REBAR AT MIDDLE OR EQUAL OF EACH FACE, IS CHANNEL WALL AT INWARD
SOIL PRESSURE BEFORE RESTRAINED AT TOP AND CHANNEL FILLED.
2.
SINCE THE WALL AXIAL LOAD SMALL AND SECTIONS UNDER TENSION-CONTROLLED (ACI 318-08, 10.3.4), ONLY
CHECK WALL FLEXURAL CAPACITIES ARE ADEQUATE.
SINCE THE SLAB AT FLEXURAL & AXIAL LOADS, THE COMBINED CAPACITY OF FLEXURAL & AXIAL MUST BE CHECKED.
3.
SERVICE LOADS
Hb = 0.5 Pa (H + ts)2

=
=
=

Hs = ws Pa (H + ts) / b
2
HE = 0.5 PE (H + ts)

0.95

kips / ft

0.13

kips / ft

0.42

kips / ft

FACTORED LOADS
Hb = 1.6 Hb

=
=
=

Hs = 1.6 Hs
HE = 1.6 HE

1.52 kips / ft
0.21 kips / ft
0.68 kips / ft

CHECK WALL FLEXURE CAPACITY (ACI 318-08, 15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, & 12.5)
Mu = (0.5 Hs + 0.33 Hb + 0.67 HE) H =

6.38

Pu =

1.19

kips / ft, (concrete wall self weight)

d =

4.00

in,

M n = AS f
ProvD =

0.010

b =

AS f y P u
1.7bf c'
<
>

MAX =
MIN =

12
=

7.46

0.015
0.004

in,

ft-kips / ft, (entire lateral loads used conservatively)

As =

0.465

ft-kips / ft

>

in / ft

Mu

[Satisfactory]

[Satisfactory]

__

CHECK WALL SHEAR CAPACITY (ACI 318-08, 15.5.2, 11.1.3.1, & 11.2)
Vu = Hs + Hb + HE =

V n = 2 bd

'
c

2.41

kips / ft, (entire lateral loads used conservatively)

3.94

kips / ft

Page 111 of 533


524

>

Vu

[Satisfactory]

(cont'd)
CHECK SLAB COMBINED CAPACITY OF FLEXURE & AXIAL (ACI 318-08, 10)
ProvD =

< MAX = 0.08 (for compression, ACI 318-08, 10.9.1)


> MIN = 0.00333 (for flexural, ACI 318-08, 10.5.1)
[Satisfactory]
0.01033

120.0
AT AXIAL LOAD ONLY
AT MAXIMUM LOAD
AT MIDDLE
AT t = 0.002
AT BALANCED

100.0
80.0
Pn (k)

60.0

Pn

Mn

106.6
106.6
60.9
15.3
14.4

0.0
3.9
7.2
5.5
5.4

AT t = 0.005

5.3

5.3

AT FLEXURE ONLY

0.0

4.4

(Note: For middle reforming the max M n is at c

40.0

equal to 0.5 t / 1 , not at balanced condition.)


20.0
0.0
0.0

2.0

4.0

6.0

8.0

Pu =

2.41

kips / ft

Mu =

1.25

ft-kips / ft

Mn (ft-k)

[Satisfactory]

CHECK REBAR DEVELOPMENT

L d = MAX

requird 0.075 t e sd b f
provided
f c' c + K tr

, 12 in =

26 db

db

where

16

in, (ACI 318-08, 12.2.3)

<

Ls

Bar size
#
5 , (governing size)
= 0.625 in
db
1
( As,reqd / As,provd, ACI 318-08, 12.2.5)
required / provided =
t

1.0 (1.3 for bottom cover more than 12", ACI 318-08, 12.2.4)

1.0 (1.2 for epoxy-coated, ACI 318-08, 12.2.4)

0.8 (0.8 for # 6 or smaller, 1.0 for other)

=
=

1.0 (0.7 for light weight)


3.3 in, min(d' , 0.5s), (ACI 318-08, 12.2.4)

Ktr

(c + Ktr ) / db

(Atr fyt / 1500 s n) =

(ACI 318-08, 12.2.4)

2.5 < 2.5 , (ACI 318-08, 12.2.3)

__
Page 112 of 533
524

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Free Standing Masonry Wall Design Based on TMS 402-08 & ACI 318-08

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


SPECIAL INSPECTION ( 0=NO, 1=YES )

Yes

TYPE OF MASONRY ( 1=CMU, 2=BRICK )

CMU

MASONRY STRENGTH

fm '

1.5

ksi

CONCRETE STRENGTH

f c'

ksi

REBAR YIELD STRESS

fy

60

ksi

PASSIVE SOIL PRESSURE

350

pcf (equivalent fluid pressure)

ALLOW SOIL PRESSURE

Pp
Qa

FRICTION COEFFICIENT

0.35

SOIL SPECIFIC WEIGHT

Js
hp

110

pcf

12

in
psf

SOIL OVER
WALL LATERAL FORCE, ASD

ksf

wLat

36.4

HEIGHT OF STEM

ft

THICKNESS OF WALL

in

WALL VERT. REINF. (As,1)

As,1 LOCATION (1=at middle, 2=at each face)


FOOTING WIDTH

L
hf

at middle

in o.c.

3.5

ft

12

in

BOT. REINF.OF FOOTING (As,2)

18

in o.c.

TOP. REINF.OF FOOTING (As,3)

18

in o.c.

=
=
=
=
=

0.33

kips / ft

0.70

kips / ft

0.78

kips / ft

0.53

kips / ft

0.31

kips / ft

FOOTING THICKNESS

[THE WALL DESIGN IS ADEQUATE.]

ANALYSIS
SERVICE LOADS
HLat = wLat H
Hp = 0.5 Pp (hp + hf )2
W w = t H Jm
W f = hf L Jc
W s = hp (L - t) Js
FACTORED LOADS
JHLat = 1.6 HLat
JHp = 0.0 Hp
JW w = 1.2 W w
JW f = 1.2 W f
JW s = 1.2 W s

=
=
=
=
=

0.52 kips / ft
0.00 kips / ft
0.94 kips / ft
0.63 kips / ft
0.37 kips / ft

OVERTURNING MOMENT
H

JH

Hy

JH y

HLat

0.33

0.52

5.5

1.80

2.88

0.33

0.52

1.80

2.88

RESISTING MOMENT
W

JW

Wx

JW x

Ws

0.31

0.37

1.75

0.55

0.65

Wf

0.53

0.63

1.75

0.92

1.10

Ww

0.78

0.94

1.75

1.37

1.64

1.62

1.94

2.83

3.40

OVERTURNING FACTOR OF SAFETY

6Wx
6Hy

SF

1.57

>

1.5

[Satisfactory]

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)

q MAX

L 6Wx  6Hy

2
6W

6e

6W 1  L

BL

26 W
,

3
B
(0.5
L  e)

1.11

ft

>

L/4

__

L
6
L
for e !
6
for e d

1.70

ksf

Page 113 of 533


524

<

Qa

[Satisfactory]

(cont'd)
CHECK FLEXURE CAPACITY, AS,1, FOR STEM (TMS SEC.402 2.3.3)

w Lat H
2

1.47 ft-kips / ft

Ww

0.78

kips / ft

1
kd
kd

t e kd
te
MIN b wkd F b d 
 P d  , AsF s d 
 P 

2
3
2
3

2 3

M allowable
where

and

te

7.63 in ,

<== Based on effective section area.

3.82 in ,

<== Based on TMS 402-08, 1.13.3.5

bw

Em

1350

ksi

Fb

0.495 ksi

Es

29000

ksi

21.48

0.54

12

in

Fs

As

24 ksi
2
0.66 in

0.014

M allowable

1.59 ft-kips ,

>

[Satisfactory]

CHECK SHEAR CAPACITY FOR MASONRY STEM (TMS SEC.402 2.3.5)

H Lat

0.33 kips / ft

d bwMIN

V allowable

'
f m , 50

1.77

kips / ft

>

[Satisfactory]

CHECK FLEXURE CAPACITY, AS,3, FOR FOOTING (ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

U MAX

fy

Hu
Hu Ht

L  t
L t J

W
0.5J W s 
2L
4

L t
L  t
4 0.5J W s  2 L J W

M u ,3

0.85E 1 f c'

q u ,3  2q u ,heel b L t 2
L


, for e u d
6
6
2

q u ,3b S 2
L
, for e u !
f 
6
6

d
eu
S

( A S, 3 ) required

=
=
=

0.00045

10.19 in

qu, toe

1.49 ft

qu, heel

-1.29 ft

qu, 3

=
=
=

0.13

0.0018 h f
2
d

0.001

M u ,3
0.85 f c' 1  1 

2 '

0.383b d f c

fy
where

U MIN

0.015

in2 / ft

<

A S, 3 =

4.90

ksf

n/a

ksf

-7.99

ksf

0.21

in2 / ft

2.534 ft-kips

[Satisfactory]

CHECK FLEXURE CAPACITY, AS,2, FOR FOOTING (ACI 318-08 SEC.15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, & 12.5)

U MAX

M u ,2

0.85E 1 f c'
f y

u ,4

Hu
Hu Ht

U MIN

0.015

 2q u ,toe b L t 2 J W f L t 2

6
2L 2
2

1.80

0.0018 h f
4
MIN U ,
2
d
3

ft-kips

__

M u ,2
0.85 f 'c 1  1 

2 '

0.383bd f c

fy

0.00044

Page 114 of 533


524

where

d
qu, 4

=
=

8.69 in
-3.86 ksf

0.001

(cont'd)
( A S, 2 ) required

0.06

in2 / ft

<

A S, 2 =

0.21

in2 / ft

[Satisfactory]

CHECK SLIDING CAPACITY (IBC 09 1807.2.3, CBC 07 1806A.1)


1.5 (HLat ) =

0.49 kips / ft

<

Hp + P6W =

1.27

[Satisfactory]

__
Page 115 of 533
524

kips / ft

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Free Standing Concrete Wall Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH
fc'
=
=
REBAR YIELD STRESS
fy
=
PASSIVE SOIL PRESSURE
Pp
Qa
=
ALLOW SOIL PRESSURE
FRICTION COEFFICIENT

=
=
SOIL SPECIFIC WEIGHT
s
hp
=
SOIL OVER
=
WALL LATERAL FORCE, ASD wLat
HEIGHT OF STEM
H
=
THICKNESS OF WALL
t
=
#
WALL VERT. REINF. (As,1)
As,1 LOCATION (1=at middle, 2=at each face)
FOOTING WIDTH
L
=
hf
=
FOOTING THICKNESS
#
BOT. REINF.OF FOOTING (As,2)
#
TOP. REINF.OF FOOTING (As,3)

3
60
350
2
0.35
110
12
42
21
12
6
2
9
18
6
6

ksi
ksi
pcf (equivalent fluid pressure)
ksf
pcf
in
psf
ft
in
@
12
at each face
ft
in
@
18
@
18

in o.c.

in o.c.
in o.c.

[THE WALL DESIGN IS ADEQUATE.]

ANALYSIS
SERVICE LOADS
HLat = wLat H
Hp = 0.5 Pp (hp + hf )2

=
=
=
=
=

Ww = t H c
W f = hf L c
Ws = hp (L - t) s
FACTORED LOADS
HLat = 1.6 HLat
Hp = 0.0 Hp
Ww = 1.2 Ww
Wf = 1.2 Wf
Ws = 1.2 Ws

=
=
=
=
=

1.41
0.00
3.78
2.43
1.06

0.88
1.09
3.15
2.03

kips / ft
kips / ft
kips / ft
kips / ft

0.88

kips / ft

kips / ft
kips / ft
kips / ft
kips / ft
kips / ft

OVERTURNING MOMENT
H

Hy

H y

0.88
0.88
RESISTING MOMENT

1.41
1.41

12

10.58
10.58

16.93
16.93

Wx

W x

Ws
Wf
Ww

0.88
2.03
3.15
6.06

1.06
2.43
3.78
7.27

4.5
4.5
4.5

3.96
9.11
14.18
27.25

4.75
10.94
17.01
32.70

H
HLat

OVERTURNING FACTOR OF SAFETY

SF =

Wx
=
Hy

2.574
> 1.5
[Satisfactory]

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)

e=

L Wx Hy

2
W
W 1 +

q MAX =

6e
L

1.75

ft

<

L/4

__

L
, for e
BL
6
L
2W
, for e >
3B (0.5 L e)
6

1.47

ksf

Page 116 of 533


524

<

Qa

[Satisfactory]

(cont'd)
CHECK FLEXURE CAPACITY, AS,1, FOR STEM (ACI 318-08 SEC.15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, & 12.5)
ProvD = 0.00381
< MAX = 0.04 (tension face only, ACI 318-08 10.3.5 or 10.9.1)
> MIN = 0.00075 (tension face only, ACI 318-08 10.5.1, 10.5.3 or 14.3.2)
[Satisfactory]
250.0

200.0

150.0
Pn (k)
100.0

Pn

Mn

AT AXIAL LOAD ONLY


AT MAXIMUM LOAD
AT MIDDLE
AT t = 0.002
AT BALANCED

217.2
217.2
139.0
60.8
58.6

0.0
7.5
28.3
37.8
38.1

AT t = 0.005

33.8

44.6

AT FLEXURE ONLY

0.0

18.2

(Note: For middle reforcing the max M n is at c


equal to 0.5 t / 1 , not at balanced condition.)

50.0

0.0
0.0

10.0

20.0

30.0

40.0

50.0

at bottom

at middle

Pu

3.78

1.89

Mu

14.82

3.70

Mn (ft-k)

[Satisfactory]

CHECK STEM SHEAR CAPACITY (ACI 318-08 SEC.15.5.2, 11.1.3.1, & 11.2)

V u = Max. Horiz. Shear

1.41

kips / ft, at bottom

V n = 2 bd f c'

9.49

kips / ft

>

Vu

[Satisfactory]

CHECK FLEXURE CAPACITY, AS,3, FOR FOOTING (ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, & 12.5)

0.85 1 f c
'

MAX

f y

(L t)
4

M u ,3 =

(L t)
4

u +t

0.5 W s +

(L t)

0.5 W s +

(L t)

0.85 f c 1 1
'

f
where

d
eu
S

( A S, 3 ) required

2L
2L

M u ,3
'
0.383b d 2 f c

MIN =

0.015

(q

u ,3

+ 2q u ,heel ) b L t
2
6

q u ,3b S 2
6

, for e u >

0.00023

qu, toe
qu, heel
qu, 3

=
=
=

, for e u

0.0018 h f
2
d

0.001

L
6

L
6

3.02 ft-kips

=
=
=

15.63 in
2.33 ft
1.51 ft
0.19

in2 / ft

<

A S, 3 =

2.23
n/a
0.52

ksf
ksf
ksf

0.29

in2 / ft

[Satisfactory]

CHECK FLEXURE CAPACITY, AS,2, FOR FOOTING (ACI 318-08 SEC.15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, & 12.5)

0.85 1 f c
'

MAX =

f y

u
u +t

__
=

0.015

Page 117 of 533


524

MIN = MIN

4
0.0018 h f
,
3
2
d

0.001

(cont'd)

( q u ,4 + 2q u ,toe ) b L t
M u ,2 =
2
6

W f L t
2L

12.04

ft-kips
where

0.85 f c 1 1
'

=
( A S, 2 ) required

f
=

M u ,2
'
0.383b d 2 f c

d
qu, 4

0.00105

0.19

in2 / ft

<

A S, 2 =

0.29

in2 / ft

[Satisfactory]

CHECK SLIDING CAPACITY (IBC 09 1807.2.3, CBC 07 1806A.1)


1.5 (HLat ) =

=
=

1.32 kips / ft
<
[Satisfactory]

Hp + W =

3.21

__
Page 118 of 533
524

kips / ft

14.63 in
0.861 ksf

PROJECT :
CLIENT :
JOB NO. :

DATE :

Lateral Earth Pressure of Rigid Wall Based on AASHTO 17th & 2009 IBC
INPUT DATA & DESIGN SUMMARY
SOIL SPECIFIC WEIGHT

110

pcf

SOIL INTERNAL FRICTION ANGLE


SLOPE OF BACKFILL
EXTERNAL FRICTION ANGLE
RACK ANGLE OF WALL FACE

=
=
=
=

30
15
17
90

deg
deg
deg
deg

41

psf / ft

The Active Earth Pressure:

Pa

39

pcf (horizontal equivalent fluid pressure)

The At-rest Earth Pressure:

P0

55

psf / ft

The Passive Earth Pressure:

Pp

330

psf / ft

Pa, h

ANALYSIS
DETERMINE ACTIVE EARTH PRESSURE
Pa = b Ka =

41

psf / ft

Pa, h = Pa sin( - ) =

39

pcf (horizontal equivalent fluid pressure)

where

sin 2 ( + )

Ka =

sin 2 sin ( ) 1+

sin ( + ) sin ( )
sin ( ) sin ( + )

0.372

(Coulomb, AASHTO Figure 5.5.2A)


The total active resultant, (0.5 H Pa), acts H/3 above the base.

DETERMINE AT-REST EARTH PRESSURE


P0 = b K0 =

55

where K0 = 1 - sin =

psf / ft
0.500 , (AASHTO 5.5.2-2)

The total horizontal resultant at rest, (0.5 H P0), acts H/3 above the base.

DETERMINE PASSIVE EARTH PRESSURE


Pp = b Kp =

330

where K p =

1 + sin
=
1 sin

psf / ft
3.000 , (Rankine, AASHTO Figure 5.5.2D)

deg

90

deg

The total horizontal resultant at rest, (0.5 H Pp), acts H/3 above the base.

PAGE :
DESIGN BY :
REVIEW BY :

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Sheet Pile Wall Design Based on IBC 09 / CBC 10 / ACI 318-08


INPUT DATA & DESIGN SUMMARY
Hcant =

HEIGHT OF CANTILEVER

ws

SURCHARGE WEIGHT

12.5

ft

500

psf

ALLOWABLE LATERAL SOIL-BEARING PRESSURE IN EMBEDMENT


Pp

300

psf / ft

LATERAL SOIL PRESSURE

Pa

35

pcf (equivalent fluid pressure)

SEISMIC GROUND SHAKING

PE

420

psf / ft (for Hcant > 12 ft only)

SOIL SPECIFIC WEIGHT

110

pcf

CONCRETE STRENGTH

fc'

ksi

VERT. REBAR YIELD STRESS

fy

60

PILE DIAMETER
D
=
PILE SPACING
S
=
PILE VERT. REINF.
16 #
LATERAL REINF. OPTION (0=Spirals, 1=Ties)
LATERAL REINFORCEMENT
#
5 @

42
3.85
11
1
6

ksi
in
ft, o.c.
Ties
in o.c.

THE SHORING DESIGN IS ADEQUATE.


( H embd =

24.80

ft. Min. Req'D)

ANALYSIS
DETERMINE PILE SECTION FORCES AT CANTILEVER BOTTOM
Hb = 0.5 S Pa (Hcant)2 =

10.53

Hs = ws S Pa (Hcant) / b =

7.66

kips, ASD

HE = 0.5 S PE (Hcant)2 =

126.33

kips, ASD

kips, ASD

P = S D ws + 0.25 c D2 Hcant =

24.78

kips, ASD

V = Hb + HE + Hs =

144.51

kips, ASD

M = (Hb /3 + 2HE /3 + Hs /2 ) Hcant =

897.2

ft-kips, ASD

Pu = 1.2 P =

29.73

kips, SD

Vu = 1.6 V =

231.22

kips, SD

Mu = 1.6 M =

1435.5

ft-kips, SD

CHECK PILE LIMITATIONS


fc' =
D=

4
42

ksi
in

>
>

4
ksi
MAX[( Hcant + Hembd) / 30 , 12 in]

[Satisfactory] (IBC 09 Table 1808.8.1)


[Satisfactory] (IBC 09 1810.3.5.2)

CHECK FLEXURAL & AXIAL CAPACITY

o =

Pmax =F [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

=
=

Ag =

'
C

, E c = 57

Ec
0.85 f

'
C

0.85 f

'
C

sEs ,
f y ,

c c
o
o

, E s = 29000ksi

'
C

for 0 < c < o

for c o
for s y

for s > y

3184.1 kips., (at max axial load, ACI 318-08, Sec. 10.3.6.2)

0.8 , ACI 318-08, Sec. 10.3.6.1 or 10.3.6.2


0.65 (ACI 318-08, Sec.9.3.2.2)
2
1385 in .

2 0.85 f

Ast =

>
2
24.96 in .

Pu

[Satisfactory]

(cont'd)
3500
3000
2500

AT COMPRESSION ONLY
AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT t = 0.002

2000
1500

Pn (k)

1000
500
0
-500 0

500

1000

1500

2000

Pn (kips)
3184
3184
2807
2333
1921
1300

Mn (ft-kips)
0
807
1169
1495
1679
1831

1272
483

1854
2127

AT BALANCED CONDITION
AT t = 0.005

2500

-1000

AT FLEXURE ONLY

1598

-1500

AT TENSION ONLY

-1348

-2000

Mn (ft-k)
a = Cb 1 =

19

in (at balanced strain condition, ACI 10.3.2)

0.75 + ( t - 0.002 ) (200 / 3), for Spiral

0.65 + ( t - 0.002 ) (250 / 3), for Ties


where

Cb = d c / ( c + s) =
d

22

0.656

in

37.7 in, (ACI 7.7.1)

(ACI 318-08, Fig. R9.3.2)

t =

0.002069

1 =

0.85

c =

0.003

( ACI 318-08, Sec. 10.2.7.3 )

Mn = 0.9 n =

1598 ft-kips @ Pn = 0, (ACI 318-08, Sec. 9.3.2) ,& et,max = 0.004, (ACI 318-08, Sec. 10.3.5)

Mn =

ft-kips @ Pu =

1631

30

>

kips

max

0.08 (ACI 318-08, Section 10.9)

min

0.005 (IBC 09 1810.3.9.4.2)

provd

Mu

[Satisfactory]

0.018
[Satisfactory]

CHECK SHEAR CAPACITY

Vn = (Vs + Vc) =
where

281 kips, (ACI 318-08 Sec. 11.1.1)

> Vu
[Satisfactory]
0.75 (ACI 318-08 Sec. 9.3.2.3)

2
1115 in .

A0 =

smax
smin
s =

Av =

Vc =

2 (fc')0.5A0 =

Vs =

MIN (d fy Av / s , 8 (fc')0.5A0) =

12

0.62

in2.

fy =

sprovd

s,provd =

By trials, use pole depth, d = H embd =

0.008 [Satisfactory]

7.20

ksf

Lateral bearing @ d / 3, S 1 = 2 P p Min( d / 3 , 12' ) =


Require Depth is given by

4.96

ksf

for nonconstrained

P= V =

in

(ACI 318-08 Sec. 21.12.4.4 & 21.6.4.1)

24.80 ft

Lateral bearing @ bottom, S 3 = 2 P p Min( d , 12' ) =

Where

[Satisfactory]

<

0.12 fc' / fyt = 0.008

A
4.36h
1+ 1+
2
A

ksi

233.6 kips, (ACI 318-08 Sec. 11.4.7.2 & 11.4.7.9)

(IBC 09 1810.3.9.4.2)

DETERMINE PILE EMBEDMENT LENGTH, H embd , (IBC 09 1807.3)

d =

60

141.0 kips, (ACI 318-08 Sec. 11.2.1, 11.2.1.3)

144.51 kips

A = 2.34 P / (D S 1 ) =

19.48

h= M /V =

ft

6.21

24.80 ft

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Composite Element Design Based on AISC 360-05 & ACI 318-08


INPUT DATA & DESIGN SUMMARY
f c'

CONCRETE STRENGTH
REBAR STEEL YIELD STRESS

ksi

fy, Bar =

60

ksi

VERTICAL REINFORCING
COVER TO VERTICAL REBAR

Cc

3.25

in

fy, WF =
50 ksi
W16X67

WF STEEL YIELD STRESS


WF SECTION
tf

bf

tw

0.665

10.2

0.395

16.3

19.7

ELEMENT DIAMETER

FACTORED AXIAL LOAD

Pu

-500 k, tension

Mu,x

600

ft-k

Mu,y

200

ft-k

Vu,x

68

Vu,y

50

FACTORED MOMENT

FACTORED SHEAR LOAD

30

in

THE SECTION DESIGN IS ADEQUATE.

ANALYSIS
2000
1500

1000

Pn (k)

500
0
0

200

400

600

800

1000

1200

-500
-1000
-1500

Mn (ft-k)

Capacity Drawings
AT AXIAL LOAD ONLY
AT MAXIMUM LOAD
AT 75% MAXIMUM LOAD
AT 50% MAXIMUM LOAD
AT 25% MAXIMUM LOAD
AT FLEXURE ONLY
AT STEEL STRAIN 0.005
AT AXIAL LOAD -715 k
AT PURE TENSION

Pn (k)
1394
1394
1045
697
348
0
-202
-715
-1228

0.75
0.75
0.75
0.81
0.84
0.87
0.9
0.9
0.9

Mn (ft-k)
0
894
922
1017
1052
1084
1110
721
0

o =

2 0.85 f

'
C

Ec

0.85 f
=

0.85 f

'
C

, E c = 57

1394

'
C

, for c o
,
for s t

s E s
=
,
for
f
s >t

>
where

kips, (AISC 360-05 I2-2 & I2-3)

Pu

[Satisfactory]

0.75

(AISC 360-05 I2.1b & ACI 318-08 9.3.2.2)

Ac

707

in2

Ic

39642

in4

6.32

in2

Is

119

in4

As, Bar

'
C

2
2 c c ,
o o

CHECK FLEXURAL & AXIAL CAPACITY

Pmax = c Pn =

, E s = 29000ksi
for 0 < c < o

(cont'd)

Balanced :

C1

0.154

KL

30

Pe

2139

kips, (AISC 360-05 I2-5)

0.75

(AISC 360-05 I2.1b & ACI 318-08 Fig. R9.3.2)

, (AISC 360-05 I2-7)

16.7

884

28093060

Po

4368

t, min =

in

26.3 in, (ACI 7.7.1)

Critical Points
AT AXIAL LOAD ONLY
AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT STEEL STRAIN 0.002
AT BALANCED CONDITION
AT STEEL STRAIN 0.005
AT FLEXURE ONLY

Mn =

ksi-in4, (AISC 360-05 I2-6)

ft, effective length

Cb = d c / (c + s) =
d

E Ieff

-500 kips

30.0

>

Mu =

632

Mn (ft-k)
0
894
650
781
859
933
925
1110
1084
ft-kips
provd

max

0.08 (ACI 318-08 10.9)

min

0.01 (AISC 360-05 I2.1a & ACI 318-08 10.9)

0.003

in

Pn (k)
1394
1394
2174
1853
1577
984
1117
-202
0

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.9
0.8736

ft-kips @ Pu =

c =

0.0017

D =

kips, (AISC 360-05 I2-4)

[Satisfactory]
=

0.037
[Satisfactory]

CHECK SHEAR CAPACITY (AISC I2.1d & ACI 318-08 11.1 & 11.2)

Vnx = (Vcx)

>

Vux

(ACI 318-08 11.1.1)

v Vny = v (Vny)

>

Vuy

(AISC 360-05 G2.1)

where

=
v =

x
y

[Satisfactory]

0.75 (ACI 318-08 9.3.2.3)


1.00 (AISC 360-05 G2.1)
d

A0

26
10

656

Aw

Vc =

2 (fc')0.5A0

Vn = 0.6 fy Aw Cv

92.8
14

407.0

Vn
70
407

Note:
1.
The minimum Stud Shear Connectors (not shown on this spreadsheet) are 3/4" @ 12" O.C. in both directions of vertical and horizontal
around WF steel shape. (AISC 360-05 I2.1g)

PROJECT :
CLIENT :
JOB NO. :
DATE :
Seismic Design for Special Moment Resisting Frame Based on ACI 318-08

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY

D =

CONCRETE STRENGTH

fc' =

ksi

DISTRIBUTED UNFACTORED LOADS

REBAR YIELD STRESS


BEAM LENGTH BET. COL. CENTERS
BEAM SIZE

fy
L
b
h
c1

60
25
24
36
36

ksi
ft
in
in
in

L =
0.6
kips / ft
SECTION MOMENTS & SHEARS AT FACE OF COL. (ft-kips, kips)
MA
VA
MB
VB
D
-130
45
-180
-45
L
-25
7
-25
-7

24

in

COLUMN SIZE

=
=
=
=
=

c2 =
SDS =
=

SEISMIC PARAMETER
REDUNDANCY FACTOR
LONGITUDINAL REINFORCING
SECTION
TOP
9
(d =
BOTTOM

A
#
33.31
( 1 Layer)
5
#
( d = 33.31
( 1 Layer)

QE

B
#
33.31
( 1 Layer)
5
#
( d = 33.31
( 1 Layer)

3
(d =

9
in )

61

-665

kips / ft

-61

0.44
1.15
MID SPAN
#
9
33.31 in )
( 1 Layer)
5
#
9
( d = 33.31 in )
( 1 Layer)

9
in )

665

4.1

9
(d =

9
in )
9
in )

HOOP & STIRRUP LOCATIONS (ACI 21.5.3)


AT END, S1
AT MID, S2
AT SPLICE, S3
LOCATION
LENGTH
72
in
120
in
48
in
(L-4h-c1)
( 2h )
1.3 MAX{0.075fy t b sdb/[(fc')0.5(c+Ktr)/db], 12}
TYPE
Hoops
Stirrups
Hoops
BAR
5 Legs # 5
3 Legs # 5
5 Legs # 5
(Legs to alternate long bars supported, ACI 7.10.5.3)
SPACING
@ 8 in o.c.
@ 16 in o.c.
@ 4 in o.c.
MIN(d/4, 8db, 24dt, 12)
( d/2 )
MIN(d/4, 4)

THE BEAM DESIGN IS ADEQUATE.


ANALYSIS
DESIGN LOADS
U = (1.2+0.2SDS)D + QE + 1.0L
(ACI 9-5)
AT SECTION A, FACE OF COLUMN
Vu =

135.1

kips

Mu =

572.3

ft-kips

or

AT SECTION B, FACE OF COLUMN


-5.2

kips

Vu =

or
-957.2 ft-kips
AT MIDDLE OF THE SPAN

Mu =

Vu =

0.0

kips

or

0.0

Mu =

131.1

ft-kips

or

131.1

or

-33.6

kips

U = (0.9-0.2SDS)D + QE
(ACI 9-7)
AT SECTION A, FACE OF COLUMN
Vu =

106.7

kips

Mu =

659.2

ft-kips

Vu =

65.2

Mu =

-196.0

kips
ft-kips

kips

or

5.2

or

507.9

kips
ft-kips

kips
ft-kips

AT SECTION B, FACE OF COLUMN

or
-870.3 ft-kips
AT MIDDLE OF THE SPAN

Vu =

-106.7

kips

or

33.6

kips

Mu =

-910.9

ft-kips

or

618.6

ft-kips

Vu =

0.0

kips

or

0.0

kips

Mu =

75.6

ft-kips

or

75.6

ft-kips

__

U = 1.2D + 1.6L
(ACI 9-2)
AT SECTION A, FACE OF COLUMN

-135.1

-1021.6 ft-kips

AT MIDDLE OF THE SPAN


Vu =

0.0

Mu =

129.8

Page 119 of 533


524

AT SECTION B, FACE OF COLUMN

kips

Vu =

-65.2

kips

ft-kips

Mu =

-256.0

ft-kips

cont'd
CHECK SECTION REQUIREMENTS (ACI 21.5.1)
Pu < 0.1Agfc'
[Satisfactory]
Lu=L-c1 =

22.00

b/h=
b =

0.67
24

>

ft

>

0.3

>
<

in

4d=

11.10

[Satisfactory]
10
in
c2+1.5h =
78

ft

[Satisfactory]

[Satisfactory]
in
[Satisfactory]

CHECK FLEXURAL REQUIREMENTS


AT SECTION A, FACE OF COLUMN
(ACI 21.5.2.1)

(ACI 21.5.2.2)

top =

0.011

bot =

0.006

Mn,bot

>

>
<
>
<

min=MIN[3(fc')0.5/fy, 200/fy ]=
0.003
max =
0.025
[Satisfactory]
min =
0.003
[Satisfactory]
max =
0.025
[Satisfactory]

(1/2)Mn,top

[Satisfactory]

Mn,bot = bot bd fy (1 - 0.588bot fy/fc') =

772

ft-kips

Mn,top = top bd fy (1 - 0.588top fy/fc') =


=
0.9
AT SECTION B, FACE OF COLUMN

1301

ft-kips

where

2
2

(ACI 21.5.2.1)

top =
bot =

(ACI 21.5.2.2)

AT MIDDLE OF THE SPAN


(ACI 21.5.2.1) top =

bot =
(ACI 21.5.2.2)

0.006

>

Mn,bot
where

min =
max =
min =
max =

(1/2)Mn,top

0.003

[Satisfactory]

0.025

[Satisfactory]

0.003

[Satisfactory]

0.025

[Satisfactory]

Mn,bot = bot bd fy (1 - 0.588bot fy/fc') =

772

ft-kips

Mn,top = top bd2fy (1 - 0.588top fy/fc') =

1301

ft-kips

>
<
>
<

0.004
0.006

>
>

Mn,bot

min =
max =
min =
max =

0.003

[Satisfactory]

0.025

[Satisfactory]

0.003

[Satisfactory]

0.025

[Satisfactory]

(1/4)Mn,max

[Satisfactory]

(1/4)Mn,max

[Satisfactory]

Mn,top = top bd2fy (1 - 0.588top fy/fc') =

478

ft-kips

2
Mn,bot = bot bd fy (1 - 0.588bot fy/fc') =

772

ft-kips

Mn,max =

1301

>
>

Mu /

[Satisfactory]

Mu /

[Satisfactory]

>
>

Mu /

[Satisfactory]

Mu /

[Satisfactory]

>
>

Mu /

[Satisfactory]

Mu /

[Satisfactory]

[Satisfactory]

Mn,top
where

>
<
>
<

0.011

[Satisfactory]

ft-kips

CHECK SHEAR STRENGTH (ACI 21.5.4)


FOR SEISMIC LOAD ACTING TO THE LEFT
Ve = (Mpr, A, top + Mpr, B,bot) / Ln + VgL =
Ve - dwu = 162.4
where

<

kips

Ve - (2h + d)wu =

178.7

127.1
0.5

Vc = 2(fc') bd =

[Vc + Avfyd/s1 ] =

<

kips
0.0

290.4

8(fc')0.5bd =
kips

[2(fc')0.5bd + Avfyd/s2 ] =

kips, (Per ACI 21.5.4.2, Vc = 0, if (Ve -VgL)

Mpr, A, top = top bd2fy (1.25 - 0.919top fy/fc') =

1564

ft-kips

Mpr, B ,bot = bot bd2fy (1.25 - 0.919bot fy/fc') =

945

ft-kips

Ln = L - c1 =

22.0

wu = (1.2+0.2SSD)D+1.0L =
VgL = wuLn / 2 =
=
0.75

5.9

kips

Ve - (2h - d)wu =

110.8

kips

0.93

178.7

<

Ve - dwu = 162.4

kips

[Satisfactory]

152.8

kips

[Satisfactory]

50% Ve AND Pu < Ag fc' / 20 )

kips / ft, (for CBC, only D + L, without factor)

64.7
kips
(ACI 9.3.2.3)
in2 @ end ,

Ve = (Mpr, A, bot + Mpr, B,top) / Ln + VgL =

262.7

[Satisfactory]

ft

1.55
Av =
FOR SEISMIC LOAD ACTING TO THE RIGHT

where

<

kips

in2 @ mid of beam

<

kips

[Vc + Avfyd/s1 ] =

<

290.4

8(fc')0.5bd =
kips

[2(fc')0.5bd + Avfyd/s2 ] =

Mpr, A ,bot = bot bd fy (1.25 - 0.919bot fy/fc') =

945

Mpr, B, top = top bd2fy (1.25 - 0.919top fy/fc') =

1564

ft-kips

__
Page 120 of 533
524

ft-kips

262.7

kips

[Satisfactory]

[Satisfactory]
152.8

kips

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Seismic Design for Special Moment Resisting Frame Based on ACI 318-08

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

fc ' =

ksi

REBAR YIELD STRESS

fy =

60

ksi

COLUMN CLEAR HEIGHT

Hn =

10.17

ft

COLUMN SIZE

c1 =

36

in

c2 =

36

in

SDS =
=

SEISMIC PARAMETER
REDUNDANCY FACTOR

0.44
1.15

SECTION MOMENTS & SHEARS AT END OF COL. (ft-kips, kips)


Mtop
Mbot
P
V
D
692
-4
-20
-2
L
87
-1
-1
-1
QE

900

93

LONGITUDINAL REINFORCING
SECTION
LEFT
6
(d =

TOP
#
8
33.38 in )
( 1 Layer)
6
#
8
( d = 33.38 in )
( 1 Layer)
20
#
8
( 8 # 8 at sides )

RIGHT

TOTAL
BARS

500

BOTTOM
#
8
33.38 in )
( 1 Layer)
6
#
8
( d = 33.38 in )
( 1 Layer)
20
#
8
( 8 # 8 at sides )

6
(d =

TRANSVERSE REINFORCEMENT FOR CONFINEMENT (ACI 21.6.4 & 21.6.3)


LOCATION
AT END, Lo
AT MID
LENGTH
36
in
4 in + 4 in

AT SPLICE, S
43
in

1.3Max{(0.075)fydb/[(fc')0.5(c+Ktr)/db],12}
MAX( c1, Hn/16, 18)
Hoops
Hoops
Hoops
4 Legs # 5
4 Legs # 5
4 Legs # 5
(Legs to alternate long bars supported, ACI 7.10.5.3)
@ 4 in o.c.
@ 6 in o.c.
@ 4 in o.c.

TYPE
BAR SIZE
SPACING

MIN{c1/4, 6db, MAX[MIN(4+(14-hx)/3, 6), 4]}

MIN( 6db, 6 )

Same as END Lo

THE COLUMN DESIGN IS ADEQUATE.


ANALYSIS
DESIGN LOADS
U = (1.2+0.2SDS)D + QE + 1.0L
Pu =

980.6

U = (0.9-0.2SDS)D + QE

(ACI 9-5)

(ACI 9-7)

kips

Mu,top =

1028.8

ft-kips

Pu =

564.2

kips

Mu,top =

1031.8

ft-kips

Vu =
80.2
kips
U = 1.2D + 1.6L
(ACI 9-2)

Mu,bot =

571.4

ft-kips

Vu =

90.7

kips

Mu,bot =

573.4

ft-kips

Pu =

969.6

kips

Mu,top =

-6.4

ft-kips

Vu =

-25.6

kips

Mu,bot =

-4.0

ft-kips

CHECK SECTION REQUIREMENTS (ACI 21.6.1)


Pu =

564.2

cmin =MIN(c1, c2) =


cmin / cmax =

>

kips
36

in

>

1.00

0.1Agfc' =

388.8

>

12

0.4

kips

[Satisfactory]

in

[Satisfactory]

[Satisfactory]

CHECK TRANSVERSE REINFORCING AT END OF COLUMN (ACI 21.6.4)


in2
Ash =
1.24
>
MAX[ 0.09shcfc' / fyh , 0.3shc(Ag/Ach-1)fc' / fyh ] =
[Satisfactory]

where

0.73

s = MAX[MIN(c1/4, 6db, 4+(14-hx)/3, 6), 4] =

__
hc = c1 - 2Cover - dt =

32.4

Ach = (c1-3)(c2-3) =

in2

1089.0

in

CHECK FLEXURAL REINFORCING (ACI 21.6.3.1)


AT TOP SECTION

total = 0.013

>

min =

Page 121 of 533


524

0.010

[Satisfactory]

in2
5

in

(cont'd)
AT BOTTOM SECTION

total = 0.013

>

min =

0.010

[Satisfactory]

AT SPLICE SECTION

total = 0.026

<

max =

0.060

( 0.030 should be used for lap splice existed.)

[Satisfactory]
CHECK CAPACITY SUBJECTED TO BENDING AND AXIAL LOAD
APPLIED LOADING (ACI 10.12.3)
LOADS
1
2

980.6

564.2

564.2

969.6

969.6

1028.8

571.4

1031.8

573.4

6.4

4.0

1.018

1.018

1.011

1.011

1.018

1.018

Pu (kips)

980.6

Mu (ft-kips)

ns = Cm/[1-Pu/(0.75Pc)]
nsMu (ft-kips)
Mn (ft-kips) @ Pu

1047.8

581.9

1042.6

579.4

6.5

4.1

1325.3

1566.8

1293.9

1564.8

1104.9

1103.0

EI = 0.4EcIg / (1+ d) = 0.25 EcIg

where

Pc = EI / (kLu)
2

SUMMARY OF LOAD VERSUS MOMENT CAPACITIES (ACI 10.2 & 10.3)


Pn (kips)
2191
2191
1959
1647
1392
1008
987
687
0

CAPACITY
AT AXIAL LOAD ONLY
AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT t = 0.002
AT BALANCED CONDITION
AT t = 0.005
AT FLEXURE ONLY

Mn (ft-kips)
0
568
805
1028
1162
1307
1318
1651
1100

Pn (kips)
2500

2000

1500

1000

500

Mn (ft-kips)

0
0

200

400

600

800

1000

1200

1400

1600

1800

All load points to be within capacity diagram.

[Satisfactory]

CHECK SHEAR STRENGTH (ACI 21.6.5)


Ve = MAX[ (Mpr, left, top + Mpr, right,bot) / Hn , Vu,max] =

where

top,left =
bot,right =

0.004
0.004

<
<
>
>

246.7

8(fc')0.5c2d =

kips
394.9

[2(fc')0.5c2d + Avfyd/smid ] =

kips

[Satisfactory]

409.1

kips

min=MIN[3(fc') /fy, 200/fy ]=


0.003
min =
0.003
[Satisfactory]
0.5

[Satisfactory]

[Satisfactory]

Mpr, left, top = MIN [1.25Mn,col,max , 0.5 (Mpr,top beam, left + Mpr,top beam, right) ] =

1254

ft-kips

Mpr, right, bot = MIN [1.25Mn,col,max , 0.5 (Mpr,bot beam, left + Mpr,bot beam, right) ] =
=
0.75
(ACI 9.3.2.3)
in2
Av =
1.24

1254

ft-kips

__
Page 122 of 533
524

PROJECT :
CLIENT :
JOB NO. :
DATE :
Seismic Design for Special Moment Resisting Frame Based on ACI 318-08

PAGE :
DESIGN BY :
REVIEW BY :

CHECK STRONG COLUMN - WEAK BEAM (ACI 21.6.2.2)


Mc = Mn,top @ Pu, top + Mn,bot @ Pu, bot =

>
where

1.2Mg = 1.2(Mn,top + Mn,bot) =


Mn,top @ Pu, top =
Mn,bot @ Pu, bot =
Mn,top =

1300.5

Mn,bot =

771.5

4077.7

ft-kips

2486.5

ft-kips

2038.9

ft-kips

2038.9

ft-kips

Mn,top @ Pu, top


[Satisfactory]
Mn,top

Mn,bot

ft-kips, (slab bars included, ACI 318-08)


ft-kips

Note: For UBC 97, Mc & Mg shall be at the center of the joint with factors,
which means Mc > (0.9/0.7)1.2Mg.

Mn,bot @ Pu, bot

CHECK JOINT CAPACITY (ACI 21.7)


Ve = 1.25fy(As,top + As,bot) - (Mpr,top + Mpr,bot)/Hn =
where

As,top =

9.00

in2

As,bot =

5.00

in2

Mpr,top =

1563.6

Mpr,bot =

945.2

ft-kips

Hn =

10.17

ft

Vn = k Aj (fc')0.5 =
where

804.5

Aj = c1 MIN(b+c1 , c2) =
k=

20
0.85

803.3

kips
As,top

ft-kips
Mpr,top

>

kips

Ve

Mpr,bot

[Satisfactory]

in2

864

(20 for four faces, 15 for three faces, & 12 for others)
(ACI 9.3.4 c)

As,bot

THEJOINT DESIGN IS ADEQUATE.


Technical References:
1. Alan Williams: "Seismic and Wind Forces, Structural Design Examples", International Code Council, 2003.
2. SEAOC: "2000 IBC Structural/Seismic Design Manual - Volume 3", International Code Council, 2003.
3. David A. Fanella: "Design of Concrete Buildings for Earthquake and Wind Forces", Portland Cement Association, 1998.

__
Page 123 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Special Reinforced Concrete Shear Wall Design Based on ACI 318-08 / IBC 09
INPUT DATA

DESIGN SUMMARY

CONCRETE STRENGTH (ACI 318 5.1.1)

f c'

ksi

SHEAR WALL LENGTH

28.83 ft

REBAR YIELD STRESS

fy

60

ksi

SHEAR WALL THICKNESS


BULB END WIDTH

t
B

=
=

16.00 in
34.00 in

FACTORED AXIAL LOAD

Pu

D + Web

173.71 in

FACTORED MOMENT LOAD

Mu

= 87822 ft-k

BULB REINFORCING

28

11

FACTORED SHEAR LOAD

Vu

LENGTH OF SHEAR WALL


THICKNESS OF WALL
DEPTH AT FLANGE
WIDTH AT FLANGE

L
t
D
B

= 28.83 ft
=
16 in
=
34 in
=
34 in

WALL HORIZ. REINF


WALL VERT. REINF
HOOP REINF - WIDTH, B, DIR.
HOOP REINF - LENGTH DIR.

2
2
5
22

#
#
#
#

7
7
5
5

TOTAL WALL HEIGHT TO TOP


REINF. BARS AT BULB
WALL DIST. HORIZ. REINF.
WALL DIST. VERT. REINF.
HOOP REINF - WIDTH, B, DIR.
5
HOOP REINF - LENGTH DIR.
22
WALL EFFECTIVELY CONTINUOUS ?

hw
28
2
2
legs of
legs of

8060 k

BULB END DEPTH

1404 k

@
@
@
@

12
12
6
6

THE WALL DESIGN IS ADEQUATE.

= 237.5 ft
#
11
#
7
@ 12
in. o.c.
#
7
@ 12
in. o.c.
#
5
#
5
Yes (ACI 21.9.6.2 apply)

D
t
B

ANALYSIS
20000

15000

10000

Pn (k)
5000

0
0
-5000

20000 40000 60000 80000 10000 12000 14000 16000


0
0
0
0

-10000

Mn (ft-k)
CHECK MINIMUM REINFORCEMENT RATIOS AND SPACING (ACI 318-08 21.9.2.1 & 14.3)

(t )min. =
( )min. =
(t )provd. =
( )provd. =
where

0.0025

[ for

Acv (f c')0.5 =

0.0025

[ for

Acv (f c')

0.0063

>
>

(t )min.
( )min.

0.0063
Acv =

2
5535 in

0.5

350.09

kips

<

Vu , and bar size # 7 horizontal]

350.09

kips

<

Vu , and bar size # 7 vertical]

[Satisfactory]
[Satisfactory]

(gross area of concrete section bounded by web thickness and length in the shear direction)

The proposed spacing is less than the maximum permissible value of 18 in and is satisfactory. Since wall

Vu

>

2 Acv (f c')

0.5

two curtains reinforcement required. (ACI 318-08 21.9.2.2)


CHECK SHEAR CAPACITY (ACI 318-08 21.9.4.1 & 21.9.4.4)
Vn =MIN [ Acv (c (f c')0.5 + t f y), 8 Acv (f c')0.5 ] =
where

1665.56 kips

>

__

Vu

0.60 (conservatively, ACI 318-08 9.3.4 a)

c =

2.0

( for

>

[Satisfactory]

hw / L

8.24

>2)

(only for hw / L > 2.0, ACI 318-08 21.9.4.3)

Page 124 of 533


524

[Satisfactory]

in o.c.
in o.c.
in o.c.
in o.c.

CHECK FLEXURAL & AXIAL CAPACITY


MAXIMUM DESIGN AXIAL LOAD STRENGTH (ACI 318-08 21.9.5.1 & Eq.10-2)

Pmax =0.8 [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

Ag =
Ast =

15375 kips.

>

Pu

[Satisfactory]

0.65 (ACI 318-08 9.3.2.2)


2
6759 in .
2
116.36 in .

DESIGN MOMENT CAPACITY AT MAXIMUM AXIAL LOAD STRENGTH ARE FROM 0 TO 37085 ft-kips.
FOR THE BALANCED STRAIN CONDITION UNDER COMBINED FLEXURE AND AXIAL LOAD, THE MAXIMUM STRAIN IN THE CONCRETE
AND IN THE TENSION REINFORCEMENT MUST SIMULTANEOUSLY REACH THE VALUES SPECIFIED IN ACI 318-08 10.3.2
AS c = 0.003 AND t = f y / Es = 0.002069 . THE DEPTH TO THE NEUTRAL AXIS AND EQUIVALENT RECTANGULAR CONCRETE
STRESS BLOCK ARE GIVEN BY
Cb = d c / (c + s) =

195

= 0.65 + (t -0.002)(250/3) =

a = Cb 1 =

in

165

1 =

in

0.656 (ACI 318-08 Fig. R9.3.2)

0.85

d = (L - 0.5D ) =

( ACI 318-08 10.2.7.3 )


329

in

DESIGN AXIAL AND MOMENT CAPACITIES AT THE BALANCED STRAIN CONDITION ARE 7332 kips AND 103102 ft-kips.
IN ACCORDANCE WITH ACI 318-08 9.3.2 THE DESIGN MOMENT CAPACITY WITHOUT AXIAL LOAD IS
Mn = 0.9 n =

86262 kips.

TO KEEP TENSION SECTION WITH SHEAR CAPACITY PER ACI SEC. 11.9.6, THE PURE AXIAL TENSION CAPACITY IS
Pn = - 0.9 MIN(Ast Fy , 3.3 f c'0.5 4 L t ) = -4159 kips.
SUMMARY OF LOAD VERSUS MOMENT CAPACITIES ARE SHOWN IN THE TABLE BELOW, AND THEY ARE PLOTTED
ON THE INTERACTION DIAGRAM AT FRONT PAGE.

AT AXIAL LOAD ONLY


AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION

=
=
=
=
=

Pn (kips)
15375
15375
13650
11613
9949

Mn (ft-kips)
0
37085
54654
73516
85897

AT t = 0.002
AT BALANCED CONDITION

=
=

7428
7332

101295
103102

AT t = 0.005
AT FLEXURE ONLY
AT TENSION ONLY

=
=
=

6172
0
-4159

137743
86262
0

DESIGN FORCES Pu & Mu ARE ALSO PLOTTED ON THE INTERACTION DIAGRAM. FROM THE INTERACTION DIAGRAM.
THE ALLOWABLE MOMENT AT AN AXIAL LOAD Pu IS GIVEN BY
Mn =

97675

>

kips.

Mu

[Satisfactory]

where = Min{0.9, Max[0.65 + (t - 0.002)(250/3) , 0.65]} = 0.650

(ACI 318-08 Fig. R9.3.2)

CHECK BOUNDARY ZONE REQUIREMENTS


AN EXEMPTION FROM THE PROVISION OF BOUNDARY ZONE CONFINEMENT REINFORCEMENT IS GIVEN BY ACI318-05 21.9.6.2,
21.9.6.3, and 21.9.6.5(a) PROVIDED THAT
c < (L hw) / (600 u) for ACI 21.9.6.2 apply
where

c =

208

f c < 0.2 f c' for ACI 21.9.6.3 apply

or

[Unsatisfactory]

in. ( distance from the extreme compression fiber to neutral axis at Pu & Mn loads. )

u = 20.0 in. ( design displacement, assume 0.007hw as a conservative short cut, see ACI 318-08 21.9.6.2a. )
f c = (Pu / A) + (Mu y / I )
y =
A =
I =

173

2.978

ksi. ( the maximum extreme fiber compressive stress at Pu & Mu loads. )

in. ( distance from the extreme compression fiber to neutral axis at Pu & Mu loads. )

7696
94443188

in . ( area of transformed section. )


4
in . ( moment of inertia of transformed section. )

Or the longitudinal reinforcement ratio at the wall end =

0.038

>

400 / f y

__

[Unsatisfactory]

HENCE SPECIAL BOUNDARY ZONE DETAILING REQUIRED !


The boundary element length = MAX( c - 0.1L , 0.5 c , D + 12 ) =173.71 in. ( ACI 318-08 21.9.6.4 )
The maximum hoop spacing = MIN[ B/3 , 6db , 6 , 4+(14-hx)/3 ] =
The required hoop reinforcement
( ACI 318-08, Eq.21-4 )

in.o.c. ( ACI 318-08 21.6.4.2 & 21.9.6.5a )

Ash, B DIR = (0.09 s hc f c' ) / f yh =

2
0.273 in .

<

# 5 provided

[Satisfactory]

Ash, L DIR = (0.09 s hc f c' ) / f yh =

2
0.294 in .

<

# 5 provided

[Satisfactory]

Page 125 of 533


524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Ordinary Reinforced Concrete Shear Wall Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH (ACI 318 5.1.1)

f c'

ksi

FACTORED AXIAL LOAD

Pu

5000

REBAR YIELD STRESS

fy

60

ksi

FACTORED MOMENT LOAD

Mu

28026 ft-k

FACTORED SHEAR LOAD

Vu

1100

LENGTH OF SHEAR WALL


THICKNESS OF WALL

L
t

=
=

28
12

ft
in

WALL DIST. HORIZ. REINF.


WALL DIST. VERT. REINF.

2
2

#
#

7
7

@
@

VERT. REINF. BARS AT END

THE WALL DESIGN IS ADEQUATE.


18
18

in. o.c.
in. o.c.

ANALYSIS
10000

8000

6000

Pn (k)
4000

2000

0
0

10000

20000

30000

40000

50000

-2000

Mn (ft-k)
CHECK MINIMUM REINFORCEMENT RATIOS AND SPACING (ACI 318-08 14.3)

(t )provd. =
( )provd. =

0.0056
0.0056

(t )min. =
( )min. =

>
>

0.0025

[Satisfactory]

0.0015

[Satisfactory]

CHECK SHEAR CAPACITY (ACI 318-08 11.2 & 21.9.4)


Vn =MIN [ Acv (2 (f c')0.5 + t f y), 8 Acv (f c')0.5 ] =
where

Acv =

1112.4 kips

>

Vu

0.60 (conservatively, ACI 318-08 9.3.4 a)


2
4032 in

CHECK FLEXURAL & AXIAL CAPACITY


THE ALLOWABLE MOMENT AT AN AXIAL LOAD Pu IS GIVEN BY
Mn =

35406

kips.

>

Mu

[Satisfactory]

where = Min{0.9, Max[0.65 + (t - 0.002)(250/3) , 0.65]} = 0.650

(ACI 318-08 Fig. R9.3.2)

__
Page 126 of 533
524

[Satisfactory]

"

$% & $

! '()*+,-.+(+!&! !#

"#$

'

()

"#$

)() "

3 %% &5"

"
%

&

,
-

4 4

4/

%
-

(
!
!

&
$
+
$
+
$
+

% 3

&

3
3

8
8

&

,
7
-5
-5

;<
%
%
%
=1># 9
=1># 9

: :
%%
, , ?

--

6
6
6
6
6

<;1D1

>

"

-5
-5

3 3

$
+

6
%
%

6
6
6
6

: :

%%

$
+ 9
$
+ 9

3
3

8
8
8
8

%
%
(
(

"

% 3(% @AA='

) B)

)()

%
%

12

&
1#

4
/

!)! "

&
()) $
+
!)) $
+

B!(

>

"

C @&$
# @ &9D'E

%
(3 B $
+

%))))

)))

))))
+

"
)))

)
)

%)))) !)))) ())))

))))

))))) %)))) !)))) ())))

5 )))

5 ))))

4+ &5"
*4

4,4

5) % 3%

& G$+

) ))%

C 9D

= G$
+

) ))%

C 9D

& AD9HJ

) ))(

= AD9HJ

) ))(

<;1D1

) )B

"$
A#

/ : @+J 2@D#$
K163;9D$
K9+&@=E

) )B

"$
A#

/ : @+J 2@D#$
K163H1D&$@=E

H
H

C @&$
# @ &9D'E

& G$+

$
+

= G$
+
%

F !

C @&$
# @ &9D'E
>D9##@D1@9 9+ D1&1#1 &$
9+ 29/+J1J 2' <12&;$"+1## @+J =1+>&; $
+ &;1 #;1@DJ$
D1 &$
9+

;1AD9A9#1J#A@ $
+> $
# =1## &;@+ &;1G @L$
G /G A1DG $
##$
2=1H@=/19

$
+ @+J $
# #@&$
#@ &9D'

$
+ 1 <@==

&<9 /D&@$
+#D1$
+ 9D 1G 1+& D1M/$
D1J
*

5) % 3! F % 3!!
+

<;1D1

& '

) ()

%)
=

&

9+#1DH@&$
H1=':

9D ;< N
C @&$
# @ &9D'E

((

( "$
A#

5) B !@

%!

O%

9+=' 9D;< N O % ):

5) % 3 !

C @&$
# @ &9D'E

5) % 3% %

$
+9
$
+9
$
+9
$
+9

!"#$% &'&$&
)*+ ,#&!

-#&!$.

9:;8;

/"

03 ,

#&<$

(& #"%

$ '$ 45
60&

- *5
0.*

823

!"#$ =& &%&%


%

<& < 5 &

1 .2

#
>

'#!$ . "45
60&

>

?
@

, #&##

, .2 A

>

>

, #&<$1

, #&##%#<=&

!"#$ #& &%


B

*,

=$ 5

"#&##% %$#A ,

#&<$<

<$ 5

!"#$ 5
/&

=& &%

>
D
,

!"#$ #&%&'&

%= 5

' % 45
60

!"#$ =& &%

, #&=

#&!$
"#&$

# #% . "45
60&

!<%<% 45
60&
D

, "#&=

&

?& .

#&$

& #&<?

"E $= 45
60&

>

>

D?

&
,
,
,
,
,

$ '$
$ '$
<$#
<
==E=

#
'#!$
$E<$E
'$<
!$!='

, #&##%

,
,

'E%!
' %

# %=$
# #%

, #&##$

,
,
,

< '%
#
"E $=

''E
!<%<%
#

#F
%$F
$#F
>

&

D >
='<'$

9:;8; ,

45
60&

% &'&<& ?*

% &'&<&$ *

!"#$ 5
/&

=& &%

>

% &'&<&% *66K
2

>

!"#$ % &'&<&%?

@
. 8

9:;8;
7

. J #&% .

%#! 5 &

5
0 * ; .8 ) :;;+ 8;) ;

%#&# 5 &

;05
/

. ,

7A

2 ,

'

5&

,
,

72A

=EEE

%&='!

>
I
*82 ;K
;); K
; /: ,

:;) *+5
) 7) : 606* 5 / ,
:;8;(75
8; : 68;5 . 8 ;) ;
!"#$? (&% "E

405
&

5
0 * ; .8 ) :;;+ 8;) ;

'<=<
!!

. 8

5 E&

) );

0:?

!"#$ % &'&<&%*&

;7 8*K*+5
0*

K* 0&

K* 0&

. 5 ;85
* . 8* 0. 8) ; 0; 5 &
,

:+ A 3 ,
C ?<?E1 E"
, #&#=0 : .
, #&#=0 : .

E## A.2

#&# !

B
M
?#&$ ? 1 % , ' &'

0:?>

823

K* 0&

0;8L* 5
L;0: 8 7 ?0;;

) 68;005 .5
C;8

*8;* . 8* 0. 8); 0; 5 &

"#&

- 0*5
0.*

;7 8*K*+5
0*

:; ) *+5
)7) ;+ 8;) ;.5
C;8 ) 68;005
L;0 8;00 *

5 %&

->AE ?<

% &'&<& *66K
2

) 68;005 .5
C;8

5
06K
* ;) ; ?*007) ;#&##':9 *0 *

8 :; K /57 5 *K8;5 . 8 ;) ; 8* 5 * :;9*K


K;
:;C 7

823

"#&##% %$#A ?#&<$3H, #&<$#

@
:9 A <##

>

- *5
0.*

5 G#&=? *+-#&<$1

>

&

5&

- 0*5
0.*

823

!"#$ % &'&<&E
<

5& & &


%

!"#$% &E&E&%

% &'&<&$*

A.2: ,

#&%'

5 &

N$68 L5;

- *5
0.*

823

A.2: ,

%
#&%=E 5 &

N$68 L5;

- *5
0.*

823

PROJECT :
PAGE :
CLIENT :
DESIGN BY :
JOB NO. :
DATE :
REVIEW BY :
Verify Existing Reinforced Concrete Shear Wall Capacity Based on ASCE 41-06 / CBC 10 / IBC 09
INPUT DATA

OUTPUT SUMMARY

CONCRETE STRENGTH (ACI 318 5.1.1)

fc'

ksi

SHEAR WALL LENGTH

28.83 ft

REBAR YIELD STRESS

fy

60

ksi

SHEAR WALL THICKNESS


BULB END WIDTH

t
B

=
=

16.00 in
34.00 in

FACTORED AXIAL LOAD

Pu

D + Web

169.80 in

FACTORED MOMENT LOAD

Mu

= 87822 ft-k

BULB REINFORCING

28

11

FACTORED SHEAR LOAD

Vu

1404 k

LENGTH OF SHEAR WALL


THICKNESS OF WALL
DEPTH AT FLANGE
WIDTH AT FLANGE

L
t
D
B

=
=
=
=

28.83
16
34
34

ft
in
in
in

WALL HORIZ. REINF


WALL VERT. REINF
HOOP REINF - WIDTH, B, DIR.
HOOP REINF - LENGTH DIR.

2
2
5
22

#
#
#
#

7
7
5
5

hw
28
2
2
legs of
legs of

=
#
#
#
#
#

237.5
11
7
7
5
5
Yes

ft

TOTAL WALL HEIGHT TO TOP


REINF. BARS AT BULB
WALL DIST. HORIZ. REINF.
WALL DIST. VERT. REINF.
HOOP REINF - WIDTH, B, DIR.
5
HOOP REINF - LENGTH DIR.
22
WALL EFFECTIVELY CONTINUOUS ?

MAX CONCRETE COMPRESSION STRAINS


MAX REINFORCEMENT TENSILE STRAINS

8060 k

@
@

BULB END DEPTH

@
@
@
@

12
12
6
6

THE WALL DESIGN IS ADEQUATE.

L
12
12

in. o.c.
in. o.c.

t
B

(ACI 21.9.6.2 apply)

0.002 (ASCE 6.3.3.1)


0.05 (ASCE 41-06 Sec. 6.3.3.1)

ANALYSIS
DETERMINE WHETHER THE WALL CAN RESIST SEISMIC LOADS (CBC 2010 1908A.1.38)
Pu =

8060

where

Ag =

<

0.35 Ag fc' =

9463 k

[Satisfactory]

6759 in2.

20000

15000

10000

Pn (k)
5000

0
0

20000

40000

60000

80000

100000 120000 140000

-5000

-10000

Mn (ft-k)
CHECK MINIMUM REINFORCEMENT RATIOS AND SPACING (ACI 318-08 21.9.2.1 & 14.3)

(t )min. =

0.0025

[ for

Acv (fc')0.5 =
0.5

(l )min. =

0.0025

[ for

Acv (fc')

(t )provd. =
(l )provd. =

0.0063

>
>

(t )min.
(l )min.

where

0.0063
Acv =

2
5535 in

350.09

kips

<

Vu , and bar size # 7 horizontal]

350.09

kips

<

Vu , and bar size # 7 vertical]

[Satisfactory]
[Satisfactory]

(gross area of concrete section bounded by web thickness and length in the shear direction)

The proposed spacing is less than the maximum permissible value of 18 in and is satisfactory. Since wall

Vu

>

2 Acv (fc')0.5 ,

two curtains reinforcement required. (ACI 318-08 21.9.2.2)


CHECK SHEAR CAPACITY (ACI 318-08 21.9.4.1 & 21.9.4.4)
Vn =MIN [ Acv (c (fc')0.5 + t fy), 8 Acv (fc')0.5 ] =
1665.56 kips
where

=
0.60 (conservatively, ACI 318-08 9.3.4 a)

c =

2.0

( for

>

[Satisfactory]

hw / L

8.24

>

>2)

(only for hw / L > 2.0, ACI 318-08 21.9.4.3)

Vu

[Satisfactory]

in o.c.
in o.c.
in o.c.
in o.c.

(cont'd)
CHECK FLEXURAL & AXIAL CAPACITY
MAXIMUM DESIGN AXIAL LOAD STRENGTH (ACI 318-08 21.9.5.1 & Eq.10-2)

Pmax =0.8 [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

Ast =

15375 kips.

>

Pu

[Satisfactory]

0.65 (ACI 318-08 9.3.2.2)


2
116.4 in .

DESIGN MOMENT CAPACITY AT MAXIMUM AXIAL LOAD STRENGTH ARE FROM 0 TO 32514 ft-kips.
FOR THE BALANCED STRAIN CONDITION UNDER COMBINED FLEXURE AND AXIAL LOAD, THE MAXIMUM STRAIN IN THE CONCRETE
AND IN THE TENSION REINFORCEMENT MUST SIMULTANEOUSLY REACH THE VALUES SPECIFIED IN ACI 318-08 10.3.2
AS c AND t INPUT . THE DEPTH TO THE NEUTRAL AXIS AND EQUIVALENT RECTANGULAR CONCRETE
STRESS BLOCK ARE GIVEN BY
Cb = d c / (c + s) =

162

= 0.65 + (t -0.002)(250/3) =

a = Cb 1 =

in

137

1 =

in

0.656 (ACI 318-08 Fig. R9.3.2)

0.85

d = (L - 0.5D ) =

( ACI 318-08 10.2.7.3 )


329

in

DESIGN AXIAL AND MOMENT CAPACITIES AT THE BALANCED STRAIN CONDITION ARE 5807 kips AND 98948 ft-kips.
IN ACCORDANCE WITH ACI 318-08 9.3.2 THE DESIGN MOMENT CAPACITY WITHOUT AXIAL LOAD IS
Mn = 0.9 n =

85864 kips.

TO KEEP TENSION SECTION WITH SHEAR CAPACITY PER ACI SEC. 11.10.6, THE PURE AXIAL TENSION CAPACITY IS
Pn = - 0.9 MIN(Ast Fy , Ast Es s, 3.3 fc'0.5 4 L t ) =

-4159 kips.

SUMMARY OF LOAD VERSUS MOMENT CAPACITIES ARE SHOWN IN THE TABLE BELOW, AND THEY ARE PLOTTED
ON THE INTERACTION DIAGRAM AT FRONT PAGE.
AT AXIAL LOAD ONLY
AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION

=
=
=
=
=

Pn (kips)
15375
15375
13247
10605
8649

Mn (ft-kips)
0
32514
52220
74301
85560

AT t = 0.002
AT BALANCED CONDITION

=
=

5924
5807

97415
98948

AT t = 0.005
AT FLEXURE ONLY
AT TENSION ONLY

=
=
=

4121
0
-4159

123235
85864
0

DESIGN FORCES Pu & Mu ARE ALSO PLOTTED ON THE INTERACTION DIAGRAM. FROM THE INTERACTION DIAGRAM.
THE ALLOWABLE MOMENT AT AN AXIAL LOAD Pu IS GIVEN BY
Mn =

88382

>

kips.

Mu

[Satisfactory]

where = Min{0.9, Max[0.65 + (t - 0.002)(250/3) , 0.65]} =

0.650

(ACI 318-08 Fig. R9.3.2)

CHECK BOUNDARY ZONE REQUIREMENTS


AN EXEMPTION FROM THE PROVISION OF BOUNDARY ZONE CONFINEMENT REINFORCEMENT IS GIVEN BY ACI318-05 21.9.6.2,
21.9.6.3, and 21.9.6.5(a) PROVIDED THAT
c < (L hw ) / (600 u) for ACI 21.9.6.2 apply
where

c =

204

fc < 0.2 fc' for ACI 21.96.3 apply

or

[Unsatisfactory]

in. ( distance from the extreme compression fiber to neutral axis at Pu & Mn loads. )

u = 20.0 in. ( design displacement, assume 0.007hw as a conservative short cut, see ACI 318-08 21.9.6.2a. )
fc = (Pu / A) + (Mu y / I )
y =

173

2.978

ksi. ( the maximum extreme fiber compressive stress at Pu & Mu loads. )

in. ( distance from the extreme compression fiber to neutral axis at Pu & Mu loads. )

A =

7696

I =

94443188

in2. ( area of transformed section. )


in4. ( moment of inertia of transformed section. )

Or the longitudinal reinforcement ratio at the wall end =

0.038

>

400 / fy

[Unsatisfactory]

HENCE SPECIAL BOUNDARY ZONE DETAILING REQUIRED !


The boundary element length = MAX( c - 0.1L , 0.5 c , D + 12 ) = 169.80 in. ( ACI 318-08 21.9.6.4 )
The maximum hoop spacing = MIN[ B/3 , 6db , 6 , 4+(14-hx)/3 ] =
The required hoop reinforcement
( ACI 318-08, Eq.21-4 )

in.o.c. ( ACI 318-08 21.6.4.2 & 21.9.6.5a )

Ash, B DIR = (0.09 s hc fc' ) / fyh =

2
0.273 in .

<

# 5 provided

[Satisfactory]

Ash, L DIR = (0.09 s hc fc' ) / fyh =

2
0.287 in .

<

# 5 provided

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Tilt-up Panel Design based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

bt

f 'c =

ksi

fy =

60

ksi

LATERAL SERVICE LOAD

REBAR STRENGTH

w1 =

27

psf, for wall

(ASD level, 0.7 E)

w2 =

86

psf, for parapet

seismic

LATERAL LOAD TYPE (0 or 1)


LEDGER DL

P1DL =

0.8

LEDGER LL

P1LL =

0.8

k/ft

in

e1 =

DIST. FROM FACE

diaphragm

P1

P2

e1

k/ft

PARAPET DL

P2DL =

0.18

k/ft

PARAPET LIVE LOAD

P2LL =

k/ft

ELEMENT WIDTH

be =

ft

design panel

wall load

be

TRIBUTARY WIDTH

bt =

ft

WALL THICKNESS

t =

in

WALL VERT. SPAN

h =

22

ft

PARAPET HEIGHT

hp =

ft

VERT. REINF.- MIDDLE

LAYER

12 in, o.c.

HORIZ. REINF. - MIDDLE

LAYER

12 in, o.c.

REVEAL THICKNESS

0.75

in

ANALYSIS
CHECK VERTICAL FACTORED LOAD LESS THAN 0.06fc'Ag (ACI 318-08 Sec. 14.8.2.6)

P u = (1.2 P1DL + 1.6 P1LL + 1.2 P 2 DL + 1.6 P 2 LL + 1.2wwt 0.5h ) bt

3.78

<

0.06fc'Ag =

20.88 k

[SATISFACTORY]

CHECK VERTICAL REINFORCEMENT LESS THAN 0.6b (ACI 318-08 Sec. 14.8.2.3 & R9.3.2.2)

MAX =

0.85 1 f c'

u +t

fy

0.85 1 f c'
fy

u
u + 0.005

actual =

>

0.018

0.014

[SATISFACTORY]

CHECK Mcr LESS THAN Mn (ACI 318-08 Sec. 14.8.2.4)

= MAX 0.9

M cr =

7.5

0.25 P u
'
MIN 0.1 f c A g , P b

, 0.65

= 0.8736

(ACI 318-08 Sec. 9.3.2.2)

M n = Ase f y d

'

f cIg
=
yt

49.87

<

k-in

where

(ACI 318-08 Sec. 9.5.2.3)

a
2

d=

117.19

3.63

Ase = As + Pu t / (2 fy d) =

[SATISFACTORY]

k-in

in
0.72

in2

(ACI 318 R14.8.3)


CHECK WALL STRENGTH

b ec
I cr = n Ase( d c ) +
3
2

41

Mua =

in4

2
wb
1 th

+ P1u

e + 0.5t
2

43.4

k-in, ( =

1 / 0.7 for seismic)

(ACI 318-08 Sec. 14.8.3)

Mu =

M ua
5P u h 2
0.75
(
) 48E c I cr

55.5 k-in

M n

<

(ACI 318-08 Sec. 14.8.3, Eq14-6)

117.19

k-in

[SATISFACTORY]

CHECK SERVICE LOAD OUT-OF-PLANE DEFLECTION (ACI 318-08 Sec. 14.8.4

M sa =

e + 0.5t
w1b t h +
( P1DL + 0.5P1LL )
8
2
2

5M cr h 2
=
cr =
48 E c I g

s =

0.26

n =

in

25.6 k-in
2

5M n h
=
48E c I cr

6.65

__

2
M sa 2 / 3M cr
( n 2 / 3 cr ) , for M sa 2 / 3M cr
cr +
3
M n 2 / 3M cr
M sa
cr , for M sa < 2 / 3M cr
M cr

CHECK PARAPET STRENGTH

Mu, parapet =

w2bth2p
2

in

k-in

<

0.14

M n = 0.9 As e f y d

Page 131 of 533


524

<

in

a
2

h
150

1.76 in

[SATISFACTORY]

117 k-in

[SATISFACTORY]

PROJECT :
CLIENT :
JOB NO. :
Wall Pier Design Based on CBC 2007 / IBC 2009

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH
fc' =
REBAR YIELD STRESS
fy =
WALL PIER LENGTH
L =
WALL PIER HEIGHT
H =
WALL PIER THICKNESS
t =

ksi

60

ksi

ft

12

ft

10

in

VERTICAL EDGE BARS, As


2
#
9
TRANSVERSE REINFORCEMENT, Av
2
#
5

FACTORED AXIAL LOAD

Pu =

60

kips

FACTORED SHEAR FORCE

Vu =

35

kips, (in plane)

THE DESIGN IS ADEQUATE.


6

in, o.c. (at each face.)

ANALYSIS
CHECK WALL PIER DEFINITION (CBC 2007 1908.1.3 / IBC 2009 1908.1.4)
L/t=
6.00
within [2.5 , 6]
&
H/L=

2.40

>

2
[Satisfactory]

CHECK SHEAR STRENGTH (CBC 2007 1908.1.8 / IBC 2009 1908.1.4 / ACI 318-08 21.6.5.1)
Ve = (Mpr, left, top + Mpr, right,bot) / H + Vu =
149.8
kips

<
<

where

d=

left =
right =

58.06

8(fc')0.5bd =

152.6

kips

[Satisfactory]

[Vc + Avfyd/s ] =
216.0
in, (ACI 318 3.3.2, 7.6.1, & 7.7.1)

kips

[Satisfactory]

min=MIN[3(fc')0.5/fy, 200/fy ]=
0.003
min =
0.003
[Satisfactory]
689
ft-kips
Mpr, left, top = left bd2fy (1.25 - 0.919left fy/fc') =
Mpr, right ,bot = right bd2fy (1.25 - 0.919right fy/fc') =
689
ft-kips

=
Av =

>
>

0.003

0.003

0.6
0.62

Vc = 2(fc')0.5bd =

[Satisfactory]

(ACI 318 9.3.4)


in2
0.0

kips, (Per ACI 318-08 21.6.5.2, Vc = 0, if (Ve -Vu)

__
Page 132 of 533
524

50% Ve AND Pu < Ag fc' / 20 )

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Concrete Slab Capacity Based on ACI 318-08


4.5
60

f'c =
fy =

ksi
ksi

t
cC

#
#
#
#
#
#
#
#
#
#
#
#

REBAR
6 @ 24
6 @ 22
6 @ 20
6 @ 18
6 @ 16
6 @ 14
6 @ 12
6 @ 10
6 @ 8
6 @ 6
6 @ 4
6 @ 2

#
#
#
#
#
#
#
#
#
#
#
#

5
5
5
5
5
5
5
5
5
5
5
5

@
@
@
@
@
@
@
@
@
@
@
@

24
22
20
18
16
14
12
10
8
6
4
2

5
60

f'c =
fy =

=
=

7.25
1

" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.

As, in /ft
0.220
0.240
0.264
0.293
0.330
0.377
0.440
0.528
0.660
0.880
1.320
2.640

d, in
5.88
5.88
5.88
5.88
5.88
5.88
5.88
5.88
5.88
5.88
5.88
5.88

a, in
0.288
0.314
0.345
0.383
0.431
0.493
0.575
0.690
0.863
1.150
1.725
3.451

T, k/ft
13.20
14.40
15.84
17.60
19.80
22.63
26.40
31.68
39.60
52.80
79.20
158.40

Mn, ft-k/ft
5.67
6.18
6.77
7.50
8.40
9.55
11.06
13.14
16.17
20.99
29.77
49.30

" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.

0.155
0.169
0.186
0.207
0.233
0.266
0.310
0.372
0.465
0.620
0.930
1.860

5.94
5.94
5.94
5.94
5.94
5.94
5.94
5.94
5.94
5.94
5.94
5.94

0.203
0.221
0.243
0.270
0.304
0.347
0.405
0.486
0.608
0.810
1.216
2.431

9.30
10.15
11.16
12.40
13.95
15.94
18.60
22.32
27.90
37.20
55.80
111.60

4.07
4.43
4.87
5.40
6.05
6.89
8.00
9.53
11.79
15.44
22.30
39.52

ksi
ksi

t
cC

=
=

7.25
1.5

in
in

REBAR
5 @ 24
5 @ 22
5 @ 20
5 @ 18
5 @ 16
5 @ 14
5 @ 12
5 @ 10
5 @ 8
5 @ 6
5 @ 4
5 @ 2

" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.

As, in /ft
0.155
0.169
0.186
0.207
0.233
0.266
0.310
0.372
0.465
0.620
0.930
1.860

d, in
5.44
5.44
5.44
5.44
5.44
5.44
5.44
5.44
5.44
5.44
5.44
5.44

a, in
0.182
0.199
0.219
0.243
0.274
0.313
0.365
0.438
0.547
0.729
1.094
2.188

T, k/ft
9.30
10.15
11.16
12.40
13.95
15.94
18.60
22.32
27.90
37.20
55.80
111.60

Mn, ft-k/ft
3.73
4.06
4.46
4.94
5.55
6.31
7.33
8.74
10.81
14.15
20.47
36.35

#
#
#
#
#
#
#
#
#
#
#
#

4
4
4
4
4
4
4
4
4
4
4
4

" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.
" O.C.

0.100
0.109
0.120
0.133
0.150
0.171
0.200
0.240
0.300
0.400
0.600
1.200

5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50
5.50

0.118
0.128
0.141
0.157
0.176
0.202
0.235
0.282
0.353
0.471
0.706
1.412

6.00
6.55
7.20
8.00
9.00
10.29
12.00
14.40
18.00
24.00
36.00
72.00

2.45
2.67
2.93
3.25
3.65
4.17
4.84
5.79
7.19
9.48
13.90
25.89

24
22
20
18
16
14
12
10
8
6
4
2

7.17
7.17
7.17
7.17
7.17
7.17
7.17
7.17
7.17
7.17
7.17
7.17

in
in

#
#
#
#
#
#
#
#
#
#
#
#

@
@
@
@
@
@
@
@
@
@
@
@

Vn, k/ft
7.09
7.09
7.09
7.09
7.09
7.09
7.09
7.09
7.09
7.09
7.09
7.09

__
Page 133 of 533
524

Vn, k/ft
6.92
6.92
6.92
6.92
6.92
6.92
6.92
6.92
6.92
6.92
6.92
6.92
7.00
7.00
7.00
7.00
7.00
7.00
7.00
7.00
7.00
7.00
7.00
7.00

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Voided Section Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH
f c' =
REBAR YIELD STRESS
fy =

ksi

60

ksi

TOTAL SLAB THICKNESS


t =
18
in
TOP & BOTTOM SOLID THICKNESS
tsolid =
4
in
VOIDED HORIZONTAL DIAMETER
D =

20

VERTICAL WEB THICKNESS


w =
2.5

in, (input 10 for Sphere/Circle)

M n =

32.7

ft-kips / ft

Vn =

11.0

kips / ft

in

THE DESIGN IS ADEQUATE.


SECTION BARS

@
with

12
0.75

o.c.
in. bottom concrete cover

ANALYSIS
CHECK SECTION LIMITATIONS
tsolid =

in

>

0.75
(inside cover)

D =

20

in

>

10

in, voided height

[Satisfactory]

w =

2.5

in

>

2.5

in

[Satisfactory]

1.50
(2 rebar thick)

0.75
=
(top & bot cover)

3.00

in, solid min thk


[Satisfactory]

DETERMINE FLEXURE CAPACITY (ACI 318-08 7.12.2.1, 10.2, 10.5.1)


wc =

150

Ec = wc1.5 33 f'c0.5 =

pcf, (ACI 318-08 8.5.1)

o =

d =
As =
Mn =

16.88
0.44

in
in2 / ft

c =

32.7

ft-kips / ft, (by pure math method)

>

3834

'

2 0.85 f C
Ec

0.85 f
=

0.85 f

'
C

, E s = 29000ksi

2
2 c c ,
o o

, for c o
,
for s t

s E s
=
,
for
f
s >t

in
in2 / ft

0.9

,(ACI 318-08 Fig R9.3.2)

0.75

,(ACI 318-08 9.3.2.3)

Ac =

116

in2 / ft

DETERMINE ONE WAY SHEAR CAPACITY (ACI 318-08 11.1.3.1, & 11.2)
Vn = 2Ac (fc')0.5 =

11.0

kips / ft

for 0 < c < o

'
C

0.39

Amin =

0.84

ksi, (ACI 318-08 8.5.1)

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Concrete Diaphragm in-plane Shear Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH (ACI 318, 5.1.1) fc'
LIGHTWEIGHT CONCRETE ? (ACI 318, 8.6)

4
Yes

ksi
(Lightweight Concrete)

REBAR YIELD STRESS

fy

60

ksi

THICKNESS OF DIAPHRAGM

3.5

in

DIAPHRAGM REINFORCING

Vu

10

kips/ft

THE DIAPHRAGM DESIGN IS ADEQUATE.

FACTORED IN-PLANE SHEAR LOAD

12

in. o.c.

(at Middle, Each Way)

ANALYSIS
CHECK MINIMUM REINFORCEMENT RATIOS (ACI 318, 21.11.7 & 7.12)

(t )provd. =

0.0048

>

(t )min. =

0.0018

[Satisfactory]

CHECK SHEAR CAPACITY (ACI 318, 21.11.9)


Vn =MIN [ Acv (2 (fc')0.5 + t fy), 8 Acv (fc')0.5 ] =
where

Acv =

0.75 (ACI 318, 9.3.2.3)


2
42 in

0.75 (ACI 318, 8.6.1)

12.0

kips/ft

__
Page 134 of 533
524

>

Vu

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Base Plate and Group Anchors Design Based on ACI 318-08 & AISC 360-05
INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc' =

ksi

SPECIFIED STRENGTH OF ANCHOR

futa =

58

ksi

BASE PLATE YIELD STRESS

fy =

36

ksi

CRITICAL BASE PLATE CANTILEVER

m=

3.3

in

FACTORED AXIAL LOAD AT WORK POINT

Pu =

150

kips

FACTORED SHEAR LOAD AT WORK POINT

Vu =

16

kips, ( 0 if shear lug used.)

FACTORED MOMENT AT WORK POINT

Mu =

260

ft-kips

EFFECTIVE EMBEDMENT DEPTH

hef =

22

in

ANCHOR DIAMETER

d=

ANCHOR HEAD TYPE

ANCHOR LOCATION TO WORK POINT


X (in)
Y (in)
Anchor

in

-8

Heavy Hex

-8

-8

-8

24

6
7
8

24
-8
24

-8
0
0

( 1=Square, 2=Heavy Square, 3=Hex, 4=Heavy Hex, 5=Hardened Washers )


BASE PLATE THICKNESS

t=

SEISMIC LOAD ? (ACI 318 D3.3)

== >

1.75

in

Yes

Work Point

BASE PLATE SIZE - 36 in x 20 in x 1.75 in (thk.)


X (in)
Y (in)
Corner
1
-9.75
-9.75
Edge =
1.75 in
2
-9.75
9.75
(AISC 360-05, Tab J3.4 & J3.5)
3
25.75
9.75
4
25.75
-9.75
-9.75
-9.75

THE BASE PLATE & GROUP ANCHORS DESIGN IS ADEQUATE.


ANALYSIS
CHECK FLEXURAL & AXIAL COMPRESSION CAPACITY OF ANCHORED CONCRETE (ACI 318-08 Sec 9 & Sec 10)
3000

2500

H
I Pn (k)

2000
1500
1000
500
0
0

500
I Mn (ft-k)

1000

1500

(cont'd)
I Mn =

451
0u, c =

>

ft-kips @ Pu =
363

150

kips

ft-kips to center of base plate

Ho

[Satisfactory]
I Pmax =

2643

>

Pu =

kips
150

ft-kips

[Satisfactory]

fC
Nua,1 =

3.13

kips

(The 1/0.4 times max tension, ACI 318 D3.3.6)


fp =

4.42

fS

ksi, the max possible concrete compression stress.


(ACI 318-08, 10.17.1 & 9.3.2.4, or AISC Guide - 1)

2 f C'
Ec

0.85 Min A2 , 2 , E c 57 f C' , E s 29000ksi


A1


0.85Min A2 , 2 f C' 2 H c  H c , for 0  H c  H o

A1
o H o

A2

, 2 f C' , for H c t H o
0.85Min
A1

H s E s , for H s d H y

f y , for H s ! H y

DETERMINE EACH ANCHOR FORCES WITHOUT CONCTERE COMPRESSION CAPCAITY CONSIDERED


Anchor

X (in)

Y (in)

XCG

YCG

Nua, 2

Vua

1
2
3
4

-8
-8
8
8

8
-8
8
-8

256
256
0
0

64
64
64
64

1.25
1.25
-18.75
-18.75

2.00
2.00
2.00
2.00

XCG =
YCG =

24

256

64

-38.75

2.00

Pu,CG =

150.0

kips

24

-8

256

64

-38.75

2.00

Vu,CG =

16.0

kips

160.0

ft-kips

0.0

ft-kips

-8

256

1.25

2.00

Mu,CG, X =

24

256

-38.75

2.00

Mu,CG, Y =

1536

384

-150

16

8
0

in
in

CHECK GOVERNING ANCHOR TENSILE STRENGTH (ACI 318, D.5.1.2)

INs

I A se f

where :

uta

0.75

Ase

0.606

19.77
x

>

kips
0.75

Nua = Max( Nua,1 , Nua,2 ) =

0.5625 , (ACI 318-08 D.4.4 & D.3.3.3)

in2

CHECK CONCRETE BREAKOUT STRENGTH OF GOVERNING ANCHOR (ACI 318, D.5.2.1)

I N cb I A N \ ec , N\ ed , N\ c, N N b I A N2 \ ec, N1.0\ c , N 24 f 'c h1.5


ef
9h ef
A No
=

22.026 k

where :

\ ec,N
\ c,N
AN

=
=

=
=

0.75

>

Nua =

3.13

0.75

kips

[Satisfactory]

0.5625

1.0, for no eccentricity in the connection.


1.0, for location where concrete cracking is likely to occur.
1089

in2, (conservative value)

CHECK CONCRETE BREAKOUT STRENGTH OF ALL ANCHORS (ACI 318, D.5.2.1)

I N cbg I A N \ ec , N\ ed , N\ c , N N b I A N2 \ ec , N1.0\ c, N 24 f 'c h1.5


ef
9hef
A No
=

136.134 k

>

- Pu =

3.13

-150

kips


[Satisfactory]

kips

[Satisfactory]

where :

=
=
=

\ ec,N
AN

0.75

0.84

0.75

0.5625

(cont'd)

, (ACI 318-08 Fig. RD.5.2.4)

98

82

in

8036

CHECK PULLOUT STRENGTH OF GOVERNING ANCHOR (ACI 318, D.5.3.1)

I N pn I\ cp , N Ab8 f 'c
where :

0.75

Ab

1.501

\ cp,N

>

27.018 k

Nua =

3.13

kips

[Satisfactory]

x
0.75
=
0.5625
2
in , ( or determined from manufacture's catalogs.)

1.0, for location where concrete cracking is likely to occur.

CHECK SIDE-FACE BLOWOUT STRENGTH (ACI 318, D.5.4.1)

>

cmin

0.4 hef

[Satisfactory]

Since this fastener is located far from a free edge of concrete (c > 0.4 hef ) this type of failure mode is not applicable.
DETERMINE DESIGN TENSILE STRENGTH OF GOVERNING ANCHOR

INn

min I N s , I N cb , I N pn

19.771

CHECK GOVERNING ANCHOR SHEAR STRENGTH (ACI 318, D.6.1.2b & D.3.3.6)

IV s

I 0.6 Ase f ut
I

where :

10.28

0.65

k
0.75

>

Vua =

0.4875

5.00

kips

[Satisfactory]

(for built-up grout pads, first factor shall be multiplied by 0.8, ACI 318 D.6.1.3)
CHECK CONCRETE BREAKOUT STRENGTH OF GOVERNING ANCHOR FOR SHEAR LOAD (ACI 318, D.6.2.1b)

l 0.2
IV cb I AV \ ec , N\ cd ,V\ c ,VV b I1.0\ ec ,V1.0\ c ,V 7 d f 'c 1.5hef
d
AVo

71.555 k

where :

>

Vua =

5.00

0.75

kips

1.5

[Satisfactory]

\ ec,V

=
=

1.0, for no eccentricity in the connection.

\ c,V

1.0, for location where concrete cracking is likely to occur.

0.75

0.5625

l term is load bearing length of the anchor for shear, not to exceed 8d.
CHECK CONCRETE BREAKOUT STRENGTH OF ALL ANCHORS FOR SHEAR LOAD : (ACI 318, D.6.2.1b)

l 0.2
AV
'
d f c 1.5h ef
IV cbg I AV \ ec , N\ cd ,V\ c ,VV b I
1.0
7
\
\
ec ,V
c ,V
2
d
AVo
4.5 1.5h ef

=
I

where :

77.826 k

0.75

>

Vu

0.75

1.5

[Satisfactory]
=

0.5625

CHECK PRYOUT STRENGTH FOR SHEAR LOAD ON GOVERNING ANCHOR (ACI 318, D.6.3.1)

IV cp I k cp A N \ ed , N\ c , N N b I k cp A N2 1.0\ c , N 24 f 'c h1.5


ef
9h ef
A No
=

44.052 k

where :

=
=

kcp

0.75
2.0

>

Vua =

5.00

0.75

kips

[Satisfactory]

0.5625

for hef > 2.5 in.

CHECK PRYOUT STRENGTH FOR SHEAR LOAD ON ALL ANCHOR (ACI 318, D.6.3.1)

IV cpg I k cp A N \ ed , N\ c , N N b I k cp A N2 1.0\ c , N 24 f 'c h1.5


ef

9h

A No

=
where :

ef

>

325.072 k

0.75

Vu

[Satisfactory]

0.75

0.5625

DETERMINE DESIGN SHEAR STRENGTH OF GOVERNING ANCHOR

IV n min IV s , IV cb , IV cp

10.281

REQUIRED EDGE DISTANCES AND SPACING TO PRECLUDE SPLITTING FAILURE :


Since headed cast-in-place anchors are not like to be highly torqued, the minimum cover requirements of ACI 318 Sec. 7.7 apply.
CoverProvd

>

CoverReqd

[Satisfactory]

(cont'd)
CHECK TENSION AND SHEAR INTERACTION OF GOVERNING ANCHORS : (ACI 318, D.7)
Since

Nua,2
<

INn and

V ua,2
<

IVn the full tension design strength is permitted.

The interaction equation may be used

N ua ,2 V ua ,2

IV n

INn

0.26

1.2

[Satisfactory]

Sum m ary of Dim ensional Properties of Anchors


Anchor
Diameter
( in )
0.250
0.375
0.500
0.625
0.750
0.875
1.000
1.125
1.250
1.375
1.500
1.750
2.000

1/4
3/8
1/2
5/8
3/4
7/8
1
1 1/8
1 1/4
1 3/8
1 1/2
1 3/4
2

Gross
Area of
Anchor
( in2 )
0.049
0.110
0.196
0.307
0.442
0.601
0.785
0.994
1.227
1.485
1.767
2.405
3.142

Effective
Bearing Area of Heads, Nuts, and Washers
Area of
( Ab ) ( in2 )
Threaded
Anchor
Heavy
Heavy Hardened
Square
Hex
( in2 )
Square
Hex
Washers
0.032
0.142
0.201
0.117
0.167
0.258
0.078
0.280
0.362
0.164
0.299
0.408
0.142
0.464
0.569
0.291
0.467
0.690
0.226
0.693
0.822
0.454
0.671
1.046
0.334
0.824
1.121
0.654
0.911
1.252
0.462
1.121
1.465
0.891
1.188
1.804
0.606
1.465
1.855
1.163
1.501
2.356
0.763
1.854
2.291
1.472
1.851
2.982
0.969
2.288
2.773
1.817
2.237
3.682
1.160
2.769
3.300
2.199
2.659
4.455
1.410
3.295
3.873
2.617
3.118
5.301
1.900
4.144
6.541
2.500
5.316
7.903

CHECK BASE PLATE THICKNESS (AISC Guide - 1, Eq. 3.3.14a)

t reqD

1.5m

1.73

in
7

Fy
[Satisfactory]

1.75

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Group of Tension Fasteners Near an Edge with Eccentricity Based on ACI 318-08

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH
SPECIFIED STRENGTH OF FASTENER

fc '

ksi

futa

60

ksi

(The strength of most fastenings is likely to be controlled by the embedment strength rather
than the steel strength, so it is usually economical to use ASTM A307 Grade A fastener.)
Nua,1

FACTORED DESIGN LOAD


EFFECTIVE EMBEDMENT DEPTH

11.7

hef

4.5

in

0.5

in

FASTENER DIAMETER
FASTENER HEAD TYPE

Heavy Square

( 1=Square, 2=Heavy Square, 3=Hex, 4=Heavy Hex, 5=Hardened Washers )


ECCENTRICITY

in

FASTENER CENTER-TO-CENTER SPACING

in

DIST. FR. THE OUTER FASTENERS TO EDGE

in

SEISMIC LOAD ? (ACI 318 D3.3)

No

ANALYSIS
TOTAL NUMBER OF FASTENERS

EFFECTIVE AREA OF FASTENER

Ase

0.142

in2

Ab

0.569

in2, ( or determined from manufacture's catalogs.)

BEARING AREA OF HEAD

[THE FASTENER DESIGN IS ADEQUATE.]

CHECK HIGHTEST TENSILE STRENGTH : (ACI 318, D.5.1.2)

I Ase f uta

I N s ,1stud

>

6.390 k

N ua ,max,1stud

[Satisfactory]

where :

0.75

0.75

N u s  2e
ns

4.875 k

, (ACI 318-08 D.4.4 & D.3.3.3)

CHECK CONCRETE BREAKOUT STRENGTH : (ACI 318, D.5.2.1)

I N cbg

AN
AN 1
I
\ ec , N\ ed , N\ c, N N b I
2
9h ef 1  2e
A No

3h ef

where :

>

11.773 k

0.75

0.3c
' 1.5
0.7 
\ c , N 24 f c h ef
1.5h ef

Nua

[Satisfactory]
1

0.75

\c,N term is 1.0 for location where concrete cracking is likely to occur.
CHECK PULLOUT STRENGTH OF SINGLE STUD : (ACI 318, D.5.3.1)

I N pn I\ cp , N Ab8 f 'c

>

13.656 k

Nua =

4.875

k, (ACI 318, D.3.3.6)

[Satisfactory]
where :

0.75

0.75

\cp,N term is 1.0 for location where concrete cracking is likely to occur.
EVALUATE SIDE-FACE BLOWOUT : (ACI 318, D.5.4.1)
c

>

0.4 hef

[Satisfactory]

Since this fastener is located far from a free edge of concrete (c > 0.4 hef ) this type of failure mode is not applicable.
REQUIRED EDGE DISTANCES AND SPACING TO PRECLUDE SPLITTING FAILURE :
Since a welded, headed fastener is not torqued, the minimum cover requirements of ACI 318 Sec. 7.7 apply.
CoverProvd

>

CoverReqd

[Satisfactory]

Summary of Dimensional Properties of Fasteners


Fastener
Diameter
( in )
0.250
0.375
0.500
0.625
0.750
0.875
1.000
1.125
1.250
1.375
1.500
1.750
2.000

1/4
3/8
1/2
5/8
3/4
7/8
1
1 1/8
1 1/4
1 3/8
1 1/2
1 3/4
2

Gross
Area of
Fastener
( in2 )
0.049
0.110
0.196
0.307
0.442
0.601
0.785
0.994
1.227
1.485
1.767
2.405
3.142

Effective
Area of
Threaded
Fastener
( in2 )
0.032
0.078
0.142
0.226
0.334
0.462
0.606
0.763
0.969
1.160
1.410
1.900
2.500

Square
0.142
0.280
0.464
0.693
0.824
1.121
1.465
1.854
2.288
2.769
3.295
-

Bearing Area of Heads, Nuts, and Washers


( Ab ) ( in2 )
Heavy
Heavy
Hardened
Hex
Square
Hex
Washers
0.201
0.117
0.167
0.258
0.362
0.164
0.299
0.408
0.569
0.291
0.467
0.690
0.822
0.454
0.671
1.046
1.121
0.654
0.911
1.252
1.465
0.891
1.188
1.804
1.855
1.163
1.501
2.356
2.291
1.472
1.851
2.982
2.773
1.817
2.237
3.682
3.300
2.199
2.659
4.455
3.873
2.617
3.118
5.301
4.144
6.541
5.316
7.903

Technical Reference:
1. Ronald Cook, "Strength Design
of Anchorage to Concrete," PCA,
1999.

PROJECT :
CLIENT :
JOB NO. :
DATE :
Single Fastener in Tension and Shear Near an Edge Based on ACI 318-08

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


fc'

ksi

futa

60

ksi

CONCRETE STRENGTH
SPECIFIED STRENGTH OF FASTENER

(The strength of most fastenings is likely to be controlled by the embedment strength rather
than the steel strength, so it is usually economical to use ASTM A307 Grade A fastener.)
FACTORED DESIGN TENSION LOAD

Nua,1

2.47

FACTORED DESIGN SHEAR LOAD

Vua,1

hef

in

0.5

EFFECTIVE EMBEDMENT DEPTH


FASTENER DIAMETER
FASTENER HEAD TYPE

in

Hex

( 1=Square, 2=Heavy Square, 3=Hex, 4=Heavy Hex, 5=Hardened Washers )


c

DIST. BETWEEN THE FASTENER AND EDGE

SEISMIC LOAD ? (ACI 318 D3.3)

[THE FASTENER DESIGN IS ADEQUATE.]

in

Yes

ANALYSIS
EFFECTIVE AREA OF FASTENER
BEARING AREA OF HEAD

Ase

0.142

in2

Ab

0.291

in2, ( or determined from manufacture's catalogs.)

CHECK FASTENER TENSILE STRENGTH (ACI 318, D.3.3.6):

INs

I n Ase f uta
I

where :

4.793 k

0.75

0.75

Nua =

0.5625 , (ACI 318-08 D.4.4 & D.3.3.3)

4.793

[Satisfactory]

CHECK CONCRETE BREAKOUT STRENGTH : (ACI 318, D.5.1.2)

0.3c
'
24 f c h1.5
I N cb I A N \ ed , N\ c , N N b I A N2 0.7 
\
ef
9h ef 1.5hef c, N
A No
=
where :

>

10.827 k

0.75

Nua

[Satisfactory]

0.75

0.5625

\c,N term is 1.0 for location where concrete cracking is likely to occur.
CHECK PULLOUT STRENGTH : (ACI 318, D.5.3.1)

I N pn I\ cp, N Ab8 f 'c


where :

>

5.238 k

0.75

0.75

Nua

[Satisfactory]

0.5625

\cp,N term is 1.0 for location where concrete cracking is likely to occur.
CHECK SIDE-FACE BLOWOUT STRENGTH : (ACI 318, D.5.4.1)

I N sb I 160c Ab f 'c
where :

>

18.423 k

0.75

0.75

Nua

[Satisfactory]

0.5625

DETERMINE DESIGN TENSILE STRENGTH :

I N n min I N s , I N cb , I N pn , I N sb

4.793

CHECK FASTENER SHEAR STRENGTH : (ACI 318, D.6.1.2b & D.3.3.6)

IV s I n0.6 Ase f ut
where :

2.492

0.65

k
0.75

Vua =

0.4875

2.492

[Satisfactory]

(for built-up grout pads, first factor shall be multiplied by 0.8, ACI 318 D6.1.3)
CHECK CONCRETE BREAKOUT STRENGTH FOR SHEAR LOAD : (ACI 318, D.6.2.1a)

IV cb
where :

l 0.2

A
A
V
V
I \ cd ,V\ c,VV b I \ cd ,V\ c,V 7 d f c' c1.5
d

AVo
AVo

0.75

0.75

3.923 k

>

0.5625

\c,V term is 1.0 for location where concrete cracking is likely to occur.
AV / AVo and \cd,V terms are 1.0 for single shear fastener not influenced by more than one free edge.
l term is load bearing length of the anchor for shear, not to exceed 8d.

Vua

[Satisfactory]

(Cont'd)
CHECK PRYOUT STRENGTH FOR SHEAR LOAD : (ACI 318, D.6.3.1)

0.3c
' 1.5
IV cp I k cp A N \ ed , N\ c , N N b I k cp A N2 0.7 
\ c , N 24 f c h ef
9hef 1.5h ef
A No
=
where :

>

21.654 k

0.75

Vua

[Satisfactory]

0.75

0.5625

\c,N term is 1.0 for location where concrete cracking is likely to occur.

kcp

2.0

for hef > 2.5 in.

DETERMINE DESIGN SHEAR STRENGTH :

IV n min IV s , IV cb , IV cp

2.492

CHECK TENSION AND SHEAR INTERACTION : (ACI 318, D.7)


Since

Nua,1

>

INn and

Vua,1

>

IVn the full design strength is not permitted.

The interaction equation must be used

N ua ,1 V ua ,1

I N n IV n

0.92

<

1.2

[Satisfactory]

Summary of Dimensional Properties of Fasteners


Fastener
Diameter
( in )
0.250
0.375
0.500
0.625
0.750
0.875
1.000
1.125
1.250
1.375
1.500
1.750
2.000

1/4
3/8
1/2
5/8
3/4
7/8
1
1 1/8
1 1/4
1 3/8
1 1/2
1 3/4
2

Effective
Gross
Area of
Bearing Area of Heads, Nuts, and Washers
( Ab ) ( in2 )
Area of Threaded
Fastener Fastener
Heavy
Heavy Hardened
Square
Hex
( in2 )
( in2 )
Square
Hex
Washers
0.049
0.032
0.142
0.201
0.117
0.167
0.258
0.110
0.078
0.280
0.362
0.164
0.299
0.408
0.196
0.142
0.464
0.569
0.291
0.467
0.690
0.307
0.226
0.693
0.822
0.454
0.671
1.046
0.442
0.334
0.824
1.121
0.654
0.911
1.252
0.601
0.462
1.121
1.465
0.891
1.188
1.804
0.785
0.606
1.465
1.855
1.163
1.501
2.356
0.994
0.763
1.854
2.291
1.472
1.851
2.982
1.227
0.969
2.288
2.773
1.817
2.237
3.682
1.485
1.160
2.769
3.300
2.199
2.659
4.455
1.767
1.410
3.295
3.873
2.617
3.118
5.301
2.405
1.900
4.144
6.541
3.142
2.500
5.316
7.903

Technical Reference:
1. Ronald Cook, "Strength Design
of Anchorage to Concrete," PCA,
1999.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Group of Tension and Shear Fasteners Near Two Edges Based on ACI 318-08

INPUT DATA & DESIGN SUMMARY


fc'

ksi

futa

58

ksi

CONCRETE STRENGTH
SPECIFIED STRENGTH OF FASTENER

(The strength of most fastenings is likely to be controlled by the embedment strength rather
than the steel strength, so it is usually economical to use ASTM A307 Grade A fastener.)
FACTORED DESIGN TENSION LOAD

Nua,1

FACTORED DESIGN SHEAR LOAD

Vua,1
hef
d

EFFECTIVE EMBEDMENT DEPTH


FASTENER DIAMETER

10

20

in

in

Heavy Hex

FASTENER HEAD TYPE

( 1=Square, 2=Heavy Square, 3=Hex, 4=Heavy Hex, 5=Hardened Washers )


FASTENER CENTER-TO-CENTER SPACING

in

DIST. BETWEEN THE FASTENER AND EDGE

c1

14

in

DIST. BETWEEN THE FASTENER AND EDGE

c2

in

SEISMIC LOAD ? (ACI 318 D3.3)

Yes
[THE FASTENER DESIGN IS ADEQUATE.]

ANALYSIS
NUMBER OF FASTENERS
EFFECTIVE AREA OF FASTENER
BEARING AREA OF HEAD

Ase

0.606

in2

Ab

1.501

in2, ( or determined from manufacture's catalogs.)

CHECK THE FASTENERS TENSILE STRENGTH : (ACI 318, D.5.1.2 & D.3.3.6)

INs

I n Ase f uta
I

where :

39.542 k

0.75

0.75

>

Nua =

0.5625 , (ACI 318-08 D.4.4 & D.3.3.3)

25.000

[Satisfactory]

CHECK CONCRETE BREAKOUT STRENGTH : (ACI 318, D.5.2.1)

0.3
I N cbg I A N \ ec , N\ ed , N\ c , N N b I A N2 \ ec, N 0.7  c min \ c , N 24 f 'c h1.5
ef
9h ef 1.5h ef
A No
=
where :

>

33.919 k

0.75

Nua

[Satisfactory]

0.75

0.5625

\ec,N term is 1.0 for no eccentricity in the connection.


\c,N term is 1.0 for location where concrete cracking is likely to occur.
CHECK PULLOUT STRENGTH : (ACI 318, D.5.3.1)

I N pn I n\ cp , N Ab8 f 'c
where :

>

54.036 k

0.75

0.75

Nua

[Satisfactory]

0.5625

\cp,N term is 1.0 for location where concrete cracking is likely to occur.
CHECK SIDE-FACE BLOWOUT STRENGTH : (ACI 318, D.5.4.1)
cmin

>

0.4 hef

[Satisfactory]

Since this fastener is located far from a free edge of concrete (c > 0.4 hef ) this type of failure mode is not applicable.
DETERMINE DESIGN TENSILE STRENGTH :

I N n min I N s , I N cb , I N pn

33.919

CHECK Fasteners SHEAR STRENGTH : (ACI 318, D.6.1.2b & D.3.3.6)

IV s I n0.6 Ase f ut
where :

=
0.65

>

20.562 k
x

0.75

Vua =

7.500

[Satisfactory]

0.4875
(for built-up grout pads, first factor shall be multiplied by 0.8, ACI 318 D6.1.3)

CHECK CONCRETE BREAKOUT STRENGTH FOR SHEAR LOAD : (ACI 318, D.6.2.1b)

(Cont'd)

l
1.5c1 1.5c1  s  c 2
c2

IV cbg I AV \ ec ,V\ cd ,V\ c ,V V b I


\ ec ,V 0.7  0.3
\ c ,V 7
2
4.5c1
1.5c1

AVo
d
=
I

where :

>

14.433 k

0.75

Vua

0.2

'
f c c11.5

[Satisfactory]

0.75

0.5625

\cp,N term is 1.0 for no eccentricity in the connection.


\c,V term is 1.0 for location where concrete cracking is likely to occur.
l term is load bearing length of the anchor for shear, not to exceed 8d.
CHECK PRYOUT STRENGTH FOR SHEAR LOAD : (ACI 318, D.6.3.1)

0.3
IV cpg I k cp A N \ ed , N\ c , N N b I k cp A N2 0.7  c min \ c , N 24 f c' h1.5
ef
1.5h ef
9hef
A No
=
where :

>

67.838 k

0.75

Vua

[Satisfactory]

0.75

0.5625

\c,N term is 1.0 for location where concrete cracking is likely to occur.

kcp

2.0

for hef > 2.5 in.

DETERMINE DESIGN SHEAR STRENGTH :

IV n min IV s , IV cb , IV cp

14.433

REQUIRED EDGE DISTANCES AND SPACING TO PRECLUDE SPLITTING FAILURE :


Since headed cast-in-place fasteners are not like to be highly torqued, the minimum cover requirements of ACI 318 Sec. 7.7 apply.

>

CoverProvd

CoverReqd

[Satisfactory]

CHECK TENSION AND SHEAR INTERACTION : (ACI 318, D.7)


Since

Nua,1

>

INn and

Vua,1

>

IVn the full design strength is not permitted.

The interaction equation must be used

N ua ,1 V ua ,1

I N n IV n

0.50

<

1.2

[Satisfactory]

Summary of Dimensional Properties of Fasteners


Fastener
Diameter
( in )
0.250
0.375
0.500
0.625
0.750
0.875
1.000
1.125
1.250
1.375
1.500
1.750
2.000

1/4
3/8
1/2
5/8
3/4
7/8
1
1 1/8
1 1/4
1 3/8
1 1/2
1 3/4
2

Effective
Gross
Area of
Bearing Area of Heads, Nuts, and Washers
( Ab ) ( in2 )
Area of Threaded
Fastener Fastener
Heavy
Heavy Hardened
Square
Hex
( in2 )
( in2 )
Square
Hex
Washers
0.049
0.032
0.142
0.201
0.117
0.167
0.258
0.110
0.078
0.280
0.362
0.164
0.299
0.408
0.196
0.142
0.464
0.569
0.291
0.467
0.690
0.307
0.226
0.693
0.822
0.454
0.671
1.046
0.442
0.334
0.824
1.121
0.654
0.911
1.252
0.601
0.462
1.121
1.465
0.891
1.188
1.804
0.785
0.606
1.465
1.855
1.163
1.501
2.356
0.994
0.763
1.854
2.291
1.472
1.851
2.982
1.227
0.969
2.288
2.773
1.817
2.237
3.682
1.485
1.160
2.769
3.300
2.199
2.659
4.455
1.767
1.410
3.295
3.873
2.617
3.118
5.301
2.405
1.900
4.144
6.541
3.142
2.500
5.316
7.903

Technical Reference:
1. Ronald Cook, "Strength Design
of Anchorage to Concrete," PCA,
1999.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Single Tension Fastener Away from Edges Based on ACI 318-08

INPUT DATA & DESIGN SUMMARY


fc'

ksi

futa

60

ksi

CONCRETE STRENGTH
SPECIFIED STRENGTH OF FASTENER

(The strength of most fastenings is likely to be controlled by the embedment strength rather
than the steel strength, so it is usually economical to use ASTM A307 Grade A fastener.)
FACTORED DESIGN LOAD

Nua,1

hef

in

0.5

in

EFFECTIVE EMBEDMENT DEPTH


FASTENER DIAMETER
FASTENER HEAD TYPE

Heavy Square

( 1=Square, 2=Heavy Square, 3=Hex, 4=Heavy Hex, 5=Hardened Washers )


SEISMIC LOAD ? (ACI 318 D3.3)

[THE FASTENER DESIGN IS ADEQUATE.]

Yes

ANALYSIS
EFFECTIVE AREA OF FASTENER
BEARING AREA OF HEAD

Ase

0.142

in

Ab

0.569

in

CHECK FASTENER TENSILE STRENGTH : (ACI 318, D.5.1.2 & D.3.3.6)

INs
where :

I n Ase f uta
=

=
0.75

4.793 k
x

Nua =

0.5625 , (ACI 318-08 D.4.4 & D.3.3.3)

0.75

4.793 k

[Satisfactory]

CHECK CONCRETE BREAKOUT STRENGTH : (ACI 318, D.5.2.1)

I N cb I A N \ ed , N\ c , N N b I A N \ ed , N\ c , N 24 f c' h1.5
ef
A No
A No
where :

0.75

0.75

>

9.546 k

Nua

[Satisfactory]

0.5625

AN/Ano and \ed,N terms are 1.0 for single fasteners away form edges.
\c,N term is 1.0 for location where concrete cracking is likely to occur (i.e., bottom of the slab)
CHECK PULLOUT STRENGTH : (ACI 318, D.5.3.1)

I N pn I\ cp , N Ab8 f c'
where :

=
0.75

>

10.242 k
x

0.75

Nua

[Satisfactory]

0.5625

\cp,N term is 1.0 for location where concrete cracking is likely to occur.
EVALUATE SIDE-FACE BLOWOUT :
Since this fastener is located far from a free edge of concrete (c > 0.4 hef ) this type of failure mode is not applicable.
REQUIRED EDGE DISTANCES AND SPACING TO PRECLUDE SPLITTING FAILURE :
Since this fastener is located far from a free edge of concrete (c>0.4hef ) this type of failure mode is not applicable.

Summary of Dimensional Properties of Fasteners


Effective
Fastener

Gross

Area of

Diameter

Area of

Threaded

( in )

Fastener Fastener
( in2 )
( in2 )

Bearing Area of Heads, Nuts, and Washers


( Ab ) ( in2 )
Square

Heavy
Square

Hex

Heavy

Hardened

Hex

Washers

0.250

1/4

0.049

0.032

0.142

0.201

0.117

0.167

0.258

0.375

3/8

0.110

0.078

0.280

0.362

0.164

0.299

0.408

0.500

1/2

0.196

0.142

0.464

0.569

0.291

0.467

0.690

0.625

5/8

0.307

0.226

0.693

0.822

0.454

0.671

1.046

of Anchorage to Concrete," PCA,

0.750

3/4

0.442

0.334

0.824

1.121

0.654

0.911

1.252

1999.

0.875

7/8

0.601

0.462

1.121

1.465

0.891

1.188

1.804

1.000

0.785

0.606

1.465

1.855

1.163

1.501

2.356

1.125

1 1/8

0.994

0.763

1.854

2.291

1.472

1.851

2.982

1.250

1 1/4

1.227

0.969

2.288

2.773

1.817

2.237

3.682

1.375

1 3/8

1.485

1.160

2.769

3.300

2.199

2.659

4.455

1.500

1 1/2

1.767

1.410

3.295

3.873

2.617

3.118

5.301

1.750
2.000

1 3/4
2

2.405
3.142

1.900
2.500

4.144
5.316

6.541
7.903

Technical Reference:
1. Ronald Cook, "Strength Design

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Concrete Beam Design, for New or Existing, Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
f 'c =

ksi

MAIN

fy =

60

ksi

STIRRUP

fy =

60

ksi

1000

ft-k

CONCRETE STRENGTH
REBAR STRENGTH

FACTORED BENDING MOMENT

Mu =

FACTORED SHEAR FORCE

Vu =

230

kips

FACTORED TORSIONAL MOMENT

Tu =

36.5

ft-k

SECTION DIMENSIONS

bw =

24

in

h=

48

in

hf =

in

b=

88

in, (ACI 318-08 8.12.2, 11.5.1.1, & 13.2.4)

COMPRESSION REINFORCEMENT
TENSION REINFORCEMENT
SHEAR REINFORCEMENT

4
6
4

THE DESIGN IS ADEQUATE.

#
#
legs #

7
9
4

12

in o.c.

ANALYSIS
CHECK FLEXURAL CAPACITY
o =

fC=

'

2 0.85 f C

0.85 f

0.85 f c'
A s' f s'

, E c = 57 f C , E s = 29000ksi
'

Ec
'
C

c = 0.003

2 c c
o
o

Fc

, for 0 < c < o

Parabolic

0.85 f C , for c o
'

fS=

Asfy

s E s , for s t
f y , for s > t

Cover =

1.5

in, (ACI 318-08 7.7.1)

d=
d' =
=

45.44
2.44
0.90

in
in
, (ACI 318-08 R9.3.2)

c,max =

0.0004

s,max =

0.0050

, (ACI 318-08 10.3.4)

Mn =

1193.23

ft-k

prov'd =

>

Mu

230.0
where

kips

Av
s

= MAX
Re qD

3.99
346.99

dc =

1.38

in

'
c

168.93

kips

where

A = MIN

B = MIN

V ud
Mu

2
, for

V c
2

V u V c

173.55

, 100 =

'
c

, 1.0 =

V u V c
, for V c V u
df y
=

0.586

in2 / ft

<

Av
s

0.800

22

>
S=
[Satisfactory]

in2 / ft

[Satisfactory]

Pr ovD

Check spacing limits for shear reinforcement (ACI 11.4.5)

Vs=

V u V c

, (ACI 318 10.5)

kips

V C = (1.9 A + 2500 wB ) b wd =

V c

0.75 f 'c b w
50b w
,
fy
fy

, (ACI 318 R10.3.5)

[Satisfactory]

Check shear reinforcement (ACI, 11.4)

0 , for V u <

c=
Fc =

V C = 2b wd
633.5
0.75

0.0188

Determine concrete capacity (ACI, 11.2.1.1 or 11.2.2.1)

'
c

<
=

max =

<

>
min =
0.0039
[Satisfactory]
in, by pure math method

[Satisfactory]

CHECK SHEAR CAPACITY


Check section limitation (ACI, 11.4.7.9)

V u 10 b wd

0.0055

0.00

kips, (ACI 11.1.1)

d
'
, 24) for V s 4b wd f c
2
=
S max, shear
d
'
MIN (
, 12) for V s > 4b wd f c
4
MIN (

12

in

kips ,<== applicable

77.46

0.871

(cont'd)
CHECK TORSION CAPACITY
Check section limitation (ACI, 11.5.3.1)
2

Vu
b wd

T u Ph
+
1.7 A2
oh

0.215

<

where

V C + 8 f 'c
b wd
0.581

0.75

(ACI, 9.3.2.3)

Ph =

258

Aoh =

1,287

in, (perimeter of centerline of outermost closed


transverse torsional reinforcement.)
in2 (area enclosed by centerline of the outermost

[Satisfactory]

closed transverse torsional reinforcement.)

Check if torsional reinforcement required (ACI, 11.5.1)

Tu

be = MIN(h-hf , 4hf) =

where

Acp
P cp

'

fc

36.5
<
44.7
ft-k
Torsional reinforcement NOT reqD.

Pcp =

160

Acp =

1,216

32

in, (one side, ACI, 11.5.1.1)

in, (outside perimeter of the concrete cross


section.)
in2 (area enclosed by outside perimeter of
concrete cross section.)

Check the max factored torque causing cracking (ACI, 11.5.2.2)

T u 4

Acp
P cp

'
c

36.5
<
179.0
Reduction of the torsional moment can occur.
Determine the area of one leg of a closed stirrup (ACI, 11.5.3.6)

At =
Tu
s 2 A0 f

=
yv

Tu
1.7 A0 h f

0.00

in / ft

yv

Determine the corresponding area of longitudinal reinforcement (derived from ACI, 11.5.3.7 & 11.5.5.3)

A L = MAX

f
At
Ph
s
f

yv

yL

'
f
5 Acp f c
Ph
f yL
f

yv

MAX

yL

Determine minimum combined area of longitudinal reinforcement


2
in
0.00
<
actual

AL, top = As' +0.5AL =


AL, bot = As +0.5AL =

5.03

in

<

actual

At
25b w
,
s
f yv

0.00

in

[Satisfactory]
[Satisfactory]

Determine minimum diameter for longitudinal reinforcement (ACI, 11.5.6.2)


dbL = MAX(0.042 S, 3/8) =

0.50

in

<

0.88

in

[Satisfactory]

Determine minimum combined area of stirrups (ACI, 11.5.5.2 & 11.5.6.1)


in2 / ft
0.40
>
MAX [ 0.75(fc')0.5bw/fyv, 50bw/fyv] =

0.24

Smax, tor = MIN[(Ph/8, 12) =

[Satisfactory]

(Av+2At) / S =

SreqD = MIN(Smax,shear , Smax,tor) =

12

in
12

in

>

actual

[Satisfactory]

in2 / ft

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Design for Concrete Beam with Penetration Based on ACI 318-08


INPUT DATA
f 'c

ksi

Mu =

305.9

Main Bar fy

60

ksi

Vu =

40

Stirrup fy

40

ksi

b=
h=

30
26

in, (ACI 8.10.2)


in

Top bars

bw =

20

in

Bot bars

hf =
x=
D=

5
10
10

in
in
in

Stirrup size
No. of legs

==>
=

3
2

DESIGN SUMMARY
Main bar top (Compressive Reinf.) :
Main bar bottom (Tensile Reinf.) :
FLEXURAL ANALYSIS
o =

ft-k

2 0.85 f

'
C

, E c = 57

Ec
0.85 f

'
C

0.85 f

'
C

sE s ,

in o.c.
d (optional) =

Use 2 # 5
Use 5 # 7 ( 1 layer )

c
c

o
o

for 0 < c < o

for c o
for s y

A's =

0.6

min =

0.0035

<

proD =

max =

0.0243

>

[Satisfactory]

23.7
2.2

in
in

Mn =

306.0

ft-kips

>

40.0
where

<
=

V C = 2b w ( d D )

145.2
0.75

for V u <

50b w
,
f y

=
Re qD

for

V u V c
,
(d D) f y
=

0.267

ft-kips

Determine concrete capacity (ACI 11.2.1.1 or 11.2.2.1)

'
c

'
fc=

38.71

[Satisfactory]

V C = (1.9 A + 2500 wB ) b w ( d D ) =

Check shear reinforcement (ACI 11.4)

0 ,

0.80
0.90

Mu =
305.9
[Satisfactory]

SHEAR ANALYSIS
Check section limitation (ACI 11.4.6.8)

in2

0.0063

1 =
=

d=
d' =

V u 10 b w ( d D )

The design is adequate.

Check flexural capacity (ACI 318, 10)


in2
3.0
As =

Av
s

in

Stirrups : Use # 3 @ 8 in. o.c. (2 legs)

, E s = 29000ksi

'
C

for s > y

f y ,

V c

where

2
V c
V u V c
2

A = MIN

B = MIN

V ud
Mu

'
c

41.17

k ,<== applicable

77.00

, 1.0 =

0.258

, 100 =

for V c V u
in2 / ft

<

Av
s

= 0.330

in2 / ft

[Satisfactory]

Pr ovD

Check spacing limits for shear reinforcement (ACI 11.4.4)

Vs=

V u V C

__
12.17

d
, 24) for V s 4b w ( d D ) f c'
2
=
S max, shear =
d
MIN (
, 12) for V s > 4b w ( d D ) f c'
4
MIN (

Page 147 of 533


524

11

>
S=
[Satisfactory]

10
in
(penetration diameter control)

PROJECT :

PAGE :

CLIENT :

DESIGN BY :

JOB NO. :

DATE :

REVIEW BY :

Deep Beam Design Based on ACI 318-08


INPUT DATA
f c'

REBAR YIELD STRESS

fy

FACTORED TOP LOAD

Pu

CONCRETE STRENGTH

ksi

60

ksi

145

(Input total load for non-point load condition.)


TOP LOAD LOCATION
a
=
5
ft
DEEP BEAM WIDTH
b
=
12
in
OVERALL BEAM DEPTH
H
=
42
in
CLEAR SPAN

Ln

12

ft

SUPPORT WIDTH

Lb

in

VERTICAL REINF.

in o.c.

HORIZONTAL REINF.

in o.c.

Layer

10

THE BEAM DESIGN IS ADEQUATE.


TENSION REINFORCEMENT

ANALYSIS
CHECK SECTION LIMITATION (ACI 318-08 11.7.3)
V u = P u Max(a , L n -a) / L n =
Vu / =

where

84.5833 k

10 f c b wd =
<
39.4 in
0.75 , (ACI 318-08 9.3.2.3)
'

112.778 kips

d=

259 kips

[Satisfactory]

CHECK MINIMUM FLEXURAL REINFORCEMENT (ACI 318-08 10.5.1)


As =

3.81

in

>

3b wd
f

MIN

'

fc

200b wd
=
fy

1.29

kips

[Satisfactory]

CHECK ANGLE LIMITATION OF STRUT-AND TIE MODEL (ACI 318-08 A.2.5)


o
o
25
left =
>
[Satisfactory]
33.27

right =

25.51

>

25

[Satisfactory]

CHECK STRUT CAPACITY (ACI 318-08 A.2)


R left =
R right =

83.95 kips
61.05 kips

F us,left =

100.41 kips

F us,right =

67.65 kips

s =

1.00

, (ACI 318-08 A.3.2.1)

f ce = 0.85 s f c ' =
A cs,left =

52.67

2.55
in

ksi

0.75

, (ACI 318-08 9.3.2.6)

A cs,right =

41.35

in

F ns,left = f ce A cs,left =

100.73

kips

>

F us,left

[Satisfactory]

F ns,right = f ce A cs,right =

79.08

kips

>

F us,right

[Satisfactory]

CHECK TIE CAPACITY (ACI 318-08 A.4)


F ut,left =

153.01 kips

<

F nt = f y A s =

171.45

kips

[Satisfactory]

F ut,right =

141.74 kips

<

F nt = f y A s =

171.45

kips

[Satisfactory]

CHECK NODAL ZONES CAPACITY (ACI 318-08 A.5)

n =

0.80

f ce = 0.85 n f c ' =

__
A nz = b L b =

, (ACI 318-08 A.3.5.2)


2.04

F nn = f ce A nz =

ksi

F un,left = R left =

83.9 kips

<

F nn

[Satisfactory]

F un,right = R right =

61.1 kips

<

F nn

[Satisfactory]

Page 148 of 533


524

96

in2

146.88 kips

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Non Deep Beam Design Based on ACI 318-11


DESIGN CRITERIA
This design method is, based on linear distribution of strain, for Non Deep Beam which cannot satisfy the requirements of ACI 318-11 10.7.1.
INPUT DATA & DESIGN SUMMARY
REBAR YIELD STRESS

fy =

60

ksi

CONCRETE STRENGTH

f c' =

ksi

H=
b=

48
12

OVERALL BEAM DEPTH


BEAM WIDTH

in
in

SD LEVEL SECTION LOADS


Pu =

280

kips, (horizontal axial force)

Mu =

300

ft-kips

Vu =

117

kips

VERTICAL REINF.
2
#
HORIZONTAL REINF.
2
#
TENSION REINFORCEMENT

in o.c.

@
1

6
Layer

in o.c.
3

THE BEAM DESIGN IS ADEQUATE.

ANALYSIS
CHECK FLEXURAL & AXIAL CAPACITY
Hc =
I=

1200

0.003

, (ACI 318-11 10.2.3)

, (for Pu & Mu, ACI 318-11 9.3.2)


in

1000

d=

0.836
46.9

800

cb =

27.7

in, (balance point between Tension


Controlled and Compression Controlled.)

280

kips

IPn =

879

IPn (k)

600

Pu =

400

<

kips, (ACI 318-11 10.3.6.1)

200

Mu =
0
-100

<
0

100

200

300

400

500

600

-200

300

ft-kips

IMn =

517

ft-kips, at Pu level.

[Satisfactory]

-400

IMn (ft-k)
CHECK SHEAR CAPACITY
Vu =
where

117
I =

kips
0.75

<
I Vn = I (Vs + Vc) =
(ACI 318-11 9.3.2.3)

Vc =

2 (fc')0.5A0 =

Vs =

MIN (d fy Av / s , 4Vc) =

31.5

118

kips, (ACI 318-11 11.1.1)

kips, (ACI 318-11 11.2.1)


126.2

kips, (ACI 318-11 11.4.7.2)

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Slab Punching Design Based on ACI 318-08


INPUT DATA
COLUMN WIDTH

c1

24

in

COLUMN DEPTH

c2

24

in

SLAB CONCRETE STRENGTH

fc'

ksi

SLAB THICKNESS

14

in

Td

10

in

DROP CAP / PANEL THICKNESS


BAR SIZE AT TOP SLAB
TRUSS BARS

10

each way

FACTORED AXIAL LOAD

Pu, col

400

kips

FACTORED BENDING LOAD

Mu, col

77.2

ft-kips

Pu, point

50

FACTORED POINT LOAD

kips

THE PUNCHING DESIGN IS ADEQUATE.

ANALYSIS
CHECK PUNCHING CAPACITY FOR COLUMN (ACI 318-08 SEC.11.4.7.4, 11.11.1.2, 11.11.6 & 13.5.3.2)

vc( psi ) = ( 2 + y ) f c' + Av f y sin / A p =


where

125

=
=

0.75 (ACI 318-08, Section 9.3.2.3 )


ratio of long side to short side of concentrated load =

T + Tc - 2 (0.5 db) -

b1

(c1 + d) =

44.73

in

b2

(c2 + d) =

44.73

in

b0

2b1 + 2b2 = 2(c1 + d) + 2(c2 + d) =

v =1

1
2
1+
3

4
d
y = MIN 2,
, 40 =

b
0
c

Av

=
=

b0 d
3.52

" cover =

178.9

P u ,col

0.5 v M u ,col b1

AP

20.73

in

in

4
62.85 ft

0.0

, (if truss bars used, y must be zero per ACI 11.11.3.1)

3709

in

in , total 4 sides

45

fy

60

ksi

CHECK PUNCHING CAPACITY FOR POINT LOAD (ACI 318-08 SEC.11.11.1.2, & 11.11.6)

P n, po int = 4 f 'c A p =
where

0.75

>

68.6 kips

T - 2" cover - 2 (0.5 db) =

b0

d=

Ap

b0 d

P u, point =

(ACI 318-08, Section 9.3.2.3 )


10.73

33.71 in
=

362

in

in

114

ksi

[Satisfactory]
1.00

0.4

b1
b2

d b3 d 2
b
J = 1 1 + + 3 2 =
6 b1
b1

Ap

v u ( psi ) =

>

ksi

50

kips

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Slab Punching Design Based on ACI 318-08


INPUT DATA
COLUMN DIAMETER

22

in

SLAB CONCRETE STRENGTH

fc'

ksi

SLAB THICKNESS

16

in

Td

in

DROP CAP / PANEL THICKNESS

10

Pu, col

400

kips

Pu, point

80

kips

BAR SIZE AT TOP SLAB


TRUSS BARS

FACTORED AXIAL LOAD

FACTORED POINT LOAD

each way

THE PUNCHING DESIGN IS ADEQUATE.

ANALYSIS
CHECK PUNCHING CAPACITY FOR COLUMN (ACI 318-08 SEC.11.4.7.4, 11.11.1.2, & 11.11.6)

P n, col = (2 or 4) f c' A p + MIN Av f y sin , 3b 0d

'

fc =

432.0

>
where

0.75

T + Tc - 2 (0.5 db) -

b0

(D + d) =

Ap

b0 d

Av

5.28

45

fy

60

ksi

kips, (if truss bars used, factor 2 apply per ACI 11.11.3.1)

P u, col =

400

kips

(ACI 318-08, Section 9.3.2.3 )

=
in

134.2

in

2783

in

" cover =

20.73

in

80

kips

CHECK PUNCHING CAPACITY FOR POINT LOAD (ACI 318-08 SEC.11.11.1.2, & 11.11.6)

P n, po int = 4 f 'c A p =
where

0.75

>

96.6 kips

T - 2" cover - 2 (0.5 db) =

b0

d=

Ap

b0 d

P u, point =

(ACI 318-08, Section 9.3.2.3 )


12.73

39.99 in
=

509

in

in

[Satisfactory]

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Coupling Beam Design Based on ACI 318-08 / IBC 2009

INPUT DATA
f c'

REBAR YIELD STRESS

fy

FACTORED SHEAR LOAD

Vu

CONCRETE STRENGTH

ksi

60

ksi

239

WIDTH

16

in

OVERALL DEPTH

72

in

COUPLING BEAM DEPTH

16

in

CLEAR SPAN

ft

DIAGONAL BARS, Ad

DIAGONAL TIES, Ash

HORIZONTAL BARS, Avh


VERTICAL TIES, Av

16

legs #

( 2 layers @ 10 in o.c. )
6

in o.c.

ANALYSIS
CHECK DIAGONAL BARS REQUIREMENT (ACI 318-08, 21.9.7.2 & 21.9.7.3)
L/h=

Vu

<
<

1.00

4
2

V n = 4 bh

<

'
c

291

[Coupling Beam Permitted]

CHECK DIAGONAL BARS (ACI 318-08, 21.9.7.4)


Vu

V n = MIN (2 f y Ad sin , 10bh f 'c ) =

<

240 k

[Satisfactory]

CHECK TIES AROUND DIAGONAL BARS (ACI 318-08, 21.4.4)


'

A sh = MAX

'

0.3sh c f c A g
1
fy
A ch

0.09 sh c f c
=
fy

0.384

in2

<

A sh, provd

[Satisfactory]

CHECK VERTICAL TIES (ACI 318-08, 11.7.5)

Av = 0.0015bs =

0.144

in

Av , provd

<

[Satisfactory]

CHECK HORIZONTAL BARS (ACI 318-08, 11.7.4)

Avh = 0.0025bh =

0.383

in

<

Av , provd

[Satisfactory]

DETERMINE LONGITUDINAL BARS (ACI 318-08, 10.5.1)

A s ,min = MAX

__

3bd f 'c
200bd
,
fy
f y

3.07

in

==> ( 4 #

longitudinal bars both top & bottom)

(Note: These bars are not recommended by SEAOC to be used, and are not shown in figure above.)

Page 151 of 533


524

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Coupling Beam Design Based on CBC 2001 / UBC 1997

INPUT DATA
fc '

REBAR YIELD STRESS

fy

FACTORED SHEAR LOAD

Vu

WIDTH
OVERALL DEPTH
CLEAR SPAN
DIAGONAL BARS, Ad

CONCRETE STRENGTH

DIAGONAL TIES, Ash

ksi

60

ksi

254

16

in

72

in

ft

16

legs #

HORIZONTAL BARS, Avh


VERTICAL TIES, Av

( 2 layers @ 10 in o.c. )
6

in o.c.

ANALYSIS
CHECK DIAGONAL BARS REQUIREMENT (SEC.1921.6.10.2)
L/d=

1.02

<

where

d=

70.25

Vu

<

4
in

V n = 4 bd f 'c =

284

[Coupling Beam Permitted]

CHECK DIAGONAL BARS (SEC.1921.6.10.2)


Vu

<

V n = MIN (2 f y A d sin , 10bd f 'c ) =

255 k

[Satisfactory]

CHECK TIES AROUND DIAGONAL BARS (SEC. 1921.4.4)


'

A sh = MAX

0.3sh c f c A g
1
fy
Ach

'

0.09 sh c f c
=
fy

0.384

in2

<

A sh, provd

[Satisfactory]

CHECK VERTICAL TIES (SEC. 1911.8.9)

Av = 0.0015bs =

0.144

in2

Av , provd

<

[Satisfactory]

CHECK HORIZONTAL BARS (SEC. 1911.8.10)

Avh = 0.0025bh =

0.383

in2

<

Av , provd

[Satisfactory]

DETERMINE LONGITUDINAL BARS (SEC. 1910.5.1)

__
'

3bd f c
200bd
,
A s ,min = MAX
fy
f y

3.07

in2

==> ( 4 #

longitudinal bars both top & bottom)

(Note: These bars are not recommended by SEAOC to be used, and are not shown in figure above.)

Page 152 of 533


524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Concrete Column Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc'

ksi

REBAR YIELD STRESS

fy

60

ksi

SECTION SIZE

Cx

40

in

Cy

36

in

FACTORED AXIAL LOAD

Pu

1700 k

Mu,x

1800 ft-k

Mu,y

100

ft-k

Vu,x

130

Vu,y =
COLUMN VERT. REINFORCEMENT
8
#
3
#
LATERAL REINF. OPTION (0=Spirals, 1=Ties)
LATERAL REINFORCEMENT
4 legs,#
3 legs,#

150
8
8
1
4
4

k
at x dir.
at y dir.
Ties
@
12
@
12

FACTORED MAGNIFIED MOMENT

FACTORED SHEAR LOAD

THE COLUMN DESIGN IS ADEQUATE.


(Total 22 # 8)
in o.c., at x dir.
in o.c., at y dir.

ANALYSIS
5000
4500
4000

3500
3000

Pn (k)

2500
2000

1500
1000
500
0
0

500

1000

1500

2000

2500

3000

3500

4000

Mn (ft-k)
Pn (k)
4315
4315
3724
3149
2700
2062
2041

AT AXIAL LOAD ONLY


AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT t = 0.002
AT BALANCED CONDITION
AT t = 0.005
AT FLEXURE ONLY

1104
0

Mn (ft-k)
0
1196
1744
2121
2305
2435
2461

o =

3463
2390

2 0.85 f

0.85 f

0.85 f

'
C

Ec
'
C

, E c = 57

'
C

2
2 c c ,
o o

, E s = 29000ksi
for 0 < c < o

'
C

, for c o

s E s , for s t
=
f
, for s > t

CHECK FLEXURAL & AXIAL CAPACITY

Pmax =F [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

4315 kips., (at max axial load, ACI 318-08, Sec. 10.3.6.2)

0.65 (ACI 318-08, Sec.9.3.2.2)

0.8

0.75 + ( t - 0.002 ) (50), for Spiral

0.65 + ( t - 0.002 ) (250 / 3), for Ties


where

Cb = d
d

Mn =

2826

>

Ag = 1440 in

c / (c + s)

0.656

max

0.08 (ACI 318-08, Section 10.9)

min

0.01 (ACI 318-08, Section 10.9)

Pu

17.38 in

[Satisfactory]

(ACI 318-08, Fig. R9.3.2)

t =

0.0021
40.0

in

Mu =

1803

ft-kips

provd

>

1700 kips

Ast =

D =

22.2 in

37.5 in, (ACI 7.7.1)


ft-kips @ Pu =

c =

0.003

Cover =

1.5

in, (ACI 318 7.7.1)

[Satisfactory]

0.012
[Satisfactory]

CHECK SHEAR CAPACITY (ACI 318-08 Sec. 11.1.1, 11.2.1, & 11.4.6.2)

Vn = (Vs + Vc)

(ACI 318-08 Sec. 11.1.1)

>
where

Vu

[Satisfactory]

0.75 (ACI 318-08 Sec. 9.3.2.3)

x
y

d
37.5
33.5

smax

16

smin

A0
1240
1240

Av
0.80
0.60

fy =

Vc = 2 (fc')0.5A0
192.1
192.1

(ACI 318-08, Section 7.10.5.2)

60

ksi

Vs = MIN (d fy Av / s , 4Vc)
150.0
100.5
sprovd

12

in
[Satisfactory]

Vn
257
219

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Magnified Moment Calculation for Concrete Column Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
EFFECTIVE LENGTH FACTOR

1.6

COLUMN UNSUPPORTED LENGTH

Lu

12

ft

LARGER FACTORED MOMENT

M2

200

ft-k

SMALLER FACTORED END MOMENT

M1

100

CONCRETE STRENGTH

fc'

ksi

COLUMN DIMENSIONS

h
b

=
=

20
20

in
in

FACTORED AXIAL LOAD

, (ACI 10.10.6.3 or 10.10.7.1)

ft-k, (positive if single curvature.)

Pu

400

SUMMATION FOR ALL VERTICAL LOADS IN THE STORY

Pu

1200

SUMMATION FOR ALL CRITICAL LOADS IN THE STORY

Pc

13600 k, (ACI Eq. 10-21)

THE MAGNIFIED MOMENT:

Mu

236.7

ft-k

, Sway

ANALYSIS
MAGNIFIED MOMENT - NONSWAY
r = 0.3 h =
6.0
k Lu / r =

>

38.4

in, ACI 10.11.2


34 - 12(M1 / M2) =

Ec = 57000 (fc')0.5 =

3605.0 ksi, ACI 8.5.1

Ig = b h3 / 12 =

13333

EI =

0.4 E c I g
1+ d

Pc =

0.4 E c I g
1 + 0.6

2EI =

( k Lu )2

= 0.25E c I g =

1E+07 k-in , ACI 10.10.6.1

2234.2 k, ACI Eq (10-14)

M2,min = MAX[ M2 , Pu (0.6+0.03 h) ] =

Cm
, 1.0 =
Pu
0.75P c

Mu, ns = ns M2, min =

< = = Slenderness effect must be considered. (ACI Eq 10-7)

in4

200

Cm = MAX[ 0.6 + 0.4 (M1 / M2, min) , 0.4 ] =

ns = MAX

28

210.2

1.05

ft-k, ACI 10.10.6.5


0.8

, ACI Eq(10-16)

, ACI Eq (10-12)

>

ft-k, ACI Eq (10-11)

1.05 M2 =

210.0

ft-k

[Unsatisfactory]

,(ACI 10.10.5.1)

The column is sway. See calculation as follows.


MAGNIFIED MOMENT - SWAY
k Lu / r =

s = MIN MAX

Ag = b h =

400
24.00

M2s = M2 =

200.0
5%

Mu, s = M2ns + s M2s =


Note:

22

1
, 1.0
Pu
1
0.75 P c

Lu / r =
M2ns =

>

38.4

< = = Slenderness effect must be considered. ACI Eq (10-6)

, 2.5 =

1.13

, ACI Eq (10-21)

in2

<

35 / [Pu / (fc' Ag)]0.5 =

70.00

[Satisfactory]

ft-k, as given
M2s =
236.7

10.0

ft-k, assumed conservatively

ft-k, ACI Eq (10-19)

For column subject to bending about both principal axis, the moment about each axis shall be magnified separately based
on the conditions corresponding to that axis.

__
Page 154 of 533
524

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :
Rectangular Concrete Column Design
INPUT DATA
f 'c

ksi

fy
x
y
Bar Size
No. of Asx

=
=
=
==>
=

60
48
32
11
8

ksi
in
in

No. of Asy
Total Bars

=
==>
=

DATE :

8 # 11

9
30 # 11
3.0%

PAGE :
DESIGN BY :
REVIEW BY :

9 # 11

Pu

1700

Mux

2900

ft-k

ex

20.5

in

Muy

1200

ft-k

ey

8.5

in

CHECK COLUMN CAPACITY BY THE BRESLER METHOD

Pn

Pu ( 0.80 )( 0.70 ) P o

1
P ox

1700.0

<

4407.9 ok

2428.6

1
1

P oy

<

M ny
M nx
+
1.0
M nox M noy

Po

3145.4 ok

1.199

>

1.0

NG

ANALYSIS

0.003

x DIRECTION

y DIRECTION

45.295
2.705
12.48
32

29.295
2.705
14.04
48

0.70

d
d'
As
b

=
=
=
=

in
in
2
in

Mn

4142.9 ft-k

1714.3 ft-k

0.85

Mno

5485.1 ft-k

3864.7 ft-k

Po

3820.9 k

5457.1 k

4.10078 in

3.70173 in

29612.2 psi

23425.7 psi

4034.01 ft-k

3052.89 ft-k

in

in
in
2
in
in

MOMENT STRENGTH (Pn=0)

c=

'
As f y As u E s +

'
c

'
s

1.7 1 f c' b

f s = E s u
'

( As f y A's u E s ) + 3.4 f b A E d

'

cd'
=
c

M n = 0.85 f c 1cb d
'

1c
2

+ As' f s ( d d ' ) =
'

AXIAL LOAD STRENGTH (Mn=0)


'
P o = 0.85 f c( A g A st ) + A st f y =

7871.28 k

7871.28 k

BALANCED CONDITION

ab =

u E s 1d
=
uE s + f y

'
f sb = u E s 1

22.7862 in

'
d uEs + f
d
uEs

60000 psi

__

'
'
'
P b = 0.85 f cb a b + As f sb A s f y =

'
M b = 0.85 f cb a b

h ab
h

+ A s' f 'sb
d ' As f
2 2
2

d
h =
2

Page 155 of 533


524

14.7372 in

60000 psi

2479.13 k

2405.11 k

5515.32 ft-k

3881.41 ft-k

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Circular Column Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc'

ksi

REBAR YIELD STRESS

fy

60

ksi

SECTION SIZE

20

in

FACTORED AXIAL LOAD

Pu

300

FACTORED MAGNIFIED MOMENT

Mu

160

ft-k

Vu =
FACTORED SHEAR LOAD
COLUMN VERT. REINFORCEMENT
8
#
LATERAL REINF. OPTION (0=Spirals, 1=Ties)
LATERAL REINFORCEMENT
#
4 @

20
6
1
12

Ties
in o.c.

THE COLUMN DESIGN IS ADEQUATE.

ANALYSIS

o =

900

2 0.85 f

'
C

, E c = 57

Ec

800
700

600

Pn (k)

0.85 f

400

c
c

o
o

, E s = 29000ksi

'
C

for 0 < c < o

, for c o
,
for s t
sE s
=
f y , for s > t
0.85 f

500

'
C

'
C

300
200

AT AXIAL LOAD ONLY


AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT t = 0.002
AT BALANCED CONDITION

100
0
0

50

100

150

200

250

Mn (ft-k)

AT t = 0.005
AT FLEXURE ONLY

Pn (k)
796
796
673
558
460
323
318
73
0

CHECK FLEXURAL & AXIAL CAPACITY

Pmax =F [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

796.34 kips., (at max axial load, ACI 318-08, Sec. 10.3.6.2)
Ag =

0.8

0.75 + ( t - 0.002 ) (50), for Spiral

Cb = d c / (c + s) =
d

Mn =

176

10.4

314
=

0.65 + ( t - 0.002 ) (250 / 3), for Ties


where

>

Pu

3.52

in2

0.65 (ACI 318-08, Sec.9.3.2.2)


in2
0.656

300

kips

c =

t =

0.0021
20.0

in

>

Mu =

160

ft-kips

provd

max

0.08 (ACI 318-08, Section 10.9)

min

0.01 (ACI 318-08, Section 10.9)

[Satisfactory]

(ACI 318-08, Fig. R9.3.2)

D =

in

17.6 in, (ACI 7.7.1)


ft-kips @ Pu =

Ast =

0.003

Cover =

1.5

in, (ACI 318 7.7.1)

[Satisfactory]

0.011
[Satisfactory]

CHECK SHEAR CAPACITY (ACI 318-08 Sec. 11.1.1, 11.2.1, & 11.4.6.2)

Vn = (Vs + Vc)

(ACI 318-08 Sec. 11.1.1)

>
where

Vu

[Satisfactory]
fy =

0.75 (ACI 318-08 Sec. 9.3.2.3)

d
17.6

smax

12

smin

A0
183

Av
0.40

Vc =

(ACI 318-08, Section 7.10.5.2)

2 (fc')0.5A0
25.8

60

ksi

Vs = MIN (d fy Av / s , 4Vc)
35.3
sprovd

12

in
[Satisfactory]

Vn
46

Mn (ft-k)
0
76
121
150
165
171
173
221
192

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Magnified Moment Calculation for Circular Column Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
EFFECTIVE LENGTH FACTOR

COLUMN UNSUPPORTED LENGTH

Lu

12

ft

LARGER FACTORED MOMENT

M2

200

ft-k

SMALLER FACTORED END MOMENT

M1

12

ft-k, (positive if single curvature.)

CONCRETE STRENGTH

fc'

ksi

COLUMN DIAMETER

20

in

FACTORED AXIAL LOAD

Pu

400

SUMMATION FOR ALL VERTICAL LOADS IN THE STORY

Pu

1200

SUMMATION FOR ALL CRITICAL LOADS IN THE STORY

Pc

13600 k, (ACI Eq. 10-21)

THE MAGNIFIED MOMENT:

Mu

200.0

ft-k

, (ACI 10.10.6.3 or 10.10.7.1)

, Nonsway

ANALYSIS
MAGNIFIED MOMENT - NONSWAY
r = 0.25 D =
5.0
k Lu / r =

<

28.8

in, ACI 10.11.2


34 - 12(M1 / M2) = 33.28 < = = Slenderness effect may be ignored. (ACI Eq 10-7)

Ec = 57000 (fc')0.5 =

3605.0 ksi, ACI 8.5.1

Ig = D4 / 64 =

7854

EI =

0.4 E c I g
1+ d

Pc =

0.4 E c I g
1 + 0.6

2EI =
2

in4

= 0.25E c I g =

7E+06 k-in , ACI 10.10.6.1

3369.1 k, ACI Eq (10-14)

( k Lu )

M2,min = MAX[ M2 , Pu (0.6+0.03 D) ] =

200

Cm = MAX[ 0.6 + 0.4 (M1 / M2, min) , 0.4 ] =

ns = MAX

Cm
, 1.0 =
Pu
0.75P c

Mu, ns = ns M2, min =

200.0

1.00

ft-k, ACI 10.10.6.5


0.624

, ACI Eq(10-16)

, ACI Eq (10-12)

<

ft-k, ACI Eq (10-11)

1.05 M2 =

210.0

ft-k

[Satisfactory]

,(ACI 10.10.5.1)

The column is nonsway. Ignore following calculations.


MAGNIFIED MOMENT - SWAY
k Lu / r =

s = MIN MAX

314

Lu / r =

28.80

M2s = M2 =

200.0

22

1
, 1.0
Pu
0.75 P c

Ag = D2 / 4 =

M2ns =

< = = Not apply

>

28.8

5%

Mu, s = M2ns + s M2s =

<

< = = Slenderness effect must be considered. ACI Eq (10-6)

, 2.5 =

1.13

, ACI Eq (10-21)

in2
35 / [Pu / (fc' Ag)]0.5 =

62.04

[Satisfactory]

ft-k, as given
M2s =
236.7

10.0

ft-k, assumed conservatively

ft-k, ACI Eq (10-19)

__
Page 157 of 533
524

PROJECT :
CLIENT :
JOB NO. :
DATE :
Design of Column Supporting Discontinuous System Based on ASCE 7-05 & ACI 318-08

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

fc' =

ksi

REBAR YIELD STRESS


COLUMN CLEAR HEIGHT
COLUMN SIZE

fy =
h =
c1 =

60
16
24

ksi
ft
in

c2 =

24

in

SEISMIC COEFFICIENT (Tab 12.2-1)

Cd =

AMPLIFICATION FACTOR (Tab 12.2-1)

0 =

2.5

DESIGN STORY DRIFT


COLUMN LOADS, ASD (ft-kips, kips)
Mtop
P
DL
40
0
LL
20
0
E/1.4
100
80

xe =

0.1

LONGITUDINAL REINFORCING
SECTION
LEFT
4
(d =
RIGHT

TOP
#
21.50
( 1 Layer)
4
#
( d = 21.50
( 1 Layer)

V
0
0
20

in

Mbot
0
0
80

BOTTOM
#
21.50
( 1 Layer)
4
#
( d = 21.50
( 1 Layer)

8
in )

4
(d =

8
in )

8
in )
8
in )

THE COLUMN DESIGN IS ADEQUATE.


TRANSVERSE REINFORCEMENT FOR CONFINEMENT
3 Legs #
4
@

in, o.c., full height (ACI 318-08 21.4.4.5)

ANALYSIS
DESIGN CRITERIA
1. since the column supported reaction from discontinued stiff member, ASCE 7-05 12.3.3.3 apply.
2. since the column is not part of the lateral force resisting system, ACI 318-08 21.13 apply.
3. since the column Ld required into top & 12" at least into footing per ACI 318-08 21.6.4.6, a fixed-fixed condition should be used.
DESIGN LOADS
U1 = 1.2 D + f1 L +1.0 0 Eh

U2 = (0.90.2SDS) D 1.0 0 Eh

, (ACI 318-08 21.13)

Pu =

417.6

kips

Mu,top =

280.0

ft-kips

Pu =

395.6

kips

Mu,top =

280.0

ft-kips

Vu =

70.0

kips

Mu,bot =

280.0

ft-kips

Vu =

70.0

kips

Mu,bot =

280.0

ft-kips

f1 =

0.5

U3 = 1.2 D + 1.6 L

SDS =

1.2

, (ACI 318-08 9.2.1)

Pu =

80.0

kips

Mu,top =

0.0

ft-kips

Vu =

0.0

kips

Mu,bot =

0.0

ft-kips

CHECK CAPACITY SUBJECTED TO BENDING AND AXIAL LOAD


LOADING

U1,top

U1,bot

U2,top

U2,bot

U3,top

U3,bot

Pu (kips)

417.6

417.6

395.6

395.6

80.0

80.0

Mu (ft-kips)

280.0

280.0

280.0

280.0

0.0

0.0

ns = Cm/[1-Pu/(0.75Pc)]
nsMu (ft-kips)
Mn (ft-kips) @ Pu

1.107

1.107

1.100

1.100

1.019

1.019

309.9

309.9

308.1

308.1

0.0

0.0

430.1

501.4

502.5

502.5

404.7

404.7

where

EI = 0.4EcIg / (1+d) = 0.25 EcIg


Pc = 2EI / (kLu)2

SUMMARY OF LOAD VERSUS MOMENT CAPACITIES (for ACI 318-08 10.2 & 10.3 only)
CAPACITY
AT AXIAL LOAD ONLY
AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT t = 0.002
AT BALANCED CONDITION
AT t = 0.005
AT FLEXURE ONLY

Pn (kips)
1047
1047
893
745
622
431
420
256
0

Mn (ft-kips)
0
175
272
336
376
425
428
537
405

Pn (kips)

(cont'd)

1200

1000

800

600

400

200

Mn (ft-kips)

0
0

100

200

300

400

500

600

All load points to be within capacity diagram.

[Satisfactory]

DETERMINE INDUCED MOMENT IN THE COLUMN

M col

6 E c I c u

where

h2

+ P =

273.6766 ft-kips, at top & bottom of column

E c = 57000 (fc')0.5 =

3122

ksi, ACI 318-08 8.5.1

I g = c1 c23 / 12 =

27648

in4

Ic =

Ig =

19354

0.7

in4 , ACI 318-08 9.5.2.3 & 10.11.1

u = Cd xe / I =

0.33

P = 0.9 PDL =

36

kips, ACI 318-08 21.13.3

= 0.5 u =

0.17

in, ACI 318-08 21.13.3

I =

1.5

, ASCE 7-05 (12.8-15)

CHECK REQUIREMENTS OF NOT PART OF THE LATERAL RESISTING SYSTEM


M u = 1.2 MDL + 1.0 MLL + Mcol =

273.6766 ft-kips
Mn =

<
Pu, max =

404.7

kips

[Satisfactory]

417.6
kips
>
0.1Agfc' =
172.8 kips
[Satisfactory]
Per ACI 318-08 21.13.4.3, the column shall satisfy ACI 318-08 21.6.3, 21.6.4, 21.6.5, and 21.7.3.1.

CHECK SECTION REQUIREMENTS (ACI 318-08 21.6.1)


cmin =MIN(c1, c2) =

24

cmin / cmax =

>

in

>

1.00

12

0.4

in

[Satisfactory]

[Satisfactory]

CHECK TRANSVERSE REINFORCING AT END OF COLUMN (ACI 318-08 21.6.4)


2
in
Ash =
0.60
>
MAX[ 0.09shcfc' / fyh , 0.3shc(Ag/Ach-1)fc' / fyh ] =
[Satisfactory]

where

0.47

s = MAX[MIN(c1/4, 6db, 4+(14-hx)/3, 6), 4] =


hc = c1 - 2Cover - dt =
Ach = (c1-3)(c2-3) =

20.5
441.0

in
5

in

in

CHECK FLEXURAL REINFORCING (ACI 318-08 21.6.1.1)

total = 0.018

>
<

min =
max =

0.010

[Satisfactory]

0.060

[Satisfactory]

CHECK SHEAR STRENGTH (ACI 318-08 21.6.4.6)


Ve = MAX[ (Mpr, left, top + Mpr, right,bot) / h , Vu,max] =

where

top,left =
bot,left =

0.006
0.006

120.8

kips

8(fc')0.5c2d =

<
<
>
>

169.6

[2(fc')0.5c2d + Avfyd / s] =

kips
158.5

min=MIN[3(fc')0.5/fy, 200/fy ]=
0.003
min =
0.003
[Satisfactory]

Mpr, left, top = 1.25Mn,col,max =

966

ft-kips

Mpr, right, bot = 1.25Mn,col,max =

966

ft-kips

Av =

[Satisfactory]
kips

[Satisfactory]

[Satisfactory]

0.75
0.6

, ACI 318-08 9.3.2.3


in2

DETERMINE SEISMIC TENSION DEVELOPMENT, Ld, INTO THE TOP PER ACI 318-08 21.6.4.6

L dh = MAX

db f
65

'
c

, 8d b , 6 in =

L d = MAX ( 3.5 L dh , 12 in ) =
where

59 db

db

1.0

17 db

59

17

in, (ACI 318-08 21.7.5.1)

in, (ACI 318-08 21.7.5.2)

in
, (1.2 for epoxy-coated, ACI 318-08 21.7.5.4 & 12.2.4)

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Corbel Design Based on IBC 09 / ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc'

ksi

REBAR YIELD STRESS

fy

60

ksi

FACTORED SHEAR LOAD

Vu

80

FACTORED TENSILE LOAD

N uc

40

WIDTH

15

in

EFFECTIVE DEPTH

20

in

OVERALL DEPTH

22

in

SHEAR SPAN

in

EDGE DEPTH

hc

12

in

PRIMARY REINFORCEMENT

CLOSED STIRRUPS

( spacing 4 in o.c. )

ANALYSIS
CHECK DIMENSIONAL REQUIREMENTS (ACI Sec. 11.8.1 & 11.8.2)
a/d =
Nuc / Vu =

0.50

hc =

12.00

<
<
>

0.20

[SATISFACTORY]

[SATISFACTORY]

0.5 d

[SATISFACTORY]

CHECK SECTION (ACI Sec. 11.8.3.2.1)

MIN (0.2I f 'cbd , 0.8I bd )

<

Vu

where

I =

= 180 k

[SATISFACTORY]

0.75

CHECK REINFORCEMENT
An

N
0.2V u
MAX uc ,

I f y
I f y

0.889

in2

A vf

Vu

IP f

(ACI Sec. 11.8.3.4)


where

Af

I =

in2

(ACI Sec. 11.7.4.3)


P =
1.4

0.75

'
Mu
0.85bd f c 1  1 
'

0.383
bd 2 f c

fy

1.270

2
= 0.373 in

M u V ua  N uc h  d

400

in-k

(ACI Sec. 10.2)

A sc

2 Avf
0.04 f 'c
MAX A f  An ,
 An ,
bd =

3
fy

1.735

in2

(ACI Sec. 11.8.3.5 & 11.8.5)

Ah

A sc  An
2

0.423

(ACI Sec. 11.8.4)

in2

<

Ah , provd

[SATISFACTORY]

0.660

in2

<

A s , provd

1.800

[SATISFACTORY]

in2

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Corbel Design Based on CBC 01 / ACI 318-95


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH
REBAR YIELD STRESS
FACTORED SHEAR LOAD
FACTORED TENSILE LOAD
WIDTH
EFFECTIVE DEPTH
OVERALL DEPTH
SHEAR SPAN
PRIMARY REINFORCEMENT
CLOSED STIRRUPS

fc'
fy
Vu
Nuc
b
d
h
a
3
3

=
=
=
=
=
=
=
=
#
#

5
60
100
40
15
20
22
4
7
3

ksi
ksi
k
k
in
in
in
in

( spacing 4 in o.c. )

ANALYSIS
CHECK DIMENSIONAL REQUIREMENTS (ACI Sec. 11.9.1 & 11.9.2)
<
a/d =
0.20
1
[SATISFACTORY]
Nuc / Vu =
<
1
[SATISFACTORY]
0.40
hc = 12.00
>
0.5 d [SATISFACTORY]
CHECK SECTION (ACI Sec. 11.9.3.2)
Vu

MIN (0.2 f cbd , 0.8 bd )


'

<

= 204 k

[SATISFACTORY]

CHECK REINFORCEMENT

An = MAX

N uc 0.2V u
,
fy
fy

0.784

in

Avf =

Vu

uf

'

Af =

in

(ACI Sec. 11.9.3.4)

0.85bd f c 1 1

1.401

(ACI Sec. 11.7.4)

Mu
'
0.383b d 2 f c
= 0.449 in

M u = V ua + N uc ( h d )

480

in-k

(ACI Sec. 10.2)

A s = MAX A f + A n ,

2 Avf
0.04 f c'
bd
+ An ,
3
fy

1.718

in

(ACI Sec. 11.9.3.5 & 11.9.5)

Ah =

A s An
2

0.467

(ACI Sec. 11.9.4)

in

<

A h , provd =

[SATISFACTORY]

0.660

in

__
Page 161 of 533
524

<

A s , provd =

1.800

[SATISFACTORY]

in2

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Development of Reinforcement Based on ACI 318-08


NON-SEISMIC TENSION DEVELOPMENTS

L dh = MAX

requird 0.02 ed b f
provided
f 'c

, 8d b , 6 in =

15 db

12

in, (ACI 318-08 12.5.2)

, 12 in =

26 db

20

in, (ACI 318-08 12.2.3)

requird 0.075 t e sd b f
provided
f c' c + K tr

L d = MAX

db

L hk

where

12

Bar size
db

in, (ACI 318-08, Fig. R12.5)


#

0.75

provided

fy

60

ksi

f'c

1.0

(1.3 for horizontal bar over 12" concrete, ACI 318-08 12.2.4)

1.0

(1.2 for epoxy-coated, ACI 318-08 12.2.4)

=
=
=

required

c
Ktr

(c + Ktr ) / db =

in
( A s,reqd / A s,provd , ACI 318-08, 12.2.5)

ksi

0.8
(0.8 for # 6 or smaller, 1.0 for other)
1.0
(0.75 for light weight, ACI 318-08, 12.2.4)
3.4
in, min(d' , 0.5s), (ACI 318-08, 12.2.4)
(Atr fyt / 1500 s n) =
0
(ACI 318-08, 12.2.3)
2.5
0.7

< 2.5 , (ACI 318-08, 12.2.3)


(#11 or smaller, cover > 2.5" & side >2.0", ACI 318-08 12.5.3)

SEISMIC TENSION DEVELOPMENTS

L dh = MAX

db f

65 f 'c

e , 8d b , 6 in =

13

in

where

Bar size

(ACI 318-08 21.5.4.1)

Ld = MAX ( 3.5L dh e , 12 in ) =
L hk

17 db

12

59 db

44

in, (ACI 318-08 21.5.4.2)

db

0.75

in

fy

60

ksi

f'c

ksi

e
=
1.0
(1.2 for epoxy-coated, ACI 318-08 21.5.4.4 & 12.2.4)

in, (ACI 318-08, Fig. R12.5)

NON-SEISMIC COMPRESSION DEVELOPMENT

L dc = MAX

requird 0.02d b f
'
provided
fc

requird
0.3d b f
provided

__
where

Bar size

db

0.75

provided

0.95

fy

60

ksi

f'c

1.0

Page 162 of 533


524

, 8 in =

21 db

16

in

(ACI 318-08 12.3)

required

in
(ACI 318-08 12.3.3 a)

ksi
(for spiral, 0.75, ACI 318-08 12.3.3 b)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Splice of Reinforcement Based on ACI 318-08


NON-SEISMIC TENSION SPLICE
ACI 318-08 Tab. R12.15.2
50% , Staggered
100% Lap
Class A
Class B
Class B
Class B

As,provd / As,reqd
2
<2

Ls

30 db

= 1.3 L d =

= 18

in

(for Class A, 1.0 L d , ACI 318-08, 12.15.1)

L d = MAX

0.075 t e sd b f

f c' c + K tr

, 12 in =

23 db

14
in
(ACI 318-08 12.15.1 & 12.2.3)

db

where

Bar size
db

5
0.625

in

fy

60

ksi

f'c

ksi

1.0

(1.3 for horizontal bar over 12" concrete, ACI 318-08 12.2.4)

1.0

(1.2 for epoxy-coated, ACI 318-08 12.2.4)

c
Ktr

=
=
=
=

0.8
(0.8 for # 6 or smaller, 1.0 for other)
1.0
(0.75 for light weight, ACI 318-08, 12.2.4)
1.7
in, min(d' , 0.5s), s = see fig above, (ACI 318-08, 12.2.4)
(Atr fyt / 1500 s n) =
0
(ACI 318-08, 12.2.3)

(c + Ktr ) / db =

2.5

< 2.5 , (ACI 318-08, 12.2.3)

SEISMIC TENSION SPLICE


Ls

66 db

= 1.3 L d =

= 42

in

(for Class A, 1.0 L d , ACI 318-08, 12.15.1)


L dh = MAX

db f

65 f

'
c

e , 8d b , 6 in =

L d = MAX ( 3.5L dh e , 12 in ) =
where

15 db

51 db

Bar size
db

5
0.625

in

fy

60

ksi

f'c

ksi

32

9
in
(ACI 318-08 21.5.4.1)
in, (ACI 318-08 21.5.4.2)

e
=
1.0
(1.2 for epoxy-coated, ACI 318-08 21.5.4.4 & 12.2.4)
NON-SEISMIC COMPRESSION SPLICE

Ls =

MAX ( 0.0005d b f

, 12 in

, for f y 60 ksi

MAX ( 0.0009 d b f y 24 d b , 12 in ) , for f y > 60 ksi


where

Bar size

30 db

23

in, (ACI 318-08 12.16.1)

db

0.75

in

fy

60

ksi

f'c

ksi

1.0

__
Page 163 of 533
524

(for fc' < 3 ksi, 4/3, ACI 318-08 12.16.1)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Tables for Development & Splice of Reinforcement Based on ACI 318-08


NON-SEISMIC TENSION DEVELOPMENTS
(FOR ALL DEVELOPMENTS EXCEPT LATERAL MOMENT FRAME, BEARING WALL & GRAVITY COLUMN)

Table 1: Ld Values (inch)


Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

2000
12
20
30
40
65
80
97
117
137
181
273

3000
12
16
24
33
53
66
80
96
112
148
223

4000
12
14
21
28
46
57
69
83
97
128
193

5000
12
13
19
25
41
51
62
74
87
114
173

fc' (psi)
6000
12
12
17
23
37
46
56
68
79
104
158

7000
12
12
16
22
35

8000
12
12
15
20
32

90
136

9000
12
12
14
19
31
38
46
55
65
85
129

10000
12
12
13
18
29
36
44
52
61
81
122

97
146

7000
6
6
6
8
9
10
11
13
14
17
23

8000
6
6
6
7
8
9
11
12
13
16
21

9000
6
6
6
7
8
9
10
11
12
15
20

10000
6
6
6
6
7
8
9
11
12
14
19

Table 2: Ldh Values (inch)


Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18
Note:

2000
7
9
12
14
16
19
21
24
26
32
42

3000
6
8
10
12
13
15
17
19
22
26
35

4000
6
7
8
10
12
13
15
17
19
22
30

5000
6
6
7
9
10
12
13
15
17
20
27

fc' (psi)
6000
6
6
7
8
9
11
12
14
15
18
24

Where horizontal bar is pleased such that more than 12 in of fresh concrete is cast below
the table values above must be increased 30%.

SEISMIC TENSION DEVELOPMENTS


(FOR LATERAL MOMENT FRAME ONLY)

Table 3: Ld Values (inch)


Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

2000
27
36
45
54
63
72
81
92
102
122
163

3000
22
29
37
44
52
59
67
75
83
100
133

4000
21
26
32
38
45
51
58
65
72
86
115

5000
21
23
29
34
40
46
52
58
64
77
103

fc' (psi)
6000
21
21
26
31
36
42
47
53
59
71
94

7000
21
21
24
29
34
39
44
49
54
65
87

8000
21
21
23
27
32
36
41
46
51
61
82

9000
21
21
21
26
30
34
38
43
48
58
77

10000
21
21
21
24
28
32
36
41
46
55
73

8000
6
6
6
8
9
10
12
13
15
17
23

9000
6
6
6
7
9
10
11
12
14
16
22

10000
6
6
6
7
8
9
10
12
13
16
21

Table 4: Ldh Values (inch)


Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

2000
8
10
13
15
18
21
23
26
29
35
47

3000
6
8
11
13
15
17
19
21
24
29
38

4000
6
7
9
11
13
15
16
19
21
25
33

5000
6
7
8
10
11
13
15
17
18
22
29

fc' (psi)
6000
6
6
7
9
10
12
13
15
17
20
27

7000
6
6
7
8
10
11
12
14
16
19
25

__
Page 164 of 533
524

(Cont'd)

NON-SEISMIC COMPRESSION DEVELOPMENT


(FOR BEARING WALL & GRAVITY COLUMN)

Table 5: Ldc Values (inch)


Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

2000
10
13
17
20
23
27
30
34
38
45
61

3000
8
11
14
16
19
22
25
28
31
37
49

4000
8
9
12
14
17
19
21
24
27
32
43

5000
8
9
11
14
16
18
20
23
25
30
41

fc' (psi)
6000
8
9
11
14
16
18
20
23
25
30
41

7000
8
9
11
14
16
18
20
23
25
30
41

8000
8
9
11
14
16
18
20
23
25
30
41

9000
8
9
11
14
16
18
20
23
25
30
41

10000
8
9
11
14
16
18
20
23
25
30
41

8000
12
12
12
12
19
22
26
31
35
44
62

9000
12
12
12
12
18
21
25
29
33
41
58

10000
12
12
12
12
17
20
23
27
31
39
55

NON-SEISMIC TENSION SPLICE


(FOR DOUBLE BARS USED WITH 50% STAGGERED IN CLASS B, TABLE 7)

Table 6: Ls Values (inch), CLASE A


Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

2000
12
16
20
24
37
45
52
61
70
88
124

3000
12
13
16
20
30
37
43
50
57
72
101

4000
12
12
14
17
26
32
37
43
49
62
88

5000
12
12
13
15
24
28
33
39
44
55
78

fc' (psi)
6000
12
12
12
14
22
26
30
35
40
51
72

7000
12
12
12
13
20
24
28
33
37
47
66

(FOR ALL SPLICE EXCEPT LATERAL FRAME, SHEAR WALL HORIZONTAL BARS & GRAVITY COLUMN)

Table 7: Ls Values (inch), CLASE B


Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18
Note:

2000
16
21
26
31
49
58
68
79
91
114
161

3000
16
17
21
26
40
47
56
65
74
93
132

4000
16
16
18
22
34
41
48
56
64
81
114

5000
16
16
17
20
31
37
43
50
57
72
102

fc' (psi)
6000
16
16
16
18
28
34
39
46
52
66
93

7000
16
16
16
17
26
31
36
42
49
61
86

8000
16
16
16
16
24
29
34
40
45
57
81

9000
16
16
16
16
23
27
32
37
43
54
76

10000
16
16
16
16
22
26
30
36
41
51
72

Where horizontal bar is pleased such that more than 12 in of fresh concrete is cast below
the table values above must be increased 30%.

SEISMIC TENSION SPLICE


(FOR DOUBLE BARS USED WITH 50% STAGGERED IN CLASS B, TABLE 9)

Table 8: Ls Values (inch), CLASE A


Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

2000
27
36
45
54
63
72
81
92
102
122
163

3000
22
29
37
44
52
59
67
75
83
100
133

4000
21
26
32
38
45
51
58
65
72
86
115

5000
21
23
29
34
40
46
52
58
64
77
103

fc' (psi)
6000
21
21
26
31
36
42
47
53
59
71
94

7000
21
21
24
29
34
39
44
49
54
65
87

8000
21
21
23
27
32
36
41
46
51
61
82

9000
21
21
21
26
30
34
38
43
48
58
77

10000
21
21
21
24
28
32
36
41
46
55
73

__
Page 165 of 533
524

(Cont'd)
(FOR LATERAL FRAME & SHEAR WALL HORIZONTAL BARS)

Table 9: Ls Values (inch), CLASE B


Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

2000
35
47
59
70
82
94
106
119
132
159
212

3000
29
38
48
58
67
77
86
97
108
130
173

4000
27
33
42
50
58
66
75
84
94
112
150

5000
27
30
37
45
52
59
67
75
84
101
134

fc' (psi)
6000
27
27
34
41
47
54
61
69
76
92
122

7000
27
27
31
38
44
50
57
64
71
85
113

8000
27
27
29
35
41
47
53
60
66
79
106

9000
27
27
28
33
39
44
50
56
62
75
100

10000
27
27
27
32
37
42
47
53
59
71
95

8000
12
15
19
23
26
30
34
38
42
51
68

9000
12
15
19
23
26
30
34
38
42
51
68

10000
12
15
19
23
26
30
34
38
42
51
68

NON-SEISMIC COMPRESSION SPLICE


(FOR GRAVITY COLUMN ONLY)

Table 10: Ls Values (inch)


Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

2000
16
20
25
30
35
40
45
51
56
68
90

3000
12
15
19
23
26
30
34
38
42
51
68

4000
12
15
19
23
26
30
34
38
42
51
68

5000
12
15
19
23
26
30
34
38
42
51
68

fc' (psi)
6000
12
15
19
23
26
30
34
38
42
51
68

7000
12
15
19
23
26
30
34
38
42
51
68

__
Page 166 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Shear Friction Reinforcing Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
FACTORED FRICTION FORCE
CONCRETE STRENGTH
REINFORCEMENT STRENGTH

FRICTION COEFFICIENT [See Table below]

=
=
=

500

kips

ksi

60

ksi

=
=
=

0.6

t
L

SHEAR PLANE THICKNESS


SHEAR PLANE LENGTH

DOWEL SIZE

Use

Vu
fc '
fy

Dowels

4.0

8
20
5

in
ft

in o.c.

ANALYSIS
CHECK SHEAR STRENGTH LIMITATION (Sec. 11.6.5)

Vn = MIN( 0.2fc' , 480 + 0.08fc' , 1600 ) Ac =

=
0.75 [Section 9.3.2.3]
2
Ac
=
1920 in

Where

1152

kips

>

Vu

[SATISFACTORY]

THE REQUIRED AREA OF SHEAR-TRANSFER REINFORCEMENT IS GIVEN BY SECTION 11.6.4.1 AS


2
Avf = Vu / (
fy ) =
18.5 in
COEFFICIENT OF FRICTION FOR NORMAL WEIGHT CONCRETE [Sec.11.6.4.3]
Concrete place monolithically
Concrete placed against hardened concrete with surface intentionally roughened
Concrete placed against hardened concrete NOT intentionally roughened
Concrete anchored to as-rolled structural steel by headed stud or by reinforcing bars

__
Page 167 of 533
524

1.40
1.00
0.60
0.70

<=

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Shear Friction Reinforcing Design Based on ACI 318-08


Ru

INPUT DATA & DESIGN SUMMARY

Ru
Tu
f c'
fy
a
b

=
=
=
=
=
=

- leg ties

FACTORED FRICTION FORCE VERTICAL


FACTORED FRICTION FORCE HORIZONTAL
CONCRTET STRENGTH
REINFORCEMENT STRENGTH
BEARING WIDTH
BEARING THICKNESS
REINFORCEMENT

ASSUME A POTENTIAL CRACK PLANE WITH AN ANGLE OF f =

86

kips

34

kips

ksi

60

ksi

5
18
3

in
in

70

degrees

5.0

in

Tu

14 in

Use
6
#
3
with (2) - leg closed ties
Distribute over a vert. distance of 14 in
ANALYSIS

FRICTION COEFFICIENT [Sec.11.6.4.3]

FORCES ON INCLINED PLANE:


Vu
= Ru sin f + Tu cos f = 92.4 kips
Where

Ac

Nu

=
=

0.75
268

1.4

<

Vn = MIN( 0.2fc' , 480+0.08fc' , 1600 ) Ac =

[Section 9.3.2.3]
2
in

Tu sin f - Ru cos f

[SATISFACTORY]
2.5 kips

( net tension )

SHEAR FRICTION REINFORCEMENT IS GIVEN BY EQ(11-26) AS


2
Avf =Vu / [ fy ( sin f + cos f )]
=
1.24 in
REINFORCEMENT TO RESIST TENSION IS GIVEN BY SEC. 11.6.7 AS
2
An = Nu / ( fy sin f)
=
0.06 in
TOTAL REINFORCEMENT:

As = Avf + An =

1.30 in

__
Page 168 of 533
524

160.6 kips
(Sec. 11.6.5)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Design of Post-Tensioned Concrete Floor Based on ACI 318-08


1. DESIGN METHODS
1.1 BREAKDOWN TWO WAYS FLOOR INTO DESIGN STRIPS IN ONE DIRECTION AND ONE WAY SLABS IN OTHER
DIRECTION. DESIGN STRIPS WORK AS CONTINUOUS BEAMS BY BANDED ALL TENDONS AT COLUMN. THE
PERPENDICULAR DIRECTION LIKE MULTI-SPAN ONE WAY SLABS, USING DISTRIBUTED TENDONS.
1.2 SPECIFY TOTAL REQUIRED EFFECTIVE POST-TENSIONING FORCES AT BANDED TENDONS, ON STRUCTURAL DRAWINGS,
AND UNIFORM FORCES IN DISTRIBUTED TENDONS.
1.3 WHEN TENDON LESS THAN 140 FT, STRESS AT ONE END. OTHERWISE STRESS AT BOTH ENDS.
1.4 THE VARIOUS LIVE LOADING CONDITIONS SHOULD BE CONSIDER BY INPUT LL ZERO AT SOME SPANS.

2. INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

f'c

REBAR YIELD STRESS

fy

TENDON PROPERTIES

fpu

=
=
=
=
=
=
=
=
=
=
=
#
#

fpy
fse
dia
Aps
SLAB THICKNESS

TRIBUTARY WIDTH IF BANDED AS DESIGN STRIPS

COLUMN WIDTH

c1

COLUMN DEPTH

c2

TOP BAR SIZE AT COLUMN


BOTTOM CONTINUOUS BAR SIZE

Location

Mid of L1

Left

4.5

ksi

270

ksi

243

ksi

175

ksi

1/2
0.153

in
in2

in

30

ft

22

in

CONCRETE COST =

THE DESIGN IS ADEQUATE.

22

in

TENDONS COST =

0.476

lb / ft2

REBARS COST =

0.349

lb / ft2

lb / ft2

100

Mid of L2

Support

ksi

60

Support

Mid of LTyp

Support

Mid of Ln-1

Support

Mid Ln

Span (ft)

20

30

30

30

20

DL (psf)

120

120

120

120

120

LL (psf)

75

75

75

75

75

75%

75%

80%

75%

75%

Balanced DL (60%-80% suggested)


dCGS (in, from bottom)

3.33

REQD EFFECTIVE PT (k / ft)


Total if banded (kips)
Tendons

2.5

2.5

7.5

2.5

25.92

7.5

3.33

24.30

22.31

669.4

729.0

777.6

729.0

669.4

1 / 2 in Dia @ 13 in o.c.

1 / 2 in Dia @ 12 in o.c.

1 / 2 in Dia @ 13 in o.c.

1 / 2 in Dia @ 14 in o.c.

26

28

30

28

26

7 # 5 , L = 3.03 ft

Bot Bars, Cont., E. Way

10 # 5 , L = 9.39 ft
Not ReqD

Required column cap thk, (in)

7.5

24.30

1 / 2 in Dia @ 14 in o.c.

Total Number if banded


Top Bars at Column

7.5

22.31

Right

Not ReqD

22 # 5 , L = 9.39 ft

22 # 5 , L = 9.39 ft

# 4 @ 45in. o.c.
Not ReqD

Not ReqD
Not ReqD

10 # 5 , L = 9.39 ft

# 4 @ 45in. o.c.
Not ReqD

7 # 5 , L = 3.03 ft
Not ReqD

Not ReqD

Not ReqD

3. DESIGN LOADS & SECTION FORCES


Location

Left

Mid of L1

Support

Mid of L2

Support

Mid of LTyp

Support

Mid of Ln-1

Support

Mid Ln

MDL (ft-k / ft)

0.00

2.14

-7.72

5.01

-9.26

4.24

-9.26

5.01

-7.72

2.14

0.00

MLL (ft-k / ft)

0.00

1.34

-4.83

3.13

-5.78

2.65

-5.78

3.13

-4.83

1.34

0.00

0.00

-1.65

5.71

-3.66

7.23

-3.57

7.23

-3.66

5.71

-1.65

Balanced Load (psf, uplift)

-90

Balanced MBal (ft-k / ft)


Required Effective PT (k / ft)
Tendon Spacing (in)
Primary MFe (ft-k / ft)

0.00

-90

0.00

-90

-90

22.31

24.30

25.92

24.30

14

13

12

13

-1.25

6.51
7.09

Secondary MSec (ft-k / ft)

-96

0.40

7.56
-3.04

7.09

1.38

0.62

-0.14

0.80

-3.24

0.33

0.33

0.00

22.31
14

7.56
7.09

Right

6.51
-3.04

7.09

-0.14

0.62

1.38

0.33

0.80

-1.25

0.00

0.40

0.00

Right

4. CHECK SERVICE LOAD STRESSES


Location

Left

Mid of L1

Support

Mid of L2

Support

Mid of LTyp

Support

Mid of Ln-1

Support

Mid Ln

A (in2 / ft)

96

96

96

96

96

96

96

96

96

96

96

S (in3 / ft)

128

128

128

128

128

128

128

128

128

128

128

F / A (ksi)

0.232

0.232

0.270

0.270

0.232

0.232

0.232

0.253

0.253

0.253

0.253

0.279

0.232

0.380

0.064
0.186

0.232

0.126

0.442
0.503

0.45 fc' =

2.025

-0.409

0.404

0.232

0.061

0.232

0.6 fc' =

2.700

0.232
0.253

Check 125 psi < F /A < 275 psi


M / S + F / A , (ksi)

0.232

[Satisfactory]
0.279

for load combination (DL + PT)

- M / S + F / A , (ksi)

0.232

0.186

Check ft < 7.5 (fc')


M / S + F / A , (ksi)

and fc < 0.45 fc'


0.232

0.404

0.232

Check ft < 7.5 (fc')

0.061

and fc < 0.6 fc'

__
0.443

0.460

[Satisfactory]

0.333

-0.462

0.674

-0.479

-0.167

0.985

1.002

0.207

0.582

where

0.421
7.5 (fc')

0.5

-0.462

-0.479

-0.042

0.043

0.460

0.443

(ACI 318-08, 18.3.3 & 18.4.2b),

Page 169 of 533


524

0.080

0.063

(ACI 318-08, 18.3.3 & 18.4.2a),

0.874

0.895

0.5

0.126

-0.409

-0.388

- M / S + F / A , (ksi)

0.063

[Satisfactory]

for load (DL + LL + PT)


for load (DL + LL + PT)

0.080

0.380

0.421

0.442

0.5

(ADAPT suggestion)

0.043

0.064

for load combination (DL + PT)

0.270
0.253

0.674

-0.388

-0.167

0.895

1.002

0.985

where

0.874
7.5 (fc')

0.5

0.503

(cont'd)

5. CALCULATE NON-PRESTRESSED REINFORCEMENT


Location

Left

Max. Nc (k / ft), (ACI 318, 18.0)

Mid of L1

Support

Mid of L2

0.000

As (in2 / ft), (ACI 318, 18.9.3.2)


Bottom Bars, Each Way

Support

Mid of LTyp

1.599

Support

Mid of Ln-1

0.134

Support

1.599

Mid Ln

Right

0.000

0.000

0.053

0.000

0.053

0.000

Not ReqD

# 4 @ 45in. o.c.

Not ReqD

# 4 @ 45in. o.c.

Not ReqD

Max. Acf (in2), (ACI 318, 18.0)

2880

2880

2880

2880

2880

2880

As' (in2), (ACI 318, 18.9.3.2)

2.160

2.160

2.160

2.160

2.160

2.160

7#5

7#5

7#5

7#5

7#5

7#5

3.03

9.39

9.39

9.39

9.39

3.03

Top Bars at Column


L (ft), (ACI 318, 18.9.4.1)

6. CHECK FLEXURAL CAPACITY BY STRENGTH DESIGN METHOD


Location
Factored Mu (ft-k / ft)

Left

Mid of L1

Support

0.00

5.11

-16.19

1.2 MDL + 1.6 MLL + 1.0 MSec


dp (in)

Mid of L2

-15.61

11.64
5.50

Support

Mid of LTyp

Support

-20.03

9.67

-20.03

-20.50

Mid of Ln-1

-20.50

11.64
5.50

4.00

4.67

7.50

0.00273

0.00234

0.00146
0.00157

0.00214

0.00157

0.00157

0.00214

L / dp

60.00

51.39

40.00

65.45

48.00

65.45

48.00

65.45

fps (ksi)

185.64

186.56

190.44

188.24

185.88

188.24

0.131

0.131

(ACI 318, 18.7.2, b & c)

191.62

Aps (in2 / ft)


Actual Area
d (in)

6.63

6.75

a (in)

0.21

0.40

203.09

Actual As (in2 / ft)

0.14

Top Bars at Column

6.63

6.75

6.63

6.75

0.85

0.55

0.88

Right

5.11

0.00

-15.61
7.50

4.67

4.00

0.00146

0.00234

0.00273

0.00157

203.09

40.00

51.39

60.00

190.44

186.56

185.64

0.131

0.131

191.62

0.153

0.131

0.141

0.65

Mid Ln

-16.19

0.14

6.63

0.14

6.75

6.63

6.75

6.63

0.67

0.40

0.21

0.65

0.64

0.85
0.88

0.000

0.018

0.000

0.018

0.000

Not ReqD

# 4 @ 136in. o.c.

Not ReqD

# 4 @ 136in. o.c.

Not ReqD

0.053

0.000

0.053

0.000

0.000

2.933

6.655

6.655

2.933

0.000

Not ReqD

10 # 5

22 # 5

22 # 5

10 # 5

Not ReqD

Actual As' (in )

2.170

Mn (ft-k / ft)

-9.23

8.21

Actual Capacity

3.100

6.820

-16.34

-21.62

-17.51

Check Mn > Mu
pt, (ACI 318, 18.8.1)

191.62
0.153

0.14

0.67

0.000

Required As' (in2)

7.50
0.00170

0.153

0.64
Required As (in2 / ft)

5.50
0.00232

191.62

0.131
0.141

Bottom Bars, Each Way

7.50
0.00170

Support

12.68

11.14

-20.66

6.820

3.100

-21.62

-16.34

-20.66

12.68

2.170
8.21

-9.23

0.0262

0.0433

-17.51

[Satisfactory]
0.0433

0.0262

c(dp - a / 1) / (a / 1)

0.0246

0.0188

0.0261

Check pt > 0.005

0.0180

[Satisfactory]

0.0216

0.0181

0.0188

0.0246

0.0181

0.0180

0.0261

Support

Mid of Ln-1

Support

(ACI 318, 18.8.1)

7. CHECK PUNCHING SHEAR CAPACITY BY STRENGTH DESIGN METHOD


Location

Left

RDL (k)

Mid of L1

35.99

Support

Mid of L2

90.01

Support

Mid of LTyp

108.00

108.00

Mid Ln

90.01

Right
35.99

RLL (k)

22.49

56.26

67.50

67.50

56.26

22.49

RSec (k)

-26.99

-67.51

-83.70

-83.70

-67.51

-26.99

52.18

130.52

153.90

153.90

130.52

52.18

Vu =1.2 RDL + 1.6 RLL + 1.0 Rsec

228.48

565.70

655.06

655.06

565.70

228.48

Required d, (ACI 318, 11.0)

Required b0d, (ACI 318, 11-36)

3.16

5.20

5.88

5.88

5.20

3.16

For Vn < Vu, the required

0.00

0.00

0.00

0.00

0.00

0.00

Not ReqD

Not ReqD

Not ReqD

Not ReqD

Not ReqD

Not ReqD

column cap thickness, tcap (in)

8. CALCULATE COST FOR SLAB & CAP


Location
Concrete

Left

Mid of L1

Mid of L2

Support

Mid of LTyp

Support

1.67

5.00

5.00

5.00

cap concrete

0.00

0.00

0.00

0.00

Total =
length (ft)

Tendons

Support

cap dim (ft)

44.71

Rebars

179395

20.01

T / 30 ft TW

Average =

30.02

Total =

854.2

0.00

198.08

Total =

625.5

T / 30 ft TW
10.89

Mid of Ln-1

30.02
, (ACI 318 App. E)
435.77

0.00

T / 30 ft TW

100
30.02

Average =

0.476

435.77

10.89

Average =

0.349

Support

Mid Ln

Right

5.00

1.67

0.00

0.00

lb / ft

20.01
lb / ft2 , (AISC Manual 2nd page 7-15)
198.08
lb / ft2

0.00

44.71

Note:
1. The column moments are negligible for gravity punching design. Lateral loads, seismic and wind, should be supported by shear walls. Using equivalent frames to support lateral loads is not suggested.
2. By inspection, the deflections of slab do not govern PT concrete floor design. Otherwise, using PT concrete floor is inadequate for larger live load. (ACI 318, 9.5.4.1)
3. The secondary moments are very important concept of PT floor design. Based on this concept, PT floor design are always continuous beams design and one way slabs design. So using two
ways finite element analysis to design PT floor is inadequate.
Technical References:
1. "Design of Post-Tensioned Slabs Using Unbounded Tendons, Third Edition", The Post-Tensioning Institute, 2004.
2. "Design, Construction and Maintenance of Cast-in-Place Post-Tensioned Concrete Parking Structures, First Edition", The Post-Tensioning Institute, 2001.
3. Bijan O. Aalami & Allan Bommer, "Design Fundamentals of Post-Tensioned Concrete Floors, First Edition", The Post-Tensioning Institute, 1999.

__
Page 170 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Design of Post-Tensioned Concrete Floor Based on ACI 318-08


1. DESIGN METHODS
1.1 BREAKDOWN TWO WAYS FLOOR INTO DESIGN STRIPS IN ONE DIRECTION AND ONE WAY SLABS IN OTHER
DIRECTION. DESIGN STRIPS WORK AS CONTINUOUS BEAMS BY BANDED ALL TENDONS AT COLUMN. THE
PERPENDICULAR DIRECTION LIKE MULTI-SPAN ONE WAY SLABS, USING DISTRIBUTED TENDONS.
1.2 SPECIFY TOTAL REQUIRED EFFECTIVE POST-TENSIONING FORCES AT BANDED TENDONS, ON STRUCTURAL DRAWINGS,
AND UNIFORM FORCES IN DISTRIBUTED TENDONS.
1.3 WHEN TENDON LESS THAN 140 FT, STRESS AT ONE END. OTHERWISE STRESS AT BOTH ENDS.
1.4 THE VARIOUS LIVE LOADING CONDITIONS SHOULD BE CONSIDER BY INPUT LL ZERO AT SOME SPANS.

2. INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

f'c

REBAR YIELD STRESS

fy

TENDON PROPERTIES

fpu
fpy
fse
dia
Aps

SLAB THICKNESS

TRIBUTARY WIDTH IF BANDED AS DESIGN STRIPS

COLUMN WIDTH

c1

COLUMN DEPTH

c2

TOP BAR SIZE AT COLUMN


BOTTOM CONTINUOUS BAR SIZE

Location

Mid of L1

Left

Support

=
=
=
=
=
=
=
=
=
=
=
#
#

Mid of L2

ksi

60

ksi

270

ksi

243

ksi

175

ksi

1/2
0.153

in
in2

in

30

ft

22

in

CONCRETE COST =

THE DESIGN IS ADEQUATE.

22

in

TENDONS COST =

0.484

lb / ft2

REBARS COST =

0.289

lb / ft2

Support

Mid of L3

Support

Mid L4

20

30

30

20

DL (psf)

120

120

120

120

LL (psf)

75

75

75

75

75%

80%

80%

75%

dCGS (in, from bottom)

3.33

REQD EFFECTIVE PT (k / ft)


Total if banded (kips)
Tendons

2.5

2.5

7.5

3.33

25.92

22.31

669.4

777.6

777.6

669.4

1 / 2 in Dia @ 12 in o.c.

1 / 2 in Dia @ 12 in o.c.

1 / 2 in Dia @ 14 in o.c.

26

30

30

26

7 # 5 , L = 3.03 ft

Bot Bars, Cont., E. Way


Required column cap thk, (in)

7.5

25.92

Right

1 / 2 in Dia @ 14 in o.c.

Total Number if banded


Top Bars at Column

7.5

22.31

9 # 5 , L = 9.39 ft
Not ReqD

Not ReqD

22 # 5 , L = 9.39 ft
Not ReqD

Not ReqD

lb / ft2

Span (ft)

Balanced DL (60%-80% suggested)

100

9 # 5 , L = 9.39 ft

# 4 @ 378in. o.c.
Not ReqD

7 # 5 , L = 3.03 ft
Not ReqD

Not ReqD

Not ReqD

3. DESIGN LOADS & SECTION FORCES


Location

Left

Mid of L1

Support

Mid of L2

Support

Mid of L3

Support

Mid L4

MDL (ft-k / ft)

0.00

2.21

-7.59

4.85

-9.71

4.85

-7.59

2.21

0.00

MLL (ft-k / ft)

0.00

1.38

-4.74

3.03

-6.07

3.03

-4.74

1.38

0.00

0.00

-1.54

5.93

-3.92

7.84

-3.92

5.93

-1.54

Balanced Load (psf, uplift)


Balanced MBal (ft-k / ft)

-90

Required Effective PT (k / ft)


Tendon Spacing (in)

-96

-96

22.31

25.92

25.92

14

12

12

Primary MFe (ft-k / ft)

0.00

-1.25

Secondary MSec (ft-k / ft)

0.00

0.29

6.51
7.56

7.56
-3.24

0.58

-3.24

7.56
-0.28

1.63

0.68

-0.28

-90
0.00

22.31
14
7.56
6.51

0.68

Right

-1.25

0.00

0.58

0.29

0.00

Right

1.63

4. CHECK SERVICE LOAD STRESSES


Location

Left

Mid of L1

Support

Mid of L2

Support

Mid of L3

Support

Mid L4

A (in2 / ft)

96

96

96

96

96

96

96

96

96

S (in3 / ft)

128

128

128

128

128

128

128

128

128

F / A (ksi)

0.232

0.232

0.232

0.270

0.270

0.270

0.270

0.270

0.232

0.232

0.295

0.232

0.388

0.170

0.232

where

0.45 fc' =

0.530

0.425

0.232

0.833

0.040

0.232

where

7.5 (fc')0.5 =

0.530

0.270
Check 125 psi < F /A < 275 psi
M / S + F / A , (ksi)

0.232

[Satisfactory]
0.295

for load combination (DL + PT)

- M / S + F / A , (ksi)

0.170

for load combination (DL + PT)

0.232

0.425

for load (DL + LL + PT)


Check ft < 7.5 (fc')0.5 and fc < 0.6 fc'

0.040

__
0.833

0.870

[Satisfactory]

0.182

0.445

-0.474

0.642

-0.102

0.642

-0.474
1.014

0.426

-0.102

1.014

0.45 fc' =

2.250

0.6 fc' =

3.000

-0.330

-0.368

(ACI 318-08, 18.3.3 & 18.4.2b),

Page 171 of 533


524

0.114

0.077

(ACI 318-08, 18.3.3 & 18.4.2a),

-0.368
-0.330

0.232

0.182

0.358

0.095

0.445

[Satisfactory]

for load (DL + LL + PT)

- M / S + F / A , (ksi)

0.095

0.358

0.388
0.426

Check ft < 7.5 (fc')0.5 and fc < 0.45 fc'


M / S + F / A , (ksi)

0.077

0.114

0.232

0.232

(ADAPT suggestion)

0.870

(cont'd)

5. CALCULATE NON-PRESTRESSED REINFORCEMENT


Location

Left

Max. Nc (k / ft), (ACI 318, 18.0)

Mid of L1

Support

Mid of L2

0.000

As (in2 / ft), (ACI 318, 18.9.3.2)


Bottom Bars, Each Way

Support

Mid of L3

0.672

Support

Mid L4

0.672

Right

0.000

0.000

0.000

0.000

0.000

Not ReqD

Not ReqD

Not ReqD

Not ReqD

Max. Acf (in2), (ACI 318, 18.0)

2880

2880

2880

2880

2880

As' (in2), (ACI 318, 18.9.3.2)

2.160

2.160

2.160

2.160

2.160

7#5

7#5

7#5

7#5

7#5

3.03

9.39

9.39

9.39

3.03

Top Bars at Column


L (ft), (ACI 318, 18.9.4.1)

6. CHECK FLEXURAL CAPACITY BY STRENGTH DESIGN METHOD


Location
Factored Mu (ft-k / ft)

Left

Mid of L1

Support

0.00

5.14

-16.12

1.2 MDL + 1.6 MLL + 1.0 MSec


dp (in)

Mid of L2

-15.06

11.35
5.50

Support

Mid of L3

Support

Mid L4

Right

-21.63

11.35

-15.06

5.14

0.00

4.67

4.00

-21.63

-16.12

4.00

4.67

7.50

0.00273

0.00234

0.00146
0.00170

0.00232

0.00170

0.00146

0.00234

0.00273

L / dp

60.00

51.39

40.00

65.45

48.00

65.45

40.00

51.39

60.00

fps (ksi)

186.25

187.27

191.59

189.22

186.60

189.22
187.27

186.25

0.131

0.131

0.131

(ACI 318, 18.7.2, b & c)

189.22

Aps (in2 / ft)

200.98

0.131

Actual Area
d (in)

0.153

0.15

6.63

6.75

6.63

6.75

0.19

0.36

0.60
0.54

Required As (in2 / ft)


Actual As (in2 / ft)
Top Bars at Column

7.50
0.00170

189.22

191.59
0.153

0.15

0.153
0.131

0.131

6.63

6.75

6.63

6.75

6.63

0.83

0.57

0.54
0.36

0.19

0.83

0.60

0.000

0.000

0.006

0.000

Not ReqD

Not ReqD

# 4 @ 378in. o.c.

Not ReqD

0.000

0.006

0.000

0.000

2.683

6.705

2.683

0.000

Not ReqD

9#5

22 # 5

9#5

Not ReqD

2.790

2.170

Actual As' (in )

2.170

Mn (ft-k / ft)

-9.28

8.27

Actual Capacity

2.790

6.820

-16.22

-21.74

-18.36

Check Mn > Mu
pt, (ACI 318, 18.8.1)

0.58

0.000

Required As' (in2)

5.50
0.00232

0.153

a (in)

Bottom Bars, Each Way

7.50
0.00170

12.02

11.35

-21.74

-18.36
-16.22

8.27

-9.28

0.0271

0.0284

0.0469

Support

Mid L4

[Satisfactory]
0.0469

0.0284

c(dp - a / 1) / (a / 1)

0.0271

0.0187

0.0302

Check pt > 0.005

0.0199

[Satisfactory]

0.0203

0.0187

0.0302

(ACI 318, 18.8.1)

7. CHECK PUNCHING SHEAR CAPACITY BY STRENGTH DESIGN METHOD


Location

Left

RDL (k)

Mid of L1

35.99

Support

Mid of L2

90.01

Support

Mid of L3

108.00

90.01

Right
35.99

RLL (k)

22.49

56.26

67.50

56.26

22.49

RSec (k)

-26.99

-70.21

-86.40

-70.21

-26.99

52.18

127.81

151.21

127.81

52.18

Vu =1.2 RDL + 1.6 RLL + 1.0 Rsec

219.34

527.85

613.74

527.85

219.34

Required d, (ACI 318, 11.0)

Required b0d, (ACI 318, 11-36)

3.04

4.90

5.57

4.90

3.04

For Vn < Vu, the required

0.00

0.00

0.00

0.00

0.00

Not ReqD

Not ReqD

Not ReqD

Not ReqD

Not ReqD

column cap thickness, tcap (in)

8. CALCULATE COST FOR SLAB & CAP


Location
Concrete

Left

Mid of L1

Mid of L2

Support

Mid of LTyp

Support

1.67

5.00

5.00

5.00

cap concrete

0.00

0.00

0.00

0.00

Total =
length (ft)

Tendons

Support

cap dim (ft)

44.71

Rebars

138572

20.01

T / 30 ft TW

Average =

30.02

Total =

670.1

0.00

178.27

Total =

400.5

T / 30 ft TW
0.00

Mid of Ln-1

30.02
, (ACI 318 App. E)
435.77

1.30

T / 30 ft TW

Right
5.00
0.00

100

lb / ft

20.01
Average =

0.484

lb / ft2 , (AISC Manual 2nd page 7-15)

178.27

0.00

Average =

0.289

44.71
lb / ft2

Note:
1. The column moments are negligible for gravity punching design. Lateral loads, seismic and wind, should be supported by shear walls. Using equivalent frames to support lateral loads is not suggested.
2. By inspection, the deflections of slab do not govern PT concrete floor design. Otherwise, using PT concrete floor is inadequate for larger live load. (ACI 318, 9.5.4.1)
3. The secondary moments are very important concept of PT floor design. Based on this concept, PT floor design are always continuous beams design and one way slabs design. So using two
ways finite element analysis to design PT floor is inadequate.
Technical References:
1. "Design of Post-Tensioned Slabs Using Unbounded Tendons, Third Edition", The Post-Tensioning Institute, 2004.
2. "Design, Construction and Maintenance of Cast-in-Place Post-Tensioned Concrete Parking Structures, First Edition", The Post-Tensioning Institute, 2001.
3. Bijan O. Aalami & Allan Bommer, "Design Fundamentals of Post-Tensioned Concrete Floors, First Edition", The Post-Tensioning Institute, 1999.

__
Page 172 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Design of Post-Tensioned Concrete Floor Based on ACI 318-08


1. DESIGN METHODS
1.1 BREAKDOWN TWO WAYS FLOOR INTO DESIGN STRIPS IN ONE DIRECTION AND ONE WAY SLABS IN OTHER
DIRECTION. DESIGN STRIPS WORK AS CONTINUOUS BEAMS BY BANDED ALL TENDONS AT COLUMN. THE
PERPENDICULAR DIRECTION LIKE MULTI-SPAN ONE WAY SLABS, USING DISTRIBUTED TENDONS.
1.2 SPECIFY TOTAL REQUIRED EFFECTIVE POST-TENSIONING FORCES AT BANDED TENDONS, ON STRUCTURAL DRAWINGS,
AND UNIFORM FORCES IN DISTRIBUTED TENDONS.
1.3 WHEN TENDON LESS THAN 140 FT, STRESS AT ONE END. OTHERWISE STRESS AT BOTH ENDS.
1.4 THE VARIOUS LIVE LOADING CONDITIONS SHOULD BE CONSIDER BY INPUT LL ZERO AT SOME SPANS.

2. INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

f'c

REBAR YIELD STRESS

fy

TENDON PROPERTIES

fpu

=
=
=
=
=
=
=
=
=
=
=
#
#

fpy
fse
dia
Aps
SLAB THICKNESS

TRIBUTARY WIDTH IF BANDED AS DESIGN STRIPS

COLUMN WIDTH

c1

COLUMN DEPTH

c2

TOP BAR SIZE AT COLUMN


BOTTOM CONTINUOUS BAR SIZE

Location

Mid of L1

Left

ksi

270

ksi

243

ksi

175

ksi

1/2
0.153

in
in2

in

30

ft

22

in

CONCRETE COST =

THE DESIGN IS ADEQUATE.

22

in

TENDONS COST =

0.468

lb / ft2

REBARS COST =

0.321

lb / ft2

Support

Mid of L3

Span (ft)

20

30

20

DL (psf)

120

120

120

LL (psf)

75

75

75

75%

80%

75%

Balanced DL (60%-80% suggested)


dCGS (in, from bottom)

3.33

REQD EFFECTIVE PT (k / ft)


Total if banded (kips)
Tendons

2.5

3.33

22.31

777.6

669.4

1 / 2 in Dia @ 12 in o.c.

1 / 2 in Dia @ 14 in o.c.

26

30

26

Bot Bars, Cont., E. Way

15 # 5 , L = 9.39 ft
Not ReqD

Required column cap thk, (in)

7.5

25.92

669.4

7 # 5 , L = 3.03 ft
Not ReqD

15 # 5 , L = 9.39 ft

# 4 @ 58in. o.c.
Not ReqD

lb / ft2

Right

1 / 2 in Dia @ 14 in o.c.

Total Number if banded


Top Bars at Column

7.5

22.31

100

Mid of L2

Support

ksi

60

7 # 5 , L = 3.03 ft
Not ReqD

Not ReqD

Not ReqD

3. DESIGN LOADS & SECTION FORCES


Location

Left

Mid of L1

Support

Mid of L2

Support

Mid of L3

MDL (ft-k / ft)

0.00

1.96

-8.08

5.42

-8.08

1.96

0.00

MLL (ft-k / ft)

0.00

1.23

-5.05

3.39

-5.05

1.23

0.00

0.00

-1.32

6.37

-4.43

6.37

-1.32

Balanced Load (psf, uplift)

-90

Balanced MBal (ft-k / ft)


Required Effective PT (k / ft)
Tendon Spacing (in)
Primary MFe (ft-k / ft)

0.00

-96

22.31

25.92

14

12

-1.25

6.51
7.56

Secondary MSec (ft-k / ft)

0.00

0.07

-90
0.00

22.31
14
6.51

-3.24

7.56

1.19

1.19

1.19

0.14

Right

0.14

-1.25

0.00

0.07

0.00

Right

4. CHECK SERVICE LOAD STRESSES


Location

Left

Mid of L1

Support

Mid of L2

Support

Mid of L3

A (in2 / ft)

96

96

96

96

96

96

96

S (in3 / ft)

128

128

128

128

128

128

128

F / A (ksi)

0.232

0.232

0.232

0.232

0.232

0.232

0.270

0.270

0.270
Check 125 psi < F /A < 275 psi
M / S + F / A , (ksi)

0.232

[Satisfactory]
0.293

for load combination (DL + PT)

- M / S + F / A , (ksi)
Check ft < 7.5 (fc')

0.232

0.172

M / S + F / A , (ksi)

and fc < 0.45 fc'


0.232

0.408

- M / S + F / A , (ksi)

0.232

0.057

and fc < 0.6 fc'

0.172

0.232

0.430

-0.401

0.681

0.866

[Satisfactory]

0.232

(ACI 318-08, 18.3.3 & 18.4.2a),

-0.401

0.903

0.5

0.293

0.110

0.393

0.177

[Satisfactory]

-0.363

for load (DL + LL + PT)

0.072

0.363

0.393
0.430

0.5

for load (DL + LL + PT)

Check ft < 7.5 (fc')

__
0.110

for load combination (DL + PT)

(ADAPT suggestion)

0.072

0.408

0.232

0.057

0.232

0.45 fc' =

0.530

0.45 fc' =

2.250

7.5 (fc')0.5 =

0.530

0.6 fc' =

3.000

-0.363
0.866

-0.141

where

0.903

(ACI 318-08, 18.3.3 & 18.4.2b),

Page 173 of 533


524

where

(cont'd)

5. CALCULATE NON-PRESTRESSED REINFORCEMENT


Location

Left

Max. Nc (k / ft), (ACI 318, 18.0)

Mid of L1

Support

Mid of L2

0.000

As (in2 / ft), (ACI 318, 18.9.3.2)


Bottom Bars, Each Way

Support

Mid of L3

1.158

Right

0.000

0.000

0.000

0.000

Not ReqD

Not ReqD

Not ReqD

Max. Acf (in2), (ACI 318, 18.0)

2880

2880

2880

2880

As' (in2), (ACI 318, 18.9.3.2)

2.160

2.160

2.160

2.160

7#5

7#5

7#5

7#5

3.03

9.39

9.39

3.03

Top Bars at Column


L (ft), (ACI 318, 18.9.4.1)

6. CHECK FLEXURAL CAPACITY BY STRENGTH DESIGN METHOD


Location
Factored Mu (ft-k / ft)

Left

Mid of L1

Support

0.00

4.39

-17.63

1.2 MDL + 1.6 MLL + 1.0 MSec


dp (in)

Mid of L2

-16.58

13.12
5.50

4.00

4.67

7.50

0.00273

0.00234

0.00146
0.00170

0.00232

L / dp

60.00

51.39

40.00

65.45

fps (ksi)

186.25

187.27

191.59

0.131

0.131

(ACI 318, 18.7.2, b & c)

189.22

Aps (in2 / ft)


Actual Area
d (in)

6.63

6.75

a (in)

0.19

0.33

Actual As (in2 / ft)


Top Bars at Column

7.50

4.67

4.00

0.00146

0.00234

0.00273

40.00

51.39

60.00

191.59

187.27

186.25

0.131

0.131

0.131

6.63

0.15

6.75

6.63

6.75

6.63

0.66

0.33

0.19

0.65

0.61

0.66

0.000

0.041

0.000

Not ReqD

# 4 @ 58in. o.c.

Not ReqD

0.041

0.000

0.000

4.367

4.367

0.000

Not ReqD

15 # 5

15 # 5

Not ReqD

Actual As' (in )

2.170

Mn (ft-k / ft)

-9.28

8.30

Actual Capacity

4.650

4.650

-17.90

-17.90

-20.03

Check Mn > Mu
pt, (ACI 318, 18.8.1)

0.00

189.22

0.15

0.000

Required As' (in2)

Right

4.39

0.00170

200.98

0.61
Required As (in2 / ft)

Mid of L3

-17.63
-16.58

0.131
0.153

Bottom Bars, Each Way

Support

13.13

2.170
8.30

-9.28

0.0314

0.0469

-20.03

[Satisfactory]
0.0469

0.0314

c(dp - a / 1) / (a / 1)

0.0241

0.0241

0.0267

Check pt > 0.005

0.0173

[Satisfactory]

0.0267
(ACI 318, 18.8.1)

7. CHECK PUNCHING SHEAR CAPACITY BY STRENGTH DESIGN METHOD


Location

Left

RDL (k)

Mid of L1

35.99

Support

Mid of L2

90.01

Support

Mid of L3

90.01

Right
35.99

RLL (k)

22.49

56.26

56.26

22.49

RSec (k)

-26.99

-70.21

-70.21

-26.99

52.18

127.82

127.82

52.18

Vu =1.2 RDL + 1.6 RLL + 1.0 Rsec

219.34

527.86

527.86

219.34

Required d, (ACI 318, 11.0)

Required b0d, (ACI 318, 11-36)

3.04

4.90

4.90

3.04

For Vn < Vu, the required

0.00

0.00

0.00

0.00

Not ReqD

Not ReqD

Not ReqD

Not ReqD

column cap thickness, tcap (in)

8. CALCULATE COST FOR SLAB & CAP


Location
Concrete

Left

Mid of L1

Mid of L2

Support

Mid of LTyp

Right

1.67

5.00

5.00

5.00

cap concrete

0.00

0.00

0.00

0.00

Total =
length (ft)

Tendons

Support

cap dim (ft)

44.71

Rebars

97749

20.01

T / 30 ft TW
30.02

Total =

457.8

0.00

297.12

Total =

313.9

T / 30 ft TW
8.45

lb / ft2

Average =

100

Average =

0.468

lb / ft2 , (AISC Manual 2nd page 7-15)

0.321

lb / ft2

20.01
, (ACI 318 App. E)
297.12

0.00

T / 30 ft TW

44.71
Average =

Note:
1. The column moments are negligible for gravity punching design. Lateral loads, seismic and wind, should be supported by shear walls. Using equivalent frames to support lateral loads is not suggested.
2. By inspection, the deflections of slab do not govern PT concrete floor design. Otherwise, using PT concrete floor is inadequate for larger live load. (ACI 318, 9.5.4.1)
3. The secondary moments are very important concept of PT floor design. Based on this concept, PT floor design are always continuous beams design and one way slabs design. So using two
ways finite element analysis to design PT floor is inadequate.
Technical References:
1. "Design of Post-Tensioned Slabs Using Unbounded Tendons, Third Edition", The Post-Tensioning Institute, 2004.
2. "Design, Construction and Maintenance of Cast-in-Place Post-Tensioned Concrete Parking Structures, First Edition", The Post-Tensioning Institute, 2001.
3. Bijan O. Aalami & Allan Bommer, "Design Fundamentals of Post-Tensioned Concrete Floors, First Edition", The Post-Tensioning Institute, 1999.

__
Page 174 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Design of Post-Tensioned Concrete Floor Based on ACI 318-08


1. DESIGN METHODS
1.1 BREAKDOWN TWO WAYS FLOOR INTO DESIGN STRIPS IN ONE DIRECTION AND ONE WAY SLABS IN OTHER
DIRECTION. DESIGN STRIPS WORK AS CONTINUOUS BEAMS BY BANDED ALL TENDONS AT COLUMN. THE
PERPENDICULAR DIRECTION LIKE MULTI-SPAN ONE WAY SLABS, USING DISTRIBUTED TENDONS.
1.2 SPECIFY TOTAL REQUIRED EFFECTIVE POST-TENSIONING FORCES AT BANDED TENDONS, ON STRUCTURAL DRAWINGS,
AND UNIFORM FORCES IN DISTRIBUTED TENDONS.
1.3 WHEN TENDON LESS THAN 140 FT, STRESS AT ONE END. OTHERWISE STRESS AT BOTH ENDS.
1.4 THE VARIOUS LIVE LOADING CONDITIONS SHOULD BE CONSIDER BY INPUT LL ZERO AT SOME SPANS.

2. INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

f'c

REBAR YIELD STRESS

fy

TENDON PROPERTIES

fpu

=
=
=
=
=
=
=
=
=
=
=
#
#

fpy
fse
dia
Aps
SLAB THICKNESS

TRIBUTARY WIDTH IF BANDED AS DESIGN STRIPS

COLUMN WIDTH

c1

COLUMN DEPTH

c2

TOP BAR SIZE AT COLUMN


BOTTOM CONTINUOUS BAR SIZE

Location

Mid of L1

Left

Support

Mid L2
20

DL (psf)

120

120

LL (psf)

75

75

75%

75%

dCGS (in, from bottom)

3.33

Total if banded (kips)


Tendons

3.33

Required column cap thk, (in)

669.4
1 / 2 in Dia @ 14 in o.c.
26
7 # 5 , L = 6.06 ft

# 4 @ 73in. o.c.
Not ReqD

ski

1/2
0.153

in
in2

in

30

ft

22

in

CONCRETE COST =

THE DESIGN IS ADEQUATE.

22

in

TENDONS COST =

0.431

lb / ft2

REARS COST =

0.157

lb / ft2

100

lb / ft2

26

Bot Bars, Cont., E. Way

ski

175

22.31

669.4

7 # 5 , L = 3.03 ft

243

Right

1 / 2 in Dia @ 14 in o.c.

Total Number if banded


Top Bars at Column

7.5

22.31

ski

20

REQD EFFECTIVE PT (k / ft)

ski

270

Span (ft)

Balanced DL (60%-80% suggested)

ski

60

7 # 5 , L = 3.33 ft

# 4 @ 73in. o.c.
Not ReqD

Not ReqD

3. DESIGN LOADS & SECTION FORCES


Location

Left

Mid of L1

Support

Mid L2

MDL (ft-k / ft)

0.00

3.50

-5.00

3.50

0.00

MLL (ft-k / ft)

0.00

2.19

-3.13

2.19

0.00

0.00

-2.63

3.75

-2.63

Balanced Load (psf, uplift)


Balanced MBal (ft-k / ft)

-90

Required Effective PT (k / ft)

-90

22.31

Tendon Spacing (in)


0.00

-1.25

Secondary MSec (ft-k / ft)

0.00

1.38

0.00

22.31

14

Primary MFe (ft-k / ft)

Right

14
6.51
6.51

-1.25

0.00

2.76

1.38

0.00

Right

2.76

4. CHECK SERVICE LOAD STRESSES


Location

Left

Mid of L1

Support

Mid L2

A (in2 / ft)

96

96

96

96

96

S (in3 / ft)

128

128

128

128

128

F / A (ksi)

0.232

0.232

0.232
0.232

Check 125 psi < F /A < 275 psi


M / S + F / A , (ksi)

[Satisfactory]

0.232

0.314

0.232

0.150

for load combination (DL + PT)

- M / S + F / A , (ksi)

M / S + F / A , (ksi)

0.232

0.520

0.232

-0.055

Check ft < 7.5 (fc')0.5 and fc < 0.6 fc'

__
0.232

0.232

(ACI 318-08, 18.3.3 & 18.4.2a),

where

0.45 fc' =

0.530

0.45 fc' =

2.250

where

7.5 (fc')0.5 =

0.530

0.6 fc' =

3.000

-0.178

-0.178

for load (DL + LL + PT)

0.150

[Satisfactory]

for load (DL + LL + PT)

- M / S + F / A , (ksi)

0.314

0.350
0.350

Check ft < 7.5 (fc')0.5 and fc < 0.45 fc'

0.232

(ADAPT suggestion)

0.115
0.115

for load combination (DL + PT)

0.232

0.520

0.232

0.643

0.643

[Satisfactory]

-0.055

0.232

(ACI 318-08, 18.3.3 & 18.4.2b),

Page 175 of 533


524

(cont'd)

5. CALCULATE NON-PRESTRESSED REINFORCEMENT


Location

Left

Max. Nc (k / ft), (ACI 318, 18.0)

Mid of L1

Support

Mid L2

0.250

As (in2 / ft), (ACI 318, 18.9.3.2)


Bottom Bars, Each Way

Right

0.250

0.000

0.000

Not ReqD

Not ReqD

Max. Acf (in2), (ACI 318, 18.0)

2880

2880

2880

As' (in2), (ACI 318, 18.9.3.2)

2.160

2.160

2.160

7#5

7#5

7#5

3.03

6.06

3.33

Top Bars at Column


L (ft), (ACI 318, 18.9.4.1)

6. CHECK FLEXURAL CAPACITY BY STRENGTH DESIGN METHOD


Location
Factored Mu (ft-k / ft)

Left

Mid of L1

Support

Mid L2

Right

0.00

9.08

-8.24

9.08

0.00

4.67

4.00

1.2 MDL + 1.6 MLL + 1.0 MSec

-8.24

dp (in)

4.00

4.67

7.50

0.00273

0.00234

0.00146
0.00146

0.00234

0.00273

L / dp

60.00

51.39

32.00

51.39

60.00

fps (ksi)

186.25

187.27

214.46
187.27

186.25

0.131

0.131

0.131

(ACI 318, 18.7.2, b & c)

191.59

Aps (in2 / ft)

0.131

Actual Area
d (in)

0.131

0.131

6.63

6.75

6.63

6.75

6.63

a (in)

0.19

0.52

0.26
0.52

0.19

0.27
Required As (in2 / ft)
Bottom Bars, Each Way
Actual As (in2 / ft)

0.033
# 4 @ 73in. o.c.

0.033

Required As' (in2)


Top Bars at Column

0.033
# 4 @ 73in. o.c.

0.000

0.000

Not ReqD

0#5

Not ReqD

2.170

2.170

Actual As' (in )

2.170

Mn (ft-k / ft)

-9.28

9.08

Actual Capacity

-17.66
-16.00

Check Mn > Mu
pt, (ACI 318, 18.8.1)

0.033

0.000

9.08

-9.28

[Satisfactory]
0.0469

0.0186

c(dp - a / 1) / (a / 1)

0.0669
0.0648

Check pt > 0.005

0.0186

[Satisfactory]

0.0469
(ACI 318, 18.8.1)

7. CHECK PUNCHING SHEAR CAPACITY BY STRENGTH DESIGN METHOD


Location

Left

RDL (k)

Mid of L1

35.99

Support

Mid L2

72.02

Right
35.99

RLL (k)

22.50

45.01

22.50

RSec (k)

-26.99

-54.01

-26.99

52.19

104.42

52.19

Vu =1.2 RDL + 1.6 RLL + 1.0 Rsec

219.36

438.91

219.36

Required d, (ACI 318, 11.0)

Required b0d, (ACI 318, 11-36)

3.04

4.19

3.04

For Vn < Vu, the required

0.00

0.00

0.00

Not ReqD

Not ReqD

Not ReqD

column cap thickness, tcap (in)

8. CALCULATE COST FOR SLAB & CAP


Location
Concrete

Left

Mid of L1

Mid of L2

Right

1.67

5.00

5.00

cap concrete

0.00

0.00

0.00

Total =
length (ft)

Tendons

Support

cap dim (ft)

44.71

Rebars

56926

20.01

T / 30 ft TW

lb / ft2

Average =

100

Average =

0.431

lb / ft2 , (AISC Manual 2nd page 7-15)

Average =

0.157

lb / ft2

20.01

Total =

245.4

6.71

89.43

Total =

89.3

T / 30 ft TW
6.71

, (ACI 318 App. E)


49.23

T / 30 ft TW

Note:
1. The column moments are negligible for gravity punching design. Lateral loads, seismic and wind, should be supported by shear walls. Using equivalent frames to support lateral loads is not suggested.
2. By inspection, the deflections of slab do not govern PT concrete floor design. Otherwise, using PT concrete floor is inadequate for larger live load. (ACI 318, 9.5.4.1)
3. The secondary moments are very important concept of PT floor design. Based on this concept, PT floor design are always continuous beams design and one way slabs design. So using two
ways finite element analysis to design PT floor is inadequate.
Technical References:
1. "Design of Post-Tensioned Slabs Using Unbounded Tendons, Third Edition", The Post-Tensioning Institute, 2004.
2. "Design, Construction and Maintenance of Cast-in-Place Post-Tensioned Concrete Parking Structures, First Edition", The Post-Tensioning Institute, 2001.
3. Bijan O. Aalami & Allan Bommer, "Design Fundamentals of Post-Tensioned Concrete Floors, First Edition", The Post-Tensioning Institute, 1999.

__
Page 176 of 533
524

$"+% *

- . $"

/01

2/ ,-(* %

"

#$

&'

#$

&'

#$

+,"

%.

)/0/1

"+,"

%.

)/0/1

)*
2%#
3

!.9@ % 5-;$ 2;H-6:K !


H2%.% 33I.

!" #$% &' () "* "+,$%-! *$ $**$)

2 %#

/+2%#
5 -

;-3

2 6

/ ++ #$
+
,5 )/6

%.4-%

1"

'

#$

; ;4$

%. - I$
3

%.4-%
,5

)/6

&

;I % %% -< 9=
H2%.% 33I.

"0++

4
:

+/+

4
:

5
3.
@-

-85 .$ 394 93 -<#;.(%=<%) 93% :9 %=;-

"

3.

>1,>

-8 2%9.8

>1,>

-8$%- ;-

"/,>

-8 2%9.8

"/,>

-8$%- ;-

5( 6

AB&+

/+

)/0/18 9:4
% +;."6

1+,"

@-

)/0/18 9:4
% 0;./&6

AB&"+

C&"9

C&>/

5/D E,26,

8 +&

/&'

85 6

&1'

85

/0'1

&/>

85

" "

8/

+/>)&>

FG 85

FG

%-=? 6

1)&'8 %3 /+ + /6

H2%.%

8I 7 =;H-

( &

&0

/'

1)&' %3 //""6
%3 /+/+6

9: /+ )/6

/'

9: /+ )/6

&

#$

#$

/+

&/>

5J%.$ 394 % @ 3 #93$;.6

,/"

%3 /+" 96

A
!

D5&0

5&0

)!J 6%

>1 1 #$)

)!J 65&' 6

" 0/ #$)

8$2%.%#;.% =% <- $%- ;-9-32;.

(
C5! )&0
H2%.%

6, D
5 D

K, F

5A 8

6
+&

&>

( % @3

$(

4
: ,:;4
$

5$;$94:;4
$ 6
- ):;4
$
'"&&

K &'
(

1/1

6)"

(%=<%) 93%

/&&

5 =.%3$ ;-<;J%.- 6

//,+

( % @ 3 (%=<%) 93%

9=9 $%=

594
4
;H9:4
% -3.%9 %L

J94
I%6
/ &' + 6

)/0/1 %3 " /

)/0/1 %3 " /

(
! ,
H2%.%

/&&
5

5 , $6D 5 , $6

$(

4
: ,:;4
$

(%=<%) 93%

)/0/1 %3 "
/&&/

( % @ 3 (%=<%) 93%
6

/ & C

!" #$

&' (

% ) %% $

& %

" %

%(*+ (**)( ,

) -./ ) 0- '(#%

#$

&'

#$

&'

#$

+,'

)*

%.

)+/+0

1%#

'

%.

)+/+0

#$

'
,5 )+6

%.4 -%

7
'

)+6

9+7

9+

5 -

+&

1 %#

<-2 1 6

<

+7

<4$

%. - J$

95" : 4 6

%. - J$

5+3

+ 1 %#

%.4 -%

* 58398+&98+'6

#$

,5

;4<-=1<.> 4 -%
#$

2.%I

%
%

<

"
%

$JA ? ;2 -= %. - J$

!.;:% 5-<$ 1<I-6@L !


I1%.% 22J.

<--%2$<.@L !

)*

?
$
$

)*

4@

'' /

4@

)+/+09 ;@4% / <.+&6

)+/+09 ;@4%

-95 .$ 2;4

<. 6

;2-=#<.(%A=%) ;2% @; %A<-

2.

+,3

:-

' ,

2.

"+,'

-9 1%;.9

"+,'

-9$%- <-

:-

' ,

-9 1%;.9

' ,

-9$%- <-

5( 6
+

++70

CD&

CD&

E& ;

E &3+

+ &"

95 6

&0"

95

&+3

95

( &'

,+

5+F'>,16,

9' &

9+ 7

+3)&3

G H 95

GH

0)&"9 %2 +

I1%.%

' "7

%-AB 6

&7+

9J ? A<I-

>

+"

%2 + + 6

F5&/

5&/
(

&+3

;@ + 7)+6

;@ + 7)+6

'&

#$

)!K 6%

/ " #$)

)!K 65&" 6

73 #$)

E5! )&/

6, F
'5 F

L, G

#$

%2 +

';6

9$1%.%#<.% A% =-$%- <-;-21<.

/7+

6)

5 C' 9

'

6
+3

&3

( % :2

$(

4@ ,@<4$

5$<$;4 @<4$ 6
-')@<4$
+'/7

L &"
5

( % : 2(%A=%) ;2%

5 A.%2$ <-=<K%.- 6

;A; $%A

+ +,

(%A=%) ;2%

K;4J%6

5;44<I;@4% -2.%; %M

+ &&

)+/+0 %2

)+/+0 %2

+7&"
'+

'6
6

)*
! ,

7 &

$(

4@ ,@<4$

(%A=%) ;2%

I1%.%
(

)*
I1%.%

5K%.$ 2;4 % : 2 #;2$<.6

0)&" %2 ++

+"

1
(

+6

&/7

+ &&

)*

5 , $6F 5 , $6

+&&

( % : 2(%A=%) ;2%
'+

)+/+0 %2

' '6

+ '& E

!
!

F5&/

5&/

)!K 6%

/ " #$)

)!K 65&" 6

73 #$)

5 )/
5

6,

9
'

9$1%.%#<.% A% =-$%- <- 2.%I


;=% 36

4@ ,$<$;4 2.%I

+ +,
E

2.%I

+ 0

4@ , 2.%I
+ 7+

4@

! "#

! $

$%&' %&&(% )

(* +,-*(* .+*/%"$

' ()*+ ) ,+ ) "(*

"#

$%

&

$%

)
+ .

+ /

%@= M 2< 45 97 4 @%

3449<%37:B !

+ (&/ 0 1-

21
345 %3 6378 149

"

21
345 :3%%30 6378 149

$%

21
345 ;97% <219=59
"&
> ( 9 + 3-

$%

+ 63@4%9= 34 A21
1341
B

3 <79A 34 %3 H
:3%
6378149 97 4 @%

(C -

DE,

DE, /
,&

F, *

( G"8H6-H

+" ,

IJ

IJ + (

#K,&+ 9<

A6979

+( -

, #&

+(

, L*

, *

+(

,"

C ,"

F, /2

H /

, *

, L.

&

9<

2:

.K -

2:

.K -

9<

/ "2-

+ @ M =3A4

(;97% <21 9 0 <$2<%37-

&

",

$%

#K,& 9<

/ /-

$%
(

'
!

G( G ! -

/ L/ $%K

! ,&

"" $%K

( K/L/ +
H

4%+

"&

1
: H%3

259 /*<79A

H
F

4%+

/*L

1
: H;97% 9=59

( K/L/
G!

4+

&"

4+

L#L

<79A

1
: H <79A

<79A

1
: H <79A

/.

1
:

&/*

1
:

&L",

1
:

&L",

1
:

259 /*-

1
: H%3%21 <79A

H
F

*
I

H
F

<79A

#,

1
: H <79A

"

<79A

#,

1
: H <79A

1
: H%3%21 <79A

"

!!"

# !$!

!
"

#$
#$

#$
4 ,#

"
% &
'()*+,

"

' -$

"

% &

/0
4,#

"

::

:;33

'

,)

%1213

'

,)

%1213

%12137 *(8
, 119

8
(
8
(

%12137 *(8
, -)"9

+)

0 /"

'

<'

1/:

'

+)

3/0

'7 4,*)7

3/0

'7$,' -'

<'

1/"

'7 4,*)7

1/"

'7$,' -'

6. 9

=>?

=>? :"

@ ? "*

@?;

61A:B/49/

71 ?

? 0"

76

? ;?

76

: 11

? 1?

76

71 ;

CD

C D 76

3%? 7 ,+ 1

E4,),

9
*

,+ 1 1 9

*( 1

%19

*( 1

%19

1
1

7F 5 G-E'

4
.

. ?:

/1"

3%?

#$

? 1?

6H,)$ +*8 , < +#*+$-)9

,+ 1 " :*9

.
@6! A

9/

I/ C

E4,),

::;

:?
! 6

A !H 9

1:

2:1;

"0

'

?0

. , <+

1 1/

.,GJ,% *+,
+
"0
1:

. , < + .,GJ,% *+,

6$-$*8(-8
$ 9

A 9A6

6 =: 7

8
( / (-8
$

1 ??

#$%
':%(-8
$

*G* $,G

6*8
8
-E*(8
, '+),* ,K
6

H*8
F,9
1;?

%1213 ,+ " : 1

:9
9

'7< ' G $*'+, #)-< (-8


$ $- 8
*(,GJ,
'7< ' (-8
$

*+'J

.
! /
E4,),

1?

8
( / (-8
$

.,GJ,% *+,

1 ??
6

/ $9 A 6

/ $9

. , < + .,GJ,% *+,

%1213 ,+ " : 1

%1213 ,+ " : :9
? 230

1 :?

,+11 " "9

#$

19

? "

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Concrete Pool Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
fc'

ksi

REBAR YIELD STRESS

fy

60

ksi

LATERAL SOIL PRESSURE

Pa

45

pcf

CONCRETE STRENGTH

(equivalent fluid pressure)


BACKFILL WEIGHT

110

pcf

SURCHARGE WEIGHT

ws

50

psf

SEISMIC GROUND SHAKING


PE
=
20
psf /ft, ASD
(soil pressure, if no report 35SDS suggested. )
POOL DEPTH
H
=
6
ft
THICKNESS OF WALL

tw

THICKNESS OF SLAB

ts

SLAB REBARS
#
5
@
10
WALL VERTICAL REBARS
#
5
@
WALL BAR LOCATION (1=at middle, 2=at each face)

in
in
in o.c. at mid
8
in o.c.
1
at middle

LAP LENGTH

Ls

36

in

SLAB THICKER DISTANCE

ft

[THE WALL DESIGN IS ADEQUATE.]

ANALYSIS
DESIGN CRITERIA
1.
THE CRITERICAL DESIGN, FOR REBAR AT MIDDLE OR EQUAL OF EACH FACE, IS POOL WALL AT INWARD
SOIL PRESSURE BEFORE RESTRAINED AT TOP AND POOL FILLED.
2.
SINCE THE WALL AXIAL LOAD SMALL AND SECTIONS UNDER TENSION-CONTROLLED (ACI 318-08, 10.3.4), ONLY
CHECK WALL FLEXURAL CAPACITIES ARE ADEQUATE.
SINCE THE SLAB AT FLEXURAL & AXIAL LOADS, THE COMBINED CAPACITY OF FLEXURAL & AXIAL MUST BE CHECKED.
3.
SERVICE LOADS
Hb = 0.5 Pa (H + ts)2

=
=
=

Hs = ws Pa (H + ts) / b
2
HE = 0.5 PE (H + ts)

0.95

kips / ft

0.13

kips / ft

0.42

kips / ft

FACTORED LOADS
Hb = 1.6 Hb

=
=
=

Hs = 1.6 Hs
HE = 1.6 HE

1.52 kips / ft
0.21 kips / ft
0.68 kips / ft

CHECK WALL FLEXURE CAPACITY (ACI 318-08, 15.4.2, 10.2, 10.5.4, 7.12.2, 12.2, & 12.5)
Mu = (0.5 Hs + 0.33 Hb + 0.67 HE) H =

6.38

Pu =

1.19

kips / ft, (concrete wall self weight)

d =

4.00

in,

M n = AS f
ProvD =

0.010

b =

AS f y P u
1.7bf c'
<
>

MAX =
MIN =

12
=

7.46

0.015
0.004

in,

ft-kips / ft, (entire lateral loads used conservatively)

As =

0.465

ft-kips / ft

>

in / ft

Mu

[Satisfactory]

[Satisfactory]

__

CHECK WALL SHEAR CAPACITY (ACI 318-08, 15.5.2, 11.1.3.1, & 11.2)
Vu = Hs + Hb + HE =

V n = 2 bd

'
c

2.41

kips / ft, (entire lateral loads used conservatively)

3.94

kips / ft

Page 181 of 533


524

>

Vu

[Satisfactory]

(cont'd)
CHECK SLAB COMBINED CAPACITY OF FLEXURE & AXIAL (ACI 318-08, 10)
ProvD =

< MAX = 0.08 (for compression, ACI 318-08, 10.9.1)


> MIN = 0.0018 (for flexural, ACI 318-08, 10.5.4)
[Satisfactory]
0.01033

120.0
AT AXIAL LOAD ONLY
AT MAXIMUM LOAD
AT MIDDLE
AT t = 0.002
AT BALANCED

100.0
80.0
Pn (k)

60.0

Pn

Mn

106.6
106.6
60.9
15.3
14.4

0.0
3.9
7.2
5.5
5.4

AT t = 0.005

5.3

5.3

AT FLEXURE ONLY

0.0

4.4

(Note: For middle reforming the max M n is at c

40.0

equal to 0.5 t / 1 , not at balanced condition.)


20.0
0.0
0.0

2.0

4.0

6.0

8.0

Pu =

2.41

kips / ft

Mu =

1.25

ft-kips / ft

Mn (ft-k)

[Satisfactory]

CHECK REBAR DEVELOPMENT

L d = MAX

requird 0.075 t e sd b f
provided
f c' c + K tr

, 12 in =

26 db

db

where

Bar size
db

#
=

16

in, (ACI 318-08, 12.2.3)

<

Ls

5 , (governing size)
0.625 in

required / provided =

( As,reqd / As,provd, ACI 318-08, 12.2.5)

1.0 (1.3 for bottom cover more than 12", ACI 318-08, 12.2.4)

1.0 (1.2 for epoxy-coated, ACI 318-08, 12.2.4)

0.8 (0.8 for # 6 or smaller, 1.0 for other)

=
=

1.0 (0.75 for light weight, ACI 318-08, 12.2.4)


3.3 in, min(d' , 0.5s), (ACI 318-08, 12.2.4)

Ktr

(c + Ktr ) / db =

(Atr fyt / 1500 s n) =

(ACI 318-08, 12.2.4)

2.5 < 2.5 , (ACI 318-08, 12.2.3)

__
Page 182 of 533
524

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
Two-Way Slab Design Based on ACI 318-11 using Finite Element Method

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH
fc' =
3
ksi
REBAR YIELD STRESS
fy =
60
ksi
COLUMN SPACING EACH WAY
L =
24
ft
B =
24
ft
SLAB THICKNESS
t =
9.5
in
BENDING DROP PANEL THK. (12.0 ft x 12.0 ft)
tdrop =
2.5
in
PUNCHING CAP THICKNESS
tcap =
0
in
COLUMN SIZE (SHORT EDGE)
c=
24
in
DEAD LOAD & SELF WT
DL =
150
psf
LIVE LOAD
LL =
70
psf
TOP BARS AT COLUMNS EACH WAY
6
#
6
@
12
o.c.
x
8.0
ft. long,
with
0.75
in. cover
(All top bars to column strip suggested, if column strip & middle strip used.)
BOTTOM LAYER BOTTOM BARS
#
5
BOTTOM LAYER TOP BARS
#
5

18

THE DESIGN IS ADEQUATE.

o.c.

@
18
o.c.
with
0.75
in. bottom concrete cover
(75% total bottom bars to middle strip & 25% to column strip suggested, if column strip & middle strip used.)
ANALYSIS
wc =
te =

150
( Ie / Ig )

1/3

Ec = wc1.5 33 f'c0.5 =

pcf, (ACI 318-11 8.5.1)


t = (0.25 Ig / Ig )

Joint

Ru

Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

in
0
0.29
0.53
0.29
0
0.29
0.46
0.64
0.46
0.29
0.53
0.64
0.75
0.64
0.53
0.29
0.46
0.64
0.46
0.29
0

kips
42.05

22

0.29

23
24

0.53
0.29

25

1/3

42.05

1/3

t = (0.25)

t=

Bending
Section
1-2
2-3
1-6
6 - 11
3-8
8 - 13
11 - 12
12 - 13

0.63

t=

6.0
8.5

3321

ksi, (ACI 318-11 8.5.1)

in, for Slab only (ACI 318-11 9.5.3.4 & 10.10.4.1)


in, for Slab & Drop Panel

Mu
ft-k/ft
12.9
-0.2
12.9
-0.2
-0.5
-6.0
-0.5
-6.0

DETERMINE FACTORED LOAD (ACI 318-11 9.2.1)


wu = 1.2 DL + 1.6 LL =
0.292
ksf
DETERMINE FLEXURE CAPACITY (ACI 318-11 7.12.2.1, 10.2, 10.5.1)
Top Bar
6 # 6 @ 12" o.c.
10.13

Bot. Layer Bot.


5 @ 18" o.c.
8.44

Bot. Layer Top


5 @ 18" o.c.
7.81

As (in2/ft)

0.44

0.21

0.21

As, min (in2/ft)


a (in)

0.41
0.86

0.21
0.41

0.21
0.41

Mn (ft-k/ft)

19.2

7.7

7.1

d (in)

42.05

42.05

CHECK FLEXURE CAPACITY


Mu,Top = Max( Mu,1-2 , Mu,1-6 ) =

12.9

ft-k/ft

Mu,Bot,Bot = - Min( Mu,8-13 , Mu,12-13 ) =

6.0

ft-k/ft

Mu,Bot,Top = - Max( Mu,8-13 , Mu,12-13 ) =

6.0

ft-k/ft

<
<
<

Mn =

19.2

ft-k/ft

[Satisfactory]

Mn =

7.7

ft-k/ft

[Satisfactory]

Mn =

7.1

ft-k/ft

[Satisfactory]

(cont'd)
CHECK LIVE LOAD DEFLECTION (ACI 318-11 Table 9.5b)
LL = u,Max LL / (1.2 DL + 1.6 LL) =
0.18

<

in

L / 360

0.80

in

[Satisfactory]
CHECK LONG-TERM DEFLECTION (ACI 318-11 9.5.2.5)
3DL + LL = u,Max (3DL + LL) / (1.2 DL + 1.6 LL) =

1.33

in
[Satisfactory]

<

CHECK COLUMN PUNCHING CAPACITY (ACI 318-11 11.11.1.2, 11.11.7, & 13.5.3.2)
Pu = 4 Ru,max =
168.2
kips
(See Punching.xls Software for More Information.)

V n = ( 2 + y )
where

'

f c Ap =

0.75

227.10

>

kips

(ACI 318-11, Section 9.3.2.3 )

c =
d=
b0 =

1.00
10.1
in
4c+4d=

136.5

Ap =

b0 d =

in

y=

MIN(2 , 4 / c , 40 d / b0) =

1382.1

in

2.0

Pu

[Satisfactory]

L / 180

1.60

in

PROJECT :
CLIENT :
JOB NO. :
DATE :
Two-Way Slab Design Based on ACI 318-11 using Finite Element Method

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH
fc' =
3
ksi
REBAR YIELD STRESS
fy =
60
ksi
COLUMN SPACING EACH WAY
L =
24
ft
B =
24
ft
SLAB THICKNESS
t =
9.5
in
BENDING DROP PANEL THK. (12.0 ft x 12.0 ft)
2.5
in
tdrop =
PUNCHING CAP THICKNESS
tcap =
0
in
DEAD LOAD & SELF WT
DL =
150
psf
LIVE LOAD
LL =
70
psf
TOP BARS AT COLUMNS EACH WAY
6
#
6
@
12
o.c.
x
8.0
ft. long,
with
2
in. cover
(All top bars to column strip suggested, if column strip & middle strip used.)
BOTTOM LAYER BOTTOM BARS
#
5
BOTTOM LAYER TOP BARS
#
5

18

THE DESIGN IS ADEQUATE.

o.c.

@
18
o.c.
with
0.75 in. bottom concrete cover
(75% total bottom bars to middle strip & 25% to column strip suggested, if column strip & middle strip used.)

ANALYSIS
wc =
te =

150
( Ie / Ig )

1/3

Joint

Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

in
0
0.30
0.56
0.32
0
0.30
0.47
0.62
0.33
0
0.54
0.64
0.68
0.34
0
0.30
0.47
0.62
0.33
0
0
0.30

23
24
25

0.56
0.32
0

Ec = wc1.5 33 f'c0.5 =

pcf, (ACI 318-11 8.5.1)


t = (0.25 Ig / Ig )

CHECK FLEXURE CAPACITY


Mu,Top = Max( Mu,1-5 , Mu,1-11 ) =
Mu,Bot,Bot = - Min( Mu ) =

1/3

t = (0.25)

Bending
Section
1-2
2-3
3-4
4-5
1-6
6 - 11
12 - 13
13 - 14
7 - 12
8 - 13
9 - 14

1/3

t=

0.63

t=

6.0
8.5

3321

ksi, (ACI 318-11 8.5.1)

in, for Slab only (ACI 318-11 9.5.3.4 & 10.10.4.1)


in, for Slab & Drop Panel

Mu
ft-k/ft
13.3
-0.6
-2.3
12.9
13.2
-0.3
-6.9
-6.8
-7.3
-5.8
-2.8
DETERMINE FACTORED LOAD (ACI 318-11 9.2.1)
wu = 1.2 DL + 1.6 LL =
0.292
ksf
DETERMINE FLEXURE CAPACITY (ACI 318-11 7.12.2.1, 10.2, 10.5.1)

d (in)
As (in2/ft)

Top Bar
6 # 6 @ 12" o.c.
8.88
0.44

Bot. Layer Bot.


5 @ 18" o.c.
8.44
0.21

Bot. Layer Top


5 @ 18" o.c.
7.81
0.21

0.36
0.86
16.7

0.21
0.41
7.7

0.21
0.41
7.1

As, min (in2/ft)


a (in)
M n (ft-k/ft)

13.3

ft-k/ft

7.3

ft-k/ft

Mu,Bot,Top = - Max( Mu,12-14 , Mu,7-12 , Mu,8-13 , Mu,9-14 ) =

<
<
2.8

16.7

ft-k/ft

[Satisfactory]

Mn =

7.7

ft-k/ft

[Satisfactory]

7.1

ft-k/ft

[Satisfactory]

L / 360

ft-k/ft

<
CHECK LIVE LOAD DEFLECTION (ACI 318-11 Table 9.5b)
LL = u,Max LL / (1.2 DL + 1.6 LL) =
0.16

Mn =

Mn =

<

in

0.80

in

[Satisfactory]
CHECK LONG-TERM DEFLECTION (ACI 318-11 9.5.2.5)
3DL + LL = u,Max (3DL + LL) / (1.2 DL + 1.6 LL) =

1.20

in
<
[Satisfactory]

L / 180

1.60

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Voided Two-Way Slab Design Based on ACI 318-11


DESIGN CRITERIA
1.
The voided sphere or ellipse bubbles within slab can reduce concrete weight, so both seismic mass (ASCE 7 12.7.2) and gravity
loads reduced. And the long-term deflection (3 DL + LL) limits may not govern the two-way slab design (ACI 318 9.5).
2.
The entire slab bottom formwork can be flat, without girder, beam, drop panel or cap, but the punching area (ACI 318 11.11),
or lateral frame diaphragm area (ACI 318 21.11.9), may need to be solid as normal concrete shear transfer.
3.
The section forces of voided slab can be determined by a two-way finite element method or by ACI 318 Chapter 13, but PT slab
can only be designed by one way method because the secondary moment of PT slab is one way concept. Also, the voided
two-way slab is better for depressed floor,
or irregular opening, than PT slab.
4.
The bottom two direction rebar can be
distributed as a regular solid two-way slab,
without Waffle slab or hollow core plank limits.

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH
fc' =
4
ksi
REBAR YIELD STRESS
fy =
60
ksi
TOTAL SLAB THICKNESS
t =
18
in
TOP & BOTTOM SOLID THICKNESS
tsolid =
4
in
VOIDED BUBBLE HORIZONTAL DIAMETER
D =
20
in

COLUMN SPACING EACH WAY


L =
35
ft
B =
35
ft
COLUMN SIZE (SHORT EDGE)
c=
30
in
SUPERIMPOSED DEAD LOAD, ASD
DLsup =
20
psf
LIVE LOAD
LL =
70
psf

TOP BARS AT COLUMNS EACH WAY


17
#
7
@
6
o.c.
x
11.7
ft. long,
with
0.75
in. cover
(All top bars to column strip suggested, if column strip & middle strip used.)
BOTTOM LAYER BOTTOM BARS
#
6
BOTTOM LAYER TOP BARS
#
6

12

THE DESIGN IS ADEQUATE.

o.c.

@
12
o.c.
with
0.75
in. bottom concrete cover
(75% total bottom bars to middle strip & 25% to column strip suggested, if column strip & middle strip used.)

ANALYSIS
DETERMINE SECTION PROPERTY & DEAD LOAD
tsolid =
4
in
>

D =

20

in

0.75

1.75

>

0.75
(inside cover)

1.50
(2 rebar thick)

>

10

wc =

150

pcf, (ACI 318-11 8.5.1)

Wt =

173

psf, self weight reduced 23%

Isoild =

10935

1.5

Ec = w c
te =

0.5

33 f'c

3.25

in, top solid min thk

3.00

in, bot solid min thk


[Satisfactory]

V =

2094

ksi, (ACI 318-11 8.5.1)

9953

( Ig / Isoild ) Ec =
0.63

t=

11.3

[Satisfactory]

in3, volume of a voided sphere or ellipse bubble

DL = DLsup + Wt =
Ig =

( Ie / Ig )1/3 t = (0.25 Ig / Ig )1/3 t = (0.25)1/3 t =

0.75
=
(top & bot cover)

in, height of voided sphere or ellipse bubble

in4
3834

0.75

193

psf

in4
3490

ksi, for Finite Element Method

in, for Slab only (ACI 318-11 9.5.3.4 & 10.10.4.1)

(cont'd)
DETERMINE SECTION FORCE AND SLAB DEFLECTION USING FINITE ELEMENT METHOD
Joint
u
Ru
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

in
0
0.49
0.78
0.49
0
0.49
0.69
0.88
0.69
0.49
0.78
0.88
0.99
0.88
0.78
0.49
0.69
0.88
0.69
0.49
0

kips
105.33

Bending
Section
1-2
2-3
1-6
6 - 11
3-8
8 - 13
11 - 12
12 - 13

22

0.49

As (in2/ft)

1.20

0.44

0.44

23
24

0.78
0.49

As, min (in2/ft)


c (in)

0.64
2.20

0.39
0.84

0.39
0.84

25

Mn (ft-k/ft)

81.1

32.7

31.3

105.33

Mu
ft-k/ft
80.9
-3.7
80.9
-3.7
-1.7
-20.6
-1.7
-20.6

DETERMINE FACTORED LOAD (ACI 318-11 9.2.1)


wu = 1.2 DL + 1.6 LL =
0.344
ksf
DETERMINE FLEXURE CAPACITY (ACI 318-11 7.12.2.1, 10.2, 10.5.1)

Top Bar
17 # 7 @ 6" o.c.
15.94

d (in)

105.33

105.33

o =

Bot. Layer Bot.


6 @ 12" o.c.
16.88

2 0.85 f C'

CHECK FLEXURE CAPACITY


Mu,Top = Max( Mu,1-2 , Mu,1-6 ) =

80.9

ft-k/ft

Mu,Bot,Bot = - Min( Mu,8-13 , Mu,12-13 ) =

20.6

ft-k/ft

Mu,Bot,Top = - Max( Mu,8-13 , Mu,12-13 ) =

20.6

ft-k/ft

CHECK LIVE LOAD DEFLECTION (ACI 318-11 Table 9.5b)


LL = u,Max LL / (1.2 DL + 1.6 LL) =
0.20

<
<
<

, E s = 29000ksi

0.85 f

0.85 f

'
C

2
2 c c ,
o o

for 0 < c < o

'
C

, for c o

s E s , for s t
=
, for s > t
f

Mn =

81.1

ft-k/ft

[Satisfactory]

Mn =

32.7

ft-k/ft

[Satisfactory]

Mn =

31.3

ft-k/ft

[Satisfactory]

L / 360

<

in

Ec

Bot. Layer Top


6 @ 12" o.c.
16.13

1.17

in

[Satisfactory]
CHECK LONG-TERM DEFLECTION (ACI 318-11 9.5.2.5)
3DL + LL = u,Max (3DL + LL) / (1.2 DL + 1.6 LL) =

1.87

in
<
[Satisfactory]

L / 180

CHECK COLUMN PUNCHING CAPACITY (ACI 318-11 11.11.1.2, 11.11.7, & 13.5.3.2)
Pu = 4 Ru,max =
421.3
kips
(See Punching.xls Software for More Information.)

V n = ( 2 + y )
where

'
f c Ap =

0.75

>

555.65 kips

(ACI 318-11, Section 9.3.2.3 )

c =
d=
b0 =

1.00
15.9
in
4c+4d=

Ap =

b0 d =

y=

MIN(2 , 4 / c , 40 d / b0) =

2928.5

183.8
in2

in
2.0

Pu

[Satisfactory]

2.33

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Pipe Concrete Column Design Based on ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH
fc'
REBAR YIELD STRESS
fy
COLUMN OUTSIDE DIAMETER
D
CONCRETE WEB THICKNESS
T
FACTORED AXIAL LOAD
Pu
FACTORED MAGNIFIED MOMENT
Mu
FACTORED SHEAR LOAD
Vu
COLUMN VERT. REINFORCEMENT
8
LATERAL REINF. OPTION (0=Spirals, 1=Ties)
LATERAL REINFORCEMENT
#
4

=
=
=
=
=
=
=
#

5
60
20
7
480
190
20
7
1
12

ksi
ksi
in
in
k
ft-k
k

Ties
in o.c.

THE COLUMN DESIGN IS ADEQUATE.

ANALYSIS

o =

900
800

'
C

, E c = 57

Ec
0.85 f

'
C

600

0.85 f

'
C

500

sE s ,

700

Pn (k)

2 0.85 f

400
300

f y ,

c
c

o
o

, E s = 29000ksi

'
C

for 0 < c < o

for c o
for s y

for s > y
Pn (kips)
819
819

Mn (ft-kips)
0
70

200

AT AXIAL LOAD ONLY


AT MAXIMUM LOAD

100

AT 0 % TENSION

643

148

AT 25 % TENSION

533

180

AT 50 % TENSION

444

197

AT t = 0.002

318

206

AT BALANCED CONDITION

313

208

AT t = 0.005

146

229

164

0
0

50

100

150

200

250

Mn (ft-k)

AT FLEXURE ONLY

CHECK FLEXURAL & AXIAL CAPACITY

Pmax =0.85 [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

Ag =
a = Cb 1 =

819.1 kips., (at max axial load, ACI 318-08, Sec. 10.3.6.1)

2
286 in .

Ast =

0.65 + ( t - 0.002 ) (250 / 3), for Ties


where

Cb = d
d

4.80

Pu

c / (c + s)

164

Mn =

ft-kips @ Pu =

190

10

0.656

in

17.6 in, (ACI 7.7.1)

Mn = 0.9 n =

(ACI 318-08, Fig. R9.3.2)

t =

0.002069

1 =

0.8

c =

0.003

( ACI 318-08, Sec. 10.2.7.3 )

ft-kips @ Pn = 0, (ACI 318-08, Sec. 9.3.2) ,& t,min = 0.004, (ACI 318-08, Sec. 10.3.5)

>

480 kips

max

0.08 (ACI 318-08, Section 10.9)

min

0.01 (ACI 318-08, Section 10.9)

provd

Mu

[Satisfactory]

0.017
[Satisfactory]

CHECK SHEAR CAPACITY

Vn = (Vs + Vc) =

49

kips, (ACI 318-08 Sec. 11.1.1)

>

where

[Satisfactory]

2
in .

in (at balanced strain condition, ACI 10.3.2)

0.75 + ( t - 0.002 ) (50), for Spiral

>

0.65 (ACI 318-08, Sec.9.3.2.2)

=
A0 =

Vu
[Satisfactory]
0.75 (ACI 318-08 Sec. 9.3.2.3)
2
214 in .
0.5

Av =

Vc =

2 (fc') A0 =

Vs =

MIN (d fy Av / s , 4Vc) =

smax

14

smin

30.3

0.40

in2.

fy =

60

ksi

kips, (ACI 318-08 Sec. 11.2.1)


35.1

kips, (ACI 318-08 Sec. 11.4.6.2)

(ACI 318-08, Section 7.10.5.2)

sprovd

12

in
[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Anchorage to Pedestal Design Based on ACI 318-08 & AISC 360-05


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

f c' =

ksi

SPECIFIED STRENGTH OF ANCHOR

futa =

65

ksi

BASE PLATE YIELD STRESS

fy =

36

ksi

CRITICAL BASE PLATE CANTILEVER

m=

3.3

in

FACTORED AXIAL LOAD AT WORK POINT

Pu =

150

kips

FACTORED SHEAR LOAD AT WORK POINT

Vu =

16

kips, ( 0 if shear lug used.)

FACTORED MOMENT AT WORK POINT

Mu =

120

ft-kips

EFFECTIVE EMBEDMENT DEPTH

hef =

28

in

1
1.75
Yes
7
576

in
in

ANCHOR DIAMETER
BASE PLATE THICKNESS
SEISMIC LOAD ? (ASCE 14.2.2.17)
PEDESTAL VERTICAL REBAR SIZE
PEDESTAL HORIZONTAL SECTION AREA

d=
t=
== >
#
A2 =

in

ANCHOR LOCATION TO WORK POINT


X (in)
Y (in)
Anchor

1
2
3
4
5
6

-8
-8
-8
8
8
8

8
0
-8
8
0
-8

Work Point

BASE PLATE SIZE - 20 in x 20 in x 1.75 in (thk.)


X (in)
Y (in)
Corner
1
-9.75
-9.75
Edge = 1.75 in
2
-9.75
9.75
(AISC 360-05, Tab J3.4 & J3.5)
in2, base plate area
3
9.75
9.75
A1 =
400
4
9.75
-9.75
-9.75
-9.75

THE BASE PLATE & GROUP ANCHORS DESIGN IS ADEQUATE.


ANALYSIS
CHECK FLEXURAL & AXIAL COMPRESSION CAPACITY OF ANCHORED CONCRETE (ACI 318-08 Sec 9 & Sec 10)
1000

900
800
Pn (k)

700
600
500
400
300
200
100
0
0

100

200
Mn (ft-k)

__
300

400

Page 188 of 533


524

(cont'd)
Mn =

>
Pmax =

u, c =
939

>
Nua,1 =

fp =

ft-kips @ Pu =

210

123

150

kips

ft-kips to center of base plate


[Satisfactory]

o =

2 f C'

0.85Min

Ec

kips

Pu =

150

ft-kips

[Satisfactory]

4.42

fS=

ksi, the max possible concrete compression stress.


(ACI 318-08, 10.17.1 & 9.3.2.4, or AISC Guide - 1)

, E c = 57 f C' , E s = 29000ksi
2

0.85Min

A2 , 2 ' 2 c c
fC
o
o
A1

0.85Min

A2 , 2 ' , for
fC
c o
A1

fC=

12.50 kips
(The 2.5 times max tension, ASCE 14.2.2.17)

A2 , 2
A1

, for 0 < c < o

s E s , for s y
f y , for s > y

DETERMINE EACH ANCHOR FORCES WITHOUT CONCTERE COMPRESSION CAPCAITY CONSIDERED


2

Anchor
1
2
3
4

X (in)

Y (in)

XCG

YCG

Nua, 2

Vua

-8
-8
-8
8

8
0
-8
8

64
64
64
64

64
0
64
64

5.00
5.00
5.00
-55.00

2.67
2.67
2.67
2.67

XCG =
YCG =

64

-55.00

2.67

Pu,CG =

-8

64

64

-55.00

2.67

384

256

-150

0
0

in
in

150.0

kips

Vu,CG =

16.0

kips

Mu,CG, X =

120.0

ft-kips

Mu,CG, Y =

0.0

ft-kips

16

CHECK GOVERNING ANCHOR TENSILE STRENGTH (ACI 318, D.5.1.2)

N s = A se ( f
where :

uta

0.75

Ase

0.606

22.16

kips

x
in

0.75

>
=

Nua = Max( Nua,1 , Nua,2 ) =

12.50

kips

[Satisfactory]

0.5625 , (ACI 318-08 D.4.4 & D.3.3.3)

CHECK GOVERNING ANCHOR SHEAR STRENGTH (ACI 318, D.6.1.2b & ASCE 7-05 14.2.2.17)

V s = 0.6 Ase f ut
where :

11.52

0.65

k
0.75

>

Vua =

0.4875
(for built-up grout pads, first factor shall be multiplied by 0.8, ACI 318 D.6.1.3)

2.67

__

CHECK TENSION AND SHEAR INTERACTION OF GOVERNING ANCHORS : (ACI 318, D.7)
Since

Nua,2

>

0.2 Nn and

Vua,2

>

0.2 Vn the full design strength is not permitted.

The interaction equation must be used

N ua ,2

Nn

V ua ,2
=
V n

0.46

<

1.2

[Satisfactory]

Page 189 of 533


524

kips

[Satisfactory]

(cont'd)
CHECK BASE PLATE THICKNESS (AISC Guide - 1, Eq. 3.3.14a)

t reqD = 1.5m

Fy

1.73

<

in

t=

1.75

in

[Satisfactory]

CHECK SPLICE LENGTH OF TENSION ANCHOR WITH REBAR


L s = 1.3 L d =

25 db =

25

in, (ACI 318-08, 12.15.1,)

<
L d = MAX

where

requird 0.075 t e sd b f y
, 12 in =
provided
f 'c c + K tr
db

required / provided

19 db =

19

hef - 2" =

26

in

( A s,reqd / A s,provd , if not apply input zero, ACI 318-08, 12.2.5 & 12.15.1)

0.564

in, anchor governing

65

ksi

1.0

(1.3 for horizontal bar over 12" concrete, ACI 318-08 12.2.4)

1.0

(1.2 for epoxy-coated, ACI 318-08 12.2.4)

fy
t
e
s

1.0

(0.8 for # 6 or smaller, 1.0 for other)

=
=

1.0
2.3

(0.75 for light weight, ACI 318-08, 12.2.4)


in, (ACI 318-08, 12.2.4)

Ktr

(c + Ktr ) / db =

(Atr fyt / 1500 s n) =


2.3

[Satisfactory]

(ACI 318-08, 12.2.3)

db

in

(ACI 318-08, 12.2.3), (50 bw / 1500 n, for CBC 2001)

< 2.5 , (ACI 318-08, 12.2.3)

__
Page 190 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Plate/Shell Element Design Based on ACI 318-08


DESIGN CRITERIA
THE PLATE/SHELL ELEMENT CAN BE FROM BEARING WALL, DIAPHRAGM, TANK, OR OTHER SURFACE STRUCTURES. THE SOFTWARE
IS FOR ONE DIRECTION PERPENDICULAR BENDING AND SHEAR DESIGN, SINCE THERE ARE NO INTERACTION AT BOTH DIRECTIONS.

FOR IN PLAN LOADS, THE SHEAR WALL DESIGN SOFTWARE SHOULD BE USED.

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH

fc'

ksi

REBAR YIELD STRESS

fy

60

ksi

FACTORED AXIAL LOAD

Pu

30

kips / ft

FACTORED MOMENT

Mu

18

ft-kips / ft

FACTORED SHEAR LOAD

Vu

7.2

kips / ft

=
#

10
5

in

As LOCATION (1=at middle, 2=at each face)

at each face

THICKNESS OF ELEMENT
ELEMENT REINFORCING (As)

18

in o.c.

[THE ELEMENT DESIGN IS ADEQUATE.]

ANALYSIS
CHECK AXIAL & FLEXURE CAPACITY
< MAX = 0.0400 (tension face only, ACI 318-05 10.3.5 or 10.9.1)
ProvD = 0.00224
> MIN = 0.0008 (tension face only, ACI 318-05 10.5.1, 10.5.3 or 14.3.2)
[Satisfactory]

200.0
180.0
160.0
140.0
120.0
Pn (k)

100.0

Pn

Mn

AT AXIAL LOAD ONLY


AT MAXIMUM LOAD
AT MIDDLE
AT t = 0.002
AT BALANCED

171.5
171.5
115.5
59.5
58.1

0.0
8.0
19.3
22.5
22.6

AT t = 0.005

42.7

25.4

80.0

AT FLEXURE ONLY

0.0

7.0

60.0

(Note: For middle reforcing the max M n is at c


equal to 0.5 t / 1 , not at balanced condition.)

40.0
20.0

[Satisfactory]

0.0
0.0

5.0

10.0

15.0

20.0

25.0

30.0

Mn (ft-k)
CHECK SHEAR CAPACITY (ACI 318-08 SEC.15.5.2, 11.1.3.1, & 11.2)

V n = 2 bd f c'

__

7.58 kips / ft

>

Vu

Page 191 of 533


524

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Concrete Diaphragm Design for a Discontinuity of Type 4 out-of-plane offset irregularity


INPUT DATA
B=
L=
t=

OFFSET LATERAL SYSTEM DIMENSION


MAX TWO OUTSIDE PERPENDICULAR LATERAL SYSTEM SPAN
TRANSFER DIAPHRAGM THICKNESS
fy =

REBAR YIELD STRESS

60

18
32
8

ft
ft
in

ksi

fc' =
4
ksi
CONCRETE STRENGTH
LIGHTWEIGHT CONCRETE ? (ACI 318, 8.6)
Yes (Lightweight Concrete)
#
7
@
8
in, o.c.
TRANSFER DIAPHRAGM REINFORCEMENT
REINF. LOCATION ( 0 = one layer only, 1 = Top & Bottom)
1
,(top & bottom, each way)
COLLECTOR / CHORD REBARS AROUND TRANS. DIAPHRAGM
10
#
8
(the rebars must be closed trans. diaphragm & developed into vert. lateral system)
Vu =

680

kips

T u,drag =

165

kips

T u,chord =

60

kips

FACTORED SHEAR FORCE ON TRANSFER DIAPHRAGM SIDE


MAX. FACTORED COLLECTOR (DRAG) FORCE
MAX. FACTORED CHORD FORCE

THE TRANSFER DIAPHRAGM DESIGN IS ADEQUATE.


ANALYSIS
CHECK MINIMUM REINFORCEMENT RATIOS (ACI 318-08, 21.11.7 & 7.12)

(t )provd. = 0.0188

(t )min. =

>

0.0018

[Satisfactory]
CHECK DIAPHRAGM SHEAR CAPACITY (ACI 318-08, 21.11.9)
vu = 1.25 Vu / L =

34.5

kips / ft, (ASCE 7-05, 12.3.3.4 & Table 12.3-2.4)

vn = MIN [ Acv (2 (fc')0.5 + t fy), 8 Acv (fc')0.5 ] =


36.4

=
where
1.3
(ASCE 7-05, 12.10.1.1 & 12.3.4.2)

Acv =

0.75
96

0.75

kips / ft

>

vu

[Satisfactory]

(ACI 318-08, 9.3.2.3)


in2
(ACI 318-08, 8.6.1)

CHECK DIAPHRAGM IN-PLANE FLEXURAL CAPACITY, USING DISTRIBUTED REINFORCEMENT ONLY (ACI 318-08, 21.11.9)
Mu = 1.25 Vu B =
Mn =

19890.0

20011.3

ft-kips, the max value same at both B & L sections, (ASCE 7-05, 12.3.3.4 & Table 12.3-2.4)

ft-kips, by pure math method

where 1

0.85

(ACI 318-08, 10.2.7.3)

cu

0.003

(ACI 318-08, 10.3.2)

dt = MIN( B , L) =
c=

74

Es =

>

Mu

[Satisfactory]

216 in, (ACI 318-08, R10.3.3)


in, (ACI 318-08, R10.3.3)

29000 ksi, (ACI 318-08, 8.5.2)

ec =

76

in, (eccentricity of total concrete compression force)

es =

61

in, (eccentricity of total steel tension force)

CHECK COLLECTOR / CHORD REBAR CAPACITY (ACI 318-08, 10.2.4)


Tu = MAX( 1.25 Tu,chord , 0 Tu,drag) =
Tn = fy As =
where 0

426.6
=

As =

2.5
7.9
0.90

kips

>

412.5
Tu

(ASCE 7-05 Tab 12.2-1)


in2
(ACI 318-08, 9.3.2.1)

kips, (ASCE 7-05, 12.10.2.1, 12.3.4.1, 12.3.3.4 & Table 12.3-2.4)


[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Concrete Silo / Chimney / Tower Design Based on ASCE 7-05, ACI 318-08 & ACI 313-97
INPUT DATA
BIN DEPTH

H=

150

ft

dia =

30

ft

t=

12

in, at bottom

in, at top )

FOOTING DIAMETER

D=

61

ft

FOOTING THICKNESS

T=

48

in

Hp =

24

in

BIN OUTSIDE DIAMETER


BIN CONCRETE THICKNESS

SOIL DEPTH TO BOTTOM


WT OF BIN MAX CONTENTS

W bin = 5763.4 kips, (input zero for chimney)

WT OF TOP CAP

W cap = 180.96 kips

MAX HORIZONTAL PRESSURE

p=

ALLOWABLE SOIL PRESSURE

Qa =

5.5

ksf

PASSIVE PRESSURE

Pp =

450

psf / ft

SOIL FRICTION COEFFICIENT


CONCRETE STRENGTH

REBAR YIELD STRESS


FOOTING REBAR

2
@

9360

psf, (H for water, or from ACI 313 4-2)

0.35

fc' =

ksi

fy =

60

ksi

Layers
14

10

in o.c. each way, at top & bot.


#

REBAR LOCATION (1=at middle, 2=at each face)

DOWEL / BIN VERTICAL REBARS

BIN HORIZONTAL REBARS

12

in o.c.

at each face
@

12

in o.c.

WALL HORIZONTAL PRESTRESSING TENDONS, (input strands zero for non-prestress)


11

strands

24

in o.c.

(each

0.5

in diameter &

TENDON YIELD STRENGTH


EFFECTIVE PRESTRESS AFTER ALL LOSSES

2
0.153 in area )

fpy =

243

ksi

fe =

174

ksi

THE CONCRETE DESIGN IS ADEQUATE.

DESIGN SUMMARY
FOOTING 61 ft DIA x 48 in THK. w/ # 10 @ 14" o.c. EACH WAY, AT TOP & BOT.
CONCRETE BIN 12 in THK. w/ # 8 @ 12 in o.c.DOWEL / VERT. BARS AT AT EACH FACE
BIN HORIZONTAL # 6 @ 12 in o.c. AT EACH FACE, AND (11) - STANDS @ 24 in o.c. (THE SECTION UNCRACKED.)

ANALYSIS
DETERMINE LATERAL LOADS
0.10 W , ASD (ASCE 7-05 15.4.1.2)

F = Max (0.8 S 1 I / R , 0.03) W / 1.4 =


Fcap =

0.10 W cap = 18.96 kips, at top

Fbin & wall =


Where

0.10

(W cap + W wall) =

S1 =

0.55

(from soil report, ASCE 7-05, 11.4.1)

783.78 kips, at 2/3 H

I =

1.00

(ASCE 7-05 15.4.1.1)

R =

(ASCE 7-05 Table 15.4-2)

W wall = 1718.1 kips


V=
M=

802.73 kips, total shear at top of footing


81221 ft-kips, total moment at top of footing

COMBINED LOADS AT TOP FOOTING (IBC 1605.3.2 & ACI 318-08 9.2.1)
CASE 1:
DL + LL
P
=
7662 kips
M
=
0
ft-kips
e
=
0.0 ft, fr cl ftg
CASE 2:
DL + LL + E / 1.4
P
=
7662 kips
M
=
81221 ft-kips
e
=
10.6 ft, fr cl ftg
CASE 3:
0.9 DL + E / 1.4
P
=
5350 kips
M
=
63222 ft-kips
e
=
11.8 ft, fr cl ftg

1.2 DL + 1.6 LL

1.2 DL + 1.0 LL + 1.0 E

0.9 DL + 1.0 E

Pu
Mu
eu
Pu
Mu
eu
Pu
Mu
eu

=
=
=
=
=
=
=
=
=

11500
0
0.0
8042
113710
14.1
5350
88511
16.5

kips
ft-kips
ft, fr cl ftg
kips
ft-kips
ft, fr cl ftg
kips
ft-kips
ft, fr cl ftg

(cont'd)
CHECK OVERTURNING FACTOR AT FOOTING EDGE BOTTOM (IBC 09 1605.2.1, 1808.3.1, & ASCE 7-05 12.13.4)
MR / MO =

3.4
M+VT =

Where MO =
W ftg =

>

1.5
84432

(0.15 kcf) T D2 / 4 =

[Satisfactory]
MR =

k-ft ,

(W) 0.5 D =

287186 k-ft

1753.5 kips, footing weight.

CHECK SOIL BEARING CAPACITY (ACI 318-08 SEC.15.2.2)


s =

0.11

kcf, soil weight

Service Loads
P
e

CASE 1
7662.5
0

CASE 2
7662.5
10.6

CASE 3
5350
11.817

Pftg - Psoil
P
e

1110.5
8773
0

1110.5
8773
9.2581

999.48
6349.4
9.9572

qmin
x

3.0019

0
@ 9.15 ft from edge

0
@ 9.15 ft from edge

ksf

qmax

3.0019

6.8882

5.2453

ksf

qallowable

5.5

7.3333

7.3333

ksf

k
ft (from center of footing)
k, (footing increasing)
k, (net loads)
ft

[Satisfactory]
CHECK ENTIRE FLEXURE & SHEAR OF FOOTING
(ACI 318-08 SEC.15.4.2, 10.2, 10.3.5, 10.5.4, 7.12.2, 12.2, 12.5, 15.5.2, 11.1.3.1, & 11.2)

MIN = MIN 0.0018


0.85 f c 1 1
'

T
4

,
d
3

MAX =

0.85 1 f c'
f y

u
u +t

Mu
0.383b d 2 f c'

fy

FACTORED SOIL PRESSURE


Factored Loads
CASE 1
Pu
eu
(0.15 T) A
Pu
eu
qu, min
x
qu, max

CASE 2

CASE 3

11500

8042.3

5350

0
2104.2

14.139
2104.2

16.544
1578.1

ft
k, (factored footingloads)

13604

10146

6928.1

11.207

12.776

ft

4.6551

0
@ 12.20 ft from edge

0
@ 15.25 ft from edge

ksf

4.66

9.22

7.10

ksf

FOOTING MOMENT & SHEAR FOR CASE 1


Section
0
L Edge

1/8 d

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

19.25
56.70

23.00
59.13

26.75
60.54

30.50
61.00

34.25
60.54

38.00
59.13

41.75
56.70

45.50
53.11

61.00
0.00

16.27

16.27

16.27

16.27

0.00

66657

97109 132805 172505 350760

Xu (ft, dist. from left of footing)


Tangent (ft)

0
0.00

15.50
53.11

qu,tank (ksf)

0.00

16.27

16.27

16.27

16.27

16.27

Mu,tank (ft-k)

3426.1

10857

23531

42067

Vu,tank (k)

914

1,982

3,380

6,557

8,121

9,519

qu,ftg (ksf)

0.72

0.72

0.72

0.72

0.72

0.72

0.72

0.72

Mu,ftg (ft-k)

3,952

6,095

8,733

10,587 11,500 11,500


0.72

0.72

0.72

11,885 15,565 19,776 24,514 29,767 35,515 64,177

Vu,ftg (k)

255

572

703

841

1,123

1,264

1,401

1,533

1,849

2,104

qu,soil (ksf)

-4.66

-4.66

-4.66

-4.66

-4.66

-4.66

-4.66

-4.66

-4.66

-4.66

-4.66

Mu,soil (ft-k)

-25551 -39409 -56461 -76843 -100634 -127860 -158495 -192460 -229618 -414937

Vu,soil (k)

-1,648

Mu (ft-k)

-21599 -29888 -36872 -41427 -43002 -41427 -36872 -29888 -21599

-3,696

Vu (kips)

-1,393

-2,210

-4,547

-1,862

-5,435

-1,215

-7,260

420

-8,169

1,215

-9,057

1,862

-9,909 -11,956 -13,604

2,210

1,393

(cont'd)
FOOTING MOMENT & SHEAR FOR CASE 2
0
L Edge
Section
Xu (ft, dist. from left of footing)
Tangent (ft)

0
0.00

15.50
53.11

qu,tank (ksf)

0.00

-33.59

Mu,tank (ft-k)

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

23.00
59.13

26.75
60.54

30.50
61.00

34.25
60.54

38.00
59.13

41.75
56.70

45.50
53.11

61.00
0.00

70.58

81.83

93.07

104.31 115.55 126.79 138.03

56.34

0.00

-526.47 240.15 2969.5 8194.6

16309

27522

41776

58559 131579

Vu,tank (k)

-240

349

1,242

3,694

5,105

6,489

7,640

8,042

8,042

qu,ftg (ksf)

0.72

0.72

0.72

0.72

0.72

0.72

0.72

0.72

0.72

0.72

0.72

Mu,ftg (ft-k)

3,952

6,095

8,733

Vu,ftg (k)

255

572

703

841

1,123

1,264

1,401

1,533

1,849

2,104

-1.33

-2.04

-2.75

-3.46

-4.16

-4.87

-5.58

-6.29

-9.22

11,885 15,565 19,776 24,514 29,767 35,515 64,177

qu,soil (ksf)

0.00

-0.62

Mu,soil (ft-k)

Vu,soil (k)

-363

-686

-1,202

Mu (ft-k)

3952

4206

5037

6410

Vu (kips)

255

-31

366

881

-1362.8 -3936.4 -8444.4 -15621 -26178 -40780 -60002 -84300 -195757

FOOTING MOMENT & SHEAR FOR CASE 3


Section
0
L Edge
Xu (ft, dist. from left of footing)
Tangent (ft)

0
0.00

15.50
53.11

qu,tank (ksf)

0.00

-27.43

Mu,tank (ft-k)

-2,815

-3,894

-5,126

-6,479 -10,146 -10,146

8139

9906

11256

11541

9774

2,001

2,474

2,764

2,693

-255

1/8 d

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

19.25
56.70

23.00
59.13

26.75
60.54

30.50
61.00

34.25
60.54

38.00
59.13

41.75
56.70

45.50
53.11

61.00
0.00

53.65

62.41

71.16

79.91

88.66

97.41

106.16

42.57

0.00

-374.39 107.08 1891.9 5338.2

10711

18155

27633

38804

74662

Vu,tank (k)

-170

219

813

2,446

3,389

4,315

5,085

5,350

5,350

qu,ftg (ksf)

0.54

0.54

0.54

0.54

0.54

0.54

0.54

0.54

0.54

0.54

0.54

Mu,ftg (ft-k)

2,964

4,572

6,550

8,914

Vu,ftg (k)

191

429

527

630

-0.62

-1.20

-1.78

-84.591 -732.1

-2517

-6029.8 -11852 -20528 -32544 -48289 -122795

11,674 14,832 18,386 22,326 26,636 48,133


842

948

1,051

1,149

1,387

1,578

-2.37

-2.95

-3.53

-4.11

-4.69

-7.10

qu,soil (ksf)

0.00

-0.04

Mu,soil (ft-k)

Vu,soil (k)

-23

-173

-476

-1,552

-2,314

-3,204

-4,199

-6,928

-6,928

Mu (ft-k)

2964

4113

5925

8289

10982

13692

16012

17414

17151

Vu (kips)

191

236

574

967

1,736

2,022

2,161

2,036

-191

FOOTING MOMENT & SHEAR SUMMARY


0
Section
Xu (ft, dist. from left of footing)
Tangent (ft)
Case Mu, (ft-k / ft)
Uniform Loads

1/8 d
19.25
56.70

Vu, (k / ft)

Case Mu, (ft-k / ft)


2

Vu, (k / ft)

Case Mu, (ft-k / ft)


3

Vu, (k / ft)

L Edge

1/8 d

2/8 d

3/8 d

Center

5/8 d

6/8 d

7/8 d

R Edge

0
0.00

15.50
53.11

19.25
56.70

23.00
59.13

26.75
60.54

30.50
61.00

34.25
60.54

38.00
59.13

41.75
56.70

45.50
53.11

61.00
0.00

0.0

-406.7

-527.1

-623.6

-684.3

-705.0

-684.3

-623.6

-527.1

-406.7

0.0

0.0

-26.2

-39.0

-31.5

-20.1

6.9

20.1

31.5

39.0

26.2

0.0

0.0

74.4

74.2

85.2

105.9

133.4

163.6

190.4

203.6

184.0

0.0

0.0

4.8

-0.6

6.2

14.6

32.8

40.9

46.7

47.5

-4.8

0.0

0.0

55.8

72.5

100.2

136.9

180.0

226.2

270.8

307.1

322.9

0.0

0.0

3.6

4.2

9.7

16.0

28.5

33.4

36.6

35.9

-3.6

0.0

min

reqD

max

smax

provD

CHECK FLEXURE
Location

Mu,max

d (in)

Top Slab
Bottom Slab

322.9 ft-k / ft
-705.0 ft-k / ft

45.37
44.37

0.0019 0.0030 0.0243 no limit 0.0020


0.0019 0.0070 0.0243
18
0.0020

[Satisfactory]

CHECK FLEXURE SHEAR


Vc = 2 b d (fc')0.5

Vu,max
47.5

k / ft

56

check Vu < Vc

[Satisfactory]

CHECK BIN VERTICAL FLEXURAL & AXIAL CAPACITY


o =

2 0.85 f

'
C

, E c = 57

Ec

'
C

c
c

o
o

0.85 f

'
C

for c o

f y ,

for s y
for s > y

0.85 f

sE s ,

, E s = 29000ksi

'
C

for 0 < c < o

40000
35000
30000

AT AXIAL LOAD ONLY

34748

AT MAXIMUM LOAD

34748

69734

AT 0 % TENSION

28765

133851

AT 25 % TENSION

24488

175599

20000

AT 50 % TENSION

21920

191058

15000

AT t = 0.002

18587

201070

AT BALANCED CONDITION

17229

188611

AT t = 0.005

17125

242597

40448

25000

Pn (k)

(cont'd)
Mn (ft-kips)

Pn (kips)

10000
5000

AT FLEXURE ONLY

0
0

50000

100000

150000

200000

250000

300000

Pu

Mu

Mn (ft-k)

169

34748 kips., (at max axial load, ACI 318-08, Sec. 10.3.6.1)

>

(ACI 318-08, Sec.9.3.2.2)

2
13119 in .

Ag =
a = Cb 1

0.70

in2.

Ast =

0.65 + ( t - 0.002 ) (250 / 3), for Ties


Cb = d c / (c + s) =
d

Pu

[Satisfactory]

2
47.40 in .

in (at balanced strain condition, ACI 10.3.2)

0.7 + ( t - 0.002 ) (200 / 3), for Spiral

where

kips

(from load combinations)

Pmax =0.85 [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

8042

113710 ft-kips, max at bottom

212

0.656

in

357.38 in, (ACI 7.7.1)

Mn = 0.9 n =40448

(ACI 318-08, Fig. R9.3.2)

t =

0.002069

1 =

0.8

c =

0.003

( ACI 318-08, Sec. 10.2.7.3 )

ft-kips @ Pn = 0, (ACI 318-08, Sec. 9.3.2) ,& et,min = 0.004, (ACI 318-08, Sec. 10.3.5)

Mn = 135380 ft-kips @ Pu =

8042

>

kips

max

0.08

min

0.004 (ACI 318-08, Section 10.5.1 or 10.9.1)

provd

(ACI 318-08, Section 10.9)

Mu

[Satisfactory]

0.004
[Satisfactory]

CHECK BIN HORIZONTAL SHEAR CAPACITY

Vn = (Vc) =

1235

kips, (ACI 318-08 Sec. 11.1.1)

>

where

Vu = 1.4 V =
1123.8 kips, max at bottom
(ACI 318-08 Sec. 9.3.2.3)
2
11640 in .

[Satisfactory]

0.75

A0 =

Vc = 2 (fc')0.5A0 =

1646.2 kips, (ACI 318-08 Sec. 11.2.1)

CHECK DOWEL DEVELOPMENT

L dh = MAX

requird 0.02 ed b f y
, 8d b , 6 in =
provided f 'c

12 db =

12

in, (ACI 318-08 12.5.2)

[Satisfactory]
where Bar size
db

=
required / provided

8
1

60

ksi
ksi

fy

f'c

1.0

1.0

c
Ktr

=
=
=
=
(c + Ktr ) / db =

in

( A s,reqd / A s,provd , ACI 318-08, 12.2.5)

(1.2 for epoxy-coated, ACI 318-08 12.2.4)

1.0 (0.8 for # 6 or smaller, 1.0 for other)


1.0
3.5 in, min(d' , 0.5s), (ACI 318-08, 12.2.4)
(Atr fyt / 1500 s n) =
0
(ACI 318-08, 12.2.3)
2.5
0.7

< 2.5 , (ACI 318-08, 12.2.3)


(#11 or smaller, cover > 2.5" & side >2.0", ACI 318-08 12.5.3)

CHECK BIN LOCAL SHEAR STRESS ON A SQUARE FOOT

vn = (vc) =

77.28 kips, (ACI 318-08 Sec. 11.1.1)

>

where =
A0

vu = 1.4 p =
13.10 kips
(ACI 318-08 Sec. 9.3.2.3)
2
= 4 x (1'-0") x (0.5 x T) =
288 in .

vc =
p=

0.75

4 (fc')0.5A0 =
103.0 kips, (ACI 318-08 Sec. 11.11)
9360 psf, (the max perpendicular wall pressure)

[Satisfactory]

<

44

in

(cont'd)

CHECK BIN WALL TENSION STRESS & CRACKING AT HORIZONTAL SERVICE INSIDE PRESSURE
p=
T=

9360
940

psf, (the max perpendicular wall pressure)


lbs / in2 , by pure math method
2
2
T fe = -1017 lbs / in , effective prestressing
>
0.8 ( 0.6 fc') =
-2400 lbs / in
[Satisfactory]
(ACI 318 18.4.1)
2
2
T + T fe = -77 lbs / in
<
7.5 (fc')0.5 =
530 lbs / in , (ACI 318 Eq. 9-10 & 18.3.3)
[Uncracked]

CHECK BIN WALL HORIZONTAL TENSION CAPACITY


1.6 T =

1504

lbs / in2

Where =

0.90

(fy As / Ac + fpy Aps / Apc) =


[Satisfactory]
, (ACI 318-08 R9.3.2)

<

As / Ac =

0.0061

Aps / Apc =

0.0058

1608

lbs / in2

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Super Composite Column Design Based on AISC 360-05 & ACI 318-08
INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc'

ksi

STEEL YIELD STRESS


COLUMN EFFECTIVE LENGTH

fy
KL

=
=

50
240

ksi
ft

CONCRETE SECTION SIZE

Cx

240

in

Cy

125

in

Dx

192

in

Dy

100

in

t1

in

t2

1.5

in

STEEL SECTION SIZE

t3

in

Dw

75

in

Pu

= 50000 k

FACTORED AXIAL LOAD


FACTORED MOMENT

FACTORED SHEAR LOAD

Mu,x

= 310000 ft-k

Mu,y

= 100000 ft-k

Vu,x

1800 k

Vu,y

3200 k

THE COLUMN DESIGN IS ADEQUATE.

ANALYSIS
80000
60000

40000
20000

Pn (k)

0
0

100000

200000

300000

400000

500000

-20000
-40000
-60000
-80000

Mn (ft-k)

0.75
0.75
0.75
0.78
0.82
0.86
0.9
0.9
0.9

Capacity Drawings
AT AXIAL LOAD ONLY
AT MAXIMUM LOAD
AT AXIAL LOAD 45615 k
AT AXIAL LOAD 35923 k
AT AXIAL LOAD 26276 k
AT AXIAL LOAD 14501 k
AT STEEL STRAIN 0.005
AT AXIAL LOAD -28982 k
AT PURE TENSION

Pn (k)
56495
56495
45615
35923
26276
14501
715
-28982
-58680

Mn (ft-k)
0
362678
383081
407207
417700
413791
392128
232902
0

o =

2 0.85 f

'
C

Ec

, E c = 57

c
c

o
o

56495

>

'
C

where

0.75

Ac

28696

3 2 2 3 0 .8 3

0.85 f
f

'
C

sEs ,
f y ,

for c o
for s t
for s > t
,

1 6 9 3 3 .1 1

As

1304

[Satisfactory]
(AISC 360-05 I2.1b & ACI 318-08 9.3.2.2)
in2
2

in

4 6 1 9 1 .3 6

kips, (AISC 360-05 I2-2 & I2-3)

Pu

, E s = 29000ksi

'
C

6 0 8 2 0 .3 9

0.85 f

CHECK FLEXURAL & AXIAL CAPACITY

Pmax = c Pn =

Ic

37543603

in4

Is

1518897

in4

for 0 < c < o

(cont'd)

Balanced :

C1

0.187

, (AISC 360-05 I2-7)

Pe

86072

kips, (AISC 360-05 I2-5)

Cb = d
d

374858

72334735452

Po

187158

(AISC 360-05 I2.1b & ACI 318-08 Fig. R9.3.2)

0.75

c / (c + s )

151.5 in

238.6 in, (ACI 7.7.1)

t =

0.0017

D =

266.8

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.9
0.75

Critical Points
AT AXIAL LOAD ONLY
AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT STEEL STRAIN 0.002
AT BALANCED CONDITION
AT STEEL STRAIN 0.005
AT FLEXURE ONLY

Mn =

E Ieff

ft-kips @ Pu =

50000 kips

Mu =

max

0.08 (ACI 318-08 10.9)

min

0.01 (AISC 360-05 I2.1a & ACI 318-08 10.9)

kips, (AISC 360-05 I2-4)

c =

0.003

in

Pn (k)
56495
56495
95998
81038
67975
39686
45661
715
0

>

ksi-in4, (AISC 360-05 I2-6)

Mn (ft-k)
0
362678
240093
298887
336762
390588
383006
392128
387404

325730 ft-kips

[Satisfactory]

provd

0.043
[Satisfactory]

CHECK SHEAR CAPACITY (AISC I2.1d & ACI 318-08 11.1 & 11.2)

Vnx = (Vcx)

>

Vux

(ACI 318-08 11.1.1)

v Vny = v (Vny)

>

Vuy

(AISC 360-05 G2.1)

where

=
v =

x
y

[Satisfactory]

0.75 (ACI 318-08 9.3.2.3)


1.00 (AISC 360-05 G2.1)
d

A0

216
100

27000

Aw

Vc =

2 (fc')0.5A0

Vn = 0.6 fy Aw Cv

3818.4
550

16500.0

Vn
2864
16500

Note:
1.
The minimum Stud Shear Connectors (not shown on this spreadsheet) are 3/4" @ 12" O.C. in both directions of vertical and horizontal
around built-up structural steel shape. (AISC 360-05 I2.1g)
2.

The column shall be reinforced, not shown on this spreadsheet, with continuous longitudinal bars (
sr = 0.004 min.), and lateral ties or spirals
at least 0.009 in2 per in. (AISC 360-05 I2.1a)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Anchorage Design, with Circular Base Plate, Based on ACI 318-11 & AISC 360-10
INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc' =

SPECIFIED STRENGTH OF ANCHOR

futa =

65

ksi

BASE PLATE YIELD STRESS

fy =

36

ksi

ksi

CRITICAL BASE PLATE CANTILEVER

m=

3.3

in

BASE PLATE THICKNESS

t=

1.75

in

FACTORED AXIAL LOAD

Pu =

kips

FACTORED SHEAR LOAD

Vu =

kips, ( 0 if shear lug used.)

38

ft-kips

Mu =

FACTORED MOMENT
SEISMIC LOAD ? (ASCE 14.2.2.17)

== >

Yes

EFFECTIVE EMBEDMENT DEPTH

hef =

ANCHOR DIAMETER

d=

0.75

in

RADIUS ANCHOR LOCATION

R=

in

ANCHOR NUMBERS

n=

28

in

THE PLATE & ANCHORS DESIGN IS ADEQUATE.


DEVELOPED VERTICAL REBAR SIZE

ANALYSIS
DETERMINE MAX ANCHOR FORCES WITHOUT CONCTERE COMPRESSION CAPCAITY CONSIDERED
L= 2SR=
50.27
in
T = Pu / A - Mu R / I =
2
A = n S d /4 =

3.09

I = 0.5 $ R = 98.96

in2

Nua,2 = -T A / n =

in4

Nua,1 =

Nua = Max( Nua,1 , Nua,2 ) =

16.28

kips / bolt

Vua = 1.5 (Vu / n) =

1.29

kips / bolt

15.86

-35.89

kips / in2

kips / bolt, Tension

16.28

kips / bolt, (The tensile strength, ASCE 14.2.2.17)

16.28

kips

CHECK GOVERNING ANCHOR TENSILE STRENGTH (ACI 318, D.5.1.2)

=
where :

0.75

Ase,N

0.334

16.28
x
in

kips
1

Nua =

0.75

[Satisfactory]

, (ACI 318-11 D.4.4 & D.3.3.4.4)

CHECK GOVERNING ANCHOR SHEAR STRENGTH (ACI 318, D.6.1.2b)

where :

8.47

0.65

k
1

>

Vua =

0.65

1.29

kips

[Satisfactory]

(for built-up grout pads, first factor shall be multiplied by 0.8, ACI 318 D.6.1.3)
CHECK TENSION AND SHEAR INTERACTION OF GOVERNING ANCHORS : (ACI 318, D.7)
Since

Nua,2

<

INn

and

Vua,2

<

IVn

the full tension design strength is permitted.

The interaction equation may be used


1.13

<

1.2

[Satisfactory]

CHECK BASE PLATE THICKNESS (AISC Guide - 1, Eq. 3.3.14a)


fp =

4.42

ksi, the max possible concrete compression stress.


(ACI 318-11, 10.14.1 & 9.3.2.4, or AISC Guide - 1)
1.73

in

<

t=

1.75

in

[Satisfactory]

(cont'd)
CHECK SPLICE LENGTH OF TENSION ANCHOR WITH REBAR
32 db =

L s = 1.3 L d =

24

in, (ACI 318-11, 12.15.1)

<
25 db =

18

hef - 2" =

26

in

in

(ACI 318-11, 12.2.3)

where

U required / U provided

1.000

( A s,reqd / A s,provd , if not apply input zero, ACI 318-11, 12.2.5)

db

0.75

fy

65

ksi

\t

1.0

(1.3 for horizontal bar over 12" concrete, ACI 318-11 12.2.4)

\e

1.0

(1.2 for epoxy-coated, ACI 318-11 12.2.4)

\s

0.8

(0.8 for # 6 or smaller, 1.0 for other)

1.0

(0.75 for light weight, ACI 318-11, 12.2.4)

cb

1.9

in, (ACI 318-11, 12.2.4)

Ktr

(cb + Ktr ) / db =

in, anchor governing

(Atr fyt / 1500 s n) =


2.5

(ACI 318-11, 12.2.3)

< 2.5 , (ACI 318-11, 12.2.3)

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Composite Beam/Collector Design, without Metal Deck, Based on AISC 360-10 & ACI 318-11

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


BEAM/COLLECTOR SECTION

W21X44

STEEL YIELD STRESS

Fy =

50

ksi

CONCRETE STRENGTH

fc' =

ksi

CONCRETE COVER

Cc =

t0 =

4.25

in, 0.75" min., (ACI 318-11 7.7)


in, 2.20 Min.
L=
B =

BEAM/COLLECTOR SPAN
SPACING (Tributary Width)
STRONG AXIS POSITIVE MOMENT, LRFD

30
ft
28
ft, o.c.
480
Mu =

ft-kips, SD level

Vu =

150

kips, SD level

100

kips, SD level, at center of W21X44

SHEAR LOAD, LRFD


COLLOCTOR AXIAL LOAD, LRFD
SHEAR STUD DIA. (1/2, 5/8, 3/4)
STUDS SPACING
2

Pu =
I =
rows @

3/4
12

THE DESIGN IS ADEQUATE.

in
in o.c.

ANALYSIS
DETERMINE CAMBER/SHORING ON NON-COMPOSITE
kips / ft, floor system self weight, to W21X44, on non-composite
w=
2.497
' = 5wL 4 / 384 EI =
1.86
in, deflection of W21X44
<
L / 180
=
2.00
in
[Satisfactory]
1.40 in
0.75 ' =
Camber =
CHECK FLEXURAL & AXIAL CAPACITY (AISC 360-10, I3, ACI 318-11 Chapter 10 & 21)

Ho

2 0.85 f 'C

Ec

, Ec

57 f C' , E s

29000ksi




0.85 f C' 2 H c  H c , for 0  H c  H o

H o H o

'

0.85 f C , for H c t H o

H s E s , for H s d H t
f
, for H s ! H t

y
2

fC
H

Pn
2500

2000

1500

1000

b = MIN (L / 4 , B) =
90
in, (AISC 360-10 I3.1a)
I =
, (AISC 360-10 I3)
0.9
Mn @ Pu/ I =
597.5
ft-kips

IMn =

537.7

>
500

ft-kips
M u + 0.5C c P u =

484.2

[Satisfactory]

0
0

500

1000

1500

2000

Mn

-500

Solid Line - Tension Controlled


Dash Line - Compression Controlled
CHECK SHEAR CAPACITY (AISC 360-10, G2)
IVn =
195.6
kips

>

Vu =

150.0

kips

[Satisfactory]

DETERMINE COMPOSITE PROPERTIES FOR ELASTIC DESIGN


n

E
Ec

A ctr = b t 0 / n =

6.76
56.5

, (ACI 318-11 8.5.1)


2

in

A
13

d
20.7

Ix
843

Sx
81.6

Zx
95.4

ft-kips

yb

Actr d  0.5t 0  0.5 Ad


Actr  A

I tr

I x  A y b 0.5 d 

S tr

I tr

(cont'd)
20.5

2
Actr t 02
 Actr 0.5t 0  d  y b
12

126

d  t0 

yb

577

:b =

1.67

in , referred to concrete top.

Mn / :b = Zx Fy / :b =

238.0

650

S eff = Min[ M max / (0.66 F y ) , S tr ] =

116

kips, (AISC 360-10 C-I3.1)


3
in , referred to steel bottom.

406.54

kips, (AISC 360-10 C-I3-5)

MAX

S eff  S s 2

S tr  S s , 0.25 C f

Q n = MIN [ 0.5 A sc (f c ' E c ) 0.5 , R g R p A sc F u ] =


where

wc =

150
0.44

16.34

kips, (AISC 360-10 I3.2d)

4286.8

V'

[Satisfactory]

ksi

in

Fu =

58

Rg =

0.85

(AISC 360-10 Table I3.2b)

Rp =

0.75

(AISC 360-10 Table I3.2b)

6Qn = Qn Nr X1 / s =

<== Shear Studs Required

pcf

E c = w c 1.5 33 (f c ') 0.5 =


A sc =

ft-kips

(AISC 360-10 F1 & F2-1)

C f = MIN ( 0.85 f c ' A c , F y A s ) =

V'

in

in , referred to steel bottom.

CHECK SHEAR CONNECTOR CAPACITY (ASD)


M max =
320.0 ft-kips
>
where

2573

yb

I tr

St

in, (elastic neutral axis to bottom)

ksi

490.05

kips

>

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Multi-Story Tilt-Up Wall Design Based on ACI 318-11


DESIGN CRITERIA
1. Multi-story tilt-up wall design may be governed by erection bending forces. To cut tall wall to two different casting panels (i. e. 4 story + 2 story )
can reduce the maximum section forces, be constructed on a very tight site, and reduce upper panel thickness.
2. Since it is difficult to design multi-story tilt-up wall tension-controlled (ACI 318-11 14.8.2.3) only, this software does NOT use the method of
Alternative Design of Slender Walls (ACI 318-11 14.8), so there are no P-' effects have to be applied (ACI 318-11 14.8.4).

INPUT DATA & DESIGN SUMMARY


FACTORED MAX OUT-OF-PLANE SECTION MOMENT (from erection, wind, and/or seismic loads, the max value of w max L 2 /8 may be input).
Mu
=
12
ft-kips / ft
FACTORED AXIAL LOAD (con-currently at the same section with Mu).
Pu

35

kips / ft

FACTORED SHEAR LOAD

Vu

7.2

kips / ft

CONCRETE STRENGTH

fc'

ksi

REBAR YIELD STRESS

fy

60

ksi

THICKNESS OF WALL

10

in

WALL REINFORCING (As)


As LOCATION (1=at middle, 2=at each face)

18

in o.c.

at each face

[THE WALL DESIGN IS ADEQUATE.]

ANALYSIS
CHECK AXIAL & FLEXURE CAPACITY
UProvD = 0.00224

<

UMAX =

0.0400 (tension face only, ACI 318-11 10.3.5 or 10.9.1)

>

UMIN =

0.0008 (tension face only, ACI 318-11 10.5.1, 10.5.3 or 14.3.2)

[Satisfactory]

200.0

I Pn

I Mn

180.0

AT AXIAL LOAD ONLY

171.5

0.0

160.0

AT MAXIMUM LOAD

171.5

8.0

140.0

AT MIDDLE

115.5

19.3
22.5

ATHt = 0.002

59.5

AT BALANCED

58.1

22.6

ATHt = 0.005

42.7

25.4

80.0

AT FLEXURE ONLY

0.0

7.0

60.0

(Note: For middle reforcing the max I M n is at c

120.0
I Pn (k)

100.0

40.0

equal to 0.5 t / E 1 , not at balanced condition.)

20.0
[Satisfactory]

0.0
0.0

5.0

10.0

15.0

20.0

25.0

30.0

I Mn (ft-k)
CHECK SHEAR CAPACITY (ACI 318-11 SEC.15.5.2, 11.1.3.1, & 11.2)

IV n

2I bd

'

fc

7.58 kips / ft

>

Vu

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Composite Moment Connection Design Based on ACI 318-11


INPUT DATA & DESIGN SUMMARY
BEAM SHAPE (Tube, Pipe, or WF) & SIZE

W24X192

< ==

CONCRETE STRENGTH

fc' =

ksi

FACTORED SHEAR LOAD

Vu =

205

kips

FACTORED MOMENT

Mu =

750

ft-kips

FACTORED VERTICAL LOAD (negative for uplift)

Pu =

691

kips

D=

48

in

EMBEDMENT DEPTH

W Shape

bf

25.5

56.3

13.0

THE MOMENT CONNECTION DESIGN IS ADEQUATE.


( Avf =

in2 , Required Area of Shear Studs or Welded Reinforcement.

16.0

Side edge of concrete must be wider than "b f", and top/bottom concrete height
can fully developed vertical bars.)

ANALYSIS
CHECK FLEXURAL & SHEAR CAPACITY (ACI 318 Chapter 9 & 10)

700
600
500
I Vn (k)

400
300
200
100
0
0

500

1000

1500

2000

I Mn (ft-k)
I Mn =

ft-kips @ Vu =

1103

>

0u =

750

205

kips

ft-kips
[Satisfactory]

I Vn,max =

611.08

>
where

Vu =

kips, when C =

33.0 in

205

[Satisfactory]

ft-kips

I=
0.65
, (ACI 318 9.3.2.4)
Bearing factor = 2, (ACI 318 22.5.5)

b = effective bearing width = 95%


CHECK HORIZONTAL AXIAL CAPACITY
I Pn = End Bering + Friction =
where

1295.4

>

Pu =

691

186.6

kips, (ACI 318 22.5.5)

Friction = 0.75 MAX( 0.2fc' Ac , 800 Ac ) =

1108.8

kips, (ACI 318 11.7.5)

A=

56

Avf = Pu,Friction / (I fy P) =

kips

[Satisfactory]

in2, end bearing area

Ac = 0.5 (2d + 2bf ) D =


where

kips

End Bering = 0.65 (2) 0.85 f c' A =

16.0

1848

in2, (0.5 for concrete cracked)

in2 , Required Area of Shear Studs or Welded Reinforcement

I=
P =

0.75
0.70

, (ACI 318 9.3.2.3)


, (ACI 318 11.7.4.3)

fy =

60

ks

bf =

12.35

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Flexural & Axial Design for Custom Metric Bars Based on Linear Distribution of Strain
DESIGN CRITERIA
This design method is, based on linear distribution of strain of ACI 318-11, for custom metric bars, which can apply to Shear Wall, Beam,
and/or Column, including Metric System for different country codes.
INPUT DATA & DESIGN SUMMARY
REBAR YIELD STRESS

fy =

400

N/mm2 =

58

ksi

CONCRETE STRENGTH

f c' =

20

N/mm2 =

2.9

ksi

SECTION DEPTH
SECTION WIDTH

H=
b=

1300
300

50.7
11.7

in
in

mm
mm

=
=

SD LEVEL SECTION LOADS


Pu =

1250

kN

281.0

Mu =

400

kNm =

293.0

ft-kips

Vu =

520

kN

116.9

kips

kips, (axial force)

THE SECTION DESIGN IS ADEQUATE.

AXIAL REINFORCEMENT
bars (side faces)

- single bar area

130

mm2

- spacing

150

mm

(
2
bars (side faces)
TENSION REINFORCEMENT

- single bar area

0.20

in2

- spacing

5.9

in o.c.)

Layer

- each layer

bars

- single bar area

300

mm2

Layer

- each layer

bars

- single bar area

0.47

in2 )

SHEAR REINFORCEMENT
(

legs (side faces)

- single leg area

300

mm2

- spacing

150

mm

legs (side faces)

- single leg area

0.47

in2

- spacing

5.9

in o.c.)

ANALYSIS
CHECK FLEXURAL & AXIAL CAPACITY
5000

1200
1000

4000

800
3000
600
2000
400
1000
200
0
-200

200

400

600

800

1000

-100

-1000

100

-2000

300

400

500

600

700

-400

IMn (kNm)
Hc =

200

-200

0.003

IMn (ft-k)

, (ACI 318-11 10.2.3)

Pu =

I=

0.834

, (for Pu & Mu, ACI 318-11 9.3.2)

d=

1259

mm

49.6

1250

<

in

IPn =

Mu =

400.00

<

IMn =

kN
3920

= 281

kips

kN

= 881

kNm = 293.04
750.27

kips, (ACI 318-11 10.3.6.1)

ft-kips

kNm = 549.65

ft-kips, at Pu level.

cb =
755
mm = 29.7
in
(balance point between Tension Controlled and Compression Controlled.)

[Satisfactory]

CHECK SHEAR CAPACITY


Vu =
where

520
I =

kN =
116.9 kips
0.75
(ACI 318-11 9.3.2.3)

Vc =

2 (fc')0.5A0 =

Vs =

MIN (d f y Av / s , 4Vc) =

142

<
kN
568

I Vn = I (Vs + Vc) = 533


=

31.9
kN

kN =
119.8 kips
(ACI 318-11 11.1.1)

kips, (ACI 318-11 11.2.1)


=

127.8

kips, (ACI 318-11 11.4.7.2)

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Prestressed Concrete Girder Design for Bridge Structure Based on AASHTO 17th Edition & ACI 318-08
INPUT DATA & DESIGN SUMMARY
f 'c =

ksi

fy* = fy =

60

ksi

T=

42

fsu* = fpu =

270

ksi

B=

28

in

fpy =
12
8

243
#
#

ksi

12

C=
D=
E=
F=
G=
W=

8
72
10
7
5
8

in
in
in
in
in
in

0.5

in diameter &

0.153

DISTANCE TO CENTROID OF COMPRESSION

d' =

4.5

in

DISTANCE TO CENTROID OF PRESTRESSED

dp =

64

in

yt =

34.65

in

DISTANCE TO CENTROID OF TENSION

d=

68

in

yb =

37.35

in

GIRDER SPAN LENGTH

L=

80

ft

I=

762125

GIRDER SPACING

S=

ft, o.c.

St =

21995

in4
in3

CONCRETE DECK THICKNESS

t=

in

Sb =

20405

in3

CONCRETE STRENGTH
REBAR STRENGTH
TENDON TENSILE STRENGTH
TENDON YIELD STRENGTH
COMPRESSION REINF.
TENSION REINF.
SHEAR STIRRUP REINF.
2
legs, #
PRESTRESSING TENDONS
strands (each
36

SECTION DIMENSIONS

8
8
in o. c.

in

in2 area )

SECTION PROPERTIES
A=
1125
in2

TENDON FORCE IMMEDIATELY AFTER PRESTRESS TRANSFER


Pi =
TENDON FORCE AT SERVICE LOAD AFTER ALLOWANCE LOSSES
Pe =
MOMENT DUE TO SELF-WEIGHT
MOMENT DUE TO DEAD LOAD
MOMENT DUE TO LIVE LOAD

MG =
MD =
ML =

1042
1000
1354

FACTORED SHEAR FORCE

Vu =

250

FACTORED TORSIONAL MOMENT

Tu =

52

ft-k

SECTION LOCATION ( 0, 1 or 2 )
PRESTRESSING METHOD ( 0, 1 or 2 )
EXPOSURE ( 0 OR 1 )
THE DESIGN IS ADEQUATE.

e=

29.35

in

MIN. TOP FIBER STRESS

- Fti =

-0.581

ksi

MAX. BOT. FIBER STRESS

Fbi =

3.300

ksi

MAX. ALLOWABLE STRESS

Fsi =

189.000

ksi

f si

181.554

ksi

<

Fsi

[Satisfactory]

f ti = P i

1 e

+ MG =
A St
St

0.123

ksi

- Fti
>
[Satisfactory]

f bi = P i

1 e
+
MG =
A Sb
Sb

1.715

ksi

Fbi
<
[Satisfactory]

(As')reqd

2
=
0.000 in
(ACI 318-08 R18.4.1)

(As')provd
<
[Satisfactory]

CHECK SERVICEABILITY LOAD CONDITION


(AASHTO 9.15.1 & 9.15.2.2)

MIN. TOP FIBER STRESS


Fte = 0.6fc' =

3.600

ksi, for total loads

Fte, G+D = 0.4fc' =

2.400

ksi, for sustained loads only

Fte, 0.5(G+D)+L = 0.4fc' =


2.400
MAX. BOT. FIBER STRESS

ksi, for live + 50% sustained loads

-Fbe = -(0, 3, or 6)(fc')0.5 =


-0.465 ksi
MAX. ALLOWABLE STRESS
Fse = 0.8fy = 194.400 ksi, after all losses

f se

145.243

ksi

kips

800

kips

ft-k
ft-k
ft-k

at midspan
post-tensioned & bonded
mild exposure

Additional 4 #8 Longitudinal Reinforcement Required for Torsion

CHECK TRANSFER LOAD CONDITION (AASHTO 9.15.1 & 9.15.2.1)


PRESTRESSED ECCENTRICITY

0
2
0

1000

__

Fse
<
[Satisfactory]

Page 192 of 533


524

(Cont'd)

+
+
1 e

+ MG MD ML =
A St
S ct

f te = P e

f te,G + D = P e

1 e
+

+ MG MD =
A St
S ct

+
+
1 e
+
MG MD ML =
A Sb
S cb

Fte

<

0.100 ksi

0.5( M G + M D) + M L
1 e

+
=
A St
S ct

f te,0.5(G + D )+ L = 0.5P e

f be = P e

0.403 ksi

Fte, G+D

<

0.353

[Satisfactory]

kis

COMPOSITE SECTION PROPERTIES


in, (ACI 318-08 8.12.3)
b=
96
in2
Ac =
1893

[Satisfactory]

Fte, 0.5(G+D)+L

<

-Fbe

>

1 =

0.75

, (ACI 318-08 R10.2.7)

TENDON TYPE FACTOR


RATIO OF TENSION REINF.
RATIO OF COMPR. REINF.

p =
=
' =

0.280
0.002
0.003

, (ACI 318-08 18.7.2)


, (ACI 318-08 Chapter 2)
, (ACI 318-08 Chapter 2)

RATIO OF PRESTR. REINF.


INDEX OF TENSION REINF.
INDEX OF COMPR. REINF.

p =
=
' =

0.002
0.022
0.033

, (ACI 318-08 Chapter 2)


, (ACI 318-08 18.7.2)
, (ACI 318-08 18.7.2)

INDEX OF PRESTR. REINF.

p =

0.086

, (ACI 318-08 18.7.2)

in

53.03

in

Sct =

53691

in3

Scb =

27305

in3

c = 0.003

Fc
Parabolic

A ps f ps

, (AASHTO Eq. 3-10)

Asfy

STRESS IN BONDED TENDONS :

ps

= f

pu

p
1

pu
p '
fc

MIN

'

o =

, 0.17

dp

252.864

ksi

fC=

STRESS IN UNBOUNDED TENDONS :

f 'c
,f ,f
f ps = MIN f se + 10 +
100 p y

0.85 f c'
A s' f s'

FACTORED ULTIMATE MOMENT


Mu = ( D MD + L ML ) = 1.3 [ 1.0 ( MG + MD) + 1.67 ML]
= 5594.134 ft-k

4
1448000 in

[Satisfactory]

CHECK ULTIMATE LOAD CONDITION (AASHTO 9.15.1 & 9.17 ACI 318-08 18.7)
COMPRESSION ZONE FACTOR

26.97

Ic =

[Satisfactory]

0.369 ksi

yct =
ycb =

2 0.85 f

'
C

Ec
0.85 f C' 2

, E c = 57 f C' , E s = 29000ksi

c
o
o

, for 0 < c < o

0.85 f C' , for c o


se + 60

Not applicable

fc
, f y, f se + 30 =
300 p

Not applicable

s E s , for s t
fS=
f y , for s > t

'

ps

= MIN f se +10 +

s,max =
c=

0.0021
18.4

, (ACI 318-08 10.3.4 & 10.3.5)


in, by pure math method

Fc = 1612.817 kips

M n = A ps f

ps

( d p d c ) + As f y ( d d c ) + A's f y ( d c d ')

dc =

7964

ft-k

>

Mu

4.971

in

As 'fs' =

159.158

kips

As fy =

379.200

kips

[Satisfactory]

Aps fps = 1392.775 kips

1.2M cr = 1.2 S b P e

1
Ac

e
Sb

+ 7.5 f 'c M G

S cb
1 =
Sb

4632

Mn
[Satisfactory]
ft-k
<
(AASHTO 9.18.2 & ACI 318-08 18.8.2)

CHECK SHEAR CAPACITY (AASHTO 9.20, ACI 318-08 11.1 & 11.4)
d = MAX ( 0.8h , d p ) =

Vc =

MAX MIN
2b wd

V s = MIN

64.00

0.6 f 'c + 700 MIN 1 ,

f 'c , for

se < 0.4 f

f 'c = MIN 100 ,

in

V ud p

b wd , 5b wd

Mu

f 'c

, 2b wd

f 'c

( f c' )

, for

Av f yd
, 8b wd f 'c =
S

MIN ( 0.75d , 24 ) ,
MIN ( 0.375d , 12 ) ,

281.60

for V s 4b wd
for V s > 4b wd

Av (min) =

kips

'
c

Av ,requd = Av (min)

se

0.4 f

50b wS
MAX
,
fy

A ps f

pu

116.39

kips

V c

puS

80df

bw

'
c

12.00

, for f se 0.4 f

pu

0.164

pu

__
f

no shear re inf . requd , for case1: V u <


, for case 2 :

psi

pu

50b wS
, for f se < 0.4 f
fy

S max =

77.46

provd

in

V c
2

V u V c

=
2
MAX ( Av ,cal , Av (min) ) , for case 3 : V c V u (V S + V c )

unsatisfactory , for case 4 : (V S + V c ) V u

Page 193 of 533


524

0.523

in2

[Satisfactory], Case 3 applicable

in2

(Cont'd)

CHECK TORSIONAL CAPACITY (AASHTO 9.21, ACI 318-08 11.1 & 11.5)
Acp

576

in2

Pcp

160

in

fpc

1.389

ksi

Aoh

290

in2

Ph

145

in

At =
Tu
=
S 1.7 Aoh f yv cos ( 37.5 )

Tu

>

f c'

2
Acp

P cp

1+

pc

4 f c'

11.403

Thus, Torsional Reinf. Reqd.

0.013

A L = MAX

in2/in

f
At
Ph
S
f

yv

cot 2 ( 37.5 ) ,

yL

5 Acp f c'
f

yL

Ph

yv

yL

25b w
max At ,
S
f yv

3.19

Additional 4 #8 Longitudinal Reinforcement Required for Torsion

At
S

= MAX
Total Re qD

ft-kips

50b w
Av + 2 At
=
,
S
f yv

0.069

in2/in

<

At
S

0.073

in2/in

Pr ovD

[Satisfactory]

__
Page 194 of 533
524

in2

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Bridge Column Design Based on AASHTO 17th & ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc'

REBAR YIELD STRESS

fy

60

ksi

SECTION SIZE

Cx

120

in

End

12

in

Cy

48

in

Pu

FACTORED AXIAL LOAD


FACTORED MAGNIFIED MOMENT

ksi

8000 k

Mu,x

= 18000 ft-k

Mu,y

= 18000 ft-k

Vu,x

30

Vu,y =
COLUMN VERT. REINFORCEMENT
15 #
5
#
LATERAL REINF. OPTION (0=Spirals, 1=Ties)
LATERAL REINFORCEMENT
#
4 @
3
straight legs
#
4 @

20
18
18
1
12
12

k
at x dir.
at y dir.
Ties
in o.c.
in o.c.

FACTORED SHEAR LOAD

THE COLUMN DESIGN IS ADEQUATE.


(Total 40 # 18)

ANALYSIS
25000
20000

15000

Pn (k)
10000

5000
0
0

10000

20000

30000

40000

50000

Mn (ft-k)
Pn (k)
19147
19147
18160
15279
12730
8897
8731

AT AXIAL LOAD ONLY


AT MAXIMUM LOAD
AT 0 % TENSION
AT 25 % TENSION
AT 50 % TENSION
AT t = 0.002
AT BALANCED CONDITION
AT t = 0.005
AT FLEXURE ONLY

885
0

Mn (ft-k)
0
14042
16393
22182
25771
29007
29407

o =

45199
43623

2 0.85 f

0.85 f

0.85 f

'
C

Ec
'
C

, E c = 57

'
C

2
2 c c ,
o o

, E s = 29000ksi
for 0 < c < o

'
C

, for c o

s E s , for s t
=
f
, for s > t

CHECK FLEXURAL & AXIAL CAPACITY

Pmax =F [ 0.85 fc' (Ag - Ast) + fy Ast] =


where

19147 kips., (at max axial load, ACI 318-08, Sec. 10.3.6.2)

0.65 (ACI 318-08, Sec.9.3.2.2)

0.8

2
Ag = 6565 in

0.75 + ( t - 0.002 ) (50), for Spiral

0.65 + ( t - 0.002 ) (250 / 3), for Ties


where

Cb = d
d

Mn =

30878

c / (c + s)

0.656

68.8 in

116.3 in, (ACI 7.7.1)


ft-kips @ Pu =

>

8000 kips

max

0.08 (ACI 318-08, Section 10.9)

min

0.01 (ACI 318-08, Section 10.9)

Ast =

Pu
>
2
160.00 in

[Satisfactory]

(ACI 318-08, Fig. R9.3.2)

t =

0.0021

D =

119.4 in

Mu =

25456 ft-kips

provd

c =

0.003

Cover =

1.5

in, (AASHTO 8.22.1)

[Satisfactory]

0.024
[Satisfactory]

CHECK SHEAR CAPACITY (ACI 318-08 Sec. 11.1.1, 11.2.1, & 11.4.6.2)

Vn = (Vs + Vc)

(ACI 318-08 Sec. 11.1.1)

>
where

=
x
y

Vu

[Satisfactory]

0.75 (ACI 318-08 Sec. 9.3.2.3)


d
A0
140.9 5655
44.9 5655

smax

24

smin

Av
0.40
1.00

fy =

Vc = 2 (fc')0.5A0
799.8
799.8

(ACI 318-08, Section 7.10.5.2)

60

ksi

Vs = MIN (d fy Av / s , 4Vc)
281.7
224.4
sprovd

12

in
[Satisfactory]

Vn
811
768

PROJECT :
CLIENT :
JOB NO. :
DATE :
Magnified Moment Calculation for Bridge Circular Column Based on AASHTO 17th & ACI 318-08

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


EFFECTIVE LENGTH FACTOR

1.6

COLUMN UNSUPPORTED LENGTH

Lu

24

LARGER FACTORED MOMENT

M2

1800

ft-k

SMALLER FACTORED END MOMENT

M1

1000

ft-k, (positive if single curvature.)

CONCRETE STRENGTH

fc'

COLUMN DIMENSIONS

Cx

120

in

End

12

in

Cy

48

in

Pu

8000

SUMMATION FOR ALL VERTICAL LOADS IN THE STORY

Pu

8000

SUMMATION FOR ALL CRITICAL LOADS IN THE STORY

Pc

50000 k, (ACI Eq. 10-21)

FACTORED AXIAL LOAD

THE MAGNIFIED MOMENT:

Mu

2378.1 ft-k

, (ACI 10.10.6.3 or 10.10.7.1)


ft

ksi

, Sway

ANALYSIS
MAGNIFIED MOMENT - NONSWAY
2
in
Ag =
6565
Ig =
0.5

r = ( Ig / A )
k Lu / r =

in

17.0
0.5

0.4 E c I g

1+ d

Pc =

<

27.0388647

Ec = 57000 (fc')

EI =

1906740

in, ACI 10.11.2


34 - 12(M1 / M2) = 27.333 < = = Slenderness effect may be ignored. (AASHTO 8.16.5.2 or ACI Eq 10-7)

4030.5 ksi, ACI 8.5.1

0.4 E c I g
1 + 0.6

2EI =
2

= 0.25E c I g =

2
2E+09 k-in , ACI 10.10.6.1

89303 k, ACI Eq (10-14)

( k Lu )

M2,min = MAX[ M2 , Pu (0.6+0.03 (2 End + Cx)) ] =

3280

ft-k, ACI 10.10.6.5

Cm = MAX[ 0.6 + 0.4 (M1 / M2, min) , 0.4 ] =

0.722

, ACI Eq(10-16)

ns = MAX

Cm
, 1.0 =
Pu
0.75P c

Mu, ns = ns M2, min =

1.00

, ACI Eq (10-12)

>

3280.0 ft-k, ACI Eq (10-11)

1.05 M2 =

1890.0 ft-k

[Unsatisfactory]

,(ACI 10.10.5.1)

The column is sway. See calculation as follows.


MAGNIFIED MOMENT - SWAY
k Lu / r =

27.0388647

s = MIN MAX

16.90

M2s = M2 =

1800.0
5%

Mu, s = M2ns + s M2s =


Note:

22

1
, 1.0
Pu
0.75 P c

Lu / r =
M2ns =

>

<

< = = Slenderness effect must be considered. ACI Eq (10-6)

, 2.5 =

1.27

35 / [Pu / (fc' Ag)]0.5 =

, ACI Eq (10-21)

70.90

[Satisfactory]

ft-k, as given
M2s =

90.0

ft-k, assumed conservatively

2378.1 ft-k, ACI Eq (10-19)

For column subject to bending about both principal axis, the moment about each axis shall be magnified separately based
on the conditions corresponding to that axis.

__
Page 196 of 533
524

PROJECT :

PAGE :

CLIENT :
JOB NO. :

DESIGN BY :
REVIEW BY :

DATE :

Bridge Design for Prestressed Concrete Box Section Based on AASHTO 17th Edition & ACI 318-08
INPUT DATA & DESIGN SUMMARY
BRIDGE SPAN
SECTION DIMENSIONS
T=

120

L=

ft
SECTION PROPERTIES
2
A=
15529.0 in

280

in, within [B , 300"]

B=

240

in, within [200", 280"]

yt =

41.82

in

C=

110

in, within [80",180"]

yb =

54.18

in

D=

96

in, within [L/15 , L/25]

Tt =

12

in, within [8",18"] & >T/30

St =

Tb =

24

in, within [8", 24"] & >B/30

Sb =

W=

24

in, within [8", 24"] & >D/15

Tc =

24

in, within [14", 24"] & >C/12

Te =

I=

f 'c =

ksi

fy* = fy =

60

ksi

fsu* = fpu =

270

ksi

fpy =
TENDON YIELD STRENGTH
DISTANCE TO CENTROID OF COMPRESSION

243

ksi

TENDON TENSILE STRENGTH

472656

in

364825

in

in

CONCRETE STRENGTH
REBAR STRENGTH

19766329 in

DIST. TO CENTROID OF BOT. PRESTRESSED

d' =

in

dp,b =

84

in

dp,w =
DIST. TO CENTROID OF WEB. PRESTRESSED
76
in
80
in
DISTANCE TO CENTROID OF TENSION
d=
TOP COMPRESSION REINF.
2
8
12
#
@
2
8
12
BOTTOM TENSION REINF.
#
@
2
8
12
WEB HORIZONTAL REINF.
#
@
SHEAR STIRRUP REINF.
2
10
8
legs, #
@
BOTTOM PRESTRESSING TENDONS
strands (each
in diameter &
0.153
16
x
36
0.5
EACH WEB PRESTRESSING TENDONS
4
x
36
0.5
in diameter &
0.153
strands (each
Pi =
TOTAL TENDON FORCE IMMEDIATELY AFTER PRESTRESS TRANSFER
TOTAL TENDON FORCE AT SERVICE LOAD AFTER ALLOWANCE LOSSES
MOMENT DUE TO SELF-WEIGHT

MG =

MOMENT DUE TO DEAD LOAD

MD =

MOMENT DUE TO LIVE LOAD


SECTION LOCATION ( 0, 1 or 2 )
PRESTRESSING METHOD ( 0, 1 or 2 )
EXPOSURE ( 0 OR 1 )

ML =

0
2
0

2
in area )

in2 area )
23794.56 kips

Pe = 19035.648 kips

29116.963 ft-k
37500

in o. c.
in o. c.
in o. c.
in o. c.

ft-k

52500 ft-k
at midspan
post-tensioned & bonded
mild exposure

FACTORED VERT. SHEAR FORCE

Vu =

6886.735 k

FACTORED TORSIONAL MOMENT

Tu =

35868.412 ft-k

Mu,y =
FACTORED LATERAL BENDING MOMENT
(Seismic/Wind Horizontal Bending Load)

41320.41 ft-k

THE DESIGN IS ADEQUATE.

CHECK TRANSFER LOAD CONDITION (AASHTO 9.15.1 & 9.15.2.1)


ENTIRE SECTION PRESTRESSED ECCENTRICITY
e=
38.18
in
MIN. TOP FIBER STRESS
- Fti =
-0.581
MAX. BOT. FIBER STRESS

ksi

Fbi =
3.300
MAX. ALLOWABLE STRESS

ksi

Fsi =

f si

189.000

ksi

180.000

ksi

Fsi

<

[Satisfactory]

f ti = P i

1 e

+ MG =
A St
St

f bi = P i

1 e
+
MG =
A Sb
Sb

0.349

ksi

- Fti
>
[Satisfactory]
(As')reqd

3.065

ksi

Fbi
<
[Satisfactory]

(ACI 318-08 R18.4.1)

CHECK SERVICEABILITY LOAD CONDITION (AASHTO 9.15.1 & 9.15.2.2)


CONCRETE DECK THICKNESS
t=
4
in
(0 for non-composite)
COMPOSITE SECTION PROPERTIES
b=
500
in
2
Ac =
17529.0 in
yct =

40.82

in

ycb =

59.18

in

Ic =

23171159 in

4
3
3

Sct =

567642

in

Scb =

391537

in

__
Page 197 of 533
524

0.000

in2

<

(As')provd

[Satisfactory]

(Cont'd)
MIN. TOP FIBER STRESS

MAX. BOT. FIBER STRESS

Fte = 0.6fc' =

3.600

ksi, for total loads

Fte, G+D = 0.4fc' =

2.400

ksi, for sustained loads only

2.400

ksi, for live + 50% sustained loads

Fte, 0.5(G+D)+L = 0.4fc' =


f se

144.000

1 e
+

+ MG MD =
A St
S ct

f te,G + D = P e

f be = P e

Fse = 0.8fy = 194.400

2.206 ksi

<

Fte

[Satisfactory]

1.096 ksi

<

Fte, G+D

[Satisfactory]

kis

Fte, 0.5(G+D)+L
<
[Satisfactory]

>

-Fbe

0.5( M G + M D ) + M L
1 e

+
=
A St
S ct

f te,0.5(G + D )+ L = 0.5P e

-0.465

ksi

MAX. ALLOWABLE STRESS


ksi, after all losses

Fse
<
[Satisfactory]

ksi

1 e
+
+

+ MG MD ML =
A St
S ct

f te = P e

-Fbe = -(0, 3, or 6)(fc')

0.5

1 e
+
+
+
MG MD ML =
A Sb
S cb

1.658

-0.433 ksi

[Satisfactory]

CHECK ULTIMATE LOAD CONDITION (AASHTO 9.15.1 & 9.17 ACI 318-08 18.7)
FACTORED ULTIMATE MOMENT

c = 0.003

Mu,x = ( D MD + L ML ) = 1.3 [ 1.0 ( MG + MD) + 1.67 ML]

0.85 f c'

(AASHTO Eq. 3-10)

A s' f s'

= 200579.551 ft-k
Mu,y = 41320.410 ft-k

Fc
2

2 0.5

Mu = (Mu,x + Mu,y )
= 204791.437 ft-k

11.6

, (ACI 318-08 R10.2.7)

p =
0.280
RATIO OF TENSION REINF.
RATIO OF COMPR. REINF.

, (ACI 318-08 18.7.2)


=
0.001
' =
0.002

Asfy
, (ACI 318-08 Chapter 2)
, (ACI 318-08 Chapter 2)

RATIO OF PRESTR. REINF.


INDEX OF TENSION REINF.
INDEX OF COMPR. REINF.

p =
=
' =

0.006
0.013
0.016

, (ACI 318-08 Chapter 2)


, (ACI 318-08 18.7.2)
, (ACI 318-08 18.7.2)

INDEX OF PRESTR. REINF.


STRESS IN BONDED TENDONS :

p =

0.237

, (ACI 318-08 18.7.2)

ps = f

pu

A ps f ps

deg

COMPRESSION ZONE FACTOR


1 =
0.75
TENDON TYPE FACTOR

Parabolic

Mu

MIN p

pu
f 'c

d '

, 0.17

dp

2 0.85 f C'

o =

fC=

0.85 f C' 2

ps

= MIN

se + 10 +

f
, f y, f
100 p

se + 60

, E c = 57 f C' , E s = 29000ksi

c
o
o

, for 0 < c < o

0.85 f C' , for c o


fS=

243.940

ksi

s E s , for s t
f y , for s > t

STRESS IN UNBOUNDED TENDONS :


'
c

Ec

Not applicable

s,max =
c=

0.0021
98.2

, (ACI 318-08 10.3.4 & 10.3.5)


in, by pure math method

Fc =

32282.5

kips

dc =

47.3

in

Mn = 2603343 ft-k
'

ps

= MIN f se +10 +

fc
, f y, f se + 30 =
300 p

1.2M cr = 1.2 S b P e

1
Ac

S cb
1 =
Sb

+ 7.5 f c' M G

Sb

Mu
>
[Satisfactory]

Not applicable

136462

Mn
ft-k
<
[Satisfactory]
(AASHTO 9.18.2 & ACI 318-08 18.8.2)

CHECK SHEAR CAPACITY (AASHTO 9.20, ACI 318-08 11.1 & 11.4)

d = MAX ( 0.8h , d p ) =

Vc =

MAX MIN
2b wd

V s = MIN

'
c

84.00

0.6 f 'c + 700 MIN 1 ,

, for

f se < 0.4 f

Av f yd
, 8b wd f c' =
S

f 'c = MIN 100 ,

in

V ud p

b wd , 5b wd

Mu

f 'c

, 2b wd

f 'c

( f c' )

, for

psi

se

0.4 f

pu

5441.73

kips

pu

A ps f

MIN ( 0.75d , 24 ) , for V s 4b wd

puS

__

3200.40

kips

Av (min) =

50b wS
,
MAX
fy

80df

50b wS
, for f se < 0.4 f
fy

S max =

77.46

provd

MIN ( 0.375d , 12 ) , for V s > 4b wd

f 'c

f 'c

24.00

in

Page 198 of 533


524

bw

pu

, for f se 0.4 f

pu

1.867

in2

(Cont'd)

no shear re inf . requd , for case1: V u <


Av,requd

= Av (min) , for case 2 :

V c

V c
2

V u V c

=
2
MAX ( Av ,cal , Av (min) ) , for case 3 : V c V u (V S + V c )

4.434

in

[Satisfactory], Case 3 applicable

Tu

>

f 'c

unsatisfactory , for case 4 : (V S + V c ) V u

CHECK TORSIONAL CAPACITY (AASHTO 9.21, ACI 318-08 11.1 & 11.5)
Acp

26880

in2

Pcp

752

in

fpc

0.708

ksi

Aoh

25293

in

Ph

735

in

At =
Tu
=
S 1.7 Aoh f yv cos ( 37.5 )

At
S

Total Re qD

2
Acp

P cp

1+

pc

4 f 'c

5277.761 ft-kips

Thus, Torsional Reinf. Reqd.

0.020

+2
50b w
= MAX Av At ,
=
S
f yv

A L = MAX

in /in

0.595

in /in

<

f yv
f yv
5 Acp f c'
25b w
At
max At ,
Ph
cot 2 ( 37.5 ) ,
Ph
S
S
f yL
f yL
f yL
f yv

At
S

0.635

in /in

Pr ovD

[Satisfactory]

__
Page 199 of 533
524

87.77

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Concrete Tunnel Design Based on AASHTO-17th & ACI 318-08


INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc' =

ksi

REBAR YIELD STRESS

fy =

60

ksi

TUNNEL DIMENSIONS

L=
H=
C=
S=
D=
t=

32
16
9.9
16
60
20

ft, (AASHTO Fig 2.5)


ft, (AASHTO Fig 2.5)
ft
in
in
in

REINFORCING (As)
2
layers #
9
@
8
in o.c. (curvered)
Concrete Cover =
3
in, (AASHTO 8.22.1)
FACTORED SOIL PRESSURE (SD level, including surcharge & seismic ground shaking)
Pt =

1760

psf

P1 =

720

ft-pcf, (psf)

Pb = Pt + Wt =
P2 =

1820

DETERMINE TUNNEL FORCES BY FINITE ELEMENT METHOD


X (ft)
Y (ft)
Mu (ft-k)
Point
Pu (k)

Vu (k)

2671

psf

[THE DESIGN IS ADEQUATE.]

ft-pcf, (psf)

ANALYSIS

0
1
2
3
4
5
6
7
8
9
10
11
12
13

0.00
3.40
6.73
9.96
13.03
15.89
17.29
18.23
18.68
18.63
18.09
17.06
15.57
13.67

0.00
0.22
0.87
1.94
3.41
5.26
7.98
10.89
13.92
16.98
20.00
22.88
25.56
27.96

24.97
25.83
27.51
29.95
33.08
40.68
41.81
42.16
41.52
40.02
37.82
34.98
31.65
28.09

124.44
116.28
91.87
52.18
-1.21
-66.10
-83.43
-95.13
-99.43
-95.39
-83.08
-63.29
-37.55
-8.14

0.00
7.17
11.67
15.69
19.07
5.66
3.82
1.40
-1.32
-4.02
-6.46
-8.41
-9.61
-9.87

14

11.40

30.01

24.62

22.10

-9.12

Rt =

18.72

ft, (top circle radius)

15

8.83

31.68

21.60

50.02

-7.37

Rb =

26.62

ft, (bottom circle radius)

16

6.02

32.89

19.37

72.60

-4.79

t =

121.95

deg, (between 5 & 18)

17

3.05

33.64

18.18

87.28

-1.66

b =

36.63

deg, (between 0 & 5)

18

0.00

33.89

18.18

92.37

0.00

CHECK AXIAL & FLEXURE CAPACITY


<
ProvD = 0.007605
>
[Satisfactory]

MAX =
MIN =

0.0400
0.0008

(tension face only, ACI 318-05 10.3.5 or 10.9.1)


(tension face only, ACI 318-05 10.5.1, 10.5.3 or 14.3.2)

700.0
600.0
500.0
AT AXIAL LOAD ONLY
AT MAXIMUM LOAD

400.0
Pn (k)

300.0
200.0
100.0

Pn

Mn

617.4
617.4

0.0
17.2

AT MIDDLE

377.3

126.1

AT t = 0.002
AT BALANCED
AT t = 0.005
AT FLEXURE ONLY

137.2
130.2
54.6
0.0

184.6
186.6
221.6
105.0

__

(Note: For middle reforcing the max M n is at c

0.0
0.0

50.0

100.0

150.0

200.0

250.0

Mn (ft-k)

equal to 0.5 t / 1 , not at balanced condition.)


[Satisfactory]

CHECK SHEAR CAPACITY (ACI 318-08 SEC.15.5.2, 11.1.3.1, & 11.2)

V n = 2 bd f c'

20.92

kips / ft

>

V u, max =

Page 200 of 533


524

19.07

kips / ft

[Satisfactory]

PROJECT :

PAGE :

CLIENT :
JOB NO. :

DESIGN BY :
REVIEW BY :

DATE :

Concrete Design for Prestressed Double Tee Section Based on AASHTO 17th Edition & ACI 318-08
INPUT DATA & DESIGN SUMMARY
BEAM SPAN
L=
UNTOPPED SECTION DIMENSIONS
B=
60
in

45

ft
UNTOPPED SECTION PROPERTIES
in2
A=
449.0

C=

30

in

yt =

6.23

in

D=

24

in

yb =

17.77

in

Tt =

5.75

in

I=

22469

in4

Tb =

3.75

in

St =

3609

in3

Tc =

in

Sb =

1264

in3

Te =

in

Wt =

468

lbs / ft, ( 47 psf )

CONCRETE STRENGTH
REBAR STRENGTH
TENDON TENSILE STRENGTH

f 'c =

ksi

fy* = fy =

60

ksi

THE DESIGN IS ADEQUATE.

fsu* = fpu =

270

ksi

TOTAL TENDON FORCE IMMEDIATELY AFTER PRESTRESS TRANSFER

fpy =

243

ksi

Pi = 330.48 kips, (double tee)


TOTAL TENDON FORCE AT SERVICE LOAD AFTER ALLOWANCE LOSSES

0.5

in dia. &

TENDON YIELD STRENGTH


TOTAL PRESTRESSING TENDONS
6

Pe =

strands (

DIST. TO CENTROID OF BOT. PRESTRESSED


BOTTOM TENSION REINF.
1
TOPPING

t=

in, with #

264.384

kips, (double tee)

in2 area per strand ) , at Each Leg

18.3
in
at Each Leg

dp =
6

PRESTRESSING METHOD ( 0, 1 or 2 )
EXPOSURE ( 0 OR 1 )
SECTION LOCATION ( 0, 1 or 2 )
SHEAR STIRRUP REINF.

0.153

12

SUPERIMPOSED LOADS

DL =
LL =
Total Loads =

FACTORED VERT. SHEAR FORCE

10

Vu =

CHECK TRANSFER LOAD CONDITION (AASHTO 9.15.1 & 9.15.2.1)

ksi

Fbi =
3.300
MAX. ALLOWABLE STRESS

ksi

Fsi =

f si

=
<

189.000

ksi

180.000

ksi

Fsi

[Satisfactory]

f ti

1 e MG
Pi  
A St St

0.024

ksi

>
- Fti
[Satisfactory]

f bi

1 e MG
Pi  
A Sb Sb

2.769

ksi

<
Fbi
[Satisfactory]

where

MG =

118.389

ft-k

CHECK SERVICEABILITY LOAD CONDITION (AASHTO 9.15.1 & 9.15.2.2)


CONCRETE DECK TOPPING
t=
2
in
(0 for non-composite)
COMPOSITE SECTION PROPERTIES
b=
120
in
in2
Ac =
689.0

yct =

5.71

ycb =

20.29

in

Ic =

116686

in4

Sct =

20438

in3

Scb =

5751

in3

in

MIN. TOP FIBER STRESS

3.600

ksi, for total loads

Fte, G+D = 0.4fc' =

2.400

ksi, for sustained loads only

2.400

ksi, for live + 50% sustained loads

Fte, 0.5(G+D)+L = 0.4fc' =


f se

MAX. BOT. FIBER STRESS

Fte = 0.6fc' =

144.000

ksi

<
Fse
[Satisfactory]

140.109

k, (SD)

FACTORED LATERAL BENDING MOMENT


Mu,y =
1576.230 ft-k, (SD)
(Seismic/Wind Horizontal Bending Load)
in o. c.

ENTIRE SECTION PRESTRESSED ECCENTRICITY


e=
12.07
in
MIN. TOP FIBER STRESS

- Fti =
-0.581
MAX. BOT. FIBER STRESS

psf, (ASD)
psf, (ASD)
psf, (ASD)

in. o.c., trans. way

post-tensioned & bonded

0
mild exposure
0
at midspan
E. Leg, #
4

30
100
623

-Fbe = -(0, 3, or 6)(fc')0.5 =

-0.465

ksi

MAX. ALLOWABLE STRESS


Fse = 0.8fy = 194.400

ksi, after all losses

(Cont'd)

1 e MGMDML
Pe  
S ct
A St

f te

0.699 ksi

1 e MGMD
Pe  
S ct
A St

f te,G  D

0.551 ksi

1 e 0.5( M G  M D )  M L
0.5P e  
S ct
A St

f te,0.5(G  D ) L

1 e MGMDML
Pe  
S cb
A Sb

f be

<

0.424

-0.422 ksi

Fte

[Satisfactory]

where

MD =

1323.105 ft-k

ML =

253.125

ft-k

[Satisfactory]

<

Fte, G+D

kis

<
Fte, 0.5(G+D)+L
[Satisfactory]

>

-Fbe

[Satisfactory]

CHECK ULTIMATE LOAD CONDITION (AASHTO 9.15.1 & 9.17 ACI 318-08 18.7)
FACTORED ULTIMATE MOMENT

Hc = 0.003

Mu,x = J( ED MD + EL ML ) = 1.3 [ 1.0 ( MG + MD) + 1.67 ML]

0.85 f c'

(AASHTO Eq. 3-10)


=

2423.477

ft-k

Mu,y =

1576.230

ft-k

A s' f s'
Fc

2 0.5

Mu = (Mu,x + Mu,y )
= 2890.976 ft-k

Parabolic

Mu
T=

33.0

deg

COMPRESSION ZONE FACTOR


E1 =
0.75
TENDON TYPE FACTOR

, (ACI 318-08 R10.2.7)

Jp =
0.280
RATIO OF TENSION REINF.
RATIO OF COMPR. REINF.

, (ACI 318-08 18.7.2)


U=
0.001
U' =
0.000

Asfy

, (ACI 318-08 Chapter 2)


, (ACI 318-08 Chapter 2)

RATIO OF PRESTR. REINF.


INDEX OF TENSION REINF.
INDEX OF COMPR. REINF.

Up =
Z=
Z' =

0.002
0.006
0.000

, (ACI 318-08 Chapter 2)


, (ACI 318-08 18.7.2)
, (ACI 318-08 18.7.2)

INDEX OF PRESTR. REINF.


STRESS IN BONDED TENDONS :

Zp =

0.070

, (ACI 318-08 18.7.2)

ps

pu

A ps f ps

d Z Z'
f
1  p u MIN U p pu 
'

E1
fc
dp

, 0.17

2 0.85 f 'C

Ho

Ec

ps

f 'c
,f ,f
se  10 
100 U p y

se  60

ksi

Not applicable

Hs,max =
c=

0.0021
23.8

Fc =

316.7

dc =

9.3

I Mn =

ps

'

fc
, f y, f se  30
MIN f se 10 

300 U p

1.2M cr

47

11972

, (ACI 318-08 10.3.4 & 10.3.5)


in, by pure math method
kips
in
ft-k

>
Mu
[Satisfactory]

Not applicable

1
S cb

e
'
1.2S b P e

 1
 7.5 f c  M G
Sb

Ac S b

29000ksi


0.85 f C' 2 H c  H c , for 0  H c  H o

H o H o

'
0.85 f C , for H c t H o
H s E s , for H s d H t
f , for
Hs !Ht
y

fC

STRESS IN UNBOUNDED TENDONS :

MIN f

, E c 57 f C' , E s
2

fS
252.864

ft-k
<
I Mn
[Satisfactory]
(AASHTO 9.18.2 & ACI 318-08 18.8.2)

CHECK SHEAR CAPACITY (AASHTO 9.20, ACI 318-08 11.1 & 11.4)

MAX 0.8h , d p

Vc

Vs

S max

MAX

2b wd

19.20

V ud p

'
MIN 0.6 f c  700 MIN 1 ,
b wd , 5b wd
M u

f 'c , for

se

 0.4 f

Av f yd

MIN
, 8b wd f 'c
S

MIN 100 ,

f 'c

in

f 'c , 2b wd

f c'

f 'c , for

provd

se

77.46

t 0.4 f

psi

pu

178.47

kips

pu

92.16

kips

MIN 0.75d , 24 , for V d 4b d f '


s
w
c

'

MIN
0.375
d
,
12
,
for
!
4
d
f


V
b
s
w
c

Av (min)

14.40

A ps f puS

bw
MAX 50b wS ,
fy
80df y

50b wS
, for f se  0.4 f pu

f y

in

, for f t 0.4 f
se

pu

0.500

in2

(Cont'd)

Av  requd

no shear re  

 for
Av     

MAX Av  cal 

unsatisfactory

for case1
V u 

 requd 

IV c

case

Av  


 

IV c

d V u d IV c

0.500

for case
IV c d V u d I V S  V c

for case
I V S  V c d V u

CHECK CANTILEVER CAPACITY OF SLAB / DECK (AASHTO 9, ACI 318-08 10 & 11)
dend slab =

3.00

in

I Mn,slab =

2612

lbs-ft / ft

>

Mu,slab =

1591

lbs-ft / ft

[Satisfactory]

I Vn,slab =

4183

lbs / ft

>

Vu,slab =

1408

lbs / ft

[Satisfactory]

in2

[Satisfactory], Case 2 ap p licable

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Concrete Box Culvert Design Based on AASHTO 17th & ACI 318-08
INPUT DATA & DESIGN SUMMARY
CONCRETE STRENGTH

fc'

3.5

ksi

REBAR YIELD STRESS

fy

60

ksi

Pa

45

pcf

LATERAL SOIL PRESSURE

(equivalent fluid pressure)


BACKFILL WEIGHT

Jb

TOP LIVE SURCHARGE


ONE WHEEL LOAD (HS20 Min.)
SEISMIC GROUND SHAKING

140

pcf

ws

100

psf, vertical

18

kips

PE

20

psf /ft, ASD

(soil pressure, if no report 35SDS suggested. )

THICKNESS OF TOP SLAB

ts

10

in

10

in o.c.

SLAB TRANS REBARS

SLAB BAR LOCATION (1=at middle, 2=at top & bot)

[THE DESIGN IS ADEQUATE.]

at top & bottom


DEPTH OF FILL.

THICKNESS OF WALL

tw

WALL VERTICAL REBARS

in

WALL BAR LOCATION (1=at middle, 2=at each face)

THICKNESS OF FLOOR

tf

12

FLOOR TRANS REBARS

FLOOR BAR LOCATION (1=at middle, 2=at top & bot)

D
12

in o.c.

at each face

2.8

ft

10

ft

ft

DIMENSION

in
12

in o.c.

at top & bottom

ANALYSIS
CHECK TOP SLAB CAPACITY
Mu = (1.2 Jb D + 1.6 ws) B2 / 8 + 1.6 P I B / (4 E) =
Vu = (1.2 Jb D + 1.6 ws) B / 2 + 1.6 P I / E =
Pu =

kips / ft, (possible max shear force conservatively)

1.113 Impact Factor (AASHTO 17 3.8.2.3)

Min[ 7 ,Max( 4 + 0.12 B , 1.75 D)] =

I M n I AS f y d 

IV n

7.77

ft-kips / ft, (possible max moment conservatively)

slab axial force, zero conservatively, since tension controlled. (ACI 318-08 Fig. R9.3.2)

where

UProvD =

15.55

0.0058

2I bd

'
c

AS f y  P u

'
1.7bf c

17.06

4.96

ft-kips / ft

Mu

>

[Satisfactory]

, (ACI 318-08 9 & 10)

<

UMAX = 0.0181 , (ACI 318-08 10.3.5)

>

UMIN =
=

ft, point load to load per linear foot

0.0033 , (ACI 318-08 10.5)


8.12

kips / ft

[Satisfactory]
>

Vu

[Satisfactory]

, (ACI 318-08 9 & 11)


where

d =

7.63 in,

in,

As =

0.528

in2 / ft

b =

12

2.25

kips / ft ,

JHb = 1.6 Hb

3.60 kips / ft

0.49

kips / ft ,

JHs = 1.6 Hs

0.78 kips / ft

1.00

kips / ft ,

JHE =

=
1.6 HE =

1.60 kips / ft

WALL LATERAL LOADS


Hb = 0.5 Pa H2

Hs = Pa D + Max(36 lbs/ft , ws Pa / Jb) H =


2

HE = 0.5 PE H

(cont'd)
CHECK WALL CAPACITY
Mu = (0.1875 JHs + 0.175 JHb + 0.100 JHE) H
9.36

ft-kips / ft, (possible max moment conservatively)

Vu = JHs + JHb + JHE =


Pu =

2.63

5.98

kips / ft

kips / ft, (DL only, since tension controlled.)

200.0
180.0
160.0
140.0
I Pn (k)

120.0
100.0

I Pn

I Mn

80.0

AT AXIAL LOAD ONLY

185.5

0.0

60.0

AT MAXIMUM LOAD

185.5

6.2

AT MIDDLE

118.5

18.2

40.0
20.0
0.0
0.0

5.0

10.0

15.0

20.0

25.0

30.0

ATHt = 0.002

51.5

21.8

AT BALANCED

49.8

21.9

ATHt = 0.005

31.3

24.7

AT FLEXURE ONLY

0.0

9.0

(Note: For middle reforming the max I M n is at c


I Mn (ft-k)
Pu =

2.63

kips / ft

Mu =

9.36

ft-kips / ft

IV n

2I bd

'
c

equal to 0.5 t / E 1 , not at balanced condition.)


, (ACI 318-08 9 & 10)

[Satisfactory]

7.12

kips / ft

>

Vu

[Satisfactory]

, (ACI 318-08 9 & 11)


d =

where

6.69 in,

b =

12

As =

in,

0.310

in2 / ft

CHECK BOTTOM FLOOR CAPACITY


Mu = [1.2 Jb D + 1.6 ws + 1.6 P I / (E B) + 1.2 (0.15) (ts - tf)] B2 / 8 =
Vu = 4 Mu / B =
Pu =

4.42

IV n

0.0038

2I bd

ft-kips / ft, (max moment conservatively)

kips / ft, (possible max shear force conservatively)

floor axial force, zero conservatively, since tension controlled. (ACI 318-08 Fig. R9.3.2)

I M n I AS f y d 

UProvD =

8.85

'
c

AS f y  P u

'
1.7bf c

18.33

ft-kips / ft

>

<

UMAX = 0.0181 , (ACI 318-08 10.3.5)

>

UMIN =
=

Mu

[Satisfactory]

, (ACI 318-08 9 & 10)

0.0033 , (ACI 318-08 10.5)


10.25

kips / ft

[Satisfactory]
>

Vu

[Satisfactory]

, (ACI 318-08 9 & 11)


where

d =

9.63 in,

b =

12

in,

As =

0.440

in2 / ft

PROJECT :
PAGE :
CLIENT :
DESIGN BY :
JOB NO. :
DATE :
REVIEW BY :
Steel Road Plate Design Based on AASHTO 17th Edition & AISC 360-10 using Finite Element Method
INPUT DATA & DESIGN SUMMARY
MAXIMUM TRENCH WIDTH
(A or B zero for one way trench.)

A=
B=

STEEL PLATE THICKNESS

t=

4
6

ft
ft

W=
L=

1.625 in

(Weight =

TRUCK CONCENTRATED LOAD


P=
26
(26 kips for H20-44, 19.5 kips for H15-44)

kips, (AASHTO Fig. 3.7.6B)

STEEL YIELD STRESS

ksi

Fy =

50

3185

6
8

ft
ft

lbs)

THE DESIGN IS ADEQUATE.


(The Minimum Plate Size: 6 ft x 8 ft x 1.625 in., Wt: 3185 lbs.)

ANALYSIS
IMPACT FACTOR (AASHTO 3.8.2)
I = 1+ Min[ 0.3 , 50/(L + 125) ] =
Where
L = Max(A , B) =

1.30
6.0

ft

JOINT DEFLECTIONS, REACTIONS, & PLATE SECTION FORCES


kips,( Truck point load at Joint 9.)
PI=
33.8
Joint
Number
1
2
3
4
5
6
7
8
9

'
in
0
0.60
0.85
0.19
0.69
0.92
0.26
0.74
0.99

R
kips
-9.246

Bending

Section
7-8
8-9
3-6
6-9

Minimum W =
Minimum L =
E=
29000

CHECK BENDING CAPACITY (AISC 360-10, F11)


Mn / : b =
19.8
ft-k/ft
Where

M n = Min( F y Z , 1.6 M y ) =

>

M =

1.67
d=
12.0
Z = d t2/ 4 =

, (AISC 360-10, F1)


in
in3
7.9

My = Fy d t2/ 6 =

22.0

V n =0.6 F y A w C v =

:b =

1.67

Cv =

1.00

ft, for FEM calculation


ft, for FEM calculation

ksi

17.4

ft-k/ft, (Max section average moment.)

ft-kips

V =

>

3510.0 kips
, (AISC 360-10, G1)

A w =Min (A + 2 , B +2, 8 ft) t =

6
8

[Satisfactory]
33.0
ft-kips

:b =

CHECK SHEAR CAPACITY (AISC 360-10, G2)


Vn / :v =
2101.8
kips
Where

M
ft-k/ft
8.63
10.54
16.55
18.26

117.0

in

33.8

kips

[Satisfactory]

PROJECT :

PAGE :

CLIENT :
JOB NO. :

DESIGN BY :
REVIEW BY :

DATE :

Prestressed Concrete Circular Hollow Pole/Pile Design Based on ACI 318-11 & AASHTO 17th
INPUT DATA & DESIGN SUMMARY
OVERALL LENGTH
SMALL END DIAMETER

L=
DS =

85
11

ft
in
in

TS =

2.76

DL =

29.4

in

TL =

3.5

in

LOCATION OF CRITICAL CROSS SECTION


D=
27.2
in
T=
3.4
in
4
I=
18491.3 in

C=

10

ft

A=
S=

255.4
1357.9

in
3
in

WEB THICKNESS
LARGE END DIAMETER
WEB THICKNESS

SHIPPING & ERECTION LOADS AT CRITICAL CROSS SECTION (ASD level)


P=
-15.77 kips, axial tension
V=
7.885 kips, shear
M=
335.1125 ft-kips, bending

THE DESIGN IS ADEQUATE.

FACTORED ULTIMATE LOADS AT CRITICAL CROSS SECTION (SD level)


Pu =

10

kips, axial

Mu =

406

ft-kips, bending

Vu =

12

kips, shear

Tu =

150

ft-kips, torsion

f 'c =

ksi

fy* = fy =

60

ksi

fsu* = fpu =

270

ksi

fpy =

243

ksi

CONCRETE STRENGTH
REBAR STRENGTH
STRAND TENSILE STRENGTH
STRAND YIELD STRENGTH
PRESTRESSING STRAND

strands

16

PRESTRESSING METHOD ( 0, 1 or 2 )

(each

0.5

in dia. &

0.153

pre-tensioned

in2 area )

STRAND FORCE IMMEDIATELY AFTER PRESTRESS TRANSFER

0.75

f py , (ACI 318-11 18.5)

Pi =

446.1

kips

STRAND FORCE AT SERVICE LOAD AFTER ALLOWANCE LOSSES

0.6

f py , (ACI 318-11 18.6)

Pe =

356.9

kips

VERTICAL REINFORCEMENT ( 0 bars for not apply)


LATERAL REINF. OPTION (0=Spirals, 1=Ties)
LATERAL REINFORCEMENT
#
4

4
0
12

#
Spirals
in o.c.

ANALYSIS
CHECK TRANSFER (SHIPPING & ERECTION) LOAD CONDITION (ACI 318 18.4.1, 18.5.1, AASHTO 9.15.1 & 9.15.2.1)
TENSION FIBER STRESS

- Fti =

-0.712

COMPRESSION FIBER STRESS

Fpi =

5.400

ksi, (AASHTO 9.15.2.1)

STRAND ALLOWABLE STRESS

Fsi =

216.00

ksi, (ACI 318 18.5.1)

f si

182.25

ksi

ksi, (AASHTO 9.15.2.1)

Fsi

<

[Satisfactory]
f

ti

pi

Pi  P  M
A
A
S

-1.277

ksi

- Fti
<
[MIN. As' REQUIRED]

Pi  P  M
A
A
S

4.646

ksi

Fpi
<
[Satisfactory]

(As')reqd

=
1.171 in
(ACI 318-11 R18.4.1)

(As')provd
<
[Satisfactory]

CHECK SERVICEABILITY LOAD CONDITION (ACI 318 18.3.3 & 18.4)


SERVICE LOADS
P=

Pu /

1.2

8.3

kips, axial

M=

Mu /

1.4

290.0

ft-kips, bending

TENSION FIBER STRESS

- Fte =

-1.138

COMPRESSION FIBER STRESS

Fpe =

4.050

ksi, (ACI 318 18.4.2)

STRAND ALLOWABLE STRESS

Fse =

216.00

ksi, (ACI 318 18.5.1)

f se

145.80

ksi

<

ksi, (Class U or T, ACI 318 18.3.3)

Fse

[Satisfactory]

f te

Pe P M
 
A A S

-1.133

ksi

>

- Fti

[Satisfactory]

pe

Pe  P  M
A A S

3.993

ksi

Fpi
<
[Satisfactory]

(Cont'd)

CHECK ULTIMATE LOAD CONDITION (AASHTO 9.15.1 & 9.17 ACI 318-11 18.7)
2000.0

Ho

I Pn (k)

2 0.85 f

1500.0

Ec

1000.0

0.85 f

0.85 f

500.0

PS

0.0
0.0

100.0

200.0

300.0

400.0

500.0

600.0

700.0

-500.0

'
C

'
C

ft-kips @ Pu =

10

kips

>

Mu

142

where I =

0.75

>

psi

vu

(ACI 318-11 9.3.2.3)

vc = 2 (fc')0.5 =

190

psi

Av = 0.8 A =

204.3

in

vu = [Vu + Tu / (0.5D - T) ] / Av =

131

psi

'
C

, for H c t H o
,
for H s d H y

H
E
s
s

,
for
f
Hs !H y

Pe
, F se
Min H s E s 

A ps

[Satisfactory]

CHECK SHEAR & TORSIONAL CAPACITY (ACI 318-11 11.3)


I vn = I (vc) =

'
C

I Mn (ft-k)
618.4

57

H H 2
2 c  c ,
H o H o

-1000.0

I Mn =

, Ec

[Satisfactory]

, Es

29000ksi

for 0  H c  H o

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Falsework Design for Steel Girder Bridge Based on NDS 2012 & AASHTO 17th
INPUT DATA & DESIGN SUMMARY
DECK FORM
3/4
in, plywood

JOISTS

12

2x4
in. O. C., (No. 2, Douglas Fir-Larch)

48

2 x 12
in. O. C., (No. 1, Douglas Fir-Larch)

@
WALERS
@

WALER SPAN (Hanger to Hanger)

ft

CONCRETE DECK THICKNESS

in

THE FALSEWORK DESIGN IS ADEQUATE.

ANALYSIS
CHECK BENDING CAPACITY OF DECK FORM
M = w L2 / 8 =
<
CDFbS =
259.69 in-lbs / ft
where w =
120
+
50
+
3.13
=
(conc wt, 160 pcf)
(LL)
(plywood)
12
in
L=
CD =
1.25 , (NDS 2012 Table 2.3.2)

FbS =
CHECK JOISTS
fb = M / S =
where w =

250

M = w L 2 / 10 =
4.00
L=
S=
3.06
CF =
1.50

<
CDCFCVCLFb =
1.00
+
1.8229
=
174.95
(Spacing)
(joist wt)
279.92 ft-lbs
ft
3
in
, (NDS 2012 Section 4.3.6)

CV =

, (NDS 2012 Section 5.3.6)

1096.8 psi
173.13
x

1.00

F = F bE / F b * =
Fb =

900.0

f v = 3V / 2A =
120.0
where V = 0.6 w L =
A=
5.25
Fv =

= w L 4 / 145 EI =
w=
E=
I=

180.0
0.044
124.95
1600
5.36

0.98

psi, (No. 2, Douglas Fir-Larch)


psi
419.9
in2

<

<==

Fb =

1000.0

f v = 3V / 2A =
138.9
where V = 0.5 w L =

psi

[Satisfactory]

3
225.0

CDFv =

of 1 to 6
psi

[Satisfactory]

lbs

psi, (No. 2, Douglas Fir-Larch)


in
L / 360 =
<
lbs / ft, (no live load)
ksi, (No. 2, Douglas Fir-Larch)
in4

0.133 in

[Satisfactory]

1234.1
lbs / ft

psi

[Satisfactory]

, (NDS 2012 Section 5.3.6)

2
0.5
=
C L = (1+F) / 1.9 - [((1+F) / 1.9) - F / 0.95]

F = F bE / F b * =

1647.5
lbs / ft

, (NDS 2012 Section 3.3.3)

1185.5 psi
<
CDCFCVCLFb =
769.77
/
1.00
+
11.719
=
781.49
(1.1 x Reaction)
(Spacing)
(waler wt)
2
M=wL /8=
6251.9 ft-lbs
L=
8.00 ft
S=
63.28 in3
CF =
1.00 , (NDS 2012 Section 4.3.6)
1.00

[Satisfactory]

2.99

CHECK WALERS
fb = M / S =
where w =

CV =

in-lbs / ft
psf

psf, (NDS 2012 Table M9.2-1 or C3.2A)

C L = (1+F) / 1.9 - [((1+F) / 1.9) 2 - F / 0.95] 0.5 =

where

312.50
173.13

4.82

0.99
1

, (where L u =

psi, (No. 1, Douglas Fir-Larch)


psi
3126.0 lbs

<

CDFv =

, (NDS 2012 Section 3.3.3)

ft, joist spacing for NDS 2012 Table 3.3.3)


<==

2
225.0

of 1 to 6
psi

[Satisfactory]

(Cont'd)
A=
Fv =

= 5 w L 4 / 384 EI =
where

w=
E=
I=

33.75
180.0
0.119
781.49
1,700
355.96

in2
psi, (No. 1, Douglas Fir-Larch)
in
lbs / ft
ksi, ()
4
in

<

4.69
kips
Hanger Load, T = 1.5 V =
Minimum Bracket Bearing Area, A b = T / 400 psi =
Minimum Hanger Diameter, d = (4T / 24 ksi )

0.267 in

L / 360 =

0.5

2
11.72 in

0.50

in

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Polygon Section Member (Tubular Steel Pole) Design Based on ASCE 48-11
INPUT DATA & DESIGN SUMMARY
STEEL YIELD STRESS
SECTION DIMENSIONS

PAGE :
DESIGN BY :
REVIEW BY :

Fy =
50
ksi
t=
0.5 in
D=
20
in
8
n=
(Octagonal 8-Sided Polygon Section)

POLYGON SIDE NUMBER (6, 8, 12, or 16 only)

AXIAL LOAD, SD level (Factored Section Force)


AXIS, x-x, BENDING LOAD, SD level

P=
Mx =

525
150

kips
ft-kips

AXIS, y-y, BENDING LOAD, SD level


SHEAR LOAD, SD level
TORSIONAL LOAD, SD level

My =
V=
T=

0.15
150
20

ft-kips
kips
ft-kips

UNBRACED AXIAL LENGTH

KL =

50

THE DESIGN IS ADEQUATE.


ft

ANALYSIS
DETERMINE SECTION PROPERTIES (ASCE 48-11 Appendix II)
BR =Min( actual , 4 t ) =
2
in, effective bend radius.
T=
22.5
deg
2
Ag =
3.32
Dt =
33.200 in
Ix = Iy =

0.438

cx =

0.541

cy =

0.541

r =
w=

0.364 D =
7.280
0.414 (D - t - 2 BR) =

in
6.417

in

1752.00 in
(D + t) Cos T =
10.246
(D + t) Sin T =
4.244
D t =

in

Max. Q / I t =

in

Max. c / J =

0.618 / D t =

0.062

3
0.603 (D + t) / (D t) =

0.0031

CHECK COMBINED STRESSES (ASCE 48-11 5.2)

2
P  M xc y  M y c x 3 VQ  Tc

A
J
It
Ix
I y

Where

k=

(1/ 2)

(0.877 I c ) = 0.877 x 0.9 =

Ft =

F a , Beam

k1 =
:=

F a ,Truss

KL / r =

VQ 1 Tc

It t J

Fy =

50.0

>

k2 =

for k 1

Fy

w
d k2
t

,
19.3

Cc =

<

T / k Ag =

ksi

50.0

351

k3 =

0.0

ksi, (ASCE 48-11 5.2.3.2.1)

1.42

P / k Ag =

k4 =

35.2

ksi, (ASCE 48-11 5.2.3.2.1)

>

P / k Ag =
20.0
[Satisfactory]

22.9

ksi

20.0 ksi
[Satisfactory]

0.00114

107.0 , (ASCE 48-11 Eq. 5.2-5)


k F v = k 0.58F y =

ksi
[Satisfactory]

Fy

>


F y 1  0.5 KL , for KL d C c

r
r C c

KL
S 2E

, for
! Cc
2
r

KL

82.4

27.8

0.7893 , from AISC 360-10 E3-3 & E1 than ASCE 48-11 Eq. 5.2-4

ksi, (ASCE 48-11 Eq. 5.2-1)

k (F a or F t) =

[Satisfactory]

w
:

F y , for t d k 1
Fy

Fy w

,
k 3 F y 1.0  k 4

:
t

0 , for w ! k 2 :

t
Fy

260
1.0

<

26.6

[Satisfactory]

ksi

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Mounting Design on Concrete Wall/Tunnel Based on FEMA E-74, 2012 IBC, and 2013 CBC Chapter A

INPUT DATA & DESIGN SUMMARY


EQUIPMENT WEIGHT

3.5

kips

CENTER OF MASS

3.5

ft

ft

STRUT DIMENSION

ft
in. Per ICC ESR-1917

KWIK BOLT-TZ DIAMETER

3/4

ANCHOR DEPTH

hef

4 3/4

in. Per ICC ESR-1917

EDGE DISTANCE

12

in

ANCHOR MINIMUM SPACING

10

in

[THE ANCHORAGE, KWIK BOLT-TZ, DESIGN IS ADEQUATE.]

ANALYSIS
TENSION & SHEAR CAPACITY (SD - 2013 CBC 1909A,and ASD - ICC ESR-1917, 4.2)
IPn,t =
IVn,t =

7399.5

lbs, 2013 CBC 1905A & ACI 318-11 App.D

Pt =

4933

lbs, T allowable,ASD

8838.2

lbs, 2013 CBC 1905A & ACI 318-11 App.D

Vt =

6313

lbs, V allowable,ASD

SPACING & EDGE REQUIREMENTS (ICC ESR-1917, Table 3 or 4)


Scr

7 3/4

in, (Critical Spacing for Kedge-space based on ACI 318-11 Appendix D)

Smin

in

Ccr

8 7/8

in, shear,

8 7/8

in, tension

Cmin

4 1/8

in, shear,

4 1/8

in, tension

DESIGN LOADS
FH = F p =

:0 (KH) MAX{ 0.3SDSIpW , MIN[ 0.4apSDSIp(1+2z/h)/Rp W , 1.6SDSIpW ] }


= 1.5 (1.3) MAX{ 0.43W , MIN[ 0.81W , 2.30W ]}
=

1.58 W , (SD) =

1.13 W , (ASD)

FV = K V W =

0.25 W , (SD)
0.18 W , (ASD)

=
=

KV = KH 0.2 SDS / 1.4 =

0.18

where

, (ASCE 7-10, Sec. 13.3.1)


SDS =

0.96

(ASCE 7-10 Sec 11.4.4)

1.5

(ASCE Sec. 13.1.3)

5.53

kips

Ip =

3.95

kips

ap =

(ASCE Tab. 13.6-1)

Rp =

1.5

(ASCE Tab. 13.6-1)

0.87

kips, up & down

z=

20

ft

0.62

kips, up & down

h=

36

ft

:0 =

1.5

(ASCE 7-10 Supp. 1 Tab. 13.6-1)

KH =

1.3

(This option only for local

(vertical seismic factor)

jurisdiction amendments to the code.)


CHECK TENSION CAPACITY
Pu,s =

1.50

Ps =

5520

Ps = [(FV + W) L + FH H ] / (nt S) =
where

nt =

KDSA =

0.8

Kseismic =

lbs / bolt, SD
3680

<

lbs / bolt, ASD

IPn,t

<

[SATISFACTORY]
Pt KDSA Kseismic Kedge-space

, (total bolts at top tension)


(DSA/OSHPD adapted ICBO / ICC value)
1 1/3

Kedge-space =

(allowable increase? CBC 1605A.3.2)

1.00

(ICC ESR-1917 Sec. 4.2.1 SIM.)

5774

lbs / bolt, SD

CHECK SHEAR CAPACITY


Vu,s =

1.40

Vs =

Vs = (W + FV) / nb =
where

nb =

4124
1

lbs / bolt, ASD

<
<

IVn,t

, (total bolts at bottom shear)

Kedge-space =

1.00

(ICC ESR-1917 Sec. 4.2.1 SIM.)

CHECK COMBINED LOADING CAPACITY (ACI 318-11 D1.7 & ICC ESR-1917 Sec. 4.2.2)
(Pu,s / IPn,t) + (Vu,s / IVn,t) =

0.964

<

1.20

[SATISFACTORY]

(Ps / Pt) + (Vs / Vt) =

0.904

<

1.20

[SATISFACTORY]

where

Vu,s =

1.40

Vs =

Vs = (W + FV) / (nt + nb) =

[SATISFACTORY]

Vt KDSA Kseismic Kedge-space

1925

lbs / bolt, SD

1375

lbs / bolt, ASD

[SATISFACTORY]

[SATISFACTORY]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Truss Analysis using Finite Element Method


INPUT DATA & DESIGN SUMMARY

TRUSS SPAN LENGTH

L=

150

ft

TRUSS DEPTH

H=

40

ft

BOTTOM CHORD DECK LOAD


kips / ft, (including truss weight
w=
2
and impact factor.)

CONTINUED TOP CHORD SECTION (FLAT)


in2
A=
30.3
Iy =
Ix =

119
3000

CONTINUED BOTTOM CHORD SECTION


in2
A=
30.3

in4, in plane
4

in , out-of plane
ALL WEB MEMBER SECTION
2
A=
16.379 in

Ix =

3000

in4, in plane

Iy =

119

in4, out-of plane

MODULUS OF ELASTICITY
E=

29000

ksi

Design Data (Conservative Values)


Length (ft)

In Plane Support (ft)

P (kips, axial)

M (ft-kips, in plane)

Top Chord

177.00

25.08

180.21

Bottom Chord

150.00

16.67

-9.76 to 12.54

40.48

40.48

-32.00

Web

V (kips, in plane)

1.54

0.06

64.72

17.10

Reaction

R=

150.00

kips

Deflection

' max =

0.311

in, ( 5795 / L )

ANALYSIS
r=
Element

90.31
Joint

ft, radius of top chord


L (ft)

P (kips, axial)

M (ft-kips, in plane)

V (kips, in plane)

Joint

' (in)

12.50

8.41

64.72

15.72

25.08

180.21

1.54

0.06

-0.14

19.09

-18.91

0.00

0.00

-0.15

12.50

12.54

64.72

15.83

-0.20

20.41

-32.00

0.00

0.00

-0.21

20.11

155.49

0.03

0.00

-0.26

16.67

0.51

50.60

17.10

-0.26

30.96

-3.86

0.00

0.00

-0.30

30.96

-29.64

0.00

0.00

-0.29

10

17.98

146.52

0.11

0.00

-0.31

11

37.41

-4.49

0.00

0.00

10

-0.31

12

16.67

-6.47

51.01

16.69

13

37.41

-24.09

0.00

0.00

14

16.99

142.91

0.16

0.00

15

40.48

-10.09

0.00

0.00

16

16.67

-9.76

51.79

16.71

17

40.48

-16.98

0.00

0.00

18

10

16.69

141.85

0.16

0.00

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Arch Bridge Analysis using Finite Element Method


DESIGN CRITERIA
The concrete post-tensioned structural design is actually sections design, no matter box girder, circular column, or other sections.
There are three kind of forces on each section:
1. External loads, w only without P T , section forces. The External loads can be ASD level for serviceability design, or SD level for ultimate strength design.
2. Primary equivalent loads, P T section forces. The tendon is mentally removed and replaced with all of the loads it exerts on the structure.
3. Secondary section forces from all reactions of primary P T , on free-body structure.

INPUT DATA

DIMENSION

LL =

ft

Section

Ix (in4, in plane)
2791662

L=

130

ft

76

3507.84

ft

113

4307.04

7488499

H=

40

ft

200

6186.24

31119420

42.1008 kips / ft
(including bridge weight and impact factor.)

TENDON FORCE AFTER ALLOWANCE LOSSES


PT =

A (in2)

LR =

TOP DECK LOAD


w=

D (in)

8769.6

107

4177.44

6540969

84

3680.64

3584948

100

10800

9000000

80

8640

4608000

60

6480

1944000

MODULUS OF ELASTICITY

kips

E=

4030.509 ksi

ANALYSIS & DESIGN SUMMARY


Design Section Forces (Conservative Values)
External load reactions

External Load, w, Only

Section
P (kips, axial)

M (ft-kips)

V (kips, in plane)

'x (in)

'y (in)

RV =

662.69

kips

-21.96

0.00

-267.09

0.039

RH =

2025.85

kips

98.97

5024.89

511.92

0.032

-0.091

RN =

2284.37

kips

2208.63

-8426.23

-528.31

0.030

-0.096

2042.47

399.48

-222.21

0.023

-0.158

2042.47

4016.67

0.00

0.000

-0.199

3052.45

3136.35

-70.17

0.034

-0.097

RV =

-280.48

kips

3052.45

1568.18

-70.17

0.040

-0.074

RH =

178.11

kips

3052.45

0.00

-70.17

RN =

280.48

kips

Section

Primary equivalent loads, PT


P (kips, axial)

M (ft-kips)

Primary reactions

Secondary section forces from primary reactions

V (kips, in plane)

P (kips, axial)

M (ft-kips)

V (kips, in plane)

8763.09

0.00

-439.09

22.98

0.00

279.54

8663.40

8260.81

-1389.25

53.24

-5258.99

275.38

8703.67

31880.12

2075.49

173.25

-13429.48

41.31

8932.19

-2792.25

526.77

177.80

-14119.65

10.49

8932.19

-11367.14

0.00

177.80

-14290.34

0.00

326.72

2698.22

-60.37

326.72

2698.22

-60.37

326.72

1349.11

-60.37

326.72

1349.11

-60.37

326.72

0.00

-60.37

326.72

0.00

-60.37

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Masonry Shear Wall Design Based on TMS 402-08 / 2009 IBC (both ASD and SD)
INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
1
Yes
(This option only for local jurisdiction amendments to the code, not part of TMS.)
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
1
CMU
fm' =

MASONRY STRENGTH

ksi

REBAR YIELD STRESS


fy =
60
ALLOWABLE 30% INCREASING ? (TMS 2.1.2.3)
SEISMIC PERFORMANCE CATEGORY
D
( C,D,E, 0=WIND, 5=GRAVITY)

ksi
Yes
Seismic D

SERVICE AXIAL LOAD

P=

300

kips, at middle of L w

SERVICE SHEAR LOAD

Vx =

210

kips, (in-plane force)

SERVICE MOMENT LOAD

Mx =

6200

ft-kips, (top flange, bf1, compression)

My =

500

ft-kips, (out-of-plane, left b11 & b21, compression)

EFFECTIVE HEIGHT OF WALL

hw =

16

ft

LENGTH OF SHEAR WALL

Lw =

30

ft, (within vertical control joints)


THE WALL DESIGN IS ADEQUATE.

THICKNESS OF WALL
REINFORCING OF WALL

tw =

8
2

Ash, Horizontal

16

in o.c.

Asv, Vertical

24

in o.c.

b11 =

48

b21 =

36

TOP FLANGE (COMPRESSION)


tf 1 =

12

in ,

in ,

BOTTOM FLANGE
tf 2 =

in

in ,
5
in ,
5

at each ends, with

in center to edge.

b12 =

24

in ,

48

in o.c., Vertical

b22 =

48

in ,

48

in o.c., Vertical

bf 1 =

bf 2 =

80

in ,(TMS 1.9.4.2.3)

92

in, (TMS 1.9.4.2.3)

ANALYSIS
CHECK FLEXURAL & AXIAL CAPACITY BY ALLOWABLE STRESS DESIGN (ASD)

d

5000

d

4000

3000

2000

1000

0
0

5000

10000

15000

20000

25000

d

30000

-1000
d

P (k)

M (ft-k)
P (load) =

300

kips

M (resultant) = (Mx2 + My2)0.5 =


Where

<

P (allowable) = Pa =

6220.13 ft-kips

<

2069.56 kips

M (allowable) =

7571.53 ft-kips

Em =

2700

ksi, (TMS 1.8.2.2.1)

An =

4235

in2

Es =

29000

ksi, (TMS 1.8.2.1)

Ast =

9.94

in2

Scale Factor =

1.333

, (TMS 2.1.2.3)

[Satisfactory]

fs

ksi, (TMS 2.3.2.2.1)

Fb =

1.320

ksi, (TMS 2-17)

h/r=

87

, neglected conservatively flanges.

Fs =

32.00

ksi, (TMS 2.3.2.1)

Pa =

2069.56 kips, (TMS 2.3.3.2.1)

(cont'd)
CHECK FLEXURAL & AXIAL CAPACITY BY STRENGTH DESIGN (SD)

10000

8000

IPn (k)

6000

4000

2000

0
-10000

10000

20000

30000

40000

50000

60000

IMn (ft-k)

Pu = 1.2 P =

360

kips

Mu = (1/0.7) (Mx2 + My2)0.5 =


Where

-2000

8885.9

ft-kips

<
IMn =
[Satisfactory]

12763.3 ft-kips, at Pu level.

Hmu =

0.0025

, (TMS 3.3.2.c)

d=

363

in

I=

0.9

, (TMS 3.1.4.1)

fm' =

ksi

CHECK SHEAR CAPACITY (ASD)

1
M T ' , 80  45M T , for M T  1.0
SF MIN 4 
f

Vd m
Vd
Vd

SF MIN ( f ' , 35) , for M T t 1.0


m

Vd

Fv, without reinf.

1
MT
SF MIN 4 

Vd
2

SF MIN (1.5 f ' ,



m

Fv, Maximum

45M T
, 120 
,
Vd

75) , for M T t 1.0


Vd

'
m

48

psi

1.5 fv

<

(Shear reinf. reqd to carry full shear load.)


(factor 1.5 from TMS 402 1.17.3.2.6.1.2)

for M T  1.0
Vd

101

>

fv =

77

[Satisfactory]

CHECK MINIMUM REINFORCEMENTS

V
1.5

F sd
Ash,min =

0.33

in2 / ft

<

0.137

in2/ft

<

Ssh,max =

24

Asv,min =

0.064

Ssv,max =

24

Av
s

0.33

in2 / ft

[Satisfactory]

(TMS 402 1.17.3.2.6.1.2)

Ash,actual =

0.330

in2/ft

[Satisfactory]

(TMS 1.17.3.2.6)

in

>

Ssh,actual =

16

in

[Satisfactory]

(TMS 1.17.3.2.6)

in2/ft

<

Asv,actual =

0.220

in2/ft

[Satisfactory]

(TMS 1.17.3.2.6)

in

>

Ssv,actual =

24

in

[Satisfactory]

(TMS 1.17.3.2.6)

0.0003

[Satisfactory]

CHECK MAXIMUM REINFORCEMENT PERCENTAGE

U max

n f 'm

f
2 f y n  'y
f m

0.0087

>

U =

( TMS 402 2.3.3.4)

psi

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Masonry Shear Wall Design Based on TMS 402-08 / 2010 CBC (both ASD and SD)
INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
1
Yes
(This option only for local jurisdiction amendments to the code, not part of TMS.)
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
1
CMU
fm' =

MASONRY STRENGTH

ksi

REBAR YIELD STRESS


fy =
60
ALLOWABLE 30% INCREASING ? (TMS 2.1.2.3)
SEISMIC PERFORMANCE CATEGORY
D
( C,D,E, 0=WIND, 5=GRAVITY)

ksi
Yes
Seismic D

SERVICE AXIAL LOAD

P=

300

kips, at middle of L w

SERVICE SHEAR LOAD

Vx =

200

kips, (in-plane force)

SERVICE MOMENT LOAD

Mx =

6200

ft-kips, (top flange, bf1, compression)

My =

500

ft-kips, (out-of-plane, left b11 & b21, compression)

EFFECTIVE HEIGHT OF WALL

hw =

16

ft

LENGTH OF SHEAR WALL

Lw =

30

ft, (within vertical control joints)


THE WALL DESIGN IS ADEQUATE.

THICKNESS OF WALL
REINFORCING OF WALL

tw =

8
2

Ash, Horizontal

16

in o.c.

Asv, Vertical

24

in o.c.

b11 =

48

b21 =

36

TOP FLANGE (COMPRESSION)


tf 1 =

12

in ,

in ,

BOTTOM FLANGE
tf 2 =

in

in ,
5
in ,
5

at each ends, with

in center to edge.

b12 =

24

in ,

48

in o.c., Vertical

b22 =

48

in ,

48

in o.c., Vertical

bf 1 =

bf 2 =

80

in ,(TMS 1.9.4.2.3)

92

in, (TMS 1.9.4.2.3)

ANALYSIS
CHECK FLEXURAL & AXIAL CAPACITY BY ALLOWABLE STRESS DESIGN (ASD)

d

5000

d

4000

3000

2000

1000

0
0

5000

10000

15000

20000

25000

d

30000

-1000
d

P (k)

M (ft-k)
P (load) =

300

kips

M (resultant) = (Mx2 + My2)0.5 =


Where

<

P (allowable) = Pa =

6220.13 ft-kips

<

2027.82 kips

M (allowable) =

6699.19 ft-kips

Em =

2700

ksi, (TMS 1.8.2.2.1)

An =

4235

in2

Es =

29000

ksi, (TMS 1.8.2.1)

Ast =

6.66

in2

Scale Factor =

1.333

, (TMS 2.1.2.3)

[Satisfactory]

fs

ksi, (TMS 2.3.2.2.1)

Fb =

1.320

ksi, (TMS 2-17)

h/r=

87

, neglected conservatively flanges.

Fs =

32.00

ksi, (TMS 2.3.2.1)

Pa =

2027.82 kips, (TMS 2.3.3.2.1)

(cont'd)
CHECK FLEXURAL & AXIAL CAPACITY BY STRENGTH DESIGN (SD)

10000

8000

IPn (k)

6000

4000

2000

0
-10000

10000

20000

30000

40000

50000

60000

IMn (ft-k)

Pu = 1.2 P =

360

kips

Mu = (1/0.7) (Mx2 + My2)0.5 =


Where

-2000

8885.9

ft-kips

<
IMn =
[Satisfactory]

10200.8 ft-kips, at Pu level.

Hmu =

0.0025

, (TMS 3.3.2.c)

d=

363

in

I=

0.9

, (TMS 3.1.4.1)

fm' =

ksi

CHECK SHEAR CAPACITY (ASD)

1
M T ' , 80  45M T , for M T  1.0
SF MIN 4 
f

Vd m
Vd
Vd

SF MIN ( f ' , 35) , for M T t 1.0


m

Vd

Fv, without reinf.

1
MT
SF MIN 4 

Vd
2

SF MIN (1.5 f ' ,



m

Fv, Maximum

45M T
, 120 
,
Vd

75) , for M T t 1.0


Vd

'
m

47

psi

1.5 fv

<

(Shear reinf. reqd to carry full shear load.)


(factor 1.5 from TMS 402 1.17.3.2.6.1.2)

for M T  1.0
Vd

100

>

fv =

73

[Satisfactory]

CHECK MINIMUM REINFORCEMENTS

V
1.5

F sd
Ash,min =

0.31

in2 / ft

<

0.137

in2/ft

<

in
in2/ft

Ssh,max =

24

Asv,min =

0.064

Ssv,max =

24

A(sh+sv),min =

0.003

in
2

in /in

Av
s

0.33

in2 / ft

[Satisfactory]

(TMS 402 1.17.3.2.6.1.2)

Ash,actual =

0.330

in2/ft

[Satisfactory]

(TMS 1.17.3.2.6)

>

Ssh,actual =

16

in

[Satisfactory]

(TMS 1.17.3.2.6)

<

Asv,actual =

0.100

in2/ft

[Satisfactory]

(TMS 1.17.3.2.6)

>

Ssv,actual =

24

in

[Satisfactory]

(TMS 1.17.3.2.6)

[Satisfactory]

(CBC 10, 2106A.1.1.1.1.1)

<

A(sh+sv),actual =

0.005

in /in

0.0003

[Satisfactory]

CHECK MAXIMUM REINFORCEMENT PERCENTAGE

U max

n f 'm

f
2 f y n  'y
f
m

0.0087

>

U =

( TMS 402 2.3.3.4)

psi

!"# $

# %&

'

$*
F

()

()

+!'

,
- .$/

!+1

2,
$ .$/

0!

3 !

)
4

52

$/

5
#

2,
$ .$/

$/

)
4

27$

'

!;

)
4 <7 =/%)
>>,

'

!;

)
4<7 =/%)
>>,

4!
+ )

#
#

' # (&( )*(+ ,

+ ' 6!

# "
#

&

"
$%&

!#"

66'

>

-0
# "

63!

)
4

)
4

6'
!@

666
#

()

6 '';

()

?
++

2 )

6!

#
3+

! ;3
6;

1+6 )
4

2 )

$/

63

$/A,
- .$/

;6@

,
- .$/

1@3

,
- .$/

#
+
!6

@1 ,
- .$/
+
#

=,
,) )
47<%2D

$/A,
- .$/

,
- .$/

,
- .$/

!'

)
<4 =4>4</7D=7( >

=- ! !

)
B ! !A ! C 6 2=B

=,
,) 7D=7( >-E/ / ,) )
4 7<%2D

)
<4

!A!'

=,
,) 7D=7( >=4> / ,) )
4/4 )
<4
6

2 )

7<4/&
>
#

"

"

"

+!' $/A,
- .$/

+6 @ $/A,
- .$/

H </=22,
)
7=-, I

H </=22,
)
7=-, I

;;6

$/A,
- .$/ -

H </=22,
)
7=-, I

!;@

$/A,
- .$/ G

H =/)$=7/<D*I

5 %<% 4/%=*- ,
)
%)
/ >-* )
/5 D/5 %= <4D* 7<%2D

6'+

$/A,
- .$/

6'+

$/A,
- .$/

)
<4<D / ,/ 4 )
<4

H =/)$=7/<D*I

H </=22,
)
7=-, I

#
' +; 2 )

$J

H =/)$=7/<D*I

2=B

!A!'

%&'()%$

'*+)( ,- .*,(&/ '.&+()

.00 .*'1 ,(

! "#
!(

%&'

)*

%&'

)$

+
,& -!.

)3

4+
! -!.

- / 01

- / 01

5*

4+
! -!.
!.

/ 3 !.

"

'
6

9*

4:!

<

'
60: >. 8>:7 !>:8

<

$
/)

'
6 0: >. 8>:7 !>:8

&

* 9

'
6 -!.

.8

$ $3

'
6

"

,2

** '
6

3)9
9$*

$9*B*$9 9 9 $ 4>A8

'
6
%&'

@*** %&'

&

'
6/-!.

///

&

$.3%'&

'
6

74
8

/5

B$

-?,2 ***9$

***5

C >.'
&!>:.01(D

*** $

27818

$9*B*$ 9 9

$9*B*$9 9 9 $ >
***

$9*B*$9 9 9 $ >
)9

E
2

**$!"#

4&'

*$7 F 74

$*
!1

4&'

/$$

F 2

C >.'
&!>:.01(D
)$

+
,& -!.

5
5
!.B+
,&-!.
!

*@B*

4&'

+
,& -!.

$9*B*$ >, 9

,2 .8 -) !1

3$

".

$9*B*$ >, 9
!1

$9*B*$ 9 9 9 $ ?

$9*B*$9 9 $ /
F ! - A

27818

:1

%'
4&-!.

*) )*$

" # $

3B*$

+
,&-!.
E

>

H F & !( - *5*!"#,2

&8

F & !( -!(

*$

'
6

: >-*5*

6 -!.
* $ '

:1

'
6

6 &8 ?B: F ,:9 -9

6/-!.
*3 '

B
&.
H
H

$ :17 -/5 " A F $ H B :1 7 -/5 " :1


2H7 -5F H! 8- F H H

(:+
8

6? (:+
8

*
53*

91? (:+
8

'
6>+

933

95/

9**5

9**@

59
I :1
C >.'
&!>:.01(D

@@@
I J 9B9

44+
'
:>,+
8

'
6
!.B+
,&-!.

!" #

$%&

!" #

01!2!

&
!%

'

)*

$%&

" +
, %"
-

34

=$/"$

'

$..+
/$,+
!

2#(

*5*

6
*
&

21

%57 8 9 :

# +
!

&

%57 8 2
&* ;

<

&*7)

=$/"$
&

=$/"$

'

6 : 0

&;)

+
, %"

**

A == B = A == ?
$

'

'

&*35

/
" +
, %"

..+
/$,+
!

*& 5 &

D=
* 55

A EB

&

5
* 5 / %"

:, %

# +
!

&

&
21 %57 8 2

'

0'1 %7: '" !%& : ' '

&3 ;

<

=$/"$
!" #

$%&

!" #

'

&
!%

7)*

$%&

# +
!
*;

&;
2#(

/$+
*;*

*5
< >

&5

/
" +
, %"

..+
/$,+
!

" +
, %"
-

34

# +
!
* );

&

01!2!

)3&

)5 .+
" %"

&
21 %57 8 9 :

'

&*@ =

C A

&
&7 / %"

* 5 0*

'

; *;

66
0'

< >

$% 7

E=

"# %"#

/$+

)7)
&*3

2#(

"# % 7 "8 ,0

# +
!

2#(

* &: &=6=

)&7

&
7: " !%& :
!2 01 %

)1

# +
!

&

21

!2

=$/"$

'

$..+
/$,+
!

2#(

*5*

6
*
&
21 %57 8 9 :

!2

!2

# +
!

&

&
21 %57 8 2

&

01 %7: " !%& :

&* ;

<

=$/"$
)1
=

&

=$/"$

A
B
A

# +
!

)&7

&*7)
2#(

# +
!

/$+

)7)

)3&

&*3
< >

&*35

/
" +
, %"

..+
/$,+
!

2#(

5*&*
&&

8F "8
01!2!
7

;7

+
, %"

B'

* 5 0*1%& : 0& 1 :

1 1 %1 :

!%1(

=$/"$

6 E
'

=$/"$

2#(

2#(

)5

+
, %"

PROJECT :
PAGE :
CLIENT :
DESIGN BY :
JOB NO. :
DATE :
REVIEW BY :
Allowable Stress Design of Masonry Bearing Wall Based on TMS 402-08 / IBC 09
INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
=
MASONRY STRENGTH
fm'
fy

REBAR YIELD STRESS

1
1
1.5

Yes
CMU
ksi

60

ksi

SERVICE GRAVITY LOAD


SERVICE LATERAL LOAD
SERVICE PARAPET LOAD
THICKNESS OF WALL

P
w1
w2
t

=
=
=
=

Yes
625
26.7
80.2
8

PARAPET HEIGHT

hp

ft

WALL HEIGHT
ECCENTRICITY

h
e

=
=

20
6

ft
in

MASONRY SPECIFIC WEIGHT

130

pcf

WALL HORIZ. REINF.


WALL VERT. REINF.

1
1

#
#

5
5

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

lbs / ft
plf / ft
plf / ft
in

[THE WALL DESIGN IS ADEQUATE.]

@
@

16
16

in o.c. (at middle)


in o.c. (at middle)

ANALYSIS
VERT. REINF. AREA AT EACH SIDE
As
=
EFFECTIVE DEPTH (TMS 1.15.3.5)
d
=
=
WIDTH OF SECTION
bw
=
EFFECTIVE THICKNESS
te
MASONRY ELASTICITY MODULUS
Em
=
=
STEEL ELASTICITY MODULUS
Es
THE ALLOWABLE STRESS DUE TO FLEXURE IS

F b = ( SF ) 0.33 f

'
m

)=

660

0.23
3.82
12.00
7.63
1350
29000

in2
in
in
in
ksi
ksi

S = h+ hp

( h+h p )
2h

Pe

h w1

V 2 = h w1 V 1

= 10.5

1.05
Pe + w1 ( h 2 h 2p )
M1 =
2
2
2 w1h

ft

V 3 = h p w2

=
=

160

= 0.37059

32000 psi

THE GOVERNING MOMENTS AND AXIAL FORCES ARE

( h + h p ) w1 + Pe

2h

F S = (1.33 or 1.0 )( 24000 or 20000 ) =

psi

THE GOVERNING SHEAR FORCES ARE

V 1 = ( h + h p ) w1

k = 2n + ( n ) n

21.48
0.0051
1.333

THE ALLOWABLE REINF. STRESS DUE TO FLEXURE IS

THE DISTANCE FROM BOTTOM TO M1 IS


2

MODULAR RATIO
n =
REINFORCEMENT RATIO
=
ALLOWABLE STRESS FACTOR
SF =
THE NEUTRAL AXIS DEPTH FACTOR IS

280

lbs / ft

254 lbs / ft

P1 = P + ( wall weight ) =
2
w2h p
=
160
ft-lbs/ft
M2=
2

P 2 = P + ( wall weight )

1541

ft-lbs/ft

1623

lbs / ft

798

lbs / ft

THE GOVERNING SHEAR STRESS IN MASONRY IS

fv=

lbs / ft

MAX (V 1 , V 2 , V 3 )
t eb w

3.06

psi

DETERMINE THE REGION FOR FLEXURE AND AXIAL LOAD (MDG-3 Tab 12.2.1, Fig 12.2-12 & 13, page 12-25).

M
t
e
Pd 6 d
1. Wall is in compression and not cracked.

__
M
te 1

2d 3
Pd

2. Wall is cracked but steel is in compression.


REGION 2 APPLICABLE FOR (M2, P2)

Page 209 of 533


524

M
te 1
>

2d 3
Pd
3. Wall is cracked and steel is in tension.
REGION 3 APPLICABLE FOR (M1, P1)

(cont'd)
CHECK REGION 1 CAPACITY

Mm=

b wt e
te
Fb P =
6
6

6232 ft-lbs / ft

>

M1

[Not applicable]

6319 ft-lbs / ft

>

M2

[Not applicable]

CHECK REGION 2 CAPACITY


497

2P 2
te
=
Mm=P
2 3b w F b

ft-lbs / ft <

M1

[Not applicable]

249 ft-lbs / ft >


M2
[Satisfactory]
CHECK REGION 3 CAPACITY (The moment maybe limited by either the masonry compression or steel tension, MDG-3 page 12-25).

M m = MIN

kd
1
t
P d e
b wkd F b d
2
3
2

, AsF s d

1560

ft-lbs / ft

>

M1

[Satisfactory]

1560

ft-lbs / ft

>

M2

[Not applicable]

kd
t kd
+P e
3
2 3

THE ALLOWABLE SHEAR STRESS IS GIVEN BY

F v = ( SF ) MIN

'

f m , 50

51.64 psi

>

fv

[Satisfactory]

Technical References:
1. "Masonry Designers' Guide, Third Edition" (MDG-3), The Masonry Society, 2001.

__
Page 210 of 533
524

PROJECT :
CLIENT :
JOB NO. :
DATE :
Strength Design of Masonry Bearing Wall Based on TMS 402-08 / IBC 09

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


TYPE OF MASONRY ( 1=CMU, 2=BRICK )
=
MASONRY STRENGTH
fm'
=
REBAR YIELD STRESS
fy
SERVICE DEAD LOAD
PDL
=
=
LATERAL LOAD (E/1.4 or W)
w1
=
LATERAL LOAD (E/1.4 or W)
w2
THICKNESS OF WALL
t
=
=
PARAPET HEIGHT
hp
WALL HEIGHT
h
=
ECCENTRICITY
e
=

CMU
ksi
ksi
lbs / ft
plf / ft
plf / ft
in
ft
ft
in

130

2
2
SDS

#
#
=

5
5
1.246

@
@

As

0.23

in2/ft

EFFECTIVE THICKNESS

5.57

in

MASONRY ELASTICITY MODULUS

bw

12.00

in

STEEL ELASTICITY MODULUS

Ig

444

in4/ft

MODULAR RATIO

MASONRY SPECIFIC WEIGHT


WALL HORIZ. REINF.
WALL VERT. REINF.
SEISMIC PARAMETER

1
1.5
60
625
26.7
80.2
8
2
24.17
6

pcf

[THE WALL DESIGN IS ADEQUATE.]


16
16

in o.c. (at each face)


in o.c. (at each face)

ANALYSIS
VERT. REINF. AREA AT EA. SIDE

EFFECTIVE DEPTH
WIDTH OF SECTION
GROSS MOMENT OF INERTIA

te =

7.63

in

Em =

1350

ksi

Es =

29000 ksi

21.48

CHECK REINFORCING RATIO (TMS 402-08 3.3.3.5, page CC-61)


P
mu

bd
mu + y

'

0.64 f m

= As / d bw = 0.0035

<

fy

MAX =

'

0.64 f m

[Satisfactory]

for bars middle

P
mu

bd
mu + y

for bars each face

d'
+ y , y E s
f y min mu

d mu

where

mu

0.0025

, (TMS 402-08 3.3.2 c)

1.5

, (TMS 402-08 3.3.3.5.1 a)

= fy / Es =

= D + 0.75 L + 0.525 Q E =

0.0082

0.0021 , (TMS 402-08 3.3.3.5.1 a)


2.63

kips/ ft, (TMS 402-08 3.3.3.5.1 d)

75

psi

CHECK WALL AXIAL STRESS (TMS 402-08 3.3.5.3)


1.2 (Pw + Pf) / Ag = 24.2 psi
where

Pw =

0.05 fm' =

<

(0.5 h + hp) m t =

1221

[Satisfactory]
Pf =

lbs / ft ,

625

lbs / ft

DETERMINE CRACKING MOMENT (TMS 402-08 Tab 3.1.8.2)


fr =

150

psi, (TMS 402-08 Tab 3.1.8.2)

Mcr = S fr = (bw te2 / 6) fr =

1455

ft-lbs/ft

CHECK CAPACITY OF LOAD COMBINATION (0.9 - 0.2SDS) D + Eh , (IBC 09 1605.2.1 & ASCE 7-05 12.4.2)
Pu = (0.9 - 0.2SDS) (PDL + Pw) =

1201

lbs/ft

DEPTH OF THE COMPRESSIVE STRESS BLOCK


a = (Pu + As fy) / (0.80 fm' bw) =

1.05

DEPTH OF NEUTRAL AXIS


in

c = a/ 0.80 =

__

EFFECTIVE AREA OF REINFORCING STEEL


2
Ase = (Pu + As fy) / fy =
0.25 in /ft

u = 5Mcrh2/(48EmIg) + 5(Mu - Mcr)h2/(48EmIcr) =


Mu = wuh /8 + Puf e/2 + Puu =

in

4
Icr = n Ase(d-c)2 + bc3 / 3 = 107 in /ft

THE MOMENT AND DEFLECTION AT THE MID-HEIGHT OF THE WALL ARE GIVEN BY
1st Cycle
2nd Cycle
2

1.32

CRACKED MOMENT OF INERTIA

2870

> Mcr

[Satisfactory]

Page 211 of 533


524

1.283
2999

3rd Cycle

Final

1.377

1.384

in

3008

3009

ft-lbs/ft

=> Eq (3-32) Applicable

(cont'd)
CHECK MOMENT CAPACITY OF THE WALL (TMS 402-08 3.3.5)
Mn = [Asefy(d-a/2) - Pu(d-te/2)] =

5571

Mn = Asefy(d-a/2) =

ft-lbs/ft

>

<= Not applicable

Mu

[Satisfactory]

where f = 0.9, (TMS 402-08 3.1.4.1)


CHECK DEFLECTION LIMITATION (TMS 402-08 3.3.5.4)
1st Cycle

2nd Cycle

0.728

s = 5Mcrh2/(48EmIg) + 5(Mser - Mcr)h2/(48EmIcr) =


2

Mser = wh /8 + Pf e/2 + Ps =

2106

> Mcr

2.03

in

>

Final

0.787

0.792

in

2193

2194

ft-lbs/ft

2187

[Satisfactory]
0.007 h =

3rd Cycle

=> Eq (3-32) Applicable

[Satisfactory]

CHECK CAPACITY OF LOAD COMBINATION (1.2 + 0.2SDS) D + Eh , (IBC 09 1605.2.1 & ASCE 7-05 12.4.2)
Pu = (1.2+0.2SDS)(PDL + Pw) =

2675

lbs/ft

DEPTH OF THE COMPRESSIVE STRESS BLOCK


a = (Pu + As fy) / (0.80 fm' bw) =

1.15

DEPTH OF NEUTRAL AXIS


in

c = a/ 0.80 =

EFFECTIVE AREA OF REINFORCING STEEL


2
Ase = (Pu + As fy) / fy =
0.28 in /ft

1.44

in

CRACKED MOMENT OF INERTIA


4
Icr = n Ase(d-c)2 + bc3 / 3 = 104 in /ft

THE MOMENT AND DEFLECTION AT THE MID-HEIGHT OF THE WALL ARE GIVEN BY
wu = 1.4 w1 =

37.4 plf / ft
1st Cycle

2nd Cycle

1.376

1.605

1.651

in

3263

3314

3324

ft-lbs/ft

u = 5Mcrh2/(48EmIg) + 5(Mu - Mcr)h2/(48EmIcr) =


Mu = wuh2/8 + Puf e/2 + Puu =

2956

> Mcr
[Satisfactory]

3rd Cycle

Final

=> Eq (3-32) Applicable

CHECK MOMENT CAPACITY OF THE WALL (TMS 402-08 3.3.5)


Mn = [Asefy(d-a/2) - Pu(d-te/2)] =

5871

Mn = Asefy(d-a/2) =

ft-lbs/ft

>

<= Not applicable

Mu

[Satisfactory]

where f = 0.9, (TMS 402-08 3.1.4.1)


CHECK DEFLECTION LIMITATION (TMS 402-08 3.3.5.4)
s = 5Mcrh2/(48EmIg) + 5(Mser - Mcr)h2/(48EmIcr) =
2

Mser = wh /8 + Pf e/2 + Ps =

1st Cycle

2nd Cycle

0.728

2106

> Mcr
[Satisfactory]

0.007 h =

2.03

in

>

2187

3rd Cycle

Final

0.787

0.792

in

2193

2194

ft-lbs/ft

704

lbs/ft

=> Eq (3-32) Applicable

[Satisfactory]

CHECK SHEAR CAPACITY (TMS 402-08 3.3.4.1.2.1)


Vn = 2.25 Amv (fm')0.5 =

6383

lbs/ft

>

Vu = 1.4 [w1h/2 + w2(h + 0.5hP)hP/h + PDLe/h] =

where = 0.8

[Satisfactory]

CHECK PARAPET BENDING CAPACITY


Mn

>

Mu

[Satisfactory]

__
Page 212 of 533
524

PROJECT :
CLIENT :
JOB NO. :
DATE :
Design for Girder at Masonry Wall Based on TMS 402-08

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


SPECIAL INSPECTION ( 0=NO, 1=YES )
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
MASONRY STRENGTH
fm'
=
REBAR YIELD STRESS
fy
=
GIRDER SERVICE LOAD
ECCENTRICITY

PG
e

=
=

1
1
1.5
60
Yes
32
3

BEARING LENGTH

Lbr

20

in

SERVICE LATERAL LOAD


SERVICE PARAPET LOAD
THICKNESS OF WALL
PARAPET HEIGHT
WALL HEIGHT

w1
w2
t
hp
h

=
=
=
=
=

25
45
8
2
15

psf
psf
in
ft
ft

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

WALL VERT. REINF. (Asv)


@
16

Yes
CMU
ksi
ksi
kips
in

2
#
7
in o.c. (at each face)

[THE WALL DESIGN IS ADEQUATE.]

ANALYSIS
te

EFFECTIVE THICKNESS

7.63

in

EFFECTIVE LENGTH (TMS 402, 1.9.5)


Le =2 Lbr =

40.00

in

LOAD DISTRIBUTION (TMS 402 1.9.7)


=
8533
P = PG / (0.25 h)
CHECK BEARING CAPACITY (TMS 402, 2.1.8)
fbr = PG / (te Lbr)

=
0.25 fm' =

<

210

psi

375

psi

[Satisfactory]
REINF. AREA AT EACH SIDE
As
=
EFFECTIVE DEPTH (TMS, 1.15.3.5)
d
=
=
WIDTH OF SECTION
bw
MASONRY ELASTICITY MODULUS
Em
=
STEEL ELASTICITY MODULUS
Es
=
MODULAR RATIO
n
=
THE ALLOWABLE STRESS DUE TO FLEXURE IS

F b = ( SF ) 0.33 f

'
m

)=

660

lbs / ft

0.45
5.44
12.00
1350
29000
21.48

S = h+ hp

( h+h p )
2h

Pe

h w1

in
in
ksi
ksi

REINFORCEMENT RATIO
=
ALLOWABLE STRESS FACTOR
SF =
THE NEUTRAL AXIS DEPTH FACTOR IS

k = 2n + ( n ) n
2

0.0069
1.333

= 0.41584

THE ALLOWABLE REINF. STRESS DUE TO FLEXURE IS

F S = (1.33 or 1.0 )( 20000 or 24000 ) =

psi

THE DISTANCE FROM BOTTOM TO M1 IS


2

in2

32000 psi

THE GOVERNING MOMENTS AND AXIAL FORCES ARE

M1 =

__

= 13.1

ft

2 w1h 2

Pe+ w1 ( h 2 h2p )
2

P1 = P + ( wall weight )

Page 213 of 533


524

2131
8875

ft-lbs/ft
lbs / ft

(cont'd)
THE GOVERNING SHEAR FORCES ARE

V 1 = ( h + h p ) w1

( h + h p ) w1 + Pe

2h

V 2 = h w1 V 1

V 3 = h p w2

M2=

326

lbs / ft

49

90

lbs / ft

lbs / ft

90

ft-lbs/ft

P 2 = P + ( wall weight )

w2h
2

2
p

8707

lbs / ft

THE GOVERNING SHEAR STRESS IN MASONRY IS

fv=

MAX (V 1 , V 2 , V 3 )
t eb w

3.56

psi

DETERMINE THE REGION FOR FLEXURE AND AXIAL LOAD (MDG-3 Tab 12.2.1, Fig 12.2-12 & 13, page 12-25).

M
te 1

2d 3
Pd

M
t
e
Pd 6 d
1. Wall is in compression and not cracked.

M
te 1
>

2d 3
Pd

2. Wall is cracked but steel is in compression.

3. Wall is cracked and steel is in tension.


REGION 3 APPLICABLE FOR (M1, P1)

REGION 1 APPLICABLE FOR (M2, P2)

CHECK REGION 1 CAPACITY


2

b wt e
te
Mm=
Fb P =
6
6

5463

ft-lbs / ft

>

M1

[Not applicable]

5481

ft-lbs / ft

>

M2

[Satisfactory]

M1

[Not applicable]

CHECK REGION 2 CAPACITY


2269

2P 2
te
=
Mm=P
2 3b w F b

ft-lbs / ft >

ft-lbs / ft >
M2
[Not applicable]
2236
CHECK REGION 3 CAPACITY (The moment maybe limited by either the masonry compression or steel tension, MDG-3 page 12-25).

M m = MIN

kd
1
t
P d e
b wkd F b d
2
3
2

, AsF s d

2298

ft-lbs / ft

>

M1

[Satisfactory]

2321

ft-lbs / ft

>

M2

[Not applicable]

kd
t kd
+P e
3
2 3

CHECK ALLOWABLE SHEAR STRESS (TMS 402 2.3.5.2.2)

F v = ( SF ) MIN

'
m

, 50

51.64 psi

>

fv

[Satisfactory]

Technical References:
1. "Masonry Designers' Guide, Third Edition" (MDG-3), The Masonry Society, 2001.

__
Page 214 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Masonry Beam Design Based on TMS 402-08


INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
=
MASONRY STRENGTH
fm'
=
REBAR YIELD STRESS
fy

0
1
1.5
60

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

Yes

SERVICE SHEAR LOAD


SERVICE MOMENT LOAD
WIDTH
EFFECTIVE DEPTH
CLEAR SPAN

V
M
b
d
Lc

=
=
=
=
=

4.56
13.68
8
45
12
1
@
#

LOAD TYPE (1=SEISMIC, 0=WIND, 5=GRAVITY)

VERTICAL REINF.
1
TENSION REINFORCEMENT

No, (reduced fm' by 0.5)


CMU
ksi
ksi

4
2

k
ft-k
in
in
ft
Seismic
8
in o.c.
6

[THE BEAM DESIGN IS ADEQUATE.]

ANALYSIS
ALLOWABLE STRESS FACTOR

SF

ALLOWABLE REINF. STRESS


(1.33 or 1.0) Fs
ALLOWABLE MASONRY STRESS
Fb=(SF)(0.33fm')
MASONRY ELASTICITY MODULUS
Em
STEEL ELASTICITY MODULUS
Es
EFFECTIVE WIDTH
bw
MODULAR RATIO
n
TENSION REINFORCEMENT RATIO

=
=
=
=
=
=
=

0.667
32
0.33
1350
29000
7.63
21.48
0.003

ksi
ksi
ksi, (TMS 402 1.8.2.2.1)
ksi, (TMS 402 1.8.2.1)
in
[Satisfactory, Lc < 32 bw]

THE NEUTRAL AXIS DEPTH FACTOR IS

k = 2n + ( n ) n

THE LEVER-ARM FACTOR IS

j = 1

0.281

k
3

= 0.906

THE TENSILE STRESS IN REINFORCEMENT DUE TO FLEXURE IS

M
A s jd

fs=

4.57

ksi

<

[SATISFACTORY]

Fs

THE COMPRESSIVE STRESS IN THE EXTREME FIBER DUE TO FLEXURE IS

fb=

2M
jk b w d 2

0.08

ksi

<

[SATISFACTORY]

Fb

THE SHEAR STRESS IN MASONRY IS


<

V
fv=
b wd

13

(Sec. 2.3.5.2.1)

F v = ( SF ) MIN (

psi

'
m

, 50) =

25.82 psi

[SATISFACTORY]
<

F v = ( SF ) MIN (3 f

'
m

__

, 150) =

77.46 psi

CHECK THE MINIMUM AREA OF SHEAR REINFORCEMENT REQUIRED :

V
F sd

0.04

2
in / ft

<

Av =
s

0.30

Page 215 of 533


524

in2 / ft

( No shear reinf. Reqd )

[SATISFACTORY]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Masonry Beam Design Based on UBC 97


INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
=
MASONRY STRENGTH
fm'
=
REBAR YIELD STRESS
fy

1
1
1.5
60

ALLOWABLE INCREASING ? (UBC/CBC 1612.3.2)

Yes

SERVICE SHEAR LOAD


SERVICE MOMENT LOAD
WIDTH
EFFECTIVE DEPTH
CLEAR SPAN

15.1
83
12
40
12
5
@
#

V
M
b
d
Lc

=
=
=
=
=

LOAD TYPE (1=SEISMIC, 0=WIND, 5=GRAVITY)

VERTICAL REINF.
1
TENSION REINFORCEMENT

4
2

Yes, (Sec. 2107.1.2)


CMU
ksi
ksi
k
ft-k
in
in
ft
Gravity Only
8
in o.c.
7

[THE BEAM DESIGN IS ADEQUATE.]

ANALYSIS
SF

1.333

ALLOWABLE REINF. STRESS


(1.33 or 1.0) Fs
ALLOWABLE MASONRY STRESS
Fb=(SF)(0.33fm')
MASONRY ELASTICITY MODULUS
Em
STEEL ELASTICITY MODULUS
Es
EFFECTIVE WIDTH
bw
MODULAR RATIO
n
TENSION REINFORCEMENT RATIO

=
=
=
=
=
=
=

32
ksi
0.66
ksi
750 fm' =
1125
29000 ksi
11.63 in
25.78
0.0026

ALLOWABLE STRESS FACTOR

ksi, (Eq. 6-4. 2106.2.12.1)


[Satisfactory, Lc < 32 bw]

THE NEUTRAL AXIS DEPTH FACTOR IS

k = 2n + ( n ) n

THE LEVER-ARM FACTOR IS

j = 1

0.304

k
3

= 0.899

THE TENSILE STRESS IN REINFORCEMENT DUE TO FLEXURE IS

M
A s jd

fs=

23.09 ksi

<

[SATISFACTORY]

Fs

THE COMPRESSIVE STRESS IN THE EXTREME FIBER DUE TO FLEXURE IS

fb=

2M
jk b w d 2

0.39 ksi

<

[SATISFACTORY]

Fb

THE SHEAR STRESS IN MASONRY IS


<

V
fv=
jb wd

36

(Sec. 2107.2.17)

F v = ( SF ) MIN (

'
m

, 50) =

51.64 psi

[SATISFACTORY]

psi
<

F v = ( SF ) MIN (3 f

'
m

__

, 150) =

154.92 psi

CHECK THE MINIMUM AREA OF SHEAR REINFORCEMENT REQUIRED :

V
F sd

0.14

2
in / ft

<

Av =
s

0.30

Page 216 of 533


524

in2 / ft

( No shear reinf. Reqd )

[SATISFACTORY]

"#
!

()

)* +

"#$

'
1

"&
H

230
4&

5
'

7'

8+

"49.

' 15 0
:

((

((

((

' 15 0
:

(
-

./0
./0

6
) )

'

1 '5+

'

"#$%&

)*

'

>?/ <

"4

'5

<

0
:

$%

&'

5 0
:

55'

)*

'#
(

((

*)
((

) )

:+
5 1 0

+@@

* *

@'
)
)

* *

,
/

5'
+7

5 1

0
:+

*
(

) 6

./0

+ @8

11B

5
(

0
:

:
)

1 ' 5+

'5 +
+' :

1@
1

0
:+

+,

7 BB

0
:+

+,

*
*

( -

*)

./0

5B ./0
- . /$

) )

6*

) 6

) )

) 6

+,

D(

, ,0 *

6*

D(

+'1

./0

- .1/$
6

+,

( -

+,

5+

./0

78

0
:@

6*

*)
'5 @5' .

- . /$
6

+,

)
1'

) - (

/$

+,

6
+' 8+ E/0
3

+) 4

! + 5'+

BB @1 E/0

+5

!;:0
!2>

0
:+ F"4

0
:+ F"4

+,

" :! /

G)2/ : &

/0
?: /$

;0

0
40:G )

95

; )2/ : &

!04& +

)5
$

6*

8 ./0
- + /$

0
:

:+
5BB 0

6
+5

#2C

*)

./0

@ :
*

0
:+

:@
@7B5 0

+,

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Masonry Column Design Based on CBC 10 Chapter A


INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
1
Yes
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
1
CMU
=
1.5
ksi
MASONRY STRENGTH
fm'
REBAR YIELD STRESS
fy
=
60
ksi
SEISMIC DESIGN CATEGORY
4
E or F
( 1 = B, 2 = C, 3 = D, 4 = E or F, 0 = WIND, 5 = GRAVITY)
SERVICE AXIAL LOAD
P
=
11.5 k, @ top of col.
MAX SHEAR LOAD
V
=
20
k
MOMENT AT MIDHEIGHT
M
=
106
ft-k, @ mid of col
EFFECTIVE WIDTH
b
=
23.63 in
EFFECTIVE DEPTH
c
=
23.63 in
DISTANCE BETWEEN COL. REINF.
a=
EFFECTIVE HEIGHT
h
=
29
ft
(ACI 530, 1.13.3.5)
VERTICAL REINF. (EACH SIDE)
3
#
8
legs # 4
@
8
in o.c.
[THE COLUMN DESIGN IS ADEQUATE.]
HORIZ. TIES
2

19.13

in

0.005
21.38
1.333

in

in

ANALYSIS
REINFORCEMENT AREA AT ONE SIDE

EFFECTIVE COLUMN AREA


NET EFFECTIVE MOMENT OF INERTIA

As
An
In

=
=
=

RADIUS OF GYRATION

6.82

Em
Es
n

=
=
=

At = An(1-+n+n' )

1350 ksi
29000 ksi
21.48
2
668 in

MASONRY ELASTICITY MODULUS


STEEL ELASTICITY MODULUS
MODULAR RATIO
TRANSFORMED AREA

2
2.37 in
2
558 in
4
25982 in

in

0.04Ae = 0.04bd =

h
1.0
140r

ALLOWABLE REINF. STRESS DUE TO FLEXURE

F S = (1.33wind & seismic only ) ( 20 or 24 ) =

FS =
ES

32.0

ksi

STRESS IN THE EXTREME FIBER DUE TO MT


0.574

ksi

< Fb', [Satisfactory]

STRAIN IN THE COMPRESSION BARS


'
eS =

kd d
em =
kd
'

0.278
0.907

[Satisfactory]

[Satisfactory]

Pd
=
2

107.1 ft-kips

P t = P + ( full col. weight ) =

26.681 k

245.71 k
[for h/r < 99]

> Pt, [Satisfactory]

P Mid
'
F b = SF
Pa

( 0.33 f ) =
'
m

0.622

ksi

THE STRAIN IN THE EXTREME COMPRESSION FIBER IS


'
kd
Fb
es ,
d kd
Em

0.0004253
(steel governs)

MOMENT DUE TO THE MASONRY

Mm=

kd
1
bkd f b (d ) =
2
3

65.21

STRESS IN THE COMPRESSION BARS

f S = 2 E S e 'S =
'

0.0002644

=
=

AXIAL LOAD AT BASE OF THE COLUMN

e m = MIN

0.0011

f b = em E m =

in

j = 1-k/3

ALLOWABLE STRESS DUE TO FLEXURE

THE CORRESPONDING STRAIN IN THE TENSILE BARS IS

eS =

in2

2.53

M Mid = M + ( 0.1)

19.090 k

CHECK IF THERE IS TENSILE STRESS IN CROSS SECTION


<
34
psi
MMid / (bc2/6) =
585 psi
PMid / A =
(tensile exist)
ALLOWABLE AXIAL LOAD FOR AXIAL COMPRESSION ONLY

LEVER-ARM FACTOR

TOTAL MOMENT ACTING AT MIDHEIGHT

P Mid = P + ( half col. weight ) =

P a = 0.25 f An + 0.65 F S A st

NEUTRAL AXIS DEPTH FACTOR


k = {[n+(2n-1)' ]2+2[n+(2n-1)(d'/d)]}0.5 - [n+(2n-1)' ]

20.21

AXIAL LOAD AT MIDDLE OF THE COLUMN

'
m

Smax

MAX. TIES SPACING (2106A.5.3.2)

CHECK VERTICAL REINFORCEMENT LIMITATION (ACI 530, 2.1.6.4)


2
As,total =
> 0.005Ae = 0.005bd =
4.74 in
<

= ' =
REINFORCEMENT RATIO
DISTANCE
d' = 2.25 , d =
ALLOWABLE STRESS FACTOR
SF =

15.334

ksi

ft-kips

(cont'd)
MOMENT DUE TO THE COMPRESSION BARS
'
'
M S = f S AS (d d ) =

ALLOWABLE BENDING MOMENT

M =M S + M m =

'

57.94

'

ft-kips

123.15 ft-kips
> Mt, [Satisfactory]

SHEAR DESIGN DETERMINED FROM THE FOLLOWING EXPRESSION

V
fv=
jbd

39

(Sec. 2107.2.17)

V
F sd

0.32

in2 / ft

psi

<

'
F v = ( SF ) MIN ( f m , 50) =

51.64 psi

[Satisfactory]
<

<

'
F v = ( SF ) MIN (3 f m , 150) =

Av =
s

0.60

in2 / ft

154.92 psi

( No shear reinf. Reqd )

Technical References:
1. "Masonry Designers' Guide, Third Edition" (MDG-3), The Masonry Society, 2001.

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Masonry Column Design Based on TMS 402-08 / IBC 09


INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
=
MASONRY STRENGTH
f m'
=
REBAR YIELD STRESS
fy

0
1
1.5
60
Yes
2
50
9.5
8.2
15.63
15.63
15
#
@

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

SEISMIC DESIGN CATEGORY (5=Gravity)


SERVICE AXIAL LOAD
P
=
SERVICE SHEAR LOAD
V
=
MOMENT AT MIDHEIGHT
M
=
EFFECTIVE WIDTH
b
=
EFFECTIVE DEPTH
d
=
EFFECTIVE HEIGHT
h
=
VERTICAL REINF. (EACH SIDE)
2
HORIZ. TIES
2
legs # 4

No, (reduced fm' by 0.5)


CMU
ksi
ksi
C
k
k
ft-k
in
in
ft

DISTANCE BETWEEN COL. REINF.


(TMS 402, 1.15.3.5)
6
8

in o.c.

a=

11.38

in

[THE COLUMN DESIGN IS ADEQUATE.]

ANALYSIS
TOTAL REINFORCEMENT AREA

As

1.76

in

EFFECTIVE COLUMN AREA

An

244

in

In

4
4973 in

ALLOWABLE STRESS FACTOR

4.51

MAX. TIES SPACING (1.17.4)

MASONRY ELASTICITY MODULUS

Em

1350 ksi

STEEL ELASTICITY MODULUS

Es

29000 ksi

NET EFFECTIVE MOMENT OF INERTIA


RADIUS OF GYRATION

in

MODULAR RATIO

21.48

REINFORCEMENT RATIO

0.007

SF

0.667

Smax

16

At = An (1 + ( 2n 1) ) =

CHECK VERTICAL REINFORCEMENT LIMITATION (TMS 402 1.14.1.2)


2
in2
As =
1.76 in
0.61
> 0.0025An =
<

0.04An =

in

9.77

ALLOWABLE STRESS DUE TO AXIAL LOAD ONLY

h
140r

F a = ( SF ) 0.25 f m 1.0
'

'

M T = M + ( 0.1)

M Td =
2I t

0.163

32.0

ksi

I t = I n + ( 2n 1) As

11.5 ft-kips

a
2

7365

in

MAX.STRESS COMBINED AXIAL & FLEXURE

f m = f a+ f b =

0.308 ksi
< Fb, [Satisfactory]

AXIAL LOAD AT BASE OF THE COLUMN

P t = P + ( full col. weight ) =

11.5 ksi
< Fs, [Satisfactory]

53.435 k

ALLOWABLE AXIAL LOAD FOR AXIAL COMPRESSION ONLY

Pa =

( ( SF ) 0.25 f

'
m

An + 0.65 F S A S

1.0

h
140r

89.75 k
[for h/r < 99]

> Pt, [Satisfactory]

SHEAR DESIGN DETERMINED FROM THE FOLLOWING EXPRESSION

V
fv=
bd

39

(TMS 402 2.3.5.2.1)

V
F sd

0.23

psi

>

'
F v = ( SF ) MIN ( f m , 50) =

25.82 psi

(Shear reinf. reqd to carry full shear load.)

__

in / ft

ksi

TRANSFORMED MOMENT OF INERTIA

0.146 ksi
< fa, [Satisfactory, the section is uncracked]

af b
=
d

At

F S = (1.33 or 1.0 )( 20 or 24 ) =

MAX. REINF. STRESS COMBINED AXIAL & FLEXURE

f S = 2n f a +

P + ( half col . weight )

< Fa, [Satisfactory]


ALLOWABLE REINF. STRESS DUE TO FLEXURE

STRESS IN THE EXTREME FIBER DUE TO MT

fb=

[Satisfactory]

fa=

0.230 ksi

TOTAL MOMENT ACTING AT MIDHEIGHT

Pd
=
2

[Satisfactory]

ksi

0.330

318 in

AXIAL STRESS AT MIDHEIGHT OF THE COLUMN

[for h/r < 99]


ALLOWABLE STRESS DUE TO FLEXURE

F b = ( SF ) 0.33 f m =

in

TRANSFORMED COLUMN AREA

<

<

'
F v = ( SF ) MIN (3 f m , 150) =

Av =
s

0.60

in / ft

[Satisfactory]

Technical References:
1. "Masonry Designers' Guide, Third Edition" (MDG-3), The Masonry Society, 2001.

Page 220 of 533


524

77.46 psi

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Masonry Column Design Based on TMS 402-08 / IBC 09


INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
1
Yes
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
1
CMU
=
1.5
ksi
MASONRY STRENGTH
fm'
REBAR YIELD STRESS
fy
=
60
ksi
SEISMIC DESIGN CATEGORY
4
E or F
( 1 = B, 2 = C, 3 = D, 4 = E or F, 0 = WIND, 5 = GRAVITY)
SERVICE AXIAL LOAD
P
=
11.5 k, @ top of col.
MAX SHEAR LOAD
V
=
20
k
MOMENT AT MIDHEIGHT
M
=
106
ft-k, @ mid of col
EFFECTIVE WIDTH
b
=
23.63 in
EFFECTIVE DEPTH
c
=
23.63 in
DISTANCE BETWEEN COL. REINF.
a=
EFFECTIVE HEIGHT
h
=
29
ft
(TMS 402, 1.15.3.5)
VERTICAL REINF. (EACH SIDE)
3
#
8
legs # 4
@
8
in o.c.
[THE COLUMN DESIGN IS ADEQUATE.]
HORIZ. TIES
2

19.13

in

ANALYSIS
As
An
In
r
Em
Es
n

=
=
=
=
=
=
=

TRANSFORMED AREA At = An(1-+n+n' )

REINFORCEMENT AREA AT ONE SIDE

EFFECTIVE COLUMN AREA


NET EFFECTIVE MOMENT OF INERTIA

RADIUS OF GYRATION
MASONRY ELASTICITY MODULUS
STEEL ELASTICITY MODULUS
MODULAR RATIO

in2
in2
in4

2.37
558
25982
6.82
1350

in
ksi
29000 ksi
21.48
2
668 in

= ' =
REINFORCEMENT RATIO
0.005
DISTANCE
d' = 2.25 , d = 21.38 in
ALLOWABLE STRESS FACTOR
SF =
1.333
8
in
MAX. TIES SPACING (1.17.4)
Smax =
NEUTRAL AXIS DEPTH FACTOR
k = {[n+(2n-1)' ]2+2[n+(2n-1)(d'/d)]}0.5 - [n+(2n-1)' ]
LEVER-ARM FACTOR

CHECK VERTICAL REINFORCEMENT LIMITATION (TMS 402 1.14.1.2)


2
As,total =
4.74 in
2.53
> 0.005Ae = 0.005bd =
<

0.04Ae = 0.04bd =

20.21

AXIAL LOAD AT MIDDLE OF THE COLUMN

P a = 0.25 f m An + 0.65 F S A st 1.0

h
140r

ALLOWABLE REINF. STRESS DUE TO FLEXURE

F S = (1.33wind & seismic only ) ( 20 or 24 ) =

FS =
ES

32.0

ksi

STRESS IN THE EXTREME FIBER DUE TO MT


0.574

ksi

< Fb', [Satisfactory]

STRAIN IN THE COMPRESSION BARS


'
eS =

kd d
em =
kd
'

Pd
=
2

107.1 ft-kips

P t = P + ( full col. weight ) =

26.681 k

245.71 k
[for h/r < 99]

> Pt, [Satisfactory]

P Mid
'
F b = SF
Pa

( 0.33 f ) =
'
m

0.622

ksi

THE STRAIN IN THE EXTREME COMPRESSION FIBER IS


'
kd
Fb
es ,
d kd
Em

0.0004253
(steel governs)

MOMENT DUE TO THE MASONRY

Mm=

kd
1
bkd f b (d ) =
2
3

65.21

STRESS IN THE COMPRESSION BARS

f S = 2 E S e 'S =
'

0.0002644

0.907

AXIAL LOAD AT BASE OF THE COLUMN

e m = MIN

0.0011

f b = em E m =

[Satisfactory]

ALLOWABLE STRESS DUE TO FLEXURE

THE CORRESPONDING STRAIN IN THE TENSILE BARS IS

eS =

[Satisfactory]

in2

M Mid = M + ( 0.1)

19.090 k

CHECK IF THERE IS TENSILE STRESS IN CROSS SECTION


<
34
psi
MMid / (bc2/6) =
585 psi
PMid / A =
(tensile exist)
ALLOWABLE AXIAL LOAD FOR AXIAL COMPRESSION ONLY

in2

0.278

TOTAL MOMENT ACTING AT MIDHEIGHT

P Mid = P + ( half col. weight ) =

'

j = 1-k/3

15.334

ksi

ft-kips

(cont'd)
MOMENT DUE TO THE COMPRESSION BARS
'
'
M S = f S AS (d d ) =

ALLOWABLE BENDING MOMENT

M =M S + M m =

'

57.94

'

ft-kips

123.15 ft-kips
> Mt, [Satisfactory]

SHEAR DESIGN DETERMINED FROM THE FOLLOWING EXPRESSION

V
fv=
jbd

39

(TMS 402 2.3.5.2.1)

V
F sd

0.32

in2 / ft

psi

<

'
F v = ( SF ) MIN ( f m , 50) =

51.64 psi

[Satisfactory]
<

<

'
F v = ( SF ) MIN (3 f m , 150) =

Av =
s

0.60

in2 / ft

154.92 psi

( No shear reinf. Reqd )

Technical References:
1. "Masonry Designers' Guide, Third Edition" (MDG-3), The Masonry Society, 2001.

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Design for Bending Post at Top of Wall, Based on TMS 402-08

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


MASONRY STRENGTH

fm'

REBAR YIELD STRESS

fy

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)


SERVICE BENDING LOAD
M
=
SERVICE SHEAR LOAD
V
=
WALL THICKNESS
T
=
ANCHORAGE REBARS
2
#
Fy

BASE PLATE YIELD STRESS

1.5

ksi

60

ksi

Yes
0.6
0.116
8
4

36

ft-kips
kips
in
@ middle of wall
ksi

BASE PLATE WIDTH


a
=
6
in
BASE PLATE LENGTH
b
=
10
in
(REQUIRED BASE PLATE THK. t = 3/8 in & MIN. REBAR SPLICE LENGTH Ls = 21 in)
[THE ANCHORAGE DESIGN IS ADEQUATE.]

ANALYSIS
DETERMINE BASE PLATE THICKNESS (AISC 13th, F6-1)

where

4 oM
=
4
b
Fy
3

in

3/8

(4/3) is seismic/wind factor, typical.

CHECK MASONRY BEARING CAPACITY (TMS 402 2.1.8)

fa=

2M
2
3

( 0.5a )

2T
b ( 0.5a )

7.20

kips

480

psi

<

4
or 1.0 0.25 f 'm =
3

500

psi

[SATISFACTORY]

12.80

kips

[SATISFACTORY]

CHECK REBAR CAPACITY (TMS 402 2.3.2.1)


T=

7.20

<

kips

(4/3 or 1.0) Fs As = (4/3) (24 ksi) As =

CHECK SHEAR CAPACITY (TMS 402 2.1.4.3.2)

'

'

V allow = MIN 1.25 A pv f m , 350 4 f m Ab , 2.5 A pt


where

Lbe =

3.56

Apt = Apv = Lbe =


2

'

f m , 0.36 f y Ab

1.46

kips

>

V
[SATISFACTORY]

in (rebar edge distance)


39.87

2
in , only one projected area used conservatively. (TMS 402 1.16.2 & 1.16.3)

__

DETERMINE LAP SPLICE LENGTH (TMS 402 2.1.9.7.1)


L d = e MAX[ 0.13 db2 fy / (K fm' 0.5 ) , 12 ] =

40 db

20.14

Page 223 of 533


524

in

PROJECT :
CLIENT :
JOB NO. :
DATE :
Fastener Anchorage in Combined Stresses Based on TMS 402-08 / IBC 09

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


MASONRY STRENGTH
fm '

1.5

ksi

60

ksi

0.42

kips / ft

kips / ft

0.85

kips / ft

FASTENER YIELD STRESS


fy
TENSION STRESS, ASD
ba

SHEAR STRESS, VERTICAL


bv,V

SHEAR STRESS, HORIZONTAL


bv,H
WALL THICKNESS
b

in

FASTENER DIAMETER

1/2

in

EFFECTIVE EMBEDMENT

Lb

in

[THE ANCHORAGE DESIGN IS ADEQUATE.]

EDGE DISTANCE TO WALL TOP Lbe

16

in

FASTENER SPACING

12

in, o.c.

Yes

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

ANALYSIS
CHECK MIN. EMBEDMENT (TMS 402 1.16.6)
Lb,min = MIN[ 4 , 2] = 2.00

in

Lb

<

[SATISFACTORY]

CHECK TENSION CAPACITY FOR A FASTENER (TMS 402 2.1.4.3.1.1)


Ba = MIN[ 1.25Apt(fm')0.5 , 0.6Abfy] =

3.80

>
Where

L = MIN[ Lb , Lbe] =

5.00

= COS-1(0.5S / L) =

k S ba [SATISFACTORY]
in, conservative value
0.00

Aseg = L [ - 0.5 SIN(2)] =

kips / fastener

0.00

rad
in2

Apt = L2 - 2Aseg =

78.54

in2 (TMS 402 1.16.2)

Ab = 2 / 4 =

0.20

in2

k=

3/4

CHECK SHEAR CAPACITY (TMS 402 2.1.4.3.2)


Bv = MIN[1.25Apv(fm')0.5 , 350(Abfm')1/4 , 2.5Apt(fm')0.5 , 0.36Abfy] =

Where

1.45

>

S bv,V

, Gravity only

>

k S bv

, Combined shear [SATISFACTORY]

-1

= COS (0.5S / Lbe) =

1.19

Aseg = Lbe2 [ - 0.5 SIN(2)] =


Apv = 0.5( Lbe2 - 2Aseg) =
bv = (bv,V + bv,H)0.5 =

[SATISFACTORY]

rad

2
303.72 in

98.41
1.312

in2 (TMS 402 1.16.3)


kips / ft

CHECK COMBINED SHEAR AND TENSION CAPACITY (TMS 402 2.1.4.3.3)


S ba / Ba + S bv / Bv =

kips / fastener

1.02

<

1.33

[SATISFACTORY]

PROJECT :
PAGE :
CLIENT :
DESIGN BY :
JOB NO. :
DATE :
REVIEW BY :
Fastener Anchorage in Tension & Perpendicular Shear Based on TMS 402-08 / IBC 09
INPUT DATA & DESIGN SUMMARY
MASONRY STRENGTH

fm'

1.5

ksi

FASTENER YIELD STRESS

fy

60

ksi

SERVICE TENSION LOAD

ba

0.9

kips / ft

SERVICE SHEAR LOAD

bv

0.4

kips / ft

WALL THICKNESS
FASTENER DIAMETER

=
=

8
3/4

in
in

EFFECTIVE EMBEDMENT

Lb

in

FASTENER SPACING

in

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

Yes

[THE ANCHORAGE DESIGN IS ADEQUATE.]

ANALYSIS
CHECK MIN. EMBEDMENT (TMS 402 1.16.6)
Lb,min = MIN[ 4 , 2] =

2.00

in

<

Lb

[SATISFACTORY]

CHECK TENSION CAPACITY (TMS 402 2.1.4.3.1.1)


Ba = MIN[ 1.25Apt(fm')

0.5

, 0.6Abfy] =

1.80

k S ba [SATISFACTORY]

>
Where

Lbe =

3.44

in

L = MIN[ Lb , Lbe] =

3.44

in, conservative value

-1

= COS (0.5S / L) =

0.00

Aseg = L [ - 0.5 SIN(2)] =


2

Apt = L - 2 Aseg =
2
Ab = / 4 =

k=

kips / fasteners

0.00

rad
2
in

37.18

in (TMS 402 1.16.2)

0.44

in

3/4

CHECK SHEAR CAPACITY (TMS 402 2.1.4.2.3)


Bv = MIN[1.25Apv(fm')

0.5

, 350(Abfm')1/4 , 2.5Apt(fm')0.5 , 0.36Abfy] =

1.78

>
Where

Apv = Apt =

37.18

k S bv

0.48

[SATISFACTORY]

in , since L = MIN[ Lb , Lbe] used above, (TMS 402 1.16.3)

CHECK COMBINED SHEAR AND TENSION CAPACITY (TMS 402 2.1.4.3.3)


S ba / Ba + S bv / Bv =

kips / fasteners

<

1.33

[SATISFACTORY]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Fastener Anchorage in Tension & Parallel Shear Based on TMS 402-08 / IBC 09

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


MASONRY STRENGTH

fm'

1.5

ksi

FASTENER YIELD STRESS

fy

60

ksi

UPLIFT STRESS, ASD

ba

0.5

kips / ft

SHEAR STRESS IN WALL DIR

bv

0.2

kips / ft

WALL THICKNESS
FASTENER DIAMETER

=
=

8
1/2

in
in

EFFECTIVE EMBEDMENT

Lb

in

FASTENER SPACING

16

in, o.c.

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

Yes

[THE ANCHORAGE DESIGN IS ADEQUATE.]

ANALYSIS
CHECK MIN. EMBEDMENT (TMS 402 1.16.6)
Lb,min = MIN[ 4 , 2] =

2.00

in

Lb

<

[SATISFACTORY]

CHECK TENSION CAPACITY (TMS 402 2.1.4.3.1.1)


Ba = MIN[ 1.25Apt(fm')

0.5

, 0.6Abfy] =

1.93

>
Where

Lbe =

3.57

kips / fastener

k S ba [SATISFACTORY]

in

L = MIN[ Lb , Lbe] =

3.57

in, conservative value

-1

0.00

rad

= COS (0.5S / L) =

Aseg = L2 [ - 0.5 SIN(2)] =


2

Apt = L - 2Aseg =
2
Ab = / 4 =

k=

0.00

in

39.93

in (TMS 402 1.16.2)

0.20

in

3/4

CHECK SHEAR CAPACITY (TMS 402 2.1.4.2.3)


Bv = MIN[1.25Apv(fm')

0.5

, 350(Abfm')1/4 , 2.5Apt(fm')0.5 , 0.36Abfy] =

1.45

>
Where

Apv = Apt =

39.93

k S bv

0.53

[SATISFACTORY]

in , since L = MIN[ Lb , Lbe] used above, (TMS 402 1.16.3)

CHECK COMBINED SHEAR AND TENSION CAPACITY (TMS 402 2.1.4.3.3)


S ba / Ba + S bv / Bv =

kips / fastener

<

1.33

[SATISFACTORY]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Double Fastener Anchorage in Tension & Shear Based on TMS 402-08 / IBC 09

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


MASONRY STRENGTH

fm'

1.5

ksi

FASTENER YIELD STRESS

fy

60

ksi

SERVICE TENSION LOAD

ba

0.91

kips / 2 fasteners

SERVICE SHEAR LOAD

bv

0.728

kips / 2 fasteners

WALL THICKNESS
FASTENER DIAMETER

=
=

8
3/4

in
in

EFFECTIVE EMBEDMENT

Lb

in

FASTENER SPACING

in

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

Yes

[THE ANCHORAGE DESIGN IS ADEQUATE.]

ANALYSIS
CHECK MIN. EMBEDMENT (TMS 402 1.16.6)
Lb,min = MIN[ 4 , 2] =

2.00

in

Lb

<

[SATISFACTORY]

CHECK TENSION CAPACITY (TMS 402 2.1.4.3.1.1)


Ba = 2 MIN[ 1.25Apt(fm')

Where

Lbe =

0.5

, 0.6Abfy] =

3.50

kips / 2 fasteners

>

k ba

[SATISFACTORY]

3.44

in

L = MIN[ Lb , Lbe] =

3.44

in, conservative value

-1

0.51

rad

= COS (0.5S / L) =

Aseg = L2 [ - 0.5 SIN(2)] =


2

Apt = L - Aseg =
2
Ab = / 4 =

k=

1.00

in

36.18

in (TMS 402 1.16.2)

0.44

in

3/4

CHECK SHEAR CAPACITY (TMS 402 2.1.4.2.3)


Bv = MIN[1.25Apv(fm')

0.5

, 350(Abfm')1/4 , 2.5Apt(fm')0.5 , 0.36Abfy] =

>
Where

Apv = Apt =

36.18

0.47

<

kips / 2 fasteners

k bv

[SATISFACTORY]

in , since L = MIN[ Lb , Lbe] used above, (TMS 402 1.16.3)

CHECK COMBINED SHEAR AND TENSION CAPACITY (TMS 402 2.1.4.3.3)


ba / Ba + bv / Bv =

3.50

1.33

[SATISFACTORY]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Masonry Wall Design at Horizontal Bending, Based on TMS 402-08

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


SPECIAL INSPECTION ( 0=NO, 1=YES )
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
=
MASONRY STRENGTH
fm'
REBAR YIELD STRESS
fy
=

0
1
1.5
60
Yes
45
8
24
10
24
24
4

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

SERVICE LATERAL LOAD


THICKNESS OF WALL
WALL HEIGHT
PILASTER SPACING
PILASTER SIZE

w
t
h
L
c1
c2
1

WALL HORIZ. REINF. (Asv)

=
=
=
=
=
=
#

No
CMU
ksi
ksi
psf
in
ft
ft
in
in
@

[THE WALL DESIGN IS ADEQUATE.]


48

in o.c. (at middle)

ANALYSIS
DESIGN CRITERIA
1. Pilaster spacing less than one half the unsupported vertical span of out-of-plane wall. (MDG-3,page 11-8)
L=
10
ft
<
0.5 h =
12 ft
[Satisfactory]
2. Pilaster stiffness greater than that the tributary area of wall. (TMS 402 1.7.4)
120 in, (TMS 402, 1.7.6.1 & 1.9.4.2.3)
beff = c1 + 12 t =
y=
7.4
in
E Ipilaster =
52809 E
,(TMS 402, 1.9.2)
4096 E
,(TMS 402, 1.9.2)
E Iwall =
>

E Ipilaster

E Iwall

[Satisfactory]

CHECK WALL HORIZONTAL BENDING CAPACITY


d
=
3.82 in, effective depth
=
12 in
bw
=
7.63 in, effective thickness
te
2
As
=
0.05 in / ft

k = 2 n + ( n ) n =
2

)=

'
m

M allowable = MIN

1
kd
b wkd F b d
2
3

ksi
ksi
21.48 , modular ratio
0.0011 , reinforcement ratio
0.667 , allowable stress factor
2000 or 24000 = 32000 psi
1350

29000

F S = (1.33 or 1.0) (

0.1944

F b = ( SF ) 0.33 f

=
=
=
=
=

Em
Es
n

SF

330 psi

w ( L c1 )
=
8

, As F s d

kd
3

437 ft-lbs/ft, (MDG-3, page 11-3)

max

360 ft-lbs/ft

<

M allowable

[Satisfactory]

CHECK SHEAR CAPACITY (TMS 402 2.3.5.2.2)


F v = ( SF ) MIN

'
m

, 50 =

26

psi

>

f v = 0.5 (L - c 1 ) w / (b w d) =

__

Technical References:
1. "Masonry Designers' Guide, Third Edition" (MDG-3), The Masonry Society, 2001.

Page 228 of 533


524

4
[Satisfactory]

psi

! "#

$%

&

$"& '% ! "#$" () "'* +() , " - .

!" #$% !&'

)*

/( # '

(,

.
/

( 0 (*
12 3

435.
6

8
,(
8

!"
!& '

.
/
95.

95.
$ (!:3 ;:<"0=:4> )

=
5

-, (

$ *

4/=2:3

12 3

$=*5 *(

435.
6

--

C5 * -

.
/

.
/*

8
,(

.
/*&45:/3" =:? 3
.
/*4 @
4= /> 435 =A 435;4=.
/B

.
/
.
/

(-

.
/
,

12 3

435.
6

8
,(
8

!"
C5

95.

C5

12 3

(E C.
B

9.
;5
435.
6

8
,(
--

C5

95.

.
/*

( *
5

.
/

,(

C5 * -

.
/
.
/
95.
*

( *

.
/
,

12 3

435.
6

8
,(

!"
C5

8
-

.
/
95.
95.
*

- 0D

( 0 (*

!"

#$

"# $%& "'(

"% &#$ '

*+ !,+-!

56 7

8790
:

!)

2 !3

+#

" ,

/
+!

()*) &

0
1

/ !4 2+

"#

<!)

0
1

<

=90

"' (

=90
% )">7 ?>@#4A>8B *

A
9

) !) 0
1+'89>17# A>C 7
- -) 0
1+8 D
8A 1B 879AE 879?8A0
1F

&

81A6>7

56 7

%A+9+)

% +!
8790
:

*
;

0
1+

"# $%& "'(

0
1

3 G0
F

*+ ! ,
/
) 4 )+!

8790
:

"' (

0
1
-

<
-)

"#

+"7>'

)-

56 7

0
1+

0
1

) +

0
1

<
-)

8790
:

!)

56 7

<
)

0
1
=90
=90
% )">7 ?>@#4A>8B *

A
9
&

//
-!)

0
1+'89>17# A>C 7
0
1+ 879AE 879?8A0
1F

%A+9+)

//

0
1

) 4 )+!

PROJECT :
CLIENT :
JOB NO. :

DATE :

Development & Splice of Reinforcement in Masonry Based on TMS 402-11 / ACI 530-11 & 2012 IBC
TENSION & COMPRESSION DEVELOPMENT
Ld = e MAX[ 0.13 db2 fy / (K fm' 0.5 ) , 12 ]

57 db

43

in

TMS 402-11, 2.1.7.3


where

Bar size
db

6
0.75

in

fy

60

ksi

fm'

1.5

ksi

1.0

(1.5 for epoxy-coated)

c
s
K

=
=
=
=

1.3
3.44 in, masonry cover
7.25 in, adjacent bars clear spacing
MIN( c , s , 5db ) =
3.44 in

ANCHORAGE OF FLEXURAL REINFORCEMENT


Lanchor = MAX ( d , 12 db ) =
where

53 db

Bar size
db

6
0.75

in

40

in

40

in, TMS 402-11, 2.1.7.4.1.3

TENSION HOOKS
Le = 13 db =

10

T = As F s =
where

in, TMS 402, 2.1.7.5

3.30

kips

Bar size
db

6
0.75

As

0.44

in
in2

Fs

7.5

ksi, TMS 402, C 2.1.7.5

TENSION OR COMPRESSION SPLICE


Ld = e MAX[ 0.13 db2 fy / (K fm' 0.5 ) , 12, 36 db ]

where

Asc

Bar size
db

fy

57 db
0

43

in

1
6
0.75

in

60

ksi

fm'

1.5

ksi

1.0

(1.5 for epoxy-coated)

c
s
K

=
=
=
=

, TMS 402-11, 2.1.7.7.2

1.3
3.44 in, masonry cover
7.25 in, bars clear spacing
MIN( c , s , 5db ) =
3.44 in

( 2012 IBC 2107.2 : Ld = 1.5 MAX( 0.002 db fs , 12 , 40 db )

where

TMS 402-11, 2.1.7.7.1


in2

fs

24

ksi )

54

in

PAGE :
DESIGN BY :
REVIEW BY :

PROJECT :
CLIENT :
JOB NO. :

24.6658
24.6658

DATE :

PAGE :
DESIGN BY :
REVIEW BY :

Tables for Development & Splice of Reinforcement Based on IBC 06 / CBC 07 / ACI 530

TENSION & COMPRESSION DEVELOPMENT


Table 1: Ld Values (inch)
Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

1000
25
25
31
52
73
112
145
188
237
357
702

1500
24
20
25
43

118
153
193
292
573

fm' (psi)
2000
2500
24
24
17
16
22
20
37
33
46
71
102
92
133
119
167
150
253
226
496
444

3000
24
14
18
30
42
64
84
108
137
206
405

3500
24
13
16
28
39
60
77
100
126
191
375

ANCHORAGE OF FLEXURAL REINFORCEMENT


Table 1: Lanchor Values (inch)
Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

1000
40
40
40
40
40
40
40
40
40
40
40

1500
40
40
40
40
40
40

40
40
40

fm' (psi)
2000
2500
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40

3000
40
40
40
40
40
40
40
40
40
40
40

3500
40
40
40
40
40
40
40
40
40
40
40

TENSION SPLICE WITH 80% STRESS OR LESS,


OR COMPRESSION SPLICE

TENSION SPLICE WITH MORE THAN 80% STRESS


Table 1: Ls Values (inch)
Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

1000
25
36
45
54
73
112
145
188
237
357
702

1500
24
36
45
54
63
91
118
153
193
292
573

fm' (psi)
2000
2500
24
24
36
36
45
45
54
54
63
79
102
92
133
119
167
150
253
226
496
444

Table 1: Ls Values (inch)

3000
24
36
45
54

84
108
137
206
405

3500
24
36
45
54
63
72
81
100
126
191
375

Bar
Size
#3
#4
#5
#6
#7
#8
#9
# 10
# 11
# 14
# 18

1000
25
25
31
52
73
112
145
188
237
357
702

__
Page 232 of 533
524

1500
24
24
30
43

118
153
193
292
573

fm' (psi)
2000
2500
24
24
24
24
30
30
37
36
46
71
102
92
133
119
167
150
253
226
496
444

3000
24
24
30
36
42
64
84
108
137
206
405

3500
24
24
30
36
42
60
77
100
126
191
375

"# $

"#

G,

&

&$& '()&$& (*+&, -

"# 04/

'

"

)
&&

# *

'

#+"

*-#

../

*-#

0 0/

&
4

123

32'

& , /

"

#
2?

0 -/

0#

2?

"0

::;
$/

00

> =

,2''21= $(' =$ @=' 5$3


*-# 0 0 <
=93>9('2;?$(: (@<>:!(2 1/

&21'934A0<# <B .#C 39


#* " .
?
8#
(<
.#4-#8 +"

<

0 -/

5 A' <
93

4 '- 5 A ' <

(9 1 ,2'

8
=$3$

*-# < $1 00 /

25

=$3$

# "

5;
$ ?$2

40

(1$ D2;
;1321 $:/

0#-# /

*4*

'- 5 A ' <


E 2'

=$3$

?D

4
#""
#. +

(<

'$

( A'

"

(<

###*
&?

""# 5

:
(
&

4
04###

21'93!F

PROJECT :
CLIENT :
JOB NO. :
DATE :
Design of Masonry Bearing Wall with Opening Based on TMS 402-08

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


TYPE OF MASONRY ( 1=CMU, 2=BRICK )
1
CMU
MASONRY STRENGTH
fm'
=
1.5
ksi
=
60
ksi
REBAR YIELD STRESS
fy
GRAVITY LOAD, ASD
P
=
640
lbs / ft
ECCENTRICITY
e
=
6
in
LATERAL LOAD, ASD
w
=
26.7 psf
OPENING WIDTH
L
=
4.33 ft
LINTEL HEIGHT
Lintel
=
4
ft
THICKNESS OF WALL
t
=
8
in
=
4
ft
PARAPET HEIGHT
hp
WALL HEIGHT
h
=
16
ft
WALL VERT. REINF.
1
layer
#
5
VERT. JAMB BARS
2
#
5
LINTEL VERT. REINF
1
leg
#
4
LINTEL BOT/TOP BARS
2
#
6
DIAPHRAGM SUPPORT LINTEL LATERAL LOAD (Yes, No) ?

16

in o.c. (at middle)

in o.c. (at middle)

No

[THE WALL DESIGN IS ADEQUATE.]

ANALYSIS
CHECK JAMB CAPACITY UNDER LATERAL & AXIAL LOADS (TMS 402-08 2.3.3)
6t=
beff =
48
in, (TMS 402-08 1.9.4.2.3)
PJamb =

P (beff + 0.5 L) / beff =

986

lbs / ft, at ledger

wJamb =

w (beff + 0.5 L) / beff =

41

psf

S=

8.25

ft

Mmax =

1470

ft-lbs / ft

PM =
As =

2556
lbs / ft, at max M section
2
(wall + Jamb) = 0.31 in / ft

Mallow =

1711

(Assuming that opening has same wall loads.)

ft-lbs / ft

Mmax

>

[Satisfactory]

(See MasonryBearingWall-IBC.xls on www.engineering-international.com for the Mallow at PM calculation,


or see Masonry Designers' Guide, Third Edition, The Masonry Society, 2001. Page 12-25.)
Vmax =

MAX (V1 , V2) =

339 lbs / ft

Vallow =

<

4728

lbs / ft

[Satisfactory]

CHECK LINTEL CAPACITY UNDER GRAVITY & LATERAL LOADS (TMS 402-08 2.3)
psi =
fb = Gravity + Lateral =
11 psi +
484
495
psi
<

Fb =

fs = Gravity + Lateral =
<
where

Fs =

495 psi

[Satisfactory]

629 psi +

308

24000 psi

MGav =

MLat =
As,Lat =
fv = Gravity + Lateral = (
<

Fv =

937

0.88

ft-lbs
in

0.002487 ,for gravity

k=

0.278

__

5.06
39

psi

[Satisfactory]

1940

As,Gav =

psi =

135

ft-lbs

0.88

in2

k=

0.004

5.08

psi

psi

0.43

)0.5 =

[Satisfactory]

Page 234 of 533


524

0.003053 ,for lateral

!.& #

.. . $

$ /% 0

!
#

$( % 101 23 1# 4 $

"
$%&

'

$*
B

()

()

+ '0!

'

,-.)
/*

'

( -/ 2)
3
- / ,4 5/ ,

6'

( %-* 7 5 8-/)
.

9!

$/:( 2; )
/ ;,5 8-/)
.

)
5
/

!<

!0+0

!0+0

<

<9
!<
9
#

>

'

#
#

!
B

38 ?

$/
)
5 ;4

'0

;53
* 2)
3
- / ,8,;C/ =

5!
0 + )

*/

)
5

000

5<
06 69 )

!6

+ '0!

%-E

)
5

()
()

60

"
)
5!

)
5

0'

0 +

! <9

5!
D69 )

6 0 )
5

00'

!'7=

'0 !
)
5!

<

< 7=

!! 0<

)
5!

+<

)
5!
1

<90 ( )

()

! "
1

1
0!

#
' 00

1
!6 ( )
"

" #$ $

()

&%

'$(

96

()

)
5<

!)"
1

#
+ !!D (

! "
1

1
<<6!+ (

"

1
' +< 2 )

4 ! 0'!

'< 6! 2 )

'

)
5! G$/

)
5! G$/

#$

$%

$,( -

#$% &

$$ $ '

' () *

!
#

'+ ) ,*, -.,& / '

"
$%&

'

$*

()
()

,
!

-.

-.

'

0
0 #

'

( 1 2 34 .4-5-$5)
6
74 .

$48( 5- )
4 -.3 974)
:

!
#

)
3
;

!,

,;
!,

<

;
#

!>

#
#

!
A

69 ?
-

$4

)
3 -2

3!
! /D )
3!
D>; )

*4

>

()

'
,

'

+ ' /!

%7E

#
& I!H!G3 H !38

)
3

C&JC IK! 8G3 H !38

&I

!D;
8

8(J/

>D

3!
>; )
'/ !

)
3!

0
( FG3 H !38

! ,;

"

! /; )
3

()

!>

, D,

///

)
3

/'

3H 8 H3 H3 & 2 <

! !'

)
3

4-476

> / )
3

&
C&

3,
/> >; )

7
//'

-36
* 5)
6
7 4 .9.-B4 C

'/

+,

'<C
,<C

! '/

)
3!

! !

)
3!

!! /'/ (
#

"
)
CJ

0
!;

)
CJ

5)

J*

/> 5)

4 3 )
6 E)4
0

/!+/' (

69-: .3

"

0
/!

!++;
0

()
#

) ,$

!
"

"

#
$ %%

"

&& '

&

$,%$
&& '

#
$) * !

+ ,$

,$

%,

!, ./

!, ./

+ 0 !12 +/+3+ + 4
$5 1

36 + !
7 +3 (8!+9 0!
3

!! 5

(:% 9 0+ 1

36

!
+ 69,

-, * !

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Flush Wall Pilaster Design Based on TMS 402-08 & IBC 09


INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
MASONRY STRENGTH
fm'
=
=
REBAR YIELD STRESS
fy

1
1
1.5
60
Yes
3
50
9.5
8.2

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

SEISMIC DESIGN CATEGORY (5=Gravity)


SERVICE AXIAL LOAD
P
=
SERVICE SHEAR LOAD
V
=
SERVICE MOMENT
M
=
SECTION DIMENSIONS (in)
input
8

te =

7.63

D=

24

d=

23.63

L=
B=

48
24

Le =

48.00

b=

23.63

R=

80

Re =

48.00

=
2
4

15
#
@

WALL GROUTED ? (Yes, No)

D
k, at pilaster center
k, (may be negative)
ft-k, (posite or negative)

effective

t=

WALL PILASTER HEIGHT


h
VERTICAL REINF. (EACH SIDE)
legs #
HORIZ. TIES
2

Yes
CMU
ksi
ksi

ft
8
8

in o.c.

No , (only pilaster grouted)

DISTANCE PILASTER REINF.


(TMS 402, 1.15.3.5)

a=

19.13

in

[THE WALL PILASTER DESIGN IS ADEQUATE.]

ANALYSIS
TOTAL REINFORCEMENT AREA

As

3.16

in2

TOTAL EFFECTIVE AREA

An

798

in

NEUTRAL AXIS FROM WALL FACE

yt

in

NET MOMENT OF INERTIA

In

MASONRY ELASTICITY MODULUS

Em

1350 ksi

STEEL ELASTICITY MODULUS

Es

29000 ksi

RADIUS OF GYRATION

39198 in
7.01

MODULAR RATIO

21.48

PILASTER REINF. RATIO

0.006

ALLOWABLE STRESS FACTOR

SF

1.333

MAX. TIES SPACING (TMS 1.17.4)

Smax

in

in
TRANSFORMED WALL PILASTER AREA

At = An + bd ( 2n 1) =

2
931 in

CHECK VERTICAL REINFORCEMENT LIMITATION OF PILASTER (TMS 402 1.14.1.2)


2
2
in
As =
> 0.0025 bd =
1.40
[Satisfactory]
3.16 in
< 0.04 bd =
ALLOWABLE STRESS DUE TO AXIAL LOAD ONLY

h
140r

'
F a = ( SF ) 0.25 f m 1.0

22.34

0.660

M T = M + ( 0.1)

F S = (1.33 or 1.0 )( 20 or 24 ) =

ksi

0.060

I t = I n + ( 2n 1) As

13.1 ft-kips

32.0

a
2

51330 in

f m = f a+ f b =

0.089 ksi
< Fb, [Satisfactory]

AXIAL LOAD AT BASE OF THE WALL PILASTER

P t = P + ( full col. weight ) =

ksi
3.6
< Fs, [Satisfactory]

61.227 k

ALLOWABLE AXIAL LOAD FOR AXIAL COMPRESSION ONLY

( ( SF ) 0.25 f

'
m

An + 0.65 F S A S

1.0

h
140r

449.26 k
[for h/r < 99]

__

> Pt, [Satisfactory]

SHEAR DESIGN DETERMINED FROM THE FOLLOWING EXPRESSION

V
fv=
bd

(TMS 402 2.3.5.2.1)

V
F sd

0.15

17

in / ft

psi

ksi

MAX.STRESS COMBINED AXIAL & FLEXURE

MAX. REINF. STRESS COMBINED AXIAL & FLEXURE

Pa =

ksi

TRANSFORMED MOMENT OF INERTIA

0.029 ksi
< fa, [Satisfactory, the section is uncracked]

a
f S = 2n f a + f b =
d

At

< Fa, [Satisfactory]


ALLOWABLE REINF. STRESS DUE TO FLEXURE

STRESS IN THE EXTREME FIBER DUE TO MT

M Ty =
fb=
It

P + ( half wall weight )

fa=

0.483 ksi

TOTAL MOMENT ACTING AT MIDHEIGHT

Pd
=
2

[Satisfactory]
AXIAL STRESS AT MIDHEIGHT OF THE PILASTER

[for h/r < 99]


ALLOWABLE STRESS DUE TO FLEXURE
'
F b = ( SF ) 0.33 f m =

in2

<

F v = ( SF ) MIN ( f m , 50) =
'

51.64 psi

[Satisfactory]

<

<

F v = ( SF ) MIN (3 f m , 150) =
'

Av =
s

0.60

Page 238 of 533


524

in / ft

154.92 psi

( No shear reinf. Reqd )

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Flush Wall Pilaster Design Based on TMS 402-08 & IBC 09


INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES )
1
Yes
TYPE OF MASONRY ( 1=CMU, 2=BRICK )
1
CMU
=
1.5
ksi
MASONRY STRENGTH
fm'
=
60
ksi
REBAR YIELD STRESS
fy
SEISMIC DESIGN CATEGORY
4
E or F
( 1 = B, 2 = C, 3 = D, 4 = E or F, 0 = WIND, 5 = GRAVITY)
SERVICE AXIAL LOAD
MAX SHEAR LOAD
MOMENT AT MIDHEIGHT

P
V
M

=
=
=

11.5
20
106

SECTION DIMENSIONS (in)


input

effective

t=

te =

7.63

D=

24

c=

23.63

L=

48

Le =

48.00

B=

24

b=

23.63

R=

80

Re =

48.00

=
3
4

29
#
@

WALL PILASTER HEIGHT


h
VERTICAL REINF. (EACH SIDE)
HORIZ. TIES
2
legs #
WALL GROUTED ? (Yes, No)

k, @ center top of pilaster


k
ft-k, (posite or negative)

ft
8
8

in o.c.

DISTANCE PILASTER REINF.


a = 19.13
(TMS 402, 1.15.3.5)
[THE WALL PILASTER DESIGN IS ADEQUATE.]

in

No , (only pilaster grouted)

ANALYSIS
= ' =
d' = 2.25 , d =

As
An

=
=

2.37
798

in2
2
in

PILASTER REINF. RATIO


DISTANCE

NEUTRAL AXIS FROM WALL FACE

yt

in

ALLOWABLE STRESS FACTOR

SF

1.333

NET EFFECTIVE MOMENT OF INERTIA

In

MAX. TIES SPACING (ACI 1.1.4.6)

Smax

=
=
=
=

REINFORCEMENT AREA AT ONE SIDE

TOTAL EFFECTIVE AREA

RADIUS OF GYRATION
MASONRY ELASTICITY MODULUS
STEEL ELASTICITY MODULUS
MODULAR RATIO

39198 in

7.01 in
1350 ksi
Em
29000 ksi
Es
n
21.48
2
At = An+(-+n+n' ) c b = 908 in

TRANSFORMED AREA

CHECK VERTICAL REINFORCEMENT LIMITATION (TMS 402 1.14.1.2)


2
As,total =
4.74 in
> 0.005Ae = 0.005bd =
0.04Ae = 0.04bd =

<
AXIAL LOAD AT MIDDLE OF THE PILASTER

psi

<

LEVER-ARM FACTOR

MMid / (In / y) =

'
P a = 0.25 f m An + 0.65 F S A st 1.0

309

h
140r

ALLOWABLE REINF. STRESS DUE TO FLEXURE

F S = (1.33wind & seismic only ) ( 20 or 24 ) =

in

20.21

in

FS =
EmSE m =
fb=e

0.0011

=
=

j = 1-k/3

0.278
0.907

[Satisfactory]
[Satisfactory]

M Mid = M + ( 0.1)

107.1 ft-kips

AXIAL LOAD AT BASE OF THE PILASTER


psi

P t = P + ( full wall weight ) =

26.681 k

326.35 k
[for h/r < 99]

> Pt, [Satisfactory]

P Mid
'
F b = SF
Pa

__
32.0

Pd
=
2

ALLOWABLE STRESS DUE TO FLEXURE


ksi

THE CORRESPONDING STRAIN IN THE TENSILE BARS IS

eS =

2.53

(tensile exist)
ALLOWABLE AXIAL LOAD FOR AXIAL COMPRESSION ONLY

in

NEUTRAL AXIS DEPTH FACTOR


k = {[n+(2n-1)' ]2+2[n+(2n-1)(d'/d)]}2 - [n+(2n-1)' ]

22.353 k

CHECK IF THERE IS TENSILE STRESS IN CROSS SECTION


28

in

TOTAL MOMENT ACTING AT MIDHEIGHT

P Mid = P + ( half col. weight ) =


PMid / A =

0.005
21.38

( 0.33 f ) =
'
m

0.626

ksi

THE STRAIN IN THE EXTREME COMPRESSION FIBER IS

e m = MIN

Page 239 of 533


524

'
kd
Fb
es ,
d kd
Em

0.0004253
(steel governs)

(cont'd)
MOMENT DUE TO THE MASONRY

STRESS IN THE EXTREME FIBER DUE TO MT

f b = em E m =

0.574

ksi

Mm=

< Fb', [Satisfactory]

STRAIN IN THE COMPRESSION BARS


'
eS =

kd d
em =
kd

M = f AS (d d ) =
'
S

'

65.21

ft-kips

STRESS IN THE COMPRESSION BARS

'

'
f S = 2 E S e 'S =

0.0002644

MOMENT DUE TO THE COMPRESSION BARS


'
S

kd
1
bkd f b (d ) =
2
3

57.94

15.334

ksi

ALLOWABLE BENDING MOMENT

M =M S + M m =
'

ft-kips

123.15 ft-kips
> Mt, [Satisfactory]

SHEAR DESIGN DETERMINED FROM THE FOLLOWING EXPRESSION

V
fv=
jbd

39

(TMS 402 2.3.5.2.1)

V
F sd

0.32

in2 / ft

psi

<

'
F v = ( SF ) MIN ( f m , 50) =

51.64 psi

[Satisfactory]
<

<

F v = ( SF ) MIN (3 f m , 150) =
'

Av =
s

0.60

in / ft

( No shear reinf. Reqd )

Technical References:
1. "Masonry Designers' Guide, Third Edition" (MDG-3), The Masonry Society, 2001.

__
Page 240 of 533
524

154.92 psi

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Beam to Wall Anchorage Design Based on TMS 402 / IBC 09

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


MASONRY STRENGTH
fm'

1.5

ksi

60

ksi

3.2

kips

FASTENER YIELD STRESS


fy

SERVICE VERTICAL LOAD


P

VERTICAL LOAD TO FACE DIMENSION


e

in

SERVICE HORIZONTAL TENSION LOAD


T

1.12

kips

WALL THICKNESS
b

in

FASTENER DIAMETER

3/4

in

EFFECTIVE EMBEDMENT

Lb

in

DISTANCE TO WALL TOP

in

[THE BEAM ANCHORAGE DESIGN IS ADEQUATE.]

Lbe

16

NO. ANCHORS (4,6,or 8)

SPACING

Sh

in, o.c.

VERTICAL SPACING

Sv

11

in, o.c.

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

MIN. FACE PLATE SIZE - 11 in x 14 in

Yes

ANALYSIS
ANCHOR LOCATION & FORCE
MAX TENSION STRESS, ASD

Anchor

X (in)

Y (in)

XCG2

YCG2

Na

Va

ba
=
1.2
MAX SHEAR STRESS, VERTICAL

kips / fastener

1
2

-4.00
4.00

-5.50
-5.50

16.00
16.00

30.25
30.25

1.2
1.2

0.8
0.8

bv
GOVERNING SPACING
S

kips / fastener

3
4

-4.00
4.00

5.50
5.50

16.00
16.00

30.25
30.25

-0.6
-0.6

0.8
0.8

0.8

in, o.c.

CHECK MIN. EMBEDMENT (TMS 402 1.16.6)


Lb,min = MIN[ 4 , 2] =

2.00

<

in

Lb

[SATISFACTORY]

CHECK TENSION CAPACITY FOR A FASTENER (TMS 402 2.1.4.3.1.1)


Ba = MIN[ 1.25Apt(fm')0.5 , 0.6Abfy] =

3.41

>
Where

L = MIN[ Lb , Lbe] =

5.00

k ba =

kips / fastener
0.86

kips / fastener

= COS-1(0.5Sh / L) =

0.64

rad

Aseg = L2 [ - 0.5 SIN(2)] =

4.09

in2

Apt = L2 - 2Aseg =

70.36

in2 (TMS 402 1.16.2)

Ab = 2 / 4 =

0.44

in2

k=

[SATISFACTORY]

in, conservative value

3/4

CHECK SHEAR CAPACITY (TMS 402 2.1.4.3.2)


Bv = MIN[1.25Apv(fm')0.5 , 350(Abfm')1/4 , 2.5Apt(fm')0.5 , 0.36Abfy] =

>
Where

= COS-1(0.5S / Lbe) =

bv =
1.32

0.80

kips / fastener

rad

Aseg = Lbe2 [ - 0.5 SIN(2)] =

2
275.47 in

Apv = 0.5( Lbe2 - 2Aseg) =

2
126.65 in (TMS 402 1.16.3)

CHECK COMBINED SHEAR AND TENSION CAPACITY (TMS 402 2.1.4.3.3)


ba / Ba + bv / Bv =

0.79

<

1.33

1.78

[SATISFACTORY]

kips / fastener
, Gravity only

[SATISFACTORY]

PROJECT :
CLIENT :
JOB NO. :

DATE :

Collector to Wall Connection Design Based on TMS 402-08 / IBC 09


INPUT DATA & DESIGN SUMMARY
fm'

MASONRY STRENGTH
DRAG BARS

BAR YIELD STRESS

fy

1.5

60

ksi
60

in, Long (A 706)

ksi

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

Yes

SERVICE COLLECTOR FORCE (ASCE 7-05, 12.10.2.1 & 12.4.3.2)


T
=
55
kips, ASD level
[THE COLLECTOR TO WALL DESIGN IS ADEQUATE.]

ANALYSIS
CHECK DRAG BAR LENGTH (TMS 402-08, 2.1.9.3)
Ld = e MAX[ 0.13 db2 fy / (K fm' 0.5 ) , 12 ]

68 db

59

in

<
where

db

0.875

1.0

c
s

=
=
=

60

in

[SATISFACTORY]

in
(1.5 for epoxy-coated)

1.3
3.3775 in, masonry cover
7.125 in, adjacent bars clear spacing
MIN( c , s , 5db ) =

3.3775 in

CHECK DRAG BAR STRENGTH (TMS 402-08, 2.3.2.1)


Tallow = Fs As =

57.60

>
where

kips
T

[SATISFACTORY]

Fs

32

ksi, (IBC/CBC 1605.3.2 & TMS 402, 2.3.2.1)

As

1.8

in2

__
Page 242 of 533
524

PAGE :
DESIGN BY :
REVIEW BY :

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Hybrid Masonry Wall Design Based on TMS 402-11


DESIGN CRITERIA
1.
Masonry wall is within steel frame. There are gaps between steel column/beam and the wall.
2.
All gravity loads are supported by steel beam and steel column.
3.
Lateral load, F from diaphragm to beam, is transferred to the masonry wall by shear connectors.
4.
Shear connector (fuse detail) can only have horizontal shear capacity, without vertical support.
INPUT DATA & DESIGN SUMMARY

THE WALL DESIGN IS ADEQUATE.


( 10 shear connectors at 22 in. o.c.)

THICKNESS OF WALL
REINFORCING OF WALL

tw =

8
2

Ash, Horizontal

16

in o.c.

Asv, Vertical

24

in o.c.

F=
v=

30
3

SERVICE LATERAL LOAD


SHEAR CONNECTOR CAPACITY

HEIGHT OF WALL

hw =

14

ft

LENGTH OF WALL

Lw =

20

ft

MASONRY STRENGTH

fm' =

ksi

REBAR YIELD STRESS

fy =

60

ksi

in
at each ends, with

in center to edge.

kips, ASD level


kips/connector, ASD level

ANALYSIS
CHECK SPACING OF SHEAR CONNECTORS
n=F/v=
10
, number of connectors
s = Lw / (n + 1) =

22

in, shear connector spacing

>

in

[Satisfactory]

CHECK FLEXURAL & AXIAL CAPACITY BY ALLOWABLE STRESS DESIGN (ASD)

d

1600
1400

d

1200
1000

P (k)

800
600
400
200
d

0
0

1000

2000

3000

4000

-200

P=

22

d

M (ft-k)
kips, wall self weight,

M=

312

ft-kips, at wall bottom.

f m  0.25

P
Av F sd ,
 0.5
An
A ns

[Satisfactory]

CHECK SHEAR CAPACITY (ASD), (TMS 2.3.6)

MAX SF 4  1.75 MIN 1 , M T


4
Vd

Fv

Fv, Maximum

103

psi

>

SF MIN 3

'

1.5 fv
=
25
psi
(factor 1.5 from TMS 402 1.18.3.2.6.1.2)

4
M T
, MAX 2 , 2  1 

3
Vd

'
m

M T
4  1.75MIN 1 , Vd
2

SF

f m  0.25
'

[Satisfactory]

144

psi
>
[Satisfactory]

1.5 fv

An

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Post-Tensioned Masonry Shear Wall Design Based on TMS 402-11 (SD Method)
DESIGN CRITERIA
1.
2.
3.

The Post-Tensioned Masonry Shear Wall can be as the Self-Centering Lateral Frame, which is good against to seismic/wind loads.
The PT walls use smooth steel rods as the post-tensioned rods, in lieu of soft tendons, so easy construction.
The PT walls can be the exterior walls with the energy savings of LEED Gold, because no grouted all cells were required.

INPUT DATA & DESIGN SUMMARY


REBAR YIELD STRESS

fy =

60

ksi

MASONRY (CMU) STRENGTH

fm' =

ksi

LENGTH OF SHEAR WALL


(within vertical control joints)
EQUIVALENT THICKNESS
EFFECTIVE HEIGHT OF WALL

L=

12

ft

t=
h=

7.25
16

in
ft

SD LEVEL SECTION LOADS


Pu =

280

Mu =

900

ft-kips

Vu =

193

kips

kips, (not including PT)

THE WALL DESIGN IS ADEQUATE.


VERTICAL REINFORCING
1
#
I
7/16
( fse =

5
in

@
32
PT (smooth rods) @

14.5513 ksi ,

0.24

in o.c.
16

in o.c., with effective

5000

lbs / rod

fy )

ANALYSIS
CHECK FLEXURAL & AXIAL CAPACITY
Hmu =
I=

2500

2000

0.0025

, (TMS 3.3.2.c)

d=

0.8
140

, (TMS 402 4.4.3.3)


in

Ho =

0.00178

cb =

77

in, (balance point between Tension


Controlled and Compression Controlled.)

280

kips

IPn =

1013

IPn (k)

1500

Pu =

1000

<
500

Mu =
<

900

ft-kips

IMn =

1946

0
-500

500

1000

1500

2000

2500

3000

3500

[Satisfactory]

-500

IMn (ft-k)
CHECK SHEAR CAPACITY
Vu =

193

kips

<
IVnm =
[Satisfactory]

216

kips, including PT, (TMS 402 3.3.4.1.2)

kips, (TMS 402 3.3.4.1.1)

ft-kips, at Pu level.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Masonry Shear Wall with Opening Design Using Finite Element Method
INPUT DATA & DESIGN SUMMARY
DIMENSIONS
L=
30
H=
20
thk =
7.63
OPENING
b=
5
h=
10
LOCATION

ft
ft
in
ft
ft

L1 =

10

ft

H1 =

ft

R = 4199 kips (Rigidity)


Def. = 0.09 in (Deflection)

ONE STORY ?
Yes
(Cantilever Wall with Fixed Base Only)
MASONRY ( 1=CMU, 2=BRICK )
JAMB BARS
LATERAL LOAD

2
F=

#
345

ANALYSIS
DETERMINE SHEAR WALL LATERAL RIGIDITY

Joint

Not Apply

R = 3612 kips
Def. = 0.11 in

The opening reduced the lateral load capacity by 14%.

`
CMU

fm' =

1.5

ksi

fy =
60
ksi
6
, four sides opening w/ embed 48 bar dia. min.
kips, SD level
Element
Joints
No.
1
1, 2, 6, 7
2
2, 3, 7, 8
3
3, 4, 8, 9
4
4, 5, 9, 10
5
6, 7, 11, 12
6
7, 8, 12, 13
7
8, 9, 13, 14
8
9, 10, 14, 15
9
11, 12, 16, 17
10
14, 15, 18, 19
11
16, 17, 20, 21
12
18, 19, 22, 23
13
20, 21, 24, 25
14
21, 22, 25, 26
15
22, 23, 26, 27
16
24, 25, 28, 29
17
25, 26, 29, 30
18
26, 27, 30, 31

Solid Wall with Fixed at Top & Base


Reaction (kips)
Deflection (in)
X
Y
X
Y

Solid Wall with Fixed at Base only


Reaction (kips)
Deflection (in)
X
Y
X
Y

937

-1738

0.00

577

0.39

1104

-100

0.00

804

0.08

435

-40

0.00

402

0.03

1466

56

0.00

1425

-0.02

1579

1890

0.00

990

-0.33

0.87

0.06

0.85

0.39

0.89

0.00

0.85

0.08

0.89

0.00

0.85

0.03

0.89

0.00

0.85

-0.02

10

0.88

-0.04

0.87

-0.33

11

0.75

0.11

0.71

0.37

12

0.76

0.01

0.70

0.08

13

0.80

-0.01

0.73

0.03

14

0.76

0.00

0.70

-0.02

15

0.76

-0.08

0.73

-0.31

16

0.49

0.14

0.45

0.29

17

0.50

0.02

0.42

0.06

18

0.50

0.00

0.42

-0.01

19

0.51

-0.10

0.47

-0.25

20

0.24

0.10

0.22

0.17

21

0.23

0.01

0.18

0.04

22

0.24

0.00

0.18

0.00

23

0.25

-0.08

0.22

-0.14

24

0.12

0.06

0.11

0.09

25

0.11

0.01

0.08

0.02

26

0.11

0.00

0.08

0.00

27

0.13

-0.05

0.11

-0.08

28

-1096

-1727

0.00

0.00

-1071

-2449

0.00

0.00

29

-1147

-249

0.00

0.00

-689

-545

0.00

0.00

30

-1808

27

0.00

0.00

-1249

26

0.00

0.00

31

-1470

1882

0.00

0.00

-1191

2968

0.00

0.00

R=

-5520

kips

R=

-4199

kips

Dimension (ft)
X
Y
10.0
2.5
2.5
2.5
2.5
2.5
15.0
2.5
10.0
2.5
2.5
2.5
2.5
2.5
15.0
2.5
10.0
5.0
15.0
5.0
10.0
5.0
15.0
5.0
10.0
2.5
5.0
2.5
15.0
2.5
10.0
2.5
5.0
2.5
15.0
2.5

Thick.
(in)
7.63
7.63
7.63
7.63
7.63
7.63
7.63
7.63
7.63
7.63
7.63
7.63
7.63
7.63
7.63
7.63
7.63
7.63

(cont'd)

Joint

Opening Wall with Fixed at Top & Base


Reaction (kips)
Deflection (in)
X
Y
X
Y

Opening Wall with Fixed at Base only


Reaction (kips)
Deflection (in)
X
Y
X
Y

633

-1534

0.00

375

0.33

992

675

0.00

659

0.02

461

-30

0.00

567

0.03

1168

-792

0.00

1160

0.04

1434

1801

0.00

851

-0.30

0.90

0.06

0.87

0.33

0.91

-0.02

0.88

0.01

0.90

0.00

0.88

0.03

0.90

0.02

0.87

0.04

10

0.89

-0.04

0.87

-0.30

11

0.78

0.10

0.74

0.32

12

0.82

-0.05

0.76

0.00

13

0.84

-0.01

0.79

0.02

14

0.79

0.04

0.74

0.05

15

0.77

-0.07

0.75

-0.29

16

0.48

0.14

0.44

0.27

17

0.51

-0.07

0.44

-0.03

18

0.48

0.06

0.42

0.07

19

0.51

-0.11

0.47

-0.24

20

0.21

0.10

0.19

0.15

21

0.19

-0.03

0.14

-0.02

22

0.19

0.04

0.15

0.04

23

0.23

-0.08

0.20

-0.14

24

0.10

0.06

0.09

0.08

25

0.09

-0.02

0.07

-0.01

26

0.09

0.02

0.07

0.02

27

0.11

-0.04

0.10

-0.07

28

-929

-1567

0.00

0.00

-900

-2163

0.00

0.00

29

-842

608

0.00

0.00

-469

347

0.00

0.00

30

-1684

-933

0.00

0.00

-1267

-952

0.00

0.00

31

-1232

1771

0.00

0.00

-976

2769

0.00

0.00

R=

-4688

kips

R=

CHECK MASONRY SHEAR WALL OPENING


E=
1350
ksi
Min (L1 , L - L1 - b , H1) =
I f y Ag =
2

48
kips
#
6
(Jamb Bars)

X=
60

0.25
in

>
>

-3612

kips

(Poisson's ratio)
>

Max Corner Force =


2
#

Max (3 thk , 8 in) =


32
5

kips
in

23

in

[Satisfactory]
[Satisfactory]

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wood Joist Design Based on NDS 05 / NDS 01, ICC PFC-4354 & PFC-5803
INPUT DATA & DESIGN SUMMARY
L =
JOIST SPAN
35
DL =
DEAD LOAD
22
LL =
16
LIVE LOAD / SNOW
S =
24
JOIST SPACING
CD =
DURATION FACTOR
1.25

ft
psf, (w/o self Wt)
psf
in o.c.
(NDS Tab. 2.3.2)

REPETITIVE FACTOR

(NDS 4.3.9. For DSA, 1.0)

Cr =

1.15

AVAILABLE MINIMUM Douglas Fir-Larch SIZES

DEFLECTION LIMIT OF LIVE LOAD


DEFLECTION LIMIT OF LONG-TERM LOAD
DEFLECTION LIMIT OF TOTAL LOAD

AVAILABLE MINIMUM TJI SIZES


30" TJI/L65
28" TJI/L90
AVAILABLE MINIMUM SSI SIZES
28" SSI 42MX

LL = L / 360
1.5(DL+0.33LL) = L / 480
(DL+LL) = L / 240

26" TJI/H90
26" SSI 43LX

( L / 360 , 1.2 in )
( L / 480 , 0.9 in )
( L / 240 , 1.8 in )

ANALYSIS
JOIST PROPERTIES & ALLOWABLE MOMENT & SHEAR
2x No. 2, Douglas Fir-Larch ( ASD Supplements, Tab. 5.4a)
EI x 106
Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)
2
(in -lbs)
(CF included)
4
6
8
10
12

1.00
2.00
2.00
3.00
4.00

344
738
1183
1767
2375

630
990
1310
1670
2030

9
33
76
158
285

1.00

574

2.00

8
10
12

2.00
3.00
4.00

630

10

1225

990

40

1975
2942
3958

1310
1670
2030

91
188
338

V (lbs)

EI x 10
(in2-lbs)
450
666
913
1205
1545
1934
2374
2868
3417
4025

TJI/L65 ( from Trusjoist # 1062, page 5)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
11 7/8
14
16
18
20
22
24
26
28
30

3.30
3.60
3.90
4.20
4.40
4.70
5.00
5.30
5.50
5.80

6750
8030
9210
10380
11540
12690
13830
14960
16085
17205

TJI/L90 ( from Trusjoist # 1062, page 5)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
11 7/8
14
16
18
20
22
24
26
28
30

4.20
4.50
4.70
5.00
5.30
5.60
5.80
6.10
6.40
6.60

9605
11430
13115
14785
16435
18075
19700
21315
22915
24510

TJI/H90 ( from Trusjoist # 1062, page 5)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
11 7/8
14
16
18
20
22
24
26
28
30

4.60
4.90
5.20
5.40
5.70
6.00
6.30
6.50
6.80
7.10

10960
13090
15065
17010
18945
20855
22755
24645
26520
28380

1925
2125
2330
2535
2740
2935
3060
2900
2900
2900

V (lbs)
1925
2125
2330
2535
2740
2935
3060
2900
2900
2900

V (lbs)
1925
2125
2330
2535
2740
2935
3060
2900
2900
2900

(CF included)

4
6
8
10
12

2x Structural, Douglas Fir-Larch (ASD Supplements, Tab. 5.4a)


6
EI x 10
Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)
(in2-lbs)
(CF included)
4

2x No. 1, Douglas Fir-Larch (from WoodBeam.xls)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)

EI x 10
2
(in -lbs)
621
913
1246
1635
2085
2597
3172
3814
4525
5306

EI x 10
2
(in -lbs)
687
1015
1389
1827
2331
2904
3549
4266
5059
5930

1.00
2.00
2.00
3.00
4.00

383
819
1314
1961
2637

630
990
1305
1665
2025

EI x 106
2
(in -lbs)
9
35
81
168
303

Where:
1.
ASD Supplements, Tab. 5.4a is from American Wood Council, 2001.
Assume that the joist top is fully lateral supported by diaphragm. (CL = 1.0)
2.
3.
WoodBeam.xls is at www.engineering-international.com

SSI 32MX ( from ICC PFC-5803, page 5 & 6)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)
11 7/8
14
16
18
20
22
24
26
28
30

3.10
3.30
3.60
3.90
4.10
4.40
4.70
5.00
5.20
5.50

5391
6570
7684
8800
9918
11038
12159
13279
14401
15524

2115
2330
2530
2735
2935
3135
3335
3540
3740
3940

SSI 42MX ( from ICC PFC-5803, page 5 & 6)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)
11 7/8
14
16
18
20
22
24
26
28
30

3.80
4.10
4.30
4.60
4.90
5.10
5.40
5.70
6.00
6.20

7592
9274
10863
12456
14051
15649
17248
18849
20450
22052

2060
2350
2620
2895
3165
3440
3710
3985
4255
4530

SSI 43L ( from ICC PFC-5803, page 5 & 6)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)
11 7/8
14
16
18
20
22
24
26
28
30

4.60
4.90
5.20
5.40
5.70
5.90
6.20
6.40
6.70
7.00

__
Page 243 of 533
524

9789
12081
14251
16269
18419
20573
22730
24889
27050
29212

2080
2260
2425
2590
2755
2920
3090
3255
3420
3585

EI x 106
(in2-lbs)
460
667
900
1170
1478
1824
2211
2638
3106
3616

C x 106
(in2-lbs)
9.39
10.99
12.50
14.02
15.55
17.08
18.62
20.15
21.68
23.21

EI x 106
2
(in -lbs)
637
924
1246
1617
2040
2514
3042
3622
4257
4948

C x 106
2
(in -lbs)
9.54
11.15
12.68
14.22
15.77
17.32
18.87
20.42
21.97
23.53

EI x 106
2
(in -lbs)
707
1031
1394
1944
2454
3026
3661
4358
5119
5944

C x 106
2
(in -lbs)
6.81
7.91
8.97
10.05
11.13
12.21
13.30
14.39
15.47
16.56

(cont'd)
DESIGN EQUATIONS
M =

wL
8C D C r

T JI =

V =

22.5w L 4 2.26w L 2
+
EI
d 105

SSI =

5w L 4 w L2
+
384 EI
C

wL
2C D C r

DFL =

5w L
384 EI

( from Trusjoist # 1062, page 21)

( from ICC PFC-5803, page 2)

CHECK JOIST CAPACITIES & DEFLECTIONS


2x No. 2, Douglas Fir-Larch

Deep (in) M (ft-lbs)


4
6
8
10
12

8202
8309
8309
8415
8522

2x No. 1, Douglas Fir-Larch

V (lbs)

LL
(in)

LT
(in)

D+L
(in)

937
950
950
962
974

120.05
32.74
14.22
6.84
3.79

312.66
86.80
37.69
18.45
10.41

288.87
79.81
34.65
16.88
9.48

V (lbs)

LL
(in)

LT
(in)

D+L
(in)

937
950
950
962
974

108.05
27.01
11.87
5.75
3.20

281.39
71.61
31.48
15.51
8.77

259.98
65.84
28.94
14.19
7.99

V (lbs)

LL
(in)

LT
(in)

D+L
(in)

965
969
973
976
979
982
986
990
992
996

2.48
1.69
1.24
0.95
0.74
0.60
0.49
0.41
0.35
0.30

6.71
4.60
3.39
2.61
2.06
1.66
1.37
1.15
0.98
0.84

6.13
4.19
3.09
2.37
1.87
1.51
1.25
1.04
0.89
0.76

V (lbs)

LL
(in)

LT
(in)

D+L
(in)

976
980
982
986
990
993
996
999
1003
1006

1.81
1.25
0.92
0.71
0.56
0.46
0.38
0.32
0.27
0.23

5.00
3.45
2.56
1.98
1.58
1.29
1.07
0.90
0.77
0.67

4.55
3.14
2.33
1.80
1.43
1.16
0.97
0.81
0.70
0.60

V (lbs)

LL
(in)

LT
(in)

D+L
(in)

981
985
989
991
995
998
1002
1004
1008
1012

1.65
1.13
0.83
0.64
0.51
0.41
0.34
0.29
0.25
0.21

4.57
3.14
2.33
1.80
1.43
1.17
0.97
0.82
0.71
0.61

4.15
2.85
2.11
1.63
1.30
1.06
0.88
0.74
0.63
0.55

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.

Deep (in) M (ft-lbs)


4
6
8
10
12

8202
8309
8309
8415
8522

V (lbs)

LL
(in)

LT
(in)

D+L
(in)

937
950
950
962
974

120.05
30.87
13.34
6.43
3.57

312.66
81.84
35.36
17.35
9.79

288.87
75.25
32.51
15.88
8.91

V (lbs)

LL
(in)

LT
(in)

D+L
(in)

963
965
969
973
975
979
982
986
989
992

2.40
1.66
1.24
0.96
0.76
0.62
0.51
0.43
0.37
0.32

6.48
4.51
3.38
2.62
2.09
1.71
1.43
1.21
1.04
0.90

5.93
4.12
3.08
2.39
1.91
1.56
1.30
1.10
0.94
0.81

V (lbs)

LL
(in)

LT
(in)

D+L
(in)

971
975
978
981
985
987
991
995
998
1001

1.75
1.21
0.90
0.70
0.56
0.46
0.38
0.32
0.28
0.24

4.77
3.33
2.49
1.94
1.56
1.28
1.07
0.91
0.78
0.68

4.35
3.03
2.27
1.77
1.41
1.16
0.97
0.82
0.71
0.61

V (lbs)

LL
(in)

LT
(in)

D+L
(in)

981
985
989
991
995
997
1001
1003
1007
1010

1.60
1.11
0.83
0.60
0.48
0.40
0.33
0.28
0.24
0.21

4.43
3.09
2.32
1.69
1.36
1.12
0.94
0.80
0.69
0.61

4.02
2.80
2.10
1.53
1.23
1.01
0.85
0.72
0.62
0.55

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.

2x Structural, Douglas Fir-Larch

Deep (in) M (ft-lbs)


4
6
8
10
12

8202
8309
8309
8415
8522

CHECK
N.G.
N.G.
N.G.
N.G.
N.G.

TJI/L65

SSI 32MX

Deep (in) M (ft-lbs)


11 7/8
14
16
18
20
22
24
26
28
30

8447
8479
8511
8543
8564
8596
8628
8660
8682
8713

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
o.k.

TJI/L90

8543
8575
8596
8628
8660
8692
8713
8745
8777
8799

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
o.k.
o.k.

TJI/H90

8426
8447
8479
8511
8532
8564
8596
8628
8650
8682

N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.

Deep (in) M (ft-lbs)


11 7/8
14
16
18
20
22
24
26
28
30

8500
8532
8554
8586
8618
8639
8671
8703
8735
8756

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
o.k.
o.k.

SSI 43L

Deep (in) M (ft-lbs)


11 7/8
14
16
18
20
22
24
26
28
30

11 7/8
14
16
18
20
22
24
26
28
30

CHECK

SSI 42MX

Deep (in) M (ft-lbs)


11 7/8
14
16
18
20
22
24
26
28
30

Deep (in) M (ft-lbs)

8586
8618
8650
8671
8703
8735
8767
8788
8820
8852

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
o.k.
o.k.
o.k.

Deep (in) M (ft-lbs)


11 7/8
14
16
18
20
22
24
26
28
30

8586
8618
8650
8671
8703
8724
8756
8777
8809
8841

__
Page 244 of 533
524

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
o.k.
o.k.
o.k.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Double Joist Design for Mechanical Equipment Based on NDS 05 / NDS 01, ICC PFC-4354 & PFC-5803
INPUT DATA & DESIGN SUMMARY
L =
30
JOIST SPAN
DL =
DEAD LOAD
26
S =
24
JOIST SPACING
CD =
DURATION FACTOR
1.33
DEFLECTION LIMITATION

AVAILABLE MINIMUM Douglas Fir-Larch SIZES


ft
psf, (w/o self Wt)
in o.c.
(NDS Tab. 2.3.2)

(DL+E) = L / 240

EQUIPMENT WEIGHT
HEIGHT OF MASS CENTER
EQUIPMENT LENGTH
EQUIPMENT WIDTH

22" TJI/H90
22" SSI 43L

( L / 240 , 1.5 in )
3
3
4
6

W=
H=
D=
B=

AVAILABLE MINIMUM TJI SIZES


24" TJI/L90
AVAILABLE MINIMUM SSI SIZES
28" SSI 42MX

kips
ft, 2/3 total height
ft
ft, double joist spacing

SEISMIC LOADS, (CBC 2007 / IBC 2006)


FH = Fp = (KH) MAX{ 0.3SDSIpW , MIN[ 0.4apSDSIp(1+2z/h)/Rp W , 1.6SDSIpW ] }
= 1.3 MAX{ 0.43W , MIN[ 1.15W , 2.30W ]}
=
1.50 W , (SD)
=
1.07 W , (ASD) =
3.21
kips
(ASCE 7-05, Sec. 13.3.1)
F V = KV W =
0.18 W , (ASD) =
0.53
kips, up & down
where

SDS =

0.96

(ASCE 7-05 Sec 11.4.4)

Ip =

1.5

(ASCE Sec. 13.1.3)

ap =

(ASCE Tab. 13.6-1)

Rp =
z=
h=
KH =

1.5
h
36
1.3

(ASCE Tab. 13.6-1)


ft
ft
(ASCE Sec. 13.4.2a)

KV = KH 0.2 SDS / 1.4 =

0.18

wE = (0.5 FH H / B + 0.25 FV) / L =


GRAVITY LOADS
wR =
0.5 (B + S) DL =

234

104

wD = 0.25 W / D =

188

(vertical seismic factor)


plf / joist, at middle of span

plf / joist, full span

plf / joist, at middle of span

ANALYSIS
DESIGN EQUATIONS

M=

2
LD D 2
wR L
+ ( wD + wE )
+
8C D
4C D 8C D

( DL + E ) =

V =

w RL + ( w D + w E ) D
2C D

5w R L 4 ( w D + w E ) L 3D
+
384 EI
48 EI

JOIST PROPERTIES & ALLOWABLE MOMENT & SHEAR


2x No. 2, Douglas Fir-Larch ( ASD Supplements, Tab. 5.4a)
EI x 106
Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)
(in2-lbs)
(CF included)
4
6
8
10
12

1.00
2.00
2.00
3.00
4.00

344
738
1183
1767
2375

630
990
1310
1670
2030

2x No. 1, Douglas Fir-Larch (from WoodBeam.xls)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)
(CF included)

9
33
76
158
285

4
6
8
10
12

2x Structural, Douglas Fir-Larch (ASD Supplements, Tab. 5.4a)


6
EI x 10
Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)
(in2-lbs)
(CF included)
4

1.00

574

630

10

2.00

8
10
12

2.00
3.00
4.00

1225

990

40

1975
2942
3958

1310
1670
2030

91
188
338

TJI/L65 ( from Trusjoist # 1062, page 5)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
11 7/8
14
16
18
20
22
24
26
28
30

3.30
3.60
3.90
4.20
4.40
4.70
5.00
5.30
5.50
5.80

6750
8030
9210
10380
11540
12690
13830
14960
16085
17205

1.00
2.00
2.00
3.00
4.00

1925
2125
2330
2535
2740
2935
3060
2900
2900
2900

EI x 10
(in2-lbs)
450
666
913
1205
1545
1934
2374
2868
3417
4025

630
990
1305
1665
2025

9
35
81
168
303

Where:
1.
ASD Supplements, Tab. 5.4a is from American Wood Council, 2001.
Assume that the joist top is fully lateral supported by diaphragm. (CL = 1.0)
2.
3.
WoodBeam.xls is at www.engineering-international.com

SSI 32MX ( from ICC PFC-5803, page 5 & 6)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)

__

V (lbs)

383
819
1314
1961
2637

EI x 106
(in2-lbs)

11 7/8
14
16
18
20
22
24
26
28
30

Page 245 of 533


524

3.10
3.30
3.60
3.90
4.10
4.40
4.70
5.00
5.20
5.50

5391
6570
7684
8800
9918
11038
12159
13279
14401
15524

2115
2330
2530
2735
2935
3135
3335
3540
3740
3940

EI x 10
(in2-lbs)
460
667
900
1170
1478
1824
2211
2638
3106
3616

C x 106
(in2-lbs)
9.39
10.99
12.50
14.02
15.55
17.08
18.62
20.15
21.68
23.21

(cont'd)
TJI/L90 ( from Trusjoist # 1062, page 5)
Deep (in)
Wt (lbs/ft)
M (ft-lbs)
11 7/8
14
16
18
20
22
24
26
28
30

4.20
4.50
4.70
5.00
5.30
5.60
5.80
6.10
6.40
6.60

9605
11430
13115
14785
16435
18075
19700
21315
22915
24510

TJI/H90 ( from Trusjoist # 1062, page 5)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
11 7/8
14
16
18
20
22
24
26
28
30

V (lbs)

4.60
4.90
5.20
5.40
5.70
6.00
6.30
6.50
6.80
7.10

1925
2125
2330
2535
2740
2935
3060
2900
2900
2900

V (lbs)

10960
13090
15065
17010
18945
20855
22755
24645
26520
28380

1925
2125
2330
2535
2740
2935
3060
2900
2900
2900

EI x 10
(in2-lbs)
621
913
1246
1635
2085
2597
3172
3814
4525
5306

EI x 10
(in2-lbs)
687
1015
1389
1827
2331
2904
3549
4266
5059
5930

SSI 42MX ( from ICC PFC-5803, page 5 & 6)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)
11 7/8
14
16
18
20
22
24
26
28
30

3.80
4.10
4.30
4.60
4.90
5.10
5.40
5.70
6.00
6.20

7592
9274
10863
12456
14051
15649
17248
18849
20450
22052

2060
2350
2620
2895
3165
3440
3710
3985
4255
4530

SSI 43L ( from ICC PFC-5803, page 5 & 6)


Deep (in)
Wt (lbs/ft)
M (ft-lbs)
V (lbs)
11 7/8
14
16
18
20
22
24
26
28
30

4.60
4.90
5.20
5.40
5.70
5.90
6.20
6.40
6.70
7.00

9789
12081
14251
16269
18419
20573
22730
24889
27050
29212

2080
2260
2425
2590
2755
2920
3090
3255
3420
3585

V (lbs)

(DL+E)
(in)

1807
1807
1807
1807
1807

392.69
100.98
43.63
21.04
11.66

V (lbs)

(DL+E)
(in)

1842
1844
1847
1851
1853
1856
1860
1863
1865
1869

7.68
5.30
3.93
3.02
2.39
1.94
1.60
1.34
1.14
0.98

V (lbs)

(DL+E)
(in)

1850
1853
1855
1859
1862
1864
1868
1871
1874
1877

5.55
3.82
2.84
2.19
1.73
1.41
1.16
0.98
0.83
0.71

V (lbs)

(DL+E)
(in)

1859
1862
1865
1868
1871
1873
1877
1879
1882
1886

5.00
3.43
2.54
1.82
1.44
1.17
0.97
0.81
0.69
0.59

EI x 10
(in2-lbs)
637
924
1246
1617
2040
2514
3042
3622
4257
4948

C x 10
(in2-lbs)
9.54
11.15
12.68
14.22
15.77
17.32
18.87
20.42
21.97
23.53

C x 10
(in2-lbs)
6.81
7.91
8.97
10.05
11.13
12.21
13.30
14.39
15.47
16.56

EI x 10
(in2-lbs)
707
1031
1394
1944
2454
3026
3661
4358
5119
5944

CHECK JOIST CAPACITIES & DEFLECTIONS


2x No. 2, Douglas Fir-Larch

Deep (in) M (ft-lbs)


4
6
8
10
12

19023
19108
19108
19192
19277

2x No. 1, Douglas Fir-Larch

V (lbs)

(DL+E)
(in)

1818
1829
1829
1841
1852

392.69
107.10
46.50
22.37
12.40

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.

Deep (in) M (ft-lbs)


4
6
8
10
12

19023
19108
19108
19192
19277

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.

2x Structural, Douglas Fir-Larch

Deep (in) M (ft-lbs)


4
6
8
10
12

19023
19108
19108
19192
19277

V (lbs)

(DL+E)
(in)

1818
1829
1829
1841
1852

353.42
88.35
38.84
18.80
10.46

V (lbs)

(DL+E)
(in)

1844
1847
1851
1854
1856
1860
1863
1867
1869
1872

7.85
5.31
3.87
2.93
2.29
1.83
1.49
1.23
1.03
0.88

V (lbs)

(DL+E)
(in)

1854
1858
1860
1863
1867
1870
1872
1876
1879
1881

5.69
3.87
2.84
2.16
1.70
1.36
1.11
0.93
0.78
0.67

V (lbs)

(DL+E)
(in)

1859
1862
1865
1868
1871
1874
1878
1880
1883
1887

5.14
3.48
2.54
1.93
1.52
1.22
1.00
0.83
0.70
0.60

CHECK
N.G.
N.G.
N.G.
N.G.
N.G.

TJI/L65

SSI 32MX

Deep (in) M (ft-lbs)


11 7/8
14
16
18
20
22
24
26
28
30

19217
19243
19268
19294
19311
19336
19361
19387
19404
19429

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.

TJI/L90

19294
19319
19336
19361
19387
19412
19429
19454
19480
19497

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
o.k.
o.k.
o.k.
o.k.

TJI/H90

19201
19217
19243
19268
19285
19311
19336
19361
19378
19404

N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.

Deep (in) M (ft-lbs)


11 7/8
14
16
18
20
22
24
26
28
30

19260
19285
19302
19327
19353
19370
19395
19420
19446
19463

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
N.G.
o.k.
o.k.

SSI 43L

Deep (in) M (ft-lbs)


11 7/8
14
16
18
20
22
24
26
28
30

11 7/8
14
16
18
20
22
24
26
28
30

CHECK

SSI 42MX

Deep (in) M (ft-lbs)


11 7/8
14
16
18
20
22
24
26
28
30

Deep (in) M (ft-lbs)

19327
19353
19378
19395
19420
19446
19471
19488
19514
19539

CHECK

Deep (in) M (ft-lbs)

__
N.G.
N.G.
N.G.
N.G.
N.G.
o.k.
o.k.
o.k.
o.k.
o.k.

11 7/8
14
16
18
20
22
24
26
28
30

Page 246 of 533


524

19327
19353
19378
19395
19420
19437
19463
19480
19505
19530

CHECK

N.G.
N.G.
N.G.
N.G.
N.G.
o.k.
o.k.
o.k.
o.k.
o.k.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Wood Beam Design Based on NDS 2012


INPUT DATA & DESIGN SUMMARY
MEMBER SIZE
MEMBER SPAN
UNIFORMLY DISTRIBUTED DEAD LOAD

6 x 14
L=
wD =

No. 1, Douglas Fir-Larch

10
112

ft
lbs / ft

lbs / ft

wL =

UNIFORMLY DISTRIBUTED LIVE LOAD

PD1 = 1500 lbs

CONCENTRATED DEAD LOADS

L1 =

(0 for no concentrated load)

ft

PD2 = 3936 lbs


L2 =

ft

L = L / 360

DEFLECTION LIMIT OF LIVE LOAD

Camber => 0.18 inch

Kcr D + L = L / 180

DEFLECTION LIMIT OF LONG-TERM

THE BEAM DESIGN IS ADEQUATE.


Does member have continuous lateral support by top diaphragm ?
(1= yes, 0= no)
0
No
Code
1
2
3
4
5
6
Choice

Duration Factor, CD
Condition
0.90
Dead Load
1.00
Occupancy Live Load
1.15
Snow Load
1.25
Construction Load
1.60
Wind/Earthquake Load
2.00
Impact Load
=>
4
Construction Load

ANALYSIS
DETERMINE REACTIONS, MOMENT, SHEAR
wSelf Wt =
RLeft =
16
lbs / ft

VMax =

3.36

3.51

Code
1
2
3
4
5
6
Choice

RRight =

kips

Designation
Select Structural, Douglas Fir-Larch
No. 1, Douglas Fir-Larch
No. 2, Douglas Fir-Larch
Select Structural, Southern Pine
No. 1, Southern Pine
No. 2, Southern Pine

=>

3.21

kips

MMax =

14.44

ft-kips, at 5.00 ft from left end

ksi

E = Ex =

1600

ksi

Fb =

Fb =

1,350

psi

F = FbE / Fb* =

3.97

Fv =

170

psi

Fb' =

1,639

psi

E' =

1,600

ksi

Fv' =

213

psi

kips, at 13.5 inch from left end

DETERMINE SECTION PROPERTIES& ALLOWABLE STRESSES


b =

5.50

in

E'min =

d =

13.50

in

FbE =

A =

74.3

in2

I =

psi
4
1,128 in

Sx =

167.1

in3

RB =

10.265

lE =

19.7

(ft, Tab 3.3.3 footnote 1)

CD
1.25

CM
1.00

Ct
1.00

580
6605

Ci
1.00

CL
0.98

CHECK BENDING AND SHEAR CAPACITIES


fb = MMax / Sx =
1037 psi
<
fv' = 1.5 VMax / A =

68

< 50

psi

CF
0.99

Fb =

<

CHECK DEFLECTIONS
(L, Max) = 0.00

in, at 5.000 ft from left end,

(Kcr D + L , Max) = 0.18

in, at 4.900 ft from left end

Where

Kcr =

1.50

, (NDS 3.5.2)

DETERMINE CAMBER AT 1.5 (DEAD + SELF WEIGHT)


(1.5D, Max) =
0.18
in, at 4.900 ft from left end

CV
1.00

Cc
1.00

1665.5596

psi

Cr
1.00

1639 psi
Fv'

[Satisfactory]

[Satisfactory]

<
<

L = L / 360
Kcr D + L = L / 180

[Satisfactory]
[Satisfactory]

CHECK THE BEAM CAPACITY WITH AXIAL LOAD


AXIAL LOAD

8.1

kips

THE ALLOWABLE COMPRESSIVE STRESS IS


Fc' = Fc CD CP CF =
804 psi
Where

Fc =

925

CD =

1.60

CF =

0.99

psi
(Lumber only)
2

CP = (1+F) / 2c - [((1+F) / 2c) - F / c]


Fc* = Fc CD CF =

1461

Le = Ke L = 1.0 L =
b =
5.5
in
SF = slenderness ratio =
2
FcE = 0.822 E'min / SF =
E'min =

580

0.5

0.551

<

50

psi
120
21.8
1002

in
[Satisfies NDS 2012 Sec. 3.7.1.4]

psi

ksi

F = FcE / Fc* =
0.686
c =
0.8
THE ACTUAL COMPRESSIVE STRESS IS
fc = F / A =
109
psi

<

THE ALLOWABLE FLEXURAL STRESS IS


Fb' =
2097 psi, [ for CD =

1.6

THE ACTUAL FLEXURAL STRESS IS


fb = (M + Fe) / S = 1304 psi

<

Fc'

[Satisfactory]

Fb'

[Satisfactory]

CHECK COMBINED STRESS [NDS 2012 Sec. 3.9.2]


(fc / Fc' )2 + fb / [Fb' (1 - fc / FcE)]

0.716

<

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wood Post, Wall Stud, or King Stud Design Based on NDS 2005
INPUT DATA

DESIGN SUMMARY

HEIGHT
Effective Length (NDS 3.7)

1 - 4'' x 6'' DOUGLAS FIR-LARCH No. 1

H=
Le x-x =

14.33
14.33

ft
ft, (strong axis bending)

USE:

Le y-y =

14.33

ft, (weak axis bending)

1. CHECK VERTICAL LOADS : fc < Fc' ?


72 psi

PDL =

AXIAL LOAD

800

PLL =
Total
LATERAL LOAD

P=

w=

20

<

208 psi

580

lbs

1,380

lbs

2. CHECK BENDING LOADS : fb < Fb' ?


1129 psi

<

2023 psi

plf

fc

3. CHECK INTERACTION :
F=

406

Max Section
Max Section

lbs, at
M=
V=

10

1660 ft-lbs, at 10.00 ft from bottom


427 lbs, at top end
1

GRADE ( 1, 2, 3, 4, 5, or 6 )

3
999
4
6

No. 1

DRY

pcs, b =
h=

WET / DRY ? (1 = DRY, 2 = WET)

'

Fc

ft, from bottom

SPECIES (1 = DFL, 2 = SP, 3 = LSL, 4 = PSL)

SECTION

[Satisfactory]

lbs

DOUGLAS FIR-LARCH

0.964

<

f bx
1
1 ?
1 f c F cEx F bx'

[Satisfactory]

4. CHECK SHEAR LOADS : fv < Fv' ?


33 psi

in
in

[Satisfactory]

<

288 psi

[Satisfactory]

5. MAXIMUM HORIZONTAL DEFLECTION


=
0.65
in, at 7.73 ft from bottom
( H / 265 )

ANALYSIS
COLUMN BASIC DESIGN STRESSES:
COMPRESSIVE STRESS
MODULUS OF ELASTICITY

Fc =
E=

1500
1700

psi
ksi

BENDING STRESS (X-Axis)

Fbx =

1000

psi

Fv =

180

psi

dy =
dx =
A =
Sx =
Ix =

5.50
3.50
19.25
17.65
48.53

in
in
in2
in3
in4

Le x-x / dy =
Le y-y / dx =

31.3
49.1

SHEAR STRESS (X-Axis)


COLUMN PROPERTIES:
STANDARD DRESSED SIZE
AREA
SECTION PROPERTIES

Abt. x-x

LENGTH-DEPTH RATIO

ADJUSTMENT FACTORS:

Fbx'

Fc'

Fv'

10

E'

DURATION (NDS 2.3.2)

CD

1.60

1.60

1.60

MOISTURE FACTOR

CM

1.00

1.00

1.00

1.00

COLUMN PARAMETER

TEMPERATURE FACTOR

Ct

1.00

1.00

1.00

1.00

BEAM PARAMETER

INCISING FACTOR

Ci

1.00

1.00

1.00

1.00

SIZE FACTOR

CF

1.30

1.10

FLAT USE FACTOR

Cfu

MODULUS OF ELASTICITY

1.00

COLUMN STABILITY
REPETITIVE (1.15 or 1.0)

Cr

1.00

BEAM STABILITY

CL

0.97

620

c =

0.80

RB =

11.544

Fb E =

5583

psi

2080

psi

0.079

Fc* =

211
2640

psi

Fb =

psi

ADJUSTED PROPERTIES:
MODULUS OF ELASTICITY

AXIAL STRESS
BENDING STRESSES

1700

ksi

AXIAL STRESS

__

BENDING STRESS (X-Axis)


ACTUAL STRESSES:

E' =
Fbx' =

2023

Fc' =

208

psi

psi

SHEAR STRESS

Fv' =

288

psi

SHEAR STRESS

fv =

33

psi

fc =

71.7

psi

fbx =

1128.7

psi

Page 249 of 533


524

ksi

< 50

BUCKLING VALUES
FcE =

CP

E'min =

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Shear Wall Design Based on IBC 09 / CBC 10 / NDS 05


INPUT DATA
vdia, WIND =
vdia, SEISMIC =
wDL =
wLL =

LATERAL FORCE ON DIAPHRAGM:


GRAVITY LOADS ON THE ROOF:
DIMENSIONS:

240

plf,for wind

286

plf,for seismic, ASD

262

plf,for dead load

plf,for live load

Lw =

ft , h =

16

ft

L =

11

ft , hp =

ft

<= Sheathing and Single-Floor

PANEL GRADE ( 0 or 1)

MINIMUM NOMINAL PANEL THICKNESS

COMMON NAIL SIZE ( 0=6d, 1=8d, 2=10d )


SPECIFIC GRAVITY OF FRAMING MEMBERS
EDGE STUD SECTION

15/32

in

8d

0.5

pcs, b =

in , h =

SPECIES (1 = DFL, 2 = SP)

DOUGLAS FIR-LARCH

GRADE ( 1, 2, 3, 4, 5, or 6 )

No. 1

STORY OPTION ( 1=ground level, 2=upper level)

in

ground level shear wall

THE SHEAR WALL DESIGN IS ADEQUATE.


DESIGN SUMMARY
BLOCKED 15/32 SHEATHING WITH 8d COMMON NAILS
@ 4 in O.C. BOUNDARY & ALL EDGES / 12 in O.C. FIELD,
5/8 in DIA. x 10 in LONG ANCHOR BOLTS @ 30 in O.C.
HOLD-DOWN FORCES:
TL =
3.69
k ,
TR =
4.27
k
F=
DRAG STRUT FORCES:
0.57
k
EDGE STUD:
2 - 2'' x 6'' DOUGLAS FIR-LARCH No. 1, CONTINUOUS FULL HEIGHT.
=
SHEAR WALL DEFLECTION:
0.66
in

(USE PHD5-SDS3 SIMPSON HOLD-DOWN)

ANALYSIS
CHECK MAX SHEAR WALL DIMENSION RATIO
DETERMINE REQUIRED CAPACITY

L/B =
vb =

350

1.8
plf,

<

3.5

Side Diaphragm Required, the Max. Nail Spacing =

[Satisfactory]
4

in )

THE SHEAR CAPACITIES PER IBC Table 2306.3 / SDPWS-08 Table 4.3A with ASD reduction factor 2.0)
Blocked Nail Spacing
Min.
Min.
Panel Grade
Boundary & All Edges
Common Penetration Thickness
Nail
(in)
(in)
6
4
3
2
Sheathing and Single-Floor
8d
1 1/2
15/32
260
380
490
640

Note:

1. The indicated shear numbers have reduced by specific gravity factor per IBC note a.
2. Since the wall is blocked, SDPW-08 Table 4.3.3.2 does not apply.
F = (L-Lw) MAX( vdia, WIND, 0vdia, SEISMIC ) =

DETERMINE DRAG STRUT FORCE:

0.57

( 0

) (Sec. 1633.2.6)

DETERMINE MAX SPACING OF 5/8" DIA ANCHOR BOLT (NDS 2005, Tab.11E)
5/8 in DIA. x 10 in LONG ANCHOR BOLTS @ 30 in O.C.

WIND

240

42240

Net Uplift
(lbs)

Left

21035

0.9

TL =

3694

Right

15271

0.9

TR =

4271

Left

21035

2/3

TL =

3135

Right

15271

2/3

TR =

3562

Holddown
SIMPSON

52179

Safety
Factors

SD
S

230

286

Resisting
Moments (ft-lbs)

D5
-

SEISMIC

Overturning
Moments (ft-lbs)

PH

THE HOLD-DOWN FORCES:


Wall Seismic
vdia
at mid-story (lbs)
(plf)

(TL & TR values should include upper level UPLIFT forces if applicable)
CHECK MAXIMUM SHEAR WALL DEFLECTION: ( IBC Section 2305.3 / SDPWS-08 4.3.2)

= Be nding + Shear + Nail


Where:

vb =
A=
t=

slip

350
16.50
0.298

CHECK EDGE STUD CAPACITY

+ C hord
plf , ASD
in2
in

splice slip

Lw =
h =
en =

hd a
8v b h 3 v bh
+
+ 0.75he n +
EAL w Gt
Lw
9
16
0.012

ft
ft
in

__

5.42

kips, (this value should include upper level DOWNWARD loads if applicable)
psi

1700

ksi

CF =

CP =

0.15

1.10

'

404

Fc =

Page 250 of 533


524

0.686

in

[Satisfactory]
(ASCE 7-05 12.8.6)
I=
Cd =
4
1
,(ASCE 7-05 Tab 12.2-1 & Tab 11.5-1)
0.02

hsx

, (ASCE 7-05 Tab 12.12-1)

1500

1.60

<

in, ASD

xe,allowable, ASD =

a =

Fc =
E=

0.665

E = 1.7E+06 psi
G = 9.0E+04 psi
da =
0.15
in

Pmax =

CD =

A=
psi

16.5

>
[Satisfactory]

fc =

in2
329

psi

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wood Diaphragm Design Based on NDS 2005


INPUT DATA
wL, WIND =
wL, SEISMIC =
LATERAL FORCE ALONG B SIDE:
wB, WIND =
wB, SEISMIC =

256

plf,for wind

300

plf,for seismic

256

plf,for wind

343

plf,for seismic

DIMENSIONS:

LATERAL FORCE ALONG L SIDE:

L=

240

ft , B =

110

ft

B1 =

45

ft , B2 =

40

ft

<= Sheathing and Single-Floor

PANEL GRADE ( 0 or 1)

MINIMUM NOMINAL FRAMING WITH ( 2 or 3) =


=

MINIMUM NOMINAL PANEL THICKNESS

COMMON NAIL SIZE ( 0=6d, 1=8d, 2=10d )

in

15/32

in

8d

SPECIFIC GRAVITY OF FRAMING MEMBERS


0.43
FRAMING OF Douglas-Fir-Larch OR Southern Pine ?

Yes

DESIGN SUMMARY
A1:
(2) - 10 ft x 110 ft
BLOCKED 15/32 SHEATHING WITH 8d COMMON NAILS
@ 4 in O.C. BOUNDARY / 6 in O.C. EDGES / 12"O.C. FIELD.

A2:

(2) - 14 ft x 110 ft
BLOCKED 15/32 SHEATHING WITH 8d COMMON NAILS
@ 6" O.C. BOUNDARY & EDGES / 12"O.CFIELD.

A3:

(1) - 192.00 ft x 110 ft


UNBLOCKED 15/32 SHEATHING WITH 8d COMMON NAILS
@ 6" O.C. ALL EDGES / 12"O.CFIELD.
THE CHORD FORCES:
TL = CL = 19.64
THE DRAG STRUT FORCES:
F1 =
9.16
THE MAXIMUM DIAPHRAGM DEFLECTION:

k ,
k ,

TB = CB =
F2 =
=

2.16
36.65
3.30

k
k
in

ANALYSIS
THE DIAPHRAGM IS CONSIDER FLEXIBLE IF ITS MAXIMUM LATERAL DEFORMATION IS MORE THAN TWO TIMES THE AVERAGE SHEAR
WALL DEFLECTION OF THE ASSOCIATED STORY. WITHOUT FURTHER CALCULATIONS, ASSUME A FLEXIBLE DIAPHRAGM HERE.
FROM THE TABLE 3.1 IN ASD MANUAL SUPP 01, PAGE SP-12, THE PANEL BENDING STRENGTH CAPACITY IS 355 in-lbs/ft, THAT IS THE
DIAPHRAGM CAN RESISTS 59 psf GRAVITY LOADS (DL+LL) AT 2'-0" o.c. SPACING SUPPORTS.
THE MAX DIAPHRAGM DIMENSION RATIO

L/B =

2.2

< 3, [satisfactory]

THE MAX SHEAR FORCE ALONG B SIDE

vL =

327

plf, ( Boundary Spacing =

THE MAX SHEAR FORCE ALONG L SIDE

vB =

79

plf, ( Required Boundary/Edges Nail Spacing for Case 3 =

in, Edges ReqD =

THE ALLOWABLE SHEAR FORCE FOR CASE 1 @ 6 in NAIL SPACING

v1 =

300

plf, L1 =

110.0

ft

THE MAX ALLOWABLE UNBLOCKED SHEAR FORCE FOR CASE 1

v1 =

265

plf, L2 =

97.2

ft

THE SHEAR CAPACITIES PER IBC Table 2306.2.1 / SDPWS-08 Table 4.2A with ASD reduction factor 2.0 :
Blocked Nail Spacing
Min.
Min.
Member
Panel Grade
Boundary / Other Edges
Common PenetrationThickness Width
Nail
(in)
(in)
(in)
6/6
4/6
2.5 / 4
2/3
Sheathing and Single-Floor
8d
1 1/2
15/32
3
300
400
600
675

in )

in )

Unblocked
Case 1
265

Others
200

Note: The indicated shear numbers have reduced by specific gravity factor per SDPWS-08 Table 4.2A note 2.
THE CHORD FORCES:

TL = CL = ( wLL2 ) / ( 8B ) =

THE DRAG STRUT FORCES:

19.64

TB = CB = ( wBB2 ) / ( 8L ) =

F1 = 0.5 (B-2B1) MAX( v1, WIND, 0v1, SEISMIC ) =

9.16

F2 = B2 MAX( v1, WIND, 0v1, SEISMIC ) =

36.65

2.16

0 = 2.8

(ASCE 7-05
Table 12.2-1)

THE MAXIMUM DIAPHRAGM DEFLECTION: (IBC 2305.2.2 , / SDPWS-08 4.2.2)

= Bending + Shear + Nail


Where:

Note:

slip

+ Chord

splice slip

5v L L 3 v LL
+
+ 0.188 Le n +
8 EAB 4 Gt

( DCx )

3.301

in

2B

vL =
327
plf
L=
240
ft
E = 1.7E+06 psi
2
A = 21.75 in
B=
110
ft
G = 9.0E+04 psi,(UBC97 Page3-421)
t = 0.298 in,(UBC97 Page3-420)
en = 0.037 in,(UBC97 Page3-422) (Dcx) = 45.00 in
The deflection, , above is based on completely blocked. For unblocked diaphragm, 2.4 should be used.

Daniel
Tian Li

PROJECT :

PAGE :

CLIENT :

DESIGN BY :

JOB NO. :

DATE :

REVIEW BY :

Subdiaphragm Design Based on ASCE 7-05

INPUT DATA
L=
B=
hr =

Length
Width
Roof Height

hP =

4
112

psf

SDS =
I=
vallowable =

0.54
1
720

plf

Wall Weight

Importance Factor
Diaphragm Shear Capacity

ft
ft
ft

WP =

Parapet Height

Coefficient

60
46
28

ft

ANALYSIS
The subdiaphragms comply with 2.5:1 of max. length-to-width rario. (ASCE 7-05, 12.11.2.2.1)
The wall anchor force is given by ASCE 7-05, 12.11.2 as

F P = MAX 0.8S DS I W p
Where :

Fmin

( hr +h p )

2h r

, 400 S DS I , F min =

885 plf

plf

280

(ASCE 7-05, 12.11.2c)

Wood subdiaphragm shear :


v=

0.5 F PL
1.4 B

plf, for ASD


412
vallowable
<
Satisfactory to use diaphragm nailing for subdiaphragm.

Chord force :

T = C = F PL
8B

8.66

k, (Indicated force has NOT been reduced for ASD)

Reaction force :
R=

F PL
2

26.54 k
(Indicated force has NOT been reduced for ASD)

__
Page 252 of 533
524

Daniel
T. Li

PROJECT :

PAGE :

CLIENT :

DESIGN BY :
REVIEW BY :

JOB NO. :

DATE :

Subdiaphragm Design Based on UBC 97


INPUT DATA
Length
Width
Roof Height

L=
B=
hr =

60
46
28

ft
ft
ft
ft

hP =

WP =

112

Ca =
Coefficient
Seismic Zone (2A, 2B, 3, 4)
IP =
Importance Factor
vallowable =
Diaphragm Capacity

0.44
4
1

Parapet Height
Wall Weight

720

psf

plf (ASD)

ANALYSIS
Rp
=
3
ap
=
1.5
The subdiaphragms comply with 2.5:1 max. length-to-width rario. (Sec.1633.2.9,UBC 97)

Fp=

a pC a I p
4a C I pw p
h
1+ 3 x wp = p a
=
hr
Rp
Rp

99

psf

Check minimum wall-roof anchorage force : (Sec.1633.2.8.1 & 1611.4, UBC97)


w= F

( h r +h p )

2h r

Thus, w

1802

plf

1802

plf

>

420

plf

Wood subdiaphragm shear : (Sec.1633.2.8.1 item 5, UBC97)


0.5wL
, for zone 3 or 4
1.4 B
=
plf, for ASD
714
v=
0.5wL
<
720
plf
, for zone 1 or 2
1.4 B
Use diaphragm nailing for subdiaphragm is adequate.
0.85

Chord force :
T =C=

wL 2
8B

Steel tie/reaction force :


1.4

R=

wL
,
2

wL
,
2

17.63

kips, (for SD)

12.59

kips, (for ASD)

(Sec.1633.2.8.1 item 4, UBC97)

for zone 3 or 4
=

75.69

kips, (SD) =

__

for zone 1 or 2

Page 253 of 533


524

54.07 kips, (for ASD)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Top Plate Connection Design Based on NDS 2005


INPUT DATA & DESIGN SUMMARY
DIAPHRAGM CHORD FORCE RESISTED BY THE TOP PLATE
T=C=
NAIL TYPE ( 0=Common Wire, 1=Box, 2=Sinker )
NAIL PENNY-WEIGHT ( 12d, 16d, 20d )
LUMBER TYPE
( 0=Douglas Fir-Larch, 1=Douglas Fir-Larch(N),
2=Hem-Fir(N), 3=Hem-Fir, 4=Spruce-Pine-Fir)
LUMBER GRADE ( 0=Select Structural, 1=No.1 & Btr, 2=No.1, 3=No.2,
4=No.3, 5=Stud, 6=Construction, 7=Standard, 8=Utility)
TOP PLATE SIZE
Double
2
x

15
0
16d
0

CD =
CM =
Ct =

LOAD DURATION FACTOR ( Tab 2.3.2, NDS 2005, Page 8 )


WET SERVICE FACTOR ( Tab 10.3.3, NDS 2005, Page 58 )
TEMPERATURE FACTOR ( Tab 10.3.4, NDS 2005, Page 58 )

k
Common Wire Nail
Douglas Fir-Larch, G=0.5

No.1

No.1, Douglas Fir-Larch, G=0.5

1.6
1.0
1.0

Use CMSTC16 with 32-16d sinkers, Each Side.

ANALYSIS
DESIGN VALUE FOR TENSION (Tab 4A, NDS 2005 SUPP, Page 32)
AREA OF CROSS SECTION FOR ONE 2 x 6 MEMBER
SIZE FACTOR (Tab 4A, NDS 2005 SUPP, Page 30)
ALLOWABLE TENSION CAPACITY FOR ONE 2 x 6 ONLY

Ft =
675
psi
2
A =
8.25 in
CF =
1.30
T' = AFtCDCMCtCF =

11.58

< T, SIMPSON STRAP REQUIRED.

L =
ts =
p =
THE PENETRATION OF THE NAIL INTO THE MAIN MEMBER
D =
NAIL DIAMETER
THE PENETRATION FACTOR (Note 3, Tab 11N, NDS 2005, Page 97) Cd =

NAIL LENGTH

SIDE MEMBER THICKNESS

in
in
in
1.99
0.162 in
3 1/2

1 1/2

1.00

THE NOMINAL DESIGN VALUE FOR SINGLE SHEAR IS TABULATED IN NDS 2005 TABLE 11N, PAGE 97, AS
Z =
141
lbf
THE ALLOWABLE LATERAL DESIGN VALUE FOR THE ONE NAIL IS

Z' =

ZCDCMCtCd

n =
=
T / Z'
THE NUMBER OF NAILS REQUIRED IS
T - T' =
THE MIN. FORCE RESISTED BY THE SIMPSON STRAP
3.42
Use CMSTC16 with 32-16d sinkers, Each Side.

__

226

66.5

Technical References:
1. "National Design Specification, NDS", 2005 Edition, AF&AP, AWC, 2005.
2. Alan Williams: "Structural Engineering Reference Manual", Professional Publications, Inc, 2001.

Page 254 of 533


524

lbf
67

Nails

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Bolt Connection Design Based on NDS 2012


INPUT DATA & DESIGN SUMMARY
AXIAL TENSILE FORCE (ASD)

T=

5.3

NUMBER OF BOLTS

BOLT DIAMETER
BOLT SPACING

n=
I=
S=

3/4
3

END DISTANCE OF WOOD

En =

in

END DISTANCE OF STEEL

En,s =

1.5

in

LUMBER TYPE

( 0=Douglas Fir-Larch, 1=Douglas Fir-Larch(N),


2=Hem-Fir(N), 3=Hem-Fir, 4=Spruce-Pine-Fir)
(
2
)
2
5

LUMBER SIZE
STRAP SIZE

thk. x
width x

in

Douglas Fir-Larch, G=0.5

6
1/4

width
thk.

LOAD DURATION FACTOR ( Tab 2.3.2, NDS 2012)

CD =

WET SERVICE FACTOR ( Tab 10.3.3, NDS 2012)

CM =

1.0

TEMPERATURE FACTOR ( Tab 10.3.4, NDS 2012)

Ct =

1.0

1.6

THE CONNECTION DESIGN IS ADEQUATE.

ANALYSIS
CHECK STEEL STRAP CAPACITIES (AISC 360-10, ASD)
in2, yielding criterion
Ag =
1.25
Tallow =

0.6 Fy Ag =

27.00

Fy =

>

>

>

36.00

ksi

[Satisfactory]

(0.6 from 1/:t, Typ.)


An =

1.03

Tallow =

in2, fracture criterion

0.5 Fu An =

Av =

1.33

29.91

Fu =

ksi

in2, block shear

Tallow =

0.3 Fu Av + 0.5 Fu (0.5 An) =

38.06

rmin =

t / (12)0.5 =

in

L / rmin =

58.00

[Satisfactory]

0.072

55

<

T
L=

300

[Satisfactory]

[Satisfactory]
Max (En , S ) =

in

(AISC 360-10 D1)

CHECK EDGE, END, & SPACING DISTANCE REQUIREMENTS (NDS 2012, Table 11.5.1A, Table 11.5.1B, & Table 11.5.1C)
Eg =

2.75

in

>

1.5 D

[Satisfactory]

En =

in

>

3.5 D

[Satisfactory]

S=

in

>

3D

[Satisfactory]

CHECK WOOD CAPACITY


C' = Min (C'1 , C'2 , C'3) =
where

Cg

0.762

, (geometry factor, NDS 2012, 11.5.1)

C'1 = (actual end distance) / (min end distance for full design value) = En / 7D =

0.762

C'2 = (actual shear area) / (min shear area for full design value) =

1.000

C'3 = (actual spacing) / (min spacing for full design value) = S / 4D =

1.000

m 1 m 2 n

1 R EA
1 m
n 1
n 1m 1 2 n


R
m
m
EA

where

Z'II =

, (group action factor, NDS 2012, 10.3.6)

n=

REA = Min [(EsAs/EmAm) , (EmAm/EsAs)] =

EsAs =

37500000 lbs, (NDS 2012, Table 10.3.6C)

J = 180000 D1.5 =

tm =

u = 1+J S/2 [1 / EmAm + 1 / EsAs] =

EmAm =

23100000 lbs, (NDS 2012, Table 10.3.6C)

n ZII CD CM Ct Cg C' =

where

0.988

ZII =

1470

in

5.309

kips

m = u - (u2 - 1)0.5 =

>

0.616

116913.4

0.855

[Satisfactory]

lbs / bolt, (interpolated from NDS 2012, Table 11B)

Technical References:
1. "National Design Specification, NDS", 2012 Edition, AF&AP, AWC, 2012.
2. Alan Williams: "Structural Engineering Reference Manual", Professional Publications, Inc, 2001.

1.012

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Nailer Connection Design Based on NDS 2005


INPUT DATA & DESIGN SUMMARY
AXIAL TENSILE FORCE (ASD)
NUMBER OF STUDS
THREAD STUD DIAMETER
THREAD STUD SPACING

T=
n=
=
S=

END DISTANCE OF WOOD

En =

NAILER TYPE

( 0=Douglas Fir-Larch, 1=Douglas Fir-Larch(N),


2=Hem-Fir(N), 3=Hem-Fir, 4=Spruce-Pine-Fir)
4

NAILER SIZE

thk.

8
6
3/4
12

in

in

Douglas Fir-Larch, G=0.5

width
in2

SECTION AREA OF STEEL MEMBER

As =

11.8

LOAD DURATION FACTOR ( Tab 2.3.2, NDS 2005, Page 8 )


WET SERVICE FACTOR ( Tab 10.3.3, NDS 2005, Page 58 )

CD =
CM =

1.6
1.0

TEMPERATURE FACTOR ( Tab 10.3.4, NDS 2005, Page 58 )

Ct =

1.0

GROUP ACTION FACTOR APPLY? ( 0 = No, 1 = Yes)

Yes, ( Cg =

0.719

, NDS 2005, 10.3.6)

(If T is drag/collector force or stud spacing less than 12" o.c., the group action factor Cg must apply.)

THE CONNECTION DESIGN IS ADEQUATE.

ANALYSIS
CHECK EDGE, END, & SPACING DISTANCE REQUIREMENTS (NDS 2005, Table 11.5.1A, Table 11.5.1B, & Table 11.5.1C)
Eg =

2.75

in

>

1.5 D

[Satisfactory]

En =

in

>

3.5 D

[Satisfactory]

S=

12

in

>

3D

[Satisfactory]

CHECK WOOD CAPACITY


C = Min (C1 , C2 , C3) =
where

Cg =

where

0.762
1.000

C3 = (actual spacing) / (min spacing for full design value) = S / 4D =

4.000

n=

E mA m =

where

m 1 m 2 n

n 1+ R EA m n (1+m ) 1+m 2 n

tm =

, (geometry factor, NDS 2005, 11.5.1, page 76)

C2 = (actual shear area) / (min shear area for full design value) =

E sA s =

Z'II

0.762

C1 = (actual end distance) / (min end distance for full design value) = En / 7D =

0.719

= 180000 D

3.4E+08 lbs
3.5

1.5

116913

u = 1+ S/2 [1 / EmAm + 1 / EsAs] =

in

__
9.050

kips

1.028

2
0.5
m = u - (u - 1) = 0.789

2.7E+07 lbs, (Em fr NDS, Tab.10.3.6C)

1720

, (group action factor, NDS 2005, 10.3.6, page 60)

REA = Min [(EsAs/EmAm) , (EmAm/EsAs)] =

n ZII CD CM Ct Cg C =
ZII =

1+ R EA
1 m

>

[Satisfactory]

lbs / stud, (interpolated from Tab 11E, NDS 2005, Page 85 or Tab 11B, NDS 2005, Page 82)

Technical References:
1. "National Design Specification, NDS", 2005 Edition, AF&AP, AWC, 2005.
2. Alan Williams: "Structural Engineering Reference Manual", Professional Publications, Inc, 2001.

Page 256 of 533


524

0.079

PROJECT :
CLIENT :
JOB NO. :

DATE :

PAGE :
DESIGN BY :
REVIEW BY :

Wood Shear Wall with an Opening Based on IBC 09 / CBC 10 / NDS 05


INPUT DATA
vdia, WIND =
vdia, SEISMIC =

LATERAL FORCE ON DIAPHRAGM:


(SERVICE LOADS)

DIMENSIONS:

151

plf,for wind

151

plf,for seismic, ASD

L1 =

ft , L2 =

ft , L3 =

ft

H1 =

2.67

ft , H2 =

ft , H3 =

2.33

ft

pcs, b =

in , h =

in

in

KING STUD SECTION

SPECIES (1 = DFL, 2 = SP)


GRADE ( 1, 2, 3, 4, 5, or 6 )
EDGE STUD SECTION

GRADE ( 1, 2, 3, 4, 5, or 6 )
=

DOUGLAS FIR-LARCH

No. 1

pcs, b =

SPECIES (1 = DFL, 2 = SP)


PANEL GRADE ( 0 or 1)

in , h =

DOUGLAS FIR-LARCH

No. 1

<= Sheathing and Single-Floor

MINIMUM NOMINAL PANEL THICKNESS

COMMON NAIL SIZE ( 0=6d, 1=8d, 2=10d )


SPECIFIC GRAVITY OF FRAMING MEMBERS
STORY OPTION ( 1=ground level, 2=upper level)

15/32
2

in
10d

THE SHEAR WALL DESIGN IS ADEQUATE.

0.5
2

upper level shear wall

DESIGN SUMMARY
BLOCKED 15/32 SHEATHING WITH 10d COMMON NAILS
@ 6 in O.C. BOUNDARY & ALL EDGES / 12 in O.C. FIELD,
SILL PLATE ATTACHMENT 16d AT 6" O.C.
HOLD-DOWN FORCES:
TL =
1.42
k ,
TR = 1.42 k
(USE CS16 SIMPSON HOLD-DOWN)
F=
MAX STRAP FORCE:
0.56
k
(USE SIMPSON CS22 OVER WALL SHEATHING WITH FLAT BLOCKING)
KING STUD:
2 - 2'' x 6'' DOUGLAS FIR-LARCH No. 1, CONTINUOUS FULL HEIGHT.
EDGE STUD:
1 - 4'' x 6'' DOUGLAS FIR-LARCH No. 1, CONTINUOUS FULL HEIGHT.
=
SHEAR WALL DEFLECTION:
0.24
in

__
Page 257 of 533
524

cont'd

ANALYSIS
CHECK MAX SHEAR WALL DIMENSION RATIO

h/w =

1.3

<

3.5

[Satisfactory]

DETERMINE FORCES & SHEAR STRESS OF FREE-BODY INDIVIDUAL PANELS OF WALL


INDIVIDUAL PANEL

W (ft)

H (ft)

MAX SHEAR STRESS (plf)

NO.

FORCE (lbf)

NO.

3.00

2.33

65

F1

194

F13

FORCE (lbf)

654

2.00

2.33

281

F2

561

F14

654
1157

2.00

2.33

281

F3

194

F15

3.00

2.33

65

F4

654

F16

503

3.00

2.00

252

F5

755

F17

503
1157

3.00

2.00

252

F6

561

F18

3.00

2.00

252

F7

561

F19

455

3.00

2.00

252

F8

755

F20

455

3.00

2.67

100

F9

150

F21

770

10

2.00

2.67

288

F10

503

F22

300

11

2.00

2.67

288

F11

503

F23

455

12

3.00

2.67

100

F12

150

F24

300

DETERMINE REQUIRED CAPACITY

vb =

288

plf,

Side Panel Required, the Max. Nail Spacing =

in )

THE SHEAR CAPACITIES PER IBC Table 2306.3 / SDPWS-08 Table 4.3A with ASD reduction factor 2.0)
Blocked Nail Spacing
Min.
Min.
Panel Grade
Boundary & All Edges
Common Penetration Thickness
Nail
(in)
(in)
6
4
3
2
Sheathing and Single-Floor
10d
1 5/8
15/32
310
460
600
770

Note: The indicated shear numbers have reduced by specific gravity factor per IBC note a.
DETERMINE FLOOR SILL PLATE ATTACHMENT (NDS 2005, Table 11Q & Table 11L)
SILL PLATE ATTACHMENT 16d AT 6" O.C.

SEISMIC
WIND

Overturning
Moments (ft-lbs)

144

151

Resisting
Moments (ft-lbs)

14238

151

13590

Net Uplift
(lbs)

Safety
Factors

Left

0.9

TL =

1424

Right

0.9

TR =

1424

Left

2/3

TL =

1359

Right

2/3

TR =

1359

Holddown
SIMPSON

CS
16

THE HOLD-DOWN FORCES:


Wall Seismic
vdia
at mid-story (lbs)
(plf)

(TL & TR values should include upper level UPLIFT forces if applicable)
CHECK MAXIMUM SHEAR WALL DEFLECTION: ( IBC Section 2305.3 / SDPWS-08 4.3.2)

= Be nding + Shear + Nail


Where:

vb =
A=
t=

slip

288
16.50
0.298

+ C hord
plf , ASD
in2
in

splice slip

Lw =
h =
en =

hd a
8v b h 3 v bh
+
+ 0.75he n +
EAL w Gt
Lw
10
9
0.000

ft
ft
in

E=
G=
da =

0.238

1.7E+06 psi
9.0E+04 psi
0.15
in

<

in, ASD

xe,allowable, ASD =

0.386

in

[Satisfactory]
(ASCE 7-05 12.8.6)
I=
Cd =
4
1
,(ASCE 7-05 Tab 12.2-1 & Tab 11.5-1)
a =

0.02

hsx

, (ASCE 7-05 Tab 12.12-1)


CHECK KING STUD CAPACITY
Pmax =

0.50

Fc =

1500

psi

CD =

1.60

CP =

0.43

E=

1700

ksi

CF =

1.10

F c' =

1146

kips
A=
psi

16.50

>

in

fc =

31

psi

74

psi

[Satisfactory]
CHECK EDGE STUD CAPACITY
Pmax =

1.42

Fc =

1500

psi

CD =

1.60

CP =

0.43

E=

1700

ksi

CF =

1.10

F c' =

1146

kips, (this value should include upper level DOWNWARD loads if applicable)
A=
psi

19.25

>
[Satisfactory]

__
Page 258 of 533
524

fc =

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Perforated Shear Wall Design Based on IBC 09 / CBC 10 / NDS 05


INPUT DATA
LATERAL FORCE ON DIAPHRAGM (SERVICE LOADS):

vdia, WIND =
vdia, SEISMIC =

151

plf,for wind

130

plf,for seismic, ASD

NUMBER OF OPENINGS
L=
DIMENSIONS:

n=
72

ft

H=

18

ft

h=

10

ft, (the highest opening)


H to L

ratio

ft

3.00

ok

6.5

ft

2.77

ok

5.5

ft

3.27

ok

7.5

ft

2.40

ok

6.33

ft

2.84

ok

6.67

ft

2.70

ok

38.5

KING STUD SECTION


2

ft

in , h =

in

DOUGLAS FIR-LARCH

GRADE ( 1, 2, 3, 4, 5, or 6 )

No. 1

EDGE STUD SECTION


1

PANEL GRADE ( 0 or 1)

pcs, b =

SPECIES (1 = DFL, 2 = SP)

<= Sheathing and Single-Floor

MINIMUM NOMINAL PANEL THICKNESS

15/32

COMMON NAIL SIZE ( 0=6d, 1=8d, 2=10d )

SPECIFIC GRAVITY OF FRAMING MEMBERS

pcs, b =

in , h =

in

SPECIES (1 = DFL, 2 = SP)

DOUGLAS FIR-LARCH

GRADE ( 1, 2, 3, 4, 5, or 6 )

Dense No.1

in

THE SHEAR WALL DESIGN IS ADEQUATE.

10d

0.5

STORY OPTION ( 1=ground level, 2=upper level)

ground

DESIGN SUMMARY
BLOCKED 15/32 SHEATHING WITH 10d COMMON NAILS
@ 4 in O.C. BOUNDARY & ALL EDGES / 12 in O.C. FIELD,
5/8 in DIA. x 10 in LONG ANCHOR BOLTS @ 28 in O.C.
HOLD-DOWN FORCES:
TL =
6.62
k ,
TR = 6.62 k
(USE HDQ8-SDS3 SIMPSON HOLD-DOWN)
F=
MAX STRAP FORCE:
2.76
k
(USE SIMPSON CMSTC16 OVER WALL SHEATHING WITH FLAT BLOCKING)
KING STUD:
2 - 3'' x 6'' DOUGLAS FIR-LARCH No. 1, CONTINUOUS FULL HEIGHT.
EDGE STUD:
1 - 6'' x 6'' DOUGLAS FIR-LARCH Dense No.1, CONTINUOUS FULL HEIGHT.
=
SHEAR WALL DEFLECTION:
0.43
in

ANALYSIS
CHECK MAX SHEAR WALL DIMENSION RATIO

h/w =

3.3

<

3.5

(allow reduced 2w/h, SDPWS-08 4.3.4)

[Satisfactory]

DETERMINE SHEAR RESISTANCE ADJUSTMENT FACTOR, C o


Percentage of Full-Height Sheathing

Maximum Opening Height

Co

0.768

53%

, (SDPWS-08 4.3.3.5)

0.56 H

, (SDPWS-08 Table 4.3.3.5)

DETERMINE REQUIRED CAPACITY (SDPWS-08 4.3.3.5)


v b = V / (C o L

)=

368

plf,

<

870

Side Panel Required, the Max. Nail Spacing =

plf, (SDPWS-08 4.3.5.3.3)

in )

[Satisfactory]

THE SHEAR CAPACITIES PER IBC Table 2306.3 / SDPWS-08 Table 4.3A with ASD reduction factor 2.0)
Blocked Nail Spacing
Min.
Min.
Panel Grade
Boundary & All Edges
Common Penetration Thickness
Nail
(in)
(in)
6
4
3
2
Sheathing and Single-Floor
10d
1 5/8
15/32
310
460
600
770

Note: The indicated shear numbers have reduced by specific gravity factor per IBC note a.
DETERMINE MAX SPACING OF 5/8" DIA ANCHOR BOLT (NDS 2005, Tab.11E)
5/8 in DIA. x 10 in LONG ANCHOR BOLTS @ 28 in O.C.

SEISMIC
WIND

130
151

2074

Overturning
Moments (ft-lbs)
168480
195696

Resisting
Moments (ft-lbs)

Safety
Factors

Net Uplift
(lbs)

Left

0.9

TL =

Right

0.9

TR =

5696

Left

2/3

TL =

6616

2/3

TR =

6616

Right

5696

Holddown
SIMPSON

HD
Q
8SD
S3

THE HOLD-DOWN FORCES:


Wall Seismic
vdia
at mid-story (lbs)
(plf)

(TL & TR values should include upper level UPLIFT forces if applicable)

(cont'd)
CHECK MAXIMUM SHEAR WALL DEFLECTION: ( IBC Section 2305.3 / SDPWS-08 4.3.2)

= Be nding + Shear + Nail


Where:

vb =
A=
t=

slip

368
16.50
0.298

+ C hord

splice slip

plf , ASD
in2
in

hd a
8v b h 3 v bh
+
+ 0.75he n +
EAL w Gt
Lw

Lw =
38.5
ft
h =
18
ft
en = 0.00E+00 in

0.433

E = 1.7E+06 psi
G = 9.0E+04 psi
da =
0.15
in

<

in, ASD

xe,allowable, ASD =

0.771

in

[Satisfactory]
(ASCE 7-05 12.8.6)
I=
Cd =
4
1
,(ASCE 7-05 Tab 12.2-1 & Tab 11.5-1)
a =

0.02

hsx

, (ASCE 7-05 Tab 12.12-1)


CHECK KING STUD CAPACITY (SDPWS-08 4.3.6.1.2)
Pmax =

5.16

kips

Fc =

1500

psi

E=

1700

ksi

CD =
CF =

1.60

CP =

0.12

1.10

'

322

Fc =

A=

27.50

>

psi

in2

fc =

187

psi

219

psi

[Satisfactory]
CHECK EDGE STUD CAPACITY (SDPWS-08 4.3.6.1.2)
Pmax =

6.62

kips, (this value should include upper level DOWNWARD loads if applicable)

Fc =

1200

psi

E=

1700

ksi

CD =
CF =

1.60

CP =

0.17

1.00

'

318

Fc =

A=
psi

30.25

>
[Satisfactory]

fc =

in2

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Toe-Nail Connection Design Based on NDS 2005


INPUT DATA & DESIGN SUMMARY
NAIL TYPE ( 0=Common Wire, 1=Box, 2=Sinker )
NAIL PENNY-WEIGHT ( 6d, 7d, 8d, 10d, 12d, 16d, 20d, 30d, 40d, 50d, 60d )
LUMBER SPECIES ( 0=Douglas Fir-Larch, 1=Douglas Fir-Larch(N),
2=Hem-Fir(N), 3=Hem-Fir, 4=Spruce-Pine-Fir)

CD =
CM =
Ct =

LOAD DURATION FACTOR ( Tab 2.3.2, NDS 2005, Page 8 )


WET SERVICE FACTOR ( Tab 10.3.3, NDS 2005, Page 58 )
TEMPERATURE FACTOR ( Tab 10.3.4, NDS 2005, Page 58 )

THE ALLOWABLE LATERAL DESIGN VALUE FOR THE TOE-NAIL

0
10d
0

Common Wire Nail


Douglas Fir-Larch, G=0.5

1.6
1.0
1.0

157

lbf

ANALYSIS
TOE-NAIL FACTOR ( Sec 11.5.4.2, NDS 05, Page 78 )
NAIL LENGTH
THE SIDE MEMBER THICKNESS IS TAKEN TO BE EQUAL TO
THE PENETRATION OF THE NAIL INTO THE MAIN MEMBER
NAIL DIAMETER
THE PENETRATION FACTOR (Note 3, Tab 11N, NDS 2005, Page 97)

Ctn =
0.83
L =
in
3
ts = L / 3 =
1
p = L(cos30o) -ts =
D =
0.148 in
Cd =
1.00

in
1.60

in

THE NOMINAL DESIGN VALUE FOR SINGLE SHEAR IS TABULATED IN NDS 2005 TABLE 11N, PAGE 97, AS
Z =
118
lbf
THE ALLOWABLE LATERAL DESIGN VALUE FOR THE TOE-NAIL IS

Z' =

ZCDCMCtCdCtn

Typical Nail Dimensions (Appendix L4, NDS 2005, Page 167)


Penny-Weight
Type
6d
7d
8d
10d
12d
16d
20d
6

10
Length
Common Diameter
Head
Box

Sinker

2 1/4

2 1/2

10
3

12

16

3 1/4

3 1/2

20
4

157

30d

40d

50d

30

40

50

4 1/2

lbf

5 1/2

60d
60
6

0.113

0.113

0.131

0.148

0.148

0.162

0.192

0.207

0.225

0.244

0.263

0.266

0.266

0.281

0.312

0.312

0.344

0.406

0.438

0.469

0.500

0.531

Length

2 1/4

2 1/2

3 1/4

3 1/2

4 1/2

Diameter

0.099

0.099

0.113

0.128

0.128

0.135

0.148

0.148

0.162
0.406

Head

0.266

0.266

0.297

0.312

0.312

0.344

0.375

0.375

Length

1 7/8

8 1/8

2 3/8

2 7/8

3 1/8

3 1/4

3 3/4

4 1/4

4 3/4

5 3/4

Diameter

0.092

0.099

0.113

0.120

0.135

0.148

0.177

0.192

0.207

0.244

Head

0.234

0.250

0.266

0.281

0.312

0.344

0.375

0.406

0.438

0.500

Technical References:
1. "National Design Specification, NDS", 2005 Edition, AF&AP, AWC, 2005.
2. Alan Williams: "Structural Engineering Reference Manual", Professional Publications, Inc, 2001.

__
Page 261 of 533
524

PROJECT :
CLIENT :
JOB NO. :
DATE :
Connection Design for Wall & Diaphragm Based on IBC 09 / CBC 10

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA
GRAVITY LOAD

D+L =

250

plf

SERVICE ANCHORAGE FORCE

Fanch =

420

plf

V=

640

plf

SERVICE DIAPHRAGM SHEAR FORCE

LEDGER SPECIES ( 0=Douglas Fir-Larch, 1=Douglas Fir-Larch(N),


2=Hem-Fir(N), 3=Hem-Fir, 4=Spruce-Pine-Fir)
LEDGER GRADE

Douglas Fir-Larch, G=0.5

No.1

( 0=Select Structural, 1=No.1 & Btr, 2=No.1, 3=No.2,


4=No.3, 5=Stud, 6=Construction, 7=Standard, 8=Utility)
LEDGER SIZE

12

( No.1, Douglas Fir-Larch, G=0.5 )


I=
ANCHOR BOLT DIAMETER
3/4
in
WET SERVICE FACTOR ( Tab 10.3.3, NDS 2005, Page 58 ) C M =

1.0

TEMPERATURE FACTOR ( Tab 10.3.4, NDS 2005, Page 58 )Ct =

1.0

PURLIN ANCHORS SPACING

S=

36

in

CMU

TYPE OF MASONRY ( 1=CMU, 2=BRICK )


THICKNESS OF WALL

t=

CMU SPECIAL INSPECTION ( 0=NO, 1=YES )

in

Yes

MASONRY STRENGTH

fM' =

1.5

ksi

REBAR YIELD STRESS

fy =

60

ksi

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

Yes

WALL HORIZ. REINF.

16

in. o. c.

DESIGN SUMMARY
4 x 12 LEDGER with 3/4 in DIA. A.B.'s @ 24 in o.c.
SIMPSON PLURLIN ANCHOR PAI23 w/ 11-10d x 1 1/2 Nails @ 36 in o.c.

ANALYSIS
THE DIAPHRAGM SHEAR TRANSFERS INTO THE TOP OF THE LEDGER BY NAILS THOUGH PLY WOOD AND THE LEDGER BOLTS WOULD
RESIST BOTH THE DIAPHRAGM SHEAR BY PARALLEL TO GRAIN BEARING AND THE GRAVITY LOAD BY PERPENDICULAR TO GRAIN
BEARING. LATER FORCES IN THE OTHER DIRECTION WOULD BE RESIST BY SIMPSON PLURLIN ANCHORS.
CHECK LEDGER CAPACITY
LOAD DURATION FACTOR ( Tab 2.3.2, NDS 2005, Page 8 )

(C D)Lat =

1.6

(CD)D+L =

1.0

GROUP ACTION FACTOR (Sec 10.3.6, NDS 2005, Page 60)

Cg =

1.0

GEOMETRY FACTOR ( Sec 11.5.1, NDS 2005, Page 76 )

C' =

1.0

(for wind/seismic loads)


(for gravity loads)
( All dimensions conform to the specified minimums.)

DESIGN VALUE FOR THE BOLT BEARING PERPENDICULAR TO GRAIN (Tab 11E, NDS 2005, Page 85)

ZA =

880

DESIGN VALUE FOR THE BOLT BEARING PARALLEL TO GRAIN (Tab 11E, NDS 2005, Page 85)

Z __ =

1640

lbf
lbf

ZA' = ZA(CD)D+LCMCtCgC' =
THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING PERPENDICULAR TO GRAIN

880

lbf

THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING PARALLEL TO GRAIN

2624

lbf

THE ANGLE BETWEEN DIRECTION OF COMBINED LOAD AND DIRECTION OF GRAIN

Z__' = Z__(CD)LATCMCtCgC' =
T =

21.34

THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING AT THE ANGLE TO GRAIN ZT' = ZA'Z__' /(ZA'cos TZ||'sin2T) =

2079

THE MAXIMUM ALLOWABLE BOLT SPACING SHALL BE CALCULATED AS FOLLOWS :

'
Z
MIN A ,
D L

S1

2
2
D
L



V
'

ZT

36.30

in

( Use 24 in )

BASIC DESIGN VALUE FOR SHEAR (Tab 4A, NDS 2005 SUPP, Page 31)

Fv =

THE ALLOWABLE DESIGN VALUE FOR SHEAR

Fv' =

DEPTH FROM THE UNLOADED EDGE OF THE LEDGER TO THE CENTER OF THE BOLT de

180

psi

Fv(CD)D+LCMCt =

5.63

180

in

THE ALLOWABLE DESIGN SHEAR IS GIVEN BY NDS 2005 Eq. 3.4-6, Page 17, AS

'

2 '
de
F v b d e

3
d

591

lbf

>

(D+L)S

500

lbf

[Satisfactory]

psi

lbf

DESIGN PURLIN ANCHORS

cont'd

SELECT SIMPSON PAI23 w/ 11-10d x 1 1/2 Nails @ 36 in o.c.


DESIGN FORCE FOR STEEL ANCHOR
lbf

<

1880

lbf, allowable

DESIGN FORCE FOR WOOD MEMBER


FanchS = 1260 lbf

FanchS =

1260

<

1379

lbf, allowable

[Satisfactory]

CHECK WALL CAPACITY TO SPAN LATERALLY S SPACING


ALLOWABLE MASONRY STRESS FACTOR :
Allowable reinf. stress

SF

1.333

Fs

32000

psi

Modular ratio

Fb=(SF)(0.33fm ')

660

psi

Wall reinf. area

Em

1350

ksi

Steel elasticity modulus

Es

29000

Effective width

bw

12

Allowable stress

Masonry elasticity modulus

The tensile stress in reinforcement is

F anch S
8 A s jd

As

21.48
0.23

Tension reinf. ratio

0.005

ksi

The neutral axis depth factor

0.36

in

The lever-arm factor

0.88

The compressive stress in the extreme fiber is

6938

psi

<

Fs

[Satisfactory]

fb

F anch S
2
4b w jk d

185

psi

Technical References:
1. "National Design Specification, NDS", 2005 Edition, AF&AP, AWC, 2005.
2. Alan Williams: "Structural Engineering Reference Manual", Professional Publications, Inc, 2001.

<

Fb

[Satisfactory]

in / ft

PROJECT :
CLIENT :
JOB NO. :
DATE :
Connection Design for Wall & Diaphragm Based on IBC 09 / CBC 10

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA
GRAVITY LOAD

D+L =

250

plf

SERVICE ANCHORAGE FORCE

Fanch =

300

plf

V=

640

plf

SERVICE DIAPHRAGM SHEAR FORCE

LEDGER SPECIES ( 0=Southern Pine with 2"-4" Wide,


1=Southern Pine with 5"-6" Wide)

Southern Pine

LEDGER GRADE

Non-Dense Select Structural

( 0=Dense Select Structural, 1=Select Structural, 2=Non-Dense Select Structural, 3=No.1 Dense,
4=No.1, 5=No.1 Non-Dense, 6=No.2 Dense, 7=No.2, 8=No.2 Non-Dense)

LEDGER SIZE

12

( Non-Dense Select Structural, Southern Pine )


I=
ANCHOR BOLT DIAMETER
3/4
in
WET SERVICE FACTOR ( Tab 10.3.3, NDS 2005, Page 58 ) CM =

1.0

TEMPERATURE FACTOR ( Tab 10.3.4, NDS 2005, Page 58 )Ct =

1.0

PURLIN ANCHORS SPACING

S=

36
1

CMU

t=

in

Yes

TYPE OF MASONRY ( 1=CMU, 2=BRICK )


THICKNESS OF WALL
CMU SPECIAL INSPECTION ( 0=NO, 1=YES )

in

MASONRY STRENGTH

fM' =

1.5

ksi

REBAR YIELD STRESS

fy =

60

ksi

WALL HORIZ. REINF.

16

in. o. c.

Yes

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2)

DESIGN SUMMARY
4 x 12 LEDGER with 3/4 in DIA. A.B.'s @ 24 in o.c.
SIMPSON PLURLIN ANCHOR PAI18 w/ 8-10d x 1 1/2 Nails @ 36 in o.c.

ANALYSIS
THE DIAPHRAGM SHEAR TRANSFERS INTO THE TOP OF THE LEDGER BY NAILS THOUGH PLY WOOD AND THE LEDGER BOLTS WOULD
RESIST BOTH THE DIAPHRAGM SHEAR BY PARALLEL TO GRAIN BEARING AND THE GRAVITY LOAD BY PERPENDICULAR TO GRAIN
BEARING. LATER FORCES IN THE OTHER DIRECTION WOULD BE RESIST BY SIMPSON PLURLIN ANCHORS.
CHECK LEDGER CAPACITY
LOAD DURATION FACTOR ( Tab 2.3.2, NDS 2005, Page 8 )

(CD)Lat =

1.6

(CD)D+L =

1.0

GROUP ACTION FACTOR (Sec 10.3.6, NDS 2005, Page 60)

Cg =

1.0

GEOMETRY FACTOR ( Sec 11.5.1, NDS 2005, Page 76 )

C' =

1.0

(for wind/seismic loads)


(for gravity loads)
( All dimensions conform to the specified minimums.)

DESIGN VALUE FOR THE BOLT BEARING PERPENDICULAR TO GRAIN (Tab 11E, NDS 2005, Page 85)

ZA =

950

DESIGN VALUE FOR THE BOLT BEARING PARALLEL TO GRAIN (Tab 11E, NDS 2005, Page 85)

Z __ =

1680

lbf
lbf

ZA' = ZA(CD)D+LCMCtCgC' =
THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING PERPENDICULAR TO GRAIN

950

lbf

THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING PARALLEL TO GRAIN

Z__' = Z__(CD)LATCMCtCgC' =

2688

lbf

THE ANGLE BETWEEN DIRECTION OF COMBINED LOAD AND DIRECTION OF GRAIN

T =

21.34

THE ALLOWABLE DESIGN VALUE FOR THE BOLT BEARING AT THE ANGLE TO GRAIN ZT' = ZA'Z__' /(ZA'cos TZ||'sin2T) =

2164

lbf

THE MAXIMUM ALLOWABLE BOLT SPACING SHALL BE CALCULATED AS FOLLOWS :

'
Z
MIN A ,
D L

S1

2
2
D L  V
'

ZT

37.79

in

( Use 24 in )

BASIC DESIGN VALUE FOR SHEAR (Tab 4B, NDS 2005 SUPP, Page 37)

Fv =

THE ALLOWABLE DESIGN VALUE FOR SHEAR

Fv' =

DEPTH FROM THE UNLOADED EDGE OF THE LEDGER TO THE CENTER OF THE BOLTde

175

psi

Fv(CD)D+LCMCt =

5.63

175

psi

in

THE ALLOWABLE DESIGN SHEAR IS GIVEN BY NDS 2005 Eq. 3.4-6, Page 17, AS

2 '
de
F v b d e
3
d

500

lbf

[Satisfactory]

DESIGN FORCE FOR STEEL ANCHOR

FanchS =

900

lbf

<

1255

lbf, allowable

DESIGN FORCE FOR WOOD MEMBER

FanchS =

900

lbf

<
1004
[Satisfactory]

lbf, allowable

'

574

lbf

>

(D+L)S

DESIGN PURLIN ANCHORS


SELECT SIMPSON PAI18 w/ 8-10d x 1 1/2 Nails @ 36 in o.c.

CHECK WALL CAPACITY TO SPAN LATERALLY S SPACING


ALLOWABLE MASONRY STRESS FACTOR :
Allowable reinf. stress

SF

cont'd
=

1.333

Fs

32000

psi

Modular ratio

Fb=(SF)(0.33fm')

660

psi

Wall reinf. area

Em

1350

ksi

Steel elasticity modulus

Es

29000

Effective width

bw

12

Allowable stress

Masonry elasticity modulus

The tensile stress in reinforcement is

F anch S
8 A s jd

As

21.48
0.23

Tension reinf. ratio

0.005

ksi

The neutral axis depth factor

0.36

in

The lever-arm factor

0.88

The compressive stress in the extreme fiber is

4956

psi

<

Fs

[Satisfactory]

fb

F anch S
2
4b w jk d

132

psi

Technical References:
1. "National Design Specification, NDS", 2005 Edition, AF&AP, AWC, 2005.
2. Alan Williams: "Structural Engineering Reference Manual", Professional Publications, Inc, 2001.

<

Fb

[Satisfactory]

in / ft

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

DATE :

Drag / Collector Force Diagram Generator


INPUT DATA
TOTAL SHEAR FORCE (ASD)

Fp =

15.16

n=

NUMBER OF SEGMENTS

kips

Segment

Length, ft

17.5

22.67

13.83

35.5

10

Shear Wall ?

Yes

No

Yes

No

Yes

ANALYSIS
TOTAL DRAG LENGTH

Ldrag =

99.5

ft

TOTAL SHEAR WALL LENGTH

Lwall =

41.33

ft

vdiaphragm = Fp / vdrag =

152

plf

SHEAR WALL SHEAR STRESS

vshear wall = Fp / vwall =

367

plf

Drag Axial Force, kips

DIAPHRAGM SHEAR STRESS

Section Point

Distance, ft

17.5

40.17

54

89.5

99.5

Axial Force

3.75

0.30

3.26

-2.14

0.00

5
4
3
2
1
0
-1
-2
-3
Distance, ft
DRAG / COLLECTOR FORCE DIAGRAM

__

SHEAR WALL & DRAG ELEVATION

Page 266 of 533


524

PAGE :
DESIGN BY :
REVIEW BY :

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Wood Beam Design Based on NDS 2012


INPUT DATA & DESIGN SUMMARY
BEAM SECTION
LSL 1 3/4 x 14

BEAM SPAN

L1 =

12

CANTILEVER

L2 =

Timberstrand LSL 2.1E

ft
ft, (0 for no cantilever)
wDL,1 =

0.35

kips / ft

wDL,2 =

0.25

kips / ft

wLL,1 =

0.14

kips / ft

wLL,2 =

0.2

kips / ft

CONCENTRATED LOADS
Dead (kips)
Live (kips)
Location from Left End (ft)

P1
0.65
0.26
4

P2
0.6
0.4
8

4 : 12 ( =

18.43

SLOPED DEAD LOADS


PROJECTED LIVE LOADS

SLOPE

P3
1.2
1
15

DEFLECTION LIMIT OF LIVE LOAD


LL = L / 360
Code
1
2
3
4
5
6
Choice

Duration Factor, CD
Condition
0.90
Dead Load
1.00
Occupancy Live Load
1.15
Snow Load
1.25
Construction Load
1.60
Wind/Earthquake Load
2.00
Impact Load
=>
Construction Load
4

THE BEAM DESIGN IS ADEQUATE.

3
ANALYSIS
DETERMINE REACTIONS, MOMENTS & SHEARS
d
w DL ,1

L
+ w LL ,1 L1 + DL ,2 + w LL ,2 ( L1 + 0.5 L 2 ) 2 + P =
R 2 = 0.5
cos

cos

L1
L1

w DL ,1

+ w LL ,1 L1 + DL ,2 + w LL ,2 L 2 + P R 2 =
R1 =
cos

cos

M max =

9.1

ft-kips

V max =

6.95

kips, at R2 left.

3.27

8.34

kips

X1 =

4.80

ft

X2 =

5.20

ft

X3 =

2.00

ft

kips

w DL ,2

+ w LL ,2 L 22 + P 3 L 2 =
M Min = 0.5
cos

8.7

ft-kips

DETERMINE SECTION PROPERTIES AND DESIGN FACTORS


L u = Max(X 3 , L2 ) =
3.0
ft, (NDS 2012 Table 3.3.3)
LSL 1 3/4 x 14 Properties
b =

1.75

in

Fb =

d =

14.00

Fv =

A =

24.5

in
in2

E' =

3,451 psi
400

psi, (NDS 97 CH included)

2,100 ksi

lE =

6.2

ft, (Tab 3.3.3 footnote 1)

RB =

18.4

< 50

E'y =

2,100

ksi

(cont'd)
Sx =

57.2

in3

Fb' =

I =

400

in4

Fv' =

E = Ex =

2100

ksi

E'min =

CD
1.25

CM
1.00

Ct
1.00

Ci
1.00

CL
0.77

FbE =

3,302 psi
500

Fb* =

psi

CV
1.00

Cc
1.00

psi

4313.39 psi

F = FbE / Fb* =

1,085 ksi
CF
1.00

3841

0.89

Cr
1.00

CHECK BENDING AND SHEAR CAPACITIES


'

<
<

Cantilever:

f b ' = M Min / S x =

1823

psi

Middle Span:

f b = M Max / S x =

1911

psi

Shear:

425
psi
<
f v ' = 1.5 V Max / A =
(neglected d offset conservatively)

Fb =

3302

psi

[Satisfactory]

Fb =

4313

psi

[Satisfactory]

Fv'

[Satisfactory]

CHECK DEFLECTION AT LIVE LOAD CONDITION


L = L 1 / cos =
12.65
ft, beam sloped span

w 1 = w LL,1 cos

PLL2
4.22
0.38
0.13

w 2 = w LL,2 cos

0.18

a or b, (ft)
P , (k)

PLL1
8.43
0.25

PLL3
3.16
0.95
klf, perpendicular to beam
klf, perpendicular to beam

P 3a 32 ( L + a 3 ) w 2a 33 ( 4 L + 3a 3 )
+
End =
cos =
3EI
24 EI

<
Mid

0.06415 Pb 2 2
=
L b
EIL

1.5

4
+ 5w1L cos =
384 EI

<

0.13

in, downward to vertical direction.

2 L2 / 360
0.13

0.20

in

[Satisfactory]

in, downward to vertical direction.


L1 / 360

0.40

in

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Lag Screw Connection Design Based on NDS 2005


INPUT DATA & DESIGN SUMMARY
LOADS (ASD)

W=
3
lbs
F=
15
lbs
M=
14
ft-lbs
NUMBER OF LAG SCREWS
n=
4
=
LAG SCREW DIAMETER
1/4
in
1
in, (if one row input 0)
LAG SCREW SPACING
S1 =
S2 =
1
in
MAIN MEMBER
2
thk. x
4
width
SIDE MEMBER
2
thk. x
4
width
LOAD DURATION FACTOR ( Tab 2.3.2, NDS 2005, Page 8 )
CD =
WET SERVICE FACTOR ( Tab 10.3.3, NDS 2005, Page 58 )
CM =

1.6
1.0

Ct =

TEMPERATURE FACTOR ( Tab 10.3.4, NDS 2005, Page 58 )


GROUP ACTION FACTOR APPLY? ( 0 = No, 1 = Yes)

Yes, (

1.0
Cg =

0.997

, NDS 2005, 10.3.6)

THE CONNECTION, (4) - 0.25 Dia. x 3", IS ADEQUATE.

ANALYSIS
CHECK EDGE, END, & SPACING DISTANCE REQUIREMENTS (NDS 2005, Table 11.5.1A, Table 11.5.1B, & Table 11.5.1C)
Eg =

1.25

in

>

1.5 D

En =

1.25

in

>

3.5 D

[Satisfactory]

S=

in

>

3D

[Satisfactory]

[Satisfactory]

CHECK WOOD CAPACITY


63
F = [(FF + FMF)2 + (FW + FMW)2 ]0.5 =
4
lbs / screw
where FF =
FW =
1
lbs / screw
J=
(in2 Screw Area)
2
C = Min (C1 , C2 , C3) =
where

Cg =

where

0.714

C2 = (actual shear area) / (min shear area for full design value) =

1.000

C3 = (actual spacing) / (min spacing for full design value) = S / 4D =

1.000

1/4

n=

EmAm =
Cd = P / (8 D) =

T-E=

0.997

, (group action factor, NDS 2005, 10.3.6, page 60)

REA = Min [(EsAs/EmAm) , (EmAm/EsAs)] =


= 180000 D1.5 =

7350000 lbs, (Em fr Tab.10.3.6C)


1 1/2

, (penetration depth factor, NDS 2005, tab 11J, footnote 3, page 92)
in, (length of thread penetration in main member)

1
in, (NDS 2005 tab L2, page 166)
1 27/32 in, (NDS 2005 tab L2, page 166)
132

lbs / screw, side member allowable capacity (NDS 2005, 11.3.3, page 72)

Z// =

150

lbs / screw, (NDS 2005, tab 11J, page 92)

Zs =

120

lbs / screw, (NDS 2005, tab 11J, page 92)

46.94

, angle between F & grain for side member at corner screw

__

Z // Z m
=
Z m =
2
2
Z // sin + Z m cos
Z// =
Zm =
=

1.003

m = u - (u2 - 1)0.5 = 0.925

7350000 lbs, (Em fr Tab.10.3.6C)


0.672

1.000

22500

u = 1+ S/2 [1 / EmAm + 1 / EsAs] =

in

Z // Z s
=
2
2
Z // sin + Z s cos

where

1+ R EA
1 m

P = S + (T - E) - ts = 1 11/32
S=

where

m 1 m

2n

n 1+ R EA m n (1+m ) 1+m 2 n

tm =

Z s =

, (geometry factor, NDS 2005, 11.5.1, page 76)

C1 = (actual end distance) / (min end distance for full design value) = En / 7D =

EsAs =

where

0.714

lbs / screw, actual load at corner screw


FMF =
42
lbs / screw, at corner screw
FMW =
42
lbs / screw, at corner screw

150
120
43.06

Z = MIN( Z// , Z ) CD Cg Cd =

134

lbs / screw, main member allowable capacity (NDS 2005, 11.3.3, page 72)

lbs / screw, (NDS 2005, tab 11J, page 92)


lbs / screw, (NDS 2005, tab 11J, page 92)
o

, angle between F & grain for main member at corner screw


63
>

lbs / corner screw, connection allowable capacity


F=

63

lbs / screw

Page 269 of 533


524

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wood Truss Design Based on NDS 2005


INPUT DATA & DESIGN SUMMARY

CONTINUED TOP CHORD (from 0 to 6 & from 6 to 11)

GLB 5 1/8 x 15

SLOPED DEAD LOADS

DL =

400

lbs / ft

CONTINUED BOTTOM CHORD (from 0 to 11)

GLB 5 1/8 x 10 1/2

PROJECTED LIVE LOADS

LL =

320

lbs / ft

ALL WEB MEMBER SIZE

6x6

SPECIE & GRADE

TRUSS SPAN LENGTH

L=

60

ft

TRUSS DEPTH

H=

10

ft

No. 1, Douglas Fir-Larch

THE TRUSS DESIGN IS ADEQUATE.

ANALYSIS
DESIGN CRITERIA
1. The intermediate finite element analysis include shear deformations using G equal to 0.5 E / (1+0.3).
2. There are different rotations at same joint of web to chord, since web pinned to continued chord.
3. The top chord factors, CP & CL , are based on two joints length. Other member factors, including CV, are based on their physical length.
DETERMINE JOINT DEFLECTIONS BY FINITE ELEMENT ANALYSIS

Joint

DL Deflection (in, deg)


(cont.) (pin-1)

(pin-2)

LL Deflection (in, deg)


(cont.) (pin-1)

(pin-2)

-0.2914

-0.2211

-0.0690

-0.4614

-0.0523

-0.3502

-0.2602
-0.1391

-0.1237

-0.1975
-0.1056

-0.0939

0.0174

-0.4618

-0.1234

-0.1237

-0.0548

0.0132

-0.3505

-0.0937

-0.0939

-0.0416

-0.0319

-0.5729

-0.0039

-0.0548

-0.0426

-0.0242

-0.4348

-0.0029

-0.0416

-0.0323

0.0276

-0.5703

-0.0086

-0.0426

-0.0054

0.0209

-0.4328

-0.0065

-0.0323

-0.0041

-0.5682

-0.0054

0.0054

-0.4312

5.56E-17

-0.0041

0.0041

-0.5457

0.0561

-0.0561

-0.4141

0.0426

-0.0426

0.0319

-0.5729

0.0039

0.0548

0.0426

0.0242

-0.4348

0.0029

0.0416

0.0323

-0.0276

-0.5703

0.0086

0.0426

0.0054

-0.0209

-0.4328

0.0065

0.0323

0.0041

0.0690

-0.4614

0.1391

0.1237

0.0523

-0.3502

0.1056

0.0939

10

-0.0174

-0.4618

0.1234

0.1237

0.0548

-0.0132

-0.3505

0.0937

0.0939

0.0416

11

0.2602

0.2914

0.1975

0.2211

CHECK MAXIMUM LIVE LOAD DEFLECTION


DLL =

0.43

in

<

L / 240

3.00

in

[Satisfactory]

DETERMINE REQUIRED CAMBER AT 1.5 TIMES MAXIMUM DEAD LOAD DEFLECTION


1.5 DDL =

0.86

in

DETERMINE MEMBER FORCES UNDER LOAD COMBINATION (DL + LL)


Joints

__

I end section

J end section

Member

I-J

N (kips)

V (kips)

M(ft-kips)

N (kips)

V (kips)

0-1

-52.665

0.460

0.000

52.665

-0.460

M(ft-kips)
4.595

0-2

56.853

4.017

0.000

-54.508

3.019

5.264

1-2

0.865

0.000

0.000

-0.865

0.000

0.000

1-3

-52.665

-0.406

-4.595

52.665

0.406

0.537

REACTIONS:

2-3

7.813

0.000

0.000

-7.813

0.000

0.000

R0 = R11 =

2-4

48.531

2.490

-5.264

-46.186

4.546

-5.570

3-4

-2.784

0.000

0.000

2.784

0.000

0.000

Page 270 of 533


524

22.25

kips, upward

3-5

-45.253

-0.093

-0.537

45.253

0.093

-0.390

4-5

14.231

0.000

0.000

-14.231

0.000

0.000

10

4-6

36.569

4.046

5.570

-34.224

2.989

0.000

11

5-6

-15.973

0.000

0.000

15.973

0.000

0.000

12

5-7

-45.253

0.093

0.390

45.253

-0.093

0.537

13

5-8

14.231

0.000

0.000

-14.231

0.000

0.000

14

6-8

34.224

2.989

0.000

-36.569

4.046

-5.570

15

7-8

-2.784

0.000

0.000

2.784

0.000

0.000

16

7-9

-52.665

0.406

-0.537

52.665

-0.406

4.595

17

7 - 10

7.813

0.000

0.000

-7.813

0.000

0.000

18

8 - 10

46.186

4.546

5.570

-48.531

2.490

5.264

19

9 - 10

0.865

0.000

0.000

-0.865

0.000

0.000

20

9 - 11

-52.665

-0.460

-4.595

52.665

0.460

0.000

21

10 - 11

54.508

3.019

-5.264

-56.853

4.017

0.000

(cont'd)

CHECK WOOD MEMBERS CAPACITIES

Member
Top Chord

Max. Section Force

CD

CF

CP

CL

CV

1.25

1.00

0.51

0.97

0.94

N (kips)

V (kips)

M(ft-kips)

fb

F'b

fc

F'c

fv

F'v

-56.853

4.546

5.570

348

2816

740

1015

89

331

[Satisfactory]

Member
Bot Chord

Max. Section Force

CD

CF

CL

CV

1.25

1.00

1.00

0.91

N (kips)

V (kips)

M(ft-kips)

fb

F'b

ft

F't

fv

F'v

52.665

0.460

4.595

586

2737

979

1375

13

331

[Satisfactory]

Compression

Max. Section Force

Web Member

N (kips)

9 & 13

-14.231

V (kips)

M(ft-kips)

CD

CF

CP

1.25

1.00

0.50

fc

F'c

470

578
[Satisfactory]

__
Page 271 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Tables for Wood Post Design Based on NDS 2005


DURATION FACTOR (1.0, 1.15, 1.25, 1.6)
COMMERCIAL GRADE (# 1 or # 2)

CD =
#

1.00
1

, (NDS 2.3.2)

Post Axial Capacity for Douglas Fir-Larch # 1, (kips)


Height
(ft)
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

4x4
11.78
9.35
7.48
6.07
5.00
4.18
3.55
3.04
2.63
2.30
2.03
1.80
1.61
1.45
1.31
1.19
1.09
0.99
0.91
0.84
0.78
0.72
0.67
0.63
0.59

4x6
18.25
14.57
11.68
9.49
7.83
6.56
5.56
4.77
4.13
3.62
3.19
2.83
2.53
2.28
2.06
1.87
1.70
1.56
1.44
1.32
1.22
1.14
1.06
0.99
0.92

4x8
23.68
19.01
15.29
12.45
10.29
8.62
7.31
6.28
5.44
4.76
4.20
3.73
3.33
3.00
2.71
2.46
2.25
2.06
1.89
1.74
1.61
1.50
1.39
1.30
1.21

4 x 10
29.67
23.97
19.36

4 x 12
36.09
29.15
23.55

Section Size
6x6
27.56
26.34
24.80

6x8
37.59
35.92
33.81

6.07
5.35
4.75
4.25
3.82
3.46
3.14
2.86
2.62
2.41
2.22
2.06
1.91
1.78
1.66
1.55

7.38
6.51
5.78
5.17
4.65
4.20
3.82
3.48
3.19
2.93
2.71
2.50
2.32
2.16
2.02
1.88

11.92
10.67
9.59
8.66
7.84
7.13
6.51
5.97
5.48
5.06
4.68
4.34
4.03
3.76
3.51
3.29

Section Size
6x6
23.08
22.24
21.17
19.88
18.40
16.81
15.21
13.68
12.28
11.02
9.92
8.94
8.09
7.35
6.69
6.12
5.61
5.16
4.76
4.41
4.09
3.80
3.55
3.31
3.10

16.25
14.55
13.08
11.80
10.70
9.73
8.88
8.14
7.48
6.90
6.38
5.91
5.50
5.12
4.79
4.48

6 x 10
47.61
45.50
42.83
39.65
36.13
32.52
29.06
25.88
23.06
20.58
18.43
16.57
14.95
13.55
12.32
11.25
10.31
9.47
8.73
8.08
7.49
6.96
6.49
6.06
5.68

6 x 12
57.64
55.07
51.84
48.00
43.74
39.37
35.18
31.33
27.91
24.92
22.31
20.06
18.10
16.40
14.92
13.62
12.48
11.47
10.57
9.78
9.07
8.43
7.86
7.34
6.87

8x8
53.81
52.79
51.52
49.96
48.09
45.89
43.41
40.69
37.86
35.01
32.25
29.64
27.23
25.01
23.01
21.19
19.56
18.09
16.76
15.57
14.49
13.52
12.63
11.83
11.09

8 x 10
68.16
66.87
65.26
63.28
60.91
58.13
54.98
51.55
47.96
44.35
40.85
37.55
34.49
31.68
29.14
26.84
24.77
22.91
21.23
19.72
18.36
17.12
16.00
14.98
14.05

6x8
31.47
30.33
28.87
27.11
25.09
22.92
20.74
18.65
16.74
15.03
13.52
12.19
11.03
10.02
9.13
8.34
7.65
7.04
6.50
6.01
5.58
5.19
4.84
4.52
4.23

6 x 10
39.86
38.41
36.57
34.34
31.78
29.03
26.27
23.63
21.21
19.04
17.13
15.45
13.97
12.69
11.56
10.57
9.69
8.92
8.23
7.61
7.06
6.57
6.13
5.73
5.36

6 x 12
48.25
46.50
44.27
41.57
38.47
35.14
31.80
28.60
25.67
23.05
20.73
18.70
16.92
15.36
13.99
12.79
11.73
10.79
9.96
9.22
8.55
7.95
7.42
6.93
6.49

8x8
44.68
43.97
43.09
42.02
40.74
39.23
37.48
35.54
33.44
31.26
29.06
26.93
24.90
23.00
21.25
19.64
18.18
16.86
15.65
14.56
13.57
12.67
11.86
11.11
10.43

8 x 10
56.59
55.70
54.59
53.23
51.61
49.69
47.48
45.02
42.36
39.59
36.81
34.11
31.54
29.13
26.91
24.88
23.03
21.35
19.83
18.45
17.19
16.05
15.02
14.08
13.21

Post Axial Capacity for Southern Pine # 1, (kips)


Height
(ft)
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Note:
1.
2.

4x4
12.03
9.48
7.55
6.11
5.02
4.20
3.56
3.05
2.64
2.31
2.03
1.81
1.61
1.45
1.31
1.19
1.09
0.99
0.91
0.84
0.78
0.72
0.67
0.63
0.59

4x6
18.60
14.74
11.77
9.55
7.87
6.58
5.57
4.78
4.14
3.62
3.19
2.84
2.53
2.28
2.06
1.87
1.71
1.56
1.44
1.32
1.23
1.14
1.06
0.99
0.92

4x8
24.06
19.20
15.40
12.51
10.33
8.64
7.33
6.29
5.45
4.77
4.20
3.73
3.34
3.00
2.71
2.46
2.25
2.06
1.89
1.75
1.61
1.50
1.39
1.30
1.22

4 x 10
30.38
24.33
19.56
15.92
13.14
11.01
9.34
8.01
6.95
6.08
5.36
4.76
4.26
3.83
3.46
3.14
2.87
2.63
2.41
2.23
2.06
1.91
1.78
1.66
1.55

4 x 12
36.94
29.59
23.79
19.36
15.98
13.39
11.36
9.74
8.45
7.39
6.52
5.79
5.18
4.65
4.21
3.82
3.49
3.19
2.94
2.71
2.50
2.32
2.16
2.02
1.89

__

The bold values require steel bearing plate based on, Fc, 625 psi.

The table values are from Wood Column software at www.Engineering-International.com .

Page 272 of 533


524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Tables for Wood Beam Design Based on NDS 2005


DURATION FACTOR (0.9, 1.0, 1.15, 1.25)
COMMERCIAL GRADE (# 1 or # 2)
DEFLECTION LIMITATION

CD =
#

1.15
1

, (NDS 2.3.2)

= L / 240

Beam Allowable Uniform Load for Douglas Fir-Larch # 1, (plf)


Span
(ft)
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

2x6
209
154
118
93
75
59
45
36
29
23
19
16
13
11
10
8
7
6
6
5
4
4
4
3
3

2x8
336
247
189
149
121
100
84
72
62
53
44
37
31
26
22
19
17
15
13
12
10
9
8
7
7

2 x 10
501
368
282
223
180
149
125
107
92
80
70
62
56
50
45
40
35
31
27
24
21
19
17
15
14

2 x 12
674
495
379
299
243
200
168

4x6
489
359
275
217
176
138
106

4x8
849
624
477
377
306
253
212

67
61
55
50
46
42
39
36
33
31
28
25

27
23
20
17
15
13
12
10
9
8
8
7

61
52
45
39
35
30
27
24
21
19
17
16

Section Size
4 x 10
4 x 12
1276
1729
937
1271
717
973
567
769
459
623
379
515
319
432
272
368
234
318
204
277
179
243
159
215
142
192
127
172
109
156
94
141
82
129
72
118
63
108
56
100
50
89
44
80
40
71
36
64
32
58

6x8
1482
1089
834
659
534
441
371
313
251
204
168
140
118
100
86
74
65
57
50
44
39
35
31
28
25

6 x 10
2378
1747
1338
1057
856
708
595
507
437
381
334
284
240
204
175
151
131
115
101
89
79
71
64
57
52

6 x 12
3485
2561
1961
1549
1255
1037
871
742
640
558
490
434
387
348
310
268
233
204
179
159
141
126
113
102
92

Section Size
4 x 10
1520
1117
855
676
547
452
380
324
279
243
213

4 x 12
2162
1588
1216
961
778
643
540
461
397
346
304

6x8
1812
1331
1019
805
652
539
423
332
266
216
178

6 x 10
2907
2136
1635
1292
1047
865
727
619
534
440
362

63
56
50
44
40
36
32

113
100
89
80
71
64
58

53
47
42
37
33
30
27

107
95
84
75
68
61
55

6 x 12
4260
3130
2396
1893
1534
1267
1065
907
782
682
599
531
452
384
329
284
247
216
190
169
150
134
120
108
98

GLB

5 1/8 x 15

9823
7217
5525
4366
3536
2923
2456
2092
1804
1572
1381
1174
989
841
721
623
541
474
417
369
328
293
263
236
214

GLB

5 1/8 x 18

14145
10392
7957
6287
5092
4208
3536
3013
2598
2248
1963
1728
1533
1368
1228
1076
936
819
721
638
567
506
454
409
369

Beam Allowable Uniform Load for Southern Pine # 1, (plf)


Span
(ft)
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Note:
1.
2.
3.
4

2x6
266
195
149
108
79
59
45
36
29
23
19
16
13
11
10
8
7
6
6
5
4
4
4
3
3

2x8
420
308
236
187
151
125
104
82
66
53
44
37
31
26
22
19
17
15
13
12
10
9
8
7
7

2 x 10
592
435
333
263
213
176
148
126
109
95
83
74
64
54
47
40
35
31
27
24
21
19
17
15
14

2 x 12
842
619
474
374
303
251
211
179
155
135
118
105
94
84
76
69
63
55
49
43
38
34
31
28
25

4x6
620
456
349
251
183
138
106
83
67
54
45
37
31
27
23
20
17
15
13
12
10
9
8
8
7

4x8
1077
792
606
479
388
315
243
191
153
124
103
85
72
61
52
45
39
35
30
27
24
21
19
17
16

__

The bold values are deflection controlled.


Glulam 24F-1.8E used.
The beam continuously lateral supported by top diaphragm. (CL = 1.0)
The table values are from Wood Beam software at www.Engineering-International.com .

Page 273 of 533


524

GLB

5 1/8 x 15

9823
7217
5525
4366
3536
2923
2456
2092
1804
1572
1381
1174
989
841
721
623
541
474
417
369
328
293
263
236
214

GLB

5 1/8 x 18

14145
10392
7957
6287
5092
4208
3536
3013
2598
2255
1976
1745
1552
1389
1245
1076
936
819
721
638
567
506
454
409
369

PAGE :
DESIGN BY :
REVIEW BY :
Frame (not shown) by MFR
where Occurs

PROJECT :
CLIENT :
JOB NO. :
DATE :
Equipment Anchorage to Wood Roof Based on NDS 05 / IBC 09 / CBC 10

Long

=
=

1/2
4

in, NDS APP. L


in, NDS APP. L

W
H

=
=

1.4
8.25

kips
ft, 2/3 total height

EQUIPMENT WEIGHT
CM HEIGHT
ANCHORAGE LENGTH
LAG SCREWS ALONG L EDGE

L
=
NL
=
SL = L / (NL - 1) =

LAG SCREW SPACING

ANCHORAGE WIDTH
LAG SCREWS ALONG B EDGE

B
=
NB
=
SB = B / (NB - 1) =

LAG SCREW SPACING

8
3
48

ft
per line
in

8
2
96

ft
per line
in

INPUT DATA & DESIGN SUMMARY


LAG SCREW DIAMETER
LAG SCREW LENGTH

No. Bolts per Input

[THE ANCHORAGE, USING 1/2" x 4" LAG SCREWS, IS ADEQUATE.]


B

ANALYSIS
ALLOWABLE TENSION & SHEAR VALUES
ZII' = CD Cd Cg ZII =

252

lbs

1.6

(NDS Tab 2.3.2)

CD =

where

Cd = p / (8D) =

0.814

p = S + (T-E) - (Diaphragm Thk) - ts =


S + (T-E) =

3.688
0.298

Diaphragm Thk =
ts =
Cg =
ZII =
Z ' = CD Cd Cg Z =
Z =

0.134

in (10 gage, NDS Tab 11K)

0.92

(NDS 10.3.6)

210

lbs (NDS Tab 11K)

168

lbs

140

lbs (NDS Tab 11K)

(W ' p) = CD W (T-E) =
where W =
378
(T-E) =
2.188

3.256 in

in (NDS Appendix L2)


in (0.298 for 15/32, 0.319 for 19/32, UBC Table 23-2-H, page 3-420)

1323 lbs
lbs / in (NDS Tab 11.2A)
in (NDS Appendix L2)

DESIGN LOADS
FH = Fp = (KH) MAX{ 0.3SDSIpW , MIN[ 0.4apSDSIp(1+2z/h)/Rp W , 1.6SDSIpW ] } , (ASCE 7-05, Sec. 13.3.1)
= 1.3 MAX{ 0.24W , MIN[ 0.65W , 1.30W ]}
=

0.84 W , (SD)

0.60 W , (ASD)

FV = KV W =

0.10 W , (ASD)

0.84

0.14

where

kips

kips, up & down

SDS =

0.54

(ASCE 7-05 Sec 11.4.4)

Ip =

1.5

(ASCE Sec. 13.1.3)

ap =

(ASCE Tab. 13.6-1)

Rp =

1.5

(ASCE Tab. 13.6-1)

z=

h=

36
1.3
0.10

KH =
KV = KH 0.2 SDS / 1.4 =
MAXIMUM OVERTURNING MOMENT AT ANCHOR EDGE
MOT = Fp H =
6.95
ft-kips
4.48
ft-kips
MRES,L = (0.9W - Fv ) (0.5L) =
MRES,B = (0.9W - Fv ) (0.5B) = 4.48
ft-kips

<
<

MOT
MOT

ft
ft
(ASCE Sec. 13.4.2a)
(vertical seismic factor)

,therefore design tension anchors.


,therefore design tension anchors.

TENSION LOAD AT CORNER LAG SCREW


TL = (FV -0.9 W) / A + MOT y / I =
where

248

A = 2(NL + NB) -4 =
I = Xi =
2

9216

y = 0.5 L =

48

TB = (FV -0.9 W) / A + MOT y / I =

lbs / bolt
(total bolts)

where

in -bolts

13824

y = 0.5 B =

48

103
2

in -bolts
in

in

__

SHEAR LOAD AT EACH LAG SCREW


140
V = FH / A =

I = Yi =

lbs / bolt

CHECK CORNER SCREW CAPACITY AT COMBINED LATERAL AND WITHDRAWAL LOADS


2
2
Z ' = ZII'(W' p) / (ZII'sin + W'p cos )

650

lbs / bolt

-1
60.46
where
= tan (TL / V) =
2
2
Z ' = Z '(W' p) / (Z 'sin + W'p cos )

=
where

241

lbs / bolt

= tan (TB / V) =
-1

(NDS 11.4-1)

[TL2 + V2 ]0.5 =

>

lbs / bolt

[SATISFACTORY]

174

lbs / bolt

[SATISFACTORY]

(NDS 11.4-1)

[TB2 + V2 ]0.5 =

>

36.26

285

Page 274 of 533


524

lbs / bolt

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wood Diaphragm Design for a Discontinuity of Type 4 out-of-plane offset irregularity


INPUT DATA
OFFSET LATERAL SYSTEM DIMENSION
MAX TWO PERPENDICULAR LATERAL SYSTEM SPAN

B=
L=

12
32

ft
ft

PANEL GRADE ( 0 or 1)
=
1
<= Sheathing and Single-Floor
MINIMUM NOMINAL FRAMING WITH ( 2 or 3) =
3
in
MINIMUM NOMINAL PANEL THICKNESS =
15/32 in
COMMON NAIL SIZE ( 0=6d, 1=8d, 2=10d )
1
8d
SPECIFIC GRAVITY OF FRAMING MEMBERS
0.43
FRAMING OF Douglas-Fir-Larch OR Southern Pine ?
Yes
`
ALLOWABLE SHEAR FORCE ON TRANSFER DIAPHRAGM SIDE
MAX. ALLOWABLE COLLECTOR (DRAG) FORCE
MAX. ALLOWABLE CHORD FORCE

V =

10

kips

T drag =

11

kips

T chord =

kips

THE TRANSFER DIAPHRAGM DESIGN IS ADEQUATE.


BLOCKED 15/32 SHEATHING WITH 8d COMMON NAILS
@ 2.5 in O.C. BOUNDARY / 4 in O.C. EDGES / 12"O.C. FIELD.
(USE 2-CMST12 COLLECTOR/CHORD SIMPSON STRAP AROUND THE DIAPHRAGM.)

ANALYSIS
CHECK MAX DIAPHRAGM DIMENSION RATIO (SDPWS-08, 4.2.4 & IBC 09, 2308.12.6)
L/B=
2.67
>
2.00

<
4.00
[Satisfactory]
CHECK DIAPHRAGM SHEAR CAPACITY (ACI 318-08, 21.11.9)
v = 1.25 V / L =
508
plf, ASD, (ASCE 7-05, 12.3.3.4 & Table 12.3-2.4)
where
=
1.3
(ASCE 7-05, 12.10.1.1 & 12.3.4.2)
[Satisfactory]
THE SHEAR CAPACITIES PER IBC Table 2306.2.1 / SDPWS-08 Table 4.2A with ASD reduction factor 2.0 :
Blocked Nail Spacing
Min.
Min.
Member
Panel Grade
Sheathing and Single-Floor

Thickness
Common Penetration

Unblocked

Boundary / Other Edges

Width

Nail

(in)

(in)

(in)

6/6

4/6

2.5 / 4

2/3

Case 1

Others

8d

1 1/2

15/32

300

400

600

675

265

200

Note: The indicated shear numbers have reduced by specific gravity factor per SDPWS-08 Table 4.2A note 2.

CHECK DIAPHRAGM IN-PLANE FLEXURAL CAPACITY


M = 1.25 V B =
195.0
ft-kips, the max value same at both B & L sections, (ASCE 7-05, 12.3.3.4 & Table 12.3-2.4)
T max = M / MIN( L , B) =

16.3

kips

(THE 2-CMST12 SIMPSON STRAP REQUIRED.)


[Satisfactory]

CHECK COLLECTOR / CHORD STRAP CAPACITY


T = MAX( 1.25 T chord , 1.25 T drag) =
17.9
(THE 2-CMST12 SIMPSON STRAP REQUIRED.)

kips, (ASCE 7-05, 12.3.4, 12.10.1.1 & 12.10.2.1 Exception)


[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE:
Composite Strong Wall Design Based on ACI 318-08, AISI S100-2007 & ER-4943P

PAGE :
DESIGN BY :
REVIEW BY :

DESIGN CRITERIA
1.
At middle of wall, with out of plan loads (seismic or wind), the inside web of C-Stud within concrete and End Bar are used
as tension steel, conservatively.
2.
The bottom joint, which shall be clean & rough, is pinned connection out of plan (Mu,y zero), so only Holdown as shear
wall tension steel used.
3.
The Holdown / End Bar shall have full tension capacity with L d , L dh , & L s (ACI 318-08 12 & App. D). The two End Bars
shall be tied by horizontal strap (not shown), in the wall middle, at 4'-0" o.c. max.
4.
The wall, with high stiffness (small drift), can be partially used as shear wall to reach flexible diaphragm condition
(ASCE 7-10 Figure 12.3-1).
5.
The wall has higher fire-resistance ratings (2010 CBC Table 706.4) and capacity, than pure wood / metal wall, without
Type V construction limits.

INPUT DATA & DESIGN SUMMARY


C-STUD SECTION & SPACING

600S162-54

WALL LENGTH

Lw =

18
in o.c
( 50 ksi )

THE DESIGN IS ADEQUATE.

ft

FACTORED SAME HORIZONTAL SECTION LOADS


(SD Level, equal to 1.5 ASD Level Force)

Pu =

120

kips, axial

Mu,x =

150

ft-k, shear wall bending

Mu,y =

50

ft-k, out of plan bending

Vu,x =

17

kips, max horizontal shear load

3
ksi
fc ' =
Diameter = 0.875 in, with
Fy =
60
ksi
(Total SD level tension capacity at each end, 36.08 kips, # 7 Reinforcement)

CONCRETE STRENGTH
HOLDOWN / END BAR

ANALYSIS
C-STUD SECTION PROPERTIES OF EACH METAL STUD (SSMA page 7 & 8)
Fy =

t = 0.0566 in

50

ksi

h =

in

CHECK FLEXURAL & AXIAL CAPACITY

o =

2 0.85 f

'
C

, E c = 57

Ec
0.85 f

'
C

0.85 f

'
C

sE s ,
f y ,

c
c

o
o

f
2

for c o
for s t

for s > t

, E s = 29000ksi

'
C

for 0 < c < o

(cont'd)
339.10 kips
Pmax =0.8 [ 0.85 fc' (Ag - Ast) + fy Ast] =
(at max axial load, ACI 318-08 10.3.6.2)

400
350

where

300
250
200

Pn (k)

150
100

>
=

Pu
0.65

Ag =

216

[Satisfactory]
(ACI 318-08 9.3.2.2)
in2

Ast,C =

0.68

in2, C-Stud

Ast,H =

1.20

in2, Holdown / End Bar

50
0
-50 0

=0.65 + ( t - 0.002 ) (250 / 3) =


50

100

150

200

250

300

where

-100
-150

Mn (ft-k)

Mn =

206

ft-kips @ Pu =

120

max

0.025

min

0.0015 (ACI 318-08 14.2)

kips

D=
Cover =
d=

36.0
2.0
32.8
0.003

t =
C=

0.0021
19.4 in, at balanced condition

>

Mu =

158

>

provd

0.003

,bending one End Bar

<
provd
[Satisfactory]

0.009

,total steel

(ACI 318-08 21.5.2.1)

17.75 kips
, (ACI 318-08 9.3.2.3)

DETERMINE SHEAR WALL STORY DRIFT

u =

M u,x H 2 V u,x H 3
+
=
3 E cI x
E cI x

where

Ec =
Ix =
H=

1.07

in, SD level

3122 ksi
4
23328 in
14
ft, Story Height

>

in
in, (ACI 318-08 7.7.1)
in

c =

CHECK SHEAR CAPACITY (ACI 318-08 11.1 & 11.2)


Vn,x = [2 (fc')0.5Ag] =
=
where
0.75

0.656
(ACI 318-08 Fig. R9.3.2)

Vu,x

[Satisfactory]

ft-kips

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wood Pole or Pile Design Based on NDS 2012


INPUT DATA & DESIGN SUMMARY
ROUND TIMBER SPECIES
Southern Pine (Grouped)
Fb
1950

Fv
160

LENGTH
DIAMETER

Fc
1250

E
1500000

Emin
(psi, NDS Supplement Table 6)
600000

L =
D butt =

50
16

ft, (ASTM D25 or D3200)


in, (ASTM D25 or D3200)

D tip =

in, (ASTM D25 or D3200)

AXIAL COMPRESSION FORCE


P=
M =
CRITICAL/MAXIMUM BENDING MOMENT
The Moment Location from Tip End =
2
4
3
D, (in)
A, (in )
I, (in )
S, (in )
14.4
162.9
2110.7
293.1

20
17
40

kips, ASD
ft-kips, ASD
ft, (input 0, at tip end, for conservative)

CRITICAL/MAXIMUM SECTION SHEAR FORCE


V=
The Section Location from Tip End =
2
D, (in)
A, (in )
8.0
50.3

8
0

kips, ASD
ft, (input 0, at tip end, for conservative)

THE POLE/PILE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMPRESSION CAPACITY (NDS Table 6.3.1)
193
F c ' = F c C D C t C ct C p C es C ls =
CD
0.90

Where

Ct
1.0

psi

>

fc = P / A =

C ct
1.00

Cp
0.14

(Tab. 2.3.2) (Tab. 2.3.3) (Tab. 6.3.5)

Le

1383
1.2

= Ke L =

= 0.822 E' min / (L e /D) 2

Fc E

,(NDS 3.7.1)
720

L=

197

3253

>
Where

CD
1.60

Ct
1.0

[Satisfactory]

psi
in`
psi

E'min =
600000 psi, (NDS Table 6.3.1)
F = FcE / Fc* =
0.143
c =
0.85
Le / D =
50.0
<
50
, (NDS 3.7.1.4)
CHECK BENDING CAPACITY (NDS Table 6.3.1)
F b ' = F b C D C t C ct C F C ls =

psi

C ls
1.06

(Eq. 6.3-1) (Tab. 6.3.5)

C P = (1+F) / 2c - [((1+F) / 2c) 2 - F / c] 0.5


Fc * = Fc ' / Cp =

123
C es
1.16

psi
696

fb = M / S =
CF
0.99

C ct
1.00

[Satisfactory]

psi

[Satisfactory]

C ls
1.05

(Tab. 2.3.2) (Tab. 2.3.3) (Tab. 6.3.5) (NDS 6.3.7) (Tab. 6.3.5)

CHECK BENDING & COMPRESSION CAPACITY (NDS 3.9.2)


2

fb
fc
1
' +
F ' =
1

f
F
Fc
cE
c

b
f

c
'
F cE

f b
+

'
F bE

Where

<

<

1.0

0.67

7.07

= 1.20 E' min / R B 2

CHECK SHEAR CAPACITY (NDS Table 6.3.1)


256
F v ' = F v C D C t C ct =

[Satisfactory]

CD
1.60

Ct
1.0

[Satisfactory]

, (NDS 3.3.3.6)
14400

psi, (NDS 3.9.2)

psi

>
Where

1.0

R B = (L e / D) 0.5 =
FbE

0.97

C ct
1.00

(Tab. 2.3.2) (Tab. 2.3.3) (Tab. 6.3.5)

f v = 4 V / (3 A) =

212

psi

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wood Member (Beam, Column, Brace, Truss Web & Chord) Design Based on NDS 2012
INPUT DATA & DESIGN SUMMARY
SPECIES & GRADE
Glulam 24F-1.8E
L =
15
ft
LENGTH
SECTION SIZE
GLB 3 1/8 x 6
AXIAL COMPRESSION FORCE

THE MEMBER DESIGN IS ADEQUATE.


P=

10

kips, ASD

STRONG AXIS EFFECTIVE LENGTH

ke Lx =

15

ft, (NDS Table G1/Figure 3F)

WEAK AXIS EFFECTIVE LENGTH

ke Ly =

7.5

ft, (NDS Table G1)

Mx =

0.4

ft-kips, ASD

STRONG AXIS BENDING MOMENT


STRONG AXIS BENDING UNBRACED LENGTH

Le =

ft, (NDS Table 3.3.3)

0.1
ft-kips, ASD
V=
2.5
kips, ASD

WEAK AXIS BENDING MOMENT


My =
CRITICAL/MAXIMUM SECTION SHEAR FORCE

`
ANALYSIS
DETERMINE DESIGN VALUES (NDS Supplement Tables or ICC ESR)
Fb
2,400

psi ==>

Fv
265

Fc
1600

Ex,min
930000

b, (in)

Ey,min
830000

d, (in)
6.0

3.1

A, (in2)
18.8

Ix, (in4)
56.3

Sx, (in3)
18.8

Iy, (in4)
15.3

CHECK COMPRESSION CAPACITY (NDS Table 4.3.1 & Table 5.3.1)


763
psi
Fc ' = Fc CD CM Ct C F Ci Cp =
CD
0.90

Where

CM
1.00

>

fc = P / A =

Ct
1.0

CF
1.00

533
Ci
1.0

psi

(Tab. 2.3.2) (4.4.3/5.5.3) (Tab. 2.3.3) (NDS 4.3.6) (NDS 4.3.8)


2

C P = (1+F) / 2c - [((1+F) / 2c) - F / c]


1440

Fc * = Fc ' / Cp =

0.5

(NDS 4.4.2 for Truss only)

,(NDS 3.7.1)

psi
30

L e / d = Max( k e L x / d , k e L y / b) =

(NDS Table G1/Figure 3F)

<
E'min =
Fc E
F
c

930000

50

>
CD
0.90

CL
0.99

(Tab. 2.3.2)

849

psi

CF
1.00

f bx = M x / S x =

2146

psi

256

psi

CV
1.00

Cr
1.00

(NDS 4.3.6) (NDS 4.3.9) (NDS 5.3.6) (NDS 5.3.8) (NDS 5.3.9)

2160

F b * = F bx ' / ( C V C L ) =
R B = ( L e d / b 2 ) 0.5 =

,(NDS 3.3.3)

psi
(NDS Eq. 3.3-5)

<
Fb E
F

930000

= 1.20 E' min / R B 2 =

= FbE / Fb* =

50

, (NDS 3.3.3.7)

[Satisfactory]

psi
18921

psi

8.760

F by ' = F b C D C M C t C fu (C F C i C r ) (C V C c C I ) =

>
Where

[Satisfactory]
CI
1.00

Cc
1.00

C L = (1+F) / 1.9 - [((1+F) / 1.9) 2 - F / 0.95] 0.5

E'min =

[Satisfactory]

0.590

CHECK BENDING CAPACITY (NDS Table 4.3.1 & Table 5.3.1)


F bx ' = F b C D C M C t C L (C F C i C r ) (C V C c C I ) =
Where

, (NDS 3.7.1.4)

psi, (Strong Axis Controls.)

= 0.822 E' min / (L e /d) 2 =

= FcE / Fc* =
=
0.9

[Satisfactory]
CT
1.0

Cp
0.53

f by = M y / S y =

2333

psi

123

psi

[Satisfactory]

C fu
1.08
(4.3.7/5.3.7)

CHECK BENDING & COMPRESSION CAPACITY (NDS 3.9.2)

f bx
fc
1
1
+

' +
'

f
Fc
1 f c / F cEy f

c F cEx F bx
bx / F bE

Where

E' x,min =

930000

psi

E' y,min =

830000

psi

f by =
'

F by

F c Ex

= 0.822 E' x,min / (k e L x /d) 2 =

849

psi

F c Ey

= 0.822 E' y,min / (k e L y /b) 2 =

823

psi

0.96

<

F 'cEy

+ 'bx =
F bE

0.66

<

1.0

CHECK SHEAR CAPACITY (NDS Table 4.3.1 & Table 5.3.1)


F v ' = F v C D C M C t (C i ) (C vr ) =
239

>
Where

CD
0.90

C vr
1.0

(Tab. 2.3.2) (NDS 5.3.10)

[Satisfactory]

psi

f v = 3 V / (2 A) =

200

psi

[Satisfactory]

1.0

[Satisfactory]

Sy, (in3)
9.8

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Connection Design for Bending Post at Concrete Column Based on NDS 2012 & ACI 318-11
INPUT DATA & DESIGN SUMMARY
LOADS (ASD)

N=
F=
M=

150
132
396

16

CONCRETE COLUMN SIZE

in thk.

fc' =

CONCRETE STRENGTH

lbs
lbs
ft-lbs
x

BOTH SIDES STRAP SECTION


END DISTANCE OF STEEL

16

10

5.5

in width x

En,s =

1.5

NUMBER OF LAG SCREWS

in thk.

132
341

lbs, at center of screws.)


ft-lbs, at center of screws.)

in width

ksi

Ld =

STRAP EMBEDMENT
TOP SQUARE POST

(
(

3/8

in thk.

in, vertical dimension

10

in

10

in width

n=
I=
S1 =
S2 =

, on each side

LAG SCREW DIAMETER


LAG SCREW SPACING

1/4
4
2

in
in, (if one row input 0)
in

END DISTANCE OF WOOD

En =

in, vertical dimension

LOAD DURATION FACTOR ( Tab 2.3.2, NDS 2012)

CD =

1.6

WET SERVICE FACTOR ( Tab 10.3.3, NDS 2012)

CM =

1.0

Ct =

TEMPERATURE FACTOR ( Tab 10.3.4, NDS 2012)


GROUP ACTION FACTOR APPLY? ( 0 = No, 1 = Yes)

Yes, (

1.0
Cg =

0.894

, NDS 2012, 10.3.6)

THE CONNECTION DESIGN IS ADEQUATE.

ANALYSIS
CHECK POST EDGE, END, & SPACING DISTANCE REQUIREMENTS (NDS 2012, Table 11.5.1A, Table 11.5.1B, & Table 11.5.1C)
Eg =

2.75

in

>

1.5 D

[Satisfactory]

En =

in

>

3.5 D

[Satisfactory]

S=

in

>

3D

[Satisfactory]

CHECK WOOD CAPACITY


2
2 0.5
F = [(FF + FMF) + (FN + FMN) ] =

where

Cg

where

lbs / screw

FMF =

85

lbs / screw, at corner screw

FN =
J=

lbs / screw
2
(in Screw Area)

FMN =

57

lbs / screw, at corner screw

72

1.000

, (geometry factor, NDS 2012, 11.5.1)

C'1 = (actual end distance) / (min end distance for full design value) = En / 7D =

1.000

C'2 = (actual shear area) / (min shear area for full design value) =

1.000

C'3 = (actual spacing) / (min spacing for full design value) = S / 4D =

2.000

m 1 m 2 n

1 R EA

n 1

R EA m n 1m 1m 2 n 1 m

n=
Es As =

9 1/2

1.26E+08 lbs, (Em fr Tab.10.3.6C)


1.000

8 15/32

S=

in, (NDS 2012 tab L2)

T-E=

4 27/32 in, (NDS 2012 tab L2)

where

Z =

150

lbs / screw, (NDS 2012, tab 11J)

ZsA =

120

lbs / screw, (NDS 2012, tab 11J)


o

129

138

lbs / screw, main member allowable capacity (NDS 2012, 11.3.3)

150

lbs / screw, (NDS 2012, tab 11J)

ZmA =

120

lbs / screw, (NDS 2012, tab 11J)

ZT = MIN( Z , ZA ) CD Cg Cd =

0.916

lbs / screw, side member allowable capacity (NDS 2012, 11.3.3)

Z =

35.30

, angle between F & grain for side member at corner screw

Z // Z m A
2
2
Z // sin T  Z m A cos T

T=

0.5

in, (length of thread penetration in main member)

Z sT

where

m = u - (u - 1)

, angle between F & grain for main member at corner screw


115

lbs / corner screw, connection allowable capacity

0.049

22500

, (penetration depth factor, NDS 2012, tab 11J, footnote 3)

P = S + (T - E) - ts =

54.70

J = 180000 D1.5 =

u = 1+J S/2 [1 / EmAm + 1 / EsAs] =

in

Z // Z s A
2
2
Z // sin T  Z s A cos T

Z mT

, (group action factor, NDS 2012, 10.3.6)

REA = Min [(EsAs/EmAm) , (EmAm/EsAs)] =


6187500 lbs, (one side, NDS Table 10.3.6C)

E mA m =

T=

0.894

tm =

Cd = P / (8 D) =
where

lbs / screw, actual load at corner screw

C' = Min (C'1 , C'2 , C'3) =


where

115

FF =

1.004

(Cont'd)
CHECK STEEL STRAP CAPACITIES (AISC 360-10, ASD)
2
in , yielding criterion
Ag =
4.13
Tallow =

0.6 Fy Ag =

89.10

Fy =

>

(0.6 from 1/:t, Typ.)


An =
Tallow =

0.5 Fu An =

103.31

>

149.53

>

58.00

ksi

[Satisfactory]

Tallow =

0.3 Fu Av + 0.5 Fu (0.5 An) =

rmin =

t / (12)

L / rmin =

, (conservatively assumed all screws with the max force to vertical.)


Fu =

ksi
k

in , block shear

5.63

0.5

36.00
1.83

[Satisfactory]

in , fracture criterion

3.56

Av =

T=2nF=

0.108

18

in

L=
200

<

[Satisfactory]
Max (En , S2 ) =

[Satisfactory]

(AISC 360-10 D1)

9.20

<

Ld

0.375

in

[Satisfactory]

in

CHECK STEEL STRAP EMBEDMENT

U
requird 0.02\ ed b f
L dh MAX K
U provided
O f c'

where

K =
U

required

O =

, 8d b , 6 in

[Satisfactory]

0.7
/ U provided =

\e =

1.0

Tallow =

(1 / 1.5) I MIN( 0.2 fc' , 800 ) Ac =


I=

24.75

0.75
82.50

1.0

d b = thk. =

1.0

where

Ac =

in

, (ACI 318-11 12.5.2)

>

, (ACI 318-11 11.6.5)


2

in , all four friction surfaces.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Curved Wood Member (Wood Torsion) Design Based on NDS 2015


INPUT DATA & DESIGN SUMMARY
AXIAL COMPRESSION FORCE
P=
TOTAL CURVED STRONG AXIS EFFECTIVE LENGTH

10

kips, ASD

keLx =
15
ft, (NDS Table G1/Figure 3F)
TOTAL CURVED WEAK AXIS EFFECTIVE LENGTH
keLy =

7.5

ft, (NDS Table G1)

STRONG AXIS BENDING MOMENT

Mx =

0.4

CURVED BENDING EFFECTIVE LENGTH

ft-kips, ASD

Le =

WEAK AXIS BENDING MOMENT

My =

0.1

ft, (NDS Table 3.3.3)

ft-kips, ASD

CRITICAL/MAXIMUM SECTION SHEAR FORCE

V=

2.5

kips, ASD

TORQUE IN THE RECTANGULAR SECTION

T=

0.35

ft-kips, ASD

THE MEMBER DESIGN IS ADEQUATE.


DESIGN VALUES (NDS Supplement Tables or ICC ESR)
Fv
525

Fb
2325

psi ==>

Fc
2170

Ex,min
788000

b, (in)

Ey,min
788000

d, (in)
8.625

3.5

A, (in2)
30.19

Ix, (in4)
187.14

Sx, (in3)
43.39

Iy, (in4)
30.82

ANALYSIS
CHECK COMPRESSION CAPACITY (NDS Table 4.3.1 & Table 5.3.1)
Fc' = Fc CD CM Ct CF Ci Cp =
902
psi
CD
0.90

Where

CM
1.00

>

fc = P / A =

Ct
1.0

CF
1.00

331
Ci
1.0

psi

(Tab. 2.3.2) (4.4.3/5.5.3) (Tab. 2.3.3) (NDS 4.3.6) (NDS 4.3.8)

C P = (1+F) / 2c - [((1+F) / 2c) 2 - F / c] 0.5


Fc* = Fc' / Cp =

1953

(NDS 4.4.2 for Truss only)

,(NDS 3.7.1)

psi

L e / d = Max( k e L x / d , k e L y / b) =

26

(NDS Table G1/Figure 3F)

<
E'min =
FcE

50

= 0.822 E' min / (L e /d) 2 =

>
CL
0.99

CF
1.00

(Tab. 2.3.2)

980

psi

f bx = M x / S x =

2074

psi

111

psi

CV
1.00

Cr
1.00

(NDS 4.3.6) (NDS 4.3.9) (NDS 5.3.6) (NDS 5.3.8) (NDS 5.3.9)

F b * = F bx ' / ( C V C L ) =

2093

R B = ( L e d / b 2 ) 0.5 =

,(NDS 3.3.3)

psi
(NDS Eq. 3.3-5)

<
FbE
F

50

, (NDS 3.3.3.7)

[Satisfactory]

788000 psi

= 1.20 E' min / R B 2 =

= FbE / Fb* =

13990

psi

F by ' = F b C D C M C t C fu (C F C i C r ) (C V C c C I ) =

>
Where

[Satisfactory]
CI
1.00

Cc
1.00

C L = (1+F) / 1.9 - [((1+F) / 1.9) 2 - F / 0.95] 0.5

E'min =

[Satisfactory]

0.502

CHECK BENDING CAPACITY (NDS Table 4.3.1 & Table 5.3.1)


F bx ' = F b C D C M C t C L (C F C i C r ) (C V C c C I ) =
CD
0.90

, (NDS 3.7.1.4)

788000 psi, (Weak Axis Controls.)

F = FcE / Fc* =
c =
0.9

Where

[Satisfactory]
CT
1.0

Cp
0.46

f by = M y / S y =

2171

psi

68

psi

[Satisfactory]

C fu
1.04
(4.3.7/5.3.7)

CHECK BENDING & COMPRESSION CAPACITY (NDS 3.9.2)

f bx
fc
1
1


' 
'
1 f F
F

cEx
Fc
bx

1  f c / F cEy  f bx / F bE

Where

F 'cEy

E' x,min =

788000 psi

E' y,min =

788000 psi

f by
'
F by

F c Ex

= 0.822 E' x,min / (k e L x /d) 2 =

1487

psi

F c Ey

= 0.822 E' y,min / (k e L y /b) 2 =

980

psi

 'bx
F bE

0.36

<

1.0

[Satisfactory]

0.25

<

1.0

[Satisfactory]

Sy, (in3)
17.61

(Cont'd)
CHECK SHEAR CAPACITY (NDS Table 4.3.1 & Table 5.3.1)
F v ' = F v C D C M C t (C i ) (C vr ) =
473

>
Where

CD
0.90

fv + fs =

psi
273

psi

[Satisfactory]

C vr
1.0

(Tab. 2.3.2) (NDS 5.3.10)

f v = 3 V / (2 A) =

124

psi

f s = T ( 1.5 d + 0.9 b) / 0.5 d 2 b 2 =

148

psi, (torsional stress)

CHECK TORSION CAPACITY (Wood Engineering and Construction Handbook, Page 4.17)
158
psi
>
fs =
148
psi
Fs' = Fv' / 3 =

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

4E-SMF with Wood Nailer Design Based on AISC 358-10 & NDS 2012
INPUT DATA & SUMMARY
COLUMN SIZE

W12X96

BEAM SIZE

W18X35

DIMENSIONS
H=

15

ft

L=

30

ft

L1 =

14

ft

LOADS (ASD)
P=
12
F=
5.8
w=

kips, (downward)
kips, (horiz. to right)

1475

lbs / ft, (downward)


Yes

BASE PINNED ?

, (pinned)

BEAM & COLUMN RIGID-ZONE

75 % of (d / 2)

BEAM TO COLUMN BOLTS


I = 1 1/16 in, (Total 2 x 2 x 4 for two moment connections)
GRADES (A325 or A490)

A325
tp =

PLATE & SHIM


NAILER TYPE

3/4

in

Douglas Fir-Larch, G=0.5

THE DESIGN IS ADEQUATE.

( 0=Douglas Fir-Larch, 1=Douglas Fir-Larch(N),


2=Hem-Fir(N), 3=Hem-Fir, 4=Spruce-Pine-Fir)
BEAM NAILER SIZE

thk.

width

THREAD STUD DIAMETER

I =

3/4

THREAD STUD SPACING

S=

12

in

RX =

-6.13

&

11.93

kips

END DISTANCE OF WOOD

En =

in

RY =

25.29

&

30.96

kips

RM =

0.00

&

0.00

ft-kips

LOAD DURATION FACTOR ( Tab 2.3.2, NDS 2012)

CD =

Left

1.6

Right

ANALYSIS
CHECK STORY DRIFT AND BEAM DEFLECTION
'L,drift =

0.6238

in, (horiz. to right)

'R,drift =

0.6095

in, (horiz. to right)

Gxe,allowable, ASD = 'a I / (1.4 Cd), (ASCE 7 12.8.6) =

<
[Satisfactory]

Cd =

'a =

0.02

I=
'max, Beam / L =

1 / 381

<

1/360

, (2012 IBC Tab 1603)

0.6429

hsx, (ASCE 7 Tab 12.12-1)


, (2012 IBC Tab 1604.5 & ASCE 7 Tab 11.5-1)

[Satisfactory]

CHECK BEAM NAILER CONNECTION


T = ABS (-F) =

5.8

n=

27

kips
, number of thread studs

Eg =

2.75

in

>

1.5 D

En =

in

>

3.5 D

S=

12

in

>

C' = Min (C'1 , C'2 , C'3) =


Cg

0.762

3D
, (geometry factor, NDS 2012, 11.5.1)

m 1 m 2 n

1 R EA
n 1
n 1m 1 2 n
1 m


R EA m
m

ZII =

1720

Z'II =

n ZII CD CM Ct Cg C' =

0.185

, (group action factor, NDS 2012, 10.3.6)

lbs / stud, (interpolated from Tab 11E, NDS 2012, Page 85 or Tab 11B, NDS 2012)
10.484

kips

>

[Satisfactory]

CHECK 4-BOLTED UNSTIFFENED END PLATE MOMENT CONNECTION


g=

5.00

in

Pf =

1.75

in

c=

3.93

in

bp =

9.00

in

[Satisfactory]
1.

LOCAL BUCKLING LIMITATIONS (AISC 341-10 Tab. D1.1)

2.

BEAM - COLUMN RATIO REQUIREMENT (AISC 341-10 Sec. E3.4a)

3.

BENDING MOMENT AT THE COLUMN FACE (FEMA 350 3.6.1.1.2)

4.

SHEAR CAPACITY AT THE COLUMN FACE (FEMA 350 3.6.1.1.3)

5.

END PLATE THICKNESS (AISC 358-10 Eq 6.10-13)

[Satisfactory]
[Satisfactory]
[Satisfactory]
[Satisfactory]
[Satisfactory]
6.

CONTINUITY PLATE REQUIREMENT (AISC 358-10 Eq 6.10-13, FEMA 3.3.3.1)


[Satisfactory]

in

,(ASCE 7 Tab 12.2-1)

(Continuity column stiffeners 7/16 x 6


with 1/4" fillet weld to web & CP to flanges.
A doubler plate is not required. )

PROJECT :
PAGE :
CLIENT :
DESIGN BY :
JOB NO. :
DATE :
REVIEW BY :
Two-Way Floor Design Based on NDS 2015, using Cross-Laminated Timber (CLT), by Finite Element Method
INPUT DATA & DESIGN SUMMARY
CLT PANEL SIZE

CLT PANEL THICKNESS

W=
L=
t=

4.5

CONNECTION TYPE ( 0 or 1)

DESIGN VALUES (NDS 10.2)

8
12

ft, (2438 mm)


ft, (3658 mm)

in, (114 mm)


, only corner pinned.

Fb' =

2.1

ksi, ASD

2
(14 N / mm )

Fv' =

0.5

ksi, ASD

2
(3 N / mm )

E' =

900

ksi, ASD

(6207 N / mm )

ALLOWABLE DEFLECTION

L / 240
w=
P=

UNIFORM LOAD (Including Wt., perpendicular to Plane)

POINT LOAD (Including Impact Factor)

100
0.5

psf, ASD level


kips, ASD level

THE DESIGN IS ADEQUATE.


ANALYSIS
CLT PROPERTIES
G=
J =
Weight =
X =

0.55
34
1236
0.45

, Specific gravity
3
3
lbs / ft (2500 kg / m )
lbs, (561 kg)
, Poisson's ratio

JOINT DEFLECTIONS, REACTIONS, & PLATE SECTION FORCES


kips,( Point load at Joint 9.)
P=
0.5
Joint
Number
1
2
3
4
5
6
7
8
9

R
kips
-2.53

'
in
0
0.44
0.62
0.10
0.44
0.58
0.14
0.44
0.57

Bending

Section
7-8
8-9
3-6
6-9

CHECK BENDING CAPACITY


Mn / : b = Fb' d t2/ 6 =

85.05

M
ft-k/ft
1.37
1.22
3.02
2.86

>

ft-k/ft

M =

3.11

ft-k/ft

1.79

kips/ft

[Satisfactory]
Where

d=
12
in, (1 ft)
2
2 0.5
M = (M 6-9 + M 8-9 )
=
3.11

CHECK SHEAR CAPACITY


V n / : v = (2/3) F v ' d t =
Where

V = Max(R , P) / (2 ft )

CHECK DEFLECTION
' max =
0.57
Where

18.00

in

L = Max (L , W) =

0.5

ft-k/ft

>
V=
[Satisfactory]
1.7854 kips/ft

kips/ft

<
[Satisfactory]
144.0 in

L / 240

0.60

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Hybrid Member (Wood & Metal) Design Based on NDS 2015, AISI S100 & ICBO ER-4943P
DESIGN CRITERIA
1. The only axial and strong axis bending have been calculated for the metal track capacity. The metal on wood has no buckling capacity reduction.
2. The shear force/load is fully supported by wood, so the metal can be nailed to existing structure on job site, without connection changes.

INPUT DATA & DESIGN SUMMARY


AXIAL COMPRESSION FORCE
P=
TOTAL HYBRID STRONG AXIS EFFECTIVE LENGTH

50

kips, ASD

keLx =
15
ft, (NDS Table G1/Figure 3F)
TOTAL HYBRID WEAK AXIS EFFECTIVE LENGTH
keLy =
7.5
ft, (NDS Table G1)
STRONG AXIS BENDING MOMENT

Mx =

HYBRID BENDING EFFECTIVE LENGTH

ft-kips, ASD

Le =

WEAK AXIS BENDING MOMENT

My =

0.1

ft, (NDS Table 3.3.3)

ft-kips, ASD

CRITICAL/MAXIMUM SECTION SHEAR FORCE

V=

2.5

kips, ASD

TORQUE IN THE RECTANGULAR SECTION

T=

0.35

ft-kips, ASD

THE MEMBER DESIGN IS ADEQUATE.


WOOD DESIGN VALUES (NDS Supplement Tables or ICC ESR)
psi ==>

Fb
2325

Fv
525

Fc
2170

Ex,min
788000

b, (in)

Ey,min
788000

d, (in)
8.625

3.5

A, (in )
30.19

Ix, (in4)
187.14

Sx, (in3)
43.39

METAL DESIGN VALUES (AISI S100 & ICBO ER-4943P)


A, (in2)
Fy
Sx, (in3)
ksi ==>

50

1.17

1.80

ANALYSIS
CHECK COMPRESSION CAPACITY (AISI D6, NDS Table 4.3.1 & Table 5.3.1)
Fc ' = Fc CD CM Ct CF Ci Cp =
902
psi
f c = (P - F y A/ : c ) / A =

>
CD
0.90

Where

CM
1.00

CF
1.00

Ct
1.0

Ci
1.0

576

(Tab. 2.3.2) (4.4.3/5.5.3) (Tab. 2.3.3) (NDS 4.3.6) (NDS 4.3.8)

:c =

Fc * = Fc ' / Cp =

- F / c]

1953

0.5

(NDS 4.4.2 for Truss only)

,(NDS 3.7.1)

psi

L e / d = Max( k e L x / d , k e L y / b) =

26

(NDS Table G1/Figure 3F)

<
E'min =

788000

= 0.822 E' min / (L e /d) 2 =

980

:b =

CL
0.99

CF
1.00

2074

CV
1.00

Cr
1.00

- F / 0.95]

0.5

2093

R B = ( L e d / b 2 ) 0.5 =

[Satisfactory]

,(NDS 3.3.3)

psi
(NDS Eq. 3.3-5)

<
E'min =

788000

= 1.20 E' min / R B 2 =

= FbE / Fb* =

(4.3.7/5.3.7)

, (NDS 3.3.3.7)

[Satisfactory]

13990

psi

>
C fu
1.04

50

psi

F by ' = F b C D C M C t C fu (C F C i C r ) (C V C c C I ) =
Where

psi

CI
1.00

Cc
1.00

1.67

F b * = F bx ' / ( C V C L ) =

psi
417

(NDS 4.3.6) (NDS 4.3.9) (NDS 5.3.6) (NDS 5.3.8) (NDS 5.3.9)

C L = (1+F) / 1.9 - [((1+F) / 1.9)

FbE

[Satisfactory]

psi

f bx = (M x - F y S x / : b )/ S x =

>

(Tab. 2.3.2)

, (NDS 3.7.1.4)

0.502

CHECK BENDING CAPACITY (AISI C3, NDS Table 4.3.1 & Table 5.3.1)
F bx ' = F b C D C M C t C L (C F C i C r ) (C V C c C I ) =
CD
0.90

50

psi, (Weak Axis Controls.)

F = FcE / Fc* =
c =
0.9

Where

[Satisfactory]

1.8

C P = (1+F) / 2c - [((1+F) / 2c)

Fc E

psi

CT
1.0

Cp
0.46

f by = M y / S y =

2171

psi

68

psi

[Satisfactory]

Iy, (in4)
30.82

Sy, (in3)
17.61

(Cont'd)
CHECK BENDING & COMPRESSION CAPACITY (AISI C5 & NDS 3.9.2)

f bx
fc
1
1


' 
'

Fc
1  f c F cEx F bx 1  f c / F cEy  f bx / F bE

Where

F 'cEy

E' x,min =

788000 psi

E' y,min =

788000 psi

'
F cEy

= 0.822 E' x,min / (k e L x /d)

1487

psi

F c Ey

= 0.822 E' y,min / (k e L y /b)

980

psi

<

0.81

<

1.0

0.77

<

0.61

f bx  F y / :b
'
F bE

CHECK SHEAR CAPACITY (NDS Table 4.3.1 & Table 5.3.1)


F v ' = F v C D C M C t (C i ) (C vr ) =
473

>
Where

f
by
'
F by

F c Ex

 'bx
F bE

f c  F y / :c

CD
0.90

fv + fs =

[Satisfactory]

1.0

[Satisfactory]

273

psi

psi
[Satisfactory]

C vr
1.0

(Tab. 2.3.2) (NDS 5.3.10)

f v = 3 V / (2 A) =

124

psi

f s = T ( 1.5 d + 0.9 b) / 0.5 d 2 b 2 =

148

psi, (torsional stress)

CHECK TORSION CAPACITY (Wood Engineering and Construction Handbook, Page 4.17)
Fs ' = Fv ' / 3 =
158
psi
>
fs =
148
psi

[Satisfactory]

1.0

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Joist Design Based on AISI S100-2007 & ICBO ER-4943P


INPUT DATA & DESIGN SUMMARY
600S162-54

SECTION & SPACING

24
in o.c
( 50 ksi )

JOIST SPAN

L=

11.5

ft

DEAD LOAD
LIVE LOAD

DL =
LL =

20
20

psf
psf

LATERAL SUPPORTED ?
(0=No, 1=compression flange, 2=tension flange)
DEFLECTION LIMITATION FOR LIVE LOAD ?
(0=No., 1= L /240, 2= L /360, 3= L /180, 4= L /120)

compression flange

L /240

THE DESIGN IS ADEQUATE.

ANALYSIS
SECTION PROPERTIES OF EACH METAL STUD (SSMA page 7 & 8)
t =

0.0566

in

Fy =

50

ksi

Ixx =

2.86

in4

Mn/b =

27.76 in-kips

h =

in

Wt =

1.89

lb/ft

Sxx =

0.927

in3

Vn/v =

2708

0.556

in2

ry =

0.57

in

A =

rx = 2.267 in

J = 0.000594 in4

xo = -1.072 in

6
Cw = 1.318 in

CHECK MAX WEB DEPTH-TO-THICKNESS RATIO (AISI B1.2)


h/t=
106.01
<
200 [Satisfactory]
CHECK FLEXURAL CAPACITY (AISI C3.1)
b =
Mn/

27.76

>

in-kips

[Satisfactory]

M = [(DL+LL) S + Wt ] L / 8 =
16.24
in-kips
S=
24
in o.c., spacing as given.

Where

CHECK SHEAR CAPACITY (AISI C3.2)


V =
Vn/
Where

2708 lbs
>
V = [(DL+LL) S + Wt ] L / 2 =

V
471

[Satisfactory]
lbs

CHECK LATERAL-TORSIONAL BUCKLING (AISI C3.1.2)


CASE 1: BOTH TOP & BOTTOM FLANGES UNSUPPORTED

Fe =

C b r oA

Where

Sf
Cb =

ey t =

9.0

ksi

<== Does not apply.

<
<

2.78 Fy =

139.0

ksi

0.56 Fy =

28.0

ksi

1.0

ro = (rx2 + ry2 + xo2)0.5 =


Sf =
E=
G=

0.95
29500
11300

2.572 in
in3

ey =

ksi (AISI pg xiv)


ksi (AISI pg xvi)

Ky =

1.0

Kt =

1.0

Ly =

138

in

Lt =

138

in

t =

2E

(K yL y / r y)
1
Ar o2

GJ +

2E C w
=
( K t Lt )2

F y , for F e2.78 F e
Fc =

10 F y
10
F 1
9 y
36 F e

__
, for 2.78> F e 0.56 F e

F e , for F e 0.56 F e

Page 275 of 533


524

9.0

ksi

lbs

4.967

ksi

7.305

ksi

(cont'd)
Mn/
b =

5.16

in-kips

Where

Sc =

0.95

b =

1.67

Mn =

Sc Fc =

<

[Satisfactory]

in3 from SSMA page 7 & 8

8.61

in-kips

M = [(DL+LL) S/12 + Wt ] L2 / 8 =

16.24

CASE 2: BOTTOM FLANGE SUPPORTED ONLY


Mn/
b =
Where

in-kips
<== Does not apply.

>

19.43

in-kips

[Satisfactory]

Se =

0.93

b =
R=

1.67
0.70

(AISI Table D6.1.1-1)

Mn =

RSeFy =

32.45

in3, from Sxx

in-kips

CHECK CAPACITY COMBINED BENDING & SHEAR AT ANY SAME SECTION (AISI C3.3.1)
bM
Mn

Where

vV
Vn

M=
V=

<

0.6105

16.24
471
2708

b =

1.67

lbs

Mn = MIN( Bending , Buckling) =


Mn/b =

0.6

46.359 in-kips

27.76 in-kips, from SSMA page 7 & 8 for bending only.

>

0.59

bM
V
+ v
Vn
Mn

[Satisfactory]

in-kips
lbs

Vn/v =

bM
Mn

1.0

vV
Vn

0.5

<

0.525

1.3

0.17

<

0.7

[Satisfactory]

CHECK DEFLECTION

LL =

5( LL S ) L 4
384 EI xx

0.19

in

<

L /240 =

0.58

in

[Satisfactory]

DETERMINE SCREWS AT EACH LEG OF CONNECTION (SSMA page 48)


Vmax =

471

lbs

vallow =

344
370
384

lbs / screw, for # 8 screws.


lbs / screw, for # 10 screws.
lbs / screw, for # 12 screws.

==>
==>
==>

(2)- # 8 screws required.


(2)- # 10 screws required.
(2)- # 12 screws required.

Technical References:
1. AISI STANDARD, S100-2007 Edition. American Iron and Steel Institute.
2. SSMA, Product Technical Information, ICBO ER-4943P, Steel Stud Manufactures Association, 2001.

__
Page 276 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Box Beam Design Based on AISI S100-2007 & ICBO ER-4943P


INPUT DATA & DESIGN SUMMARY

x
800S250-68
VERT. MEMBERS
3
(TOTAL SECTION: 8 x 8 , 50 ksi )
SPAN

L=

DEAD LOAD
LIVE LOAD

10

ft

0.2
0.36

DL =
LL =

kips / ft
kips / ft

COMPRESSION FLANGE SUPPORTED ? (0=No, 1=Yes)

0
1

DEFLECTION LIMITATION FOR LIVE LOAD ?


(0=No., 1= L /240, 2= L /360, 3= L /180, 4= L /120)

No.

L /240

THE DESIGN IS ADEQUATE.

ANALYSIS
SECTION PROPERTIES OF EACH STUD (SSMA page 7 & 8)
t =

0.0713

in

Fy =

50

ksi

Ixx =

9.261

in4

Mn/b =

59.96 in-kips

h =

in

Wt =

3.33

lb/ft

Sxx =

2.003

in3

Vn/v =

4048

A =

0.978

in2

ry =

0.877

in

rx = 3.077 in

J = 0.001658 in4

6
Cw = 9.526 in

CHECK MAX WEB DEPTH-TO-THICKNESS RATIO (AISI B1.2)


h/t=
112.20
<
200 [Satisfactory]
CHECK FLEXURAL CAPACITY (AISI C3.1)
Mn/
b =

14.99

Where

>

ft-kips

M = (DL + LL + Wt ) L2 / 8 =

M
7.12

[Satisfactory]
ft-kips

CHECK SHEAR CAPACITY (AISI C3.2)


V =
Vn/
Where

12.14 kips
>
V = (DL + LL + Wt ) L / 2 =

V
2.85

[Satisfactory]
kips

CHECK LATERAL-TORSIONAL BUCKLING (AISI C3.1.2.2)

Lu =

0.36C b
F yS f

Where

Fe =
Where

EGJ I y =

1.58

<

ft

Cb =

1.0

Sf =
E=
G=

6.95
29500
11300

Iy =

20.509

ksi (AISI pg xiv)


ksi (AISI pg xvi)
in4 (neglecting top & bottom tracks conservatively.)

J=

0.005

in4

C b
K yL yS f

in3 (total vertical studs, SSMA page 7 & 8.)

EGJ I y =

Ky =

1.0

Ly =

120

22.0

ksi

<
<

2.78 Fy =

139.0

ksi

0.56 Fy =

28.0

ksi

in

F y , for F e 2.78 F y
Fc =

10 F y
10
F y 1
9
36 F e

__
, for 2.78> F e0.56 F y

F e , for F e0.56 F y

Page 277 of 533


524

22.0

ksi

lbs

xo = -1.674 in

(cont'd)
Mn/
b =

7.62

ft-kips

Where

Sc =

6.95

b =

1.67

Mn =

Sc Fc =

>

[Satisfactory]

in3 (total vertical studs, SSMA page 7 & 8.)

152.67 in-kips

M = (DL + LL + Wt ) L2 / 8 =

7.12

ft-kips

CHECK CAPACITY COMBINED BENDING & SHEAR AT ANY SAME SECTION (AISI C3.3.1)
bM
Mn

Where

vV
Vn

M=
V=

7.12
2.85

ft-kips
kips

Vn/v =

12.14

kips

b =

<

0.9643

Mn/b =

0.6

bM
V
+ v
Vn
Mn

[Satisfactory]

1.67

Mn = MIN( Bending , Buckling) =

bM
Mn

1.0

>

0.94

12.72 ft-kips

14.99 ft-kips, for bending only.


vV
Vn

0.5

<

0.7958

1.3

0.23

<

0.7

[Satisfactory]

CHECK DEFLECTION

LL =

5( LL ) L 4
=
384 EI

0.10

in

<

L /240 =

0.50

in

[Satisfactory]

Technical References:
1. AISI STANDARD, S100-2007 Edition. American Iron and Steel Institute.
2. SSMA, Product Technical Information, ICBO ER-4943P, Steel Stud Manufactures Association, 2001.

__
Page 278 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Wall Stud Design Based on AISI S100-2007 & ICBO ER-4943P


INPUT DATA & DESIGN SUMMARY
600S162-54

SECTION & SPACING

WALL HEIGHT

16
in o.c
( 50 ksi )

h=

16

ft

hp =

ft

P=

1500

LATERAL LOAD (SD level)

GRAVITY LOAD (ASD level)

w1 =

25

psf

PARAPET LOAD (SD level)


ECCENTRICITY

w2 =
e=

45
0

psf
in

DEFLECTION LIMITATION ?
(0=No., 1= h /240, 2= h /360, 3= h /180, 4= h /120)

h /240

lbs / ft

THE DESIGN IS ADEQUATE.


ANALYSIS
SECTION PROPERTIES OF EACH METAL STUD (SSMA page 7 & 8)
thk =

0.0566

in

Fy =

50

ksi

Ixx =

2.86

in4

Mn/b =

27.76 in-kips

t =

in

Wt =

1.89

lb/ft

Sxx =

0.927

in3

Vn/v =

2708

A =

0.556

in2

ry =

0.57

in

rx = 2.267 in

J = 0.000594 in4

lbs

xo = -1.072 in

6
Cw = 1.318 in

CHECK MAX WEB DEPTH-TO-THICKNESS RATIO (AISI B1.2)


t / (thk) = 106.01
<
200 [Satisfactory]
CHECK FLEXURAL CAPACITY (AISI C3.1)
b =
Mn/
Where

27.76

x = h + hp

M1 =

>

in-kips / stud

( h+ h p )
2h

[Satisfactory]

Pe
=
h w1

7.50 ft
2

2 w1h 2

1.333

M2=

Pe + w1 ( h 2 h 2p ) S =
2

S=

11.25

in-kips / stud

ft o.c., spacing as gaven.

2
p

w2h
S=
2

5.76

M = (1/1.4) MAX( M1 , M2) =

in-kips / stud

8.04

in-kips / stud, (1/1.4 for wind/seismic, from AISI App. A4.1.2, typical)

CHECK SHEAR CAPACITY (AISI C3.2)


Vn/
V =
Where

2708

V1 =

>

lbs / stud

( h + h p ) w1

( h + h p ) w1 + Pe

[Satisfactory]

2h

S = 250

V2 = h w 1 S - V1 =

283

lbs / stud

V3 = hp w2 S =

240

lbs / stud

V = (1/1.4) MAX( V1 , V2 , V3) =

lbs / stud

202 lbs / stud

CHECK CAPACITY COMBINED BENDING & SHEAR AT ROOF/FLOOR SECTION (AISI C3.3.1)
bM
Mn

Where

2
+

vV
Vn

M=
V=

=
4.11
202

0.166

<

1.0

[Satisfactory]

in-kips / stud, (1/1.4 included)


lbs / stud, (1/1.4 included)

Vn/v =

2708

lbs / stud, from SSMA page 7 & 8.

Mn/b =

27.76

in-kips / stud, from SSMA page 7 & 8.

(cont'd)

bM
Mn

0.6

<

0.15

bM
V
+ v
Vn
Mn

vV
Vn

0.5

<

0.1637

1.3

0.07

<

0.7

[Satisfactory]

CHECK COMPRESSION CAPACITY WITH, AT LEAST, ONE FLANGE THROUGH-FASTENED TO SHEATHING (AISI D6.1.3)
Pn/
c =
Where

4.99

kips / stud

c =

1.8

>

Pn = C1C2C3 AE / 29500 =
C1 = (0.79 x + 0.54) =

P
8.97

[Satisfactory]
kips / stud

0.949

C2 = (1.17 t + 0.93) =

0.996

C3 = (2.5b - 1.63d) + 22.8 =


17.070
E=
29500
ksi (AISI pg xiv)
P=
2.30
kips / stud (included wall weight, 18psf.)
CHECK CAPACITY COMBINED AXIAL LOAD & BENDING (AISI C5.2.1)

cP b C mM
+
=
Pn
M n
Where

0.82

<

1.0

[Satisfactory]

M=
P=

8.04
2.30

in-kips / stud, (1/1.4 included)


kips / stud

Pn/c =

4.99

kips / stud

Mn/b =

27.76

in-kips / stud

Cm =

1.0

P Ex =

2E I x

( K x L x )2

= 1

cP
=
P Ex

22.59

kips / stud

0.817

CHECK DEFLECTION

=
NOTE :

5( w1S ) L 4
384 EI xx

0.58

in

<

h /240 =

0.80

in

[Satisfactory]

1. STUD FLANGES SHALL BE FASTENED TO SHEATHING AT EACH SIDE OF WALL BEFORE VERTICAL LOAD ADDED.

Technical References:
1. AISI STANDARD, S100-2007 Edition. American Iron and Steel Institute.
2. SSMA, Product Technical Information, ICBO ER-4943P, Steel Stud Manufactures Association, 2001.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Jamb/Column Design Based on AISI S100-2007 & ICBO ER-4943P


INPUT DATA & DESIGN SUMMARY

x
400S200-54
VERT. MEMBERS
3
(TOTAL SECTION: 4 x 6 , INSIDE 4 in THK. WALL)
HEIGHT

h=

( 50 ksi )

ft

SERVICE GRAVITY LOAD


SERVICE LATERAL LOAD

6.8
0.33

P=
w=

kips
kips / ft

DEFLECTION LIMITATION ?
1
h /240
(0=No., 1= h /240, 2= h /360, 3= h /180, 4= h /120)

THE DESIGN IS ADEQUATE.

ANALYSIS
SECTION PROPERTIES OF EACH VERTICAL STUD (SSMA page 7 & 8)
0.0566

in

Fy =

50

ksi

Ixx =

1.292

in4

Mn/b =

17.36 in-kips

in

Wt =

1.7

lb/ft

Sxx =

0.58

in3

Vn/v =

3446

0.5

in2

rx =

1.608

in

ry =

0.758

in

J = 0.000534 in4

Cw =

1.068

in6

thk =
t =
A =

xo = -1.695 in

CHECK MAX WEB DEPTH-TO-THICKNESS RATIO (AISI B1.2)


t / (thk) =
70.67
<
200 [Satisfactory]
CHECK FLEXURAL CAPACITY (AISI C3.1)
b =
Mn/
Where

4.34

>

ft-kips

M = (1/1.4) w h2 / 8 =

2.39

[Satisfactory]

ft-kips, (1/1.4 for wind/seismic, from AISI App. A4.1.2, typical)

CHECK SHEAR CAPACITY (AISI C3.2)


V =
Vn/
Where

10.34 kips
V = (1/1.4) w L / 2 =

>
1.06

[Satisfactory]

kips

CHECK COMPRESSION CAPACITY WITH, AT LEAST, ONE FLANGE THROUGH-FASTENED TO SHEATHING (AISI D6.1.3)
c =
Pn/
Where

15.41

kips

c =

1.8

>

Pn = C1C2C3 AE / 29500 =
C1 = (0.79 x + 0.54) =

P
27.73

[Satisfactory]
kips

0.956

C2 = (1.17 t + 0.93) =

0.996

C3 = (2.5b - 1.63d) + 22.8 =


19.405
E=
29500
ksi (AISI pg xiv)
P=
6.85
kips (included studs weight.)
CHECK CAPACITY COMBINED BENDING & SHEAR AT ANY SAME SECTION (AISI C3.3.1)
bM
Mn

Where

bM
Mn
0.6

2
+

vV
Vn

<

0.5594

1.0

M=
V=

2.39
1.06

ft-kips, (1/1.4 included)


kips, (1/1.4 included)

Vn/v =

10.34

kips

Mn/b =

4.34

ft-kips

bM
V
+ v
Vn
Mn

>

0.55

[Satisfactory]

vV
Vn

0.5

__
0.4325

<

1.3

Page 281 of 533


524

[Satisfactory]

0.10

lbs

<

0.7

(cont'd)
CHECK CAPACITY COMBINED AXIAL LOAD & BENDING (AISI C5.2.1)

cP b C mM
+
=
Pn
M n
Where

0.89

<

1.0

[Satisfactory]

M=
P=

1.70
6.85

ft-kips, (1/1.4 included)


kips

Pn/c =

15.41

kips

Mn/b =

4.34

in-kips

Cm =
P Ex =

1.0

2E I x

( K x L x )2

= 1

cP
=
P Ex

96.75

kips

0.873

CHECK DEFLECTION

NOTE :

5w L4
=
384 EI

0.43

in

<

h /240 =

0.45

in

[Satisfactory]

1. STUD FLANGES SHALL BE FASTENED TO SHEATHING AT EACH SIDE OF WALL BEFORE VERTICAL LOAD ADDED.

Technical References:
1. AISI STANDARD, S100-2007 Edition. American Iron and Steel Institute.
2. SSMA, Product Technical Information, ICBO ER-4943P, Steel Stud Manufactures Association, 2001.

__
Page 282 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Brace Design Based on AISI S100-2007 & ICBO ER-4943P


INPUT DATA & DESIGN SUMMARY
SECTION & SPACING

350S162-33

60

in o.c

BRACE LENGTH
BRACE SLOPE

L=
12 /

12
12

ft

WALL LATERAL LOAD, ASD


WALL HEIGHT

Fp =
H=

5
16

psf
ft

THE DESIGN IS ADEQUATE.


ANALYSIS
Check Brace Compression Capacity (AISI C4.1)
P=
Fp ( 0.5 H) S / Cos = 0.283
c =
Pn/
Where

0.67

kips / brace

c =

1.8

Ae =
ry =
E=
KL / ry =

0.258
0.617
29500
233

Fy =

33

[Satisfactory]

in2 (SSMA page 6-7, ICBO ER-4943P)


in (SSMA page 6-7, ICBO ER-4943P)
ksi (AISI pg xiv)
>
200

Fe = 2 E / (KL / ry)2 =
C = (Fy / Fe)0.5 =

kips / brace

>

[Caution! but Not Mandatory, AISI Commentary page 86]


ksi

ksi
2.48

0.658 F y , for c 1.5


=
F n 0.877
, for c > 1.5
2 Fy
c
2
c

Pn = Ae Fn =
NOTE :

1.21

4.7

ksi

kips / brace

THE LATERAL LOADS MAY BE REDUCED BY (1/1.4) PER AISI APPENDIX A.4.1.2 .

Technical References:
1. AISI STANDARD, S100-2007 Edition. American Iron and Steel Institute.
2. SSMA, Product Technical Information, ICBO ER-4943P, Steel Stud Manufactures Association, 2001.

__
Page 283 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Connection Design of Jamb to Track Based on AISI S100-2007 & ICBO ER-4943P
INPUT DATA & DESIGN SUMMARY
3
x
600S137-68
JAMB MEMBERS
(TOTAL SECTION: 6 x 5 , INSIDE 6 in THK. WALL)
TOP TRACK

600T200-54

JAMB LATERAL LOAD

( 16 GA , 50 ksi )
0.2

F=

kips

THE DESIGN IS ADEQUATE.


ANALYSIS
SECTION PROPERTIES OF TOP TRACK (SSMA page 10 & 11)
t =
2
in, leg length
Fy =
thk =
wall =

50
0.0566
6

ksi
in, metal thickness
in, wall thickness

<
track width
[Satisfactory]

CHECK BENDING CAPACITY OF TRACK LEG


d =
5
in, jamb width
o
11.9
b = d + 2 t (tan 60 ) =
M = F (t + 1/4") / 2 =
2
S = b (thk) / 6 =

in, effective width


in-kips
3
0.0064 in

fb = M / S =

35

0.2

ksi

<

(4/3) Fy [Satisfactory]

(If jamb lateral load have reduced (1/1.4), the factor 4/3 does not apply. AISI App. A4.1.2)

Technical References:
1. AISI STANDARD, S100-2007 Edition. American Iron and Steel Institute.
2. SSMA, Product Technical Information, ICBO ER-4943P, Steel Stud Manufactures Association, 2001.

__
Page 284 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Metal Shear Wall Design Based on AISI S100-2007, ER-5762 & ER-4943P
INPUT DATA
LATERAL FORCE ON DIAPHRAGM:
GRAVITY LOADS
DIMENSIONS:

vdia, WIND =
vdia, SEISMIC =
wDL =
wLL =

350

plf,for wind

500

plf,for seismic

262

plf,for dead load

plf,for live load

Lw =

ft , h =

16

ft

L =

10

ft , hp =

ft

18

Gage

Screws

WALL STUD GAGE ( 20, 18 or 16)


FASTENERS ATTACHING PANELS

EDGE STUD SECTION

600S200-68

DESIGN SUMMARY
ONE SIDE SURE-BOARD SERIES 200 STRUCTURAL PANEL
WITH # 8 SCREWS @ 4" O.C.AT EDGES AND 12" O.C. FIELD.
WITH 18 GAGE METAL STUDS @ 24" O.C. MAX.

THE SHEAR WALL IS ADEQUATE.

WITH #10 SCREWS OF SOLE NAILING (OR 0.145" DIA PINS) @ 3" O.C.
OR WITH 5/8" DIA ANCHOR BOLTS @ 24" O.C. AT FOUNDATION.
HOLD-DOWN FORCES:
DRAG STRUT FORCES:
EDGE STUD:

TL =
F=
2

8.27
k ,
1.00
k
600S200-68

s =

SHEAR WALL DEFLECTION:

0.23

TR =

8.86

(USE S/HD10 - 7/8 DIA BOLTS - 30 # 10)

in

ANALYSIS
CHECK MAX. SHEAR WALL DIMENSION RATIO
L/B =

2.0

<

2 1/4

(from DSA PA-132)

[Satisfactory]

CHECK SHEAR STRESS CAPACITY


vb =

625

plf

vallowable =

<

770

plf

(ASD, from ER-5762, Table 1)

[Satisfactory]
DETERMINE DRAG STRUT FORCE
F = (L-Lw) MAX( vdia, WIND, 0vdia, SEISMIC ) =

1.00

kips

( 0

DETERMINE HOLD-DOWN FORCES

WIND

Wall Seismic
at mid-story (lbs)

Overturning
Moments (ft-lbs)

500

230

82074

350

56000

Resisting
Moments (ft-lbs)

Safety
Factors

Net Uplift
(lbs)

Left

17708

0.9

TL =

8267

Right

12468

0.9

TR =

8857

Left

17708

2/3

TL =

5524

Right

12468

2/3

TR =

5961

Holddown
SIMPSON

S/
HD
10

SEISMIC

vdia
(plf)

(TL & TR values should include upper level UPLIFT forces if applicable)
DETERMINE MAXIMUM SHEAR WALL DEFLECTION (ER-5762 Table 1 & DSA PA-132)
s =

0.13

MAX ( h / 9'-0" , 1 ) =

0.231

in

CHECK EDGE STUD CAPACITY (AISI S100-2007 & ER-4943P)


Pn/c =

13.18

kips

>

Pmax =

8.32

kips, (this value should include upper level DOWNWARD loads if applicable)

[Satisfactory]
Where

c =

1.8

Pn = C1C2C3 AE / 29500 =
C1 = (0.79 x + 0.54) =
C3 = (2.5b - 1.63d) + 22.8 =
29500

__
kips

0.949

C2 = (1.17 t + 0.93) =
E=

23.73

1.013

16.145

ksi (AISI pg xiv)

Page 285 of 533


524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Metal Shear Wall with an Opening Based on AISI S100-2007, ER-5762 & ER-4943P
INPUT DATA
vdia, WIND =
vdia, SEISMIC =

LATERAL FORCE ON DIAPHRAGM:


(SERVICE LOADS)

DIMENSIONS:

268

plf,for wind

350

plf,for seismic

L1 =

ft , L2 =

16

ft , L3 =

ft

H1 =

ft , H2 =

ft , H3 =

6.5

ft

WALL STUD GAGE ( 20, 18 or 16)


FASTENERS ATTACHING PANELS

18

Gage

Screws

EDGE STUD SECTION

600S162-54

KING STUD SECTION

600S162-54

THE SHEAR WALL IS ADEQUATE.


DESIGN SUMMARY
BOTH SIDES SURE-BOARD SERIES 200 STRUCTURAL PANEL
WITH # 8 SCREWS @ 6" O.C.AT EDGES AND 12" O.C. FIELD.
WITH 18 GAGE METAL STUDS @ 24" O.C. MAX.
WITH #10 SCREWS OF SOLE NAILING (OR 0.145" DIA PINS) @ 2" O.C.
OR WITH 5/8" DIA ANCHOR BOLTS @ 16" O.C. AT FOUNDATION.
HOLD-DOWN FORCES:

TL =

5.99

k ,

MAX. STRAP FORCE:

TS =

4.68

TR =

5.99

EDGE STUD:

600S162-54

, CONTINUOUS FULL HEIGHT.

KING STUD:

600S162-54

, CONTINUOUS FULL HEIGHT.

SHEAR WALL DEFLECTION:

s =

0.40

in

__
Page 286 of 533
524

(USE S/LTT20 - 1/2 DIA BOLTS - 5 # 10)

(cont'd)

ANALYSIS
CHECK MAX. SHEAR WALL DIMENSION RATIO
L/B =

1.5

<

2 1/4

(from DSA PA-132)

[Satisfactory]

DETERMINE FORCES & SHEAR STRESS OF FREE-BODY INDIVIDUAL PANELS OF WALL


INDIVIDUAL PANEL

W (ft)

H (ft)

MAX SHEAR STRESS (plf)

NO.

FORCE (lbf)

NO.

FORCE (lbf)

4.00

6.50

27

F1

108

F13

3325

8.00

6.50

512

F2

4092

F14

3325

8.00

6.50

512

F3

108

F15

6475

4.00

6.50

27

F4

3325

F16

3150

4.00

3.00

1050

F5

4200

F17

3150

4.00

3.00

1050

F6

4092

F18

6475

4.00

3.00

1050

F7

4092

F19

4682

4.00

3.00

1050

F8

4200

F20

4682

4.00

4.00

-121

F9

175

F21

2668

10

8.00

4.00

667

F10

3150

F22

-482

11

8.00

4.00

667

F11

3150

F23

4682

12

4.00

4.00

-121

F12

175

F24

-482

CHECK SHEAR STRESS CAPACITY


vb =

1050

plf

vallowable =

<

1124

plf

(ASD, from ER-5762, Table 1)

[Satisfactory]
DETERMINE HOLD-DOWN FORCES

SEISMIC
WIND

350

Overturning
Moments (ft-lbs)

634

143827

268

106128

Resisting
Moments (ft-lbs)

Safety
Factors

Net Uplift
(lbs)

Left

0.9

TL =

Right

0.9

TR =

5993

Left

2/3

TL =

4422

2/3

TR =

4422

Right

Holddown
SIMPSON

5993
S/
LT
T2
0

THE HOLD-DOWN FORCES:


vdia
Wall Seismic
at mid-story (lbs)
(plf)

(TL & TR values should include upper level UPLIFT forces if applicable)
DETERMINE MAXIMUM SHEAR WALL DEFLECTION (ER-5762 Table 1 & DSA PA-132)
s =

0.22

MAX ( h / 9'-0" , 1 ) =

0.403

in

CHECK EDGE STUD CAPACITY (AISI S100-2007 & ER-4943P)


Pn/c =

9.43

kips

>

Pmax =

5.99

kips, (this value should include upper level DOWNWARD loads if applicable)

[Satisfactory]
Where

c =

1.8

Pn = C1C2C3 AE / 29500 =

16.98

C1 = (0.79 x + 0.54) =

0.949

C2 = (1.17 t + 0.93) =

0.996

C3 = (2.5b - 1.63d) + 22.8 =

16.145

E=

29500

kips

ksi (AISI pg xiv)

CHECK KING STUD CAPACITY (AISI S100-2007 & ER-4943P)


Pn/c =

9.43

kips

>

Pmax =

3.15

kips

[Satisfactory]
Where

Pn = C1C2C3 AE / 29500 =

16.98

C1 = (0.79 x + 0.54) =

0.949

C2 = (1.17 t + 0.93) =

0.996

C3 = (2.5b - 1.63d) + 22.8 =

16.145

kips

__
Page 287 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Metal Z-Purlins Design Based on AISI S100-2007


INPUT DATA & DESIGN SUMMARY
10ZS2.25x85

SECTION & SPACING

24

4 : 12 ( 18.43
L=
25
ft

ROOF SLOPE
MAXIMUM PURLIN SPAN

Fy =
DL =
LR =
WIND =

YIELD STRESS (33 or 55)


SLOPED DEAD LOAD
PROJECTED ROOF LIVE LOAD
NET UPWARD WIND PRESSURE

55
8
20
25

in o.c
0

ksi
psf
psf
psf

LATERAL SUPPORTED BY DIAPHRAGM?


(0=No, 1=top flange, 2=bottom flange)
DEFLECTION LIMITATION FOR LIVE LOAD ?
(0=No., 1= L /240, 2= L /360, 3= L /180, 4= L /120)

top flange

L /240

THE DESIGN IS ADEQUATE.


ANALYSIS
SECTION PROPERTIES OF EACH Z PURLIN (AISI Manual, 2002, Table I-4 & Table II-4)
0.085
10

A =

1.36

in
in
in2

ry = 1.08 in
Wt = 4.6278 lb/ft
rx =

3.74

in

Cw =

30

in6

J = 0.00326 in4

t =
D =

Ie =

18.8

in

Mn =

194

in-kips

Se =
B =

3.53
2.25

in3
in

Vn =
d =

9.25
0.96

R =

0.1875

in

Sx =

3.79

lbs
in
in3

CHECK MAX WEB DEPTH-TO-THICKNESS RATIO (AISI B1.2)


<
200 [Satisfactory]
D/t=
117.65
DETERMINE ASD LEVEL LOADS
wDL+LR = [(DL Cos + LR Cos2 ) S + Wt Cos ] =
Mmid = wDL+LR L2 / 8 =

55.569 lb/ft, down inward to roof

52.096 in-kips, conservative value at middle of span

Msupport = - wDL+LR L2 / 12 =

-34.731 in-kips, conservative value at supports

VDL+LR = 2 wDL+LR L / 3 =

0.9262 kips, conservative value at supports

w0.9DL+WIND = [(0.9 DL Cos - WIND) S + Wt Cos ] =

-31.9487 lb/ft, uplift inward to roof

Mmid = w0.9DL+WIND L2 / 8 =

-29.952 in-kips, conservative value at middle of span

Msupport = - w0.9DL+WIND L2 / 12 =

19.968 in-kips, conservative value at supports

V0.9DL+WIND = 2w0.9DL+WIND L / 3 =

-0.5325 kips, conservative value at supports

CHECK FLEXURAL CAPACITY (AISI C3.1)


Mn/
b =
Where

116.17

>

in-kips

M = Max( Mmid, Msupport) =


b =

M
52.10

[Satisfactory]
in-kips

1.67

CHECK SHEAR CAPACITY (AISI C3.2)


V =
Vn/
Where

5.78

>

lbs

V = Max( VDL+LR, V0.9DL+WIND) =


v =

[Satisfactory]

0.9262 lbs

1.60

CHECK LATERAL-TORSIONAL BUCKLING (AISI C3.1.2)


CASE 1: BOTH TOP & BOTTOM FLANGES UNSUPPORTED

Fe =

C b r oA
ey t =
Sf

6.9

ksi

<== Does not apply.

<
<

2.78 Fy =

152.9

ksi

0.56 Fy =

30.8

ksi

(cont'd)
Cb =

Where

1.0

xo =

ro = (rx2 + ry2 + xo2)0.5 =

3.893 in

3.79
29500
11300

Ky =

1.0

Kt =

1.0

Ly =

300

in

Lt =

300

in

2E

ey =

in3, ( Sx )
ksi (AISI pg xiv)
ksi (AISI pg xvi)

Sf =
E=
G=

t =

in

(K yL y / r y)
1
Ar o2

GJ +

2E C w
=
( K t Lt )2

3.773

ksi

6.496

ksi

<

0.7

F y , for F e2.78 F e
10 F y
10
F y 1
9
36 F e

Fc =

, for 2.78> F e 0.56 F e

6.9

ksi

F e , for F e 0.56 F e
b =
Mn/
Where

15.70

in-kips

Sc =

3.79

b =

1.67

Mn =
M=

Sc Fc =
52.10

<

[Satisfactory]

in3

26.21
in-kips

in-kips

CASE 2: TOP OR BOTTOM FLANGE SUPPORTED ONLY


Mn/
b =
Where

>

66.85

in-kips

Se =

3.53

[Satisfactory]

b =
R=

1.67
0.575

(AISI Table D6.1.1-1)

Mn =
M=

RSeFy =
34.73

111.64 in-kips
in-kips

in3

CHECK CAPACITY COMBINED BENDING & SHEAR AT ANY SAME SECTION (AISI C3.3.1)
bM
Mn

Where

vV
Vn

M=
V=

52.10
0.93

Vn/v =

5.78125

<

0.7956

0.6

lbs

>

0.78

bM
V
+ v
Vn
Mn

[Satisfactory]

in-kips
lbs

Mn = MIN( Bending , Buckling) =

bM
Mn

1.0

111.64 in-kips

vV
Vn

0.5

<

0.6278

1.3

0.16

[Satisfactory]

CHECK LIVE LOAD DEFLECTION

LR =
Where

5( w LR ) L 4
384 EI e

wLR = LR Cos2 S =

0.57
36

in

<

L /240 =

1.25

lb/ft, down inward to roof

Technical References:
1. AISI STANDARD, S100-2007 Edition. American Iron and Steel Institute.
2. AISI MANUAL, 2001 Edition. American Iron and Steel Institute.

in

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Seismic Design for Ordinary Concentrically Braced Frames Based on IBC 09 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
Tube
= > HSS6X6X5/8
20
kips
D=
L=
10
kips
QE =
50
kips (ASCE 7-05 12.4.2.1)

BRACE SECTION (Tube or Pipe)


BRACE AXIAL LOAD AT SERVICE LEVEL
BRACE AXIAL LOAD AT HORIZ. SEISMIC

rmin

11.70

2.17

0.58

6.00

SDS = 0.533 (ASCE 7-05 11.4.4)


SEISMIC PARAMETER
THE DESIGN IS ADEQUATE.
UNBRACED LENGTH OF THE BRACE
=
18
ft
BUILDING LIMITATION FOR SDC D or E
H=
28
ft (< 35 ft, ASCE 7-05 Tab. 12.2-1)
REQUIRED CONNECTION = >
( 5/8 in Gusset Plate with 14 in Length, 4 leg, 5/16 in Fillet Weld. Cover Plate 3/4 x 5 at Each Sides.)
CHECK LIMITING WIDTH THICKNESS RATIO ps FOR COMPRESSION ELEMENT, LOCAL BUCKLING (AISC 341-05 Tab. I-8-1)
D / t = 0.044 Es / Fy

27.74 , for Pipe

>

( D / t = 1300 / Fy for AISC-Seismic 97, Tab. 1-9-1)


h / t = 0.64 (Es / Fy)
[ h / t = 110 / (Fy)
Where

0.5

0.5

Actual

[Satisfactory]

16.07 , for Tube

for AISC-Seismic 97, Tab. 1-9-1]

Fy =

46

ksi

Es =

29000

ksi

CHECK LIMITING SLENDERNESS RATIO FOR V OR INVERTED-V CONFIGURATIONS (AISC 341-05 Sec. 14.2)
0.5
K /r=
100.4
>
99.5 [Satisfactory]
4 (Es / Fy) =
[ 720 / (Fy)0.5 for AISC-Seismic 97, Sec. 14.2]
Where

K =

1.0

DETERMINE FACTORED DESIGN LOADS TO WITHSTAND LIMITED INELASTIC DEFORMATIONS (AISC 341-05 Sec.14.1)
Put = 0.9D - (Cd / I ) QE - 0.2SDSD =

-146.6 kips (Tension, ASCE 7-05 Sec. 12.8.6)

Puc = 1.2D + f1L + (Cd / I ) QE + 0.2SDSD =


Where

Cd =
I=
f1 =

3 1/4
1
0.5

193.6

kips (Compression Governs, ASCE 7-05 Sec. 12.8.6)

(ASCE 7-05 Tab. 12.2-1)


(IBC Tab.1604.5)
(IBC 1605.2)

CHECK DESIGN STRENGTH IN COMPRESSION (AISC 360-05 E3)


cPn = cAgFcr =
Where

248.75

c =

0.9

Fe =

2 E / (K

>

kips
/ r)2 =

Puc

[Satisfactory]
(Fy/Fe)

28.891 ksi

Fcr =

c =
(K / r) (Fy / E) =
3.96
DETERMINE CONNECTION DESIGN FORCE (AISC 341-05 Sec. 14.4)
0.5

Put = Min(RyFyAg , 0Pu) =


Where

Ry =

(0.658

0.877 Fe =

387.26 kips (Tension)


1.4

(AISC 341-05 Tab. I-6-1)

0 =
2
DETERMINE BEST FILLET WELD SIZE (AISC 360-05 Sec.J2.2b)
> wMIN =
w=
5/16
in
< wMAX =
[Satisfactory]
DETERMINE REQUIRED WELD LENGTH (AISC 360-05 Sec.J2.4)

( 1.6 for Pipe)

0.1875 in
0.4375 in

L = Put / [(4) Fw (0.707 w)]


= 387.26 / [(4) 0.75 (0.6x70)(0.707x5/16)] =

13.91 in
( USE
14
in )
CHECK DESIGN SHEAR RUPTURE OF SLOTTED BRACE (AISC 360-05 Sec.J4.2)
Pn = (0.6Fu)Anv =
=
Where
Fu =

849.19
0.75
58

kips

>
Put
[Satisfactory]

ksi (LRFD Tab.1-4, Pg. 1-21)


2

in
Anv = 4 t L = 4 x 0.581 x 14 =
32.54
DETERMINE REQUIRED THICKNESS OF GUSSET PLATE (AISC 360-05 Tab. J2.4)

__

5/8
in
tg =
CHECK SHEAR RUPTURE CAPACITY OF GUSSET PLATE (AISC 360-05 Sec.J4.2)
Pn = (0.6Fu)Anu = 456.75
=
0.75
Where
Fu =

58

>

kips

Put

[Satisfactory]

17.50

in

ksi (A36 Steel)

Anu = 2 tg L = 2 x 5/8 x 14 =

Page 290 of 533


524

)Fy =

23.62 kis, for c


N/A

4.71

kis, for c > 4.71

(cont'd)
CHECK TENSION CAPACITY AT SLOTTED BRACE (AISC 360-05 D.2 b)
Pn = Rt Fu Ae = 513.94
=
Where
0.75

kips

>

Put

[Satisfactory]

Fu =
x =

58
ksi (AISC 13th Tab.2-3)
3 h / 8 = 2.25 , for Tube (HSS Specification 2.1-4)
D / = 1.91 , for Pipe (HSS Specification 2.1-3)
U = MIN( 1 - x / L , 0.9 ) =
0.84
,(AISC 360-05 Tab. D3.1.)
2
An = Ag - 2 (tg + 1/8) t =
10.83 in
Ae =

U An =

Rt =
Try Cover Plate

1.3
3/4

Region
HSS
Cover Plate

2.25
3.38

9.09

in

(AISC 341-05 Tab. I-6-1)


x
5
, at Each Sides.
xA

0.5 An
5.41
3.75

12.18
12.66

9.16

24.84

x = 24.84 / 9.16 =
2.71
U = MIN( 1 - x / L , 0.9 ) =
0.81
2
An = 10.83 + 7.50 =
18.33 in
2

Ae = U An = 14.78 in
Thus,

Pn = Rt Fu Ae =
Where

Fu =

771.52
58

kips

>

Put

[Satisfactory]

ksi, use plate value

Rt =
1.2
(AISC 341-05 Tab. I-6-1)
Technical References:
1. AISC 341-05: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, Nov. 16, 2005.
2. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.

__
Page 291 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Seismic Design for Ordinary Concentrically Braced Frames Based on IBC 09 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
WF BRACE SECTION
BRACE AXIAL LOAD AT SERVICE LEVEL

= > W14X370
D = 100 kips

== >

L=

100

kips

BRACE AXIAL LOAD AT HORIZ. SEISMIC

QE =

100

kips (ASCE 7-05 12.4.2.1)

ry

bf

109.00

4.27

3.26

17.90

16.50

tw

tf

1.66

2.66

SDS = 0.533 (ASCE 7-05 11.4.4)

SEISMIC PARAMETER

BRACE YIELD STRESS


Fy =
50
ksi
THE DESIGN IS ADEQUATE.
UNBRACED LENGTH OF THE BRACE
= 31.4 ft
35
ft (< 35 ft, ASCE 7-05 Tab. 12.2-1)
BUILDING LIMITATION FOR SDC D or E
H=
REQUIRED CONNECTION = >
( 2 in Gusset Plate with 8 in Length, 8 leg, 3/4 in Fillet Weld. .)
CHECK LIMITING WIDTH THICKNESS RATIO ps FOR COMPRESSION ELEMENT, LOCAL BUCKLING (AISC 341-05 Tab. I-8-1)
bf / tf = 0.30 (Es / Fy)0.5

>

7.22

Actual

[Satisfactory]

( bf / tf = 52 / (Fy)0.5 for AISC-Seismic 97, Tab. 1-9-1)


Where

Es =

29000

ksi

CHECK LIMITING SLENDERNESS RATIO FOR V OR INVERTED-V CONFIGURATIONS (AISC 341-05 Sec. 14.2)
K /r=
96.3
>
88.2 [Satisfactory]
4 (Es / Fy)0.5 =
[ 720 / (Fy)0.5 for AISC-Seismic 97, Sec. 14.2]
Where

K =

1.0

DETERMINE FACTORED DESIGN LOADS TO WITHSTAND LIMITED INELASTIC DEFORMATIONS (AISC 341-05 Sec.14.1)
Put = 0.9D - (Cd / I ) QE - 0.2SDSD =

-245.7 kips (Tension, ASCE 7-05 Sec. 12.8.6)

Puc = 1.2D + f1L + (Cd / I ) QE + 0.2SDSD =


Where

Cd =
I=
f1 =

3 1/4
1
0.5

505.7

kips (Compression Governs, ASCE 7-05 Sec. 12.8.6)

(ASCE 7-05 Tab. 12.2-1)


(IBC Tab.1604.5)
(IBC 1605.2)

CHECK DESIGN STRENGTH IN COMPRESSION (AISC 360-05 E3)


cPn = cAgFcr =
Where

2777.76

c =

0.9

Fe =

2 E / (K

c =

/ r) =
0.5

(K

>

kips

/ r) (Fy / E)

Puc

[Satisfactory]

36.805 ksi
=

Fcr =

3.66

(0.658

0.877 Fe =

DETERMINE CONNECTION DESIGN FORCE (AISC 341-05 Sec. 14.4)


Put = Min(RyFyAg , 0Pu) =
Where

Ry =

1011.32 kips (Tension)


1.1

(AISC Seismic 02 & 97 Tab. I-6-1)

0 =
2
DETERMINE BEST FILLET WELD SIZE (AISC 360-05 Sec.J2.2b)
> wMIN =
0.3125 in
w=
3/4
in
< wMAX =
0.9375 in
[Satisfactory]
DETERMINE REQUIRED WELD LENGTH (AISC 360-05 Sec.J2.4)
L = Put / [(8) Fw (0.707 w)]
= 1011.32 / [(8) 0.75 (0.6x70)(0.707x3/4)] =

7.57 in
( USE
8
in )
CHECK SHEAR RUPTURE OF SLOTTED CON. PLATES (AISC 360-05 Sec.J4.2)
Pn = (0.6Fu)Anv =
=
Where
Fu =

1386.43
0.75
58

kips

>
Put
[Satisfactory]

ksi (A36 Steel)

in2
Anv = 4 t L = 4 x 1.66 x 8 =
53.12
DETERMINE REQUIRED THICKNESS OF GUSSET PLATE (AISC 360-05 Tab. J2.4)
2
in, Center with Column Web.
tg =
CHECK SHEAR RUPTURE CAPACITY OF GUSSET PLATE (AISC 360-05 Sec.J4.2)

__

Pn = (0.6Fu)Anu = 1670.40
=
0.75
Where
Fu =

58

kips

>

Put

[Satisfactory]

64.00

in2

ksi (A36 Steel)

Anu = 4 tg L = 4 x 2 x 8 =

Page 292 of 533


524

(Fy/Fe)

)Fy =

28.32 kis, for c


N/A

4.71

kis, for c > 4.71

) +

)1 *, 2 3 ( - 4, +

*
,

':( ;

* * C
:4

% %//

:4

% )/

:1D

"

G= :4

##% : 1D

1D

%'

%'

/)

!"

&F%%%

!"

# & I 3# I
=

&

D1D >

6/#.%'

;" ;7

! "

&

&((F# !"

1B

6F)
6/#.%' B #//

6)%.%' B & &


9 <,

5 <,
' ( )*(+ , -.
*
6)%.%'

% )'(

.).#

# )3

% #($'

% /6$'

#6F# ;
#/
0
6)%.%' B / &

/
0

% )1

1
(/F#F
% $'

;@

=
1
;@

-0

* C
':(

4>
*

C *

0
;

'(
/4

' ( )*(+ , -.

!"

8 #./7 > #.&#

/A % '(# A #/
1 0

;&
6& '/
6)%.%' 8 & /

6)%.%'

0
% )1

! "

=
1
;

/')$'
% $'
'(
& 4>

! "
!"

6) 4

& A ':(A #/

B /&
' ( )*(+ , -.

2
#$'%

;&

1D:1

% ($$1

B &/

:G/ 1< % $%$< H


6($&):G/ % $' % )A$% % $%$A':#) H
*

@ ;"7

$.%'

B #& ()

1D

&6)& !"73

' ( )*(+ , -.

%'

6/#.%' 8

-0

B #/#

B #& ()

"" ;

B #/&

6/#.%'

$.%'

6($&) ! "

#/

':#)

&

1D :

1
<

' ( )*(+ , -.

! "

:C :

C :
1

.(.#

%F

,
,;

1
#F6)

6)%.%'

6/#.%' 8

$.%' 8 #& &.#


8 #)%/'
#)%'/

&/($'

0 C

' ( )*(+ , -.

,
.#/)) ! "

B >1B

2
84 6:/A '84 8B= ? "

B #/&H

6#:/
#
%'

3#

B ;

1
FF'

: - I% &

#%
*

: - .% &

&

B4 82

C 2:

"E B F$7

%F .

) %%

"E B F$7 8 #.F.#H

1
4

"E B F$7 8 #.F.#

#%% /

=
,

1
G$&% : 1D

% '(

#)%$ 73

%'

:1D

"

& #$

$.%' #& / & #

%'

,
/

## $%

&$$/ 73

"

"

" :1D

#6%% :1D 3

=:4

! "
! "
! "

4 %8#9"

"$ %%
$.%'## //
2
#
34
!
34 5 6'347
$.%' 8 #& &.#
*
"" 4 2
84 < 4=#/ ; ;>4=7/2>7':#) ; 1 2
24
2
?

1 *
1

) 6() 3 , 464 #"

!"
#"
"

0
0
-0

+(55- 6 (+ 3 7 (

!"73

J/$#

B 9 /$#

!
"
- .%/%

#$

% " & '(


"
0

#$ "
3 "
7 " 8
" 9
%

/;

"

)*
+,

1
),*
& . 2!
. 41 "
56 / $!%
4 " &'& 56 / *
+%
1(
& 3 4 5 ' "
1 "
& 1 *
9 : &4
7

"

"
<%/ =
2%

&
4(

<%/ =
2%

' '

(&
0
'&

&(
&
2!

&

*
(&

+% *
6*2*
+% *
6*2*
5

2!
&
52 2 . * %,

& &1
&
(1(

(1(4'& "
0&
8
& 3 4 5 ' "
& 1 :0
7

.$,5

"
- .%/%

#$

%"

#$ "

00&
1

)*
+,

"

&1

" &(01 *

),*
5$,% +=
2% <2=
$%

"
&
(&
2!
&
% . *2= %6%/% %,>
&
(& >? %*
,@* / <*
,* , 6 / /$ $/2= %%= $*
=* 9,?5 @%/*2 , *$ % 6 %%=
, /$ * 5 < & 5
>? +% *
6*2* 6 / /$ $/2= %%= $*
=* 9,?5 @%/*2 , *$ % 6 %%=
, /$ * 582/ .'5

1&
*

/'(0 ') /('1- * 2

'-&

3*-)/- ')&44 5 &)/ 6 &0 /( 5&(/ *- 353

7"

!"

&
(

'

!"

"+ % !
"+ %

#!$

! ,

&

&

$$

"
#
/
! 01
&
" 01 *4 #%015
"+ % 67 ! !+ ,
: ;1 /
61; < 1= > 9 ;9?1=5> /
;?5#@ 9 /
/
;1 ;/
A ,

&

23
*! 9

& & B

70 @10

# * @ -,

*70 @10

%! @* -,

+ ; D C "5 67

=;3;
&

E"! @* -,

%
%

023

+ ; D C "5 ;C

>> !

:1

! G0

# @

0
B

&

* ;9 295
% %"

*
*
*

"+ % 67 ! !+ ,
67 $ %,
$% ,

#$ + %

:C

@*B @3,!

*B @3, * - @ ,

*
( 9* -

- ?

=;3;

* 2D 3;

# + % ;C
*

L * $%>

C3

#$$

#!

' *
<

>""

* ;9 29,

; D C ! J " 67 +$+ ,

#@

#$ + % ;C ! !7,
8 <(

).

@E*>,
< * " "<,F
#! @E*>, "%* $K" ,* " "K#@ ,F
.

* $ :,

#>$ #
"%

9H

=;3;

%>

:
9H

).

B &

* $ :,

"%" 9
>
'- .
#$ + % ;C
!,
:1

* #$ 1;;/
,
*

95 ;91;3< 1= 2/
:D9 ;7
.
*

#"%

% & '( &) * +

K $$K >
.

& B
!

1?

# !%

4 <(
% & '( &) * +
&*
#$ + % ;C ! ,

&

2H;39 5

* -@ ;,

#$> %
%

:,

29

# + % ;C

! > $,
"+ % ;C

! > $,

% & '( &) * +

"+ % ;C

C
;

!,

#,

!""" "$

C ? C3

=;3;

B &

# + % ;C

+! %"

G* A @ , ) G !

=;3;

&

% & '( &) * +

% & '( &) * +

A@ ,) + !

+*

:1

# + % 67 +>+ ,

!F

&

:1

B /@3

$#

=;3;

C 9

. B

C1:6/

:C

++,

9:

$"

9!
%# !
#$ + % 67 ! ,
#$ + % ;C
:1

%>

:
9:

1?

* #$ 1;;/
,
K ! K>

!,

% & '( &) * +

"%

=;3;

9!

! $$

* @ -,

&

"!!

023

$%

.
.
).

"

!> #!

5023

5023

C8 "

I "

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Bracing Connection Design, with Perpendicular Gusset, Based on CBC/IBC & AISC

DESIGN CRITERIA
This bracing connection, with a added perpendicular Gusset 2 plate, may force the brace buckling in-plane frame. There are no cover plate required
since the Gusset 2 has concave end. This software can determine two gusset dimensions based on geometry and can check the gusset interface
weld capacities on beam and column with moment loads.

INPUT DATA & DESIGN SUMMARY


BRACE AXIAL LOAD AT SERVICE LEVEL
(AISC 341-05 13.3a)

T=

396

ANGLE BETWEEN BRACE & COLUMN

T=

35

THE TWO GUSSET PLATE THICKNESS

tg =

BRACE SECTION (Tube or Pipe)

=>

in

HSS8X8X5/8

rmin

16.40

2.98

0.63

8.00

8.00

=>

W12X65

x-x

, ec =

=>

W16X40

x-x

, eb =

Tube

kips

COLUMN SECTION
ORIENTATION =
BEAM SECTION
ORIENTATION =
4 Legs with 5/8" Fillet Weld
Lg =
19.65
in

L=
Lcv =

11.00
3.00

in
in

2 Legs with 5/8" Fillet Weld

2E=
2D=

16.73
11.27

in
in

6.05

in

8.00

in
D

THE CONNECTION DESIGN IS ADEQUATE.

ANALYSIS
CHECK LIMITING WIDTH THICKNESS RATIO FOR COMPRESSION ELEMENT, LOCAL BUCKLING (AISC 341-05 Tab. I-8-1)
[Satisfactory]
D / t = 0.044 Es / Fy
=
27.74 , for Pipe
Actual
>
0.5
(AISC 360-05, B4.2.d)
=
16.07 , for Tube
b / t = 0.64 (Es / Fy)
Where

Es =

29000

ksi

Fy =

46

ksi

DETERMINE BEST FILLET WELD SIZE PER BRACE THICKNESS (AISC 360-05 J2.2b)
wMIN =
w=
0.625
in
>
0.25 in
( USE w =

0.625

in )

5/8

<
wMAX = (I 0.6 Fu t) / (I 0.707 FEXX) = (0.75 x 0.6 x 58 ksi) t / (0.75 x 0.707 x 70 ksi)
[Satisfactory]
= 1.1795 t =
0.74 in

DETERMINE REQUIRED WELD LENGTH AT BRACE (AISC 360-05 J2.4)


L = : T / [(4) (0.6) FEXX (0.707 w)]
= (2.0) (396.00) / [(4) (0.6) (70) (0.707 x 5/8)] =

10.67

in

( USE L =

11.00 in )
11

DETERMINE REQUIRED CONCAVE END AT GUSSET 2 PLATE (AISC 360-05 J2.4)


Lcv = : Fy Ae / [(4) (0.6) FEXX (0.707 w)]
= (2.0) (46)(2.66) / [(4) (0.6) (70) (0.707 x 5/8)] =

3.29

in

( USE Lcv =

<

0.5 L

3.00

DETERMINE GUSSET DIMENSIONS BASED ON GEOMETRY


bf =

11.4

in , min wide of Gusset 2 plate

Lg =
2E=

19.65
16.7

in
in ,

>
2D=

L
11.3

<

Max( bf,col , bf,bm) =

[Satisfactory]
in

DETERMINE CONNECTION INTERFACE FORCES ( AISC Manual 13th Edition, Page 13-10)
E=
8.37
in
D=
5.63
in
>
(eb + E) tanT - ec =
5.41

in
[The original Uniform Force Method may not apply]

K = eb tanT - ec =

-0.45

D = tan2T + (D / E)2 =
K' = D ( tanT + D / E) =
DIdeal = (K' tanT + K (D / E)2 ) / D =

in
0.9438
7.7394
5.53

in

12.0

in )

[Satisfactory]
in

(cont'd)
8.53

in

r = [(eb + EIdeal) + (ec + DIdeal) ]

20.18

Vc = (EIdeal / r) T =

167.4

kips

Hc = (ec / r) T =

118.7

kips

Vb = (eb / r) T =

157.0

kips

Hb = (DIdeal / r) T =

108.4

kips

2 0.5

Mc = Hc [ EIdeal - E ] =

1.6

Mb = Vb [ DIdeal - D ] =

-1.4

in
T
E

EIdeal = (DIdeal - K) / tanT =

ft-kips

ft-kips
D

CHECK WELD CAPACITY AT INTERFACES (AISC 360-05 J2.4 )


11.32
ksi
fVc = Vc / (4 E 0.707 w) =
fHc = Hc / (4 E 0.707 w) =

8.03

ksi

fMc = 3 Mc / (4 E 0.707 w) =

0.48

ksi

fVb = Vb / (4 D 0.707 w) =

15.76

ksi

fHb = Hb / (4 D 0.707 w) =

10.89

ksi

0.90

ksi

14.16

ksi

19.68

ksi

fMb = 3 Mb / (4 D 0.707 w) =
: =
2.0
2

2 0.5

fv,c = [(fvc) + (fHc+ fMc) ]

fv,b = [(fvb) + (fHb + fMb)2] 0.5 =

<
<

0.6 FEXX / : =

21.00 ksi

[Satisfactory]

0.6 FEXX / : =

21.00 ksi

[Satisfactory]

CHECK SHEAR RUPTURE CAPACITY OF SLOTTED BRACE (AISC 360-05 J4.2)


Rn,rup,brace/ : =(0.6Fu)Anu / : =
Where

Fu =

58

478.5 kips
>
[Satisfactory]

ksi ( AISC Manual 13th Edition, Pg. 2-39)

Anu = 4 t L = 4 x 0.625 x 11 =
: =
2.0

27.50

in2

CHECK SHEAR RUPTURE CAPACITY OF GUSSET 2 PLATE (AISC 360-05 J4.2)


Rn,rup,gusset2/ : = (0.6Fu)Anv2 / : =
Where

Fu =

58

765.6 kips

>

44.00

in2

[Satisfactory]

ksi (A36 Steel)

Anv2 = 2 tg L = 2 x 2 x 11 =
: =
2.0

CHECK SHEAR RUPTURE CAPACITY OF GUSSET 1 PLATE (AISC 360-05 J4.2)


Rn,rup,gusset1/ : = (0.6Fu)Anv1 / : = 949.77 kips
Fu =

Where

58

>

CHECK GUSSET 2 TENSION YIELDING CAPACITY (AISC 360-05 D2 a)


410.19
kips
>
T
Pn/ : = Fybftg/ : =
Fy =

36

[Satisfactory]

54.58

in2

ksi (A36 Steel)

Anv1 = 2 tg (Lg - 3tg) = 2 x 2 x 13.6 =


: =
2.0

Where

[Satisfactory]

ksi (plate value)

CHECK GUSSET 1 & 2 COMPRESSION CAPACITY (AISC 341-05 13.3c)


Pn/ : = Fcrbftg/ : =
403.78
kips
>
T
Where K =
1.2
(SEAOC Vol.3 page 40)
b =
6.88
in, (Gusset 1 effective wide)
in2
A =
32.54
I =
rg = ( I / A )

60.50
0.5

K Lg / rg < 200
Oc =

[Satisfactory]

in4
1.36

in

[Satisfactory]

(KL g / rg) (Fy / E)0.5 =

0.609

Fe =

957.27

ksi (AISC 360-05 E3)

Fcr =

35.44

ksi (AISC 360-05 E3)

CHECK GUSSET 1 & 2 BLOCK SHEAR CAPACITY (AISC 360-05 J4.3)


Rn,guss/ : = Min [0.6FuAnv , 0.6FyAgv] / : + UbsFuAnt/ : =

765.6

>

+ UbsFuAnt/ :
T=

396.0

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Special Concentrically Braced Frames Based on IBC 09 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
= > W14X605
D = 0.24 kips / ft

BEAM SECTION
BEAM DISTRIBUTED SERVICE LOADS

L=
=

0.5
26
0

kips / ft
ft
No

Fy =

50

ksi

BEAM LENGTH
TOP FLANGE CONTINUOUSLY BRACED ?
BEAM YIELD STRESS

=>

A
178

d
20.9

tw
2.60

bf
17.40

tf
4.16

Sx
1040

Ix
10800

rx
7.79

ry
4.55

Zx
1320

k
4.76

THE BEAM DESIGN IS ADEQUATE.

DETERMINE FACTORED AXIAL LOAD ON THE BEAM (AISC 341-05 13.4a)


Pu = 0.5 (RyFyAg + 0.3cPn) cos =
Where

Ry =

1.4

49.46

386.09 kips

(see brace sheet)


o

Fy =

46

ksi (see brace sheet)

Ag =

16.40

in (see brace sheet)

cPn =

439.36

kips (see brace sheet)

CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)


bf / (2tf ) =
0.3 (Es / Fy)0.5 =
2.09
<

h / tw =

4.38

7.22

Es =

Where

[Satisfactory]

29000 ksi

0.5
3.14(Es/Fy) (1-1.54Pu/bPy) =

<

70.01

, for Pu/bPy

(Es/Fy)0.5Max[1.49 , 1.12 (2.33-Pu/bPy)] =


Where b =

[Satisfactory]

, Py = FyA =

0.9

N/A
8900

0.125

, for Pu/bPy > 0.125


kips

DETERMINE UNBALANCED VERTICAL FORCE ON BEAM (AISC 341-05 13.4a)


Qb = (RyFyAg - 0.3cPn) sin =
702.45 kips (Vertical)
DETERMINE FACTORED MOMENT ON THE BEAM (IBC 09 1605.2 & ASCE 7-05 12.4.2.3)
2

Mnt = (1.2D + L)

/ 8 + Qb / 4 =

4632.48

ft-kips

DETERMINE UNBALANCED SEGMENT LENGTH ABOUT X - AND Y - AXES


x

26

ft

13

ft ( AISC Seismic Sec.13.4a ,lateral support at the intersection of chevron braces required.)

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


cPn = cFcrA =
Where

7123.39

c =
K =

>

kips

Pu

[Satisfactory]

0.9
1.0

MAX(K

x/rx,

y/ry)

c =

(K

Fe =

2 E / (K

Fcr =

200

[Satisfactory]

1.663

/ r)2 =

44.47

<

40.05

/ r) (Fy / E)0.5 =

178.4 ksi (AISC 360-05 E3)

ksi (AISC 360-05 E3)

DETERMINE FLEXURAL DESIGN STRENGTH (AISC-AISC 360-05 F1)


Lb =

13.00

ft

L p = 1.76 ry (E / Fyf)0.5 =

L r = 1.95 r ts

E
0.7 F y

M p = Fy Zx =

F cr =

16.06

Jc
S x h0

1+ 0.078

Lb
r ts
Where

1+ 1+ 6.76

5500.0

C b 2E

h0 = d - tf =
1.30

0.7 F y S x h 0
E

Jc

231.67

ft

ft-kips
2

Jc
S x h0

0.5
0.5
r ts =[( Iy Cw) / Sx] =
c =
1.00

Cb =

ft

Lb
r ts

928.14 ksi

__
5.44

16.74

in

, (AISC 360-05 F1)

Page 298 of 533


524

Iy
3680

G
11200

J
869

Cw
258000

(cont'd)

Mn

b Mn

Mp

5500

ft-kips, for L b @ [0 , L p]

MIN{Cb [Mp - (Mp - 0.75 Fy Sx) (Lb - Lp) / (Lr - Lp)] , Mp}

N/A

ft-kips, for L b @ (L p , L r]

MIN(Fcr Sx , Mp)

N/A

ft-kips, for L b @ (L r , Larger)

= 0.9 Mn =

4950

ft-kips

CHECK FLEXURAL CAPACITY (AISC 360-05 C2.1b)


Mu = B1Mnt =
Where

4689.50

Pe1 = EsIx / (K
2

Cm =
=

1.0
1.0

bMnx =

<

ft-kips

x) = 31755

kips

4950

ft-kips

[Satisfactory]

(AISC 360-05 C2.1b)

B1 = MAX[ Cm/(1 - Pu/Pe1) , 1.0] =

1.012

CHECK INTERACTION CAPACITY (AISC 360-05 H1.1)


For Pu/cPn 0.2,

Pu / cPn + 8 / 9 (Mux / bMnx) =

N/A

For Pu/cPn<0.2,

Pu / (2cPn) + Mux / bMnx =

0.97

<

__
Page 299 of 533
524

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Special Concentrically Braced Frames Based on IBC 09 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION
COLUMN AXIAL SERVICE LOADS

= > W8X40
D=
22
kips

=>

A
11.7

L=

29

kips

COLUMN AXIAL LOAD AT HORIZ. SEISMIC


UNBRACED COLUMN LENGTH

QE =
=

18
14

kips, (ASCE 7-05 12.4.2.1)


ft

COLUMN YIELD STRESS (36 or 50)

Fy =

50

ksi

d
8.3

tw
0.36

bf
8.07

-2

Puc = 1.2D + L + QE + 0.2SDSD =


=
1
Where

Ix

rx

ry

Zx

3.53

2.05

40

0.95

THE COLUMN DESIGN IS ADEQUATE.

kips (Tension)
77

kips (Compression, Governs)

CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)


0.3 (Es / Fy)0.5 = 7.22
bf / (2tf ) =
7.21
<
Where
h / tw =

17.62

Es =

[Satisfactory]

29000 ksi

3.14(Es/Fy)0.5(1-1.54Pu/bPy) =

<

N/A

(Es/Fy)0.5Max[1.49 , 1.12 (2.33-Pu/bPy)] =


Where c =

[Satisfactory]

, for Pu/bPy < 0.125


58.89 , for Pu/bPy > 0.125

0.9

Py = Fy A =

585

kips

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


cPn = cFcrA =
Where

321.98

c =
K =
MAX(K

>

Pu

[Satisfactory]

0.9
1.0
x/rx,

y/ry)

c =

(K

Fe =

2 E / (K

Fcr =

kips

<

82.01

/ r) (Fy / E)0.5 =
/ r)2 =

30.58

3.405

200

[Satisfactory]

(AISC 360-05 E2-4, Pg 6-47)

42.557 ksi (AISC 360-05 E3)

ksi (AISC 360-05 E3)

CHECK AMPLIFIED SEISMIC LOAD EFFECTS FOR Pu / f Pn > 0.4 (AISC 341-05 8.3)
Puc / Pn =

0.24

<

0.4

Puc = 1.2D + L + 0QE + 0.2SDSD =


Where

0 =

[Amplified Seismic Load Do Not Need to Checke]


95 kips

<

c P n

__
Page 300 of 533
524

Sx
35.5

146

DETERMINE FACTORED DESIGN LOADS (IBC 09 1605.2 & ASCE 7-05 12.4.2.3)
Put = 0.9D - QE - 0.2SDSD =

tf
0.56

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Special Concentrically Braced Frames Based on IBC 09 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
= > Tube
= > HSS8X8X5/8
D=
22
kips
L=
29
kips
QE =
18
kips, (ASCE 7-05 12.4.2.1)
=
14
ft

COLUMN SECTION
COLUMN AXIAL SERVICE LOADS
COLUMN AXIAL LOAD AT HORIZ. SEISMIC
UNBRACED COLUMN LENGTH
COLUMN YIELD STRESS (42 or 46)

Fy =

46

rmin

16.40

2.98

0.63

8.00

THE COLUMN DESIGN IS ADEQUATE.

ksi

ANALYSIS
CHECK LIMITING WIDTH THICKNESS RATIO FOR COMPRESSION ELEMENT, LOCAL BUCKLING (AISC 341-05 02 Tab. I-8-1)
D / t = 0.044 Es / Fy
h / t = 0.64 (Es / Fy)
Where

0.5

Es =

29000

27.74 , for Pipe

16.07 , for Tube

>

Actual

ksi

DETERMINE FACTORED DESIGN LOADS (IBC 09 1605.2 & ASCE 7-05 12.4.2.3)
Put = 0.9D - QE - 0.2SDSD =

-2

Puc = 1.2D + L + QE + 0.2SDSD =


=
1
Where

kips (Tension)
77

kips (Compression, Governs)

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


cPn = cFcrA =
Where

548.56

c =
K =
MAX(K

>

Pu

[Satisfactory]

0.9
1.0
x/rx,

y/ry)

c =

(K

Fe =

E / (K

Fcr =

kips

/ r) (Fy / E)0.5 =

/ r)2 =

37.17

56.31

<
200
[Satisfactory]

2.243

(AISC 360-05 E2-4, Pg 6-47)

90.279 ksi (AISC 360-05 E3)

ksi (AISC 360-05 E3)

CHECK AMPLIFIED SEISMIC LOAD EFFECTS FOR Pu / f Pn > 0.4 (AISC 341-05 8.3)
Puc / Pn =

0.14

<

0.4

Puc = 1.2D + L + 0QE + 0.2SDSD =


Where

0 =

[Amplified Seismic Load Do Not Need to Checke]


95 kips

<

c P n

__
Page 301 of 533
524

[Satisfactory]

[Satisfactory]
(AISC 360-05, B4.2.d)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Special Concentrically Braced Frames Based on CBC/IBC & AISC
INPUT DATA & DESIGN SUMMARY
BRACE SECTION (Tube or Pipe)

=>

BRACE AXIAL LOAD AT SERVICE LEVEL

HSS8X8X5/8

D=
L=
QE =

SEISMIC AXIAL LOAD (ASCE 7-05 12.4.2.1)

10
10
190

Tube

rmin

16.40

2.98

0.63

8.00

8.00

kips
kips
kips

SDS = 0.877
U= 1

UNBRACED LENGTH OF THE BRACE

L =

20

ft

ANGLE BETWEEN BRACE & COLUMN

T=

36

ANGLE BTW BRACE & GUSSET EDGE

I=

34

COLUMN SECTION

ec =

in

BEAM SECTION

eb =

8.1

in

LENGTH OF END BRACE TO JUNCTION


LENGTH OF GUSSET TO COLUMN
LENGTH OF GUSSET TO BEAM
THE WHITMORE WIDTH

SEISMIC PARAMETER (ASCE 7-05 11.4.4)


REDUNDANCY FACTOR (ASCE 7-05 12.3.4)

Lg = 12.023 in
2E=
15.6 in
2D=
17.2 in
W = 17.2 in

CBC 10 Chapter A (DSA or OSHPD) APPLY?

Yes

== >

( 1 in Gusset Plate with 8 in Length, 4 leg, 5/8" Fillet Weld at Brace.)


(Fill 3000 psi Solid Cement Grout in All Tube Bracings.)

THE BRACE DESIGN IS ADEQUATE.


ANALYSIS
CHECK LIMITING WIDTH THICKNESS RATIO FOR COMPRESSION ELEMENT, LOCAL BUCKLING (AISC 341-05 Tab. I-8-1)
[Satisfactory]
D / t = 0.044 Es / Fy
=
27.74 , for Pipe
Actual
>
0.5
(AISC 360-05, B4.2.d)
b / t = 0.64 (Es / Fy)
=
16.07 , for Tube
Where

Es =

29000

ksi

Fy =

46

ksi

CHECK LIMITING SLENDERNESS RATIO FOR V OR INVERTED-V CONFIGURATIONS (AISC 341-05 Sec. 13.2a)
K L / r = 80.4 [Satisfactory]
4.0 (Es / Fy)0.5 =
100.4
>
Where

K =

1.0

DETERMINE FACTORED DESIGN LOADS (CBC 10 1605.2 & ASCE 7-05 12.4.2.3)
Put = 0.9D - UQE - 0.2SDSD =

-182.75 kips (Tension)

Puc = 1.2D + L + UQE + 0.2SDSD =

213.75 kips (Compression, Governs)

CHECK DESIGN STRENGTH IN COMPRESSION (AISC 360-05 E3)


IcPn = IcAgFcr =
Where

439.36

Ic =
Fe =
Oc =

>

kips

Puc

[Satisfactory]
(Fy/Fe)

0.9
2

S E / (KL / r) =
(KL / r) (Fy / E)

44.237 ksi

0.5

Fcr =

(0.658

0.877 Fe =

)Fy =

29.77 kis, forOc 4.71


N/A

kis, forOc > 4.71

3.20

DETERMINE CONNECTION DESIGN FORCE (AISC 341-05 Sec. 13.3a)


Put = MIN(RyFyAg , Pmax) =
Where

403.75 kips (Tension)

Ry =

1.4

Pmax =

403.75

(AISC 341-05 Tab. I-6-1)


kips, (the estimated maximum earthquake force, that can be transferred
to the brace by the system.)

DETERMINE BEST FILLET WELD SIZE (AISC 360-05 Sec.J2.2b)


wMIN =
w=
5/8
in
>
( USE w =

0.625

in )
[Satisfactory]

<

0.25

in

wMAX = (I 0.6 Fu t) / (I 0.707 FEXX) = (0.75 x 0.6 x 58 ksi) t / (0.75 x 0.707 x 70 ksi)
= 1.1795 t =
0.74 in

(cont'd)
DETERMINE REQUIRED WELD LENGTH (AISC 360-05 Sec.J2.4)
L = Put / [(4) I Fw (0.707 w)]
= 403.75 / [(4) 0.75 (0.6x70)(0.707x5/8)] =
( USE

7.25
8

in
in )

CHECK SHEAR RUPTURE CAPACITY OF SLOTED BRACE


(AISC 360-05 Sec.J4.2)
IPn = I(0.6Fu)Anu =
522.00
kips
>
Put
I =
Where
0.75
[Satisfactory]
Fu =

58

ksi (AISC 13th Tab.2-3)

Anu = 4 t L = 4 x 0.625 x 8 =

20.00

in

DETERMINE REQUIRED THICKNESS OF GUSSET PLATE (AISC 360-05 Tab. J2.4)


tg =

in

( USE

in )

CHECK SHEAR RUPTURE CAPACITY OF GUSSET PLATE (AISC 360-05 Sec.J4.2)


IPn = I(0.6Fu)Anv = 417.60
I =
Where
0.75
Fu =

58

kips

>

Put

[Satisfactory]

16.00

in2

ksi (A36 Steel)

Anv = 2 tg L = 2 x 1 x 8 =
CHECK GUSSET BLOCK SHEAR CAPACITY (AISC 360-05 J4.3)
IRn = I(0.6Fu)Anv + IFyAgt =
417.60 + IFyAgt

>

GUSSET COMPRESSION CAPACITY (AISC 341-05 13.3c)


IcPn = IcFcrLwtg = 489.68 kips
<
1.1 Ry Pn

Put =
403.75
[Satisfactory]

Where

CHECK GUSSET TENSION YIELDING CAPACITY (AISC 360-05 D2 a)


ItPn = ItFyLwtg =
Where

558.50

kips

>

Put

Ic =
K =

0.9
1.2

[Unsatisfactory]
(SEAOC Vol.3 page 40)

rg = tg / (12)0.5 =

0.29 in

K Lg / rg < 200

[Satisfactory]

Oc =

(KL g / rg) (Fy / E)0.5 =

It =

0.9

[Satisfactory]

Fe =

114.58 ksi (AISC 360-05 Sec.E3)

Fy =

36

ksi (plate value)

Fcr =

31.564 ksi (AISC 360-05 Sec.E3)

Lw =

W=

17.2 in

(Gusset Stiffer Reqd, or Increase tg.)

CHECK SHEAR LAG FRACTURE OF BRACE (AISC 360-05 D.2 b)


IPn = IRt Fu Ae = 529.94
I =
Where
0.75
Fu =

58

kips

>

Put

[Satisfactory]

ksi (AISC 13th Tab.2-3)

B2+2BH / 4(B+H) = 3.00 , for Tube (AISC Tab. D3.1)


D / S = 2.55 , for Pipe (AISC 360 Tab. D3.1)
U = MIN( 1 - x / L , 0.9 ) =
0.63
,(AISC 360-05 Tab. D3.1.)
2
An = Ag - 2 (tg + 1/8) t =
14.99 in
x =

Ae =

U An =

9.37

in2

Rt =
1.3
(AISC 341-05 6.2)
Try Cover Plate
0
x
7
, at Each Sides.
(0 for no cover required)
x
xA
Region
0.5 An
HSS
Cover Plate
6

3.00
4.00

7.50
0.00
7.50

x = 22.49 / 7.50 =
3.00
U = MIN( 1 - x / L , 0.9 ) =
An = 14.99 + 0.00 =
14.99

22.49
0.00
22.49

Ae = U An =
Thus,

IPn = IRt Fu Ae = 529.94


Where

1.761

Fu =

58

kips

>

Put

9.37

in2

[Satisfactory]

ksi (plate value)

Technical References:
1. AISC 341-05: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, Nov. 16, 2005.
2. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.

0.63

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Special Concentrically Braced Frames Based on CBC/IBC & AISC
INPUT DATA & DESIGN SUMMARY
BEAM SECTION
BEAM DISTRIBUTED SERVICE LOADS

= > W14X605
D = 0.24 kips / ft
L=
L =

0.5
26
0

kips / ft
ft
No

Fy =

50

ksi

BEAM LENGTH
TOP FLANGE CONTINUOUSLY BRACED ?
BEAM YIELD STRESS

=>

A
178

d
20.9

tw
2.60

bf
17.40

tf
4.16

Sx
1040

Ix
10800

rx
7.79

ry
4.55

Zx
1320

k
4.76

THE BEAM DESIGN IS ADEQUATE.

DETERMINE FACTORED AXIAL LOAD ON THE BEAM (AISC 341-05 13.4a)


Pu = 0.5 (RyFyAg + 0.3IcPn) cos D =
Where

Ry =

1.4

D =

49.46

386.09 kips

(see brace sheet)


o

Fy =

46

ksi (see brace sheet)

Ag =

16.40

in2 (see brace sheet)

IcPn =

439.36

kips (see brace sheet)

CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)


bf / (2tf ) =
0.3 (Es / Fy)0.5 =
2.09
<

h / tw =

4.38

7.22

Es =

Where

[Satisfactory]

29000 ksi

3.14(Es/Fy)0.5(1-1.54Pu/IbPy) =

<

70.01

, for Pu/IbPy 0.125

(Es/Fy)0.5Max[1.49 , 1.12 (2.33-Pu/IbPy)] =


Where Ib =

[Satisfactory]

, Py = FyA =

0.9

N/A
8900

, for Pu/IbPy > 0.125


kips

DETERMINE UNBALANCED VERTICAL FORCE ON BEAM (AISC 341-05 13.4a)


Qb = (RyFyAg - 0.3IcPn) sin D =
702.45 kips (Vertical)
DETERMINE FACTORED MOMENT ON THE BEAM (CBC 10 1605.2 & ASCE 7-05 12.4.2.3)
Mnt = (1.2D + L) L 2/ 8 + Qb l/ 4 =

4632.48

ft-kips

DETERMINE UNBALANCED SEGMENT LENGTH ABOUT X - AND Y - AXES


Lx =

26

ft

Ly =

13

ft ( AISC Seismic Sec.13.4a ,lateral support at the intersection of chevron braces required.)

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


IcPn = IcFcrA =
Where

7123.39

Ic =
K =

>

kips

Pu

[Satisfactory]

0.9
1.0

MAX(KL x/rx, KL y/ry) =

<

40.05

200

[Satisfactory]

Oc =

(KL / r) (Fy / E)0.5 =

1.663

Fe =

S2 E / (KL / r)2 =

178.4 ksi (AISC 360-05 E3)

Fcr =

44.47

ksi (AISC 360-05 E3)

DETERMINE FLEXURAL DESIGN STRENGTH (AISC-AISC 360-05 F1)


Lb =

13.00

ft

L p = 1.76 ry (E / Fyf)0.5 =

Lr

1.95 r ts

E
0.7 F y

M p = Fy Zx =

F cr

Where

Jc
S x h0

0.5

Jc L b

S x h 0 r ts

231.67

ft

0.5

928.14 ksi

5.44

h0 = d - tf =

16.74

Cb =

, (AISC 360-05 F1)

1.30

ft-kips

1 0.078

r ts =[( Iy Cw) / Sx]


c =
1.00

ft

0.7 F y S x h 0
1 1 6.76

E
Jc

5500.0

C bS 2E
Lb

r ts

16.06

in

Iy
3680

G
11200

J
869

Cw
258000

(cont'd)

Mn

Ib Mn

Mp

5500

ft-kips, for L b @ [0 , L p]

MIN{Cb [Mp - (Mp - 0.75 Fy Sx) (Lb - Lp) / (Lr - Lp)] , Mp}

N/A

ft-kips, for L b @ (L p , L r]

MIN(Fcr Sx , Mp)

N/A

ft-kips, for L b @ (L r , Larger)

= 0.9 Mn =

4950

ft-kips

CHECK FLEXURAL CAPACITY (AISC 360-05 C2.1b)


Mu = B1Mnt =
Where

ft-kips
31755

Cm =
D=

(AISC 360-05 C2.1b)

1.0
1.0

IbMnx =

<

4689.50

Pe1 = S2EsIx / (KL x)2 =

kips

B1 = MAX[ Cm/(1 - D Pu/Pe1) , 1.0] =

4950

ft-kips

[Satisfactory]

1.012

CHECK INTERACTION CAPACITY (AISC 360-05 H1.1)


For Pu/IcPn0.2,

Pu / IcPn + 8 / 9 (Mux / IbMnx) =

N/A

For Pu/IcPn<0.2,

Pu / (2IcPn) + Mux / IbMnx =

0.97

<

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Special Concentrically Braced Frames Based on CBC/IBC & AISC
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION
COLUMN AXIAL SERVICE LOADS

= > W8X40
22
kips
D=
L=

29

kips

COLUMN AXIAL LOAD AT HORIZ. SEISMIC


UNBRACED COLUMN LENGTH

QE =
L =

18
14

kips, (ASCE 7-05 12.4.2.1)


ft

COLUMN YIELD STRESS (36 or 50)

Fy =

50

ksi

=>

A
11.7

d
8.3

tw
0.36

bf
8.07

Put = 0.9D - UQE - 0.2SDSD =

-2

Ix

rx

ry

Zx

3.53

2.05

40

0.95

THE COLUMN DESIGN IS ADEQUATE.

kips (Tension)
77

kips (Compression, Governs)

CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)


bf / (2tf ) =
0.3 (Es / Fy)0.5 = 7.22
7.21
<
Where
h / tw =

17.62

<

Es =

N/A

0.5

(Es/Fy) Max[1.49 , 1.12 (2.33-Pu/IbPy)] =


Where Ic =

[Satisfactory]

[Satisfactory]

29000 ksi

3.14(Es/Fy)0.5(1-1.54Pu/IbPy) =

, for Pu/IbPy < 0.125


58.89 , for Pu/IbPy > 0.125

0.9

Py = FyA =

585

kips

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


IcPn = IcFcrA =
Where

Ic =
K =

321.98

>

kips

[Satisfactory]

0.9
1.0

MAX(KL x/rx, KL y/ry) =


(KL / r) (Fy / E)

Fe =

S2 E / (KL / r)2 =
30.58

<

82.01
0.5

Oc =
Fcr =

Pu

3.405

200

[Satisfactory]

(AISC 360-05 E2-4, Pg 6-47)

42.557 ksi (AISC 360-05 E3)

ksi (AISC 360-05 E3)

CHECK AMPLIFIED SEISMIC LOAD EFFECTS FOR P u / f Pn > 0.4 (AISC 341-05 8.3)
Puc / I Pn =

0.24

<

Puc = 1.2D + L + :0QE + 0.2SDSD =


Where

:0 =

0.4

[Amplified Seismic Load Do Not Need to Checke]


95 kips

<

IcPn

Sx
35.5

146

DETERMINE FACTORED DESIGN LOADS (CBC 10 1605.2 & ASCE 7-05 12.4.2.3)
Puc = 1.2D + L + UQE + 0.2SDSD =
U=
Where
1

tf
0.56

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Special Concentrically Braced Frames Based on CBC/IBC & AISC
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION
COLUMN AXIAL SERVICE LOADS

= > HSS8X8X5/8
= > Tube
22
kips
D=
L=
29
kips
QE =
18
kips, (ASCE 7-05 12.4.2.1)
L =
14
ft

COLUMN AXIAL LOAD AT HORIZ. SEISMIC


UNBRACED COLUMN LENGTH
COLUMN YIELD STRESS (42 or 46)

Fy =

46

rmin

16.40

2.98

0.63

8.00

THE COLUMN DESIGN IS ADEQUATE.

ksi

ANALYSIS
CHECK LIMITING WIDTH THICKNESS RATIO FOR COMPRESSION ELEMENT, LOCAL BUCKLING (AISC 341-05 02 Tab. I-8-1)
[Satisfactory]
=
27.74 , for Pipe
D / t = 0.044 Es / Fy
Actual
>
0.5
(AISC 360-05, B4.2.d)
h / t = 0.64 (Es / Fy)
=
16.07 , for Tube
Where

Es =

29000

ksi

DETERMINE FACTORED DESIGN LOADS (CBC 10 1605.2 & ASCE 7-05 12.4.2.3)
Put = 0.9D - UQE - 0.2SDSD =

-2

Puc = 1.2D + L + UQE + 0.2SDSD =


U=
Where
1

kips (Tension)
77

kips (Compression, Governs)

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


IcPn = IcFcrA =
Where

Ic =
K =

548.56

kips

MAX(KL x/rx, KL y/ry) =


Oc =

(KL / r) (Fy / E)0.5 =

Fe =

S2 E / (KL / r)2 =

Fcr =

>

Pu

[Satisfactory]

0.9
1.0

37.17

56.31

<
200
[Satisfactory]

2.243

(AISC 360-05 E2-4, Pg 6-47)

90.279 ksi (AISC 360-05 E3)

ksi (AISC 360-05 E3)

CHECK AMPLIFIED SEISMIC LOAD EFFECTS FOR P u / f Pn > 0.4 (AISC 341-05 8.3)
Puc / I Pn =

0.14

<

Puc = 1.2D + L + :0QE + 0.2SDSD =


Where

:0 =

0.4

[Amplified Seismic Load Do Not Need to Checke]


95 kips

<

IcPn

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Buckling-Restrained Braced Frames Based on AISC 360-05 & AISC 341-05

DESIGN CRITERIA
1.

Bracing member self shall be composed of a structural steel core & a system that restrains the steel core from buckling.
The each end of brace to gusset plate may be standard bolted connections, modified bolted connections, or true pin
connections. Selecting bracing members are based on the tested & approved manufacture's lists.

2.

The lateral capacity of BRBF, selected bracing members with steel beams and columns, must also be checked by a special
loads combination of

3.

DL + LL + 2 x/1.5 (AISC 341-05, 16.2b, 16.5b & ASCE 7-05, 12.8.6).

For the connection of gusset plate to beam and column, the interface dimensions of and may not satisfy the basic
relationship of the Uniform Force Method: - tan = eb tan - ec. This software can determine gusset dimensions
based on geometry and can check the gusset interface weld capacities with moment loads.

INPUT DATA & DESIGN SUMMARY


BRACE CORE AXIAL YIELD STRENGTH
Pysc = 150 kips, SD
(from tested & approved manufacture's lists, AISC 341-05, 16.2a)
25

2=
2=

GUSSET DIMENSIONS

COLUMN SECTION
ORIENTATION =
BEAM SECTION
ORIENTATION =

=>

W12X96

x-x

, ec =

=>

W16X67

x-x

, eb =

24.0
10.1

in
in

6.35

in

8.15

in

ANGLE BETWEEN BRACE & COLUMN

THE CONNECTION DESIGN IS ADEQUATE.


( 1" Gusset Plate with 7/16" Fillet Weld, 2 leg x 24"
at Column Interface, 2 leg x 11" at Beam Interface. )

ANALYSIS
DETERMINE REQUIRED STRENGTH OF BRACING CONNECTION (AISC 341-05, 16.3a & 16.2d)
T = (1.1 / 1.5) Ry Pysc =

247.1

kips, ASD

=
=

1.20
1.44

, (AISC 341-05, 16.2d. May be verified by nonlinear time-history or analyses.)


, (AISC 341-05, 16.2d. May be verified by nonlinear time-history or analyses.)

Ry =

1.30

, (AISC 341-05, Table I-6-1)

Where

DETERMINE BEST FILLET WELD SIZE PER THICKNESS OF GUSSET & FLANGES (AISC 360-05 J2.2b)
> wMIN =
0.25
in
w=
7/16
in
< wMAX =
0.5625 in
[Satisfactory]
DETERMINE REQUIRED THICKNESS OF GUSSET PLATE
tg =

in

( USE tg =

DETERMINE CONNECTION INTERFACE FORCES ( AISC Manual 13th Edition, Page 13-10)
=
12.00 in
=
>
(eb + ) tan - ec =
3.05
5.07
in

in )

in

[the original Uniform Force Method not apply]


-2.55

D = tan2 + ( / )2 =
K' = ( tan + / ) =

in
0.396
4.5081

Ideal = (K' tan + K ( / )2 ) / D =


Ideal = (Ideal - K) / tan =

4.16
14.38

r = [(eb + Ideal)2 + (ec + Ideal)2] 0.5 =

24.86

Vc = (Ideal / r) T =

143.0

kips

Hc = (ec / r) T =

63.1

kips

Vb = (eb / r) T =

81.0

kips

Hb = (Ideal / r) T =

41.3

kips

Mc = Hc [ Ideal - ] =

12.5

Mb = Vb [ Ideal - ] =

-6.2

in

in

in

K = eb tan - ec =

ft-kips

ft-kips

CHECK WELD CAPACITY AT INTERFACES (AISC 360-05 J2.4 )


fVc = Vc / (4 0.707 w) =

10.37

ksi

fHc = Hc / (4 0.707 w) =

4.58

ksi

__

fMc = 3 Mc / (4 2 0.707 w) =

2.73

ksi

fVb = VB / (4 0.707 w) =

13.90

ksi

fHb = HB / (4 0.707 w) =

7.09

ksi

fMb = 3 Mb / (4 2 0.707 w) =
=
2.0

7.51

ksi

fv,c = [(fvc)2 + (fHc+ fMc)2] 0.5 =

12.68

ksi

fv,b = [(fvb)2 + (fHb + fMb)2] 0.5 =

20.16

ksi

<
<

Page 308 of 533


524

0.6 FEXX / =

21.00 ksi

[Satisfactory]

0.6 FEXX / =

21.00 ksi

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Buckling-Restrained Braced Frames Based on AISC 360-05 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
BEAM SECTION
BEAM DISTRIBUTED SERVICE LOADS

= > W16X67
D = 0.24 kips / ft

=>

A
20

L=
=

0.5
26
1

kips / ft
ft
Yes

BEAM AXIAL LOAD AT 2x/1.5 STORY DRIFT

P2x =

150

kips,ASD (AISC 341, 16.5b)

BEAM VERT LOAD AT 2x/1.5 STORY DRIFT

V2x =

25

kips

Fy =

50

ksi

BEAM LENGTH
TOP FLANGE CONTINUOUSLY BRACED ?

BEAM YIELD STRESS

d
16.3

tw
0.40

bf
10.20

tf
0.67

Sx
119

Ix
970

rx
6.96

ry
2.44

Zx
132

k
1.37

THE BEAM DESIGN IS ADEQUATE.

CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)


0.3 (Es / Fy)0.5 =
bf / (2tf ) =
7.67
<
Es =

Where
h / tw =

34.33

<

[Satisfactory]

29000 ksi

3.14(Es/Fy)0.5(1-1.54P2o/Py) =

N/A

, for P2o/Py < 0.125

1.12(Es/Fy)0.5(2.33-P2o/Py) =

N/A

, for P2o/Py > 0.125

Where o =

[Satisfactory]

< = does not apply for top flange continuously braced.


N/A

2.0

, (AISC 341-05, Table R3-1)

Py = FyA =

1000

kips

DETERMINE MOMENT ON THE BEAM


2

M = (D + L)

/ 8 + V2x / 4 =

225.03

ft-kips, ASD

DETERMINE UNBALANCED SEGMENT LENGTH ABOUT X - AND Y - AXES


=

26

ft

y=

13

ft

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


Pn/o = FcrA/o =
Where

370.76

o =
K =

2.0
1.0

MAX(K

x/rx,

(K

Fe =

2 E / (K

Fcr =

P2x

[Satisfactory]

, (AISC 341-05, Table R3-1)

y/ry)

c =

>

kips

200

[Satisfactory]

2.656

/ r)2 =

37.08

<

63.95

/ r) (Fy / E)0.5 =

69.979 ksi (AISC 360-05 E3)

ksi (AISC 360-05 E3)

DETERMINE FLEXURAL DESIGN STRENGTH (AISC-AISC 360-05 F1)


Lb =

13.00

ft

L p = 1.76 ry (E / Fyf)0.5 =

L r = 1.95 r ts

E
0.7 F y

M p = Fy Zx =

F cr =

8.62

Jc
S x h0

1+ 0.078

Lb
r ts
Where

1+ 1+ 6.76

550.0

C b 2E

h0 = d - tf =
1.30

0.7 F y S x h 0
E
Jc

26.24

ft

ft-kips
2

Jc

Lb
r ts

138.69 ksi

__

S x h0

r ts =[( Iy Cw)0.5/ Sx]0.5 =


c =
1.00
Cb =

ft

2.80

15.64

in

, (AISC 360-05 F1)

Page 309 of 533


524

Iy
119

G
11200

J
2.62

Cw
7300

(cont'd)

Mn

Mn/o =

275

Mp

N/A

ft-kips, for L b @ [0 , L p]

MIN{Cb [Mp - (Mp - 0.75 Fy Sx) (Lb - Lp) / (Lr - Lp)] , Mp}

550

ft-kips, for L b @ (L p , L r]

MIN(Fcr Sx , Mp)

N/A

ft-kips, for L b @ (L r , Larger)

ft-kips

CHECK FLEXURAL CAPACITY (AISC 360-05 C2.1b)


M = B1M =
Where

245.71
Pe1 = EsIx / (K
2

Cm =
=

1.0
1.6

x)

<

ft-kips
= 2852

kips

Mn/o =

275

ft-kips

4/3

[Satisfactory]

[Satisfactory]

(AISC 360-05 C2.1b)

B1 = MAX[ Cm/(1 - P2/Pe1) , 1.0] =

1.092

CHECK INTERACTION CAPACITY (AISC 360-05 H1.1)


For P2 o/Pn 0.2,

P2 o /Pn + 8 / 9 (M o / Mn) =

1.20

For P2 o/Pn<0.2,

P2 o / (2Pn) + M o / Mn =

N/A

__
Page 310 of 533
524

<

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Buckling-Restrained Braced Frames Based on AISC 360-05 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION
COLUMN AXIAL SERVICE LOADS

= > W12X96
D=
22
kips
L=

29

kips

COL AXIAL LOAD AT 2x/1.5 STORY DRIFT


UNBRACED COLUMN LENGTH

P2x =
=

100
14

kips, ASD (AISC 341, 16.5b)


ft

Fy =

50

ksi

COLUMN YIELD STRESS (36 or 50)

=>

A
28.2

d
12.7

tw
0.55

bf
12.20

Ix

rx

ry

Zx

833

5.43

3.09

147

THE COLUMN DESIGN IS ADEQUATE.

DETERMINE DESIGN LOAD (AISC 341-05, 16.2b & 16.5b)


P = D + L + P2x =
151
kips, ASD (Compression, Governs)
CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)
0.3 (Es / Fy)0.5 = 7.22
bf / (2tf ) =
6.78
<
Where
h / tw =

17.64

Es =

[Satisfactory]

29000 ksi

3.14(Es/Fy)0.5(1-1.54Po/Py) =

<

0.5

1.12(Es/Fy) (2.33-Po/Py) =
Where o =

[Satisfactory]

2.0

Py = Fy A =

N/A

, for Po/Py < 0.125

57.07

, for Po/Py > 0.125

, (AISC 341-05, Table R3-1)


1410

kips

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


Pn/o = FcrA/o =
Where

568.31

o =
K =
MAX(K

x/rx,

y/ry)

c =

(K

Fe =

2 E / (K

Fcr =

kips

2.0
1.0

[Satisfactory]

, (AISC 341-05, Table R3-1)


=

<

54.29

/ r) (Fy / E)0.5 =
40.31

>

/ r)2 =

2.254

tf
0.90

200

[Satisfactory]

(AISC 360-05 E2-4, Pg 6-47)

97.094 ksi (AISC 360-05 E3)

ksi (AISC 360-05 E3)

__
Page 311 of 533
524

Sx
131
k
1.50

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Special Plate Shear Wall Based on AISC 341-05 & AISC 360-05

DESIGN CRITERIA
1.

2.

3.

Design the boundary elements, columns & beams,


under gravity loads, DL & LL, without web plate exists.
(AISC 341-05, 17.4a)
Determine seismic forces of boundary elements with web
plate support. Use two layers steel plate strips, one layer angled
& another - , in 3D modeling software. Do not use Orthotropic
Finite Element modeling method.
Use this software to check the seismic capacities of SPSW
per AISC 341-05 Chapter 17.

INPUT DATA & DESIGN SUMMARY


VERTICAL BOUNDARY ELEMENT, VBE

=>

A
56.8

d
15.5

tw
0.89

Ix

rx

ry

W14X193

bf
15.70
Zx

2400
6.50
4.05
HORIZONTAL BOUNDARY ELEMENT, HBE

tf
1.44

Sx
310

355
=>

2.04
W21X50
tf
0.54

A
14.7

d
20.8

tw
0.38

bf
6.53

Ix
984

rx
8.18

ry
1.30

Zx
110

BOUNDARY STEEL YIELD STRESS

THE SPSW DESIGN IS ADEQUATE.


(Continuity VBE/column stiffeners 5/16 x 4.8
Sx
94.5

k
1.04

with 1/4" fillet weld to web & CP to flanges.


A doubler plate is not required. )

Iy
25

Fy =

50

ksi

WEB PLATE YIELD STRESS

Fy,WEB =

36

ksi

PDL =

50

kips

SEISMIC AXIAL LOAD ON VBE

PE =

50

kips

PLL =

85

kips

SEISMIC SHEAR FORCE ON WEB

VE =

897

kips

BEAM LENGTH BETWEEN COL. CENTERS

L=

30

ft

PARAMETER (ASCE 7-05 11.4.4)

SDS =

0.877

THICKNESS OF THE WEB PLATE

tw =

0.25

in

STORY HEIGHT

GRAVITY AXIAL LOAD ON VBE

ANALYSIS
CHECK PANEL ASPECT RATIO (AISC 341-05, 17.2b)
L/h=
2.0
>
0.8
<
2.5

h=

[Satisfactory]

CHECK WEB PLATES SHEAR STRENGTH (AISC 341-05, 17.2a)

= ATAN

1
4

t L
1+ w
2 Ac

h3
1+t wh
+
Ab 360 I cL
1

Vn = (0.42 Fy tw Lcf SIN 2) =


Where

0.9

Lcf =

345

36.3

1118.9 kips

VE
>
[Satisfactory]

in

CHECK VBE/COLUMN CAPACITY UNDER SEISMIC LOAD COMBINATION (AISC 341-05, 17.4a & 8.3)
Pu = (1.2 + SDS) PDL + f1 PLL + PE =
Where
Ic =

f1 =
2400

1
in4

cPn = cFcrA =
Where

0.00307 tw h4 / L =
[Satisfactory]

>

2212.03

c =
K =
MAX(K

x/rx,

y/ry)

29000

c =

(K

Fe =

2 E / (K

Fcr =

44.46

/ r) (Fy / E)0.5 =

[Satisfactory]

<

200

[Satisfactory]

1.846

/ r)2 =

144.8 ksi (AISC 360-05, E3)

ksi (AISC 360-05, E3)

<

2.5

(AISC 360-05, E3)

(AISC 360-05, E2-4, Pg 6-47)

__

43.27
0.11

0 =

Pu

in4 (AISC 341-05, 17.4g)

ksi

Puc = (1.2 + SDS) PDL + PLL + 0PE =


Where

>

kips

2238

0.9
1

Es =

Pu / Pn =

238.9 kips, (IBC 09, Eq. 16-5)


(IBC 09, 1605.2.1)

0.4

314

[Amplified Seismic Load Do Not Need to Checke]

kips

(AISC 341-05, Table R3-1)

Page 312 of 533


524

<

cPn

[Satisfactory]

15

ft

(Cont'd)

CHECK HBE/BEAM LOCAL BUCKLING LIMITATIONS (AISC 341-05, Tab. I-8-1)


bf / (2tf ) =

6.10

0.3 (Es / Fy)0.5 =

<

7.22

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


h / tw =

49.26

2.45 (Es / Fy)0.5 =

<

59.00

[Satisfactory]

[ 418 / (Fy)0.5 for FEMA Sec. 3.3.1.2]


CHECK VBE/COLUMN LOCAL BUCKING LIMITATIONS (AISC 341-05, Tab. I-8-1)
bf / (2tf ) =

5.45

0.3 (Es / Fy)0.5 =

<

7.22

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


3.14(Es/Fy)0.5(1-1.54Ca) =
h / tw =

64.74 , for Ca = Pu/bPy

0.125

[ 520 / (Fy)0.5(1-1.54Pu/bPy) for AISC Seismic 97, Tab. I-9-1]

<

12.83

1.12(Es/Fy)0.5MAX(1.49, 2.33 - Ca) =

N/A

, for Ca = Pu/bPy > 0.125

0.5
0.5
{ MAX[ 191 / (Fy) (2.33-Pu/bPy) , 253 / (Fy) ] for AISC Seismic 97, Tab. I-9-1}

Where b =

[Satisfactory]

0.9

, Py = FyA =

2840

kips

CHECK BEAM - COLUMN RATIO REQUIREMENT (AISC 341-05, 17.4a & 9.6)
Mpc* / (Mpb* ) =
Where

4.89

>

1.00

[Satisfactory]

Mpc* = Nc Zc (Fyc - Pu / Ag ) + Vcol (db / 2) =


Nc =

Mpb* = Nb MB + Vbm (dc / 2) =


Nb =

2710

2710

ft-kips

, (if only one column below, input 1)

555

555

ft-kips

, (if double side connected to SPSW, input 2)

MB = CprRyFyb Zb =

555

ft-kips

Ry =

1.1

(AISC 341-05 Tab. I-6-1)

Cpr =

1.1

(AISC 341-05 Sec. 9.6 & AISC 358-05 Sec. 2.4.3)

CHECK CONTINUITY PLATE REQUIREMENT (AISC 341-05, 17.4b & AISC 358-05, 2.4.4)
tcf = MIN{ bbf / 6 , 0.4[1.8bbf tbf (FybRyb) / (FybRyb)] 0.5 }=

1.00
in
<
actual tcf
(The continuity plates may not be required.)

tst = tbf for interior connection, or (tbf /2) for exterior connection =
bst =

4.8

cPn,st = cFcr A =
Where

0.56 (E / Fyst )0.5 tst =

<

in

0.27

in,

4.97

in, (AISC 360-05 Sec. G3.3)


[Satisfactory]

USE

0.31

in, ( 5/16 in )

214.0 kips

c =

0.9

K =

0.75

(AISC 360-05, E1)

hst = dc - 2k =

11.42

K hst / rst < 200

(AISC 360, E2)

in

I = tst (2bst + twc) 3 / 12 =

26

in4

Fe = 2 E / (K hst / rst)2 =

A = 2bsttst + 25(twc) 2 =

in2

c = (K hst / rst) (Fy / E)0.5 =

0.5

rst = ( I / A )

Fyst =

(Fy/Fe)

1.98 in
36

Fcr =

kips, stiff. yield stress

Pu,st = Ryb Fyb bfb tfb =

192.1 kips

The best fillet weld size (AISC 360-05, J2.2b)


> wMIN =
w=
1/4
in
< wMAX =

<

cPn,st

0.1875

in

0.25

in

(0.658

[Satisfactory]

15279 ksi, (AISC 360, E3)


0.15

)Fy =

0.877 Fe =

, c

35.96
N/A

4.71

kis, for c > 4.71

[Satisfactory]

[Satisfactory]
The required weld length between continuity plates and column web (AISC 360-05, J2.2b)
Lw = 0.6tstLnstFy / [(2) Fw (0.707 w)]
Where

= 0.6 x (0.3125 x 8.4) x 36 / [(2) 0.75 (0.6x70)(0.707x1/4)] =

Lnet = dc - 2(kc + 1.5) =

<

8.4

3.61

in

2(Lnet -0.5) [Satisfactory]

(Use complete joint penetration groove welds between continuity plates & column flanges.)
CHECK PANEL ZONE THICKNESS REQUIREMENT (AISC 341-05, 17.4f & 9.3)
tReqD = MAX (t1, t2) =

0.57

in

t1 = Cy Mc (h - db ) / [0.9 (0.6) Fyc Ryc dc (db - tfb) h] =


Where

Cy = Sb / (Cpr Zb) =

0.91

Sb = 2Ib / db =

95

Ib = Ix =

984

Mc = Mpb* =

0.89

in

in2

in

555

ft-kips

__

t2 = (dz + wz ) / 90 = (db -2tst + dc - 2k) / 90 =


Since twc =
not required.

0.57

in

>

0.35

in

tReqD ,

a doubler plate is

Technical References:
1. AISC 341-05: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, Nov. 16, 2005.
2. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.
3. AISC 358-05: "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications",
American Institute of Steel Construction, Dec 13, 2005.

Page 313 of 533


524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Eccentrically Braced Frames Based on IBC 09 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
LINK SECTION

=>

MAX SERVICE LOADS AT LINK END

VDL =

=>

1.8

kips

PDL =

7.4

kips

MDL =

14.4

ft-kips

tw

bf

tf

Sx

42.1

19.5

0.73

11.20

1.32

282

Ix

rx

ry

Zx

2750

8.08

2.72

322

k
1.72

VLL =

1.3

kips

PLL =

5.3

kips

THE LINK DESIGN IS ADEQUATE.

MLL =

9.6

ft-kips

( USE 3/4 x 4-7/8 @ 24 in o.c. INTERMEDIATE

VE =

84

kips (ASCE 7-05, 12.4.2.1)

& END STIFFENERS WITH 5/16" FILLET WELD.)

PE =

5.5

kips

ME =
e=

168
4

ft-kips
ft

Fy =
=
SDS =
L=
h=
=

50
1.19
1
30
12.5
0.7

ksi

MAX HORIZ. SEISMIC LOADS AT LINK END

LINK LENGTH
LINK YIELD STRESS
REDUNDANCY FACTOR
SEISMIC PARAMETER
BEAM LENGTH BETWEEN COL. CENTERS
STORY HEIGHT
MAXIMUM INELASTIC STORY DRIFT

W18X143

(ASCE 7-05, 11.4.4)


ft (including link)
ft
in (ASCE 7-05, 12.8.6)

DETERMINE FACTORED DESIGN LOADS AT LINK END (IBC 09 1605.2 & ASCE 7-05 12.4.2.3)
Vu = (1.2 + 0.2SDS)VDL + f1VLL + VE =

103.13 kips

Pu = (1.2 + 0.2SDS)PDL + f1PLL + PE =

19.56

Mu = (1.2 + 0.2SDS)MDL + f1MLL + ME =

224.88 ft-kips

kips

f1 =
Where
0.5
CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)
bf / (2tf ) =

4.24

0.3 (Es / Fy)0.5 =

<

7.22

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


Where

Es =

29000 ksi

3.14(Es/Fy)0.5(1-1.54Pu/bPy) =
h / tw =

74.42 , for Pu/bPy < 0.125

[ 520 / (Fy)0.5(1-1.54Pu/bPy) for AISC Seismic 97, Tab. I-9-1]

<

22.00

(Es/Fy)0.5 MAX[1.49, 1.12(2.33 - Ca)] =

N/A

, for Pu/bPy > 0.125

{ MAX[ 191 / (Fy)0.5(2.33-Pu/bPy) , 253 / (Fy)0.5] for AISC Seismic 97, Tab. I-9-1}
[Satisfactory]
Where b =
CHECK SHEAR CAPACITY (AISC 341-05, Sec. 15.2b)
Vn = MIN(Vp, 2Mp/e) =
Where

332.3 kips

0.9

0.9

, Py = Fy A =

>

Vu

2105

kips

[Satisfactory]

Aw = (d - 2tf)tw =

(Ignored axial force effect since Pu < 0.15 Py = 0.15 Fy Ag, AISC 341-05, 15.2)
in2
12.31

Vp = 0.6FyAw =

369.2

kips

Mp = F y Z =
1341.7 ft-kips
CHECK FLEXURAL CAPACITY (AISC 360-05 F1)
b Mp =

1207.5

>

Mu

[Satisfactory]

Where b =
0.9
CHECK ADDITIONAL SHEAR CAPACITY REQUIREMENT FOR Pu>0.15Py ONLY (AISC 341-05, 15.2b)
Vna = MIN(Vpa, 2Mpa/e) =
Where

>

332.3 kips

Vu

0.9

Vpa = Vp[1 - (Pu/Py)2 ]0.5 =

369.2

kips

Mpa = 1.18 Mp(1 - Pu/Py) =


1568.5 ft-kips
CHECK ADDITIONAL LINK LENGTH REQUIREMENT FOR Pu>0.15Py ONLY (AISC 341-05, 15.2b)
e

< = DOES NOT APPLY.

[Satisfactory]

<
[Satisfactory]

__

< = DOES NOT APPLY.

[1.15 - 0.5' (Aw/Ag)](1.6Mp/Vp) =

N/A

ft, for ' (Aw/Ag) > 0.3

(1.6Mp/Vp) =

5.81

ft, for ' (Aw/Ag) < 0.3

Where ' = Pu / Vu =
Aw / Ag =

0.19

0.29

Page 314 of 533


524

(cont'd)
CHECK LINK ROTATION ANGLE LIMITATION (AISC 341-05, 15.2c)
p = L / (h e) =
Where

0.04

rad

p,allowable =

<

0.080

rad

[Satisfactory]

p,allowable == 0.08 rad for e < 1.6Mp/Vp;


= 0.02 rad for e > 2.6Mp/Vp;
= linear interpolation [0.02, 0.08] by e value.
1.6Mp/Vp =

5.81

ft,

2.6Mp/Vp =

9.45

ft

CHECK LINK STIFFENER REQUIREMENT (AISC 341-05, 15.3)


bst = (bf - 2tw) /2 =

4.87

in

tst = MAX (0.75 tw , 3/8 ) =

0.548

in

USE 9/16 x 4-7/8 END STIFFENERS AT EACH SIDE.


s = see table following =
Provide 1 stiffeners to give s =
Where

30.0
24.0

in
in

1.6 Mp / Vp =

5.81

ft

2.6 Mp / Vp =

9.45

ft
ft

5.0 Mp / Vp =

18.17

p =

0.04

rad

e=
d=

4
19.5

ft
in

tst = MAX (tw , 3/8 ) =

0.730

in

USE 3/4 x 4-7/8 @ 24 in o.c. INTERMEDIATE


STIFFENERS AT EACH SIDE.
e
[0~1.6Mp/Vp]

p
(0.02 ~ 0.08)

[0 ~ 0.02]
52tw-d/5

(1.6Mp/Vp~2.6Mp/Vp] MIN(52tw-d/5 , bf)


(2.6Mp/Vp~5Mp/Vp)
[5.0Mp/Vp~Greater]

0.08

178tw/3-d/5-1100ptw/3

1.5bf
Not ReqD

Min(178tw/3-d/5-1100ptw/3 , 1.5bf)

30tw-d/5
MIN(30tw-d/5 , 1.5bf)

1.5bf

1.5bf

Not ReqD

Not ReqD

The best fillet weld size (AISC 360-05 Sec.J2.2b)


> wMIN =
w=
5/16
in
< wMAX =

0.1875 in
0.4375 in

[Satisfactory]
The required weld length between A36 stiffener and web (AISC 360-05 Sec.J2.4)
Lw = AstFy / [(2) Fw (0.707 w)]

= (9/16 x 4-7/8) x 36 / [(2) 0.75 (0.6x70)(0.707x5/16)] =

5.01

<

in
(d - 2k), [Satisfactory]

The required weld length between A36 stiffener and flange (AISC 360-05 Sec.J2.4)
Lf = 0.25AstFy / [(2) Fw (0.707 w)]

= 0.25(9/16 x 4-7/8) x 36 / [(2) 0.75 (0.6x70)(0.707x5/16)] =

<

1.25

CHECK COMBINED LINK CAPACITY (AISC 360-05 Sec.H.1)


f = Pu,link / (2Af) + Mu,link / Zf =
Where

<

35.3

Pu,link = Pu =

70.0

Mu,link = Vp (e/2) =

738.5

ft-kips

Zf = (d - tf) bf tf =

268.8

in3

= Vn / Vu =

3.58

Af = bf tf =

14.78

Fy

[Satisfactory]

kips

in2

Technical References:
1. AISC 341-05: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, Nov. 16, 2005.
2. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.

__
Page 315 of 533
524

in

(bst - k), [Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Eccentrically Braced Frames Based on IBC 09 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
HSS10X10X5/8

BRACE SECTION (Tube or Pipe)

=>

MAX SERVICE LOADS

PDL =

11.8

kips

PLL =

8.3

kips

Tube

rmin

21.00

3.80

0.58

10.00

11
ft
UNBRACED LENGTH OF THE BRACE
Lb =
(SEE LINK DESIGN SPREADSHEET FOR BALANCE OF INPUT DATA)

THE BRACE DESIGN IS ADEQUATE.


REQUIRED CONNECTION = >

( 5/8 in Gusset Plate with 23 in Length, 4 leg, 5/16 in Fillet Weld.)

DETERMINE LIMITING WIDTH THICKNESS RATIO FOR COMPRESSION ELEMENT, LOCAL BUCKLING (AISC 341-05 Tab. I-8-1)
D / t = 0.044 Es / Fy
h / t = 1.12 (Es / Fy)
Where

0.5

Fy =

46

ksi

Es =

29000

ksi

27.74 , for Pipe

28.12 , for Tube

>

Actual

[Satisfactory]

DETERMINE FACTORED DESIGN LOADS (AISC 341-05 Sec.15.6)


Pu = (1.2 + 0.2SDS)PDL + f1PLL + PE =
Where

629.9

kips

PE = 1.25 Ry [Vn L Lb / (L-e) h] =


Ry =

1.3

609.2

kips

(1.4 for Pipe.)

DETERMINE DESIGN STRENGTH IN COMPRESSION (AISC 360-05 E3)


cPn = cAgFcr =

757.24

c =

0.85

Fe =

2 E / (K

c =
K =

(K

>

kips
/ r)2 =
0.5

/ r) (Fy / E)
1.0

Pu

237.8 ksi
=

1.38

[Satisfactory]

Fcr =

(0.658

(Fy/Fe)

0.877 Fe =

)Fy =

42.42 kis, for c


N/A

4.71

kis, for c > 4.71

DETERMINE CONNECTION DESIGN FORCE


Put = Pu =

629.91

kips (Tension)

DETERMINE BEST FILLET WELD SIZE (AISC 360-05 Sec.J2.2b)


> wMIN =
0.1875 in
w=
5/16
in
< wMAX =
0.4375 in
[Satisfactory]
DETERMINE REQUIRED WELD LENGTH (AISC 360-05 Sec.J2.4)
L = Put / [(4) Fw (0.707 w)]
= 629.9 / [(4) 0.75 (0.6x70)(0.707x5/16)] =

22.63 in
( USE
23
in )
CHECK DESIGN SHEAR RUPTURE CAPACITY OF SLOTTED BRACE
(AISC 360-05 Sec.J4.2)
>
Put
Rn = (0.6Fu)Anu = 1395.10 kips
=
Where
0.75
[Satisfactory]
Fu =

58

ksi (AISC 13th Tab.2-3)

in2
53.45
Anu = 4 t L = 4 x 0.581 x 23 =
DETERMINE REQUIRED THICKNESS OF GUSSET PLATE (AISC 360-05 Tab. J2.4)
5/8
in
tg =
CHECK SHEAR RUPTURE CAPACITY OF GUSSET PLATE (AISC 360-05 J4.2)
Rn = (0.6Fu)Anv = 750.38
=
Where
0.75
Fu =

58

kips

>

t =
U =

0.75
1

An = A - 2 t tg =

[Satisfactory]

28.75

in2

Put

THE GUSSET BLOCK SHEAR CAPACITY (AISC 360-05 J4.3)


Rn = (0.6Fu)Anv + FyAgt =
750.38 + FyAgt

ksi (plate value)

Anv = 2 tg L = 2 x 5/8 x 23 =
CHECK TENSION AT SLOTTED BRACE (AISC 360-05 D.2 b)
tPn = tRyFuUAn =
1146.48 kips
>
Where

Put

__
[Satisfactory]
(LRFD Sec.B3.2d)
2
20.274 in

Page 316 of 533


524

>
Put =
[Satisfactory]

629.91

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Eccentrically Braced Frames Based on IBC 09 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
MAX SERVICE LOADS AT OUTSIDE OF LINK

VDL =

6.8

kips

PDL =

kips

MDL =

17

ft-kips

VLL =

4.8

kips

PLL =

0.7

kips

MLL =

11.3

ft-kips

VE =

8.7

kips (ASCE 7-05 12.4.2.1)

PE =

100

kips

ME =

100

ft-kips

SEISMIC LOADS AT OUTSIDE OF LINK

THE BEAM DESIGN IS ADEQUATE.

(SEE LINK DESIGN SPREADSHEET FOR BALANCE OF INPUT DATA)

DETERMINE FACTORED DESIGN LOADS AT SECTION OF LINK AND BEAM (AISC 360-05 Sec. 15.6b & ASCE 7-05 12.4.2.3)
Vu = (1.2 + 0.2SDS)VDL + f1VLL + VE =

67.0

kips

Pu = (1.2 + 0.2SDS)PDL + f1PLL + PE =

537.9

kips

Mu = (1.2 + 0.2SDS)MDL + f1MLL + ME =

923.0

ft-kips

f1

Where

0.5

Ry =

1.1

Vn =

369.2

(AISC 341-05 Tab. I-6-1)


kips (from link design)

Mn = Vn e / 2 =

738.47 ft-kips

VE = (1.1Ry Vn / VE , link) VE =

46.3

kips

PE = 1.1Ry Vn L / 2h =

536.1

kips

ME = 1.1Ry Mn =

893.5

ft-kips

CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)


bf / (2tf ) =

0.3 (Es / Fy)0.5 =

<

4.24

7.22

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


Where

Es =

29000 ksi

3.14(Es/Fy)0.5(1-1.54Pu/bPy) =
h / tw =

N/A

, for Pu/bPy < 0.125

[ 520 / (Fy)0.5(1-1.54Pu/bPy) for AISC Seismic 97, Tab. I-9-1]

<

22.00

(Es/Fy)0.5 MAX[1.49, 1.12(2.33 - Ca)] =

55.19 , for Pu/bPy > 0.125

0.5

{ MAX[ 191 / (Fy) (2.33-Pu/bPy) , 253 / (Fy)0.5] for AISC Seismic 97, Tab. I-9-1}
Where b =

[Satisfactory]

0.9

, Py = FyA =

2105

kips

CHECK UNBALANCED SEGMENT LENGTH


1

= (L - e - dc) / 2 =

12.38

ft, (top & bottom flange bracing with a design strength greater than below will be provided

Brace Load : Pb,link = 0.06Ry Fy bf tf =


2

/2=

6.19

48.8 kips, [AISC Seismic Sec.15.5]

ft, ( lateral supported at middle of beam outside of link with following design strength.)

Brace Load : Pb,mid = 0.02Fy bf tf =

14.8 kips, [AISC 341-05 Sec.15.6.(2)]

Mb, mid =0.02Fy bf tf d =

24.0 ft-kips, [AISC 341-05 Sec.15.6.(2)]

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


cPn = cFcrA =
Where

1694.11

c =
K =
MAX(K

kips

>

Pu

[Satisfactory]

= 27.34

<

200

[Satisfactory]

0.85
1.0
1/rx,

at each end of the link segment.)

2/ry)

__

c =

0.361

Fcr =

47.34 ksi

Page 317 of 533


524

(cont'd)
DETERMINE FLEXURAL DESIGN STRENGTH (AISC-AISC 360-05 F1)
Lb =

6.19

ft

L p = 1.76 ry (E / Fyf)0.5 =

9.60

L r = ry X1 [1 + (1 + X2 FL2 )0.5 ]0.5 / FL =

ft
35.27

M p = MIN( Fy Zx , 1.5 Fy Sx) =

1341.7 ft-kips

M r = FL Sx =

ft-kips

940.0

M cr = Cb Sx ry X1 (2 + X12 X2 ry2 / Lb2)0.5 / Lb =


Where

ft-kips

4036.3

Iy

tf

ry

Sx

X 2 = 4 Cw [Sx / (G J)]2 / Iy =

0.0006

42.1

311

1.32

2.72

282

10.00

ksi

FL = MIN( Fyf - Fr , Fyw) =

b Mn

17113

X 1 = (0.5 E G J A)0.5 / Sx =
Fr =

Mn

ft

40.00

ksi

Cw

Zx

29000

11200

19.2

25700

322.0

Cb =

1.30
Mp

1341.7 ft-kips, for L b @ [0 , L p]

MIN{Cb [Mp - (Mp - Mr) (Lb - Lp) / (Lr - Lp)] , Mp}

N/A

ft-kips, for L b @ (L p , L r]

MIN(Mcr , Mp)

N/A

ft-kips, for L b @ (L r , Larger)

= 0.9 Mn =

, (AISC 360-05 F1)

1208

ft-kips

CHECK FLEXURAL CAPACITY (AISC 360-05 C2.1b)


Mux = B1Mu =
Where

923.00

Pe1 = 2EsI x / (K
Cm =

x)

0.6

bMnx = Min(Ry bFyZ, bMn) =

<

ft-kips
= 35645

kips

[Satisfactory]

(AISC 360-05 C2.1b)

B1 = Cm/(1 - Pu/Pe1) =

Where

b =

0.9

1.000

CHECK INTERACTION CAPACITY (AISC 360-05 H1.1)


For Pu/cPn>0.2,

Pu / cPn + 8 / 9 (Mux / bMnx) =

1.00

For Pu/cPn<0.2,

Pu / (2cPn) + Mux / bMnx =

N/A

<

__
Page 318 of 533
524

[Satisfactory]

1208

ft-kips

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Eccentrically Braced Frames Based on IBC 09 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
W14X145

=>

COLUMN SECTION

=>

COLUMN AXIAL SERVICE LOADS

PDL =

151

kips

PLL =
n=

46
4

kips

NUMBER OF STORIES
COLUMN YIELD STRESS (36 or 50)

Fy =

50

ksi

tw

bf

tf

Sx

42.7

14.8

0.68

15.50

1.09

232

Ix
1710

rx
6.33

ry
3.98

Zx
260

k
1.69

THE COLUMN DESIGN IS ADEQUATE.


UNBRACED COLUMN LENGTH

=h=

14

ft

DETERMINE COLUMN AXIAL SEISMIC LOAD (AISC 341-05 Sec. 15.8)


PE = (n - 1) 1.1 Ry Vn =

1340.3 kips

DETERMINE FACTORED DESIGN LOADS (AISC 360-05 Sec. 15.6b & ASCE 7-05 12.4.2.3)
Pu,t = (0.9 - 0.2SSD ) PDL - PE =

-1235 kips (Tension)

Pu,c = (1.2 + 0.2SDS)PDL + f1PLL + PE =


Where

f1 =

0.5

1575

kips (Compression)

(IBC 1605.2)

CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)


bf / (2tf ) =

7.11

0.3 (Es / Fy)0.5 =

<

7.22

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


Where

Es =

29000 ksi

3.14(Es/Fy)0.5(1-1.54Pu/bPy) =
h / tw =

N/A

, for Pu/bPy < 0.125

0.5

<

16.79

[ 520 / (Fy) (1-1.54Pu/bPy) for AISC Seismic 97, Tab. I-9-1]


(Es/Fy)0.5 MAX[1.49, 1.12(2.33 - Ca)] =

40.74 , for Pu/bPy > 0.125

{ MAX[ 191 / (Fy)0.5(2.33-Pu/bPy) , 253 / (Fy)0.5] for AISC Seismic 97, Tab. I-9-1}
Where c =

[Satisfactory]

0.9

Py = Fy A =

2135

kips

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


cPn = cFcrA =
Where

1593.27

c =
K =
MAX(K

kips

>

Pu

[Satisfactory]

0.85
1.0
x/rx,

y/ry)

42.19

c =

0.558

Fcr =

43.90 ksi

<

200

[Satisfactory]

__
Page 319 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Eccentrically Braced Frames Based on CBC 07 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
LINK SECTION

=>

MAX SERVICE LOADS AT LINK END

VDL =

=>

1.8

kips

PDL =

7.4

kips

MDL =

14.4

ft-kips

tw

bf

tf

Sx

42.1

19.5

0.73

11.20

1.32

282

Ix

rx

ry

Zx

2750

8.08

2.72

322

k
1.72

VLL =

1.3

kips

PLL =

5.3

kips

THE LINK DESIGN IS ADEQUATE.

MLL =

9.6

ft-kips

( USE 3/4 x 4-7/8 @ 24 in o.c. INTERMEDIATE

VE =

84

kips (ASCE 7-05, 12.4.2.1)

& END STIFFENERS WITH 5/16" FILLET WELD.)

PE =

5.5

kips

ME =
e=

168
4

ft-kips
ft

Fy =
=
SDS =
L=
h=
=

50
1.19
1
30
12.5
0.7

ksi

MAX HORIZ. SEISMIC LOADS AT LINK END

LINK LENGTH
LINK YIELD STRESS
REDUNDANCY FACTOR
SEISMIC PARAMETER
BEAM LENGTH BETWEEN COL. CENTERS
STORY HEIGHT
MAXIMUM INELASTIC STORY DRIFT

W18X143

(ASCE 7-05, 11.4.4)


ft (including link)
ft
in (ASCE 7-05, 12.8.6)

DETERMINE FACTORED DESIGN LOADS AT LINK END (CBC 07 1605.2 & ASCE 7-05 12.4.2.3)
Vu = (1.2 + 0.2SDS)VDL + f1VLL + VE =

103.13 kips

Pu = (1.2 + 0.2SDS)PDL + f1PLL + PE =

19.56

Mu = (1.2 + 0.2SDS)MDL + f1MLL + ME =

224.88 ft-kips

kips

f1 =
Where
0.5
CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)
bf / (2tf ) =

4.24

0.3 (Es / Fy)0.5 =

<

7.22

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


Where

Es =

29000 ksi

3.14(Es/Fy)0.5(1-1.54Pu/bPy) =
h / tw =

74.42 , for Pu/bPy < 0.125

[ 520 / (Fy)0.5(1-1.54Pu/bPy) for AISC Seismic 97, Tab. I-9-1]

<

22.00

(Es/Fy)0.5 MAX[1.49, 1.12(2.33 - Ca)] =

N/A

, for Pu/bPy > 0.125

{ MAX[ 191 / (Fy)0.5(2.33-Pu/bPy) , 253 / (Fy)0.5] for AISC Seismic 97, Tab. I-9-1}
[Satisfactory]
Where b =
CHECK SHEAR CAPACITY (AISC 341-05, Sec. 15.2b)
Vn = MIN(Vp, 2Mp/e) =
Where

332.3 kips

0.9

0.9

, Py = Fy A =

>

Vu

2105

kips

[Satisfactory]

Aw = (d - 2tf)tw =

(Ignored axial force effect since Pu < 0.15 Py = 0.15 Fy Ag, AISC 341-05, 15.2)
in2
12.31

Vp = 0.6FyAw =

369.2

kips

Mp = F y Z =
1341.7 ft-kips
CHECK FLEXURAL CAPACITY (AISC 360-05 F1)
b Mp =

1207.5

>

Mu

[Satisfactory]

Where b =
0.9
CHECK ADDITIONAL SHEAR CAPACITY REQUIREMENT FOR Pu>0.15Py ONLY (AISC 341-05, 15.2b)
Vna = MIN(Vpa, 2Mpa/e) =
Where

>

332.3 kips

Vu

0.9

Vpa = Vp[1 - (Pu/Py)2 ]0.5 =

369.2

kips

Mpa = 1.18 Mp(1 - Pu/Py) =


1568.5 ft-kips
CHECK ADDITIONAL LINK LENGTH REQUIREMENT FOR Pu>0.15Py ONLY (AISC 341-05, 15.2b)
e

< = DOES NOT APPLY.

[Satisfactory]

<
[Satisfactory]

__

< = DOES NOT APPLY.

[1.15 - 0.5' (Aw/Ag)](1.6Mp/Vp) =

N/A

ft, for ' (Aw/Ag) > 0.3

(1.6Mp/Vp) =

5.81

ft, for ' (Aw/Ag) < 0.3

Where ' = Pu / Vu =
Aw / Ag =

0.19

0.29

Page 320 of 533


524

(cont'd)
CHECK LINK ROTATION ANGLE LIMITATION (AISC 341-05, 15.2c)
p = L / (h e) =
Where

0.04

rad

p,allowable =

<

0.080

rad

[Satisfactory]

p,allowable == 0.08 rad for e < 1.6Mp/Vp;


= 0.02 rad for e > 2.6Mp/Vp;
= linear interpolation [0.02, 0.08] by e value.
1.6Mp/Vp =

5.81

ft,

2.6Mp/Vp =

9.45

ft

CHECK LINK STIFFENER REQUIREMENT (AISC 341-05, 15.3)


bst = (bf - 2tw) /2 =

4.87

in

tst = MAX (0.75 tw , 3/8 ) =

0.548

in

USE 9/16 x 4-7/8 END STIFFENERS AT EACH SIDE.


s = see table following =
Provide 1 stiffeners to give s =
Where

30.0
24.0

in
in

1.6 Mp / Vp =

5.81

ft

2.6 Mp / Vp =

9.45

ft
ft

5.0 Mp / Vp =

18.17

p =

0.04

rad

e=
d=

4
19.5

ft
in

tst = MAX (tw , 3/8 ) =

0.730

in

USE 3/4 x 4-7/8 @ 24 in o.c. INTERMEDIATE


STIFFENERS AT EACH SIDE.
e
[0~1.6Mp/Vp]

p
(0.02 ~ 0.08)

[0 ~ 0.02]
52tw-d/5

(1.6Mp/Vp~2.6Mp/Vp] MIN(52tw-d/5 , bf)


(2.6Mp/Vp~5Mp/Vp)
[5.0Mp/Vp~Greater]

0.08

178tw/3-d/5-1100ptw/3

1.5bf
Not ReqD

Min(178tw/3-d/5-1100ptw/3 , 1.5bf)

30tw-d/5
MIN(30tw-d/5 , 1.5bf)

1.5bf

1.5bf

Not ReqD

Not ReqD

The best fillet weld size (AISC 360-05 Sec.J2.2b)


> wMIN =
w=
5/16
in
< wMAX =

0.1875 in
0.4375 in

[Satisfactory]
The required weld length between A36 stiffener and web (AISC 360-05 Sec.J2.4)
Lw = AstFy / [(2) Fw (0.707 w)]

= (9/16 x 4-7/8) x 36 / [(2) 0.75 (0.6x70)(0.707x5/16)] =

5.01

<

in
(d - 2k), [Satisfactory]

The required weld length between A36 stiffener and flange (AISC 360-05 Sec.J2.4)
Lf = 0.25AstFy / [(2) Fw (0.707 w)]

= 0.25(9/16 x 4-7/8) x 36 / [(2) 0.75 (0.6x70)(0.707x5/16)] =

<

1.25

CHECK COMBINED LINK CAPACITY (AISC 360-05 Sec.H.1)


f = Pu,link / (2Af) + Mu,link / Zf =
Where

<

35.3

Pu,link = Pu =

70.0

Mu,link = Vp (e/2) =

738.5

ft-kips

Zf = (d - tf) bf tf =

268.8

in3

= Vn / Vu =

3.58

Af = bf tf =

14.78

Fy

[Satisfactory]

kips

in2

Technical References:
1. AISC 341-05: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, Nov. 16, 2005.
2. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.

__
Page 321 of 533
524

in

(bst - k), [Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Eccentrically Braced Frames Based on CBC 07 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
HSS10X10X5/8

BRACE SECTION (Tube or Pipe)

=>

MAX SERVICE LOADS

PDL =

11.8

kips

PLL =

8.3

kips

Tube

rmin

21.00

3.80

0.58

10.00

11
ft
UNBRACED LENGTH OF THE BRACE
Lb =
(SEE LINK DESIGN SPREADSHEET FOR BALANCE OF INPUT DATA)

THE BRACE DESIGN IS ADEQUATE.


REQUIRED CONNECTION = >

( 5/8 in Gusset Plate with 23 in Length, 4 leg, 5/16 in Fillet Weld.)

DETERMINE LIMITING WIDTH THICKNESS RATIO FOR COMPRESSION ELEMENT, LOCAL BUCKLING (AISC 341-05 Tab. I-8-1)
D / t = 0.044 Es / Fy
h / t = 1.12 (Es / Fy)
Where

0.5

Fy =

46

ksi

Es =

29000

ksi

27.74 , for Pipe

28.12 , for Tube

>

Actual

[Satisfactory]

DETERMINE FACTORED DESIGN LOADS (AISC 341-05 Sec.15.6)


Pu = (1.2 + 0.2SDS)PDL + f1PLL + PE =
Where

629.9

kips

PE = 1.25 Ry [Vn L Lb / (L-e) h] =


Ry =

1.3

609.2

kips

(1.4 for Pipe.)

DETERMINE DESIGN STRENGTH IN COMPRESSION (AISC 360-05 E3)


cPn = cAgFcr =

757.24

c =
Fe =
c =
K =

>

kips

Pu

[Satisfactory]

0.85
2
E / (K

(K

/ r)2 =
0.5

/ r) (Fy / E)

237.8 ksi
=

Fcr =

1.38

(0.658

(Fy/Fe)

0.877 Fe =

)Fy =

42.42 kis, for c


N/A

4.71

kis, for c > 4.71

1.0

DETERMINE CONNECTION DESIGN FORCE


Put = Pu =

629.91

kips (Tension)

DETERMINE BEST FILLET WELD SIZE (AISC 360-05 Sec.J2.2b)


> wMIN =
0.1875 in
w=
5/16
in
< wMAX =
0.4375 in
[Satisfactory]
DETERMINE REQUIRED WELD LENGTH (AISC 360-05 Sec.J2.4)
L = Put / [(4) Fw (0.707 w)]
= 629.9 / [(4) 0.75 (0.6x70)(0.707x5/16)] =

22.63 in
( USE
23
in )
CHECK DESIGN SHEAR RUPTURE CAPACITY OF SLOTTED BRACE
(AISC 360-05 Sec.J4.2)
>
Put
Rn = (0.6Fu)Anu = 1395.10 kips
=
Where
0.75
[Satisfactory]
Fu =

58

ksi (AISC 13th Tab.2-3)

in2
53.45
Anu = 4 t L = 4 x 0.581 x 23 =
DETERMINE REQUIRED THICKNESS OF GUSSET PLATE (AISC 360-05 Tab. J2.4)
tg =
5/8
in
CHECK SHEAR RUPTURE CAPACITY OF GUSSET PLATE (AISC 360-05 J4.2)
Rn = (0.6Fu)Anv = 750.38
=
0.75
Where
Fu =

58

kips

>

t =
U =

0.75
1

An = A - 2 t tg =

[Satisfactory]

28.75

in2

Put

THE GUSSET BLOCK SHEAR CAPACITY (AISC 360-05 J4.3)


Rn = (0.6Fu)Anv + FyAgt =
750.38 + FyAgt

ksi (plate value)

Anv = 2 tg L = 2 x 5/8 x 23 =
CHECK TENSION AT SLOTTED BRACE (AISC 360-05 D.2 b)
tPn = tRyFuUAn =
1146.48 kips
>
Where

Put

__
[Satisfactory]
(LRFD Sec.B3.2d)
2
20.274 in

Page 322 of 533


524

>
Put =
[Satisfactory]

629.91

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Eccentrically Braced Frames Based on CBC 07 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
MAX SERVICE LOADS AT OUTSIDE OF LINK

VDL =

6.8

kips

PDL =

kips

MDL =

17

ft-kips

VLL =

4.8

kips

PLL =

0.7

kips

MLL =

11.3

ft-kips

VE =

8.7

kips (ASCE 7-05 12.4.2.1)

PE =

100

kips

ME =

100

ft-kips

SEISMIC LOADS AT OUTSIDE OF LINK

THE BEAM DESIGN IS ADEQUATE.

(SEE LINK DESIGN SPREADSHEET FOR BALANCE OF INPUT DATA)

DETERMINE FACTORED DESIGN LOADS AT SECTION OF LINK AND BEAM (AISC 360-05 Sec. 15.6b & ASCE 7-05 12.4.2.3)
Vu = (1.2 + 0.2SDS)VDL + f1VLL + VE =

67.0

kips

Pu = (1.2 + 0.2SDS)PDL + f1PLL + PE =

537.9

kips

Mu = (1.2 + 0.2SDS)MDL + f1MLL + ME =

923.0

ft-kips

f1

Where

0.5

Ry =

1.1

Vn =

369.2

(AISC 341-05 Tab. I-6-1)


kips (from link design)

Mn = Vn e / 2 =

738.47 ft-kips

VE = (1.1Ry Vn / VE , link) VE =
PE = 1.1Ry Vn L / 2h =
ME = 1.1Ry Mn =

893.5

46.3

kips

536.1

kips

ft-kips

CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)


bf / (2tf ) =

4.24

0.3 (Es / Fy)0.5 =

<

[ 52 / (Fy)
Where

0.5

7.22

[Satisfactory]

for AISC Seismic 97, Tab. I-9-1]

Es =

29000 ksi

3.14(Es/Fy)0.5(1-1.54Pu/bPy) =
h / tw =

N/A

, for Pu/bPy < 0.125

0.5

<

22.00

[ 520 / (Fy) (1-1.54Pu/bPy) for AISC Seismic 97, Tab. I-9-1]


(Es/Fy)0.5 MAX[1.49, 1.12(2.33 - Ca)] =

55.19 , for Pu/bPy > 0.125

{ MAX[ 191 / (Fy)0.5(2.33-Pu/bPy) , 253 / (Fy)0.5] for AISC Seismic 97, Tab. I-9-1}
Where b =

[Satisfactory]
CHECK UNBALANCED SEGMENT LENGTH
12.38
1 = (L - e - dc) / 2 =
1/2=

, Py = FyA =

6.19

48.8 kips, [AISC Seismic Sec.15.5]

14.8 kips, [AISC 341-05 Sec.15.6.(2)]

Mb, mid =0.02Fy bf tf d =

24.0 ft-kips, [AISC 341-05 Sec.15.6.(2)]

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


Where

c =
K =
MAX(K

kips

at each end of the link segment.)

ft, ( lateral supported at middle of beam outside of link with following design strength.)

Brace Load : Pb,mid = 0.02Fy bf tf =

cPn = cFcrA =

2105

ft, (top & bottom flange bracing with a design strength greater than below will be provided

Brace Load : Pb,link = 0.06Ry Fy bf tf =


2=

0.9

1694.11

kips

0.85
1.0
1/rx, K 2/ry) = 27.34

>

Pu

[Satisfactory]

__

c =

0.361

Fcr =

47.34 ksi

<

200

[Satisfactory]

Page 323 of 533


524

(cont'd)
DETERMINE FLEXURAL DESIGN STRENGTH (AISC-AISC 360-05 F1)
Lb =

6.19

L p = 1.76 ry (E / Fyf)

ft
0.5

9.60

L r = ry X1 [1 + (1 + X2 FL2 )0.5 ]0.5 / FL =

ft
35.27

M p = MIN( Fy Zx , 1.5 Fy Sx) =

1341.7 ft-kips

M r = FL Sx =

ft-kips

940.0

M cr = Cb Sx ry X1 (2 + X12 X2 ry2 / Lb2)0.5 / Lb =


Where

ft-kips

4036.3

Iy

tf

ry

Sx

X 2 = 4 Cw [Sx / (G J)]2 / Iy =

0.0006

42.1

311

1.32

2.72

282

Cw

Zx

29000

11200

19.2

25700

322.0

10.00

ksi

FL = MIN( Fyf - Fr , Fyw) =

b Mn

17113

X 1 = (0.5 E G J A)0.5 / Sx =
Fr =

Mn

ft

40.00

ksi

Cb =

1.30
Mp

1341.7 ft-kips, for L b @ [0 , L p]

MIN{Cb [Mp - (Mp - Mr) (Lb - Lp) / (Lr - Lp)] , Mp}

N/A

ft-kips, for L b @ (L p , L r]

MIN(Mcr , Mp)

N/A

ft-kips, for L b @ (L r , Larger)

= 0.9 Mn =

, (AISC 360-05 F1)

1208

ft-kips

CHECK FLEXURAL CAPACITY (AISC 360-05 C2.1b)


Mux = B1Mu =
Where

923.00

Pe1 = 2EsI x / (K
Cm =

0.6

bMnx = Min(Ry bFyZ, bMn) =

<

ft-kips

2
x) = 35645

kips

[Satisfactory]

(AISC 360-05 C2.1b)

B1 = Cm/(1 - Pu/Pe1) =

Where

b =

0.9

1.000

CHECK INTERACTION CAPACITY (AISC 360-05 H1.1)


For Pu/cPn>0.2,

Pu / cPn + 8 / 9 (Mux / bMnx) =

1.00

For Pu/cPn<0.2,

Pu / (2cPn) + Mux / bMnx =

N/A

<

__
Page 324 of 533
524

[Satisfactory]

1208

ft-kips

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Eccentrically Braced Frames Based on CBC 07 & AISC 341-05
INPUT DATA & DESIGN SUMMARY
W14X145

=>

COLUMN SECTION

=>

COLUMN AXIAL SERVICE LOADS

PDL =

151

kips

PLL =
n=

46
4

kips

NUMBER OF STORIES
COLUMN YIELD STRESS (36 or 50)

Fy =

50

ksi

tw

bf

tf

Sx

42.7

14.8

0.68

15.50

1.09

232

Ix
1710

rx
6.33

ry
3.98

Zx
260

k
1.69

THE COLUMN DESIGN IS ADEQUATE.


=h=

UNBRACED COLUMN LENGTH

14

ft

DETERMINE COLUMN AXIAL SEISMIC LOAD (AISC 341-05 Sec. 15.8)


PE = (n - 1) 1.1 Ry Vn =

1340.3 kips

DETERMINE FACTORED DESIGN LOADS (AISC 360-05 Sec. 15.6b & ASCE 7-05 12.4.2.3)
Pu,t = (0.9 - 0.2SSD ) PDL - PE =

-1235 kips (Tension)

Pu,c = (1.2 + 0.2SDS)PDL + f1PLL + PE =


Where

f1 =

0.5

1575

kips (Compression)

(CBC 1605.4)

CHECK LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)


bf / (2tf ) =

7.11

0.3 (Es / Fy)0.5 =

<

7.22

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


Where

Es =

29000 ksi

3.14(Es/Fy)0.5(1-1.54Pu/bPy) =
h / tw =

N/A

, for Pu/bPy < 0.125

[ 520 / (Fy)0.5(1-1.54Pu/bPy) for AISC Seismic 97, Tab. I-9-1]

<

16.79

(Es/Fy)0.5 MAX[1.49, 1.12(2.33 - Ca)] =

40.74 , for Pu/bPy > 0.125

{ MAX[ 191 / (Fy)0.5(2.33-Pu/bPy) , 253 / (Fy)0.5] for AISC Seismic 97, Tab. I-9-1}
Where c =

[Satisfactory]

0.9

Py = Fy A =

2135

kips

CHECK COMPRESSION CAPACITY (AISC 360-05 E3)


cPn = cFcrA =
Where

c =
K =
MAX(K

1593.27

kips

0.85
1.0
/r
,
K
x x
y/ry) =

>

42.19

c =

0.558

Fcr =

43.90 ksi

Pu

[Satisfactory]

<

200

[Satisfactory]

__
Page 325 of 533
524

PROJECT :
PAGE :
CLIENT :
DESIGN BY :
JOB NO. :
DATE :
REVIEW BY :
Seismic Design for Intermediate/Ordinary Moment Resisting Frames Based on IBC 09, AISC 341-05 & AISC 358-05
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION

=>

W8X48

A
14.1

d
8.5

tw
0.40

bf
8.11
=>

tf
0.69
W14X48

Sx
43.2

Ix
184

rx
3.61

ry
2.08

Zx
49

k
1.08

A
14.1

d
13.8

tw
0.34

bf
8.03

tf
0.60

Sx
70.2

Ix
484

rx
5.86

ry
1.91

Zx
78

k
1.19

BEAM SECTION

STRUCTURAL STEEL YIELD STRESS

Fy =

50

ksi

THE FACTOR AXIAL LOAD ON THE COLUMN


BEAM LENGTH BETWEEN COL. CENTERS
AVERAGE STORY HEIGHT OF ABOVE & BELOW

Pu =
L=
h=

27
33
9

kips
ft
ft

THE DESIGN IS ADEQUATE.


(Continuity column stiffeners 0.75 x 4
with 1/4" fillet weld to web & CP to flanges.
A doubler plate is required with thickness of 1-5/8 in. )

ANALYSIS
THE SEISMIC DESIGN FACTOR COMPARISON (ASCE 7-05, Table 12.2-1)
FRAME TYPE
SMRF
IMRF
OMRF

o
3
3
3

R
8
4.5
3.5

Cd
5 1/2
4
3

CHECK BEAM LOCAL BUCKLING LIMITATION (AISC 341-05 Tab. I-8-1)


bf / (2tf ) =

6.75

0.3 (Es / Fy)0.5 =

<

7.22

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


Where
h / tw =

33.59

Es =

29000 ksi

2.45 (Es / Fy)0.5 =

<

59.00

[Satisfactory]

[ 418 / (Fy)0.5 for FEMA Sec. 3.3.1.2]


CHECK COLUMN LOCAL BUCKING LIMITATION (AISC 341-05 Tab. I-8-1)
bf / (2tf ) =

5.92

0.3 (Es / Fy)0.5 =

<

7.22

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


3.14(Es/Fy)0.5(1-1.54Pu/bPy) =
h / tw =

70.67 , for Pu/bPy < 0.125

[ 520 / (Fy)0.5(1-1.54Pu/bPy) for AISC Seismic 97, Tab. I-9-1]

<

15.85

(Es/Fy)0.5 MAX[1.49, 1.12(2.33 - Ca)] =

N/A

, for Pu/bPy > 0.125

{ MAX[ 191 / (Fy)0.5(2.33-Pu/bPy) , 253 / (Fy)0.5] for AISC Seismic 97, Tab. I-9-1}
Where b =

[Satisfactory]

0.9

, Py = FyA =

705

kips

CHECK CONTINUITY PLATE REQUIREMENT (AISC 358-05 Sec. 2.4.4)


tcf = MIN{ bbf / 6 , 0.4[1.8bbf tbf (FybRyb) / (FybRyb)] 0.5 }=

1.17
in
>
actual tcf
(The continuity plates required.)

tst = tbf for interior connection, or (tbf /2) for exterior connection =
bst =

cPn,st = cFcr A =
Where

1.79 (Es / Fyst )0.5 tst =

<

in

0.60

in,USE

38.10

in, (LRFD Sec. K1.9)


[Satisfactory]

0.75

in

288.0 kips

c =

0.9

hst = dc - 2k =

6.34

K =

0.75

K hst / rst < 200

(AISC 360, E2)

I = tst (2bst + twc) 3 / 12 =

36

in4

A = 2bsttst + 25(twc) 2 =

in2

0.5

rst = ( I / A )

2.02 in

Pu,st = Ryb Fyb bfb tfb =

262.8 kips

<

cPn,st

c =

0.026

Fcr =

35.99

Fyst =

36

0.1875

in

0.3125

in

ksi
kips, plate yield stress

[Satisfactory]

__

The best fillet weld size (AISC 360-05 Sec.J2.2b)


> wMIN =
w=
1/4
in
< wMAX =

[Satisfactory]

[Satisfactory]
The required weld length between A36 continuity plates and column web (AISC 360-05 Sec.J2.2b)
Lw = 0.6tstLnstFy / [(2) Fw (0.707 w)]
Where

Lnet = dc - 2(k + 1.5) =

= (0.75 x 3.3) x 36 / [(2) 0.75 (0.6x70)(0.707x1/4)] =

3.3

<

(Use complete joint penetration groove welds between continuity plates & column flanges.)

Page 326 of 533


524

3.44

in

2(Lnet -0.5) [Satisfactory]

(cont'd)
CHECK PANEL ZONE THICKNESS REQUIREMENT (AISC 341-05 Sec. 10.2d)
tReqD = MAX (t1, t2) =

2.02

in

t1 = Cy Mpr (h - db ) / [0.9 (0.6) Fyc Ryc dc (db - tfb) h] =


Where

2.02

in

Cy = Sb / (Cpr Zb) =

0.78

Cpr =

1.15

(AISC 341-05 Sec. 9.6 & AISC 358-05 Sec. 2.4.3)

Ry =

1.1

(AISC 341-05 Tab. I-6-1)

Sb = 2Ib / db =
Ib = Ix =

in

484

Mpr = Nb CprRyFyb Zb =
Nb =

in

70

826 ft-kips
, (if double side connection of beams, input 2)

t2 = (dz + wz ) / 90 = (db -2tst + dc - 2k) / 90 =


Since twc =
0.40
in
required with thickness of 1-5/8 in.

<

0.21

in

tReqD ,

a doubler plate is

Technical References:
1. AISC 341-05: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, Nov. 16, 2005.
2. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.
3. AISC 358-05: "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications",
American Institute of Steel Construction, Dec 13, 2005.
4. Thomas A. Sabol, Ph.D., S. E.: "2005 AISC Seismic Provisions and Seismic Design Manual Seminar", AISC, Oct. 12, 2006.

__
Page 327 of 533
524

3./4 .0 3/.56 1 6 3 4 3 .- 378

.6-

14 36

3/./ .65 9 -4 3/:-/3 16 ;:; "<

; % ="!

; %! ="!

( "

"# $

!"

%&'

*$
$
/$

#$
%%
&

%'
+&
,,-

(
(

"

'

0 12-'
2*'
-# 314
*5 2 &-'
,,6267& ! 8
9'
-/ : ;,'
4
4
6- 964
< -1 96= .
-1 ,4
>2?6&
<1*=4
67 +4
>-6'
& 76@*'
76< 9'
-/-/'
3%26&& 1, A : '
2B

*
(

"

"

!A C >=4
6
1

"
"
"
(

=, : 0 -, B $

>= A A B

0 & : "#B
E

: 0"#B

, - ./ -0 1 2
6'
&5 '
3 !C >= A A F

&

0 & : "#B
E
0

%&'

, - ./ -0 1 2

: 0"#B ,17 "


63
A
>= A A B

=, : 0 -, B $

$ !
,17

/676

/: -9 $
(

AB

<

0 & : "#B
: 0"#B

$ !

, - ./ -0 1 2

,17

6'
&5 '
3 !C >= A A F

0 &:"#B 0 A

/: -9 $

0 &:"#B
I
, - ./ -0 1 2
(

K
-3, $
-&- $ -=,

I==, :

0
E ==, -=, 0"#=

3"37

A
: 0"#=

63

0
A *:
#

$ "#

*: = #

C,17

*: = #

: 0"#B F,17

6'
&5 '
3 !C >= A A J

%'
+&

-&- $

'
2C0 "
63 D
, - ./ -0 1 2
/&- $ <3 A % $
D /&- : 7&- G

0-93B

%'
+&

/6=6&- ,'
4
4
6- 964
< &'
M60
:

A
63
H 9

'
2

G 9

/676

26-

: E0 B

"9 0 ! !9BF

$ <3 A 0% L

B$

, - ./ -0 1 2

3$

'
2

"37 $

%&'

"#&- $

%'
+&C+4
>-6#'
64
< &-76&&

3 2C&-

, - ./ -0 1 2

=B
$
)

'
2
'
2

, - ./ -0 1 2
/676@*'
76< 964
<4
62?-/=6-9662
312-'
2*'
-# +4
>-6& >2< 314
*5296= 0
2&-"#

'
2

'
2

#= "#= =,= -,= $

-&-

%'
+&

$ =&--&- L

>BF$

#B C

! C,17

6'
&5'
3 !C >= A A F

7&- $ 0 :

,17

J$

! 0 & : "#&- B

$ -&- 0 =&- L -93B :

9$

#=BF

: 0"#B 0

D $

*C&- $

'
2

/676

#=B

)E

)E

*: = #B

! '
2
>3-*>4-3,
0 /6312-'
2*'
-# +4
>-6& 76@*'
76< B
,17 '
2-67'
17 312263-'
12C17 0-=, : B ,17 68-67'
17 312263-'
12$
'
2C
!
'
2C0 : '
2B

=&- $
3 2C&-

/676

*: = #B

: 0"#B 0 A

$0 ! 8

B8

: E0 B

63

=B

! 0 8! B0 ! !8 : BF$

0 &6315+4
6-6 N
1'
2- +626-7>-'
12?711O6964
<& =6-9662312-'
2*'
-# +4
>-6& . 314
*5 2 ,4
>2?6& B

'
2
0 26- A B , - ./ -0 1 2

! " "#
!$% &

&

'
+,

(# &

6 -!,!

+, .

+,&
*

.
.

&
&# . /

&

+,&

.
#&

/0 "1 "2 3*

&

#" #

A B CA /1 &

! "1"29
:." 2

! "#" "

)
.

#=B

)#

7
&

8#2 4 <)
+=

) ! C &
"
,!$>)
,! C)- -)< !== 4

#" #

"

+, *3*.

-5&

"

&

4.

"78

&

&

&

()
4 >.?
!=)!
#< /1 &
)

! )
"#

!$% (

4.!:@ =()+> #
)
:

>.?
!,+?
:!)
=

/8)"

! - ):? !4!,!
"
#"
2
"
8

!=D
DE !)
=@) , F)
=) =4 , ,> >,:? !!?G>)
?)H=E( @!,): =)>! 4 !!?
=,> ) ( F" 2(#
"
DE +! )
4):) 4 , ,> >,:? !!?G>)
?)H=E( @!,): =)>! 4 !!?
=,> ) ( :, -1(#
"
DE ,!$>:?
)
4)
!
! ) =4 , +! )
:?:
!,@! )
: ! !!? @! 3,:@!=4 , !)
=@) ++?
):) =E(
@!,): =)>! 4 !!?
=,> ) (%!
" - @:= " :. ?
( -"%"( " "DE#
!)
=@) , F)
=) =:
!)
=@ ) %!=)
H : >:? !@):,E(
( " #(# 2"

(#

"

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Special Moment Resisting Frames Based on IBC 09, AISC 341-05 & 358-05
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION

=>

W14X257

A
75.6

d
16.4

tw
1.18

bf
tf
16.00
1.89
= > W24X76

Sx
415

Ix
3400

rx
6.71

ry
4.13

Zx
487

k
2.49

A
22.4

d
23.9

tw
0.44

bf
8.99

Sx
176

Ix
2100

rx
9.68

ry
1.92

Zx
200

k
1.18

BEAM SECTION

tf
0.68

STRUCTURAL STEEL YIELD STRESS

Fy =

50

ksi

THE SMRF DESIGN IS ADEQUATE.

FACTOR GRAVITY LOAD ON THE BEAM

wu =

1.31

klf

(Continuity column stiffeners 11/16 x 7

FACTOR AXIAL LOAD ON THE COLUMN


BEAM LENGTH BETWEEN COL. CENTERS
AVERAGE STORY HEIGHT OF ABOVE & BELOW

Pu = 199.6 kips
L=
30
ft
h = 13.25 ft

with 7/16" fillet weld to web & CP to flanges.


A doubler plate is not required. )

REDUCED SECTION DIMENSIONS

a=

5.5

in, [0.5~0.75bf]

(AISC 358-05 Sec. 5.8)

b=

18

in, [0.65~0.85db]

c = 2.125 in, [ 0.1~ 0.25bf]


ANALYSIS

r = (4c2 + b2 ) / 8c =

20.1

in, (AISC 358-05 Fig. 5.1)

Sh = dc/2 + a + b/2 =

22.7

in

CHECK BEAM LOCAL BUCKLING LIMITATIONS (AISC 341-05 Tab. I-8-1)


bf / (2tf ) =

6.61

0.3 (Es / Fy)0.5 = 7.22

<

0.5

[ 52 / (Fy)
Where
h / tw =

48.95

for AISC Seismic 97, Tab. I-9-1]

Es =

29000 ksi

2.45 (Es / Fy)0.5 =

<

[Satisfactory]

59.00

[Satisfactory]

[ 418 / (Fy)0.5 for FEMA Sec. 3.3.1.2]


CHECK COLUMN LOCAL BUCKING LIMITATIONS (AISC 341-05 Tab. I-8-1)
bf / (2tf ) =

4.23

0.3 (Es / Fy)0.5 = 7.22

<

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


3.14(Es/Fy)0.5(1-1.54Ca) =
h / tw =

68.79 , for Ca = Pu/bPy

0.125

[ 520 / (Fy)0.5(1-1.54Pu/bPy) for AISC Seismic 97, Tab. I-9-1]

<

9.68

(Es/Fy)0.5 MAX[1.49, 1.12(2.33 - Ca)] =

N/A

, for Ca = Pu/bPy > 0.125

{ MAX[ 191 / (Fy)0.5(2.33-Pu/bPy) , 253 / (Fy)0.5] for AISC Seismic 97, Tab. I-9-1}
Where b =

[Satisfactory]

0.9

, Py = FyA =

3780

kips

CHECK BEAM - COLUMN RATIO REQUIREMENT (AISC 341-05 Sec. 9.6)


Mpc* / (Mpb* ) =
Where

>

2.40

1.00

[Satisfactory]

Mpc* = Nc Zc (Fyc - Pu / Ag ) + Vcol (db / 2) =


Nc =

Mpb* = Nb (MRBS + Mv) =


Nb =

3844

1.1

670

3844

ft-kips

129

ft-kips

ft-kips

(AISC 341-05 Tab. I-6-1)

ZRBS = Zb - 2c tf (d - tf) =
1.1

, (if double side connection of beams, input 2)

MRBS = CprRyFyb ZRBS =

Cpr =

1598 ft-kips, at center of column

Mv = VRBS Sh = [2MRBS / (L-2Sh) + wu (L-2Sh)/2] Sh =


Ry =

, (if only one column below, input 1)

133

in3

(1.1 from AISC 341-05 Sec. 9.6, or Fy+Fu / 2Fy from AISC 358-05 Sec. 2.4.3)

CHECK BENDING MOMENT AT THE COLUMN FACE (AISC 358-05 Sec. 5.8)
Mf = MRBS + [2MRBS / (L - 2Sh) + wu(L - 2Sh)/2] (a + b/2)
=
Where

753

ft-kips

d =

1.00

<

d Mpe = d Ry Fyb Zb =

917

__

ft-kips

[Satisfactory]

(AISC 358-05 Sec. 2.4.1a)

CHECK CONTINUITY PLATE REQUIREMENT (AISC 358-05 Sec. 2.4.4)


tcf = MIN{ bbf / 6 , 0.4[1.8bbf tbf (FybRyb) / (FybRyb)] 0.5 }=

1.33
in
<
actual tcf
(The continuity plates may not be required.)

tst = tbf for interior connection, or (tbf /2) for exterior connection =

0.68

in,

0.56 (E / Fyst )0.5 tst =

10.93

in, (AISC 360-05 Sec. G3.3)


[Satisfactory]

bst =

in

<

Page 330 of 533


524

USE

0.69

in, ( 11/16 in )

cPn,st = cFcr A =
Where

468.5 kips

c =

0.9

K =

0.75

(Cont'd)

(AISC 360-05 E1)

hst = dc - 2k =

11.42

in

K hst / rst < 200

(AISC 360, E2)

I = tst (2bst + twc) 3 / 12 =

200

in4

Fe = 2 E / (K hst / rst)2 =

A = 2bsttst + 25(twc) 2 =

14

in2

c = (K hst / rst) (Fy / E)0.5 =

0.5

rst = ( I / A )

Fyst =

3.72 in
36

Fcr =

kips, plate yield stress

Pu,st = Ryb Fyb bfb tfb =

336.2 kips

The best fillet weld size (AISC 360-05 Sec.J2.2b)


> wMIN =
w=
7/16
in
< wMAX =

<

cPn,st

0.25

in

(0.658

(Fy/Fe)

[Satisfactory]

54054 ksi, (AISC 360, E3)


0.08

)Fy =

0.877 Fe =

, c

35.99
N/A

4.71

kis, for c > 4.71

[Satisfactory]

0.5625 in

[Satisfactory]
The required weld length between continuity plates and column web (AISC 360-05 Sec.J2.2b)
Lw = 0.6tstLnstFy / [(2) Fw (0.707 w)]
Where

= 0.6 x (0.6875 x 8.4) x 36 / [(2) 0.75 (0.6x70)(0.707x7/16)] =

Lnet = dc - 2(kc + 1.5) =

<

8.4

4.89

in

2(Lnet -0.5) [Satisfactory]

(Use complete joint penetration groove welds between continuity plates & column flanges.)
CHECK PANEL ZONE THICKNESS REQUIREMENT (AISC 341-05 Sec. 9.3)
tReqD = MAX (t1, t2) =

1.09

in

t1 = Cy Mc (h - db ) / [0.9 (0.6) Fyc Ryc dc (db - tfb) h] =


Where

Cy = Sb / (Cpr ZRBS) =

0.76

Sb = 2Ib / db =

111

1598

1321

1.18

>

in

in4

ft-kips

t2 = (dz + wz ) / 90 = (db -2tst + dc - 2k) / 90 =


Since twc =
not required.

in

in2

Ib = Ix - (4 c tfb)(0.5db - 0.5tfb)2 =
Mc = Mpb* =

1.09

0.38

in

tReqD ,

a doubler plate is

CHECK BEAM TO COLUMN CP FLANGES WELD AT 0.04 RADIANS STORY DRIFT (AISC 341-05 Sec. 9.2a)
h
n = Ib
=
Ic L

b=h

3n + 1
=
6n + 1

M Beam =

a=h

0.273

9.14

3n
=
6n + 1

= 0.04h =

ft

3nh
6E
3
2 (1 + 6n ) b
a L
+ a2
+
Ic
I c 2I b

Mu,f = MAX(MBeam , 0.8Mp ) =

3241

3601

4.11

ft

6.36

in

ft-kips, (conservative value


at center line of column)

ft-kips, (AISC 341-05 Sec. 9.2a.2)

0.9

Mn = 0.6FEXX 0.5tfbf(d-tf)2 =
4326
[Satisfactory]
, changeable factor for beam moment at column face

Mp =

833

ft-kips

<

Where

ft-kips, (AISC 360-05 Sec. J2.4)

Technical References:
1. AISC 341-05: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, Nov. 16, 2005.
2. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.
3. AISC 358-05: "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications",
American Institute of Steel Construction, Dec 13, 2005.
4. Thomas A. Sabol, Ph.D., S. E.: "2005 AISC Seismic Provisions and Seismic Design Manual Seminar", AISC, Oct. 12, 2006.

__
Page 331 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Design for Special Moment Resisting Frames Based on CBC 10, AISC 341-05 & 358-05
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION
A
75.6

=>

d
16.4

bf
tf
16.00
1.89
= > W8X67

Sx
415

Ix
3400

rx
6.71

ry
4.13

Zx
487

k
2.49

tw
0.57

bf
8.28

Sx
60.4

Ix
272

rx
3.72

ry
2.12

Zx
70

k
1.33

BEAM SECTION
A
d
19.7
9.0
CBC 2010 Sec. 2205A.4.1.1 APPLY?

W14X257

tw
1.18

tf
0.94
Yes

== >

50

ksi

THE SMRF DESIGN IS ADEQUATE.

wu =

1.31

klf

(Continuity column stiffeners 15/16 x 7.4

Pu =
L=
h=

199.6 kips
30
ft
21
ft

STRUCTURAL STEEL YIELD STRESS

Fy =

FACTOR GRAVITY LOAD ON THE BEAM


FACTOR AXIAL LOAD ON THE COLUMN
BEAM LENGTH BETWEEN COL. CENTERS
AVERAGE STORY HEIGHT OF ABOVE & BELOW

with 3/4" fillet weld to web & CP to flanges.


A doubler plate is required with thickness of 1/4 in. )

REDUCED SECTION DIMENSIONS

a=

5.5

in, [0.5~0.75bf]

(AISC 358-05 Sec. 5.8)

b=

6.3

in, [0.65~0.85db]

1.242 in, [ 0.1~ 0.25bf]

c=
2

ANALYSIS

r = (4c + b ) / 8c =

4.6

in, (AISC 358-05 Fig. 5.1)

Sh = dc/2 + a + b/2 =

16.9

in

CHECK BEAM LOCAL BUCKLING LIMITATIONS (AISC 341-05 Tab. I-8-1)


bf / (2tf ) =

4.43

0.3 (Es / Fy)0.5 =

<

7.22

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


Where
h / tw =

11.12

Es =

29000 ksi

2.45 (Es / Fy)0.5 =

<

59.00

[Satisfactory]

[ 418 / (Fy)0.5 for FEMA Sec. 3.3.1.2]


CHECK COLUMN LOCAL BUCKING LIMITATIONS (AISC 341-05 Tab. I-8-1)
bf / (2tf ) =

4.23

0.3 (Es / Fy)0.5 =

<

7.22

[Satisfactory]

[ 52 / (Fy)0.5 for AISC Seismic 97, Tab. I-9-1]


0.5
3.14(Es/Fy) (1-1.54Ca) =

h / tw =

68.79 , for Ca = Pu/bPy 0.125

[ 520 / (Fy)0.5(1-1.54Pu/bPy) for AISC Seismic 97, Tab. I-9-1]

<

9.68

(Es/Fy)0.5 MAX[1.49, 1.12(2.33 - Ca)] =

N/A

0.5

, for Ca = Pu/bPy > 0.125

0.5

{ MAX[ 191 / (Fy) (2.33-Pu/bPy) , 253 / (Fy) ] for AISC Seismic 97, Tab. I-9-1}
Where b =

[Satisfactory]

, Py = FyA =

0.9

3780

kips

CHECK BEAM - COLUMN RATIO REQUIREMENT (AISC 341-05 Sec. 9.6)


Mpc* / (Mpb* ) =
Where

6.19

>

1.00

[Satisfactory]

Mpc* = Nc Zc (Fyc - Pu / Ag ) + Vcol (db / 2) =


Nc =

Mpb* = Nb (MRBS + Mv) =


Nb =

3844

MRBS = CprRyFyb ZRBS =


1.1

1.1

3844

ft-kips

621 ft-kips, at center of column

259

52

ft-kips

ft-kips

(AISC 341-05 Tab. I-6-1)

ZRBS = Zb - 2c tf (d - tf) =
Cpr =

, (if double side connection of beams, input 2)

Mv = VRBS Sh = [2MRBS / (L-2Sh) + wu (L-2Sh)/2] Sh =


Ry =

, (if only one column below, input 1)

51

in3

(1.1 from AISC 341-05 Sec. 9.6, or Fy+Fu / 2Fy from AISC 358-05 Sec. 2.4.3)

CHECK BENDING MOMENT AT THE COLUMN FACE (AISC 358-05 Sec. 5.8)
Mf = MRBS + [2MRBS / (L - 2Sh) + wu(L - 2Sh)/2] (a + b/2)
=
Where

286

ft-kips

d =

1.00

<

d Mpe = d Ry Fyb Zb =

321

ft-kips

[Satisfactory]

(AISC 358-05 Sec. 2.4.1a)

CHECK CONTINUITY PLATE REQUIREMENT (AISC 358-05 Sec. 2.4.4)


tcf = MIN{ bbf / 6 , 0.4[1.8bbf tbf (FybRyb) / (FybRyb)] 0.5 }=

actual tcf
1.38
in
<
(The continuity plates may not be required.)

tst = tbf for interior connection, or (tbf /2) for exterior connection =
bst =

7.4

in

<

0.56 (E / Fyst )0.5 tst =

0.94

in,

USE

0.94

in, ( 15/16 in )

14.90

in, (AISC 360-05 Sec. G3.3)


[Satisfactory]

(Cont'd)

cPn,st = cFcr A =
Where

712.5 kips

c =

0.9

K =

0.75

(AISC 360-05 E1)

I = tst (2bst + twc) / 12 =


A = 2bsttst + 25(twc)
rst = ( I / A )

0.5

Fyst =

11.42

(AISC 360, E2)

319

Fe = E / (K hst / rst) =

22

in2

c = (K hst / rst) (Fy / E)0.5 =

Fcr =

kips, plate yield stress

Pu,st = Ryb Fyb bfb tfb =

(Fy/Fe)

3.81 in
36

in

in4

hst = dc - 2k =
K hst / rst < 200

425.8 kips

The best fillet weld size (AISC 360-05 Sec.J2.2b)


> wMIN =
w=
3/4
in
< wMAX =

<

cPn,st

0.3125

in

0.8125

in

(0.658

[Satisfactory]

56544 ksi, (AISC 360, E3)


0.08

)Fy =

0.877 Fe =

, c 4.71

35.99
N/A

kis, for c > 4.71

[Satisfactory]

[Satisfactory]
The required weld length between continuity plates and column web (AISC 360-05 Sec.J2.2b)
Lw = 0.6tstLnstFy / [(2) Fw (0.707 w)]
Where

= 0.6 x (0.9375 x 8.4) x 36 / [(2) 0.75 (0.6x70)(0.707x3/4)] =

Lnet = dc - 2(kc + 1.5) =

<

8.4

3.61

in

2(Lnet -0.5) [Satisfactory]

(Use complete joint penetration groove welds between continuity plates & column flanges.)

CHECK PANEL ZONE THICKNESS REQUIREMENT (AISC 341-05 Sec. 9.3)


tReqD = MAX (t1, t2) =

1.41

in

t1 = Cy Mc (h - db ) / [0.9 (0.6) Fyc Ryc dc (db - tfb) h] =


Where

Cy = Sb / (Cpr ZRBS) =

0.77

Sb = 2Ib / db =

44

621

196

<

in

in4

ft-kips

t2 = (dz + wz ) / 90 = (db -2tst + dc - 2k) / 90 =


Since twc =
1.18
required with thickness of 1/4 in.

in

in2

Ib = Ix - (4 c tfb)(0.5db - 0.5tfb)2 =
Mc = Mpb* =

1.41

0.21

in

tReqD ,

a doubler plate is

CHECK BEAM TO COLUMN CP FLANGES WELD AT 0.04 RADIANS STORY DRIFT (AISC 341-05 Sec. 9.2a)

n=

Ib h
=
Ic L

3n + 1
b = h
=
6n + 1

M Beam =

3n
a = h
=
6n + 1

0.056

18.36

= 0.04h =

ft

3nh
6E
=
3
2 (1 + 6n ) b
L
2 a
+
+
a

I c 2I b
Ic

Mu,f = MAX(MBeam , 0.8Mp ) =

546

ft

10.08 in

ft-kips, (conservative value


at center line of column)

ft-kips, (AISC 341-05 Sec. 9.2a.2)

0.9

Mn = 0.6FEXX 0.5tfbf(d-tf)2 =
661
[Satisfactory]
, changeable factor for beam moment at column face

Mp =

292

ft-kips

<

Where

606

2.64

ft-kips, (AISC 360-05 Sec. J2.4)

(Cont'd)

CHECK COLUMN UNDER CONNECTION INELASTIC ROTATION OF 0.03 RADIANS (CBC 2010 Sec. 2205A.4.1.1)

{F} = [K] {
} =

72
9075

9075
1534760

-72
-9075

9075
752220

0
0.03

-72
9075

-9075
752220

72
-9075

-9075
1534760

10.08
0.03

Where drift = [0 ~ 0.04 h] =


Mu, max =

22870

>

in-kips, =

10.08
1905.8

Mn = Fy Zx =

-182
-22870
182
-22870

in
ft-kips
1826.3

ft-kips

[ Caution ! ]

Technical References:
1. AISC 341-05: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, Nov. 16, 2005.
2. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.
3. AISC 358-05: "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications",
American Institute of Steel Construction, Dec 13, 2005.

PROJECT :
CLIENT :
JOB NO. :
Rectangular Section Member Design Based on AISC 360-05
INPUT DATA & DESIGN SUMMARY
STEEL YIELD STRESS
SECTION DIMENSIONS

DATE :

Fy =
t=
d=

STRONG AXIS, x-x, UNBRACED BENDING LENGTH

PAGE :
DESIGN BY :
REVIEW BY :

36
ksi
0.625 in
5
in

Lb =

3.5

ft

STRONG AXIS, x-x, UNBRACED AXIAL LENGTH

K Lx =

3.5

ft

WEAK AXIS, y-y, UNBRACED AXIAL LENGTH

K Ly =

3.5

ft

P =

AXIAL LOAD, ASD


STRONG AXIS, x-x, BENDING LOAD, ASD

Mx =

6
0.9

kips
ft-kips

WEAK AXIS, y-y, BENDING LOAD, ASD


STRONG DIRECTION SHEAR LOAD, ASD

My =
V=

0.8
0.2

ft-kips
kips

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK BENDING CAPACITY (AISC 360-05, F11)

Mn
:b

L bd d 0.08E
M p , for
Fy
t2

1
0.08E L bd 1.9 E
L bd F y
 2 d
Min C b 1.52  0.274 2
M y , M p , for
:b
Fy
Fy
t
t E

d 1.9 E
L
b
Min F cr S x , M p , for
!
Fy

t2

Where

M p = Min( F y Z , 1.6 M y ) =
Z = t d2/ 4 =
3.9

11.7
in3

My = Fy t d2/ 6 =

ft-kips

7.8

ft-kips

6.3

Cb =

:b =
36.0

ksi

>

Mx

[Satisfactory]

1.0

Sx = t d2/ 6 =

F cr = Min[1.9 E C b t 2 / (d L b ) , F y ] =

ft-kips

E=

1.67

, (AISC 360-05, F1)


in3
2.6
, (AISC 360-05, F1)

29000

ksi

8.7

kips

CHECK COMPRESSION CAPACITY (AISC 360-05, E7)

Pn
:c

KL
E
Q
/
d 4.71
or F e t 0.44QF y
Q 0.658 F y F e F y , for
r
QF
y
Ag

:c
KL
E
and F e  0.44QF y
0.877 F e , for r ! 4.71 QF
y

Where

KL / r = 12 0.5 Max( K L x / d , K L y / t) =
F e = S 2 E / (KL / r) 2 =
Qa =

1.00

Q = QsQa =

5.28

232.8
ksi

, (AISC 360-05, E7.2.b)

[Satisfactory]

:c =

1.67

Qs =

1.00

, (AISC 360-05, E7.1.a)

F cr =

4.63

ksi, for Q = 1

, (AISC 360-05, E1)

1.00

CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)


P r 8 M rx M ry
Pr


t 0.2

, for
Pc
P c 9 M cx M cy
0.97
<

P r M rx M ry
Pr


 0.2
, for

Pc
2 P c M cx M cy
Where

>

1.0

[Satisfactory]

Pr =

6.0

kips

Pc = Pn / :c =

8.7

kips, (AISC 360-05 Chapter E)

M rx =

0.9

ft-kips

M cx = M n / : b =

6.3

ft-kips, (AISC 360-05 Chapter F)

M ry =

0.8

ft-kips

M cy = M n / : b =

4.7

ft-kips, (AISC 360-05 Chapter F)

V =

0.2

kips

CHECK SHEAR CAPACITY (AISC 360-05, G2)


V ny / : v =
75.2 / 1.67 =

<

45.0

kips

>

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Simply Supported Member of Triple W-Shapes Design Based on AISC 13th (AISC 360-05)
INPUT DATA & DESIGN SUMMARY
Fy =

50
=>

ksi
W18X65

ry
1.69
32

Ix
Sx
Iy
1070
117
55
ft, (simply supported)

ONE PERPENDICULAR W-SHAPE SECTION


A
d
13.3
16.1
THE ONE W-SHAPE LENGTH
(may not full span)
DOUBLE W-SHAPE DISTANCE
FITTED STIFF THICKNESS
FITTED STIFF SPACING

W-SHAPE YIELD STRESS


DOUBLE PARALLEL W-SHAPE SECTION
A
d
19.1
18.4
THE DOUBLE W-SHAPE SPAN

Sy
14.4

0.0158

tw
0.45

bf
7.59

tf
0.75

=>

W16X45
Ix
Sx
Iy
Sy
586
72.7
33
9.34
ft, (centered on the middle of span)

0.0147

tw
0.35

bf
7.04

tf
0.57

L =

ry
1.57
29

d =
t =
s =

24
0.5
96

in
in
in

rx
7.48

S =

rx
6.64

1.5 kips / ft
V=
H=
1.5 kips / ft
T = 0.7333 ft-kips / ft
P=
96
kips

LATERAL DISTRIBUTED LOAD


DISTRIBUTED TORSION LOAD
AXIAL LOAD (BY RIGID END PLATE OR EQUAL)

THE TRIPLE W-SHAPES DESIGN IS ADEQUATE.


ANALYSIS
DETERMINE GOVERNING DESIGN LOADS ON SIGNAL W-SHAPES
Assume conservatively that the perpendiculat W-Shape only supports the H direction bending load, and the torsion load, T, convert to a coupling force on double W-Shapes.
For one of double W-Shapes, W18X65

Mx = (0.5 V + T / d) S 2/ 8 =

142.9

ft-kips at middle

Lb =

8.0

ft

P = 0.5 P =

48.0

kips at middle

Lx =

8.0

ft

Vx = (0.5 V + T / d) S / 2 =

17.9

kips at end

Ly =

8.0

ft

Vy = (0.5 H) S / 2 =

12.0

kips at end

96.0

ft-kips at middle

Lb =

8.0

ft

Mx = V d / 4 =

0.8

ft-kips at center

Lb =

1.4

ft

P=Hs=

12.0

kips at center

Ly =

2.0

ft

For one perpendicular W-Shapes, W16X45

Mx = (0.5 H) S 2/ 8 =
For stiff. plate vert. section, 0.5" x 16.9"

CHECK COMBINED COMPRESSION AND BENDING CAPACITY OF SINGLE DOUBLE W-SHAPE (AISC 360-05, H1)

P r + 8 M rx + M ry
P c 9 M cx M cy

, for P r 0.2
Pc

P r + M rx + M ry
2Pc
M cx M cy

, for P r < 0.2


Pc

Where

Pr =

48.0

kips

M rx =

142.9

ft-kips

M ry =

9.6

Pc = Pn / c =

944

/ 1.67 =

[Satisfactory]

565.0 kips, (AISC 360-05 Chapter E)


Pr

[Satisfactory]

__
520.7

/ 1.67 =

311.8 ft-kips, (AISC 360-05 Chapter F)

93.8

/ 1.67 =

56.1

>

M cy = M n / b =

1.0

ft-kips, 10% perpendicular bending load for over design

>
M cx = M n / b =

<

0.67

>

M rx

[Satisfactory]

ft-kips, (AISC 360-05 Chapter F)


M ry

CHECK WEB SHEAR CAPACITY OF SINGLE DOUBLE W-SHAPE (AISC 360-05, G2)
V nx / v =
248.4 / 1.67 = 148.7 kips
>

Page 336 of 533


524

[Satisfactory]

Vx =

17.9

kips

[Satisfactory]

(cont'd)
CHECK FLANGES SHEAR CAPACITY OF SINGLE DOUBLE W-SHAPE (AISC 360-05, G2)
V ny / v =

380.3 / 1.67 =

>

227.7 kips

Vy =

12.0

kips

[Satisfactory]

96.0

kips

[Satisfactory]

CHECK FLEXURAL CAPACITY OF PERPENDICULAR W-SHAPE (AISC 360-05 Chapter F)


Mn / b =

518.8 / 1.67 =

>

310.7 kips

Mx =

CHECK COMBINED COMPRESSION AND BENDING CAPACITY OF FITTED STIFF PLATE (AISC 360-05, H1)

P r + 8 M rx
P c 9 M cx

, for P r 0.2
Pc

P r + M rx
2Pc
M cx

, for P r < 0.2


Pc

Where

Pr =

12.0

kips

M rx =

0.8

ft-kips

Pc = Pn / c =

72.9

/ 1.67 =

43.7

>
M cx = M n / b =

2.4

<

0.74

/ 1.67 =

1.4

>

1.0

[Satisfactory]

kips, (AISC 360-05 Chapter E)


Pr

[Satisfactory]

ft-kips, (AISC 360-05 Chapter F)


M rx

[Satisfactory]

__
Page 337 of 533
524

PROJECT :
CLIENT :
JOB NO. :
DATE :
Steel Beam Design with Gravity Loading Based on AISC Manual 13th Edition (AISC 360-05)
INPUT DATA & DESIGN SUMMARY
BEAM SECTION (WF, Tube or WT)

=>

W14X22

WF

wDL,1 =

SLOPED DEAD LOADS

0.2

wDL,2 =
0.16

wLL,2 =
CONCENTRATED LOADS
BEAM SPAN LENGTH

L1 =

CANTILEVER LENGTH

L2 =

20

J
0.21

bf
5.00

tf
0.34

tw
0.23

kips / ft
kips / ft
kips / ft

PDL =

kips

PLL =

kips

ft
ft, (0 for no cantilever)

(=

BEAM SLOPE
0 : 12
DEFLECTION LIMIT OF LIVE LOAD
BEAM YIELD STRESS

Sx
29

kips / ft

wLL,1 =

PROJECTED LIVE LOADS

Ix
199

PAGE :
DESIGN BY :
REVIEW BY :

0.00

LL = L / 240

Fy =

50

ksi

THE BEAM DESIGN IS ADEQUATE.


ANALYSIS
DETERMINE REACTIONS, MOMENTS & SHEARS

R 2 = 0.5

+
w DL ,1
w DL ,2
+ w LL ,1 L1 +
+ w LL ,2 ( L1 + 0.5 L 2 ) L 2 + P L1 L 2
cos
cos
L1
L1
=

3.60

kips

w DL ,1
w DL ,2
+ w LL ,1 L1 +
+ w LL ,2 L 2 + P R 2
cos
cos

R1 =

3.60

kips

X1 =

10.00

ft

X2 =

10.00

ft

X3 =

0.00

ft

w DL ,2
+ w LL ,2 L 22 + P L 2 =
M Min = 0.5
cos

( X 1+ X 2 ) =
w DL ,1
+ w LL ,1
cos
8

0.0

ft-kips

M Max =

V max =

3.60

18.0

ft-kips

kips, at R1 right.

CHECK MMin BENDING CAPACITY ABOUT MAJOR AXIS (AISC 360-05 Chapter F)

l = Max ( L 2 , X 3 ) =

0.00

ft, unbraced length

Chapter F Sections for WF


Required Conditions
Double Symmetric
Compact Web
Noncompact Web
Slender Web
Compact Flanges
Noncompact Flanges
Slender Flanges
Applicable Section

F2
x

F3
x

F4

F5

Tube

WT

F7
x

F9

>

x
x

__
x

ok

CHECK MMax BENDING CAPACITY ABOUT MAJOR AXIS (AISC 360-05 Chapter F)
M allowable = M n / b =

>

82.8

ft-kips, top flange fully supported

M Max

[Satisfactory]

Page 338 of 533


524

M allowable = M n / b =
82.8 ft-kips
M Min

[Satisfactory]

where

b =

1.67

, (AISC 360-05 F1)

(cont'd)
CHECK SHEAR CAPACITY ABOUT MAJOR AXIS (AISC 360-05 Chapter G2 or G5)
56.6
kips
V allowable = V n / v =

>
where

v =

V Max

1.67

[Satisfactory]

, (AISC 360-05 G1)

DETERMINE CAMBER AT DEAD LOAD CONDITION


L = L 1 / cos =

20.00

ft, beam sloped span

a = L 2 / cos =

0.00

ft, beam sloped cantilever length

P = P DL cos =

0.00

kips, perpendicular to beam

w 1 = w DL,1 cos =

0.20

klf, perpendicular to beam

w 2 = w DL,2 cos =

0.00

klf, perpendicular to beam

End =

P a 2 ( L + a ) w1 L 3a w 2 a 3 ( 4 L + 3a )

+
=
3EI
24 EI
24 EI

0.00

in, downward perpendicular to beam.


USE C = 0/4" AT CANTILEVER.

Mid

Pa L 2 5w1 L 4 w 2 L 2 a 2
=
+

=
16 EI
384 EI
32 EI

0.12

in, downward perpendicular at middle of beam.


USE C = 0/4" AT MID BEAM.

CHECK DEFLECTION AT LIVE LOAD CONDITION


P = P LL cos =

0.00

kips, perpendicular to beam

w 1 = w LL,1 cos 2 =

0.16

klf, perpendicular to beam

w 2 = w LL,2 cos 2 =

0.00

klf, perpendicular to beam

End =

Pa 2 ( L + a )
w 2 a 3 ( 4 L + 3a )
w 3a
1L
+
cos =
3EI
24 EI
24 EI

<

Mid =

Pa L 2 5w1 L 4 w 2 L 2 a 2
+

cos =
16 EI
384 EI
32 EI

<

0.10

0.00

in, downward to vertical direction.

2L 2 / 240 =

0.00

in

in, downward to vertical direction.

L 1 / 240 =

1.00

__
Page 339 of 533
524

in

[Satisfactory]

[Satisfactory]

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Steel Beam Design with Gravity Loading Based on AISC-ASD 9th


INPUT DATA & DESIGN SUMMARY
BEAM SECTION

W18X40

=>

SLOPED DEAD LOADS

=>

wDL,1 =

1.15

kips / ft

wDL,2 =

0.5

kips / ft

wLL,1 =

0.8

kips / ft

wLL,2 =

0.5

kips / ft

PDL =

kips

PLL =

kips

PROJECTED LIVE LOADS


CONCENTRATED LOADS
BEAM SPAN LENGTH

L1 =

30

ft

CANTILEVER LENGTH

L2 =

10

ft, (0 for no cantilever)

(=

BEAM SLOPE
4 : 12
DEFLECTION LIMIT OF LIVE LOAD
BEAM YIELD STRESS

18.43

Ix
612

Sx
68.4

rT
1.52

bf
6.02

tf
0.53

tw
0.32

LL = L / 360

Fy =

50

ksi

THE BEAM DESIGN IS ADEQUATE.


ANALYSIS
DETERMINE REACTIONS, MOMENTS & SHEARS

R 2 = 0.5

+
w DL ,1
w DL ,2
+ w LL ,1 L1 +
+ w LL ,2 ( L1 + 0.5 L 2 ) L 2 + P L1 L 2
cos
cos
L1
L1
=

50.17

kips

w DL ,1
w DL ,2
+ w LL ,1 L1 +
+ w LL ,2 L 2 + P R 2
cos
cos

R1 =

26.47

kips

X1 =

13.16

ft

X2 =

13.16

ft

X3 =

3.69

ft

w DL ,2
+ w LL ,2 L 22 + P L 2 =
M Min = 0.5
cos

( X 1+ X 2 ) =
w DL ,1
+ w LL ,1
cos
8

111.4 ft-kips

M Max =

V max =

39.89

174.1

ft-kips

kips, at R2 left.

CHECK M Min BENDING CAPACITY (AISC-ASD, F1.3, page 5-46)

l = Max ( L 2 , X 3 ) =
C b = 1.75 + 1.05
rT =

1.52

L c = MIN

76b f

L3 = r T

M 1 + 0.3 M 1
M2
M2
in ,

Fy

L u = MAX r T

10.00
2

= 1.75

, since M1 is 0

Af =

20000
=
(d / A f ) F y

5.39

3.16

in

ft

__

102000C b
Fy

510000C b
=
Fy

ft, unbraced length

12000C b
0.6 ( d / A f ) F y

16.92

= 10.30

ft

Page 340 of 533


524

ft

(cont'd)

2
F y( l / r T )

F y , 0.6 F y =
3 1530000C b
2

F b1 = MIN

170000C b

F b 2 = MIN

( l / r )2

F b3 = MIN

Fy
=
3

27.5

16.7

12000C b
, 0.6 F y =
l (d / A f )

30.0

ksi

ksi

ksi

0.66 F y , for l L c
Fb =

0.6 F y , for L c < l < L u

MAX ( F b1 , F b3 ) , for L u l < L 3

30.0

ksi

MAX ( F b 2 , F b3 ) , for l L 3

f b = M Min / S x =

19.5

ksi

<

Fb

[Satisfactory]

CHECK LOCAL BUCKLING (AISC-ASD Tab. B5.1)


bf / (2tf ) =

5.73

<

65 / (Fy)0.5 =

9.19

640 / (Fy)0.5 =

90.51

[Satisfactory]
d / tw =

<

56.83

[Satisfactory]
CHECK M Max BENDING CAPACITY (AISC-ASD, F1.3, page 5-46)
f b = M Max / S x =

30.5

ksi

<

F b = 0.66 F y =

33.0

ksi

[Satisfactory]

<

F v = 0.4 F y =

20.0

ksi

[Satisfactory]

CHECK SHEAR CAPACITY (AISC-ASD, F4, page 5-49)


f v = V Max / t w d =

7.1

ksi

DETERMINE CAMBER AT DEAD LOAD CONDITION


L = L 1 / cos =

31.62

ft, beam sloped span

a = L 2 / cos =

10.54

ft, beam sloped cantilever length

P = P DL cos =

2.85

kips, perpendicular to beam

w 1 = w DL,1 cos =

1.09

klf, perpendicular to beam

w 2 = w DL,2 cos =

0.47

klf, perpendicular to beam

End =

P a 2 ( L + a ) w1 L 3a w 2 a 3 ( 4 L + 3a )

+
=
3EI
24 EI
24 EI

-0.69

in, uplift perpendicular to beam.


USE C = 3/4" AT CANTILEVER.

Mid

Pa L 2 5w1 L 4 w 2 L 2 a 2
=
+

=
16 EI
384 EI
32 EI

1.36

in, downward perpendicular at middle of beam.


USE C = 5/4" AT MID BEAM.

CHECK DEFLECTION AT LIVE LOAD CONDITION


P = P LL cos =

2.85

kips, perpendicular to beam

w 1 = w LL,1 cos 2 =

0.72

klf, perpendicular to beam

2
w 2 = w LL,2 cos =

0.45

klf, perpendicular to beam

End =

Pa 2 ( L + a )
w 2 a 3 ( 4 L + 3a )
w 3a
1L
+
cos =
3EI
24 EI
24 EI

<

Mid =

Pa L 2 5w1 L 4 w 2 L 2 a 2
+

cos =
16 EI
384 EI
32 EI

-0.19

2L 2 / 360 =

__
<

0.84

in, uplift to vertical direction.


0.67

in

in, downward to vertical direction.

L 1 / 360 =

Page 341 of 533


524

1.00

in

[Satisfactory]

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

WF Simply Supported Beam Design with Torsional Loading Based on AISC 13th (AISC 360-05)
INPUT DATA & DESIGN SUMMARY
= > W10X54
w = 1.15 kips / ft

BEAM SECTION
GRAVITY DISTRIBUTED LOAD
LATERAL POINT LOAD AT MID
TORSION AT MID SPAN
AXIAL LOAD
BEAM LENGTH

F=
T=
P=
L =

5
5.1
96
15

kips
ft-kips
kips
ft

BEAM YIELD STRESS

Fy =

50

ksi

VERTICAL BENDING UNBRACED LENGTH

Lb =

15

ft

AXIAL VERTICAL UNBRACED LENGTH

Lx =

15

ft

AXIAL HORIZONTAL UNBRACED LENGTH

Ly =

7.5

ft

=>

A
15.8

d
10.1

rx
4.38

ry
2.55

Ix
303

Iy
103

Sy
20.6

0.0174

tw
0.37

bf
10.00

ANALYSIS
DETERMINE GOVERNING MOMENTS AT MIDDLE OF SPAN
Mx = w L 2/ 8 =

32.3

ft-kips

My = F L / 4 =

18.8

ft-kips

M0 = T L / (4d) =

22.7

ft-kips

MT = M0 =

13.3

ft-kips

4 sinh

THE BEAM DESIGN IS ADEQUATE.

L 2
2

L sinh L

0.584 ,(Philip page 101)

CHECK TORSIONAL CAPACITY (AISC 360-05 H3.3 & Philip page 100)
f bx / F nx =
Where

<

0.73

1.00

[Satisfactory]

f bx = M x / S x + 2M T / S y =

21.93

ksi

F nx = F y / T = F y / 1.67 =

29.94

ksi

CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)

P r + 8 M rx + M ry
P c 9 M cx M cy

, for P r 0.2
Pc

P r + M rx + M ry
M cx M cy
2Pc

, for P r < 0.2


Pc

Where

Pr =

96

18.8

4/3

[Satisfactory]

kips

M rx = (M x / S x + 2M T / S y ) S x =
M ry =

<

1.08

109.7 ft-kips, (Sim. from Philip page 100)

ft-kips

Pc = Pn / c =

721

/ 1.67 = 431.97 kips, (AISC 360-05 Chapter E)

>

3/4 P r

[Satisfactory]

M cx = M n / b =

252.62 / 1.67 = 151.27 ft-kips, (AISC 360-05 Chapter F)

M cy = M n / b =

130.42 / 1.67 = 78.094 ft-kips, (AISC 360-05 Chapter F)

>
>

M rx
3/4 M ry

[Satisfactory]
[Satisfactory]

DETERMINE DEFLECTIONS

2 sinh

T
=
2GJ

Where

G =

11200

J =

1.82

2
sinh ( L )

__

sinh

ksi

o
0.2213 , max twist angle at middle (Philip page 100)

Es =

29000

in4

Page 342 of 533


524

ksi

Sx
60
tf
0.62

(cont'd)

5w L4
=
vert =
384 E I 3
Where

horiz =

in =

L / 1207

I3 = Ix sin2(90-) + Iy cos2(90-) =

F L3
=
48 E I 4

Where

0.15

0.20

in =

I4 = Ix cos2(90-) + Iy sin2(90-) =

, vertical deflection at middle


303

L / 885

in4 , (AISC 13th Page 17-42)

, horizontal deflection at middle


103

in4 , (AISC 13th Page 17-42)

Technical References:
1. AISC: "Steel Construction Manual 13th Edition", American Institute of Steel Construction, 2005.
2. Philip H. Lin: "Simplified Design for Torsional Loading of Rolled Steel Members", Engineering Journal, AISC, 1977.

__
Page 343 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

WF Simply Supported Beam Design with Torsional Loading Based on AISC Manual 9th
INPUT DATA & DESIGN SUMMARY
= > W10X54
w = 1.15 kips / ft

BEAM SECTION
GRAVITY DISTRIBUTED LOAD
LATERAL POINT LOAD AT MID
TORSION AT MID SPAN
AXIAL LOAD
BEAM LENGTH

F=
T=
P=
L =

5
5.1
96
15

kips
ft-kips
kips
ft

BEAM YIELD STRESS

Fy =

50

ksi

VERTICAL BENDING UNBRACED LENGTH

Lb =

15

ft

AXIAL VERTICAL UNBRACED LENGTH

Lx =

15

ft

AXIAL HORIZONTAL UNBRACED LENGTH

Ly =

7.5

ft

=>

A
15.8

d
10.1

rx
4.38

ry
2.55

Ix
303

Iy
103

Sy
20.6

0.0174

tw
0.37

bf
10.00

ANALYSIS
CHECK LOCAL BUCKLING (AISC-ASD Tab. B5.1)
bf / (2tf ) =

8.13

<

65 / (Fy)0.5 =

9.19

640 / (Fy)0.5 =

90.51

[Satisfactory]
d / tw =

<

27.30

THE BEAM DESIGN IS ADEQUATE.

[Satisfactory]
DETERMINE GOVERNING MOMENTS AT MIDDLE OF SPAN
Mx = w L 2 / 8 =

32.3

ft-kips

My = F L / 4 =

18.8

ft-kips

M0 = T L / (4d) =

22.7

ft-kips

MT = M0 =

13.3

ft-kips

4 sinh

L 2
2

L sinh L

0.584

,(Philip page 101)

DETERMINE GOVERNING UNBALANCED SEGMENT LENGTH (AISC-ASD F1)


L c = MIN[76bf/(Fy)0.5 , 20000/(d/Af)Fy] =
L u = MAX[rT(102000Cb/Fy)

0.5

ft

, 12000Cb/(d/Af)0.6Fy] =

L 3 = rT(510000Cb/Fy)0.5 =
Where

8.96

20.30

ft

22.39 ft

(d/Af) =

1.64

rT =

2.66

Cb =

1.00

in-1

DETERMINE ALLOWABLE BENDING STRESSES (AISC-ASD F1)


=
Fbx =

Where

0.66Fy

N/A

ksi, for L b @ [0, L c]

0.60Fy

30.00

ksi, for L b @ (L c, L u]

MAX(Fb1, Fb3)

N/A

ksi, for L b @ (L u, L 3]

MAX(Fb2, Fb3)

N/A

ksi, for L b @ (L 3, Larger)

Fb1 = MIN{[2/3 - Fy(L /rT)2/(1530000Cb)]Fy , 0.6Fy} =


Fb2 = MIN[170000Cb/(L /rT)2, Fy/3] =

16.67 ksi

Fb3 = MIN[12000Cb/(L d/Af), 0.6Fy] =

30.00 ksi

25.85

CHECK VERTICAL FLEXURAL CAPACITY (AISC-ASD F & Philip page 100)


fbx / Fbx =
Where

0.73

<

1.00

fbx = Mx / Sx + 2MT / Sy =

[Satisfactory]
21.93

ksi

__
Page 344 of 533
524

ksi

Sx
60
tf
0.62

(cont'd)
CHECK COMPRESSION CAPACITY (AISC-ASD E2)
fa / Fa =

<

0.24
fa = P / A =

Where

K =

1.33

[Satisfactory]

6.08

ksi

1.0

Es =

29000
2

Cc = (2 Es/Fy)

0.5

ksi

Fa =

107

KL /r = MAX(KL x/rx, KL y/ry) =


F = (KL / r) / Cc =

41.10

<

1.33

<

(1-F2/2)Fy / (5/3+3F/8-F3/8) =
122Es/[23(KL /r)2] =
200

25.68 ksi, for Cc > (K /r)


N/A

[Satisfactory]

0.38

CHECK COMBINED STRESS (AISC-ASD H1)


fa / Fa =

fa
Fa

>

0.24

C mx f bx

Where

fa
F bx
F 'ex
Cm =

f
1 a F by
F 'ey

10.92

ksi

Fby = 0.75 Fy =

37.50

ksi

88.39

ksi

1.33

1.00

12 2E

=
23

0.6 F y

C my f by

fby = My / Sy =

'
F ex

fa

0.15

f bx
F bx

Klx

F 'ey

23

rx

f by
F by

12 2E

f by
fa
f
+ bx +
=
Fa
F bx
F by

1.22

<

1.33

1.26

<

1.33

Kl y

= 120.18 ksi

ry

<== Not applicable.

[Satisfactory]
DETERMINE DEFLECTIONS

2 sinh

T
=
2GJ

Where

G =

11200

J =

1.82

vert =

5w L4
=
384 E I 3

Where

horiz =

0.15

sinh

L
2

o
0.2213 , max twist angle at middle (Philip page 100)

ksi
in4

in =

L / 1207

I3 = Ix sin2(90-) + Iy cos2(90-) =

F L3
=
48 E I 4

Where

2
sinh ( L )

0.20

in =

I4 = Ix cos2(90-) + Iy sin2(90-) =

, vertical deflection at middle


303

L / 885

in4 , (AISC-ASD Page 6-23)

, horizontal deflection at middle


103

in4 , (AISC-ASD Page 6-23)

Technical References:
1. AISC: "Manual of Steel construction 9th", American Institute of Steel Construction, 1990.
2. Philip H. Lin: "Simplified Design for Torsional Loading of Rolled Steel Members", Engineering Journal, AISC, 1977.

__
Page 345 of 533
524

ksi, for Cc < (K /r)

PROJECT :
CLIENT :
JOB NO. :
DATE :
HSS (Tube, Pipe) Member Design with Torsional Loading Based on AISC 360-05
INPUT DATA & DESIGN SUMMARY
MEMBER SHAPE (Tube or Pipe) & SIZE

HSS12X12X5/8
Fy =

STEEL YIELD STRESS

46

TORSIONAL FORCE

Tr =
Pr =

AXIAL COMPRESSION FORCE

46

< ==

63

ft-kips, ASD

kips, ASD

kL x =

20

ft

WEAK AXIS EFFECTIVE LENGTH

kL y =

20

ft

STRONG AXIS BENDING MOMENT

M rx =

250

ft-kips, ASD

STRONG DIRECTION SHEAR LOAD, ASD

Lb =

WEAK DIRECTION SHEAR LOAD, ASD

20

ft, (AISC 360-05 F2.2.c)

V strong =

13

kips

M ry =

30

ft-kips, ASD

V weak =

10

kips

WEAK AXIS BENDING MOMENT

Tube

ksi

STRONG AXIS EFFECTIVE LENGTH

STRONG AXIS BENDING UNBRACED LENGTH

PAGE :
DESIGN BY :
REVIEW BY :

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK TORSIONAL CAPACITY (AISC 360-05, H3.1)

0.6 F y , for

E t
h
E
, for
3.07
t
Fy h
Fy

2 ( B t )( H t ) t 4.5 ( 4 ) t 3 0.6 F y 2.45


Tc =

1
T

Tn =

0.458

( D t ) t

Where

E 2

( h / t )2

, for HSS Tube

h
260
t

, for

221.5
ft-kips

>

h
E
2.45
t
Fy

Max

B
12.00

T =

1.23E
,
(5 / 4)
L D
D t
H
12.00

1.67

h
10.13

Tr
[Satisfactory]

0.60 E
( 3/ 2 )
D
t

, for HSS Pipe

t
0.63

E
29000

,ASD

CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)

P r + 8 M rx + M ry
P c 9 M cx M cy

, for P r 0.2
Pc

P r + M rx + M ry
M cx M cy
2Pc

, for P r < 0.2


Pc

Where

Pc = Pn / c =

986

<

1.16

1.3
[Satisfactory]
(IBC 06 / CBC 07, 1605.3.2)

/ 1.67 = 590.28 kips, (AISC 360-05 Chapter E)

>

Pr

[Satisfactory]

M cx = M n / b =

417.83 / 1.67 = 250.20 ft-kips, (AISC 360-05 Chapter F)

M cy = M n / b =

417.83 / 1.67 = 250.20 ft-kips, (AISC 360-05 Chapter F)

>
>

M rx

[Satisfactory]

M ry

[Satisfactory]

CHECK SHEAR CAPACITY (AISC 360-05, G2)


V n,strong / v =

276.0 / 1.67 =

165.3 kips

>

V strong =

13.0

kips

[Satisfactory]

V n,weak / v =

276.0 / 1.67 =

165.3 kips

>

V weak =

10.0

kips

[Satisfactory]

CHECK COMBINED TORSION, SHEAR, COMPRESSION, AND BENDING CAPACITY (AISC 360-05, H3.2)

P r + M rx + M ry + Max V strong , V weak + T r


V c, strong V c, weak T c
P c M cx M cy
Torsion Neglected , for T r 0.2
Tc

, for T r > 0.2


Tc

1.3

<

1.3 [Satisfactory]
(IBC 06 / CBC 07, 1605.3.2)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Plate Girder Design Based on AISC Manual 13th Edition (AISC 360-05)
INPUT DATA & DESIGN SUMMARY
STEEL YIELD STRESS

Fy =

50

ksi

=
=
=
=

72
1
1
60

ft
kips / ft
kips / ft
kips

P LL =

60

kips

c =

24

ft

TOP FLANGE WIDTH

b f,top =

16

in

TOP FLANGE THICKNESS

t f,top =

1.5

in

BOTTOM FLANGE WIDTH

b f,bot =

16

in

BOTTOM FLANGE THICKNESS

t f,bot =

1.5

in

tw =
d =

0.5
53

in
in

1/4 x 7 STIFFENER, E. SIDES, AT SUPPORTS ONLY.

Lb =

ft

FLANGE TO WEB WELDING USE 5/16 in - 24 in @ 41 in o.c.

SIMPLY SUPPORTED SPAN


SUPERIMPOSED UNIFORM DEAD LOAD
UNIFORM LIVE LOAD
POINT DEAD LOAD

S
DL
LL
P DL

POINT LIVE LOAD


DISTANCE POINT LOAD TO END

WEB THICKNESS
BEAM DEPTH
UNBRACED LENGTH

THE GIRDER DESIGN IS ADEQUATE.


ANALYSIS
CHECK LIMITING WIDTH-THICKNESS RATIOS FOR WEB (AISC 360-05 Table B4.1)
hc / tw =

where

<
>

100.00

r =

137.27

p =

90.55

Noncompact Web
29000 ksi

E=

r = 5.7 (E / F y ) 0.5 =

137.27

p = (h c / h p ) (E / F y ) 0.5 / (0.54 M p / M y -0.09) 2 =


p = 3.76 (E / F y ) 0.5 =

93.26

,for A f,top

90.55

A f,bot

,for A f,top = A f,bot

hc =

50.00

in

hp =

50.00

in

Mp =

6452.1

ft-kips

My =

5824.6

ft-kips

CHECK LIMITING WIDTH-THICKNESS RATIOS FOR FLANGES (AISC 360-05 Table B4.1)
0.5 b f,top / t f,top =

<
<

5.33

r =

17.04

p =

9.15

Compact Flanges
where

r = 0.95 (k c E / F L ) 0.5 =

17.04

p = 0.38 (E / F y ) 0.5 =

9.15

k c = Min [0.76 , Max (0.35 , 4 / (h / t w ) 0.5 )] =


in3
1398
S xc =
S xt =
FL =

35

0.39
1398

in3

ksi, (AISC 360-05 Table note B4.1 & Eq F4-6)

DETERMINE CRITERIA FOR ALLOWABLE FLEXURAL STRENGTH (AISC 360-05 Table F1.1)

Required Conditions
Double Symmetric
Compact Web
Noncompact Web

F2
x
x

Chapter F Sections
F3
F4
F5
x
x
x
M allowable = M n / b =

Slender Web
Compact Flanges
Noncompact Flanges
Slender Flanges
Applicable Section

3806.0 ft-kips
( from following analysis)

ok

DETERMINE ALLOWABLE FLEXURAL STRENGTH , Mn / Wb , BASED ON AISC 360-05 Chapter F2


<== Not Applicable.
L p = 1.76r y

L r = 1.95r ts
where

E
Fy

E
0.7 F y

13.23

Jc
S xh0

ft

1 + 1 + 6.76

0.7 F y S x h 0
E
Jc

r ts

ry =

3.75

in

Sx =

1398

in3

h0 =

51.50

in

Iy =

1025

in4

E
0.7 F y

32.74 ft

(cont'd)
Cw = Iy h02 / 4 =
J = [ 2 bf tf3

679321 , (AISC 360-05 F2.2)


4
+ (d - t f ) t f 3 ] / 3 =
38.146 in , (Galambos 1968)
(Use

r ts =[( I y C w ) / S x )]
c =
1.0

F cr =

C b 2E
Lb
r ts

4.34

in
Cb =

, (AISC Manual 13th Table 3-1, page 3-10)

Lb
r ts

S xh0

1.0

586.73 ksi

for L b L p

0.5

Jc

1 + 0.078

4
4.0314 in )

J=

0.5

M n, F 2 = Min C b M

(M

Min ( F cr S x , M
M allowable, F2 =M n / b =

0.7 F y S x )

Lb L p
Lr L p

, M

for L p < L b L r

6452.1 ft-kips

for L r L b

3863.5 ft-kips

where

b =

1.67

, (AISC 360-05 F1)

DETERMINE ALLOWABLE FLEXURAL STRENGTH , Mn / Wb , BASED ON AISC 360-05 Chapter F3


<== Not Applicable.

M p ( M p 0.7 F y S x )

M n, F 3 =

0.9 E k c S x

, for Noncompact Flanges

7600.9 ft-kips

, for Slender Flanges

2
where

pf
rf pf

= b f / (2 t f ) =

5.33

pf = p =

9.15

rf = r =

M allowable, F3 =Min(M n,F2 , M n,F3 ) / b =

17.04

3863.5 ft-kips

DETERMINE ALLOWABLE FLEXURAL STRENGTH , Mn / Wb , BASED ON AISC 360-05 Chapter F4


E

L p = 1.1r t

L r = 1.95r t

where

Fy

9.59

FL

S xc h 0

ft

a w =h c t w / (b fc t fc ) =

rt =

b fc

2
1
12 h 0 + a w h
d
6
h 0d

M yc = S xc F y =

4.34

R pc

100.00

pw = p =

93.26

p
yc

Min

F cr =

yc

Lb
rt

ft

6452.1 ft-kips
M yt = S xt F y =

rw = r =

5824.6 ft-kips
137.27

for h c / t w pw

C b 2E

33.05

in

5824.6 ft-kips

= hc / tw =

1.04

M p = Min [Z x F y , 1.6S xc F y ] =

S h
1 + 1 + 6.76 F L xc 0
E
J

yc

1 + 0.078

J
S xc h 0

pw
rw pw

Lb
rt

yc

1.0912

for h c / t w > pw

= 586.58 ksi, (for I yc / I y =

0.50

>

0.23, AISC 360-05 F4-5 )

R pc M yc , for L b L p
M n, F 4.2 = Min C b R pc M yc ( R pc M yc F L S xc )

Lb L p
Lr L p

Min ( F cr S xc , R pc M yc ) , for L r L b

, R pc M yc

, for L p < L b L r

6355.97 ft-kips

(cont'd)

R pc M yc , for Compact Flanges


R pc M yc ( R pc M yc F L S xc )

M n, F 5.3 =

0.9 E k c S xc

R pt =

p
yt

Min

, for Noncompact Flanges

rf pf

6356

ft-kips

, for Slender Flanges

2
M

pf

for h c / t w pw

yt

yt

pw

rw pw

yt

1.0912

for h c / t w > pw

M allowable, F4 = Min( M n,F4.2 , M n,F4.3 , R pt M yt ) / b =

3806.0

ft-kips

DETERMINE ALLOWABLE FLEXURAL STRENGTH , Mn / Wb , BASED ON AISC 360-05 Chapter F5


<== Not Applicable.

Lr = rt

E
0.7 F y

32.73

Fy ,

ft

Lb L p

for

Min C b F y ( 0.3F y )

Lb L p
Lr L p

, Fy

L p < Lb L r

for

F cr , F 5.2 =

=
C b 2E

Min

Fy ,

, Fy

Lb
rt

0.9 E k c
bf
2t f

R pg = Min 1

for

ksi

50

ksi

L r Lb

for Compact Flanges

F y ( 0.3F y )
F cr , F 5.3 =

50

pf
rf pf

for Noncompact Flanges

for Slender Flanges

Min ( a w , 10 )
E
hc
5.7
1200 + 300 Min ( a w , 10 ) t w
Fy

, 1.0 =

M allowable, F5 = Min( R pg F y S xc , R pg F cr,F5.2 S xc , R pg F cr,F5.3 S xc , F y S xt ) / b =

3487.8 ft-kips

DETERMINE ALLOWABLE SHEAR STRENGTH , Vn / Wv , BASED ON AISC 360-05 Chapter G2


h = d - t f,top - t f,bot =
a =

kv =

71.4

5+

( a / h )2

50

in

h / tw =

ft

, for a / h3

Aw =

2
26.50 in

E
1.0 , for h / t w1.10 k v
Fy

5 , for a / h >3

5.00

V n = 0.6 F y A w C v =

348.13 kips

V allowable = V n / v =

208.46 kips

TOTAL SUPERIMPOSED GRAVITY LOAD


w = DL + LL =
2.000 kips / ft

100

Cv

1.10
h /tw

k vE , for 1.10 k vE < h / 1.37 k vE =


tw
Fy
Fy
Fy

0.438

E
1.51E k v
, for 1.37 k v < h / t w
Fy

( h / t w )2 F y
v =

P = PDL + PLL =

1.67

120.00

, (AISC 360-05 G1)

kips

CHECK EACH SECTION CAPACITIES


Section
Distance
d (in)
y (in)

Left
0
53
27

0.06 S
4.00
53
27

0.11 S
8.00
53
27

0.17 S
12.00
53
27

0.22 S
16.00
53
27

0.28 S
20.00
53
27

Point
24.00
53
27

0.44 S
32.00
53
27

0.56 S
40.00
53
27

0.67 S
48.00
53
27

0.78 S
56.00
53
27

0.89 S
64.00
53
27

Right
72.00
53
27

I (in4)
Wt (plf)
V (kips)
M (ft-k)

37044
248.4
160.94
0

37044
248.4
151.95
626

37044
248.4
142.96
1216

37044 37044 37044


248.4
248.4
248.4
133.96 124.97 115.97
1769
2287
2769

37044
248.4
0.00
3215

37044
248.4
31.01
3039

37044
248.4
48.99
2719

37044
248.4
66.98
2255

37044
248.4
84.97
1647

37044
248.4
102.96
896

37044
248.4
120.94
0

(cont'd)
0

BENDING LOADS & CAPACITY

-500

Moments

-1000
-1500

-2000

-2500

-3000
-3500
-4000

Length
M max = 3215.08 ft-kips @

24.00 ft, from heel.

< M allowable =
[Satisfactory]

3806

ft-kips

Shear Forces

SHEAR LOADS & CAPACITY


0.00
-100.00
-200.00
-300.00
Length
V max =

160.94 kips

0.00

< V allowable =

ft, from heel.


208.46 kips

[Satisfactory]

DETERMINE DEFLECTION AT MID SPAN

DL

3/ 2
5w L 4
0.06415 Pb
+
( L 2 b 2 ) =
384 EI
EIL

where

LL

E=

29000

I=
b=

37044
0.6

0.72
in ( L / 1195 )
(for camber, self Wt included.)

ksi
in4
ft

3/ 2
5w L 4
0.06415 Pb
+
( L 2 b 2 ) =
384 EI
EIL

where

60

P=

w=

1.248

kips / ft

P=
L=

60
72.0

kips
ft

0.58

kips

in ( L / 1482 )

w=

1.000

kips / ft

DETERMINE FLANGE TO WEB WELDING (AISC 360-05 J2.4 )

w =

5/16

w min =

3/16

w max =
=

7/16
2.0

V max =

160.94

in
in, < w
in, > w
kips

Q = A f (d - y - 0.5 t f,top ) =
v max = V max Q / I =
A=

24

2.68

618

in3

kips / in

B=

in

( 0.6 F EXX )( 0.707 w ) A =


v max

41

in. o.c.

USE 5/16 in - 24 in @ 41 in o.c.


DESIGN STIFFENERS

1. BEARING STIFFENERS ARE REQUIRED AT EACH END SUPPORT. (AISC 360-05, J10.8)
2. CHECK LOCAL WEB YIELDING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.2)
R=P=
120.00
kips
N=
0
in, bearing length, point.
k = t f,top + w =
1.5

1.81

in

R
, for c > d
t w ( N + 5k )
R
, for c d
t w ( N + 2.5 k )

26.48

<

Fy /

[Satisfactory]

(cont'd)
3. CHECK WEB CRIPPLING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.3)

2.0
tw
tf

N
1+3
d

tw
tf

Rn / = 1 /
0.40t 2w

1.5

N
d

0.80t 2w 1+3

EF ywt f
tw

1.5

EF ywt f
tw

, for c 0.5 d

208.57

>

[Satisfactory]

[Satisfactory]

, for c<0.5 d

(Note : If item 2, local web yielding is Satisfactory, this item does not need to be checked.)
4. CHECK SIDESWAY WEB BUCKING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.4)
d c = d - 2k =
Cr =

49.38
960000

in

ksi

(d c / t w ) / (l / b f ) =
1.76

16.46

C r t 3wt f
h

C r t 3wt f

Rn / = 1 /

/
0.4 d c t w
l /b f

h2

/
1+ 0.4 d c t w
l /b f

/
, for d c t w <1.7
l /b f
3

/
, for 1.7 d c t w < 2.3
l /b f

= 120.00

>

/
P , for d c t w 2.3
l /b f

(Note : If item 2, local web yielding is Satisfactory, this item does not need to be checked.)
5. DETERMINE STIFFENER SIZE.
tw =

in

5/8

b st / t w =

b st =

Ag =

11.75

R=

160.9

kips

c =

1.67

, (AISC 360-05 E1)

K /r=

0.75 h / ( I / A eff ) 0.5 =

10.2

Cc =

4.71 ( E / F y ) 0.5 =

113

Fe =

2E

( kl / r ) 2

2751.51

Fy

R n / c = A g / c

ksi

0.658 F e F y , for
0.877 F e

in

< 0.56 (E / Fy)0.5 , (AISC 360-05 Table B4.1)


[Satisfactory]
4
I =
159 in

11.20
in2

kl
Cc
r

kl
, for
> Cc
r

349.1

>

kips, (AISC 360-05 E2)


R

[Satisfactory]

Technical Reference:
1. AISC: "Steel Construction Manual 13th Edition", American Institute of Steel Construction, 2005.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Plate Girder Design Based on AISC-ASD 9th, Chapter G


INPUT DATA & DESIGN SUMMARY
STEEL YIELD STRESS

Fy =

50

ksi

=
=
=
=

72
1
1
60

ft
kips / ft
kips / ft
kips

S
DL
LL
P DL

SIMPLY SUPPORTED SPAN


SUPERIMPOSED UNIFORM DEAD LOAD
UNIFORM LIVE LOAD
POINT DEAD LOAD

P LL =

60

kips

TOP FLANGE WIDTH

b f,top =

16

in

TOP FLANGE THICKNESS

t f,top =

1.5

in

BOTTOM FLANGE WIDTH

b f,bot =

16

in

BOTTOM FLANGE THICKNESS

t f,bot =

1.5

in

tw =
d =
c =
l =

0.5
70
24
8

in
in
ft
ft

POINT LIVE LOAD

WEB THICKNESS
BEAM DEPTH
DISTANCE POINT LOAD TO END
UNBRACED LENGTH

1/4 x 7 STIFFENER, E. SIDES, AT SUPPORTS ONLY.


FLANGE TO WEB WELDING USE 5/16 in - 24 in @ 57 in o.c.

THE GIRDER DESIGN IS ADEQUATE.


ANALYSIS
DETERMINE Fb (AISC-ASD, F1.3, page 5-46)
C b = 1.75 + 1.05

rT =

L c = MIN

76b f
Fy

L u = MAX r T

L3 = r T

24.00 in

Af =

20000

(d / A f ) F y

4l 2 S 2
4 2 2
+ 0.3 l S
S2
S2

1.75 + 1.05

in

4.16

M 1 + 0.3 M 1
M2
M2

11.43

35.42

1.02

ft

102000C b
12000C b
= 15.84
,
0.6 ( d / A f ) F y
Fy

510000C b
=
Fy

ft

ft

2 F y( l / r T )

F y , 0.6 F y =
3 1530000C b
2

F b1 = MIN

170000C b

F b 2 = MIN

(l / r )

F b3 = MIN

Fb =

Fy
=
3

30.0

16.7

12000C b
, 0.6 F y =
l (d / A f )

30.0

ksi

ksi

ksi

0.66 F y , for l L c
0.6 F y , for L c < l < L u

MAX ( F b1 , F b3 ) , for L u l < L 3

33.0

ksi

MAX ( F b 2 , F b3 ) , for l L 3
CHECK WEB SLENDERNESS (AISC-ASD, G1, page 5-51)
a =
h / tw =

71.4
134.00

ft, the max clear distance between stiffeners.

__
>

760

132.30

Fb

14000

<

F yf ( F yf + 16.5 )

2000

[Satisfactory]

for a > 1.5h

for a 1.5h

F yf

Page 352 of 533


524

282.84
[Satisfactory]

(cont'd)
DETERMINE ALLOWABLE FLEXURAL STRESS (AISC-ASD G2, pg 5-51)
Aw =

in

33.50

= 0.6 F yw / F b =

A w h 760
R PG = MIN 1 0.0005
Af t
Fb

12 +
R e = MIN

( 3 3)

Aw
Af

, 1.0 =

0.91

0.999

, 1.0 =

0.998

12 + 2 A w
Af

F b = F b R PG R e =
'

32.89

ksi

DETERMINE ALLOWABLE SHEAR STRESS (F4-2, pg 5-49)


h = d - t f,top - t f,bot =
4.0+

kv

5.34

(a / h)

5.34+

Fv

= MIN

h / tw =

134
45000 k v

, for a / h1.0

4.0

(a / h)

in

67

Cv

5.36

, for a / h >1.0

CvF y
, 0.4 F
2.89

TOTAL SUPERIMPOSED GRAVITY LOAD


w = DL + LL =
2.000 kips / ft

F y( h / t w)
190
h /tw

, for C v 0.8

0.27

k v , for
C v >0.8
Fy

4.65 ksi

P = PDL + PLL =

120.00

kips

CHECK EACH SECTION CAPACITIES


Section
Distance
d (in)
y (in)

Left
0
70
35

0.06 S
4.00
70
35

0.11 S
8.00
70
35

0.17 S
12.00
70
35

0.22 S
16.00
70
35

0.28 S
20.00
70
35

Point
24.00
70
35

0.44 S
32.00
70
35

0.56 S
40.00
70
35

0.67 S
48.00
70
35

0.78 S
56.00
70
35

0.89 S
64.00
70
35

Right
72.00
70
35

I (in4)
Wt (plf)
V (kips)
M (ft-k)
f v (ksi)

68848
277.3
161.98
0

68848
277.3
152.87
630

68848
277.3
143.77
1223

68848 68848 68848


277.3
277.3
277.3
134.66 125.55 116.44
1780
2300
2784

68848
277.3
0.00
3232

68848
277.3
30.89
3057

68848
277.3
49.11
2737

68848
277.3
67.33
2272

68848
277.3
85.55
1660

68848
277.3
103.77
903

68848
277.3
121.98
0

4.63

4.37

4.11

3.85

3.59

3.33

0.00

0.88

1.40

1.92

2.44

2.96

3.49

f b (ksi)

0.00

3.84

7.46

10.86

14.03

16.98

19.71

18.65

16.70

13.86

10.13

5.51

0.00

fb (ksi) & F'b (ksi)

BENDING STRESS
0.00
-10.00
-20.00
-30.00
-40.00
Length
f b,max =

19.71 ksi

<

@
F' b =

24.00 ft, from heel.


32.89 ksi

[Satisfactory]

fv (ksi) & Fv (ksi)

SHEAR STRESS
0.00
-2.00
-4.00
-6.00

__
Length

Page 353 of 533


524

(cont'd)
f v,max =

4.63 ksi

<

0.00

Fv =

ft, from heel.

4.65 ksi

[Satisfactory]

DETERMINE DEFLECTION AT MID SPAN

DL

3/ 2
5w L 4
0.06415 Pb
+
( L 2 b 2 ) =
384 EI
EIL

where

LL

E=

29000

I=
b=

68848
0.6

0.40
in ( L / 2173 )
(for camber, self Wt included.)

ksi
in4
ft

3/ 2
5w L 4
0.06415 Pb
+
( L 2 b 2 ) =
384 EI
EIL

where

60

P=

w=

1.277

kips / ft

P=
L=

60
72.0

kips
ft

0.31

kips

in ( L / 2755 )

w=

1.000

kips / ft

DETERMINE FLANGE TO WEB WELDING


w =
w min =

5/16
3/16

in
in, < w

w max =

7/16

in, > w

V max =

161.98

kips

Q = A f (d - y - 0.5 t f,top ) =
v max = V max Q / I =
A=

24

in

822

1.93

kips / in
B=

in

( 0.3F u ) ( 0.707 w) A =

57

v max

in. o.c.

USE 5/16 in - 24 in @ 57 in o.c.


DESIGN STIFFENERS

1. BEARING STIFFENERS ARE REQUIRED AT EACH END SUPPORT. (AISC-ASD, K1.8, page 5-82)
2. CHECK LOCAL WEB YIELDING FOR THE CONCENTRATED LOAD. (AISC-ASD, K3, page 5-81)
R=P=
120.00 kips
N=
0
in, bearing length, point.
k = t f,top + w =

1.81

in

R
, for c > d
t w ( N + 5k )
R
, for c d
t w ( N + 2.5 k )

<

26.48

[Satisfactory]

0.66F y

3. CHECK WEB CRIPPLING FOR THE CONCENTRATED LOAD. (AISC-ASD, K4, page 5-81)

67.5t 2w 1+ 3

N
d

R =
34 t 2w 1+ 3

N
d

1.5

yw t f

tw
tf

tw

1.5

tw
tf

yw t f

tw

, for c 0.5 d

206.68

>

[Satisfactory]

[Satisfactory]

, for c < 0.5 d

(Note : If item 2, local web yielding is Satisfactory, this item does not need to be checked.)
4. CHECK SIDESWAY WEB BUCKING FOR THE CONCENTRATED LOAD. (AISC-ASD, K5, page 5-81)
d c = d - 2k =

66.38

(d c / t w ) / (l / b f ) =
6800t 3w
/
0.4 d c t w
h
l /b f
R =

in
22.13
3

/
, for d c t w <1.7
l /b f

__

6800t 3w
/
1+ 0.4 d c t w
h
l /b f

/
, for 1.7 d c t w < 2.3
l /b f

120.00

>

/
P , for d c t w 2.3
l /b f

(Note : If item 2, local web yielding is Satisfactory, this item does not need to be checked.)

Page 354 of 533


524

(cont'd)
5. DETERMINE STIFFENER SIZE.
tw =

in

5/8

b st / t w =

11.20

A eff =

11.75

in

fa =

13.8

ksi

Es =

29000

ksi

b st =

C c = (2 E s / F y )

1
Fa =

< 95 / Fy , AISC-ASD, B5.1


[Satisfactory]
4
I =
159 in

0.5

( kl / r )

in

0.5

0.5

K / r = 0.75 h / ( I / A eff )
2

13.7

107

Fy

2C c2

5 3 ( kl / r ) ( kl / r )
+

3
8C c
8C 3c
12 2E

23( kl / r )

for

for

kl
Cc
r

kl
> Cc
r

28.9

ksi, (AISC-ASD, E2, page 5-42)

>

Technical Reference:
1. AISC: "Manual of Steel construction 9th", American Institute of Steel Construction, 1990.

__
Page 355 of 533
524

fa

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Web Tapered Girder Design Based on AISC-ASD 9th, Appendix F


INPUT DATA & DESIGN SUMMARY
STEEL YIELD STRESS

Fy =

50

SIMPLY SUPPORTED SPAN


SUPERIMPOSED DEAD LOAD
LIVE LOAD

S =
DL =
LL =

96
1
0.75

bf =

13

in

FLANGE WIDTH
FLANGE THICKNESS

ksi
ft
kips / ft
kips / ft

tf =

in

WEB THICKNESS

tw =

0.5

in

HEEL DEPTH

d0 =

24

in

MID-SPAN DEPTH
DISTANCE BETWEEN STIFFENERS

dL =
a =

72
24

in
ft

L =
10
ft
UNBRACED LENGTH / PURLIN SPACING
(Diaphragm is not bracing member. L is different with " " in F1.3, pg 5-47)

THE GIRDER DESIGN IS ADEQUATE.


ANALYSIS
TOTAL SUPERIMPOSED GRAVITY LOAD
w = DL + LL =
1.750 kips / ft
ALLOWABLE FLEXURAL STRESS (APP. F7.4, pg 5-103)

Fy
2
1.0
F y 0.60 F y , for F b > F y / 3
6 B F 2s + F 2w
F b = 3
B
where

F 2s +F 2w

Af =

30.00 ksi

, for F b F y / 3
in2

13.00

= MIN[(dL - d0) / d0 , 0.268 L/d0, 6.0] =

1.34

2
15.00 in

A To = tf bf + d0 tw / 6 =
I To = (tf bf3 + d0 tw3 / 6) / 12 =
I To =
ATo

r To

hs

= 1.0 + 0.0230

183

3.49

h w = 1.0 + 0.00385

in

Ld 0 =
Af
L

r To

in4

F s

1.46 in

F w

1.18 in

12000
h sL d o / A f
170000

( h wL / r To )

37.13 ksi

103.99 ksi

1.75
=
1.0+ 0.25

1.21

ALLOWABLE SHEAR STRESS (F4, pg 5-49)

Fv

0.4 F y , for h / t w380 F y


= C F
v y
0.4 F y , for h / t w>380 F y
2.89

where

h = d under investigation - 2 t f =
h / tw =

92
4.0+

kv

(a / h)

5.34+

46
>

5.34

10.01 ksi

in, at first stiffer from end.

380 / F y 0.5 =

Cv
=

4.0
2

45000 k v

54

, for a / h1.0

( a / h)

5.44

__

, for a / h >1.0

Page 356 of 533


524

F y( h / t w )
190
h /tw

, for C v 0.8

k v , for
C v >0.8
Fy

0.58

(cont'd)
CHECK EACH SECTION CAPACITIES
Section
Distance
d (in)

HEEL
0
24

1/24 S
4.00
28

1/12 S
8.00
32

1/8 S
12.00
36

1/6 S
16.00
40

5/24 S
20.00
44

1/4 S
24.00
48

7/24 S
28.00
52

1/3 S
32.00
56

3/8 S
36.00
60

5/12 S
40.00
64

11/24 S MID
44.00 48.00
68
72

I (in4)
Wt (plf)
V (kips)
M (ft-k)
f v (ksi)

3884
125.9
92.00
0

5473
132.7
84.49
353

7374
139.5
76.94
676

9602
146.3
69.37
968

12175
153.1
61.77
1231

15108
159.9
54.15
1463

18416
166.7
46.49
1664

22117
173.5
38.81
1835

26226
180.3
31.10
1974

30758
187.2
23.37
2083

35731
194.0
15.61
2161

7.67

6.03

4.81

3.85

3.09

2.46

1.94

1.49

1.11

0.78

0.49

0.23

0.00

f b (ksi)

0.00

10.84

17.60

21.79

24.26

25.56

26.02

25.88

25.30

24.38

23.23

21.89

20.41

41160
200.8
7.82
2208

47060
207.6
0.00
2224

BENDING STRESS

-fb (ksi)

0.00
-10.00
-20.00
-Fb

-30.00
-40.00
Length
f b,max =

26.02 ksi

<

24.00 ft, from heel.


Fb =

30.00 ksi

[Satisfactory]
SHEAR STRESS
0.00

-fv (ksi)

-2.00
-4.00
-6.00
-8.00

-Fv

-10.00
-12.00
Length
f v,max =

7.67 ksi

<

0.00
Fv =

ft, from heel.

10.01 ksi

[Satisfactory]

DETERMINE DEFLECTION AT MID SPAN

DL

S
0

m DL mun it ds =
EIs

where
Section
Distance
I S (in4)

E=
HEEL
0.00
3884

29000
1/24 S
4.00
5473

mDL (ft-k)

mLL (ft-k)

LL

3.06 in ( Span / 377 )


(for camber, self Wt included.)

S
0

m LL mun it ds =
EIs

1.95 in ( Span / 591 )

ksi

1/12 S
8.00
7374

1/8 S
12.00
9602

1/6 S
16.00
12175

5/24 S
20.00
15108

1/4 S
24.00
18416

7/24 S
28.00
22117

1/3 S
32.00
26226

3/8 S
36.00
30758

5/12 S
40.00
35731

11/24 S MID
44.00 48.00
41160 47060

215

412

590

751

893

1016

1121

1206

1273

1321

1350

1360

138

264

378

480

570

648

714

768

810

840

858

864

munit

0.00

2.00

4.00

6.00

8.00

10.00

12.00

14.00

16.00

18.00

20.00

22.00

24.00

DL,S

0.00

0.01

0.04

0.07

0.10

0.13

0.15

0.16

0.17

0.18

0.18

0.17

0.17

LL,S

0.00

0.00

0.02

0.05

0.07

0.08

0.10

0.10

0.11

0.11

0.11

0.11

0.11

__

Technical Reference:
1. AISC: "Manual of Steel construction 9th", American Institute of Steel Construction, 1990.

Page 357 of 533


524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Web Tapered Girder Design Based on AISC-ASD 9th, Appendix F


INPUT DATA & DESIGN SUMMARY
STEEL YIELD STRESS

Fy =

50

ksi

S =

96

ft

SIMPLY SUPPORTED SPAN


NUMBER OF CONCENTRATED LOADS
SUPERIMPOSED DEAD LOAD

n=
10
( @ 8.7 ft o.c.)
P D = 8.7273 kips

LIVE LOAD

P L = 6.5455 kips

FLANGE WIDTH

bf =

13

in

FLANGE THICKNESS

tf =

in

WEB THICKNESS

tw =

0.5

in

HEEL DEPTH

d0 =

24

in

MID-SPAN DEPTH
DISTANCE BETWEEN STIFFENERS

dL =
a =

72
24

in
ft

L =
UNBRACED LENGTH / PURLIN SPACING
10
ft
(Diaphragm is not bracing member. L is different with " " in F1.3, pg 5-47)

THE GIRDER DESIGN IS ADEQUATE.


ANALYSIS
TOTAL SUPERIMPOSED GRAVITY LOAD
P = PD + PL =
15.273 kips @ 8.7 ft o.c.
ALLOWABLE FLEXURAL STRESS (APP. F7.4, pg 5-103)

Fy
2
1.0
F y 0.60 F y , for F b > F y / 3
3
6 B F 2s + F 2w
F b =
B
where

F 2s +F 2w

Af =

30.00 ksi

, for F b F y / 3
13.00

in2

= MIN[(dL - d0) / d0 , 0.268 L/d0, 6.0] =


3

1.34

2
15.00 in

A To = tf bf + d0 tw / 6 =
3

I To = (tf bf + d0 tw / 6) / 12 =
I To =
ATo

r To

hs

= 1.0 + 0.0230

183

3.49

in

Ld 0 =
Af

h w = 1.0 + 0.00385

r To

in4

F s

1.46 in

F w

1.18 in

12000
h sL d o / A f
170000

( h wL / r To )

37.13 ksi

103.99 ksi

1.75
=
1.0 +0.25

1.21

ALLOWABLE SHEAR STRESS (F4, pg 5-49)

Fv =
where

0.4 F y , for h / t w380 F y


=

Cv F y
0.4 F y , for h / t w>380 F y
2.89
h = d under investigation - 2 t f =
h / tw =

92

4.0+

kv

5.34

( a / h )2

5.34+

4.0

( a / h )2

46
>

10.01 ksi

in, at first stiffer from end.

380 / F y 0.5 =

45000 k v

54

Cv =

__

, for a / h1.0

5.44

, for a / h >1.0

Page 358 of 533


524

F y( h / t w)
190
h/tw

, for C v0.8

kv
, for C v >0.8
Fy

0.58

(cont'd)
CHECK EACH SECTION CAPACITIES
Section
Distance
d (in)

HEEL
0
24

1/22 S
4.36
28

2/22 S
8.73
33

3/22 S
13.09
37

4/22 S
17.45
41

5/22 S
21.82
46

6/22 S
26.18
50

7/22 S
30.55
55

8/22 S
34.91
59

9/22 S 10/22 S
39.27
43.64
63
68

MID
48.00
72

I (in )
Wt (plf)
V (kips)
M (ft-k)

3884
125.9
84.37
0

5633
133.3
83.80
367

7754
140.8
67.93
731

10269
148.2
67.30
1026

13199
155.6
51.36
1319

16564
163.0
50.67
1541

20385
170.4
34.67
1761

24683
177.9
33.91
1910

29479
185.3
17.84
2057

34793
192.7
17.02
2133

40647
200.1
0.89
2205

47060
207.6
0.00
2207

f v (ksi)

7.03

5.91

4.15

3.63

2.48

2.21

1.38

1.24

0.61

0.54

0.03

f b (ksi)

0.00

11.09

18.52

22.24

24.85

25.58

26.01

25.33

24.66

23.27

22.02

12

16

20

25

0.00
20.26
30

-fb (ksi)

BENDING STRESS
0.00
-5.00
-10.00
-15.00
-20.00
-25.00
-30.00
-35.00
Length
f b,max =

26.01 ksi

<

17.45 ft, from heel.

Fb =

30.00 ksi

[Satisfactory]
SHEAR STRESS
0.00
-2.00
-fv (ksi)

-4.00
-6.00
-8.00
-10.00
-12.00
Length
f v,max =

7.03 ksi

<

0.00

Fv =

ft, from heel.

10.01 ksi

[Satisfactory]

DETERMINE DEFLECTION AT MID SPAN

DL

S
0

m DL mun it ds =
EIs

where
Section
Distance
I S (in4)

E=
HEEL
0.00

29000
1/22 S
4.36

3884

mDL (ft-k)

mLL (ft-k)

LL

3.04 in ( Span / 379 )


(for camber, self Wt included.)

S
0

m LL mun it ds =
EIs

1.94 in ( Span / 595 )

ksi
2/22 S
8.73

3/22 S
13.09

4/22 S
17.45

5/22 S
21.82

6/22 S
26.18

7/22 S
30.55

8/22 S
34.91

9/22 S 10/22 S
39.27
43.64

MID
48.00

5633

7754

10269

13199

16564

20385

24683

29479

34793

40647

47060

224

446

627

804

941

1075

1168

1257

1304

1348

1350

143

286

400

514

600

685

743

800

828

857

munit

0.00

2.18

4.36

6.55

8.73

10.91

13.09

15.27

17.45

19.64

21.82

24.00

DL,S

0.00

0.01

0.04

0.09

0.12

0.15

0.17

0.18

0.19

0.19

0.19

0.18

LL,S

0.00

0.01

0.03

0.05

0.08

0.10

0.11

0.12

0.12

0.12

0.12

0.12

__

Technical Reference:
1. AISC: "Manual of Steel construction 9th", American Institute of Steel Construction, 1990.

Page 359 of 533


524

857

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Composite Beam Design with Verco Floor Deck Based on AISC Manual 9th
INPUT DATA & DESIGN SUMMARY
BEAM SECTION

=>

W30X132

FLOOR DECK TYPE

=>

W3-6 1/4" LW

RIBS PERPENDICULAR TO BEAM ?


BEAM SPAN
BEAM SPACING (TRIB. WIDTH)

L =
B =

Yes
52
16

=>

SUPERIMPOSED LOAD

ws =

246

(perpendicular)
ft
ft, o.c.
lbs / ft2

BEAM YIELD STRESS

Fy =

50

ksi

CONCRETE STRENGTH

fc'=

ksi

3/4

in

SHEAR STUD DIA. (1/2, 5/8, 3/4)

NUMBER OF STUD IN ONE RIB

Nr =

A
38.9

d
30.3

Ix
5770

Sx
380

( Total 160 - 3/4 x 4.5" Shear Studs Required)


( 0 13/16 in camber suggested)

THE BEAM DESIGN IS ADEQUATE.


ANALYSIS
CHECK DIMENSION REQUIREMENTS (AISC-ASD I5.1, page 5-61)
t0 =

3.25

in

>

in

[Satisfactory]

hr =

in

<

in

[Satisfactory]

3/4

in

<

3/4

in

[Satisfactory]

H s = h r + 1.5 =
s =
4

4.5
in o.c.

in
<

3
in o.c.

in
[Satisfactory]
[Satisfactory]

wr =

in

>

>
36

in

[Satisfactory]

DETERMINE COMPOSITE PROPERTIES


b = MIN ( L / 4 , B ) =
E

n =

Ec

156

13.91

A ctr = b t 0 / n =

, (ACI 8.5.1)
in2

36.5

Actr ( d + h r + 0.5t 0 )+ 0.5 Ad


=
Actr + A

yb =

I tr

S tr =

24.7

in, from steel bottom.

2
Actr t 02
+ Actr ( 0.5t 0 + h r + d y b ) =
12

I tr = I x + A( y b 0.5d ) +

St =

in, (AISC-ASD I1.1, page 5-56)

in3, referred to steel bottom.

532

yb
I tr

( d + hr + t 0 yb )

1112

CHECK BENDING & SHEAR CAPACITIES


w = w s + w wt = 246.00

M max =

wB L 2

1610

in3, referred to concrete top.

+(

43.50

8.27

ft-kips, (changeable).

Top:

Shear:

fb =

M DL

fc =

M max

V max =

M LL

Sx

39 ksi

S tr
=

1.249

nS t

dtw

wBL

124

kips, (changeable per actual).

V max

2
297.77 lbs / ft (total gravity loads)

) =

8
Bottom:

in4

13161

<
0.9 F y =
[Satisfactory]

45

__
ksi

<

0.45 f c ' =

1.35

ksi, (non-shored, AISC-ASD I2.2, page 5-57)

ksi, (AISC-ASD I2.2, page 5-57)

[Satisfactory]

6.648

ksi

<

0.4F y =
20
ksi
[Satisfactory]
(neglecting concrete & steel deck capacity conservatively)

Page 360 of 533


524

(cont'd)
CHECK SHEAR CONNECTOR CAPACITY

'
V h = MIN 0.85 f c Ac / 2

F y As / 2 =

S eff = Min[ M max / (0.66 F y ) , S tr ] =

S eff S s
S tr S s

V 'h = MAX
0.85

wr
hr

Nr

wr
0.6
hr

in , referred to steel bottom.

, 0.25 V h =

Hs
1.0
hr

Hs
1.0
hr

q' = q =

532

646.43 kips, (AISC-ASD I4-1 & I4-2, page 5-58)

646.43 kips, (AISC-ASD I2-1 & I4, page 5-57 & 58)

, for Perpendicular

, for Parallel &

8.11

0.850

< 1.0

, (AISC-ASD I5-1, page 5-61)

wr
<1.5
hr

kips, (AISC-ASD I5.2, page 5-61)

Allowable Horizontal Shear Load for One Connector (q, kips)


(AISC-ASD Table I4.1 with coefficient Table I4.2, page 5-59)
Dia.
Concrete fc'
min. Hs
0.500
0.625
0.750

( in )
1/2
5/8
3/4

( in )
2
2 1/2
3

3.0
4.2
6.6
9.5

3.5
4.6
7.1
10.4

4.0 or Larger
4.9
7.6
11.0

2 N 1 ' = 2 V h ' / q' =

160

, total number on the beam for partical composite action.

2 N 1 = 2 V h / q' =

160

, total number on the beam for full composite action.

n = MIN[ MAX(2N 1 ' , 2N 1 /4) , 2N 1 ] =

160

, total number required on the beam, (AISC-ASD I4, page 5-59)

CHECK INITIAL DEFLECTION / CAMBER AND STRESS ON NON-COMPOSITE (AISC-ASD I2.1, page 5-56)
w DL =
DL =

100%
5 w DL L

Self Wt =

0.83

kips / ft (100% self weight load only)

0.81

in, Camber Suggested

ksi

<
0.66 F y =
[Satisfactory]

384 E I x

w DL L 2

8S x

33

ksi

CHECK LIVE LOAD DEFLECTION ON COMPOSITE (AISC-ASD I2.1 page 5-56 & page 2-249)
w LL =

3.94

I eff =

13161

LL =

5 w LL L 4
384 E I eff

kips / ft (live load only)


in4 (AISC-ASD, I4-4)

1.70

in

<
L / 360 =
[Satisfactory]

1.73

in

Note:
The STUDS SPACING must be based on actual deck ribs spacing for perpendicular to beam. For the following total [15] studs, if ribs spacing
12" o. c., the minimum composte beam capacity is from
2 rows @ 12" o.c., not one row @ 8.57" o.c. See software
CompositeFloorBeamWithCantilever.xls on the website

www.Engineering-International.com
for more information.
Technical References:
1. AISC: "Manual of Steel construction 9th", American Institute of Steel Construction, 1990.
2. Alan Williams Ph.D., S.E., C.Eng.: "Structural Steel Design - Volume 1: ASD", ICBO, 2001.

__
Page 361 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Composite Beam Design with Formed Steel Deck Based on AISC-ASD


INPUT DATA & DESIGN SUMMARY
BEAM SECTION
BEAM SPAN
BEAM SPACING (DECK SPAN)

=>

W21X62
40
ft
11
ft, o.c.
2
=
125 lbs / ft

DEAD LOAD

w DL

LIVE LOAD
RIBS PERPENDICULAR TO BEAM ?

w LL =

80
yes

lbs / ft

BEAM YIELD STRESS

Fy =

50

ksi

CONCRETE STRENGTH

fc'=

4.5

ksi

TOPPING CONCRETE THICK.

t0 =

in

5/8

in

=>

A
18.3

L =
B =

SHEAR STUD DIA. (1/2, 5/8, 3/4)

d
21.0

Ix
1330

Sx
127

(perpendicular)

NOMINAL RIB HEIGHT

hr =

in

AVERAGE WIDTH OF RIB

wr =

in

NUMBER OF STUD IN ONE RIB

Nr =

( Total 34 - 5/8 x 3.5" Shear Studs Required)


( 2 1/16 in camber suggested)

THE BEAM DESIGN IS ADEQUATE.


ANALYSIS
CHECK DIMENSION REQUIREMENTS (AISC-ASD I5.1, page 5-60)
t0 =

in

>

in

[Satisfactory]

hr =

in

<

in

[Satisfactory]

5/8

in

<

3/4

in

[Satisfactory]

H s = h r + 1.5 =
s =
15

3.5
in o.c.

in
<

2.5
in o.c.

in
[Satisfactory]
[Satisfactory]

wr =

in

>

in

[Satisfactory]

>
36
2

DETERMINE COMPOSITE PROPERTIES


b = MIN ( L / 4 , B ) =

120

in, (AISC-ASD I1.1, page 5-56)

29000
=
=
n=
E c 57 f '
c

7.58

, (ACI 8.5.1)

A ctr = b t 0 / n =

in

47.5

Actr ( d + h r + 0.5t 0 )+ 0.5 Ad


=
Actr + A

yb =

I tr = I x + A( y b 0.5d ) +
2

I tr

S tr =

St =

20.6

in, from steel bottom.

2
Actr t 02
+ Actr ( 0.5t 0 + h r + d y b ) =
12

in4

3954

in3, referred to steel bottom.

192

yb
I tr

( d + hr + t 0 yb )

733

in3, referred to concrete top.

CHECK BENDING & SHEAR CAPACITIES


lbs / ft2 (total gravity loads)
w=
205

M max =

wB L 2

451

ft-kips, (changeable).

V max =

8
Bottom:

Top:

Shear:

fb =

M DL

fc =

M max

M LL

Sx

S tr

0.974

nS t

dtw

45

kips, (changeable per actual).

V max

wBL

37 ksi

<
0.9 F y =
[Satisfactory]

45

__
ksi

<

0.45 f c ' =

2.025

ksi, (non-shored, AISC-ASD I2.2, page 5-57)

ksi, (AISC-ASD I2.2, page 5-57)

[Satisfactory]

9.127

ksi

<

0.4F y =
20
ksi
[Satisfactory]
(neglecting concrete & steel deck capacity conservatively)

Page 362 of 533


524

(cont'd)
CHECK SHEAR CONNECTOR CAPACITY

'
V h = MIN 0.85 f c Ac / 2

F y As / 2 =

S eff = Min[ M max / (0.66 F y ) , S tr ] =

S eff S s
S tr S s

V 'h = MAX

0.85

Nr

wr
hr

q' = q =

164

457.5 kips, (AISC-ASD I4-1 & I4-2, page 5-58)

in , referred to steel bottom.

, 0.25 V h =

148.62 kips, (AISC-ASD I2-1 & I4, page 5-57 & 58)

H s 1.0
hr

0.956

8.80

< 1.0

, (AISC-ASD I5-1, page 5-61)

kips, (AISC-ASD I5.2, page 5-61)

Allowable Horizontal Shear Load for One Connector (q, kips), (AISC-ASD Table I4.1, page 5-59)
Dia.
Concrete fc'
min. Hs
0.500
0.625
0.750

( in )
1/2
5/8
3/4

( in )
2
2 1/2
3

3.0
5.1
8.0
11.5

3.5
5.5
8.6
12.5

4.0 or Larger
5.9
9.2
13.3

2 N 1 ' = 2 V h ' / q' =

34

, total number on the beam for partical composite action.

2 N 1 = 2 V h / q' =

104

, total number on the beam for full composite action.

n = MIN[ MAX(2N 1 ' , 2N 1 /4) , 2N 1 ] =

34

, total number required on the beam, (AISC-ASD I4, page 5-59)

CHECK INITIAL DEFLECTION / CAMBER AND STRESS ON NON-COMPOSITE (AISC-ASD I2.1, page 5-56)
w DL =

DL =

kips / ft (dead load only)

1.38

5 w DL L

2.05

in, Camber Suggested

ksi

<
0.66 F y =
[Satisfactory]

384 E I x
f

w DL L 2

26

8S x

33

ksi

CHECK LIVE LOAD DEFLECTION ON COMPOSITE (AISC-ASD I2.1 page 5-56 & page 2-249)
w LL =

0.88

I eff =

2826

LL =

5 w LL L 4
384 E I eff

kips / ft (live load only)


4
in (AISC-ASD, I4-4)

0.62

in

<
L / 360 =
[Satisfactory]

Technical References:
1. AISC: "Manual of Steel construction 9th", American Institute of Steel Construction, 1990.
2. Alan Williams Ph.D., S.E., C.Eng.: "Structural Steel Design - Volume 1: ASD", ICBO, 2001.

__
Page 363 of 533
524

1.33

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Composite Beam Design with Verco Floor Deck Based on AISC 360-05 / IBC 09
DESIGN CRITERIA
The input STUDS SPACING must be based on actual deck ribs spacing for perpendicular to beam. For the following total [15] studs, if ribs spacing
12" o. c., the minimum composte beam capacity is from
2 rows @ 12" o.c., not one row @ 8.57" o.c.

INPUT DATA & DESIGN SUMMARY


BEAM SECTION

=>

W18X50

=>

FLOOR DECK TYPE

=>

W3-6 1/4" LW

SUPERIMPOSED LOAD, ASD

L 1 = 42.425
L 2 = 2.845
B = 9.67
w s,1 = 98.70

CONCENTRATED END LOADS


RIBS PERPENDICULAR TO BEAM ?

w s,2 = 121.33 lbs / ft2


P = 3.3845 kips
Yes (perpendicular)

BEAM SPAN
CANTILEVER (0 = no cantilever)
BEAM SPACING (TRIB. WIDTH)

d
18.0

Ix
800

Sx
88.9

Zx
101

ft
ft
ft, o.c.
lbs / ft

BEAM YIELD STRESS

Fy =

50

ksi

CONCRETE STRENGTH

fc'=

ksi

3/4
12

in
in o.c.

SHEAR STUD DIA. (1/2, 5/8, 3/4)


=
STUDS SPACING
1
row @
(Total Studs 44 + 4 )

A
14.7

THE BEAM DESIGN IS ADEQUATE.

USE C = 1 0/4" AT MID BEAM.

ANALYSIS
DETERMINE REACTIONS, MOMENTS & SHEARS
+(
43.50
w 1 = w s 1+ w wt = 98.6972148
+(

w 2 = w s, 2+ w wt = 121.327215
P=

3.3845

kips

43.50

5.17

5.17

X1 =

20.94

ft

X2 =

20.94

ft

X3 =

0.54

ft

V max = 34.00 kips, at R2 left.

M max =

312.5

ft-kips

M min = -16.282 ft-kips

) =
=

147.37
1.43

) =
=

170.00
1.64

lbs / ft

kips / ft (total gravity loads on span beam)


2
lbs / ft
kips / ft (uniform gravity loads on cantilever)

R 1 = 29.85 kips
R 2 = 38.67 kips

CHECK DIMENSION REQUIREMENTS


t0 =

3.25

in

>

in

[Satisfactory]

(AISC 360-05 I3.2c.1.c)

hr =

in

<

in

[Satisfactory]

(AISC 360-05 I3.2c.1.a)

3/4

in

3/4

in

[Satisfactory]

H s = h r + 1.5 =
s =
12
wr =

<
4.5

in

<

h r + t o - 0.5 =

in o.c.

<
>

MAX[ 8(h r + t o ) , 36 ] =
4 =
3
in o.c.

in

>

in

(AISC 360-05 I3.2c.1.b)


5.75

in

[Satisfactory]

50
in o.c.
[Satisfactory]

[Satisfactory]

(AISC I3.2c.1.b)

[Satisfactory]
(AISC 360-05 I3.2d.6)

(AISC 360-05 I3.2c.1.a)

DETERMINE COMPOSITE PROPERTIES FOR PLASTIC DESIGN


b = MIN (L / 4 , B) =
A ctr =

A fill = A - 2A f - A w =
tw =

0.36

__

116.04 in, (AISC 360-05 I3.1a)


2
19.2 in

0.85 f c ' b t 0 / F y =

0.16
in

in

Page 364 of 533


524

h = t0 + hr + d =

24.3 in, (total height)


2
in

A total = A ctr + A =

33.9
2

Af =

4.28

in

tf =

0.57

in

(cont'd)

yb =

AF y
h
for Atotal 2 Actr
'b
0.85 f c

d 0.5 Atotal Actr for Atotal 2( Actr + A f


bf
Atotal A f 0.5 A fill

tf+

y =

h
h

thus,

for Atotal 2 A ctr

0.5 t 0 A ctr + 0.5 dA + ( 0.5 A total A ctr ) h d y b

0.5 Atotal

for Atotal > 2( Actr + A f

tw

0.5 t 0 + h r + y b

21.8

for Atotal 2 A ctr + A f

in, (plastic neutral axis to bottom)

) (

0.5 t 0 Atotal + A f t 0 + h r + t f + 0.5 A fill t 0 + h r + 2 t f + t w d y b t f

)( h 0.5 d 0.5 y b + 0.5 t f ) + t w( y b t f )( 0.5 y b + 0.5 t f )

0.5 A total

y =

14.0

for Atotal > 2 A ctr + A f

in, (moment arm between centroid of tensile force and the resultant compressive force.)

Z tr = 0.5 y A total =

in

238

DETERMINE COMPOSITE PROPERTIES FOR ELASTIC DESIGN


E

n =

Ec

13.01

A ctr = b t 0 / n =

, (ACI 318-05 8.5.1)


2

in

29.0

Actr ( d + h r + 0.5t 0 )+ 0.5 Ad


=
Actr + A

yb =

I tr = I x + A( y b 0.5d ) +
2

S tr =

St =

I tr

18.0

in, (elastic neutral axis to bottom)

2
Actr t 02
+ Actr ( 0.5t 0 + h r + d y b ) =
12

2636

in4

in3, referred to steel bottom.

146

yb
I tr

( d + hr + t 0 yb )

425

in , referred to concrete top.

CHECK BENDING & SHEAR CAPACITIES


Middle Bottom :

M max = (Z tr / Z x ) M DL + M LL =
where

b =

1.67

3.76(E / F y )
Cantilever Top :

0.5

b =

1.67

90.55

>

h / tw =

Mn / b =

<

2.85

ft

L p = 1.76 ry (E / Fyf)0.5 =

5.83

ft

E
0.7 F y

M p = Fy Zx =

F cr =

Jc
S x h0

420.8

C b 2E
2

ft-kips, (AISC 360 I3.2a)

[Satisfactory]

ft-kips, (AISC 360 I3.2b)

[Satisfactory]

50.70
252.0

(AISC 360-05 I3.2b)

L b = MAX( X 3 , L 2 ) =

L r = 1.95 r ts

1+ 0.078

Lb
r ts

1+ 1+ 6.76

0.7 F y S x h 0
E

Jc

16.96

Jc
S x h0

Lb
r ts

1265.34

ksi

1.98

h0 = d - tf =

17.43

in

ry

Zx

Cb =

, (AISC 360-05 F1)

1.65

101

__
1.30

ft

ft-kips

r ts =[( Iy Cw)0.5/ Sx]0.5 =


c =
1.00

Mp
Mn =

593.0

(AISC 360-05 I3.2a)

M min = -16.28179 ft-kips


where

452.2 ft-kips

M n / b = Z tr F y / b =

<

Iy
40

G
11200

J
1.24

Cw
3040

420.83

ft-kips, for L b @ [0 , L p]

MIN{Cb [Mp - (Mp - 0.75 Fy Sx) (Lb - Lp) / (Lr - Lp)] , Mp}

N/A

ft-kips, for L b @ (L p , L r]

MIN(Fcr Sx , Mp)

N/A

ft-kips, for L b @ (L r , Larger)

Page 365 of 533


524

(cont'd)
Shear : V max =

34.00

kips

V n / v = 0.6 F y AwC v / v =

<

114.79 kips, (AISC 360-05 I3.1b)


[Satisfactory]

where

2.24 (E / F y )

0.5

kv =

(k v E / F y )

0.5

53.946
(AISC 360-05 G2.1b)

53.852

Cv =

v =

1.67

(AISC 360-05 G2.1b)


(AISC 360-05 G1)

CHECK SHEAR CONNECTOR CAPACITY


M max =

312.5

ft-kips

b =

where

Mn / b = Zx Fy / b =

>

1.67

C f = MIN ( 0.85 f c ' A c , F y A s ) =

735

S eff = Min[ M max / (0.66 F y ) , S tr ] =

114

S eff S s
S tr S s

V ' = MAX

wc =
1.5

0.5

33 (f c ')

kips, (AISC 360-05 C-I3.1)


3
in , refered to steel bottom.

, R g R p A sc F u ] =

0.5

15.37

2229.1

ksi

in

Fu =

58

ksi

Rg =

1.00

(AISC 360-05 Table I3.2b.3)

Rp =

0.60

(AISC 360-05 Table I3.2b.3)

Qn = Qn Nr X1 / s =

kips, (AISC 360-05 I3.2d.3)

pcf

0.44

A sc =

<== Shear Studs Required

, 0.25 C f = 183.75 kips, (AISC 360-05 C-I3-4)

115

Ec = wc

ft-kips

Q n = MIN [ 0.5 A sc (f c ' E c )


where

252.0

(AISC 360-05 F1 & F2-1)

321.98

kips

>

V'

[Satisfactory]

CHECK INITIAL DEFLECTION / CAMBER AND STRESS ON NON-COMPOSITE


DL =
75%
Self Weight
L = L1 =

a = L2 =

42.43 ft

P = P DL =

2.54

kips

w 1 = w DL,1 =

0.35

klf

w 2 = w DL,2 =

0.35

klf

End =

2.85 ft

P a 2 ( L + a ) w1 L 3a w 2 a 3 ( 4 L + 3a )

+
=
3EI
24 EI
24 EI

Mid =

Pa L 2 5w1 L 4 w 2 L 2 a 2
+

=
16 EI 384 EI
32 EI

1.06

-0.21

in, uplift perpendicular to beam.

in, downward perpendicular at middle of beam.


USE C = 1 0/4" AT MID BEAM.

M max =

77.4

ft-kips

<

Mn / b = Zx Fy / b =

252.0

ft-kips

-0.63

in, uplift.

[Satisfactory]

CHECK LIVE LOAD DEFLECTION ON COMPOSITE


P=
0.00
kips
w 1 = w LL,1 =

0.95

w 2 = w LL,2 =

1.17
klf
4
in (AISC 360-05 C-I3-3)

I eff =
End =

2015

klf

Pa 2 ( L + a )
w 2 a 3 ( 4 L + 3a )
w 3a
1L
+
3EI
24 EI
24 EI

<
Mid =

Pa L 2
5w1 L 4
w 2a 2
+
2L
16 E I eff
384 E I eff
32 E I eff

<

0.92

2L 2 / 240 =

0.28

in

in, downward.

L 1 / 360 =

1.41

__

in

[Satisfactory]

Technical References:
1. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.

Page 366 of 533


524

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Composite Girder Design Based on AISC 360-05 / CBC 10 / IBC 09


INPUT DATA & DESIGN SUMMARY
GIRDER SECTION

=>

W21X44

FLOOR DECK TYPE

=>

W3-6 1/4" LW

GIRDER SPAN
GIRDER SPACING (TRIB. WIDTH)
GIRDER SELF WEIGHT, ASD
NUMBER OF EQUAL POINT LOAD
EQUAL POINT LOAD, ASD
RIBS PERPENDICULAR TO GIRDER ?

=>

d
20.7

Ix
843

Sx
81.6

Zx
95.4

28
ft
L =
21
ft, o.c.
B =
w BM = 44.24 lbs / ft
2
N=
P = 30.417 kips @ 9.33" o.c.
No (parallel)

GIRDER YIELD STRESS

Fy =

50

ksi

CONCRETE STRENGTH

fc'=

ksi

3/4
18

in
in o.c.

SHEAR STUD DIA. (1/2, 5/8, 3/4)


1
STUDS SPACING

A
13

=
row @
(Total Studs 20 )

THE GIRDER DESIGN IS ADEQUATE.

ANALYSIS
DETERMINE REACTIONS, MOMENTS & SHEARS
R = 0.5 (w BM L + N P) =
31.04

kips

2
M max = 0.5 R L - 0.125 w BM L - (P D i ) =

V max = R =

31.04

288.2

ft-kips, at middle of girder

kips

CHECK DIMENSION REQUIREMENTS


t0 =

3.25

in

>

in

[Satisfactory]

hr =

in

<

in

[Satisfactory]

(AISC 360-05 I3.2c.1.a)

3/4

in

<

3/4

in

[Satisfactory]

(AISC 360-05 I3.2c.1.b)

H s = h r + 1.5 =
s =
18

in

<

in o.c.

4.5

<
>

MAX[ 8(h r + t o ) , 36 ] =
4 =
3
in o.c.

wr =

in

>

h r + t o - 0.5 =

in

(AISC 360-05 I3.2c.1.c)

5.75

in

[Satisfactory]

50
in o.c.
[Satisfactory]

[Satisfactory]

(AISC I3.2c.1.b)

[Satisfactory]
(AISC 360-05 I3.2d.6)

(AISC 360-05 I3.2c.1.a)

DETERMINE COMPOSITE PROPERTIES FOR PLASTIC DESIGN


b = MIN (L / 4 , B) =
A ctr =

84 in, (AISC 360-05 I3.1a)


2
13.9 in

0.85 f c ' b t 0 / F y =

A fill = A - 2A f - A w =
tw =

0.22

0.35

h = t0 + hr + d =

in

in

AF y
for Atotal 2 Actr
'b
0.85 f c

d 0.5 Atotal Actr for Atotal 2( Actr + A f


bf

27.0 in, (total height)


2
in

A total = A ctr + A =

26.9
2

Af =

2.93

in

tf =

0.45

in

h
yb =

tf+

0.5 t 0 + h r + y b
y =

h
h

thus,

Atotal A f 0.5 A fill

for A total 2 A ctr

0.5 t 0 A ctr + 0.5 dA + ( 0.5 A total A ctr ) h d y b

0.5 A total

for Atotal > 2( Actr + A f

tw

) (

in, (plastic neutral axis to bottom)

for A total 2 A ctr + A f

0.5 t 0 A total + A f t 0 + h r + t f + 0.5 A fill t 0 + h r + 2 t f + t w d y b t f

23.9

)( h 0.5 d 0.5 y b + 0.5 t f ) + t w( y b t f )( 0.5 y b + 0.5 t f )

__
0.5 Atotal

y =

15.1

Z tr = 0.5 y A total =

in, (moment arm between centroid of tensile force and the resultant compressive force.)
203

in3

DETERMINE COMPOSITE PROPERTIES FOR ELASTIC DESIGN


n =

E
Ec

13.01

, (ACI 318-05 8.5.1)

Page 367 of 533


524

for A total > 2 A ctr + A f

(cont'd)
A ctr = b t 0 / n =

in

21.0

Actr ( d + h r + 0.5t 0 )+ 0.5 Ad


=
Actr + A

yb =

I tr = I x + A( y b 0.5d ) +
2

S tr =

St =

I tr

19.6

in, (elastic neutral axis to bottom)

2
Actr t 02
+ Actr ( 0.5t 0 + h r + d y b ) =
12

2662

in

in3, referred to steel bottom.

136

yb
I tr

( d + hr + t 0 yb )

362

in , referred to concrete top.

CHECK BENDING & SHEAR CAPACITIES


M max = (Z tr / Z x ) M DL + M LL =

Middle Bottom :

where

b =

1.67
0.5

w deck =

43.50 lbs / ft

31.04

kips

506.6

ft-kips, (AISC 360 I3.2a)

[Satisfactory]

(AISC 360-05 I3.2a)

3.76(E / F y )

Shear : V max =

383.8 ft-kips

M n / b = Z tr F y / b =

<

90.55

>

h / tw =

59.14

V n / v = 0.6 F y AwC v / v =

<

130.15 kips, (AISC 360-05 I3.1b)


[Satisfactory]

where

0.5
=
2.24 (E / F y )

kv =

53.946
(AISC 360-05 G2.1b)

(k v E / F y ) 0.5 =

53.852

Cv =

v =

1.67

(AISC 360-05 G2.1b)


(AISC 360-05 G1)

CHECK SHEAR CONNECTOR CAPACITY


M max =
where

288.2

ft-kips

b =

Mn / b = Zx Fy / b =

>

1.67

C f = MIN ( 0.85 f c ' A c , F y A s ) =

650

S eff = Min[ M max / (0.66 F y ) , S tr ] =

105

S eff S s
S tr S s

V ' = MAX

wc =

<== Shear Studs Required

, 0.25 C f = 162.5

115

kips, (AISC 360-05 C-I3-4)


18.06

kips, (AISC 360-05 I3.2d.3)

pcf

E c = w c 1.5 33 (f c ') 0.5 =


A sc =

ft-kips

kips, (AISC 360-05 C-I3.1)


3
in , refered to steel bottom.

0.5
, R g R p A sc F u ] =
Q n = MIN [ 0.5 A sc (f c ' E c )

where

238.0

(AISC 360-05 F1 & F2-1)

0.44

2229.1 ksi
in2

Fu =

58

Rg =

1.00

(AISC 360-05 Table I3.2b.3)

ksi

Rp =

0.75

(AISC 360-05 Table I3.2b.3)

Qn = Qn Nr X1 / s =

168.59 kips

>

V'

[Satisfactory]

CHECK INITIAL DEFLECTION / CAMBER AND STRESS ON NON-COMPOSITE


DL =
75%
Self Weight
w DL =
33.18
lbs / ft
P DL =
e=

Mid

6.70
0.036

kips @ 9.33" o.c.


L=

3
e
5w DL L 4
= P DL L +
=
EI
384 EI

M max =

66.9

ft-kips

0.39

<

28.00 ft
in, downward at middle of girder.

Mn / b = Zx Fy / b =

238.0

ft-kips

CHECK LIVE LOAD DEFLECTION ON COMPOSITE


P=
23.71
kips

e P LL L 3
=
Mid =
E I tr

0.42

__
in, downward at middle of girder.

<

L / 360 =

0.93

in

Page 368 of 533


524

[Satisfactory]

[Satisfactory]

Daniel

PROJECT :
CLIENT :
JOB NO. :

Tian Li

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

WF Base Plate Design Based on AISC Manual 13th Edition (AISC 360-05)
INPUT DATA & DESIGN SUMMARY
AXIAL LOAD OF COMPRESSION

Pa =

200

kips, ASD

STEEL PLATE YIELD STRESS

Fy =

60

ksi

fc' =
3
W10X45
=>
N =
16
16
B =
A2 =
1156
AREA OF CONCRETE SUPPORT
(geometrically similar to and concentric with the loaded area.)

CONCRETE STRENGTH
COLUMN SIZE
BASE PLATE SIZE

ksi
in
in
2
in

USE
16
x
16
1 in thick plate

ANALYSIS
CHECK BEARING PRESSURE (AISC 360-05 J8)

P p / c =
Where

f 'c A1
c

A2 , 1
A1

MIN 0.85MAX

A1

256

2.50

, 1.7 =

522.24 kips

in , actual area of base plate.

DETERMINE VALUES OF m, n, n', X , and (AISC 13th Page 14-5)


m = 0.5 (N - 0.95 d) =
3.20
in
n = 0.5 (B - 0.8 b f ) =
4.79
in
n' = 0.25 (d b f )
X = MIN

= MIN
Where

0.5

2.25

4d b f

( d +b f )
2 X
1 + 16
1 X
d
bf

c P a
Pp

, 1 =

, 1 =

in
0.38

0.69

=
=

10.10
8.02

in, depth of column section.


in, flange width of column section.

DETERMINE REQUIRED THICKNESS OF BASE PLATE (AISC 13th Page 14-6)

t min = l
Where

3.33P a
=
F yBN

1.00

in

= MAX ( m, n, n' ) =

4.79

in

__
Page 369 of 533
524

>
[Satisfactory]

Pa

Daniel

PROJECT :
CLIENT :
JOB NO. :

Tian Li

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Tube Base Plate Design Based on AISC Manual 13th Edition (AISC 360-05)
INPUT DATA & DESIGN SUMMARY
AXIAL LOAD OF COMPRESSION

Pa =

200

kips, ASD

STEEL PLATE YIELD STRESS

Fy =

60

ksi

fc' =
3
ksi
HSS8X8X1/2
=>
N =
16
in
16
in
B =
2
A2 =
1156 in
AREA OF CONCRETE SUPPORT
(geometrically similar to and concentric with the loaded area.)

CONCRETE STRENGTH
COLUMN SIZE
BASE PLATE SIZE

USE
16
x
16
7/8 in thick plate

ANALYSIS
CHECK BEARING PRESSURE (AISC 360-05 J8)

P p / c =
Where

f 'c A1
c

A2 , 1
A1

MIN 0.85MAX

A1

256

2.50

, 1.7 =

522.24 kips

in , actual area of base plate.

DETERMINE VALUES OF m, n, n', X , and (AISC 13th Page 14-5)


m = 0.5 (N - 0.95 d) =
4.20
in
n = 0.5 (B - 0.95 b ) =
4.20
in
n' = 0.25 (d b ) 0.5 =
2.00
in
X = MIN

= MIN
Where

4db

( d +b )2
2 X
1+ 1 X
d
b

c P a , 1 =
Pp

, 1 =

0.38

0.69

=
=

8.00
8.00

in, depth of column section.


in, width of column section.

DETERMINE REQUIRED THICKNESS OF BASE PLATE (AISC 13th Page 14-6)

t min = l
Where

3.33P a
=
F yBN

0.87

in

= MAX ( m, n, n' ) =

4.20

in

__
Page 370 of 533
524

>
[Satisfactory]

Pa

Daniel

PROJECT :
CLIENT :
JOB NO. :

Tian Li

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Pipe Base Plate Design Based on AISC Manual 13th Edition (AISC 360-05)
INPUT DATA & DESIGN SUMMARY
AXIAL LOAD OF COMPRESSION

Pa =

200

kips, ASD

STEEL PLATE YIELD STRESS

Fy =

60

ksi

fc' =
3
ksi
HSS8.750X0.500
=>
N =
16
in
16
in
B =
2
A2 =
1156 in
AREA OF CONCRETE SUPPORT
(geometrically similar to and concentric with the loaded area.)

CONCRETE STRENGTH
COLUMN SIZE
BASE PLATE SIZE

USE
16
x
16
1 in thick plate

ANALYSIS
CHECK BEARING PRESSURE (AISC 360-05 J8)

P p / c =
Where

f 'c A1
c

A2 , 1
A1

MIN 0.85MAX

A1

256

2.50

, 1.7 =

522.24 kips

in , actual area of base plate.

DETERMINE VALUES OF m, n, n', X , and (AISC 13th Page 14-5)


m = 0.5 (N - 0.80 d) =
4.50
in
n = 0.5 (B - 0.80 d) =
4.50
in
n' = 0.25 (d b ) 0.5 =
2.19
in
X = MIN

= MIN
Where

4db

( d +b )2
2 X
1+ 1 X
d
b

c P a , 1 =
Pp

, 1 =

0.38

0.69

=
=

8.75
8.75

in, depth of column section.


in, width of column section.

DETERMINE REQUIRED THICKNESS OF BASE PLATE (AISC 13th Page 14-6)

t min = l
Where

3.33P a
=
F yBN

0.94

in

= MAX ( m, n, n' ) =

4.50

in

__
Page 371 of 533
524

>
[Satisfactory]

Pa

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Beam Connection of Conventional Configuration Based on AISC 360-2010


INPUT DATA & DESIGN SUMMARY
WF BEAM SECTION
GRAVITY SERVICE LOAD
LATERAL TENSION LOAD, ASD
PLATE THICKNESS

= > W21X50
P =
47
kips
T =
15
kips
t = 0.75 in

PLATE STEEL YIELD STRESS


TRIAL WELD SIZE
BOLT DIAMETER
BOLT MATERIAL (A307, A325, A490)
HOLE TYPE (STD, NSL, OVS, SSL, LSL)
STD =
NSL =
OVS =
SSL =
LSL =

Fy =
w=
=
ASTM =
=>

Standard round holes ( d + 1/16 " )


Long or short-slotted hole normal to load direction
Oversize round holes
Short-slotted holes
Long-slotted holes

CONNECTION TYPE (SC, N, X)


SC
N
X

36
ksi
0.5 in ( 1/2 in)
1
in ( 1 in)
A325
STD

=>

USE PLATE 8.5" x 3.0" x 3/4" WITH WELD 1/2" EACH SIDE TO
COLUMN AND 1 ROW OF TOTAL (3) - 1" BOLTS AT BEAM END.

= Slip critical connection


= Bearing-type connection with threads included in the shear plane
= Bearing-type connection with threads excluded from the shear plane

TRY BOLT NUMBERS


1
row &
IS TOP FLANGE COPED ? (1=Yes, 0=No,)

3
=>

bolts per row, (total 3 bolts.)


0
No

ANALYSIS
SECTION PROPERTIES (AISC Manual Table 1)
tf
k
d
tw
20.8
0.38
0.535
1.04
CHECK CAPACITY OF BOLTS (AISC 360-10 J3)
Allow shear per bolt

(P2 + T2 )0.5 =
No. of bolts required
Bolt spacing required
Edge spacing required
Number of rows required
Bolt group capacity

18.8

49
=
=
=
=
=

kips
2.6
3.00
1.25
1
57

kips / bolt, (Rn / v, AISC Manual Table 7)


Number of bolts used

in
in, (Tab J3.4)
rows
>
kips

>

Bolt spacing used


Edge spacing used
Number of rows used

(P2 + T2 )0.5
P =

=
47

=
=
=
=
kips

3
bolts
3.00 in
1.25 in
1
rows
49
kips
[Satisfactory]

[Satisfactory]
[Satisfactory]
[Satisfactory]
[Satisfactory]

CHECK CAPACITY OF WELDING (AISC 360-10 J2)


e
Plate thickness
Weld size,w
Min allowable weld
Max allowable weld
te
D
I = 2 ( te D3 / 12 )

=
=
=
=
=
=
=
=

1.75
0.75
0.50
0.25
0.69
0.35
8.5
36.2

in, (AISC 360-10, Table J3.4)


in
in
in
[Satisfactory]
in
[Satisfactory]
in
in
in4
=

P / Aw = P / 2 D t e

7.8

ksi

9.7

ksi

m =

0.0403 in

2.5

ksi

f(p) =

1.2563 , (AISC 360-10, J2-9)

Fw =

57.188 ksi, (AISC 360-10, J2-8)

Vertical shear =
Bending stress

= 0.5 P e D / I

Tension stress =

T / Aw = T / 2 D te

Resultant Stress = [ (P/Aw)2 + (0.5 P e D / I + T/Aw)2 ]0.5 =


Allow shear Fw / = Fw / 2.0
>

=
14.5

u =

14.5

28.6
ksi

ksi

17.7

deg, (AISC 360-10, J2-5)

0.0694 in

ksi
[Satisfactory]

CHECK PLATE FOR SHEAR CAPACITY (AISC 360-05 G2)


P/A =
7.4
ksi <
0.6 Fy Cv / v = 0.6 Fy 1.0 / 1.5 =
CHECK PLATE FOR TENSION CAPACITY (AISC 365-05 D)
T/A=
2.4
ksi <
Fy / t = Fy / 1.67 =

21.56

14.4

ksi

ksi

[Satisfactory]

[Satisfactory]

CHECK NET SHEAR FRACTURE (AISC 360-10 J4.2)


Fu
=
58
ksi ( AISC Manual, Pg. 2-39)
Pallow = 0.6 Fu / [ D - n (ds + 1/8 ) ] t

67

kips

>

47

kips

[Satisfactory]

111

kips

>

15

kips

[Satisfactory]

CHECK NET TENSION FRACTURE (AISC 360-10 J4.1)


Fu
=
58
ksi
Tallow = Fu / [ D - n (ds + 1/8 ) ] t

CHECK BLOCK SHEAR ( WEB TEAR-OUT, AISC 360-10 J4) <== Applicable only for top flange coped.
=
0.8
in
lh
lv

4.8

in

Fu

65

ksi ( for WF, AISC Manual, Pg. 2-39)

Rbs,P = 0.6 Av Fu / + At Fu / = (0.3 lv + 0.5 lh) tw Fu


[Satisfactory]
Rbs,T = (0.5 lv + 2 x 0.3 lh) tw Fu

70

>

T=

15

kips
[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Beam Connection of Extended Configuration Based on AISC 360-2010


INPUT DATA & DESIGN SUMMARY
WF BEAM SECTION
GRAVITY SERVICE LOAD
LATERAL TENSION LOAD, ASD
PLATE THICKNESS

= > W24X94
P =
43
kips
T =
155 kips
t = 0.625 in

PLATE STEEL YIELD STRESS


TRIAL WELD SIZE
BOLT DIAMETER
BOLT MATERIAL (A307, A325, A490)
HOLE TYPE (STD, NSL, OVS, SSL, LSL)
STD =
NSL =
OVS =
SSL =
LSL =

Standard round holes ( d + 1/16 " )


Long or short-slotted hole normal to load direction
Oversize round holes
Short-slotted holes
Long-slotted holes

CONNECTION TYPE (SC, N, X)


SC
N
X

50
ksi
0.5 in ( 1/2 in)
1
in ( 1 in)
A325
STD

Fy =
w=
=
ASTM =
=>

=>

USE PLATE 20.5" x 13.1" x 5/8" WITH WELD 1/2" EACH SIDE TO
COLUMN AND 2 ROW OF TOTAL (14) - 1" BOLTS AT BEAM END.

SC

= Slip critical connection


= Bearing-type connection with threads included in the shear plane
= Bearing-type connection with threads excluded from the shear plane

TRY BOLT NUMBERS


2
rows &
IS TOP FLANGE COPED ? (1=Yes, 0=No,)
EXTENDED DIMENSION

7
bolts per row, (total 14 bolts.)
0
No
=>
a = 7.11 in

ANALYSIS
SECTION PROPERTIES (AISC Manual Table 1)

d
24.3

tf
0.875

tw
0.515

k
1.38

CHECK CAPACITY OF BOLTS (AISC 360-10 J3)


Allow shear per bolt

(P2 + T2 )0.5 =
No. of bolts required
Bolt spacing required
Edge spacing required
Number of rows required
Bolt group capacity

161
=
=
=
=
=

11.5

kips
14.0
3.00
1.25
2
161

kips / bolt, (Rn / v, AISC Manual Table 7)

>
CHECK CAPACITY OF WELDING (AISC 360-10 J2)
e , (including a )
Plate thickness
Weld size,w
Min allowable weld
Max allowable weld
te
D
I = 2 ( te D3 / 12 )
Vertical shear =

P / Aw = P / 2 D t e

Bending stress

= 0.5 P e D / I

Tension stress =

T / Aw = T / 2 D te

Number of rows used

(P2 + T2 )0.5
P =

=
43

in, (AISC 360-10, Table J3.4)


in
in
in
[Satisfactory]
in
[Satisfactory]
in
in
in4
=

kips

14
bolts
3.00 in
1.25 in
2
rows
161 kips
[Satisfactory]

3.0

ksi

u =

0.0314 in

9.0

ksi

m =

0.0261 in

10.7

ksi

f(p) =

1.1321 , (AISC 360-10, J2-9)

Fw =

70.035 ksi, (AISC 360-10, J2-8)

19.9

35.0
ksi

ksi

74.495 deg, (AISC 360-10, J2-5)

ksi
[Satisfactory]

CHECK PLATE FLEXURE CAPACITY WITH VON-MISES REDUCTION (AISC Manual, page 10-103)
22.5 ksi
fv = [(P/A)2 + (T/A + 6Pe / tD2 )2 ]0.5 =
Fcr = (Fy2 - 3 fv2 )0.5 =
M = Pe =

37.1

ft-k

31.3
<

ksi

Fcr Z / =

102.5 ft-k

[Satisfactory]

CHECK PLATE FOR SHEAR CAPACITY (AISC 360-05 G2)


P/A =
3.4
ksi <
0.6 Fy Cv / v = 0.6 Fy 1.0 / 1.5 =
CHECK PLATE FOR TENSION CAPACITY (AISC 365-05 D)
T/A=
12.1
ksi <
Fy / t = Fy / 1.67 =

29.94

20

ksi

ksi

[Satisfactory]

[Satisfactory]

CHECK NET SHEAR FRACTURE (AISC 360-10 J4.2)


Fu
=
70
ksi ( AISC Manual, Pg. 2-39)
Pallow = 0.6 Fu / [ D - n (ds + 1/8 ) ] t

166

kips

>

43

kips

[Satisfactory]

276

kips

>

155

kips

[Satisfactory]

CHECK NET TENSION FRACTURE (AISC 360-10 J4.1)


=
70
ksi
Fu
Tallow = Fu / [ D - n (ds + 1/8 ) ] t

CHECK BLOCK SHEAR ( WEB TEAR-OUT, AISC 360-10 J4) <== Applicable only for top flange coped.
lh
=
2.8
in
lv
=
12.8
Fu

65

in

ksi ( for WF, AISC Manual, Pg. 2-39)

Rbs,P = 0.6 Av Fu / + At Fu / = (0.3 lv + 0.5 lh) tw Fu


Rbs,T = (0.5 lv + 2 x 0.3 lh) tw Fu

[Satisfactory]
[Satisfactory]
[Satisfactory]
[Satisfactory]

10.36
0.63
0.50
0.25
0.56
0.35
20.5
507.6

=
19.9

>

Bolt spacing used


Edge spacing used

=
=
=
=
=
=
=
=

Resultant Stress = [ (P/Aw)2 + (0.5 P e D / I + T/Aw)2 ]0.5 =


Allow shear Fw / = Fw / 2.0

=
=
=
=

Number of bolts used

in
in, (Tab J3.4)
rows
kips
>

269

>

T=

155

kips

[Satisfactory]
[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Beam to Girder Connection Design Based on AISC 360-10


INPUT DATA & DESIGN SUMMARY
WF BEAM SECTION
GRAVITY SERVICE LOAD
LATERAL TENSION LOAD, ASD
PLATE THICKNESS
PLATE STEEL YIELD STRESS
TRIAL WELD SIZE
BOLT DIAMETER
BOLT MATERIAL (A307, A325, A490)
HOLE TYPE (STD, NSL, OVS, SSL, LSL)
STD =
NSL =
OVS =
SSL =
LSL =

= > W24X94
P =
43
kips
T =
155 kips
t = 0.625 in
Fy =
50
ksi
w=
0.5
in ( 1/2 in)
I =
1
in ( 1 in)
ASTM = A325
=>
STD

Standard round holes ( d + 1/16 " )


Long or short-slotted hole normal to load direction
Oversize round holes
Short-slotted holes
Long-slotted holes

CONNECTION TYPE (SC, N, X)


SC
N
X

USE PLATE 20.5" x 7.5" x 5/8" WITH WELD 1/2" EACH SIDE TO
GIRDER WEB AND 2 ROW OF TOTAL (14) - 1" BOLTS AT BEAM END.

SC

=>

= Slip critical connection


= Bearing-type connection with threads included in the shear plane
= Bearing-type connection with threads excluded from the shear plane

TRY BOLT NUMBERS


2
rows &
IS TOP FLANGE COPED ? (1=Yes, 0=No,)
EXTENDED DIMENSION

7
bolts per row, (total 14 bolts.)
=>
1
Yes
2
in
a =

ANALYSIS
SECTION PROPERTIES (AISC Manual Table 1)

d
24.3

tw
0.515

tf
0.875

k
1.38

CHECK CAPACITY OF BOLTS (AISC 360-10 J3)


Allow shear per bolt
2

2 0.5

(P + T )
=
No. of bolts required
Bolt spacing required
Edge spacing required
Number of rows required

11.5

161
=
=
=
=

kips
14.0
3.00
1.25
2

161

Bolt group capacity


CHECK CAPACITY OF WELDING (AISC 360-10 J2)
e , (including a )
Plate thickness
Weld size,w
Min allowable weld
Max allowable weld
te
D
3
I = 2 ( te D / 12 )
Vertical shear =

P / Aw = P / 2 D te

Bending stress

= 0.5 P e D / I

Tension stress =

T / Aw = T / 2 D te

kips / bolt, (Rn / :v , AISC Manual Table 7)

4.75
0.63
0.50
0.25
0.56
0.35
20.5
507.6

Number of rows used

(P2 + T2 )0.5
P =

=
43

kips

14
3.00
1.25
2

bolts
in
in
rows

161
kips
[Satisfactory]

74.495 deg, (AISC 360-10, J2-5)

3.0

ksi

'u =

0.0314 in

4.1

ksi

'm =

0.0261 in

10.7

ksi

f(p) =

1.1321 , (AISC 360-10, J2-9)

Fw =

70.035 ksi, (AISC 360-10, J2-8)

2 0.5

=
15.1

15.1

35.0
ksi

ksi

ksi
[Satisfactory]

CHECK PLATE FLEXURE CAPACITY WITH VON-MISES REDUCTION (AISC Manual, page 10-103)
fv = [(P/A)2 + (T/A + 6Pe / tD2 )2 ]0.5 =
17.1 ksi
Fcr = (Fy2 - 3 fv 2 )0.5 =
M = Pe =

17.0

ft-k

40.3
<

ksi

Fcr Z / : =

132.0 ft-k

[Satisfactory]

CHECK PLATE FOR SHEAR CAPACITY (AISC 360-05 G2)


P/A =
3.4
ksi <
0.6 Fy Cv / :v = 0.6 Fy 1.0 / 1.5 =
CHECK PLATE FOR TENSION CAPACITY (AISC 365-05 D)
T/A=
12.1
ksi <
Fy / :t = Fy / 1.67 =

29.94

20

ksi

ksi

[Satisfactory]

[Satisfactory]

CHECK NET SHEAR FRACTURE (AISC 360-10 J4.2)


Fu
=
70
ksi ( AISC Manual, Pg. 2-39)
Pallow = 0.6 Fu / : [ D - n (ds + 1/8 ) ] t

166

kips

>

43

kips

[Satisfactory]

276

kips

>

155

kips

[Satisfactory]

CHECK NET TENSION FRACTURE (AISC 360-10 J4.1)


=
70
ksi
Fu
Tallow = Fu / : [ D - n (ds + 1/8 ) ] t

CHECK BLOCK SHEAR ( WEB TEAR-OUT, AISC 360-10 J4) <== Applicable only for top flange coped.
lh
=
2.8
in
lv
=
12.8
Fu

65

in

ksi ( for WF, AISC Manual, Pg. 2-39)

Rbs,P = 0.6 Av Fu / : + At Fu / : = (0.3 l v + 0.5 l h) tw Fu


Rbs,T = (0.5 l v + 2 x 0.3 l h) tw Fu

[Satisfactory]
[Satisfactory]
[Satisfactory]
[Satisfactory]

in, (AISC 360-10, Table J3.4)


in
in
in
[Satisfactory]
in
[Satisfactory]
in
in
in4
T=

>

Bolt spacing used


Edge spacing used

>
>

kips

=
=
=
=
=
=
=
=

Resultant Stress = [ (P/Aw) + (0.5 P e D / I + T/Aw) ]


Allow shear Fw / : = Fw / 2.0

=
=
=
=

Number of bolts used

in
in, (Tab J3.4)
rows

269

>

=
>
T=

174
P=
155

kips
43.00 kips
kips

[Satisfactory]
[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Drag Connection Based on AISC 360-05 & AISC 341-05


INPUT DATA & DESIGN SUMMARY
DRAG BEAM SECTION

=>

W27X94

COLUMN SECTION

=>

W27X217

GRAVITY SERVICE LOAD


LATERAL DRAG LOAD, ASD

P =
T =

71
245

kips
kips

PLATE THICKNESS

tp =

STIFF. THICKNESS (OPTION)

t st =

0.625 in
0

in

PLATE STEEL YIELD STRESS


WELD SIZE
DIMENSIONS

Fy =
w=
L=
D=
c=
b=

50
0.5
15
23
5
2

ksi
in
in
in
in
in

THE DESIGN IS ADEQUATE


ANALYSIS
BEAM SECTION PROPERTIES (AISC 13th Table 1)
d
26.9

tw
0.49

k
1.34

A
27.7

CHECK PLATE CAPACITY (AISC 360-05, D2 & G2)


Tn / t = Fy tp D / 1.67 =
Vn / v = 0.6 Cv Fy tp D / 1.5 =
Where

Cv =

430

kips

>

[Satisfactory]

288

kips

>

[Satisfactory]

<

d-2k-2w=

23.22

<

wmax = 0.56

in

[Satisfactory]

>

wmin =

in

[Satisfactory]

1.0

CHECK DIMENSION "D " LIMITATION


D=
23
in

in

[Satisfactory]

CHECK FILLET WELD TO WEB (AISC 360-05, J2.2b)


w=

e=
Ix =

0.5

in

10.84
4311

0.25

in, eccentricity from column face.


in4 / in
Iy =

fx = T / A + P e (0.5 D) / (Ix + Iy) =

18.9

ksi

fy = P / A + P e (e - 0.5) / (Ix + Iy) =

8.5

ksi

fv = (fx + fy)0.5 =

20.7

ksi

731

in4 / in

Fv = 0.6 FEXX / =

<

21.0

ksi

[Satisfactory]

CHECK BLOCK SHEAR ( WEB TEAR-OUT, AISC 360-05 J4)


Fu =

65

ksi ( for WF, AISC Manual 13th Edition, Pg. 2-39)

Rn / = (0.5 Lv + 2 x 0.3 Lh) tw Fu =

557

kips

>

[Satisfactory]

CHECK BEAM TENSION CAPACITY (AISC 360-05, D2)


Tn / t = (50 ksi) A / 1.67 =

829

kips

>

[Satisfactory]

>

[Satisfactory]

CHECK STIFF PLATE COMPRESSION CAPACITY (AISC 358-05, E)


Pn,st / c = Fcr A / 1.67 =
Where K =
0.75
bst =
hst = dc - 2k =

357.3 kips

__

in, one side stiff width

I = tst (2bst + twc) 3 / 12 + D twc3 / 12 =


A = 2bsttst + 25(twc)
rst = ( I / A )0.5 =

K hst / rst < 200

17

in4

c = (K hst / rst) (Fy / E)0.5 =


(Fy/Fe)

in

0.25 in

(Only top stiffeners used conservatively)

Page 374 of 533


524

(AISC 360, E2)

Fe = 2 E / (K hst / rst)2 =

23.82 in, stiff depth

Fcr =

(0.658

0.877 Fe =

[Satisfactory]

57.066 ksi, (AISC 360, E3)


2.94

)Fy =

34.65
N/A

, c

4.71

kis, for c > 4.71

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Corner Bracing Connection Capacity Based on AISC Manual 13th Edition (AISC 360-05)
DESIGN CRITERIA

For a new TYPICAL detail of bracing connection or existing bracing connection, the interface dimensions of and may
not satisfy the basic relationship of the original Uniform Force Method: - tan = eb tan - ec. This software can determine corner
gusset dimensions based on geometry and can check the gusset interface weld capacities with moment loads.

INPUT DATA & DESIGN SUMMARY


T=

250

ANGLE BETWEEN BRACE & COLUMN

25

ANGLE BTW BRACE & GUSSET EDGE

20

BRACE SECTION (Tube or Pipe)


Tube

=>

kips

HSS8X8X5/8

rmin

16.40

2.98

0.63

8.00

8.00

=>

W12X96

x-x

, ec =

=>

W16X67

x-x

, eb =

COLUMN SECTION
ORIENTATION =
BEAM SECTION
ORIENTATION =

BRACE AXIAL LOAD AT SERVICE LEVEL

6.35

in

8.15

in

THE CONNECTION DESIGN IS ADEQUATE.


( 1" Gusset Plate with 5/8" Fillet Weld, 4 leg x 8" Length at Brace,
and 2 leg x 27" at Column Interface, 2 leg x 15" at Beam Interface. )

ANALYSIS
DETERMINE BEST FILLET WELD SIZE PER BRACE THICKNESS (AISC 360-05 J2.2b)
wMIN =
w=
0.625
in
>
0.25 in
( USE w =

0.625

<
wMAX = ( 0.6 Fu t) / ( 0.707 FEXX) = (0.75 x 0.6 x 58 ksi) t / (0.75 x 0.707 x 70 ksi)
[Satisfactory]
= 1.1795 t =
0.74 in

in )

5/8

DETERMINE REQUIRED WELD LENGTH AT BRACE (AISC 360-05 J2.4 )


L = T / [(4) (0.6) FEXX (0.707 w)]
= (2.0) (250.00) / [(4) (0.6) (70) (0.707 x 5/8)] =

6.74

in

( USE L =

DETERMINE REQUIRED THICKNESS OF GUSSET PLATE PER Tt,rup,brace ABOVE (AISC 360-05 Tab. J2.4)
tg =

in

( USE tg =

DETERMINE GUSSET DIMENSIONS BASED ON GEOMETRY


2=
Lg =
22.3
in
26.8

in

2=

in )

14.6

in

DETERMINE CONNECTION INTERFACE FORCES ( AISC Manual 13th Edition, Page 13-10)
=
13.39 in
=
7.32
in
>
(eb + ) tan - ec =
3.69

in
[The original Uniform Force Method may not apply]

-2.55

in

2
2
D = tan + ( / ) =
K' = ( tan + / ) =

0.5166
7.4191

Ideal = (K' tan + K ( / )2 ) / D =


Ideal = (Ideal - K) / tan =

5.22
16.66

r = [(eb + Ideal)2 + (ec + Ideal)2] 0.5 =


Vc = (Ideal / r) T =

152.2

Hc = (ec / r) T =

58.0

Mc = Hc [ Ideal - ] =
74.4

Hb = (Ideal / r) T =

47.7

Mb = Vb [ Ideal - ] =

27.38

in

kips

__
kips

15.8

Vb = (eb / r) T =

in

in

K = eb tan - ec =

ft-kips

kips

kips

-13.0

ft-kips

CHECK WELD CAPACITY AT INTERFACES (AISC 360-05 J2.4 )


fVc = Vc / (4 0.707 w) =
6.43
ksi

Page 375 of 533


524

8.00
8

in )

(cont'd)
fHc = Hc / (4 0.707 w) =

2.45

ksi

fMc = 3 Mc / (4 0.707 w) =

1.80

ksi

fVb = Vb / (4 0.707 w) =

5.75

ksi

fHb = Hb / (4 0.707 w) =

3.68

ksi

2
fMb = 3 Mb / (4 0.707 w) =
=
2.0

4.95

ksi

7.71

ksi

2 0.5

fv,c = [(fvc) + (fHc+ fMc) ]


2

2 0.5

fv,b = [(fvb) + (fHb + fMb) ]

10.38

<
<

ksi

0.6 FEXX / =

21.00 ksi

[Satisfactory]

0.6 FEXX / =

21.00 ksi

[Satisfactory]

CHECK SHEAR RUPTURE CAPACITY OF SLOTTED BRACE (AISC 360-05 J4.2)


Rn,rup,brace/ =(0.6Fu)Anu / =
Where

Fu =

58

348

kips
>
[Satisfactory]

ksi ( AISC Manual 13th Edition, Pg. 2-39)

Anu = 4 t L = 4 x 0.625 x 8 =
=
2.0

20.00

in2

CHECK SHEAR RUPTURE CAPACITY OF GUSSET PLATE (AISC 360-05 J4.2)


Rn,rup,gusset/ = (0.6Fu)Anv / = 278.4 kips
Where

Fu =

58

>

16.00

in2

[Satisfactory]

ksi (A36 Steel)

Anv = 2 tg L = 2 x 1 x 8 =
=
2.0

CHECK TENSION CAPACITY AT SLOTTED BRACE (AISC 360-05 J4.1)


Rt Rn/ = Rt Fu Ae/ =
=
Where
Fu =

353.29
2
58

kips

>

[Satisfactory]

ksi ( AISC Manual 13th Edition, Pg. 2-335)

B2+2BH / 4(B+H) = 3.00 , for Tube (AISC Tab. D3.1)


D / = 2.55 , for Pipe (AISC 360 Tab. D3.1)
U = MIN( 1 - x / L , 0.9 ) =
0.63
,(AISC Tab D3.1)
2
An = Ag - 2 (tg + 1/8) t =
14.99 in

x =

Ae =

U An =

9.37

in2

Rt =
1.3
(AISC 341-05 6.2)
Try Cover Plate
0
x
7
, at Each Sides.
(0 for no cover required)
xA
x
Region
0.5 An
HSS
Cover Plate

3.00
4.00

7.50
0.00

22.49
0.00

7.50

22.49

x = 22.49 / 7.50 =
3.00
U = MIN( 1 - x / L , 0.9 ) =
0.63
2
An = 14.99 + 0.00 =
14.99 in
Ae = U An =

Thus, t Rn/ = Rt Fu Ae/ =

353.29

kips

>

9.37

in2

[Satisfactory]

CHECK GUSSET BLOCK SHEAR CAPACITY (AISC 360-05 J4.3)


Rn,guss/ = Min [0.6FuAnv , 0.6FyAgv] / + UbsFuAnt/ =

278.4

>

T=

__
Page 376 of 533
524

+ UbsFuAnt/
250.0

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Bracing Connection Capacity at Middle of Beam Based on AISC Manual 13th Edition (AISC 360-05)

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


BRACE AXIAL LOAD AT SERVICE LEVEL

ANGLE BETWEEN BRACE & BEAM

T-1 =
T-2 =

250
-230

-1=

35

-2=

65

20

ANGLE BTW BRACE & GUSSET EDGE


BRACE SECTION (Tube or Pipe)
Tube

=>

kips
kips

HSS8X8X5/8

rmin

16.40

2.98

0.63

8.00

8.00

=>

W16X67

x-x

, eb =

BEAM SECTION
ORIENTATION =

8.15

in

( 1" Gusset Plate with 5/8" Fillet Weld, 4 leg x 8" Length at Brace,
and 2 leg x 42" at Beam Interface. )

THE CONNECTION DESIGN IS ADEQUATE.


ANALYSIS
DETERMINE GUSSET DIMENSIONS BASED ON GEOMETRY
Case B
2=
10.19
in
2 ( - 1) = 27.34
in
2 ( - 2) = 13.73
in
Lg =
W=

15.86
13.82

in, the max buckling length


in, the Whitmore width

DETERMINE BEST FILLET WELD SIZE PER BRACE THICKNESS


(AISC 360-05 J2.2b)
w=
0.625
( USE w = 0.625

in
in )

>
<

wMIN =

0.25

in

wMAX = ( 0.6 Fu t) / ( 0.707 FEXX) = (0.75 x 0.6 x 58 ksi) t / (0.75 x 0.707 x 70 ksi)
[Satisfactory]
= 1.1795 t =
0.74 in

5/8

DETERMINE REQUIRED WELD LENGTH AT BRACE (AISC 360-05 J2.4 )


L = T / [(4) (0.6) FEXX (0.707 w)]
= (2.0) (250.00) / [(4) (0.6) (70) (0.707 x 5/8)] =

6.74

in

( USE L =

8.00
8

in )

DETERMINE REQUIRED THICKNESS OF GUSSET PLATE PER Tt,rup,brace ABOVE (AISC 360-05 Tab. J2.4)
tg =

in

( USE tg =

in )

DETERMINE CONNECTION INTERFACE FORCES ( AISC Manual 13th Edition, Page 13-10)
=
0
in
5.10
in
ec =

-1=

13.67

in

-2=

5.71

in

K = eb tan - ec =

7.6824
46.227

D = tan2 + ( / )2 =
K' = ( tan + / ) =

6.87

in

For T-1
K = eb tan - ec =

For T-2

2
2
D = tan + ( / ) =
K' = ( tan + / ) =

__

Ideal = (K' tan + K ( / ) ) / D =


2

Ideal = (Ideal - K) / tan =

9.56

5.50

2
2 0.5
r = [(eb + Ideal) + (ec + Ideal) ] =

Vc = (Ideal / r) T =

82.5

Hc = (ec / r) T =

0.0

Mc = Hc [ Ideal - ] =

in

16.66

kips

kips
0.0

in

ft-kips

in

17.48

in
6.4145
23.981

Ideal = (K' tan + K ( / ) ) / D =

12.96

Ideal = (Ideal - K) / tan =

in

-2.10

r = [(eb + Ideal)2 + (ec + Ideal)2] 0.5 =

Vc = (Ideal / r) T =

33.8

Hc = (ec / r) T =

0.0

Mc = Hc [ Ideal - ] =

Page 377 of 533


524

14.30

kips
kips
0.0

ft-kips

in
in

(cont'd)
Vb = (eb / r) T =

122.3

kips

Vb = (eb / r) T =

-131.0

kips

Hb = (Ideal / r) T =

143.4

kips

Hb = (Ideal / r) T =

-208.5

kips

Mb = Vb [ Ideal - ] =

-41.9

Mb = Vb [ Ideal - ] =

ft-kips

-66.6

ft-kips

CHECK WELD CAPACITY AT INTERFACES (AISC 360-05 J2.4 )


V=
8.7
kips
H=
351.8
kips
M=
27.1
ft-kips
fVb = V / (4 0.707 w) =

0.36

ksi

fHb = H / (4 0.707 w) =

14.56

ksi

fMb = 3 M/ (4 0.707 w) =
=
2.0

2.96

ksi

fv,b = [(fvb)2 + (fHb + fMb)2] 0.5 =

17.53

ksi

<

0.6 FEXX / =

21.00 ksi

[Satisfactory]

CHECK SHEAR RUPTURE CAPACITY OF SLOTTED BRACE (AISC 360-05 J4.2)


Rn,rup,brace/ =(0.6Fu)Anu / =
Where

Fu =

58

348

kips
>
[Satisfactory]

ksi ( AISC Manual 13th Edition, Pg. 2-39)

Anu = 4 t L = 4 x 0.625 x 8 =
=
2.0

20.00

in2

CHECK SHEAR RUPTURE CAPACITY OF GUSSET PLATE (AISC 360-05 J4.2)


Rn,rup,gusset/ = (0.6Fu)Anv / = 278.4 kips
Where

Fu =

58

>

16.00

in

[Satisfactory]

ksi (A36 Steel)

Anv = 2 tg L = 2 x 1 x 8 =
=
2.0

CHECK TENSION CAPACITY AT SLOTTED BRACE (AISC 360-05 J4.1)


Rt Rn/ = Rt Fu Ae/ =
=
Where
Fu =

353.29
2
58

kips

>

[Satisfactory]

ksi ( AISC Manual 13th Edition, Pg. 2-335)

B2+2BH / 4(B+H) = 3.00 , for Tube (AISC Tab. D3.1)


D / = 2.55 , for Pipe (AISC 360 Tab. D3.1)
U = MIN( 1 - x / L , 0.9 ) =
0.63
,(AISC Tab D3.1)
2
An = Ag - 2 (tg + 1/8) t =
14.99 in

x =

Ae =

U An =

9.37

in2

Rt =
1.3
(AISC 341-05 6.2)
Try Cover Plate
0
x
7
, at Each Sides.
(0 for no cover required)
xA
x
Region
0.5 An
HSS
Cover Plate

3.00
4.00

7.50
0.00

22.49
0.00

7.50

22.49

x = 22.49 / 7.50 =
3.00
U = MIN( 1 - x / L , 0.9 ) =
0.63
2
An = 14.99 + 0.00 =
14.99 in
Ae = U An =

Thus, t Rn/ = Rt Fu Ae/ =

353.29

kips

>

9.37

in2

[Satisfactory]

CHECK GUSSET BLOCK SHEAR CAPACITY (AISC 360-05 J4.3)


Rn,guss/ = Min [0.6FuAnv , 0.6FyAgv] / + UbsFuAnt/ =

278.4

>

T=

__
Page 378 of 533
524

+ UbsFuAnt/
250.0

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Corner Gusset Plate Dimensions Generator

INPUT DATA
ANGLE BTW BRACE & GUSSET EDGE
BRACE SECTION (Tube or Pipe)

=>
Tube

COLUMN SECTION

=>

ORIENTATION =

y-y

HSS8X8X5/8
h = 8.00
( USE h = 8.00

ORIENTATION =

ANALYSIS

in
in )

0.28

in )

=>

W18X65

x-x

, eb =

9.2

in

( USE eb =

9.20

in )

1
15

19.31
30.50

in, the interface dimension between gusset and column


in, the interface dimension between gusset and beam

Lg =
W=

18.24
25.32

in, the average buckling length


in, the Whitmore width

9.65

in

15.25

in

in
in

2=
2=

=
=

, ec = 0.275 in

tg =
L=

THICKNESS OF GUSSET PLATE


WELD LENGTH AT BRACE

W12X96
( USE ec =

BEAM SECTION

= 44.72
=
30

ANGLE BETWEEN BRACE & COLUMN

<
(eb + ) tan - ec =
18.39
in, ( AISC Manual 13th Edition, Page 13-10)
[The original Uniform Force Method may not apply]

__
Page 379 of 533
524

PROJECT :
CLIENT :
JOB NO. :

DATE :

Middle of Beam Gusset Plate Dimensions Generator

INPUT DATA
ANGLE BETWEEN BRACE & BEAM
ANGLE BTW BRACE & GUSSET EDGE
BRACE SECTION (Tube or Pipe)

=>
Tube

BEAM SECTION

=>

ORIENTATION =

x-x

-1=

35

-2=

65

25

HSS8X8X5/8
h = 8.00
( USE h = 8.00

in
in )

W21X68
, eb = 10.55 in
( USE eb = 10.55 in )
tg =
L=

THICKNESS OF GUSSET PLATE


WELD LENGTH AT BRACE

1
10

in
in

ANALYSIS
Case B
2=
11.81
2 ( - 1) = 34.35
2 ( - 2) = 17.13

in
in
in

Lg =
W=

in, the max buckling length


in, the Whitmore width

18.80
17.33

__
Page 380 of 533
524

PAGE :
DESIGN BY :
REVIEW BY :

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Check Capacity of WF Beam at Opening Based on AISC 360-05


INPUT DATA & DESIGN SUMMARY
WF SECTION
MOMENT @ ABCD SECTION

MABCD

=>
=

MOMENT @ EFGH SECTION


MAX SHEAR @ OPENING

MEFGH
V

=
=

75
60

ft-k
kips

Fy
w

=
=

50
1/4

ksi
in

BEAM YIELD STRESS


TRIAL WELD SIZE

W24x76
90
ft-k

OPENING DIMENSIONS

b
h

=
=

48
10

in
in

OPENING LOCATION
PLATE SIZE @ EACH SIDE

e
t

=
=

8
0.75

in
in

4.25

in

USE (4) - 3/4" x 4-1/4" x 7' -2" PLATES, WITH WELD 1/4" AT EACH SIDES, TOP & BOTTOM.

ANALYSIS
DATA FOR ROLLED SECTION CHOSEN
A

tw

bf

tf

Sx

Fb = Fy / b = Fy / 1.67 =

22.4

23.9

0.44

8.99

0.68

176

Fv = 0.6 Fy / v = 0.6 Fy / 1.67 =

y1b
3.88

y2t
2.87

y2b
3.03

A top
15.7

V top
34.53

V bott
25.47

Ms,top
69.1

Ms,bott
50.9

29.94

ksi, (AISC 360-05, F1 & F5)


17.96

ksi, (AISC 360-05, G2)

PROPERTIES OF OPENING SECTION


t
0.75

y1t
4.12

4.25

Y1
12.2

A bott
14.8

Y2
11.7

I top
173

I bott
89

I total
2,398

CHECK BENDING STRESSES

MAIN BENDING STRESSES

1
1
1
1
1
1
1
1

-5.51
-1.91
2.59
5.25
-4.59
-1.59
2.16
4.38

SECONDARY BENDING STRESSES

2
2
2
2
2
2
2
2

ksi
ksi
ksi
ksi
ksi
ksi
ksi
ksi

Max f b

DETERMINE STIFFENER EXTENSIONS


Max bending stress f b @ stiffener
Force, F
=
8.5
x
Allow stress in web
Extension =
143.4
/
(

Max

-19.17
19.17
-20.34
20.34
19.17
-19.17
20.34
-20.34

( 1+2 )

0.75

22.50

0.44

17.96

TOTAL BENDING STRESSES

( 1+2 )
( 1+2 )
( 1+2 )
( 1+2 )
( 1+2 )
( 1+2 )
( 1+2 )
( 1+2 )

ksi
ksi
ksi
ksi
ksi
ksi
ksi
ksi

25.59

=
=
=
=

22.5
143.4
17.96
18.1
19.0

Say =>
CHECK WELDING
Weld width, w =

0.25

V top

Q top

I top

q top

q critical

34.53

23.5

173

4.70

te = 0.707w

in

Min weld =

Q bott
22.3

I bott
89

q bott
6.40

in

=
=
=

Max weld
6.40

k / in

0.18

in

9.05

ksi

29.94

0.69

Page 381 of 533


524

ksi

-24.68
17.26
-17.74
25.59
14.57
-20.76
22.50
-15.96

ksi
ksi
ksi
ksi
ksi
ksi
ksi
ksi

[Satisfactory]

in

Fv = 0.6 Fu / = 0.6 x 70 ksi / 2.0 =


[Satisfactory]

<

ksi
k
ksi
in
in

__

q / 4 te
V bott
25.47

0.25

<

ksi

21.00
ksi
(AISC 360-05, J4.2)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Weld Capacity of Eccentric Connection Based on AISC 360-05


INPUT DATA & DESIGN SUMMARY
THICKER PART JOINTED
WELD SIZE
GRAVITY LOAD, ASD
ECCENTRICITY TO EDGE
LATERAL LOAD, ASD

t =
w=
P=
e =
F=

WELD LENGTH, DA

L1 =

in

WELD LENGTH, DC

L2 =

18

in

WELD LENGTH, CB

L3 =

in

0.75
0.25
10.7
30
5

in
in
kips
in
kips

THE CONNECTION DESIGN IS ADEQUATE.


ANALYSIS
MIN WELD SIZE (AISC 360-05 Tab. J2.4)

wmin =

0.25 in

MAX WELD SIZE (AISC 360-05 J2.2b)

wmax =

0.69 in

EFFECTIVE THROAT THICKNESS


CENTROID OF WELD GROUP
CENTRODIAL MOMENT OF INERTIA
TOTAL ECCENTRICITY

te =

0.707 w

0.18

in

X0 =

Xi Ai / Ai

0.42

in

Y0 =

Yi Ai / Ai

9.75

in

Ix =

(b h3/ 12 + A d2 )

169

in4

Iy =

(b h3/ 12 + A d2 )

in4

e + L1 - X0

33.6

in

e total, P =
e total, F =
Fv =

ALLOWABLE STRESS (AISC 360-05 J2.4 )

0.5 L2 - Y0

-0.8

in

0.6 FEXX /

21.0

ksi

DETERMINE SHEAR STRESS @ POINTS A, B, C, D


Point A : fx = F / Aw + M yA / (Ix + Iy) =

18.1 ksi

fy = -P / Aw - M xA / (Ix + Iy) =

-9.9 ksi

Point B : fx = F / Aw - M yB / (Ix + Iy) =

-18.9 ksi

fy = -P / Aw - M xB / (Ix + Iy) =

-5.8 ksi

Point C : fx = F / Aw - M yC / (Ix + Iy) =

-18.9 ksi

fy = -P / Aw + M xC / (Ix + Iy) =

-1.7 ksi

Point D : fx = F / Aw + M yD / (Ix + Iy) =

18.1 ksi

fy = -P / Aw + M xD / (Ix + Iy) =

-1.7 ksi

CHECK SHEAR CAPACITY @ POINTS A, B, C, D


Point A : fv = (fx2 + fy2)0.5 =
2

2 0.5

Point B : fv = (fx + fy )

20.7 ksi

19.7 ksi

Point C : fv = (fx2 + fy2)0.5 =

18.9 ksi

Point D : fv = (fx2 + fy2)0.5 =

18.2 ksi

<
<
<
<

Fv =

21.0

ksi

[Satisfactory]

Fv =

21.0

ksi

[Satisfactory]

Fv =

21.0

ksi

[Satisfactory]

Fv =

21.0

ksi

[Satisfactory]

__
Page 384 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Weld Capacity of Eccentric Connection Based on AISC 360-05


INPUT DATA & DESIGN SUMMARY
THICKER PART JOINTED
WELD SIZE
ECCENTRICITY TO EDGE
WELD LENGTH
GRAVITY LOAD, ASD
LATERAL LOAD, ASD

t = 0.75 in
w = 0.375 in
x =
6
in
D=
10
in
P=
29
kips
5
kips
F=

THE CONNECTION DESIGN IS ADEQUATE.


ANALYSIS
MIN WELD SIZE (AISC 360-05 Tab. J2.4)

w min = 0.25 in

MAX WELD SIZE (AISC 360-05 J2.2b)

w max = 0.69 in

EFFECTIVE THROAT THICKNESS

te=

0.707 w

CENTRODIAL MOMENT OF INERTIA

Ix=

2 (t e D3 / 12 )

DIRECT SHEAR STRESS

fx=

F/2Dte

=
=

fy=

P/2Dte

BENDING STRESS

fx=

DPx/2Ix

RESULTANT STRESS

fv=

ALLOWABLE STRESS (AISC 360-05 J2.4 )

0.27

[( f x)2 + f y2 ) 0.5 =
Fv =

in

=
0.9

in4

20.7

ksi

ksi

5.5

ksi

19.7

ksi

20.7

ksi

0.6 FEXX /

>

44.2

=
fv =

21.0

__
Page 385 of 533
524

ksi
[Satisfactory]

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Design of 1 1/2" Type "B" Roof Deck Based on ICBO ER-2078P


INPUT DATA & DESIGN SUMMARY
NO. OF SPANS (1,2 or 3)
DECK VERT. SPAN LENGTH

n =
=

GAGE (22,20,18,16) ? =>


DEAD LOAD
LIVE LOAD
DIAPHRAGM HORIZ SPAN
DIAPHRAGM HORIZ DEPTH

== >
DL
LL
L
d

THE MAX DIAPHRAGM SHEAR


NO. OF SUPPORT WELD (4, 5 or 7)
SPACING OF PUDDLE WELD
SIDE LAP TYPE (0=BP, 1=TSW)
SPACING OF SIDELAP CONNECTION

2
9

USE:
1 1/2" x 20 GA. VERCO PLB-36/HSB-36 GALVANIZED ROOF DECK

ft

=
=
=
=

20
20
20
150
50

v =

680

plf

5
12
1
12

per sheet
in o.c.
Top Seam Weld
in o.c.

== >
== >

( 2 SPANS MINS)
5 -1/2 " PUDDLE WELDS PER SHEET, EACH SUPPORT.
1/2" PUDDLE WELD @ 12" O.C. EACH PARALLEL SUPPORT.
SIDELAP TOP SEAM WELD (TSW) @ 12" O.C.

GA

psf
psf
ft
ft

(THE DIAPHRAGM DEFLECTION, 0.69 in, AT MIDDLE SPAN.)

ANALYSIS
PLB & HSB SECTION PROPERTIES (ER-2078P, Table 4, page 3)
3

PUDDLE WELDS ALLOWABLE DIAPHRAGM SHEAR (ER-2078P, Table 1, page 2)

GAGE

thk, in

I, in4/ft

+S, in /ft

-S, in /ft

Wt, psf

GAGE

6" o.c.

9" o.c.

12" o.c.

18" o.c.

16

0.0598

0.377

0.411

0.417

3.5

16

4186

2791

2093

1395

18

0.0478

0.302

0.322

0.335

2.9

18

3346

2231

1673

1115

20

0.0359

0.216

0.235

0.248

2.3

20

2513

1675

1257

838

22

0.0299

0.175

0.187

0.198

1.9

22

2093

1395

1047

698

10

11

12
12'-0"

HSB-36 ALLOWABLE DIAPHRAGM SHEAR, q (plf), AND FLEXIBILITY FACTORS, F (ER-2078P, Table 20, page 40-47)
SUPPORT

GAGE

BP

4'-0"

5'-0"

6'-0"

7'-0"

8'-0"

9'-0"

10'-0"

11'-0"

36/5

20

24

690

675

590

516

447

405

361

334

36/5

20

24

4.0+91R

5.1+73R

6.5+61R

8.2+52R

10.4+45R

12.8+40R

15.9+36R

19.0+33R

23.1+30R

36/5

20

12

762

733

656

568

501

450

408

374

346

36/5

20

12

3.9+91R

4.9+73R

6.1+61R

7.7+52R

9.5+45R

11.7+40R

14.3+36R

17.2+33R

20.6+30R

36/5

20

24

991

872

730

679

598

572

518

504

465

36/5

20

24

20.5+43R

18.2+34R

23.7+28R

21.5+24R

26.2+21R

24.1+19R

28.3+17R

26.3+16R

30.2+14R

36/5

20

18

1084

941

788

727

680

608

583

561

518

36/5

20

18

13.4+43R

13.4+34R

17.2+28R

16.6+24R

16.3+21R

19.4+19R

18.8+17R

18.5+16R

21.1+14R

36/5

20

12

1169

1006

895

816

756

709

672

641

615

36/5

20

12

10.0+43R

10.6+34R

11.0+28R

11.4+24R

11.8+21R

12.1+19R

12.4+17R

12.6+16R

12.8+14R

36/5

20

1469

1293

1174

1088

1023

972

931

818

688

36/5

20

5.4+43R

5.5+34R

5.6+28R

5.7+24R

5.8+21R

5.9+19R

5.9+17R

6.0+16R

6.0+14R

20.72

TSW

CHECK VERTICAL BENDING CAPACITY

fb =

0.125 wl 2
, for Simple Span
+S
2
0.125 wl
, for Double Spans
S
0.1wl 2
, for Triple Spans
S

ksi, (Vero PunchLok Book, page 5.)


<

Fb

[Satisfactory]

Where w = (DL + Wt) + LL =


42
psf
Fb =
22.8 ksi, (Vero PunchLok Book, page 4.)
CHECK VERTICAL DEFLECTION

0.013wLL l 4C d
, for Simple Span
EI
4
0.0054 wLLl C d
, for Double Spans
LL =
EI
0.0069 wLLl 4C d
, for Triple Spans
EI
Where wLL =
Cd =
E=

0.19

in, (Vero PunchLok Book, page 5.)

<

20
1728

psf, as given
, (Vero PunchLok Book, page 5.)

29500

ksi, , (from ER-2078P, page 6)

/ 240 =

0.45

in

[Satisfactory]

CHECK HORIZONTAL DIAPHRAGM SHEAR CAPACITY


v=

680

plf, as given

<

vallow =

<

vallow =

709
1257

plf, (for 36/5 & TSW from table above.)


plf, ( for Puddle Weld from table above.)

__

[Satisfactory]
[Satisfactory]

DETERMINE HORIZONTAL DIAPHRAGM DEFLECTION

5w L 4(12 )
w L 2F
+
6
384 EI
8(10 ) d
3

= f + w =

0.0600

0.6316

Where w = 2 d v / L =
453
plf
R = (4 - n) / 3 =
0.667
, (from ER-2078P, page 39 footnotes.)
F=
12.1+19R
=
24.77
, for TSW connection.
2
A=
16.2 in , steel chord member area.
2
2
2916000 in , (ER-2078 page 6)
= 0.5 A d =

Page 386 of 533


524

0.6916

50

in, (from ER-2078P, page 6)

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

DEPRESSED FLOOR DECK CAPACITY USING STEEL PROPERTIES ONLY (NON COMPOSITE)
DEAD LOAD

DL =

70

psf (including partitions)

LIVE LOAD

LL =

50

psf (non-reducible)

SPAN LENGTH
GAGE (22, 20, 18, 16)
DECK TYPE (B, W2, W3, N)
DEFLECTION LIMIT OF LIVE LOAD

L=
GA =
TYPE =

8
ft
18
W2
LL = L / 240
THE DEPRESSED FLOOR DECK IS ADEQUATE.

SECTION PROPERTIES & ALLOWABLE REACTIONS (See Tables below)


+S (in3/ft)
-S (in3/ft)
I (in4/ft)
Fb
Type
Gage
W2

18

0.555

0.51

0.511

22.8

0.960

ft-kips/ft

2" end (lbs/ft)

3" end

4" end

3" mid

4" mid (lbs/ft)

533

613

693

1587

1807

0.969

ft-kips/ft

[Satisfactory]

ft-kips/ft

[Satisfactory]

For one span,


Mmax =
Rend,max =

0.125 (DL+LL) L2 =
480

4
max,DL+LL = 5 (DL+LL) L / (384 EI) =

max,LL =

5 (LL) L4 / (384 EI) =

For two spans, uniform LL on one span


0.0070 (DL) L2 + 0.096 (LL) L2 =
Mmax =
Rend,max =

385

Mallowable = Fb (+S) =

lbs/ft ( 2 in bearing length required at end )


0.7

in ( L / 140 )

0.3

in ( L / 335 )

[Satisfactory]

Mallowable = Fb (+S) =

0.621

lbs/ft ( 2 in bearing length required at end )

Rmid,max =

4
max,DL+LL = (0.00541DL + 0.0092LL) L / (EI) =

0.4

in ( L / 260 )

( 0.0092LL) L4 / (EI) =

0.2

in ( L / 475 )

max,LL =

For two spans, all spans loaded


-0.125 (DL+LL) L2 =
-Mmax =
Rend,max =

360

-0.960

max,LL =

( 0.0054LL) L4 / (EI) =

For three spans, LL partial loaded


- (0.100 DL+0.117 LL) L2 =
- Mmax =
Rend,max =

384

-0.822

max,LL =

0.3

in ( L / 336 )

0.1

in ( L / 807 )

0.0099 (LL) L4 / (EI) =

1200

0.4

in ( L / 223 )

0.2

in ( L / 441 )

Rmid,max =

-0.969

ft-kips/ft

[Satisfactory]

lbs/ft ( 3 in bearing length required at mid )

[Satisfactory]

- Mallowable = Fb (-S) =

ft-kips/ft

lbs/ft ( 2 in bearing length required at end )

4
max,DL+LL = (0.0069DL + 0.0099LL) L / (EI) =

Rmid,max =

0.969

lbs/ft ( 3 in bearing length required at mid )

[Satisfactory]

-Mallowable = Fb (-S) =

ft-kips/ft

lbs/ft ( 2 in bearing length required at end )

4
max,DL+LL = 0.00541(DL + LL) L / (EI) =

950

592

-0.969

ft-kips/ft

[Satisfactory]

lbs/ft ( 3 in bearing length required at mid )

[Satisfactory]

B SECTION PROPERTIES (ER-2078P, Table 4)


+S (in3/ft)
-S (in3/ft)
I (in4/ft)
Gage
16
0.377
0.411
0.417
18
0.302
0.322
0.335
20
0.216
0.235
0.248
22
0.175
0.187
0.198

N SECTION PROPERTIES (ER-2078P, Table 4)


I (in4/ft)
+S (in3/ft) -S (in3/ft)
Gage
16
1.647
0.950
1.005
18
1.223
0.731
0.776
20
0.837
0.508
0.562
22
0.655
0.394
0.454

W2 SECTION PROPERTIES (ER-2078P, Table 4)


+S (in3/ft)
-S (in3/ft)
I (in4/ft)
Gage
16
0.694
0.639
0.639
18
0.555
0.510
0.511
20
0.423
0.361
0.370
22
0.340
0.283
0.287

W3 SECTION PROPERTIES (ER-2078P, Table 4)


I (in4/ft)
+S (in3/ft) -S (in3/ft)
Gage
16
1.509
0.960
0.960
18
1.203
0.767
0.767
20
0.896
0.534
0.564
22
0.718
0.418
0.444

B ALLOWABLE REACTION, lbs/ft (ER-2078P, Table 5)


Gage
2" end
3" end
4" end
3" mid
16
2208
2484
2761
4789
18
1226
1407
1588
3062
20
665
784
903
1790
22
487
585
683
1250

4" mid
5268
3551
2118
1498

N ALLOWABLE REACTION, lbs/ft (ER-2078P, Table 5)


Gage
2" end
3" end
4" end
3" mid
16
1670
1879
2088
4033
18
916
1051
1186
2695
20
486
572
659
1582
22
349
419
489
1104

4" mid
4532
3066
1828
1287

W2 ALLOWABLE REACTION, lbs/ft (ER-2078P, Table 5)


Gage
2" end
3" end
4" end
3" mid
16
981
1105
1229
2380
18
533
613
693
1587
20
301
355
409
972
22
219
263
306
684

4" mid
2677
1807
1123
797

W3 ALLOWABLE REACTION, lbs/ft (ER-2078P, Table 5)


Gage
2" end
3" end
4" end
3" mid
16
942
1062
1181
2309
18
507
583
659
1528
20
268
316
365
877
22
190
228
267
601

4" mid
2597
1740
1014
701

__
Page 387 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

8-Bolted Stiffened End Plate for SMF Based on AISC 341-10, 358-10, 360-10 & FEMA-350
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION

=>

W14X211

A
62

d
15.7

tw
0.98

bf
tf
15.80
1.56
= > W21X62

Sx
338

Ix
2660

rx
6.55

ry
4.08

Zx
390

k
2.16

A
18.3

d
21.0

tw
0.40

bf
8.24

Sx
127

Ix
1330

rx
8.53

ry
1.77

Zx
144

k
1.12

BEAM SECTION

tf
0.62

STRUCTURAL STEEL YIELD STRESS

Fy =

50

ksi

THE SMRF DESIGN IS ADEQUATE.

THE FACTOR GRAVITY LOAD ON THE BEAM

wu =

4.2

klf

(Continuity column stiffeners 5/8 x 7

THE FACTOR AXIAL LOAD ON THE COLUMN


BEAM LENGTH BETWEEN COL. CENTERS
AVERAGE STORY HEIGHT OF ABOVE & BELOW
=
BOLTS
in
1 5/8
GRADES (A325 or A490)
A325

Pu =
L=
h=

800
30
12

kips
ft
ft

with 7/16" fillet weld to web & CP to flanges.


A doubler plate is not required. )

PLATE & SHIM

tp =

1 5/8

NUMBER COLUMNS

Nc =

NUMBER BEAM

Nb =
1
(One Side Only)

in

2
(Top & Bot)

ANALYSIS

g =Max( bbf - , tw + 3 ) =

6.00

in

Pb = 3 =

3.75

in (AISC 358 Tab 6.1)

Pf = 1.5 =

2.00

in (AISC 358 Tab 6.1)

Sh = dc / 2 + tp + 1" + (2Pf + Pb - 1") tan-1 30o


= 22.17 in
c = 2 Pf + tbf =
4.62
in
bp = g + 3 =

<

10.88

in

bcf

[Satisfactory]

CHECK BEAM LOCAL BUCKLING LIMITATIONS (AISC 341-10 Tab. D1.1)


bf / (2tf ) =

6.70

0.3 (Es / Fy)0.5 =

<

Where

7.22

Es =

[Satisfactory]

29000 ksi

h / tw = 46.90 <
2.45 (Es / Fy)0.5 =
59.00
CHECK COLUMN LOCAL BUCKING LIMITATIONS (AISC 341-10 Tab. D1.1)
bf / (2tf ) =
h / tw =

5.06

0.3 (Es / Fy)0.5 =

<

11.61

<

[Satisfactory]

7.22

[Satisfactory]

[Satisfactory]

3.76(Es/Fy)0.5(1-2.75Pu/bPy) =

N/A

, for Pu/bPy 0.125

1.12(Es/Fy)0.5(2.33-Pu/bPy) =

55.11

, for Pu/bPy > 0.125

Where b =

0.9

, Py = FyA =

3100

kips

CHECK BEAM - COLUMN RATIO REQUIREMENT (AISC 341-10 Sec. E3.4a)


Mpc* / (Mpb* ) =
2.59
>
1.00
[Satisfactory]
Where

Mpc* = Nc Zc (Fyc - Pu / Ag ) =

2411 ft-kips

Mpb* = Nb (Mhinge + Mv) =

930 ft-kips, at center of column

Mv = Vhinge Sh = [2Mhinge /(L-2Sh)+wu(L-2Sh)/2] Sh=


Mhinge = CprRyFyb Zb =

726

204

ft-kips

ft-kips

Ry =

1.1

(AISC 341-10 Tab. A3.1)

Cpr =

1.1

(FEMA Sec. 3.5.5.1)

CHECK BENDING MOMENT AT THE COLUMN FACE (FEMA Sec. 3.6.2.1.2)


Mf = Mhinge + [2Mhinge / (L - 2Sh) + wu(L - 2Sh)/2] (Sh - dc /2)
=
Where

858

ft-kips

<

d0 = db + Pf - 0.5 tbf =
di = d0 - c - Pb =

14.33

Ffu = Mf / ( db - tbf ) =
Tub =

114.9

>

3.4 Tub (d0 + di ) =


22.69

1205

in

in
504.93

ft-kips

Tb =

103

Abt =

1.28

[Satisfactory]
kips, (AISC 360-10, Tab. J3.1)
in2 / bolt

kips

kips, (FEMA Sec. 3.6.2.1.2)


0.591

(0.00002305 Pf

2.583

Ffu

0.895

/ (tp

1.909

dbt

0.327

tbw

0.965

bp

) + Tb =

114.5

kips

(Cont'd)

CHECK SHEAR CAPACITY AT THE COLUMN FACE (FEMA Sec. 3.6.2.1.3)


in2
Ab =
1.28
>
[2 Mf / (L - dc) + Vg ] / 6Fv =
Where

Vg = wu (L - dc) / 2 =

60.3

Fv = Fnv =

0.56

[Satisfactory]

kips

36

ksi, (AISC 360-10, Tab. J3.2)

CHECK END PLATE THICKNESS (FEMA Sec. 3.6.2.1.4)


1.625 in
>
tp =
0.9

Max[ 0.00609 Pf

0.6

0.9

Ffu / (dbt

0.1

tbw

0.7

0.25

bp ) , 0.00413 Pf

0.15

0.7

Ffu / (dbt

CHECK CONTINUITY PLATE REQUIREMENT (FEMA Sec. 3.6.2.1 & 3.3.3.1)


0.5
0.48 in
tcf, reqD = {m Ffu C3 / [0.9 Fyc (3.5 pb + c)]} =

0.15

tbw

<

0.3

bp

1.29518 in
[Satisfactory]

)] =

tcf, actual

0.60 in
<
tcw, actual
(The continuity plates may not be required.)
Ca =
1.45
, (FEMA Sec. 3.6.2.1.5 )
C3 = g / 2 - dbt / 4 - kc =
0.4338 in

tcw, reqD = Mf / [( db - tbf )( 6 kc + 2 tp + tbf) Fyc] =


Where

m = Ca (Af / Aw )

1/3

1/4

C3 / dbt

0.8309

, (FEMA Sec. 3.6.2.1.5 )

tst = tbf for interior connection, or (tbf /2) for exterior connection =
bst =

<

in

cPn,st = cFcr A =
Where

0.56 (E / Fyst )

0.5

tst =

0.62

in,

9.93

in, (AISC 358-10 Eq 6.10-10)


[Satisfactory]

USE

0.63

in, ( 5/8 in )

413.0 kips

c =

0.9

K =

0.75

,(AISC 360 E1)

I = tst (2bst + twc) 3 / 12 =

156

in4

A = 2bsttst + 25(twc) 2 =

13

in2

rst = ( I / A )0.5 =

3.49 in

Pu,st = Ryb Fyb bfb tfb =

278.7 kips

The best fillet weld size (AISC 360 Sec.J2.2b)


> wMIN =
w=
7/16
in
< wMAX =

<

cPn,st

0.25

in

0.5625

in

hst = dc - 2kc =

11.38

K hst / rst < 200

(AISC 360 E2)

in

Fe =

47926

ksi (AISC 360 E3)

Fcr =

35.99

ksi (AISC 360 E3)

Fyst =

36

[Satisfactory]

kips, plate yield stress

[Satisfactory]

[Satisfactory]
The required weld length between A36 continuity plates and column web (FEMA Fig 3-6)
Lw = 0.6tstLnstFy / [(2) Fw (0.707 w)]
Where

Lnet = dc - 2(kc + 1.5) =

= (0.625 x 8.4) x 36 / [(2) 0.75 (0.6x70)(0.707x7/16)] =

<

8.4

4.42

in

2(Lnet -0.5) [Satisfactory]

(Use complete joint penetration groove welds between continuity plates & column flanges.)
CHECK PANEL ZONE THICKNESS REQUIREMENT (AISC 341 Sec. E3.6e & FEMA Sec. 3.3.3.2)
tReqD = MAX (t1, t2) =

0.80

in

t1 = Cy Mc (h - db ) / [0.9 (0.6) Fyc Ryc dc (db - tfb) h] =


Where

Cy = Sb / (Cpr Zhing) =

0.80

Sb = 2Ib / db =

127
in4

in2

930

ft-kips

Ib = Ix =

1330

Mc = Mpb* =

t2 = (dz + wz ) / 90 = (db -2tst + dc - 2kc) / 90 =


Since twc =
not required.

0.98

in

>

0.80

in

0.35

in

tReqD ,

a doubler plate is

Technical References:
1. AISC 341-10: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, 2010.
2. AISC 358-10: "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications",
American Institute of Steel Construction, 2010.
3. AISC 360-10: "Specification for Structural Steel Buildings", American Institute of Steel Construction, 2010.
4. FEMA 350: "Recommended Seismic Design Criteria for New Steel Moment-frame Buildings.", SAC Joint Venture, 2000.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

4-Bolted Stiffened End Plate for SMF Based on AISC 341-10, 358-10, 360-10 & FEMA-350
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION

=>

W12X106

A
31.2

d
12.9

tw
0.61

bf
tf
12.20
0.99
= > W18X50

Sx
145

Ix
933

rx
5.47

ry
3.11

Zx
164

k
1.59

A
14.7

d
18.0

tw
0.36

bf
7.50

Sx
88.9

Ix
800

rx
7.38

ry
1.65

Zx
101

k
0.97

BEAM SECTION

tf
0.57

STRUCTURAL STEEL YIELD STRESS

Fy =

50

ksi

THE SMRF DESIGN IS ADEQUATE.

THE FACTOR GRAVITY LOAD ON THE BEAM

wu =

4.2

klf

(Continuity column stiffeners 5/8 x 6

THE FACTOR AXIAL LOAD ON THE COLUMN


BEAM LENGTH BETWEEN COL. CENTERS
AVERAGE STORY HEIGHT OF ABOVE & BELOW
=
BOLTS
in
1 3/4
GRADES (A325 or A490)
A325

Pu =
L=
h=

800
30
12

kips
ft
ft

with 5/16" fillet weld to web & CP to flanges.


A doubler plate is required with thickness of 3/16 in. )

PLATE & SHIM

tp =

3/4

NUMBER COLUMNS

Nc =

2
(Top & Bot)

NUMBER BEAM

Nb =
1
(One Side Only)

in

ANALYSIS

g =Max( bbf - , tw + 3 ) =
Pf = 1.5 =

2.00

5.86

in

in (AISC 358 Tab 6.1)

Sh = dc / 2 + tp + 1" + (2Pf - 1") tan-1 30o


= 13.40 in
c = 2 Pf + tbf =
4.57
in
bp = g + 3 =

<

11.11

in

bcf

[Satisfactory]

CHECK BEAM LOCAL BUCKLING LIMITATIONS (AISC 341-10 Tab. D1.1)


bf / (2tf ) =

6.58

0.3 (Es / Fy)0.5 =

<

Where

Es =

7.22

[Satisfactory]

29000 ksi

h / tw = 45.23 <
2.45 (Es / Fy)0.5 =
59.00
CHECK COLUMN LOCAL BUCKING LIMITATIONS (AISC 341-10 Tab. D1.1)
bf / (2tf ) =
h / tw =

6.16

0.3 (Es / Fy)0.5 =

<

15.93

<

[Satisfactory]

7.22

[Satisfactory]

[Satisfactory]

3.76(Es/Fy)0.5(1-2.75Pu/bPy) =

N/A

, for Pu/bPy 0.125

1.12(Es/Fy)0.5(2.33-Pu/bPy) =

47.48

, for Pu/bPy > 0.125

Where b =

0.9

, Py = FyA =

1560

kips

CHECK BEAM - COLUMN RATIO REQUIREMENT (AISC 341-10 Sec. E3.4a)


Mpc* / (Mpb* ) =
1.08
>
1.00
[Satisfactory]
Where

Mpc* = Nc Zc (Fyc - Pu / Ag ) =

666 ft-kips

Mpb* = Nb (Mhinge + Mv) =

615 ft-kips, at center of column

Mv = Vhinge Sh = [2Mhinge /(L-2Sh)+wu(L-2Sh)/2] Sh=


Mhinge = CprRyFyb Zb =

509

106

ft-kips

ft-kips

Ry =

1.1

(AISC 341-10 Tab. A3.1)

Cpr =

1.1

(FEMA Sec. 3.5.5.1)

CHECK BENDING MOMENT AT THE COLUMN FACE (FEMA Sec. 3.6.1.1.2)


Mf = Mhinge + [2Mhinge / (L - 2Sh) + wu(L - 2Sh)/2] (Sh - dc /2)
=
Where

564

ft-kips

<

d0 = db + Pf - 0.5 tbf =
di = d0 - c =

15.15

Ffu = Mf / ( db - tbf ) =
Tub =

123.7

>

2 Tub (d0 + di ) =
19.72

in

in
388.43

719

ft-kips

Tb =

103

Abt =

1.37

[Satisfactory]
kips, (AISC 360-10, Tab. J3.1)
in2 / bolt

kips

kips, (FEMA Sec. 3.6.1.1 & 3.6.2.1.2)


(0.00002305 Pf0.591 Ffu2.583 / (tp0.895 dbt1.909 tbw0.327 bp0.965) + Tb =

113.3

kips

(Cont'd)

CHECK SHEAR CAPACITY AT THE COLUMN FACE (FEMA Sec. 3.6.1.1.3)


in2
Ab =
1.37
>
[2 Mf / (L - dc) + Vg ] / 3Fv =
Where

Vg = wu (L - dc) / 2 =
Fv = Fnv =

60.7
36

0.92

ksi, (AISC 360-10, Tab. J3.2)

CHECK END PLATE THICKNESS (AISC 358-10 Eq 6.10-13)


0.5
in
0.75
>
[1.11 Mf / d Fyp Yp)] =
tp =
Where

Yp =

1258

Fyp =

36

[Satisfactory]

kips

0.41

in

[Satisfactory]

in, (AISC 358-10 Tab. 6.3 Case 1)


ksi

d =

1.0

CHECK CONTINUITY PLATE REQUIREMENT (AISC 358-10 Eq 6.10-13, FEMA Sec 3.3.3.1)
0.5
0.31 in
<
tcf, actual
tcf, reqD = [1.11 Mf / d Fyc Yc)] =
Where

Yc =

1595

in, (AISC 358-10 Tab. 6.5 Stiffened)

in
>
tcw, actual
(The continuity plates required.)
for interior connection, or (tbf /2) for exterior connection =
0.57
in,

tcw, reqD = Mf / [( db - tbf )( 6 kc + 2 tp + tbf) Fyc] =


tst = tbf
bst =

<

in

cPn,st = cFcr A =
Where

0.67

0.56 (E / Fyst )

tst =

9.93

USE

0.63

in, ( 5/8 in )

in, (AISC 358-10 Eq 6.10-10)


[Satisfactory]

345.0 kips

c =

0.9

K =

0.75

,(AISC 360 E1)

I = tst (2bst + twc) 3 / 12 =

98

in4

A = 2bsttst + 25(twc) 2 =

11

in2

rst = ( I / A )

0.5

0.5

3.04 in

Pu,st = Ryb Fyb bfb tfb =

235.1 kips

The best fillet weld size (AISC 360 Sec.J2.2b)


> wMIN =
w=
5/16
in
< wMAX =

<

cPn,st

0.1875

in

0.4375

in

hst = dc - 2kc =

9.72

K hst / rst < 200

(AISC 360 E2)

in

Fe =

49670

ksi (AISC 360 E3)

Fcr =

35.99

ksi (AISC 360 E3)

Fyst =

36

[Satisfactory]

kips, plate yield stress

[Satisfactory]

[Satisfactory]
The required weld length between A36 continuity plates and column web (FEMA Fig 3-6)
Lw = 0.6tstLnstFy / [(2) Fw (0.707 w)]
Where

Lnet = dc - 2(kc + 1.5) =

= (0.625 x 6.7) x 36 / [(2) 0.75 (0.6x70)(0.707x5/16)] =

<

6.7

4.61

in

2(Lnet -0.5) [Satisfactory]

(Use complete joint penetration groove welds between continuity plates & column flanges.)
CHECK PANEL ZONE THICKNESS REQUIREMENT (AISC 341 Sec. E3.6e & FEMA Sec. 3.3.3.2)
tReqD = MAX (t1, t2) =

0.77

in

t1 = Cy Mc (h - db ) / [0.9 (0.6) Fyc Ryc dc (db - tfb) h] =


Where

Cy = Sb / (Cpr Zhing) =

0.80

Sb = 2Ib / db =

89
in4

in2

615

ft-kips

Ib = Ix =

800

Mc = Mpb* =

t2 = (dz + wz ) / 90 = (db -2tst + dc - 2kc) / 90 =


Since twc =
0.61
required with thickness of 3/16 in.

in

<

0.77

in

0.29

in

tReqD ,

a doubler plate is

Technical References:
1. AISC 341-10: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, 2010.
2. AISC 358-10: "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications",
American Institute of Steel Construction, 2010.
3. AISC 360-10: "Specification for Structural Steel Buildings", American Institute of Steel Construction, 2010.
4. FEMA 350: "Recommended Seismic Design Criteria for New Steel Moment-frame Buildings.", SAC Joint Venture, 2000.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

4-Bolted Unstiffened End Plate for SMF Based on AISC 341-10, 358-10, 360-10 & FEMA-350
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION

=>

W12X96

A
28.2

d
12.7

tw
0.55

bf
tf
12.20
0.90
= > W18X35

Sx
131

Ix
833

A
10.3

d
17.7

tw
0.30

bf
6.00

Sx
57.6

Ix
510

BEAM SECTION

rx
5.43

ry
3.09

Zx
147

k
1.50

<== Err. See AISC 385-10 Table 6.1, no section work!

tf
0.43

rx
7.04

ry
1.22

Zx
67

k
0.83

STRUCTURAL STEEL YIELD STRESS

Fy =

50

ksi

THE SMRF DESIGN IS ADEQUATE.

THE FACTOR GRAVITY LOAD ON THE BEAM

wu =

4.2

klf

(Continuity column stiffeners 7/16 x 6

THE FACTOR AXIAL LOAD ON THE COLUMN


BEAM LENGTH BETWEEN COL. CENTERS
AVERAGE STORY HEIGHT OF ABOVE & BELOW
=
BOLTS
1 1/16 in
GRADES (A325 or A490)
A325

Pu =
L=
h=

800
30
12

kips
ft
ft

with 1/4" fillet weld to web & CP to flanges.


A doubler plate is not required. )

PLATE & SHIM

tp =

3/4

NUMBER COLUMNS

Nc =

2
(Top & Bot)

NUMBER BEAM

Nb =
1
(One Side Only)

in

ANALYSIS

g =Max( bbf - , tw + 3 ) =
Pf = 1.5 =

1.75

5.00

in

in (AISC 358 Tab 6.1)

Sh = dc / 2 + tp + db / 3
=
c = 2 Pf + tbf =
bp = g + 3 =

<

13.00
3.93

in
in

9.00

in

bcf

[Satisfactory]

CHECK BEAM LOCAL BUCKLING LIMITATIONS (AISC 341-10 Tab. D1.1)


bf / (2tf ) =

7.06

0.3 (Es / Fy)0.5 =

<

Where

Es =

7.22

[Satisfactory]

29000 ksi

h / tw = 53.49 <
2.45 (Es / Fy)0.5 =
59.00
CHECK COLUMN LOCAL BUCKING LIMITATIONS (AISC 341-10 Tab. D1.1)
bf / (2tf ) =
h / tw =

6.78

0.3 (Es / Fy)0.5 =

<

17.64

<

[Satisfactory]

7.22

[Satisfactory]

[Satisfactory]

3.76(Es/Fy)0.5(1-2.75Pu/bPy) =

N/A

, for Pu/bPy 0.125

1.12(Es/Fy)0.5(2.33-Pu/bPy) =

45.84

, for Pu/bPy > 0.125

Where b =

0.9

, Py = FyA =

1410

kips

CHECK BEAM - COLUMN RATIO REQUIREMENT (AISC 341-10 Sec. E3.4a)


Mpc* / (Mpb* ) =
1.25
>
1.00
[Satisfactory]
Where

Mpc* = Nc Zc (Fyc - Pu / Ag ) =

530 ft-kips

Mpb* = Nb (Mhinge + Mv) =

425 ft-kips, at center of column

Mv = Vhinge Sh = [2Mhinge /(L-2Sh)+wu(L-2Sh)/2] Sh=


Mhinge = CprRyFyb Zb =

335

89

ft-kips

ft-kips

Ry =

1.1

(AISC 341-10 Tab. A3.1)

Cpr =

1.1

(FEMA Sec. 3.5.5.1)

CHECK BENDING MOMENT AT THE COLUMN FACE (FEMA Sec. 3.6.1.1.2)


Mf = Mhinge + [2Mhinge / (L - 2Sh) + wu(L - 2Sh)/2] (Sh - dc /2)
=
Where

381

ft-kips

<

d0 = db + Pf - 0.5 tbf =
di = d0 - c =

15.31

Ffu = Mf / ( db - tbf ) =
Tub =

75.1

>

2 Tub (d0 + di ) =
19.24

in

in
264.67

432

ft-kips

Tb =

51

Abt =

0.83

[Satisfactory]
kips, (AISC 360-10, Tab. J3.1)
in2 / bolt

kips

kips, (FEMA Sec. 3.6.1.1 & 3.6.2.1.2)


(0.00002305 Pf0.591 Ffu2.583 / (tp0.895 dbt1.909 tbw0.327 bp0.965) + Tb =

62.9

kips

(Cont'd)

CHECK SHEAR CAPACITY AT THE COLUMN FACE (FEMA Sec. 3.6.1.1.3)


in2
Ab =
0.83
>
[2 Mf / (L - dc) + Vg ] / 3Fv =
Where

Vg = wu (L - dc) / 2 =
Fv = Fnv =

60.8
36

0.81

ksi, (AISC 360-10, Tab. J3.2)

CHECK END PLATE THICKNESS (AISC 358-10 Eq 6.10-13)


0.5
in
0.75
>
[1.11 Mf / d Fyp Yp)] =
tp =
Where

[Satisfactory]

kips

Yp =

864

in, (AISC 358-10 Tab. 6.2)

Fyp =

36

ksi

d =

0.40

in

[Satisfactory]

1.0

CHECK CONTINUITY PLATE REQUIREMENT (AISC 358-10 Eq 6.10-13, FEMA Sec 3.3.3.1)
0.5
0.41 in
<
tcf, actual
tcf, reqD = [1.11 Mf / d Fyc Yc)] =
Where

Yc =

594

in, (AISC 358-10 Tab. 6.5 Unsiffened)

0.48 in
<
tcw, actual
(The continuity plates may not be required.)
for interior connection, or (tbf /2) for exterior connection =
0.43
in,
USE

tcw, reqD = Mf / [( db - tbf )( 6 kc + 2 tp + tbf) Fyc] =


tst = tbf
bst =

<

in

cPn,st = cFcr A =
Where

0.56 (E / Fyst )

0.5

tst =

6.95

0.44

in, ( 7/16 in )

in, (AISC 358-10 Eq 6.10-10)


[Satisfactory]

242.9 kips

c =

0.9

K =

0.75

,(AISC 360 E1)

I = tst (2bst + twc) 3 / 12 =

68

in4

A = 2bsttst + 25(twc) 2 =

in2

rst = ( I / A )

0.5

3.01 in

Pu,st = Ryb Fyb bfb tfb =

140.3 kips

The best fillet weld size (AISC 360 Sec.J2.2b)


> wMIN =
w=
1/4
in
< wMAX =

<

cPn,st

0.1875

in

0.3125

in

hst = dc - 2kc =

9.7

K hst / rst < 200

(AISC 360 E2)

in

Fe =

48920

ksi (AISC 360 E3)

Fcr =

35.99

ksi (AISC 360 E3)

Fyst =

36

[Satisfactory]

kips, plate yield stress

[Satisfactory]

[Satisfactory]
The required weld length between A36 continuity plates and column web (FEMA Fig 3-6)
Lw = 0.6tstLnstFy / [(2) Fw (0.707 w)]
Where

Lnet = dc - 2(kc + 1.5) =

= (0.4375 x 6.7) x 36 / [(2) 0.75 (0.6x70)(0.707x1/4)] =

<

6.7

4.02

in

2(Lnet -0.5) [Satisfactory]

(Use complete joint penetration groove welds between continuity plates & column flanges.)
CHECK PANEL ZONE THICKNESS REQUIREMENT (AISC 341 Sec. E3.6e & FEMA Sec. 3.3.3.2)
tReqD = MAX (t1, t2) =

0.54

in

t1 = Cy Mc (h - db ) / [0.9 (0.6) Fyc Ryc dc (db - tfb) h] =


Where

Cy = Sb / (Cpr Zhing) =

0.79

Sb = 2Ib / db =

58
in4

in2

425

ft-kips

Ib = Ix =

510

Mc = Mpb* =

t2 = (dz + wz ) / 90 = (db -2tst + dc - 2kc) / 90 =


Since twc =
not required.

0.55

in

>

0.54

in

0.29

in

tReqD ,

a doubler plate is

Technical References:
1. AISC 341-10: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, 2010.
2. AISC 358-10: "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications",
American Institute of Steel Construction, 2010.
3. AISC 360-10: "Specification for Structural Steel Buildings", American Institute of Steel Construction, 2010.
4. FEMA 350: "Recommended Seismic Design Criteria for New Steel Moment-frame Buildings.", SAC Joint Venture, 2000.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

8-Bolted Moment Connection Based on AISC 341-10, 358-10, 360-10 & FEMA-350
DESIGN CRITERIA
THE NON-SEISMIC MOMENTION CONNECTION HAS RELEASED BEAM & COLUMN SECTION LIMITS, BEAM-COLUMN RATIO
REQUIREMENT, AND BENDING MOMENT AT THE COLUMN FACE FROM MEMBER CAPACITY TO ACTUAL BEAM END FORCE.
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION
A
62

=>

d
15.7

tw
0.98

W14X211

bf
tf
15.80
1.56
= > W21X62
bf
tf
8.24
0.62
Mf =

BEAM SECTION
A
d
tw
18.3
21.0
0.40
BENDING MOMENT AT THE COLUMN FACE

Sx
338

Ix
2660

rx
6.55

ry
4.08

Zx
390

k
2.16

Sx
127
850

Ix
rx
1330
8.53
ft-kips, SD level

ry
1.77

Zx
144

k
1.12

STRUCTURAL STEEL YIELD STRESS

Fy =

50

ksi

THE DESIGN IS ADEQUATE.

THE FACTOR GRAVITY LOAD ON THE BEAM

wu =

4.2

klf

(Continuity column stiffeners 5/8 x 7

THE FACTOR AXIAL LOAD ON THE COLUMN


BEAM LENGTH BETWEEN COL. CENTERS
AVERAGE STORY HEIGHT OF ABOVE & BELOW
=
BOLTS
1 5/8
in
GRADES (A325 or A490)
A325

Pu =
L=
h=

800
30
12

kips
ft
ft

with 7/16" fillet weld to web & CP to flanges.


A doubler plate is not required. )

PLATE & SHIM

tp =

1 5/8

NUMBER COLUMNS

Nc =

NUMBER BEAM

1
Nb =
(One Side Only)

ANALYSIS
g =Max( bbf - , tw + 3 ) =

in

2
(Top & Bot)

6.00

in

Pb = 3 =

3.75

in (AISC 358 Tab 6.1)

Pf = 1.5 =

2.00

in (AISC 358 Tab 6.1)

Sh = dc / 2 + tp + 1" + (2Pf + Pb - 1") tan-1 30o


= 22.17 in
4.62
in
c = 2 Pf + tbf =
bp = g + 3 =

<

10.88

in

bcf

[Satisfactory]

CHECK BEAM LOCAL BUCKLING LIMITATIONS (AISC 341-10 Tab. D1.1)


bf / (2tf ) =
6.70
<
0.3 (Es / Fy)0.5 = 7.22
Where

Es =

[Satisfactory]

29000 ksi

h / tw = 46.90 <
2.45 (Es / Fy)0.5 =
59.00
[Satisfactory]
CHECK COLUMN LOCAL BUCKING LIMITATIONS (AISC 341-10 Tab. D1.1)
bf / (2tf ) =
5.06
<
0.3 (Es / Fy)0.5 = 7.22
[Satisfactory]
h / tw =

<

11.61
[Satisfactory]

3.76(Es/Fy)0.5(1-2.75Pu/bPy) =

N/A

, for Pu/bPy 0.125

1.12(Es/Fy)0.5(2.33-Pu/bPy) =

55.11

, for Pu/bPy > 0.125

Where b =

0.9

, Py = FyA =

3100

kips

CHECK BEAM - COLUMN RATIO REQUIREMENT (AISC 341-10 Sec. E3.4a)


Mpc* / (Mpb* ) =
2.59
>
1.00
[Satisfactory]

Where

Mpc* = Nc Zc (Fyc - Pu / Ag ) =

2411 ft-kips

Mpb* = Nb (Mhinge + Mv) =

930 ft-kips, at center of column

Mv = Vhinge Sh = [2Mhinge /(L-2Sh)+wu(L-2Sh)/2] Sh=


Mhinge = CprRyFyb Zb =

726

Ry =

1.1

(AISC 341-10 Tab. A3.1)

Cpr =

1.1

(FEMA Sec. 3.5.5.1)

CHECK BENDING MOMENT AT THE COLUMN FACE (FEMA Sec. 3.6.2.1.2)


Mf = Mhinge + [2Mhinge / (L - 2Sh) + wu(L - 2Sh)/2] (Sh - dc /2) =
=
Where

850

ft-kips

<

d0 = db + Pf - 0.5 tbf =
di = d0 - c - Pb =
Ffu = Mf / ( db - tbf ) =
Tub =

114.9

3.4 Tub (d0 + di ) =


22.69

14.33

in

in
500.37

204

ft-kips

ft-kips

858
1205

ft-kips

= Mf , input value for non-seismic

ft-kips

[Satisfactory]

Tb =

103

Abt =

1.28

kips, (AISC 360-10, Tab. J3.1)


in2 / bolt

kips

kips, (FEMA Sec. 3.6.2.1.2)

(0.00002305 Pf0.591 Ffu2.583 / (tp0.895 dbt1.909 tbw0.327 bp0.965) + Tb =


[Satisfactory]

>

114.3

kips

(Cont'd)

CHECK SHEAR CAPACITY AT THE COLUMN FACE (FEMA Sec. 3.6.2.1.3)


in2
Ab =
1.28
>
[2 Mf / (L - dc) + Vg ] / 6Fv =
Where

Vg = wu (L - dc) / 2 =
Fv = Fnv =

60.3
36

0.55

[Satisfactory]

kips
ksi, (AISC 360-10, Tab. J3.2)

CHECK END PLATE THICKNESS (FEMA Sec. 3.6.2.1.4)


1.625 in
>
tp =
Max[ 0.00609 Pf0.9 g0.6 Ffu9 / (dbt0.9 tbw0.1 bp0.7) , 0.00413 Pf0.25 g0.15 Ffu / (dbt0.7 tbw0.15 bp0.3 )] =

CHECK CONTINUITY PLATE REQUIREMENT (FEMA Sec. 3.6.2.1 & 3.3.3.1)


tcf, reqD = {m Ffu C3 / [0.9 Fyc (3.5 pb + c)]}0.5 =
0.48 in

<

1.28347 in
[Satisfactory]

tcf, actual

0.59 in
<
tcw, actual
(The continuity plates may not be required.)
1.45
, (FEMA Sec. 3.6.2.1.5 )
Ca =
C3 = g / 2 - dbt / 4 - kc =
0.4338 in

tcw, reqD = Mf / [( db - tbf )( 6 kc + 2 tp + tbf) Fyc] =


Where

m = Ca (Af / Aw )1 / 3 C3 / dbt1 / 4 =

0.8309

, (FEMA Sec. 3.6.2.1.5 )

tst = tbf for interior connection, or (tbf /2) for exterior connection =
bst =

cPn,st = cFcr A =
Where

0.56 (E / Fyst )0.5 tst =

<

in

0.62

in,

9.93

in, (AISC 358-10 Eq 6.10-10)


[Satisfactory]

USE

0.63

in, ( 5/8 in )

413.0 kips

c =

0.9

K =

0.75

,(AISC 360 E1)

I = tst (2bst + twc) 3 / 12 =

156

in4

A = 2bsttst + 25(twc) 2 =

13

in2

0.5

rst = ( I / A )

3.49 in

Pu,st = Ryb Fyb bfb tfb =

278.7 kips

The best fillet weld size (AISC 360 Sec.J2.2b)


> wMIN =
7/16
in
< wMAX =

w=

<

cPn,st

0.25

in

0.5625

in

hst = dc - 2kc =

11.38

K hst / rst < 200

(AISC 360 E2)

in

Fe =

47926

ksi (AISC 360 E3)

Fcr =

35.99

Fyst =

36

[Satisfactory]

ksi (AISC 360 E3)


kips, plate yield stress

[Satisfactory]

[Satisfactory]
The required weld length between A36 continuity plates and column web (FEMA Fig 3-6)

Lw = 0.6tstLnstFy / [(2) Fw (0.707 w)]


Where

Lnet = dc - 2(kc + 1.5) =

= (0.625 x 8.4) x 36 / [(2) 0.75 (0.6x70)(0.707x7/16)] =

<

8.4

4.42

in

2(Lnet -0.5) [Satisfactory]

(Use complete joint penetration groove welds between continuity plates & column flanges.)
CHECK PANEL ZONE THICKNESS REQUIREMENT (AISC 341 Sec. E3.6e & FEMA Sec. 3.3.3.2)
0.80
in
tReqD = MAX (t1, t2) =
t1 = Cy Mc (h - db ) / [0.9 (0.6) Fyc Ryc dc (db - tfb) h] =
Where

Cy = Sb / (Cpr Zhing) =

0.80

Sb = 2Ib / db =

127
in4

in2

930

ft-kips

Ib = Ix =

1330

Mc = Mpb* =

t2 = (dz + wz ) / 90 = (db -2tst + dc - 2kc) / 90 =


Since twc =
not required.

0.98

in

>

0.80

in

0.35

in

tReqD ,

a doubler plate is

Technical References:
1. AISC 341-10: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, 2010.
2. AISC 358-10: "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications",
American Institute of Steel Construction, 2010.
3. AISC 360-10: "Specification for Structural Steel Buildings", American Institute of Steel Construction, 2010.
4. FEMA 350: "Recommended Seismic Design Criteria for New Steel Moment-frame Buildings.", SAC Joint Venture, 2000.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

4-Bolted Stiffened Moment Connection Based on AISC 341-10, 358-10, 360-10 & FEMA-350
DESIGN CRITERIA
THE NON-SEISMIC MOMENTION CONNECTION HAS RELEASED BEAM & COLUMN SECTION LIMITS, BEAM-COLUMN RATIO
REQUIREMENT, AND BENDING MOMENT AT THE COLUMN FACE FROM MEMBER CAPACITY TO ACTUAL BEAM END FORCE.
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION
A
31.2

=>

d
12.9

tw
0.61

W12X106

bf
tf
12.20
0.99
= > W18X50
bf
tf
7.50
0.57
Mf =

BEAM SECTION
A
d
tw
14.7
18.0
0.36
BENDING MOMENT AT THE COLUMN FACE

Sx
145
Sx
88.9
550

Ix
933

rx
5.47

ry
3.11

Zx
164

k
1.59

Ix
rx
800
7.38
ft-kips, SD level

ry
1.65

Zx
101

k
0.97

STRUCTURAL STEEL YIELD STRESS

Fy =

50

ksi

THE DESIGN IS ADEQUATE.

THE FACTOR GRAVITY LOAD ON THE BEAM

wu =

4.2

klf

(Continuity column stiffeners 5/8 x 6

THE FACTOR AXIAL LOAD ON THE COLUMN


BEAM LENGTH BETWEEN COL. CENTERS
AVERAGE STORY HEIGHT OF ABOVE & BELOW
=
BOLTS
1 3/4
in
GRADES (A325 or A490)
A325

Pu =
L=
h=

800
30
12

kips
ft
ft

with 5/16" fillet weld to web & CP to flanges.


A doubler plate is required with thickness of 3/16 in. )

PLATE & SHIM

tp =

3/4

NUMBER COLUMNS

Nc =

2
(Top & Bot)

NUMBER BEAM

1
Nb =
(One Side Only)

ANALYSIS
g =Max( bbf - , tw + 3 ) =
Pf = 1.5 =

2.00

5.86

in

in

in (AISC 358 Tab 6.1)

Sh = dc / 2 + tp + 1" + (2Pf - 1") tan-1 30o


= 13.40 in
c = 2 Pf + tbf =
4.57
in
bp = g + 3 =

<

11.11

in

bcf

[Satisfactory]

CHECK BEAM LOCAL BUCKLING LIMITATIONS (AISC 341-10 Tab. D1.1)


bf / (2tf ) =
6.58
<
0.3 (Es / Fy)0.5 = 7.22
Where

Es =

[Satisfactory]

29000 ksi

h / tw = 45.23 <
2.45 (Es / Fy)0.5 =
59.00
[Satisfactory]
CHECK COLUMN LOCAL BUCKING LIMITATIONS (AISC 341-10 Tab. D1.1)
bf / (2tf ) =
6.16
<
0.3 (Es / Fy)0.5 = 7.22
[Satisfactory]
h / tw =

<

15.93
[Satisfactory]

3.76(Es/Fy)0.5(1-2.75Pu/bPy) =

N/A

, for Pu/bPy 0.125

1.12(Es/Fy)0.5(2.33-Pu/bPy) =

47.48

, for Pu/bPy > 0.125

Where b =

0.9

, Py = FyA =

1560

kips

CHECK BEAM - COLUMN RATIO REQUIREMENT (AISC 341-10 Sec. E3.4a)


Mpc* / (Mpb* ) =
1.08
>
1.00
[Satisfactory]

Where

Mpc* = Nc Zc (Fyc - Pu / Ag ) =

666 ft-kips

Mpb* = Nb (Mhinge + Mv) =

615 ft-kips, at center of column

Mv = Vhinge Sh = [2Mhinge /(L-2Sh)+wu(L-2Sh)/2] Sh=


Mhinge = CprRyFyb Zb =

509

Ry =

1.1

(AISC 341-10 Tab. A3.1)

Cpr =

1.1

(FEMA Sec. 3.5.5.1)

CHECK BENDING MOMENT AT THE COLUMN FACE (FEMA Sec. 3.6.1.1.2)


Mf = Mhinge + [2Mhinge / (L - 2Sh) + wu(L - 2Sh)/2] (Sh - dc /2) =
=
Where

550

ft-kips

<

d0 = db + Pf - 0.5 tbf =
di = d0 - c =
Ffu = Mf / ( db - tbf ) =
Tub =

123.7

2 Tub (d0 + di ) =
19.72

15.15

in

in
378.66

106

ft-kips

ft-kips

564
719

ft-kips

= Mf , input value for non-seismic

ft-kips

[Satisfactory]

Tb =

103

Abt =

1.37

kips, (AISC 360-10, Tab. J3.1)


in2 / bolt

kips

kips, (FEMA Sec. 3.6.1.1 & 3.6.2.1.2)

>
(0.00002305 Pf
[Satisfactory]

0.591

Ffu2.583 / (tp0.895 dbt1.909 tbw0.327 bp0.965) + Tb =

112.7

kips

(Cont'd)

CHECK SHEAR CAPACITY AT THE COLUMN FACE (FEMA Sec. 3.6.1.1.3)


in2
Ab =
1.37
>
[2 Mf / (L - dc) + Vg ] / 3Fv =
Where

Vg = wu (L - dc) / 2 =
Fv = Fnv =

60.7
36

0.91

ksi, (AISC 360-10, Tab. J3.2)

CHECK END PLATE THICKNESS (AISC 358-10 Eq 6.10-13)


in
0.75
>
[1.11 Mf / d Fyp Yp)]0.5 =
tp =
Where

Yp =

1258

Fyp =

36

[Satisfactory]

kips

0.40

in

[Satisfactory]

in, (AISC 358-10 Tab. 6.3 Case 1)


ksi

d =

1.0

CHECK CONTINUITY PLATE REQUIREMENT (AISC 358-10 Eq 6.10-13, FEMA Sec 3.3.3.1)
0.5
tcf, reqD = [1.11 Mf / d Fyc Yc)] =
0.30 in
<
tcf, actual
Where

Yc =

1595

in, (AISC 358-10 Tab. 6.5 Stiffened)

in
>
tcw, actual
(The continuity plates required.)
for interior connection, or (tbf /2) for exterior connection =
0.57
in,

tcw, reqD = Mf / [( db - tbf )( 6 kc + 2 tp + tbf) Fyc] =


tst = tbf
bst =

cPn,st = cFcr A =
Where

0.5

<

in

0.65

0.56 (E / Fyst )

tst =

9.93

USE

0.63

in, ( 5/8 in )

in, (AISC 358-10 Eq 6.10-10)


[Satisfactory]

345.0 kips

c =

0.9

K =

0.75

,(AISC 360 E1)

I = tst (2bst + twc) 3 / 12 =

98

in4

A = 2bsttst + 25(twc) 2 =

11

in2

0.5

rst = ( I / A )

3.04 in

Pu,st = Ryb Fyb bfb tfb =

235.1 kips

The best fillet weld size (AISC 360 Sec.J2.2b)


> wMIN =
5/16
in
< wMAX =

w=

<

cPn,st

0.1875

in

0.4375

in

hst = dc - 2kc =

9.72

K hst / rst < 200

(AISC 360 E2)

in

Fe =

49670

ksi (AISC 360 E3)

Fcr =

35.99

Fyst =

36

[Satisfactory]

ksi (AISC 360 E3)


kips, plate yield stress

[Satisfactory]

[Satisfactory]
The required weld length between A36 continuity plates and column web (FEMA Fig 3-6)
Lw = 0.6tstLnstFy / [(2) Fw (0.707 w)]

Where

Lnet = dc - 2(kc + 1.5) =

= (0.625 x 6.7) x 36 / [(2) 0.75 (0.6x70)(0.707x5/16)] =

<

6.7

4.61

in

2(Lnet -0.5) [Satisfactory]

(Use complete joint penetration groove welds between continuity plates & column flanges.)
CHECK PANEL ZONE THICKNESS REQUIREMENT (AISC 341 Sec. E3.6e & FEMA Sec. 3.3.3.2)
0.77
in
tReqD = MAX (t1, t2) =
t1 = Cy Mc (h - db ) / [0.9 (0.6) Fyc Ryc dc (db - tfb) h] =
Where

Cy = Sb / (Cpr Zhing) =

0.80

Sb = 2Ib / db =

89
in4

in2

615

ft-kips

Ib = Ix =

800

Mc = Mpb* =

t2 = (dz + wz ) / 90 = (db -2tst + dc - 2kc) / 90 =


Since twc =
0.61
required with thickness of 3/16 in.

in

<

0.77

in

0.29

in

tReqD ,

a doubler plate is

Technical References:
1. AISC 341-10: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, 2010.
2. AISC 358-10: "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications",
American Institute of Steel Construction, 2010.
3. AISC 360-10: "Specification for Structural Steel Buildings", American Institute of Steel Construction, 2010.
4. FEMA 350: "Recommended Seismic Design Criteria for New Steel Moment-frame Buildings.", SAC Joint Venture, 2000.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

4-Bolted Unstiffened Moment Connection Based on AISC 341-10, 358-10, 360-10 & FEMA-350
DESIGN CRITERIA
THE NON-SEISMIC MOMENTION CONNECTION HAS RELEASED BEAM & COLUMN SECTION LIMITS, BEAM-COLUMN RATIO
REQUIREMENT, AND BENDING MOMENT AT THE COLUMN FACE FROM MEMBER CAPACITY TO ACTUAL BEAM END FORCE.
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION
A
d
tw
28.2
12.7
0.55
BEAM SECTION
A
d
tw
10.3
17.7
0.30
BENDING MOMENT AT THE COLUMN FACE

= > W12X96
bf
tf
12.20
0.90
= > W18X35
bf
tf
6.00
0.43
Mf =

Sx
131
Sx
57.6
380

Ix
833

rx
5.43

ry
3.09

Zx
147

k
1.50

Ix
rx
510
7.04
ft-kips, SD level

ry
1.22

Zx
67

k
0.83

STRUCTURAL STEEL YIELD STRESS

Fy =

50

ksi

THE DESIGN IS ADEQUATE.

THE FACTOR GRAVITY LOAD ON THE BEAM

wu =

4.2

klf

(Continuity column stiffeners 7/16 x 6

THE FACTOR AXIAL LOAD ON THE COLUMN


BEAM LENGTH BETWEEN COL. CENTERS
AVERAGE STORY HEIGHT OF ABOVE & BELOW
=
BOLTS
1 1/16 in
GRADES (A325 or A490)
A325
PLATE & SHIM
tp =
3/4
in

Pu =
L=
h=

800
30
12

kips
ft
ft

with 1/4" fillet weld to web & CP to flanges.


A doubler plate is not required. )

NUMBER COLUMNS

Nc =

NUMBER BEAM

Nb =
1
(One Side Only)

ANALYSIS
g =Max( bbf - , tw + 3 ) =
Pf = 1.5 =

1.75

2
(Top & Bot)

5.00

in

in (AISC 358 Tab 6.1)

Sh = dc / 2 + tp + db / 3
=
c = 2 Pf + tbf =
bp = g + 3 =

<

13.00
3.93

in
in

9.00

in

bcf

[Satisfactory]

CHECK BEAM LOCAL BUCKLING LIMITATIONS (AISC 341-10 Tab. D1.1)


bf / (2tf ) =
7.06
<
0.3 (Es / Fy)0.5 = 7.22
Where

Es =

[Satisfactory]

29000 ksi

h / tw = 53.49 <
2.45 (Es / Fy)0.5 =
59.00
[Satisfactory]
CHECK COLUMN LOCAL BUCKING LIMITATIONS (AISC 341-10 Tab. D1.1)
bf / (2tf ) =
6.78
<
0.3 (Es / Fy)0.5 = 7.22
[Satisfactory]
h / tw =

<

17.64
[Satisfactory]

3.76(Es/Fy)0.5(1-2.75Pu/bPy) =

N/A

, for Pu/bPy 0.125

1.12(Es/Fy)0.5(2.33-Pu/bPy) =

45.84

, for Pu/bPy > 0.125

Where b =

0.9

, Py = FyA =

1410

kips

CHECK BEAM - COLUMN RATIO REQUIREMENT (AISC 341-10 Sec. E3.4a)


Mpc* / (Mpb* ) =
1.25
>
1.00
[Satisfactory]

Where

Mpc* = Nc Zc (Fyc - Pu / Ag ) =

530 ft-kips

Mpb* = Nb (Mhinge + Mv) =

425 ft-kips, at center of column

Mv = Vhinge Sh = [2Mhinge /(L-2Sh)+wu(L-2Sh)/2] Sh=


Mhinge = CprRyFyb Zb =

335

Ry =

1.1

(AISC 341-10 Tab. A3.1)

Cpr =

1.1

(FEMA Sec. 3.5.5.1)

CHECK BENDING MOMENT AT THE COLUMN FACE (FEMA Sec. 3.6.1.1.2)


Mf = Mhinge + [2Mhinge / (L - 2Sh) + wu(L - 2Sh)/2] (Sh - dc /2) =
=
Where

380

ft-kips

<

d0 = db + Pf - 0.5 tbf =
di = d0 - c =
Ffu = Mf / ( db - tbf ) =
Tub =

75.1

2 Tub (d0 + di ) =
19.24

15.31

in

in
263.97

89

ft-kips

ft-kips

381
432

ft-kips

= Mf , input value for non-seismic

ft-kips

[Satisfactory]

Tb =

51

Abt =

0.83

kips, (AISC 360-10, Tab. J3.1)


in2 / bolt

kips

kips, (FEMA Sec. 3.6.1.1 & 3.6.2.1.2)

>
(0.00002305 Pf
[Satisfactory]

0.591

Ffu2.583 / (tp0.895 dbt1.909 tbw0.327 bp0.965) + Tb =

62.8

kips

(Cont'd)

CHECK SHEAR CAPACITY AT THE COLUMN FACE (FEMA Sec. 3.6.1.1.3)


in2
0.83
>
[2 Mf / (L - dc) + Vg ] / 3Fv =
Ab =
Where

Vg = wu (L - dc) / 2 =
Fv = Fnv =

60.8
36

0.81

ksi, (AISC 360-10, Tab. J3.2)

CHECK END PLATE THICKNESS (AISC 358-10 Eq 6.10-13)


0.5
in
0.75
>
[1.11 Mf / d Fyp Yp)] =
tp =
Where

[Satisfactory]

kips

Yp =

864

in, (AISC 358-10 Tab. 6.2)

Fyp =

36

ksi

d =

0.40

in

[Satisfactory]

1.0

CHECK CONTINUITY PLATE REQUIREMENT (AISC 358-10 Eq 6.10-13, FEMA Sec 3.3.3.1)
0.5
0.41 in
<
tcf, actual
tcf, reqD = [1.11 Mf / d Fyc Yc)] =
Where

Yc =

594

in, (AISC 358-10 Tab. 6.5 Unsiffened)

0.48 in
<
tcw, actual
(The continuity plates may not be required.)
for interior connection, or (tbf /2) for exterior connection =
0.43
in,
USE

tcw, reqD = Mf / [( db - tbf )( 6 kc + 2 tp + tbf) Fyc] =


tst = tbf
bst =

cPn,st = cFcr A =
Where

0.5

<

in

0.56 (E / Fyst )

tst =

6.95

0.44

in, ( 7/16 in )

in, (AISC 358-10 Eq 6.10-10)


[Satisfactory]

242.9 kips

c =

0.9

K =

0.75

,(AISC 360 E1)

I = tst (2bst + twc) 3 / 12 =

68

in4

A = 2bsttst + 25(twc) 2 =

in2

0.5

rst = ( I / A )

3.01 in

Pu,st = Ryb Fyb bfb tfb =

140.3 kips

The best fillet weld size (AISC 360 Sec.J2.2b)


> wMIN =
w=
1/4
in
< wMAX =

<

cPn,st

0.1875

in

0.3125

in

hst = dc - 2kc =

9.7

K hst / rst < 200

(AISC 360 E2)

in

Fe =

48920

ksi (AISC 360 E3)

Fcr =

35.99

Fyst =

36

[Satisfactory]

ksi (AISC 360 E3)


kips, plate yield stress

[Satisfactory]

[Satisfactory]
The required weld length between A36 continuity plates and column web (FEMA Fig 3-6)
Lw = 0.6tstLnstFy / [(2) Fw (0.707 w)]

Where

Lnet = dc - 2(kc + 1.5) =

= (0.4375 x 6.7) x 36 / [(2) 0.75 (0.6x70)(0.707x1/4)] =

<

6.7

4.02

in

2(Lnet -0.5) [Satisfactory]

(Use complete joint penetration groove welds between continuity plates & column flanges.)
CHECK PANEL ZONE THICKNESS REQUIREMENT (AISC 341 Sec. E3.6e & FEMA Sec. 3.3.3.2)
0.54
in
tReqD = MAX (t1, t2) =
t1 = Cy Mc (h - db ) / [0.9 (0.6) Fyc Ryc dc (db - tfb) h] =
Where

Cy = Sb / (Cpr Zhing) =

0.79

Sb = 2Ib / db =

58
in4

in2

425

ft-kips

Ib = Ix =

510

Mc = Mpb* =

t2 = (dz + wz ) / 90 = (db -2tst + dc - 2kc) / 90 =


Since twc =
not required.

0.55

in

>

0.54

in

0.29

in

tReqD ,

a doubler plate is

Technical References:
1. AISC 341-10: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, 2010.
2. AISC 358-10: "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications",
American Institute of Steel Construction, 2010.
3. AISC 360-10: "Specification for Structural Steel Buildings", American Institute of Steel Construction, 2010.
4. FEMA 350: "Recommended Seismic Design Criteria for New Steel Moment-frame Buildings.", SAC Joint Venture, 2000.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Steel Stair Design Based on AISC 360-05

INPUT DATA & DESIGN SUMMARY


COLUMN SECTION (Tube or Pipe)
Tube

=>
rmin

3.37

1.52

0.23

4.00

=>

W16X26

FLOOR BEAM - 1
A
7.68

Ix

Sx

Zx

15.70

301.00

38.40

44.20

=>

MC8X8.5

STRINGER - 1 (Channel or Tube)


Channel

A
2.50

Ix

Sx

Zx

8.00

23.30

5.82

6.95

STRINGER - 2 (Channel or Tube)


Channel

A
6.08

=>

A
5.51

Ix

Sx

Zx

12.00

129.00

21.50

25.60

=>

A
5.51

DIMENSIONS

H =
L1 =

Ix

Sx

Zx

8.00

43.90

11.00

13.90

=>

C8X18.75

Ix

Sx

Zx

8.00

43.90

11.00

13.90

16
12

ft, story Ht
ft

L2 =

ft

L3 =

10

ft

NUMBER OF STORIES
GRAVITY LOAD

C8X18.75

LANDING BEAM - 2 (Channel or Tube)


Channel

C12X20.7

LANDING BEAM - 1 (Channel or Tube)


Channel

HSS4X4X1/4

n =
DL =
LL =

50
100

2
psf
psf

THE STAIR DESIGN IS ADEQUATE.

ANALYSIS
STRINGER - 1

=
33.69 deg, from horizontal
w = 0.25 (DL / Cos + LL) L3 =
400
R = 0.5 w L1 =

2.40

kips

M = w L12 / 8 =

7.20

ft-kips

Fy =

ksi

36.00

Mn / b = Fy Zx / 1.67 =

12.49

ft-kips

>

M
E =
29000
ksi
LL = 5 (wLL Cos ) (L1 / Cos )4 / (384 E I) =

<

(L1 / Cos ) / 240 =

0.72

plf , projected

in

[Satisfactory]
0.46

in
[Satisfactory]

LANDING BEAM - 1
w = 0.5 (DL + LL) L2 =
450
plf
P =
2.40
kips, from STRINGER - 1
R = 0.5 w L3 + P =
4.65
kips

__
2
M = w L3 / 8 + P L3 / 2 =

Fy =

36.00

17.63

ft-kips

24.97

ft-kips

ksi

Mn / b = Fy Zx / 1.67 =

>

M
4
3
LL = 5 wLL L3 / (384 E I) + PLL L3 / (24 E I) =

<

L3 / 240 =

Page 394 of 533


524

0.50

in

[Satisfactory]
0.14

in

[Satisfactory]

(cont'd)
STRINGER - 2

w =
400
plf , projected, from STRINGER - 1
P =
4.65
kips, from LANDING BEAM - 1
RL = [w L1 (0.5 L1 + L2) + P L2] / (L1 + L2) =
4.75

kips

RR = [w L1 (0.5 L1) + P L1] / (L1 + L2) =

kips

X = RL / w =

11.87

Mmax = RL X - (0.5 w X2 ) =
Fy =

36.00

4.70

ft, from left


28.21

ft-kips

45.99

ft-kips

ksi

Mn / b = Fy Zx / 1.67 =

>

M
[Satisfactory]
4
3
LL = 5 wLL (L1 + L2) / (384 E I) + PLL (L1 +L2) / (48 E I) =

<

(L1 + L2) / 240 =

0.90

in

0.24

[Satisfactory]

LANDING BEAM - 2
w =
450
R = 0.5 w L3 =

plf, from LANDING BEAM - 1


2.25
kips

M = w L32 / 8 =

5.63

Fy =

ksi

36.00

Mn / b = Fy Zx / 1.67 =

ft-kips
24.97

>
4
LL = 5 wLL L3 / (384 E I) =

<

L3 / 240 =

0.50

ft-kips
M

[Satisfactory]

0.05

in

in

[Satisfactory]

FLOOR BEAM - 1
L
w
P
R

=
12
ft
=
600
plf, floor gravity load
= P1 + P2 =
4.80 kips, total point loads, from STRINGER - 1
= 0.5 w L + 0.5 P =
6.00
kips

M = w L2 / 8 + P L3 / 4 =
Fy =

50.00

25.21

ft-kips

ksi

Mn / b = Fy Zx / 1.67 =

110.28 ft-kips

>
M
4
3
LL = 5 wLL L / (384 E I) + PLL L / (48 E I) =
<

L / 240 =

0.60

[Satisfactory]
0.04

in

in

[Satisfactory]

COLUMN
P =
6.95
R =nP=
KL = H =
K =
1.0

kips
13.90
16

Fy =
K /r=

ksi

46
126

Fe =

18

ksi

Fcr =

16

ksi

Pn / c = Fcr Ag / 1.67 =

kips
ft

31.80 kips

>
Mc = Mn / b =
F =

17.98

0.18 W =
0.18
x(
50
(If no landing seismic load, F shall be zero.)

Mr = F H / 4 =

1.62

Pr + 8 M r
Pc 9 M c

, for P r 0.2
Pc

Pr + M r
2Pc
Mc

, for P r < 0.2


Pc

<

H / 240 =

[Satisfactory]

10.77 ft-kips, (AISC 360-05 F)

psf x

45.0

ft2 ) =

0.41

ft-kips

__

3
F = F H / (48 E I) =

/ 1.67 =

0.26

0.80

Page 395 of 533


524

0.40

<

1.0

[Satisfactory]

in

in

[Satisfactory]

kips, ASD

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Steel Stair Design Based on AISC Manual 9th

INPUT DATA & DESIGN SUMMARY


COLUMN SECTION (Tube or Pipe)
Tube

=>
rmin

3.37

1.52

0.23

4.00

=>

W16X26

FLOOR BEAM - 1
A
7.68

Ix

Sx

15.70

301.00

38.40

=>

MC8X8.5

STRINGER - 1 (Channel or Tube)


Channel

A
2.50

Ix

Sx

8.00

23.30

5.82

STRINGER - 2 (Channel or Tube)


Channel

A
6.08

=>

A
5.51

Ix

Sx

12.00

129.00

21.50

=>

A
5.51

DIMENSIONS

H =
L1 =

Ix

Sx

8.00

43.90

11.00

=>

C8X18.75

Ix

Sx

8.00

43.90

11.00

16
12

ft, story Ht
ft

L2 =

ft

L3 =

10

ft

NUMBER OF STORIES
GRAVITY LOAD

C8X18.75

LANDING BEAM - 2 (Channel or Tube)


Channel

C12X20.7

LANDING BEAM - 1 (Channel or Tube)


Channel

HSS4X4X1/4

n =
DL =
LL =

50
100

2
psf
psf

THE STAIR DESIGN IS ADEQUATE.

ANALYSIS
STRINGER - 1

=
33.69 deg, from horizontal
w = 0.25 (DL / Cos + LL) L3 =
400
R = 0.5 w L1 =

2.40

M = w L12 / 8 =

7.20

ft-kips

f b = M / Sx =

14.85

ksi

Fb = 0.6 Fy =
21.60
ksi
>
E =
29000
ksi
LL = 5 (wLL Cos ) (L1 / Cos )4 / (384 E I) =

<

(L1 / Cos ) / 240 =

plf , projected

kips

0.72

fb

[Satisfactory]
0.46

in

in
[Satisfactory]

LANDING BEAM - 1
w = 0.5 (DL + LL) L2 =
450
plf
P =
2.40
kips, from STRINGER - 1
R = 0.5 w L3 + P =
4.65
kips

__
M = w L32 / 8 + P L3 / 2 =

17.63

f b = M / Sx =

19.23

ksi

Fb = 0.6 Fy =

21.60

ksi

ft-kips

>

LL = 5 wLL L34 / (384 E I) + PLL L33 / (24 E I) =

<

L3 / 240 =

Page 396 of 533


524

0.50

in

fb

[Satisfactory]
0.14

in

[Satisfactory]

(cont'd)
STRINGER - 2

w =
400
plf , projected, from STRINGER - 1
P =
4.65
kips, from LANDING BEAM - 1
RL = [w L1 (0.5 L1 + L2) + P L2] / (L1 + L2) =
4.75

kips

RR = [w L1 (0.5 L1) + P L1] / (L1 + L2) =

4.70

kips

fb

[Satisfactory]

X = RL / w =

11.87
2

ft, from left

Mmax = RL X - (0.5 w X ) =

28.21

fb = Mmax / Sx =

15.75

ksi

Fb = 0.6 Fy =

21.60

ksi

ft-kips

>

LL = 5 wLL (L1 + L2)4 / (384 E I) + PLL (L1 +L2)3 / (48 E I) =

<

(L1 + L2) / 240 =

0.90

in

0.24
[Satisfactory]

LANDING BEAM - 2
w =
450
R = 0.5 w L3 =
2

plf, from LANDING BEAM - 1


2.25
kips

M = w L3 / 8 =

5.63

ft-kips

f b = M / Sx =

6.14

ksi

Fb = 0.6 Fy =

21.60

ksi

LL = 5 wLL L3 / (384 E I) =
4

<

L3 / 240 =

0.50

>

fb

0.05

in

in

[Satisfactory]
[Satisfactory]

FLOOR BEAM - 1
L
w
P
R

=
12
ft
=
600
plf, floor gravity load
= P1 + P2 =
4.80 kips, total point loads, from STRINGER - 1
= 0.5 w L + 0.5 P =
6.00
kips

M = w L2 / 8 + P L3 / 4 =

25.21

f b = M / Sx =

7.88

ksi

33.00

ksi

Fb = 0.66 Fy =

ft-kips

>

fb

LL = 5 wLL L / (384 E I) + PLL L / (48 E I) =


4

<

L / 240 =

0.60

[Satisfactory]
0.04

in

in

[Satisfactory]

COLUMN
P =
6.95
R =nP=
KL = H =
K =
1.0

kips
13.90
16

Fy =

ksi

46

Cc = (22Es/Fy)0.5 =
K /r=
126
F = (K / r) / Cc =

112
1.13

Fa =

kips
ft

(1-F /2)Fy / (5/3+3F/8-F /8) =


2

12 Es/[23(K /r) ] =

Rallow = A Fa =

31.60

__
Page 397 of 533
524

kips

>

N/A

kis, for Cc > (K /r)

9.38

kis, for Cc < (K /r)


R

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Web Tapered Frame Design Based on AISC-ASD 9th, Appendix F


INPUT DATA & DESIGN SUMMARY
STEEL YIELD STRESS

Fy =

LEFT COLUMN DIMENSIONS

36

ksi

bf =

in

t f = 0.1875 in
t w = 0.1345 in

RIGHT COLUMN DIMENSIONS

d1 =

12

in

d2 =

17

in

H1 =

12

ft

bf =

in

tf =

0.25

in

bf =

in

tf =

0.25

in

tw =

0.25

in

d3 =

12

in

d4 =

34

in

H2 =

14

ft

LEFT BEAM DIMENSIONS

t w = 0.3125 in
d5 =

RIGHT BEAM DIMENSIONS

in

d6 =

13

in

L1 =

15

ft

RIDGE HEIGHT

H =

18

GRAVITY LOAD

w1 =

0.24

kips / ft ( " - " for wind uplift)

w2 =

0.5

kips / ft ( " - " for wind uplift)

F =

3.6

kips ( " - " to left direction)

0.5

kips / ft ( " - " to left direction)

bf =

in

tf =

0.25

in

p =

t w = 0.3125 in

BEAM STIFFENER SPACING

a bm =

10

ft

COLUMN STIFFENER SPACING

a col =

ft

UNBRACED LENGTH / PURLIN SPACING L b,top =

ft

d5 =

in

d7 =

38

in

L2 =

26

ft

LATERAL LOAD

UNBRACED LENGTH AT BOTTOM FLANGE L b,bot =


10
ft
(Diaphragm is not bracing member. L is different with "
" in F1.3, pg 5-47)

THE FRAME DESIGN IS ADEQUATE.


ANALYSIS
DETERMINE REACTIONS
R1 =

0.4

kips

R2 =

7.6

kips

R3 =

3.6

kips

R4 =

9.0

kips

R5 =

3.6

kips

R6 =

4.0

kips

DETERMINE ALLOWABLE FLEXURAL STRESS (APP. F7.4, pg 5-103)

Fy
2
1.0
F y 0.60 F y , for F b > F y / 3
3
6 B F 2s + F 2w
F b =
B F 2s +F 2w , for F b F y / 3
where

I To = (tf bf3 + d0 tw3 / 6) / 12

A To = tf bf + d0 tw / 6

r To
hs

__

= MIN[(dL - d0) / d0 , 0.268 L/d0, 6.0]

A f = tf bf

I To
ATo

= 1.0 + 0.0230

F s

Ld 0
Af

ft

F w

Page 398 of 533


524

12000

h sL d o / A f

170000

( h wL / r To )2

(cont'd)

h w = 1.0 + 0.00385

Left Col
Right Col
L. Bm (+)
(-)
R. Bm (+)
(-)

Length
11.5
12.5
15.6
15.6
25.1
25.1

r To

A To
1.21
1.75
1.72
1.72
1.72
1.72

0.42
1.83
0.44
0.44
1.79
3.22

I To
2
3
3
3
3
3

r To
1.27
1.22
1.23
1.23
1.23
1.23

1.75
1.0 + 0.25

Hs
1.40
2.60
1.21
1.30
1.85
3.18

Hw
1.02
1.08
1.01
1.02
1.05
1.12

F s
4.85
3.21
22.91
10.68
14.98
4.37

F w
14.03
9.68
69.97
17.32
65.24
14.22

B
1.51
1.31
1.50
1.50
1.31
1.21

F b
17.56
13.20
21.60
19.28
21.60
15.99

DETERMINE ALLOWABLE SHEAR STRESS (F4, pg 5-49)

0.4 F y , for h / t w380 F y

Fv =

where

CvF y
0.4 F y , for h / t w>380 F y
2.89

Left Col
Right Col
Left Bm
Right Bm

a
10.0
10.0
5.0
5.0

h
16.63
33.50
12.50
37.50

h = dL - 2 tf
4.0+
=

kv

h / tw
124
134
40
120

380 / F y
63
63
63
63

5.34

5.34+

0.5

45000 k v

, for a / h1.0

( a / h )2
4.0

, for a / h >1.0

( a / h )2

Kv
5.42
5.65
5.51
6.90

Cv
0.44
0.39
1.86
0.60

Cv

F y( h / t w )
190
h /tw

, for C v 0.8

k v , for
C v >0.8
Fy

F b
5.52
4.90
14.40
7.46

DETERMINE ALLOWABLE COMPRESSIVE STRESS (APP. F7.3, pg 5-102)

F a

2
1.0 S 2 F y
2C c
, for S C c
3
5 3S
+
S 3
3 8C c 8C c
12 2E
, for S >C c
23S 2

Left Col
Right Col
Left Bm
Right Bm

l
11.5
12.5
15.6
25.1

(effective length factor by an analysis)


where K =
S = K l / r ox

Cc

E=

K
2.0
2.0
2.5
2.5

Cc
126
126
126
126

Ix
53
81
44
44

A
3.49
5.50
5.31
5.31

tw

Af

2 2E
Fy

29000

ksi

r ox
3.90
3.84
2.89
2.89

S
70.61
78.16
161.71
261.07

F a
16.37
15.56
5.71
2.19

CHECK EACH SECTION CAPACITIES


d0

dL

tf

bf

12
12
9
9

17
34
13
38

0.1875
0.25
0.25
0.25

5
5
5
5

Section
d (in)
I (in4)

1
12
87

2
14
116

3
15
151

4
17
191

5
12
126

6
10
95

7
9
70

8
19
387

9
28
1094

10
38
2331

11
27
840

12
19
384

13
12
126

Aw (in2)
N (kips)
V (kips)
M (ft-k)
f a (ksi)

1.61
7.6
0.36
0.0

1.84
7.6
-1.64
-2.0

2.06
7.6
-3.64
-10.6

2.29
7.6
-5.10
-25.8

3.65
3.6
6.18
-31.7

3.23
3.6
5.09
-13.4

2.81
3.6
4.00
0.0

5.83
3.6
0.14
20.8

8.85
3.6
-3.72
11.8

11.88
3.6
-7.58
-27.0

6.67
9.0
3.60
33.6

4.83
9.0
3.60
16.8

3.00
9.0
3.60
0.0

2.18

2.05

1.93

F a (ksi)

16.37

16.37

16.37

Left Col
Right Col
Left Bm
Right Bm

f v (ksi)

0.22

0.89

1.76

F v (ksi)

5.52

5.52

5.52

f b (ksi)

0.00

1.41

6.48

F b (ksi)

17.56

17.56

17.56

f a < F a [Satisfactory]

0.1345 0.9375
0.25
1.25
0.3125
1.25
0.3125
1.25

1.83

0.59

0.63

0.68

0.43

0.32

0.25

0.98

1.23

1.64

16.37

5.71

5.71

5.71

2.19

2.19

2.19

15.56

15.56

15.56

__
2.23

1.69

1.58

1.42

0.02

0.42

0.64

0.54

0.75

1.20

5.52

14.40

14.40

14.40

7.46

7.46

7.46

4.90

4.90

4.90

13.83

17.55

8.69

0.00

6.02

1.84

2.64

6.41

5.08

0.00

17.56

19.28

19.28

21.60

21.60

21.60

15.99

13.20

13.20

13.20

f v < F v [Satisfactory]

Page 399 of 533


524

f b < F b [Satisfactory]

(cont'd)
CHECK COMBINED FLEXURE AND AXIAL FORCE (APP. F7.4, pg 5-104)

f a0
F a

(fa

f bl
F b

f a0

, f b) =

f a0

, for

F a

F a
+

L arg er of

0.15
C m ' f bl

f a0
F e'

F b

, for

f a0
f
+ bl
0.6 F y F b

Left Col
Right Col
Left Bm
Right Bm

f a0
2.18
1.64
0.68
0.68

f bl
13.83
6.41
17.55
6.41

F a
16.37
15.56
5.71
2.19

F b
17.56
13.20
19.28
15.99

f a0
F a

F e'
29.95
24.45
5.71
2.19

> 0.15

Cm'
0.94
0.94
0.90
0.78

( fa , fb )
0.92
0.59
1.03
0.76

Technical Reference:
1. AISC: "Manual of Steel construction 9th", American Institute of Steel Construction, 1990.

__
Page 400 of 533
524

1.3

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Web Tapered Portal Design Based on AISC-ASD 9th Appendix F and/or AISC Design Guide 25
INPUT DATA & DESIGN SUMMARY
STEEL YIELD STRESS

Fy =

LEFT COLUMN DIMENSIONS

50

ksi

bf =

in

t f = 0.1875 in

RIGHT COLUMN DIMENSIONS

tw =

0.25

in

d1 =

12

in

d2 =

17

in

H1 =

12

ft

in

bf =

in

tf =

0.25

in

tw =

0.25

in

d3 =

22

in

d4 =

34

in

H2 =

14

ft

LEFT BEAM DIMENSIONS

bf =
tf =

RIGHT BEAM DIMENSIONS

bf =
tf =

BASE (d1 & d3) PINNED ?

0.375 in

tw =

0.25

in

d5 =

48

in

RIDGE HEIGHT

H =

18

d6 =

13

in

GRAVITY LOAD

w1 =

0.24

kips / ft ( " - " for wind uplift)

L1 =

30

ft

w2 =

0.5

kips / ft ( " - " for wind uplift)

F =

18

kips ( " - " to left direction)

p =

0.5

kips / ft ( " - " to left direction)

in

LATERAL LOAD

0.375 in

ft

tw =

0.25

in

BEAM STIFFENER SPACING

a bm =

10

ft

d5 =

48

in

COLUMN STIFFENER SPACING

a col =

ft

d7 =

22

in

UNBRACED LENGTH / PURLIN SPACING L b,top =

ft

L2 =

41

ft

No

UNBRACED LENGTH AT BOTTOM FLANGE L b,bot =


10
ft
(Diaphragm is not bracing member. L is different with " l " in F1.3, pg 5-47)

, (fixed)

THE FRAME DESIGN IS ADEQUATE.


HORIZONTAL DRIFT

'H =

BEAM DEFLECTION

'max / L =

0.10 in, (horiz. to right)


1 / 487

ANALYSIS
DETERMINE REACTIONS
RX =

-3.6

kips (Left)

RX =

24.6

kips (Right)

RY =

9.5

kips (Left)

RY =

18.2

kips (Right)

RM =

-18.6

ft-kips (Left)

R M = -108.6 ft-kips (Right)

DETERMINE ALLOWABLE FLEXURAL STRESS (APP. F7.4, pg 5-103)

F bJ
where

Fy
2 1.0
F y d0.60 F y , for F bJ ! F y / 3
3
2
2
6 B F sJ  F wJ

B F 2sJ F 2wJ , for F bJ dF y / 3

A f = tf bf

J = MIN[(dL - d0) / d0 , 0.268 L/d0, 6.0]

A To = tf bf + d0 tw / 6

I To = (tf bf3 + d0 tw3 / 6) / 12

r To
hs

hw

I To
ATo
1.0  0.0230J

1.0  0.00385J

F sJ
Ld 0
Af

r To

F wJ
B

12000
h sL d o / A f
170000

h wL / r To 2
1.75
1.0  0.25

(cont'd)

Left Col
Right Col
L. Bm (+)
(-)
R. Bm (+)
(-)

Length
11.5
13.2
29.6
29.6
39.7
39.7

J
0.42
0.55
1.24
2.47
0.73
1.18

A To
2.00
2.92
3.54
3.54
3.92
3.92

I To
8
11
16
16
16
16

r To
2.00
1.91
2.13
2.13
2.02
2.02

Hs
1.32
1.52
1.46
2.30
1.35
1.81

Hw
1.01
1.02
1.03
1.07
1.02
1.04

F sJ
8.26
4.54
31.64
10.04
20.16
7.55

F wJ
34.91
24.02
202.97
46.46
187.18
45.03

B
1.51
1.48
1.37
1.26
1.44
1.38

F bJJ
28.19
25.64
30.00
28.68
30.00
28.91

DETERMINE ALLOWABLE SHEAR STRESS (F4, pg 5-49)

Fv

0.4 F , for h / t d380 F


y
w
y

C F
v y

d0.4 F y , for h / t w !380 F y


2.89

Left Col
Right Col
Left Bm
Right Bm

a
10.0
10.0
5.0
5.0

h
16.63
33.50
47.25
47.25

where

h = dL - 2 tf

5.34
, for a / hd1.0
4.0
a / h 2

5.34 4.0
, for a / h !1.0

a / h 2

kv

h / tw
67
134
189
189

0.5

380 / F y
54
54
54
54

Kv
5.42
5.65
7.82
7.82

Cv
0.94
0.28
0.20
0.20

Cv

45000 k v
, for C v d0.8

2
F y h / t w

190
k v , for
C v !0.8
h / t
Fy
w

F bJJ
16.27
4.90
3.41
3.41

DETERMINE ALLOWABLE COMPRESSIVE STRESS (APP. F7.3, pg 5-102)

2
1.0 S F y
where K J =
(effective length factor by an analysis)

2C c2

, for S dC c

S
=
K
l
/
r ox
3
J
5 3S
F aJ 3  8  S 3
2S 2E
C c 8C c

Cc

Fy
2
12S E , for S !
C
c

23 S 2
E=
29000
ksi

Left Col
Right Col
Left Bm
Right Bm

l
11.5
13.2
29.6
39.7

KJ
2.0
2.0
2.5
2.5

Cc
107
107
107
107

Ix
90
464
173
585

A
6.00
9.50
9.25
11.50

r ox
3.87
6.99
4.32
7.13

S
71.14
45.20
205.91
166.97

F aJJ
20.73
25.08
3.52
5.36

CHECK EACH SECTION CAPACITIES


d0

dL

tf

bf

tw

Af

12
22
13
22

17
34
48
48

0.1875
0.25
0.375
0.375

8
8
8
8

0.25
0.25
0.25
0.25

1.5
2
3
3

Section
d (in)
I (in4)
Aw (in2)
N (kips)
V (kips)
M (ft-k)
f a (ksi)

1
12
144
3.00
9.5
-3.55
18.6
1.58

2
14
193
3.42
9.5
-5.55
-29.8
1.48

3
15
251
3.83
9.5
-7.55
-44.7
1.39

4
17
319
4.25
9.5
-9.01
-63.0
1.31

5
25
1225
6.17
24.6
6.84
120.0
2.02

6
36
2979
9.08
24.6
4.56
130.8
1.63

7
48
5760
12.00
24.6
2.86
119.8
1.36

8
39
3588
9.83
24.6
-3.50
148.4
1.55

9
31
2012
7.67
24.6
-9.87
96.0
1.80

10
22
948
5.50
24.6
-16.23
-37.2
2.13

11
30
1463
7.50
18.2
24.55
120.6
1.59

12
26
1042
6.50
18.2
24.55
6.0
1.74

13
22
706
5.50
18.2
24.55
108.6
1.92

F a (ksi)

20.73

20.73

20.73

20.73

3.52

3.52

3.52

5.36

5.36

5.36

25.08

25.08

25.08

f v (ksi)

1.18

1.62

1.97

2.12

1.11

0.50

0.24

0.36

1.29

2.95

3.27

3.78

4.46

F v (ksi)

16.27

16.27

16.27

16.27

3.41

3.41

3.41

3.41

3.41

3.41

4.90

4.90

4.90

f b (ksi)

9.30

12.66

16.34

20.14

14.49

9.57

5.99

9.76

8.79

5.18

14.84

0.90

20.30

F b (ksi)

28.19

28.19

28.19

28.19

30.00

30.00

30.00

30.00

30.00

28.91

25.64

25.64

25.64

Left Col
Right Col
Left Bm
Right Bm

f a < F a [Satisfactory]

f v < F v [Satisfactory]

f b < F b [Satisfactory]

(cont'd)
CHECK COMBINED FLEXURE AND AXIAL FORCE (APP. F7.4, pg 5-104)

fa
4

f b

f a0
f a 0 f bl

4 for
d 0.15

F
F
F
a
J
b
J
aJ

f a0
C m ' f bl

aJ 1 f a 0 F
bJ
L arg er of

F e' J

f a0
f
 bl

0.6 F y F bJ

Left Col
Right Col
Left Bm
Right Bm

f a0
1.58
1.92
1.36
1.36

f bl
20.14
14.84
20.14
14.84

F aJJ
20.73
25.08
3.52
5.36

F bJJ
28.19
25.64
28.68
28.91

for

f a0

1.3

! 0.15

F aJ

F eJJ'
29.51
73.09
3.52
5.36

Cm '
0.95
0.98
0.74
0.81

( fa , fb )
0.79
0.66
1.24
0.81

Technical Reference:
1. AISC: "Manual of Steel construction 9th", American Institute of Steel Construction, 1990.
2. AISC: "Design Guide 25: Frame Design Using Web-Tapered Members, 2010.

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Portal Frame Analysis using Finite Element Method


INPUT DATA & SUMMARY
COLUMN SIZE (WF, Tube, or Pipe)
W18x234

1- 3 =

WF
x-x

ORIENTATION =
2-4=

W18x234

WF

ORIENTATION =

x-x

BEAM SIZE (WF, Tube, or Pipe)


W24X250

3-4=

WF

ORIENTATION =

x-x

DIMENSIONS
H=

15

ft

L=

40

ft

L1 =

10

ft

L2 =

10

ft

L3 =

10

ft

LOADS

DESIGN SECTION FORCES

PL =

81

kips, (downward)

FL =

10

kips, (horiz. to right)

100

ft-kips, (clockwise)

ML =

P1 =

Column

Beam

F1 =

P2 =

79

F2 =

13.5

kips, (horiz. to right)

P3 =

145

kips, (downward)

F3 =

-77

kips, (horiz. to left)

PR =

FR =

MR =

-150
w=

kips, (downward)

BASE (1 & 2) PINNED ?

-183.1

V13 =

79.7

k,(compre.)

N24 =

-131.9

kips

V24 =

26.2

kips

M13 =
N34 =

1130.5

ft-kips

M24 =

371.9

ft-kips

-103.2

k,(compression)

V34 =

130.7

kips

M34, max =

1065.5

ft-kips

HORIZONTAL DRIFT

ft-kips, (anticlockwise)
0.2501

N13 =

'H,3 =

-0.8007 in, (horiz. to left)

'H,4 =

-0.8178 in, (horiz. to left)

BEAM DEFLECTION

1 / 587

'max / L =

kips / ft, (downward)


Yes

, (pinned)

RIGID-ZONE LENGTH FACTOR

75 % of (d / 2)

ANALYSIS
Coordinates (ft)

Reaction (k, ft-k)

Joint J Deflection (in,deg)

Joint

RX

RY

RM

-79.73

183.06

0.00

0.000

0.000

-0.421

40

26.23

131.94

0.00

0.000

0.000

-0.206

15

0.801

-0.016

0.061

40

15

0.818

-0.011

-0.364
0.242

P1/F1

10

15

0.805

-0.392

P2/F2

20

15

0.811

-0.831

0.106

P3/F3

30

15

0.816

-0.722

-0.223

I
(in4)

Length

A
(in2)

End Joint

(ksi)

(ft)

Moment (ft-k)
Mid

Axial
(k)

Shear (k)
J

68.8

4900

29000

14.18

0.00

565.23

1130.45

183.06

-79.73

79.73

68.8

4900

29000

14.18

0.00

-185.96

-371.92

131.94

26.23

-26.23

P1/F1

73.5

8490

29000

9.34

-1027.42

559.32

85.76

89.73

-100.81

100.81

P1/F1

P2/F2

73.5

8490

29000

10.00

-85.76

-402.68

-897.37

89.73

-98.31

98.31

P2/F2

P3/F3

73.5

8490

29000

10.00

897.37

-978.31

-1065.49

103.23

-16.81

16.81

P3/F3

73.5

8490

29000

9.34

1065.49

-452.41

155.23

26.23

130.69

-130.69

k,(compression)

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Web-Tapered Cantilever Frame Design Based on AISC-ASD 9th, Appendix F


DESIGN CRITERIA
1.

IN ORDER TO QUALIFY UNDER THIS DESIGN,


THE FLANGES SHALL BE OF EQUAL AND
CONSTANT AREA. (APP. F7.1.b, page 5-102)
DIAPHRAGM IS NOT BRACING MEMBER, SINCE L IS
DIFFERENT WITH in F1.3, page 5-47.

2.
3.

TOP END FORCES, P & M, SHOULD INCLUDE


IMPACT FACTOR, 1.25, IF THEY ARE FROM MOVABLE
COVER. (A4.2, page 5-29)

INPUT DATA & DESIGN SUMMARY


COLUMN DIMENSIONS

bf =

BEAM DIMENSIONS

bf =

96

in ( 2438 mm )

tf =

in ( 25 mm )

tw =

0.75

in ( 19 mm )

d1 =

780

in ( 19812 mm )

d2 =

700

in ( 17780 mm )

H1 =

200

ft ( 61.0 m )

96

in ( 2438 mm )

tf =

in ( 25 mm )

tw =

0.75

in ( 19 mm )

d3 =

550

in ( 13970 mm )

d4 =
L =

240
323.7

in ( 6096 mm )
ft ( 98.7 m )

H2 =

224.6

ft ( 68.5 m )

BEAM STIFFENER SPACING

a bm =

ft ( 2.4 m )

COLUMN STIFFENER SPACING

a col =

ft ( 2.4 m )

END HEIGHT

UNBRACED LENGTH / PURLIN SPACING

L b,top =

36

UNBRACED LENGTH AT BOTTOM FLANGE

L b,bot =

36

UNBRACED LENGTH AT OUTSIDE OF COLUMN FLANGE


S =
FRAME SPACING
120
ft ( 36.6 m )
STEEL YIELD STRESS
TOTAL GRAVITY LOAD

Fy =
w =
=
w LL =
F =
P =
M =

AVAILABLE LIVE ROAD


LATERAL LOAD
END LOADS

Weight =

STEEL COST

50
36
4.32
21.4
377.6
874.0
70727.6
31.1

ft ( 11.0 m )
ft ( 11.0 m )
L c , outside =

36

ft ( 11.0 m )

N / mm )
ksi (
345
psf ( " - " for wind uplift)
kips / ft ( 63.0 kN / m )
kg / m2 )
psf (
104

THE FRAME DESIGN IS ADEQUATE.

kips ( 1679.4 kN, " - " to left direction )


kips ( 3887.5 kN, " - " to uplift )
ft-kips ( 314596.5 kN-m, " - " to uplift )
2
kg / m )
psf (
152

ANALYSIS
DETERMINE REACTIONS
RH =

377.6

kips

RV =

2272.4

kips

R M = 372568.8 ft-kips

DETERMINE ALLOWABLE FLEXURAL STRESS (APP. F7.4, pg 5-103)

F b

Fy
2
1.0
F y 0.60 F y , for F b > F y / 3
3
6 B F 2s + F 2w
B F 2s +F 2w , for F b F y / 3

where

= MIN[(dL - d0) / d0 , 0.268 L/d0, 6.0]

A f = tf bf

r To
hs

I To = (tf bf + d0 tw / 6) / 12

I To
ATo

= 1.0 + 0.0230

__
3

A To = tf bf + d0 tw / 6

F s

Ld 0
Af

F w

Page 401 of 533


524

12000

h sL d o / A f

170000

( h wL / r To )

(cont'd)

hw

= 1.0 + 0.00385

Column
Beam (+)
Beam (-)

r To

Length
177.1
296.9
296.9

A To
183.50
126.00
126.00

0.11
0.48
0.48

I To
73732
73729
73729

r To
20.05
24.19
24.19

1.75
1.0 + 0.25

Hs
1.15
1.36
1.36

Hw
1.00
1.01
1.01

F s
3.32
8.14
8.14

F w
364.527
524.76
524.76

B
1.61
1.49
1.49

F b
30.00
30.00
30.00

DETERMINE ALLOWABLE SHEAR STRESS (F4, pg 5-49)

0.4 F y , for h / t w380 F y

Fv =

where

CvF y
0.4 F y , for h / t w>380 F y
2.89

Column
Beam

a
8.0
8.0

h = dL - 2 tf
5.34

4.0+
=

kv

h
778.00
548.00

5.34+
0.5

380 / F y
54
54

h / tw
1037
731

45000 k v

, for a / h1.0

( a / h )2

Cv

4.0

, for a / h >1.0

( a / h )2

Kv
354.72
178.00

Cv
0.30
0.30

F y( h / t w )
190
h /tw

, for C v 0.8

k v , for
C v >0.8
Fy

F b
5.13
5.19

DETERMINE ALLOWABLE COMPRESSIVE STRESS (APP. F7.3, pg 5-102)

F a

2
1.0 S 2 F y
2C c
, for S C c
3
5 3S
+
S 3
3 8C c 8C c
12 2E
, for S >C c
23S 2

Column
Beam

l
36.0
36.0

where

(effective length factor by an analysis)

K =

S = K l / r ox
2 2E

Cc

Fy

29000

E=

K
2.0
2.5

Cc
107
107

Ix
3.3E+07
2246400

A
717.00
372.00

r ox
215.18
77.71

ksi
S
4.02
13.90

F a
29.73
28.91

CHECK EACH SECTION CAPACITIES

Column
Beam

Section
d (in)
4
I (in )

d0

dL

tf

bf

tw

Af

700
240

780
550

1
1

96
96

0.75
0.75

96
96

1
2
3
4
5
6
7
8
9
10
11
12
13
780
753
727
700
550
511
473
434
395
356
318
279
240
58862700 53960848 49328151.85 4.5E+07 2.5E+07 2.1E+07 1.7E+07 1.4E+07 1.1E+07 8917696 6839074 5083382 3628800

Aw (in2)
N (kips)
V (kips)
M (ft-k)
f a (ksi)

585.00
2272.4
2272.4
-372569
2.92

3.00

3.08

3.17

0.28

0.28

0.27

0.26

0.24

0.23

0.22

0.20

0.18

F a (ksi)

29.73

29.73

29.73

29.73

28.91

28.91

28.91

28.91

28.91

28.91

28.91

28.91

28.91
4.84

565.00
2272.4
2272.4
-353166

545.00
2272.4
2272.4
-333764

525.00
2272.4
2272.4
-314361

412.50
172.2
2020.4
-222834

383.44
158.9
1876.8
-187184

354.38
145.7
1733.1
-156287

325.31
132.5
1589.5
-130144

296.25
119.2
1445.9
-108754

267.19
106.0
1302.3
-92118

238.13
92.7
1158.7
-80234

209.06
79.5
1015.1
-73104

180.00
66.2
871.5
-70728

f v (ksi)

3.88

4.02

4.17

4.33

4.90

4.89

4.89

4.89

4.88

4.87

4.87

4.86

F v (ksi)

5.13

5.13

5.13

5.13

5.19

5.19

5.19

5.19

5.19

5.19

5.19

5.19

5.19

f b (ksi)

29.6

29.6

29.5

29.4

29.5

27.5

25.6

24.0

22.7

22.1

22.3

24.1

28.1

F b (ksi)

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

f v < F v [Satisfactory]

f a < F a [Satisfactory]

f b < F b [Satisfactory]

CHECK COMBINED FLEXURE AND AXIAL FORCE (APP. F7.4, pg 5-104)

a0

F a

f bl
F b

__

for
f

(fa

f b) =

a0

F a
L arg er of

a0

F a

0.15

C m ' f bl

a0

F e'

f a0
f
+ bl
0.6 F y F b

F b

for

a0

F a

Page 402 of 533


524

> 0.15

1.3

(cont'd)

Column
Beam

f a0
2.92
0.28

f bl
29.62
29.51

F a
29.73
28.91

F b
30.00
30.00

F e'
9262.11
773.12

Cm'
1.00
1.00

( fa , fb )
1.09
0.99

[Satisfactory]

DESIGN STIFFENERS

1. BEARING STIFFENERS ARE REQUIRED AT EACH END SUPPORT. (K1.8, page 5-82)
2. DETERMINE STIFFENER SIZE.
tw =

in

1 1/2

b st / t w =

6.00

A eff =

33.75

in

fa =

25.9

ksi

Es =

29000

ksi

b st =

C c = (2 E s / F y )
2

1
Fa =

0.5

0.5

34.1

( kl / r )

in

< 95 / Fy0.5 , AISC-ASD, B5.1


[Satisfactory]
4
I =
in
927

K / r = 0.75 h / ( I / A eff )

107
2

Fy

2C c2

5 3 ( kl / r ) ( kl / r )
+

3
8C c
8C 3
c
12 2E

23( kl / r )

for

for

kl
Cc
r

26.6

>

kl
> Cc
r

ksi, (AISC-ASD, E2, page 5-42)


fa

[Satisfactory]

DETERMINE STEEL COST AND AVAILABLE ROOF LIVE LOAD

Column
Beam

SW (pcf)
490
490

Flanges (ft 3 )
298.3
250.0

Available Roof Live Load =

Web (ft )
682.6
610.8

36.0

Misc.(ft 3 )
50
50

14.6

psf =

Stiffers (ft )
277.3
248.2

psf -

Technical Reference:
1. AISC: "Manual of Steel construction 9th", American Institute of Steel Construction, 1990.

__
Page 403 of 533
524

TA (ft 2 )
38844
38844

21.4

Weight (lb / ft )
16.5
14.6
31.1
psf

PROJECT :
CLIENT :
JOB NO. :
DATE :
Tube / Pipe Column Design Based on AISC Manual 13th Edition (AISC 360-05)
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION (Tube or Pipe)

HSS12X12X1/2

COLUMN YIELD STRESS


DIMENSION

STRONG AXIS BENDING ? (1=Yes, 0=No)


UNIFORM LATERAL LOAD, ASD
CONCENTRATED LATERAL LOAD, ASD

F=

Tube

Fy =
H =

46
40

ksi
ft

P =

87

kips

AXIAL LOAD, ASD

PAGE :
DESIGN BY :
REVIEW BY :

=>
0
w = 0.06
12.5 kips at

no, weak axis, y-y, bending.


k / ft
29
ft from bottom

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)

P r + 8 M rx + M ry
P c 9 M cx M cy

, for P r 0.2
Pc

M ry
P r 29
+ M rx +
M cx M cy
2Pc

, for P r < 0.2


Pc

Where

KL x =

40

(KL / r)max =
Pr =

87
0.00

M ry =

109.26

<

0.78

ft, for x-x axial load.

<

103

M rx =

200

1.0

KL y =

[Satisfactory]

40

ft, for y-y axial load.

[Satisfactory]

kips
ft-kips, at 29.00 ft from bottom

Pc = Pn / c =

473

/ 1.67 = 283.38 kips, (AISC 360-05 Chapter E)

>

Pr

[Satisfactory]

M cx = M n / b =

343.47 / 1.67 = 205.67 ft-kips, (AISC 360-05 Chapter F)

M cy = M n / b =

343.47 / 1.67 = 205.67 ft-kips, (AISC 360-05 Chapter F)

>
>

M rx
M ry

[Satisfactory]
[Satisfactory]

CHECK LATERAL DEFLECTION

max =

1.89

in, at 21.80 ft from bottom

<
Where

Es =

29000

L /

457

ksi
in4

457

in

240

2.00

in

__
Page 404 of 533
524

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE :
WF Column Design Based on AISC Manual 13th Edition (AISC 360-05)
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION

PAGE :
DESIGN BY :
REVIEW BY :

W10X49

COLUMN YIELD STRESS


DIMENSIONS
AXIAL LOAD, ASD
STRONG AXIS BENDING ? (1=Yes, 0=No)
UNIFORM LATERAL LOAD, ASD
CONCENTRATED LATERAL LOAD, ASD

Fy =
H =

50
14

ksi
ft

P =

35

kips

0
=>
w = 0.75
20
kips at

F=

no, weak axis, y-y, bending.


k / ft
11
ft from bottom

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)

P r + 8 M rx + M ry
P c 9 M cx M cy

, for P r 0.2
Pc

P r + M rx + M ry
2 P c M cx M cy

, for P r < 0.2


Pc

Where

KL x =

14

(KL / r)max =

<

0.90

ft, for x-x axial load.

<

66

Pr =

35

M rx =

0.00

M ry =

59.52

200

1.0

KL y =

[Satisfactory]

14

ft, for y-y axial load.

[Satisfactory]

kips

Pc = Pn / c =

ft-kips, at 11.00 ft from bottom


524

/ 1.67 = 313.64 kips, (AISC 360-05 Chapter E)

>

Pr

[Satisfactory]

M cx = M n / b =

231.22 / 1.67 = 138.46 ft-kips, (AISC 360-05 Chapter F)

M cy = M n / b =

117.92 / 1.67 = 70.609 ft-kips, (AISC 360-05 Chapter F)

>
>

M rx
M ry

[Satisfactory]
[Satisfactory]

CHECK LATERAL DEFLECTION

max =

0.68

in, at 7.40 ft from bottom

<
Where

Es =

L /

272

ksi
in4

y=

93.4

in4

29000

240

0.70

in

__
Page 405 of 533
524

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Wall Stud & Compensation Channel Design Based on AISI S100-2007 & ER-4943P
INPUT DATA & DESIGN SUMMARY
600S162-54

STUD SIZE & SPACING

12
in o.c
( 50 ksi )

WALL DIMENSION

H1 =

14

ft

(H1 or H2 = 0 for stud flr to flr, w/ Bearing or Hanging)

H2 =
H=

1
15

ft
ft

STORY HEIGHT

w = 28.48 psf

SERVICE LATERAL LOAD


WALL GRAVITY LOAD

Wt =

32

psf

H /240

DEFLECTION LIMITS (IBC 06 / CBC 07, Tab. 1604.3)


(1= H /240, 2= H /360, 3= H /180, 4= H /480)

600T200-68
( 14 GA , 50 ksi )
COMPENSATION CHANNEL
CLEAR DISTANCE
CLR =
0.75
in, (for story drift & floor
vertical deflection)

THE DESIGN IS ADEQUATE.


ANALYSIS
SECTION PROPERTIES OF EACH METAL STUD (SSMA page 7 & 8)
thk =

0.0566

in

Fy =

50

ksi

Ixx =

2.86

in4

Mn/b =

27.76 in-kips

t =

in

Wt =

1.89

lb/ft

Sxx =

0.927

in3

Vn/v =

2708

0.556

in2

ry =

0.57

in

A =

rx = 2.267 in

J = 0.000594 in4

50

thk =
wall =

0.0713
6

xo = -1.072 in

6
Cw = 1.318 in

SECTION PROPERTIES OF COMPENSATION CHANNEL (SSMA page 10 & 11)


>
CLR + 1"
t =
2
in, leg length
Fy =

lbs

[Satisfactory]

ksi
in, metal thickness
in, wall thickness

<

channel width

[Satisfactory]

DETERMINE SECTION FORCES


V1 =

0.19

kips/stud

V4 =

0.19

kips/stud

V2 =

-0.21

kips/stud

M1 =

0.60

ft-kips/stud

V3 =
C =

0.21
0.03

kips/stud
M2 =
kips, (the max axial compression)

0.20

ft-kips/stud
T =

x =

0.45

6.50

kips, (the max axial tension)

CHECK WALL STUD MAX WEB DEPTH-TO-THICKNESS RATIO (AISI B1.2)


t / (thk) = 106.01
<
200 [Satisfactory]
CHECK WALL STUD FLEXURAL CAPACITY (AISI C3.1)
Mn/
b =
Where

27.76
in-kips / stud
M = (1/1.4) MAX( M1 , M2) =

>
5.16

M
[Satisfactory]
in-kips / stud, (1/1.4 for wind/seismic, from AISI App. A4.1.2, typical)

CHECK WALL STUD SHEAR CAPACITY (AISI C3.2)


V =
Vn/

2708

Where

lbs / stud

>

V = (1/1.4) MAX( V1 , V2 , V3, V4) =

[Satisfactory]
153 lbs / stud

CHECK WALL STUD CAPACITY COMBINED BENDING & SHEAR (AISI C3.3.1)
bM
Mn

Where

bM
Mn

0.6

vV
Vn

M=
V=

=
5.16
153

<

0.1941

1.0

[Satisfactory]

__
in-kips / stud, (1/1.4 included)
lbs / stud, (1/1.4 included)

Vn/v =

2708

lbs / stud, from SSMA page 7 & 8.

Mn/b =

27.76

in-kips / stud, from SSMA page 7 & 8.

bM
V
+ v
Vn
Mn

<

0.19

0.1678

vV
Vn

0.5

<

1.3

[Satisfactory]

Page 406 of 533


524

0.06

<

0.7

ft

(cont'd)
CHECK WALL STUD COMPRESSION CAPACITY WITH, AT LEAST, ONE FLANGE THROUGH-FASTENED TO SHEATHING (AISI D6.1.3)
Pn/
c =
Where

4.99

kips / stud

c =

1.8

>

Pn = C1C2C3 AE / 29500 =
C1 = (0.79 x + 0.54) =

[Satisfactory]

8.97

kips / stud

0.949

C2 = (1.17 t + 0.93) =

0.996

C3 = (2.5b - 1.63d) + 22.8 =


17.070
E=
29500
ksi (AISI pg xiv)
P=
0.03
kips / stud
CHECK WALL STUD CAPACITY COMBINED AXIAL LOAD & BENDING (AISI C5.2.1)

cP b C mM
+
=
Pn
M n
Where

<

0.19

1.0

[Satisfactory]

M=
P=

5.16
0.03

in-kips / stud, (1/1.4 included)


kips / stud

Pn/c =

4.99

kips / stud

Mn/b =

27.76

in-kips / stud

Cm =

1.0

P Ex =

2E I x

( K x L x )2

= 1

cP
=
P Ex

5782.63 kips / stud

1.000

CHECK WALL STUD DEFLECTION

wall =

Rb
6 EIL

L
b

( x a )3+( L 2b 2 ) x x3

w
24 EI

( L3x 2 L x3+ x 4 )
<

Where

x=
R=
a=
b=

8.00
0.43
1.00
14.00

=
H /240 =

0.26

in
0.75

in

ft, (from max deflection point to short stud end.)


kips, (total floor horizontal reaction.)
ft, (from floor to short stud end.)
ft, (from floor to far stud end.)

CHECK LEG BENDING CAPACITY OF COMPENSATION CANNEL


b =
Mn/
Where

0.36

in-kips / 12"o.c.

M = (1/1.4) V1(CLR + 0.5") =

>
0.17

[Satisfactory]

in-kips / 12"o.c.

Technical References:
1. AISI STANDARD, S100-2007 Edition. American Iron and Steel Institute.
2. SSMA, Product Technical Information, ICBO ER-4943P, Steel Stud Manufactures Association, 2001.

__
Page 407 of 533
524

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Header, Sill & Jamb Design Based on AISI 2001 & ICBO ER-4943P
INPUT DATA & DESIGN SUMMARY
12
ft
b=
h=
5
ft
3
ft
c=
(See Wall Design for Story Height, Lateral Load and More Information.)

OPENING SIZE & LOCATION

HEADER

(flat studs for lateral load)

600S162-54
( 50 ksi studs)

(vert tracks for gravity load)

600T200-54
( 50 ksi tracks)

(TOTAL SECTION: 6 x 6)
wheader =

171

Wt, header =

SILL

plf, (total lateral load on header)


plf, (total gravity load on header, 0 for vertical studs tension above)
600S162-54

(flat stud for lateral load)

( 50 ksi stud)

wsill =

100

JAMB

plf, (total lateral load on sill)


600S162-97

(vert end studs for lateral load)

( 50 ksi studs)

wjamb =

185

plf, (total lateral load on jamb)

Pjamb =

208

lbs, (total axial load)

Jamb End Track ==>

600T125-54

(bent outside track 9.3" min)

( 50 ksi tracks)

THE DESIGN IS ADEQUATE.


ANALYSIS
Header Design
SECTION PROPERTIES OF EACH FLAT STUD (SSMA page 7 & 8)
4

t =

0.0566

in

Fy =

50

ksi

Ixx =

2.86

in

h =

in

Wt =

1.89

lb/ft

Sxx =

0.927

in3

0.556

in2

ry =

0.57

in

A =

rx = 2.267 in

6
Cw = 1.318 in

J = 0.000594 in

L=

12

Mn/b =

27.76 in-kips

Vn/v =

2708

xo = -1.072 in

ft, (header span)

CHECK MAX WEB DEPTH-TO-THICKNESS RATIO (AISI B1.2)


h/t=
106.01
<
200 [Satisfactory]
CHECK HORIZONTAL FLEXURAL CAPACITY (AISI C3.1)
Mn/
b =
Where

4.63

>

ft-kips
2

M = wheader L / 8 =

3.08

[Satisfactory]

ft-kips

CHECK HORIZONTAL SHEAR CAPACITY (AISI C3.2)


Vn/
V =
Where

5.42

>

kips

V = wheader L / 2 =

1.03

[Satisfactory]

kips

CHECK HORIZONTAL LATERAL-TORSIONAL BUCKLING (AISI C3.1.2.2)


Compression Flange Supported ? (0=No, 1=Yes) ==>

0.36C b
Lu =
F yS f

EGJ I y =

Where

Fe =
Where

Cb =

1.0

Sf =
E=
G=

1.91
29500
11300

Iy =

3.077

J=

0.001

C b
K yL yS f

1.09

Ky =

1.0
144

vertical diaphragm on both sides

in3 (total vertical studs, SSMA page 7 & 8.)


ksi (AISI page 18)
ksi (AISI page 21)
in4 (neglecting top & bottom tracks conservatively.)

__
in4

EGJ I y =

Ly =

<

ft

12.6

ksi

in

Page 408 of 533


524

<
<

lbs

2.78 Fy =

139.0

ksi

0.56 Fy =

28.0

ksi

(cont'd)

F y , for F e2.78 F e
10 F y
10
, for 2.78> F e 0.56 F e
F 1
9 y
36 F e
F e , for F e 0.56 F e

Fc =

b =
Mn/

1.20

ft-kips

Where

Sc =

1.91

<

12.6

[Satisfactory]

ksi

<== Does not apply.

in (total vertical studs, SSMA page 7 & 8.)

b =

1.67

Mn =
M=

ScFc =
3.08

24.08
ft-kips

in-kips

CHECK HORIZONTAL CAPACITY COMBINED BENDING & SHEAR AT ANY SAME SECTION (AISI C3.3.1)
bM
Mn

Where

vV
Vn

M=
V=

3.08
1.03

ft-kips
kips

Vn/v =

5.42

kips

b =

<

0.6912

Mn/b =

0.6

[Satisfactory]

7.73

ft-kips

1.67

Mn = MIN( Bending , Buckling) =

bM
Mn

1.0

4.63

>

0.66

bM
V
+ v
Vn
Mn

ft-kips, for bending only.


vV
Vn

0.5

<

0.5882

1.3

0.19

<

0.7

[Satisfactory]

CHECK HORIZONTAL DEFLECTION

Lateral =

5( wheader ) L 4
=
384 EI

0.47

in

<

L /240 =

0.60

in

[Satisfactory]

0.00

in

<

L /240 =

0.60

in

[Satisfactory]

, for (2) - 600T200-54

0.55

in

0.60

in

[Satisfactory]

, for (1) - 600S162-54

CHECK VERTICAL DEFLECTION

5(W t , header ) L 4

Vertical =

384 EI

Where

6.29

in

Sill Design
CHECK HORIZONTAL DEFLECTION

Lateral =
Where

5( wSill ) L 4
=
384 EI
=

2.86

in

<

L /240 =

Jamb Design
SECTION PROPERTIES OF EACH VERTICAL STUD (SSMA page 7 & 8)
0.1017

in

Fy =

50

ksi

Ixx =

4.797

in4

Mn/b =

56.73 in-kips

t =

in

Wt =

3.29

lb/ft

Sxx =

1.599

in3

Vn/v =

11124 lbs

A =

0.966

in2

ry =

0.541

in

thk =

J = 0.003329 in

rx = 2.229 in
6
Cw = 2.093 in

h=

15

xo = -1.039 in

ft, (jamb height)

CHECK MAX WEB DEPTH-TO-THICKNESS RATIO (AISI B1.2)


t / (thk) =
59.00
<
200 [Satisfactory]
CHECK FLEXURAL CAPACITY (AISI C3.1)
Mn/
b =
Where

14.18

ft-kips

M = (1/1.4) Mmax =

CHECK SHEAR CAPACITY (AISI C3.2)


V =
Vn/
Where

33.37

kips

V = (1/1.4) Vmax =

__
>

2.00

>

0.71

[Satisfactory]

ft-kips, (1/1.4 for wind/seismic, from AISI App. A4.1.2, typical)

[Satisfactory]

kips, (see Wall Design diagram for Mmax & Vmax)

Page 409 of 533


524

(cont'd)
CHECK COMPRESSION CAPACITY WITH, AT LEAST, ONE FLANGE THROUGH-FASTENED TO SHEATHING (AISI D6.1.3)
c =
Pn/
Where

25.88

kips

c =

1.8

>

Pn = C1C2C3 AE / 29500 =
C1 = (0.79 x + 0.54) =

P
46.59

[Satisfactory]
kips

0.949

C2 = (1.17 t + 0.93) =

1.049

C3 = (2.5b - 1.63d) + 22.8 =


16.145
E=
29500
ksi (AISI pg xiv)
P=
0.21
kips
CHECK CAPACITY COMBINED BENDING & SHEAR AT ANY SAME SECTION (AISI C3.3.1)
bM
Mn

Where

vV
Vn

<

0.1016

1.0

M=
V=

1.43
0.51

ft-kips, (1/1.4 included)


kips, (1/1.4 included)

Vn/v =

33.37

kips

Mn/b =

14.18

ft-kips

bM
Mn
0.6

<

0.10

bM
V
+ v
Vn
Mn

[Satisfactory]

vV
Vn

0.5

<

0.0755

1.3

<

0.02

0.7

[Satisfactory]

CHECK CAPACITY COMBINED AXIAL LOAD & BENDING (AISI C5.2.1)

cP b C mM
+
=
Pn
M n
Where

0.11

<

1.0

[Satisfactory]

M=
P=

1.43
0.21

ft-kips, (1/1.4 included)


kips

Pn/c =

25.88

kips

Mn/b =

14.18

in-kips

Cm =

1.0

P Ex =

jamb = wall

I
w

wall

w
I

0.34

<

in

H /240 =

0.75

jamb

CHECK BENDING CAPACITY OF TRACK LEG


t =
1.25
in, leg length
Fy =
thk =
wall =

50
0.1132
6

ksi
in, metal thickness
in, wall thickness

<
track width
[Satisfactory]

d =

5
in, jamb width
o
9.3
in, effective width
b = d + 2 t (tan 60 ) =
F =
0.86
kips, (factor 1/1.4 included, AISI App. A4.1.2)
M = F (t + 1/4") / 2 =
0.6
in-kips
2
3
S = b (thk) / 6 =
0.0199 in
Mn/
b =

0.71

( K x H 2 )2

= 1

CHECK DEFLECTION

in-kips

>

[Satisfactory]

__
Page 410 of 533
524

in

2E I x

cP
=
P Ex

[Satisfactory]

29097.14 kips

1.000

PROJECT :
CLIENT :
JOB NO. :
DATE :
Cantilever Column & Footing Design Based on AISC 360-05, ACI 318-08, and IBC 09 1807.3
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION (Tube, Pipe, or WF)

HSS8X8X5/8

COLUMN YIELD STRESS


CANTILEVER HEIGHT

Fy =
H =

46
15

ksi
ft

F=

3.2

kips, ASD

P=

10

kips, ASD

COLUMN TOP LATERAL LOAD


(Strong Axis Bending only)
COLUMN TOP GRAVITY LOAD
DIAMETER OF POLE FOOTING

b=

ft

ALLOW SOIL PRESSURE

Qa =

ksf

LATERAL SOIL CAPACITY


RESTRAINED @ GRADE ?(1=yes,0=no)

PP =

0.35
1

PAGE :
DESIGN BY :
REVIEW BY :

Tube

ksf / ft
Yes

Use 3 ft dia x 4.59 ft deep footing restrained @ ground level

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY OF COLUMN (AISC 360-05, H1)

P r + 8 M rx + M ry
P c 9 M cx M cy

, for P r 0.2
Pc

P r + M rx + M ry
2 P c M cx M cy

, for P r < 0.2


Pc

Where

Pr =

10.00

kips

M rx =

48.00

ft-kips

M ry =

ft-kips

KL y =

30

ft, weak axis unbraced axial length

Pc = Pn / c =

283

[Satisfactory]

Pr

[Satisfactory]

M cx = M n / b =

171.35 / 1.67 = 102.60 ft-kips, (AISC 360-05 Chapter F)

M cy = M n / b =

171.35 / 1.67 = 102.60 ft-kips, (AISC 360-05 Chapter F)

>
>
DESIGN POLE FOOTING (IBC 09 1807.3)
By trials, use pole depth, d =
4.588 ft
Lateral bearing @ bottom, S 3 = 2 P P Min( d , 12' ) =
Lateral bearing @ d / 3, S 1 = 2 P P Min( d / 3 , 12' ) =
Require Depth is given by

A
4.36 h
1+ 1+
2
A
4.25 Ph
bS 3

Where

1.0

/ 1.67 = 169.33 kips, (AISC 360-05 Chapter E)

>

d=

<

0.50

M rx

[Satisfactory]

M ry

[Satisfactory]

3.21

ksf

1.07

ksf

for nonconstrained

4.588

ft

[Satisfactory]

for constrained

P= F=
3.20
A = 2.34 P / (b S 1 ) =

kips
1.72

__

h = M max / F =

15.00 ft

CHECK VERTICAL SOIL BEARING CAPACITY (ACI, Sec. 15.2.2)


2
1.41
ksf, (net weight of pole footing included.)
q soil = P / ( b / 4) =

<

Qa

[Satisfactory]

CHECK STRONG AXIS LATERAL DEFLECTION

FH3
=
3EI

1.47

in

<

2H/

240

Page 411 of 533


524

1.50

in

[Satisfactory]

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

DATE :

PAGE :
DESIGN BY :
REVIEW BY :

Drag / Collector Forces for Brace Frame


DESIGN CRITERIA
1.

NEGLECTING DRAG / COLLECTOR AXIAL DEFLECTIONS, SO THE AXIAL FORCE DIAGRAM AS FOLLOWS IS THE SAME FOR BOTH
RIGID AND FLEXIBLE DIAPHRAGM.

2.

ASSUMING THAT DIAPHRAGM SHEAR STRESS ALONG DRAG ARE UNIFORM AND EQUAL, SINCE THE DIAPHRAGM THICKNESS
SAME AND NAILING OR SHEAR STUD DISTRIBUTED CONTINUOUSLY.

INPUT DATA & DRAG / COLLECTOR AXIAL FORCES


NUMBER OF SEGMENTS / SPAN
Segment Length

n=

Joint

(ft)
Span 1
Span 2

Drag Axial Force, kips

Span 3

10

Distance Horiz. Force


(ft)

Fbrace (k)

Drag Axial Force (kips)


Left

Right

0.00

20

-16.44

-16.44

TOTAL LATERAL FORCE

35

-28.77

-28.77

DIAPHRAGM SHEAR STRESS

50

46.5

-41.10

5.40

Span 5

25

68

46.5

-9.40

37.10

Span 6

20

93

16.55

16.55

Span 7

20

113

0.12

0.12

Span 8

20

133

32

-16.32

15.68

Span 9

18

153

32

-0.76

31.24

Span 10

20

10

171

16.44

16.44

11

191

0.00

60.0
40.0
20.0
0.0
-20.0
-40.0
-60.0

157

ft
kips

vdiaphragm = Fbrace / Ldrag

15
18

191

Fbrace =

15

Span 4

TOTAL DRAG LENGTH


Ldrag =

20

__
Distance, ft

DRAG / COLLECTOR FORCE DIAGRAM

Page 412 of 533


524

822

plf

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Light Gage Truss Design Based on AISI S100-2007 & ER-4943P


INPUT DATA & DESIGN SUMMARY

CONTINUED TOP CHORD (from 0 to 6 & from 6 to 11)

1200S250-97

< == (Total Section: 12 in Ht. x 5 in Thk. )

CONTINUED BOTTOM CHORD (from 0 to 11)

600S250-54

< == (Total Section: 6 in Ht. x 5 in Thk. )

ALL WEB MEMBER SIZE

600S162-54

TRUSS SPAN LENGTH

L=

24

ft

TRUSS DEPTH

H=

ft

SLOPED DEAD LOADS

DL =

300

lbs / ft

PROJECTED LIVE LOADS

LL =

240

lbs / ft

THE TRUSS DESIGN IS ADEQUATE.

ANALYSIS
DESIGN CRITERIA
1. The intermediate finite element analysis include shear deformations using E & G equal to 29500 ksi & 11300 ksi.
2. There are different rotations at same joint of web to chord, since web pinned to continued chord.
3. Top chord shall be fastened to sheathing before vertical laod added.
DETERMINE JOINT DEFLECTIONS BY FINITE ELEMENT ANALYSIS

Joint

DL Deflection (in, deg)


(cont.) (pin-1)

(pin-2)

LL Deflection (in, deg)


(cont.) (pin-1)

(pin-2)

-0.1046

-0.0794

-0.0158

-0.0775

-0.0658

-0.0532

-0.0120

-0.0588

-0.0499

-0.0404

-0.0010

-0.0777

-0.0642

-0.0532

-0.0324

-0.0007

-0.0590

-0.0488

-0.0404

-0.0246

-0.0083

-0.1054

-0.0087

-0.0324

-0.0235

-0.0063

-0.0800

-0.0066

-0.0246

-0.0178

0.0049

-0.1058

-0.0075

-0.0235

-0.0019

0.0037

-0.0803

-0.0057

-0.0178

-0.0015

-0.1049

-0.0019

0.0019

-0.0796

7.22E-17

-0.0015

0.0015

-0.1002

0.0161

-0.0161

-0.0761

0.0122

-0.0122

0.0083

-0.1054

0.0087

0.0324

0.0235

0.0063

-0.0800

0.0066

0.0246

0.0178

-0.0049

-0.1058

0.0075

0.0235

0.0019

-0.0037

-0.0803

0.0057

0.0178

0.0015

0.0158

-0.0775

0.0658

0.0532

0.0120

-0.0588

0.0499

0.0404

10

0.0010

-0.0777

0.0642

0.0532

0.0324

0.0007

-0.0590

0.0488

0.0404

0.0246

11

0.1050

0.1046

0.0797

0.0794

-0.1050

-0.0797

CHECK MAXIMUM LIVE LOAD DEFLECTION


DLL =

0.08

in

<

L / 240

1.20

in

[Satisfactory]

DETERMINE REQUIRED CAMBER AT 1.0 TIMES MAXIMUM DEAD LOAD DEFLECTION


1.0 DDL =

0.11

in

DETERMINE MEMBER FORCES UNDER LOAD COMBINATION (DL + LL)


Joints

__

I end section

J end section

Member

I-J

N (kips)

V (kips)

M(ft-kips)

N (kips)

V (kips)

0-1

-10.952

0.232

0.000

10.952

-0.232

M(ft-kips)
0.928

0-2

12.428

2.649

0.000

-11.724

-0.538

6.718

1-2

0.359

0.000

0.000

-0.359

0.000

0.000

1-3

-10.952

-0.127

-0.928

10.952

0.127

0.422

REACTIONS:

2-3

-1.053

0.000

0.000

1.053

0.000

0.000

R0 = R11 =

2-4

12.680

0.246

-6.718

-11.976

1.864

3.307

3-4

0.366

0.000

0.000

-0.366

0.000

0.000

Page 413 of 533


524

6.67

kips, upward

3-5

-11.951

-0.160

-0.422

11.951

0.160

-0.216

4-5

2.265

0.000

0.000

-2.265

0.000

0.000

10

4-6

10.701

0.271

-3.307

-9.997

1.840

0.000

11

5-6

-2.832

0.000

0.000

2.832

0.000

0.000

12

5-7

-11.951

0.160

0.216

11.951

-0.160

0.422

13

5-8

2.265

0.000

0.000

-2.265

0.000

0.000

14

6-8

9.997

1.840

0.000

-10.701

0.271

3.307

15

7-8

0.366

0.000

0.000

-0.366

0.000

0.000

16

7-9

-10.952

0.127

-0.422

10.952

-0.127

0.928

17

7 - 10

-1.053

0.000

0.000

1.053

0.000

0.000

18

8 - 10

11.976

1.864

-3.307

-12.680

0.246

6.718

19

9 - 10

0.359

0.000

0.000

-0.359

0.000

0.000

20

9 - 11

-10.952

-0.232

-0.928

10.952

0.232

0.000

21

10 - 11

11.724

-0.538

-6.718

-12.428

2.649

0.000

(cont'd)

CHECK LIGHT GAGE MEMBERS CAPACITIES

Member
Top Chord

Mn/b =

30.53

ft-kips

N (kips)

V (kips)

M(ft-kips)

Vn/v =

15.63

kips

-12.680

2.649

6.718

Pn/c =

18.54

kips

Max. Section Force

[Satisfactory]

Member
Bot Chord

Mn/b =

5.33

ft-kips

N (kips)

V (kips)

M(ft-kips)

Vn/v =

5.42

kips

11.951

0.232

0.928

Tn/t =

33.50

kips

Max. Section Force

[Satisfactory]

Compression

Max. Section Force

Web Member

N (kips)

9 & 13

-2.265

V (kips)

M(ft-kips)

Pn/c =

17.88

kips

[Satisfactory]

__
Page 414 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Enhanced Steel Beam Design Based on AISC 14th (AISC 360-10)


INPUT DATA & DESIGN SUMMARY
WF BEAM SECTION

=>

WF BEAM YIELD STRESS


ENHANCING PLATE SIZE

W18X143

=>

rx

ry

Ix

Sx

42.1

19.5

8.08

2.72

2750

282

Fy =
B =

50

ksi

12

in

Iy

tw

bf

tf

tB =

in

311

55.5

0.017

0.73

11.20

1.32

D =
tD =

0
0

in
in

Fy =

36

ksi

A
54.1

d
20.5

y
12.0

Ix
3732

E
29000

Total = = >

Sy

yz
15.02
BEAM SPAN
UNIFORMLY DISTRIBUTED DEAD LOAD
UNIFORMLY DISTRIBUTED LIVE LOAD
CONCENTRATED LOADS
(0 for no concentrated load)

L=
wD =

25.6
0

wL =

3.3

ft
kips / ft
kips / ft

P1,D =

kips

P1,L =

53.2

kips

L1 = 14.25 ft
P2,D =

kips

P2,L =

kips

L2 =

ft

L = L / 360

DEFLECTION LIMIT OF LIVE LOAD


VERTICAL BENDING UNBRACED LENGTH

Lb =

THE BEAM DESIGN IS ADEQUATE.


ft

ANALYSIS
DETERMINE REACTIONS, MOMENT, SHEAR, AND CHECK CAPACITIES
RLeft = 68.18 kips
wSelf Wt = 0.184
kips / ft
VMax =

74.21

<
V allowable =
[Satisfactory]
CHECK LIVE LOAD DEFLECTION
Max =
0.59

RRight = 74.21 kips


MMax = 617.86 ft-kips, at 14.25 ft from left end

kips, at from right end

<
M allowable =
[Satisfactory]

268.83 kips, (from following analysis)

957.97 ft-kips
(from following analysis)

inch, at 13.09 ft, from left end

<

L = L / 360 =

0.85

inch

[Satisfactory]

CHECK LIMITING WIDTH-THICKNESS RATIOS FOR WEB (AISC 360-10 Table B4.1)
23.10
<
r =
137.27
h c / Min(t w , t D ) =

<
where

p =

44.37

Compact Web
r = 5.7 (E / F y ) 0.5 =
137.27

p = (h c / h p ) (E / F y ) 0.5 / (0.54 M p / M y -0.09) 2 =


p = 3.76 (E / F y ) 0.5 =

44.37

90.55

A f,bot

hc =

16.86

in

hp =

27.40

in

My =

1293.3

ft-kips

Mp =

1599.8

ft-kips, (Fy,WF & Fy,Plate may different)

CHECK LIMITING WIDTH-THICKNESS RATIOS FOR FLANGES (AISC 360-10 Table B4.1)
4.24
<
r =
25.09
0.5 b f,top / t f,top =

where

,for A f,top

,for A f,top = A f,bot

r = 1.0 (k c

<
p =
Compact Flanges
E / F L ) 0.5 =
25.09

p = 0.38 (E / F y ) 0.5 =

9.15

9.15

k c = Min [0.76 , Max (0.35 , 4 / (h / t w ) 0.5 )] =


in3
440
S xc =
S xt =
FL =

35

0.76
310

in3

ksi, (AISC 360-10 Table note B4.1 & Eq F4-6)

(cont'd)
DETERMINE ALLOWABLE FLEXURAL STRENGTH , Mn / b , BASED ON AISC 360-10 Chapter F4
E

L p = 1.1r t

L r = 1.95r t

where

7.08

ft

FL

S xc h 0

0.83 , h 0 =

a w =h c t w / (b fc t fc ) =

b fc

rt =

3.21

M p = Min [M p , 1.6S xc F y ] =

R pc =

pw = p =

44.37

= b f / (2 t f ) =

4.24

pf = p =

9.15

,
M

yc

Min

F cr =

for

C b 2E

J=

19.2

in4 (use WF only conservatively)

Cb =

1.0

, (AISC Manual 14th Table 3-1)

M yt = S xt F y =

1320.9 ft-kips

rw = r =

137.27

rf = r =

25.09

h c / t w pw
M

yc

pw

1 + 0.078

Lb
rt

ft

1599.8 ft-kips

23.10

yc

38.32

in

1293.3 ft-kips

= hc / tw =

18.70 in ,

2
1
12 h 0 + a w h
6
d
h 0d

M yc = S xc F y =

S h
1 + 1 + 6.76 F L xc 0
E
J

rw pw

J
S xc h 0

Lb
rt

yc

for

1.237

h c / t w > pw

= 2E+08 ksi, (for I yc / I y

>

0.23, AISC 360-10 F4-5 )

R pc M yc , for L b L p
Lb L p
Lr L p

M n, F 4.2 = Min C b R pc M yc ( R pc M yc F L S xc )

, R pc M yc

, for L p < L b L r

1599.8 ft-kips

Min ( F cr S xc , R pc M yc ) , for L r L b

R pc M yc , for Compact Flanges


R pc M yc ( R pc M yc F L S xc )

M n, F 5.3 =

0.9 E k c S xc

R pt =

yt

Min

b =

for

h c / t w pw

yt

yt

1.67

, for Noncompact Flanges

rf pf

1599.8 ft-kips

, for Slender Flanges

pf

pw
rw pw

yt

for

h c / t w > pw

, (AISC 360-10 F1)

M allowable, F4 = Min( M n,F4.2 , M n,F4.3 , R pt M yt ) / b =

958.0

ft-kips

1.2112

(cont'd)
DETERMINE ALLOWABLE FLEXURAL STRENGTH , Mn / b , BASED ON AISC 360-10 Chapter F5
<== Not Applicable.

Lr = rt

E
0.7 F y

24.18

Fy ,

for

ft

Lb L p

Min C b F y ( 0.3F y )

Lb L p
Lr L p

, Fy

for

L p < Lb L r

F cr , F 5.2 =

=
C b

Min

2E
2

Lb
rt

Fy ,

, Fy

0.9 E k c
2

bf
2t f
R pg = Min 1

ksi

50

ksi

L r Lb

for

for Compact Flanges

F y ( 0.3F y )
F cr , F 5.3 =

50

pf

rf pf

for Noncompact Flanges

for Slender Flanges

Min ( a w , 10 )
hc
5.7
1200 + 300 Min ( a w , 10 ) t w

E
Fy

, 1.0 =

M allowable, F5 = Min( R pg F y S xc , R pg F cr,F5.2 S xc , R pg F cr,F5.3 S xc , F y S xt ) / b =

774.4 ft-kips

DETERMINE ALLOWABLE SHEAR STRENGTH , Vn / v , BASED ON AISC 360-10 Chapter G2


h = d - t f,top - t f,bot =
a =

kv

10.0

5+

in

h / tw =

ft

(a / h)

16.86

, for a / h3

5 , for a / h >3

23

Aw =

2
14.97 in

E
1.0 , for h / t w1.10 k v
Fy

=
5.00

V n = 0.6 F y A w C v =

448.95 kips

V allowable = V n / v =

268.83 kips

Cv

1.10
h /tw

k vE , for 1.10 k vE < h / 1.37 k vE =


tw
Fy
Fy
Fy

E
1.51E k v
, for 1.37 k v < h / t w
Fy

( h / t w )2 F y
v =

1.67

, (AISC 360-10 G1)

1.000

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Enhanced Composite Beam Design Based on AISC 360-05 / IBC 09 / CBC 10


INPUT DATA & DESIGN SUMMARY
FLOOR DECK TYPE
W3-6 1/4" LW
CONCRETE STRENGTH
3
ksi
fc'=
SHEAR STUD DIAMETER (1/2, 5/8, 3/4)
=

3/4

in

STUDS SPACING
1
row @
12
RIBS PERPENDICULAR TO BEAM ?
No
(parallel)

in o.c.

WF BEAM SECTION

=>

WF BEAM YIELD STRESS

W24X62

=>

Fy =

50

ksi

rx

ry

Ix

Sx

23.7

9.23

1.37

1560

132

B =

12

in

Iy

Sy

tw

bf

tf

tB =

in

35

9.8

0.0122

0.43

7.04

0.59

D =
tD =

5
0.5

in
in

Fy, plate =

36

ksi
Total Steel = = >

A
32.8

d
29.7

y
19.3

Ix
3877

E
29000

yz
23.11

Sx
201

Zx
263

ENHANCING PLATE SIZE

30
30

SUPERIMPOSED DEAD LOAD, ASD

L=
S=
wD =

20

ft
ft, o.c.
lbs / ft2

LIVE LOAD

wL =

100

lbs / ft2

CONCENTRATED LIVE LOADS ON BEAM

P1,L =

10

kips

(0 for no concentrated load)

L1 =

10

ft

P2,L =

30

kips

L2 =
== >

20
No

ft
,new construction

BEAM SPAN
BEAM SPACING (TRIB. WIDTH)

TO ENHANCE EXISTING BEAM?

A
18.3

ANALYSIS
DETERMINE REACTIONS, MOMENTS & SHEARS
+(
120
43.50
w = w D+L + w wt =

3.72

RLeft =

91.92

kips

M max =

781.16

ft-kips, at 16.50 ft from left end

THE BEAM DESIGN IS ADEQUATE.


(Camber = 1/4".)

2
167.22 lbs / ft
5.02
kips / ft (total gravity loads on span beam)
RRight = 98.58 kips

) =
=

V max = 98.58 kips, at from right end

CHECK DIMENSION REQUIREMENTS


t0 =
hr =
=

3.25

in

>

in

3/4

in

H s = h r + 1.5 =
s =
12

in o.c.

wr =

in

4.5

in

[Satisfactory]

(AISC 360-05 I3.2c.1.c)

<

in

[Satisfactory]

(AISC 360-05 I3.2c.1.a)

<

3/4

in

[Satisfactory]

in

<

h r + t o - 0.5 =

<
>

MAX[ 8(h r + t o ) , 36 ] =
4 =
3
in o.c.

(AISC 360-05 I3.2c.1.b)


5.75

__
>

in

in

[Satisfactory]

50
in o.c.
[Satisfactory]

[Satisfactory]

(AISC I3.2c.1.b)

[Satisfactory]
(AISC 360-05 I3.2d.6)

(AISC 360-05 I3.2c.1.a)

DETERMINE COMPOSITE PROPERTIES FOR PLASTIC DESIGN


b = MIN (L / 4 , B) =
A ctr =

0.85 f c ' b t 0 / F y =

A fill = A - 2A f - A w =
tw =

0.43

12.23
in

90 in, (AISC 360-05 I3.1a)


2
14.9 in
in2

Page 418 of 533


524

h = t0 + hr + d =

36.0 in, (total height)


in2

A total = A ctr + A =

47.7

Af =

4.15

in2

tf =

0.59

in

(cont'd)

yb =

AF y
h
for Atotal 2 Actr
'b
0.85 f c

d 0.5 Atotal Actr for Atotal 2( Actr + A f


bf
Atotal A f 0.5 A fill

tf+

y =

h
h

thus,

for Atotal 2 A ctr

0.5 t 0 A ctr + 0.5 dA + ( 0.5 A total A ctr ) h d y b


0.5 A total

for Atotal > 2( Actr + A f

tw

0.5 t 0 + h r + y b

32.2

for A total 2 A ctr + A f

in, (plastic neutral axis to bottom)

) (

0.5 t 0 A total + A f t 0 + h r + t f + 0.5 A fill t 0 + h r + 2 t f + t w d y b t f

)( h 0.5 d 0.5 y b + 0.5 t f ) + t w( y b t f )( 0.5 y b + 0.5 t f )

0.5 A total

y =

22.8

for Atotal > 2 A ctr + A f

in, (moment arm between centroid of tensile force and the resultant compressive force.)

Z tr = 0.5 y A total =

in3

544

DETERMINE COMPOSITE PROPERTIES FOR ELASTIC DESIGN


n =

Ec

13.01

A ctr = b t 0 / n =

yb =

, (ACI 318-05 8.5.1)


in2

22.5

Actr ( d + h r + 0.5t 0 )+ 0.5 Ad


=
Actr + A

I tr = I x + A( y b 0.5d ) +
2

S tr =

St =

I tr

22.8

in, (elastic neutral axis to bottom)

2
Actr t 02
+ Actr ( 0.5t 0 + h r + d y b ) =
12

8956

in4

in3, referred to steel bottom.

393

yb

I tr

( d + hr + t 0 yb )

680

in3, referred to concrete top.

CHECK BENDING & SHEAR CAPACITIES


M max = (Z tr / Z x,

Moment :

where

WF )

M DL + M LL =

Zx =

b =

1.67

98.58

kips

1357.0

ft-kips, (AISC 360 I3.2a)

[Satisfactory]

(AISC 360-05 I3.2a)

3.76(E / F y ) 0.5 =
Shear : V max =

1339.6 ft-kips

M n / b = Z tr F y / b =
3
154 in

<

90.55

>

h / tw =

69.07

V n / v = 0.6 F y AwC v / v =

<

196.76 kips, (AISC 360-05 I3.1b)


[Satisfactory]

where

2.24 (E / F y ) 0.5 =
kv =

(k v E / F y ) 0.5 =

53.946
(AISC 360-05 G2.1b)

Cv =

v =

53.852

0.8576 (AISC 360-05 G2.1b)


1.67

(AISC 360-05 G1)

CHECK SHEAR CONNECTOR CAPACITY


M max =
where

781.2

ft-kips

b =

>

1.67

S eff = Min[ M max / (0.66 F y ) , S tr ] =

S eff S s
S tr S s

ft-kips

<== Shear Studs Required

745.88 kips, (AISC 360-05 C-I3.1)


in3, refered to steel bottom.
284

, 0.25 C f = 186.47 kips, (AISC 360-05 C-I3-4)

Q n = MIN [ 0.5 A sc (f c ' E c ) 0.5 , R g R p A sc F u ] =


where

472.8

__

C f = MIN ( 0.85 f c ' A c , F y A s ) =

V ' = MAX

Mn / b = Zx Fy / b =

(AISC 360-05 F1 & F2-1)

wc =

115

X1 =

15.50

18.06

pcf
ft

Page 419 of 533


524

kips, (AISC 360-05 I3.2d.3)

(cont'd)
E c = w c 1.5 33 (f c ') 0.5 =
A sc =

0.44

2229.1 ksi
in2

Fu =

58

Rg =

1.00

(AISC 360-05 Table I3.2b.3)

Rp =

0.75

(AISC 360-05 Table I3.2b.3)

Qn = Qn Nr X1 / s =

ksi

279.99 kips

>

V'

[Satisfactory]

CHECK LIVE LOAD DEFLECTION ON COMPOSITE


Max =
0.35
inch, at 15.5 ft, from left end

<

L = L / 360

1.00

inch

DETERMINE DEAD LOAD DEFLECTION ON NON-COMPOSITE

Mid =

5wDLL4
=
384EI

where

0.31

in

w DL =

1.91

kips / ft

I=

3877

in4

__
Page 420 of 533
524

[Satisfactory]

-. /-%01$ -22$31-4($5.

,6"!

$%067 8019 $0%. 03*-5 % (5%$ -7

# #&! (

# ! ( #:

!
"
# ! # # !
!
$%
! &!
'
! $!
'
()* #! + , ' ! $! # ' ! $ +,
!!
,
$ .
/0 1102 / 34&!
,
!
5
! !
8" !' '
!"
5,
' 6 ,$ # 6 6 ," ! ' 8 9 ! #
,$ ! ! :/); !" &,
#,
'
6 ,$ /1<
&! 8,,
8"8 86 ! ' 8 6 ,
!,# 8 1
= /1< & !
= >)(<

?
/3 )
9

A
?
?

B4

&
B

B
7

?E

#!
#!&

' %#!

(> >

@0 (

5,
6 &.

#!

B
7

$%
&#

?
B
7

(/1

99

#
#

? C9
' %#!&.

A D

/> /

!"

.6 6
5,

," 4

5,

./%1&)%>&3%24

' (

,
,

*
?

&? ?
/0G

C B
+.

4F
F

10G 0

#!I5,
6

1( 2G 5,
6

8 HF

1( 2G

5,
6&! / ,
$!

1( 2G 5,
6

1
/>3 0@ ' %#!
/ >3 5,
6 %#!.! ! $ +,
!-

?
2)

: !,# ! -;

3G0I0) 3 1 / 4

: !,# ! -;

3G0I0) 3 1 / 4

3%2

3%2

: !,# ! -;

3G0I0) 3 1 / '4

: !,# ! -;

!"#

2)

/1

?
.

2 )@

8 HF

J7

(1 )0

% &'()
3
1
,

$ "#

*+ ,
G0
,
,
: !,# ! -;
: !,# ! -;
.

' 84

3 1 / '4

: !,# ! -;
.
3G0I0) 3 1 G4
3G0I0) 3 1 / 4

9
%/0 ) 1- 2
"(#
$4

@0 ,&.
.

$
0 3G

3G0I0) 3 / 4
1
1( ) ,

1
0 0@

1) G ,&.! !
1
2/ 0 ,

,1

,
$ !4

1
3 G( ,

0 G/

13 2

,&.6

!,

"!

H, ! ' !! 84

"#

! "#$% &'#(')$! ("'( "!$ ) *'" +,)!$&


.
.

)$-%

,&$ /01 /
2

21

11

/.

&4 &5 6 % $%- 7 )4 ," &,(,&$!$ )


#
6
8
% 637
)5 15 7 %

%
1

8: 637

"#

<

,$)& .101 -2

57

22.

,$)& .101 -

09

,$)& .101 * 7 *20


.

% '% 637 1) "++

,$)& .101 &0$

,$)& .101 &0$ 0

,
./
)

"#

> >?

: /1

,$)& .101 $ 2

7 &6& 1 221 ,

1
9

!"#

"#

** )

1
9

>

1/

,$)& .101 !

$2

>?

1 .1

,$)& .101 !

$2

0 &! 1

2: 1

;)

<=

&4 &5 )4 ," &'%% &!'" &,(,&$!> *'" +,! ",+ +', )
=

0 1

<=

;)

<=

,$)& .101 $

/2

%/0 ) "(#

;)

1 2/

,$)& .101 -2

,$)& .1 $ 2

:.

"#

91

09

1 9

&4 &5 )4 ," &'%% &!'" &,(,&$!> *'" -",?$!>


% 637
21. 1
09
%

)*1- %/0 ' "#

:1 :
1

:1

;
);

09
.

4"4- )9 1

<

,$)& .101 $ 2

"#

*"8+)9 1
)

22
5

21

;)

<=

&4 &5 &'#6$%

&'#(" ))$'% ,% 6 % $%- &,(,&$!> ,$)& .101 4

1:

;)

@ . B 2

:1 9

A*

< ,$)& .101 &

@
%

:1 /

09

1. 11

;)

<=

;)

<=

,$)& .1 $ 2
%

&4 &5 $%$!$,+

<=

22

*+ &!$'% @&,#6 " ,% )!" )) '% %'%0&'#(')$!


C
A
1 /
9 @
C
D

09

<

1
+#"

% 637
&4 &5 +$? +',

09

57

44+"*

1*+

11

09

;)

*+ &!$'% '% &'#(')$!


1.
9

1 22

"
8
,$)& .101 8E)
2 &6& 21 18E&

)
D&

)
?

6
2

D E,
2E $

$
6

)
D&

;)

&
F

#
<

21

<=

: 211

<=

PROJECT :
CLIENT :
JOB NO. :
Tube, Pipe, or WF Member Capacity Based on AISC 360-05
INPUT DATA & DESIGN SUMMARY
MEMBER SHAPE (Tube, Pipe, or WF) & SIZE

DATE :

HSS2X2X1/4

STEEL YIELD STRESS

Fy =

46

ksi

AXIAL COMPRESSION FORCE

Pr =

kips, ASD

STRONG AXIS EFFECTIVE LENGTH

kL x =

ft

WEAK AXIS EFFECTIVE LENGTH

kL y =

ft

STRONG AXIS BENDING MOMENT

M rx =

0.8
Lb =

STRONG AXIS BENDING UNBRACED LENGTH


V strong =

STRONG DIRECTION SHEAR LOAD, ASD


WEAK AXIS BENDING MOMENT

M ry =
V weak =

WEAK DIRECTION SHEAR LOAD, ASD

PAGE :
DESIGN BY :
REVIEW BY :

1
0.1
1

< ==

Tube

ft-kips, ASD
8

ft, (AISC 360-05 F2.2.c)

kips
ft-kips, ASD
kips

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)

P r + 8 M rx + M ry
P c 9 M cx M cy

, for P r 0.2
Pc

P r + M rx + M ry
2 P c M cx M cy

, for P r < 0.2


Pc

Where

Pc = Pn / c =

<

0.45

1.0

[Satisfactory]

20

/ 1.67 =

12.18 kips, (AISC 360-05 Chapter E)

M cx = M n / b =

3.70

/ 1.67 =

2.21

M cy = M n / b =

3.70

/ 1.67 =

2.21

>
>
>

Pr

[Satisfactory]

ft-kips, (AISC 360-05 Chapter F)


M rx

[Satisfactory]

ft-kips, (AISC 360-05 Chapter F)


M ry

[Satisfactory]

CHECK SHEAR CAPACITY (AISC 360-05, G2)


V n,strong / v =

18.4 / 1.67 =

11.0

kips

>

V strong =

1.0

kips

[Satisfactory]

V n,weak / v =

18.4 / 1.67 =

11.0

kips

>

V weak =

1.0

kips

[Satisfactory]

__
Page 424 of 533
524

PROJECT :
CLIENT :
JOB NO. :
Channel Steel Member Capacity Based on AISC 360-05

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

INPUT DATA & DESIGN SUMMARY


C12X30
CHANNEL SIZE
STEEL YIELD STRESS

Fy =

AXIAL COMPRESSION FORCE

P=

36

ksi

10

kips, ASD

STRONG AXIS EFFECTIVE LENGTH

kL x =

20

ft

WEAK AXIS EFFECTIVE LENGTH

kL y =

10

ft

STRONG AXIS BENDING MOMENT

M rx =

13

ft-kips, ASD

Lb =

STRONG AXIS BENDING UNBRACED LENGTH


V strong =

STRONG DIRECTION SHEAR LOAD, ASD

ft, (AISC 360-05 F2.2.c)

kips

M ry =

ft-kips, ASD

V weak =

35

kips

WEAK AXIS BENDING MOMENT


WEAK DIRECTION SHEAR LOAD, ASD

20

77

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)

P r 8 M rx M ry
+
+
P c 9 M cx M cy

, for P r 0.2
Pc

P r + M rx + M ry
2Pc
M cx M cy

, for P r < 0.2


Pc

Where

0.94

89

/ 1.67 =

53.44 kips, (AISC 360-05 Chapter E)

M cx = M n / b =

42.79

/ 1.67 =

25.62 ft-kips, (AISC 360-05 Chapter F)

M cy = M n / b =

9.84

/ 1.67 =

5.89

Pc = Pn / c =

>
>
>

<

Pr

1.0

[Satisfactory]

[Satisfactory]

M rx

[Satisfactory]

ft-kips, (AISC 360-05 Chapter F)


M ry

[Satisfactory]

CHECK SHEAR CAPACITY (AISC 360-05, G2)


V n,strong / v =

132.2 / 1.67 =

79.2

kips

>

V strong =

77.0

kips

[Satisfactory]

V n,weak / v =

68.6 / 1.67 =

41.1

kips

>

V weak =

35.0

kips

[Satisfactory]

__
Page 425 of 533
524

PROJECT :
CLIENT :
JOB NO. :
Angle Steel Member Capacity Based on AISC 360-05

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

INPUT DATA & DESIGN SUMMARY


ANGLE SIZE
L8X6X1
STEEL YIELD STRESS

Fy =

36

ksi

P=

10

kips, ASD

AXIAL COMPRESSION FORCE

STRONG GEOMETRIC AXIS EFFECTIVE LENGTH

kL x =

20

ft

WEAK GEOMETRIC AXIS EFFECTIVE LENGTH

kL y =

10

ft

STRONG GEOMETRIC AXIS BENDING MOMENT M rx =

ft-kips, ASD
L bx =

STRONG GEOMETRIC AXIS BENDING UNBRACED LENGTH


STRONG DIRECTION SHEAR LOAD, ASD

V strong =

77

kips

M ry =

ft-kips, ASD

60

kips

WEAK GEOMETRIC AXIS BENDING MOMENT

WEAK GEOMETRIC AXIS BENDING UNBRACED LENGTH


WEAK DIRECTION SHEAR LOAD, ASD

V weak =

L by =

20

ft, (AISC 360-05 F2.2.c)

10

ft

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)

P r + 8 M r ,max + M r ,min
P c 9 M c ,max M c,min

, for P r 0.2
Pc

P r + M r ,max + M r ,min
M c,max M c ,min
2Pc

, for P r < 0.2


Pc

Where

Pc = Pn / c =

136

/ 1.67 =

7.78

ft-kips

M r,min =

0.71

ft-kips

or
or

1.0

[Satisfactory]

81.28 kips, (AISC 360-05 Chapter E5)

>
M r,max =

<

0.91

Pr

[Satisfactory]

0.71

ft-kips

,(major principal axis bending)

7.78

ft-kips

,(minor principal axis bending)

M c,max = M n / b =

42.24

/ 1.67 =

25.29 ft-kips, (smaller equal-leg section used, AISC 360-05 Chapter F10-2)

>

M r,max

M c,min = M n / b =

15.89

/ 1.67 =

9.51

ft-kips

>

M r,min

[Satisfactory]
[Satisfactory]

CHECK SHEAR CAPACITY (AISC 360-05, G2)


V n,strong / v =

172.8 / 1.67 =

103.5 kips

>

V strong =

77.0

kips

[Satisfactory]

V n,weak / v =

129.6 / 1.67 =

77.6

>

V weak =

60.0

kips

[Satisfactory]

kips

__
Page 426 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Connection Design for Column above Beam, Based on AISC Manual & AISC 360-05
INPUT DATA & DESIGN SUMMARY
BEAM SIZE

W16X40

COLUMN SIZE

c =
d =

6
6

in
in

3/4
in
1/4
in
3/4
in
ASTM = A325

BASE PLATE THICKNESS


t=
COLUMN TO PLATE WELD
w =
=
BOLT SIZE
BOLT MATERIAL (A307, A325, A490)
COLUMN BASE SERVICE LOADS
P =
V =
M =

Axial
Shear
Moment

10
25
10

kips
kips
ft-kips

Plate Size : 7 in x 10.5 in x 0.75 in


THE CONNECTION DESIGN IS ADEQUATE.

ANALYSIS
CHECK WELD OF COLUMN TO BASE PLATE (AISC 360-05 J2.4 )
fx = V / Aw =

5.7

ksi

fy = P / Aw + M / Sw =
fv = (fx2 + fy2)0.5 =
Where

20.1
20.9

Aw =

4.4

ksi
in2

Sw =

6.7

in3

ksi
Fv = 0.6 FEXX / =

<

21.0

ksi

[Satisfactory]

CHECK SHEAR BOLTS CAPACITY


Rnv / =

42.4

kips, (AISC Manual 13th, Table 7-1)

>

[Satisfactory]

CHECK TENSION BOLTS FLANGE CAPACITY


d' = + 1/16 =
0.813 in

19.9
Rnt / =
1.299 in
'
= 1 d =
2.049 in
S
in, (AISC Manual 9th, Page 4-90)

b' = b - 0.5 =
a' = a + 0.5 =
S=
9.000
tc =

8 Bb '
=
SF y

Fy =

0.678

50

' =

ksi, for WF

R n / = R nt / Min 1 , 1.3

Rn /
T allow = R n /

tc
t
tc

(1 + )

fv
F nv

1
'

1+ b'

tc
t

14.1

(1 + )
'

1.48

1 =

0.538

, for ' > 1


, for 0 ' 1

11.7

kips / bolt, (AISC Manual 9th, Page 4-89 to 4-95)


T = - P / 4 + 0.5 M / (1.5 + c) =
5.5
[Satisfactory]

CHECK BASE PLATE BENDING CAPACITY


Edge =
1.500 in, (AISC 360-05, Tab J3.4 & J3.5)
Base Plate Size =
7
in x
10.5
in x

36

kips / bolt, (AISC 360-05, J3.7)

>

Fy =

0.910

'
R n / , for < 0

Mn / b =

kips / bolt, (AISC Manual 13th, Table 7-2)

__

ft-kips, (AISC 360-05 Chapter F)

ksi, for Base Plate

Page 427 of 533


524

3/4

kips / bolt

in

>

M=

1.38

[Satisfactory]

ft-kips

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Design for Fully Restrained Moment Connection across Girder Based on AISC 360-05
INPUT DATA & DESIGN SUMMARY
WF BEAM SECTION
GRAVITY SERVICE VERTICAL LOAD
BALANCED SERVICE MOMENT
VERTICAL PLATE THICKNESS

= > W21X50
P =
47
kips
26
ft-kips
M =
t V = 0.75 in

HORIZONTAL PLATE THICKNESS

tH =

PLATE STEEL YIELD STRESS


TRIAL WELD SIZE
BOLT DIAMETER
BOLT MATERIAL (A307, A325, A490)
HOLE TYPE (STD, NSL, OVS, SSL, LSL)
STD =
NSL =
OVS =
SSL =
LSL =

36
ksi
0.5 in ( 1/2 in)
1
in ( 1 in)
A325
STD

Standard round holes ( d + 1/16 " )


Long or short-slotted hole normal to load direction
Oversize round holes
Short-slotted holes
Long-slotted holes

CONNECTION TYPE (SC, N, X)


SC

0.375 in

Fy =
w=
=
ASTM =
=>

=>

USE VERT. PLATE 9.5" x 4.0" x 3/4" WITH WELD 1/2" EA. SIDE TO
GIRDER WEB & 1 ROW OF TOTAL (3) - 1" BOLTS AT BEAM END.

HORIZ. TOP PLATE THK. 3/8" WITH 2 ROW 2 BOLTS PER ROW AT ONE END.

= Slip critical connection

= Bearing-type connection with threads included in the shear plane

= Bearing-type connection with threads excluded from the shear plane

TRY VERTICAL BOLTS


1
row &
IS TOP FLANGE COPED ? (1=Yes, 0=No,)
HORIZONTAL BOLTS
2
rows &

3
=>
2

bolts per row, (total 3 bolts.)


1
Yes
bolts per row, (total 4 bolts at one end.)

ANALYSIS
BEAM SECTION PROPERTIES (AISC 13th Table 1)
tf
k
d
tw
20.8
0.38
0.535
1.04
CHECK CAPACITY OF VERTICAL BOLTS (AISC 360-05 J3)
Allow shear per bolt

18.8

kips / bolt, (Rn / v, AISC 13th Table 7)

T = 2 M / d = coupling force
No. of bolts required
Bolt spacing required
Edge spacing required
Number of rows required

=
=
=
=
=

30
3.0
3.00
1.75
1

kips
in
in, (Tab J3.4)
rows

Bolt group capacity

57

kips

CHECK CAPACITY OF VERTICAL WELDING (AISC 360-05 J2)


e
=
Plate thickness
=
Weld size,w
=
Min allowable weld
=
Max allowable weld
=
=
te
D
=
I = 2 ( te D3 / 12 )
=

(P2 + T2 )0.5

2.25
0.75
0.50
0.25
0.69
0.35
9.5

Bolt spacing used


Edge spacing used
Number of rows used

>
>

(P2 + T2 )0.5
P =

=
47

50.5

in, (AISC 360-05, Table J3.4)


in
in
in
[Satisfactory]
in
[Satisfactory]
in
in
in4

Vertical shear = P / Aw = P / 2 D te
Bending stress = 0.5 P e D / I

=
=

7.0
9.9

ksi
ksi

Tension stress =

4.5

ksi

T / Aw = T / 2 D te

Resultant Stress = [ (P/Aw)2 + (0.5 P e D / I + T/Aw)2 ]0.5 =


Allow shear Fw / = (0.6 x 70 ksi) / 2.0 =

=
=
=
=
=

Number of bolts used

21.0

16.0

>

CHECK VERTICAL PLATE FOR SHEAR CAPACITY (AISC 365-05 G2)


P/A =
6.6
ksi <
0.6 Fy Cv / v = 0.6 Fy 1.0 / 1.5 =

21.56

kips
bolts
in
in
rows

kips

56
kips
[Satisfactory]

ksi

[Satisfactory]

ksi

ksi

CHECK VERTICAL PLATE FOR TENSION CAPACITY (AISC 365-05 D)


T/A=
4.2
ksi <
Fy / t = Fy / 1.67 =

56
3
3.00
1.75
1

14.4

ksi

16.0

ksi

[Satisfactory]

[Satisfactory]

__

CHECK VERTICAL NET SHEAR FRACTURE (AISC 360-05 J4.2)


=
58
ksi ( AISC Manual 13th Edition, Pg. 2-39)
Fu
Pallow = 0.6 Fu / [ D - n (ds + 1/8 ) ] tV

80

kips

>

47

kips

[Satisfactory]

133

kips

>

30

kips

[Satisfactory]

CHECK VERTICAL NET TENSION FRACTURE (AISC 360-05 J4.1)


=
58
ksi
Fu
Tallow = Fu / [ D - n (ds + 1/8 ) ] tV

Page 428 of 533


524

[Satisfactory]
[Satisfactory]
[Satisfactory]
[Satisfactory]

(cont'd)
CHECK BLOCK SHEAR ( WEB TEAR-OUT, AISC 360-05 J4) <== Applicable only for top flange coped.
lh
=
1.3
in
lv

5.3

in

Fu

65

ksi ( for WF, AISC Manual 13th Edition, Pg. 2-39)

Rbs,P = 0.6 Av Fu / + At Fu / = (0.3 lv + 0.5 lh) tw Fu


Rbs,T = (0.5 lv + 2 x 0.3 lh) tw Fu

83

=
>
T=

>

54
P=
30

kips
47.00 kips
kips

[Satisfactory]
[Satisfactory]

CHECK CAPACITY OF HORIZONTAL BOLTS (AISC 360-05 J3)


Allow shear per bolt
=
18.8
Bolt group capacity

75

kips / bolt, (Rn / v, AISC 13th Table 7)

>

kips

CHECK HORIZONTAL PLATE FOR TENSION CAPACITY (AISC 365-05 D)


T/A=
13.3
ksi <
Fy / t = Fy / 1.67 =

21.56

T =

30

ksi

kips

[Satisfactory]

[Satisfactory]

CHECK HORIZONTAL NET TENSION FRACTURE (AISC 360-05 J4.1)


=
58
ksi
Fu
Tallow = Fu / [ 6" - 2 (ds + 1/8 ) ] tH

41

kips

>

30

kips

[Satisfactory]

CHECK BLOCK SHEAR ( TOP FLANGE TEAR-OUT, AISC 360-05 J4)


lt
=
1.9
in
lv

5.6

in

Fu

65

ksi ( for WF, AISC Manual 13th Edition, Pg. 2-39)

Rbs,T = (0.5 lt + 0.3 lv) tf Fu

91

>

T=

30

__
Page 429 of 533
524

kips

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Beam Bolted Splice Design Based on AISC Manual 13th Edition (AISC 360-05)
INPUT DATA & DESIGN SUMMARY
WF BEAM SECTION

(Flange Plate 5.71 in x 19.5 in x 1 in)


=>

WF STEEL YIELD STRESS

W21X48

Fy =

50

ksi

PLATE STEEL YIELD STRESS

F yp =

36

ksi

FLANGE PLATE THICKNESS

t fp =

in

t wp =

0.75

in

WEB PLATE THICKNESS


BEAM AXIAL LOAD, ASD

T =

70

kips, ( 20% WF's Pn / t)

VERTICAL SHEAR FORCE, ASD

V =

100

kips, ( 69% WF's Vn / v)

MOMENT AT SPLICE, ASD

M =

80

ft-k, ( 30% WF's Mn / b)

=
1
BOLT DIAMETER
BOLT MATERIAL (A307, A325, A490)
HOLE TYPE (STD, NSL, OVS, SSL, LSL)
STD =
NSL =
OVS =
SSL =
LSL =

in ( 1 in)
ASTM =
=>

Standard round holes ( d + 1/16 " )


Long or short-slotted hole normal to load direction
Oversize round holes
Short-slotted holes
Long-slotted holes

CONNECTION TYPE (SC, N, X)


SC
N
X

A325
STD

=>

(Web Plate 9.5 in x 13.5 in x 0.75 in)


N

THE DESIGN IS ADEQUATE.

= Slip critical connection


= Bearing-type connection with threads included in the shear plane
= Bearing-type connection with threads excluded from the shear plane

FLANGE BOLTS
WEB BOLTS

2
2

rows
vert rows

3
3

bolts on each row (total 6 bolts at each end)


bolts on each row (total 6 bolts at each end)

ANALYSIS
SECTION PROPERTIES (AISC 13th Table 1)
d
20.6

tw
0.35

tf
0.43

k
0.93

DETERMINE PLATE DIMENSIONS


Bolt spacing required
Edge spacing required
Flange Plate
Web Plate

bf
8.14

A
14.1

Zx
107

=
=

3.00
1.75

in, (Tab J3.3)


in, (Tab J3.4)

Bolt spacing used


Edge spacing used

<

bf

<

d - 2k - 2t f

5.71

in

L fp

19.5

in

9.5

in

L wp

13.5

in

R n / v

=
=

3.00
1.75

in
in

[Satisfactory]
[Satisfactory]

[Satisfactory]
[Satisfactory]

CHECK CAPACITY OF BOLTS (AISC 360-05 J3)


Allowable shear capacity

18.8

kips / bolt, (AISC 13th Table 7)

Flange bolt shear

v = T / AT + M / S =

Web bolt shear

v = [(T / A T ) 2 + (V / A V ) 2 ] 0.5 =
AT =
S=
AV =

where

11.7

kips / bolt
17.1

<

R n / v [Satisfactory]

k / bolt

<

R n / v [Satisfactory]

18
bolts, (total one end bolts)
123.6 in-bolts, (flange bolts only)
6
bolts, (one end web bolts only)

CHECK WEB PLATE FOR SHEAR CAPACITY (AISC 365-05 G2)


14.0
ksi < 0.6 F yp C v / v = 0.6 F yp 1.0 / 1.5 =
V / (D t wp ) =
CHECK FLANGE PLATE FOR TENSION CAPACITY (AISC 365-05 D)
11.9
ksi
T / (2 B t fp + D t wp ) + M / (d B t fp ) =

<

14.4

F yp / t = F yp / 1.67 =

CHECK FLANGE NET TENSION FRACTURE (AISC 360-05 J4.1)


=
58
ksi ( for plate, AISC Manual 13th Edition, page. 2-39)
F up
0.5 T + M / d =
81.60
kips
<
F up / [ B - n (d s + 1/8 ) ] t fp =

__

ksi

[Satisfactory]

21.56 ksi

100

kips

CHECK FLANGE NET SHEAR FRACTURE (AISC 360-05 J4.2)


=
65
ksi ( for WF, AISC Manual 13th Edition, page. 2-39)
Fu
0.5 T + M / d =
81.60
kips
<
0.6 Min( F u t f , F up t fp ) / ( shear length) =

[Satisfactory]

[Satisfactory]

82.80
kips
[Satisfactory]

CHECK WEB PLATE BLOCK SHEAR (AISC 360-05 J4)


=
4.9
in
lh
lv
V =

=
100.00

1.2
kips

in
<

0.6 A v F up / + A t F up / = (0.3 l v + 0.5 l h ) t wp F up =

Page 430 of 533


524

122.89 kips
[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Filled Composite Column Design Based on AISC 360-05 & ACI 318-08
INPUT DATA & DESIGN SUMMARY
STEEL SHAPE (Tube or Pipe) & SIZE

PAGE :
DESIGN BY :
REVIEW BY :

HSS10X8X1/2

STEEL YIELD STRESS

Fy =

46

ksi

CONCRETE STRENGTH

fc' =

ksi

AXIAL COMPRESSION FORCE

Pr =

100

< ==

kips, ASD

STRONG AXIS EFFECTIVE LENGTH

kL x =

40

ft

WEAK AXIS EFFECTIVE LENGTH

kL y =

ft

STRONG AXIS BENDING MOMENT

M rx =

15

ft-kips, ASD

Lb =

STRONG AXIS BENDING UNBRACED LENGTH


STRONG DIRECTION SHEAR LOAD, ASD

WEAK DIRECTION SHEAR LOAD, ASD

40

ft, (AISC 360-05 F2.2.c)

V strong =

50

kips

M ry =

20

ft-kips, ASD

V weak =

30

kips

WEAK AXIS BENDING MOMENT

Tube

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK FILLED COMPOSITE COLUMN LIMITATIONS (AISC 360-05, I2.2a)
A steel / A total =
Where

15.3

in2

A total =

78.3

in2

b/t=

<

16.00

D/t=
Where

>

0.20

A steel =

N/A
b=
D=
t=

8.0
N/A
0.5

1.0%

[Satisfactory]

2.26 (E / F y ) 0.5 =

56.75

0.15 E / F y =
in

94.57
E=

29000

[Satisfactory]

ksi

in

CHECK COMPRESSION CAPACITY (AISC 360-05, I2.2b)


Pc = Pn / c =
Where

142.77

kips

>

c =

2.0

C2 =

0.85

P0 =

C3 =

0.90

Pe =

Pn =

Pr

[Satisfactory]

285.54 kips
918

kips

325.59 kips

CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05 I1.1b & I4, and ACI 318-08 Chapter 9 & 10)
o =

2 0.85 f
Ec
0.85 f

'
C

'
C

, E c = 57

c
c

2
o
o

, E s = 29000ksi

'
C

for 0 < c < o

, for c o
s E s , for s t
fS=
f y , for s > t
0.85 f

'
C

C=

5.45

Pc = Pn
Mc = Mn
Where

b =

/
/

b =

in
100

kips

86

ft-kips

>

b =

1.67

Pn =

b =

0.9

Mn =

M u / ( b / b ) = (M rx 2 + M ry 2 ) 0.5 =
167

25.0

kips

ft-kips
[Satisfactory]

143.1 ft-kips

CHECK SHEAR CAPACITY (AISC 360-05, I2.2d & G2)


V n,strong / v =

184.0 / 1.67 =

110.2 kips

>

V strong =

50.0

kips

[Satisfactory]

V n,weak / v =

147.2 / 1.67 =

88.1

>

V weak =

30.0

kips

[Satisfactory]

kips

PROJECT :
CLIENT :
JOB NO. :
Cellular Beam Design Based on AISC 360-05
INPUT DATA & DESIGN SUMMARY
W21X83
BEAM SIZE
CELL DIAMETER
CELL PITCH ( 1.25 D to 1.5 D)

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

D=
S=

6
9

in
in

STEEL YIELD STRESS

Fy =

50

ksi

AXIAL COMPRESSION FORCE

Pr =

60

kips, ASD

( 12% steel weight saved.)

STRONG AXIS EFFECTIVE LENGTH

kL x =

28

ft

WEAK AXIS EFFECTIVE LENGTH

kL y =

ft

STRONG AXIS BENDING MOMENT

M rx =

50

ft-kips, ASD

Lb =

STRONG AXIS BENDING UNBRACED LENGTH


V strong =

STRONG DIRECTION SHEAR LOAD, ASD


WEAK AXIS BENDING MOMENT
WEAK DIRECTION SHEAR LOAD, ASD

THE DESIGN IS ADEQUATE.

ft, (AISC 360-05 F2.2.c)

25

kips

M ry =

10

ft-kips, ASD

V weak =

200

kips

ANALYSIS
CHECK FULL SECTION CAPACITY, AT WEB OPENING, USING STRAIN-COMPATIBILITY METHOD (AISC 360-05, H1)

P r + 8 M rx + M ry
P c 9 M cx M cy

, for P r 0.2
Pc

P r + M rx + M ry
2 P c M cx M cy

, for P r < 0.2


Pc

Where

Pc = Pn / c =

867

[Satisfactory]

Pr

[Satisfactory]

682.82 / 1.67 = 408.88 ft-kips, (AISC 360-05 Chapter F)

>
M cy = M n / b =

1.0

/ 1.67 = 519.32 kips, (AISC 360-05 Chapter E)

>
M cx = M n / b =

<

0.31

125.43 / 1.67 =

M rx

[Satisfactory]

75.11 ft-kips, (AISC 360-05 Chapter F)

>

M ry

[Satisfactory]

CHECK T-SHAPE CAPACITY AT WEB OPENINGS (AISC 360-05, H1)


0.5 (b f - t w ) / t f =
dT / tw =

14.95

4.70

<

<

0.75 (E / F y ) 0.5 =

P r + 8 M r ,x + M r , y
P c 9 M c, x M c, y

, for P r 0.2
Pc

P r + M r ,x + M r , y
2Pc
M c, x M c, y

, for P r < 0.2


Pc

Where

Pc = Pn / c =

1.0 (E / F y ) 0.5 =

341

/ 1.67 =

0.97

54.64

/ 1.67 =

M c,y = M n / b =

62.69

/ 1.67 =

<

[Satisfactory]
[Satisfactory]

1.0

(AISC 360-05, Table B4.1)

[Satisfactory]

203.99 kips, (AISC 360-05 Chapter E4a or D2)

>
M c,x = M n / b =

24.08
18.06

0.5 P r =

30.00

kips

[Satisfactory]

32.72 ft-kips, (AISC 360-05, F9)

>

0.5 M r,x =

25.00

ft-kips

[Satisfactory]

37.54 ft-kips, (AISC 360-05, F6)

>

0.5 M r,y =

5.00

ft-kips

[Satisfactory]

CHECK SHEAR CAPACITY (AISC 360-05, G2)


V n,strong / v =

237.9 / 1.67 =

142.5 kips

>

V strong =

V n,weak / v =

418.8 / 1.67 =

250.8 kips

>

V weak =

25.0

kips

[Satisfactory]

200.0 kips

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
Double Angle Capacity Based on AISC 360-05
INPUT DATA & DESIGN SUMMARY
DOUBLE ANGLE SIZE
LONG LEGS BACK TO BACK ?
GAP DIMENSION

Yes

STITCHES SPACING

DATE :

2 - L8X6X1
(LLBB)
s = 0.375 in

kL z =

ft, o.c.

Fy =

36

ksi

STEEL YIELD STRESS

PAGE :
DESIGN BY :
REVIEW BY :

AXIAL FORCE (plus sign for compression)

80

P=

kips, ASD

STRONG GEOMETRIC AXIS EFFECTIVE LENGTH

kL x =

20

ft

bf =

12.4

in

tf =

1.0

in

WEAK GEOMETRIC AXIS EFFECTIVE LENGTH

kL y =

10

ft

d=

8.0

in

yp =

1.50

in

A =

22.0

in2

Ix =

162

in4

y=

3.14

in

Iy =

179

in4

35
ft-kips, ASD,
STRONG GEOMETRIC AXIS BENDING MOMENT M rx =
DOUBLE LEGS TENSION ?
Yes
(back to back legs tension)
STRONG GEOMETRIC AXIS BENDING UNBRACED LENGTH
STRONG DIRECTION SHEAR LOAD, ASD

L bx =

20

V strong =

200

kips

M ry =

15

ft-kips, ASD

150

kips

ft, (AISC 360-05 F9.2 & F2.2.c)

THE DESIGN IS ADEQUATE.


WEAK GEOMETRIC AXIS BENDING MOMENT

WEAK GEOMETRIC AXIS BENDING UNBRACED LENGTH


V weak =

WEAK DIRECTION SHEAR LOAD, ASD

L by =

10

ft

ANALYSIS
CHECK LIMITING WIDTH-THICKNESS RATIOS (AISC 360-05, Table B4.1)
0.5 (b f - s - t w ) / t f =
d / tw =

4.00

5.00

<

<

1.0 (E / F y ) 0.5 =

0.75 (E / F y ) 0.5 =

28.38
21.29

[Satisfactory]
[Satisfactory]

CHECK COMBINED COMPRESSION AND BENDING CAPACITY FOR DOUBLE ANGLES (AISC 360-05, H1)

P r + 8 M r ,x + M r , y
P c 9 M c, x M c, y

, for P r 0.2
Pc

P r + M r ,x + M r , y
2Pc
M c, x M c, y

, for P r < 0.2


Pc

Where

Pc = Pn / c =

270

0.99

<

1.0

[Satisfactory]

/ 1.67 = 161.41 kips, (AISC 360-05 Chapter E4a or D2)

>

Pr =

80.00

kips

M c,x = M n / b =

159.68 / 1.67 =

95.62 ft-kips, (AISC 360-05, F9)

M c,y = M n / b =

129.00 / 1.67 =

77.25 ft-kips, (AISC 360-05, F6)

[Satisfactory]

>
>

M r,x

[Satisfactory]

M r,y

[Satisfactory]

CHECK COMBINED COMPRESSION AND BENDING CAPACITY FOR SINGLE ANGLE BETWEEN STITCHES (AISC 360-05, H1)

P r + 8 M r ,max + M r ,min
P c 9 M c ,max M c,min

, for P r 0.2
Pc

P r + M r ,max + M r ,min
2Pc
M c ,max M c ,min

, for P r < 0.2


Pc

Where

Pc = Pn / c =

256

0.96

<

1.0

[Satisfactory]

/ 1.67 = 153.09 kips, (AISC 360-05 Chapter E5)

>

Pr =

43.50

kips

[Satisfactory]

(Conservatively, P r is single angle possible maximum axial load, which may be non-concurrent with moments.)
M r,max =

5.30

ft-kips

or

5.30

ft-kips

,(major principal axis bending)

M r,min =

5.30

ft-kips

or

5.30

ft-kips

,(minor principal axis bending)

M c,max = M n / b =

44.40

/ 1.67 =

26.58 ft-kips, (smaller equal-leg section used, AISC 360-05 Chapter F10-2)

>

M r,max

M c,min = M n / b =

15.89

/ 1.67 =

9.51

ft-kips

[Satisfactory]

>

M r,min

[Satisfactory]

CHECK SHEAR CAPACITY (AISC 360-05, G2)


V n,strong / v =

345.6 / 1.67 =

206.9 kips

V n,weak / v =

259.2 / 1.67 =

155.2 kips

>
>

V strong =

200.0 kips

[Satisfactory]

V weak =

150.0 kips

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
T-Shape Member Capacity Based on AISC 360-05

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

INPUT DATA & DESIGN SUMMARY


T-SHAPE SIZE

bf =

12

in

tf =

2.74

in

d=

11.2

in

tw =

1.52

in

STEEL YIELD STRESS

50

Fy =

AXIAL FORCE (plus sign for compression)

10

P=

20

ft

WEAK GEOMETRIC AXIS EFFECTIVE LENGTH

kL y =

10

ft

70

STRONG GEOMETRIC AXIS BENDING UNBRACED LENGTH

L bx =

300

kips

M ry =

150

ft-kips, ASD

WEAK GEOMETRIC AXIS BENDING UNBRACED LENGTH


WEAK DIRECTION SHEAR LOAD, ASD

V weak =

y=

2.94

in

1.91

Ix =

387

in
in4

Iy =

397

in4

L by =
500

THE STEM IN TENSION ?

ft-kips, ASD,

V strong =

WEAK GEOMETRIC AXIS BENDING MOMENT

in2

kips, ASD

kL x =

STRONG GEOMETRIC AXIS BENDING MOMENT M rx =

45.7

yp =
ksi

STRONG GEOMETRIC AXIS EFFECTIVE LENGTH

STRONG DIRECTION SHEAR LOAD, ASD

A =

Yes

20

ft, (AISC 360-05 F9.2 & F2.2.c)

10

ft

(stem tension)

kips

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK LIMITING WIDTH-THICKNESS RATIOS (AISC 360-05, Table B4.1)
0.5 (b f - t w ) / t f =
d / tw =

7.37

1.91

<

<

1.0 (E / F y ) 0.5 =

0.75 (E / F y ) 0.5 =

24.08
18.06

[Satisfactory]
[Satisfactory]

CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)

P r 8 M r ,x M r , y
P r 0.2
+
+

, for

Pc
P c 9 M c, x M c, y

P r M r ,x M r , y
P r < 0.2
+
+
, for

2
P
M
M
Pc
c, y
c c, x
Where

Pc = Pn / c =

1386

<

0.96

1.0

[Satisfactory]

/ 1.67 = 829.85 kips, (AISC 360-05 Chapter E4a or D2)

>

Pr =

10.00

kips

M c,x = M n / b =

312.64 / 1.67 = 187.21 ft-kips, (AISC 360-05, F9)

M c,y = M n / b =

431.36 / 1.67 = 258.30 ft-kips, (AISC 360-05, F6)

>
>

[Satisfactory]

[Satisfactory]

M r,x

[Satisfactory]

M r,y

CHECK SHEAR CAPACITY (AISC 360-05, G2)


V n,strong / v =

510.7 / 1.67 =

305.8 kips

>

V strong =

300.0 kips

[Satisfactory]

V n,weak / v =

986.4 / 1.67 =

590.7 kips

>

V weak =

500.0 kips

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Sleeve Joint Connection Design, for Steel Cell Tower / Sign, Based on AISC 360-10
INPUT DATA & DESIGN SUMMARY
SMALL PIPE

D (in)
20

Fy (ksi)
42

t (in)
0.25

BIG PIPE

D (in)
24

Fy (ksi)
42

t (in)
0.25

RING PLATE (Top, Middle, & Bottom)

SLEEVE LENGTH

t (in)
0.75

L=

JOINT HORIZONTAL SECTION FORCES


P=
V=
M=
T=
SIZE OF FILLET WELD ALL AROUND
w=
SLOT WELDS

Fy (ksi)
36

30

in

15
39
50
30

kips, (Axial)
kips, (Shear)
ft-kips, (Bending)
ft-kips, (Torsion)

in

0.1875

6
- 5/8 in x
3
in
(Side Welds @ 60 deg. O.C.)

THE CONNECTION DESIGN IS ADEQUATE.


ANALYSIS
CHECK FILLET WELD LIMITATIONS (AISC 360-10 J2.2b)
>
w=
0.1875
in

wMIN =

0.125 in

<

wMAX = (I 0.6 Fu t) / (I 0.707 FEXX) = (0.75 x 0.6 x 58 ksi) t / (0.75 x 0.707 x 70 ksi)
[Satisfactory]
= 1.1795 t = 0.295 in
CHECK FILLET WELD CAPACITY (AISC 360-10 J2.4)
fx = V / Aw + T / (0.5 D Aw) =
9.00
fy = P / Aw + M / Sw =
f = (fx2 + fy2)0.5 =
Where

16.11

20

in, use small pipe conservatively


0.1326 in

Aw =

D S te =

[Satisfactory]

41.92541 in

14.83

kips / slot weld

kips / slot weld

f = (Fx2 + Fy2)0.5 / Aw =
n =
D =
Aw =

ksi

S [(D + 2 te) - D ] / 32(D + 2 te) =


2.0

2.50

21.00

8.3291 in
4

CHECK SLOT WELD CAPACITY (AISC 360-10 J2.4)


Fx = V / n + T / (0.5 n D) + M / (n L) =

Where

0.6 FEXX / : =

ksi

0.707 w =

Fy = P / n =

<

18.46

D =
te =
Sw =
: =

ksi
ksi

8.02

ksi

<

0.6 FEXX / : =

21.00 ksi

[Satisfactory]

17.40 ksi

[Satisfactory]

6
24

, number of slot welds


in, big pipe diameter
2
1.875 in / slot weld
5/8 in x 3 in =

CHECK SHEAR RUPTURE CAPACITY OF RING PLATE (AISC 360-10 J4.2)


f = (Fx2 + Fy2)0.5 / Aw =
Where

Fu =
: =

8.02
58
2.0

ksi

<

0.6 Fu / : =

ksi, ( AISC Manual 14th Edition, Tab. 2-4)

CHECK BLOCK SHEAR CAPACITY OF SLOTTED PIPE (AISC 360-10 J4.3)


f = (Fx2 + Fy2)0.5 / Aw =
Where

Fu =
U =
Aw =

8.30

ksi

<

Min (0.6 Fu , U Fu) / : =

58
ksi, ( AISC Manual 14th Edition, Tab. 2-4)
0.5
,not 1.0 conservatively
2
1.813 in / slot weld
2 t ( 5/8 in + 3 in ) =

14.50 ksi

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Moment Connection Design for Beam to Weak Axis Column Based on AISC 360-10
DESIGN CRITERIA
1.
The moment load, M, is supported by top and bottom flanges, and the
vertical load, P, by beam web. But the axial load, T, may be supported
by flanges/web, or by both, so the design conservatively double
accounts that the axial load fully by both flanges and web.
The additional thickness of connection plates and/or shims may
2.
be used to accommodate tolerances for fabrication.
INPUT DATA & DESIGN SUMMARY
WF BEAM SECTION
MOMENT LOAD, ASD
VERTICAL SERVICE LOAD, ASD
HORIZONTAL TENSION LOAD, ASD
PLATE THICKNESS
PLATE STEEL YIELD STRESS
WELD SIZE
BOLT DIAMETER
BOLT MATERIAL (A307, A325, A490)
HOLE TYPE (STD, NSL, OVS, SSL, LSL)
STD =
NSL =
OVS =
SSL =
LSL =

= > W24X94
M =
75
ft-kips
P =
43
kips
T =
60
kips
t = 0.625 in
Fy =
50
ksi
w=
0.5
in ( 1/2 in)
I =
in ( 1 in)
1
ASTM = A325
=>
STD

Standard round holes ( d + 1/16 " )


Long or short-slotted hole normal to load direction
Oversize round holes
Short-slotted holes
Long-slotted holes

CONNECTION TYPE (SC, N, X)


SC
N
X

=>

SC

THE DESIGN IS ADEQUATE.

= Slip critical connection


= Bearing-type connection with threads included in the shear plane
= Bearing-type connection with threads excluded from the shear plane

2
rows &
WEB BOLT NO.
WEB PLATE EXTENDED DIMENSION
2
rows &
EACH FLANGE BOLT NO.

7
bolts per row, (total 14 bolts.)
7.11 in
a =
3
bolts per row, (total 6 bolts.)

ANALYSIS
BEAM SECTION PROPERTIES (AISC Manual Table 1)

d
24.3

tw
0.515

tf
0.875

k
1.38

bf
9.07

CHECK CAPACITY OF WEB BOLTS (AISC 360-10 J3)


Allow shear per bolt

(P2 + T2 )0.5 =
No. of bolts required
Bolt spacing required
Edge spacing required
Number of rows required
Bolt group capacity

11.5

74
=
=
=
=

kips
6.4
3.00
1.25
2

161

CHECK CAPACITY OF WEB PLATE WELDING (AISC 360-10 J2)


e , (including a )
=
Plate thickness
=
Weld size,w
=
Min allowable weld
=
Max allowable weld
=
te
=

kips / bolt, (Rn / :v, AISC Manual Table 7)


Number of bolts used

in
in, (Tab J3.4)
rows

Vertical shear =

2.5

=
=

Bending stress

= 0.5 P e d / I

Tension stress =

T / Aw = T / 2 d t e

=
10.2

>

=
43

=
=
=
=

kips

14
3.00
1.25
2

M = Pe =

37.1

ft-k

42.5
<

in, (AISC 360-10, Table J3.4)


in
in
in
[Satisfactory]
in
[Satisfactory]
in
54.372 deg, (AISC 360-10, J2-5)

ksi

'u =

0.0378 in

6.4

ksi

'm =

0.0288 in

3.5

ksi

f(p) =

1.1898 , (AISC 360-10, J2-9)

Fw =

68.28 ksi, (AISC 360-10, J2-8)

34.1
ksi

10.2

ksi

ksi
[Satisfactory]

ksi

Fcr Z / : =

[Satisfactory]
[Satisfactory]
[Satisfactory]
[Satisfactory]

74
kips
[Satisfactory]

CHECK WEB PLATE FLEXURE CAPACITY WITH VON-MISES REDUCTION (AISC Manual, page 10-103)
D
=
20.5
in
fv = [(P/A)2 + (T/A + 6Pe / tD2 )2 ]0.5 =
15.2 ksi
Fcr = (Fy2 - 3 fv2 )0.5 =

bolts
in
in
rows

T=

Resultant Stress = [ (P/Aw)2 + (0.5 P e d / I + T/Aw)2 ]0.5 =


Allow shear Fw / : = Fw / 2.0

(P2 + T2 )0.5
P =

4
845.4 in

I = 2 ( te d3 / 12 )
P / A w = P / 2 d te

Number of rows used

>
>

kips

10.36
0.63
0.50
0.25
0.56
0.35

Bolt spacing used


Edge spacing used

139.2 ft-k

CHECK WEB PLATE FOR SHEAR CAPACITY (AISC 360-05 G2)


P/A =
3.4
ksi <
0.6 Fy Cv / :v = 0.6 Fy 1.0 / 1.5 =

[Satisfactory]

20

ksi

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Seismic Bi-axial Moment Frame Design Based on AISC 358-10 & ACI 318-11

PAGE :
DESIGN BY :
REVIEW BY :

DESIGN CRITERIA
Concrete-filed 16 in. square HSS or Built-up box column (AISC 358-10 Chapter 10) is the first bi-axial bending column which can be used
in seismic moment frames based on all versions of UBC/IBC/CBC (2010 CBC 2205A.5 & 2013 CBC 2206A.2). The beam to column
connection (Collar/Bolts) can directly be purchased from the ConXtech ConXL (AISC Fabricator Certified Plant). But because bi-axial bending
capacity is lower than about each principal axis, the bi-axial strong column-weak beam conditions have also to be checked based on ACI 318-11
filled composite capacity.
INPUT DATA & DESIGN SUMMARY
COLUMN SIZE
b=h=
t=

16
2.25

in, out-of width


in, web thickness

COLUMN STEEL YIELD STRESS

Fy =

50

ksi

CONCRETE STRENGTH

fc' =

ksi

BEAM
W24X103
BEAM STEEL YIELD STRESS
BEAMS AT ONE JOINT (2, 3, or 4)

Fy =
n=

50
4

ksi
, 4 - beams connected

BEAM LENGTH

24

L=

ft

T =

SEISMIC CHECK DIRECTION TO PRINCIPAL FRAME

45

deg.

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK BEAM LIMITATIONS (AISC 358-10, I0.3.1 & AISC 341-10 Table D1.1)
W24X103
>
W18
<
W30
tf =
0.98
<
1.0
in
bf =

9.00

L/d=

11.76

bf / (2tf ) =

4.59

<
>
<

12.0

in

7
0.3 (Es / Fy)0.5 =

7.22

[Satisfactory]

CHECK COLUMN LIMITATIONS (AISC 358-10, I0.3.2 & AISC 341-10 Table D1.1)
t =
2.25
>
0.375 in
b =
16.00
>
16
in
fc' =
5.00
>
3
ksi
2.26 (E / F y ) 0.5 =

<

5.11

(b -2t) / t =

54.43

[Satisfactory]

CHECK BI-AXIAL STRONG COLUMN-WEAK BEAM CONDITION AT T DIRECTION (AISC 358-10, I0.3.8, ACI 318-11 Chapter 10 & 21)
6Mnc =
where

3003.7 ft-kips
(ACI 318-11 21-1)
6Mnc =

Mnc @ Pu/ I =

fC

128

2 0.85 f

Mnc

1501.9

Pu =

Ho

 6Mnb =
[Satisfactory]

>

'
C

, Ec

Ec

2941.1

ft-kips

, top & bottom columns

ft-kips

kips, (A g f c ' /10 suggested, ACI 318-11 21.6.1)


'

57 f C , E s

Pn

29000ksi
8000




0.85 f 'C 2 H c  H c , for 0  H c  H o

H o H o

'

0.85 f C , for H c t H o

H s E s , for H s d H t
f
, for H s ! H t

6000
4000
2000
0
0

500

1000

1500

2000

-2000
-4000
-6000

-8000

Solid Line - Tension Controlled


Dash Line - Compression Controlled

6Mnb = [

Mnb = Fy ZRBS =
ZRBS =

Cos T +

866.5
280

Cos (90 - T ) ] Mnb =

2450.9

ft-kips, at

T direction

ft-kips, about principal axis. (AISC 358-10 10.8, C pr & R y not apply to ACI 318)
in3, (AISC 318-10 10.3.1.6)
72.03
=
207.97

2500

Mn

PROJECT :
CLIENT :
JOB NO. :
DATE :
Thin Composite Beam/Collector Design Based on AISC 360-10 & ACI 318-11

PAGE :
DESIGN BY :
REVIEW BY :

DESIGN CRITERIA
Top flange within concrete can drag heavy diaphragm force to lateral
frames, reduce floor system depth of composite steel-concrete, and
not need shear studs. But if axial in tension the flexure capacity reduced.
INPUT DATA & DESIGN SUMMARY
BEAM/COLLECTOR SECTION

W21X44

STEEL YIELD STRESS

Fy =

50

ksi

CONCRETE STRENGTH

fc' =

ksi

CONCRETE COVER

Cc =

t0 =

4.25

THE DESIGN IS ADEQUATE.

in, 0.75" min., (ACI 318-11 7.7)


in, 2.20 Min.
30
ft
28
ft, o.c.
Pu =
80

kips, SD level, at center of W21X44

STRONG AXIS POSITIVE MOMENT, LRFD

Mu =

380

ft-kips, SD level

SHEAR LOAD, LRFD

Vu =

75

kips, SD level

BEAM/COLLECTOR SPAN
SPACING (Tributary Width)
COLLOCTOR AXIAL LOAD, LRFD

L=
B =

ANALYSIS
DETERMINE CAMBER/SHORING ON NON-COMPOSITE
w=
2.497
kips / ft, floor system self weight, to W21X44, on non-composite
' = 5wL 4 / 384 EI =
1.86
in, deflection of W21X44
<
L / 180
=
2.00
in
[Satisfactory]
Camber =
0.75 ' =
1.40 in

CHECK FLEXURAL & AXIAL CAPACITY (AISC 360-10, I3, ACI 318-11 Chapter 10 & 21)

Ho

fC
H

2 0.85 f 'C

Ec

, Ec

'

57 f C , E s

29000ksi

H H 2
'
c  c , for 0 

Hc Ho

0.85 f C 2

H o H o

'

0.85 f C , for H c t H o

H s E s , for H s d H t
f
, for H s ! H t

Pn
2500

2000

1500

b = MIN (L / 4 , B) =
90
in, (AISC 360-10 I3.1a)
I =
0.9
, (AISC 360-10 I3)
Mn @ Pu/ I =
475.8
ft-kips

IMn =

1000

428.2

>
500

ft-kips
M u + 0.5C c P u =

[Satisfactory]

0
0

500

1000

1500

2000

Mn

-500

Solid Line - Tension Controlled


Dash Line - Compression Controlled
CHECK SHEAR CAPACITY (AISC 360-10, G2)
IVn =
195.6
kips

>

Vu =

75.0

kips

[Satisfactory]

383.3

ft-kips

(cont'd)
CHECK WEB PLATE FOR TENSION CAPACITY (AISC 365-05 D)
T/A=
4.7
ksi <
Fy / :t = Fy / 1.67 =

29.94

ksi

[Satisfactory]

CHECK WEB NET SHEAR FRACTURE (AISC 360-10 J4.2)


Fu
=
70
ksi ( AISC Manual, Pg. 2-39)
Pallow = 0.6 Fu / : [ D - n (ds + 1/8 ) ] t

166

kips

>

43

kips

[Satisfactory]

276

kips

>

60

kips

[Satisfactory]

CHECK WEB NET TENSION FRACTURE (AISC 360-10 J4.1)


Fu
=
70
ksi
Tallow = Fu / : [ D - n (ds + 1/8 ) ] t

CHECK CAPACITY OF EACH FLANGE BOLTS (AISC 360-10 J3)


One flange bolt group capacity =
69

kips

>

CHECK EACH FLANGE PLATE FOR TENSION CAPACITY (AISC 365-05 D)


(M / d + 0.5 T) / A =
11.83
ksi < Fy / :t = Fy / 1.67 =
CHECK FLANGE NET SHEAR FRACTURE (AISC 360-10 J4.2)
Vallow = 0.6 Fu / : [ 1.5 + 3 (n - 1) - n (ds + 1/8 ) ] 2 tmin

(M / d + 0.5 T) =

29.94

89
>

67
kips
[Satisfactory]

ksi

[Satisfactory]

kips
67

kips

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Bolt Connection Design Based on AISC Manual 14th Edition (AISC 360-10)
INPUT DATA & DESIGN SUMMARY
STEEL YIELD STRESS

Fy =

SIDE PLATE THICKNESS

ts =

50

Ab =
E2 =

in

tb =

0.5

in

E1 =

in

T =
e =

59
1

BASE PLATE THICKNESS

TOTAL AXIAL LOAD, ASD

BOLT DIAMETER
I =
BOLT MATERIAL (A307, A325, A490)
HOLE TYPE (STD, NSL, OVS, SSL, LSL)

ksi

0.375 in by
1
One Side
in2, (Total Section Area)
5

kips, (Single Shear)

in, (to bolts center)

in ( 1 in)
ASTM =
=>

A325
STD

STD = Standard round holes ( d + 1/16 " )


NSL = Long or short-slotted hole normal to load direction
OVS = Oversize round holes

THE DESIGN IS ADEQUATE.

SSL = Short-slotted holes


LSL = Long-slotted holes

CONNECTION TYPE (SC, N, X)


SC
N
X

=>

= Slip critical connection


= Bearing-type connection with threads included in the shear plane
= Bearing-type connection with threads excluded from the shear plane

BOLTS NUMBER
MINIMUM BOLT SPACING

Rows

2
3

s =

ANALYSIS
CHECK DIMENSION LIMITATIONS (AISC 360-10 J3)
Bolt spacing required
=
Edge spacing required
=
CHECK BOLT CAPACITY (AISC 360-10 J3)
Maximum single bolt shear

Columns, (Total
in

3.00
1.75

Bolts)

in, (Tab J3.3)


in, (Tab J3.4)

<
<

3
in
Min(E 1 ,E 2 )

[Satisfactory]
[Satisfactory]

v = (T / 6 ) x 1.67 =

16.4
<

kips / bolt

R n / :v =

18.8

kips / bolt, (AISC 14th Table 7)

Allowable shear capacity

[Satisfactory]

CHECK NET TENSION FRACTURE OF SIDE PLATE (AISC 360-10 J4.1)


F up =
58
ksi ( for plate, AISC Manual 14th Edition, page. 2-39)
(F up / : ) [ A b - Col ( I + 1/8 ) t s ] =

126

kips

CHECK BASE PLATE BLOCK SHEAR (AISC 360-10 J4)


0.6 A v F up / : + A t F up / : =
135 kips
>
6 v = T x 1.67 = 98
[Satisfactory]
in2, (Total Shear Area)
6.1875
Where
Av =
At =

0.94

0.70

kips

in2, (End Tension Area)

CHECK SIDE PLATE BLOCK SHEAR (AISC 360-10 J4)


0.6 A v F up / : + A t F up / : =
101 kips
>
6 v = T x 1.67 = 98
[Satisfactory]
in2, (Total Shear Area)
Where
Av =
4.64
At =

>

in2, (End Tension Area)

kips

[Satisfactory]

PROJECT :
PAGE :
CLIENT :
DESIGN BY :
JOB NO. :
DATE :
REVIEW BY :
Cantilever Column System (SCCS/OCCS) Design Based on AISC 341-10/360-10 & ACI 318-14
INPUT DATA & DESIGN SUMMARY
COLUMN SHAPE (Square Tube or Pipe) & SIZE
H=

D=

22
P=

GRAVITY LOAD

< == Tube

HSS9X9X5/8

ft
in, Embedment Depth
kips, ASD level

LATERAL LOAD

kips, SD level

F=

20

(1=SCCS, 2=OCCS, 3=Wind) ==>

STEEL YIELD STRESS

Fy =

50

ksi

CONCRETE STRENGTH

fc' =

ksi

:0 =

1.25

, ASCE 7 Tab. 12.2-1

THE DESIGN IS ADEQUATE.

ANALYSIS
CHECK LIMITING WIDTH THICKNESS RATIO (AISC 341-10 E5.5a, E6.5a, & Tab.D1.1)
0.038 Es / Fy

<

0.5
0.55 (Es / Fy)

b/t=

12.4

where

t=

0.625

in

b=

7.75

in

22.040

13.246

<== Not Apply

[Satisfactory]

CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 341-10 E5.4a, E6.4a & AISC 360-10 H1)

P r 8 M rx
P r t 0.2


, for
P rc
P rc 9 M cx

P r  M rx , for P r  0.2

2P
P rc
rc M cx
Where

0.99

3.42

M rx = 0.7 : 0 F H =

140.00

ft-kips, ASD level

144.96

ft-kips

M cx = M n / : b =

[Satisfactory]

kips, ASD level, (ASCE 7-10 12.4.3.2)

P r = (1 + 0.14 S DS ) P =
P rc = 15% (P n / : c ) =

1.0

<

66.50

kips

>
>

M rx

Pr

[Satisfactory]

[Satisfactory]

CHECK BASE FIXED MOMENT CONDITION (ACI 318 21 & 22)


kips, SD level, (ASCE 7-10 12.4.3.2)
Vu = :0 F =
25.00
Mu = :0 F H =

200.00

ft-kips

250
200
I Vn (k)

150
100

50
0
0

50

100

150

200

250

I Mn (ft-k)
I Mn =

Ho

2f

'
C

Ec

0.85Min

0.85Min

0.85Min

A2
A1

, 2 , E c

A2 , 2
f
A1

'
C

A2 , 2
f
A1

'
C

57

0u =

ft-kips @ Vu =
200

'
C

H H 2
2 c  c ,
H o H o
,

204

>

for H c t H o

25

kips

ft-kips
[Satisfactory]

I Vn,max =
for 0  H c  H o

>
where

193.90
Vu =

kips, when C =

15.1 in

25

[Satisfactory]

ft-kips

I=
0.65
, (ACI 318 21.2)
Bearing factor = 2, (ACI 318 14.5.1.1)
b = effective bearing width = 95%

bf =

8.55

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Non-Prismatic Composite Girder Design Based on AISC 360-10 / 2013 CBC / 2015 IBC
INPUT DATA & DESIGN SUMMARY
GIRDER SECTION
=>

W24X55

FLOOR DECK TYPE

W3-6 1/4" LW

=>

A
16.3

=>

d
23.6

Ix
1360

Sx
115

Zx
135

REDUCED DIMENSION (one end or both ends)


60
in
X =
10
in
Y=
GIRDER SPAN
GIRDER SPACING (TRIB. WIDTH)

28
L=
21
B =
w BM = 55.47
N=
2
P = 30.417
No
Fy =
50

GIRDER SELF WEIGHT, ASD


NUMBER OF EQUAL POINT LOAD
EQUAL POINT LOAD, ASD
RIBS PERPENDICULAR TO GIRDER ?
GIRDER YIELD STRESS

fc'=

CONCRETE STRENGTH
SHEAR STUD DIA. (1/2, 5/8, 3/4)
1
STUDS SPACING

I =
row @
(Total Studs 20 )

ft
ft, o.c.
lbs / ft

kips @ 9.33" o.c.


(parallel)
ksi

ksi

3/4
18

in
in o.c.

THE GIRDER DESIGN IS ADEQUATE.


USE C = 0.92" AT MID GIRDER.
ANALYSIS
DETERMINE REACTIONS, MOMENTS & SHEARS
R = 0.5 (w BM L + N P) =
31.19

kips

M max = 0.5 R L - 0.125 w BM L 2 - 6 (P D i ) =


M red = R X - 0.5 w BM X 2 =

155.3

V max = R =

kips

31.19

CHECK DIMENSION REQUIREMENTS


3.25
in
t0 =
hr =
I =

289.3

>

in

[Satisfactory]

(AISC 360-10 I3.2c)

in

<

in

[Satisfactory]

(AISC 360-10 I3.2c)

3/4

in

<

3/4

in

[Satisfactory]

H s = h r + 1.5 =
s=
18

in o.c.

wr =

in

4.5

h r + t o - 0.5 =

A fill = A - 2A f - A w =
0.40

0.30

(AISC 360-10 I3.2c)

in

<

<
>
>

MAX[ 8(h r + t o ) , 36 ] =
50
in o.c. [Satisfactory]
4 I=
3
in o.c.
[Satisfactory]
(AISC 360-10 I3.2d)
2
in
[Satisfactory]
(AISC 360-10 I3.2c)

DETERMINE COMPOSITE PROPERTIES FOR PLASTIC DESIGN


b = MIN (L / 4 , B) =
84
in, (AISC 360-10 I3.1a)
2
A ctr =
0.85 f c ' b t 0 / F y =
13.9 in
tw =

ft-kips, at middle of girder

ft-kips, at reduced section

in2

in

5.75

y =

17.0

Z tr = 0.5 y A total =

[Satisfactory]

h = t0 + hr + d =

30.2

Af =

3.54

in2

tf =

0.51

in

in, (plastic neutral axis to bottom)

in, (moment arm between centroid of tensile force and the resultant compressive force.)

257

in3

(AISC I3.2c)

29.9 in, (total height)


in2

A total = A ctr + A =

23.4

thus,

in

(cont'd)
DETERMINE COMPOSITE PROPERTIES FOR ELASTIC DESIGN
13.01
A ctr = b t 0 / n =

, (ACI 318-14 19.2.2.1)


in2

21.0

21.0

in, (elastic neutral axis to bottom)

3853
in3, referred to steel bottom.

183

438

in3, referred to concrete top.

CHECK BENDING & SHEAR CAPACITIES


Middle Bottom :
M max = (Z tr / Z x ) M DL + M LL =

:b =

1.67

w deck =

90.55

43.50 lbs / ft

Steel ==>

where
Shear : V max =

Z tr =
31.19

>

h / tw =

A
12.4

d
13.6

[Satisfactory]

59.75

Ix
369.4

Sx
54.3

Zx
62.0

Aw
5.4

222.6 ft-kips

M n / : b = Z tr F y / : b =
3
152 in
kips

ft-kips, (AISC 360 I3.2a)

M red = (Z tr / Z x ) M DL + M LL =
<

640.1

(AISC 360-10 I3.2a)

3.76(E / F y ) 0.5 =

Reduced Section :

366.8 ft-kips

M n / : b = Z tr F y / : b =

<
where

in4

380.5

ft-kips, (AISC 360 I3.2a)

[Satisfactory]

95.679 kips, (AISC 360-10 I3.1b)

<

[Satisfactory]
where

2.24 (E / F y ) 0.5 =
kv =

(k v E / F y ) 0.5 =
CHECK SHEAR CONNECTOR CAPACITY
M max =
289.3
ft-kips
where

:b =

1.67

53.946
(AISC 360-10 G2.1b)

Cv =

:v =

53.852

Mn / :b = Zx Fy / :b =

<

336.8

696.15

S eff = Min[ M max / (0.66 F y ) , S tr ] =

105

kips, (AISC 360-10 C-I3.1)


in3, referred to steel bottom.

174.04

kips, (AISC 360-10 C-I3-5)

Q n = MIN [ 0.5 A sc (f c ' E c ) 0.5 , R g R p A sc F u ] =


wc =

115

18.06

2229.1

kips, (AISC 360-10 I3.2d)

in2

Fu =

58

ksi

Rg =

1.00

(AISC 360-10 Table I3.2b)

Rp =

0.75

(AISC 360-10 Table I3.2b)


168.59

kips

<

V'

CHECK INITIAL DEFLECTION / CAMBER AND STRESS ON NON-COMPOSITE


I =
DL =
75%
Self Weight
w DL =
41.60
lbs / ft
Zx =
P DL =
e=

6.78
0.036

<== No Shear Stud Required

ksi

0.44

6Qn = Qn Nr X1 / s =

(AISC 360-10 G1)

pcf

E c = w c 1.5 33 (f c ') 0.5 =


A sc =

1.67

(AISC 360-10 F1 & F2-1)

C f = MIN ( 0.85 f c ' A c , F y A s ) =

where

ft-kips

0.9915 (AISC 360-10 G2.1b)

kips @ 9.33" o.c.


L=
0.92

[Satisfactory]

369.4
62.0

in4, reduced section conservatively.


in3, reduced section conservatively.

28.00 ft
in, downward at middle of girder.
USE C = 0.92" AT MID GIRDER.

(cont'd)
M max =

68.7

ft-kips

<

CHECK LIVE LOAD DEFLECTION ON COMPOSITE


P=
23.63
kips
0.79

Mn / :b = Zx Fy / :b =

I tr =

154.7

ft-kips

4
1402.6 in , reduced section conservatively.

in, downward at middle of girder.

<

L / 360 =

0.93

in

[Satisfactory]

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Low-rise Building, Based on ASCE 7-2010


INPUT DATA
Exposure category (B, C or D, ASCE 7-10 26.7.3)
Importance factor (ASCE 7-10 Table 1.5-2)

Basic wind speed (ASCE 7-10 26.5.1 or 2012 IBC)


Topographic factor (ASCE 7-10 26.8 & Table 26.8-1)

Iw =
V =
Kzt =

1.00
136
1

Building height to eave

he =

11

ft

Building height to ridge


Building length
Building width
Effective area of components (or Solar Panel area)

hr
L
B
A

18
100
50
28

ft
ft
ft
ft2

=
=
=
=

for all Category


mph
Flat

DESIGN SUMMARY
Max horizontal force normal to building length, L, face
Max horizontal force normal to building length, B, face
Max total horizontal torsional load
Max total upward force

=
=
=
=

28.80
18.51
339.07
133.04

kips, SD level (LRFD level), Typ.


kips
ft-kips
kips

ANALYSIS
Velocity pressure

qh = 0.00256 Kh Kzt Kd V2
where:

34.21 psf

qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316)
Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1, pg 299)

0.85

Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250)


h = mean roof height

=
=

0.85
14.50 ft
(ASCE 7-10 26.2.1)
(ASCE 7-10 26.2.2)

< 60 ft, [Satisfactory]


< Min (L, B), [Satisfactory]
Design pressures for MWFRS

p = qh [(G Cpf )-(G Cpi )]


where:

p = pressure in appropriate zone. (Eq. 28.4-1, page 298).

pmin =

16

psf (ASCE 7-10 28.4.4)

G Cp f = product of gust effect factor and external pressure coefficient, see table below. (Fig. 28.4-1, page 300 & 301)
G Cp i = product of gust effect factor and internal pressure coefficient.(Tab. 26.11-1, Enclosed Building, page 258)
=
0.18
or
-0.18
a = width of edge strips, Fig 28.4-1, note 9, page 301, MAX[ MIN(0.1B, 0.1L, 0.4h), MIN(0.04B, 0.04L), 3] =
Net Pressures (psf), Basic Load Cases
Roof angle =
15.64
Surface

1
2
3
4
5
6
1E
2E
3E
4E
5E
6E

G Cp f

Net Pressure with

0.49
-0.69
-0.45
-0.39

(+GCp i )
10.68
-29.76
-21.49
-19.48

(-GCp i )
23.00
-17.45
-9.17
-7.16

0.74
-1.07
-0.64
-0.58

19.32
-42.76
-28.17
-25.97

31.64
-30.45
-15.86
-13.65

Roof angle = 0.00


G Cp f

-0.45
-0.69
-0.37
-0.45
0.40
-0.29
-0.48
-1.07
-0.53
-0.48
0.61
-0.43

Net Pressure with

(+GCp i )
-21.55
-29.76
-18.82
-21.55
7.53
-16.08
-22.58
-42.76
-24.29
-22.58
14.71
-20.87

(-GCp i )
-9.24
-17.45
-6.50
-9.24
19.84
-3.76
-10.26
-30.45
-11.97
-10.26
27.03
-8.55

5.00

Net Pressures (psf), Torsional Load Cases


Roof angle = 15.64
Surface

1T
2T
3T
4T
Surface

5T
6T

G Cp f

Net Pressure with

(+GCp i ) (-GCp i )
0.49
2.67
5.75
-0.69
-7.44
-4.36
-0.45
-5.37
-2.29
-0.39
-4.87
-1.79
Roof angle = 0.00
G Cp f

0.40
-0.29

Net Pressure with

(+GCp i ) (-GCp i )
1.88
4.96
-4.02
-0.94

ft

Basic Load Case A (Transverse Direction)


Surface

1
2
3
4
1E
2E
3E
4E

Min. wind
28.4.4

Area
(ft2)

990
2337
2337
990
110
260
260
110
Horiz.
Vert.
Horiz.
Vert.

Basic Load Case B (Longitudinal Direction)

Pressure (k) with

(+GCp i )
10.57
-69.54
-50.20
-19.28
2.13
-11.10
-7.31
-2.86
28.60
-133.04
28.80
-80.00

Surface

(-GCp i )
22.77
-40.77
-21.43
-7.09
3.48
-7.90
-4.12
-1.50
28.60
-71.46
28.80
-80.00

2
3
5
6
2E
3E
5E
6E

Min. wind
28.4.4

Torsional Load Case A (Transverse Direction)


Surface

1
2
3
4
1E
2E
3E
4E
1T
2T

Area
(ft2)

440
1038
1038
440
110
260
260
110
550
1298

Pressure (k) with

(+GCp i )
4.70
-30.91
-22.31
-8.57
2.13
-11.10
-7.31
-2.86
1.47
-9.66

Pressure (k) with

(ft2)

2337
2337
608
608
260
260
117
117
Horiz.
Vert.
Horiz.
Vert.

(+GCp i )
-69.54
-43.96
4.58
-9.78
-11.10
-6.31
1.72
-2.44
18.51
-110.00
11.60
-80.00

(-GCp i )
-40.77
-15.19
12.06
-2.29
-7.90
-3.11
3.16
-1.00
18.51
-51.80
11.60
-80.00

Torsional Load Case B (Longitudinal Direction)

Torsion (ft-k)

-47
-67

-20
-25

339

339

Area

Surface

(-GCp i ) (+GCp i ) (-GCp i )


10.12
106
228
-18.12
-188
-110
-9.52
135
58
-3.15
193
71
3.48
96
157
-7.90
-135
-96
-4.12
89
50
-1.50
129
68
3.16
-37
-79
-5.66
65
38

3T
1298
-6.97
-2.98
4T
550
-2.68
-0.98
Total Horiz. Torsional Load, MT

Area

Pressure (k) with

Torsion (ft-k)

(ft2)

(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )


2
2337
-69.54
-40.77
-47
-27
3
2337
-43.96
-15.19
30
10
5
246
1.85
4.87
17
46
6
246
-3.95
-0.92
37
9
2E
260
-11.10
-7.90
142
101
3E
260
-6.31
-3.11
-81
-40
5E
117
1.72
3.16
39
71
6E
117
-2.44
-1.00
55
22
5T
363
0.68
1.80
-8
-21
6T
363
-1.46
-0.34
-17
-4
Total Horiz. Torsional Load, MT
167.4
167.4

Design pressures for components and cladding

p = qh[ (G Cp) - (G Cpi)]


where:

p = pressure on component. (Eq. 30.4-1, pg 318)


pmin =

16.00

psf (ASCE 7-10 30.2.2)

G Cp = external pressure coefficient.


see table below. (ASCE 7-10 30.4.2)

Effective
Area (ft2)
Comp.

28

Comp. & Cladding


Pressure
( psf )

Note:

Zone 1
GCP
- GCP

0.41

-0.86

Zone 1

GCP

Zone 2
- GCP

GCP

Zone 3
- GCP

0.41

-1.48

0.41

-2.33

Zone 2

Zone 3

Zone 4
GCP
- GCP

0.92

-1.02

Zone 4

Zone 5
GCP
- GCP

0.92

-1.24

Zone 5

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

20.20

-35.42

20.20

-56.67

20.20

-85.93

37.67

-41.09

37.67

-48.65

If the effective area is roof Solar Panel area, the only zone 1, 2 , or 3 apply.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Building with h > 60 ft, Based on ASCE 7-2010
INPUT DATA
Exposure category (B, C or D, ASCE 7-10 26.7.3)
Importance factor (ASCE 7-10 Table 1.5-2)

Building height to roof

Iw
V
Kzt
H

=
=
=
=

Parapet height
Building length
Building width
Natural frequency (ASCE 7-10 26.9)

HP
L
B
n1

=
4
=
300
=
180
= 0.95541

Effective area of mullion

AM =

55

ft
ft
ft
Hz, (1 / T)
ft2

Effective area of panel

AP =

27

ft2

Basic wind speed (ASCE 7-10 26.5.1 or 2012 IBC)


Topographic factor (ASCE 7-10 26.8 & Table 26.8-1)

1.00
144
1
157

for all Category


mph
Flat
ft

DESIGN SUMMARY
Max building horizontal force normal to building length, L, face
Max overturning moment at wind normal to building length, L, face
Max building horizontal force normal to building length, B, face
Max overturning moment at wind normal to building length, B, face
Max building upward force
Max building torsion force

=
=
=
=
=
=

3084.3
464683.0
1641.7
412095.1
3445.2
104096.3

kips, SD level (LRFD level), Typ.


ft - kips
kips
ft - kips
kips
ft - kips

ANALYSIS
Velocity pressures

qz = 0.00256 Kz Kzt Kd V2
where:

qz = velocity pressure at height, z. (Eq. 27.3-1, page 260 & Eq. 30.3-1 page 316)

pmin =

16

psf (ASCE 7-10 27.4.7)

Kz = velocity pressure exposure coefficient evaluated at height, z. (Tab. 27.3-1, page 261)
Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250)
z = height above ground

0.85

z (ft)
Kz

0 - 15

20

25

30

40

50

60

70

80

90

100

120

0.85

0.90

0.94

0.98

1.04

1.09

1.13

1.17

1.21

1.24

1.26

1.31

qz (psf)

38.35

40.61

42.41

44.22

46.93

49.18

50.99

52.79

54.60

55.95

56.85

59.11

z (ft)
Kz

140

160

161

161

161

161

161

161

161

161

1.36

1.39

1.39

1.39

1.39

1.39

1.39

1.39

1.39

1.39

qz (psf)

61.37

62.72

62.81

62.81

62.81

62.81

62.81

62.81

62.81

62.81

0.18

or

Design pressures for MWFRS

p = q G Cp - qh (G Cpi)
where:

p = pressure on surface for rigid building with all h. (Eq. 27.4-1, page 260).
q = qz for windward wall at height z above the ground, see table above.
G Cp i = internal pressure coefficient. (Tab. 26.11-1, Enclosed Building, page 258)

-0.18

qh = qz value at mean roof height, h, for leeward wall, side walls, and roof.
Cp = external pressure coefficient, see right down tables. (Tab. 27.4-1, page 263)
G = gust effect factor (ASCE 7-10 26.9, Page 254)

1 + 1.7 I g 2 Q 2 + g 2 R 2
Iz =
0.17
R
z Q
0.925

1 + 1.7 g v I z

G=

1 + 1.7 g Q I zQ
0.925
, for

1 + 1.7 g v I z

, for n1 < 1.0

= 0.861

n1 1.0

z =

94.2

Q=

0.84

z min =

15

gQ =

3.4

617

c=

0.2

gR =

4.18

Lz =
=

Rh =

0.206

RB =

0.183

RL =

0.036

N1 =

3.65

Rn =

0.062

R=

0.160

h=

157

gv =

3.4

Vz =

161.3

Fig. 27.4-1 fo < 10o, page 263


Roof

h/B
0.89
0.89
0.89
0.89
h/L

Distance
80.5
161
180
180
Distance

Cp
-1.01
-0.74
-0.66

To B Face

0.54

80.5

-0.91

To B Face

0.54
0.54
0.54

161
300
300

-0.89
-0.51

To L Face
To L Face
To L Face
To L Face

Roof

q G Cp Figure for Gable, Hip Roof, page 48


Fig. 27.4-1, page 263
Wall
Windward Wall
Leeward Wall
Leeward Wall
Side Wall

Direction
All
To L Dir
To B Dir
All

L/B
All
0.60
1.67
All

Cp
0.80
-0.50
-0.37
-0.70

To B Face
To B Face

Cp

0.05

(cont'd)
Hence, MWFRS Net Pressures are given by following tables (ASCE 7-10 27.4.1, Page 260)
P (psf) with

Windward Wall

Surface

z (ft)

GCPi

- GCPi

Surface

z (ft)

0 - 15
20
25
30
40

15.10
16.66
17.90
19.14
21.01

37.71
39.27
40.51
41.75
43.62

Side Wall

All

Surface

z (ft)

50
60
70
80
90

22.56
23.80
25.05
26.29
27.22

45.17
46.41
47.66
48.90
49.83

Leeward

All

100
120
140
160
161

27.84
29.39
30.95
31.88
31.94

50.45
52.01
53.56
54.49
54.55

Normal to L Face

Normal to L Face

Surface

Roof

Dist. (ft)

0 - 80.5
161
180

P (psf) with
GCPi
- GCPi
-49.15

-26.54

P (psf) with
GCPi
- GCPi

Normal to B Face

Surface

z (ft)

-15.72

Leeward

All

P (psf) with
GCPi
- GCPi

Surface

-38.34

-65.93
-51.43
-46.87

-43.32
-28.82
-24.25

Normal to B Face

Roof

Dist. (ft)

0 - 80.5
161
300

P (psf) with
GCPi
- GCPi
-31.13

-8.52

P (psf) with
GCPi
- GCPi
-60.51
-59.17
-39.13

-37.90
-36.56
-16.52

Figure 27.4-8, page 271


Base Forces

Normal to L Face
Case 1
Case 2

Normal to B Face
Case 1
Case 2

Wind with Angle


Case 3
Case 4

ASCE-7

VBase

(kips)

3084

2313

1642

1231

3545

1967

MBase

(ft - kips)

464683

348512

412095

309071

657584

349674

Fig. 27.4-8

MT

(ft - kips)

104096

33245

103097

Page 271

2491

1868

2103

1577

3445

1835

(kips)

773

773

464

464

927

901

Min. wind

FUp,min (kips)

864

864

864

864

864

864

27.4.7

FUpward (kips)
Vmin

Design pressures for components and cladding

p = q (G Cp) - qi (G Cpi)
where:

p = pressure on component for building with h > 60 ft. (Eq. 30.6-1, page 320)
pmin =

16.00

psf (ASCE 7-10 30.2.2)

q = qz for windward wall at height z above the ground, see table above.
qh = qz value at mean roof height, h, for leeward wall, side walls, and roof.
G Cp i = internal pressure coefficient. (Tab. 26.11-1, pg 258) =
0.18
or
-0.18
a = Zone width = MAX[ MIN(0.1B, 0.1L), 3] =
18.0 ft, (Fig 30.6-1 note 8, pg 348)
G Cp = external pressure coefficient. (Fig 30.6-1 note 8, pg 348)
Wall
Comp.

Actual Effective
2
Area ( ft )

Mullion
Panel

z (ft)

0 - 15
20
25
30
40
50
60
70
80
90
100
120
140
160
161

55
27

Zone 4
GCP
- GCP

GCP

- GCP

0.81
0.87

0.81
0.87

-1.55
-1.73

-0.84
-0.88

Zone 5

Mullion Pressure (psf)


Zone 4
Zone 5

Panel Pressure (psf)


Zone 4
Zone 5

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

37.81
40.03
41.81
43.59
46.26
48.48
50.26
52.04
53.82
55.15
56.04
58.27
60.49
61.82
61.91

-63.89
-63.89
-63.89
-63.89
-63.89
-63.89
-63.89
-63.89
-63.89
-63.89
-63.89
-63.89
-63.89
-63.89
-63.89

37.81
42.72
44.62
46.52
49.37
51.74
53.64
55.54
57.44
58.86
59.81
62.18
64.56
65.98
66.08

-108.57
-108.57
-108.57
-108.57
-108.57
-108.57
-108.57
-108.57
-108.57
-108.57
-108.57
-108.57
-108.57
-108.57
-108.57

40.35
42.72
44.62
46.52
49.37
51.74
53.64
55.54
57.44
58.86
59.81
62.18
64.56
65.98
66.08

-66.66
-66.66
-66.66
-66.66
-66.66
-66.66
-66.66
-66.66
-66.66
-66.66
-66.66
-66.66
-66.66
-66.66
-66.66

40.35
42.72
44.62
46.52
49.37
51.74
53.64
55.54
57.44
58.86
59.81
62.18
64.56
65.98
66.08

-119.68
-119.68
-119.68
-119.68
-119.68
-119.68
-119.68
-119.68
-119.68
-119.68
-119.68
-119.68
-119.68
-119.68
-119.68

cont'd

Components and Cladding

Roof

Components and Cladding

Roof

Effective
Area ( ft2 )

Zone 1

Zone 2

Zone 3

- GCP

- GCP

- GCP

-1.40

-2.30

-3.20

10

-1.40

-2.30

-3.20

59

-1.17

-1.98

-2.79

108

-1.10

-1.87

-2.65

157

-1.05

-1.81

-2.57

206

-1.01

-1.76

-2.50

255

-0.99

-1.72

-2.45

304

-0.96

-1.69

-2.41

353

-0.94

-1.66

-2.38

402

-0.93

-1.64

-2.35

451

-0.91

-1.62

-2.32

500

-0.90

-1.60

-2.30

38016

-0.90

-1.60

-2.30

38016

4104

972

Net Pressure (psf)

Effective
Area ( ft2 )

Zone 1

Zone 2

Zone 3

-99.24

-155.77

-212.30

10

-99.24

-155.77

-212.30

59

-84.99

-135.82

-186.65

108

-80.14

-129.02

-177.91

157

-77.13

-124.82

-172.50

206

-74.95

-121.77

-168.58

255

-73.24

-119.37

-165.50

304

-71.83

-117.39

-162.96

353

-70.63

-115.71

-160.80

402

-69.59

-114.25

-158.92

451

-68.66

-112.96

-157.26

500

-67.83

-111.80

-155.77

38016

-67.83

-111.80

-155.77

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Enclosed Building, Based on DSA IR 16-7 (SEAOC)


INPUT DATA
Exposure category (B, C or D)
Importance factor, IR 16-7 3.1, (0.87, 1.0 or 1.15)
Basic wind speed (IBC Tab 1609.3.1V3S)

I =
V =

C
1.00
85

Topographic factor (IR 16-7 3.3.2)

Kzt =

Flat

Building height to eave

he =

11

ft

Building height to ridge


Building length
Building width
Effective area of components

hr
L
B
A

=
=
=
=

18
100
50
28

ft
ft
ft
ft2

Category II
mph

18

100

DESIGN SUMMARY
Max horizontal force normal to building length, L, face
Max overturning moment at wind normal to building length, L, face
Max horizontal force normal to building length, B, face
Max overturning moment at wind normal to building length, B, face
Max total horizontal torsional load
Max total upward force

=
=
=
=
=
=

18.00
267.64
10.71
79.19
250.01
58.80

kips
ft - kips
kips
ft - kips
ft-kips
kips

ANALYSIS
Velocity pressure (IR 16-7 Table 1)

qs =

18.50

psf

Design pressures for MWFRS (IR 16-7 Equation 1)

Pnet = qs Kz Cnet [ I Kzt]


where:

Pnet, min =

10

psf on projected area (IR 16-7 3.2)

Kz = velocity pressure exposure coefficient evaluated at height, h, (IR 16-7 3.3.2)


=
h = mean roof height
=
14.50 ft
< 75 ft, [Satisfactory] (IR 16-7 2.3)
(SEAOC updated limitation to 75 ft)
0.10
(Roof angle =

Cnet (IR 16-7 Table 2)


Cnet, Area, & Pnet

Windward
Wall

Leeward
Wall
Side
Wall
Windward
Roof

Leeward
Roof

Normal to L Face
Case 1
Case 2

Normal to B Face
Case 1
Case 2

Normal to L Face
Case 3
Case 4

o
15.64 )

Normal to B Face
Case 3
Case 4

Cnet

0.43

0.43

0.43

0.43

0.43

0.43

0.43

0.43

Area (ft2)

1100

1100

725

725

1100

1100

725

725

Pnet (psf)

Cnet

-0.51

-0.51

-0.51

-0.51

-0.51

-0.51

-0.51

-0.51

Area (ft2)

1100

1100

725

725

1100

1100

725

725

Pnet (psf)

-8

-8

-8

-8

-8

-8

-8

-8

Cnet

-0.66

-0.66

-0.66

-0.66

-0.66

-0.66

-0.66

-0.66

Area (ft2)

725

725

1100

1100

725

725

1100

1100

Pnet (psf)

-10

-10

-10

-10

-10

-10

-10

-10

Cnet

-0.84

-0.12

Area (ft2)

2596

2596

Pnet (psf)

-13

-2

Cnet

-0.66

-0.66

Area (ft2)

2596

2596

Pnet (psf)

-10

-10

0.85

(SEAOC updated more 45o by wall)

__
Page 436 of 533
524

cont'd
Base Forces

Normal to L Face
Case 1
Case 2

Normal to B Face
Case 1
Case 2

Normal to L Face
Case 3
Case 4

Normal to B Face
Case 3
Case 4

Minimum
to L
to B

VBase

(kips)

14.32

16.67

10.71

8.04

12.19

9.15

8.04

6.03

18.00

7.25

MBase

(ft - kips)

234.34

-267.64

79.19

59.39

67.06

50.34

59.39

44.58

162.00

53.58

MT

(ft - kips)

0.00

250.01

0.00

60.27

0.00

182.52

0.00

182.52

-58.80

-22.93

FUpward

(kips)

Design pressures for components and cladding

Pnet = qs Kz Cnet [ I Kzt]


where:

Pnet, min =
10
psf (IR 16-7 3.2)
a = width of edge strips, ASCE 7 Fig 6-10, note 9, page 54, MAX[ MIN(0.1B, 0.4h), 0.04B,3] =

5.00

ft

Cnet (IR 16-7 Table 2)


Cnet
Roof
Overhang

Effective
Area (ft2)

28

Pressure (psf)
Roof
Overhang

Zone 1

Zone 2

Zone 3

Zone 4

Zone 5

Cnet

- Cnet

Cnet

- Cnet

Cnet

- Cnet

Cnet

- Cnet

Cnet

- Cnet

0.55

-0.98
-1.43

0.55

-1.58
-1.87

0.55

-2.39
-2.95

0.99

-1.08

0.99

-1.32

Zone 1

Zone 2

Zone 3

Zone 4

Zone 5

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

10.00

-15.47
-22.51

10.00

-24.81
-29.40

10.00

-37.64
-46.32

15.58

-16.99

15.58

-20.77

__
Page 437 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Analysis Based on IBC 09 (Equivalent Lateral-Force Procedure, ASCE 7-05 12.8 & Supplement 2)

INPUT DATA

DESIGN SUMMARY

Typical floor height


Typical floor weight
Number of floors
Importance factor (ASCE 11.5.1)
Building location
Site class (A, B, C, D, E, F)
The coefficient (ASCE Tab 12.8-2)
The coefficient(ASCE Tab. 12.2.1)

h=
9
wx = 800
n=
40
I = 1.25
Zip Code 92868
D
Ct = 0.02
R=

ft
k
(IBC Tab.1604.5)
(If no soil report, use D)

Total base shear


V
=
0.07 W, (SD) =
=
0.05 W, (ASD) =
Seismic design category
=
Latitude:
33.784
Longitude:
-117.874
SS = 137.545 %g , Sms = 1.375 g , Fa =
S1 = 49.629 %g , Sm1 =

5.5

SDS = 0.917 g ,
hn

360.0 ft

k =

32,000 k

wxhk =

1.58

, (ASCE 12.8.3, pg 130)

0.746

1.000

Fv =

1.504

SD1 = 0.498 g
x =

0.75
x

137,376,298

g,

2,189 k, (SD)
1,564 k, (ASD)
D

Ta = Ct (hn) =

, (ASCE Tab 12.8-2)

1.65

Sec, (ASCE 12.8.2.1)

VERTICAL DISTRIBUTION OF LATERAL FORCES


Level

Level

No.

Name

40

Roof

Floor to floor
Height
ft

Height

Weight

hx
ft
360.0

wx
k
800

wxhxk

Cvx

Lateral force @ each level

8,570,835

0.062

Fx
k
136.6

351.0

800

8,235,486

0.060

131.2

9.00
39

40th
39th

342.0

38th

800

7,905,058

0.058

126.0

333.0

37th

800

7,579,605

0.055

120.8

324.0

36th

800

7,259,185

0.053

115.7

315.0

35th

800

6,943,854

0.051

110.6

306.0

34th

800

6,633,675

0.048

105.7

297.0

33th

800

6,328,712

0.046

100.8

288.0

32th

800

6,029,030

0.044

96.1

279.0

31th

800

5,734,699

0.042

91.4

270.0

30th

800

5,445,792

0.040

86.8

261.0

29th

800

5,162,383

0.038

82.3

252.0

28th

800

4,884,554

0.036

77.8

243.0

27th

800

4,612,387

0.034

73.5

234.0

26th

800

4,345,970

0.032

69.3

225.0

25th

800

4,085,396

0.030

65.1

216.0

24th

800

3,830,763

0.028

61.0

207.0

23th

21

22th

800

3,582,175

0.026

57.1

20

21th

180.0
9.00

19

20th

171.0
9.00

800

3,339,741

0.024

53.2

__

189.0
9.00

630.2

4,000

183

17,486

740.9

4,800

183

24,154

846.6

5,600

183

31,773

947.4

6,400

183

40,299

1,043.5

7,200

183

49,691

1,134.9

8,000

183

59,904

1,221.6

8,800

183

70,899

1,303.9

9,600

183

82,634

1,381.7 10,400

183

95,069

1,455.2 11,200

183

108,166

1,524.5 12,000

183

121,887

1,589.6 12,800

183

136,193

1,650.6 13,600

183

151,048

1,707.7 14,400

183

166,417

1,760.9 15,200

183

182,266

1,810.4 16,000

183

198,559

1,856.2 16,800

183

215,264

1,898.4 17,600

183

1,707.7
198.0

9.00

11,814

1,650.6

9.00
22

183

1,589.6

9.00
23

3,200

1,524.5

9.00
24

514.5

1,455.2

9.00
25

7,183

1,381.7

9.00
26

183

1,303.9

9.00
27

2,400

1,221.6

9.00
28

393.8

1,134.9

9.00
29

3,639

1,043.5

9.00
30

183

947.4

9.00
31

1,600

846.6

9.00
32

267.8

740.9

9.00
33

1,229

630.2

9.00
34

Fpx
k
183

514.5

9.00
35

W i
k
800

393.8

9.00
36

Fi
k
136.6

267.8

9.00
37

Diaphragm force

O. M.
k-ft

136.6

9.00
38

Vx
k

800

800

800

3,103,579

2,873,813

2,650,577

0.023

0.021

0.019

Page 438 of 533


524

1,760.9

49.5

1,810.4

45.8

1,856.2

42.2

1,898.4

Level

Level

No.

Name

18

19th

Floor to floor
Height
ft

Height

Weight

hx
ft

wx
k

wxhxk

Cvx

Lateral force @ each level


Fx
k

162.0

800

2,434,015

0.018

38.8

9.00
17

18th

153.0

17th

800

2,224,281

0.016

35.4

144.0

16th

800

2,021,542

0.015

32.2

135.0

15th

800

1,825,982

0.013

29.1

126.0

14th

800

1,637,798

0.012

26.1

117.0

13th

800

1,457,210

0.011

23.2

108.0

12th

800

1,284,460

0.009

20.5

99.0

11th

800

1,119,820

0.008

17.8

90.0

10th

800

963,594

0.007

15.4

81.0

9th

800

816,129

0.006

13.0

72.0

8th

800

677,826

0.005

10.8

63.0

7th

800

549,156

0.004

8.8

54.0

6th

800

430,681

0.003

6.9

45.0

5th

800

323,094

0.002

5.1

36.0

4th

800

227,276

0.002

3.6

27.0

3rd

800

144,408

0.001

2.3

18.0

2nd

800

76,206

0.001

1.2

2,060.0 21,600

183

322,427

2,083.2 22,400

183

341,176

2,103.7 23,200

183

360,109

2,121.6 24,000

183

379,203

2,136.9 24,800

183

398,435

2,149.9 25,600

183

417,784

2,160.7 26,400

183

437,231

2,169.5 27,200

183

456,756

2,176.3 28,000

183

476,343

2,181.5 28,800

183

495,976

2,185.1 29,600

183

515,642

2,187.4 30,400

183

535,328

2,188.6 31,200

183

555,026

2,189.0 32,000

183

2,188.6
9.0

800

25,552

0.000

0.4

9.00
Ground

303,886

2,187.4

9.00
1

183

2,185.1

9.00
2

2,033.9 20,800

2,181.5

9.00
3

285,581

2,176.3

9.00
4

183

2,169.5

9.00
5

2,004.8 20,000

2,160.7

9.00
6

267,538

2,149.9

9.00
7

183

2,136.9

9.00
8

1,972.6 19,200

2,121.6

9.00
9

249,784

2,103.7

9.00
10

183

2,083.2

9.00
11

1,937.2 18,400

2,060.0

9.00
12

232,350

2,033.9

9.00
13

Fpx
k
(cont'd)

2,004.8

9.00
14

W i
k

1,972.6

9.00
15

O. M.
k-ft

Diaphragm force
Fi
k

1,937.2

9.00
16

Vx
k

2,189.0
0.0

574,727

__
Page 439 of 533
524

PROJECT :

PAGE :

CLIENT :

DESIGN BY :

JOB NO. :

DATE :

REVIEW BY :

Four Story Seismic Analysis Based on CBC 2010 Chapter A


Determine Base Shear (Derived from ASCE 7-05 Sec. 12.8, Supplement 2, & CBC 2010 Sec. 1614A.1.7)
V = MAX{ MIN [ SD1I / (RT) , SDS I / R ] , MAX(0.044SDSI , 0.01) , 0.5S1 I / R } W

= MAX{ MIN[ 0.15W , 0.18W ] , 0.06W , 0.00W }


=
0.15
W, (SD)
=
0.11
W, (ASD) =
1454.89 kips
Where

(for S1

0.6 g only)

SDS =

0.96

(ASCE 7-05 Sec 11.4.4)

SD1 =

0.54

(ASCE 7-05 Sec 11.4.4)

S1 =

0.55

(ASCE 7-05 Sec 11.4.1)

R=

(ASCE 7-05 Tab 12.2-1)

I=

1.5

Ct =

0.028

(0.028 for steel MRF, 0.016 for concrete MRF, & 0.03 steel EBF)

hn =

52.0

ft

0.8

(ASCE 7-05 Tab 12.8-2)

x=
x

T = Ct (hn) =

(IBC 09 Tab 1604A.5 & ASCE 7-05 Tab 11.5-1)

0.661

sec, (ASCE 7-05 Sec 12.8.2.1)

Calculate Vertical Distribution of Forces & Allowable Elastic Drift (ASCE 7-05, Sec 12.8.3 & 12.8.6)
Level
Roof
4TH
3RD
2ND

Where

Wx

hx

hx

120
3500
4050
5620
13290.0

52
40
28
16

71.4
53.8
36.6
20.0

Wxhx
8571
188278
148199
112349
457396

Fx , ASD (12.8-11)
27.3
598.9
471.4
357.4
1454.9

xe,allowable, ASD
0.3
0.3
0.3
0.4

( 0.23 Wx )
( 0.17 Wx )
( 0.12 Wx )
( 0.06 Wx )

xe,allowable, ASD = a I / (1.4 Cd), (ASCE 7-05 Sec 12.8.6)

k = 1

for T <= 0.5

k = 0.5 T + 0.75

for T @ (0.5 , 2.5)

Cd =

5.5

,(ASCE 7-05 Tab 12.2-1)

k = 2

for T >= 2.5

a =

0.01

hsx, (ASCE 7-05 Tab 12.12-1,


& Sec 12.12)

Calculate Diaphragm Forces (ASCE 7-05, Sec 12.10.1.1)


Level
Roof
4TH
3RD
2ND

Where

Wx

Wx

Fx

120.0
3500.0
4050.0
5620.0
13290.0

120.0
3620.0
7670.0
13290.0

27.3
598.9
471.4
357.4
1454.9

Fx
27.3
626.1
1097.5
1454.9

__

Fmin = 0.2 SDS I W x / 1.5 , ASD

Fmax = 0.4 SDS I W x / 1.5 , ASD

Page 440 of 533


524

Fpx , ASD, (12.10-1)


27.3
( 0.23 Wx )
672.0
( 0.19 Wx )
777.6
( 0.19 Wx )
1079.0
( 0.19 Wx )

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Method to Calculate Redundancy Factor, , Based on IBC 2009


There are big updated to calculate redundancy factor from new IBC 2009. (ASCE 7-05 Sec 12.3.4)
= 1.3 ,

only for Seismic Design Categories D through F, and an individual element removed will be causing the remaining
structural to suffer a reduction of Story Strength of more than 35% or creating an extreme torsional irregularity.

= 1.0 ,

all other cases.

Note:

To verify Redundancy Factor 1.0, the relative Rigidity of each frame at calculation level have to be known, since the Code
Redundancy Provision Committee envisioned Story Strength as Rigidity, and SEAOC Seismology Committee endorsed
this interpretation (SEAOC Seismic Design Manual -1, page 72).

4231.4(3231.4+153.8)
= 8.4% 33%
4231.4

= 1.0

__
Page 441 of 533
524

PROJECT :

PAGE :

CLIENT :

DESIGN BY :

JOB NO. :

DATE :

REVIEW BY :

Response Spectra Analysis Based on IBC 09


INPUT DATA

ANALYSIS

SEISMIC DESIGN PARAMETER

SDS =

0.96

(ASCE 7-05 11.4.4)

Station

T (s)

SEISMIC DESIGN PARAMETER

SD1 =

0.545

(ASCE 7-05 11.4.4)

0.00

0.38

0.32

LONG-PERIOD TRANSITION PERIOD

TL =

(ASCE 7-05 11.4.5)

0.10

0.89

0.67

0.13

0.96

0.65

0.17

0.96

0.74

0.18

0.96

0.87

0.20

0.96

0.72

0.25

0.96

0.86

0.33

0.96

0.77

0.43

0.96

0.80

0.50

0.96

0.92

10

0.67

0.82

0.62

11

1.00

0.55

0.45

12

1.25

0.44

0.24

13

1.50

0.36

0.19

14

1.75

0.31

0.15

15

2.00

0.27

0.14

16

2.25

0.24

0.17

17

2.50

0.22

0.18

18
19

2.75
3.00

0.20
0.18

0.16
0.12

20

3.25

0.17

0.11

21

3.50

0.16

0.10

22

3.75

0.15

0.08

23

4.00

0.14

0.06

RESPONSE SPECTRA
1.20
1.00

Sa (g)

0.80
0.60
0.40
0.20
0.00
0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

Period T, Seconds

Sa(g) (IBC/CBC) A/g (El Centro)

STATIC ANALYSIS PERIOD (ASCE 7-05 12.8.2)


x

APPROXIMATE FOUNDATIONAL PERIOD

Ta = Ct (hn) =

0.799

sec, (ASCE 7-05 Sec 12.8.2.1)

Tb =

1.095

sec, (may from RISA, ETABS, RAM)

SUBSTANTIATED ANALYSIS PERIOD

T = Max[ Ta , Min( Tb , CuTa )] =


where Cu =

1.400

1.095

sec.

, (ASCE 7-05 Tab. 12.8-1)

SCALE FACTOR
BASE SHEAR BY ELASTIC DYNAMIC ANALYSIS (ASCE 7-05 12.9)
BASE SHEAR BY STATIC ANALYSIS (ASCE 7-05 12.8)
RESPONSE MODIFICATION COEFFICIENT (ASCE 7 Tab 12.2-1)
IMPORTANCE FACTOR
DSA/OSHPD PROJECT (CBC 2010 Chapter A) ?

VDX =

3000

kips

VS =

735.09

kips

8
1.5

SFX = VX / VD

= 0.245

== >

Yes

SFY = VY / VD

= 0.210

624.83

kips, (ASCE 7-05 12.9.2 & 12.9.4)

735.09

kips, (ASCE 7-05 12.9.2 & CBC 10 1614A.1.9)

VY = Max( 0.85 VS , VDY I / R ) =

656.25

kips, (ASCE 7-05 12.9.2 & 12.9.4)

VY = Max( 1.0 VS , VDY I / R ) =

735.09

kips, (ASCE 7-05 12.9.2 & CBC 10 1614A.1.9)

http://www.engineering-international.com/NonlinearGuide.pdf

kips

I=

VX = Max( 1.0 VS , VDX I / R ) =

See following link for more information.

3500

R=

VX = Max( 0.85 VS , VDX I / R ) =

Notes:

VDY =

PROJECT :

PAGE :

CLIENT :

DESIGN BY :

JOB NO. :

DATE :

REVIEW BY :

Three Story Seismic Analysis Based on IBC 09 / CBC 10


Determine Base Shear (Derived from ASCE 7-05 Sec. 12.8 & Supplement 2)
V = MAX{ MIN [ SD1I / (RT) , SDS I / R ] , MAX(0.044SDSI , 0.01) , 0.5S1 I / R } W

= MAX{ MIN[ 0.29W , 0.15W ] , 0.04W , 0.00W }


=
0.15 W, (SD)
=
0.11 W, (ASD) = 1067.60 kips
Where

(for S1

SDS =

0.96

(ASCE 7-05 Sec 11.4.4)

SD1 =

0.55

(ASCE 7-05 Sec 11.4.4)

S1 =

0.54

(ASCE 7-05 Sec 11.4.1)

R=

6.5

(ASCE 7-05 Tab 12.2-1)

I=

Ct =

0.02

(ASCE 7-05 Tab 12.8-2)

hn =

36.0

ft

0.75

(ASCE 7-05 Tab 12.8-2)

x=

T = Ct (hn) =

0.6 g only)

(IBC 09 Tab 1604.5 & ASCE 7-05 Tab 11.5-1)

0.294

sec, (ASCE 7-05 Sec 12.8.2.1)

Calculate Vertical Distribution of Forces & Allowable Elastic Drift (ASCE 7-05, Sec 12.8.3 & 12.8.6)
k

Wx

hx

hx

Roof

120

36

36.0

4320

26.0

( 0.22 Wx )

0.5

3RD

4400

24

24.0

105600

636.5

( 0.14 Wx )

0.5

2ND

5600

12

12.0

67200

405.1

( 0.07 Wx )

0.5

177120

1067.6

10120.0
Where

Wxhx

Fx , ASD (12.8-11)

xe,allowable, ASD

Level

xe,allowable, ASD = a I / (1.4 Cd), (ASCE 7-05 Sec 12.8.6)

k = 1

for T <= 0.5

k = 0.5 T + 0.75

for T @ (0.5 , 2.5)

Cd =

k = 2

for T >= 2.5

a =

0.02

,(ASCE 7-05 Tab 12.2-1)


hsx, (ASCE 7-05 Tab 12.12-1)

Calculate Diaphragm Forces (ASCE 7-05, Sec 12.10.1.1)


Level

Wx

Wx

Fx

Fx

Fpx , ASD, (12.10-1)

Roof

120.0

120.0

26.0

26.0

26.0

( 0.22 Wx )

3RD

4400.0

4520.0

636.5

662.6

645.0

( 0.15 Wx )

2ND

5600.0
10120.0

10120.0

716.8

( 0.13 Wx )

Where

__
405.1
1067.6

1067.6

Fmin = 0.2 SDS I W x / 1.5 , ASD

Fmax = 0.4 SDS I W x / 1.5 , ASD

Page 443 of 533


524

PROJECT :

PAGE :

CLIENT :

DESIGN BY :

JOB NO. :

DATE :

REVIEW BY :

Two Story Seismic Analysis Based on IBC 09 / CBC 10


Determine Base Shear (Derived from ASCE 7-05 Sec. 12.8 & Supplement 2)
V = MAX{ MIN [ SD1I / (RT) , SDS I / R ] , MAX(0.044SDSI , 0.01) , 0.5S1 I / R } W

= MAX{ MIN[ 0.39W , 0.15W ] , 0.04W , 0.00W }


=
0.15 W, (SD)
=
0.11 W, (ASD) =
603.43 kips
Where

(for S1

SDS =

0.96

(ASCE 7-05 Sec 11.4.4)

SD1 =

0.55

(ASCE 7-05 Sec 11.4.4)

S1 =

0.54

(ASCE 7-05 Sec 11.4.1)

R=

6.5

(ASCE 7-05 Tab 12.2-1)

I=

Ct =

0.02

(ASCE 7-05 Tab 12.8-2)

hn =

24.0

ft

0.75

(ASCE 7-05 Tab 12.8-2)

x=

T = Ct (hn) =

0.6 g only)

(IBC 09 Tab 1604.5 & ASCE 7-05 Tab 11.5-1)

0.217

sec, (ASCE 7-05 Sec 12.8.2.1)

Calculate Vertical Distribution of Forces & Allowable Elastic Drift (ASCE 7-05, Sec 12.8.3 & 12.8.6)
k

Wx

hx

hx

Roof

120

24

24.0

2880

24.8

( 0.21 Wx )

0.5

2ND

5600

12

12.0

67200

578.6

( 0.10 Wx )

0.5

70080

603.4

5720.0
Where

Wxhx

Fx , ASD (12.8-11)

xe,allowable, ASD

Level

xe,allowable, ASD = a I / (1.4 Cd), (ASCE 7-05 Sec 12.8.6)

k = 1

for T <= 0.5

k = 0.5 T + 0.75

for T @ (0.5 , 2.5)

Cd =

k = 2

for T >= 2.5

a =

0.02

,(ASCE 7-05 Tab 12.2-1)


hsx, (ASCE 7-05 Tab 12.12-1)

Calculate Diaphragm Forces (ASCE 7-05, Sec 12.10.1.1)


Level

Wx

Wx

Fx

Fx

Fpx , ASD, (12.10-1)

Roof

120.0

120.0

24.8

24.8

24.8

( 0.21 Wx )

2ND

5600.0
5720.0

5720.0

578.6
603.4

603.4

716.8

( 0.13 Wx )

Where

__

Fmin = 0.2 SDS I W x / 1.5 , ASD

Fmax = 0.4 SDS I W x / 1.5 , ASD

Page 444 of 533


524

PROJECT :

PAGE :

CLIENT :

DESIGN BY :

JOB NO. :

DATE :

REVIEW BY :

One Story Seismic Analysis Based on IBC 09 / CBC 10


Determine Base Shear (Derived from ASCE 7-05 Sec. 12.8 & Supplement 2)
V = MAX{ MIN [ SD1I / (RT) , SDS I / R ] , MAX(0.044SDSI , 0.01) , 0.5S1 I / R } W

= MAX{ MIN[ 0.58W , 0.15W ] , 0.04W , 0.00W }


=
0.15 W, (SD)
=
0.11 W, (ASD) =
12.66 kips
Where

(for S1

SDS =

0.96

(ASCE 7-05 Sec 11.4.4)

SD1 =

0.55

(ASCE 7-05 Sec 11.4.4)

S1 =

0.54

(ASCE 7-05 Sec 11.4.1)

R=

6.5

(ASCE 7-05 Tab 12.2-1)

I=

Ct =

0.02

(ASCE 7-05 Tab 12.8-2)

hn =

14.0

ft

0.75

(ASCE 7-05 Tab 12.8-2)

x=

T = Ct (hn) =

0.6 g only)

(IBC 09 Tab 1604.5 & ASCE 7-05 Tab 11.5-1)

0.145

sec, (ASCE 7-05 Sec 12.8.2.1)

Calculate Vertical Distribution of Forces & Allowable Elastic Drift (ASCE 7-05, Sec 12.8.3 & 12.8.6)
Level
Roof

Where

Wx

hx

hx

120
120.0

14

14.0

Wxhx
1680
1680

Fx , ASD (12.8-11)
12.7
12.7

( 0.11 Wx )

xe,allowable, ASD
0.6

xe,allowable, ASD = a I / (1.4 Cd), (ASCE 7-05 Sec 12.8.6)

k = 1

for T <= 0.5

k = 0.5 T + 0.75

for T @ (0.5 , 2.5)

Cd =

k = 2

for T >= 2.5

a =

0.02

,(ASCE 7-05 Tab 12.2-1)


hsx, (ASCE 7-05 Tab 12.12-1)

Calculate Diaphragm Forces (ASCE 7-05, Sec 12.10.1.1)


Level
Roof

Where

Wx

Wx

Fx

120.0
120.0

120.0

12.7
12.7

Fx
12.7

Fmin = 0.2 SDS I W x / 1.5 , ASD


Fmax = 0.4 SDS I W x / 1.5 , ASD

__
Page 445 of 533
524

Fpx , ASD, (12.10-1)


15.4
( 0.13 Wx )

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Lateral Force for One-Story Wall Based on 2009 IBC


INPUT DATA
WALL THICKNESS
t
PARAPET HEIGHT
hp
WALL HEIGHT
h
TOTAL WALL DENSITY

SEISMIC PARAMETER
SDS
SEISMIC DESIGN CATEGORY SDC
DIAPHRAGM FLEXIBLE ? (0=no, 1=yes)
SEISMIC IMPORTANCE FACTOR
I
WIND IMPORTANCE FACTOR
I
BASIC WIND SPEED
V
EXPOSURE CATEGORY (B, C, D)
TOPOGRAPHIC FACTOR
KZt

=
=
=
=
=
=

8
4
14
150
0.54
C
1
1
1
90
C
1

=
=
=
=
=

in
ft
ft
pcf
(ASCE 7-05 Sec 11.4.4)
Yes
(ASCE 7-05 Tab 11.5-1)
(ASCE 7-05 Tab 6-1)

mph
Flat, (ASCE 6.5.7.2)

DESIGN SUMMARY
Out-of-plane force for wall design
w1
=
22.5 psf (Wind governs)
Out-of-plane force for parapet design
w2
=
61.7 psf (Wind governs)
Out-of-plane force for anchorage design
Fanch
=
440 plf (Horizontal direction)
(The governing seismic forces have been reduced by 0.7 for ASD)

WIND ANALYSIS
Out-of-plane wind force for wall design (ASCE 7-05, Eq.6-22)

( GC P ) ( GC Pi )

w1, wind = q h

= ( 0.00256 K h K Zt K dV 2I )

=
0.86
,
Kd
=
0.85
Where :
Kh
(mean roof h =
16 ft, changeable)
(ASCE Tab. 6-4)
(ASCE Tab. 6-3)
Out-of-plane wind force for parapet design (ASCE 7-05, Eq.6-24)

( GC P ) ( GC Pi )

w 2, wind = q p
Where :

=
0.88
Kp
(ASCE Tab. 6-3)

( GC P ) ( GC Pi )

GCp
=
-1.30 ,
(corner ? Yes , TA = 18.67
(ASCE Fig. 6-11A)

Kd
=
0.85
(ASCE Tab. 6-4)

GCp

=
-1.40 ,
=
1.00
2
(TA = 5.333 ft )
(wall, ASCE Fig. 6-11A)

GCpi
=
0.18
(ASCE Fig. 6-5)

ft2 )

= ( 0.00256 K h K Zt K dV 2 I w ) ( G C P ) ( G C Pi )

22.5 psf

61.7 psf, (ASCE 7-05,6.5.12.4.4)

GCp
=
-2.80
(roof, ASCE Fig. 6-11B)

GCpi
=
0.18
(roof, ASCE Fig. 6-5)

Out-of-plane wind force for anchorage design

F anch ,wind =

h
hp
w1,wind + h p 1 +
w 2,wind
2
2h

440 plf (Horizontal)

SEISMIC ANALYSIS
Out-of-plane seismic force for wall design (ASCE 7-05, Sec.12.11.1)

w1, seismic = MAX ( 0.4 I S DSW p , 0.1W p )


Where :

Wp

100.0 psf ,

0.22 Wp =

21.6 psf

1.0

(IBC Tab 1604.5 & ASCE Tab 11.5-1)


Out-of-plane seismic force for parapet design (ASCE 7-05, Sec. 13.3.1)

w 2, seismic = MAX 0.3S DS I pW p , MIN


Where :

ap

2.5

Ip

(ASCE Tab. 13.5-1)

1.2a p S DS I pW p

Rp
1.0

(ASCE Sec. 13.1.3)

, 1.6 S DS I pW p

Rp

0.65 Wp =

64.8

psf

2.5

(ASCE Tab. 13.5-1)

Out-of-plane seismic force for anchorage design


For masonry or concrete under seismic design category A & B, both flexible & rigid diaphragm (ASCE 7-05 Sec. 12.11.2)

F anch , seismic = MAX 0.4 S DS I W

( h+h p )
p

( h+h p )

2h

, 0.1W

2h

, 400 S DS I , F min =

2.80 Wp =
280 plf (Horizontal)
(Not applicable)

Where :

Fmin

280

plf

(ASCE Sec. 12.11.2 & 11.7.3)


For seismic design category C and above, flexible diaphragm (ASCE 7-05 Sec. 12.11.2.1)

F anch , seismic = MAX 0.8S DS I W p

( h+h p )
2h

, 0.1W p

( h+h p )
2h

, 400 S DS I , F min =

5.00 Wp =
500 plf (Horizontal)
(Applicable)

For seismic design category C and above, rigid diaphragm (ASCE 7-05 Sec. 12.11.2 & Sec. 13.3.1)

F anch , seismic = MAX MAX 0.3S DS I p , MIN

Where :

= 5.00 Wp =
ap
=
1.0
(ASCE Tab. 13.5-1)

500 plf (Horizontal)


Rp

1.2a p S DS I p
Rp

, 1.6 S DS I p

(Not applicable)
=
1.5
(1.5, ASCE 13.4.2 or 2.5, ASCE Tab 13.5-1)

Wp

( h+ h p )
2h

, 400 S DS I , F min

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Lateral Force for One-Story Wall Based on IBC 2003


INPUT DATA
WALL THICKNESS
t
PARAPET HEIGHT
hp
WALL HEIGHT
h
TOTAL WALL DENSITY

SEISMIC PARAMETER
SDS
SEISMIC DESIGN CATEGORY SDC
DIAPHRAGM FLEXIBLE ? (0=no, 1=yes)
IMPORTANCE FACTOR
Iw
BASIC WIND SPEED
V
EXPOSURE CATEGORY (B, C, D)
TOPOGRAPHIC FACTOR
KZt

=
=
=
=
=
=
=
=
=
=

8
4
14
150
0.54
C
1
1
90
C
1

in
ft
ft
pcf
(IBC Sec.1615.1.3)
Yes
(IBC Tab. 1604.5)

mph
Flat, (ASCE Eq.6-3)

DESIGN SUMMARY
Out-of-plane force for wall design
w1
=
22.5 psf (Wind governs)
Out-of-plane force for parapet design
w2
=
61.7 psf (Wind governs)
Out-of-plane force for anchorage design
Fanch
=
440 plf (Horizontal direction)
(The governing seismic forces have been reduced by 0.7 for ASD)

WIND ANALYSIS
Out-of-plane wind force for wall design (ASCE 7-02, Eq.6-22)

( G C P ) (G C Pi )

w1,wind = q h

= ( 0.00256 K h K Zt K d V 2 I w ) (G C P ) (G C Pi )

=
0.86
,
Kd
=
0.85
Where :
Kh
(mean roof h =
16 ft, changeable)
(ASCE Tab. 6-4)
(ASCE Tab. 6-3)
Out-of-plane wind force for parapet design (ASCE 7-02, Eq.6-24)

( G C P ) ( G C Pi )

w 2, wind = q p
Where :

=
0.88
Kp
(ASCE Tab. 6-3)

GCp
=
-1.30 ,
(corner ? Yes , TA = 18.67
(ASCE Fig. 6-11A)

Kd
=
0.85
(ASCE Tab. 6-4)

GCp

=
-1.40 ,
=
1.00
2
(TA = 5.333 ft )
(wall, ASCE Fig. 6-11A)

GCpi
=
0.18
(ASCE Fig. 6-5)

ft2 )

= ( 0.00256 K h K Zt K dV 2 I w ) ( G C P ) ( G C Pi )

22.5 psf

61.7 psf, (ASCE7-02,6.5.12.4.4)

GCp
=
-2.80
(roof, ASCE Fig. 6-11B)

GCpi
=
0.18
(roof, ASCE Fig. 6-5)

Out-of-plane wind force for anchorage design

F anch ,wind =

h
hp
w1,wind + h p 1 +
w 2,wind
2
2h

440 plf (Horizontal)

SEISMIC ANALYSIS
Out-of-plane seismic force for wall design (IBC 2003, Sec.1620.2.7)

w1, seismic = MAX ( 0.4 I E S DSW p , 0.1W p )


Where :

Wp

100.0 psf ,

0.22 Wp =

21.6 psf

IE
=
1.0
(IBC Sec.1604.5)

Out-of-plane seismic force for parapet design (ASCE 7-02, Sec. 9.6.1.3)

w 2, seismic = MAX 0.3S DS I pW p , MIN


Where :

ap
=
2.5
,
(ASCE Tab.9.6.2.2)

1.2a p S DS I pW p
Rp

Ip
=
1.0
,
(ASCE Sec. 9.6.1.5)

, 1.6 S DS I pW p

0.65 Wp =

64.8

psf

Rp
=
2.5
(ASCE Tab.9.6.2.2)

Out-of-plane seismic force for anchorage design


For seismic design category A & B, both flexible & rigid diaphragm (IBC 2003, Sec.1604.8.2 & 1620.2.7)

F anch , seismic = MAX 0.4 S DS I EW p


Where :

Fmin
=
280
(IBC Sec.1604.8.2)

( h+ h p )

, 0.1W p

2h

( h+h p )

2h

, 400 S DS I E , F min =

2.80 Wp =
280 plf (Horizontal)
(Not applicable)

plf

For seismic design category C and above, flexible diaphragm (IBC 2003, Sec.1604.8.2 ,1620.2.7, & 1620.3.1)

F anch , seismic = MAX 0.8S DS I EW p

( h+ h p )

, 0.1W p

( h+h p )

, 400 S DS I E , F min =

__
2h

2h

5.00 Wp =
500 plf (Horizontal)
(Applicable)

For seismic design category C and above, rigid diaphragm (IBC 2003, Sec.1604.8.2 ,1620.2.7, & ASCE Sec. 9.6.1.3)

F anch , seismic = MAX MAX 0.3S DS I p , MIN

Where :

= 3.00 Wp =
ap
=
1.0
(ASCE Tab.9.6.2.2)

300 plf (Horizontal)

1.2a p S DS I p
Rp

(Not applicable)

Page 447 of 533


524

, 1.6 S DS I p

Wp

( h+h p )
2h

, 400 S DS I E , F min

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Lateral Force for One-Story Wall Based on IBC 2000


INPUT DATA
WALL THICKNESS
t
PARAPET HEIGHT
hp
WALL HEIGHT
h
TOTAL WALL DENSITY

SEISMIC PARAMETER
SDS
SEISMIC DESIGN CATEGORY SDC
DIAPHRAGM FLEXIBLE ? (0=no, 1=yes)
IMPORTANCE FACTOR
Iw
BASIC WIND SPEED
V
EXPOSURE CATEGORY (B, C, D)
TOPOGRAPHIC FACTOR
KZt

=
=
=
=
=
=
=
=
=
=

8
4
14
150
0.54
C
1
1
90
C
1

in
ft
ft
pcf
(IBC Sec.1615.1.3)
Yes
(IBC Tab. 1604.5)

mph
90
Flat, (ASCE Eq.6-1)

DESIGN SUMMARY
Out-of-plane force for wall design
w1
=
23.9 psf (Wind governs)
=
61.7 psf (Wind governs)
Out-of-plane force for parapet design
w2
=
450 plf (Horizontal direction)
Out-of-plane force for anchorage design
Fanch
(The governing seismic forces have been reduced by 0.7 for ASD)

WIND ANALYSIS
Out-of-plane wind force for wall design (ASCE 7-98, Eq.6-18)

( G C P ) (G C Pi )

w1,wind = q h

= ( 0.00256 K h K Zt K d V 2 I w ) (G C P ) (G C Pi )

=
0.86
,
Kd
=
0.85
Where :
Kh
(mean roof h =
16 ft, changeable)
(ASCE Tab. 6-6)
(ASCE Tab. 6-5)
Out-of-plane wind force for parapet design (ASCE 7-98, Eq.6-18)

( GC P ) ( GC Pi )

w 2, wind = q h
Where :

=
0.88
Kh
(ASCE Tab. 6-5)

GCp
=
-1.40 ,
(corner ? Yes , TA =
10
(ASCE Fig. 6-5A)

GCpi
=
0.18
(ASCE Tab. 6-7)

ft )

= ( 0.00256 K h K Zt K d V 2 I w ) ( GC P ) ( GC Pi )

Kd
=
0.85
(ASCE Tab. 6-6)

GCp

=
-1.40 ,
=
1.00
(wall, ASCE 7-02 Fig. 6-11A)

23.9 psf

61.7 psf

GCp
=
-2.80
(roof, ASCE 7-02 Fig. 6-11B)

GCpi
=
0.18
(roof, ASCE Fig. 6-5)

Out-of-plane wind force for anchorage design

F anch ,wind =

h
hp
w1,wind + h p 1 +
w 2,wind
2
2h

450 plf (Horizontal)

SEISMIC ANALYSIS
Out-of-plane seismic force for wall design (IBC 2000, Sec.1620.1.7)

w1, seismic = MAX ( 0.4 I E S DSW p , 0.1W p )


Where :

Wp

100.0 psf ,

0.22 Wp =

21.6 psf

IE
=
1.0
(IBC Sec.1621.1.6)

Out-of-plane seismic force for parapet design (IBC 2000, Sec. 1621.1.4)

1.2a p S DS I pW p

w 2, seismic = MAX 0.3S DS I pW p , MIN


Where :

=
2.5
ap
(IBC Tab.1621.2)

Rp

Ip
=
1.0
(IBC Sec.1621.1.6)

, 1.6 S DS I pW p

0.65 Wp =

64.8

psf

Rp
=
2.5
(IBC Tab.1621.2)

Out-of-plane seismic force for anchorage design


For seismic design category A & B, both flexible & rigid diaphragm (IBC 2000, Sec.1604.8.2 & 1620.1.7)

F anch , seismic = MAX 0.4 S DS I EW p


Where :

=
200
Fmin
(IBC Sec.1604.8.2)

( h+h p )

, 0.1W p

2h

( h+h p )

0.54

2h

, 400 S DS I E , F min =

2.50 Wp =
250 plf (Horizontal)
(Not applicable)

plf

For seismic design category C and above, flexible diaphragm (IBC 2000, Sec.1604.8.2 ,1620.1.7, & 1620.2.1)

F anch , seismic = MAX 0.8S DS I EW p

( h+h p )

, 0.1W p

( h+h p )

, 400 S DS I E , F min =

__
2h

2h

5.00 Wp =
500 plf (Horizontal)
(Applicable)

For seismic design category C and above, rigid diaphragm (IBC 2000, Sec.1604.8.2 ,1620.1.7, & 1621.1.4)

F anch , seismic = MAX MAX 0.3S DS I p , MIN

Where :

= 3.00 Wp =
ap
=
1.0
(IBC Tab.1621.2)

300 plf (Horizontal)

1.2a p S DS I p
Rp

(Not applicable)

Page 448 of 533


524

, 1.6 S DS I p

Wp

( h+h p )
2h

, 400 S DS I E , F min

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Lateral Force for One-Story Wall Based on 2010 CBC


INPUT DATA
WALL THICKNESS
t
PARAPET HEIGHT
hp
WALL HEIGHT
h
TOTAL WALL DENSITY

SEISMIC PARAMETER
SDS
SEISMIC DESIGN CATEGORY SDC
DIAPHRAGM FLEXIBLE ? (0=no, 1=yes)
SEISMIC IMPORTANCE FACTOR
I
WIND IMPORTANCE FACTOR
I
BASIC WIND SPEED
V
EXPOSURE CATEGORY (B, C, D)
TOPOGRAPHIC FACTOR
KZt

=
=
=
=
=
=

8
4
14
150
0.54
C
1
1.5
1
90
C
1

=
=
=
=
=

in
ft
ft
pcf
(ASCE 7-05 Sec 11.4.4)
Yes
(ASCE 7-05 Tab 11.5-1)
(ASCE 7-05 Tab 6-1)

mph
Flat, (ASCE 6.5.7.2)

DESIGN SUMMARY
Out-of-plane force for wall design
w1
=
22.7 psf (Seismic governs)
Out-of-plane force for parapet design
w2
=
68.0 psf (Seismic governs)
Out-of-plane force for anchorage design
Fanch
=
525 plf (Horizontal direction)
(The governing seismic forces have been reduced by 0.7 for ASD)

WIND ANALYSIS
Out-of-plane wind force for wall design (ASCE 7-05, Eq.6-22)

( GC P ) ( GC Pi )

w1, wind = q h

= ( 0.00256 K h K Zt K dV 2I )

=
0.86
,
Kd
=
0.85
Where :
Kh
(mean roof h =
16 ft, changeable)
(ASCE Tab. 6-4)
(ASCE Tab. 6-3)
Out-of-plane wind force for parapet design (ASCE 7-05, Eq.6-24)

( GC P ) ( GC Pi )

w 2, wind = q p
Where :

=
0.88
Kp
(ASCE Tab. 6-3)

( GC P ) ( GC Pi )

GCp
=
-1.30 ,
(corner ? Yes , TA = 18.67
(ASCE Fig. 6-11A)

Kd
=
0.85
(ASCE Tab. 6-4)

GCp

=
-1.40 ,
=
1.00
2
(TA = 5.333 ft )
(wall, ASCE Fig. 6-11A)

GCpi
=
0.18
(ASCE Fig. 6-5)

ft2 )

= ( 0.00256 K h K Zt K dV 2 I w ) ( G C P ) ( G C Pi )

22.5 psf

61.7 psf, (ASCE 7-05,6.5.12.4.4)

GCp
=
-2.80
(roof, ASCE Fig. 6-11B)

GCpi
=
0.18
(roof, ASCE Fig. 6-5)

Out-of-plane wind force for anchorage design

F anch ,wind =

h
hp
w1,wind + h p 1 +
w 2,wind
2
2h

440 plf (Horizontal)

SEISMIC ANALYSIS
Out-of-plane seismic force for wall design (ASCE 7-05, Sec.12.11.1)

w1, seismic = MAX ( 0.4 I S DSW p , 0.1W p )


Where :

Wp

100.0 psf ,

0.32 Wp =

32.4 psf

1.5

(IBC Tab 1604.5 & ASCE Tab 11.5-1)


Out-of-plane seismic force for parapet design (ASCE 7-05, Sec. 13.3.1)

w 2, seismic = MAX 0.3S DS I pW p , MIN


Where :

ap

2.5

Ip

(ASCE Tab. 13.5-1)

1.2a p S DS I pW p

Rp
1.5

, 1.6 S DS I pW p

Rp

(ASCE Sec. 13.1.3)

0.97 Wp =

97.2

psf

2.5

(ASCE Tab. 13.5-1)

Out-of-plane seismic force for anchorage design


For masonry or concrete under seismic design category A & B, both flexible & rigid diaphragm (ASCE 7-05 Sec. 12.11.2)

F anch , seismic = MAX 0.4 S DS I W

( h+h p )
p

( h+h p )

2h

, 0.1W

2h

, 400 S DS I , F min =

3.75 Wp =
375 plf (Horizontal)
(Not applicable)

Where :

Fmin

280

plf

(2010 CBC 1604.8.2, ASCE Sec. 12.11.2 & 11.7.3)


For seismic design category C and above, flexible diaphragm (ASCE 7-05 Sec. 12.11.2.1)

F anch , seismic = MAX 0.8S DS I W p

( h+h p )
2h

, 0.1W p

( h+h p )
2h

, 400 S DS I , F min =

7.50 Wp =
750 plf (Horizontal)
(Applicable)

For seismic design category C and above, rigid diaphragm (ASCE 7-05 Sec. 12.11.2 & Sec. 13.3.1)

F anch , seismic = MAX MAX 0.3S DS I p , MIN

Where :

= 7.50 Wp =
ap
=
1.0
(ASCE Tab. 13.5-1)

750 plf (Horizontal)


Rp

1.2a p S DS I p
Rp

, 1.6 S DS I p

(Not applicable)
=
1.5
(1.5, ASCE 13.4.2 or 2.5, ASCE Tab 13.5-1)

Wp

( h+ h p )
2h

, 400 S DS I , F min

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Lateral Force for One-Story Wall Based on UBC 97


INPUT DATA
WALL THICKNESS
t
PARAPET HEIGHT
hp
WALL HEIGHT
h
TOTAL WALL DENSITY

SEISMIC ZONE (1, 2A, 2B, 3, or 4)


SEISMIC COEFFICIENT
Ca
IMPORTANCE FACTOR
Ip
BASIC WIND VELOCITY
V
EXPOSURE TYPE (B, C, D)

=
=
=
=

12
2
44
58
4
0.44
1
70
B

=
=
=

in
ft
ft
pcf
Zone 4
(UBC Tab. 16-Q)
(UBC Tab. 16-K)

mph

DESIGN SUMMARY
Out-of-plane force for wall design
w1
=
18.5 psf (Seismic governs)
=
60.8 psf (Seismic governs)
Out-of-plane force for parapet design
w2
Out-of-plane force for anchorage design
Fanch
=
877 plf (Horizontal direction)
(The governing seismic forces have been divided by 1.4 for ASD)

WIND ANALYSIS
Out-of-plane wind force for wall design (UBC 97 Sec.1620)
16.3 psf
w1, wind = C e C q q I w =
s

Where :

Ce
=
0.87
(UBC Tab.16-G)
Mean roof h = 45 ft

Cq
=
1.49
,
qs
=
12.60 psf ,
(UBC Tab.16-H)
(UBC Tab.16-F)
Corner ? Yes (1.5 Yes, 1.2 No)
2
2
TA =
16 ft (10 ft default)

Iw
=
1.00
(UBC Tab.16-K)

[Cq - 0.2 + (100-TA)/450 ] for TA @ [10,100]


Out-of-plane wind force for parapet design (UBC 97 Sec.1620)
16.4 psf
w2, wind = C eC qq s I w =
=
0.87
,
Ce
(UBC Tab.16-G)
Out-of-plane wind force for anchorage design

Cq
TA =

Where :

F anch ,wind = C e C q q s I w
Where :

( h p+h)

=
0.87
Ce
(UBC Tab.16-G)

=
8

1.50
ft2

qs
=
12.60 psf ,
(UBC Tab.16-F)

Iw
=
1.00
(UBC Tab.16-K)

391 plf (Horizontal)

2h
,

Cq
=
1.49
(UBC Tab.16-H)

qs
=
12.60 ,
(UBC Tab.16-F)

Iw
=
1.00
(UBC Tab.16-K)

SEISMIC ANALYSIS
Out-of-plane seismic force for wall design (UBC 97 Sec.1632.2)

w1, seismic =

4a pC a I pW p
1
MAX 0.7C a I pW p , MIN
, 4C a I pW p
2
Rp

MAX 0.7C a I pW p , MIN


Where :

ap

1.0

(UBC Tab.16-O)

Rp

a pC a I pW p
, 4C a I pW p
Rp

3.0

Wp

58.0

0.45 Wp =

25.9 psf

psf

(UBC Tab.16-O)

Out-of-plane seismic force for parapet design (UBC 97 Sec.1632.2)

4a pC a I pW p

w 2, seismic = MAX 0.7C a I pW p , MIN


Where :

ap

2.5

(UBC Tab.16-O)

Rp

, 4C a I pW p

__
Rp

3.0

Wp

58.0

1.47 Wp =

85.1 psf

psf

(UBC Tab.16-O)

Out-of-plane seismic force for anchorage design (UBC 97 Sec.1632.2 & 1633.2.8.1)

F anch, seismic = MAX 0.7C a I pW p , MIN


Where :

ap

1.5

(UBC Tab.16-O)

Rp

4a p C a I pW p

, 4C a I pW p

Rp

3.0

Wp

(UBC Tab.16-O)

Page 450 of 533


524

1395

, F min
plf (Horizontal) ,

0.88 Wp =
1227 plf (Horizontal)

Fmin

420

(UBC 1633.2.8.1)

plf

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Handrail Design Based on AISC 360-05 & ACI 318-08


INPUT DATA & DESIGN SUMMARY
HANDRAIL SECTION

=>

HANDRAIL YIELD STRESS


BALUSTER SECTION

Fy =
35
ksi
= > PIPE-1 1/4

PIPE-1 1/2

BALUSTER YIELD STRESS

Fy =

35

ksi

HANDRAIL SPAN
BALUSTER HEIGHT
BALUSTER SLEEVE DEPTH
EDGE DISTANCE TO SLEEVE

L
H
D
c

=
=
=
=

48
36
4
1

in
in
in
in

CONCRETE STRENGTH
HORIZ. LOAD PERP. TO HANDRAIL

=>
=>

0.80

0.42

0.33

0.15

1.90

0.67

0.31

0.24

0.14

1.66

3
ksi
f c' =
w =
50
plf
(UBC Tab.16-B, IBC 1607.7.1)

THE BRACE DESIGN IS ADEQUATE.


ANALYSIS
CHECK HANDRAIL CAPACITIES (AISC 360-05 F7, G5 or F8, G6)

M=

wL 2
=
8

100 ft-lbs

fb=

M
=
S

3.68 ksi

V =

wL
=
2

100 lbs

(4/3) (M n / b ) / S = (4/3) (F y Z / 1.67) / S =

<

36.09 ksi

[Satisfactory]

16.77 ksi

[Satisfactory]

(where 4/3 from IBC 1607.7.1.3, Typical.)

fv=

V
=
A

(4/3) (0.6 F y C v / v ) = (4/3) (0.6 F y 1.0 / 1.67) =

<

0.25 ksi

CHECK BALUSTER CAPACITIES (AISC 360-05 F7, G5 or F8, G6)

M = wLH =
fb=

M
=
S

fv=

V
=
A

V = wL =

600 ft-lbs

200 lbs

30.64 ksi

<

(4/3) (M n / b ) / S = (4/3) (F y Z / 1.67) / S =

36.27 ksi

[Satisfactory]

0.60 ksi

<

(4/3) (0.6 F y C v / v ) = (4/3) (0.6 F y 1.0 / 1.67) =

16.77 ksi

[Satisfactory]

Vu

[Satisfactory]

CHECK CONCRETE BREAKOUT STRENGTH AT BALUSTER SLEEVE (ACI 318-08 Appendix D)

l
V cb = AV cd ,V c ,VV b = AV cd ,V c ,V 7
AVo

where :

AVo

0.2

'

f c c1.5

0.562 kips

>

0.75

c,V term is 1.0 for location where concrete cracking is likely to occur.
A V /A Vo and cd,V terms are 1.0 for single shear sleeve not influenced by more than one free edge.
is load bearing length of the anchor for shear, not to exceed 8d.
V u = 1.4 V =

0.280

kips

CHECK CONCRETE PRYOUT STRENGTH AT BALUSTER SLEEVE (ACI 318-08 Appendix D)

V cp = k cp A N ed , N c , N N b = k cp A N2

(9D )

A No

=
where :

>

6.901 kips

0.7 +

0.3c
c , N 24 f c' D1.5
1.5 D

__

Vu

[Satisfactory]

c,N term is 1.0 for location where concrete cracking is likely to occur.
k cp

A N = 3 D (1.5D + c) =

2.0

for D > 2.5 in.


2
84.00 in

Page 451 of 533


524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Handrail Design Based on AISC 360-05 & ACI 318-08


INPUT DATA & DESIGN SUMMARY
HANDRAIL SECTION

=>

HANDRAIL YIELD STRESS


BALUSTER SECTION

Fy =
35
ksi
= > PIPE-1 1/4

PIPE-1 1/2

BALUSTER YIELD STRESS

Fy =

35

ksi

HANDRAIL SPAN
BALUSTER HEIGHT
BALUSTER SLEEVE DEPTH
EDGE DISTANCE TO SLEEVE

L
H
D
c

=
=
=
=

48
36
4
1

in
in
in
in

CONCRETE STRENGTH
POINT LOAD PERP. TO HANDRAIL

=>

0.80

0.42

0.33

0.15

1.90

=>

0.67

0.31

0.24

0.14

1.66

3
ksi
f c' =
P = 200 lbs
(UBC Tab.16-B, IBC 1607.7.1)

THE BRACE DESIGN IS ADEQUATE.


ANALYSIS
CHECK HANDRAIL CAPACITIES (AISC 360-05 F7, G5 or F8, G6)

M =

PL
=
4

200 ft-lbs, (P @ middle)

fb=

M
=
S

7.36 ksi

V =P=

200 lbs, (P @ end)

(4/3) (M n / b ) / S = (4/3) (F y Z / 1.67) / S =

<

36.09 ksi

[Satisfactory]

18.67 ksi

[Satisfactory]

(where 4/3 from IBC 1607.7.1.3, Typical.)

fv=

V
=
A

(4/3) (0.6 F y C v / v ) = (4/3) (0.6 F y 1.0 / 1.67) =

<

0.50 ksi

CHECK BALUSTER CAPACITIES (AISC 360-05 F7, G5 or F8, G6)

M = PH =

V =P=

600 ft-lbs

200 lbs

fb=

M
=
S

30.64 ksi

<

(4/3) (M n / b ) / S = (4/3) (F y Z / 1.67) / S =

36.27 ksi

[Satisfactory]

fv=

V
=
A

0.60 ksi

<

(4/3) (0.6 F y C v / v ) = (4/3) (0.6 F y 1.0 / 1.67) =

18.67 ksi

[Satisfactory]

Vu

[Satisfactory]

CHECK CONCRETE BREAKOUT STRENGTH AT BALUSTER SLEEVE (ACI 318-08 Appendix D)

l
V cb = AV cd ,V c ,VV b = AV cd ,V c ,V 7
AVo

where :

AVo

0.2

'

f c c1.5

0.562 kips

>

0.75

c,V term is 1.0 for location where concrete cracking is likely to occur.
A V /A Vo and cd,V terms are 1.0 for single shear sleeve not influenced by more than one free edge.
is load bearing length of the anchor for shear, not to exceed 8d.
V u = 1.4 V =

0.280

kips

CHECK CONCRETE PRYOUT STRENGTH AT BALUSTER SLEEVE (ACI 318-08 Appendix D)

V cp = k cp A N ed , N c , N N b = k cp A N2

(9D )

A No

=
where :

>

6.901 kips

0.7 +

0.3c
c , N 24 f c' D1.5
1.5 D

__

Vu

[Satisfactory]

c,N term is 1.0 for location where concrete cracking is likely to occur.
k cp

A n = 3 D (1.5D + c) =

2.0

for D > 2.5 in.


2
84.00 in

Page 452 of 533


524

PROJECT :
CLIENT :
JOB NO. :
DATE :
Sign Design Based on AISC 360-05, ACI 318-08, and IBC 09 1807.3
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION (Tube, Pipe, or WF)

HSS8X8X5/16
Fy =
L=

COLUMN YIELD STRESS


DIMENSIONS

46
20

ksi
ft

HS =

ft

HC =

10

ft

SIGN GRAVITY LOAD ( lbs / ft2 )

D=

10

psf

SIGN LATERAL LOAD ( lbs / ft2 )


COLUMN LATERAL LOAD ( plf )
DIAMETER OF POLE FOOTING

W=
F=
b=

25
8
2

psf, ASD
plf, ASD
ft

ksf

ALLOW SOIL PRESSURE

Qa =

LATERAL SOIL CAPACITY


RESTRAINED @ GRADE ?(1=yes,0=no)

PP =

PAGE :
DESIGN BY :
REVIEW BY :

Tube

0.266 ksf / ft
0
No

Use 2 ft dia x 8.61 ft deep footing unrestrained @ ground level

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY OF COLUMN (AISC 360-05, H1)

P r + 8 M rx + M ry
P c 9 M cx M cy

, for P r 0.2
Pc

P r + M rx + M ry
2 P c M cx M cy

, for P r < 0.2


Pc

Where

Pr =

1.68

kips

M rx =

56.4

ft-kips, at bottom of column

M ry =

16.92

ft-kips,

Pc = Pn / c =

292

30%

[Satisfactory]

M rx used
Pr

[Satisfactory]

M cx = M n / b =

96.217 / 1.67 = 57.615 ft-kips, (AISC 360-05 Chapter F)

M cy = M n / b =

96.217 / 1.67 = 57.615 ft-kips, (AISC 360-05 Chapter F)

>
>
DESIGN POLE FOOTING (IBC 09 1807.3)
By trials, use pole depth, d =
8.606 ft
Lateral bearing @ bottom, S 3 = 2 P P Min( d , 12' ) =
Lateral bearing @ d / 3, S 1 = 2 P P Min( d / 3 , 12' ) =
Require Depth is given by

A
4.36 h
1+ 1+
2
A
4.25 Ph
bS 3

Where

4/3

/ 1.67 = 175.01 kips, (AISC 360-05 Chapter E)

>

d =

<

1.28

3/4 M rx
3/4 M ry

[Satisfactory]
[Satisfactory]

4.58

ksf

1.53

ksf

for nonconstrained

8.606

ft

[Satisfactory]

for constrained

P = V max =

4.08

A = 2.34 P / (b S 1 ) =

kips
3.13

__

h = M max / V max =

13.82

ft

CHECK VERTICAL SOIL BEARING CAPACITY (ACI, Sec. 15.2.2)


q soil = (D H S L + col wt ) / ( b 2 / 4) =

0.53

ksf, (net weight of pole footing included.)

<

Page 453 of 533


524

Qa

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :
DATE :
Sign Design Based on AISC 360-05, ACI 318-08, and IBC 09 1807.3
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION (WF, Tube, or Pipe)

W8X24

COLUMN YIELD STRESS


DIMENSIONS

Fy =
L=

W Shape

50
20

ksi
ft

HS =

ft

HC =

10

ft

2
SIGN GRAVITY LOAD ( lbs / ft )

D=

10

psf

2
SIGN LATERAL LOAD ( lbs / ft )
COLUMN LATERAL LOAD ( plf )
DIAMETER OF POLE FOOTING

W=
F=
b=

25
8
3

psf, ASD
plf, ASD
ft

ksf

ALLOW SOIL PRESSURE

Qa =

LATERAL SOIL CAPACITY


RESTRAINED @ GRADE ?(1=yes,0=no)

PP =

PAGE :
DESIGN BY :
REVIEW BY :

0.266 ksf / ft
0
No

Use 3 ft dia x 5.73 ft deep footing unrestrained @ ground level

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY OF COLUMN (AISC 360-05, H1)

P r + 8 M rx + M ry
P c 9 M cx M cy

, for P r 0.2
Pc

P r + M rx + M ry
2 P c M cx M cy

, for P r < 0.2


Pc

Where

Pr =

0.86

kips

M rx =

28.4

ft-kips, at bottom of column

M ry =

8.52

ft-kips,

Pc = Pn / c =

98

30%

[Satisfactory]

M rx used
Pr

[Satisfactory]

M cx = M n / b =

63.567 / 1.67 = 38.064 ft-kips, (AISC 360-05 Chapter F)

M cy = M n / b =

35.708 / 1.67 = 21.382 ft-kips, (AISC 360-05 Chapter F)

>
>
DESIGN POLE FOOTING (IBC 09 1807.3)
By trials, use pole depth, d =
5.73 ft
Lateral bearing @ bottom, S 3 = 2 P P Min( d , 12' ) =
Lateral bearing @ d / 3, S 1 = 2 P P Min( d / 3 , 12' ) =
Require Depth is given by

A
4.36 h
1+ 1+
2
A
4.25 Ph
bS 3

Where

4/3

/ 1.67 = 58.956 kips, (AISC 360-05 Chapter E)

>

d =

<

1.15

3/4 M rx
3/4 M ry

[Satisfactory]
[Satisfactory]

3.05

ksf

1.02

ksf

for nonconstrained

5.73

ft

[Satisfactory]

for constrained

P = V max =

2.08

kips

A = 2.34 P / (b S 1 ) =

1.59

h = M max / V max =

13.65

ft

__

CHECK VERTICAL SOIL BEARING CAPACITY (ACI, Sec. 15.2.2)


2
q soil = (0.5 D H S L + col wt ) / ( b / 4) =

0.12

ksf, (net weight of pole footing included.)

<

Page 454 of 533


524

Qa

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Freestanding Wall & Sign Based on ASCE 7-2010
INPUT DATA
Exposure category (B, C or D)
Importance factor, 1.0 only, (Table 1.5-2)

Iw
V
Kzt
h
s
B
Lr

Basic wind speed (ASCE 7-10 26.5.1)


Topographic factor (26.8 & Table 26.8-1)

Height of top
Vertical dimension (for wall, s = h)
Horizontal dimension
Dimension of return corner

=
=
=
=
=
=
=
=

C
1.00
136
1
35
8
100
2

mph
Flat
ft
ft
ft
ft

DESIGN SUMMARY
Max horizontal wind pressure
Max total horizontal force at centroid of base
Max bending moment at centroid of base
Max torsion at centroid of base

p
F
M
T

=
=
=
=

125
51.09
1583.73
1021.76

psf
kips
ft-kips
ft-kips

ANALYSIS
Velocity pressure

qh = 0.00256 Kh Kzt Kd V2
where:

40.65

psf

qh = velocity pressure at mean roof height, h. (Eq. 29.3-1 page 307 & Eq. 30.3-1 page 316)
Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 29.3-1, pg 310)
Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250)
h = height of top

1.01

=
=

0.85
35.00

0.85

ft

Wind Force Case A: resultant force though the geometric center (Sec. 29.4.1 & Fig. 29.1-1)

p = q h G Cf =

F = p As
M = F (h - 0.5s) for sign, F (0.55h) for wall
T=

=
=
=

where:

64

psf

51.09 kips
1583.73 ft-kips
0.00 ft-kips

G = gust effect factor. (Sec. 26.9)


Cf = net force coefficient. (Fig. 29.4-1, page 311)

1.85

As = B s

Wind Force Case B: resultant force at 0.2 B offset of the geometric center (Sec. 29.4.1 & Fig. 29.1-1)
=
64
psf
p = Case A
=
51.09 kips
F = Case A
=
1583.73 ft-kips
M = Case A
=
1021.76 ft-kips
T = 0.2 F B
Wind Force Case C: resultant force different at each region (Sec. 29.4.1 & Fig. 29.1-1)

p = q h G Cf
F = p As
M = [ F (h - 0.5s) for sign, F (0.55h) for wall ]
T = Ts

3.63
2.58
1.98
1.41
1.28
0.91
0.90

Distance

0
1
2
3
4
5
10
B

(ft)
8.0
16.0
24.0
32.0
40.0
80.0
100.0

Cf
(Fig.6-20)
3.628
2.575
1.975
1.408
1.283
0.908
0.901

Pi

Asi

Fi

Mi

Ti

(psf)
125
89
68
49
44
31
31

(ft2)
64
64
64
64
64
64
160

(kips)
8.02
5.69
4.37
3.11
2.84
2.01
4.98
31.02

(ft-kips)
248.74
176.52
135.39
96.54
87.97
62.27
154.34
961.77

(ft-kips)
369.10
216.38
131.02
68.51
39.73
-20.09
-199.14
605.51

800.0

ft2

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

MCE Level Seismic Design for Metal Pipe/Riser Based on ASCE 7-10 & AISI S100
INPUT DATA & DESIGN SUMMARY
BUILDING STORY HEIGHT

H=

18

ft

METAL YIELD STRESS (33 or 55)

Fy =

55

ksi

SECTION SIZE

w=
d=
t=

48
84
43

in
in
mils

18

Gauge)

'drift =

MAX STORY DRIFT (MCE level)


Trotation =

ALLOWABLE ROTATION

0.028

in, ( < 0.04 H, CBC 2205A.4.1.1)

rad, (detail/site verify, < 0.03)

THE DESIGN IS ADEQUATE.


ANALYSIS
DETERMINE SECTION FORCES BY FULL SECTION CONSERVATIVELY
EA/L

-EA/L

1598.544

0.000

0.000

-1598.544

0.000

0.000

12EI/((1+E)L3)

6EI/((1+E)L2)

-12EI/((1+E)L3)

6EI/((1+E)L2)

0.000

230.068

24847.334

0.000

-230.068

24847.334

-6EI/((1+E)L2)

(2-E)EI/((1+E)L)

1059972.212

EA/L

12EI/((1+E)L3)

[k] =

(4+E)EI/((1+E)L)

Where

=
=
=
=

L
E
G
E

{F} = [k] {'


'} = [k]

18
29000

0.000

0.000

11.043

0.028
0.000

24847.334

4307051.945

0.000

-24847.334

0.000

0.000

1598.544

0.000

0.000

-6EI/((1+E)L2)

0.000

-230.068

-24847.334

0.000

230.068

-24847.334

(4+E)EI/((1+E)L)

0.000

24847.334

1059972.212

0.000

-24847.334

4307051.945

=
=
=
=

0.0451

ft

thk

ksi

11153.85 ksi
12 E I k / (G A L2 ) =

0.000

0.000
-1598.544

1192.672

I
0.815

11.91

in
in2

12092.57

in4

1.2

V=

11.043

kips, SD

7.730

kips, ASD

M=

1193

in-k, SD

69.6

ft-k, ASD

0.000

6.000

-11.043

0.028

1192.672

CHECK FLEXURAL CAPACITY BY EFFECTIVE SECTION ON FOUR LEGS (AISI C3.1)


Mn/:
:b =

Fy Ieff / (0.5 d :b) =

94.1

ft-kips

>

Where

M
[Satisfactory]
b = 200 (thk) =
9.02
in, (AISI B1.2a)
4
Ieff = 2 (thk) b3 / 12 + 2 (thk) b (0.5 d)2 =
1440.71 in
:b =

1.67

CHECK SHEAR CAPACITY BY EFFECTIVE SECTION ON TWO LEGS (AISI C3.2)


Vn/:
:V =

Fy Aeff / (:v) =

27.968

kips

>
Where

Aeff = 2 (thk) b =
:v =

[Satisfactory]

in2

0.81

1.60

CHECK CAPACITY COMBINED BENDING & SHEAR AT THE SAME SECTION (AISI C3.3.1)

2
:bM : vV


Mn Vn

: M
b
Mn

2
=

>

0.74

: M : V
0.6 b  v
Mn Vn

<

0.788998

1.0

[Satisfactory]

: V
v
Vn

0.5

<

1.3

[Satisfactory]

0.28

<

0.7

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Freestanding Wall & Sign Based on ASCE 7-05
INPUT DATA
Exposure category (B, C or D)
Importance factor, pg 73, (0.87, 1.0 or 1.15)
Basic wind speed (3 sec. gust wind)
Topographic factor (Sec.6.5.7.2, pg 26 & 45)

Height of top
Vertical dimension (for wall, s = h)
Horizontal dimension
Dimension of return corner

I
V
Kzt
h
s
B

=
=
=
=
=
=
=

C
1.00
90
1
35
8
100

Lr

Category II
mph
Flat
ft
ft
ft

ft

DESIGN SUMMARY
Max horizontal wind pressure
Max total horizontal force at centroid of base
Max bending moment at centroid of base
Max torsion at centroid of base

p
F
M
T

=
=
=
=

55
22.37
693.57
447.46

psf
kips
ft-kips
ft-kips

ANALYSIS
Velocity pressure

qh = 0.00256 Kh Kzt Kd V2 I
where:

17.80 psf

qh = velocity pressure at mean roof height, h. (Eq. 6-15, page 27)


Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-3, Case 1,pg 79)

1.01

Kd = wind directionality factor. (Tab. 6-4, for building, page 80)


h = height of top

=
=

0.85
35.00

0.85

800.0

ft

Wind Force Case A: resultant force though the geometric center (Sec. 6.5.14 & Fig. 6-20)

p = qh G C f =

F = p As
M = F (h - 0.5s) for sign, F (0.55h) for wall
T=

=
=
=

where:

28

psf

22.37 kips
693.57 ft-kips
0.00 ft-kips

G = gust effect factor. (Sec. 6.5.8, page 26).


Cf = net force coefficient. (Fig. 6-20, page 73)

1.85

As = B s
Wind Force Case B: resultant force at 0.2 B offset of the geometric center (Sec. 6.5.14 & Fig. 6-20)
p = Case A
=
28
psf
F = Case A
=
22.37 kips
M = Case A
=
693.57 ft-kips
T = 0.2 F B
=
447.46 ft-kips
Wind Force Case C: resultant force different at each region (Sec. 6.5.14 & Fig. 6-20)

p = qh G C f
F = p As
M = [ F (h - 0.5s) for sign, F (0.55h) for wall ]
T = Ts
s
3.63
2.58
1.98
1.41
1.28
0.91
0.90

0
1
2
3
4
5
10
B

Distance
(ft)
8.0
16.0
24.0
32.0
40.0
80.0
100.0

Cf
(Fig.6-20)
3.628
2.575
1.975
1.408
1.283
0.908
0.901

Pi
(psf)
55
39
30
21
19
14
14

Asi
2

(ft )
64
64
64
64
64
64
160

Fi

Mi

Ti

(kips)
3.51
2.49
1.91
1.36
1.24
0.88
2.18
13.59

(ft-kips)
108.93
77.30
59.29
42.28
38.53
27.27
67.59
421.19

(ft-kips)
161.64
94.76
57.38
30.00
17.40
-8.80
-87.21
265.17

__
Page 455 of 533
524

ft2

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Snow Load Analysis Based on ASCE 7-2010


INPUT DATA & DESIGN SUMMARY
BASIC GROUND SNOW LOAD (ASCE Sec. 7.2)

Pg =

20

psf, (ASCE page 29)

Pf, roof =

15.75

psf

SNOW EXPOSURE FACTOR

Ce =

(Tab. 7-2, pg 30)

Pf, overhang =

33.60

psf

THERMAL FACTOR (0.85 , 1.0 , 1.1 , 1.2, or 1.3)

Ct =

1.2

(Tab. 7-3, pg 30)

Pf, valley =

33.60

psf

IMPORTANCE FACTOR

Is =

(Tab. 1.5-1 & 1.5-2, 7.3.3 pg 29)

Pf, parapet =

38.06

psf

5.38

ft

ROOF SLOPE

4 / 12

Wd =

PARAPET HEIGHT (DRIFT CORNER HEIGHT)

hr =

ft, see fig. below

LENGTH OF THE ROOF UPWIND OF THE DRIFT


OBSTRUCTED SLIPPERY SURFACE (Sec. 7.4, pg 31 & 36) ? (1=Yes, 0=No)

Lu =

35

ft, see fig. below

P1 =

25.00

psf

Unobstructed

P2 =

20.75

psf

P3 =

6.23

psf

P4 =
x=

33.63
6.21

psf
ft

ANALYSIS
FLAT SNOW LOADS (Sec 7.3, pg 29)
Pf = 0.7CeCt Is Pg =
Where

16.80

Droof =
W=

18.4
17.5

Pf, min =

0.00

psf
0

ft
psf, (Sec. 7.3.4, pg 29)

ROOF SNOW LOADS (Sec. 7.4, pg 31)


Ps = Cs Pf =
Where

15.75
Cs =

psf, (Eq.7.4-1)

0.938
, Derived from Fig 7-2, page 86, as following table

Ct

0.85 or 1.0

1.1

1.2 or 1.3

Unobstructed

Cs,1

Cs,3

Cs,5

Obstructed

Cs,2

Cs,4

Cs,6

Cs,1 = MIN [ (70 - D) / 65, 1.0]

, Fig. 7-2a dash line

Cs,2 = MIN [ (70 - D) / 40, 1.0]

, Fig. 7-2a solid line

Cs,3 = MIN [ (70 - D) / 60, 1.0]

, Fig. 7-2b dash line

Cs,4 = MIN [ (70 - D) / 32.5, 1.0]

, Fig. 7-2b solid line

Cs,5 = MIN [ (70 - D) / 55, 1.0]

, Fig. 7-2c dash line

Cs,6 = MIN [ (70 - D) / 25, 1.0]

, Fig. 7-2c solid line

SNOW LOADS AT OVERHANG, VALLEY, AND PARAPET CORNER


Pf, overhang = 2 Pf =

33.60

psf, (Sec.7.4.5, pg 31)

Pf, valley = Cv Pf =

33.60

psf, (Sec.7.6.3, pg 32)

Where

Cv = 2 / Ce =

2.00

, (Fig. 7-6, pg 40)

Pf, parapet = Cd Ps = MIN[J(hd + hb), Jhr]


=
38.06
psf, (Sec.7.7.1, pg 32)
Where

J = MIN(0.13Pg+ 14, 30) =

16.60

pcf, (7.7-1)

hb = Ps / J =

0.95

ft, (Sec. 7.1)

hc = hr - hb =

3.05

ft, (Fig. 7.8)

hc / hb =

3.22
>
0.2, (Sec.7.7.1)
(Drift load need be considered)

hd = 0.75 [0.43(Lu)1/3(Pg+ 10)1/4 - 1.5]


=
1.34
ft, (Sec.7.8 & Fig.7-9)
Cd =
Wd =

2.42

4hd =

, (see fig. right)


5.38

ft, for hd<hc

4hd2 / hc =
N/A
(Sec.7.7.1, pg 33)

ft, for hd>hc

W d,max = 8 hc =

24.41

ft

ROOF UNBALANCED SNOW LOADS


Psurcharge =

5.00

psf, (Sec. 7.10, pg 33)

P1 = Psurcharge + Is Pg =

Note :

25.00

psf, (unbalanced load, Fig 7-5)

P2 = (Psurcharge + Ps) =

20.75

psf, (unbalanced load, Fig 7-5)

P3 = 0.3 P2 =

6.23

psf, (unbalanced load, Fig 7-5)

P4 = P2 + hd J / (1 / Tan Droof)0.5 =

33.63

psf

x = (8 / 3) hd (1 / Tan Droof)0.5 =

6.21

ft

Where flat roof snow loads exceed 30 psf, the seismic dead load shall include 20% design snow load. (ASCE 7-10 Sec. 12.7.2.4)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Snow Load Analysis Based on UBC 97


INPUT DATA & DESIGN SUMMARY (UBC Sec. 1614)
TOTAL SNOW LOAD

S =

75

psf

PITCH DEGREE

30

wsnow = S - Rs( - 20) =


Where

Rs =

61.3

psf

psf, (for > 20o)


S/40 - 1/2 = 1.375
o
(for < 20 )
N/A

INPUT DATA & DESIGN SUMMARY (UBC / CBC Appendix Chapter 16)
BASIC GROUND SNOW LOAD

Pg =

35

psf

SNOW EXPOSURE FACTOR

Ce =

0.9

(Tab. A-16-A)

Pf, roof =

31.50

psf

(Tab. A-16-B)

Pf, overhang =

63.00

psf
psf

IMPORTANCE FACTOR

I =

OBSTRUCTED SLIPPERY SURFACE ON ROOF ? (1=Yes, 0=No)


HEATED GREENHOUSES ? (1=Yes, 0=No)
ROOF SLOPE
PARAPET HEIGHT (DRIFT CORNER HEIGHT)
LENGTH FROM PARAPET TO ROOF EDGE

Unobstructed

Pf, valley =

59.72

==>

Unheated

Pf, parapet =

51.38

psf

18

4.29

ft

hr =
W =

4
35

ft, see fig. below


ft, see fig. below

Wd =

THE ROOF SNOW LOADS (CBC 40-1-1)


Pf = Ce I Pg =

31.50

psf

THE APPLICABLE ROOF SNOW LOADS (CBC Sec. 1640)


Pf, roof = Cs Pf =
Where

31.50

psf

CsPf is derived from CBC Sec.1640 as following table


Pg
Unheated
Heated

[0, 20]

(20, 70]

(70, 100]

Max(Cs,1Pf, Pg)

Max(Cs,1Pf, 20)

Max(Cs,1Pf, 70CeI)

Max(Cs,5Pf, 70CeI)

Obstructed

Max(Cs,2Pf, Pg)

Max(Cs,2Pf, 20)

Max(Cs,2Pf, 70CeI)

Max(Cs,5Pf, 70CeI)

Unobstructed

Max(Cs,3Pf, Pg)

Max(Cs,3Pf, 20)

Max(Cs,3Pf, 70CeI)

Max(Cs,5Pf, 70CeI)

Obstructed

Max(Cs,4Pf, Pg)

Max(Cs,4Pf, 20)

Max(Cs,4Pf, 70CeI)

Max(Cs,5Pf, 70CeI)

Cs,1 = MIN [ 1-( - 30) / 40, 1.0]

, CBC (40-2-1)

Cs,2 = MIN [ 1-( - 45) / 25, 1.0]

, CBC (40-2-2)

Cs,3 = MIN [ 1-( - 15) / 55, 1.0]

, CBC (40-2-3)

Cs,4 = MIN [ 1-( - 30) / 40, 1.0]

, CBC (40-2-4)

Cs,5 = MIN [ 1-( - 20)(Pf - 20) / (40Pf), 1.0]

, CBC (40-2-5)

THE SNOW LOADS AT OVERHANG, VALLEY, AND PARAPET CORNER


Pf, overhang = 2 Pf, roof =

63.00

Pf, valley = Cv Pf, roof =

59.72

Where

=
Cv =

90
1.90

psf, (CBC Fig. A-16-10)


psf, (CBC Fig. A-16-12)
o

, roof intersection angle

(CBC Fig. A-16-11)

Pf, parapet = Cd Pf, roof = Pm = MIN[D(hd + hb), Dhr]


=
51.38
psf, (CBC Eq. 44-4)
Where

D = MIN(0.13Pg+ 14, 35) =

18.55

pcf, (44-2)

hb = Pf, roof / D =

1.70

ft, (44-3)

(hr - hb) / hb =

1.36
>
0.2, (44-3)
(Drift load need be considered)

Wb = MIN[ W , 50] =

35.00

hd = 0.5 [0.43(Wb)1/3(Pg+ 10)1/4 - 1.5]


=
1.07

Note :

(100, greater]

Unobstructed

Cd = Pm/ Pf, roof =

1.63

Wd = MIN[4(hr - hb), 4hd] =

4.29

ft, (Sec.1644.5)
ft,(1644.5 & 44-1)
ft, (Sec.1644.2)

__

Where design snow loads exceed 30 psf, the seismic dead load shall include 25% design snow load. (UBC 1630.1.1)

Page 457 of 533


524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Snow Load Analysis Based on ASCE 7-05 / IBC 2009


INPUT DATA & DESIGN SUMMARY
BASIC GROUND SNOW LOAD (ASCE Sec. 7.2)

Pg =

20

(ASCE page 81)

Pf, roof =

15.75

psf

SNOW EXPOSURE FACTOR

Ce =

(Tab. 7-2, pg 92)

Pf, overhang =

33.60

psf

THERMAL FACTOR (0.85 , 1.0 , 1.1 , 1.2)

Ct =

1.2

(Tab. 7-3, pg 93)

Pf, valley =

33.60

psf

(Tab. 7-4, pg 93)

Pf, parapet =

38.06

psf

5.38

ft

IMPORTANCE FACTOR

I =

ROOF SLOPE

4 / 12

Wd =

PARAPET HEIGHT (DRIFT CORNER HEIGHT)

hr =

ft, see fig. below

LENGTH OF THE ROOF UPWIND OF THE DRIFT


OBSTRUCTED SLIPPERY SURFACE (Sec. 7.4.0, pg 81) ? (1=Yes, 0=No)

Lu =

35

ft, see fig. below

P1 =

25.00

psf

Unobstructed

P2 =

20.75

psf

P3 =

6.23

psf

P4 =
x=

33.63
6.21

psf
ft

ANALYSIS
FLAT SNOW LOADS (Sec 7.3, pg 81)
Pf = 0.7CeCt I Pg =
Where

16.80

Droof =
W=

18.4
17.5

Pf, min =

0.00

psf
0

ft
psf, (Sec. 7.3.4, pg 81)

ROOF SNOW LOADS (Sec. 7.4, pg 81)


Ps = Cs Pf =
Where

15.75
Cs =

psf, (Eq.7-2)

0.938
, Derived from Fig 7-2, page 86, as following table
0.85 or 1.0

1.1

1.2

Unobstructed

Ct

Cs,1

Cs,3

Cs,5

Obstructed

Cs,2

Cs,4

Cs,6

Cs,1 = MIN [ (70 - D) / 65, 1.0]

, Fig. 7-2a dash line

Cs,2 = MIN [ (70 - D) / 40, 1.0]

, Fig. 7-2a solid line

Cs,3 = MIN [ (70 - D) / 60, 1.0]

, Fig. 7-2b dash line

Cs,4 = MIN [ (70 - D) / 32.5, 1.0]

, Fig. 7-2b solid line

Cs,5 = MIN [ (70 - D) / 55, 1.0]

, Fig. 7-2c dash line

Cs,6 = MIN [ (70 - D) / 25, 1.0]

, Fig. 7-2c solid line

SNOW LOADS AT OVERHANG, VALLEY, AND PARAPET CORNER


Pf, overhang = 2 Pf =

33.60

psf, (Sec.7.4.5, pg 82)

Pf, valley = Cv Pf =

33.60

psf, (Sec.7.6.3, pg 82)

Where

Cv = 2 / Ce =

2.00

, (Fig. 7-6, pg 90)

Pf, parapet = Cd Ps = MIN[J(hd + hb), Jhr]


=
38.06
psf, (Sec.7.7.1, pg 83)
Where

J = MIN(0.13Pg+ 14, 30) =

16.60

pcf, (7-3)

hb = Ps / J =

0.95

ft, (Sec. 7.1)

hc = hr - hb =

3.05

ft, (Fig. 7.8)

hc / hb =

3.22
>
0.2, (Sec.7.7.1)
(Drift load need be considered)

hd = 0.75 [0.43(Lu)1/3(Pg+ 10)1/4 - 1.5]


=
1.34
ft, (Sec.7.8 & Fig.7-9)
Cd =
Wd =

2.42

4hd =

, (see fig. right)


5.38

ft, for hd<hc

4hd2 / hc =
N/A
(Sec.7.7.1, pg 83)

ft, for hd>hc

W d,max = 8 hc =

24.41

ft

ROOF UNBALANCED SNOW LOADS


Psurcharge =

Note :

5.00

psf, (Sec. 7.10, pg 83)

P1 = Psurcharge + I Pg =

25.00

psf, (unbalanced load, Fig 7-5)

P2 = (Psurcharge + Ps) =

20.75

psf, (unbalanced load, Fig 7-5)

P3 = 0.3 P2 =

6.23

psf, (unbalanced load, Fig 7-5)

P4 = P2 + hd J / (1 / Tan Droof)0.5 =

33.63

psf

x = (8 / 3) hd (1 / Tan Droof)0.5 =

6.21

ft

Where flat roof snow loads exceed 30 psf, the seismic dead load shall include 20% design snow load. (ASCE 7-05 Sec. 12.7.2.4)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Live Load Reduction Based on ASCE 7-2010


INPUT DATA & DESIGN SUMMARY
MEMBER TYPE (0=Beam, 1=Column)

1
975
Ar =
1 / 12
4
n =
AT =
3900

ROOF TRIBUTARY AREA SUPPORTED BY THE MEMBER


ROOF SLOPE
NUMBER OF FLOORS
TOTAL FLOOR TRIBUTARY AREA SUPPORTED BY THE MEMBER
FLOOR LIVE LOAD (ASCE 7-10 Table 4.1, page 17)
FLOOR DEAD LOAD (for IBC/CBC Eq. 16-24)
GROUP A OCCUPANCIES ? (0=No, 1=Yes) (IBC/CBC 1607.9.2.1)

L0 =
D =

100
70
0

ft2
psf
psf
No

UNIFORM
12.00
psf
49.02
psf

THE MINIMUM ROOF LIVE LOAD


THE MINIMUM FLOOR LIVE LOAD
TOTAL LOAD SUPPORTED BY THE COLUMN

Column
ft2, (if no roof, input 0.)

11.70
191.17
202.87

kips
kips
kips

Note: Live loads are horizontal projected loads.


ANALYSIS
MINIMUM ROOF LIVE LOAD (ASCE 7-10 4.8)
L r = L 0 R1 R2 =
Where

12.00

psf

L0 =

20

R1 =

0.60

psf, (ASCE 7-10 Table 4-1, page 18)

TRIBUTARY AREA

[ 0 ~ 200]

( 200 ~ 600)

[ 600 ~ over)

1.2 -0.001 A f

0.6

[ 0 ~ 4] / 12

( 4 ~ 12) / 12

1.2 -0.05 F

R1
R2 =

1.00
ROOF SLOPE, F / 12
R2

Lr =

[ 12 ~ over) / 12
0.6

[ 12 , 20 ]

MINIMUM FLOOR LIVE LOAD BY INFLUENCE AREA METHOD (ASCE 7-10 4.7.2, page 15)
L = L0 [ 0.25 + 15 / (A I)0.5 ] =
Where

49.02

L0 =

100

KLL =

AI=

KLL AT =

psf

<==

psf

note: 1. Min reduced ,L, 50% for one level only, 40% for others.
2. Column live reaction can not be used to design footing,
since KLL different per ASCE 7-10 Table 4-2.

,(ASCE 7-10 Table 4-2)


15600

ft2

MINIMUM FLOOR LIVE LOAD BY TRIBUTARY AREA METHOD (IBC/CBC 1607.9.2)


L = (100 psf ) x (100 - R) / 100 =
60.73
psf
Where
r =
0.08
r ( AT - 150 ) =
R =
39.3

<==

note: 1. For floor live loads exceeding 100 psf, no reduction


shall be made, except that design live loads on columns
may be reduced 20 percent.
2. Max reduction ,R, per Eq 16-23, and 40% for one level only,
60% for others.
3. No reduction permitted in Group A occupancies.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Live Load Reduction Based on IBC 2009 / CBC 2010


INPUT DATA & DESIGN SUMMARY
MEMBER TYPE (0=Beam, 1=Column)

1
975
Ar =
1 / 12
4
n =
AT =
3900

ROOF TRIBUTARY AREA SUPPORTED BY THE MEMBER


ROOF SLOPE
NUMBER OF FLOORS
TOTAL FLOOR TRIBUTARY AREA SUPPORTED BY THE MEMBER
FLOOR LIVE LOAD (IBC Table 1607.1)
FLOOR DEAD LOAD (for Eq. 16-24)
GROUP A OCCUPANCIES ? (0=No, 1=Yes) (IBC 1607.9.2.1)

L0 =
D =

100
70
0

ft2
psf
psf
No

UNIFORM
12.00
psf
40.00
psf

THE MINIMUM ROOF LIVE LOAD


THE MINIMUM FLOOR LIVE LOAD
TOTAL LOAD SUPPORTED BY THE COLUMN

Column
ft2, (if no roof, input 0.)

11.70
156.00
167.70

kips
kips
kips

Note: Live loads are horizontal projected loads.


ANALYSIS
MINIMUM ROOF LIVE LOAD (IBC 1607.11.2)
L r = L 0 R1 R2 =
Where

12.00

psf

L0 =

20

R1 =

0.60

psf, (IBC Tab 1607.1 Item 30)

TRIBUTARY AREA

[ 0 ~ 200]

( 200 ~ 600)

[ 600 ~ over)

1.2 -0.001 A f

0.6

[ 0 ~ 4] / 12

( 4 ~ 12) / 12

1.2 -0.05 F

R1
R2 =

1.00
ROOF SLOPE, F / 12
R2

Lr =

[ 12 ~ over) / 12
0.6

[ 12 , 20 ]

MINIMUM FLOOR LIVE LOAD BY INFLUENCE AREA METHOD (IBC 1607.9.1)


L = L0 [ 0.25 + 15 / (A I)0.5 ] =
Where

40.00

L0 =

100

KLL =

AI=

KLL AT =

psf

<==

psf

note: 1. Min reduced ,L, 50% for one level only, 40% for others.
2. Column live reaction can not be used to design footing,
since KLL different per Table 1607.9.1.

,(IBC Table 1607.9.1)


15600

ft2

MINIMUM FLOOR LIVE LOAD BY TRIBUTARY AREA METHOD (IBC 1607.9.2)


L = (100 psf ) x (100 - R) / 100 =
60.73
psf
Where
r =
0.08
r ( AT - 150 ) =
R =
39.3

<==

note: 1. For floor live loads exceeding 100 psf, no reduction


shall be made, except that design live loads on columns
may be reduced 20 percent.
2. Max reduction ,R, per Eq 16-23, and 40% for one level only,
60% for others.
3. No reduction permitted in Group A occupancies.

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Live Load Reduction Based on CBC 2001


INPUT DATA & DESIGN SUMMARY
MEMBER TYPE (0=Beam, 1=Column)

ROOF TRIBUTARY AREA SUPPORTED BY THE MEMBER


ROOF SLOPE
NUMBER OF FLOORS

500
Ar =
4 / 12
n =
1

TOTAL FLOOR TRIBUTARY AREA SUPPORTED BY THE MEMBER


FLOOR LIVE LOAD (CBC Table 16-A, or Table 16A-A)
DSA or OSHPD PROJECT ? (0=No, 1=Yes)

Af =
L =

700
100
0

ft

psf
No

UNIFORM
12.64
psf
53.35
psf

THE MINIMUM ROOF LIVE LOAD


THE MINIMUM FLOOR LIVE LOAD
TOTAL LOAD SUPPORTED BY THE COLUMN

Column
2
ft , (if no roof, input 0.)

6.32
37.34
43.66

kips
kips
kips

Note: Live loads are horizontal projected loads.

ANALYSIS
MINIMUM ROOF LIVE LOAD (CBC Table 16-C)
METHOD
ROOF SLOPE
[0~4) / 12
[4~12) / 12
[12~over) / 12

[ 0 ~ 200]
20
16
12

METHOD 1
TRIBUTARY AREA
( 200 ~ 600]
16
14
12
14

MINIMUM L r

METHOD 2
UNIFORM

( 600 ~ over)
12
12
12

L r (psf)
20
16
12
16

psf

REDUCTION

MAXIMUM

r
0.08
0.06
0
0.06

R (%)
40
25
0
25

12.64

psf

MINIMUM FLOOR LIVE LOAD BY TRIBUTARY AREA METHOD (CBC 1607.5)


L = (100 psf ) x (100 - R) / 100 =
60.00
psf
Where
r =
0.08
R =

r ( A f - 150 ) =

40.0

<==

note: 1. For storage loads exceeding 100 psf, no reduction


shall be made, except that design live loads on columns
may be reduced 20 percent.
2. Max reduction ,R, 40% for one level only, 60% for others.

<==

note: 1. This method Not adopted by DSA or OSHPD.

MINIMUM FLOOR LIVE LOAD BY INFLUENCE AREA METHOD (CBC 1607.6)


L = L0 [ 0.25 + 15 / (A I)
Where

0.5

]=

53.35

L0 =

100

psf

AI=

2800

ft

psf

2. Min reduced ,L, 50% for one level only, 40% for others.

__
Page 462 of 533
524

PROJECT :
CLIENT :
JOB NO. :

DATE :

Flexible Diaphragm with an Opening Analysis


INPUT DATA
Fp =

LATERAL DIAPHRAGM FORCE :


DIMENSIONS:

380

plf

X1 =

72

ft , X2 =

24

ft , X3 =

16

ft

Y1 =

20

ft , Y2 =

20

ft , Y3 =

20

ft

DESIGN SUMMARY
THE MAXIMUM STRAP FORCE, T = C =

4.66

THE MAXIMUM SHEAR STRESS,

vx=

kips
466

plf

vy=

480

plf

ANALYSIS

__
Page 463 of 533
524

PAGE :
DESIGN BY :
REVIEW BY :

(cont'd)
21.280

kips

a = X1 + 0.5 X2 =

84.00

ft

b = 0.5 Y2 + Y3 =

30.00

ft

Y = Y1 + Y2 + Y3 =

60.00

ft

w = Fp b / Y =

190.0

plf

M = a VL - 0.5 Fpx a =

446.9

ft-k, total moment at middle opening

F2 = M / Y =

7448

lbf

VL =

REACTIONS :

HATCHED AREA :

F5 = ( F2 b - 0.5 w a2 ) / a =

VR =

-5320

kips

F9 = F2 =

21.280

kips

V = b VL / Y =

7448

F15 = w a - V + F5 =

10.640

lbf
0

kips

X (ft)

Y (ft)

vx (plf)

vy (plf)

NO.

FORCE (lbf)

NO.

72.00

20.00

138

480

F1

9956

F15

12.00

20.00

209

266

F2

7448

F16

INDIVIDUAL PANEL

FORCE (lbf)

12.00

20.00

323

380

F3

3572

F17

-2512

16.00

20.00

223

299

F4

3040

F18

-1034
-4655

72.00

10.00

103

103

F5

-5320

F19

16.00

10.00

466

466

F6

7600

F20

1108

72.00

10.00

103

103

F7

2508

F21

-2508

16.00

10.00

466

466

F8

-3876

F22

3876

72.00

20.00

138

480

F9

7448

F23

3040

10

12.00

20.00

209

266

F10

7448

F24

5320

11

12.00

20.00

323

380

F11

2512

F25

7600

12

16.00

20.00

223

299

F12

1034

F26

9956

F13

4655

F27

3572

F14

-1108

Technical References:
1. Kelly E. Cobeen, MS, SE: "Structural Engineering Review Workshop", BYA publications, 2005.
2. Doug Thompson, SE: "Guide to Design of Diaphragm", SEAOSC/NCSEA Seminar, 11-7-2009.

__
Page 464 of 533
524

kips

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Formulas of Moment Resisting Frame at Bottom Fixed Condition


INPUT DATA & DESIGN SUMMARY
W16X26
BEAM SECTION
ORIENTATION (x-x, y-y)
COLUMN SECTION
W10X30
ORIENTATION (x-x, y-y)

301

in

x-x

W Shape
, (strong axis bending)

170

in

x-x

W Shape
, (strong axis bending)

BEAM LENGTH BETWEEN COL. CENTERS


STORY HEIGHT

L=
h=

1.8
w=
10.2
kips

GRAVITY LOAD
HA = HD =

30
14

ft
ft

klf
MB = MC =

95.5

ft-kips

Mmax =

107.0

ft-kips

VA = VD =

27.0

kips

MA = MD =

47.8

ft-kips

LATERAL LOAD
HA = HD =

7.5

kips

MB = MC =

43.7

ft-kips

VA = VD =

2.9

kips

H =

0.90

in

MA = MD =

61.3

ft-kips

KH =

16.6

kips / in

15

P=

kips

(KH is frame stiffness.)

GRAVITY ANALYSIS

h
=
n = Ib
Ic L
HA= HD =

M max =

V A =V D =

0.826

wL 2
=
4h ( 2 + n )

w L 2 ( 2 + 3n )
=
24 ( 2 + n )

wL
=
2

27.0

kips

10.2

kips

MA=MD=

wL
=
12 ( 2 + n )

47.8

ft-kips

107.0

ft-kips

MB = MC =

wL 2
=
6 (2 + n)

95.5

ft-kips

LATERAL ANALYSIS

a=h

3n
=
6n + 1

V A =V D =

E=

5.83

3nPh
=
L (1 + 6n )

b=h

ft

2.9

3n + 1
=
6n + 1

kips

29000 ksi

3
a
L
P b + a2
+
Ic
Ic
2I b
=
6E

8.17

HA= HD=

ft

MA=MD=

Ph (1 + 3n )
=
2 (1 + 6n )

61.3

ft-kips

MB = MC =

3nPh
=
2 (1 + 6n )

43.7

ft-kips

__
0.90

in

KH =

Page 465 of 533


524

16.6

kips / in

P
=
2

7.5

kips

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Formulas of Moment Resisting Frame at Bottom Pinned Condition


INPUT DATA & DESIGN SUMMARY
W16X26
BEAM SECTION
ORIENTATION (x-x, y-y)
COLUMN SECTION
W10X33
ORIENTATION (x-x, y-y)

301

in

x-x

W Shape
, (strong axis bending)

171

in

x-x

W Shape
, (strong axis bending)

BEAM LENGTH BETWEEN COL. CENTERS


STORY HEIGHT

GRAVITY LOAD
HA = HD =

1.8
w=
2.4
kips

VA = VD =

18.0

LATERAL LOAD
HA = HD =

7.5

VA = VD =

10.5

L=
h=

20
14

ft
ft

klf
MB = MC =

32.9

ft-kips

Mmax =

57.1

ft-kips

kips

MB = MC =

105.0

ft-kips

kips

H =

3.36

in

KH =

4.5

kips / in

kips

15

P=

kips

(KH is frame stiffness.)

GRAVITY ANALYSIS

h
=
n = Ib
Ic L
HA= HD =

M max =

V A =V D =

1.232

wL 2
=
4h ( 3 + 2n )

2.4

kips

57.1

ft-kips

P
=
2

7.5

kips

Ph
=
L

10.5

kips

P h 3 (1 + 2n )
=
12nE I c

3.36

in

w L 2 ( 2n + 1)
=
8 ( 2n + 3 )

wL
=
2

18.0

MB = MC =

kips

wL
=
4 ( 3 + 2n )

32.9

ft-kips

105.0

ft-kips

LATERAL ANALYSIS

HA= HD=

V A =V D =

H =

E=

29000

MB = MC =

ksi

Ph
=
2

KH =

P
H

4.5

__
Page 466 of 533
524

kips / in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Formulas of Concentrically Braced Frame


INPUT DATA & DESIGN SUMMARY
BRACE SECTION
HSS6X6X1/2

Tube

BEAM LENGTH BETWEEN COL. CENTERS


STORY HEIGHT

GRAVITY LOAD
HA = HD =

1.8
w=
18.1
kips

L=
h=

30
14

282460 kips

ft
ft

klf
MBE = MEC =

28.5

ft-kips

VA = VD =

27.0

kips

ME =

50.6

ft-kips

NAE = NDE =

24.7

kips

NAB = NDC =

10.1

kips

LATERAL LOAD
HA = HD =

7.5

kips

- NAE = NDE =

10.3

kips

VA = VD =

7.0

kips

- NAB = NDC =

0.0

kips

H =

0.01

in

KH =

1226.2

15

P=

kips / in ,

kips

(KH is frame stiffness.)

GRAVITY ANALYSIS (Neglected axial deformations.)

= tan 1

h
=
0.5 L

43.03

HA= HD=

5wL
=
16 tan

18.1

kips

5wL
=
16sin

24.7

kips

N AE = N DE =

wL
=
2

27.0

kips

9wL 2
=
512

28.5

ft-kips

50.6

ft-kips

7.0

kips

V A =V D =

M BE = M EC =

wL 2
=
32

LATERAL ANALYSIS

HA= HD=

P
=
2

N AE = N DE =

H =

7.5

P
=
2 cos

PL
=
4 EAcos 3

V A =V D =

kips

10.3

kips

0.01

in

KH =

Ph
=
L

P
H

1226.2

__
Page 467 of 533
524

kips / in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Formulas of Eccentrically Braced Frame


INPUT DATA & DESIGN SUMMARY
HSS6X6X1/2
BRACE SECTION

Tube

W16X26
BEAM SECTION
ORIENTATION (x-x, y-y)

W Shape
, (strong axis bending)

x-x

BEAM LENGTH BETWEEN COL. CENTERS


STORY HEIGHT
LINK LENGTH

1.8
w=
16.0
kips

GRAVITY LOAD
HA = HD =

L=
h=
e=

30
14
4

282460 kips
2
8729000 kips-in

ft
ft
ft

klf
MBE = MFC =

25.8

ft-kips

VA = VD =

27.0

kips

ME = MF =

24.5

ft-kips

NAE = NDF =

23.5

kips

NAB = NDC =

9.8

kips

LATERAL LOAD
HA = HD =

7.5

kips

- NAE = NDF =

11.0

kips

ME = MF =

14.0

ft-kips

- NAB = NDC =

-1.1

kips

QEF = VA = VD =

7.0

kips

H =

0.04

in

KH =

384.5

kips / in

15

P=

kips

(QEF is link shear force.)

(KH is frame stiffness.)

GRAVITY ANALYSIS (Neglected axial deformations.)

= tan 1

h
=
0.5 L 0.5e
wL
=
2

V A =V D =

ME=MF =

27.0

kips

HA= HD =

23.5

kips

M BE = M FC =

47.12

24.5

ft-kips , (by moment distribution procedure.)

2
2
M E + w (L e ) =
h
8h

16.0

kips

w( L e ) M E

=
32
2

25.8

ft-kips

HA =
N AE = N DF =
cos
LATERAL ANALYSIS

HA= HD=

P
=
2

7.5

N AE = N DF =

P
=
2 cos

H =

Ph
2 EAcos sin
2

Q EF = V A = V D =

kips

11.0

P h 2e 2
=
12 EIL

ME=MF =

kips

0.04

Ph
=
L

Peh
=
2L

7.0

kips

14.0

ft-kips

KH =

in

__
Page 468 of 533
524

P
H

384.5 kips / in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Rotation Analysis of Rigid Diaphragm Based on IBC 2009 / CBC 2010


INPUT DATA & DESIGN SUMMARY
DIAPHRAGM FORCES

Fpx =

1548.3

kips

Fpy =

1548.3

kips

DIAPHRAGM EDGE COORDINATES


Start Point

LATERAL FRAME LOCATION, RELATIVE RIGIDITY, & FRAME LINE FORCES


End Point

Frame

Start Point

End Point

Relative

Frame F (kips)

Relative

X (ft)

Y (ft)

X (ft)

Y (ft)

Number

X (ft)

Y (ft)

X (ft)

Y (ft)

@ Fpx

@ Fpy

xe (in)

0
0
30

0
90
90

0
30
30

90
90
125

1
2
3

30
160
270

0
0
0

30
160
270

90
120
90

1007.3
1087
1012.8

157.7
8.6
149.0

607.8
543.9
544.0

0.60
0.50
0.54

30

125

80

125

180

240

739.1

336.8

48.2

0.46

80
80
155
155

125
150
150
125

80
155
155
270

150
150
125
125

5
6
7
8

60
60
180
60

30.5
90
90
120

120
120
240
90

30.5
90
90
120

737.5
738.1
739.8
454.8

307.6
259.3
259.9
152.2

29.0
8.3
8.3
16.7

0.42
0.35
0.35
0.33

270

125

270

90

180

120

210

120

434.8

145.5

16.0

0.33

270
300
300
50

90
90
-10.67
-30

300
300
50

90
-10.67
-30

10

90

146

120

146

473.2

151.5

27.8

0.32

__
Page 469 of 533
524

(cont'd)

0
DIAPHRAGM
2
A = 43108.8 ft
cx

4
= 7.26E+08 ft

cy

= 1.09E+09 ft

MASS MOMENT OF INERTIA


2
2
Wt / 32.174 , kips-sec / ft ( Wt / 384 , kips-sec / in )
=
zc

30, 125

0, 90

8433

kips-ft-sec2

1214369

kips-in-sec )

CENTER OF MASS

CENTER OF RIGIDITY

Xcm =

147.2

ft

Xcg =

153.7

ft

Ycm =

53.6

ft

Ycg =

76.7

ft

80, 150

155, 150

80, 125

155, 125

270, 125

30, 90

270, 90

300, 90

CG
CM

0, 0
300, -10.67
50, -30

ANALYSIS
DETERMINE CENTER OF RIGIDITY
Ry

Xg

Yg

RxYg

1007.3

(ft)
30.0

(ft)
45.0

0.0

30219.0

1087.0

160.0

60.0

0.0

173920.0

Xcg = RyXg / Ry =

153.7

ft

Ycg = RxYg / Rx =

76.7

ft

Frame

Relative

Direction

Rx

Number
1

R
1007.3

90.0

R Cos

R Sin

0.0

1087

90.0

0.0

RyXg

1012.8

90.0

0.0

1012.8

270.0

45.0

0.0

273456.0

4
5
6
7
8
9
10

739.1
737.5
738.1
739.8
454.8
434.8
473.2

0.0
0.0
0.0
0.0
0.0
0.0
0.0

739.1
737.5
738.1
739.8
454.8
434.8
473.2

0.0
0.0
0.0
0.0
0.0
0.0
0.0

210.0
90.0
90.0
210.0
75.0
195.0
105.0

0.0
30.5
90.0
90.0
120.0
120.0
146.0

0.0
22493.8
66429.0
66582.0
54576.0
52176.0
69087.2

0.0
0.0
0.0
0.0
0.0
0.0
0.0

__
Page 470 of 533
524

(cont'd)

4317.3

DETERMINE ECCENTRICITY (ASCE 7-05 12.8.4.2)


Actual

Additional

3107.1

__

Total @ Fpx

CG - CM

5% & Ax

Case 1

ex (ft)

6.5

15.0

21.5

ey (ft)

23.1

9.0

331344.0 477595.0

Case 2

Total @ Fpy

Case 3

Case 4

32.1

14.1

-8.5

Page 471 of 533


524

Ax =

(ASCE 7-05 12.8.4.3)

(cont'd)
DETERMINE FRAME FORCES
Frame

rx

ry

Number
1
2
3
4
5
6
7
8
9
10

(ft)
-123.7
6.3
116.3
56.3
-63.7
-63.7
56.3
-78.7
41.3
-48.7

(ft)
-31.7
-16.7
-31.7
-76.7
-46.2
13.3
13.3
43.3
43.3
69.3

Ty
Case 1
33352.5
33352.5
33352.5
33352.5
33352.5
33352.5
33352.5
33352.5
33352.5
33352.5

rx2 Ry

Tx
Case 2
-13096.5
-13096.5
-13096.5
-13096.5
-13096.5
-13096.5
-13096.5
-13096.5
-13096.5
-13096.5

Case 3
49699.2
49699.2
49699.2
49699.2
49699.2
49699.2
49699.2
49699.2
49699.2
49699.2

Case 4
21829.8
21829.8
21829.8
21829.8
21829.8
21829.8
21829.8
21829.8
21829.8
21829.8

ry2 Rx

15416098
0
42994
0
13696262
0
0
4353483
0
1577419
0
129623
0
129921
0
850812
0
813397
0
2269394

__
Page 472 of 533
524

Fx (kips)
Case 1
157.7
-8.6
-149.0
336.8
307.6
252.3
252.9
138.2
132.1
128.2

Case 2
69.3
-3.8
-65.5
296.6
283.4
259.3
259.9
152.2
145.5
151.5

Fy (kips)
Case 3
607.8
535.9
404.7
48.2
29.0
-8.3
-8.3
-16.7
-16.0
-27.8

Case 4
460.4
543.9
544.0
-18.9
-11.4
3.3
3.3
6.6
6.3
10.9

(cont'd)

29155354 10124050
Fx = (Fpx Rx) / ( Rx) - [Tx (Rx ry +Ry rx) / ( ry Rx + rx Ry)]
2

2
Fy = (Fpy Ry) / ( Ry) - [Ty (Ry rx +Rx ry) / ( rx Ry + ry Rx)]
2

__
Page 473 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Flexible Diaphragm Analysis


DIAPHRAGM DESIGN FORCE FACTOR
DIAPHRAGM EDGE CORNER POINT
Corner
X
Y
Point
(ft)
(ft)
1
0
66.66
2
60.02
66.66
3
122.64
3.03
4
60.02
0
5
112.31
0
6
86.53
0
7
122.64
18.6
8
112.31
8.26
9
122.64
28.9
10
91.67
28.9
11
122.64
38.21
12
115.69
38.21
13
115.69
52.92
14
86.53
52.92
15
0
93.18
16
0
118.12
17
77.98
127.12
18
115.69
138.11
19
67.43
118.12
20
77.98
107.57
21
115.69
93.18
22
86.53
93.18
23
88.52
118.12
24
115.69
118.12
25
67.43
127.12
26
88.52
127.12
27
186.14
138.11
28
186.14
48.08
29
186.13
54.89
30
151.59
11.07
31
134.14
11.09
32
134.14
3.03
33
130
3.03
34
130
0
35
168.9
11.09
36
184.15
3.03
37
168.9
3.03
38
173.16
3.03
39
173.16
0
40
184.15
38.03
41
186.14
38.03
42
249.25
48.08
43
214.72
54.89
44
214.72
48.08
45
186.14
122.28
46
199.28
122.28
47
199.28
115.18
48
151.59
138.11
49
130
138.11
50
130
151.32
51
173.16
138.11
52
173.16
151.32
53
249.25
76.99
54
214.72
115.18
55
214.72
76.99

Fpx =

0.18

wpx , (ASCE 7-05 12.10.1.1 / CBC 01 1633.2.9)

DIAPHRAGM PANEL & SEISMIC DEAD LOAD


Panel
Corner
Corner
Corner
Corner
No.
1
2
3
4
1
15
16
19
20
2
25
17
20
19
3
20
17
26
23
4
1
15
22
2
5
4
2
22
6
6
14
22
21
13
7
6
14
13
10
8
10
13
12
11
9
10
9
7
8
10
3
11
12
18
11
49
50
52
51
12
34
33
32
31
13
30
48
27
41
14
45
46
47
54
15
29
43
44
28
16
55
53
42
44

Corner
5
23

Corner
6
24

8
9

48
35
40
43

SHEAR WALL (LATERAL FRAME) LOCATION


Start Point
End Point
SW
Drag to
Start (ft)
X (ft)
Y (ft)
X (ft)
Y (ft)
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

0
0
17
16.25
0
9
33
0
4.5
14.3
0
6.1
9
21
12.5
0
0
7
0
16.5
0
0
17.5
4
0
2
0
0
29
0
8.375
0
Tip:

Corner
7
21

Corner
8

30

31

32

37
36
29

38
37

39
35

Drag
Wall
Length
Length
69.87
9.25
85.29
9.25
10.17
25.6
15.4
122.87
3.26
133.94
3.26
17
28.1
11.1
169.13
3.26
183.92
3.26
0
31.8
14.8
138.9
11.32
169.13
11.32
15
61.5
30.2
69.87
52.55
88.9
52.55
9
28.0
19.0
107.33
52.55
115.99
52.55
0
17.7
8.7
219.22
48.31
243.81
48.31
5.5
63.1
24.6
9.2
77.01
19.85
77.01
4.5
15.2
10.7
28.87
77.01
47.73
77.01
14.3
37.7
18.9
76.29
77.01
115.99
77.01
72
126.0
39.7
214.45
76.76
224.33
76.76
6.1
16.0
9.9
230.76
76.76
249.02
76.76
0
24.4
18.3
18.25
115.92
45.53
115.92
21
57.3
27.3
87.44
115.89
98.29
115.89
17.67
49.5
10.9
199.05
114.96
214.45
114.96
0
27.9
15.4
68.44
124.89
87.44
124.89
0
19.0
19.0
115.99
137.81
144.84
137.81
7
35.9
28.9
158.6
137.81
185.84
137.81
0
34.2
27.2
130
150.09
135.13
150.09
16.5
21.6
5.1
168.03
150.09
173.16
150.09
0
21.6
5.1
9.2
77.01
9.2
84.85
31
38.8
7.8
69.87
9.25
69.87
15.93
17.5
24.2
6.7
69.87
51.03
69.87
66.37
6
38.8
15.3
68.45
77.01
68.44
111.98
13
52.0
35.0
95.45
9.25
113.88
27.69
2
28.1
26.1
115.99
29.8
115.99
137.81
0
110.0
108.0
122.87
3.26
122.87
18.59
19.75
35.1
15.3
183.92
3.26
183.92
38.31
28
63.1
35.1
185.84
94.74
185.84
137.81
0
72.1
43.1
214.45
48.31
214.45
60.25
8.375
20.3
11.9
214.45
76.76
214.45
114.96
0
46.6
38.2
249.02
48.31
249.02
76.76
0
28.5
28.5
Input the START point of each wall at left/bottom & END at right/top,
so easy to follow drag force locations.

__
Page 474 of 533
524

Drag fr
End (ft)

Corner
9

Seismic
DL (psf)
18
23
23
18
18
50
18
18
18
17
23
23
17
18
23
17

(cont'd)

P20
P17
P18
P19
50

52

P11
18

25

P2
19

16

17

26

P3

23

49

48

51

27

45

46

24
47

54

20

P1
15

22

21

P14
P4

55

P10

P6

53

P13

P16
14

13

28

P5

12

P8
10

43

29

11

P15

4041

P7
P9

7
31

30

35

__
8
5

33 32
34

P12

Page 475 of 533


524

37 38
39

36

44

42

(cont'd)

SW-19

SW-20

SW-17

SW-18

SW-16
SW-13

SW-29

SW-14

SW-15

SW-31

SW-24
SW-26

SW-21
SW-8

SW-9

SW-10

SW-23
SW-5

SW-11

SW-12
SW-32

SW-30

SW-6

SW-7

SW-28

SW-25
SW-22
SW-1

SW-27

SW-4

SW-2

SW-3

DIAPHRAGM PANEL LOAD AND CHORD FORCE


Panel

Area

No.
1
2

(ft2)

X (ft)

Y (ft)

2774
151

57.0
73.4

105.3
119.7

Centroid

Fpx
(kips)
9.0
0.6

Chord Force
L (ft)

T / C (k)

59.3
47.3

1.4
1.2

Note:
The Chord Force, T / C (kips), is from the equation,

150

82.6

119.7

0.6

47.3

1.2

T and/or C = Moment / Depth = (F px /Area ) L2 / 8 ,

4
5
6
7
8
9
10
11
12
13
14
15
16

1943
2119
1174
944
353
373
4464
570
411
4458
1817
195
998

37.0
74.0
101.1
96.8
109.8
110.3
134.1
151.6
151.5
168.9
200.0
200.4
232.0

80.7
40.3
73.1
25.5
36.3
21.5
75.3
144.7
5.3
73.3
86.8
51.5
62.5

6.3
6.9
10.6
3.1
1.1
1.2
13.7
2.4
1.7
13.6
5.9
0.8
3.1

59.3
43.3
45.9
34.0
34.0
34.0
70.5
43.2
61.0
70.5
67.0
28.3
34.8

1.4
0.8
2.4
0.5
0.5
0.5
1.9
1.0
1.9
1.9
1.8
0.4
0.5

where L should be actual maximum suppored span


and not larger than (3 A)0.5 since diaphragm ratio 3 max.

22894

__
80.5

Page 476 of 533


524

(cont'd)

TRIBUTARY DIAPHRAGM AREA TO HORIZONTAL (X DIRECTION) SHEAR WALL


Panel
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Number
13
16
16
8
10
10
5
6
25
17
19
4
18
15
7
11

Shear Wall
Top
Bottom
3%
70%
3%
100%
3%
100%
25%
20%
3%
20%
45%
35%
0%
15%
0%
50%
55%
55%
0%
30%
0%
25%
0%
100%
0%
30%
10%
50%
100%
0%
25%

Number
14

Shear Wall
Top
Bottom
3%
40%

9
5
6
6
25

35%
20%
25%
0%
55%

30%
28%
0%
45%
0%

10
20

25%
0%

10
7
12

Number

Shear Wall
Top
Bottom

Number

Shear Wall
Top
Bottom

28%

10%

25

45%

0%

25%
25%

4
17

25%
25%

0%
0%

2
18

5%
25%

0%
0%

25%
45%

25%
0%

25%

0%

5%

0%

0%

30%

50%

0%

Number

Shear Wall
Left

Right

26

30%

0%

%
116%
103%
103%
110%
109%
105%
105%
105%
110%
110%
100%
100%
110%
105%
100%
105%

TRIBUTARY DIAPHRAGM AREA TO VERTICAL (Y DIRECTION) SHEAR WALL


Panel
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Number
21
24
24
21
22
23
22
23
23
26
26
26
28
29
29
30

Shear Wall
Left
8%
0%
0%
5%
10%
0%
0%
0%
0%
0%
0%
0%
50%
0%
0%
0%

Right
30%
100%
50%
40%
40%
10%
25%
5%
8%
100%
55%
55%
0%
52%
50%
45%

Number
24

Shear Wall
Left
30%

Right
20%

Number
26

Shear Wall
Left
20%

Right
0%

26
24
23
24
23
25
25

55%
40%
10%
0%
0%
20%
30%

0%
18%
40%
15%
25%
0%
0%

26
26
25
26
26

10%
80%
15%
80%
80%

0%
0%
15%
0%
0%

29
28
29
31
30
31

55%
55%
55%
52%
55%
0%

0%
0%
0%
0%
0%
10%

32

50%

0%

__
Page 477 of 533
524

%
108%
100%
105%
103%
110%
105%
110%
105%
118%
100%
110%
110%
105%
104%
105%
105%

(cont'd)
DIAPHRAGM SHEAR STRESS AT EACH SIDE OF SHEAR WALL & DRAG FORCE AT TWO ENDS OF SHEAR WALL
Shear
Diaphragm
Shear Wall
Wall
Force
Stress
Shear (k)
Length (k)
Stress (plf)
Drag Force (k)
NO.
L/T
R/B
L/T
R/B
L/T
R/B
Start
End
(k)
(plf)
1
1.9
0.7
25.6
25.6
75
27
0.0
1.0
2.6
169
2
0.7
0.0
28.1
28.1
24
0
0.0
0.4
0.7
62
3
0.7
0.0
31.8
31.8
21
0
0.4
0.0
0.7
46
4
6.8
1.7
61.5
61.5
111
28
2.3
2.1
8.5
282
5
1.4
2.4
28.0
28.0
49
85
0.0
1.2
3.8
197
6
2.6
1.9
17.7
17.7
150
110
2.3
0.0
4.6
530
7
5.0
0.0
63.1
63.1
79
0
2.6
0.4
5.0
203
8
1.6
1.3
15.2
15.2
104
83
0.0
0.8
2.8
266
9
2.2
1.9
37.7
37.7
59
50
0.5
1.6
4.1
217
10
11.8
11.9
126.0
126.0
94
94
2.7
13.5
23.7
597
11
0.0
0.8
16.0
16.0
0
48
0.0
0.3
0.8
77
12
0.0
0.9
24.4
24.4
0
38
0.2
0.0
0.9
50
13
0.3
6.3
57.3
57.3
5
110
1.0
2.4
6.6
241
14
0.3
3.6
49.5
49.5
5
73
1.6
1.4
3.9
356
15
0.6
2.9
27.9
27.9
21
105
1.6
0.0
3.5
229
16
0.0
1.2
19.0
19.0
2
66
0.0
0.0
1.3
68
17
0.6
4.1
35.9
35.9
16
114
0.0
0.9
4.7
163
18
0.6
4.1
34.2
34.2
17
120
1.0
0.0
4.7
172
19
0.0
0.6
21.6
21.6
0
27
0.0
0.5
0.6
115
20
0.0
0.6
21.6
21.6
0
27
0.5
0.0
0.6
115
21
1.0
5.2
38.8
38.8
27
134
0.0
5.0
6.2
797
22
0.7
3.5
24.2
24.2
28
145
0.0
3.0
4.2
628
23
0.7
4.7
38.8
38.8
18
122
2.4
0.8
5.4
352
24
5.2
5.5
52.0
52.0
100
105
0.8
2.7
10.7
305
25
3.7
1.1
28.1
28.1
133
40
0.0
0.3
4.8
186
26
14.1
15.9
110.0
110.0
128
144
0.5
0.0
30.0
278
27
0.0
0.0
35.1
35.1
0
0
0.0
0.0
0.0
0
28
7.8
0.0
63.1
63.1
123
0
0.0
3.4
7.8
221
29
8.8
3.5
72.1
72.1
122
48
4.9
0.0
12.3
285
30
0.4
1.4
20.3
20.3
22
68
0.0
0.7
1.8
152
31
3.1
0.3
46.6
46.6
66
7
0.6
0.0
3.4
88
32
1.5
0.0
28.5
28.5
54
0
0.0
0.0
1.5
54
Max.
150
145
4.9
13.5
30.0
797

__
Page 478 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Open Structure (Solar Panels) Based on ASCE 7-2010
INPUT DATA
Exposure category (B, C or D)
Importance factor, 1.0 only, (Table 1.5-2)
Basic wind speed (ASCE 7-10 26.5.1)
Topographic factor (26.8 & Table 26.8-1)

Height of mean roof


Roof slope
Roof length
Roof horizontal projected width
Effective area of component / cladding

Iw
V
Kzt
h

=
=
=
=
=

L
B
A

=
=
=

C
1.00
136
1
10.5
0
16
11.33
10

mph
Flat
ft
: 12
ft
ft
2
ft

DESIGN SUMMARY
1. Main Wind-Force Resisting System
Max horizontal force / base shear from roof

Max vertical download force


Max vertical uplift force

=
=

Max moment at centroid of base from roof

2. Component and Cladding Elements


Max inward pressure
Max net outward pressure

0.00 kips
0.00 kips (eave & columns increasing)
0.00 kips
3.95 kips
4.48 kips

=
=

7.47 ft-kips
0.75 ft-kips (eave & columns increasing)
8.21 ft-kips

69 psf
103 psf

ANALYSIS
Velocity pressure

qh = 0.00256 Kh Kzt Kd V2
where:

34.21

psf

qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316)
Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1, pg 299)
Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250)
h = height of mean roof

0.85

=
=

0.85
10.50

ft

Main Wind-Force Resisting System (Sec. 27.4.3)

p = q h G CN
F = p Af
where:

G = gust effect factor. (Sec. 26.9)


= roof angle

=
=

<
Af = roof actual area.

=
=

CN = net force coefficients. (Fig. 27.4-4, page 267)


Check Fig. 27.4-4 limitation

0.00

CASE
A
p (psf)
F (kips)
B
p (psf)
F (kips)

h/B=

0.93

WIND TO BOTTOM, = 0o
CLEAR FLOW
OBSTRUCTED
CNW
CNL
CNW
CNL
1.20
0.30
-0.50
-1.20
34.89
8.72
-14.54
-34.89
3.16
0.79
-1.32
-3.16
-1.10
-0.10
-1.10
-0.60
-31.99
-2.91
-31.99
-17.45
-2.90
-0.26
-2.90
-1.58

within [0.25 , 1.0]

0.85
degree
0.00
45 deg. [Satisfactory]
ft2, windward
90.6

90.6

[Satisfactory]

WIND TO TOP, = 180o


CLEAR FLOW
OBSTRUCTED
CNW
CNL
CNW
CNL
1.20
0.30
-0.50
-1.20
34.89
8.72
-14.54
-34.89
3.16
0.79
-1.32
-3.16
-1.10
-0.10
-1.10
-0.60
-31.99
-2.91
-31.99
-17.45
-2.90
-0.26
-2.90
-1.58

ft2, leeward

(cont'd)

Horizontal force / base shear


Vertical download force
Vertical uplift force
Bending moment at centroid of base

H (kips)
V (kips)
V (kips)
M (ft-kips)

WIND TO BOTTOM, = 0o
WIND TO TOP, = 180o
CLEAR FLOW
OBSTRUCTED
CLEAR FLOW
OBSTRUCTED
CASE A CASE B CASE A CASE B CASE A CASE B CASE A CASE B
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
3.95
0.00
0.00
0.00
3.95
0.00
0.00
0.00
0.00
3.16
4.48
4.48
0.00
3.16
4.48
4.48
-6.719035 7.46559 -5.22592 3.732797 -6.719 7.465594 -5.2259 3.732797

Component and Cladding Elements (Sec. 30.8.2)

p = q h G CN
where:

CN = net force coefficients. (Fig. 30.8-1, page 351)


a = Max[ Min( 0.1L , 0.1B , 0.4h ) , 0.04L , 0.04B , 3ft ] , (Fig. 30.8-1, footnote 6)
For effective area, 10 sq.ft. as given
CLEAR WIND FLOW
ZONE 3
ZONE 2
CN
2.38
-3.24
1.80
-1.70
p (psf)
69.14
-94.24
52.34
-49.43

ZONE 1
1.20
-1.10
34.89
-31.99

3.0

ft

OBSTRUCTED WIND FLOW


ZONE 3
ZONE 2
ZONE 1
0.99
-3.53
0.80
-1.80
0.50
-1.20
28.86
-102.74
23.26
-52.34
14.54
-34.89

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Open Structure (Solar Panels) Based on ASCE 7-05 / IBC 2009 / CBC 2010

INPUT DATA
Exposure category (B, C or D)
Importance factor, pg 73, (0.87, 1.0 or 1.15)
Basic wind speed (3 sec. gust wind)
Topographic factor (Sec.6.5.7.2, pg 26 & 45)
Height of mean roof
Roof slope
Roof length
Roof horizontal projected width

=
=
=
=
=

L
B

=
=

C
0.87
90
1
35
3
100
60

Effective area of component / cladding

50

I
V
Kzt

Category I
mph
Flat
ft
: 12
ft
ft
2

ft

DESIGN SUMMARY
1. Main Wind-Force Resisting System
Max horizontal force / base shear from roof

=
+

Max vertical download force


Max vertical uplift force

=
=

Max moment at centroid of base from roof

111.99 kips
105.62 kips

2. Component and Cladding Elements


Max inward pressure
Max net outward pressure

28.00 kips
2.80 kips (eave & columns increasing)
30.80 kips

1819.76 ft-kips
181.98 ft-kips (eave & columns increasing)
2001.74 ft-kips

=
=

45 psf
55 psf

ANALYSIS
Velocity pressure

qh = 0.00256 Kh Kzt Kd V2 I
where:

15.49

psf

qh = velocity pressure at mean roof height, h. (Eq. 6-15, page 27)


Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-3, Case 1,pg 79)

1.01

Kd = wind directionality factor. (Tab. 6-4, for building, page 80)

=
=

0.85
35.00

ft

=
=

0.85
14.04

degree

h = height of mean roof


Main Wind-Force Resisting System (Sec. 6.5.13.2)

p = qh G CN
F = p Af
where:

G = gust effect factor. (Sec. 6.5.8, page 26).


= roof angle

<
Af = roof actual area.

45 deg. [Satisfactory]
2
3092.3 ft , windward

3092.3

CN = net force coefficients. (Fig. 6-18A, page 66)


Check Fig. 6-18A limitation

14.04

CASE
A
p (psf)
F (kips)
B
p (psf)
F (kips)

h/B=

0.58

WIND TO BOTTOM, = 0o
CLEAR FLOW
OBSTRUCTED
CNW
CNL
CNW
CNL
-0.86
-11.34
-35.07
-1.84
-24.17
-74.73

-1.26
-16.61
-51.35
0.00
0.00
0.00

-1.09
-14.31
-44.26
-2.05
-26.97
-83.40

-1.50
-19.75
-61.06
-0.63
-8.24
-25.47

within [0.25 , 1.0]

WIND TO TOP, = 180o


CLEAR FLOW
OBSTRUCTED
CNW
CNL
CNW
CNL
1.25
16.44
50.83
1.77
23.36
72.23

__
Page 479 of 533
524

[Satisfactory]

1.59
20.89
64.61
0.56
7.39
22.86

0.32
4.25
13.14
1.15
15.12
46.76

-1.11
-14.65
-45.30
-0.30
-3.95
-12.21

ft2, leeward

(cont'd)

Horizontal force / base shear


Vertical download force
Vertical uplift force
Bending moment at centroid of base

H (kips)
V (kips)
V (kips)
M (ft-kips)

o
WIND TO BOTTOM, = 0o
WIND TO TOP, = 180
CLEAR FLOW
OBSTRUCTED
CLEAR FLOW
OBSTRUCTED
CASE A CASE B CASE A CASE B CASE A CASE B CASE A CASE B
-20.96
-18.13
-25.54
-26.40
28.00
23.06
-7.80
8.38
0.00
0.00
0.00
0.00
111.99
92.25
0.00
33.51
83.84
72.50
102.18
105.62
0.00
0.00
31.20
0.00
481.8343 1789.84 634.176 1819.761 1193.04 43.75912 -1176.7 -618.538

Component and Cladding Elements (Sec. 6.5.13.3)

p = qh G CN
where:

CN = net force coefficients. (Fig. 6-19A, page 70)


a = Max[ Min( 0.1L , 0.1B , 0.4h ) , 0.04L , 0.04B , 3ft ] , (Fig. 6-19B, footnote 6)
For effective area, 50 sq.ft. as given
CLEAR WIND FLOW
ZONE 3
ZONE 2
CN
3.43
-3.71
2.66
-2.80
p (psf)
45.20
-48.90
35.04
-36.82

ZONE 1
1.77
-1.84
23.36
-24.17

ft

OBSTRUCTED WIND FLOW


ZONE 3
ZONE 2
ZONE 1
2.22
-4.16
1.72
-3.12
1.15
-2.05
29.26
-54.78
22.68
-41.11
15.12
-26.97

__
Page 480 of 533
524

6.0

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Open Structure Based on CBC 2001 / UBC 97


INPUT DATA
Exposure type (B, C or D)
Importance factor, (CBC Tab.16-K)
Basic wind speed (fastest mile wind)
Height of centroid of roof area
Roof slope
Roof length
Roof horizontal projected width

Iw
V
h

=
=
=
=

L
B

=
=

C
1.00
75
35
1
100
60

mph
ft
: 12
ft
ft

DESIGN SUMMARY
Max horizontal force / base shear from roof
Max vertical download force
Max vertical uplift force
Max bending moment at centroid of base from roof

=
=
=
=

39.14
0.00
78.56
1370.00

kips
kips
kips
ft-kips

ANALYSIS
Design pressures for wind force acting normal to the roof

F = Ce Cq qs Iw Af
where:

0.00

psf ) Af
psf ) Af

=
=

0.00

= ( 13.09
78.83
F = design wind load on open structural roof. (Sec. 1620).
= roof angle

kips, (inward)
kips, (outward)
=

4.76

degree

h = max top height for Ce calculation

37.49

ft

Ce = exposure and gust factor. (Tab. 16-G)

1.29

Cq = pressure coefficient. (Tab. 16-H, Item 1)

=
=

0.00
0.70

inward
outward

qs = wind stagnation pressure. (Tab. 16-F)

14.50

psf

Af = roof actual area.

6020.8

ft2

Horizontal force / base shear

H = F Sin

6.55 kips

Vertical download force

V = Finward Cos

0.00 kips

Vertical uplift force


Bending moment at centroid of base

V = Foutward Cos
M=Hh

=
=

78.56 kips
229.1 ft-kips

Design pressures for wind force acting to horizontal projected area

F = Ce Cq qs Iw Af
where:

74.82

psf ) Af

39.14

kips, (horizontal)

Cq = pressure coefficient. (Tab. 16-H, Item 5)

4.00

Af = horizontal projected area normal to the wind, included columns area.

523.2

Horizontal force / base shear


Vertical uplift / download force
Bending moment at centroid of base

H=F
V
M=Fh

__
Page 481 of 533
524

=
=
=

horizontal
ft2

39.14 kips
0.00 kips
1370.0 ft-kips

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Shade Open Structure Based on ASCE 7-2010


INPUT DATA
Exposure category (B, C or D)
Importance factor, 1.0 only, (Table 1.5-2)
Basic wind speed (ASCE 7-10 26.5.1)
Topographic factor (26.8 & Table 26.8-1)

Height of ridge
Roof slope
Roof length
Roof horizontal projected width
Effective area of component / cladding

Iw
V
Kzt
H

=
=
=
=
=

L
B
A

=
=
=

C
1.00
136
1
35
1
100
60
50

mph
Flat
ft
: 12
ft
ft
ft2

DESIGN SUMMARY
1. Main Wind-Force Resisting System
Max horizontal force / base shear from roof

Max vertical download force


Max vertical uplift force

=
=

Max bending moment, at centroid of base, from roof

2. Component and Cladding Elements


Max inward pressure
Max net outward pressure

8.40 kips
9.28 kips (eave & columns increasing)
17.68 kips
8.23 kips
261.33 kips

3371.27 ft-kips
208.80 ft-kips (eave & columns increasing)
3580.07 ft-kips

=
=

76 psf
146 psf

ANALYSIS
Velocity pressure

qh = 0.00256 Kh Kzt Kd V2
where:

40.35

psf

qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316)
Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1, pg 299)

1.00

Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250)


h = height of mean roof

=
=

0.85
33.75

ft

Main Wind-Force Resisting System (Sec. 27.4.3)

p = qh G CN
F = p Af
where:

G = gust effect factor. (Sec. 26.9)


= roof angle

=
=

<
Af = roof actual area.

0.85
degree
4.76
45 deg. [Satisfactory]
2
2107.3 ft , front / back

2
=
903.1 ft , each side
CN = net force coefficients. (Fig. 27.4-5, page 268 & Fig. 27.4-7, page 270, and CNS for two sides of sloped roof.)
Check Fig.27.4 limitation
h/L=
0.34 within [0.25 , 1.0]
[Satisfactory]
h/B=
0.56 within [0.25 , 1.0]
[Satisfactory]
CLEAR WIND FLOW
OBSTRUCTED WIND FLOW
CASE A
CASE B
CASE A
CASE B
CNW
CNL
CNS
CNW
CNL
CNS
CNW
CNL
CNS
CNW
CNL
CNS
1.10
-0.30
-0.80
0.20
-1.20
0.80
-1.60
-1.00
-1.20
-0.90
-1.70
0.50
p (psf)
37.73
-10.29
-27.44
6.86
-41.15
27.44
-54.87
-34.30
-41.15
-30.87
-58.30
17.15
F (kips)
79.50
-21.68
-24.78
14.45
-86.72
24.78
-115.63
-72.27
-37.17
-65.04 -122.86
15.49

Horizontal force / base shear


Vertical download force
Vertical uplift force
Bending moment at centroid of base

H (kips)
V (kips)
V (kips)
M (ft-kips)

CLEAR FLOW
OBSTRUCTED
CASE A CASE B CASE A CASE B
8.40
8.40
-3.60
4.80
8.23
0.00
0.00
0.00
0.00
22.64
261.33
156.39
-705.6
1516.7
3089.2
3371.3

(cont'd)
DETERMINE HORIZONTAL WIND LOAD OF COLUMNS AND EAVE
=
9.28 kips
Fcol & eave = pcol & eave Acol & eave
where:

pcol & eave = horizontal wind pressure

40.35

Acol & eave = horizontal projected area of columns and eave

230.0

6.0

Mcol & eave

208.8

psf
ft2

ft-kips

Component and Cladding Elements of Roof (Sec. 30.8.2)

p = qh G CN
where:

CN = net force coefficients. (Fig. 30.8-2, page 252)


a = Max[ Min( 0.1L , 0.1B , 0.4h ) , 0.04L , 0.04B , 3ft ] , (Fig. 30.8-2, footnote 6)
For effective area, 50 sq.ft. as given
CLEAR WIND FLOW
ZONE 3
ZONE 2
CN
2.20
-3.27
1.74
-1.76
p (psf)
75.57
-112.03
59.55
-60.48

ZONE 1
1.14
-1.16
38.98
-39.90

ft

OBSTRUCTED WIND FLOW


ZONE 3
ZONE 2
ZONE 1
0.97
-4.26
0.80
-2.31
0.50
-1.52
33.41
-146.16
27.44
-79.16
17.15
-52.05

<

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Shade Open Structure Based on ASCE 7-05 / IBC 2009
INPUT DATA
Exposure category (B, C or D)
Importance factor, pg 73, (0.87, 1.0 or 1.15)
Basic wind speed (3 sec. gust wind)
Topographic factor (Sec.6.5.7.2, pg 26 & 45)

Height of ridge
Roof slope
Roof length
Roof horizontal projected width
Effective area of component / cladding

I
V
Kzt
H

=
=
=
=
=

L
B
A

=
=
=

C
1.00
90
1
35
1
100
60
50

Category II
mph
Flat
ft
: 12
ft
ft
ft2

DESIGN SUMMARY
1. Main Wind-Force Resisting System
Max horizontal force / base shear from roof

Max vertical download force


Max vertical uplift force

=
=

Max bending moment, at centroid of base, from roof

2. Component and Cladding Elements


Max inward pressure
Max net outward pressure

3.68 kips
4.06 kips (eave & columns increasing)
7.74 kips
3.60 kips
114.45 kips

=
=

1476.39 ft-kips
91.44 ft-kips (eave & columns increasing)
1567.83 ft-kips
33 psf
64 psf

ANALYSIS
Velocity pressure

qh = 0.00256 Kh Kzt Kd V2 I
where:

17.67

psf

qh = velocity pressure at mean roof height, h. (Eq. 6-15, page 27)


Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-3, Case 1,pg 79)

1.00

Kd = wind directionality factor. (Tab. 6-4, for building, page 80)


h = height of mean roof

=
=

0.85
33.75

ft

Main Wind-Force Resisting System (Sec. 6.5.13.2)

p = qh G CN
F = p Af
where:

G = gust effect factor. (Sec. 6.5.8, page 26).


= roof angle

=
=

<
Af = roof actual area.

0.85
degree
4.76
45 deg. [Satisfactory]
2
2107.3 ft , front / back

2
=
903.1 ft , each side
CN = net force coefficients. (Fig. 6-18B, page 67 & Fig. 6-18D, page 69, and CNS for two sides of sloped roof.)
Check Fig. 6-18 limitation
h/L=
0.34 within [0.25 , 1.0]
[Satisfactory]
h/B=
0.56 within [0.25 , 1.0]
[Satisfactory]
CLEAR WIND FLOW
OBSTRUCTED WIND FLOW
CASE A
CASE B
CASE A
CASE B
CNW
CNL
CNS
CNW
CNL
CNS
CNW
CNL
CNS
CNW
CNL
CNS
1.10
-0.30
-0.80
0.20
-1.20
0.80
-1.60
-1.00
-1.20
-0.90
-1.70
0.50
p (psf)
16.52
-4.51
-12.02
3.00
-18.02
12.02
-24.03
-15.02
-18.02
-13.52
-25.53
7.51
F (kips)
34.81
-9.49
-10.85
6.33
-37.98
10.85
-50.64
-31.65
-16.28
-28.48
-53.80
6.78

Horizontal force / base shear


Vertical download force
Vertical uplift force
Bending moment at centroid of base

H (kips)
V (kips)
V (kips)
M (ft-kips)

CLEAR FLOW
OBSTRUCTED
CASE A CASE B CASE A CASE B
3.68
3.68
-1.58
2.10
3.60
0.00
0.00
0.00
0.00
9.91
114.45
68.49
-309.0
664.2
1352.9
1476.4

(cont'd)
DETERMINE HORIZONTAL WIND LOAD OF COLUMNS AND EAVE
=
4.06 kips
Fcol & eave = pcol & eave Acol & eave
where:

pcol & eave = horizontal wind pressure

17.67

Acol & eave = horizontal projected area of columns and eave

230.0

6.0

Mcol & eave

91.4

psf
ft2

ft-kips

Component and Cladding Elements of Roof (Sec. 6.5.13.3)

p = qh G CN
where:

CN = net force coefficients. (Fig. 6-19B, page 71)


a = Max[ Min( 0.1L , 0.1B , 0.4h ) , 0.04L , 0.04B , 3ft ] , (Fig. 6-19B, footnote 6)
For effective area, 50 sq.ft. as given
CLEAR WIND FLOW
ZONE 3
ZONE 2
CN
2.20
-3.27
1.74
-1.76
p (psf)
33.09
-49.06
26.08
-26.49

ZONE 1
1.14
-1.16
17.07
-17.48

ft

OBSTRUCTED WIND FLOW


ZONE 3
ZONE 2
ZONE 1
0.97
-4.26
0.80
-2.31
0.50
-1.52
14.63
-64.01
12.02
-34.67
7.51
-22.79

<

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Shade Open Structure Based on CBC 2001 / UBC 97
INPUT DATA
Exposure type (B, C or D)
Importance factor, (CBC Tab.16-K)
Basic wind speed (fastest mile wind)
Height of ridge
Roof slope
Roof length
Roof horizontal projected width

Iw
V
h

=
=
=
=

L
B

=
=

C
1.00
75
35
4
100
60

mph
ft
: 12
ft
ft

DESIGN SUMMARY
Max horizontal force / base shear
Max vertical download force
Max vertical uplift force
Max bending moment at centroid of base

=
=
=
=

54.14
0.00
85.08
1585.53

kips
kips
kips
ft-kips

ANALYSIS
Design pressures for wind force acting normal to the roof

F = Ce Cq qs Iw Af

where:

5.52

16.57

12.89

psf )
psf )
psf )
psf )

Af
Af
Af
Af

=
=
=
=

12.23

kips, (inward at front)

36.69

kips, (outward at front)

28.53

kips, (outward at back)

= ( 12.89
12.23
F = design wind load on open structural roof. (Sec. 1620).
= roof angle

kips, (outward at each side)


=

18.43

Ce = exposure and gust factor. (Tab. 16-G)

1.27

degree

Cq = pressure coefficient. (Tab. 16-H, Item 1)

=
=
=
=

0.30
0.90
0.70
0.70

inward at front
outward at front
outward at back
outward at sides

qs = wind stagnation pressure. (Tab. 16-F)

14.50

psf

Af = roof actual area.

2213.6

ft2, front / back

948.7

ft , each side

Horizontal force / base shear


Vertical download force
Vertical uplift force
Bending moment at centroid of base

H
V
V
M

=
=
=
=

12.89
0.00
85.08
377.5

kips
kips
kips
ft-kips

Design pressures for wind force acting to horizontal projected area

F = Ce Cq qs Iw Af
where:

73.66

psf ) Af

54.14

kips, (horizontal)

Cq = pressure coefficient. (Tab. 16-H, Item 5)

4.00

Af = horizontal projected area normal to the wind, included columns area.

735.0

Horizontal force / base shear


Vertical uplift / download force
Bending moment at centroid of base

H=F
V
M=Fh

__
Page 484 of 533
524

=
=
=

horizontal
ft2

54.14 kips
0.00 kips
1585.5 ft-kips

PROJECT :
CLIENT :
JOB NO. :

DATE :

PAGE :
DESIGN BY :
REVIEW BY :

Wind Load, on Roof Screen / Roof Equipment, Based on ASCE 7-2010


INPUT DATA & DESIGN SUMMARY
BASIC WIND VELOCITY

V =

136

EXPOSURE TYPE (B, C, D)

== >

mph

SCREEN TOP ELEVATION

H =

44

ft

HEIGHT OF STRUCTURE

h =

38

ft, (ASCE Fig. 29.5-1 note 3)

BUILDING WIDTH

B =

80

ft

BUILDING LENGTH

L =

150

ft

SCREEN VERTICAL SIZE

E =

ft

SCREEN HORIZONTAL SIZE

D =

20

ft, (ASCE Fig. 29.5-1)

VERTICAL PROJECTED AREA

Af =

80

ft

HORIZONTAL PROJECTED AREA

Ar =

40

ft

KZt =

Flat, (26.8 & Table 26.8-1)

TOPOGRAPHIC FACTOR
Out-of-plane load for screen design

2
2

P
Fh

=
=

80.1 psf, Horizontal


6.408 kips, Horizontal

Fv

2.53 kips, Vertical

WIND ANALYSIS
Out-of-plane wind force for screen design (ASCE 7-10, 29.5.1)

Fh

PAf

Where :

Fv

q hGC r A f

G Cr

K Zt K dV

Max{ Min[ 2 - Af / (B h) , 1.9] , 1.0} =

GC

1.90

Af

41.5 ft, centroid height of the screen

Bh

KZ

3040 ft2, building side area (ASCE 7-10 Eq. 29.5-2)


1.05 , (ASCE 7-10 Tab. 29.3-1)

Kd

0.85 , (ASCE 7-10 26.6)

q hGC r Ar

0.00256 K

K Zt K dV

GC

Ar

G Cr

Max{ Min[ 2 - Ar / (B L) , 1.5] , 1.0} =

BL

12000 ft2, building side area (ASCE 7-10 Eq. 29.5-3)

1.50

80.1 psf ) Af =

6.408 kips, Horizontal

, (ASCE 7-10 Eq. 29.5-2)

hc

P Ar

Where :

0.00256 K

63.2 psf ) Ar =

, (ASCE 7-10 Eq. 29.5-3)

2.53 kips, Vertical

PROJECT :
CLIENT :
JOB NO. :

DATE :

PAGE :
DESIGN BY :
REVIEW BY :

Wind Load on Roof Screen Based on IBC 2009 / ASCE 7-05


INPUT DATA & DESIGN SUMMARY
BASIC WIND VELOCITY

V =

85

EXPOSURE TYPE (B, C, D)

== >

mph
ft

SCREEN TOP ELEVATION

H =

44

HEIGHT OF STRUCTURE

h =

38

ft, (ASCE Fig. 6-21 note 3)

BUILDING WIDTH

B =

80

ft
(ASCE Tab. 6-1 & IBC Tab. 1604.5)

IMPORTANCE FACTOR

I =

SCREEN VERTICAL SIZE

E =

ft

SCREEN HORIZONTAL SIZE

D =

20

ft, (ASCE Fig. 6-21)

DESIGN MEMBER TRIBUTARY AREA

Af =

80

ft2

KZt =

Flat, (ASCE Eq.6-3)

TOPOGRAPHIC FACTOR
Out-of-plane load for screen design

P
F

=
=

35.0 psf
2.798 kips

WIND ANALYSIS
Out-of-plane wind force for screen design (ASCE 7-05, Eq.6-28)

F = P A f = f q ZGC f A f = f ( 0.00256 K Z K Zt K dV 2I ) GC f A f =
Where :

35.0 psf ) Af =

Max{ Min[ 2 - Af / (B h) , 1.9] , 1.0} =

f
hc

=
=

Bh
KZ
Kd

=
=
=

1.90
, (ASCE 6.5.15.1)
41.5 ft, centroid height of the screen
3040 ft2, building side area (ASCE 6.5.15.1)
1.05 , (ASCE Tab. 6-3)
0.85 , (ASCE Tab. 6-4)

G
Cf

=
=

0.85 , (ASCE 6.5.8.1)


1.32 , (ASCE Fig. 6-21)

__
Page 485 of 533
524

2.798 kips

Daniel
Tian Li

PROJECT :
CLIENT :
JOB NO. :

DATE :

PAGE :
DESIGN BY :
REVIEW BY :

Wind Load on Roof Screen Based on CBC 2001 / UBC 97


INPUT DATA & DESIGN SUMMARY
SCREEN TOP HEIGHT
IMPORTANCE FACTOR

H
Iw

=
=

44
1

BASIC WIND VELOCITY


EXPOSURE TYPE (B, C, D)
MEMBER TRIBUTARY AREA
MEMBER AT CORNER ?

=
=
=

75
C
80
Yes

Out-of-plane load for screen design

TA

ft
(UBC Tab. 16-K)
mph
ft2

26.0 psf

WIND ANALYSIS
Out-of-plane wind force for screen design (UBC 97 Sec.1620)
P = Ce Cq qs Iw = =
26.0 psf
Ce
Where :
=
1.33
(UBC Tab.16-G)
Cq
=
1.34
(UBC Tab.16-H Item 2 parapet, Item 3 wall corner, & footnote 2)
1.5 at corner, 1.3 at non-corner, and reduced by [Cq - 0.2 + (100-TA)/450 ] for TA @ [10,100]
qs
=
14.50 psf ,
(UBC Tab.16-F)

__
Page 486 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Axial Capacity of 1 1/2" Type "B" Roof Deck Based on ICBO ER-2078P
INPUT DATA & DESIGN SUMMARY
DECK VERT. SPAN LENGTH
GAGE (22,20,18,16) ? =>
DEAD LOAD
LIVE LOAD
WALL ANCHORAGE LOAD, ASD

L
== >
DL
LL
FP

5
18
20
20
730

=
=
=

ft
GA

psf
psf
plf

THE DESIGN IS ADEQUATE.


ANALYSIS
PLB & HSB SECTION PROPERTIES (ER-2078P, Table 4, page 3)
GAGE

thk, in

I, in4/ft

+S, in3/ft

-S, in3/ft

Wt, psf

16

0.0598

0.377

0.411

0.417

3.5

18

0.0478

0.302

0.322

0.335

2.9

20

0.0359

0.216

0.235

0.248

2.3

22

0.0299

0.175

0.187

0.198

1.9

in2

A =
0.84
r = ( I / A)0.5 =

2E

Fe =

( kL / r ) 2

0.877

in

E =

29500

ksi

Fy =

38

ksi

c =

29.15 ksi, (AISI C4.1-1)

F y , for c > 1.5

c2

Fn =

0.60

Fy

Fe

1.14

<

Mn = S Fe =

9.39

ft-k / ft

Pn = A Fn =

27.31

klf

32.60 ksi

0.658 c F y , for c 1.5


2

CHECK DECK CAPACITY (AISI C 5.2.1, Page 87)


M = (DL + LL ) L2 / 8 =
c =
PE

0.13

P = FP =

ft-k / ft

b =

1.8

2EI

( KL )2

0.75cP
Pn

24.42

0.04

0.75 cP bM C m
+
=
Mn
Pn

Note:

1.5

=1

klf

<

0.15

0.060

<

0.73
1.67

cP
=
PE

,(0.75 from AISI A.4.1.2)

1.0

[Satisfactory]

Roof live load & wall anchorage lateral load may be non-concurrent.

Technical References:
1. AISI STANDARD, 2001 Edition. American Iron and Steel Institute.

__
Page 487 of 533
524

klf

0.95

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Seismic Analysis Based on 2012 IBC (Equivalent Lateral Force Procedure, ASCE 7-2010)
INPUT DATA

DESIGN SUMMARY

Typical floor height


Typical floor weight
Number of floors
Importance factor (ASCE 11.5.1)
Design spectral response
Mapped spectral response
The coefficient (ASCE Tab 12.8-2)
The coefficient(ASCE Tab. 12.2.1)

h=
wx =
n=

9
800
40

Ie =

1.25

ft
kips

Total base shear


V
=
=

0.07 W, (SD) =
0.05 W, (ASD) =

Seismic design category

SDS = 0.916 g

hn =

SD1 = 0.498 g

W = 32,000 k

S1 = 0.496 g
Ct =
R=

k =
wxh =
x =
k

0.02
5.5

Ta = Ct (hn) =

360.0
1.58

2,191 k, (SD)
1,565 k, (ASD)
D

ft
, (ASCE 12.8.3, page 91)

137,376,298
0.75 , (ASCE Tab 12.8-2)
1.65

Sec, (ASCE 12.8.2.1)

VERTICAL DISTRIBUTION OF LATERAL FORCES


Level

Level

No.

Name

40

Roof

Floor to floor
Height
ft

Height

Weight

hx
ft
360.0

wx
k
800

wxhxk

Cvx

Lateral force @ each level

8,570,835

0.062

Fx
k
136.7

351.0

800

8,235,486

0.060

131.4

9.00
39

40th
39th

342.0

38th

800

7,905,058

0.058

126.1

333.0

37th

800

7,579,605

0.055

120.9

324.0

36th

800

7,259,185

0.053

115.8

315.0

35th

800

6,943,854

0.051

110.8

306.0

34th

800

6,633,675

0.048

105.8

297.0

33th

800

6,328,712

0.046

100.9

288.0

32th

800

6,029,030

0.044

96.2

279.0

31th

800

5,734,699

0.042

91.5

270.0

30th

800

5,445,792

0.040

86.9

261.0

29th

800

5,162,383

0.038

82.3

252.0

28th

800

4,884,554

0.036

77.9

243.0

27th

800

4,612,387

0.034

73.6

234.0

26th

800

4,345,970

0.032

69.3

225.0

25th

800

4,085,396

0.030

65.2

216.0

24th

800

3,830,763

0.028

61.1

207.0

23th

800

3,582,175

0.026

57.1

198.0

22th

800

3,339,741

0.024

53.3

189.0

21th

800

3,103,579

0.023

49.5

180.0

20th

17,503

741.6

4,800

183

24,177

847.4

5,600

183

31,804

948.3

6,400

183

40,338

1,044.5

7,200

183

49,739

1,136.0

8,000

183

59,962

1,222.8

8,800

183

70,968

1,305.2

9,600

183

82,714

1,383.1 10,400

183

95,162

1,456.6 11,200

183

108,271

1,525.9 12,000

183

122,005

1,591.1 12,800

183

136,325

1,652.2 13,600

183

151,195

1,709.3 14,400

183

166,579

1,762.6 15,200

183

182,442

1,812.1 16,000

183

800

2,873,813

0.021

45.8

198,751

1,858.0 16,800

183

215,473

1,900.2 17,600

183

1,858.0
171.0

9.00

183

1,812.1

9.00
19

4,000

1,762.6

9.00
20

630.8

1,709.3

9.00
21

11,826

1,652.2

9.00
22

183

1,591.1

9.00
23

3,200

1,525.9

9.00
24

515.0

1,456.6

9.00
25

7,190

1,383.1

9.00
26

183

1,305.2

9.00
27

2,400

1,222.8

9.00
28

394.1

1,136.0

9.00
29

3,643

1,044.5

9.00
30

183

948.3

9.00
31

1,600

847.4

9.00
32

268.1

741.6

9.00
33

1,230

630.8

9.00
34

Fpx
k
183

515.0

9.00
35

W i
k
800

394.1

9.00
36

Fi
k
136.7

268.1

9.00
37

Diaphragm force

O. M.
k-ft

136.7

9.00
38

Vx
k

800

2,650,577

0.019

42.3
1,900.2

Level

Level

No.

Name

18

19th

Floor to floor
Height
ft

Height

Weight

hx
ft

wx
k

wxhxk

Cvx

Lateral force @ each level


Fx
k

162.0

800

2,434,015

0.018

38.8

9.00
17

18th

153.0

17th

800

2,224,281

0.016

35.5

144.0

16th

800

2,021,542

0.015

32.2

135.0

15th

800

1,825,982

0.013

29.1

126.0

14th

800

1,637,798

0.012

26.1

117.0

13th

800

1,457,210

0.011

23.2

108.0

12th

800

1,284,460

0.009

20.5

99.0

11th

800

1,119,820

0.008

17.9

90.0

10th

800

963,594

0.007

15.4

81.0

9th

800

816,129

0.006

13.0

72.0

8th

800

677,826

0.005

10.8

63.0

7th

800

549,156

0.004

8.8

54.0

6th

800

430,681

0.003

6.9

45.0

5th

800

323,094

0.002

5.2

36.0

4th

800

227,276

0.002

3.6

27.0

3rd

800

144,408

0.001

2.3

18.0

2nd

304,181

2,062.0 21,600

183

322,739

2,085.3 22,400

183

341,507

2,105.7 23,200

183

360,458

2,123.6 24,000

183

379,571

2,139.0 24,800

183

398,822

2,152.0 25,600

183

418,189

2,162.8 26,400

183

437,655

2,171.6 27,200

183

457,199

2,178.4 28,000

183

476,805

2,183.6 28,800

183

496,457

2,187.2 29,600

183

516,142

2,189.5 30,400

183

800

76,206

0.001

1.2

535,848

2,190.7 31,200

183

555,564

2,191.1 32,000

183

2,190.7
9.0

9.00
Ground

183

2,189.5

9.00
1

2,035.9 20,800

2,187.2

9.00
2

285,858

2,183.6

9.00
3

183

2,178.4

9.00
4

2,006.8 20,000

2,171.6

9.00
5

267,797

2,162.8

9.00
6

183

2,152.0

9.00
7

1,974.5 19,200

2,139.0

9.00
8

250,026

2,123.6

9.00
9

183

2,105.7

9.00
10

1,939.0 18,400

2,085.3

9.00
11

232,575

2,062.0

9.00
12

Fpx
k
(cont'd)

2,035.9

9.00
13

W i
k

2,006.8

9.00
14

Diaphragm force
Fi
k

1,974.5

9.00
15

O. M.
k-ft

1,939.0

9.00
16

Vx
k

800

25,552

0.000

0.4
2,191.1

0.0

575,284

PROJECT :

PAGE :

CLIENT :

DESIGN BY :

JOB NO. :

DATE :

REVIEW BY :

Four Story Seismic Analysis Based on ASCE 7-10


Determine Base Shear (Derived from ASCE 7-10 12.8)
V = MAX{ MIN [ SD1Ie / (RT) , SDS Ie / R ] , MAX(0.044SDSIe , 0.01) , 0.5S1 Ie / R } W

= MAX{ MIN[ 0.15W , 0.18W ] , 0.06W , 0.00W }


=
0.15
W, (SD)
=
0.11
W, (ASD) =
1454.89 kips
Where

(for S1 0.6 g only)

SDS =

0.96

(ASCE 7-10 Sec 11.4.4)

SD1 =

0.54

(ASCE 7-10 Sec 11.4.4)

S1 =

0.55

(ASCE 7-10 Sec 11.4.1)

R=

(ASCE 7-10 Tab 12.2-1)

Ie =

1.5

(ASCE 7-10 Tab 1.5-2)

Ct =

0.028

(0.028 for steel MRF, 0.016 for concrete MRF, & 0.03 steel EBF)

hn =

52.0

ft

0.8

(ASCE 7-10 Tab 12.8-2)

x=
x

T = Ct (hn) =

0.661

sec, (ASCE 7-10 Sec 12.8.2.1)

Calculate Vertical Distribution of Forces & Allowable Elastic Drift (ASCE 7-10, Sec 12.8.3 & 12.8.6)
Level
Roof
4TH
3RD
2ND

Where

Wx
120
3500
4050
5620
13290.0

hx
52
40
28
16

hx
71.4
53.8
36.6
20.0

Wxhx
8571
188278
148199
112349
457396

Fx , ASD (12.8-11)
27.3
( 0.23 Wx )
598.9 ( 0.17 Wx )
471.4 ( 0.12 Wx )
357.4 ( 0.06 Wx )
1454.9

xe,allowable, ASD
0.3
0.3
0.3
0.4

k = 1

for T <= 0.5

k = 0.5 T + 0.75

for T @ (0.5 , 2.5)

Cd =

5.5

,(ASCE 7-10 Tab 12.2-1)

k = 2

for T >= 2.5

a =

0.01

hsx, (ASCE 7-10 Tab 12.12-1,


& Sec 12.12)

xe,allowable, ASD = a I / (1.4 Cd), (ASCE 7-10 Sec 12.8.6)

Calculate Diaphragm Forces (ASCE 7-10, Sec 12.10.1.1)


Level
Roof
4TH
3RD
2ND

Where

Wx
120.0
3500.0
4050.0
5620.0
13290.0

Wx
120.0
3620.0
7670.0
13290.0

Fx
27.3
598.9
471.4
357.4
1454.9

Fmin = 0.2 SDS I W x / 1.5 , ASD


Fmax = 0.4 SDS I W x / 1.5 , ASD

Fx
27.3
626.1
1097.5
1454.9

Fpx , ASD, (12.10-1)


27.3
( 0.23 Wx )
672.0
( 0.19 Wx )
777.6
( 0.19 Wx )
1079.0
( 0.19 Wx )

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Method to Calculate Redundancy Factor, , Based on ASCE 7-2010


Redundancy Factor (ASCE 7-10 Sec 12.3.4)
= 1.3 ,

only for Seismic Design Categories D through F, and an individual element removed will be causing the remaining
structural to suffer a reduction of Story Strength of more than 35% or creating an extreme torsional irregularity.

= 1.0 ,

all other cases.

Note:

To verify Redundancy Factor 1.0, the relative Rigidity of each frame at calculation level have to be known, since the Code
Redundancy Provision Committee envisioned Story Strength as Rigidity, and SEAOC Seismology Committee endorsed
this interpretation (SEAOC Seismic Design Manual -1, page 72).

4231.4(3231.4+153.8)
= 8.4% 33%
4231.4

= 1.0

PROJECT :

PAGE :

CLIENT :

DESIGN BY :

JOB NO. :

DATE :

REVIEW BY :

Response Spectra Analysis Based on ASCE 7-10


INPUT DATA

ANALYSIS

SEISMIC DESIGN PARAMETER

SDS =

0.96

(ASCE 7-10 11.4.4)

Station

T (s)

SEISMIC DESIGN PARAMETER

SD1 =

0.545

(ASCE 7-10 11.4.4)

0.00

0.38

0.32

LONG-PERIOD TRANSITION PERIOD

TL =

(ASCE 7-10 11.4.5)

0.10

0.89

0.67

0.13

0.96

0.65

0.17

0.96

0.74

0.18

0.96

0.87

0.20

0.96

0.72

0.25

0.96

0.86

0.33

0.96

0.77

0.43

0.96

0.80

0.50

0.96

0.92

10

0.67

0.82

0.62

11

1.00

0.55

0.45

12

1.25

0.44

0.24

13

1.50

0.36

0.19

14

1.75

0.31

0.15

15

2.00

0.27

0.14

16

2.25

0.24

0.17

17

2.50

0.22

0.18

18
19

2.75
3.00

0.20
0.18

0.16
0.12

20

3.25

0.17

0.11

21

3.50

0.16

0.10

22

3.75

0.15

0.08

23

4.00

0.14

0.06

RESPONSE SPECTRA
1.20
1.00

Sa (g)

0.80
0.60
0.40
0.20
0.00
0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

Period T, Seconds

Sa(g) (IBC/CBC) A/g (El Centro)

STATIC ANALYSIS PERIOD (ASCE 7-10 12.8.2)


x

APPROXIMATE FOUNDATIONAL PERIOD

Ta = Ct (hn) =

0.799

sec, (ASCE 7-10 Sec 12.8.2.1)

Tb =

1.095

sec, (may from RISA, ETABS, RAM)

SUBSTANTIATED ANALYSIS PERIOD

T = Max[ Ta , Min( Tb , CuTa )] =


where Cu =

1.400

1.095

sec.

, (ASCE 7-10 Tab. 12.8-1)

SCALE FACTOR
BASE SHEAR BY ELASTIC DYNAMIC ANALYSIS (ASCE 7-10 12.9)
BASE SHEAR BY STATIC ANALYSIS (ASCE 7-10 12.8)

VDX =

3000

kips

VS =

735.09

kips

VDY =

3500

kips

RESPONSE MODIFICATION COEFFICIENT (ASCE 7 Tab 12.2-1)

R=

IMPORTANCE FACTOR

Ie =

1.5

SFX = VX / VD

= 0.245

== >

Yes

SFY = VY / VD

= 0.210

DSA/OSHPD PROJECT (CBC Chapter A) ?


VX = Max( 0.85 VS , VDX Ie / R ) =

624.83

kips, (ASCE 7-10 12.9.2 & 12.9.4)

VX = Max( 1.0 VS , VDX Ie / R ) =

735.09

kips, (ASCE 7-10 12.9.2 & CBC 1614A.1.9)

VY = Max( 0.85 VS , VDY Ie / R ) =

656.25

kips, (ASCE 7-10 12.9.2 & 12.9.4)

VY = Max( 1.0 VS , VDY I / R ) =

735.09

kips, (ASCE 7-10 12.9.2 & CBC 1614A.1.9)

Notes:
See following link for more information.
http://www.engineering-international.com/NonlinearGuide.pdf

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Low-rise Building, Based on ASCE 7-05 / IBC 2009 / CBC 2010
INPUT DATA
Exposure category (B, C or D)
Importance factor, pg 77, (0.87, 1.0 or 1.15)
Basic wind speed (IBC Tab 1609.3.1V3S)

I =
V =

C
1.00
85

Topographic factor (Sec.6.5.7.2, pg 26 & 45)

Kzt =

Flat

Building height to eave

he =

11

ft

Building height to ridge


Building length
Building width
Effective area of components (or Solar Panel area)

hr
L
B
A

=
=
=
=

18
100
50
28

ft
ft
ft
ft2

Category II
mph

DESIGN SUMMARY
Max horizontal force normal to building length, L, face
Max horizontal force normal to building length, B, face
Max total horizontal torsional load
Max total upward force

=
=
=
=

18.00
7.26
132.45
51.97

kips
kips
ft-kips
kips

ANALYSIS
Velocity pressure

qh = 0.00256 Kh Kzt Kd V2 I
where:

13.36

psf

qh = velocity pressure at mean roof height, h. (Eq. 6-15, page 27)


Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-3, Case 1,pg 79)

0.85

Kd = wind directionality factor. (Tab. 6-4, for building, page 80)

=
=

0.85
14.50

h = mean roof height

ft

< 60 ft, [Satisfactory]


< Min (L, B), [Satisfactory]
Design pressures for MWFRS

p = qh [(G Cpf )-(G Cpi )]


where:

pmin =

p = pressure in appropriate zone. (Eq. 6-18, page 28).

10

psf (Sec. 6.1.4.1 & 6.1.4.2)

G Cp f = product of gust effect factor and external pressure coefficient, see table below. (Fig. 6-10, page 53 & 54)
G Cp i = product of gust effect factor and internal pressure coefficient.(Fig. 6-5, Enclosed Building, page 47)
=
0.18
or
-0.18
a = width of edge strips, Fig 6-10, note 9, page 54, MAX[ MIN(0.1B, 0.1L, 0.4h), MIN(0.04B, 0.04L), 3] =
Net Pressures (psf), Basic Load Cases
Roof angle =
15.64
Surface

1
2
3
4
1E
2E
3E
4E
5
6

G Cp f

0.49
-0.69
-0.45
-0.39
0.74
-1.07
-0.64
-0.58
-0.45
-0.45

Net Pressure with

(+GCp i )

(-GCp i )

4.17
-11.63
-8.39
-7.61
7.55
-16.70
-11.00
-10.14
-8.42
-8.42

8.98
-6.82
-3.58
-2.80
12.36
-11.89
-6.19
-5.33
-3.61
-3.61

Roof angle = 0.00


G Cp f

0.40
-0.69
-0.37
-0.29
0.61
-1.07
-0.53
-0.43
-0.45
-0.45

Net Pressure with

(+GCp i )

(-GCp i )

2.94
-11.63
-7.35
-6.28
5.75
-16.70
-9.49
-8.15
-8.42
-8.42

7.75
-6.82
-2.54
-1.47
10.56
-11.89
-4.68
-3.34
-3.61
-3.61

Net Pressures (psf), Torsional Load Cases


Roof angle = 15.64
Surface

1T
2T
3T
4T
Surface

__
Page 493 of 533
524

5.00

1T
2T
3T
4T

G Cp f

Net Pressure with

(+GCp i ) (-GCp i )

0.49
1.04
-0.69
-2.91
-0.45
-2.10
-0.39
-1.90
Roof angle =
G Cp f

0.40
-0.69
-0.37
-0.29

2.25
-1.70
-0.90
-0.70
0.00

Net Pressure with

(+GCp i ) (-GCp i )
0.73
-2.91
-1.84
-1.57

1.94
-1.70
-0.63
-0.37

ft

Basic Load Cases in Transverse Direction


Surface

1
2
3
4
1E
2E
3E
4E

Min. wind
Sec. 6.1.4.1

Area

Basic Load Cases in Longitudinal Direction

Pressure (k) with

(ft2)

(+GCp i )

(-GCp i )

990
2337
2337
990
110
260
260
110
Horiz.
Vert.
Horiz.
Vert.

4.13
-27.16
-19.61
-7.53
0.83
-4.34
-2.86
-1.12
11.17
-51.97
18.00
-50.00

8.89
-15.92
-8.37
-2.77
1.36
-3.09
-1.61
-0.59
11.17
-27.92
18.00
-50.00

Surface

1
2
3
4
1E
2E
3E
4E

Min. wind
Sec. 6.1.4.1

Torsional Load Cases in Transverse Direction


Surface

Area

Pressure (k) with

(+GCp i )

(ft2)

Pressure (k) with

(ft2)

(+GCp i )

(-GCp i )

601
2077
2077
601
124
519
519
124
Horiz.
Vert.
Horiz.
Vert.

1.77
-24.15
-15.27
-3.77
0.71
-8.67
-4.93
-1.01
7.26
-51.05
7.25
-50.00

4.66
-14.15
-5.27
-0.88
1.31
-6.18
-2.43
-0.41
7.26
-26.99
7.25
-50.00

Torsional Load Cases in Longitudinal Direction

Torsion (ft-k)

41
-73
53
75
37
-53
35
50
-14
25
-18
-26

89
-43
23
28
61
-37
20
26
-31
15
-8
-10

132

132

Area

Surface

(-GCp i ) (+GCp i ) (-GCp i )

1
440
1.84
3.95
2
1038
-12.07
-7.08
3
1038
-8.72
-3.72
4
440
-3.35
-1.23
1E
110
0.83
1.36
2E
260
-4.34
-3.09
3E
260
-2.86
-1.61
4E
110
-1.12
-0.59
1T
550
0.57
1.24
2T
1298
-3.77
-2.21
3T
1298
-2.72
-1.16
4T
550
-1.05
-0.38
Total Horiz. Torsional Load, MT

Area

(ft2)

Pressure (k) with

Torsion (ft-k)

(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )

1
239
0.70
1.85
2
1558
-18.11
-10.62
3
1558
-11.45
-3.96
4
239
-1.50
-0.35
1E
124
0.71
1.31
2E
519
-8.67
-6.18
3E
519
-4.93
-2.43
4E
124
-1.01
-0.41
1T
363
0.27
0.70
2T
2077
-6.04
-3.54
3T
2077
-3.82
-1.32
4T
363
-0.57
-0.13
Total Horiz. Torsional Load, MT

5
122
-77
11
14
58
-33
20
-3
-81
51
-7

13
72
-27
3
26
42
-16
8
-8
-48
18
-2

80.5

80.5

Design pressures for components and cladding

p = qh[ (G Cp) - (G Cpi)]


where:

p = pressure on component. (Eq. 6-22, pg 28)


pmin =

10.00

psf (Sec. 6.1.4.2, pg 21)

G Cp = external pressure coefficient.


see table below. (Fig. 6-11, page 55~58)

Effective
Area (ft2)
Comp.

28

Comp. & Cladding


Pressure
( psf )

Note:

Zone 1
GCP
- GCP

0.41

-0.86

Zone 1

GCP

Zone 2
- GCP

GCP

Zone 3
- GCP

0.41

-1.48

0.41

-2.33

Zone 2

Zone 3

Zone 4
GCP
- GCP

0.92

-1.02

Zone 4

Zone 5
GCP
- GCP

0.92

-1.24

Zone 5

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

10.00

-13.83

10.00

-22.14

10.00

-33.56

14.71

-16.05

14.71

-19.00

If the effective area is roof Solar Panel area, the only zone 1, 2 , or 3 apply.

__
Page 494 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Building with h > 60 ft, Based on ASCE 7-05 / IBC 2009 / CBC 2010

INPUT DATA
Exposure category (B, C or D)
Importance factor (0.87, 1.0 or 1.15)
Basic wind speed (IBC Tab 1609.3.1V3S)

I =
V =

Topographic factor (Sec.6.5.7.2)

Kzt =

Building height to roof

H =

C
1.00
90

Category II, page 77


mph

1
157

Flat, page 26 & 45


ft

Parapet height
Building length
Building width
Natural frequency (Sec.6.2 & 6.5.8.2)

HP
L
B
n1

=
4
=
300
=
180
= 0.95541

Effective area of mullion

AM =

55

ft
ft
ft
Hz, (1 / T)
ft2

Effective area of panel

AP =

27

ft2

DESIGN SUMMARY
Max building horizontal force normal to building length, L, face
Max overturning moment at wind normal to building length, L, face
Max building horizontal force normal to building length, B, face
Max overturning moment at wind normal to building length, B, face
Max building upward force
Max building torsion force

=
=
=
=
=
=

1194.9
180021.1
636.0
159648.2
1334.7
40327.6

kips
ft - kips
kips
ft - kips
kips
ft - kips

ANALYSIS
Velocity pressures

qz = 0.00256 Kz Kzt Kd V2 I
where:

qz = velocity pressure at height, z. (Eq. 6-15, page 27)

pmin =

10

psf (Sec. 6.1.4.1 & 6.1.4.2)

Kz = velocity pressure exposure coefficient evaluated at height, z. (Tab. 6-3, Case 2, page 79)
Kd = wind directionality factor. (Tab. 6-4, for building, page 80)
z = height above ground

0.85

z (ft)
Kz

0 - 15

20

25

30

40

50

60

70

80

90

100

120

0.85

0.90

0.94

0.98

1.04

1.09

1.13

1.17

1.21

1.24

1.26

1.31

qz (psf)

14.98

15.86

16.57

17.27

18.33

19.21

19.92

20.62

21.33

21.86

22.21

23.09

z (ft)
Kz

140

160

161

161

161

161

161

161

161

161

1.36

1.39

1.39

1.39

1.39

1.39

1.39

1.39

1.39

1.39

qz (psf)

23.97

24.50

24.53

24.53

24.53

24.53

24.53

24.53

24.53

24.53

0.18

or

Design pressures for MWFRS

p = q G Cp - qh (G Cpi)
where:

p = pressure on surface for rigid building with all h. (Eq. 6-17, page 28).
q = qz for windward wall at height z above the ground, see table above.
G Cp i = internal pressure coefficient. (Fig. 6-5, Enclosed Building, page 47)

-0.18

qh = qz value at mean roof height, h, for leeward wall, side walls, and roof.
Cp = external pressure coefficient, see right down tables.
G = gust effect factor (Sec. 6.5.8.1 & 6.5.8.2, Page 26)

1 + 1.7 I g 2 Q 2 + g 2 R 2
z Q
R
0.925
, for n1 < 1.0

1 + 1.7 g v I z

G=

1 + 1.7 g Q I zQ
0.925
,
for
n

1 1.0
1 + 1.7 g v I z

= 0.854

Iz =

0.17

z =

94.2

Q=

0.84

z min =

15

gQ =

3.4

617

c=

0.2

gR =

4.18

Lz =
=

Rh =

0.135

RB =

0.119

RL =

0.023

N1 =

5.84

Rn =

0.046

R=

0.090

h=

157

gv =

3.4

Vz =

100.8

Fig. 6-6 fo < 10o, page 48


Roof

h/B
0.89
0.89
0.89
0.89
h/L

Distance
80.5
161
180
180
Distance

Cp
-1.01
-0.74
-0.66

To B Face

0.54

80.5

-0.91

To B Face

0.54
0.54
0.54

161
300
300

-0.89
-0.51

To L Face
To L Face
To L Face
To L Face

Roof

q G Cp Figure for Gable, Hip Roof, page 48


Fig. 6-6, page 48
Wall
Windward Wall
Leeward Wall
Leeward Wall
Side Wall

Direction
All
To L Dir
To B Dir
All

L/B
All
0.60
1.67
All

Cp
0.80
-0.50
-0.37
-0.70

To B Face
To B Face

Cp

0.05

(cont'd)
Hence, MWFRS Net Pressures are given by following tables (Sec. 6.5.12.2.1, Page 28)
P (psf) with

Windward Wall

Surface

P (psf) with

z (ft)

GCPi

- GCPi

Surface

z (ft)

GCPi

- GCPi

0 - 15
20
25
30
40

5.81
6.42
6.90
7.38
8.10

14.65
15.25
15.73
16.21
16.93

Side Wall

All

-19.08

-10.24

Surface

z (ft)

50
60
70
80
90

8.70
9.18
9.67
10.15
10.51

17.54
18.02
18.50
18.98
19.34

Leeward

All

100
120
140
160
161

10.75
11.35
11.95
12.31
12.34

19.58
20.18
20.79
21.15
21.17

Normal to L Face

Normal to L Face

Surface

Dist. (ft)

0 - 80.5
161
180

Roof

P (psf) with
GCPi
- GCPi
-14.89

-6.06

P (psf) with
GCPi
- GCPi
-25.58
-19.96
-18.19

-16.75
-11.13
-9.36

Normal to B Face

P (psf) with

Surface

z (ft)

GCPi

- GCPi

Leeward

All

-12.10

-3.26

Normal to B Face

Surface

Roof

Dist. (ft)

0 - 80.5
161
300

P (psf) with
GCPi
- GCPi
-23.48
-22.96
-15.20

-14.65
-14.13
-6.36

Figure 6-9, page 52


Base Forces

Normal to L Face
Case 1
Case 2

Normal to B Face
Case 1
Case 2

Wind with Angle


Case 3
Case 4

ASCE-7

VBase

(kips)

1195

896

636

477

1373

762

MBase

(ft - kips)

180021

135016

159648

119736

254752

135466

Fig. 6-9

MT

(ft - kips)

40328

12879

39941

Page 52

FUpward (kips)

965

724

815

611

1335

711

(kips)

483

483

290

290

580

563

Min. wind

FUp,min (kips)

540

540

540

540

540

540

Sec. 6.1.4.1

Vmin

Design pressures for components and cladding

p = q (G Cp) - qi (G Cpi)
where:

p = pressure on component for building with h > 60 ft. (Eq. 6-23, page 29).
pmin =

10.00

psf (Sec. 6.1.4.2, pg 21)

q = qz for windward wall at height z above the ground, see table above.
qh = qz value at mean roof height, h, for leeward wall, side walls, and roof.
G Cp i = internal pressure coefficient. (Fig. 6-5) =
0.18
or
-0.18
a = Zone width = MAX[ MIN(0.1B, 0.1L), 3] =
18.0 ft, (Fig 6-17 note 8, pg 65)
G Cp = external pressure coefficient. (Fig. 6-17, page 65)
Wall
Comp.

Actual Effective
Area ( ft2 )

GCP

- GCP

GCP

- GCP

55
27

0.81
0.87

-0.84
-0.88

0.81
0.87

-1.55
-1.73

Mullion
Panel

z (ft)

0 - 15
20
25
30
40
50
60
70
80
90
100
120
140
160
161

Zone 4

Zone 5

Mullion Pressure (psf)


Zone 4
Zone 5

Panel Pressure (psf)


Zone 4
Zone 5

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

14.77
15.64
16.33
17.03
18.07
18.94
19.63
20.33
21.02
21.54
21.89
22.76
23.63
24.15
24.18

-24.96
-24.96
-24.96
-24.96
-24.96
-24.96
-24.96
-24.96
-24.96
-24.96
-24.96
-24.96
-24.96
-24.96
-24.96

14.77
16.69
17.43
18.17
19.28
20.21
20.95
21.69
22.44
22.99
23.36
24.29
25.22
25.77
25.81

-42.41
-42.41
-42.41
-42.41
-42.41
-42.41
-42.41
-42.41
-42.41
-42.41
-42.41
-42.41
-42.41
-42.41
-42.41

15.76
16.69
17.43
18.17
19.28
20.21
20.95
21.69
22.44
22.99
23.36
24.29
25.22
25.77
25.81

-26.04
-26.04
-26.04
-26.04
-26.04
-26.04
-26.04
-26.04
-26.04
-26.04
-26.04
-26.04
-26.04
-26.04
-26.04

15.76
16.69
17.43
18.17
19.28
20.21
20.95
21.69
22.44
22.99
23.36
24.29
25.22
25.77
25.81

-46.75
-46.75
-46.75
-46.75
-46.75
-46.75
-46.75
-46.75
-46.75
-46.75
-46.75
-46.75
-46.75
-46.75
-46.75

cont'd

Components and Cladding

Roof

Components and Cladding

Roof

Effective
Area ( ft2 )

Zone 1

Zone 2

Zone 3

- GCP

- GCP

- GCP

-1.40

-2.30

-3.20

10

-1.40

-2.30

-3.20

59

-1.17

-1.98

-2.79

108

-1.10

-1.87

-2.65

157

-1.05

-1.81

-2.57

206

-1.01

-1.76

-2.50

255

-0.99

-1.72

-2.45

304

-0.96

-1.69

-2.41

353

-0.94

-1.66

-2.38

402

-0.93

-1.64

-2.35

451

-0.91

-1.62

-2.32

500

-0.90

-1.60

-2.30

38016

-0.90

-1.60

-2.30

38016

4104

972

Effective
Area ( ft2 )

Net Pressure (psf)


Zone 1

Zone 2

Zone 3

-38.77

-60.85

-82.93

10

-38.77

-60.85

-82.93

59

-33.20

-53.05

-72.91

108

-31.30

-50.40

-69.50

157

-30.13

-48.76

-67.38

206

-29.28

-47.56

-65.85

255

-28.61

-46.63

-64.65

304

-28.06

-45.86

-63.65

353

-27.59

-45.20

-62.81

402

-27.18

-44.63

-62.08

451

-26.82

-44.12

-61.43

500

-26.50

-43.67

-60.85

38016

-26.50

-43.67

-60.85

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Relative Rigidity Determination for Shear Wall with New Opening


INPUT DATA & DESIGN SUMMARY
20
ft
DIMENSIONS
L=
H=
20
ft
OPENING

LOCATION

b=
h=

5
10

ft
ft

L1 =

10

ft

H1 =

ft
R = 100%

ONE STORY ?
Yes
(Cantilever Wall with Fixed Base Only)

Not Apply

R = 82%

The new opening reduced the lateral load capacity by 18%.

ANALYSIS (Per California SE Exam 1984)


R=1/
,
= Flexure + Shear
Where

Flexure = 4 H3 / (E L3 t) , for cantilever


Flexure = H3 / (E L3 t) , for fixed at top and base
Shear = 1.2 H / (G A) = 3 H / (E L t)

Solid Wall
Pier
Wall

H
20

L
20

Type
Cantilever

E t Flexure
4.00

E t Shear
3.00

Et
7.00

R / (E t)
0.143
R = 100%

L
20
20
10
5

Type
Cantilever
Fixed
Fixed
Fixed

E t Flexure
4.00
-0.13
1.00
8.00

E t Shear
3.00
-1.50
3.00
6.00

Et

R / (E t)

Wall with Opening


Pier
Wall
Bottom
Left
Right
L&R
Total

H
20
10
10
10

__
Page 498 of 533
524

7.00
-1.63
4.00
14.00
3.11
8.49

0.250
0.071
0.321
0.118
R = 82%

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Rigidity Determination for Shear Wall & Shear Wall with Opening Using Finite Element Method
INPUT DATA & DESIGN SUMMARY
DIMENSIONS
L=
30
ft
H=
thk =

20
8

ft
in

b=
h=

5
10

ft
ft

OPENING

L1 =

10

ft

H1 =

ft

E=
=

1350
0.25

LOCATION

R = 4403 kips
PROPERTIES

ksi
(Poisson's ratio)

Not Apply

R = 3787 kips

The opening reduced the lateral load capacity by 14%.

ONE STORY ?
Yes
(Cantilever Wall with Fixed Base Only)
ANALYSIS
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Joint

Solid Wall with Fixed at Top & Base


Reaction (kips)
Deflection (in)
X
Y
X
Y

Element
Joints
1, 2, 6, 7
2, 3, 7, 8
3, 4, 8, 9
4, 5, 9, 10
6, 7, 11, 12
7, 8, 12, 13
8, 9, 13, 14
9, 10, 14, 15
11, 12, 16, 17
14, 15, 18, 19
16, 17, 20, 21
18, 19, 22, 23
20, 21, 24, 25
21, 22, 25, 26
22, 23, 26, 27
24, 25, 28, 29
25, 26, 29, 30
26, 27, 30, 31

Solid Wall with Fixed at Base only


Reaction (kips)
Deflection (in)
X
Y
X
Y

982

-1823

0.00

605

0.39

1157

-105

0.00

843

0.08

456

-41

0.00

422

0.03

1537

59

0.00

1494

-0.02

1655

1982

0.00

1038

-0.33

0.87

0.06

0.85

0.39

0.89

0.00

0.85

0.08

0.89

0.00

0.85

0.03

0.89

0.00

0.85

-0.02
-0.33

10

0.88

-0.04

0.87

11

0.75

0.11

0.71

0.37

12

0.76

0.01

0.70

0.08

13

0.80

-0.01

0.73

0.03

14

0.76

0.00

0.70

-0.02
-0.31

15

0.76

-0.08

0.73

16

0.49

0.14

0.45

0.29

17

0.50

0.02

0.42

0.06

18

0.50

0.00

0.42

-0.01

19

0.51

-0.10

0.47

-0.25

20

0.24

0.10

0.22

0.17

21

0.23

0.01

0.18

0.04

22

23

24

25

26

27

__
0.24

0.00

0.18

0.00

0.25

-0.08

0.22

-0.14

0.12

0.06

0.11

0.09

0.11

0.01

0.08

0.02

0.11

0.00

0.08

0.00

0.13

-0.05

0.11

-0.08

28

-1149

-1811

0.00

0.00

-1123

-2568

0.00

0.00

29

-1202

-261

0.00

0.00

-722

-571

0.00

0.00

30

-1895

28

0.00

0.00

-1309

27

0.00

0.00

31

-1541

1973

0.00

0.00

-1249

3112

0.00

0.00

R=

-5788

kips

R=

-4403

Page 499 of 533


524

kips

Dimension (ft)
X
Y
10.0
2.5
2.5
2.5
2.5
2.5
15.0
2.5
10.0
2.5
2.5
2.5
2.5
2.5
15.0
2.5
10.0
5.0
15.0
5.0
10.0
5.0
15.0
5.0
10.0
2.5
5.0
2.5
15.0
2.5
10.0
2.5
5.0
2.5
15.0
2.5

Thick.
(in)
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

(cont'd)

Joint

Opening Wall with Fixed at Top & Base


Reaction (kips)
Deflection (in)
X
Y
X
Y

Opening Wall with Fixed at Base only


Reaction (kips)
Deflection (in)
X
Y
X
Y

664

-1608

0.00

393

0.33

1040

708

0.00

691

0.02

483

-31

0.00

595

0.03

1224

-831

0.00

1216

0.04

1504

1888

0.00

892

-0.30

0.90

0.06

0.87

0.33

0.91

-0.02

0.88

0.01

0.90

0.00

0.88

0.03

0.90

0.02

0.87

0.04
-0.30

10

0.89

-0.04

0.87

11

0.78

0.10

0.74

0.32

12

0.82

-0.05

0.76

0.00

13

0.84

-0.01

0.79

0.02

14

0.79

0.04

0.74

0.05
-0.29

15

0.77

-0.07

0.75

16

0.48

0.14

0.44

0.27

17

0.51

-0.07

0.44

-0.03

18

0.48

0.06

0.42

0.07

19

0.51

-0.11

0.47

-0.24

20

0.21

0.10

0.19

0.15

21

0.19

-0.03

0.14

-0.02

22

0.19

0.04

0.15

0.04

23

0.23

-0.08

0.20

-0.14

24

0.10

0.06

0.09

0.08

25

0.09

-0.02

0.07

-0.01

26

0.09

0.02

0.07

0.02

27

0.11

-0.04

0.10

-0.07

28

-974

-1643

0.00

0.00

-944

-2268

0.00

0.00

29

-883

638

0.00

0.00

-491

364

0.00

0.00

30

-1765

-978

0.00

0.00

-1329

-999

0.00

0.00

1857

0.00

0.00

2903

0.00

0.00

31

-1292

R=

-4915

kips

-1023

R=

-3787

kips

__
Page 500 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Shear Wall Analysis for Shear Wall with Opening Using Finite Element Method
INPUT DATA & DESIGN SUMMARY
DIMENSIONS
L=
30
ft
H=
thk =

20
8

ft
in

b=
h=

5
10

ft
ft

OPENING

LOCATION

PROPERTIES

DIAPHRAGM
( 0 = flexible,
TOP LOADS

L1 =

10

ft

H1 =

ft

E=
=

1350
0.25

EA =
= rigid, 0~
P=
M=
V=

ksi
(Poisson's ratio)

Not Apply

kips, (flexible diaphragm)

= semirigid. ASCE 7 12.3.1)


62.5
225
11.25

DRAG FORCE AROUND OPENING

Joint
No.
12
14
21
22

kips
ft-kips
kips

Section
2 - 12
3 - 13
4 - 14
11-12
14-15
16-17
18-19
20-21
22-23
28-29
30-31

Drift = 0.005 in

Joint
No.
28
29
30
31

Tension Positive (kips)

Horiz
0.16
-1.40
-1.29
0.54

Vert
-10.20
-23.71
-12.84
-17.97

Section Force (kips, ft-kips)


Axial
Shear Moment
1.57
-0.50
3.55
2.51
4.08
7.15
-2.51
4.08
-3.05
13.42
-2.64
-67.09
49.08
-8.61
368.11
13.42
-2.64
-67.09
49.08
-8.61
368.11
13.42
2.64
-67.09
49.08
8.61
368.11
8.15
0.64
-40.74
46.24
9.54
346.77

Reaction (kips)
Horiz
Vert
-0.39
0.08
-0.02
11.89
-2.54
16.49
-8.29
34.04

POSITIVE DIRECTION

ANALYSIS
EQUIVALENT JOINT LOADS
Load (kips)
Joint
No.
Horiz
Vert
1
1.88
-4.58
2
2.34
-8.33
3
0.94
-4.58
4
3.28
-21.88
5
2.81
-23.13

No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Element
Joints
1, 2, 6, 7
2, 3, 7, 8
3, 4, 8, 9
4, 5, 9, 10
6, 7, 11, 12
7, 8, 12, 13
8, 9, 13, 14
9, 10, 14, 15
11, 12, 16, 17
14, 15, 18, 19
16, 17, 20, 21
18, 19, 22, 23
20, 21, 24, 25
21, 22, 25, 26
22, 23, 26, 27
24, 25, 28, 29
25, 26, 29, 30
26, 27, 30, 31

Force (kips)
X
Y

Deflection (in)
X
Y

1.88

-4.58

0.004

-0.001

2.34

-8.33

0.004

-0.003

0.94

-4.58

0.004

-0.004

3.28

-21.88

0.004

-0.004

2.81

-23.13

0.005

-0.006

0.003

-0.001

0.003

-0.003

0.003

-0.003

Joint

Dimension (ft)
X
Y
10.0
2.5
2.5
2.5
2.5
2.5
15.0
2.5
10.0
2.5
2.5
2.5
2.5
2.5
15.0
2.5
10.0
5.0
15.0
5.0
10.0
5.0
15.0
5.0
10.0
2.5
5.0
2.5
15.0
2.5
10.0
2.5
5.0
2.5
15.0
2.5

Thick.
(in)
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8

__
Page 501 of 533
524

0.003

-0.004

10

0.004

-0.006

11

0.002

0.000

12

0.003

-0.003

13

0.003

-0.003

14

0.003

-0.003

15

0.004

-0.005

16

0.001

0.000

17

0.001

-0.002

18

0.001

-0.002

19

0.003

-0.003

20

0.000

0.000

21

0.000

-0.001

22

0.000

-0.001

23

0.001

-0.002

24

0.000

0.000

25

0.000

0.000

26

0.000

0.000

27

0.001

-0.001

28

-0.39

0.08

29

-0.02

11.89

30

-2.54

16.49

31

-8.29

34.04

(cont'd)
Corner Forces (kips)

Element Joints
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

1.87

-4.58

1.04

-6.46

-1.95

3.85

-0.96

7.19

1.31

-1.88

-1.09

-2.20

0.43

1.66

-0.65

2.41

2.02

-2.39

-0.45

-2.93

-0.92

0.82

-0.65

4.50

10

3.74

-18.95

2.81

-23.13

-3.62

17.86

-2.93

24.22

11

12

1.95

-3.85

0.58

-7.48

-2.22

3.22

-0.31

8.11

12

13

-0.05

-1.36

-0.67

-1.25

-0.12

2.08

0.84

0.53

13

14

2.24

-1.98

0.27

-2.51

-0.84

-0.53

-1.68

5.02

10

14

15

4.00

-19.84

2.93

-24.22

-3.80

18.69

-3.13

25.37

11

12

16

17

2.22

-3.22

0.42

-10.20

-2.46

1.90

-0.18

11.52

14

15

18

19

5.48

-23.71

3.13

-25.37

-4.72

20.84

-3.88

28.24

16

17

20

21

2.46

-1.90

0.18

-11.52

-1.55

0.58

-1.10

12.84

18

19

22

23

4.72

-20.84

3.88

-28.24

-3.47

17.97

-5.13

31.11

20

21

24

25

1.55

-0.58

-0.19

-8.21

-0.99

0.24

-0.36

8.55

21

22

25

26

1.29

-4.63

0.54

-3.99

-0.28

3.71

-1.55

4.91

22

23

26

27

2.94

-13.98

5.13

-31.11

-1.83

12.64

-6.24

32.45

24

25

28

29

0.99

-0.24

-0.35

-7.91

-0.39

0.08

-0.25

8.07

25

26

29

30

0.99

-4.36

0.08

-3.76

0.23

3.82

-1.30

4.30

26

27

30

31

3.30

-13.78

6.24

-32.45

-1.24

12.19

-8.29

34.04

__
Page 502 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Discontinuous Shear Wall Analysis Using Finite Element Method


INPUT DATA & DESIGN SUMMARY
L1 =
DIMENSIONS

15

ft

L2 =

15

ft

L3 =

10

ft

H1 =

16

ft

H2 =

14

ft

BEAM PROPERTIES

WALL PROPERTIES

Eb =

3156

ksi

Gb =

1372

ksi

Ib =

106667

in

Ab =

800

in

thk =
E=
=

8
1350

in
ksi

0.25

(Poisson's ratio)

4
2

The bottom shear wall reactions

COLUMN PROPERTIES

Ec1 =

3156

ksi

no column input 0 ==>

Ac1 =

576

in

Ec2 =

3156

ksi

Ac2 =

576

in2

The beam deflection at end wall

P=

62.5

kips

The column axial forces

M=
V=

20
11.25

ft-kips
kips

TOP LOADS

34.25

kips

4.17

ft-kips

Vw =

11.25

kips

The max beam section forces


no column input 0 ==>

Pw =
Mw =

Vb =

0.47

kips

Mb =

4.68

ft-kips

b =

0.003

in, downward

Pc1 =

28.71

kips

Pc2 =

-0.47

kips

ANALYSIS

EQUIVALENT JOINT LOADS


Load (kips)
Joint
No.
Horiz
Vert
1
1.41
-7.40
2
2.81
-15.13
3
2.81
-15.63
4
2.81
-16.13
5
1.41
-8.23

No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Note:
1.
2.

Element
Joints
1, 2, 6, 7
2, 3, 7, 8
3, 4, 8, 9
4, 5, 9, 10
6, 7, 11, 12
7, 8, 12, 13
8, 9, 13, 14
9, 10, 14, 15
11, 12, 17, 18
12, 13, 18, 19
17, 18, 20, 21
18, 19, 21, 22
13, 14
14, 15
15, 16
15, 23
16, 24

Dimension (ft)
X
Y
7.5
7.0
7.5
7.0
7.5
7.0
7.5
7.0
7.5
7.0
7.5
7.0
7.5
7.0
7.5
7.0
7.5
8.0
7.5
8.0
7.5
8.0
7.5
8.0
7.5
0
7.5
0
10.0
0
0
16.0
0
16.0

Thick.
(in)
8
8
8
8
8
8
8
8
8
8
8
8
Beam
Beam
Beam
Column
Column

Force (kips)
X
Y

Deflection (in)
X
Y

1.41

-7.40

0.009

-0.004

2.81

-15.13

0.010

-0.006

2.81

-15.63

0.009

-0.007

2.81

-16.13

0.009

-0.008

1.41

-8.23

0.009

-0.008

0.007

-0.002

0.008

-0.005

0.008

-0.006

0.008

-0.007

10

0.008

-0.006

11

0.005

-0.001

12

0.006

-0.003

13

0.007

-0.006

14

0.007

-0.006

15

0.008

-0.003

16

0.008

0.000

17

0.002

0.000

18

0.002

-0.001

Joint

19

0.003

-0.003

20

-3.52

-3.72

21

-2.53

15.65

22

-5.20

22.33

23

0.00

28.71

24

0.00

-0.47

__

This is pure Finite Element Method without rigidity reduction factor. For cracked wall the rigidity reduction factor,
such as ( 1 / 20.5 ), can be input by wall thickness.
For beam and columns design, the section forces must consider UBC 1630.8.2.1 or ASCE 7-05 12.3.3.3.

Page 503 of 533


524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Two Story Moment Frame Analysis using Finite Element Method


INPUT DATA & SUMMARY
COLUMN SIZE (WF, Tube, or Pipe)
1- 5 = HSS12.500X0.500

Pipe

ORIENTATION =
2-6=

x-x
WF

W12X65
x-x

ORIENTATION =
BEAM SIZE (WF, Tube, or Pipe)
3-4=

WF

W18X65
x-x

ORIENTATION =
5-6=

Tube

HSS12X6X5/8
ORIENTATION =

y-y

,(flat)

DIMENSIONS
H1 =

14

ft

H2 =

16

ft

L1 =

22

ft

DESIGN SECTION FORCES


Column

LOADS
F1 =

19.5

kips, (horiz. to right)

F2 =

12

kips, (horiz. to right)

Beam

N15 =

-6.2

k,(compre.)

N26 =

-38.2

k,(compression)

V15 =

12.7

kips

V26 =

25.7

kips

M15 =

91.3

ft-kips

M26 =

207.6

V34 =

24.4

kips

V56 =

8.6

ft-kips
kips

P1 =

kips, (downward)

M34 =

237.1

ft-kips

M56 =

57.7

ft-kips

P2 =

kips, (downward)

M34, mid =

0.0

ft-kips

M56, mid =

9.2

ft-kips

q1 =

0.26

kips / ft, (horiz. to right)

q2 =

0.32

kips / ft, (horiz. to right)

w1 =

0.64

kips / ft, (downward)

H,3 =

0.9927

in, (horiz. to right)

w2 =

0.45

kips / ft, (downward)

H,4 =

0.9849

in, (horiz. to right)

H,5 =

2.3865

in, (horiz. to right)

H,6 =

2.3820

in, (horiz. to right)

HORIZONTAL DEFLECTION

75 % of (d / 2)

RIGID-ZONE LENGTH FACTOR

ANALYSIS
Coordinates (ft)

Reaction (k, ft-k)

Joint J Deflection (in,deg)

Joint

RX

RY

RM

12.72

-4.20

91.28

0.000

0.000

0.000

22

25.72

38.18

207.55

0.000

0.000

0.000

14

0.993

-0.001

0.117

22

14

0.985

0.011

0.250

30

2.386

0.001

0.391

22

30

2.382

0.016

0.370

End Joint

Moment (ft-k)

Shear (k)

I
4
(in )

Length

A
2
(in )

(ksi)

(ft)

Mid

Axial
(k)

17.2

191

29000

13.43

91.28

-1.98

75.60

4.20

-12.72

10.98

19.1

533

29000

13.43

207.55

-34.91

137.72

-38.18

-25.72

25.72

19.1

1070

29000

21.65

-141.00

-10.52

-237.06

16.46

10.53

-24.39
2.81

17.2

191

29000

15.62

59.71

-8.03

23.16

-6.21

-7.80

19.1

533

29000

15.62

86.64

-14.37

57.90

-13.69

-9.25

9.25

18.7

107

29000

21.65

-23.23

9.16

-57.66

9.25

-1.14

-8.61

__

(The length & forces not included Rigid-Zone.)

Page 504 of 533


524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

X Braced Frame Analysis using Finite Element Method


INPUT DATA & SUMMARY
COLUMN SIZE
1- 6 =
W10X45

WF
x-x

ORIENTATION =
2-7=

WF

W10X45
y-y

ORIENTATION =

,(weak axis)

BEAM SIZE
W14X22

3-5=

WF
y-y

ORIENTATION =
W16X40

6-7=

,(flat)
WF

BRACE SIZE
Tube

HSS8X8X1/2
DIMENSIONS

THE MAX SECTION FORCES

H1 =

14

ft

H3 =

18

ft

H2 =

14

ft

H4 =

16

ft

L1 =

6.5

ft

L2 =

ft

Column

N16 =

14.4

k,(tension)

N27 =

-50.2

V16 =

0.0

kips

V27 =

0.0

k,(compression)
kips

M16 =

-0.4

ft-kips

M27 =

-0.1

ft-kips

Brace

Tmax =

68.5

k,(tension)

Cmin =

30.3

k,(tension)

Beam

N67 =

2.5

k,(tension)

M35 =

0.004779 ft-kips

EQUIVALENT JOINT LOADS


F3 =

10

kips, (horiz. to right)

P3 =

-12.5

kips, (downward)

3 =

0.0870

in, (horiz. to right)

F5 =

11

kips, (horiz. to right)

P5 =

-13

kips, (downward)

5 =

0.0884

in, (horiz. to right)

F6 =

15

kips, (horiz. to right)

P6 =

-11

kips, (downward)

6 =

0.1862

in, (horiz. to right)

F7 =

16

kips, (horiz. to right)

P7 =

-9.8

kips, (downward)

7 =

0.1963

in, (horiz. to right)

ANALYSIS

Coordinates (ft)

Load & Reaction (k)

Joint

Fx / Rx

Fy / Ry

-24.19

-66.52

14.5

-4

-27.81

112.82

14

10

-12.5

6.5

14

14.5

14

11

-13

28

15

-11

14.5

30

16

-9.8

Element

-0.0005

0.0870

0.0063

-0.0006
-0.0004

End Joint

1
2

Joint I Deflection (in, rad)

Joint J Deflection (in,rad)

-0.0004

0.0828

-0.0085

0.0003

0.0828

-0.0085

0.0003

-0.0004

0.0884

-0.0281

-0.0005

0.0870

0.0063

-0.0002

0.0828

-0.0085

-0.0002

0.0828

-0.0085

-0.0002

0.0884

-0.0281

-0.0002

0.0870

0.0063

-0.0006

0.1862

0.0180

-0.0006

0.0828

-0.0085

0.0006

0.1862

0.0180

0.0006

0.0828

-0.0085

-0.0006

0.1963

-0.0467

-0.0006

0.0884

-0.0281

-0.0005

0.1963

-0.0467

-0.0006

0.1862

0.0180

-0.0004

0.1963

-0.0467

-0.0004

I
(in4)

Length

A
(in2)

Element

(ksi)

(ft)

(k)

(k)

13.3

248

29000

14.00

0.0

-0.4

14.4

0.0

End Joint

Moment (ft-k)

Axial

Shear

13.5

125

29000

15.44

0.0

0.0

57.5

0.0

13.5

125

29000

19.70

0.0

0.0

-68.5

0.0

13.3

53.4

29000

18.00

0.0

-0.1

-50.2

0.0

6.49

29000

6.50

0.0

-0.0048

-10.1

0.0

6.49

29000

8.00

0.0048

0.0

11.0

0.0

13.3

248

29000

14.00

0.4

0.0

26.9

0.0

13.5

125

29000

15.44

0.0

0.0

41.4

0.0

13.5

125

29000

17.89

0.0

0.0

-30.3

0.0

13.3

53.4

29000

16.00

0.1

0.0

-37.2

0.0

11.8

518

29000

14.64

0.0

0.0

2.5

0.0

__
Page 505 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE:

Wind Girt Deflection Analysis of Wood, Metal Stud, and/or Steel Tube
INPUT DATA & ANALYSIS RESULTS
DIMENSIONS
12
ft
L=
H1 =
4
ft
H2 =

H3 =

ft

ft
GIRT SECTIONS
LINTEL = 6 x 8 - Douglas Fir-Larch No. 1
SILL = (2) - 2 x 6 - No. 1
JAMB = HSS6X2X1/4
WIND LOAD
I=
EXPOSURE =
MEAN ROOF HEIGHT =

V=
BUILDING CORNER ?

1
C
36
90
Yes

(ASCE 7-05 Tab 6-1)


ft, (ASCE 7-05 Tab 6-3)
mph, (IBC 09 Tab 1609.3.1)
(Zone 5, ASCE 7-05 Fig 6-11& 6-17)

THE DESIGN IS ADEQUATE.


DEFLECTION LIMITATION (IBC 09 Tab 1604.3)

L / 240

ANALYSIS
OUT-OF-PLANE WIND FORCE (ASCE 7-05, Eq.6-22)

p = q h ( G C P ) ( G C Pi ) = ( 0.00256 K h K Zt K dV 2I ) ( G C P ) ( G C Pi )
Where

Kh

1.02

Kd

0.85

, (ASCE Tab. 6-4)

84.00

ft , (ASCE Fig. 6-11A or 6-17)

Effective Area =

22.4

psf

USE
16
psf
(IBC 09 Table 1604.3 note: f )

, (ASCE Tab. 6-3)


2

GC p

-1.07

, (ASCE Fig. 6-11A or 6-17)

GC pi

0.18

, (ASCE Fig. 6-5)

KZt

Flat, (ASCE 6.5.7.2)

CHECK LINTEL DEFLECTION

5w L4
=
384 EI

Where

<

0.31 in

w
E

=
=

0.11
1600

104

L / 240

0.60

in

[Satisfactory]

L / 240

0.60

in

[Satisfactory]

H / 240

0.90

kips / ft
ksi
in4

CHECK SILL DEFLECTION

5w L4
=
384 EI

Where

<

0.53 in

w
E

=
=

0.08
1700

42

kips / ft
ksi
in4

CHECK JAMB DEFLECTION


max
Where

NOTE :

0.53 in, at 9.00 ft from top,

R lintel

0.67

R sill
E

=
=

0.48
29000

13

<

in

[Satisfactory]

kips

__
kips
ksi
4
in

Since girt size controlled by deflection, not by capacity, the wind coefficient w, 1.3, does not apply. (IBC 09 Section 1605.3.2)

Page 506 of 533


524

PROJECT :
CLIENT :
JOB NO. :
DATE :
Column Deformation Compatibility Design using Finite Element Method
INPUT DATA & DESIGN SUMMARY
COLUMN SECTION (WF, HSS tube & pipe)
STORY HEIGHTS

W10X60

H above =
H =

14
14

ft
ft, continued top & bot

H below =

16

ft

COLUMN AXIAL LOAD, ASD

PAGE :
DESIGN BY :
REVIEW BY :

P DL =

20

kips

P LL =

18

kips

4.2

in

EXPECTED DEFORMATION
(ASCE 7-05 12.12.4, CBC 01 1633A.2.4 )

STRONG AXIS BENDING ? (1=Yes, 0=No)


1
yes, strong axis, x-x, bending.
=>

THE DESIGN IS ADEQUATE.


ANALYSIS
DETERMINE JOINT DEFLECTIONS AND SECTION FORCES
E = 29000 ksi
50
ksi
Fy =
A =

17.6

in2

I=

341

G=

JOINT DEFLECTIONS UNDER ONLY


X (in)
Y (in)
(deg)
Note
N1
0.496192
0
0
N2

0.0000

-1.007175

N3

4.2

0.0000

-0.932621

N4

4.2

0.0000

0.457379

P u = 1.2 P DL + 1.0 P LL =
Mu

11154

ksi

in4

THE DESIGN COLUMN SECTION FORCES UNDER ONLY


V (k)
P (k)
M (ft-k)
Note
N2
225.24
-33.09
0.000
N3

33.09

238.00

0.000

42.00 kips

= (P DL + P LL ) + M =

Vu = V =

251.30 ft-kips
33.09 kips

CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)

P r + 8 M rx + M ry
P c 9 M cx 4.2M cy

, for P r 0.2
Pc

P r + M rx + M ry
2Pc
M cx M cy

, for P r < 0.2


Pc

Where

KL x =

14

(KL / r)max =

<

Pr =

42.00

kips

M rx =

251.30

ft-kips

M ry =

0.00

200

0.9 x 643.43

M cx = M n =

0.9 x 289.99

M cy = M n =

0.9 x 145.83

KL y =

=
=

>

Note:

115.67

kips

579.09
Pr
260.99
M rx
72.92

>

Vn =

1.0

Vu

14

ft, for y-y axial load.

M ry

kips, (AISC 360-05 Chapter E)


[Satisfactory]
ft-kips, (AISC 360-05 Chapter F)
[Satisfactory]
ft-kips, (AISC 360-05 Chapter F)
[Satisfactory]

__
>

[Satisfactory]

[Satisfactory]

>

CHECK SHEAR CAPACITY (AISC 360-05, G)

<

1.00

ft, for x-x axial load.

65

Pc = Pn =

[Satisfactory]

The govining case is always that only the design story column has Story Drift and other stories no drift, since the other
story at same direction drifts, including PD effects, will reduce the section forces of design story column. The opposite story
drifts are not Expected Deformation, because Expected Deformation can not be developed from Linear Modes Analysis
after CQC or SRSS.

Page 507 of 533


524

PROJECT :
CLIENT :
JOB NO. :

DATE :

PAGE :
DESIGN BY :
REVIEW BY :

Interior Wall Lateral Forces Based on IBC 09 / CBC 10


INPUT DATA
AVERAGE ROOF HEIGHT FROM GROUND
h
DESIGN WALL BOTTOM FLOOR HEIGHT
z
STORY HEIGHT
s
PLAIN (UNREINFORCED) MASONRY WALL ? (0=no, 1=yes)
Wp
WALL OPERATING WEIGHT

=
=
=

SEISMIC PARAMETER
SEISMIC IMPORTANCE FACTOR

=
=

SDS
Ip

48
24
14
1
86

ft
ft
ft
Yes, (ASCE Tab. 13.5-1 Item 1)

psf

0.96 (ASCE 7-05 Sec 11.4.4)


1.5 (ASCE 7-05 Tab 11.5-1)

MASONRY ANCHOR TO TOP FLEXIBLE DIAPHRAGM?

No, (ASCE Tab. 13.5-1 Footnote b)

DESIGN SUMMARY
Out-of Plane Force for Wall Design
Top Anchorage Force
Bottom Anchorage Force

Fp
Fanch, top
Fanch, bot

=
=
=

54
555
429

psf, ASD
lbs/ft, ASD
lbs/ft, ASD

ANALYSIS
Out-of Plane Force for Wall Design (ASCE 7-05 Sec. 13.3 & IBC/CBC 1607.13)

F p = Max 0.5 ( F p , top , F p , bot ) , 5 psf


F p , top

or

bot =

Where :

, ASD Level

0.4a p S DS I pW p
1
z
Max 0.3S DS I pW p , Min
1+ 2
1.4
h
Rp
ap

1.0

(ASCE Tab. 13.5-1)

Rp

, 1.6 S DS I pW p

Top
Bot

z, attachment height, (ft)


38.0
24.0
Wall Design

Fp (psf, ASD)
61
(0.71 Wp)
47
(0.55 Wp)
54
(0.63 Wp)

z, attachment height, (ft)


38.0
24.0

Fanch (lbs/ft, ASD)


555
(0.92 Wp)
429
(0.71 Wp)

1.5

(ASCE Tab. 13.5-1)

Out-of-plane seismic force for anchorage design (ASCE 7-05 Sec. 13.3 & 13.4)

F anch =

0.4a p S DS I pW p
z
1.3
Max 0.3S DS I pW p , Min
1+ 2
1.4
h
Rp

, 1.6 S DS I pW p

1
0.8S DS I pW p , for concrete or masonry to flexible diaphragm
1.4
Where :

ap

1.0

(ASCE Tab. 13.5-1)

Rp

Top
Bot

(If diaphragm flexible, no factor 1.3 apply, ASCE 13.4.2.a)

1.5

(ASCE 13.4.2)

__
Page 508 of 533
524

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Interior Wall Lateral Forces Based on IBC 09 / CBC 10


INPUT DATA
AVERAGE ROOF HEIGHT FROM GROUND
DESIGN WALL BOTTOM FLOOR HEIGHT
WALL HEIGHT
WALL OPERATING WEIGHT

h
z
d
Wp

=
=
=
=

SEISMIC PARAMETER
SEISMIC IMPORTANCE FACTOR

SDS
Ip

=
=

48
24
10
86

ft
ft
ft
psf

0.96 (ASCE 7-05 Sec 11.4.4)


1.5 (ASCE 7-05 Tab 11.5-1)

DESIGN SUMMARY
Fp
Fanch
Manch

Out-of Plane Force for Wall Design


Shear Anchorage Force
Anchorage Moment

=
=
=

71 psf, ASD
1533 lbs/ft, ASD
7666 ft-lbs/ft, ASD

ANALYSIS
Out-of Plane Force for Wall Design (ASCE 7-05 Sec. 13.3 & IBC/CBC 1607.13)

F p = Max

1
0.3S DS I pW
1.4

0.4a p S DS I pW
1
Min
1.4
Rp

1+ 2

z
h

1
1.6 S DS I pW
1.4

, 5 psf

0.82 Wp
=

Where :

ap

2.5

(ASCE Tab. 13.5-1)

Rp

71

psf, ASD Level

2.5

(ASCE Tab. 13.5-1)

Out-of-plane seismic force for anchorage design (ASCE 7-05 Sec. 13.3 & 13.4)

F anch =

0.4a p S DS I pW p
z
1.3
Max 0.3S DS I pW p , Min
1+ 2
h
1.4
Rp

M anch
Where :

=
ap

0.5 d F anch =
=

2.5

(ASCE Tab. 13.5-1)

, 1.6 S DS I pW p

7666 ft-lbs/ft, ASD Level


Rp

1.5

(ASCE 13.4.2)

__
Page 509 of 533
524

1.78 Wp

1533 lbs/ft, ASD Level

PROJECT :
CLIENT :
JOB NO. :

DATE :

PAGE :
DESIGN BY :
REVIEW BY :

Interior Wall Lateral Forces Based on IBC 09 / CBC 10


INPUT DATA
AVERAGE ROOF HEIGHT FROM GROUND
h
DESIGN WALL BOTTOM FLOOR HEIGHT
z
STORY HEIGHT
s
WALL HEIGHT
d
PLAIN (UNREINFORCED) MASONRY WALL ? (0=no, 1=yes)
Wp
WALL OPERATING WEIGHT

=
=
=
=

48
24
14
9.5
1
86

SEISMIC PARAMETER
SEISMIC IMPORTANCE FACTOR

=
=

0.96 (ASCE 7-05 Sec 11.4.4)


1.5 (ASCE 7-05 Tab 11.5-1)

SDS
Ip

MASONRY ANCHOR TO TOP FLEXIBLE DIAPHRAGM?

ft
ft
ft
ft
Yes, (ASCE Tab. 13.5-1 Item 1)

psf

No, (ASCE Tab. 13.5-1 Footnote b)

DESIGN SUMMARY
Out-of Plane Force for Wall Design
Top Anchorage Force
Bottom Anchorage Force

Fp
Fanch, top
Fanch, bot

=
=
=

54
376
291

psf, ASD
lbs/ft, ASD
lbs/ft, ASD

ANALYSIS
Out-of Plane Force for Wall Design (ASCE 7-05 Sec. 13.3 & IBC/CBC 1607.13)

F p = Max 0.5 ( F p , top , F p , bot ) , 5 psf


F p , top

or

, ASD Level

0.4a p S DS I pW p
1
z
Max 0.3S DS I pW p , Min
1+ 2
bot =
1.4
h
Rp

Where :

ap

1.0

(ASCE Tab. 13.5-1)

Rp

, 1.6 S DS I pW p

1.5

z, attachment height, (ft)


Fp (psf, ASD)
38.0
61
(0.71 Wp)
24.0
47
(0.55 Wp)
Wall Design
54
(0.63 Wp)
(z at top must be attachment point at main structure floor)

Top
Bot

(ASCE Tab. 13.5-1)

Out-of-plane seismic force for anchorage design (ASCE 7-05 Sec. 13.3 & 13.4)

F anch =

0.4a p S DS I pW p
1.3
z
1+ 2
Max 0.3S DS I pW p , Min
1.4
h
Rp

, 1.6 S DS I pW p

1
0.8S DS I pW p , for concrete or masonry to flexible diaphragm
1.4
Where :

ap

1.0

(ASCE Tab. 13.5-1)

Rp

Top
Bot

Fanch (lbs/ft, ASD)


376
(0.92 Wp)
291
(0.71 Wp)

(If diaphragm flexible, no factor 1.3 apply, ASCE 13.4.2.a)

1.5

(ASCE 13.4.2)

__
Page 510 of 533
524

z, attachment height, (ft)


38.0
24.0

PROJECT :

PAGE :

CLIENT :

DESIGN BY :

JOB NO. :

DATE :

REVIEW BY :

Lateral Loads of Storage Racks, with Hilti Anchorage, Based on ASCE 7-05
Dimensions
D =

3.5

ft

L =

ft

h3 =

15.5

ft

Determine Rack Base Shear (Derived from ASCE 7-05 15.5.3 & 13.3)

V =F p =

0.4a p S DS I pW p

1
z
Max 0.3S DS I pW p , Min
1 + 2 , 1.6 S DS I pW p =
1.5
h

Rp

0.34 W p , ASD

= 504.5 lbs,
(ASD level force at each L rack)
Where

S DS =
Ip =

1.121
1.5

(ASCE 7-05 11.4.4)


(ASCE 7-05 15.5.3.1)

Wp = W1 + W2 + W3 =

lbs, each L rack

1500.0

ap =

2.5

(ASCE 7-05 15.5.3)

Rp =

(ASCE 7-05 15.5.3)

z =

ft, rack floor height from building ground (ASCE 7-05 13.3.3.1)

h =

36

ft, average building roof height (ASCE 7-05 13.3.3.1)

Calculate Vertical Distribution of Rack Base Shear (lbs) & Allowable Elastic Drift (ASCE 7-05 12.8.3 & 15.5.3.3)
k

Level

Wx

hx

hx

3
2
1

500
500
500
1500.0

15.5
8
0.5

15.5
8.0
0.5

Where

k =

Wxhx

7750
4000
250
12000

Fx , ASD (12.8-11)
325.8
168.2
10.5
504.5

xe,allowable, in, ASD


6.643
3.429
0.214

( 0.65 Wx )
( 0.34 Wx )
( 0.02 Wx )

(ASCE 7-05 15.5.3.2)

xe,allowable, ASD = 5% hx/1.4, (ASCE 7-05 15.5.3.4)


Calculate Lateral Forces (lbs), at Each Joint of Both Directions, and Max Reactions (lbs) (ASCE 7-05 15.5.3.2)
Case a , (ASCE 7-05 15.5.3.2 a)

Level

ex (ft)

Wx

RT

RC

RV

3
2
1

3
3
3

335
335
335
1005.0

109.1
56.3
3.5
169.0

327
169
11
507.0

1012.4

2017.4

169.0

Case b , (ASCE 7-05 15.5.3.2 b)

Level

ex (ft)

Wx

RT

RC

RV

3
2
1

500
0
0
500.0

84.1
0.0
0.0
84.1

252
0
0
252.2

638.8

1138.8

84.1

(cont'd)
Anchorage & Summary
2

- 1/2" , w/ 2" emb in 2.5 ksi conc, KWIK Bolt-TZ required at each column base. (ICC ESR-1917)
(P s / P t ) + (V s / V t ) =
Where

Notes:
1.
2.

0.895

<

1.20

[SATISFACTORY]

Ps =

506.2

lbs

P t = 606

Vs =

84.5

lbs,

V t = 1419.5 lbs / bolt, (ICC ESR-1917)

lbs / bolt, (ICC ESR-1917)

Input W 2 & e2 zero for only 2 level rack, or lump some levels together at their top for more than 3 levels.
Rack self should be designed by Manufacturers Institute Specifications (RMI), or from ICC report.
a.
Vertical impact load factor is 1.25 (RMI 2.4)
b.
Max beam deflection is 1/180 (RMI 2.5)
c.
Allowable soil capacity for slab on grade is 500 psf.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Alternate All-Heights Method, Based on ASCE 7-2010


INPUT DATA
Exposure category (B, C or D, ASCE 7-10 26.7.3)
Importance factor (ASCE 7-10 Table 1.5-2)

Basic wind speed (ASCE 7-10 26.5.1 or 2012 IBC)


Topographic factor (ASCE 7-10 26.8 & Table 26.8-1)
Building height (IBC/CBC, 1609.6.1.1)
Building length
Building width (IBC/CBC, 1609.6.1.1)
Effective area of components (or Solar Panel area)

Iw
V
Kzt
h
L
B
A

C
1.00
136
1
22
100
50
28

=
=
=
=
=
=
=

for all Category


mph
Flat
ft
ft
ft
ft2

DESIGN SUMMARY
Max building horizontal force normal to building length, L, face
Max overturning moment at wind normal to building length, L, face
Max building horizontal force normal to building length, B, face
Max overturning moment at wind normal to building length, B, face
Max building upward force
Max building torsion force

=
=
=
=
=
=

89.6
3147.6
37.7
3316.5
136.9
1007.6

kips
ft - kips
kips
ft - kips
kips
ft - kips

ANALYSIS
Velocity pressure

qs = 0.00256 V
where:

47.35

psf

qs = wind velocity pressure at atandard height of 33 feet (IBC/CBC Table 1609.6.2(1) )

Design pressures for MWFRS

Pnet = qs Kz Cnet [ I Kzt ]


where:

(IBC/CBC, Equation 16-34)

P = pressure in appropriate zone.

Pmin =

16

psf (ASCE 7-10 28.4.4)

Kz = velocity pressure exposure coefficient evaluated at height, h, (Tab. 6-3, Case 1,pg 79)
Cnet = Kd [(G Cpf )-(G Cpi )]

0.85

, (IBC/CBC, 1609.6.2 / Table 1609.6.2(2). The equation used on following calcs.)

Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250)

0.85

G Cp f = product of gust effect factor and external pressure coefficient, see table below. (Fig. 28.4-1, page 300 & 301)
G Cp i = product of gust effect factor and internal pressure coefficient.(Tab. 26.11-1, Enclosed Building, page 258)
=
0.18
or
-0.18

Surface

z (ft)
0 - 15
20
22

P (psf) with
- GCPi
GCPi
17.40
30.67
18.81
32.08
19.26
32.53

Surface
Side Wall

z (ft)
All

Normal to L Face

Windward Wall

Surface
Leeward

z (ft)
All

Normal to L Face

Surface

Dist. (ft)

Roof

0 - 11
22
44
50

P (psf) with
GCPi
- GCPi
-29.30
-16.03

P (psf) with
GCPi
- GCPi
-22.82
-9.55

P (psf) with
GCPi
- GCPi
-35.77
-22.50
-35.77
-22.50
-22.82
-9.55
-16.35
-3.08

Normal to B Face

Surface
Leeward

z (ft)
All

Normal to B Face

Surface

Dist. (ft)

Roof

0 - 11
22
44
100

P (psf) with
GCPi
- GCPi
-16.35
-3.08

P (psf) with
GCPi
- GCPi
-35.77
-22.50
-35.77
-22.50
-22.82
-9.55
-16.35
-3.08

Figure 27.4-8, page 271

cont'd

Base Forces

VBase

(kips)

MBase
MT

Normal to L Face
Case 1
Case 2

Normal to B Face
Case 1
Case 2

Wind with Angle


Case 3
Case 4

ASCE-7

90

67

38

28

95

55

(ft - kips)

3148

2361

3316

2487

4848

2574

Fig. 27.4-8

(ft - kips)

1008

212

915

Page 271

FUpward

(kips)

106

79

77

58

137

74

Vmin

(kips)

35

35

18

18

40

39

Min. wind

FUp,min

(kips)

80

80

80

80

80

80

Sec. 6.1.4.1

Design pressures for components and cladding

a = width of edge strips, Fig 28.4-1, note 9, page 301, MAX[ MIN(0.1B, 0.1L, 0.4h), MIN(0.04B, 0.04L), 3] =

Effective
Area (ft2)
Comp.

28

Comp. & Cladding


Pressure
( psf )

Zone 1
- GCP
GCP

0.26

-0.96

GCP

Zone 2
- GCP

GCP

- GCP

0.26

-1.49

0.26

-2.04

Zone 1

Zone 2

Zone 3

Zone 3

5.00

Zone 4
GCP
- GCP

ft

Zone 5
GCP
- GCP

0.83
-0.92
0.83
-1.12
(Walls reduced 10 %, Fig. 6-11A note 5.)
Zone 4

Zone 5

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

16.05

-41.85

16.05

-61.46

16.05

-81.84

37.20

-40.51

37.20

-47.85

PROJECT :
CLIENT :
JOB NO. :
Suspended Ceiling Seismic Loads Based on ASCE 7-10

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

INPUT DATA & DESIGN SUMMARY


3.5

kips

HEIGHT & DIMENSIONS


h=
60
ft, average roof height (ASCE 7-10 page 114)
H=
48
ft, this floor top level height
D=
6
ft
T=
8
in, from floor top to bottom anchorage point

Wp =

HANGER TRIBUTARY WEIGHT (4 psf min. 2010 CBC 1615A.1.16)

Wp
FH

SEISMIC COEFFICIENTS
1
(ASCE 7-10 11.4.4)
SDS =
Ip =

1.5

ap =

Rp =

FV

(ASCE 7-10 13.1.3)


(ASCE 7-10 Table 13.5-1 or Table 13.6-1)
( ASCE 7-10: 2.5 for ceilings on Table 13.5-1, 1.5 for lighting fixtures on Table 13.6-1)

1.5

FH =

2.40

Wp (SD)

FV =

1.90

Wp (SD)

=
=

1.71

Wp (ASD)

1.36

Wp (ASD)

=
=

6.00

kips, ASD level horizontal load

4.75

kips, ASD level downward load

ANALYSIS
FH = Fp = (KH) MAX{ 0.3SDSIpWp , MIN[ 0.4apSDSIp(1+2z/h)/Rp Wp , 1.6SDSIpWp ] }

, (ASCE 7-10 13.3.1, page 113)

= 2.5 MAX{ 0.45Wp , MIN[ 0.96Wp , 2.40Wp ]}


=

2.40 Wp , (SD level load)

1.71 Wp , (ASD)

where

z=
KH =

H-D=
2.5

6.00

kips, ASD level load

42.00 ft, height in structure of point of horizontal anchorage


(ASCE 7-10 13.4.2 & 2010 CBC 1615A.1.14, but 1.0 for anchor on wood/metal or member/T-bar self)

FV = (1 + KV ) Wp

where

1.90 Wp , (SD level load)

1.36 Wp , (ASD)

z=
H-T=
47.33
KV = KH 0.2 SDS / 1.4 =

4.75

kips, ASD level downward load

ft, height in structure of point of vertical anchorage


0.36 (vertical seismic factor, ASD level)

PROJECT :

PAGE :

CLIENT :

DESIGN BY :

JOB NO. :

DATE :

REVIEW BY :

Lateral Loads of Storage Racks, with Red Head Anchorage, Based on ASCE 7-05

Dimensions
D =

3.5

ft

L =

ft

h3 =

15.5

ft

Determine Rack Base Shear (Derived from ASCE 7-05 15.5.3 & 13.3)

V =F p =

0.4a p S DS I pW p

1
z
Max 0.3S DS I pW p , Min
1 + 2 , 1.6 S DS I pW p =
1.5
h

Rp

0.34 W p , ASD

= 504.5 lbs,
(ASD level force at each L rack)
Where

S DS =
Ip =

1.121
1.5

(ASCE 7-05 11.4.4)


(ASCE 7-05 15.5.3.1)

Wp = W1 + W2 + W3 =

lbs, each L rack

1500.0

ap =

2.5

(ASCE 7-05 15.5.3)

Rp =

(ASCE 7-05 15.5.3)

z =

ft, rack floor height from building ground (ASCE 7-05 13.3.3.1)

h =

36

ft, average building roof height (ASCE 7-05 13.3.3.1)

Calculate Vertical Distribution of Rack Base Shear (lbs) & Allowable Elastic Drift (ASCE 7-05 12.8.3 & 15.5.3.3)
k

Level

Wx

hx

hx

3
2
1

500
500
500
1500.0

15.5
8
0.5

15.5
8.0
0.5

Where

k =

Wxhx

7750
4000
250
12000

Fx , ASD (12.8-11)
325.8
168.2
10.5
504.5

xe,allowable, in, ASD


6.643
3.429
0.214

( 0.65 Wx )
( 0.34 Wx )
( 0.02 Wx )

(ASCE 7-05 15.5.3.2)

xe,allowable, ASD = 5% hx/1.4, (ASCE 7-05 15.5.3.4)


Calculate Lateral Forces (lbs), at Each Joint of Both Directions, and Max Reactions (lbs) (ASCE 7-05 15.5.3.2)
Case a , (ASCE 7-05 15.5.3.2 a)

Level

ex (ft)

Wx

RT

RC

RV

3
2
1

3
3
3

335
335
335
1005.0

109.1
56.3
3.5
169.0

327
169
11
507.0

1012.4

2017.4

169.0

Case b , (ASCE 7-05 15.5.3.2 b)

Level

ex (ft)

Wx

RT

RC

RV

3
2
1

500
0
0
500.0

84.1
0.0
0.0
84.1

252
0
0
252.2

638.8

1138.8

84.1

(cont'd)
Anchorage & Summary
2

- 1/2" , w/ 1 7/8" emb in 2.5 ksi conc, ITW Red Head Wedge required at each column base. (ICC ESR-2251)
(P s / P t ) + (V s / V t ) =
Where

Notes:
1.
2.

0.991

<

1.20

[SATISFACTORY]

Ps =

506.2

lbs

P t = 557

Vs =

84.5

lbs,

V t = 1033.5 lbs / bolt, (ICC ESR-2251)

lbs / bolt, (ICC ESR-2251)

Input W 2 & e2 zero for only 2 level rack, or lump some levels together at their top for more than 3 levels.
Rack self should be designed by Manufacturers Institute Specifications (RMI), or from ICC report.
a.
Vertical impact load factor is 1.25 (RMI 2.4)
b.
Max beam deflection is 1/180 (RMI 2.5)
c.
Allowable soil capacity for slab on grade is 500 psf.

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Tornado and Hurricane Based on 2012 IBC Section 423 & FEMA 361/320

INPUT DATA
Exposure category (FEMA input C only, ICC-500 C or B)
Design wind speed (FEMA 361 Table 2-2)

V =

C
250

Shelter height to eave

he =

ft

Shelter height to ridge (hr = he for flat roof)


Shelter length
Shelter width
Effective area of components

hr =
L =
B =

10
12
8

ft
ft
ft

A =

ft

mph

Strom Shelter

DESIGN SUMMARY
Max horizontal force normal to Shelter length, L, face
Max horizontal force normal to shelter length, B, face
Max total horizontal torsional load
Max total upward force
Max component pressure (see the last table for components and cladding)

=
=
=
=
=

14.87
8.37
23.14
13.21
428.40

kips, SD level (LRFD level), Typ.


kips
ft-kips
kips
psf

ANALYSIS
Importance factor (ASCE 7-10 Table 1.5-2)

Iw =

1.00

for all Category

Topographic factor (ASCE 7-10 26.8 & Table 26.8-1)

Kzt =

1.00

, (FEMA 361 Table 2-1)

Wind directionality factor (ASCE 7-10 Table 26.6-1)

Kd =

1.00

, (FEMA 361 Table 2-1)

G Cpi =

0.55

Product of gust effect factor and internal pressure coefficient

or

-0.55

, (FEMA 361 Table 2-1)

Velocity pressure

qh = 0.00256 Kh Kzt Kd V2
where:

136.00 psf

qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316)

Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1, pg 299)


h = mean roof height
< 60 ft, [Satisfactory]

=
=

0.85
9.00 ft
(ASCE 7-10 26.2.1)

Design pressures for MWFRS

p = qh [(G Cpf )-(G Cpi )]


where:

p = pressure in appropriate zone. (Eq. 28.4-1, page 298).

pmin =

16

psf (ASCE 7-10 28.4.4)

G Cp f = product of gust effect factor and external pressure coefficient, see table below. (Fig. 28.4-1, page 300 & 301)
a = width of edge strips, Fig 28.4-1, note 9, page 301, MIN{MAX[ MIN(0.1B, 0.1L, 0.4h), MIN(0.04B, 0.04L), 3], 0.25B} =

Net Pressures (psf), Basic Load Cases


26.57
Roof angle =
Surface

1
2
3
4
5
6
1E
2E
3E
4E
5E
6E

G Cp f

Net Pressure with

0.55
-0.10
-0.45
-0.39

(+GCp i )
-0.04
-88.28
-135.62
-127.92

(-GCp i )
149.56
61.32
13.98
21.68

0.73
-0.19
-0.58
-0.53

24.18
-100.68
-154.35
-147.55

173.78
48.92
-4.75
2.05

Roof angle =
G Cp f

-0.45
-0.69
-0.37
-0.45
0.40
-0.29
-0.48
-1.07
-0.53
-0.48
0.61
-0.43

0.00

Net Pressure with

(+GCp i )
-136.00
-168.64
-125.12
-136.00
-20.40
-114.24
-140.08
-220.32
-146.88
-140.08
8.16
-133.28

(-GCp i )
13.60
-19.04
24.48
13.60
129.20
35.36
9.52
-70.72
2.72
9.52
157.76
16.32

2.00

Net Pressures (psf), Torsional Load Cases


Roof angle = 26.57
Surface

1T
2T
3T
4T
Surface

5T
6T

G Cp f

Net Pressure with

(+GCp i ) (-GCp i )
0.55
-0.01
37.39
-0.10
-22.07
15.33
-0.45
-33.90
3.50
-0.39
-31.98
5.42
Roof angle = 0.00
G Cp f

0.40
-0.29

Net Pressure with

(+GCp i ) (-GCp i )
-5.10
32.30
-28.56
8.84

ft

Basic Load Case A (Transverse Direction)


Surface

1
2
3
4
1E
2E
3E
4E

Min. wind
28.4.4

Area
(ft2)

64
36
36
64
32
18
18
32
Horiz.
Vert.
Horiz.
Vert.

Basic Load Case B (Longitudinal Direction)

Pressure (k) with

(+GCp i )
0.00
-3.16
-4.85
-8.19
0.77
-1.80
-2.76
-4.72
14.87
-11.25
1.92
-1.54

Surface

(-GCp i )
9.57
2.19
0.50
1.39
5.56
0.88
-0.09
0.07
14.87
3.12
1.92
-1.54

2
3
5
6
2E
3E
5E
6E

Min. wind
28.4.4

Torsional Load Case A (Transverse Direction)


Surface

1
2
3
4
1E
2E
3E
4E
1T
2T

Area
(ft2)

16
9
9
16
32
18
18
32
48
27

Pressure (k) with

(+GCp i )
0.00
-0.79
-1.21
-2.05
0.77
-1.80
-2.76
-4.72
0.00
-0.59

36
36
38
38
18
18
34
34
Horiz.
Vert.
Horiz.
Vert.

(+GCp i )
-6.03
-4.48
-0.78
-4.34
-3.94
-2.63
0.28
-4.53
8.37
-13.21
1.15
-1.54

-1
-5

0
1

23

23

Area

Surface

(+GCp i ) (-GCp i )
0
5
-1
0
1
0
4
-1
3
22
-3
2
5
0
19
0
0
-5
1
-1

3T
27
-0.91
0.09
4T
48
-1.54
0.26
Total Horiz. Torsional Load, MT

Pressure (k) with

(ft2)

(-GCp i )
-0.68
0.88
4.91
1.34
-1.27
0.05
5.36
0.55
8.37
5.47
1.15
1.54

Torsional Load Case B (Longitudinal Direction)

Torsion (ft-k)

(-GCp i )
2.39
0.55
0.13
0.35
5.56
0.88
-0.09
0.07
1.79
0.41

Area

Pressure (k) with

Torsion (ft-k)

(ft2)

(+GCp i ) (-GCp i ) (+GCp i ) (-GCp i )


2
36
-6.03
-0.68
-3
0
3
36
-4.48
0.88
2
0
5
2
-0.04
0.26
0
0
6
2
-0.23
0.07
0
0
2E
18
-3.94
-1.27
9
3
3E
18
-2.63
0.05
-6
0
5E
34
0.28
5.36
1
16
6E
34
-4.53
0.55
14
-2
5T
36
-0.18
1.16
0
-2
6T
36
-1.03
0.32
-2
1
Total Horiz. Torsional Load, MT
15.1
15.1

Design pressures for components and cladding

p = qh[ (G Cp) - (G Cpi)]


where:

p = pressure on component. (Eq. 30.4-1, pg 318)


pmin =

16.00

psf (ASCE 7-10 30.2.2)

G Cp = external pressure coefficient.


see table below. (ASCE 7-10 30.4.2)

Effective
Area (ft2)
Comp.

Comp. & Cladding


Pressure
( psf )

Zone 1
GCP
- GCP

0.50

-0.90

Zone 1

GCP

Zone 2
- GCP

GCP

- GCP

0.50

-1.90

0.50

-2.60

Zone 2

Zone 3

Zone 3

Zone 4
GCP
- GCP

1.00

-1.10

Zone 4

Zone 5
GCP
- GCP

1.00

-1.40

Zone 5

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

Positive

Negative

142.80

-197.20

142.80

-333.20

142.80

-428.40

210.80

-224.40

210.80

-265.20

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Stiffness Matrix Generator for Irregular Beam/Column


INPUT DATA & SUMMARY
Coordinate
Joint No.

X (in)

Joint Number

Segment

Y (in)

Number

From

To

E
(ksi)

-5.00

29000

-6.2125

29000

A
(in2)

I
(in4)

38.443

626.1413

40.40725 1046.096

-7.425

18

29000

42.3715 1584.472

-8.6375

27

29000

44.33575 2247.047

-9.85

36

29000

-9.85

163.4626

k=

1.2

,(1.2 for Rectangle or 10/9 for Circle)

L=

9.1

in

Q=

POISSON'S RATIO

46.3

3060

0.3

SHEAR STRESS DISTRIBUTION FACTOR

ANALYSIS
SINGLE SEGMENT STIFFNESS MATRIX
Segment Number

A
1

[k] =

G=
2

11154

ksi

339.6605711 -1332.480181 8647.877521 -339.6605711 1332.480181 8647.877521

-1332.480181 10050.72042 1165.061277 1332.480181 -10050.72042 1165.061277

8647.877521 1165.061277 642086.4218 -8647.877521 -1165.061277 308835.992

-339.6605711 1332.480181 -8647.877521 339.6605711 -1332.480181 -8647.877521

1332.480181 -10050.72042 -1165.061277 -1332.480181 10050.72042 -1165.061277

8647.877521 1165.061277 308835.992 -8647.877521 -1165.061277 642086.4218

ENTIRE ELEMENT ( Irregular Beam/Column) STIFFNESS MATRIX


V1

[K] =

H1

M1

V6

H6

M6

V1

286.6279877 120.2446712 -2331.293139 -286.6279877 -120.2446712 -23301.24972

H1

120.2446712 7494.362469 25074.47452 -120.2446712 -7494.362469 275.298004

M1

-2331.293139 25074.47452 498818.1079 2331.293139 -25074.47452 -163980.868

V6

-286.6279877 -120.2446712 2331.293139 286.6279877 120.2446712 23301.24972

H6

-120.2446712 -7494.362469 -25074.47452 120.2446712 7494.362469 -275.298004

M6

-23301.24972 275.298004 -163980.868 23301.24972 -275.298004 2296508.014

INPUT EXAMPLE
SECTION =
L=

H = 13.62188 ft

W18X158
3

ft

D=

Coordinate
Joint No.

X (in)

Y (in)

Segment
Number

10

in

Joint Number
From

To

(ksi)

A
(in2)

I
(in4)

-5.00

0.00

29000

38.4

626

-6.21

9.00

29000

40.4

1,046

-7.43

18.00

29000

42.4

1,584

-8.64

27.00

29000

44.3

2,247

-9.85

36.00

29000

46.3

3,060

-9.85

163.46

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Lateral Drift Mitigation for Cantilever Column using Post-Tensioning


INPUT DATA & DESIGN SUMMARY
FLEXURAL STIFFNESS OF CANTILEVER COLUMN
HEIGHT OF CANTILEVER COLUMN
h=
PT =
AXIAL POST-TENSIONING FORCE
LATERAL LOAD AT TOP OF COLUMN

The Lateral Drift at Top of Column


(The drift has been reduced

F=

EI =
12
1638

ft
kips

2.1

kips

1782968 in -kips

'=
0.46
in
61% by post-tension)

ANALYSIS

'

2 F h 3  wh 4
6 EI  2 P T h 2
3' P T
2h 2

where

'=
(

w=

0.46
1.17
0.05

in
in, without post-tensioning force.)
kips / ft

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Blast Deformation Mitigation for Gravity Column using Post-Tensioning


INPUT DATA & DESIGN SUMMARY
EI =

FLEXURAL STIFFNESS OF GRAVITY COLUMN


STORY HEIGHT OF GRAVITY COLUMN
AXIAL POST-TENSIONING FORCE

H=
PT =

10
1638

ft
kips

EQUIVALENT BLAST LOADING


BLAST LOADING LOCATION

F=
h=

65
5

kips
ft

The max deformation on Gravity Column


(The deformation has been reduced

1782968 in -kips

'=
0.17
in
87% by post-tension)

ANALYSIS

3 H  h / 3
x

3' P T

wt  wb
x H  x

0.06415F H  h
2
2
'
H  H  h

HEI

where

'=
(

wt + wb =
x=

1.5

H h
6 EI

wt  wb

0.171
1.312

in
in, at 5.00 ft from bottom, without post-tensioning force.)

0.331
5.00

kips / ft
ft

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Design for Low-Profile Solar Photovoltaic Arrays on Flat Roof, Based on SEAOC PV2-2012
INPUT DATA & DESIGN SUMMARY
Exposure category (B, C or D, ASCE 7-10 26.7.3)
Basic wind speed (ASCE 7-10 26.5.1 or 2012 IBC)
Topographic factor (ASCE 7-10 26.8 & Table 26.8-1)

V =
Kzt =

C
110
1
20

Mean roof height or max monoslope roof height


Mean parapet height (PV2 Figure 29.9-1 Notes)

hpt =

ft

Overall building length

WL =

182

ft

Overall building width

WS =

110

ft

h =

Array location
To North

dN =

50

ft

To South

dS =

10

ft

To West

dW =

80

ft

To East

dE =

30

ft

mph
Flat
ft

Solar Panel Net (toward & away) LRFD Pressure


North-West corner 1 = 59.0 psf
North-East corner 2 = 81.2 psf

Effective wind area for structural element being designed


A =

3.13

ft

South-West corner 3 =
South-East corner 4 =

60.9
72.0

psf
psf

Max possible pressures for any solar arrays on the roof


p max = 165.9 psf

ANALYSIS
Velocity pressure

qh = 0.00256 Kh Kzt Kd V2
where:

23.70

psf

qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316)
Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1, pg 299)

0.90

Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250)

=
=

0.85
20.00 ft
(ASCE 7-10 26.2.1)
(ASCE 7-10 26.2.2)

h = mean roof height

< 60 ft, [Satisfactory]


< Min (L, B), [Satisfactory]
Design pressures for rooftop solar arrays

p = qh (G Crn)
where:

p = pressure on solar panels (PV2 Eq. 29.9-1).


pmin =

16.00

psf (ASCE 7-10 30.2.2)

(G Crn) = pE [(G Crn)nom (c)]

, (PV2 Figure 29.9-1 Notes)

1.00
, (PV2 Figure 29.9-1 Notes)
p =
E = arry edge factors, (PV2 Figure 29.9-1).
(G Crn)nom = nominal net pressure coefficient, (PV2 Figure 29.9-1).
c =
=

0.90
10.00

, from and lp .(PV2 Figure 29.9-1 Notes)


deg, angle of plane of panel to roof. (PV2 Figure 29.9-1)

lp =

5.00

, chord length of solar panel. (PV2 Figure 29.9-1)

apv = Min [ h , 0.5 (h Max(W L , W S )) 0.5 ] =


An = 1000 A / [max(a pv , 15 ft)] 2 =
h1 =

0.50

20.00

ft, solar panel height above roof at low edge.

hc = Min [ Min( h 1 , 1 ft ) + l p sin , 0.1 a pv ] =


Corner
1
2
3
4

No. Zone
1
2
2
3

0o - 5o
1.12
1.49
1.49
1.70

(15o - 35o)
1.37
1.94
1.94
2.35

1.37

Maximum possible pressures for any solar arrays on this roof


165.88 psf

p = qh (G Crn) =
where:

p =
E=

1.00
2.00

c =

1.00

(G Crn)nom =

ft

ft2 , (PV2 Figure 29.9-1 Notes)

7.83

3.50

ft, conservatively for multi-solar arrays.

(G Crn)nom c
1.25
1.71
1.71
2.02

E
2.00
2.00
1.50
1.50

p (psf)
59.01
81.20
60.90
71.97

PROJECT :

PAGE :

CLIENT :
JOB NO. :

DESIGN BY :
REVIEW BY :

DATE :

Three Story Comparison of Seismic and Wind Based on 2012 IBC / 2013 CBC
INPUT DATA & DESIGN SUMMARY
L=

150

ft, Building Length (perpendicular, not shown)

B=

50

ft, Building Width (as shown)

Hr =

4.5

ft

H3 =

ft

W3 =

225

H2 =

ft

W2 =

337.5

kips

H1 =

ft

W1 =

375

kips

Seismic

kips, (12.8-12)

SDS =

0.96

(ASCE 7 Sec 11.4.4)

SD1 =

0.55

(ASCE 7 Sec 11.4.4)

S1 =

0.54

(ASCE 7 Sec 11.4.1)

, (ASCE 7-10 26.7.3)

Wind Exposure (B, C or D)


Wind Speed

V=

145

mph, (ASCE 7-10 26.5.1)

Base Shear (kips)

Lateral Force (kips)

Vb

F1
F2
F3
22.6
38.5
37.7
( 0.06 Wx ) ( 0.11 Wx ) ( 0.17 Wx )
24.1
25.6
25.6

Seismic , ASD

98.9
(0.11W)
88.9

Wind , ASD

Overturning (ft-kips)
Mo
1802.1
5699.3

Determine Seismic Factors


R=

6.5

I=

Ct =

0.02

(ASCE 7 Tab 12.8-2)

hn =

25.0

ft

0.75

(ASCE 7 Tab 12.8-2)

x=

T = Ct (hn) =

(ASCE 7 Tab 12.2-1)


(2012 IBC Tab 1604.5 & ASCE 7 Tab 11.5-1)

0.224

sec, (ASCE 7 Sec 12.8.2.1)

Determine Wind Factors


Kzt =

Kd =

0.85

G Cp i =

0.18

pmin =

16

a=

5.00

ft (ASCE 7-10 Fig 28.4-1, note 9, page 301)

Kh =

0.96

(ASCE 7-10 Tab. 28.3-1, pg 299)

qh =

43.83

psf (ASCE 7-10 Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316)

(ASCE 7-10 26.8 & Table 26.8-1)


(ASCE 7-10 Tab. 26.6-1, for building, page 250)
or

-0.18

(ASCE 7-10 Tab. 26.11-1, Enclosed Building, page 258)

psf (ASCE 7-10 28.4.4)

PROJECT :

PAGE :

CLIENT :
JOB NO. :

DESIGN BY :
REVIEW BY :

DATE :

Two Story Comparison of Seismic and Wind Based on 2012 IBC / 2013 CBC
INPUT DATA & DESIGN SUMMARY
L=

150

ft, Building Length (perpendicular, not shown)

B=

50

ft, Building Width (as shown)

Hr =

4.5

ft

H2 =

ft

W2 =

337.5

H1 =

ft

W1 =

375

Seismic

kips, (12.8-12)
kips

SDS =

0.96

(ASCE 7 Sec 11.4.4)

SD1 =

0.55

(ASCE 7 Sec 11.4.4)

S1 =

0.54

(ASCE 7 Sec 11.4.1)

, (ASCE 7-10 26.7.3)

Wind Exposure (B, C or D)


Wind Speed

V=

145

mph, (ASCE 7-10 26.5.1)

Base Shear (kips)


Vb
Seismic , ASD

F1

75.2
(0.11W)
54.4

Wind , ASD

Lateral Force (kips)

Overturning (ft-kips)

F2

27.8
47.3
( 0.07 Wx ) ( 0.14 Wx )
21.5
21.5

Mo
1055.1
4673.8

Determine Seismic Factors


R=

6.5

I=

Ct =

0.02

(ASCE 7 Tab 12.8-2)

hn =

17.0

ft

0.75

(ASCE 7 Tab 12.8-2)

x=

T = Ct (hn) =

(ASCE 7 Tab 12.2-1)


(2012 IBC Tab 1604.5 & ASCE 7 Tab 11.5-1)

0.167

sec, (ASCE 7 Sec 12.8.2.1)

Determine Wind Factors


Kzt =

Kd =

0.85

G Cp i =

0.18

pmin =

16

(ASCE 7-10 26.8 & Table 26.8-1)


(ASCE 7-10 Tab. 26.6-1, for building, page 250)
or

-0.18

(ASCE 7-10 Tab. 26.11-1, Enclosed Building, page 258)

psf (ASCE 7-10 28.4.4)

a=

5.00

ft (ASCE 7-10 Fig 28.4-1, note 9, page 301)

Kh =

0.89

(ASCE 7-10 Tab. 28.3-1, pg 299)

qh =

40.83

psf (ASCE 7-10 Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316)

PROJECT :

PAGE :

CLIENT :
JOB NO. :

DESIGN BY :
REVIEW BY :

DATE :

One Story Comparison of Seismic and Wind Based on 2012 IBC / 2013 CBC
INPUT DATA & DESIGN SUMMARY
L=

150

ft, Building Length (perpendicular, not shown)

B=

50

ft, Building Width (as shown)

Hr =

4.5

ft

H1 =

ft

Seismic

W1 =

375

kips, (12.8-12)

(half perpendicular wall)


SDS =

0.96

(ASCE 7 Sec 11.4.4)

SD1 =

0.55

(ASCE 7 Sec 11.4.4)

S1 =

0.54

(ASCE 7 Sec 11.4.1)

, (ASCE 7-10 26.7.3)

Wind Exposure (B, C or D)


Wind Speed

V=

145

Base Shear (kips)

mph, (ASCE 7-10 26.5.1)

Lateral Force (kips)

Vb
Seismic , ASD

39.6
(0.11W)
24.8

Wind , ASD

Overturning (ft-kips)

F1

Mo

39.6
( 0.11 Wx )
8.3

356.0
4051.4

Determine Seismic Factors


R=

6.5

I=

Ct =

0.02

(ASCE 7 Tab 12.8-2)

hn =

9.0

ft

0.75

(ASCE 7 Tab 12.8-2)

x=

T = Ct (hn) =

(ASCE 7 Tab 12.2-1)


(2012 IBC Tab 1604.5 & ASCE 7 Tab 11.5-1)

0.104

sec, (ASCE 7 Sec 12.8.2.1)

Determine Wind Factors


Kzt =

Kd =

0.85

G Cp i =

0.18

pmin =

16

(ASCE 7-10 26.8 & Table 26.8-1)


(ASCE 7-10 Tab. 26.6-1, for building, page 250)
or

-0.18

(ASCE 7-10 Tab. 26.11-1, Enclosed Building, page 258)

psf (ASCE 7-10 28.4.4)

a=

4.50

ft (ASCE 7-10 Fig 28.4-1, note 9, page 301)

Kh =

0.85

(ASCE 7-10 Tab. 28.3-1, pg 299)

qh =

38.89

psf (ASCE 7-10 Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316)

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Self-Centering Lateral Frame Design Based on ASCE 7-10, AISC 360-10 & ACI 318-11
DESIGN CRITERIA
Self-Centering Lateral Frame (SCLF) can increase ductility capacity, reduce residual drift after earthquake, and cost less for both new and
existing structures. But since post-tensioning tendon have to be used, without acceptable/accurate stiffness matrix, SCLF only can apply to
flexible diaphragm structures, which the seismic loads NOT from FEM analysis.

INPUT DATA & DESIGN SUMMARY


TRIANGLE SECTION (Tube or Pipe)
=>
HSS8X8X5/8
Tube

rmin

16.40

2.98

0.63

8.00

8.00

Fy =

46

ksi

H=
L=

12
18

ft
ft

SEISMIC LOAD (SD level)


F=

200

kips

DIMENSION

POST-TENSIONING TENDONS
1
x
12

fse =

175

strands (each
in2 area )
0.153
ksi, (ACI 318-11 18.6)

(180 ksi suggested for 270 ksi f pu / 243 ksi f py )


END/GUSSET PLATE AND FILLET WELD
1
in. gusset,
0.5
in. weld,

10

in. leg long, typical.

THE CONNECTION DESIGN IS ADEQUATE.


ANALYSIS
CHECK SELF-CENTERING/OVERTURNING (assuming PT as Dead Load)
PT =
321.3 kips
>
( 1 / 0.9 ) ( 2 F H / L ) =
296.30
kips
[Satisfactory]
Where, the factor, 0.9, is from Load Combination, which controls structural overturning design, because Load Combinations are
probability. If an equation value of Load Combinations is negative, that means the structure is inadequate (probability result out-of [0, 1]).
DETERMINE TRIANGLE MEMBER AXIAL FORCES
Bottom
-T/P=
220.49
kips

Left/Tension
34.15
kips

CHECK TRIANGLE MEMBER CAPACITY (AISC 360-10 E3)


IcPn = IcAgFcr =
477.24
kips
>

Puc =

Where

Ic =
KL/r =

kips

[Satisfactory]

0.9

Fe =

72.39
2
2
S E / (KL / r) =

Fcr =

32.33

CHECK FILLET WELD SIZE (AISC 360-10 J2.2b)


w=
0.5
in
#N/A

367.48

Right/Compression
367.48 kips

<
54.61

200

[Satisfactory]

ksi

ksi

>
<

wMIN =

0.25

in

wMAX = (I 0.6 Fu t) / (I 0.707 FEXX) = (0.75 x 0.6 x 58 ksi) t / (0.75 x 0.707 x 70 ksi)
[Satisfactory]
= 1.1795 t =
0.74 in

Lw = (1 / I ) Puc / [(4) (0.6) FEXX (0.707 w)] =

8.25

in

<

10

in

[Satisfactory]

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

General Beam Analysis


INPUT DATA & DESIGN SUMMARY
LL =
LENGTH
10
ft
L=
30
ft
LR =
8
ft
PL =

LOAD & LOCATION

kips

P1 =

3.5

kips

L1 =

11

ft

P2 =

kips

L2 =

ft

P3 =

kips

L3 =

3.5

ft

P4 =

kips

L4 =

ft

LA =

ft

LB =

36

ft

w=
wA =

PR =
6
380
lbs / ft
250
lbs / ft

wB =

600

REACTION
SECTION FORCE

kips

lbs / ft

RL =

32.348

kips

RR =

27.692

kips

M max =

84.080

ft-kips, from left 22.60 ft.

V max =

23.165

kips, from left 10.00 ft.

LATERAL-TORSIONAL BUCKLING LENGTH OF TOP TENSION BENDING


Lb =

14

ft

1. If no diaphragm at top, L b should be the bottom tension bending length (L L + L + L R ).


2. Wood beam EFFECTIVE LENGTH, L e , may conservatively be 1.87 L b (NDS 2012 Table 3.3.3).

DEFLECTION

' Left =
Where

-0.618
E=

in

' Middle = 0.78607 in

29000 ksi

I=

' Right = -0.524 in


301

ANALYSIS

M (ft-k)

SECTION MOMENT
80
60
40
20
0
-20
-40
-60
-80
-100
Length

V (kips)

SECTION SHEAR FORCE


25
20
15
10
5
0
-5
-10
-15
Length

in

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Wind Analysis for Trussed Tower Based on ASCE 7-2010


INPUT DATA
Exposure category (B, C or D)
Importance factor, 1.0 only, (Table 1.5-2)
Basic wind speed (ASCE 7-10 26.5.1)
Topographic factor (26.8 & Table 26.8-1)

Projected area normal to the wind


Height of the centroid of area Af

Iw
V
Kzt

=
=
=
=

C
1.00
90
1

mph
Flat

Af

500

ft2

420

ft

Ratio of solid area to gross area (ASCE 7-10 Figure 29.5-3)

p
F
M

=
=
=

0.35

DESIGN SUMMARY
Max horizontal wind pressure
Max total horizontal force at centroid of base
Max bending moment at centroid of base

83 psf
41.56 kips
17456.57 ft-kips

ANALYSIS
Velocity pressure

qh = 0.00256 Kh Kzt Kd V2
where:

33.61

psf

qh = velocity pressure at mean roof height, h. (Eq. 29.3-1 page 307 & Eq. 30.3-1 page 316)
Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 29.3-1, pg 310)
Kd = wind directionality factor. (Tab. 26.6-1, conservative value, page 250)
h = height of the centroid of area

1.71

=
=

0.95
420.00

G = gust effect factor. (Sec. 26.9)

0.85

Cf = 1.2 Max (4 2 - 5.9 + 4 , 3.4 2 - 4.7 + 3.4) , (conservative value, Figure 29.5-3)

2.91

Af =

500.0

p = q h G Cf =

F = p Af
M=Fh

=
=

where:

83

ft

psf

41.56 kips
17456.6 ft-kips

ft2

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Post-Tensioned Lateral Frame Analysis using Finite Element Method


DESIGN CRITERIA
The post-tensioned lateral frame (PTLF) is self-centering structure, with good hysteretic performance, which can apply to both new and existing
structures of concrete, wood, or steel. The PT tendon forces are not constant, because one direction tendons are released/changed at lateral loads.
There are three kind of forces on each section of beam and column.
1. Primary equivalent loads, PT 1 & PT 2 section forces. The tendon is mentally removed and replaced with all of the loads it exerts on the structure.
2. Secondary section forces from all reactions of primary PT 1 & PT 2 , on free-body structure.
3. Balanced section forces with external loads, F 1 & F 2 . The external loads can be ASD level for serviceability design, or SD level for strength design.

INPUT DATA
DIMENSION

Member

L=

22

ft

H1 =

16

ft

H2 =

18

ft

MODULUS OF ELASTICITY
E=

A (in2)

Ix (in , in plane)

29000

ksi

Column

19.1

533

Bot Beam

19.1

533

Top Beam

19.1

533

LATERAL LOADS

F1 =

18

kips

F2 =

16

kips

TENDON FORCE AFTER ALLOWANCE LOSSES


PT1 =

30

kips, at the first level

PT2 =

30

kips, at the second level

ANALYSIS & DESIGN SUMMARY


Joint Equivalent Load and Deformation
PT 1 & PT 2

Joint

Balanced (PT 1 , PT 2 ) & (F 1 , F 2 )

Fx (kips)

Fy (kips)

Fx (kips)

Fy (kips)

'x (in)

'y (in)

24.26

17.65

24.26

17.65

-24.26

17.65

0.00

0.00

47.48

1.35

41.22

19.00

0.40

0.01

-47.48

1.35

-27.93

-14.65

0.39

-0.01

23.22

-19.00

23.22

-3.00

0.58

0.01

-23.22

-19.00

-23.22

-19.00

0.57

-0.02

Reaction
PT 1 & PT 2

Joint

Balanced (PT 1 , PT 2 ) & (F 1 , F 2 )

Rx (kips)

Ry (kips)

M (ft-k)

Rx (kips)

Ry (kips)

-0.21

-17.65

-1.90

-6.79

19.99

-63.78

0.21

-17.65

1.90

-6.50

-37.64

-61.08

M (ft-k)

Section Forces
Section

Primary equivalent loads, only PT 1 & PT 2


P (kips, axial)

M (ft-kips)

V (kips, in plane)

Secondary section forces from primary reactions


P (kips, axial)

M (ft-kips)

V (kips, in plane)

1 of 1-3

17.65

1.90

0.21

0.00

-1.90

-0.21

3 of 1-3

-17.65

1.49

-0.21

0.00

-1.49

0.21

2 of 2-4

17.65

-1.90

-0.21

0.00

1.90

0.21

4 of 2-4

-17.65

-1.49

0.21

0.00

1.49

-0.21

3 of 3-4

47.18

-0.30

0.00

0.28

0.50

0.00

4 of 3-4

-47.18

0.30

0.00

-0.28

-0.50

0.00

3 of 3-5

19.00

-1.19

-0.09

0.00

0.99

0.06

5 of 3-5

-19.00

-0.37

0.09

0.00

0.17

-0.06

4 of 4-6

19.00

1.19

0.09

0.00

-0.99

-0.06

6 of 4-6

-19.00

0.37

-0.09

0.00

-0.17

0.06

5 of 5-6

23.31

0.37

0.00

-0.06

-0.17

0.00

6 of 5-6

-23.31

-0.37

0.00

0.06

0.17

0.00

(Cont'd)
Section Forces
Section

Balanced (PT 1 , PT 2 ) and (F 1 , F 2 )


P (kips, axial)

M (ft-kips)

V (kips, in plane)

1 of 1-3

-19.99

63.78

6.79

3 of 1-3

19.99

44.93

-6.79

2 of 2-4

37.64

61.08

6.50

4 of 2-4

-37.64

42.91

-6.50

3 of 3-4

34.37

-37.85

-3.42

4 of 3-4

-34.37

-37.36

3.42

3 of 3-5

2.42

-7.08

-0.05

5 of 3-5

-2.42

6.11

0.05

4 of 4-6

19.57

-5.55

0.05

6 of 4-6

-19.57

6.53

-0.05

5 of 5-6

23.27

-6.11

-0.57

6 of 5-6

-23.27

-6.53

0.57

Member Design Forces (kips, ft-kips)


Column

Member
Primary

Secondary

Balanced

Bot Beam Top Beam

17.65

47.18

1.90

0.30

23.31
0.37

0.21

0.00

0.00
-0.06

0.00

0.28

1.90

0.50

0.17

0.21

0.00

0.00
23.27

37.64

34.37

63.78

37.85

6.53

6.79

3.42

0.57

PROJECT :
CLIENT :
JOB NO. :

PAGE :
DESIGN BY :
REVIEW BY :

DATE :

Beam Strengthening Analysis Using External Post-Tensioning Systems


INPUT DATA & DESIGN SUMMARY
DIMENSION
L12 =

20

ft

L23 =

ft

L34 =

10

ft

h=

36

in

BEAM MODULUS OF ELASTICITY

BEAM SECTION

A=

E=

720

in

TENDON FORCE AFTER ALLOWANCE LOSSES

3122.019 ksi

Ix =

PT =

77760

972

in , in plane

kips

ANALYSIS
Camber Deflection

1.2
1

in

0.8
0.6
0.4
0.2
0
Length

ft-kips

Section Moment

2000
1500
1000
500
0
-500
-1000
-1500
-2000
Length

' max =

1.03

in @

21.60

ft, from left

M max =

1420.38

ft-kips @

28.00

ft, from left

V max =

279.30

kips, section shear force

P max =

972.00

kips, section axial compression

PROJECT :
CLIENT :
JOB NO. :
DATE :
Aluminum or WF Member Capacity Based on Aluminum Design Manual 2010 (ASD)

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


MEMBER SIZE

d
8
F tu =

38

ksi

TENSILE YIELD STRESS (T5, T6, T7, T8, or T9)

F ty =

35

ksi

COMPRESSIVE YIELD STRESS (T5 to T9)

F cy =

35

ksi

TENSILE ULTIMATE STRESS (T5 to T9, Table A.3.4)

40
AXIAL COMPRESSION FORCE
P=
STRONG GEOMETRIC AXIS EFFECTIVE LENGTH
WEAK GEOMETRIC AXIS EFFECTIVE LENGTH

kips, ASD
kL x =

ft

kL y =

ft

M rx =

STRONG GEOMETRIC AXIS BENDING MOMENT

10

STRONG GEOMETRIC AXIS BENDING UNBRACED LENGTH


WEAK GEOMETRIC AXIS BENDING MOMENT

A
5.26

Ix
60

Iy
7

E
10100

ft-kips, ASD
L bx =

M ry =

2.5

ft-kips, ASD

V =

22.5

kips

WEB DIRECTION SHEAR LOAD, ASD

b
5

ft

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMPRESSION STRESS IN AXIAL FORCE

F a1

Pn
A g :c

Where

D ckL

Bc  r
F cy
kL

Min
, for
,
 S2
r

nu
ny

S 2E
kL

, for
t S2
r
kL 2
nu r


rx =

3.370

in, (Page V-12 to V-15)

ry =

1.180

in, (Page V-12 to V-15)

kL / r = Max( kL x / r x , kL y / r y ) =
20.34
E=
10100
ksi, (ADM-I Table A.3.4)
B c = F cy [1 + (F cy / 2250) 0.5 ] =
39.37

F a2

Pn
A g :c

Where

17.70

, (ADM-I Table B.4.2)

D c = (B c / 10) (B c / E) 0.5 =

0.25

, (ADM-I Table B.4.2)

C c = 0.41 (B c / D c ) =

65.67

, (ADM-I Table B.4.2)

n u = : c / 0.85 =

1.941

, (ADM-I E.1, E.3-2 & E.3-3)

ny = :c =

1.65

, (ADM-I B.3-2, E.1, E.3-2 & E.3-3)

S2 = Cc =

65.67

, (ADM-I E.3-4)

F cy
b
, for
d S1

t
ny

5.0 D pb
B p 

t
b
, for

S1   S 2
t
nu

E
k
B
b
2
p

, for
t S2

5.0b
t
nu
t

b/t=
k1 =

5.957
0.35

, (ADM-I Figure B.5.1)


, (ADM-I Table B.4.3)

ksi, (compression in column, ADM-I E3)

18.57

ksi, (compression in flanges, ADM-I B.5.4.1)

Wt (lbs/ft)
6.31

(cont'd)
k2 =

2.27

B p = F cy [1 + F cy

F a3

Pn
A g :c

Where

, (ADM-I Table B.4.3)


(1/3)

/ 11.447] =

45.00

, (ADM-I Table B.4.2)

D p = (B p / 10) (B p / E) 0.5 =

0.30

, (ADM-I Table B.4.2)

S 1 = (B p - n u F cy / n y ) / (5.0 D p ) =

2.55

, (ADM-I B5.4.1)

S 2 = k 1 B p / (5.0 D p ) =

10.49

, (ADM-I B5.4.1)

F cy
b
d S1
, for

t
n
y

1.6 D pb
B p 

t
b
, for

S1   S 2
t
nu

E
k
B
b
p
2
t S2
, for

1.6b
t
nu
t

15.97

b/t=
29.130
, (ADM-I Figure B.5.2)
7.96
S 1 = (B p - n u F cy / n y ) / (1.6 D p ) =

, (ADM-I B5.4.2)

S 2 = k 1 B p / (1.6 D p ) =

, (ADM-I B5.4.2)

fa = P / A =

7.60

ksi

32.77

<
F a = Min (F a 1 , F a 2 , F a 3 ) =
[Satisfactory]

CHECK TENSION STRESS IN BENDING MOMENTS


F = P n /(A g : t ) = Min (F ty /n y , F tu / k t n u , 1.3F ty /n y , 1.42F tu / k t n u ) =
Where

kt =

1.00

f = Min (M rx / S x , M ry / S y ) =
Where

ksi, (compression in web, ADM-I B.5.4.2)

Sx =

14.90

8.05
ksi
[Satisfactory]
in, (Page V-12 to V-15)

Sy =

2.92

in, (Page V-12 to V-15)

S 1 = 1.2 (B c - F cy ) / D c =

21.31

S 2 = 1.2 C c =

78.81

, (ADM-I F.2.1)

Cb =

, (ADM-I F.1.1)

1.00

L b / (r y C b

F bx 2

Mn
S x :b

Where

0.5

)=

ksi

19.58

ksi, (tension bending, ADM-I D.1, D.2 & F.8.1.2)

F =

19.58

, (ADM-I Table A.3.3)

<

CHECK COMPRESSION STRESS IN STRONG GEOMETRIC AXIS, x - x, BENDING MOMENT


F cy
Lb
d S1
, for

n
r
Cb
y
y

 D c Lb
B c 1.2r C
y
b

Lb 
Mn
, for S 1 
S2
F bx1

18.81
ny
S x :b
r y Cb

2
Lb t
C bS E
, for
S2
2

Cb
r

y
n y Lb
1.2r y

Where

15.97

ksi

ksi, (compression in beam, ADM-I F.2.1)

, (ADM-I F.2.1)

40.68

F cy
b
, for
d S1

t
n
y

5.0 D pb
B p 

t
b
, for

S1   S 2
t
n
y

b
k 2 B pE
, for
t S2

5.0b
t
ny
t

21.21

b/t=
k1 =

5.957
0.5

, (ADM-I Figure B.5.1)


, (ADM-I Table B.4.3)

k2 =

2.04

, (ADM-I Table B.4.3)

S 1 = (B p - F cy ) / (5.0 D p ) =

6.66

, (ADM-I B5.4.1)

S 2 = k 1 B p / (5.0 D p ) =

14.98

, (ADM-I B5.4.1)

ksi, (compression in flanges, ADM-I B.5.4.1)

(cont'd)

Mn
S x:b

F bx3

Where

1.3F cy
h
, for
d S1

t
ny

mD brh
B br 

h
t
, for

S1   S 2
t
ny

k 2 B brE , for h t S
2

mh
t
ny

26.23

ksi, (compression in web, ADM-I B.5.5.1)

h/t=b/t=
31.739 , (ADM-I Figure B.5.2)
4
in
cc = co =
m=
0.65
, (ADM-I B5.5.1)
B br = 1.3 F cy [1 + F cy (1/3) / 7] =
66.76
, (ADM-I Table B.4.2)
D br = (B br / 20) (6 B br / E)

(1/3)

1.14

, (ADM-I Table B.4.2)

S 1 = (B br - 1.3 F cy ) / (m D br ) =

0.49

, (ADM-I B5.5.1)

S 2 = k 1 B br / (m D br ) =

45.11

, (ADM-I B5.5.1)

f bx = M rx / S x =

8.05

<
F bx = Min (F bx 1 , F bx 2 , F bx 3 ) =
[Satisfactory]

ksi

18.81

ksi

CHECK COMPRESSION STRESS IN WEAK GEOMETRIC AXIS, y - y, BENDING MOMENT

F by

Mn
S y :b

Where

1.3F cy
b
, for
d

t
ny

3.5 D brb
B br 

t
,

n
y

S 2E

, for
3.5b 2
n

y
t

S1

S1 

for

b
 S2
t

26.08

ksi, (compression in web, ADM-I B.5.5.2)

b
t S2
t

b/t=
5.957
, (ADM-I Figure B.5.3)
39.10
, (ADM-I Table B.4.2)
C br = 2B br / (3 D br ) =
S 1 = (B br - 1.3 F cy ) / (3.5 D br ) =
S 2 = C br / 3.5 =

f by = M ry / S y =

10.27

5.34

11.17

, (ADM-I B5.5.2)

ksi

<
F by =
[Satisfactory]

, (ADM-I B5.5.2)

26.08

ksi

CHECK COMBINED COMPRESSION AND BENDING (ADM-I H.1)

P r M rx M ry f a f bx f by






P c M cx M cy F a F bx F by

Max

C my f by
C mx f bx
f a



Check
F a F bx 1  f a / F ex F by 1  f a / F ey

Where

Check =
C mx =

1
0.85

1.30

<
1.33
[Satisfactory]

, (1.33 if IBC/CBC 1605.3.2 apply)

Check if ASD 2005 Eq. 4.1.1-1 apply (1 = Yes, 0 = No)


C my =
0.85

F ex = S 2 E / n u (kL x /r x ) 2 =

253.12

ksi

F ey = S 2 E / n u (kL y /r y ) 2 =

124.14

ksi

CHECK SHEAR STRESS (ADM-I G)

Fs

Vn
A w: v

F ty / 3
h
, for
d S1

t
ny

1.25 D sh

Bs 

t
, for
 S2
S1 

t
ny

h
S 2E

, for
t S2
2
t

1.25h
n y

12.25

ksi, (shear, ADM-I G.2)

(cont'd)
Where

h/t=b/t=
31.739 , (ADM-I Figure G.2.1)
0.5
0.5 (1/3)
/ 9.3] =
26.13
B s = (F cy / 3 ) [1 + (F cy / 3 )
D s = (B s / 10) (B s / E)
C s = 0.41 B s / D s =
S 1 = (B s - F cy / 3
S 2 = C s / 1.25 =

fs = V / Aw =

12.23

0.5

0.5

80.61

0.13

, (ADM-I Table B.4.2)

, (ADM-I Table B.4.2)

, (ADM-I Table B.4.2)

) / (1.25 D s ) =

35.63

64.49

, (ADM-I G.2)

ksi

<
Fs =
[Satisfactory]

, (ADM-I G.2)

12.25

ksi

PROJECT :
CLIENT :
JOB NO. :
DATE :
Member Capacity Based on Aluminum Design Manual 2010 (ASD)

Aluminum

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


MEMBER SIZE

d
4
F tu =

30

ksi

TENSILE YIELD STRESS (T5, T6, T7, T8, or T9)

F ty =

25

ksi

COMPRESSIVE YIELD STRESS (T5 to T9)

F cy =

25

ksi

TENSILE ULTIMATE STRESS (T5 to T9, Table A.3.4)

AXIAL COMPRESSION FORCE


P=
STRONG GEOMETRIC AXIS EFFECTIVE LENGTH

kips, ASD
kL x =
6.4

WEAK GEOMETRIC AXIS EFFECTIVE LENGTH

kL y =
M rx =

STRONG GEOMETRIC AXIS BENDING MOMENT

V strong =

WEAK GEOMETRIC AXIS BENDING MOMENT

M ry =

WEAK DIRECTION SHEAR LOAD, ASD

30

kips

L bx =

20

Ix

Iy

2.7

0.7

E
10100

ft

ft-kips, ASD

0.35

V weak =

A
1.38

ft

1.2

STRONG GEOMETRIC AXIS BENDING UNBRACED LENGTH


STRONG DIRECTION SHEAR LOAD, ASD

3.2

b
1.75

ft

ft-kips, ASD
kips

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMPRESSION STRESS IN AXIAL FORCE

F a1

Pn
A g :c

Where

D ckL

Bc  r
F cy

Min
,
,

nu
ny

S 2E
kL

, for
t S2
r
kL 2
nu r

for

kL
 S2
r
10.18

rx =

1.410

in, (Page V-34 to V-37)

ry =

0.730

in, (Page V-34 to V-37)

kL / r = Max( kL x / r x , kL y / r y ) =
54.47
E=
10100
ksi, (ADM-I Table A.3.4)
B c = F cy [1 + (F cy / 2250) 0.5 ] =
27.64

F a2

Pn
A g :c

Where

, (ADM-I Table B.4.2)

D c = (B c / 10) (B c / E) 0.5 =

0.14

, (ADM-I Table B.4.2)

C c = 0.41 (B c / D c ) =

78.38

, (ADM-I Table B.4.2)

n u = : c / 0.85 =

1.941

, (ADM-I E.1, E.3-2 & E.3-3)

ny = :c =

1.65

, (ADM-I B.3-2, E.1, E.3-2 & E.3-3)

S2 = Cc =

78.38

, (ADM-I E.3-4)

F cy
b
, for
d S1

t
ny

1.6 D pb
B p 

t
b
, for

S1   S 2
t
nu

E
k
B
b
p
2

, for
t S2

1.6b
t
nu
t

b/t=
k1 =

30.000
0.35

k2 =

2.27

B p = F cy [1 + F cy

11.84

ksi, (compression in web, ADM-I B.5.4.2)

, (ADM-I Figure B.5.2)


, (ADM-I Table B.4.3)
, (ADM-I Table B.4.3)
(1/3)

/ 11.447] =

31.39

ksi, (compression in column, ADM-I E3)

, (ADM-I Table B.4.2)

Wt (lbs/ft)
1.62

(cont'd)
D p = (B p / 10) (B p / E) 0.5 =

0.17

, (ADM-I Table B.4.2)

S 1 = (B p - n u F cy / n y ) / (1.6 D p ) =

7.05

, (ADM-I B5.4.2)

S 2 = k 1 B p / (1.6 D p ) =

39.24

, (ADM-I B5.4.2)

fa = P / A =

2.17

ksi

<
F a = Min (F a 1 , F a 2 ) =
[Satisfactory]

CHECK TENSION STRESS IN BENDING MOMENTS


F = P n /(A g : t ) = Min (F ty /n y , F tu / k t n u , 1.3F ty /n y , 1.42F tu / k t n u ) =
kt =

Where

1.00

ksi

15.15

ksi, (tension bending, ADM-I D.1, D.2 & F.8.1.2)

F =

15.15

, (ADM-I Table A.3.3)

f = Min (M rx / S x , M ry / S y ) =
Where

10.18

Sx =

1.37

5.02
ksi
[Satisfactory]
in, (Page V-34 to V-37)

Sy =

0.84

in, (Page V-34 to V-37)

<

ksi

CHECK COMPRESSION STRESS IN STRONG GEOMETRIC AXIS, x - x, BENDING MOMENT

F bx1

Mn
S x:b

F cy
LbS c d
, for
S1

C b I yJ / 2
ny

1
L b S c , for
Lb S c 
S1 
S2
B c  1.6 D c

C b I yJ / 2
C b I yJ / 2
ny

S 2E
Lb S c t
, for
S2

L S

C
b I yJ / 2
b c
2.56n

C b I yJ / 2

S 1 = (B c - F cy ) 2 / (1.6 D c ) 2 =

Where

S 2 = (C c /1.6) 2 =
J=
1.8
Sc = Sx =
Cb =

Mn
S x:b

Where

F bx3

Mn
S x:b

Where

, (ADM-I F.3.1)

, (ADM-I F.1.1)
0.5

/ 2] =

57.29

F cy
b
, for
d S1

t
ny

1.6 D pb
B p 

b
, for

S1   S 2
t
ny

b
k 2 B pE
, for
t S2

1.6b
t
ny
t

b/t=
k1 =

12.000
0.5

, (ADM-I Figure B.5.2)


, (ADM-I Table B.4.3)

k2 =

2.04

, (ADM-I Table B.4.3)

15.15

S 1 = (B p - F cy ) / (1.6 D p ) =

22.81

, (ADM-I B5.4.2)

S 2 = k 1 B p / (1.6 D p ) =

56.06

, (ADM-I B5.4.2)

1.3F cy
h
, for
d S1

t
n
y

h
B br  mD br

h
t
, for

S1   S 2
t
ny

k 2 B br E , for h t S
2

mh
t
ny

h/t=b/t=
cc = co =

ksi, (compression in beam, ADM-I F.3.1)

2399.9 , (ADM-I F.3.1)


, (Page V-34 to V-37)
1.37
in, (Page V-34 to V-37)

1.00

L b S c / [C b (I y J)

F bx 2

129.82

15.15

30.000
in

19.72

, (ADM-I Figure B.5.2)

ksi, (compression in flanges, ADM-I B.5.4.2)

ksi, (compression in web, ADM-I B.5.5.1)

(cont'd)
m=
0.65
, (ADM-I B5.5.1)
46.08
B br = 1.3 F cy [1 + F cy (1/3) / 7] =

, (ADM-I Table B.4.2)

D br = (B br / 20) (6 B br / E) (1/3) =

0.69

, (ADM-I Table B.4.2)

S 1 = (B br - 1.3 F cy ) / (m D br ) =

0.45

, (ADM-I B5.5.1)

S 2 = k 1 B br / (m D br ) =

51.05

, (ADM-I B5.5.1)

f bx = M rx / S x =

10.51

ksi

<
F bx = Min (F bx 1 , F bx 2 , F bx 3 ) =
[Satisfactory]

15.15

ksi

CHECK COMPRESSION STRESS IN WEAK GEOMETRIC AXIS, y - y, BENDING MOMENT

F by

Mn
S y :b

Where

F cy
b
, for
d S1

t
n
y

1.6 D pb
B p 

t
b
, for
 S2

S1 
t
ny

b
k 2 B pE
, for
t S2

1.6b
t
ny
t

b/t=

f by = M ry / S y =

30.000

, (ADM-I Figure B.5.2)

5.02

ksi

<
F by =
[Satisfactory]

13.93

13.93

ksi, (compression in flanges, ADM-I B.5.4.2)

ksi

CHECK COMBINED COMPRESSION AND BENDING (ADM-I H.1)

P r M rx M ry f a f bx f by






P c M cx M cy F a F bx F by

Max

f
C
my by
C mx f bx
fa



Check

1  f a / F ex F by 1  f a / F ey

F
F

a
bx

Where

Check =
C mx =

1
0.85

1.27

<
1.33
[Satisfactory]

, (1.33 if IBC/CBC 1605.3.2 apply)

Check if ASD 2005 Eq. 4.1.1-1 apply (1 = Yes, 0 = No)


C my =
0.85

F ex = S 2 E / n u (kL x /r x ) 2 =

17.31

ksi

F ey = S 2 E / n u (kL y /r y ) 2 =

18.56

ksi

CHECK SHEAR STRESS (ADM-I G)

Fs

Vn
A w: v

F ty / 3
h
, for
d S1

t
ny

B s  1.25 D sh
h

, for
 S2
S1 

t
ny

2E
h
S

, for
t S2
2
t

1.25h
n y

Where

8.75
8.75

ksi, (for strong shear)


ksi, (for weak shear)

h/t=b/t=
30.000 , (for strong shear, Figure G.2)
h/t=b/t=
12.000 , (for weak shear)
B s = (F cy / 3 0.5 ) [1 + (F cy / 3 0.5 ) (1/3) / 9.3] =
18.21
, (ADM-I Table B.4.2)
D s = (B s / 10) (B s / E) 0.5 =

0.08

C s = 0.41 B s / D s =

, (ADM-I Table B.4.2)

96.55

S 1 = (B s - F cy / 3 0.5 ) / (1.25 D s ) =
S 2 = C s / 1.25 =

77.24

f s = V strong / A w =

3.75

ksi

f s = V weak / A w =

5.71

ksi

, (ADM-I Table B.4.2)


39.09

, (ADM-I G.2)

, (ADM-I G.2)

<
<

Fs =

8.75

ksi, (for strong shear)

Fs =
[Satisfactory]

8.75

ksi, (for weak shear)

, (shear, ADM-I G.2)

Aluminum

PROJECT :
CLIENT :
JOB NO. :
DATE :
or CS Member Capacity Based on Aluminum Design Manual 2010 (ASD)

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


MEMBER SIZE

d
8
F tu =

38

ksi

TENSILE YIELD STRESS (T5, T6, T7, T8, or T9)

F ty =

35

ksi

COMPRESSIVE YIELD STRESS (T5 to T9)

F cy =

35

ksi

TENSILE ULTIMATE STRESS (T5 to T9, Table A.3.4)

40
AXIAL COMPRESSION FORCE
P=
STRONG GEOMETRIC AXIS EFFECTIVE LENGTH
WEAK GEOMETRIC AXIS EFFECTIVE LENGTH

kips, ASD
kL x =

ft

kL y =

ft

M rx =

STRONG GEOMETRIC AXIS BENDING MOMENT

STRONG GEOMETRIC AXIS BENDING UNBRACED LENGTH


WEAK GEOMETRIC AXIS BENDING MOMENT

A
4.92

Ix
53

Iy
7

E
10100

ft-kips, ASD
L bx =

M ry =

2.4

ft-kips, ASD

V =

22.5

kips

WEB DIRECTION SHEAR LOAD, ASD

b
3.75

ft

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMPRESSION STRESS IN AXIAL FORCE

F a1

Pn
Ag :c

Where

D ckL

Bc  r
F cy
kL

Min
, for
,
 S2
r

nu
ny

S 2E
kL

, for
t S2
r
kL 2
n
u r


rx =

3.270

in, (Page V-7 to V-10)

ry =

1.200

in, (Page V-7 to V-10)

kL / r = Max( kL x / r x , kL y / r y ) =
20.00
E=
10100
ksi, (ADM-I Table A.3.4)
B c = F cy [1 + (F cy / 2250) 0.5 ] =
39.37

F a2

Pn
A g :c

Where

17.75

, (ADM-I Table B.4.2)

D c = (B c / 10) (B c / E) 0.5 =

0.25

, (ADM-I Table B.4.2)

C c = 0.41 (B c / D c ) =

65.67

, (ADM-I Table B.4.2)

n u = : c / 0.85 =

1.941

ny = :c =

1.65

, (ADM-I B.3-2, E.1, E.3-2 & E.3-3)

S2 = Cc =

65.67

, (ADM-I E.3-4)

, (ADM-I E.1, E.3-2 & E.3-3)

F cy
b
, for
d S1

t
n
y

5.0 D pb
B p 

t
b
, for

S1   S 2
t
nu

E
k
B
b
p
2
, for
t S2

5.0b
t
nu
t

b/t=
k1 =

7.293
0.35

ksi, (compression in column, ADM-I E3)

, (ADM-I Figure B.5.1)


, (ADM-I Table B.4.3)

17.55

ksi, (compression in flanges, ADM-I B.5.4.1)

Wt (lbs/ft)
5.90

(cont'd)
k2 =

2.27

B p = F cy [1 + F cy

F a3

(1/3)

/ 11.447] =

45.04

, (ADM-I Table B.4.2)

D p = (B p / 10) (B p / E) 0.5 =

0.30

, (ADM-I Table B.4.2)

S 1 = (B p - n u F cy / n y ) / (5.0 D p ) =

2.57

, (ADM-I B5.4.1)

S 2 = k 1 B p / (5.0 D p ) =

10.48

, (ADM-I B5.4.1)

F cy
b
, for
d S1

t
n
y

b
B p  1.6 D p

t
b
, for

S1   S 2
t
nu

k 2 B pE , for b t
S2

1.6b
t
nu
t

Pn
A g :c

Where

, (ADM-I Table B.4.3)

16.78

b/t=
25.920
, (ADM-I Figure B.5.2)
8.03
S 1 = (B p - n u F cy / n y ) / (1.6 D p ) =

, (ADM-I B5.4.2)

S 2 = k 1 B p / (1.6 D p ) =

, (ADM-I B5.4.2)

fa = P / A =

8.13

ksi

32.76

<
F a = Min (F a 1 , F a 2 , F a 3 ) =
[Satisfactory]

CHECK TENSION STRESS IN BENDING MOMENTS


F = P n /(A g : t ) = Min (F ty /n y , F tu / k t n u , 1.3F ty /n y , 1.42F tu / k t n u ) =
Where

kt =

1.00

f = Min (M rx / S x , M ry / S y ) =
Where

ksi, (compression in web, ADM-I B.5.4.2)

Sx =

13.20

7.27
ksi
[Satisfactory]
in, (Page V-7 to V-10)

Sy =

2.82

in, (Page V-7 to V-10)

S 1 = 1.2 (B c - F cy ) / D c =

21.31

S 2 = 1.2 C c =

78.81

, (ADM-I F.2.1)

Cb =

, (ADM-I F.1.1)

1.00

L b / (r y C b

F bx 2

Mn
S x:b

Where

0.5

)=

ksi

19.58

ksi, (tension bending, ADM-I D.1, D.2 & F.8.1.2)

F =

19.58

, (ADM-I Table A.3.3)

<

CHECK COMPRESSION STRESS IN STRONG GEOMETRIC AXIS, x - x, BENDING MOMENT


F cy
Lb
, for
d S1

r y Cb
ny

 D c Lb
B c 1.2r C
y
b

Lb 
, for
Mn
S1 
S2
18.89
F bx1

ny
S x :b
r y Cb

2
Lb t
C bS E
, for
S2
2

r y Cb

L
b
n y

1.2r y
Where

16.78

ksi

ksi, (compression in beam, ADM-I F.2.1)

, (ADM-I F.2.1)

40.00

F cy
b
, for
d S1

t
n
y

5.0 D pb
B p 

b
, for

S1   S 2
t
n

b
k 2 B pE
t S2
, for

5.0b
t
ny
t

20.65

b/t=
k1 =

7.293
0.5

, (ADM-I Figure B.5.1)


, (ADM-I Table B.4.3)

k2 =

2.04

, (ADM-I Table B.4.3)

S 1 = (B p - F cy ) / (5.1 D p ) =

6.68

, (ADM-I B5.4.1)

S 2 = k 1 B p / (5.1 D p ) =

14.97

, (ADM-I B5.4.1)

ksi, (compression in flanges, ADM-I B.5.4.1)

(cont'd)

F bx3

Mn
S x:b

Where

1.3F cy
h
, for
d S1

t
ny

h
B br  mD br

h
t
, for

S1   S 2
t
ny

k 2 B br E , for h t S
2

mh
t
ny

27.58

ksi, (compression in web, ADM-I B.5.5.1)

h/t=b/t=
28.720 , (ADM-I Figure B.5.2)
4
in
cc = co =
m=
0.65
, (ADM-I B5.5.1)
B br = 1.3 F cy [1 + F cy (1/3) / 7] =
66.76
, (ADM-I Table B.4.2)
D br = (B br / 20) (6 B br / E)

(1/3)

1.14

, (ADM-I Table B.4.2)

S 1 = (B br - 1.3 F cy ) / (m D br ) =

0.49

, (ADM-I B5.5.1)

S 2 = k 1 B br / (m D br ) =

45.11

, (ADM-I B5.5.1)

f bx = M rx / S x =

7.27

<
F bx = Min (F bx 1 , F bx 2 , F bx 3 ) =
[Satisfactory]

ksi

18.89

ksi

CHECK COMPRESSION STRESS IN WEAK GEOMETRIC AXIS, y - y, BENDING MOMENT

F by

Mn
S y :b

Where

1.3F cy
b
d
, for

t
ny

b
B br  3.5 D br
t
,

ny

S 2E

, for
2

3.5b
n y t

S1

S1 

for

b
 S2
t

22.85

ksi, (compression in web, ADM-I B.5.5.2)

b
t S2
t

b/t=
7.293
, (ADM-I Figure B.5.3)
39.10
, (ADM-I Table B.4.2)
C br = 2B br / (3 D br ) =
S 1 = (B br - 1.3 F cy ) / (3.5 D br ) =
S 2 = C br / 3.5 =

f by = M ry / S y =

10.21

5.34

11.17

, (ADM-I B5.5.2)

ksi

<
F by =
[Satisfactory]

, (ADM-I B5.5.2)

22.85

ksi

CHECK COMBINED COMPRESSION AND BENDING (ADM-I H.1)

P r M rx M ry f a f bx f by






P c M cx M cy F a F bx F by

Max

C my f by
C mx f bx
f a



Check
F a F bx 1  f a / F ex F by 1  f a / F ey

Where

Check =
C mx =

1
0.85

1.32

<
1.33
[Satisfactory]

, (1.33 if IBC/CBC 1605.3.2 apply)

Check if ASD 2005 Eq. 4.1.1-1 apply (1 = Yes, 0 = No)


C my =
0.85

F ex = S 2 E / n u (kL x /r x ) 2 =

238.32

ksi

F ey = S 2 E / n u (kL y /r y ) 2 =

128.38

ksi

CHECK SHEAR STRESS (ADM-I G)

Fs

Vn
A w: v

F ty / 3
h
, for
d S1

t
ny

1.25 D sh

Bs 

t
, for
 S2
S1 

t
n
y

h
S 2E

, for
t S2
2
t

1.25h
n y

12.25

ksi, (shear, ADM-I G.2)

(cont'd)
Where

h/t=b/t=
28.720 , (ADM-I Figure G.2.1)
0.5
0.5 (1/3)
/ 9.3] =
26.13
B s = (F cy / 3 ) [1 + (F cy / 3 )
D s = (B s / 10) (B s / E)
C s = 0.41 B s / D s =
S 1 = (B s - F cy / 3
S 2 = C s / 1.25 =

fs = V / Aw =

11.25

0.5

0.5

80.61

0.13

, (ADM-I Table B.4.2)

, (ADM-I Table B.4.2)

, (ADM-I Table B.4.2)

) / (1.25 D s ) =

35.63

64.49

, (ADM-I G.2)

ksi

<
Fs =
[Satisfactory]

, (ADM-I G.2)

12.25

ksi

PROJECT :
CLIENT :
JOB NO. :
DATE :
Member Capacity Based on Aluminum Design Manual 2010 (ASD)

Aluminum

PAGE :
DESIGN BY :
REVIEW BY :

INPUT DATA & DESIGN SUMMARY


MEMBER SIZE

D
6.625
F tu =

38

ksi

TENSILE YIELD STRESS (T5, T6, T7, T8, or T9)

F ty =

35

ksi

COMPRESSIVE YIELD STRESS (T5 to T9)

F cy =

35

ksi

TENSILE ULTIMATE STRESS (T5 to T9, Table A.3.4)

40

AXIAL COMPRESSION FORCE


P=
MAX GEOMETRIC AXIS EFFECTIVE LENGTH
GEOMETRIC AXIS BENDING MOMENT

M rx =

GEOMETRIC AXIS BENDING UNBRACED LENGTH


MAX SHEAR LOAD, ASD

kips, ASD
kL =
1.5

t
0.28

A
5.58

Ix
28.1

E
10100

Wt (lbs/ft)

ft

13.75 ft-kips, ASD

V =

30

L bx =
kips

ft

THE DESIGN IS ADEQUATE.


ANALYSIS
CHECK COMPRESSION STRESS IN AXIAL FORCE

F a1

Pn
A g :c

Where

D ckL

Bc  r
F cy

Min
,
,

nu
ny

S 2E
kL

, for
t S2
r
kL 2
n
u r


r =
kL / r =
E=
B c = F cy

for

0.5

C c = 0.41 (B c / D c ) =

Pn
A g :c

19.27

2.250
in, (Page V-28 to V-33)
8.00
10100
ksi, (ADM-I Table A.3.4)
[1 + (F cy / 2250) 0.5 ] =
39.37

D c = (B c / 10) (B c / E)

F a2

kL
 S2
r

Where

, (ADM-I Table B.4.2)

0.25

, (ADM-I Table B.4.2)

65.67

, (ADM-I Table B.4.2)

n u = : c / 0.85 =

1.941

, (ADM-I E.1, E.3-2 & E.3-3)

ny = :c =

1.65

, (ADM-I B.3-2, E.1, E.3-2 & E.3-3)

S2 = Cc =

65.67

, (ADM-I E.3-4)

F cy
, for R b d S 1

t
ny

B t  Dt R b

t
Rb

, for
 S2
S1 

t
n
u

S 2E
, for R b t S 2

2
t

R b 1 Rb
1.6nu

1
t 35 t

19.55

Rb / t =

11.300

, (ADM-I Page I-13)

k1 =

0.35

, (ADM-I Table B.4.3)

k2 =

2.27

B t = F cy [1 + F cy

/ 8.7055] =

D t = (B t / 4.5) (B t / E) (1/3) =
Ct =

141

43.19

, (ADM-I Table B.4.2)

1.56

, (ADM-I Table B.4.2)

, (ADM-VI Table 1-1)

S 1 = (B t - n u F cy / n y ) 2 / (D t ) 2 =
S2 = Ct =

ksi, (compression in curved element, ADM-I B.5.4.5)

, (ADM-I Table B.4.3)


(1/5)

141.00

1.66

, (ADM-I B5.4.5)

ksi, (compression in column, ADM-I E3)

, (ADM-I B5.4.5)

6.70

(cont'd)
fa = P / A =

7.17

<

ksi

F a = Min (F a 1 , F a 2 ) =
[Satisfactory]

CHECK TENSION STRESS IN BENDING MOMENTS


F = P n /(A g : t ) = Min (1.17F ty /n y , 1.24F tu / k t n u ) =
Where

kt =

f = M rx / S x =
Where

Sx =

1.00

, (ADM-I Table A.3.3)

19.41

ksi

8.50

[Satisfactory]
in, (Page V-28 to V-33)

<

F =

19.27

ksi

24.27

ksi, (tension bending, ADM-I D.1, D.2 & F.6.1)

24.27

ksi

24.82

ksi, (compression in beam, ADM-I F.6)

CHECK COMPRESSION STRESS IN BENDING MOMENT

F bx

Mn
S x:b

1.17 F cy
, for R b d S 1

t
n
y

1 B tb  D tb R b , for S 1  R b  S 2

t
t
n
y

2E
S

, for R b t S 2
2

1.6n u R b 1 1 Rb

t 35 t

Where

Rb / t =

11.300

, (Page I-13)

B tb = 1.5 F cy [1 + F cy

(1/5)

64.78

, (ADM-I Table B.4.2)

D tb = (B tb / 2.7) (B tb / E) (1/3) =

/ 8.7055] =

4.46

, (ADM-I Table B.4.2)

S 2 = ( B tb - B t ) 2 / ( D tb - D t ) 2 =

55.44

, (ADM-I F.6.2)

S 2 = C t = (n u B tb / n y - B t ) 2 / (n u D tb / n y - D t ) 2 =
f bx = M rx / S x =

19.41

<
F bx =
[Satisfactory]

ksi

24.82

80.24

, (ADM-I F.6.2 & ADM 2005 Eq. 3.4.12-4)

ksi

CHECK COMBINED COMPRESSION AND BENDING (ADM-I H.1)

fa
f
P r M rx


 bx

P c M cx F a F bx

Max

fa

f bx
C
mx


Check
F a F bx 1  f a / F ex

Where

1.15

<
1.33
[Satisfactory]

, (1.33 if IBC/CBC 1605.3.2 apply)

Check =
1
Check if ASD 2005 Eq. 4.1.1-1 apply (1 = Yes, 0 = No)
802.37 ksi,
C mx =
0.85
F ex = S 2 E / n u (kL x /r x ) 2 =

CHECK SHEAR STRESS (ADM-I G)

Fs

Vn
A w: v

F ty / 3
, for

ny

B s  1.25 D sh

ny

S 2E

,
1.25h 2
n y

Where

h
d S1
t

for S 1 

for

h
t S2
t

h
 S2
t

12.25

ksi, (shear, ADM-I G.2)

h/t=b/t=
23.66
, (for strong shear, Figure G.2)
B s = (F cy / 3 0.5 ) [1 + (F cy / 3 0.5 ) (1/3) / 9.3] =
26.13
, (ADM-I Table B.4.2)
D s = (B s / 10) (B s / E) 0.5 =

0.13

C s = 0.41 B s / D s =

, (ADM-I Table B.4.2)

80.61

S 1 = (B s - F cy / 3 0.5 ) / (1.25 D s ) =
S 2 = C s / 1.25 =
f s = V strong / A w =

2.26

, (ADM-I Table B.4.2)


35.63

64.49

, (ADM-I G.2)

ksi

<
Fs =
[Satisfactory]

, (ADM-I G.2)

12.25

ksi, (for strong shear)

PROJECT :
PAGE :
CLIENT :
DESIGN BY :
JOB NO. :
DATE :
REVIEW BY :
Structural Glass Design, Based on ASTM E1300 & CAN/CGSB-12.20, using Finite Element Method
INPUT DATA & DESIGN SUMMARY
GLASS PANEL SIZE

1.5
5

W=
L=

ft, (457 mm)


ft, (1524 mm)

GLASS PANEL THICKNESS


Weight =
77

t = 0.7874 in, (20 mm)


lbs, (35 kg)

CONNECTION TYPE ( 0 or 1)

, only corner pinned.

allow = 3.5
ksi,
(24 N / mm )
ALLOWABLE GLASS STRENGTH
(Annealed: 3.5 ksi, Heat-strengthened: 6.5 ksi, Tempered: 14.5 ksi - verify reqd.)
2

ALLOWABLE DEFLECTION
L / 240
( The max value suggested: L / 60 for window or curtain wall, L / 180 for stair.)
UNIFORM AREA LOAD (Perpendicular to Plane)
POINT LOAD (Including Impact Factor)

D=
P=

10
0.3

psf, ASD level


kips, ASD level

THE DESIGN IS ADEQUATE.


ANALYSIS
GLASS PROPERTIES
=
156
E=
10150
=
0.22

lbs / ft (2500 kg / m )
ksi (70 kN / mm 2 )
, Poisson's ratio

JOINT DEFLECTIONS, REACTIONS, & PLATE SECTION FORCES


kips,( Point load at Joint 9.)
P=
0.3
Joint
Number
1
2
3
4
5
6
7
8
9

in
0
0.14
0.21
0.00
0.14
0.21
0.00
0.14
0.21

R
kips
-0.09

CHECK BENDING CAPACITY


2
M n / b = allow d t / 6 =

Bending

Section
7-8
8-9
3-6
6-9

4.34

ft-k/ft

M
ft-k/ft
0.03
0.04
0.42
0.42

>

M =

0.42

ft-k/ft

[Satisfactory]
Where

d=
12
in, (1 ft)
2
2 0.5
M = (M 6-9 + M 8-9 )
=
0.42

CHECK DEFLECTION
max =
0.21
Where

in

L = Max (L , W) =

<
[Satisfactory]
60.0 in

ft-k/ft

L / 240

0.25

in

PAGE :
DESIGN BY :
REVIEW BY :

PROJECT :

CLIENT :
JOB NO. :

DATE :

Unit Conversions between U.S. Customary System & Metric System


U.S. Customary System to Metric System
W14X26

==>

Metric System to U.S. Customary System


HSS203.2X203.2X6.4

W360X39

==>

HSS8X8X1/4

Rebar #

(0.75 in)

==>

19.1

mm, diameter.

25

mm, diameter rebar,

# 7, (0.875 in)

Metal Mils

18

(0.0188 in)

==>

0.478

mm, thickness

1.15

mm, thickness,

Metal Mils 43, (0.0451 in)

Multiply

By

By

Multiply
10
20
30
40
100
1.3
4000
5
29000

kips
lbf (lbs)
ft-kips
in-lbf
psf (lbf / ft2)
ksf (kips / ft2)
psi (lbf / in2)
ksi (kips / in2)
ksi (kips / in2)

4.448
4.448
1.356
112.984
47.882
47.880
0.007
6.895
0.007

16
20
100
1
150

ft (192 in)
in
ft2
yd (3 ft)
yd3

0.305

1
20
150
145
10

lbm (lbs)
psf (lbs / ft2)
pcf (lbs / ft3)
pcf (lbf / ft3)
kips-sec2/ ft

0.454

9.807

1
1

gal water
ft3 water

8.34 lbs / gal

25.400
0.093
0.914
0.765

4.883
16.018
0.157
1488

To Obtain
44.482
88.964
40.674
4519.371

kN
N
kNm
Nmm

100
200
300
400

kN
N
kNm
Nmm

4788.159
62.244
27.579
34.474
199.948

N / m2

N / m2

GPa

1000
65
30
500
200

m
mm
m2
m
m3

1
1
10
1
115

4.877
508.000
9.290
0.914
114.683
0.454
97.651
2402.757
22.780
14882

kPa
MPa
N / mm2

kg
kg / m2
kg / m3
kN / m3
kg-s2 / m

2
9.807 m / s

0.5
100
2500
24
15000
1

0.225
0.225
0.738
0.009
0.021

kPa
MPa
N / mm2

0.021

GPa

145.038

m
mm
m2
m
m3

3.281

kg
kg / m2
kg / m3
kN / m3
kg-s2 / m

2.205

32.174

145.038
0.145

0.039
10.764
1.094
1.308

0.205
0.062
6.365
0.000672

To Obtain
22.481
44.962
221.272
3.540
20.885
1.358
4351.153
72.519
29007.548
3.281
0.039
107.643
1.094
150.414
1.102
20.481
156.071
152.769
10.080

kips
lbf (lbs)
ft-kips
in-lbf
psf (lbf / ft2)
ksf (kips / ft2)

psi (lbf / in2)


ksi (kips / in2)
ksi (kips / in2)

ft (39 in)
in
ft2
yd
yd3
lbm (lbs)
2

psf (lbs / ft )
pcf (lbs / ft3)

pcf (lbf / ft3)


kips-sec2/ ft

2
32.174 ft / sec

(386 in / sec2)

100
1
1

acre
ton

62.4 lbs / ft3


( 0C - 32) / 1.8

4047
2000

3.783 kg
28.304 kg
0

37.778 C
2
4047 m
2000 lbs

1
37
1
1

m3 water

1000 kg / m3

1.8 0C + 32

acre
ton

43560
907.180

2204.634 lbs
0
98.600 F
2
43560 ft
907 kg

Index

Software Name

Aluminum C or CS Member
Aluminum I or WF Member
Aluminum PIPE Member
Aluminum RT Member
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Anchorage
Angle
Balanced Loads
Base Plate
Base Plate
Base Plate
Base Plate
Base Plate
Base Plate
Base Plate
Base Plate
Basement Column
Basement Wall
Basement Wall
Beam Design
Beam to Wall
Bearing Wall
Bearing Wall
Bearing Wall
Bearing Wall
Bearing Wall
Bearing Wall
Bending Post
Bolt
Bolt
Bolted Stiffened End Plate
Bolted Stiffened End Plate
Bolted Stiffened End Plate
Bolts Connection
Bolts Connection
Boundary
Box Section
Brace Frame
Bracing Connection
Bracing Connection
Bresler Method
Bridge Column

Aluminum-C-CS-Capacity.xls
Aluminum-I-WF-Capacity.xls
Aluminum-PIPE-Capacity.xls
Aluminum-RT-Capacity.xls
AnchorageToConcrete.xls
AnchorageToConcrete.xls
AnchorageToConcrete.xls
AnchorageToConcrete.xls
AnchorageToConcrete.xls
AnchorageToMasonry.xls
AnchorageToMasonry.xls
AnchorageToMasonry.xls
AnchorageToMasonry.xls
AnchorageToPedestal.xls
BeamToWall.xls
EquipmentAnchorage.xls
EquipmentMounting.xls
EquipmentMounting.xls
EquipmentMounting.xls
SuspendedAnchorage.xls
AngleCapacity.xls
PileCapBalancedLoads.xls
AnchorageToConcrete.xls
AnchorageToConcrete.xls
AnchorageToConcrete.xls
AnchorageToConcrete.xls
AnchorageToConcrete.xls
BasePlate.xls
BasePlate.xls
BasePlate.xls
BasementColumn.xls
BasementConcreteWall.xls
BasementMasonryWall.xls
SMRF-ACI.xls
BeamToWall.xls
BearingWallOpening.xls
MasonryBearingWall-CBC.xls
MasonryBearingWall-CBC.xls
MasonryBearingWall-IBC.xls
MasonryBearingWall-IBC.xls
StudBearingWallFooting.xls
BendingPostAtTopWall.xls
WoodBoltConnection.xls
WoodBoltConnection.xls
BSEP-SMF.xls
BSEP-SMF.xls
BSEP-SMF.xls
BoltsConnection.xls
BoltsConnection.xls
BoundarySpringGenerator.xls
Bridge-BoxSection.xls
BraceGradeBeam.xls
BraceConnection.xls
BraceConnection.xls
ConcreteColumn.xls
Bridge-ConcreteColumn.xls

__
Page 525 of 533

Page
518
511
522
515
135
139
140
142
144
224
225
226
227
188
241
274
177
178
179
180
426
88
135
139
140
142
144
369
370
371
106
97
99
119
241
234
205
207
209
211
19
223
255
256
388
390
392
382
383
67
195
23
375
377
155
197

Index

Software Name

Buckling-Restrained Braced Frames


Buckling-Restrained Braced Frames
Buckling-Restrained Braced Frames
Cantilever
Cantilever
Cantilever
Cantilever
Channel
Chord
Circular Column
Circular Column
Circular Footing
Collector
Collector
Collector
Collector to Wall
Column above Beam
Column Design
Combined Footing
Combined Footing
Composite Beam
Composite Beam
Composite Beam
Composite Beam
Composite Beam
Composite Girder
Compressible Soil
Compressible Soil
Concrete Beam
Concrete Beam
Concrete Column
Concrete Column
Concrete Pier
Concrete Slab
Concrete Tunnel
Concrete Wall
Concrete Wall
Concrete Wall
Concrete Wall
Connection
Connection
Connection
Connection
Connection
Connection
Connection
Connection
Connection
Connection
Connection
Connection
Connection
Connection
Connection
Connection
Connection

BRBF.xls
BRBF.xls
BRBF.xls
CantileverBeam.xls
CantileverColumn.xls
CantileverFrame.xls
CompositeFloorBeamWithCantilever.xls
ChannelCapacity.xls
WoodBeam.xls
CircularColumn.xls
Punching.xls
CircularFooting.xls
CompositeCollectorBeam.xls
DragForces.xls
DragForcesforBraceFrame.xls
CollectorToWall.xls
ColumnAboveBeam.xls
SMRF-ACI.xls
CombinedFooting.xls
CombinedFooting.xls
CompositeCollectorBeam.xls
CompositeFloorBeam.xls
CompositeFloorBeam.xls
CompositeFloorBeamWithCantilever.xls
EnhancedCompositeBeam.xls
CompositeFloorGirder.xls
ConventionalSlabOnGrade.xls
PT-SlabOnGround.xls
BeamPenetration.xls
ConcreteBeam.xls
ConcreteColumn.xls
PipeConcreteColumn.xls
ConcretePier.xls
Slab.xls
ConcreteTunnel.xls
BasementConcreteWall.xls
FreeStandingWall.xls
Masonry-Concrete-RetainingWall.xls
RestrainedRetainingWall.xls
BeamConnection.xls
BeamConnection.xls
BoltsConnection.xls
BoltsConnection.xls
BraceConnection.xls
BraceConnection.xls
CollectorToWall.xls
ColumnAboveBeam.xls
Diaphragm-Ledger-CMUWall.xls
Diaphragm-Ledger-CMUWall.xls
DragConnection.xls
LagScrewsConnection.xls
MetalStuds.xls
MomentAcrossGirder.xls
ToeNail.xls
TopPlateConnection.xls
WeldConnection.xls

__
Page 526 of 533

Page
308
309
311
267
411
401
364
425
248
156
150
91
421
266
412
242
427
121
31
35
421
360
362
364
418
367
71
76
147
145
153
187
78
133
200
97
116
52
58
372
373
382
383
375
377
242
427
263
264
374
269
284
428
261
254
384

Index

Software Name

Connection
Connection
Connection
Conventional Slabs
Conventional Slabs
Corbel
Corbel
Coupling Beam
Coupling Beam
Cracked
Cracked
Deck Floor
Deck Roof
Deck Roof
Deep Beam
Deep Footing
Deformation Compatibility
Development
Development
Development
Development
Diaphragm
Diaphragm
Diaphragm
Diaphragm
Diaphragm
Diaphragm
Discontinuous
Double Joist
Drag
Drag
Drag
Drilled Cast-in-place
Eccentric Footing
Eccentrically Braced Frames
Eccentrically Braced Frames
Eccentrically Braced Frames
Eccentrically Braced Frames
Eccentrically Braced Frames
Eccentrically Braced Frames
Eccentrically Braced Frames
Eccentrically Braced Frames
Elevator
Enhanced Composite Beam
Enhanced Steel Beam
Equipment Anchorage
Equipment Anchorage
Equipment Anchorage
Equipment Anchorage
Existing Concrete Shear Wall
Expansive Soil
Expansive Soil
Exterior Metal Stud Wall
Exterior Metal Stud Wall
Family Dwellings
Family Dwellings

WeldConnection.xls
WoodBoltConnection.xls
WoodBoltConnection.xls
ConventionalSlabOnGrade.xls
ConventionalSlabOnGrade.xls
Corbel.xls
Corbel.xls
CouplingBeam.xls
CouplingBeam.xls
MasonryColumn-CBC.xls
MasonryColumn-IBC.xls
FloorDeck.xls
AxialRoofDeck.xls
RoofDeck.xls
DeepBeam.xls
DeepFooting.xls
DeformationCompatibility.xls
DevelopmentSpliceConcrete.xls
DevelopmentSpliceMasonry.xls
DevelopmentSpliceMasonry.xls
DevelopmentSpliceMasonry.xls
Diaphragm-Ledger-CMUWall.xls
Diaphragm-Ledger-CMUWall.xls
DiaphragmShear.xls
FlexibleDiaphragm.xls
FlexibleDiaphragmOpening.xls
WoodDiaphragm.xls
ColumnSupportingDiscontinuous.xls
DoubleJoist.xls
DragConnection.xls
DragForces.xls
DragForcesforBraceFrame.xls
ConcretePile.xls
EccentricFooting.xls
EBF-CBC.xls
EBF-CBC.xls
EBF-CBC.xls
EBF-CBC.xls
EBF-IBC.xls
EBF-IBC.xls
EBF-IBC.xls
EBF-IBC.xls
Elevator-DSA-OSHPD.xls
EnhancedCompositeBeam.xls
EnhancedSteelBeam.xls
EquipmentAnchorage.xls
EquipmentMounting.xls
EquipmentMounting.xls
EquipmentMounting.xls
ExistingShearWall.xls
ConventionalSlabOnGrade.xls
PT-SlabOnGround.xls
ExteriorMetalStudWall.xls
ExteriorMetalStudWall.xls
Seismic-SingleFamilyDwellings.xls
Seismic-SingleFamilyDwellings.xls

__
Page 527 of 533

Page
385
255
256
69
71
160
161
151
152
218
221
387
487
386
148
62
507
162
229
230
231
263
264
134
474
463
251
158
245
374
266
412
80
16
320
322
323
325
315
316
317
319
233
418
415
274
177
178
179
129
69
73
406
407
443
444

Index

Software Name

Family Dwellings
Fastener
Fastener
Fastener
Fastener
Fence Wall
Finite Element Method
Finite Element Method
Finite Element Method
Finite Element Method
Fixed Moment Condition
Flagpole
Flexible Diaphragm
Flexible Diaphragm
Floodway
Floor Deck
Flush Wall
Flush Wall
Flush Wall
Flush Wall
Free Standing
Free Standing
Fully Restrained Moment Connection
Girder
Girder
Girt
Grade Beam
Grade Beam
Grade Beam
Grade Beam
Ground Well
Gusset Plate
Gusset Plate
Handrail
Handrail
Horizontal Bending
Interior Wall
Interior Wall
Interior Wall
Intermediate Moment Resisting Frames
Intermediate Moment Resisting Frames
Isolated Deep Foundation
Joint Design
King Stud
Lag Screw
Lateral Force
Lateral Force
Lateral Force
Lateral Force
Lateral Force
Lateral Frame Formulas
Lateral Frame Formulas
Lateral Frame Formulas
Lateral Frame Formulas
Lateral Resisting Frame
Live Load

Seismic-SingleFamilyDwellings.xls
AnchorageToMasonry.xls
AnchorageToMasonry.xls
AnchorageToMasonry.xls
AnchorageToMasonry.xls
MasonryRetainingWall.xls
DiscontinuousShearWall.xls
ShearWallForces.xls
TwoStoryMomentFrame.xls
X-BracedFrame.xls
FixedMomentCondition.xls
Flagpole.xls
FlexibleDiaphragm.xls
FlexibleDiaphragmOpening.xls
FloodWay.xls
FloorDeck.xls
FlushWallPilaster-CBC.xls
FlushWallPilaster-CBC.xls
FlushWallPilaster-IBC.xls
FlushWallPilaster-IBC.xls
FreeStandingWall.xls
FreeStandingWall.xls
MomentAcrossGirder.xls
Bridge-ConcreteGirder.xls
GirderAtWall.xls
WindGirtDeflection.xls
BraceGradeBeam.xls
GradeBeam.xls
GradeBeam.xls
MRF-GradeBeam.xls
UnderGroundWell.xls
GussetGeometry.xls
GussetGeometry.xls
Handrail.xls
Handrail.xls
HorizontalBendingWall.xls
InteriorWallLateralForce.xls
InteriorWallLateralForce.xls
InteriorWallLateralForce.xls
OMRF-CBC.xls
OMRF-IBC.xls
ConcretePier.xls
SMRF-ACI.xls
WoodColumn.xls
LagScrewsConnection.xls
WallLateralForce-CBC.xls
WallLateralForce-CBC.xls
WallLateralForce-IBC.xls
WallLateralForce-IBC.xls
WallLateralForce-IBC.xls
LateralFrameFormulas.xls
LateralFrameFormulas.xls
LateralFrameFormulas.xls
LateralFrameFormulas.xls
BasementColumn.xls
LiveLoad.xls

__
Page 528 of 533

Page
445
224
225
226
227
49
503
501
504
505
110
61
474
463
111
387
235
236
238
240
113
116
428
192
213
506
23
36
38
27
102
379
380
451
452
228
508
509
510
328
326
78
123
249
269
449
450
446
447
448
465
466
467
468
106
460

Index

Software Name

Live Load
Live Load
Magnified Moment
Magnified Moment
Masonry Beam
Masonry Beam
Masonry Column
Masonry Column
Masonry Column
Masonry Column
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Masonry Wall
Mat
Member Capacity
Metal Beam
Metal Brace
Metal Column
Metal Joist
Metal Shear Wall
Metal Shear Wall
Metal Wall
Moment Resisting
Open Structure
Open Structure
Open Structure
Open Structure
Opening
Opening
Opening
Opening
Opening
Opening
Opening
Ordinary Moment Resisting Frames
Ordinary Moment Resisting Frames
Ordinary Concentrically Braced Frames
Ordinary Concentrically Braced Frames
Ordinary Concentrically Braced Frames
Ordinary Concentrically Braced Frames

LiveLoad.xls
LiveLoad.xls
CircularColumn.xls
ConcreteColumn.xls
MasonryBeam.xls
MasonryBeam.xls
MasonryColumn-CBC.xls
MasonryColumn-CBC.xls
MasonryColumn-IBC.xls
MasonryColumn-IBC.xls
BasementMasonryWall.xls
BearingWallOpening.xls
Elevator-DSA-OSHPD.xls
FlushWallPilaster-CBC.xls
FlushWallPilaster-CBC.xls
FlushWallPilaster-IBC.xls
FlushWallPilaster-IBC.xls
FreeStandingWall.xls
GirderAtWall.xls
HorizontalBendingWall.xls
MasonryBearingWall-CBC.xls
MasonryBearingWall-CBC.xls
MasonryBearingWall-IBC.xls
MasonryBearingWall-IBC.xls
Masonry-Concrete-RetainingWall.xls
MasonryRetainingWall.xls
MasonryShearWall-CBC.xls
MasonryShearWall-IBC.xls
RestrainedRetainingWall.xls
BoundarySpringGenerator.xls
HSS-WF-Capacity.xls
MetalStuds.xls
MetalStuds.xls
MetalStuds.xls
MetalStuds.xls
MetalShearWall.xls
MetalShearWallOpening.xls
MetalStuds.xls
MRF-GradeBeam.xls
OpenStructureWind.xls
OpenStructureWind.xls
ShadeStructureWind.xls
ShadeStructureWind.xls
ExteriorMetalStudWall.xls
MetalShearWallOpening.xls
ShearWallForces.xls
ShearWall-NewOpening.xls
ShearWallOpening.xls
ShearWallRigidity.xls
WF-Opening.xls
OMRF-CBC.xls
OMRF-IBC.xls
OCBF-CBC.xls
OCBF-CBC.xls
OCBF-IBC.xls
OCBF-IBC.xls

__
Page 529 of 533

Page
461
462
157
154
215
216
217
218
220
221
99
234
233
235
236
238
240
113
213
228
205
207
209
211
52
49
203
201
55
67
424
277
283
281
275
285
286
279
27
479
481
482
484
407
286
501
498
257
499
381
328
326
293
295
290
292

Index

Software Name

Ordinary Concrete Shear Wall


Pad Footing
Pads
Pads
Pedestal
Penetration
Perforated Shear Wall
Pilaster
Pilaster
Pilaster
Pilaster
Pile
Pile Cap
Pile Cap
Pile Cap
Pile Cap
Pipe
Piping Footing
Plain Concrete Footing
Plate Element/Shell Element
Plate Girder
Plate Girder
Pool
Post-Tensioned Concrete Floor
Post-Tensioned Concrete Floor
Post-Tensioned Concrete Floor
Post-Tensioned Concrete Floor
Prestressed
Prestressed
PT Slabs
PT Slabs
Reactions
Rectangular
Rectangular Column
Redundancy Factor
Redundancy Factor
Restrained
Restrained
Retaining Wall
Retaining Wall
Retaining Wall
Retaining Wall
Retaining Wall
Retaining Wall
Retaining Wall
Rigid Diaphragm
Rigidity
Rigidity
Roof Deck
Roof Deck
Roof Screen
Roof Screen
Rotation
Seismic Analysis
Seismic Analysis
Seismic Analysis

OrdinaryShearWall.xls
PAD.xls
GradeBeam.xls
GradeBeam.xls
AnchorageToPedestal.xls
BeamPenetration.xls
PerforatedShearWall.xls
FlushWallPilaster-CBC.xls
FlushWallPilaster-CBC.xls
FlushWallPilaster-IBC.xls
FlushWallPilaster-IBC.xls
ConcretePile.xls
PileCapBalancedLoads.xls
PileCaps.xls
PileCaps.xls
PileCaps.xls
PipeConcreteColumn.xls
FootingAtPiping.xls
PlainConcreteFooting.xls
PlateShellElement.xls
PlateGirder.xls
PlateGirder.xls
ConcretePool.xls
PT-ConcreteFloor.xls
PT-ConcreteFloor.xls
PT-ConcreteFloor.xls
PT-ConcreteFloor.xls
Bridge-BoxSection.xls
Bridge-ConcreteGirder.xls
PT-SlabOnGround.xls
PT-SlabOnGround.xls
PileCapBalancedLoads.xls
RectangularSection.xls
Punching.xls
Seismic-IBC09.xls
Seismic-IBC2006.xls
RestrainedRetainingWall.xls
RestrainedRetainingWall.xls
ConcreteRetainingWall.xls
ConcreteRetainingWall.xls
Masonry-Concrete-RetainingWall.xls
MasonryRetainingWall.xls
RestrainedRetainingWall.xls
RestrainedRetainingWall.xls
RetainingWall-DSA-OSHPD.xls
RigidDiaphragm.xls
ShearWall-NewOpening.xls
ShearWallRigidity.xls
AxialRoofDeck.xls
RoofDeck.xls
RoofScreenWind.xls
RoofScreenWind.xls
RigidDiaphragm.xls
Seismic-IBC09.xls
Seismic-IBC09.xls
Seismic-IBC2006.xls

__
Page 530 of 533

Page
126
12
36
38
188
147
259
235
236
238
240
80
88
82
84
86
187
89
68
191
347
352
181
169
171
173
175
195
192
73
76
88
335
149
441
491
55
58
40
43
52
49
55
58
46
469
498
499
487
386
485
486
469
438
440
488

Index

Software Name

Seismic Analysis
Seismic Analysis
Seismic Analysis
Seismic Analysis
Seismic Design
Shade
Shade
Shear Friction
Shear Friction
Shear Wall
Shear Wall
Shear Wall
Shear Wall
Shear Wall
Shear Wall
Shear Wall
Shear Wall
Shear Wall
Shear Wall
Shear Wall
Shear Wall
Shear Wall
Shear Wall
Shear Wall Footing
Sign
Sign
Sign
Simply Supported
Simply Supported
Simply Supported
Slab Punching
Slab Punching
Snow
Snow
Snow
Snow
Soil Pressure
Solar Panel
Solar Panel
Solar Panels
Solar Panels
Special Concentrically Braced Frames
Special Concentrically Braced Frames
Special Concentrically Braced Frames
Special Concentrically Braced Frames
Special Concentrically Braced Frames
Special Concentrically Braced Frames
Special Concentrically Braced Frames
Special Concentrically Braced Frames
Special Concrete Shear Wall
Special Moment Resisting Frame
Special Moment Resisting Frame
Special Moment Resisting Frame
Special Moment Resisting Frames
Special Moment Resisting Frames
Special Plate Shear Wall

Seismic-IBC2006.xls
Seismic-SingleFamilyDwellings.xls
Seismic-SingleFamilyDwellings.xls
Seismic-SingleFamilyDwellings.xls
CombinedFooting.xls
ShadeStructureWind.xls
ShadeStructureWind.xls
Friction.xls
Friction.xls
DiscontinuousShearWall.xls
ExistingShearWall.xls
MasonryShearWall-CBC.xls
MasonryShearWall-IBC.xls
MetalShearWall.xls
OrdinaryShearWall.xls
ShearWallForces.xls
ShearWall-NewOpening.xls
ShearWallOpening.xls
ShearWallRigidity.xls
SpecialShearWall-CBC.xls
SpecialShearWall-IBC.xls
WallFooting.xls
WoodShearWall.xls
WallFooting.xls
Sign.xls
Sign.xls
SignWind.xls
BeamWithTorsion.xls
BeamWithTorsion.xls
TripleW-Shapes.xls
Punching.xls
Punching.xls
Snow.xls
Snow.xls
Snow.xls
Snow.xls
IrregularFootingSoilPressure.xls
Wind-ASCE7-05.xls
Wind-ASCE7-05.xls
OpenStructureWind.xls
OpenStructureWind.xls
SCBF-CBC.xls
SCBF-CBC.xls
SCBF-CBC.xls
SCBF-CBC.xls
SCBF-IBC.xls
SCBF-IBC.xls
SCBF-IBC.xls
SCBF-IBC.xls
SpecialShearWall-CBC.xls
SMRF-ACI.xls
SMRF-ACI.xls
SMRF-ACI.xls
SMRF-CBC.xls
SMRF-IBC.xls
SPSW.xls

__
Page 531 of 533

Page
490
443
444
445
35
482
484
167
168
503
129
203
201
285
126
501
498
257
499
127
124
21
250
21
453
454
455
342
344
336
149
150
456
457
458
459
66
493
495
479
481
302
304
306
307
296
298
300
301
127
119
121
123
332
330
313

Index

Software Name

Special Reinforced Concrete Shear Wall


Spectrum
Spectrum
Splice
Splice
Splice
Splice
Splice
Stair
Stair
Steel Beam
Steel Beam
Steel Beam
Steel Beam
Steel Beam
Steel Beam
Steel Column
Steel Column
Steel Column
Steel Member Capacity
Steel Member Capacity
Steel Member Capacity
Stud Footing
Stud Wall
Stud Wall
Subdiaphragm
Subdiaphragm
Suspended Anchorage
Tables
Tables
Tables
Tables
Tank Footing
Tank Footing
Temporary
Tilt-up Panel
Toe-Nail
Top Plate
Torsion
Triple
Truss
Truss
Tunnel
Two Story Moment Frame
Two-Way Slab
Two-Way Slab
Uncracked
Uncracked
Unit Conversions between
Wall Lateral Force
Wall Lateral Force
Wall Lateral Force
Wall Lateral Force
Wall Lateral Force
Wall Pier
Wall Stud

SpecialShearWall-IBC.xls
Seismic-IBC09.xls
Seismic-IBC2006.xls
BeamSplice.xls
DevelopmentSpliceConcrete.xls
DevelopmentSpliceMasonry.xls
DevelopmentSpliceMasonry.xls
DevelopmentSpliceMasonry.xls
SteelStair.xls
SteelStair.xls
BeamGravity.xls
BeamGravity.xls
BeamWithTorsion.xls
BeamWithTorsion.xls
EnhancedSteelBeam.xls
WF-Opening.xls
CantileverColumn.xls
SteelColumn.xls
SteelColumn.xls
AngleCapacity.xls
ChannelCapacity.xls
HSS-WF-Capacity.xls
StudBearingWallFooting.xls
ExteriorMetalStudWall.xls
ExteriorMetalStudWall.xls
Subdiaphragm.xls
Subdiaphragm.xls
SuspendedAnchorage.xls
DevelopmentSpliceConcrete.xls
DevelopmentSpliceMasonry.xls
WoodTables.xls
WoodTables.xls
TankFooting.xls
TemporaryFootingforRectangularTank.xls
TemporaryFootingforRectangularTank.xls
TiltupPanel.xls
ToeNail.xls
TopPlateConnection.xls
HSS-Torsion.xls
TripleW-Shapes.xls
Truss-Metal.xls
Truss-Wood.xls
ConcreteTunnel.xls
TwoStoryMomentFrame.xls
TwoWaySlab.xls
TwoWaySlab.xls
MasonryColumn-CBC.xls
MasonryColumn-IBC.xls
UnitConversion.xls
WallLateralForce-CBC.xls
WallLateralForce-CBC.xls
WallLateralForce-IBC.xls
WallLateralForce-IBC.xls
WallLateralForce-IBC.xls
WallPier.xls
WoodColumn.xls

__
Page 532 of 533

Page
124
442
492
430
163
229
230
231
394
396
338
340
342
344
415
381
411
404
405
426
425
424
19
406
407
252
253
180
164
232
272
273
94
101
101
131
261
254
346
336
413
270
200
504
183
185
217
220
524
449
450
446
447
448
132
249

Index

Software Name

Page

Water
Web Tapered Frame
Web Tapered Girder
Web Tapered Girder
Web-Tapered Cantilever Frame
Weld Connection
Weld Connection
Wind Analysi
Wind Analysis
Wind Analysis
Wind Analysis
Wind Analysis
Wind Analysis
Wind Analysis
Wind Analysis
Wind Analysis
Wind Analysis
Wind Analysis
Wind Analysis
Wind Analysis
Wood Beam
Wood Beam
Wood Beam
Wood Column
Wood Joist
Wood Joist
Wood Post
Wood Post
Wood Post
X-Braced Frame
Z-Purlins

ConcreteRetainingWall.xls
WebTaperedFrame.xls
WebTaperedGirder.xls
WebTaperedGirder.xls
CantileverFrame.xls
WeldConnection.xls
WeldConnection.xls
WindGirtDeflection.xls
OpenStructureWind.xls
OpenStructureWind.xls
RoofScreenWind.xls
RoofScreenWind.xls
ShadeStructureWind.xls
ShadeStructureWind.xls
SignWind.xls
Wind-ASCE7-02.xls
Wind-ASCE7-02.xls
Wind-ASCE7-05.xls
Wind-ASCE7-05.xls
Wind-IR16-7.xls
CantileverBeam.xls
WoodBeam.xls
WoodTables.xls
WoodTables.xls
DoubleJoist.xls
WoodJoist.xls
WoodColumn.xls
WoodTables.xls
WoodTables.xls
X-BracedFrame.xls
Metal-Z-Purlins.xls

40
398
356
358
401
384
385
506
479
481
485
486
482
484
455
431
433
493
495
436
267
247
273
272
245
243
249
272
273
505
288

__
Page 533 of 533

También podría gustarte