Municipal corporations in many cities supply water during early morning hours. So, you have to wake up early,
just to switch on your motor pump and wait till your water tank is filled up. Further, there is no control for
overflow of the tank. Many times you come to know of your overflowing tank only when your neighbour informs
you.
Here is a low-cost and simple automatic water pump controller circuit (Fig. 1) to avoid the aforesaid problem.
You just have to set your quartz alarm clock (connected to this system) at the appropriate time of water supply.
Keep the clock nearby your sleeping bed and switch on the circuit before going to sleep. In the morning, as the
alarm rings, you can switch off the alarm and, if you like, go to sleep again. The controller system will
automatically switch on the pump motor immediately at the predetermined time. When the overhead tank is full,
the pump motor will get switched off automatically, preventing overflow of the tank. The controller system works
with a water-level sensor assembly. The sensor assembly has to be fixed up properly inside your overhead
water tank.

You can assemble a simple water-level sensor (Fig. 2) at home. Take an empty cylindrical plastic vial having
outer diameter smaller than 1.3 cm (0.5 inch), which is commonly used for dispensing medicines. Make it
opaque by pasting a piece of black paper or PVC tape on its inner side. Fix up the vials lid firmly with a
suitable material to make it airtight.
Now take a 15.2cm (6-inch) piece of opaque PVC conduit pipe having inner diameter of 1.3 cm (0.5 inch).

Ensure that the vial can freely slide along the axis inside the conduit pipe; else use a PVC pipe having larger
inner diameter. Drill two through-holes (of diameter 3.5 mm) along the diameter of the PVC pipe, at least 15 mm
away from each end. Also drill two 5mm dia. through-holes along the diameter of the PVC pipe, 25-30 mm
away from one end.
Insert the airtight plastic vial inside the PVC pipe and fix up two screws (M3x25mm) through 3.5mm dia. holes
with suitable M3 nuts near the ends. These screws will restrict sliding of the vial within the PVC pipe.
Then fix up a 5mm red LED perpendicular to 5mm dia. hole, on the outer surface of PVC pipe, using suitable
adhesive like M-seal. Also, opposite to this, fix up a light-dependent resistor (LDR) in similar way as shown in
Fig. 1. Ensure that both the LDR and the LED are firmly placed outside the PVC pipe and they dont interrupt
movement of the vial inside the PVC pipe. Also ensure that the maximum light produced by the LED falls on the
surface of the LDR through 5mm dia. holes along the diameter of the PVC pipe. Then plug the open ends of
PVC pipe with dark-coloured (preferably black) sponge pieces, to avoid ambient light entering inside the pipe.

Solder the leads of LDR and LED with connecting wires of required length, according to the location of your
overhead water tank. Then fix up this water-level sensor assembly vertically at a suitable height along the inner
wall of the overhead water tank, as shown in Fig. 3.
Remove 1.5V (AA size) battery from the quartz alarm clock. Carefully open the back lid of the clock using a
small screwdriver. Solder a braided pick-up wire parallel to the connected points of your alarm buzzer (clock).
Make a small hole on the back lid of the clock and pull out free ends of the pick-up wire through this hole. Then,
carefully fix up the back lid in proper position, without disturbing any mechanical part of the clock. Solder the
free ends of pick-up wire on the PCB at input terminals. This pick-up wire will provide trigger pulses from the
alarm clock to water pump motor controller system. Then set the time and place the battery in alarm clock.
As the alarm rings, trigger pulses appear at the input of the water pump motor controller circuit shown in Fig. 1.
A low-pass filter is connected at the input to avoid false triggering of the circuit due to excessive EMI produced
by the pump motor and the relay contacts. Timer LM555 (IC1) is configured as a monostable multivibrator. The
voltage at its output (at pin 3) goes high immediately after receiving trigger pulses (at pin 2), and it remains in
this state for about five seconds, as set by the values of R3 (47k) and C3 (100, 25V). Diode D1 gets forward
biased and sufficient base current flows through R4 and R5 to drive transistor T3 into saturation. A free
wheeling diode (D2) is used to protect transistor T3 from the reverse current caused by self-induction of the
relay coil (RL1).
Transistor T3 immediately switches on the relay. This, in turn, switches on the pump motor by the relay and at
the same time the LED is turned on. The water is pumped by the motor and starts filling up the overhead water
tank from the underground reservoir.

The light produced by LED continuously falls upon the LDR. This causes a decrease in the resistance value of
the LDR and the base of transistor T2 (BC547) gets a high voltage (about 10V DC), which results in conduction
of transistor T2. Since transistor T2 is biased as an emitter follower, the emitter voltage also becomes high. Due
to this voltage feed, transistor T3 (SL100) remains in saturation.

Thus, once the circuit is triggered from the output of IC1, it will stay continuously on even when the input is
withdrawn. As such, the pump motor will continuously remain on through the relay contact. (Note. Reflection of
light from any moving/still object near the LDR affects the proper functioning (latching) of the circuit. The value
of VR1 (20k) has to be chosen for proper functioning of the circuit and according to the amount of light received
in your circuit from the surroundings.)
As the water level in the overhead tank rises, the empty vial floating along the water level inside the PVC pipe
also goes up. When the water level reaches the desired level, the floating vial interrupts the path of light falling
on the surface of LDR. Thus, the resistance of LDR increases sharply, resulting in voltage reduction at the base
of transistor T2. Hence voltage at the emitter of T2 also goes low, which reduces the base current of transistor
T3. This pulls T3 into cut-off region and both the LED and the relay are switched off. Ultimately, the AC supply
via the relay to the pump motor is also cut off and the motor stops.
The circuit (excluding pump motor, alarm clock, and sensor assembly) costs around Rs 80.