Documentos de Académico
Documentos de Profesional
Documentos de Cultura
PRIODO
2006-II
______________________________________________________________________
INGENIERIA
MECANICA
TEMA:
PERFIL TCNICO-ECONMICO DE DISEO DE UNA
CENTRAL TERMOELCTRICA DE 115 MW EN BASE A
TURBINAS A GAS
Profesores
Integrantes
20014529C
20010094B
19992102G
20010050E
20004524I
PRIODO
2006-II
______________________________________________________________________
2006
INDICE
1. INTRODUCCIN....................................................................................................03
2. OBJETIVO GENERAL............................................................................................04
3. OBJETIVOS ESPECFICOS...................................................................................04
4. ANTECEDENTES...................................................................................................04
4.1. GAS NATURAL..........................................................................................................04
4.2. MERCADO DEMANDA...............................................................................................08
4.2.1. POTENCIA INSTALADA (POR TIPO DE ORIGEN Y SERVICIO).................................10
4.2.2. POTENCIA EFECTIVA (POR TIPO DE ORIGEN Y SERVICIO)...................................10
4.2.3. EVALUACIN DE LA MXIMA DEMANDA............................................................11
4.2.4. PROYECCIN AL 2010.........................................................................................12
5. CLCULO DE LOS PARMETROS TERMODINMICOS................................14
5.1. ANLISIS DEL CICLO ABIETO SIN CONSIDERAR EFICIENCIA......................................14
5.1.1. INTRODUCCIN Y OBSERVACIONES......................................................................14
5.1.2. CONDICIONES DE OPERACIN..............................................................................16
5.1.3. CLCULOS...........................................................................................................16
5.2. ANLISIS DEL CICLO ABIETO CONSIDERANDO EFICIENCIAS.....................................18
5.2.1. INTRODUCCIN Y CONSIDERACIONES.................................................................18
5.2.2. CONDICIONES DE OPERACIN.............................................................................20
5.2.3. CLCULOS...........................................................................................................20
6. ASPECTO ECONMICO........................................................................................23
6.1. COSTO DE INVERSIN..............................................................................................23
6.2. ANUALIZACIN COSTOS FIJOS..................................................................................24
PRIODO
2006-II
______________________________________________________________________
PRIODO
2006-II
______________________________________________________________________
1. INTRODUCCIN
Una central elctrica es, esencialmente, una instalacin que emplea en determinada
cantidad una fuente de energa primaria para hacer girar (mediante agua, vapor o gas)
las paletas de una turbina que, a su vez, hace girar una gran bobina en el interior de un
campo magntico, generando as electricidad. Este principio es comn al
funcionamiento de la prctica totalidad de las centrales elctricas existente en el mundo,
salvo el caso de las instalaciones de tipo fotovoltico.
Las centrales termoelctricas tienen casi todas el mismo funcionamiento, lo que las
diferencia principalmente es el tipo de turbina que utiliza, tenemos la turbina de vapor y
la turbina de gas.
El funcionamiento de las centrales termoelctricas clsicas con turbinas de vapor,
consiste en la combustin de combustibles fsiles (carbn, petrleo, residual, gas) en
una caldera, que provoca la generacin de una energa calorfica que vaporiza el agua
que circula por una serie de conductos. Este vapor de agua es el agente que acciona las
palas de la turbina, convirtiendo la energa calorfica en energa mecnica, la cual se
traduce en torque al eje y posteriormente en energa elctrica a travs de los alternadores
Para el funcionamiento de las centrales termoelctricas con turbinas de gas, tenemos la
posibilidad de utilizar en ciclo abierto o en ciclo combinado. En el ciclo abierto de una
unidad motriz de turbina de gas, el aire que entra al compresor aumentando la presin;
luego pasa al combustor (o cmara de combustin), donde se efecta la ignicin o
quema del combustible, y este proceso eleva la temperatura de los gases producto de la
combustin, los cuales entran luego a la turbina. Por ltimo, tales gases salen de esta
mquina y escapan a la atmsfera.
En el presente trabajo monogrfico realizaremos un perfil tcnico econmico de una
Central Termoelctrica de 120 MW que trabaja con turbina a gas natural, ya que el gas
natural es uno de los combustibles que recientemente est presente en nuestro mercado
y con grandes ventajas como la reduccin del efecto invernadero y sobre todo en el
aspecto econmico con respecto a los dems combustibles convencionales.
PRIODO
2006-II
______________________________________________________________________
2. OBJETIVO GENERAL:
El objetivo del presente informe es el realizar el diseo de una central termoelctrica de
120 MW con ciclo simple, usando el gas natural como combustible.
3. OBJETIVOS ESPECFICOS:
-
4. ANTECEDENTES:
4.1. GAS NATURAL:
El gas natural es un combustible fsil formado por un conjunto de hidrocarburos que, en
condiciones de reservorio, se encuentra en estado gaseoso o en disolucin de petrleo.
Se encuentra en la naturaleza como gas natural asociado cuando est acompaado de
petrleo y como gas natural no asociado cuando no esta acompaado de petrleo, slo
por pequeas cantidades de otros hidrocarburos o gases.
PRIODO
2006-II
______________________________________________________________________
La composicin del gas natural incluye variedad de hidrocarburos gaseosos, con
predominio del metano, por sobre el 90%, y en proporciones menores etano, propano,
butano, pentano y pequeas proporciones de gases inertes como dixido de carbono y
nitrgeno. La composicin del gas vara segn el yacimiento.
Componente
Metano
Etano
Propano
Butano
Pentano
Hexano
Nitrgeno
Gas Carbnico
Nomenclatura
CH4
C2H4
C3H8
C4H10
C5H12
C6H14
N2
CO2
Composicin (%)
95,08
2,14
0,29
0,11
0,04
0,01
1,94
0,39
Estado Natural
Gas
Gas
Gas licuable (GLP)
Gas licuable (GLP)
lquido
lquido
Gas
Gas
PRIODO
2006-II
______________________________________________________________________
Densidad Relativa : 0,65
Poder Calorfico : 9.032 kcal./m3
Cp (presin Cte) : 8.57 cal/mol.C
Cv (volumen Cte) : 6.56 cal/mol.C
El gas natural est presente por todo el mundo, ya sea en los depsitos situados en las
profundidades de la superficie terrestre, o en los ocanos. Las napas de gas pueden
formarse encima de los depsitos de petrleo bruto, o estar atrapadas en el seno de las
rocas porosas. El gas es llamado "asociado" cuando se encuentra en presencia de
petrleo bruto y "no asociado" cuando se encuentra solo.
A una presin atmosfrica normal, si el gas natural se enfra a una temperatura de 161C aproximadamente, se condensa bajo la forma de un lquido llamado gas natural
licuado (GNL). Un volumen de este lquido ocupa casi 600 veces menos espacio que el
gas natural y es dos veces menos pesado que el agua (45% aproximadamente). Es
inodoro, incoloro, no es corrosivo ni txico .Cuando se evapora se quema solamente en
concentraciones del % al 15% mezclado con el aire. Ni el GNL ni su vapor pueden
explotar al aire libre. Puesto que el gas natural licuado ocupa menos espacio, el gas
natural se lica para facilitar su transporte y almacenaje.
El gas natural es considerado como un combustible limpio. Bajo su forma
comercializada, casi no contiene azufre y virtualmente no genera dixidos de azufre
(SO2). Sus emisiones de xidos de nitrgeno (No) son menores a las generadas por el
petrleo y el carbn. Las emisiones de dixido de carbono (CO2) son inferiores a la de
otros combustibles fsiles (segn Eurogas emite 40 a 50% menos que el carbn y 25 a
30% menos que el petrleo).
En el Per existe una fuente importante de Gas Natural en Camisea (Cuzco), por ello en
el presente trabajo se quiere aprovechar dicha fuente, debido a las explicaciones
anteriores: Poder Calorfico, combustible limpio (ecolgico), econmico.
PRIODO
2006-II
______________________________________________________________________
PRIODO
2006-II
______________________________________________________________________
PRIODO
2006-II
______________________________________________________________________
La Central Termoelctrica a gas entrar a tallar en horas puntas en las
pocas de avenida, donde casi gran parte del diagrama de carga es cubierta por las
centrales hidroelctricas, luego entran las centrales trmicas a carbn debido a su bajo
costo marginal, de all las centrales termoelctricas a gas usando Gas Natural (GN)
como combustible. De ser necesaria que se aumente la demanda en el SEIN, entonces
entran a actuar las centrales termoelctricas a vapor usando residual como combustible
y al final las centrales termoelctricas de grupo electrgeno (Diesel) y las centrales
termoelctricas a gas usando Diesel debido a su altsimo costo marginal. En el siguiente
grfico ocurrido el 16 de Diciembre del 2003 (da de mxima demanda), se puede
apreciar lo expresado anteriormente.
PRIODO
2006-II
______________________________________________________________________
Variacin
Media
INDICADORES
1995
1996
1997
1998
1999
2000
2001
2002
2003
4 462
4 663
5 192
5 515
5 742
6 066
5 907
5 936
5 970
6 016
Hidrulica (%)
56
53
48
47
47
47
50
50
51
51
Trmica (%)
44
47
52
53
53
53
50
50
49
49
SICN (%)
63
63
66
66
65
65
SIS (%)
14
14
15
14
15
16
4 075
4 003
4 581
4 782
5 116
5 555
5 387
5 396
5 422
5 418
Hidrulica (%)
61
55
48
44
45
48
51
51
51
52
Trmica (%)
39
45
52
56
55
52
49
49
49
48
SICN (%)
70
63
66
67
66
65
SIS (%)
16
24
15
13
15
17
84
85
85
85
2004 1995/2004
3.4%
Por Sistemas
3.2%
Por Sistemas
SEIN **(%)
Aislados (%)
MXIMA DEMANDA DEL SEIN (MW)
NMERO DE CLIENTES
15
13
19
20
19
17
16
15
15
15
2 052
2 025
2 401
2 521
2 580
2 621
2 792
2 908
2 965
3 131
4.8%
2491835 2775713 2964315 3057320 3217058 3352209 3462851 3614484 3727266 3860515
5.0%
Generacin
Mercado elctrico
Ao
Total
1 995
4 461.7
2 479.4
1 982.3
0.3
1 996
4 662.6
2 492.7
2 169.6
1 997
5 192.5
2 513.0
2 679.3
1 998
5 515.3
2 572.1
1 999
5 742.4
2 673.3
2 000
6 066.2
2 001
5 906.7
2 002
2 003
Total
Uso propio
Hidrulica
Trmica
Elica
3 185.7
2 190.0
995.7
0.3
0.3
3 352.9
2 200.2
1 152.4
0.3
4 325.0
2 411.5
1 913.3
2 943.0
0.7
4 632.3
2 467.4
3 068.4
0.7
4 828.2
2 587.1
2 856.8
3 208.7
0.7
5 148.9
2 966.3
2 939.7
0.7
5 050.8
5 935.5
2 996.5
2 938.4
0.7
5 970.1
3 032.3
2 937.1
0.7
10
Total
Hidrulica
Trmica
289.4
986.6
0.3
276.0
292.5
1 017.2
0.3
101.5
766.0
2 164.6
0.7
309.7
104.6
778.4
2 240.4
0.7
867.5
86.2
828.0
2 779.3
2 368.9
0.7
883.0
77.6
839.8
2 889.4
2 160.7
0.7
914.2
76.9
779.0
5 068.1
2 917.6
2 149.7
0.7
917.3
78.9
788.6
5 095.1
2 946.8
2 147.6
0.7
855.9
85.5
789.5
PRIODO
2006-II
______________________________________________________________________
2 004
867.5
6 016.3
3 055.9
2 959.8
5 096.0
2 969.1
2 126.3
875.0
86.8
833.5
920.3
Incr. 04/03
1%
1%
1%
0%
1%
-1%
5%
2%
6%
Incr. 04/95
35%
23%
49%
60%
36%
114%
-28%
-70%
-16%
Total
Hidrulica
Trmic
1 995
4 075.4
2 474.9
a
1 600.5
1 996
4 003.2
2 201.9
1 801.1
1 997
4 581.0
2 210.9
2 369.9
1 998
4 781.6
2 116.9
2 664.5
1 999
5 116.2
2 318.1
2 797.3
2 000
5 554.8
2 650.9
2 903.3
2 001
5 387.2
2 744.5
2 642.0
2 002
5 395.7
2 775.3
2 619.7
2 003
5 421.8
2 790.3
2 630.8
2 004
Incr. 04/03
5 418.0
0%
2 815.0
1%
2 602.3
-1%
Incr. 04/95
33%
14%
63%
Mercado elctrico
Elica
0.3
0.3
0.3
0.7
0.7
0.7
0.7
0.7
0.7
Total
Uso propio
3 195.4
2 205.9
989.5
2 879.5
1 924.9
954.4
3 826.8
2 120.2
1 706.4
4 020.9
2 022.9
1 997.6
4 317.9
2 242.6
2 074.6
4 775.9
2 575.9
2 199.3
4 642.1
2 674.8
1 966.5
4 657.8
2 702.9
1 954.3
4 686.4
2 720.2
1 965.5
4 657.3
-1%
2 747.3
1%
1 909.3
-3%
46%
25%
93%
0.3
0.3
0.3
0.7
0.7
0.7
0.7
0.7
0.7
11
Incr. Anual
0.0
-1.3
18.6
5.0
2.3
1.6
6.5
4.2
2.0
5.6
Total
Hidrulica
Trmica
880.0
269.0
611.0
1 123.7
277.0
846.7
754.2
90.7
663.5
760.8
94.0
666.9
798.2
75.5
722.7
778.9
75.0
703.9
745.1
69.7
675.4
737.8
72.4
665.4
735.4
70.0
665.4
760.6
3%
67.7
-3%
692.9
4%
-14%
-75%
13%
PRIODO
2006-II
______________________________________________________________________
2005
63.2
3305
12
5.6
PRIODO
2006-II
______________________________________________________________________
4.2.4. PROYECCIN AL 2010:
Usando la tabla anterior y extrapolando hasta el 2010, tenemos la siguiente curva:
13
PRIODO
2006-II
______________________________________________________________________
En esta curva podemos apreciar que el ascenso es casi linealmente por lo que podemos
darle una tendencia lineal para nuestros respectivos clculos.
Segn OSINERG en su Boletn Mensual de la Evaluacin de la Operacin de SEIN de
Setiembre http://www.osinerg.gob.pe/osinerg/repoelec/BoletinMensualSEINSetiembre2006.pdf nos
dice que la potencia mxima que se lleg en el 2006 (en setiembre an esta la Mxima
Demanda) a los 3 395,55 MW el da 27 a las 19:30 horas. Si nos damos cuenta en la
grfica en el ao 2006 la curva tiene una Mxima Demanda de 3396,12 MW. Este valor
coincide con la potencia registrada, por lo que nos da un factor de confiabilidad.
Para el ao 2010 se obtendr una Mxima Demanda de 3882,20 MW lo que quiere decir
que va a tener una tasa de crecimiento de 4.72%
Pfinal Pactual i 1
3882,20 3305 i 1
i 4.72%
Mxima Demanda
3396
3518
3639
3761
3882
MW anuales
91.1
121.5
121.5
121.5
121.5
14
PRIODO
2006-II
______________________________________________________________________
5.1. ANLISIS DEL CICLO ABIETO SIN CONSIDERAR EFICIENCIAS:
5.1.1. INTRODUCCIN Y OBSERVACIONES
En el ciclo abierto de una unidad motriz de turbina de gas, el aire que entra al compresor
aumenta de presin; luego pasa al combustor (o cmara de combustin), donde se
efecta la ignicin o quema del combustible, y este proceso eleva la temperatura de los
gases producto de la combustin, los cuales entran luego a la turbina. Por ltimo, tales
gases salen de esta mquina y escapan a la atmsfera.
15
PRIODO
2006-II
______________________________________________________________________
combustin, constituye la sustancia operante o de trabajo. Para analizar
este ciclo de potencia debemos emplear las propiedades de cada fluido. Cuando se trata
de aire se recurre a las tablas de aire, pero si no se dispone de este medio, se recurre
entonces a ley del gas ideal. Al considerar los productos de la combustin podemos
utilizar las tablas de 400% de aire terico, o bien la ley del gas ideal. Los calores
especficos del aire y de los productos de combustin son ligeramente distintos, y el
calor especfico de estos ltimos es mayor que el del aire.
Analicemos la cmara de combustin para ver por que 400% de aire terico constituye
un buen sustento cuando se evalan los productos de combustin.
Parte del aire pasa rodeando al combustor, enfra las paredes metlicas y se mezcla con
los productos de combustin de la parte de salida de la cmara.
16
PRIODO
2006-II
______________________________________________________________________
Potencia de Planta
115 MW
Presin atmosfrica
P1 = 100 kPa
Temperatura ambiente
T1 = 293 K (20C)
Relacin de compresin
= 15.5
5.1.3. CLCULOS:
Para los clculos asumiremos:
-
Pr1 = 1.0403
Clculo de T2
En el compresor vemos que se trata de un sistema abierto, entonces aplicando la 1ra Ley
de Termodinmica:
Clculo de T3 y T4
17
PRIODO
2006-II
______________________________________________________________________
La cmara de combustin adiabtica constituye el siguiente elemento del
ciclo, tambin es un sistema abierto, entonces:
627.375+0.015*53200= 1.015 h3
h3 = 1404.31 kJ/kg
Pr3 = 266
T3 = 1300 K
Pr4 Pr3
h4 = 690 kJ/kg
T4 = 670 K
18
PRIODO
2006-II
______________________________________________________________________
ma(1+0.015)( 1404.31) = ma(627.375 -294.32 )+120000+ma(1+0.015)
( 690)
ma = 306.146 kg/s
Clculo de WT y WC
Luego:
WT = ma(1 + rc/a)(h3 h4) = 221.963 MW
WC = -ma (h2 h1) = 101.963 MW
Clculo de la eficiencia trmica ( t)
La eficiencia trmica ser:
t
WN
WT WC
120000
QENT
m a rr / a H GN 306.146 0.015 53200
t = 0.491 = 49.1 %
Clculo de flujo de combustible (mc)
Como:
mc = 0.015 ma = 0.015 (306.146)
mc = 4.592 kg/s = 16531.2kg/hr
Clculo del consumo especfico (ge)
ge
mc 16531.2
kg
0.1378
WN
120000
kW hr
ge = 0.1378 kg/kW-hr
19
PRIODO
2006-II
______________________________________________________________________
Sin embargo, dado que las cadas de presin por rozamiento son fuentes de
irreversibilidad menos significativas. La transferencia de calor entre los componentes de
la central trmica y el ambiente supone prdidas. Pero son normalmente de importancia
secundaria y tambin se desprecia en el anlisis.
Cuando el efecto de las irreversibilidades en la turbina y el compresor se hace ms
pronunciado, el trabajo desarrollado por la turbina decrece y el trajo que entra en el
compresor crece, resultando un acusado descenso en el trabajo neto de la central
trmica; entonces para que la plantea produzca un cantidad apreciable de trabajo se
necesitan altas eficiencias en la turbina y compresor. Despus de dcadas de desarrollo,
se pueden conseguir rendimientos del 80 al 90% para turbinas y compresores en
centrales trmicos con turbinas a gas.
h3 h4
h3 h4 S
.......(1)
20
h2 S h1
.........(2)
h2 h1
PRIODO
2006-II
______________________________________________________________________
Potencia de Planta
115 MW
Presin atmosfrica
P1 = 100 kPa
Temperatura ambiente
T1 = 293 K (20C)
Relacin de compresin
= 14
c = 0.85
Eficiencia de la turbina
turb = 0.87
5.2.3. CLCULOS:
De las condiciones de operacin: T1 = 293 K
h1 =294.32 kJ/kg
Pr1 = 1.0403
Clculo de T2 y h2
En el compresor:
Pr2S = Pr1() = (1.0403)(14) = 14.5642
h2 = 627.375 kJ/kg
T2S = 615 K
De (2):
627.375 294.32
h2 294.32
h2 = 686.15 kJ/kg
T2 = 670 K
Clculo de T3 , h3 , T4 , h4
En la combustin: haciendo balance de energa
21
PRIODO
2006-II
______________________________________________________________________
ENERGIA ENTRANTE = ENERGIA SALIENTE
mah2 + mcHGN K = (ma + mc) h3
h2 + rc/aHGNK = (1 + rc/a) h3
Donde K = eficiencia de combustin = 0.9
Reemplazando datos:
686.15+0.015*53200*0.9 = 1.015 h3
h3 = 1383.6 kJ/kg
Pr3 = 258
T3 = 1280 K
En la turbina:
1
1
258
18.429
14
Pr4 S Pr3
Ahora de:
tur 0.87
h3 h4
1383.6 h4
h3 h4 S 1383.6 655.324
h4 = 750 kJ/kg
T4 = 730 K
22
PRIODO
2006-II
______________________________________________________________________
ENERGIA ENTRANTE = ENERGIA SALIENTE
ma (1 + rC/A) h3 = WC + WN + ma (1 + rC/A) h4
Pero:
WC = ma (h2 h1)
WN= 120 MW = 120000kW
ma = 477.566 kg/s
Clculo de WT y WC
Luego:
WT = ma(1 + rc/a)(h3 h4) = 307.124 MW
WC = -ma (h2 h1) = 187.124 MW
Clculo de la eficiencia trmica ( t)
La eficiencia trmica ser:
t
WN
WT WC
120000
Q ENT
ma rr / a H GN k
(477.566)(0.015)(53200)(0.9)
t = 0.349 = 34.9 %
Clculo de flujo de combustible (mc)
Como:
rc / a 0.015
kg.Comb mc
kg . Aire
ma
mc
25788.564
kg
0.0.2149
WN
120000
kW hr
ge = 0.2149 kg/(kW-hr)
23
PRIODO
2006-II
______________________________________________________________________
24
PRIODO
2006-II
______________________________________________________________________
6. ASPECTO ECONMICO:
6.1. COSTO DE INVERSIN:
Segn la GART en el ao 2006 se puede considerar lo siguiente:
25
400
12.7
3
5
25
PRIODO
2006-II
______________________________________________________________________
Para una Central de Gas Natural a ciclo simple de 120 MW.
US $
Cinv 400
KW
6.2.2. DEPRECIACIN:
Sabemos que:
D
d
d 2n
(1 ) 1
2
Donde:
d: Tasa de depreciacin (5%)
n: Aos de vida til (25 aos)
0.05
0.05 2*25
(1
)
1
2
D 2.05 %.
26
PRIODO
2006-II
______________________________________________________________________
6.3. COSTOS FIJOS TOTALES:
C FT
C FT
I D O y M %
US $
* PT KW
KW
PT KW * 8760 H * 0.9
17.75 %
C inv
US $
*120000 KW
KW
120000 KW * 8760 H * 0.9
400
US $
KW
C FT 0.009
Gasto de combustible:
De:
Gc ge * WN(kg/h)
Para:
ge = 0.2149 kg/(kW-hr)
Gc ge * WN(kg/h)
Gc 0.2149 * 120000
Gc 25788 (kg/h)
PRIODO
2006-II
______________________________________________________________________
Gc anual
221384822.4 ( kg)
m3
302603639
.
1
ao
0.7316(kg/m 3 )
Por lo tanto:
US$
MMBTU
CVT
CVT 0.02125
C T 0.009 0.02125
US$
KWh
C T 0.03025
KWh
7. POSIBLE TURBINA:
Se encontr la siguiente turbina en el mercado
28
PRIODO
2006-II
______________________________________________________________________
29
PRIODO
2006-II
______________________________________________________________________
GT11N2 (60Hz)
Fuel
Natural gas
Frequency
60 Hz
Gross Electrical output
120.0 MW
Gross Electrical efficiency
33.6%
Gross Heat rate
10,150 Btu/kWh
Turbine speed
3600 rpm
Compressor pressure ratio
15.5 : 1
Exhaust gas flow
399 kg/s
Exhaust gas temperature
531 C
Nox emissions (corr. to 15% O2,dry)
< 25 vppm
8. CONCLUSIONES ESPECFICAS:
-
El gas natural por ser un combustible ecolgico, por estar en grandes cantidades y
tener un gran poder calorfico reducen los precios significativamente con respecto al
diesel y a otros combustibles fsiles. Slo se va a gastar al ao US$ 20103,403.16 y
se va a recuperar US$ 36568,620.00
30
PRIODO
2006-II
______________________________________________________________________
-
9. CONCLUSIN GENERAL:
Por medio de nuestros conocimientos adquiridos a lo largo de este ciclo en el curso de
Centrales Termoelctrica, se pudo desarrollar satisfactoriamente el diseo y un
presupuesto base de una Central Termoelctrica a Gas de ciclo simple de 120 MW
usando el gas natural como combustible.
31