Está en la página 1de 1

Basic Specifications

EN81-1

Horizontal Dimensions

Vertical Dimensions
EN81-1

1050

P17

17

1275

P18

18

1350

1.0
1.6
1.75
2.0
2.5

Rear
Side
Rear
Side
Side
Rear
Side
Side
Rear
Side

19501930
22101700
20001980
24101740
19102510
24002030
28201740
20202680
24002130
28201840

19701930
22101900
20001980
24101910
19102510
24002030
28201940
20202680
24002130
28201990

14001350

CO

900

16001400
11002100

2S

20001400

CO
2S

1100

12002300

CO

20001500

[Terms of the table]


The contents of this table are applied to standard specifications only. Please consult our local agents for other specifications.
Rated capacity is calculated as 75kg per person, as required by EN81-1.
CO: 2-panel center opening doors, 2S: 2-panel side sliding doors.
Minimum hoistway dimensions (AH and BH) shown in the table are after waterproofing of the pit and do not include plumb tolerance.
Dimensions AH and BH for rated speed 2.5 m/sec in a single hoistway is different from the above table to prevent a wind noise.
Please consult our local agents for details.
This table shows the specifications without the fireproof landing door and counterweight safety.

BB

BB

Entrance
width: JJ

825 <
= Capacity <
= 1350

2.0
2.5

825 <
= Capacity <
= 1050
1050 < Capacity <
= 1350
<
825 = Capacity <
= 1050
1050 < Capacity <
= 1350

TR <
= 90

60
90
90
120 *1
90
120 *1

30
36
30
36

Code number Code number


P17 and P18
1360
1520
1410
1560
1430
1590

90<TR120 P11 and P14


4400
4560
4630

30

Minimum pit depth


(mm)
PD

4720

4820

1550

1650

4950

5050

1900

1900

Minimum
machine room
clear height
(mm)
HM

2250

Minimum
floor to floor
height
(mm)

2500 *2

[Terms of the table]


The contents of this table are applied only to standard specifications without counterweight safety. Please consult our local agents for other specifications.
[Note]
*1 Maximum travel is 90m when the counterweight is installed in a side drop position.
*2 Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm.

JJ

Shown for CO doors


Counterweight rear drop

AA

AA

Shown for CO doors


Counterweight side drop

Shown for 2S doors


Counterweight side drop

AM

Ventilation
grille
Access door
Width=700
Height=2000

Power outlet (by owner)


Power-receiving box (by owner)
Lighting outlet (by owner)

Shown for CO doors


Counterweight rear drop

Shown for CO doors


Counterweight side drop

BM
Lighting outlet
(by owner)
Power-receiving box
(by owner)
Power outlet
(by owner)

Control
Panel

Control
Panel

Lighting outlet (by owner)


Power-receiving box
(by owner)
Power outlet (by owner)

Ventilation
grille

BM

Machine room depth: BM

Control
Panel

AM

Ventilator
(by owner)

Ventilator
(by owner)
Access door
Width=700
Height=2000

Machine room width: AM

Ventilation
grille

1.0
1.6
1.75

Maximum
number of
stops

JJ

Car internal
width: AA

Machine Room
Plan Example

AH

Hoistway depth: BH

Car internal
depth: BB

AH

BH

Hoistway width: AH

Rated capacity
(kg)

Elevation

BH

Hoistway Plan

Maximum
travel
(m)
TR

Rated
speed
(m/sec)

Ceiling height
2200 (standard)

14

Minimum machine
room dimensions
(mm)
AMBM/car

Entrance height: HH
2100 (standard)

P14

Minimum hoistway
dimensions
(mm)
AHBH/car

Ventilator
(by owner)
Access door
Width=700
Height=2000

Shown for 2S doors


Counterweight side drop

Floor to floor height

825

Counterweight
position

Machine room clear height: HM


2250

11

Car internal
dimensions
(mm)
AABB

Entrance
width
(mm)
JJ

Door
type

Overhead: OH

P11

Rated
speed
(m/sec)

Travel: TR

Rated
capacity
(kg)

Pit depth: PD

Number
of
persons

Code
number

EN81-1
Minimum overhead
(mm)
OH

Note: Hoistway section for counterweight side drop is slightly different from this figure.

Applicable Standards
NEXIEZ-MR complies with EN81-1.