Documentos de Académico
Documentos de Profesional
Documentos de Cultura
VERSIONS
APPROVALS
zinc-plated steel
stainless steel
BUILDING MATERIALS
Approved for:
Concrete C20/25 to C50/60,
cracked
Concrete C20/25 to C50/60, noncracked
Also suitable for:
Concrete C12/15
Natural stone with dense structure
ADVANTAGES
APPLICATIONS
FUNCTIONING
http://www.fischer.de/en/ - 02/09/2014
Steel constructions
Guard rails
Brackets
Ladders
Cable trays
Machines
Staircases
Pipeline routes
Ventilation systems
Sprinkler systems
TECHNICAL DATA
ETA-approval
galvanized
Article name
FH II 12/M6 I
FH II 12/M8 I
FH II 15/M10 I
FH II 15/M12 I
Art.-No.
520358
520359
519014
519015
Drill diameter
Anchor length
d0
h1
[mm]
12
12
15
15
[mm]
85
85
95
95
[mm]
77,5
77,5
90
90
Drill diameter
Anchor length
d0
h1
[mm]
12
12
15
15
[mm]
85
85
95
95
[mm]
77,5
77,5
90
90
ETA-approval
A4
Article name
FH II 12/M6 I A4
FH II 12/M8 I A4
FH II 15/M10 I A4
FH II 15/M12 I A4
http://www.fischer.de/en/ - 02/09/2014
Art.-No.
520360
520361
519018
519019
FH II 12/M6 I
FH II 12/M8 I
FH II 15/M10 I
FH II 15/M12 I
gvz
A4
519012
519013
519014
519015
519016
519017
519018
519019
12
85
77,5
12
85 FH 77,5
High performance anchor
II-I
15
95
90
15
95
90
M6
M8
M 10
M 12
11 + U
13 + U
10 + U
12 + U
20 + U
20 + U
20 + U
20 + U
100
50
25
20
LOADS
High performance anchor FH II-I (screw property class 8.85))
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 07/0025 has to be considered.
Type
FH II 12/M6 I
FH II 12/M8 I
FH II 15/M10 I
FH II 15/M12 I
Effective
Min.
anchorage member
depth
thickness
hef
hmin
[mm]
[mm]
60
60
70
70
125
125
150
150
Cracked concrete
Torque Permissible Permissible
Min.
moment tensile load shear load spacing
Tinst
Vperm3)
smin2)
[Nm]
Nperm3)
[kN]
[kN]
[mm]
15,0
15,0
25,0
25,0
4,3
4,3
5,7
5,7
4,6
8,0
13,1
13,7
50
50
60
60
The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an
anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load. The
combination of the given min. spacing and min. edge distance is not possible. One of them has to
be increased according approval.
1)
Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)
[mm]
[kN]
[kN]
[mm]
50
50
60
60
7,6
9,5
14,1
14,1
4,6
8,0
13,1
13,7
60
60
70
70
Min.
edge
distance
cmin2)
[mm]
60
60
70
70
For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
5)
Values for further screw property classes acc. approval.
3)
LOADS
High performance anchor FH II - I A4 (screw property class A4-705))
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 07/0025 has to be considered.
Type
FH II 12/M6 I A4
FH II 12/M8 I A4
FH II 15/M10 I A4
FH II 15/M12 I A4
Effective
Min.
anchorage member
depth
thickness
hef
hmin
[mm]
[mm]
60
60
70
70
125
125
150
150
Cracked concrete
Torque Permissible Permissible
Min.
moment tensile load shear load spacing
Tinst
Vperm3)
smin2)
[Nm]
Nperm3)
[kN]
[kN]
[mm]
15,0
15,0
25,0
25,0
4,3
4,3
5,7
5,7
3,2
6,0
9,2
13,7
50
50
60
60
The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an
anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load. The
combination of the given min. spacing and min. edge distance is not possible. One of them has to
be increased according approval.
1)
http://www.fischer.de/en/ - 02/09/2014
Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)
[mm]
[kN]
[kN]
[mm]
50
50
60
60
5,3
9,5
14,1
14,1
3,2
6,0
9,2
13,7
60
60
70
70
Item
Min.
edge
distance
cmin2)
[mm]
60
60
70
70
For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
5)
Values for further screw property classes acc. approval.