Está en la página 1de 50

System Architecture

Copyright Alvarion Ltd.

Objectives


Upon completion of this module students will know the


following:

Shelf components

Mechanical concept
LED indications
Specifications

Ver. 09-04-01

Access Systems

Product Highlights











Point to Multipoint
connection
Based on WiMAX forums
standards
802.16e ready.
Non Line-of-Sight (NLOS)
coverage
End-to-end Quality of
Service (QoS)
Adaptive Modulation
Technology
High throughput
Long distance
Various types of CPE
Advanced management
application

Ver. 09-04-01

For detailed information about the next


slides please refer to the: BreezeMAX
TDD Modular Base Station System Manual

Base Station Shelf Architecture

100 / 1000 Mbps Ethernet switch


Indoor

Ver. 09-04-01

BMAX-BST-AUODU-ff
(outdoor)

sector
#1

BMAX-BST-AUODU-ff
(outdoor)

sector
#2

BMAX-BST-AUODU-ff
(outdoor)

sector
#3

Ethernet
10/100 Mbps
BMAX-CPEODU-PRO SA-ff

BMAX-CPE-IDU-1D
(indoor)

hub /
switch

ALVR-VG-1DnV-C

PC
PC

ALVR-VG-1DnV-C
BMAX-CPEODU-PROSE-ff

(R)

Router

Backbone

Base Station Antenna


(BS-ANT-dg-p/3.3-3.8)

CPE Antenna
(ANT-g)

BMAX-CPE-IDU-NG-4D1W
(indoor)

BMAX-BST-AUODU-ff
(outdoor)

sector
#4

BMAX-BST-AUODU-ff
(outdoor)

sector
#5

Indoor

BMAX-BST-AUODU-ff
(outdoor)

sector
#6

BMAX-CPE-Si-E/U-ff

PC

PC

802.11g

PC

PC

PC

Hub / Switch / Gateway


Base Station
Station
Base
Shelf
Shelf

BMAX-GPS-IGA
(indoor)

BMAX-GPS-OGR
(indoor)

Wireless

ALVR-VG1DnV-C

(BMAX-BS-SH)
(BMAX-BS-SH)

PC
Indoor

PC

PC

100 / 1000 Mbps Ethernet switch


Indoor

Ver. 09-04-01

(R)

Router

Backbone

Base Station Chassis (Shelf)

Base Station
Shelf
(BMAX-BS-SH)

An 8U + 1U high cPCI (compact Peripheral Component


Interconnect) shelf

Designed for installation in a 19 or ETSI (23) rack

Has a total of nine double Euro (6U high) slots, for AUs and
NPUs, and six single Euro (3U high) slots, for PIUs and PSUs

All the modules are hot swappable, and high availability can be
provided through multiple redundancy schemes

The Base Station chassis contains an air convection and


ventilation fan tray (Air Ventilation Unit)

Air Ventilation Unit (AVU)

2U high

10 brush-less fans,
where 9 fans are
sufficient for cooling a
fully loaded chassis

Failure is indicated by
both the front panel
LEDs and a trap that is
sent to the
management system

The chassis may


operate with the hotswappable fan tray
extracted
for up 10 to minutes

Redundancy 9 + 1

Ver. 09-04-01

AVU

Air Ventilation Unit (AVU)

AVU
No

Label

Function

Module handle

PWR LED

Green - AVU power is OK


Red - 12 VDC power failure

ALRM LED

When lit (and PWR LED is Green) - one or more of the fans
failed
When lit (and PWR LED is Red) - 12 VDC power failure

Mounting screws

Ver. 09-04-01

Network Processing Unit (NPU)

NPUs








Ver. 09-04-01

(NPU) serves as the heart of


the base station
Connectivity via a 100/1000
BaseT
Management port
10/100 BaseT
Traffic classification and
connection establishment
Data switching & forwarding
Service Level Agreements
management
Base station overall
management
Serial port for monitor
connection

Network Processing Unit (NPU)

The NPU should be


inserted to slot number
5
 NPU Redundancy
(future release) 1 +1
 Master / slave schema
one card active ,one
updating.


NPUs

Ver. 09-04-01

10

Network Processing Unit (NPU)

11

NPUs

No

Label

Function

23

Card handle

22

PWR LED

Green - NPU power is OK


Red - NPU power failure

21

Ver. 09-04-01

MASTER
LED

When lit - the NPU is the primary


(master) NPU

GPS/SYNC
LED

Off - GPS/IF clock synchronization


is disabled
Green - GPS/IF clock is
synchronization enabled

DATA
connector

RJ-45 used to connect the NPU to


the backbone

MGMT
connector

RJ-45 used to connect the NPU to


the Out-Of-Band management
network

GPS/SYNC
IN
connector

ALARM IN
connector

For future use

Card handle

10

Card handle lock

Connection to a GPS Adapter

20
19

2
3
4
5

18
17

16
15

14

13
12
11
10

Network Processing Unit (NPU)

12

NPUs

No

Label

Function

23

When lit - the hot swap circuit is


active and the card can be safely
removed

22

11

HOT SWAP
LED

3 pin low profile connector used for


accessing and debugging the NPU
via the monitoring program

13

RESET
button

Used to perform hardware reset to


the AU-IDU

17

14

ALARM
OUT
connector

For future use

15

15

GPS/SYNC
OUT
connector

For future use


14

MGMT port activity LED when


blinking - Ethernet activity at the
management port

MGMT port integrity LED when lit Ethernet physical layer is OK

12
11

DATA port activity LED when


blinking - Ethernet activity at the
data port

18

Ver. 09-04-01

20

MON
connector

17

21

12

16

19

4
5

18
6

16
7

13

10

Network Processing Unit (NPU)

13

No

NPUs

19

Label

Function

MGMT port integrity LED when


lit - Ethernet physical layer is
OK

EXT
ALRM
LED

For future use

BST
ALRM
LED

When lit - failure in one (or


more) BS modules

22

ALRM
LED

When lit - NPU failure

23

Card handle lock

20

21

23
22

2
3

21
20
19

4
5

18
17

16
15

14

13
12
11
10
Ver. 09-04-01

Access Unit (AU)

AUs

Ver. 09-04-01

14

IF Tx 240 MHz and Rx 140 MHz

Contains the MAC and modem

Responsible for wireless network


connection establishment

Bandwidth management

Four 3.5/5 MHz PHY channels

Connects to the AU-ODUs via


Intermediate Frequency (IF) cables

Carrying full duplex data, control and


management signals

Power (-48 VDC)

64 MHz synchronization reference


clock

14 MHz channel for management

Supports up to 510 SUs

AUs

Access Unit (AU)

Two types of AU-IDU




Four Channels-HP:
standard AU-IDU for BreezeMAX TDD systems.
supports high currents up to 3.5 A of -54 VDC
power supply from the PIU

Four Channels-HP-4M:
AU card for the 4Motion mobile WiMAX solution,
hardware-ready for migration to the mobile
WiMAX compatible

Ver. 09-04-01

15

Access Unit (AU)

AUs

Ver. 09-04-01

AUs

16

AU-IDU Redundancy
(future release)

Redundancy scheme 6 +1

Access Unit (AU)

17

AUs

No

Label

Function

Card handle

10

PWR LED

Green - AU-IDU power supply is OK


Red - AU-IDU power supply failed
Off - AU-IDU is not powered

WACT LED

Off No IDU Transmission


Green IDU Transmission OK

7
7

IP LED

Off - No downlink IP activity


Green (blinking) - Downlink IP
activity

AUs
3

Ver. 09-04-01

PWR LED
(ODU1- 4)

Green - ODU power is OK


Red - ODU power failure

ODU (1- 4)
connector

TNC connector for the IF cable


connection to the ODU1 - 4

Alarm LED
(ODU1- 4)

When lit - IDU to ODU


communication failure

SP

WLINK LED

10

ALARM

2
3
4
5
6
5
6
5
6

7
5
6
12

For Future Use


When lit - at least one SU is
connected
Off - AU-IDU is OK
Red - AU-IDU Failure

11

Base Station Shelf Components

18

No

Label

Function
When lit - the hot swap circuit
is active and the card can be
safely removed

10

11

HOT
SWAP
LED

12

RESET
button

Used to perform hardware


reset to the AU-IDU

AUs

AUs

7
7

3
4
5
6
5
6

7
5
6
7
5
6
12
11

1
Ver. 09-04-01

Power Interface Unit (PIU)

Filters and stabilizes the base station input


power

Protects from power problems such as


over voltage, surge pulses, reverse polarity
connection and short circuits

Chassis contains two slots


for an optional 1+1 PIU redundancy

Regular PIU support:

Up to 8 ODU

High power PIU

Ver. 09-04-01

35A current

58A current
Up to 20 ODU

Regular PIU

DC power source (48 VDC)

High power PIU

PIUs

19

Power Interface Unit (PIU)



PIU
AU-IDU-4C

In order to use the power cord


with the high power PIU
The wires should be shortcut as
illustrated
High Power

AU-IDU-4C

AU-IDU-4C

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

AU-IDU-4C

AU-IDU-4C

AU-IDU-4C

Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

20

GND
-48V
RTN

Regular

Power Interface Unit (PIU)

21

7
No

Label

Function

PWR LED

Green - PIU power is OK


Red - PIU power input is out of
range or PIU card is damaged

HOT
SWAP
LED

When lit - the hot swap circuit is


active and the card can be safely
removed

Card handle lock

Card handle

-48 VDC connector

6
1

5
2

PIUs

MASTER
LED

When lit - the PIU is the master


PIU

Mounting screw

Ver. 09-04-01

Power Interface Unit (PIU)

PIUs

Ver. 09-04-01

PIU Redundancy 1+ 1

22

Power Supply Unit (PSU)

PSUs

Ver. 09-04-01

PSUs

23

A 48 VDC power supply unit

Each Base Station chassis


can contain up to four PSU
modules providing N+1
redundancy configurations

The following table provides


the installation requirements
for the PSU
Number of AU-IDUs

Minimum Required
Number of PSUs

1-2

3-6

Power Supply Unit (PSU)

24

PSUs

PSUs

No

Label

Function

Mounting screw

Card handle

Card handle lock

ALARM
LED

When lit - power input is out of


range or PSU is damaged or PSU
is inhabited by NPU

PWR LED

When lit - PIU power is OK

5
4
2
3

Ver. 09-04-01

Base Station Shelf Components


PSUs

AUs

NPUs

25

AUs

PIU
AU-IDU-4C
PIU
AU-IDU-4C
PSU
AU-IDU-4C

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

PIU
s

PSU
s

AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

AVU

Base Station Redundancy Summary

26

PIU
AU-IDU-4C
PIU
AU-IDU-4C
PSU
AU-IDU-4C

The following redundancy schemes are


supported by the base station chassis:

Network Processing Unit (NPU)


1+1
Redundancy is currently not supported

Power Supply Unit (PSU)

N+1

Power Interface Unit (PIU)

1+1

Air Ventilation Unit (AVU)

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

AU-IDU-4C
PSU
AU-IDU-4C
PSU

Access Unit (AU)


6+1
Redundancy is currently not supported

AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

1 (built-in)

Global Positioning System

PIU

The GPS is required to avoid any


inter-site (between BSs) interferences

In a TDD system

AU-IDU-4C
PIU
AU-IDU-4C
PSU

The F/B ratio of the SUs is preventing the


other base station from interfering

There is only one frequency for receive and


transmit. If the base stations are not
synchronized, when BS#1 transmit and BS#2
receives, the transmission of BS#1 interferes
with the transmission of SU2

AU-IDU-4C

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C

The synchronization between the base


stations is done using GPS and same
UL/DL ratio within the network

PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

BMAX-GPS-IGA
(indoor)

BMAX-GPS-OGR
(outdoor)

27

Global Positioning System

Connect
ed
Base
Station

Ver. 09-04-01

28

1 PPS
- 30 dB
due to
F/B

1 PPS

Global Positioning System

PIU

AU-IDU-4C
PIU
AU-IDU-4C
PSU
AU-IDU-4C

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

The GPS clock required is 1 PPS


(Pulse Per Second) with an
accuracy of 10e-11 and maximum
jitter of 100ns
The GPS system transmits two
streams of information:
PPS - Pulse Per Second
a stream of pulses separated by
1 second
PPS ID a number identifying
the PPS, in terms of
microsecond elapsed from
January 1 2000, until the
respective PPS pulse

BMAX-GPS-IGA
(indoor)

BMAX-GPS-OGR
(Outdoor)

29

Global Positioning System

PIU

AU-IDU-4C
PIU

AU-IDU-4C

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

PSU

Indoor

Ver. 09-04-01

AU-IDU-4C

NPU

NPU

AU-IDU-4C
PSU
AU-IDU-4C

PSU
AU-IDU-4C
PSU

Calculations are executed every


PPS
Shifts between the GPS clock and
Base Station clock are compensated
by using an on-going algorithm
Indoor or outdoor installed GPS unit
Synchronized to at least 4 satellites
There is one type of GPS, Outdoor
GPS receiver - AQUTIME-2000
(Trimble)
GPS Adapter connects the GPS unit
to the NPU
Chaining is supported on release 4.2
only for microBS

AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

BMAX-GPS-IGA
(indoor)

BMAX-GPS-OGR
(Outdoor)

30

Global Positioning System

PIU

12 VDC power source,


supplied by the NPU via the
GPS Adapter

The RS-422 interface allows


installation at distances up
to 100meters/328 feet
Hold-Over capabilities in
case of poor (less than 2)
satellite detection (default
Hold-Over time 30min)
After Hold-Over time (user
defined) AUs operation can
continue normally or stop TX
operation (user defined)

AU-IDU-4C
PIU
AU-IDU-4C
PSU
AU-IDU-4C

100 / 1000 Mbps Ethernet switch


Indoor

Ver. 09-04-01

NPU

(R)

Router

Backbone

NPU

AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C

PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

BMAX-GPS-IGA
(indoor)

BMAX-GPS-OGR
(Outdoor)

31

GPS Adapter Unit

PIU

AU-IDU-4C
PIU
AU-IDU-4C

PSU
AU-IDU-4C

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C

32

The GPS Adapter is


powered by 12 VDC
supplied by the NPU
The GPS Adapter is
installed in a 1U high
panel (the same
panel that is used for the
ODU Power Feeders)
The GPS select switches
state should be:
ODU ON; IDU and INT
OFF

PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

BMAX-GPS-IGA
(indoor)

BMAX-GPS-OGR
(Outdoor)

GPS Adapter Unit

33

PIU
AU-IDU-4C
PIU
AU-IDU-4C
PSU

AU-IDU-4C

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

7
No

Label

PWR

Off - Power input failure


Green - 12 VDC power supply from NPU is OK

1PPS

Blinking Green - 1PPS signal from GPS Receiver is


detected
Red - 1PPS signal is not detected

Active GPS ODU

Green - indicates that the selected GPS Receiver is


ODU (Outdoor)
Off - ODU GPS Receiver is not selected

AU-IDU-4C
PSU

AU-IDU-4C
PSU
AU-IDU-4C

PSU
AU-IDU-4C
Base Station
Shelf
(BMAX-BS-SH)

BMAX-GPS-IGA
(indoor)

BMAX-GPS-OGR
(Outdoor)

Function

GPS Adapter Unit

34

PIU
AU-IDU-4C
PIU
AU-IDU-4C
PSU

AU-IDU-4C

100 / 1000 Mbps Ethernet switch


Indoor

Ver. 09-04-01

No

Label

Function

Active GPS - IDU

Green - indicates that the selected GPS Receiver is


IDU (Indoor)
Off - IDU GPS Receiver is not selected

Active GPS - INT

For future use

INT CLOCK

For future use

BMAX Interface

GPS Select

NPU

(R)

Router

Backbone

NPU

AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

BMAX-GPS-IGA
(indoor)

BMAX-GPS-OGR
(Outdoor)

J1 Connector Connects the adapter box to NPUs


GPS connector
3 On/Off switches to manually select the
connected GPS type (up on, down off)

GPS Adapter Unit

35

PIU
AU-IDU-4C
PIU
AU-IDU-4C

PSU
AU-IDU-4C

No

Label

Function

NPU

Internal- GPS-ANT

For future use

AU-IDU-4C

IDU GPS

Used to connect indoor installed GPS


unit, control channel and 1PPS signal

ODU GPS

Used to connect all outdoor installed


GPS unit via RS-422 interface

Ground Screw

Ground cable connection to the unit

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

PSU
AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

BMAX-GPS-IGA
(indoor)

BMAX-GPS-OGR
(Outdoor)

Access Unit Outdoor Unit High Power


PIU
AU-IDU-4C
PIU
AU-IDU-4C

BMAX-BST-AUODU-HP-TDD-F.X-B
(outdoor)

Half Duplex multi-carrier radio


unit

Connects to an external
antenna

High transmit power and low


noise figure

Supports bandwidth up to
10Mhz

Output power (at antenna


port):

PSU
AU-IDU-4C

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU
NPU

Indoor

AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C

PSU
AU-IDU-4C

Base Station
Station
Base
Shelf
Shelf

(BMAX-BS-SH)
(BMAX-BS-SH)

Ver. 09-04-01

sector
#1

New - 3.3a GHz 32 1 dBm


(range of 24 - 32 dBm)
New - 3.3b GHz 33 1 dBm
(range of 24 - 33 dBm)
2.xGHz - 36 1 dBm (range of
30 - 36 dBm)
3.4 - 3.6GHz - 34 1 dBm (range
of 24 - 34 dBm)

36

Access Unit Outdoor Unit High Power

37

PIU
AU-IDU-4C
PIU
AU-IDU-4C

Frequency Range

Resolution

2.3 (WCS)

2305 - 2315, 2350 236O

125Khz

2.3 (WCS) Extended

2305 2317, 2348 - 2360

125Khz

2.3

2300-2360 MHz

125Khz

NPU

2.5A

2496-2602 MHz

125Khz

AU-IDU-4C

2.5B

2590-2690 MHz

125Khz

3.3A

3300-3355 MHz

125Khz

3.3B

3345-3400 MHz

125Khz

3.4A

3399.5-3455 MHz

125Khz

3.4B

3445-3500 MHz

125Khz

3.5A

3500-3555 MHz

125Khz

3.5B

3545-3600 MHz

125Khz

3.6B

3650-3700MHz

125Khz

AU-IDU-4C

100 / 1000 Mbps Ethernet switch

(R)

Router

NPU
Backbone

sector
#1

Band

PSU

Indoor

BMAX-BST-AUODU-HP-TDD-F.X-B
(outdoor)

PSU
AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

Access Unit Outdoor Unit High Power

38

1
2

PIU
BMAX-BST-AUODU-HP-TDD-F.X-B
(outdoor)

AU-IDU-4C
PIU

sector
#1

6
3

AU-IDU-4C

PSU
AU-IDU-4C

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
PSU

No

Label

Function

ETH LED

When lit - at least one SU is associated

PWR LED

When lit - AU-ODU power is OK

ALARM LED

When lit - AU-ODU failure

IF Connector

TNC connector for the IF cable connection to the


AU-IDU

AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

N-Type connector to connect the antenna

Access Unit Outdoor Unit High Power

39

8
PIU
BMAX-BST-AUODU-HP-TDD-F.X-B
(outdoor)

AU-IDU-4C
PIU

sector
#1

1
2

7
6

AU-IDU-4C

PSU
AU-IDU-4C

100 / 1000 Mbps Ethernet switch


Indoor

Ver. 09-04-01

NPU

(R)

Router

Backbone

NPU

AU-IDU-4C
PSU
AU-IDU-4C

No

Label

Function

BAND Sticker

A sticker indicating the band of the AU-ODU


(either A or B)

Impermeability test screw, for internal use only.


Opening of this screw may impair the sealing of the
unit against moisture and humidity

PSU
AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

Grounding screw

Power Feeder

40

PIU
BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)

AU-IDU-4C
PIU

BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)

PSU
AU-IDU-4C

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

AU-IDU-4C

BMAX-BST-PWR
PWR-FEED

AU-IDU-4C

sector
#1

BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)
sector
#1

The ODU Power Feeder is used


to provide power (-48 VDC) to
the AU-ODU-HP

It transfers transparently all


signals between the AU-IDU and
the ODU, while injecting
DCpower received from an
external source

Each ODU Power Feeder unit


can serve up to four High Power
ODUs

Up to three ODU Power Feeder


units can be installed in a 1U
high Power Feeder panel

BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)

PSU
AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

Power Feeder

41

PIU
BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)

AU-IDU-4C
PIU

BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)

PSU
AU-IDU-4C

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

AU-IDU-4C

BMAX-BST-PWR
PWR-FEED

AU-IDU-4C

sector
#1

6
5

BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)
sector
#1
BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)

PSU
AU-IDU-4C
PSU

No

Label

Function

IDU 1 - 4

Connection to ODU connectors of AU-IDUs/Micro Base


Station

ODU PWR 1 - 4
LED

When lit (Green) - AU-ODU-HP is connected and powered


When lit (Red) - Power output problem (short or overload)

AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

3
4

Grounding screw
-

-48 VDC connector

Power Feeder

42

PIU
BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)

AU-IDU-4C
PIU

BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)

PSU
AU-IDU-4C

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

AU-IDU-4C

BMAX-BST-PWR
PWR-FEED

AU-IDU-4C

sector
#1

6
5

BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)
sector
#1
BMAX-BST-AU-ODUHP-TDD-F.X-B
(outdoor)

PSU
AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

No

Label

Function

ODU 1 - 4

Connections to IF connectors of AU-ODU-HP


units

PWR

When lit - ODU Power feeder power is OK

Access Unit Antenna

43

PIU
AU-IDU-4C
PIU
AU-IDU-4C

BMAX-BST-AUODU-ff
(outdoor)

Sectorial antenna (Dual Slant)

PSU
AU-IDU-4C

sector
#1

Azimuth Beam-Width 90
Elevation Beam-Width 8 2

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

Gain 15.5 dBi

Frequency 2.3 - 2.7 GHz

N-Type Connector

50 impedance

Polarization of each antenna is 45deg from the vertical center:


Port 1: +45deg from the center
Port 2: -45deg from the center

Polarization between the antenna is crossed (90deg) which


provides isolation of more than 25dB

IF Cable

44

PIU
AU-IDU-4C
PIU
AU-IDU-4C

BMAX-BST-AUODU-ff
(outdoor)

Connects the AU-ODU to


the AU-IDU/Micro Base
Station

Carrying both signals


and power

The maximum permitted attenuation of the IF


cable at applicable frequencies depend on its
screening effectiveness and its maximum
permitted DC resistance
(further information are provided in the Base
Station User Manual)

Recommended to use
double shielded cables

PSU
AU-IDU-4C

NPU

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

Indoor

Ver. 09-04-01

AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

sector
#1

Cables recommended by
Alvarion and their
maximum length

Cable

AU-ODU-HP

LMR-195

30m

LMR-240

60m

LMR-400

150m

IF Cable

45

PIU
BMAX-BST-AUODU-ff
(outdoor)

AU-IDU-4C
PIU
AU-IDU-4C
PSU
AU-IDU-4C

NPU

Indoor

Ver. 09-04-01

100 / 1000 Mbps Ethernet switch

(R)

Router

Backbone

NPU

AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
PSU
AU-IDU-4C
Base Station
Station
Base
Shelf
Shelf
(BMAX-BS-SH)
(BMAX-BS-SH)

sector
#1

The IF cable carries


Full duplex data
Control and management signals
Power (-48 VDC)
64 MHz synchronization reference clock
from the IDU to the ODU
IF Frequencies
Tx: 240 MHz
Rx: 140 MHz
IDU-ODU service channel at 14 MHz serves
for bi-directional control, status and
management signaling

Single Channel per AU, No Diversity

46

This is the basic configuration

Each AU-IDU connects to one


ODU

Serving a single sector with a


directional antenna

ver. 07-06-10

Alvarion Training Services

ll Rights Reserved Alvarion 2007

Served
Sector

Multiple Channels per AU, No Diversity

Up to 4 channels per AUIDU can be used to cover


several sectors one ODU
per sector

47

ODU-1
Sector 1
ODU-2
Sector 2
ODU-3
Sector 3

4 sectors of 90each with


frequency reuse 1 or

ODU-4
Sector 4

AU-IDU share a common


MAC and modem

ODU-1
Sector 1
ODU-2
Sector 2

ODU-4
Sector 4

ver. 07-06-10

Alvarion Training Services

ll Rights Reserved Alvarion 2007

ODU-3
Sector 3

2nd Order Diversity




One sector

Space diversity

Two AU-ODU

Channels 1,2

ODU-1
Sector 1

Same frequency and


transmit power

ODU-2
Sector 1

Same AU-IDU share a


common MAC and
modem

ver. 07-06-10

Alvarion Training Services

ll Rights Reserved Alvarion 2007

48

4th Order Diversity




Single sector

Single AU-IDU with 4


ODUs

Space and polarization


diversities

Using dual polarization


slant antennas
Channels 1 and 2 form
one pair

Channels 3 and 4 form


one pair

Same frequency and


transmit power are set
for all four ODUs

Common MAC and


modem
Ver. 09-04-01


49

ODU-1
Sector 1
ODU-2
Sector 1
ODU-3
Sector 2
ODU-4
Sector 2

Thank You

Copyright Alvarion Ltd.