Está en la página 1de 20

User Manual

Entrance control system 61-200-3103

CONTENTS
Description ............................................................................................................................................. 3

1.1

Entrance Control System 61-200-3103 ............................................................................. 4

1.2

Specifications ........................................................................................................................ 5

1.3

Packing List ........................................................................................................................... 5

Setup & Operations .............................................................................................................................. 6

2.1

Mounting................................................................................................................................. 7

2.2

Operation ............................................................................................................................. 11

2.3

Settings................................................................................................................................. 14

2.4

Range Settings.................................................................................................................... 16

Description
1.1 Entrance Control System 61-200-3103
1.2 Specifications
1.3 Packing list

1.1 Entrance Control System 61-200-3103


Eurostat entrance control systems help to ensure that operators cannot enter the EPA unless
their wrist straps and footwear are compliant on a daily basis. It complies with ANSI/ESD
S20/20 specification.
The Turnstiles provide wrist strap and/or footwear measurement. By touching a sensor, both
ESD shoes are tested separately through measuring electrodes which are installed in the
contact mat.
The wrist strap resistance value can be checked by connecting it to the front of the turnstile
(wrist strap checking must first be set)
In order to ensure its safe and stable running, please pay attention to the indications given in
this manual.

Entrance:
After confirming the equipment conformity, the tripod is unlocked.
The operator can enter by pushing the upper arm to rotate the tripod.
Exit:
Tripod is unlocked via button.

Features:

In the case of an interruption in power, the horizontal arm folds down

Resistance value displayed on LEDs

Arms are locked when they are not turned after a passage authorization

Pictograms display the respective walking directions while entering or leaving the EPA

1.2 Specifications
Power Voltage

240 VAC 10 %, 50 Hz

Test voltage
Test range

20 VDC 5%
Min : 100 k ; Max : 35 M

Clear passage width


Test time
Mounting
Housing
Weight
Dimensions

ca. 510 mm
3 seconds
4 x M12 lag bolt
Stainless steel
Turnstile : 30 Kg ; Packed : 55 Kg
Turnstile : 16,5 x 13 x 38,5 (W x D x H) ; Packed : 15,75 x 18,5 x 41,75

Warranty

1 year

Certifications

1.3 Packing List


Before proceeding to installation, please check the components according to the following
parts list:

Turnstile 61-200-3103
Power cord
Footplate for 61-200-3103
Black cable-gland
Tripod system
3 Tripod fixation screws
One set of two (2) keys
This manual

Setup & Operations


2.1 Mounting
2.2 Operation
2.3 Settings

2.1 Mounting
1. First, choose an installation position according to the site and ensure that the turnstile
correctly prevents access to the EPA. For a better adaptation to different configurations,
the turnstile is equipped with grommet on the right side, the left side and the rear.
2. Open the front panel with the keys provided.

3. With a permanent marker, draw the position of the mounting holes on the floor.

4. Move the turnstile and drill the holes with a hammer drill.
5. Place the dowels into the holes, reposition the turnstile and tighten the four lag bolts so
that the turnstile is completely stable.

If the pre-drilled mounting holes do not correspond to the site configurations, it is possible to
drill new holes using a metal cutting drill.

6. Pass the power cord inside the cable-gland and fix it to the turnstile.

7. Connect the power supply to the connection terminal.

! For safety reasons, this operation has to be done by an authorized person !


If the supply cord is damaged, it must be replaced by a special cord available from
EUROSTAT Group or its service agent.
8. Pass the footplates cables inside the turnstile through the rubber piece and connect
them to the tester plugs.

! Ensure the correct plug colour is connected to the corresponding right/left shoe
electrode!

9. Fix the footplate to the floor with two M6 bolts or by gluing.

10. Place the tripod system on the turnstile and fix it with the 3 bolts (use a size 6 Allen key)

11. Check if wires/bolts are correctly fixed and if nothing is obstructing the rotation of the
arms.
12. Switch the turnstile power on and close the front panel.

13. To lock the middle arm, push it down to its maximum and then lift it until hearing the
sound of the magnet.

14. Turnstile is now ready to use.

For safety reasons, emergency stop can be installed on the supply cord of the turnstile.
In case of Power interruption, the middle arm will fall.

2.2 Operation
To ensure the proper operation of the equipment, please:
-

Do not force the rotation of the arm when the passage is locked.
The turnstile should be used in an internal area protected from humidity.

1. Before testing, the top screen displays the following label, which indicates that the
passage is locked.

2. Place the feet on the corresponding electrodes of the footplate.

3. Attach the wrist strap to the connections on the front side of the turnstile.

Female banana
plug

4mm Snap

Male banana
plug

10 mm Stud

4. The measurement starts by touching the sensitive electrode on the top of the turnstile. A
bip sound and two green LEDs indicate the beginning of the test

! This position has to be maintained until the end of the test !


5. When the measurement is finished, three LEDs display show the resistance value of
each piece of equipment.

6. If the test is compliant, the top screen displays a green arrow which indicates that the
passage is unlocked and which shows the entry direction.

7. Push the middle arm with body to rotate the tripod and enter the EPA.

8. If the test is not compliant, the top screen doesnt change and nothing happens.
9. To quit the EPA, no test is needed. Push the button on the side of the turnstile, the top
screen displays a green arrow which indicates the exit direction.

2.3 Settings
The 61-200-3103 turnstile is equipped with shoes & wrist strap tester. To suit all types of
needs, it is possible to choose the equipment to be tested: shoes only / wrist-strap only /
shoes & wrist-strap.
1. Open the top cover with the keys provided.

2. The tester mainboard is located on the right hand side, on the left of this electronic board
there is a setting button.

3. Simultaneously press the setting and test buttons.

4. Choose the equipment to be tested by pressing the test button.

Wrist-strap only

Shoes only

Shoes & Wrist-strap


5. Confirm choice by pressing the setting button.
6. To finish the setting procedure, press the buttons in the following order :
- Test
- Setting
- Test
A green arrow is displayed for few seconds on the top screen.
The turnstile is now ready to use.

2.4 Range Settings


It is possible to change the values of the test limits. To do this you must first get a calibration
plug corresponding to the desired values from Eurostat.
Range of Low limits available: 0 - 2 M
Range of High limits available: 2 - 200 M
1. Open the top cover with the keys provided.

2. The tester mainboard is located on the right hand side. A RS232 plug is connected under
this board. Unplug it and proceed to the following instructions :

3. Proceed in the same manner as in Chapter 2.3 and stop at point 4. Once the equipment
to be tested is selected, simultaneously press the setting and test buttons.

4. The red LEDs are illuminated.

5. Simultaneously press the setting and test buttons.


6. The red and green LEDs are illuminated.

7. Press the setting button only.

8. The Wrist strap Low limit's red LED is illuminated:

9. Insert the calibration plug in the RS232 connection previously cleared.

10. Press the setting button only.


11. The green LED flashes once time and the Wrist strap High limit's red LED is illuminated.

12. Press the setting button only.

13. The green LED flashes once time and the Footplate Low limit's red LEDs are illuminated.

14. Press the setting button only.


15. The green LED flashes once time and the Footplate High limit's red LEDs are illuminated.

16. Press the setting button only.


17. The green LED lights up.

18. Simultaneously press the setting and test buttons.


A green arrow is displayed for a few seconds on the top screen.
The turnstile is now ready to use.

También podría gustarte