Está en la página 1de 59

THE NATIONAL

BUILDING CODE
(CONDO)
DE GUZMAN, SUSHMITA SEN C.
GUERRIN, GLADYS ANNE
MEJIA, ELAND JETHRO
PUZON, DANE STEFI MARIE P.
SANTOS, KITT
TEMPLO, CHARMAINE Y.

CLASSIFICATION AND GENERAL


REQUIREMENTS OF ALL BUILDINGS
BY USE OR OCCUPANCY
USE OR OCCUPANCY

A. Dwellings
B. Hotels
Apartments
Dormitories

UNIT AREA PER OCCUPANT


(Sq. m.)

Minimum of Two Exits other


than elevators are required
where number of occupant is
over

28
18.6
18.6
18.6

10
10
10
10

National Building Code of the Philippines

OCCUPANCY TYPE

Section 701
GROUP A
RESIDENTIAL
DWELLINGS

GROUP B
RESIDENTIAL
, HOTEL, AND
APARTMENTS

Section 702
No change shall be made in the character of occupancy of any
building.
Section 703
One-storey building with more than one occupancy each portion
shall conform to the requirement of each.

National Building Code of the Philippines

TYPES OF OCCUPANCY
SEPARATION
1.) One Hour Fire Resistive
Operation
2.) Two Hour Fire resistive
Operation
3.) Three Hour Fire Resistive
Operation
4.) Four Hour Fire Resistive
Operation

http://continuingeducation.construction.com/article.php

LOCATION ON PROPERTY
No buildings shall be constructed unless it adjoins a street

National Building Code of the Philippines

LOCATION ON PROPERTY

National Building Code of the Philippines

LOCATION ON PROPERTY

National Building Code of the Philippines

LOCATION ON PROPERTY

National Building Code of the Philippines

MAXIMUM HEIGHT OF
BUILDINGS

National Building Code of the Philippines

MAXIMUM HEIGHT OF
BUILDINGS

National Building Code of the Philippines

MEASUREMENT AND
PERCENTAGE OF SITE
OCCUPANCY

National Building Code of the Philippines

MEASUREMENT AND
PERCENTAGE OF SITE
OCCUPANCY

National Building Code of the Philippines

MEASUREMENT AND
PERCENTAGE OF SITE
OCCUPANCY

National Building Code of the Philippines

SETBACK REQUIREMENT

Type of Residential Use / Occupancy


R-1
R-2
(meters)
Basic
Maximum
(meters)
(meters)

R-3
Basic
(meters)

Front
Side

4.50
2.00

3.00
2.00**

8.00*
2.00**

3.00
***

Rear

2.00

2.00

2.00

***

YARD

Maximum
(meters)

R-4
(individual
lot / unit
meters)

R-5
(meters)

8.00*
2.00
(optional)
2.00

4.50
2.00
(optional)
2.00

6.00
3.00
3.00

National Building Code of the Philippines

PARKING REQUIREMENT

3.60m * 12.00m bus/tracks


National Building Code of the Philippines

PARKING REQUIREMENT

National Building Code of the Philippines

PARKING REQUIREMENT

1.20 M
3.70 M
National Building Code of the Philippines

ELEVATOR
10.1 ACCESSIBLE ELEVATOR
SHOULD BE LOCATED NOT MORE
THAN 30.00 M FROM THE
ENTRANCEAND SHOULD BE
EASY TO LOCATE WITH THE AID
OF SIGNS

10.2 ACCESSIBLE ELEVATORS


SHALL HAVE A MINIMUM
DIMENSION OF 1.10 M. x 1.4 M.

National Building Code of the Philippines

CEILING HEIGHTS

Min. 2.10 m

Min. 2.40 m

Min. 2.40 m

Min. 2.70m

National Building Code of the Philippines

CEILING HEIGHTS
1st Floor w/ Natural
Ventilation
Min. 2.70 m

MEZZANINE FLOORS
Min. 1.80 m.

Stairways 1
National Building Code of the Philippines

SIZE AND DIMENSIONS


OF ROOMS

0.90 m

Min. Area = 1.20 sq. m

National Building Code of the Philippines

PWD BATHROOM

30 M

National Building Code of the Philippines

KITCHEN

National Building Code of the Philippines

WINDOW OPENING

10 % FLOOR AREA

National Building Code of the Philippines

ARCADE

MIN. 3.00 M

ARCADE

National Building Code of the Philippines

BUILDING PROJECTION
OVER PUBLIC STREETS

National Building Code of the Philippines

CORRIDORS
3.4 A MINIMUM CLEAR LEVEL
SPACE OF 1.50 M X 1.50 M
SHALL BE PROVIDED BEFORE
EXTENDING BEYOND A DOOR;
EXCEPTION: WHERE A DOOR
SHALL OPEN ONTO BUT NOT
INTO A CORRIDOR, THE
REQUIRED CLEAR, LEVEL
SPACE ON THE CORRIDOR
SIDE OF THE DOOR MAY BE A
MINIMUM OF 1.20M
CORRIDOR WIDTH
3.5) PROTECTION SHOULD BE
PROVIDED FROM DOORS THAT
SWING INTO CORRIDORS

National Building Code of the Philippines

RAMPS

1:12 RATIO
National Building Code of the Philippines

STAIRWAYS

National Building Code of the Philippines

STAIR LANDING
max.
3.60 m

Min. 2.00
m

Max. 1.20 m

National Building Code of the Philippines

HAND RAIL

3m

3m

0.80 m < x > 0.90 m

National Building Code of the Philippines

EXITS
Total Width of Exits > total occupant load served / 165
OCCUPANT LOAD

NO. OF EXITS

Above first storey


More than 10

500-999

1000 or more

Occupant load of more


than 10

EXIT 1

EXIT 2

National Building Code of the Philippines

Exit 1

Exit 2

500 999 Occupant Load

EXIT DISTANCES
EXIT

< 1/5
EXIT

National Building Code of the Philippi

EXIT

National Building Code of the Philippi

10.7 lux

MIN OF 1.10 M

National Building Code of the Philippi

MIN OF 2 M

Hazardous Areas/ 50 or
more load

DOOR EXIT

National Building Code of the Philippi

NATIONAL BUILDING CODE


OF THE PHILIPPINES
(Mall)
DE GUZMAN, SUSHMITA SEN C.
GUERRIN, GLADYS ANNE
MEJIA, ELAND JETHRO
PUZON, DANE STEFI MARIE P.
SANTOS, KEITH L.
TEMPLO, CHARMAINE Y.

Building Occupancy
Group E:
Business & Mercantile

National Building Code of the Philippines

National Building Code of the Philippines

PARKING REQUIREMENTS
Building Type

Number of parking slot

Markets

1 slot/150 sq.m. of shopping floor


area

Restaurants, Fast-food centers,


bars and beerhouses

1 slot/30 sq.m. of customer area

Office buildings

1 slot/125 sq.m. of gross floor area

Other buildings in business/


commercial zones

1 slot/125 sq.m. of gross floor area

Public assembly buildings


(theaters, cinemas, auditorium,
stadium, etc.)

1 slot/50 sq.m. of spectators area

Building Type (Recreational


Facilities)

Number of parking slot

Bowling Alleys

1 slot/4 alleys

Amusement center

1 slot/50 sq.m. of gross floor area

National Building Code of the Philippines

PERPENDICULAR PARKING

5.00m

2.40m

PARALLEL PARKING

2.00m
6.00m

National Building Code of the Philippines

12.00m

5.00m
3.60m

2.40m

Truck and Bus

Diagonal Parking

National Building Code of the Philippines

PARKING FOR PWD

1 accessible parking slot for the handicapped per 50 parking lots up to 150
slots and an additional slot for every 100 slots
Maximum distance of accessible parking area from facility served. Parking
areas for the physically handicapped shall be within 60.00m of the facility
being served.
FACILITY SERVED
WALKWAY

PARKING
SLOT

PARKING
SLOT

PARKING
SLOT

PARKING
SLOT

PARKING
SLOT

National Building Code of the Philippines

ONE WAY 3.00m


TWO WAY
7.20m

13.50m

5.70m
2.55m to 2.70m

90 DEG. PARKING BAY


ONE SIDE

Planning and Designers Handbook (Second Edition)


Max B. Fajardo Jr.

ONE WAY
3.00m

19.00m to 19.50m

TWO WAY
7.20m

5.70m
2.55m to 2.70m

90 DEG. PARKING
BAY TWO SIDES

Planning and Designers Handbook (Second Edition)


Max B. Fajardo Jr.

90

18.60

5.70

7.20

18.60

5.70

7.20

60

18.00

6.30

5.40

16.65

5.65

5.40

45

15.80

5.80

3.90

13.85

4.97

3.90 Planning and Designers Handbook (Second Edition)

Max B. Fajardo Jr.

R = 17.00m
to 21.00m

UP

4.00m to
4.50m

DN

4.00m to
4.50m

Planning and Designers Handbook (Second Edition)


Max B. Fajardo Jr.

Bus

17.60m

2.10m

2.70m

7.60m

3.00m

Planning and Designers Handbook (Second Edition)


Max B. Fajardo Jr.

Section 1207. Stairs, Exits, and Occupant Loads


C 1: Exit Door shall swing in the direction of travel.
Double Acting Doors shall not be used as exits.

NATIONAL BUILDING CODE OF THE PHILIPINES

Section 1207. Stairs, Exits, and Occupant


Loads
C-3: Exit doorway shall be of a size as to permit the
installation of a door not less than 900mm and not less
than 2.00m in height

NATIONAL BUILDING CODE OF THE PHILIPINES

Section 1207. Stairs, Exits, and Occupant


Loads
C-5: Revolving, sliding, and overhead doors shall
not be used as required exits.

NATIONAL BUILDING CODE OF THE PHILIPINES

Section 1207. Stairs, Exits, and Occupant


Loads
D-1: Every corridor or exit balcony shall not be
less than 1.10 meters in width

NATIONAL BUILDING CODE OF THE PHILIPINES

Section 1207. Stairs, Exits, and Occupant


Loads

D-3: When more than one exit is required, they shall


be arranged to allow going to either direction from
any point in the corridor.

NATIONAL BUILDING CODE OF THE PHILIPINES

Section 1207. Stairs, Exits, and Occupant


Loads
Corridors and exterior exit balconies with dead ends
are permitted when the dead end does not exceed
6.00 meters in length

NATIONAL BUILDING CODE OF THE PHILI

Section 1207. Stairs, Exits, and Occupant


Loads
E-1: Stairway widths
Occupant Load (X) = Minimum Width
X > 50
= 1100MM
X < 50
= 900MM
X < 10
= 750MM

Trim and handrails shall not reduce the required width by


more than 100MM

NATIONAL BUILDING CODE OF THE PHILI

Section 1207. Stairs, Exits, and Occupant


Loads

E-3: Winding stairways may be used if the required


width of the run is provided at a point not more than
300MM from the side where the treads are
narrower.

NATIONAL BUILDING CODE OF THE PHILI

Section 1207. Stairs, Exits, and Occupant


Loads
E-5: Every landing shall be a dimension measured in the
direction of travel equal to the width of the stairway.
Such dimension need not exceed 1.20m when the stairs
has a straight run.

NATIONAL BUILDING CODE OF THE PHILI

Section 1207. Stairs, Exits, and Occupant


Loads
K: Exits shall be illuminated at any time the
building is occupied.

NATIONAL BUILDING CODE OF THE PHILI