Customer wanted to know the procedure to recover the 6400 from corrupted
flash and the procedure to recover the switch from corrupted images
Note: Once you enter the below command youll need to match this speed in
your terminal emulator
=>setenv baudrate 115200
Step # 3 Set boot flags to force switch to stop boot process at Miniboot
=>setenv bootflags 0x1000
Save boot and check environment
=>saveenv
=>printenv ensure bootflags = 0x1000
Step 4 # Load Miniboot You should see the Miniboot prompt after this
step. [Miniboot]->
=>run miniboot
Step 5 # Format Flash
[Miniboot]->diskInit /flash
Alcatel-Lucent Enterprise
Document rev. 1.0
1/5
[Miniboot]-> setNextRunningVersion 2
Step 9 # Reboot switch interrupt boot process by hitting any key at the
begging of the boot process
[Miniboot]-> Reboot
Alcatel-Lucent Enterprise
Document rev. 1.0
2/5
Note: Once you enter command youll need to match this speed in your
terminal emulator
=>setenv baudrate 9600
=>setenv bootflags 0x0
=>saveenv
Step 11# Continue boot process
=>Boot
Step 12 # Login to switch
login: admin
Password:switch
Note: Once you enter the below command youll need to match this
speed in your terminal emulator
=>setenv baudrate 115200
Step # 3 Set bootflags to force switch to stop boot process at Miniboot
=>setenv bootflags 0x1000
Alcatel-Lucent Enterprise
Document rev. 1.0
3/5
[Miniboot]-> setNextRunningVersion 2
Step 7 # Reboot switch interrupt boot process by hitting any key at the
begging of the boot process
[Miniboot]-> Reboot
Step 8 #Change baudrate and flag to default
=>setenv baudrate 9600 - Once you enter command youll need to match
this speed in your terminal emulator
=>setenv bootflags 0x0
=>saveenv
Alcatel-Lucent Enterprise
Document rev. 1.0
4/5
Alcatel-Lucent Enterprise
Document rev. 1.0
5/5