CAMA-III mini Vandal-Proof Mini Speed Dome Camera User’s Manual Ver. 1.1
INFORMATIONS
CE Marking
Our products are manufactured to comply with requirements of following directives and national regulations
implementing the directives:
This appliance is marked according to the European 1000VAC Directive on Waste Electrical and Electronic
Equipment (2002/96/EC) and further amendments. By ensuring this product is disposed of correctly, you will
help to prevent potential negative consequences for the environment and human health, which could otherwise be
caused by inappropriate waste handling of this product.
The symbol on the product, or the documents accompanying the product, indicates that this appliance may not be
treated as household waste. It shall be handed over to the applicable collection point for the waste electrical and electronic
equipment for recycling purpose. For more information about recycling of this product, please contact your local authorities,
your household waste disposal service or the shop where you purchased the product.
Concerning for human health protection and friendly environment, we assure that our products falling under
RoHS Directive regulations, regarding the restriction of the use of hazardous substances in electrical and
electronic equipment, were designed and manufactured in compliance with mentioned regulation.
Simultaneously, we claim that our products were tested and do not contain hazardous substances exceeding
limits which could have negative impact on human health or natural environment.
Information
The device, as a part of professional CCTV system used for surveillance and control, is not designed for self installation in
households by individuals without technical knowledge.
The manufacturer is not responsible for defects and damages resulted from improper or inconsistent with user’s manual
installation of the device in the system.
SAFETY REQUIREMENTS
WARNING!
KNOWLEDGE OF THIS MANUAL IS THE NECESSARY CONDITION
GUARANTEEING PROPER FUNCTIONING OF THE DEVICE. WE SUGGEST
STUDYING THE MANUAL PRIOR TO INSTALLATION AND FURTHER DEVICE
USAGE.
WARNING!
USER IS NOT ALLOWED TO DISASSEMBLE THE CASING IF THERE ARE NO USER
-SERVICEABLE PARTS INSIDE THIS UNIT. ONLY AUTHORIZED SERVICE PERSONNEL
MAY OPEN THE UNIT
INSTALLATION AND SERVICING SHOULD ONLY BE DONE BY QUALIFIED SERVICE
PERSONNEL AND CONFORM TO ALL LOCAL REGULATIONS
WARNING!
PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT DESCRIBED FOR THE GIVEN
PRODUCT IN USER’S MANUAL AND OTHER DOCUMENTS DELIVERED WITH THE
PRODUCT, OR IF IT DOES NOT ARISE FROM THE USUAL APPLICATION OF THE
PRODUCT, MANUFACTURER MUST BE CONTACTED UNDER THE RIGOR OF
EXCLUDING THE MANUFACTURER’S RESPONSIBILITY FOR THE RESULTS OF SUCH AN
ACTION.
TERMS OF SAFETY
1. We are kindly requesting for keeping this manual for camera lifespan when referring to contents of
manual would be necessary;
2. Safety precautions included in this manual should be strictly followed, because they have a direct
influence on user’s safety and also on durability and reliability of the device;
3. All actions conducted by the servicemen and users must be accomplished in accordance with the
user’s manual;
4. During maintenance device should be disconnected from power sources;
5. Usage of additional devices and components neither provided nor recommended by the producer is
forbidden;
6. Mounting the device in places where proper ventilation cannot be provided (e. g. closed lockers
etc.) is not recommended since it may lead to heat build-up and damaging the device itself as
a consequence;
7. Mounting the camera on unstable surface or using not recommended mounts is forbidden.
Improperly mounted camera may cause a fatal accident or it may be seriously damaged itself.
Camera must be mounted by qualified personnel with proper authorization, in accordance with
user’s manual;
All rights reserved © AAT Holding Sp. z o.o.
3
CAMA-III mini Vandal-Proof Mini Speed Dome Camera User’s Manual Ver. 1.1
TERMS OF SAFETY
8. Device should be supplied only from power sources which parameters are in accordance with
those pointed out by the producer in camera technical datasheet. Therefore, it is forbidden to
supply the camera from power sources with their parameters unknown, unstable or not meeting the
producer’s requirements;
10. Signal cables (conducting TV or / and telemetric signal) should be placed in a way excluding the
possibility of damaging them by accident. Special attention must be paid to cables getting from the
camera and connecting the power supply;
11. To avoid equipment damage, whole TV circuit should be equipped with properly made (in
accordance with Polish Regulations) discharge-, overload- and lightning protection devices. Usage
of separating transformers is advised;
12. Electric installation supplying the device should be designed to meet the specifications given by
the producer in such a way that overloading is impossible;
13. Camera should be protected from water and objects that may get inside it;
14. User cannot repair or upgrade equipment himself. All maintenance actions and repairs should be
made only by the qualified service personnel;
15. Unplug the camera from the power source immediately and contact the proper maintenance
department when the following occurs:
♦ Damages to the power cord or to the plug itself;
♦ Liquids getting inside the device or exposure to strong mechanical shock;
♦ Device behaves in a way not described in the manual and all adjustments approved by the
manufacturer and possible to apply by user himself, seem not to have any effect;
♦ Camera is damaged;
♦ Atypical behaviour of the camera components may be seen (heard).
16. In necessity of repairs attention to using only original replacement parts (with their parameters in
accordance with those specified by the producer) should be paid. Non-licensed service and non-
genuine replacement parts may cause fire or electrocution;
17. After maintenance activities tests should be run to ensure proper work of all the functional
components of the device.
Attention!
Manufacturer reserves the possibility of printing mistakes appearing and technical data chan-
ging without notice.
TABLE OF CONTENTS
1. TABLE OF CONTENTS
Information .................................................................................................2
Safety requirements ....................................................................................3
Terms of safety ............................................................................................3
1. Table of contents .....................................................................................5
2. General characteristics ............................................................................6
3. Technical data .........................................................................................7
4. Package contents .....................................................................................9
5. CAMA-III mini junctions and connection types ...................................10
5.1. CAMA-III mini controls ..............................................................11
6. CAMA-III mini microswitch settings ...................................................12
6.1. Addressing the camera (ID) .........................................................13
6.2. Control protocol settings ..............................................................23
6.3. TV standard settings .....................................................................23
6.4. Transmission speed settings .........................................................24
6.5. Termination settings .....................................................................24
7. Camera controlling - NOVUS-C1, N-CONTROL protocol ..............25
8. Camera controlling - PELCO-D / PELCO-P protocol .........................27
9. Camera OSD menu................................................................................30
9.1. Auto scans ...................................................................................31
9.2. Presets...........................................................................................33
9.3. Tours.............................................................................................38
9.4. Patterns .........................................................................................41
9.5. Alarms ..........................................................................................43
9.6. Area titles .....................................................................................44
9.7. Privacy zones................................................................................45
9.8. Camera setup ................................................................................46
9.9. Dome setup ...................................................................................51
9.10. Function run ...............................................................................58
10. Mounting the NVC MSD-322DN camera ..........................................59
10.1. Mounting on flat surfaces (ceiling) without bracket ..................60
10.2. Mounting on ceilings and walls with bracket.............................62
10.2. Mounting on dropped ceilings tiles ............................................65
11. Mounting the NVC MSD-322DN/O camera ......................................68
11.1. Mounting on walls with NVB-SD40WB bracket ......................69
11.2. Mounting on ceiling with NVB-SD40CB bracket ....................72
11.2. Mounting on walls with NVB-SD40PWB_230 bracket ............75
Appendix 1 - CAMA-III mini menu language setting procedure .............82
Appendix 2 - Short cut keys .....................................................................83
GENERAL CHARACTERISTICS
2. GENERAL CHARACTERISTICS
TECHNICAL DATA
3. TECHNICAL DATA
Model NVC-MSD322DN NVC-MSD322DN/O
Motion detection (in preset) Sensitivity, Position, Delay, Output, Hold time,
Area Title 8
Privacy Zone 4
TECHNICAL DATA
NVC-MSD322DN NVC-MSD322DN/O
“Auto-Flip” function,
Home function
Flickerless function,
Sharpness adjustment
Resolution adjustment
Image flip
Preset freeze
Weather & vandal proof, die-cast aluminium camera enclosure
IP 66
12 VDC/24 VAC 24 VAC
12 W 45 W
1.5 kg 2.2 kg
TECHNICAL DATA
4. PACKAGE CONTENTS
If any of the listed equipment has been damaged during transport or if package is incomplete, the con-
tents of package should be packed back to the original box. Contact the local NOVUS distributor for
further assistance.
Video output
Video output
Red
AC+ AC- DC+/AC+
Power supply
12VDC / 24VAC
White DC-/AC-
Green
+(TX)-
Black
G AI G AO
Alarm input
Grey NO / NC
Yellow
Alarm output
Black & white
Pink
+(H&F)-
Power supply
NVC-MSD322DN/O
for heater and fan
Model
Brown 24VAC
Pin Function
AI Alarm input
WARNING!
While the camera is AC-supplied and polarization of the power supply is not important, AC+ and AC -
pins are distinguished. Connecting one phase to one type of proper pin while using multiple devices is
advised. Heater and additional fan only in NVC-MSD322DN/O model.
Control devices such as keyboards, DVRs, PCs communicate with camera via RS-485 standard. UTP
cat. 5 cable is advised as transmission medium. One pair of wires is used in the data transmission,
maximum distance of communication (for RS-485 and 0,35 mm² wire should not exceed 1200 meters).
For RS-485 connections please use camera pins described as R+ and R-, which should be connected
with TX+ i TX– pins in the controlling device (keyboard NV-KBD70 for example). When multiple
cameras with cascade connection are available, you should use the same R+ and R- connections.
Green R+
TX+
+(TX)-
RS-485 Control
Blue R - TX -
When using star-like connection type, use the proper command signal splitter e.g. NVRS-016DD.
SW 1 SW 2 SW 3
To avoid hardware control conflicts, each camera should have an unique address in the system. For
setting the camera address switches 1-8 located in SW1 switch section should be used.
When setting up the system with a single DVR, please associate the camera addresses so they match
the DVR video input numbers (depending on which input the video signal is connected to).
ATTENTION!
Each camera has an address of 1 !
Camera adress
SW 1 Settings
(ID number)
1 2 3 4 5 6 7 8
1 ON OFF OFF OFF OFF OFF OFF OFF
2 OFF ON OFF OFF OFF OFF OFF OFF
3 ON ON OFF OFF OFF OFF OFF OFF
4 OFF OFF ON OFF OFF OFF OFF OFF
5 ON OFF ON OFF OFF OFF OFF OFF
6 OFF ON ON OFF OFF OFF OFF OFF
7 ON ON ON OFF OFF OFF OFF OFF
8 OFF OFF OFF ON OFF OFF OFF OFF
9 ON OFF OFF ON OFF OFF OFF OFF
10 OFF ON OFF ON OFF OFF OFF OFF
11 ON ON OFF ON OFF OFF OFF OFF
12 OFF OFF ON ON OFF OFF OFF OFF
13 ON OFF ON ON OFF OFF OFF OFF
14 OFF ON ON ON OFF OFF OFF OFF
15 ON ON ON ON OFF OFF OFF OFF
16 OFF OFF OFF OFF ON OFF OFF OFF
17 ON OFF OFF OFF ON OFF OFF OFF
18 OFF ON OFF OFF ON OFF OFF OFF
19 ON ON OFF OFF ON OFF OFF OFF
20 OFF OFF ON OFF ON OFF OFF OFF
21 ON OFF ON OFF ON OFF OFF OFF
22 OFF ON ON OFF ON OFF OFF OFF
23 ON ON ON OFF ON OFF OFF OFF
Exemplary configuration
Using switches no. 2 ~ 4 in camera SW 2 switch section please select control protocol matching
the one set in the keyboard. When using other controllers (PC for example), please contact your soft-
ware manufacturer. NOVUS-C1 protocol works with 9600 bps by default, PELCO-D works with
2400 bps.
2 3 4
N-Control, Novus C, OFF OFF OFF
Novus C1, Pelco-D, Pelco-P
(auto detection)
Service Settings Other Settings
The switches no. 1 section SW2, are used for video type setup. Set to ON position for PAL signal, or
to OFF position for NTSC signal.
TV SW 2 Settings SW 2
Standard
type
1
PAL ON
NTSC OFF
Transmission speed set in the camera and controlling device (keyboard, DVR, PC computer) should
be the same. Moreover, speed should be matching the one designed for particular control protocol
(NOVUS-C1 works with 9600 bps, PELCO-D 2400 bps).
Transmission SW 2 Switch
Speed [BPS] Settings
SW 2
5 6
2400 OFF OFF
4800 OFF ON
9600 ON OFF
19200 ON ON
The camera which is connected at end of the line, must have the cable of communication terminated
by setting the below switch to ON. Without termination option enabled camera controls may
malfunction or controlling might be impossible at all.
Total length of the cable communication should not exceed 1200 m.
Termination SW 3 Switch SW 3
status Settings
Termination ON ON
Termination OFF OFF
To establish proper connection between camera and keyboard following conditions must be met:
− an unique camera address for the whole system
− the same baud rate (speed setting) in the camera and in the keyboard (2400/4800/9600)
Details regarding camera control settings are described in proper manual of the keyboard. To start
controlling the camera please enter the camera number from the numpad and apply it by pressing
F1 key called (for NV-KBD40) or with key (NV-KBD70 keyboard).
When using NV-KBD70 keyboard, camera control buttons are located in the bottom part of the
keyboard, the numpad, and joystick.
When working with NV-KBD40 keyboard, function keys, numpad, and joystick are used.
Action Function
Go into sub-menu.
Execute command.
Joystick left or right
Change value.
Navigate through menu items.
Joystick up or down Navigate through menu items.
Joystick down Finish editing title.
Change value.
ZOOM handle twist
Enter editing title mode.
b) Functions of particular keys of NV-KBD40 and NVKBD70 keyboards are described in the table
Marking in NV-KDB70 NV-KBD40
Function
User’s manual Keyboard Keyboard
+
PRESET SET PRESET SET
Save the preset
In order to establish proper connection between camera and keyboard following conditions must be
met:
− unique camera address for the whole system
− the same baud rate (speed setting) in the camera and in the keyboard (2400/4800/9600)
Action Function
Go into sub-menu.
Execute command.
Joystick left or right
Change value.
Details of setting the camera controls are described in keyboard user’s manual. To start controlling
the camera please enter the camera number from the numpad and apply it by pressing key called
F1 (for NV-KBD40) or with key (NV-KBD70 keyboard).
WARNING!
For confirming the selected option in the camera menu or for answering “Yes” you have to call preset
no. 95 using the numerical keys 9 and 5 and the button PRESET MOVE. For cancelling the option
and answering ”No” you have to call preset no. 96 using keyboard keys 9 and 6 and PRESET
MOVE.
c) Functions of particular keys of NV-KBD40 and NVKBD70 keyboards are described in the table
below:
+
PRESET SET PRESET SET Saves preset
SCAN SCAN
Auto-scan function
PATTERN PATERN
Pattern function
ESC ESC
Exit from the menu
Before programming or operating the CAMA-III mini camera, you have to select a desired camera
number using numerical keys and press CAM (confirmation key).
Accessing the CAMA-III mini menu depends on the controller type and the protocol used.
All the details regarding the camera communication parameters are described in the instruction
manuals of the NV-KBD40 and NV-KBD70 keyboards.
WARNING!
The procedure of camera programming refers to the keys of the NV-KBD40 and the
NV-KBD70 keyboards and the telemetry protocol NOVUS-C1.
When using a different controller or protocol select control buttons appropriate for given function.
Menu is accessible after pressing MENU button, ESC key closing the menu. When additional
functions (such as tour or auto-scan) or when camera is in alarm mode, menu is accessible only after
abandoning current mode (e.g. by forcing the tilt or pan movement or by confirming alarm).
a) MAIN MENU
DOME MENU
AUTO SCAN
PRESET
TOUR
PATTERN
ALARM
AREA TITLE
PRIVACY ZONE
CAMERA
DOME SETUP
FUNCTION RUN
EXIT(ESC TO EXIT)
Auto scan function allows for programming the camera to move horizontally (pan) with defined zoom
factor between defined „START” and „END” points.
NVC-MSD322DN series cameras support up to 4 programmed auto scans, and one auto pan mode
under 9 number. Each auto-scan may be called by using 10 alphanumeric chars.
To access AUTO SCAN menu, select the appropriate tab from the menu by using joystick.
NUMBER : 01
TITLE : A01
MODE : NORMAL
SPEED : 5 STEP
START ANGLE : 239.2 024.4 ---
END ANGLE : 287.3 026.4 ---
SCAN DIR : CCW
SWAP : OFF
DWELL : 03 SEC
SAVE AND EXIT (ESC TO CANCEL)
8. In SCAN DIR position set the camera movement direction - CW - camera will pan clockwise,
CCW- pan counter clockwise
9. In SWAP position user can swap the closing angle and the initial angle of auto scan
10. In DWELL position set the waiting time on the START and END ANGLE points (from 1 up to
99 seconds);
11. Select the SAVE AND EXIT option to exit and save changes or ESC to exit without saving
changes.
To bring up pre-programmed auto-scan function, after exiting camera menu, select the appropriate
auto-scan number from 1 to 4 and confirm it by pressing SCAN button, to call back auto pan function
select the 9 numerical key and press SCAN button.
WARNING! In case of black-out, camera will continue its last auto-scan after restoring power.
d) Pressing HOME while particular auto-scan number is highlighted, erases this auto-scan.
High-speed dome NVC-MSD322DN cameras have the possibility to pre-program 120 scenes (presets).
Pre-programmed presets may be brought up directly from keyboard, used in tour function, or used as
default camera action in parking and alarm functions.
To access PRESET menu, please use joystick and select PRESET tab from the main menu.
PRESET SETUP
NUMBER : 001
TITLE : AUTO
CAMERA SET
DWELL : 03 SEC
12345678901234567890
00 *-------------------
02 --------------------
04 --------------------
06 --------------------
NEXT PAGE
SAVE AND EXIT(ESC TO CANCEL)
Presets menu consist of three pages enabling to program 60 presets each. To go on to next page select
the NEXT PAGE position using the joystick.
Each preset can be given a name consisting of max. 12 alphanumerical characters given by the
administrator. The operator can also program the focus control mode, exposure control , motion
detection and park time period in patrol function from 3 up to 99 seconds.
To erase the selected preset, move the cursor to the desired preset position (marked *) and press the
HOME button.
Select the SAVE AND EXIT option to exit from menu and save changes or ESC to exit without
saving changes.
MOTION SETUP
SENSITIVITY : AUTO
POSITION : ALL
DELAY : 00 SEC
OUTPUT : OFF
HOLD TIME: 03 SEC
SAVE AND EXIT(ESC TO CANCEL)
e) Programming presets
- directly - move the camera to the desired position, select the preset number using numerical keys
and press the PRESET SET button.
- from the camera menu - following the programming procedure :
1. Press the PRESET SET button for entering the preset menu,
2. Use the joystick for selecting the preset number, title and dwell time in the patrol function,
3. Move the cursor to the desired preset position and press the PROGRAM or IRIS OPEN
button to enter the programming mode,
4. Use the joystick to move camera to desired position,
5. Press PROGRAM or IRIS CLOSE button for exiting from the programming mode,
After execution of this action preset is already programmed. Additionally there is a possibility to
program focus control, automatics exposition and motion detection for each preset.
AE SETUP menu structure and way of programming has been described in chapter 9.8.
i) Calling presets
There is a possibility to call the same preset in CAMA-II mini, CAMA-III mini and CAMA-II,
CAMA-III cameras in the CCTV system.
To call preset globally use numeric keys for selecting the preset number (from 1 up to 120) and press
the GLOBAL button.
All the cameras with the selected global mode and the NOVUS-C/NOVUS-C1 or N-control protocol
will move to the selected preset (the preset has to be programmed before this operation).
9.3. TOURS
WARNING !
Second level tours cannot call for additional tours (third-level tours) - in this case they are simply
ignored according to the scheme below:
If:
Tour1 consist of: Preset1→Preset2→Tour2→Tour 3
Tour2 consist of: Preset3→Preset4→Tour4→Preset5
Tour3 consist of: Preset6→Pattern1
Tour4 consist of: Preset7
TOUR SETUP
NUMBER : 01
TITLE : T01
SCAN TYPE : NORMAL
SPEED : 5 STEP
DWELL : 6 SEC
003 A08 P01 T02 --- --- ---
--- --- --- --- --- --- ---
--- --- --- --- --- --- ---
--- --- --- --- --- --- ---
--- --- --- --- --- --- ---
--- --- --- --- --- --- ---
SAVE AND EXIT(ESC TO CANCEL)
Each tour function can be given a name consisting of max. 12 alphanumerical characters given by the
administrator (the manner of introduction and the characters have been described in chapter 10.9
point h2) , camera movement mode and park time period (3-99 seconds) can be also defined.
b) Programming tours
4. Use the joystick for moving the cursor to next positions and select the function
according to the description in point 3,
5. Select the SAVE AND EXIT option to exit and save changes or ESC to exit without saving
changes.
WARNING !
Only the previously programmed (saved) functions (preset positions, auto scans, patterns, tours) are
accessible for selection from the camera menu and can be used for tour programming.
c) Calling tours
WARNING !
To assure the camera movement (pan only) between successive presets with a programmed speed, you
have to insert an auto scan between the selected presets with the start angle position identical with the
preceding preset and the end angle position identical with the following preset (e.g. 003 A08 016). In
other way camera will move from position 003 to 016 in shortest possible way.
9.4. PATTERNS
NVC-MSD322DN series cameras supports up to 4 patterns. Each pattern consist of stored camera
operations (pan / tilt, rotation, zoom, etc.), that can be activated directly from the keyboard or used in
the home / tour functions. The maximum total time for patterns is 200 seconds and can be shared by
all 4 patterns.
PATTERN SETUP
Each pattern function can be given a name consisting of max. 12 alphanumerical characters given by
the administrator.
b) Programming patterns
To erase the selected pattern, move the cursor to the desired preset position and press the HOME
button.
c) Calling patterns
1. After closing the camera menu, select the pattern number using numerical keys and press
PATTERN.
2. Use the RUN FUNCTION menu (description in chapter 9.10).
WARNING !
If total pattern time exceeds 200 seconds, the camera automatically exits program mode.
9.5. ALARMS
The NVC-MSD322DN series camera supports up to 1 alarm inputs and 1 alarm outputs (both NO and
NC type). When an alarm signal occurs on the alarm input, the camera activates the function
programmed for this input. As an alarm function you can use any previously programmed preset,
pattern, auto scan or tour.
ALARM SETUP
NVC MSD-322DN series camera supports up to 8 area titles defined by start and end angles.
The area titles are displayed on the monitor when camera moves between the programmed angles.
NUMBER: 1
TITLE: ==========
START ANGLE: 000.0
END ANGLE: 000.0
SWAP: OFF
SAVE AND EXIT(ESC TO CANCEL)
Each area can be given a name consisting of max. 12 alphanumerical characters given by the
administrator .
If there are any areas that require special privacy in the CAMA-III mini camera monitoring range, the
picture zone masking function may be used. NVC MSD-322DN series cameras support up to 4
programmable dynamic privacy zones.
Each privacy zone can be given a name consisting of max. 12 alphanumerical characters assigned by
the administrator.
CAMERA SETUP
FOCUS CONTROL
WB CONTROL
AE CONTROL
DNR CONTROL
LINE LOCK CONTROL
SHARPNESS : 7
RESOLUTION : MID
DIGITAL ZOOM : OFF
IMAGE FLIP : OFF
PRESET FREEZE : OFF
SAVE AND EXIT(ESC TO CANCEL)
FOCUS SETUP
MODE : AUTO
AF SENSITIVITY : NORMAL
FOCUS LIMIT : NORMAL
SAVE AND EXIT(ESC TO CANCEL)
WB SETUP
MODE : AUTO
R GAIN : 210
B GAIN : 210
EXIT(ESC TO EXIT)
AE SETUP
MODE : AE1
SLOW SHUTTER : OFF
GAIN :
BRIGHT : 003
SHUTTER :
FLICKERLES : OFF
BACKLIGHT : OFF
WDR : OFF
WDR LEVEL :
NIGHT SHOT : AUTO
SAVE AND EXIT(ESC TO CANCEL)
AE1: automatic exposure mode, the shutter is fixed to 1/50 sec. for PAL camera, an d t h e l i gh t
focused on the CCD module is limited by changing the iris, gain and brightness levels. For
SHUTTER set to AUTO mode, the AES is optimized for light condition. AUTO mode is set
by default and it is recommended for outdoor light conditions;
SHUTTER PRIO: the shutter level is adjusted manually. Gain and iris levels automatically
change depending on the light conditions (slow shutter function is disabled in this mode);
MANUAL: iris, gain and shutter levels are adjusted manually (slow shutter function
is disabled in this mode);
SLOW SHUTTER: enable (ON), disable (OFF) the slow shutter function;
GAIN: manual adjustment of the gain level: MIN, LOW, MID, HIGH;
BRIGHT: adjustment of the brightness level, the range from 0 to 15;
SHUTTER: manual adjustment of the shutter speed in the range from 1/50 to 1/100 000;
FLICKERLESS: this function can be enabled (ON) or disabled (OFF),
BACKLIGHT: back light compensation function can be enabled (ON) or disabled (OFF), This
function is used for exposing the objects in front of bright backgrounds;
WDR: wide dynamic range function, used for scenes with strong differences in light conditions. This
mode can not be used with backlight compensation (BLC) function simultaneously;
WDR LEVEL: manual adjustment of the WDR level;
NIGHT SHOT: day / night mode of the CAMA-III mini series cameras (colour or B/W picture) can
be switched automatically, manually or globally. When switching to B/W mode the infra red cut-off
filter is removed for more effective camera operation in low light conditions:
AUTO: in auto mode day and night modes switch according to the current ambient
illumination level;
ON: camera works in continuous b/w mode;
OFF: camera works in continuous colour mode;
GLOBAL: d/n modes of all cameras may be changed by one command given via keyboard;
To turn on night mode, enter 888 from the numpad and confirm it by pressing
GLOBAL key.
To turn on daylight mode (colour), enter 999 from the numpad and confirm it by
pressing GLOBAL key.
ATTENTION !
Global mode is available only with NOVUS-C, NOVUS-C1 or N-Control protocols.
DNR SETUP
2DNR(1) : 001
3DNR(1) : 010
2DNR(2) : 001
3DNR(2) : 003
SAVE AND EXIT(ESC TO CANCEL)
DNR digital noise reduction, reduce the nois when you capture picture in low light environment.
Digital nois reduction level is separate adjustable for;
2DNR(1) - static picture when no camera moving, from OFF/01 up to 07;
3DNR(1) - movement picture when no camera moving, from OFF /01 up to 31;
2DNR(2) - static picture when camera moving, from OFF/01 up to 07;
3DNR(2) - movement picture when camera moving OFF/01 up to 31;
MODE : INTERNAL
PHASE : 000
SAVE AND EXIT(ESC TO CANCEL)
MODE: CAMA-II series cameras can be synchronized with the internal generator:
(INTERNAL) or from the power supply frequency (EXTERNAL);
PHASE: phase adjustment from 0° up to 309° with 1° step;
f) SHARPNESS: Adjustment of the sharpness level from 0 up to 15, where 15 is for the sharpest
picture.
h) DIGITAL ZOOM:
OFF - digital zoom function is disabled (full zoom range is limited to the optical zoom
only);
2X - digital zoom value is limited 2x;
4X - digital zoom value is limited to 4x;
MAX - 16x maximum digital zoom range;
Please note that when high value of digital zoom is used, the picture quality is getting worse, and the
compression block of pixels becomes visible. This effect is related to the digitalization process and it
is normal for digital zoom.
i) IMAGE FLIP: function can be enabled (ON) or disabled (OFF). When it is enabled it turns the
video output from the camera upside down and reverse it horizontally.
j) PRESET FREEZE: : function can be enabled (ON) or disabled (OFF). When the function is
enabled the image is frozen during the preset.
CONFIGURATION MENU
LANGUAGE :ENGLISH
HOME FUNCTION SETUP
OSD DISPLAY
VIEW ANGLE SETUP
INITIALIZE DATA
ORIGIN OFFSET
DOME RESET
SYSTEM MENU
SYSTEM INFORMATION
SAVE AND EXIT(ESC TO CANCEL)
a) LANGUAGE: select the menu language (English, French, German, Italian, Polish, Portuguese and
Spanish). When the menu is displayed in other then English language use the APPENDIX 1 page 66.
After the programmed time period of keyboard operator inactivity has passed the camera
automatically goes to the programmed function (move to preset position, tour, auto scan, or pattern).
Time period for function activation can be set in the range from 10 up to 240 seconds.
HOME FUNCTION: select the function for keyboard inactivity (NONE, PRESET, TOUR,
PATTERN, AUTOSCAN);
FUNCTION NUMBER: selected function number;
WAITING TIME: select time period for function activation;
FUNCTION ENABLE: enable (ON) / disable (OFF) home function;
CAMERA TITLE: camera can be described by max. 6 alphanumerical characters given by the
administrator;
VIEW DIRECTION: ON option sets current direction as N (north) and the coordinate angle to 000˚.
OFF option hides the directional titles: W, E, N, S;
DOME OSD DISPLAY: enables screen display: camera number and title;
AREA TITLE: this option enables displaying of area titles when the camera moves;
PRESET TITLE: set the preset title display time in the preset mode:
CONSTANT: display the preset title during preset dwell time;
03 - 180 SEC: : set the preset title display time from 03 to 180 SEC;
OFF: disable the preset title display;
FOCUS EXPOSURE: function can be enabled (ON) or disabled (OFF). When it is enabled the
information about focus and exposure function is displayed on the screen;
OSD POSITION SETUP: the menu allows for matching the position of OSD information;
PANNING RANGE
FLIP : ON
TILT OVER ANGLE : W/O BUBBLE
SAVE AND EXIT (ESC TO CANCEL)
d2) FLIP: automatic flip function - the camera turns 180 degrees automatically to allow
monitoring objects directly under the camera. After reaching 90-degree tilt position,
the camera automatically flips, so the image is not displayed upside down.
AUTO: When camera reaches 180°, it will auto-flip to allow further object tracking. Releasing and
moving the joystick in a desired direction is required for this action;
90˚ - 120˚: manual adjustment of the angle flip camera, range from 90˚ - 120˚ ;
OFF: function disable;
d3) TILT LIMIT: enabling this functions limits the camera vertical rotation range, so the camera will
not be „looking through” non-transparent parts of its casing
OFF: function disable;
ON: when this option is set, the camera tilts up over the horizon (about +10 degrees);
INITIALIZE DATA
FACTORY DEFAULT
ERASE PROGRAMMED DATA
PRESET FOCUS DEFAULT
EXIT(ESC TO EXIT)
FACTORY DEFAULT: select this data for bringing back the default (pre-programmed) camera
settings. The default settings are stored in internal flash memory and you can get back these
settings during the camera operation;
ERASE PROGRAMMED DATA: select this option for erasing all auto scan, preset, tour, pattern,
alarm, area title, privacy zone, camera and dome data. You will be asked to enter ON (erase
position) or OFF (do not erase position). Only origin offset settings are not erased. The offset
value can be zeroed only with default set of offset origin menu. When you desire to erase data
then select ERASE, or if you want to exit without erasing press ESC or select SAVE AND EXIT
(ESC TO CANCEL) position;
PRESET FOCUS DEFAULT: the menu set the default mode of the focus when you save the preset.
Enable to select AUTO / MANUAL / ONE PUSH (automatic focus control after every move of
the joystick);
OFFSET SETUP
This function enables scaling of pan and tilt values by setting the offsets. This feature is useful to align
a new camera coordinate settings exactly the same as the previously installed camera.
DOME RESET
CANCEL
OK
This feature is used to reset the camera by menu command to initialize and auto calibrate the camera
exactly like after turning off the power supply.
To restart select OK , to cancel the operation select CANCEL or press ESC button.
OFFSET SETUP
MOTOR SETUP
PASSWORD EDIT
ORGIN CHECK
PROGRAM UPGRADE
PASSWORD ENABLE : OFF
MENU TIMEOUT : OFF
BLINK CURSOR : OFF
DOME ANSWER : ON
SAVE AND EXIT (ESC TO CANCEL)
MOTOR SETUP
PROPORTIONAL P/T : ON
P/T MODE : NORMAL
SAVE AND EXIT (ESC TO CANCEL)
PROPORTIONAL P/T: enable (ON), disable (OFF), when this function is enabled the pan and tilt
speed of camera depends on actual zoom set;
P/T MODE: set the pan and tilt speed mode, available SLOW, NORMAL, TURBO:
WARNING!
The TURBO MODE can be also turned on with use of the PROGRAM button from the KBD40
keyboard or press CTRL button from the KBD70 keyboard.
INPUT PASSWORD
PASSWORD
A B C D E F G H I J
K L M N O P Q R S T
U V W X Y Z 0 1 2 3
4 5 6 7 8 9 ( )
WARNING!
h3) ORGIN CHECK: when you find the wrong position of the dome during operation , execute this
origin check and the dome camera will arrange the right position after the origin check operation. To
execute the ORGIN CHECK function enter to the menu and select OK.
h5) PASSWORD ENABLE: ON - requires password to enter to the menu, OFF - disable password.
h6) MENU TIME OUT: ON - the menu is displayed for 5 minutes, OFF - display menu for
unlimited time.
h8) DOME ANSWER: ON - this option is helpful to escape the collision of the command on RS-485
bus, OFF - no acknowledgement command from the dome.
SYSTEM INFORMATION
CAMERA TYPE :
H/W VERSION : UV3.00
ROM VERSION : RV3.023-C
PROTOCOL : N PROTOCOL
BAUDRATE : 9600
EXIT(ESC TO EXIT
This menu provides essential information about the camera. The values shown here cannot be
modified. You can determine the camera module information, software and hardware version as well
as telemetry protocol settings.
The FUNCTION RUN menu allows you to execute the function without using the function keys like
Preset, Pattern, Tour or Scan.
PRESET : 001
PATTERN : ---
TOUR : 001
SCAN : ---
HOME
AUTO PAN
RELAY OUT : ----
EXIT (ESC TO CANCEL)
WARNING!
To execute the function you should store it first.
Before entering FUNCTION RUN menu turn off the TURBO mode.
The RELAY OUT function can be operated only when the relay output setup has time in the
ALARM menu.
NVC-MSD322DN high-speed mini dome camera may be ceiling-mounted (either with NVC-CM22C
bracket or without), wall-mounted (with NVB-CM22W bracket) or dropped ceiling tiles (with NVH-
MSDHKIT bracket).
High-speed mini dome camera should be mounted only by qualified personnel and according to
the rules provided by user’s manual.
b) Mounting diagram
c) Installation
Camera base should be mounted in a place which can provide a proper support. It should withstand at
least minimal load of 1,3 kg.
Select place located on a flat surface (ceiling), in which the camera will be installed. Choose drilling
spots matching the holes located in the camera base (helpful template attached). Drill 4 holes in the
ceiling, with their diameter corresponding to the wall plug diameter and drill an additional hole for the
cable entry.
Connect the power supply cables, video and remote control cables, alarm input and outputs, relay
outputs going to the interconnection blocks. Then, put the cables through the hole in the ceiling. Next,
screw on the camera base to the flat surface using four wall plugs. After checking the stability of
mounted device, put and a screw on camera housing.
NVC-MSD322DN camera may be also mounted using bracket support. In this case either wall (with
NVB-CM22W bracket) or ceiling (with NVH-MSDHKIT bracket) mounting is possible.
b) Mounting
Camera base should be mounted in a place which can provide a proper support. It should withstand at
least minimal load of 1,7 kg.
PART 2 - Mounting
1. Attach the mounting base (4) and mounting plate (3) to wall or ceiling by using the mounting screw
(5) and wall plugs (1).
2. Roll the sealing tape onto both threaded endings of the bracket (about 20 times). Seal the connec-
tion with silicon paste if needed.
3. Attach the bracket (with sealing tape) to mounting base (4).
4. Pull the needed cables through bracket (6, 7) and mounting base (4).
5. Attach the camera adapter (8) to the pipe.
6. Attach mounting base (4) and camera adapter (8) with counter-screws (10).
7.Attach camera base to camera adapter (8) with mounting screws (12).
8. Put on the camera housing using screws attached.
c) Mounting scheme
Ceiling
Wall
Box
Cables Cables
d) Brackets specifications
Wall
Technical data
Bracket 1”
Substance Aluminium/steel
Max load about 5 kg
Net weight 1,3 kg
Gross weight 1.7 kg
NVC-MSD322DN camera may be mounted in dropped ceiling tiles, using NVH-MSDHKIT mini
bracket.
b) Mounting
Camera base should be mounted in a place which can provide a proper support. It should withstand
at least minimal load of 2 kg.
PART 2 - Mounting
WARNING!
To increase the safety level during installation, please attach the black stripe on the mask to
the bracket using appropriate hole in the bracket. Additionally, please attach the bracket to the
mounting surface, with the help of included steel wire. Connection should be performed as
depicted to below.
NVC-MSD322DN/O high-speed mini dome camera may be ceiling-mounted (either with NVB-
SD40CB bracket), wall-mounted (with NVB-SD40WB or NVB-SD40PWB 230 bracket).
High-speed mini dome camera should be mounted only by qualified personnel and according to
the rules provided by user’s manual.
a1). Dimensions
1 Wall bracket 1
2 Hex screw 2
3 Locking nut 1
4 Bush 1
5 Additional bushing plug 1
6 Service hole plate 1
7 Service plate screw 2
WARNING!: Because of safety conditions it is recommended to install wall bracket with housing and
camera on the wall with load capacity above 25 kg.
Wall bracket can be mounted directly to the wall or with additional mounting base. In case of using
mounting base using additional tapping screws with plastic anchors should be provided. It is not pos-
sible to use the ones included in a package.
1. Select suitable mounting location and lead all cables in such a way that they are in a centre of
the bracket once it is mounted.
2. Mark mounting position and drill 4 holes for plastic anchors.
3. In case of using the mounting base use additional anchors and screws and fix the base to the
wall.
4. Unscrew 2 screws (6) of the service hole plate (7).
5. Feed all cables through service hole.
6. Seal the bracket edge with silicon.
7. Screw on wall bracket to the wall using 4 tapping screws witch plastic anchors or screw on to
the mounting base using nuts and washers included in the mounting kit.
8. Feed the housing cable through the bracket (refer to housing manual).
9. Seal housing and bracket connection with teflon tape (refer to housing manual).
10. Screw on housing to the wall bracket using locking nut (3) and secure it with hex screw.
11. Attach the housing to the wall bracket using safety wire.
12. Connect all signal and power cables.
Put excessive cables into bracket interior and screw on service hole plate
a1). Dimensions
1 Base 1
2 Hex screw 2
3 Locking nut 1
4 Bush 1
5 Safety wire 1
7 Pipe 1
8 Threaded sleeve 1
WARNING!: Because of safety conditions it is recommended to install wall bracket with housing
and camera on the wall with load capacity above 25 kg.
1. Select suitable mounting location and lead all cables such a way they are in a centre of the
bracket once it is mounted.
2. Mark mounting position and drill 3 holes for plastic anchors.
3. Seal the base edge (1) with silicon
4. Feed all cables through base (1).
5. Screw on base (1) to the ceiling using 3 tapping screws witch plastic anchors.
6. Feed the housing cable (refer to housing manual) through the bracket pipe (7).
7. Seal housing and bracket connection with teflon tape (refer to housing manual).
8. Screw on housing to the bracket pipe (7) using threaded sleeve (8) and secure it with hex
screw.
9. Attach the bracket pipe (7) to the base (1) using safety wire (5).
10. Connect all signal and power cables.
11. Put excessive cables into pipe interior and screw on pipe (7) to the base (1) using locking nut
(3). Secure the nut with a hex screw.
If the equipment has been damaged during transport or is incomplete, the contents of the package
should be packed back to the original box. Contact the local NOVUS distributor for further assistance
c). Specifications
Model NVB-SD40PWB/230
Type Wall mount
Construction
Aluminum cast, internal construction elements - steel
material
Housing color Beige
Degree of
IP 66
protection
Power supply 230 VAC
Operating
-45 °C ~ 50 °C
temperature
Dimensions (mm) 215 x 194 x 270 (details in section 3.2)
Weight 3,8 kg
No Name Quantity
1 Screw (M5 x 15) 4
2 Front part 1
3 Screw (M4 x 8) 4
4 Hinge Ass’y 1
5 Rubber Gasket 1
6 Screw (M4 x 6) 4
7 Transformer 1
8 Mounting base 1
9 Hinge screw (M4 x 4) 1
10 PG Bushing 2
11 PCB Ass’y 1
12 Screw (M3 x 8) 4
13 Nut 1
14 Set screw 1
15 Bush 1
16 Set screw 1
c2). Dimensions
Terminal connection board is one of the internal bracket elements. It contains terminals for camera
module service and terminals CON1~CON9 for housing service. Housing and camera modul con-
trolled via bundle of cables attached to the housing (refer to the housing manual).
Additionally board is equipped with 1,6 A fuse for transformer protection and surge protection device
for electronic elements of the board and camera protection..
Transformer
Surge protection
1,6 A fuse
PCB
AC24V+
AC24V-
CON1 – factory connected CON4– for one connector of the cable bunch
24VAC – from transformer AC24+ 24VAC+ heater and fan power supply
AC24- 24VAC- heater and fan power supply
CON2 – for signal and power cables con-
nection
AC24+ 24VAC output CON5 - for one connector of the cable bunch
ALM3 Alarm input no 3 NC1 Relay output no.1 contact normally closed
ALM4 Alarm input no 4 NO1 Relay output no.1 contact normally open
GND Ground
COM1 Common output of relay no 1 CON7 - for one connector of the cable bunch
NO1 NO relay output no 1 NC2 Relay output no.2 contact normally closed
COM2 Common output of relay no 2 NO2 Relay output no.2 contact normally open
AC24- 24VAC- camera power supply 230 VAC power supply connection
GND ground
485B- RS-485 (-) input
485A+ RS-485(+) input
GND Ground
1. Select suitable mounting location and lead all cables such a way they could be leaded into the
bracket once it is mounted.
2. Mark mounting position and drill 4 holes for plastic anchors.
3. Screw on base (8) to the wall using 4 tapping screws witch plastic anchors.
4. Unscrew 4 screws (1) fixing front part of the bracket (2) and turn aside (it is equipped with the hinge).
5. Feed on necessary cables through the bushing (10).
6. Connect wires to appropriate connectors marked CON2 and CON8. Pay attention to proper polarization.
Screw the Earthing wire to the base and next to the transformer. The following sign is near to this point.
7. Feed on bunch of the wires with connectors from housing through the bracket.
8. Protect the housing against collapsing to fastening the snap hook with the bracket
9. Gently fasten the housing to the bracket with the nut (13). Do not use any tool.
10. Connect connectors to their sockets on the PCB. Connect any additional wires if necessary and check
system operation after power on..
Video cable
Cable bunch
connectors
Bracket earthing
connection
230VAC
connection
RS-485, alarm-in,
alarm-out connectors
11. Lock front part of the bracket. Pay attention to the rubber gasket (5) position. Tighten 4 screws (1).
12. Gently tighten the nut (13) using the spanner. Secure the nut using hex screw (14).
APPENDIX 1
APPENDIX 1
CAMA-III mini LANGUAGE SETTING PROCEDURE MENU
The procedure presented below shows how to go back to the English language in the CAMA-III mini
menu in case of selecting any other language by mistake.
APPENDIX 2
11 + ON BLC on (AE auto1 mode) 11 + OFF BLC off (AE auto1 mode)
12 + ON Digital Zoom on (According 12 + OFF Digital Zoom off
to digital zoom setting)
2011-06-06