100

101
102
110
111
112
113
114
115
116
117
118
120
121
122
123
124
125
126
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
150
151
152
153
154

Medical
Personal Emergency
Fail to report in
Fire
Smoke
Combustion
Water Flow
Heat
Pull Station
Duct
Flame
Near Alarm
Panic
Duress
Silent
Audible
Duress Access granted
Duress Egress granted
Hold-up suspicion print
Burglary
Perimeter
Interior
24 Hour (Safe)
Entry/Exit
Day/Night
Outdoor
Tamper
Near alarm
Intrusion Verifier
General Alarm
Polling loop open
Polling loop short
Expansion module failure
Sensor tamper
Expansion module tamper
Silent Burglary
Sensor Supervision Failure
24 Hour Non-Burglary
Gas detected
Refrigeration
Loss of heat
Water Leakage

A non-specific medical condition exists


Emergency Assistance request
A user has failed to activate a monitoring device
A non-specific fire alarm condition exists
An alarm has been triggered by a smoke detector
An alarm has been triggered by a combustion detector
An alarm has been triggered by a water flow detector
An alarm has been triggered by a heat detector
A pull station has been activated
An alarm has been triggered by a duct detector
An alarm has been triggered by a flame detector
A near-alarm condition has been detected on a fire sensor
A non-specific hold-up alarm exists
A duress code has been entered by a user
A silent hold-up alarm exists
An audible hold-up alarm exists
A duress code has been entered and granted at an entry door
A duress code has been entered and granted at an exit door
A user has activated a trigger to indicate a suspicious condition
A burglary zone has been violated while armed
A perimeter zone has been violated while armed
An interior zone has been violated while armed
A 24 hour burglary zone has been violated
An Entry/Exit zone has been violated while armed
An trouble by Day / alarm by Night zone has been violated while armed
An outdoor burglary zone has been violated while armed
A burglary zone has been tampered with while armed
A burg sensor has detected a condition which will cause it to go into alarm if the condition worsens
The specified zone has verified that an intrusion has occurred
The specified zone is in an alarm condition
An open circuit condition has been detected on a polling loop while the system was armed
A short circuit condition has been detected on a polling loop while the system was armed
A general failure condition has been detected on an expansion module while the system was armed
A sensor's tamper has been violated (case opened)
An expansion module's tamper has been violated (cabinet opened)
A burglary zone has been violated while armed with no audible notification produced
A sensor's supervisory circuit has reported a failure while the system was armed
A non-burglary zone has been faulted
The gas detector assigned to the specified zone has reported a fault condition
The refrigeration detector assigned to the specified zone has reported a fault condition
The temperature detector assigned to the specified zone has reported a fault condition
The water leak detector assigned to the specified zone has reported a fault condition

155
156
157
158

Foil Break
Day Trouble
Low bottled gas level
High temp

The specified zone which is assigned to foil used as glass break detection has reported a fault condition
The specified zone which monitors trouble by day has reported a fault condition while disarmed
The gas level detector assigned to the specified zone has reported a fault condition
The over-temperature detector assigned to the specified zone has reported a fault condition

159
161
162
163
200
201
202

Low temp
Loss of air flow
Carbon Monoxide detected
Tank level
Fire Supervisory
Low water pressure
Low CO2

The under-temperature detector assigned to the specified zone has reported a fault condition
The air flow detector assigned to the specified zone has reported a fault condition
The carbon monoxide detector assigned to the specified zone has reported a fault condition
The tank level detector assigned to the specified zone has reported a fault condition
The supervisory circuit of the specified fire zone has reported a fault condition
The water pressure sensor assigned to the specified zone has reported a fault condition
The CO2 pressure sensor assigned to the specified zone has reported a fault condition

203
204
205
206
300
301
302
303
304
305
306
307
308
309
310
311
312
313

Gate valve sensor


Low water level
Pump activated
Pump failure
System Trouble
AC Loss
Low system battery
RAM Checksum bad
ROM checksum bad
System reset
Panel programming changed
Self-test failure
System shutdown
Battery test failure
Ground fault
Battery Missing/Dead
Power Supply Overcurrent
Engineer Reset

314
320
321
322
323
324
325
326
327
330
331
332
333
334
335
336
337
338
339

Radio battery charger failure


Sounder/Relay
Bell 1
Bell 2
Alarm relay
Trouble relay
Reversing relay
Notification Appliance Ckt. # 3
Notification Appliance Ckt. #4
System Peripheral trouble
Polling loop open
Polling loop short
Expansion module failure
Repeater failure
Local printer out of paper
Local printer failure
Exp. Module Power Loss
Exp. Module Low Battery
Exp. Module Power On / Reset

The gate valve sensor in the fire sprinkler system assigned to the specified zone has reported a fault condition
The water level sensor assigned to the specified zone has reported a fault condition
The pump activity detector assigned to the specified zone has reported an active condition
A pump output monitor assigned to the specified zone has reported a fault condition
A general system trouble condition has been reported by the specified zone
AC power loss has been detected at a control or expansion module while the system was disarmed
A battery has failed a load test while the system was disarmed
A test of the system's memory has failed
A test of the system's executable memory has failed
The system has reset and restarted
The programmed configuration of the panel has changed
The system has failed a self-test
The system has been shut down and has stopped functioning
The system backup battery has failed a load test while the system was disarmed
The panel has detected a ground fault condition
The system has detected that the backup battery is either missing or completely discharged.
The system power supply has reported an excessive current draw condition
The specified service person has issued a system reset
The system's primary power supply has failed a supervision test. Radio devices indicate this when the backup
battery charging circuit has failed its supervision test
A trouble condition exists in the system's sounder/relay circuit
A trouble condition exists in the primary bell circuit
A trouble condition exists in the secondary bell circuit
A trouble condition exists in the system's alarm relay circuit
A trouble condition exists in the system's trouble relay circuit
The specified TELCO reversing relay has reported a trouble condition
A trouble condition exists in the bell #3 circuit
A trouble condition exists in the bell #4 circuit
A system peripheral device has reported a trouble condition
An open circuit condition has been detected on a polling loop while the system was disarmed
A short circuit condition has been detected on a polling loop while the system was disarmed
A general failure condition has been detected on an expansion module while the system was disarmed
A repeater in the system has reported a failure condition while the system was disarmed
The printer attached to the panel has reported an Out Of Paper condition
The printer attached to the panel has reported a failure condition
An expansion module has detected a DC power loss
An expansion module has detected a low battery condition
An expansion module has reset

341 Exp. Module Tamper


342 Exp. Module AC Loss
343 Exp. Module self-test fail
344
350
351
352
353
354
355
356
357
358
370
371
372
373
374
375
376
377

RF Receiver Jam Detect


Communication Path Failure
Telco 1 fault
Telco 2 fault
Long Range Radio xmitter fault
Failure to communicate event
Loss of Radio ECP supervision
Loss of central polling
Long Range Radio VSWR problem
Periodic Comm Test Fail /Restore
Protection loop
Protection loop open
Protection loop short
Fire trouble
Exit error alarm (zone)
Panic zone trouble
Hold-up zone trouble
Swinger Trouble

378
380
381
382
383
384
385
386
387
388
389
391
392
393
394
400
401
402
403
404
405
406
407

Cross-zone Trouble
Sensor trouble
Loss of supervision - RF
Loss of supervision - RPM
Sensor tamper
RF low battery
Smoke detector Hi sensitivity
Smoke detector Low sensitivity
Intrusion detector Hi sensitivity
Intrusion detector Low sensitivity
Sensor self-test failure
Sensor Watch trouble
Drift Compensation Error
Maintenance Alert
CO Detector needs replacement
Open/Close
O/C by user
Group O/C
Automatic O/C
Late to O/C (Note: use 453 or 454 instead)
Deferred O/C (Obsolete- do not use )
Cancel
Remote arm/disarm

An expansion module has detected its tamper switch has been faulted
An expansion module has detected the loss of AC power
An expansion module has failed a self-test
An RF receiver has detected the presence of a jamming signal which prevents it from receiving normal signals
from the system RF devices
The system has experienced difficulties communicating with the central station
The system has detected a fault on the primary dial-up line
The system has detected a fault on the secondary dial-up line
A fault has been detected in the long range radio subsystem
The system was unable to communicate an event to the central station
The radio has not reported in its designated supervision interval
The radio has detected a loss in the polling signal from it's associated receiver
The Long Range Radio has reported a transmitter/antenna problem
A periodic Communication path test has failed
The specified protection loop has reported a trouble condition
The specified protection loop has reported an open-loop trouble condition
The specified protection loop has reported a shorted-loop trouble condition
A fire sensor has detected a trouble condition on the specified zone while the system was disarmed
An exit error condition has been reported for the specified alarm zone
The system has detected a trouble condition on the panic zone
The system has detected a trouble condition on the hold-up zone
A fault has occurred on a zone that has been shut down due to excessive alarms
The specified zone in a cross-zone configuration has faulted without a fault on its corresponding cross-zone in
a specific time period
The specified sensor has reported a trouble condition
The specified zone has failed to report in during its designated supervision period
An Remote Polled Module assigned to the specified zone has failed supervision
The tamper switch on the specified sensor has been faulted
The specified battery powered RF zone has reported a low battery condition
A smoke detector's sensitivity level has drifted to the upper limit
A smoke detector's sensitivity level has drifted to the lower limit
An intrusion detector's sensitivity level has drifted to the upper limit
An intrusion detector's sensitivity level has drifted to the lower limit
The specified sensor has failed a self-test
A motion sensor has not been triggered within a pre-defined time interval
A smoke detector cannot automatically adjust its sensitivity
The specified zone requires maintenance
The specified Carbon Monoxide detector has reached end-of-life
The specified user has disarmed/armed the system
The specified user has disarmed/armed the system
A group of zones has been armed or disarmed
A partition has been automatically armed or disarmed
Late to Open or Close
Deferred Open or Close
The specified user has cancelled the previously reported alarm condition
The specified user has armed or disarmed the system from off-premises

408
409
411
412
413
414
415
416
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
441
442
443
450

Quick arm
Keyswitch O/C
Callback request made
Successful download/access
Unsuccessful access
System shutdown command received
Dialer shutdown command received
Successful Upload
Access denied
Access report by user
Forced Access
Egress Denied
Egress Granted
Access Door propped open
Access point Door Status Monitor trouble
Access point Request To Exit trouble
Access program mode entry
Access program mode exit
Access threat level change
Access relay/trigger fail
Access RTE shunt
Access DSM shunt
Second Person Access
Irregular Access
Armed STAY
Keyswitch Armed STAY
Armed with System Trouble Override
Exception O/C

The specified user has quick-armed the system


The specified user has armed or disarmed the system using a keyswitch
A remote site (central station) has requested the panel call it back
The configuration data of the system has been successfully downloaded
A number of failed attempts have been made to remotely access the system
A central station has sent a system shutdown command to the panel
A central station has sent a dialer shutdown command to the panel
The configuration data of the system has been successfully uploaded
The access control system has denied access to the specified user
The specified access control door has been forced open
The access control system has denied egress to the specified user
The access control system has granted egress for the specified user
The specified access control door has been held open
The specified Access Point's Door Status Monitor has reported a trouble condition to the panel
The specified Access Point's Request To Exit zone has reported a trouble condition to the panel
The access control system has been put into program mode
The access control system has exited program mode
The access control system's threat level has been changed
The specified access control output device has failed to operate properly
The specified Request To Exit zone has been shunted and will no longer report activity
The specified Door Status Monitor zone has been shunted and will no longer report activity
A second person has accessed an access point conforming to Two-Man-Rule requirements
The specified user has armed the system in STAY mode
The specified user has armed the system in STAY mode using a keyswitch
The specified user has armed the system while overriding a trouble condition
The system has been armed or disarmed outside of the configured time window

451 Early O/C

The system has been disarmed/armed by the specified user before the configured time window has started

452
453
454
455
456
457
458
459
461
462
463
464
465
466
501

The system has been disarmed/armed by the specified user after the configured time window has ended
The system has failed to have been disarmed during the designated time window
The system has failed to be armed during the designated time window
The system has failed to automatically arm itself at the designated time
The system has been only partially armed by the specified user
The specified user has made an error exiting the premises after arming the system
A user has disarmed the system after an alarm has occurred
The system had been armed within the last xx minutes

Late O/C
Failed to Open
Failed to Close
Auto-arm Failed
Partial Arm
Exit Error (user)
User on Premises
Recent Close
Wrong Code Entry
Legal Code Entry
Re-arm after Alarm
Auto-arm Time Extended
Panic Alarm Reset
Service On/Off Premises
Access reader disable

A user has successfully requested that the system delay automatically arming
The specified panic zone has been reset
A service person has entered or left the premises
The credential reader on the specified access point has been disabled

520
521
522
523
524
525
526
527
531
532
551
552
553
570
571
572
573
574

Sounder/Relay Disable
Bell 1 disable
Bell 2 disable
Alarm relay disable
Trouble relay disable
Reversing relay disable
Notification Appliance Ckt. # 3 disable
Notification Appliance Ckt. # 4 disable
Module Added
Module Removed
Dialer disabled
Radio transmitter disabled
Remote Upload/Download disabled
Zone/Sensor bypass
Fire bypass
24 Hour zone bypass
Burg. Bypass
Group bypass

575 Swinger bypass


576 Access zone shunt
577
578
579
601
602
603
604
605
606
607
608
609
611
612
613
614
615
616
621
622
623
624
625
626

Access point bypass


Vault Bypass
Vent Zone Bypass
Manual trigger test report
Periodic test report
Periodic RF transmission
Fire test
Status report to follow
Listen-in to follow
Walk test mode
Periodic test - System Trouble Present
Video Xmitter active
Point tested OK
Point not tested
Intrusion Zone Walk Tested
Fire Zone Walk Tested
Panic Zone Walk Tested
Service Request
Event Log reset
Event Log 50% full
Event Log 90% full
Event Log overflow
Time/Date reset
Time/Date inaccurate

The specified sounder or relay has been disabled


The specified output for Bell 1 has been disabled
The specified output for Bell 2 has been disabled
The specified alarm relay has been disabled
The specified trouble relay has been disabled
The specified reversing relay has been disabled
The specified output for Bell 3 has been disabled
The specified output for Bell 4 has been disabled
The specified access control module has been added to the system
The specified access control module has been removed from the system
The specified dialer has been disabled
The specified radio transmitter has been disabled
Remote configuration has been enabled
The specified zone or sensor has been bypassed
The specified fire zone has been bypassed
The specified 24 hour zone has been bypassed
The specified burglary zone has been bypassed
A group of zones has been bypassed
The specified zone which has reported an excessive number of faults/restores in a short period of time has
been bypassed
The specified zone in the access control system has been shunted and will no longer report activity
The specified access point in the access control system has been bypassed and will allow the door to open
(unsecured)
The specified vault zone has been bypassed
The specified vent zone has been bypassed and will no longer report any activity
A test report has been triggered manually
A periodic test report has been triggered
A periodic RF path test report has been triggered
The specified user has initiated a test of the fire alarm zones
The system is about to activate a 2-way audio session
The specified user has placed the system into the walk-test mode for testing purposes
A periodic test has been triggered but the fire system has a trouble condition present
A video look-in session is about to begin
The specified point tested successfully
The specified point has not been tested
The specified intrusion zone has been successfully walk-tested
The specified fire zone has been successfully walk-tested
The specified panic zone has been successfully walk-tested
A request has been made for system servicing
The event log has been reset and all stored events have been discarded
The event log is 50% full
The event log is 90% full
The event log has overflowed and events have been lost
The time and date have been reset to a new value by the specified user
The system time and date is known to be in error

627 Program mode entry


628 Program mode exit
629
630
631
632
641
642
651
652
653
654
655
703
704
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779

32 Hour Event log marker


Schedule change
Exception schedule change
Access schedule change
Senior Watch Trouble
Latch-key Supervision
Reserved for Ademco Use
Reserved for Ademco Use
Reserved for Ademco Use
System Inactivity
User Code X modified by Installer
Auxiliary #3
Installer Test
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message

The system has been placed into program mode


The system has exited program mode
In the last 31.9 hours (1 and 1/3 days), nothing has been posted to the event log. There is nothing new to
read. Does not send to central station and only occurs in the Vista-20/SE and FA sister products.
The specified fire/burglary schedule has been changed
The time schedule for event reporting by exception has been changed
The specified access control schedule has been changed
A person has not activated a motion sensor in a specified period
A child has disarmed the system (after school)

System has not been operated for x days


The Installer has modified the specified User's code

780
781
782
783
784
785
786
787
788
789
796
798
900
901
902
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
954

User Assigned CID Message


User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
User Assigned CID Message
Unable to output signal (Derived Channel
STU Controller down (Derived Channel)
Download Abort
Download Start/End
Download Interrupted
Auto-close with Bypass
Bypass Closing
Fire Alarm Silence
Supervisory Point test Start/End
Hold-up test Start/End
Burg. Test Print Start/End
Supervisory Test Print Start/End
Burg. Diagnostics Start/End
Fire Diagnostics Start/End
Untyped diagnostics
Trouble Closing (closed with burg. Durin exit)
Access Denied Code Unknown
Supervisory Point Alarm
Supervisory Point Bypass
Supervisory Point Trouble
Hold-up Point Bypass
AC Failure for 4 hours
Output Trouble
User code for event
Log-off
Communication Failure

999 1 and 1/3 Day No Read Log

The specified Downloader ID has aborted a download sequence in progress


Downloader has started or ended a download sequence to the panel
A download sequence has been interrupted
An auto-close sequence has been started and the specified zone has been bypassed
The fire alarm has been silenced
A fire supervisory device has been tested
The specified user has started or ended a hold-up test
The printed progress of a burglary test has been started or ended
The printed progress of a supervisory test has been started or ended
A burglary system diagnostic test has been started or ended
A fire system diagnostic test has been started or ended

Access has been denied because the system did not recognize the supplied access code as valid
The specified supervisory point has reported an alarm condition
The specified supervisory point has been bypassed
The specified supervisory point has reported a trouble condition
The specified hold-up point has been bypassed
There has been a loss of AC power for at least four hours
The specified output has reported a trouble condition
This message contains the ID of the user who triggered the previous event
The specified user has logged-off of the system
Comm fail to the primary (zone 951) or secondary (zone 952) 7810iR-ent in private LAN mode
In the last 31.9 hours (1 and 1/3 days), nothing has been posted to the event log. There is nothing new to
read. Does not send to central station and only occurs in the Vista-20/SE and FA sister products.