101
102
110
111
112
113
114
115
116
117
118
120
121
122
123
124
125
126
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
150
151
152
153
154
Medical
Personal Emergency
Fail to report in
Fire
Smoke
Combustion
Water Flow
Heat
Pull Station
Duct
Flame
Near Alarm
Panic
Duress
Silent
Audible
Duress Access granted
Duress Egress granted
Hold-up suspicion print
Burglary
Perimeter
Interior
24 Hour (Safe)
Entry/Exit
Day/Night
Outdoor
Tamper
Near alarm
Intrusion Verifier
General Alarm
Polling loop open
Polling loop short
Expansion module failure
Sensor tamper
Expansion module tamper
Silent Burglary
Sensor Supervision Failure
24 Hour Non-Burglary
Gas detected
Refrigeration
Loss of heat
Water Leakage
155
156
157
158
Foil Break
Day Trouble
Low bottled gas level
High temp
The specified zone which is assigned to foil used as glass break detection has reported a fault condition
The specified zone which monitors trouble by day has reported a fault condition while disarmed
The gas level detector assigned to the specified zone has reported a fault condition
The over-temperature detector assigned to the specified zone has reported a fault condition
159
161
162
163
200
201
202
Low temp
Loss of air flow
Carbon Monoxide detected
Tank level
Fire Supervisory
Low water pressure
Low CO2
The under-temperature detector assigned to the specified zone has reported a fault condition
The air flow detector assigned to the specified zone has reported a fault condition
The carbon monoxide detector assigned to the specified zone has reported a fault condition
The tank level detector assigned to the specified zone has reported a fault condition
The supervisory circuit of the specified fire zone has reported a fault condition
The water pressure sensor assigned to the specified zone has reported a fault condition
The CO2 pressure sensor assigned to the specified zone has reported a fault condition
203
204
205
206
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
320
321
322
323
324
325
326
327
330
331
332
333
334
335
336
337
338
339
The gate valve sensor in the fire sprinkler system assigned to the specified zone has reported a fault condition
The water level sensor assigned to the specified zone has reported a fault condition
The pump activity detector assigned to the specified zone has reported an active condition
A pump output monitor assigned to the specified zone has reported a fault condition
A general system trouble condition has been reported by the specified zone
AC power loss has been detected at a control or expansion module while the system was disarmed
A battery has failed a load test while the system was disarmed
A test of the system's memory has failed
A test of the system's executable memory has failed
The system has reset and restarted
The programmed configuration of the panel has changed
The system has failed a self-test
The system has been shut down and has stopped functioning
The system backup battery has failed a load test while the system was disarmed
The panel has detected a ground fault condition
The system has detected that the backup battery is either missing or completely discharged.
The system power supply has reported an excessive current draw condition
The specified service person has issued a system reset
The system's primary power supply has failed a supervision test. Radio devices indicate this when the backup
battery charging circuit has failed its supervision test
A trouble condition exists in the system's sounder/relay circuit
A trouble condition exists in the primary bell circuit
A trouble condition exists in the secondary bell circuit
A trouble condition exists in the system's alarm relay circuit
A trouble condition exists in the system's trouble relay circuit
The specified TELCO reversing relay has reported a trouble condition
A trouble condition exists in the bell #3 circuit
A trouble condition exists in the bell #4 circuit
A system peripheral device has reported a trouble condition
An open circuit condition has been detected on a polling loop while the system was disarmed
A short circuit condition has been detected on a polling loop while the system was disarmed
A general failure condition has been detected on an expansion module while the system was disarmed
A repeater in the system has reported a failure condition while the system was disarmed
The printer attached to the panel has reported an Out Of Paper condition
The printer attached to the panel has reported a failure condition
An expansion module has detected a DC power loss
An expansion module has detected a low battery condition
An expansion module has reset
378
380
381
382
383
384
385
386
387
388
389
391
392
393
394
400
401
402
403
404
405
406
407
Cross-zone Trouble
Sensor trouble
Loss of supervision - RF
Loss of supervision - RPM
Sensor tamper
RF low battery
Smoke detector Hi sensitivity
Smoke detector Low sensitivity
Intrusion detector Hi sensitivity
Intrusion detector Low sensitivity
Sensor self-test failure
Sensor Watch trouble
Drift Compensation Error
Maintenance Alert
CO Detector needs replacement
Open/Close
O/C by user
Group O/C
Automatic O/C
Late to O/C (Note: use 453 or 454 instead)
Deferred O/C (Obsolete- do not use )
Cancel
Remote arm/disarm
An expansion module has detected its tamper switch has been faulted
An expansion module has detected the loss of AC power
An expansion module has failed a self-test
An RF receiver has detected the presence of a jamming signal which prevents it from receiving normal signals
from the system RF devices
The system has experienced difficulties communicating with the central station
The system has detected a fault on the primary dial-up line
The system has detected a fault on the secondary dial-up line
A fault has been detected in the long range radio subsystem
The system was unable to communicate an event to the central station
The radio has not reported in its designated supervision interval
The radio has detected a loss in the polling signal from it's associated receiver
The Long Range Radio has reported a transmitter/antenna problem
A periodic Communication path test has failed
The specified protection loop has reported a trouble condition
The specified protection loop has reported an open-loop trouble condition
The specified protection loop has reported a shorted-loop trouble condition
A fire sensor has detected a trouble condition on the specified zone while the system was disarmed
An exit error condition has been reported for the specified alarm zone
The system has detected a trouble condition on the panic zone
The system has detected a trouble condition on the hold-up zone
A fault has occurred on a zone that has been shut down due to excessive alarms
The specified zone in a cross-zone configuration has faulted without a fault on its corresponding cross-zone in
a specific time period
The specified sensor has reported a trouble condition
The specified zone has failed to report in during its designated supervision period
An Remote Polled Module assigned to the specified zone has failed supervision
The tamper switch on the specified sensor has been faulted
The specified battery powered RF zone has reported a low battery condition
A smoke detector's sensitivity level has drifted to the upper limit
A smoke detector's sensitivity level has drifted to the lower limit
An intrusion detector's sensitivity level has drifted to the upper limit
An intrusion detector's sensitivity level has drifted to the lower limit
The specified sensor has failed a self-test
A motion sensor has not been triggered within a pre-defined time interval
A smoke detector cannot automatically adjust its sensitivity
The specified zone requires maintenance
The specified Carbon Monoxide detector has reached end-of-life
The specified user has disarmed/armed the system
The specified user has disarmed/armed the system
A group of zones has been armed or disarmed
A partition has been automatically armed or disarmed
Late to Open or Close
Deferred Open or Close
The specified user has cancelled the previously reported alarm condition
The specified user has armed or disarmed the system from off-premises
408
409
411
412
413
414
415
416
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
441
442
443
450
Quick arm
Keyswitch O/C
Callback request made
Successful download/access
Unsuccessful access
System shutdown command received
Dialer shutdown command received
Successful Upload
Access denied
Access report by user
Forced Access
Egress Denied
Egress Granted
Access Door propped open
Access point Door Status Monitor trouble
Access point Request To Exit trouble
Access program mode entry
Access program mode exit
Access threat level change
Access relay/trigger fail
Access RTE shunt
Access DSM shunt
Second Person Access
Irregular Access
Armed STAY
Keyswitch Armed STAY
Armed with System Trouble Override
Exception O/C
The system has been disarmed/armed by the specified user before the configured time window has started
452
453
454
455
456
457
458
459
461
462
463
464
465
466
501
The system has been disarmed/armed by the specified user after the configured time window has ended
The system has failed to have been disarmed during the designated time window
The system has failed to be armed during the designated time window
The system has failed to automatically arm itself at the designated time
The system has been only partially armed by the specified user
The specified user has made an error exiting the premises after arming the system
A user has disarmed the system after an alarm has occurred
The system had been armed within the last xx minutes
Late O/C
Failed to Open
Failed to Close
Auto-arm Failed
Partial Arm
Exit Error (user)
User on Premises
Recent Close
Wrong Code Entry
Legal Code Entry
Re-arm after Alarm
Auto-arm Time Extended
Panic Alarm Reset
Service On/Off Premises
Access reader disable
A user has successfully requested that the system delay automatically arming
The specified panic zone has been reset
A service person has entered or left the premises
The credential reader on the specified access point has been disabled
520
521
522
523
524
525
526
527
531
532
551
552
553
570
571
572
573
574
Sounder/Relay Disable
Bell 1 disable
Bell 2 disable
Alarm relay disable
Trouble relay disable
Reversing relay disable
Notification Appliance Ckt. # 3 disable
Notification Appliance Ckt. # 4 disable
Module Added
Module Removed
Dialer disabled
Radio transmitter disabled
Remote Upload/Download disabled
Zone/Sensor bypass
Fire bypass
24 Hour zone bypass
Burg. Bypass
Group bypass
780
781
782
783
784
785
786
787
788
789
796
798
900
901
902
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
954
Access has been denied because the system did not recognize the supplied access code as valid
The specified supervisory point has reported an alarm condition
The specified supervisory point has been bypassed
The specified supervisory point has reported a trouble condition
The specified hold-up point has been bypassed
There has been a loss of AC power for at least four hours
The specified output has reported a trouble condition
This message contains the ID of the user who triggered the previous event
The specified user has logged-off of the system
Comm fail to the primary (zone 951) or secondary (zone 952) 7810iR-ent in private LAN mode
In the last 31.9 hours (1 and 1/3 days), nothing has been posted to the event log. There is nothing new to
read. Does not send to central station and only occurs in the Vista-20/SE and FA sister products.