CTI Data of Record Submission Instructions:

All manufacturer's that wish to join the CTI STD-201 program or the ECC Certification program must complete a Data of Record
The Data of Record template is provided for both (SI) and (IP) units. Data should begin in cell "N7"

The (SI) and (IP) versions of the Data of Record must both be completed and submitted to the CTI thermal certification program
The Reference Document shall be utilized to ensure the proper data is recorded in the Data of Record

In addition to the tabular data required, the Data of Record submission must include all of the required data parameters itemize
zip file and attached to each model.

1) CTI/ECC unit drawing package must be submitted illustrating overall dimensions, water inlet connection locati
air inlets (size & location), and air discharge location of product line
2) CTI/ECC drawing and photograph package for all fan options must be submitted
Drawing and photograph for each fan diameter (and type if multiple types are possible) will be prov
Drawing will include tabular data detailing all optional fans available for the given cooling tower mo
Data will include Blade Chord Width (at tip), hub diameter, seal disk diameter (central diameter wit
flow), number of blades, blade material, fan speed, fan model designation, and fan stack height(s)
given model
3) CTI/ECC drawing and photograph package for Eliminators must be submitted
Drawing will include tabular data detailing eliminator materials, model designations, and manufactu
4) CTI/ECC drawing and photograph package for Air Inlet Louvers must be submitted
Drawing will include tabular data detailing louver materials, model designations, and manufacturer
5) CTI/ECC drawing and photograph package for Wet Heat Transfer Media (Fill) must be submitted
Drawing will include tabular data detailing fill materials, model designations, and manufacturer(s)
6) CTI/ECC drawing and photograph package for Heat Exchanger must be submitted
Drawing will include tabular data detailing materials, model designations, and manufacturer(s)
7) CTI/ECC drawing and photograph package for Nozzles must be submitted
Drawing will include tabular data detailing nozzle materials, model designations, and manufacturer
8) CTI/ECC Accessory/Footnotes document must be submitted

gram must complete a Data of Record for all products.

o the CTI thermal certification program administrator.

ata of Record
the required data parameters itemized below. All of the data paramenters will be combined in a

mensions, water inlet connection location(s),

multiple types are possible) will be provided


vailable for the given cooling tower model
eal disk diameter (central diameter with blocked air
el designation, and fan stack height(s) available for a

s, model designations, and manufacturer(s)

model designations, and manufacturer(s)


a (Fill) must be submitted
el designations, and manufacturer(s)

esignations, and manufacturer(s)

model designations, and manufacturer(s)

CT/CC/EC
GENERIC (SI)

Product Number

Master product
number

Tested On

Rerated on

Created on

Last update on

Columns "A" through "M" shall only be completed by ECC or CTI admin
Participant completing there DOR's MUST not use these column

CT/CC/EC
GENERIC (SI)

Status

Participant
Name

ted by ECC or CTI administrator.


UST not use these column's

Product Name

Trade Name

Type of product

Range Name

BMG

CTI DOR
Reference
Sequence

1
2
3

Manufacturer

Product Line

Submission
Revision Date

Product Type

String

String

String

Boolean

Gene

Draft Type

Flow Type

Fan Type

Model Number

String

String

String

String

Nominal Water
Flow Rate

Nominal Temperature
Conditions

L/s
Decimal

C
String

General(GEN)

Number of
Cells

String

Number of Fans Number of Fan


per Cell
Motors Per Cell

Integer

Decimal

Total Nameplate Fan


Total Rated Fan Motor
Motor Power per
Power per Model
Model

kW
Decimal

kW
Decimal

Number of Pumps
per Cell

Integer

Total Nameplate
Pump Power per
Model

Total Rated
Pump Power
per Model

Flowrate of
Recirculating Water

Static Pressure at
Recirculating Water
Inlet

kW
Integer

kW
Decimal

L/s
Decimal

m
Decimal

Axial Fans

Overall Height of
Unit

Fan Diameter

Standard Fan
Center Hub or Seal
Disk Diameter

Fan stack Height

m
Decimal

m
Decimal

mm
Decimal

mm
Decimal

Axial Fans

Centrifug

Fan Stack Inlet


Area

Fan Stack
Throat Area

Fan Stack
Discharge Area

Fan Blade Pitch


Adjustement

m
Decimal

m
Decimal

m
Decimal

String

Fan Wheel
Outside
Diameter

Fan Wheel
Width

mm
Decimal

mm
Decimal

Centrifugal Fans

Eliminators

Fan Wheel
Fan Wheel
Fan Wheel
Fan Wheel
Eliminator
Housing Width Housing Outside Housing Inside
Housing
Eliminator Type Gross Area per
Dimension "A" Dimension "B" Dimension "C" Discharge Area
Cell

mm
Decimal

mm
Decimal

mm
Decimal

m
Decimal

String

m
Decimal

Air Inlet Louvers

Louver type

String

Louver Gross
Face Area per
cell

m
Decimal

No. Air Inlet


Air Inlet Height Louver Spacing
Faces per cell

Integer

mm
Decimal

mm
Decimal

Fill Type

String

Wet Heat Transfer Media

Fill Height

mm
Decimal

Counterflow No. Crossflow Air


of Fill Layers
travel

Integer

mm
Integer

Internal Cell
Lengh

Internal Cell
Width

Fill Total Gross


Face Area per
Cell

mm
Integer

mm
Integer

m
Decimal

r Media

Film Fill No. of


Sheets over
Cell Width

Film Fill No. of


Sheets over
Cell Length

No. Splash
Bars in Cross
Section

Splash Bars
Pattern

Integer

Integer

Integer

String

Splash Deck Heat Exchanger


No. of layers
Type

Integer

String

Number of Heat Heat Exchanger


Heat Exchanger
Exchangers per Total Number of
Plate Height
Cell
Plates
Heat Exchanger Heat Exchanger Heat Exchanger

Decimal

Integer

Number of
plates type A

Number of
plates type B

Number of
plates type C

Integer

Integer

Integer

mm
Decimal

Heat Exchanger

Heat Exchanger
Plate Width

mm
Decimal

Heat Exchanger Heat Exchanger


Plate Depth
Number of
Inside
Passes

mm
Decimal

Integer

Heat Exchanger Heat Exchanger


Number of
Number of Heat Exchanger
Rows or
Tubes or
Tube Diameter
Passes
Passes

Integer

Integer

mm
Decimal

Heat Exchanger Heat Exchanger Heat Exchanger


Heat Exchanger Heat Exchanger Heat Exchanger
Number of Inlet Inlet Nozzle
Number of
Width
Length
Surface Area
Nozzles
Size
Outlet Nozzles

mm
Decimal

mm
Decimal

m
Decimal

Integer

mm
Decimal

Integer

Water Distribution

Heat Exchanger Heat Exchanger


Heat Exchanger Heat Exchanger
Outlet Nozzle
Gross Free
Process Fluid Pressure Drop
Size
Area

mm
Decimal

m
Decimal

String

kPa
Decimal

Water
Distribution
Type

No. Inlet
Connections
per Cell

String

Integer

Water Distribution
Ratio of
Ratio of Prop
Centrifugal Fan
Fan Stack
Underside of
Wheel Housing Ratio of Air Inlet Gross
Throat Area to
No. Nozzles or Nozzle Height
Discharge Area Face Area to the Total
Wet Heat
Orifices per Cell above Media or
to Wet Heat
Gross Face Area of the
Transfer Media
Heat Exchanger
Transfer Media
Heat Transfer Media
Gross Face
Gross Face
Area
Area
mm
Integer
Integer
Decimal
Decimal
Decimal

Geometric Data

Geometric Data
Ratio of Fan Coverage Area to
Eliminator/Louver Area when projecting a
circle at 45o from fan inlet opening onto
Ratio of Fan Plenum Width to Fan Plenum
the Eliminator/Louver Face and
Length (See Appendix F, Fig D)
neglecting all portions of the projection
which fall beyond the cell boundaries
(See Appendix F, Fig A, B, and C)
Decimal

Decimal

Attached Files

Name of ZIP data file attached to this model

String

1
2

5
6
7
8
9

CT/CC/E
GENERIC

Product Number

Master product
number

Tested On

Rerated on

Created on

Last update on

Columns "A" through "M" shall only be completed by ECC or CTI


Participant completing there DOR's MUST not use these co

1
2

G
CT/CC/EC
GENERIC (IP)

Status

Participant
Name

Product Name

Trade Name

Type of product

Range Name

5
6
mpleted by7 ECC or CTI administrator.
's MUST not8 use these column's
9

BMG

CTI DOR
Reference
Sequence

Manufacturer

Product Line

Submission
Revision Date

Product Type

String

String

String

Boolean

1
2

5
6
7
8
9

1
2
3

Draft Type

Flow Type

Fan Type

Model Number

Nominal Water
Flow Rate

String

String

String

String

1
2

5
6
7
8
9

gpm
Decimal

X
1
2

5
6
7
8
9

AA

AB

General(GEN)

Nominal Temperature
Conditions

Number of
Cells

F
String

String

Number of Fans Number of Fan


per Cell
Motors Per Cell

Integer

Decimal

Total Nameplate Fan


Motor Power per
Model

HP
Decimal

AC

AD

AE

AF

Total Rated Fan Motor


Power per Model

Number of Pumps
per Cell

Total Nameplate
Pump Power per
Model

Total Rated
Pump Power
per Model

HP
Decimal

Integer

HP
Integer

HP
Decimal

1
2

5
6
7
8
9

AG

AH

AI

AJ

Flowrate of
Recirculating Water

Static Pressure at
Recirculating Water
Inlet

Overall Height of
Unit

Fan Diameter

gpm
Decimal

ft
Decimal

ft
Decimal

ft
Decimal

1
2

5
6
7
8
9

AK
1
2

5
6
7
8
9

AL

AM

AN

AO

Axial Fans

Standard Fan
Center Hub or Seal
Disk Diameter

Fan stack Height

Fan Stack Inlet


Area

Fan Stack
Throat Area

Fan Stack
Discharge Area

in
Decimal

in
Decimal

ft
Decimal

ft
Decimal

ft
Decimal

AP

AQ

AR

1
2

5
6
7
8
9

AS

AT

AU

Centrifugal Fans

Fan Blade Pitch


Adjustement

String

Fan Wheel
Outside
Diameter

Fan Wheel
Width

in
Decimal

in
Decimal

Fan Wheel
Fan Wheel
Fan Wheel
Housing Width Housing Outside Housing Inside
Dimension "A" Dimension "B" Dimension "C"

in
Decimal

in
Decimal

in
Decimal

AV
1
2

5
6
7
8
9

AW

AX

AY

AZ

Eliminators

Fan Wheel
Eliminator
Housing
Eliminator Type Gross Area per
Discharge Area
Cell

ft
Decimal

String

ft
Decimal

BA
Air Inlet Louvers

Louver type

String

Louver Gross
Face Area per
cell

ft
Decimal

No. Air Inlet


Faces per cell

Integer

BB

BC

BD

BE

Fill Type

Fill Height

String

in
Decimal

BF

BG

1
2
Air Inlet Louvers

5
6
7
8
9

Air Inlet Height Louver Spacing

in
Decimal

in
Decimal

Counterflow No. Crossflow Air


of Fill Layers
travel

Integer

in
Integer

BH
1
2

5
6
7
8
9

BI

BJ

BK

BL

BM

Film Fill No. of


Sheets over
Cell Length

No. Splash
Bars in Cross
Section

Integer

Integer

Wet Heat Transfer Media

Internal Cell
Lengh

Internal Cell
Width

in
Integer

in
Integer

Fill Total Gross Film Fill No. of


Face Area per
Sheets over
Cell
Cell Width

ft
Decimal

Integer

BN

BO

BP

BQ

BR

BS

1
2

Splash Bars
Pattern

Number of Heat Heat Exchanger


Splash Deck Heat Exchanger
Exchangers per Total Number of
No. of layers
Type
Cell
Plates
Heat Exchanger
Number of
plates type A

5
6
7
8
9

String

Integer

String

Decimal

Integer

Integer

BT

BU

BV

BW

BX

BY

1
2

3
Heat Exchanger Heat Exchanger
Number of
Number of
plates type B
plates type C
5
6
7
8
9

Integer

Integer

Heat Exchanger Heat Exchanger


Plate Height
Plate Width

in
Decimal

in
Decimal

Heat Exchanger Heat Exchanger


Plate Depth
Number of
Inside
Passes

in
Decimal

Integer

BZ
1
2

5
6
7
8
9

CA

CB

CC

CD

CE

Heat Exchanger
Heat Exchanger Heat Exchanger
Number of
Number of Heat Exchanger Heat Exchanger Heat Exchanger Heat Exchanger
Rows or
Tubes or
Tube Diameter
Width
Length
Surface Area
Passes
Passes

Integer

Integer

in
Decimal

in
Decimal

in
Decimal

ft
Decimal

CF

CG

CH

CI

CJ

CK

1
2

5
6
7
8
9

Heat Exchanger Heat Exchanger Heat Exchanger Heat Exchanger Heat Exchanger
Heat Exchanger
Number of Inlet Inlet Nozzle
Number of
Outlet Nozzle
Gross Free
Process Fluid
Nozzles
Size
Outlet Nozzles
Size
Area

Integer

in
Decimal

Integer

in
Decimal

ft
Decimal

String

CL

CM

1
2

5
6
7
8
9

CN

CO

CP

CQ

Water Distribution

Heat Exchanger
Pressure Drop

psi
Decimal

Water
Distribution
Type

String

Ratio of Prop
Fan Stack
Underside of
No. Inlet
Throat Area to
No. Nozzles or Nozzle Height
Connections per
Wet Heat
Orifices per Cell above Media or
Cell
Transfer Media
Heat Exchanger
Gross Face
Area
Integer

Integer

in
Integer

Decimal

CR
1
2

5
6
7
8
9

CS

CT

Geometric Data
Ratio of
Ratio of Fan Coverage Area to
Centrifugal Fan
Eliminator/Louver Area when projecting a
Wheel Housing Ratio of Air Inlet Gross
circle at 45o from fan inlet opening onto
Discharge Area Face Area to the Total
the Eliminator/Louver Face and
to Wet Heat
Gross Face Area of the
neglecting all portions of the projection
Transfer Media
Heat Transfer Media
which fall beyond the cell boundaries
Gross Face
(See Appendix F, Fig A, B, and C)
Area
Decimal

Decimal

Decimal

CU

CV

1
2

5
6
7
8
9

Attached Files

Ratio of Fan Plenum Width to Fan Plenum


Length (See Appendix F, Fig D)

Decimal

Name of ZIP data file attached to this model

String

Column Code
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
AA
AB
AC
AD
AE
AF
AG
AH
AI
AJ
AK
AL
AM
AN
AO
AP
AQ
AR
AS
AT
AU
AV

AW
AX
AY
AZ
BA
BB
BC
BD
BE

BF
BG
BH
BI
BJ
BK
BL
BM
BN
BO
BP
BQ
BR
BS
BT
BU
BV
BW
BX
BY
BZ
CA
CB
CC
CD
CE
CF
CG
CH
CI
CJ
CK
CL
CM
CN
CO
CP
CQ-CU
CV

Description to help user complete Data of Record

This section should ONLY be completed by ECC or CTI administrator. Participa

Manufacturer to input: Reference sequence value to illustrate the number of models in a product line
Manufacturer to input: Company name
Manufacturer to provide Product line name i.e XYZ

Manufacturer to input: Revision date of DOR


Manufacturer to input Cooling Tower Type: Cooling Tower, Closed Circuit Cooler, or Evaporative Condenser
Manufacturer to input Draft Type: Induced or Forced
Manufacturer to input Flow type of cooling tower: Counterflow, Crossflow, Combined, or Other
Manufacturer to input Fan Type with the following alternatives: Axial or Centrifugal
Manufacturer to input: Unit model nomenclature
Manufacturer to input: Nominal Water Flow Rate selected at nominal temperature conditions
Manufacturer to input: Nominal Temperature Conditions (Nominal Temperature Conditions for Open Circuit Cooling Tower, Clos

Manufacturer to input: Number of cells. A cell is the smallest portion of a model that is capable of independent air and water flow oper
Manufacturer to input: Number of Fans per Cell
Manufacturer to input: Number of Fan Motors per Cell
Manufacturer to input: Total Nameplate Fan Motor Power per Model
Manufacturer to input: Total Rated Fan Motor Power per Model
Manufacturer to input: Number of Pumps Per Cell
Manufacturer to input: Total Nameplate Pump Power per Model
Manufacturer to input: Total Rated Pump Power per Model
Manufacturer to input: Flow Rate of Recirculating Water
Manufacturer to input: Static Pressure at Recirculating Water Inlet
Manufacturer to input: Overall Height of Unit
Manufacturer to input: Fan Diameter
Manufacturer to input: Standard Fan Center Hub or Seal Disk Diameter. Central diameter of blocked airflow
Manufacturer to input: Fan Stack Height. This is the height of the formed cylinder
Manufacturer to input: Fan Stack Inlet Area. This area should include any eased inlet integral to the cylinder.
Manufacturer to input: Fan Stack Throat Area. This area should be the straight section of the cylinder where the fan tracks & is typical
Manufacturer to input: Fan Stack Discharge Area. This area should be at the discharge plane of the cylinder and may be equal to or g
Manufacturer to input Fan Blade Pitch Adjustment: Fixed or Adjustable
Manufacturer to input: Fan Wheel Outside Diameter. This is the outside diameter of the centrifugal fan ring, holding the fan blades in
Manufacturer to input: Fan Wheel Width. This is the outside width of the centrifugal fan.
Manufacturer to input: Fan Wheel Housing Width Dimension. This is the dimension = A as shown in STD-201 RS Appendix F
Manufacturer to input: Fan Wheel Housing Outside Dimension. This is the dimension = B as shown in STD-201 RS Appendix F
Manufacturer to input: Fan Wheel Housing Inside Dimension. This is the dimension = C as shown in STD-201 RS Appendix F
Manufacturer to input: Fan Wheel Housing Discharge Area.

Manufacturer to input Eliminator Type: Blade, Cellular or Integral


Manufacturer to input: Gross Area per Cell
Manufacturer to input: Louver Type: Blade, Cellular, or Integral

Manufacturer to input: Gross Face Area of Cell. Gross face area at the eliminator plane, used for calculating approach air speed. Not

Manufacturer to input: No.of Air Inlet Faces of the cell


Manufacturer to input: Air Inlet Height. It should be the dimension of the free opening height when looking face onto the air inlet.
Manufacturer to input: Louver Spacing. Sheet spacing for cellular louvers or vertical distance center to center between blade style lou
Manufacturer to input Fill Type: Film, Splash Bar, Splash Deck, or Other
Manufacturer to input: Fill Height

Manufacturer to input: Number of Counterflow Fill Layers


Manufacturer to input: Fill Cross Flow Air Travel
Manufacturer to input: Internal Cell Length
Manufacturer to input: Internal Cell Width
Manufacturer to input: Fill Total Gross Face Area per Cell
Manufacturer to input: Fill Number of Sheets Over Cell Width
Manufacturer to input: Fill Number of Sheets Over Cell Length
Manufacturer to input: Splash Bar Number in Cross Section
Manufacturer to input: Splash Bar Pattern
Manufacturer to input: Splash Deck Number of Layers
Manufacturer to input Type of Heat Exchanger: Coil, Plate HX, or Other
Manufacturer to input: Number of Heat Exchangers per Cell
Manufacturer to input: Number of Total Plates
Manufacturer to input: Number of Type A plates
Manufacturer to input: Number of Type B plates
Manufacturer to input: Number of Type C plates
Manufacturer to input: Plate Height Dimension
Manufacturer to input: Plate Width Dimension
Manufacturer to input: Plate Depth Inside Dimension
Manufacturer to input: Number of passes
Manufacturer to input: Number of rows
Manufacturer to input: Number of tubes
Manufacturer to input: Coil Tube diameter
Manufacturer to input: Heat Exchanger Width
Manufacturer to input: Heat Exchanger Length
Manufacturer to input: Heat Exchanger Surface Area
Manufacturer to input: Heat Exchanger Inlet Nozzle Quantity
Manufacturer to input: Heat Exchanger Inlet Nozzle Size
Manufacturer to input: Heat Exchanger Outlet Nozzle Quantity
Manufacturer to input: Heat Exchanger Outlet Nozzle Size
Manufacturer to input: Heat Exchanger Gross Face Area
Manufacturer to input: Heat Exchanger Process Fluid
Manufacturer to input: Heat exchanger Pressure Drop
Manufacturer to input Water Distribution Type: Spray, Gravity, Trough or Other
Manufacturer to input: Number of Inlet Connnections Per Cell
Manufacturer to input: Number of nozzles or orifices per cell
Manufacturer to input: Dimension from underside of nozzle to the top of the wet heat transfer media or Heat Exchanger
See STD-201 RS for more information
Manufacturer to input: Name of ZIP data file