Está en la página 1de 4

This document contains Japanese characters.

********************************************************************************
**
**
Series: AT compatible machine
**
Operating System: Windows Vista/XP/2000
**
ATLAS Translation Standard V14.0 L10 U001
**
ATLAS Super Pack V14.0 U001
**
**
-- Update Pack Description -**
********************************************************************************
This Update Pack is a patch containing fixes for all known bugs.
The following abbreviations are used in this document.
Windows
Windows Vista

Windows XP
Windows 2000
Internet Explorer
Windows Live Mail
Lotus Notes

Translation Server
ATLAS

: Microsoft(R) Windows Vista(R),


Microsoft(R) Windows(R) XP,
Microsoft(R) Windows(R) 2000
: Microsoft(R) Windows Vista(R) Ultimate,
Microsoft(R) Windows Vista(R) Enterprise,
Microsoft(R) Windows Vista(R) Business,
Microsoft(R) Windows Vista(R) Home Premium,
Microsoft(R) Windows Vista(R) Home Basic
: Microsoft(R) Windows(R) XP Professional,
Microsoft(R) Windows(R) XP Home Edition
: Microsoft(R) Windows(R) 2000 Professional
: Windows(R) Internet Explorer(R) 8,
Windows(R) Internet Explorer(R) 7,
Microsoft(R) Internet Explorer Version 6
: Windows Live(TM) Mail Version 2009
: Lotus Notes R8.5/8.0.2/8.0.1/8.0.0,
Lotus Notes R7.0 - 7.0.3,
Lotus Notes R6.5 - 6.5.6,
Lotus Notes R6.0.1 - 6.0.5,
Lotus Notes R5.0
: Accela BizLingo V3.0
: ATLAS Translation Standard V14.0

Microsoft, Windows, Windows Vista and Internet explorer are registered


trademarks of Microsoft Corporation in the United States and other countries.
Windows Live is either a registered trademark or trademark of Microsoft
Corporation in the United States and/or other countries.
IBM, the IBM logo, Lotus, Lotus Notes are registered trademarks of International
Business Machines Corporation in the United States or other countries or both.
Other company and product names are trademarks or registered trademarks of
their respective owners.
[High Risk Activity]
This Product is designed, developed and manufactured as contemplated for
general use, including without limitation, general office use, personal use,
household use, and ordinary industrial use, but is not designed, developed
and manufactured as contemplated for use accompanying fatal risks or dangers
that, unless extremely high safety is secured, could lead directly to death,
personal injury, severe physical damage or other loss (hereinafter "High
Safety Required Use"), including without limitation, nuclear reaction
control in nuclear facility, aircraft flight control, air traffic control,
mass transport control, medical life support system, missile launch control

in weapon system. You shall not use this Product without securing the
sufficient safety required for the High Safety Required Use. If you wish to
use this Product for High Safety Required Use, please consult with our sales
representatives in charge before such use.
** Before Using the Update Pack **
- Make sure to back up the system before applying the update pack, so the
system can be restored if a problem occurs.
- This update pack requires free space to perform updating.
Necessary Disk Space F18MB
Necessary RAM
Fno particular limitation
0. About the Update Pack (Please read)
(1) Information on Update Pack
- NOTE_EN.TXT --- Update pack notes
- README_EN.TXT --- Important information to read before using this product
and product-specific instructions (this manual)
- UPDATE_EN.TXT --- List of corrections, Update module list
- UPDATE.EXE
--- Correction application module
(2) Notes on Applying the Update Pack
- Apply all the correction files included with the update pack.
- This Update Pack includes ATLAS Emergency Patch TK00199. You can apply
this Update Pack to systems that TK00199 has already been applied to.
- Do not execute the update pack to the application system when any
"individual" correction programs have been applied.
Please contact the provider of the previous correction program before
executing this update pack.
- This update should be activated by a user with administrator status.
- Reinstall the update pack after reinstallation, modification, or recovery
of ATLAS.
(3) Further Information
See the attached UPDATE_EN.TXT for details of corrections made with the
Update Pack and a list of files contained in the Update Pack.
Help does not contain explanations for Internet Explorer 8. Please see
explanations for Internet Explorer 7 when you use Internet Explorer 8.
1. Conditions
This is an update module for "ATLAS Translation Standard V14.0 L10" and
"ATLAS Super Pack V14.0 L10".
2. Setup
(1) Create a new folder on the hard disk for the self-extracting file
(ex. C:\temp).

(2) Download the self-extracting file ATL14U1E.EXE to the new folder.


(3) Extract the downloaded self-extracting file ATL14U1E.EXE.
Open the new folder and double-click the file.
(4) Extraction starts, and the following files are created in the folder
"ATLASV14U001E", which is created in the new folder.
NOTE_EN.TXT --- Update Pack Notes
README_EN.TXT --- Important information to read before using this
product and product-specific instructions
(this manual)
UPDATE_EN.TXT --- list List of corrections, Update module list
UPDATE.EXE
--- Correction application module
(5) Close Internet Explorer and all other applications.
(6) Double click UPDATE.EXE, which was extracted in (4) to apply the
corrections to ATLAS.
When the Windows Vista User Account Control dialog box appears, check that
"ATLAS V14.0 L10" and "FUJITSU LIMITED" appear and click "Continue".
(7) Click "Next" and the "Update Pack Application Manual" is displayed. Click
"Next" after confirming the content.
(8) The "Ready to Install the Program" window appears. Click "Install".
(9) The correction module begins to install. When finished, "InstallShield
Wizard Complete" appears. Click the "Finish" button.
Setup is complete.
3. Points of Concern
+ Compatibility
- User Data Compatibility
There are no known adverse effects with user data.
- System Definition File Compatibility
There are no known adverse effects with the definition files.
- Other Compatibility Issues
- Applying this Update Pack adds user interface (radio buttons, check
boxes, text boxes and so on) for SSL/Socks connection settings to
[ATLAS Configure Server Connection] dialog box.
- The specification is changed to new one that ON/OFF status of [Auto
Translation] of ATLAS Tool Bar in Internet Explorer is kept with each
tab in each window. New tabs/windows are opened with the status that
[Auto Translation] is OFF.
+ After updating, you may delete files and folders created in step 4 of
"2. Setup". However, NOTE_EN.TXT, README_EN.TXT and UPDATE_EN.TXT contain
information about the update. View the contents before deleting.
+ With Lotus Notes 8.0.0/8.0.1 Standard Version, Mail Translation function
cannot be used when a HTML Mail is displayed in the preview pane. For HTML
Mails, please use Mail Translation function when they are opened.
+ With Windows Live Mail, Mail Translation function works for message bodies
only.

+ Applying this Update Pack make SSL/SOCKS V4 available in connection to


Translation Server.
- Translation Server must be Accela BizLingo V3.0 U003 or later.
- When Translation Server uses SSL connection, select [HTTPS] in
[Translation Server] in [ATLAS Configure Server Connection] dialog box in
ATLAS.
- When Translation Server connects via SOCKS Server, check [Using Proxy
Server] in [ATLAS Configure Server Connection] dialog box in ATLAS, then
check [Use Socks]. Also, [Address] and [Port] must be set in [Using Proxy
Server].
- Though applying this Update Pack changes [ATLAS Configure Server
Connection] dialog box, corresponding help and User's Guide are not
provided.
+ Users with JIS2004 based new characters in their user names cannot run
ATLAS.
+ This update pack is not compatible with the new JIS2004 characters (Windows
version-specific characters), which were added to Windows Vista.
- Use the following tips to ensure JIS2004 characters are not entered.
- When using Microsoft IME, do not use characters in the candidate list
marked as " (unicode)" (Windows version-specific characters).
- In the Microsoft IME character restriction settings ("
")
check "JIS X 0208
\ P /
\ " (Only
display JIS X 0208 characters/words as conversion candidates) to set
these characters to not be displayed.
- The following errors will occur if JIS2004 characters are used.
- These characters will not be translated correctly. JIS2004 characters
will be garbled and may appear as question marks, etc.
- Any data containing these characters cannot be correctly added to
dictionaries as dictionary entries or translation memory.
- Files containing these characters in their file path or name cannot be
opened, saved or translated.

También podría gustarte