Documentos de Académico
Documentos de Profesional
Documentos de Cultura
TABLE OF CONTENTS:
General Remarks ............................................................................................................ 1
0.0 Various ...................................................................................................................... 3
2.2 Solenoid Valves, Externally ....................................................................................... 4
4.X Air Heater.................................................................................................................. 5
6.X Control Box Components .......................................................................................... 6
7.X Air Compressor ......................................................................................................... 7
8.X CA Components........................................................................................................ 8
July 2005
Revision 1.4
MODE 45
Reefer Unit, CA-side
Page 1
of 9
General Remarks
Repair codes under Mode 45 relates to CA components only. Repairs to refrigeration unit
itself shall be performed as Mode 43.
Some of the codes listed relates to Upgrade modifications only and shall only be used by
locations involved in same. Modification codes will be blocked when all unit are complete.
For all repair jobs involving replacement of parts it is acceptable to apply the maximum
allowable time.
However, for all jobs with repair in text, the actual time consumed must apply. If the actual
time consumed should exceed the maximum allowable time, the latter shall apply.
For your guidance, repair codes with repair in text, usually refer to repair work requiring no
spare parts., trouble shooting, leak check, cleaning of components and wiring. Common to
all of these repair jobs is that they will vary in complexity and time consumption, from time
to time.
It is an important duty of the repair management, to ensure the the number of STS hours
applied against each repair job is minimized and that no conflicting STS codes are applied.
July 2005
Revision 1.4
MODE 45
Reefer Unit, CA-side
Page 2
of 9
Description
0.0
Max
Pieces
Manhours
per
piece
STS
Code
Conflicting
STS
Codes
0943
VARIOUS
45
45
2nd Box leak Check, Incl. Curtain (if 1st check Fails)
45
45
0,8
0940
0,5
0941
1,5
0943
0940, 5804
0,1
0999
5613
0613
Core Charges
45
July 2005
Revision 1.4
MODE 45
Reefer Unit, CA-side
Page 3
of 9
Description
Max
Pieces
Manhours
per
piece
STS
Code
Conflicting
STS
Codes
0,3
5225
5228
45
0,2
5228
5225
45
0,4
5240
45
0,4
5242
July 2005
Revision 1.4
MODE 45
Reefer Unit, CA-side
Page 4
of 9
Description
Max
Pieces
Manhours
per
piece
STS
Code
Conflicting
STS
Codes
0,3
5451
5471
45
Replace HATS
0,3
5471
5451
July 2005
Revision 1.4
MODE 45
Reefer Unit, CA-side
Page 5
of 9
Description
Max
Pieces
Manhours
per
piece
STS
Code
Conflicting
STS
Codes
0,2
5611
45
0,2
5612
45
0,2
5613
45
0,3
5614
45
0,1
5620
45
Replace Contactor
0,2
5631
45
0,2
5661
45
0,1
5633
45
0,2
5664
45
40
0,1
5676
July 2005
Revision 1.4
MODE 45
Reefer Unit, CA-side
0999
Page 6
of 9
Description
Max
Pieces
Manhours
per
piece
STS
Code
Conflicting
STS
Codes
7.X Compressor
45
Replace CA Compressor
2,5
5711
5721 5804
45
5,0
5721
45
0,4
5722
45
0,5
5723
45
0,9
5731
45
0,1
5741
45
0,1
5218
July 2005
Revision 1.4
MODE 45
Reefer Unit, CA-side
Page 7
of 9
Description
Max
Pieces
Manhours
per
piece
STS
Code
Conflicting
STS
Codes
5842
8.X CA Components
45
3,0
5800
45
1,5
5801
45
0,2
5802
45
5,8
5804
45
0,2
5811
0940
45
0,2
5812
45
0,5
5821
45
0,2
5822
45
Replace Membrane
2,0
5831
45
Replace O2 Sensor
0,3
5841
45
0,3
5842
45
0,3
5843
45
0,5
5845
July 2005
Revision 1.4
MODE 45
Reefer Unit, CA-side
5803
5800
5848
Page 8
of 9
Max
Pieces
Manhours
per
piece
STS
Code
Conflicting
STS
Codes
Mode
Description
45
0,2
5848
5845
45
0,1
5849
5848
General
45
0,0
9997
45
0,0
9998
45
0,0
9999
July 2005
Revision 1.4
MODE 45
Reefer Unit, CA-side
Page 9
of 9