Está en la página 1de 6

FIT-UP DIMENSIONAL INSPECTION

REPORT
Report No.: FU-

Code: LLM18-QP-04.14/FU
Rev.: 0
Date :
Total Page: 2

Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-FU-

Item: AIR COOLED COOLING CHAMBER

Drawing No.: AJ-2429-Z41-124

No.

Location

Drawing Dim.

Actual Dim.

Deviation

Tolerance

I. PLATFORM
1

L1

3697

L2

3697

L3

572

L4

572

L5

645

L6

645

L7

645

L8

588

L9

588

10

L10

588

11

L11

587

12

L12

587

13

L13

4659

14

L14

910

15

L15

2690

16

L16

643

17

L17

640

18

L18

640

19

L19

643

20

L20

1030

21

L21

437

22

L22

910

23

L23

5443

24

L24

800

25

L25

322

26

L26

910

27

L1

2000

28

L2

1000

29

L3

950

II. HANDRAIL

Page 1/6

(attached)

Result

Remarks

Code: LLM18-QP-04.14/FU
Rev.: 0
Date :
Total Page: 2

FIT-UP DIMENSIONAL INSPECTION


REPORT
Report No.: FUClient: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-FU-

Item: AIR COOLED COOLING CHAMBER

Drawing No.: AJ-2429-Z41-124

No.

Location

I. PLATFORM
30

Drawing Dim.

Actual Dim.

Deviation

Tolerance

L4

3440

31

L5

860

32

L6

860

33

L7

860

34

L8

690

35

L9

5700

36

L10

950

37

L11

950

38

L12

950

39

L13

950

40

L14

950

41

L15

690

42

L16

3440

43

L17

860

44

L18

860

45

L19

860

46

L20

950

47

L21

1100

48

L22

400

49

L23

350

Result

Note: Application standard EN ISO 13920:1996 class B.


Measurement implement: Metal tape.
LILAMA 18
Prepared

VKS
Reviewed

Reviewed

Sign:

Sign:

Name:

Name:

Date:

Date:

Page 2/6

(attached)

Remarks

FINAL DIMENSIONAL INSPECTION


REPORT
Report No.: DI-

Code: LLM18-QP-04.14/DI
Rev.: 0
Date :
Total Page: 2

Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-DI-

Item: AIR COOLED COOLING CHAMBER

Drawing No.: AJ-2429-Z41-124

No.

Location

Drawing Dim.

Actual Dim.

Deviation

Tolerance

I. PLATFORM
1

L1

3697

L2

3697

L3

572

L4

572

L5

645

L6

645

L7

645

L8

588

L9

588

10

L10

588

11

L11

587

12

L12

587

13

L13

4659

14

L14

910

15

L15

2690

16

L16

643

17

L17

640

18

L18

640

19

L19

643

20

L20

1030

21

L21

437

22

L22

910

23

L23

5443

24

L24

800

25

L25

322

26

L26

910

27

L1

2000

28

L2

1000

29

L3

950

II. HANDRAIL

Page 3/6

(attached)

Result

Remarks

Code: LLM18-QP-04.14/DI
Rev.: 0
Date :
Total Page: 2

FINAL DIMENSIONAL INSPECTION


REPORT
Report No.: DIClient: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-DI-

Item: AIR COOLED COOLING CHAMBER

Drawing No.: AJ-2429-Z41-124

No.

Location

I. PLATFORM
30

Drawing Dim.

Actual Dim.

Deviation

Tolerance

L4

3440

31

L5

860

32

L6

860

33

L7

860

34

L8

690

35

L9

5700

36

L10

950

37

L11

950

38

L12

950

39

L13

950

40

L14

950

41

L15

690

42

L16

3440

43

L17

860

44

L18

860

45

L19

860

46

L20

950

47

L21

1100

48

L22

400

49

L23

350

Result

Note: Application standard EN ISO 13920:1996 class B.


Measurement implement: Metal tape.
LILAMA 18
Prepared

VKS
Reviewed

Reviewed

Sign:

Sign:

Name:

Name:

Date:

Date:

Page 4/6

(attached)

Remarks

Code: LLM18-QP-04.14/VI

VISUAL INSPECTION RECORD

Rev: 0
Date:
Total page: 2

Record No.: VIClient: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Drawing No.: AJ-2429-Z41-124

Item: AIR COOLED COOLING CHAMBER

Test & Inspection


procedure

Item
No.
A

Acc.

Rej.

VISUAL CHECK FOR WELD


Fillet weld (leg length or throat
depth)

Acceptance criteria

Intermittent weld
a) Intermittent pitch
b) Weld length

Linear misalignment in
butt weld

Leg length and throat depth shall not be


less than design dimensions on drawing.
When not specified on drawing, throat
depth shall be minimum 0.7t. Where t:
thickness of a thinner plate at welded
plates
Intermittent pitch shall be between +/-10
mm of design values on drawing.
Weld length shall be between -5 and
+10 mm of design values on drawing.
Linear misalignment shall be not excess
10% of plate thickness at welds, but
maximum 3.0mm

Unevenness in bead surface


Depth D shall be 2 mm or less for
50mm long weld.

4
Irregularity in bead width
5

Difference in bead widths (a - b) shall be


5 mm
or less for 50 mm long weld.
a b < 3 mm

Overlap
Overlap shall be 1.5 mm. or less per 100
mm long in bead direction

6
Undercut

Depth of undercut shall be 1.0 mm or


less.

7
Crater treatment
8

Craters shall have been treated.

Pit

No pits shall exist

10

Slag inclusion

No included slag shall exist.

11

Crack

No cracks shall exist.

12

Spatter

Spatters shall be removed.


Conclusion

Accepted

Rejected

Remark

Code: LLM18-QP-04.14/VI

VISUAL INSPECTION RECORD

Rev: 0
Date:
Total page: 2

Record No.: VIClient: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Drawing No.: AJ-2429-Z41-124

Item: AIR COOLED COOLING CHAMBER

Item
No.

Test & Inspection


procedure

Acceptance criteria

VISUAL CHECK FOR SHAPE/SIZE

Contused wound, hammer


wound, irregularity, etc.

These wounds shall be ground for


inconspicuous and smooth surfaces.

Finished conditions after


removing temporary jigs used
during manufacture.

Smoothing shall reach the base


metal. Concave portions shall
be repaired

Contamination, stuck foreign


Cleaning has been done. No foreign
materials, and foreign materials
materials shall exist.
left in equipment.

Inclination, bend and deflection.

These defects shall not been visually


detected.

Matching marks:
1) Orientation marks
(00,900,1800,2700)
2) Center line mark

Marking shall be made.

Finished conditions at convex


and corner portions (for lined
products).

Finish shall be smooth (min. 2R).

Finished conditions at concave


and corner portions (for lined Finish shall be smooth (min. 5R).
products).

Corners in bolt holes mounting


strainers for water collecting
plates, lining attaching internal Parts to be lined shall have corners
parts, external surfaces of
chamfered (min. 1C).
flanges, and bolt holes in
flanges.
Conclusion
LILAMA 18
Prepared/Inspected

Sign
Name:
Date:

Inspected/Reviewed

Accepted

Acc.

Rej.

Rejected

VKS
Reviewed/Approved by

Remark

También podría gustarte