Está en la página 1de 9

A & M TECHNOLOGIES

Ref: A&M/SCL/342266/R0
16th July, 2014
M/s. SHESHASAI CHEMICALS LTD,
Visakhapatnam,
Andhra Pradesh

KIND ATTN: Mr. R.B.Sekhar


Dear Sir,
Sub: Requirement of LDO-HSD fired Thermic Fluid Heater
Thank you very much for your above said enquiry.
Based on the same, we are pleased to submit our offer for your kind perusal.
Our detailed offer for THERMOPAC Thermic Fluid Heater Model TPCM - 02 capable of
generating heat output of 2,00,000 KCal/hr, at a temperature of 280C when fired
with HSD/LDO.
We trust the above is in line with your requirement and incase of any further
clarifications, please feel free to contact us
Thanking you and assuring you of our prompt attention at all times,
Yours faithfully,
For A & M TECHNOLOGIES

(M.RAMA KRISHNA)
9848186200
Encl.:As above

## 49-54-4, B.S.Layout, Seethammadhara, Visakhapatnam - 13.


Tel :(0891)2535041 Fax: 0891:2536234 E-Mail:am_ramakrishna@rediffmail.com
For more information about Thermax,Visit us at :www.thermaxindia.com

INDEX

SCOPE OF SUPPLY ........................................................................................................


BATTERY LIMITS ...........................................................................................................
PERFORMANCE CRITERIA .............................................................................................
EXCLUSIONS .................................................................................................................

SCOPE OF SUPPLY

HEATER
One Heat exchanger consisting of two closely wound helical concentric coils
arranged to give three passes on flue gas side made out of ERW tubes
confirming to BS: 3059 Part I suitable for high temperature
One Single jacketed to enclose the heat exchanger coil dully insulated with
mineral wool and coated with color coated sheets
AUXILIARIES
One Dust protected, prewired wall mounted air cooled control panel housing a
Burner Management System, Switch gear consisting of contactors,
Overload relays, fuses/ MCB etc
One Centrifugal Thermic fluid circulating pump suitable for high temperaure
operation, directly to an electric motor, mounted on a common base frame
One Deaerator-cum-expansion tank consisting of expansion, Deaerator and buffer
vessels, gauge glass assembly and level switch. Nozzles are provided for inlet &
outlet on deaerator, for drain on buffer vessel and for overflow,air vent & top
up on expansion vessel
One Monobloc Pressure Jet spill return ON/OFF burner suitable for light
oil(HSD) with inbuilt combustion blower assembly along with motor and
high voltage spark ignition for burner light up. The blower will be mounted
with fuel oil pump

MOUNTINGS AND FITTINGS


One

Set Isolating needle valves for pressure indicating instruments.

FUEL
Oil Line
One

Fuel oil filter suitable for light oil

THERMIC FLUID
One spring loaded flow relief valve for mounting on Thermic outlet line.

INSTRUMENTS, CONTROLS AND SAFETIES


One Burner programmer with matching flame sensor
One Hooter mounted on control panel for audible safety alarm.
THERMIC FLUID
One Temperature indicator-cum- switch for burner ON-OFF cycle, on Thermic fluid
inlet of the heater
One Temperature indicator-cum-switch for high Thermic fluid temperature
alarm & interlock with burner, on Thermic fluid outlet of the heater
One Pressure gauge at Thermic fluid inlet of the heater
One Pressure gauge at Thermic fluid outlet of the heater
One Differential pressure switch connected across Thermic fluid inlet and
outlet of the heater for low flow alarm & interlock with burner
One Gauge glass on deaerator-cum-expansion tank
One Level switches for low level alarm & interlock with burner, on deaeratorcum- expansion tank
FLUE GAS
One Temperature indicator-cum-switch for high stack temperature alarm
BATTERY LIMITS
FUEL
Oil Line
Inlet/Outlet of oil filter
Inlet/Outlet of burner

THERMIC FLUID
Inlet and Outlet flanges of Thermic fluid circulating pump
Inlet and outlet flanges of headers of the heater
Inlet and outlet of flow relief valve
Inlet and outlet connections of Deaerator vessel
Inlet of expansion tank for topping up
Vent connection on expansion tank
Overflow connection on expansion tank
Drain connection on buffer vessel

AIR AND FLUE GAS


Suction of blower
Flue gas outlet flange on the heater

PERFORMANCE CRITERIA
THERMIC FLUID
Shell Heat Transfer Oil S2 for bulk oil temperature up to 300 Deg C
Diesel Oil (HSD)
Net Calorific Value Flash Point
Water Content
Kinematic Viscosity Pour Point
Sediment
Sulphur
-

10,500 Kcal/Kg
32C
0.05% Vol.(Max.)
2.5 cst @ 50C
5C
1% Wt Max.
1 % Wt Max.

ELECTRICAL
415 Volts6%, 50 Hz3%, 3 phase, 4 wire system and 240 Volts6%, 50 Hz3%, 1 phase
for control circuit
AMBIENT CONDITIONS
Ambient/Room temperature minimum 20C, Altitude maximum 600 meter above
sea level
* Note: Fuels to confirm to enclosed IS specification.

EXCLUSIONS

1. Chimney and flue gas duct between THERMOPAC and chimney.


2. Storage, Service tanks for Fuel Oil/Gas, Thermic Fluid etc. and piping
required up to THERMOPAC.
3. Thermic fluid storage tank and topping up pump.
4. All user equipment, their heat exchangers, automatic and manual valves and
temperature controllers etc.
5. All types of lagging of pipelines,
tank and insulation wherever required.

combined

deaerator-cum-expansion

6. All civil and structural work for installing the THERMOPAC.


7. CO2 for smothering and CO2 line up to our battery limits (stop valve).
8. Thermic fluid, Fuel oil/gas, water, power, compressed air, Labour, tools
and tackles, consumables etc. required for assembly, erection,
commissioning and operation of THERMOPAC.
9. All electrical wiring such as from Thermic fluid pump motor and from level switch
in deaerator-cum-expansion tank up to control panel, main supply cable to control
panel etc.
10. Any other items not specifically mentioned in our offer.

Commercial Terms & Conditions


1. OPERATING PARAMETERS:
- Model

TPCM - 02

- Heat output ( Kcal/hr)

2,00,000

- Maximum unit outlet temperature

280C

- Fuel

HSD/LDO

- Thermal Efficiency (based on NCV)

87 2 %

- Electrical supply

AC 3 phase, 415 6%,


50 Hz., 3%,4 wire system

2. PRICE SCHEDULE: Ex-Works, Pune


- Price of 1 No. of unit

Rs. 4, 49,000/-

- Packing & forwarding charges

3 % extra

- Supervision of Erection & Commissioning shall be done Free of Cost as part of


our services to the customer.
3. PRICE BASIS:
The prices mentioned above are ex-works, Pune and shall exclude the
following charges:
- Excise duty @ 12.36% extra and CST @ 2% against Form-C
- Octroi, transit Insurance and freight from our works to your site extra.
NOTE: The above mentioned taxes and levies shall be charged as per the rates
prevailing at the time of delivery.
Statutory Variation
Any additional taxes, duties and levies/imposition of new taxes, duties and levies at
the time of execution of this contract (till the time of final invoice) either due to
change in law or due to any interpretations of Tax authorities, shall be extra to
Purchasers account and shall be paid to Supplier.

4.

PAYMENT TERMS
40% advance along with the order.
Balance payment along with taxes and duties against Proforma invoice prior to
dispatch.

5.

DELIVERY PERIOD
The equipment shall be ready for delivery at our works in 9 Weeks from the
date of technically and commercially clear order with requisite advance.

6.

VALIDITY
The offer is open for acceptance for a period of 30 days from this date.

*** Note: we request you to release your purchase order on M/s. Thermax Limited,
Hyderabad