Anti-Hammering System

EG

Present the engineered solutions for the water Hammering in pipe lines if
it needed. Engineering and Design for the anti-hammering System which
required for your case is one of Our responsibilities

Summery of our costumers


** Ministry of irrigation and water resources
** Tiba Consultant
** Al-Andalus for trading and contracting
** Arab Contractors

General Technical Specifications


1-Pressurized Surge Tank :
Cylindrical shapes made of welded carbon steel St 37 with suitable volume pressurized tank with top
and bottom dished ends. The tank shall include the upper and lower dished ends as well as the
bottom inlet connection pieces and the safety valves connections at the top of upper dished end.The
vessel shall be suitable for maximum working pressure of 6 bars and shall be hydraulically tested at
10 bars.

*The pressure vessel opening:


1- No. 01 inlet drain connection
2- No. 01 side manhole with suitable cover
3- No. 02 level gauge opening
4- No. 01 air inlet opening with solenoid
5- No. 01 air outlet opening
6- No. 01 safety valve opening

*The pressure vessel connecting:


All connection shall be via approved flanged connection suitable for the rated pressure and shall be
designed per ASTM or DIN standard concerning flanged thickness, no. of bolts, nuts, washer and
dimensions.

The pressure vessel supports:


The vessel shall be equipped with suitable supports welded on the tank shell each support shall be
connected to the reinforced concerts structure with suitable size and nose of anchor bolts with

grooving material and accessories the vessel shall be suitable leveled on the concerts structure via
appropriate leveling plates-if required.

*The pressure vessel treatment:


a) Internal surface treatment:
1- Sand blasting and surface cleaning per specifications.
2- One coat of corrosion resistance epoxy
3- Two coats of non toxic and corrosion resistance epox

b) Internal surface treatment:


1- Sand blasting and surface cleaning per specifications.
2- One coat of corrosion resistance epoxy
3- Two coats of oil paint with approved color

*Equipment attached to the vessel:


1- Level Gauge
Glass type by bass local level gauge for water indicating Level indicator and switches are externally
mounted for easy maintenance
2- Pressure gauge (1 no.)
Pressure gauge to be located at the surge tank
3- Solenoid Valve (2 no.)
Air inlet and outlet servo operated 2-way solenoid valve closed with de-energized coil the air inlet
valve shall be installed on the main air supply line to the tank and shall permit air to enter the
tank the air outlet valve shall permit air to exhaust from the tank when the water level decrease to a
predetermined level
4- Isolating and Draining Valve (2 no.)
Manual operated valve suitable to be located at the position specified for tanks isolation and
drainage
5- Safety Relief Valve (1 no.)
Safety relief valve shall be installed on the top of the pressurized tank to allow air blow-out in case
of excessive high pressure inside the tank above the allowable limit

2- Air compressor:
Two air compressor for vessel to supply the surge tank
with Required compressed air the compressor shall be
equipped With the following:

Automatic stop/start control box


Air intake filter
Fixing rails include assembly of compressor and prime mover
Motor over load protection
Pressure switch with on/off push button
The air compressor shall be equipped with one air storage Tank with all
accessories and safety devices The compressor shall be capable to be
stated to the required Pressure. The compressor unit should have to be
installed as close as Possible to the surge tank location

3- Control panel unit :


Automatic control panel for operating the system, it gives starting & control
signals to the valves & stopping signals for positive and negative pressure for
protection the pump & delivery line