Está en la página 1de 3

Thanks all resolved The field PLNKN in table QMEL should be one referring to general counter which points to

operation number.
Dear All,
I need help from you gurus,
For a reporting purpose my requirement is I want to capture the THICKNESS Value (THICKNESS-MIC) from results
recording and want to show that against a material.

The thickness value is getting captured under (QAQEE(Structure)-SUMPLUS) where the inspection lot (QALS-
PRUEFLOS) and Material (QALS-SELMATNR)


Please let me know from which Table I can fetch the data of thickness value (which I am entering during Results
Recording) [ QAQEE(Structure)-SUMPLUS ].

QAMR Characteristic results during inspection processing
QASE Results table for the sample unit
QASR Sample results for inspection characteristics

If you are using MICs of
1) single result recording you will get vaue of result in QASE table against that lot number
2) summ. result recording ------------------------------------in QAMR table against that lot number.

please find below tables

Master Data QMAT Inspection type - material parameters
Master Data QMHU QM Link Between Inspection Lot and Handling Unit Item
Master Data QMTB Inspection method master record
Master Data QMTT Inspection Method Texts
Master Data QPAC Inspection catalog codes for selected sets
Master Data QPAM Inspection catalog selected sets
Master Data QPMK Inspection characteristic master
Master Data QPMT Master Inspection Characteristics Texts
Master Data QPMZ Assignment table - insp. methods/master insp. characteristic
Master Data TQ01D Authorization groups for QM master data
Master Data TQ01E Text authorization groups for QM master data
Master Data TQ21 Assignment of screens to screen groups
Master Data TQ25 QM:screen sequence for master and inspection characteristics
Inspection Plan PLKO Inspection plan Header
Inspection Plan MAPL Material Assignement
Inspection Plan PLPO Operation Details
Inspection Plan PLMK Inspection plan characteristics
Inspection Plan PLMW MAPL-Dependent Charac. Specifications (Inspection Plan)
Inspection Plan TQ03 QSS: Control for Screen Texts/TABLE NOT USED (Rel. 4.6)
Inspection Plan TQ29A Dependency tolerance key - nominal measurement
Inspection Plan TQ72 Type of share calculation
Inspection Plan TQ72T Texts for type of share calculation
Inspection Plan TQ75 QM formula parameters
Inspection Plan TQ75F Field names for QM formulas
Inspection Plan TQ75K Short text for Table TQ75F
Inspection Plan TQ75T Description of formula parameters


Let me repeat my question one more time...I have two inspection plan both inspection plan have same group name
but counter is different.

Inspection plan1 = Group GP1 & group counter 1
Inspection plan2 = Group GP1 & group counter 2

both inspection plan has four operation and each operation two MIC, but these MIC are different in both inspection
plan.

Now my requirement is how to differentiate these MIC in table? how I know that which MIC belongs to which
inspection plan? To understand my question if you need more info let me know.


I think the problem is you don't kow which fields to link to which tables to get you the proper characteristics in PLMK.

I believe if you try the following it will work.

Plan charc to plan opeartions
PLMK-PLNTY <> PLPO-PLNTY
PLMK-PLNNR <> PLPO-PLNNR
PLMK-PLNKN <> PLPO-PLNKN

Plan operations to task list of operations
PLPO-PLNTY <> PLAS-PLNTY
PLPO-PLNNR <> PLAS-PLNNR
PLPO-PLNKN <> PLAS-PLNKN

Task list of operations to Task List Header
PLAS-PLNTY <> PLKO-PLNTY
PLAS-PLNNR <> PLKO-PLNNR
PLAS-PLNAL <> PLKO-PLNAL

Fantastic boss, your answer help me lot. I applied following link.

PLKO --> PLAS --> PLMK

I'm looking for the table that links the QAMV-VORGLFNR and PLPO-PLNKN fields.
I have an Inspection Plan with multiple groups (PLKO-PLNAL), and these Groups have multiple Operations
(PLPO-VORNR). The link between the Nodes (PLPO-PLNKN) and the Node Number (QAMV-VORGLFNR) is
stored in a table. I just cannot find this table. Please help.
FIrst of all, if you are attempting to read operations for a specifc inspection lot, I will give you a golden
advise....Please do not attempt to go after PLKO, PLPO and such...Because that is master data and you will
have to equate the version fo the data that was copied in the lot...correct? Well, if you do want go after
master data, you need to look at PLAS..that will validate the operation record before you go after PLPO...
If you do need to get operations for the lot, look at AFVC...

Let me know if this works for you.
Good luck

Thanx for your feedback. AFVC is the table I was looking for. I missed it because the Group was not in the
original selection fields. I'll be using the Operation Text in the certificate I'll be printing.
http://www.benx.de/en/sap/table/QAMB-PM-and-QM-Docs-thread-1-523165.htm
ABLE & FIELDS FOR QA32
QALS and QAVP are the tables used in the transaction QA32-Change data for inspection.
Use the tables related to inspection lot
QALT QAMB QAMR QAMV QAPP QASE QASH QASR QAST QASV QAVE
Check the tables <b>QALS,QAMB,QAVE,QDPS,QMAT,QINF,QDQL,QDPS

También podría gustarte