Está en la página 1de 13

Aplinkos tyrimai, ininerija ir vadyba, 2013. Nr. 2(64), P.

29-41 ISSN 1392-1649 (print)


Environmental Research, Engineering and Management, 2013. No. 2(64), P. 29-41 ISSN 2029-2139 (online)
http://erem.ktu.lt







Generation and Quality Analysis of Greywater at Dhaka City


Shaikha Binte Abedin
1
, Zubayed Bin Rakib
2

1
Department of Civil Engineering, University of Information Technology and Science, Dhaka, Bangladesh
2
Department of Civil Engineering, Presidency University, Dhaka, Bangladesh

http://dx.doi.org/10.5755/j01.erem.64.2.3992



(received in April, 2013, accepted in June, 2013)

One of the natural resources available in nature is water; however, it is not readily available for
domestic use for millions of people across the globe. An increasing global population coupled with growing
urbanization worldwide has led to increased demands on water supply. The rapid growth of water-intensive
agriculture in developing countries and inefficient water management practices in the developed world are
contributing to a global reduction in future freshwater supplies. The world is currently in the midst of cross
roads where the unsustainable and impractical uses of water are no longer acceptable. The recycling and reuse
of water is therefore imperative in some areas, and increasingly such in the others to meet the demands for
urban, industrial and agricultural water requirements. Greywater, which can be defined as all in-building
wastewater streams with an exception of toilet wastewater, is a potential water source for urban reuse, as it
contains a few or no pathogens and 90 percent less nitrogen than blackwater. This study reveals the
generation and quality of greywater in Dhaka City. The groundwater level is depleting by 2/3 of a meter per
year in Dhaka. Thus, the recycling and reuse of water have become imperative to meet the demand for it. To
analyze the generation of greywater in Dhaka City, water use in five households has been studied and about
67% of water was found to be reusable, whereas about 17% of potable water was wasted in toilet flushing.
From the quality analysis, kitchen water was found to be polluted to some degree, and judging by its quality,
it should not be reused. Greywater must be treated before any kind of reuse as it exceeds the standards of the
acceptable quality of potable water and irrigation water.
Keywords: Bangladesh, greywater; darkwater; quality, quantity.



1. Introduction

Potable water is not abundant in nature. The
amount of water available for use on the planet is
finite (Athens and Ferguson 1996), and out of the
available water, only 3 percent is potable, 2 percent of
which is frozen in glaciers and polar ice caps, which
leaves only 1 percent as useable water (NASA 2007).
The source of potable water is surface water and
ground water- out of which surface water is often
found polluted. Thus, groundwater plays a very
significant role in the supply of water for human
activities. In most parts of the developing world, rapid
expansion of groundwater exploitation occurred
between 1970 and 1990 (UNWWAP 2003). In most
countries human populations are growing while water
availability is not. As a part of developing world,
Dhaka, the capital of Bangladesh, has experienced
large scale abstraction of groundwater to meet up the
water supply needs with its rapid growing population
(Khan and Siddique 2000). Dhaka, historically
reported as the city of migrants (Islam 1996) and an
over growing population zone, had a population of 4.9
million in 1985 (UNEP 1992), 7.8 million by 1195
(UNDP 1995), which grew to 10 million by 2001
(Akhter et al. 2009) and over 16 million by 2012 (CIA
World Factbook 2013). It is the 9th largest city of the
world. With this increased population water demand
is also increasing. In June 2009, water demand was
estimated to be 2470MLD, where the supply was
1930 MLD (Akhter et al. 2009). Supply from surface
water and ground water is 292.5 MLD (13%) and
1679 MLD (84%), respectively. Water demand in
2030 is estimated to be 4990 MLD (Source: DWASA
and IWM).
Ground water depletion has become alarming in
Dhaka City for last few years. Data suggested that in
1990 the depth to the water table in the peri-urban
areas was about 4 meters, and in the central region it
was about 15 meters. However, in 2002 the water
S. B. Abedin, Z. B. Rakib

30
level in the city center (Motijheel area) was about 50
meters below the mean sea level (DWASA). WASA
(Water Supply & Sewerage Authority) personnel also
reported that the citys groundwater level was on
average dropping about by 2/3 of a meter per year. At
this time water level in the city center is more than 60
meters below the mean sea level (Tamanna 2005). No
further extraction from the upper aquifer is viable.


Fig. 1. Ground water depletion of Dhaka City (Source: Tamanna 2005)

Now WASA is installing deep aquifer pumps to
abstract water from the second layer. Even this is
becoming difficult in many areas. It is high time that
we realized the value of fresh water availability in our
city. The recycling and reuse of water is therefore
imperative in some areas, and increasingly such in the
others to meet the demands for urban, industrial and
agricultural water requirements. The practice of water
reuse involves both reclaiming water sources that
would be otherwise released into the environment and
using them for a defined purpose (Tchobanoglous and
Angelakis 1996, Clark 1977, Dean and Lund 1981).
Common applications for reused water include: toilet
flushing, irrigation, and vehicle washing (USEPA
2004).
Reuse of wastewater can be an added source to
existing water sources, particularly, in arid/semi-arid
climatic regions. Most large-scale reuse systems are
found in Israel, South Africa, and arid areas of the
USA, where alternative sources of water are limited.
Even in regions where rainfall is sufficient, because of
its spatial and temporal variability, water scarcities are
created. For example, Florida, the USA, is not a dry
area, but has limited options for water storage, and
suffers from water shortages during dry spells. For
this reason, wastewater reuse schemes form a vital
supplement to the water resource of this region
(Vigneswaran and Sundaravadivel 2004).
Greywater is the wastewater or washwater from
bathtubs, showers, sinks, washing machines, and
dishwashers, which contains few or no pathogens and
90 percent less nitrogen than blackwater (toilet water)
(Christensen 2006, CDPH 2001). International
Plumbing Code (IPC) defines greywater in its
Appendix C, titled Greywater recycling systems as
waste discharged from lavatories, bathtubs, showers,
clothes washers, and laundry sinks (Kaduvinal et al.
2007). According to the MCA 75-5-325, greywater
refers to the wastewater that is collected separately
from a sewage flow and that does not contain
industrial chemicals, hazardous wastes, or wastewater
from toilets (Pedersen et al. 2007).
Greywater from low income homes in peri-urban
areas is, generally, not contaminated with heavy
metals and toxic chemicals found in urban
wastewater. Good house practices, such as using
small screens to capture food in kitchen basins,
exclusion of oils and fats from dishes before washing,
can lead to substantial reduction of organic pollution
of the greywater and simplify the application of low
cost treatment with good treatment results (Angelakis
et al. 1995). For instance, houses in rural areas of the
MENA region are usually simple and this makes it
possible to separate greywater from blackwater with
nominal adjustment of sewer pipes inside the house.
Greywater separated from the house is collected at a
point located in a place that is in the direction of
dominant wind so that odor from the treatment unit is
blown away from the house (Morel and Diener 2006).
A comprehensive analysis of greywater
characteristics was published by Ridderstolpe (2004)
for Swedish conditions and by Gulyas (2007) for
German conditions. Greywater characteristics in
South Africa and Kenya have been analyzed by
Carden et al. (2007), Mungai (2008), Kraft (2009),
and Raude et al. (2009). Greywater treatment and
reuse, for example, as part of ecological sanitation
concepts, is a relatively new concept which is often
considered as a more simple form of wastewater
treatment, but there is still a dearth of experience.
Most greywater treatment technologies are
consequential from conventional wastewater
treatment and were not developed specifically for
greywater treatment (Hoffmann et al. 2011). The
quantity of greywater generated depends on the
income level of the household. As a general rule: the
richer the people, the more greywater they produce.
Households without in-house water connection
produce greywater which is more concentrated than
wastewater from wealthy areas, due to the lower
water consumption and existing reuse practices
(Hoffmann et al. 2011).
For households with dry toilets such as pit
latrines, urine diversion dehydration toilets or
composting toilets, the greywater production equals
Generation and Quality Analysis of Greywater at Dhaka City

31
the total wastewater production of the household. On
the other hand, for households with flush toilets, the
greywater production is equal to the total wastewater
flow minus the amount used for toilet flushing.
Greywater constitutes approximately 50% of the total
volume of wastewater discharged for a household
(Roesner et al. 2006). Almeida et al. (1999) reported
that, 69% of in-building wastewater is discharged as
greywater and 31% as blackwater. The reuse of
greywater holds a number of advantages. Firstly, it is
continually and consistently produced onsite, meaning
a readily available and reliable source of water is
available for reuse. Secondly, greywater is produced
in sufficient quantities for reuse applications
(Vigneswaran and Sundaravadivel 2004). The reusing
greywater has been shown to increase the efficient use
of water in the home and minimizes the reliance on
municipal water, conserving potable water
(Christova-Boal et al. 1995). Greywater use in an
average household can lead to an estimated 18-29% in
water savings, according to Christova-Boal et al.
(1995).
Unlike many ecological stopgap measures,
greywater use is part of the fundamental solution to
many ecological problems. It will probably remain an
essentially unchanged feature of ecological houses in
the distant future. The use of greywater, as a
replacement of freshwater for particular uses, can save
money and increase effective water supply, especially
in regions where irrigation is needed (Asano et al.
1996). For sites with slow soil percolation or other
problems, a greywater system can partially or
completely substitute a costly, over-engineered septic
system (Art Ludwig). Health risks are often cited by
regulators as reasons for requiring high-tech
expensive systems although there are no recorded
instances of greywatertransmitted illness in the US
(Art Ludwig). However, greywater may contain
infectious organisms. A poorly designed system could
become a pathway for infecting people and, thus;
should be kept in mind when designing and using the
system (Vigneswaran and Sundaravadivel 2004;
Winward 2007).

Table 1. Water reclamation in the Middle East
Country Bahrain Cyprus Jordan Kuwait Qatar Israel UAE
Year 1991 1993 1993 1994 1994 1995 1995
Annual Water Withdrawal
(Mm
3
)
239 211 984 538 285 2000 2108
Annual Water Used (Mm
3
) 15 23 58 80 25 200 185
Reclaimed water as percentage
of total
6 11 6 15 9 10 9
(Source: Kaduvinal et al. 2007)

In the developed global community, countries
involved in active research and use of greywater reuse
systems include Japan, the USA, Germany, Canada,
the UK, Sweden and Australia (Kaduvinal et al. 2007).
Table 1 shows a list of countries where water is
reclaimed and its percentage of total water used. In
developed countries, the focus is placed on the
treatment of greywater with ecotechnological methods
(Gunther 2000). Some of the efficient wastewater and
greywater systems followed in developed countries
like Sweden, Japan, Greece, Germany, and the UK are
exemplary and can be emulated elsewhere in the
world (Kaduvinal et al. 2007).
Tokyo is one of the cities which have promoted
the reuse of wastewater and greywater more than any
other cities in the world. In one of the most
technologically advanced countries in the world,
wastewater treatment plants in Tokyo, Japan,
generated 10.8 X 10
12
liters of water in 1996 (Maeda
et al. 1996). The treated waste water is used for toilet
flushing, train washing, dilution water for night soil
(human feces), landscape irrigation and snow melting
(Maeda et al. 1996, Mori 1993). For instance, around
10% of wastewater treatment plants provide effluent
for reuse, and some 8.510
7
m
3
effluents are reused
each year following the advanced treatment (Maeda et
al. 1996).
In Kalmar, Sweden, the greywater purification
plant is designed to boost the subsurface flow of water
and biological interactions of 15 plants and
microorganisms in a triplicate riparian ecotone. The
water from the building in Kalmar, which is solely
greywater, is treated in the Wetpark and reused in
the building after purification (Gunther 1995). The
construction cost for the above mentioned greywater
purification system is about $700 per person which
also includes the cost of buffer tanks and pumps. The
calculations show that the residual nutrient content of
the water would be about 0.06 mg nitrogen per liter
and 0.02 mg phosphorus per liter, which is less than
1/10 of drinking water standards. After one year of
use in Sweden, tests have given the results of 0.007
mg nitrogen per liter which is highly efficient
(Gunther 1999).
Though the Australian authorities discouraged
greywater recycling in the early 1990s, the prevailing
drought conditions have prompted them to reconsider
greywater reuse for non-potable use. A simple valve
for diversion of laundry water for landscape irrigation
was developed and received interim approval from the
authorities (Anderson 1996).
Even though Germany does not face severe
water problems, the water conservation measures
practiced in Berlin and other parts of Germany are
commendable (Nolde 2005). Greywater reuse has
been practiced with greater interest and variable
success (Nolde 2005).
Like many countries of the Middle East and
North Africa, Yemen is facing severe water poverty.
The main water source, groundwater from wells,
S. B. Abedin, Z. B. Rakib

32
suffers from large and uncontrolled extraction and
increasing pollution from residential and agricultural
use. In addition, mosques are heavy users of potable
water as their patrons perform a cleansing ritual
before prayer. The water used for this ablution is
considered greywater and enters the sewage system,
which further strains the already scarce water supply.
This greywater from mosques is now being reused for
irrigation (Global DM 2005).
According to the EPA 2004; the States of
Arizona, California, Florida, Hawaii, Massachusetts,
New Jersey, North Carolina, Texas, Utah, and
Washington in the USA use reclaimed water for toilet
flushing fire protection, construction purposes,
landscape or aesthetic impoundments and cleaning
streets.
Many organizations in Jordan, Palestine,
Lebanon and Yemen are now aware of the potential of
greywater use in pen urban areas as a practice
centered on the women's role in managing the home
garden and improving food security for poor families,
and as a means for water demand management, and
reduction of pollution from septic tank systems.
(CSBE 2003, Haddadin 2006) Reclaimed water is
mainly used in agriculture and its proportion in
comparison to ground and surface water will be on the
rise, as the volume of municipal water flow increases
and the respective collection and treatment systems
expand and enhance. Almost all of Jordan's
wastewater is reused either in aquifer recharge or
directly in agriculture. (CSBE 2003, Faruqui and Al-
Jayyousi 2002, Mc-llwaine 2004)
Treated wastewater reuse in Jordan, a water
strained country, has been practiced as part of public
water policy. Government organizations cater for such
reuse. Irrigation projects were implemented in the
Jordan Valley using treated wastewater blended with
storm water impounded by the King Talal Dam.
While treated wastewater reuse has been formalized,
no attempts have been made to regulate through
legislation the reuse of greywater at the household
level (Faruqui and Al-Jayyousi 2002, Mc-llwaine
2004, Haddadin 2006, UNDP 2006).
Agricultural irrigation has by far been the largest
reported reuse of wastewater. About 41 percent of
recycled water in Japan, 60% in California, the USA,
and 15% in Tunisia are used for this purpose. In
developing countries, its application on land has
always been the predominant means of disposing
municipal wastewater as well as meeting irrigation
needs. In China, for example, at least 1.33 million
hectares of agricultural land are irrigated with
untreated or partially treated wastewater from cities.
In Mexico City, Mexico, more than 70 000 hectares of
cropland outside the city are irrigated with reclaimed
wastewater (Vigneswaran and Sundaravadivel 2004).
In this study, the generation and quality analysis
of greywater at Dhaka City has been investigated.
Greywater samples from five different areas of Dhaka
City were collected, and later those samples were
tested for water quality parameters. Following the
brief explanation of the methodology used, the results
section consists of descriptions of the quantity of
greywater generated from different areas on working
days and holidays, and the quality analysis of
greywater from the Azimpur area. The main objective
of this study is to quantify the amount of greywater
generated in Dhaka City and provide an overview of
its quality; and reveal the potentials of recycling and
reuse of greywater to meet the demand for urban,
industrial and agricultural water requirements.


2. Methodology

In order to estimate the water consumption of
households, five houses in five areas were selected,
where suitable environment could be received to
complete the task. The areas selected were Azimpur,
Uttara, Rampura, Monipuripara, and Goran (Figure
2). The determination of water use is done for two
categories of days- working days and holidays. Data
were taken for several days and then average values
are used for detailed analysis. Information was
obtained of water used for cloth washing, dish
washing, floor washing, hand washing, bathing,
ablution, drinking water and toilet flushing. Data was
collected by a questionnaire survey among the
members of the household. All the houses were
surveyed over a week. Though washing procedures
differed among the houses, for that specific week they
were requested to use a specific procedure for the
purpose of data collection. To determine the water
used, apart from toilet flushing, a specific bucket was
used for holding water. After washing, the person was
asked for the number of buckets of water used for
washing, and then multiplying this number with the
size (waster holding capacity) of bucket the amount of
water used was determined. To determine the water
used for toilet flushing, the members were requested
to keep the count of number of times they flushed the
flush tank, and by multiplying the size (waster
holding capacity) of the flush tank the amount of
darkwater generated was determined.
For qualitative analysis, greywater was collected
from Azimpur only. Five categories of water were
tested which include water used for cloth washing,
dish washing, floor washing, hand washing and
bathing. Samples were taken 3 times and tested in the
Environmental Engineering Laboratory of
Bangladesh University of Engineering and
Technology (BUET) for eight water quality
parameters which are-pH, Color, Turbidity, Total
Dissolved Solids (TDS), Total Suspended Solids
(TSS), Chemical Oxygen Demand (COD),
Biochemical Oxygen Demand (BOD)and Faecal
Coliform (FC).
pH is a measure of the acidity or basicity of an
aqueous solution. Pure water is said to be neutral,
with a pH close to 7.0 at 25 C (77 F). Ideally, water
has no color though ordinarily we think of water as
being blue in color. Infinitely small microscopic
particles add color to water. Colloidal suspensions
and non-colloidal organic acids as well as neutral salts
also affect the color of water. Pt-Co is an arbitrary
standard scale that has been developed for measuring
Generation and Quality Analysis of Greywater at Dhaka City

33
color intensity in water samples. When water is rated
as having a color of 5 units, it means: the color of this
water is equal in intensity to the color of distilled
water containing 5 milligrams of platinum as
potassium chloroplatinate per liter. Turbidity is the
lack of clarity in water. The term turbid is applied to
water containing suspended matter that interferes with
the passage of light through the water. Turbidity may
be caused by a wide variety of suspended substances
of various sizes ranging in size from colloidal to
coarse particles. Turbidity is measured in
Nephelometric Turbidity Units (NTU). The chemical
oxygen demand (COD) and biochemical oxygen
demand (BOD) tests are commonly used to indirectly
measure the amount of organic compounds in water.
COD values are greater than BOD values especially
when biologically resistant organic matter is present.
Total Solids is the sum of Total Dissolved Solids
(TDS) and Total Suspended Solids (TSS) is water.
Faecal Coliform (FC) is determined by counting the
number of coliform colonies formed with the aid of
M-FC agar and the incubator and is expressed in
CFU/100 ml. In pure drinking water, there should not
be any presence of FC. Table 2 summarizes the
methods and equipment used for determination of
those water quality parameters.
Although greywater has much lower oxygen
demand than blackwater as it contains 90% less
nitrogen than blackwater, but still it should be treated
before any kind of reuse. Precautions must be taken in
order to avoid accidental connections between
freshwater and greywater plumbing. Untreated
greywater should not be applied onto lawns, or fruit
and vegetables that are eaten raw. Although greywater
has much lower oxygen demand than blackwater as it
contains 90% less nitrogen than blackwater, but still it
should be treated before any kind of reuse.
Precautions must be taken in order to avoid accidental
connections between freshwater and greywater
plumbing. Untreated greywater should not be applied
onto lawns, or fruit and vegetables that are eaten raw.
Greywater should be used within 24 hours before
bacteria multiply. The following are the requirements
of greywater parameters that must be met in the
agricultural sector.


Fig. 2. Map showing selected areas (circled) of Dhaka City for determination of water use

S. B. Abedin, Z. B. Rakib

34

Table 2. Parameters tested
Parameter Method Equipment
pH USEPA 150.1;SM 4500-H
+
B WTW Glass Probes and HACH HQ10 pH Meter
Color USEPA 110.2;SM 2120 C DR4000 UV Spectrophotometer
Turbidity USEPA 180.1 Rev 2;SM 2130 B HACH Portable Turbidimeter
TDS USEPA 160.2;SM 2540 B-D Oven
TSS USEPA 160.2;SM 2540 D Oven
BOD USEPA 405.1;SM 5210 B;SM 5210 D Winkler Bottle and OxiTop Control
COD USEPA 410.4;SM 5220 D DR4000 UV Spectrophotometer
FC SM 9200G Vacuum pump and Incubator

For the purpose of successful implementation of
greywater recycling different countries of the world
have already started the quantification and
characterization of greywater. In most countries
guidelines and standards either do not exist or are
being revised or expanded. Guideline values of
greywater parameters for agricultural sector and
potable water are listed in Table 3 and the available
criteria for toilet flushing and domestic water
recycling are shown in Table 4.

Table 3. Guideline values of greywater parameters for agricultural sector and potable water
Parameters
Agricultural Sector Potable Water
Maximum Permitted
Values
Bangladesh Standard
(ECR,1997)
WHO Guideline
Values,2004
pH 6.5-8.5 6.5-8.5 6.5-8.5
BOD
5
,
20C
(mg/l) 120 0.2 -
COD (mg/l) 200 4 -
TSS (mg/l) 120 10 -
TDS (mg/l) 13400 1000 1000
b
Color (Pt-Co unit) - 15 15
c
Turbidity (NTU) - 10 5
c

FC (MPN/100ml) 1000 0 0
c= consumer acceptability consideration; b= taste threshold/consideration (Source: M.Platzer et al. 2004)

For the purpose of successful implementation of
greywater recycling different countries of the world
have already started the quantification and
characterization of greywater. In most countries
guidelines and standards either do not exist or are
being revised or expanded. Guideline values of
greywater parameters for agricultural sector and
potable water are listed in table 3 and the available
criteria for toilet flushing and domestic water
recycling are available which are shown in table 4.

Table 4. Guidelines and standards for water reuse for toilet flushing and domestic water recycling
Parameter

Toilet Flushing Domestic Water Recycling
US Japan WHO USEPA
USA,
NSF
Australia UK Germany
pH 6.0-9.0 5.8-8.6

6.0-9.0

6.0-9.0
BOD
5
(mg/l) 10

10

20

20
Turbidity (NTU) 2

5

2

1.0-2.0
TC (no./100ml)

1000(m), 200(g) <10

<1 ND 100
FC (no./100ml) ND 10

<10 <240 <4

10
ND= not detectable; (m) =mandatory, (g) = guideline (Source: Tamanna 2005)

3. Results and Discussion

3.1. Quantification of Greywater Generation

From the data in Table 5 it is apparent that, the
per capita consumption of water of middle class
families in Dhaka City varies from about 200 to 300
liters per day, with an average of approximately 252
liters per capita per day. From the last row of the
Table it is quite clear that per capita water
consumption differs from area to area. Water is fairly
available in Rampura due to the current Mahanagar
project, for which the water consumption (323 liters
per capita per day) is comparably higher for this area
than the others. Whereas, in Goran the consumption is
the lowest (224 liters per capita per day) as water-
supply is not available throughout the day.Uttara,
being a more planned part of the city, has a fairly well
supply of water, which is comprehensible from the
water use data. From Table 5 it is also understandable
that water consumption on weekdays is less than
water consumption on holidays, owing to the fact that
people spend more time at home in holidays than on
weekdays.

Generation and Quality Analysis of Greywater at Dhaka City

35

Table 5. Water consumption
Area
Water consumption on Holidays (Liter/day) Water consumption on Weekdays (Liter/day)
Rampura Uttara Azimpur Monipuripara Goran Rampura Uttara Azimpur Monipuripara Goran
Family Member 4 4 3 4 5 4 4 3 4 5
Bathing 350 250 220 250 300 325 200 200 250 280
Cloth washing 250 250 150 210 200 240 250 150 210 180
Drinking Water 8 7.5 9 7.5 9 7 6 7.5 6 8
Dish washing 300 200 90 140 180 200 150 70 100 150
Hand washing 65 70 40 30 30 40 50 40 30 30
Ablution 120 80 30 40 70 80 50 30 30 45
Floor washing 50 200 50 90 80 50 200 50 90 80
Toilet Flushing 150 150 170 210 250 90 120 150 190 210
Consumption(lpcd) 323 302 253 244 224 258 257 233 227 197
lpcd: liter per capita per day

Table 6. Average water consumption (in percentage)
Type of Water
Average Holiday Water
consumption (%)
Average Weekday Water
consumption (%)
Average Water
consumption (%)
Bathing 25.8 27.1 26.5
Cloth washing 19.8 22.1 21.0
Drinking Water 0.8 0.8 0.8
Dishwashing 16.4 14.1 15.2
Hand washing 4.4 4.2 4.3
Ablution 6.0 5.0 5.5
Floor washing 8.7 9.9 9.3
Flush 18.0 16.9 17.5
Generation of greywater (considering kitchen water as greywater): 82.50 %
Generation of greywater (considering kitchen water as darkwater): 67.30 %


Table 7. Average water consumption for different areas (from DWASA-Water bill)
Uttara area, 2011 Monipuripara area, 2011 Goran area, 2011
Total people living in the
building = 62
Total people living in the
building = 183
No of people living in the building =
20
Month
Consumption
(liter)
Month
Consumption
(liter)
Month
Consumption
(liter)
January 545000 January 1208000 January 92000
February 535000 February 1795000 February 80000
March 537000 March 1680000 March 99000
April 535000 April 1913000 April 101000
May 539000 May 2039000 May 103000
June 1425000 June 1967000 June 150000
July 698000 July 2021000 July 212000
August 782000 August 2119000 August 208000
September 658000 September 1931000 September 186000
October 705000 October 2611000 October 175000
November 678000 November 1933000 November 102000
December 675000 December 1813000 December 72000
Consumption (lpcd) 367.3 liter Consumption (lpcd) 345 liter Consumption (lpcd) 216.4 liter
lpcd: liter per capita per day

Table 6 shows the average water consumption of
both holidays and weekdays in a percentage form.
The Table indicates that the majority of water use in
household is for bathing and cloth washing. Dish
washing and toilet flushing account for the next major
use of household water. It is important to note that
almost 17-18 % of potable water is used for toilet
flushing which can be saved by reusing greywater,
which could result in saving nearly 45 liters per capita
per day of potable water (considering average water
use of approximately 250 liters per capita per day).
Looking at the Table it can be said that about 82%
(200 liters per capita per day) of potable water
(including kitchen water) can be reused as greywater.
Excluding kitchen water (as it is exceedingly
polluted), about 67% of the generated water is
greywater, that is about 170 liters per capita per day.
Roesner et al. (2006) observed 50% of the total
volume of wastewater discharged for a household to
be greywater, whereas Almeida et al. (1999) reported
S. B. Abedin, Z. B. Rakib

36
that, 69% of in-building wastewater is discharged as
greywater, which is very similar to the results (67%)
of the current study. This huge quantity of water can
be diverted from the sewage water system and reused
after basic treatments. Greywater quantities of 0.5-1
liter of water per hand washing event, 40 liters water
having a 5-minute shower and 5-25 liters water for
preparing a three-course meal and dish washing were
measured at sustainable sanitation projects in Peru
and Brazil by Hoffmann et al. (2011).
Table 7 displays the average water consumption
of three of the selected areas in Dhaka City obtained
from the monthly water bills of DWASA (Dhaka
Water Supply and Sewerage Authority). It is seen
from the Table that the amount of water use (liter per
capita per day) obtained from the survey does not
coincide with the values reported by DWASA.
Particularly, there is a huge gap (nearly 30%) for
Monipuripara area. While water use from the survey
of Uttara and Monipuripara areas is found to be lower
than the value reported by DWASA, the opposite is
found for Goran area. This gives an indication that a
lot of water is lost due to leakages, misuses, faulty
connections and faucets.

3.2. Analysis of the Quality of Greywater

Table 8 summarizes test results of the eight
water quality parameters, pH, Color, Turbidity, TDS,
TSS, COD, BOD
5
and FC of the greywater samples.
From this analysis we can see that pH of
greywater has the range of 6.451.05, kitchen water
being the most acidic. The average pH value of
kitchen water is 5.804, which is fairly acidic due to
the presence of organic acids produced by edible
organic compounds. Cloth washing water has an
average pH of 7.401, with a value of 7.469, and it
shows very little deviation from the average. It is
slightly basic due to the use of soaps and detergents
for cloth washing purposes. Water from floor wash,
bath and basin is all slightly acidic (average pH 6.2-
6.7). pH value of 6.6-8.7 in a greywater study for
Brisbane was reported by Jeppesen (1996) and
Christova-Boal et al. (1995) reported pH value of 6.4-
8.1 and 6.3-9.5 for bath water and cloth wash,
respectively, (CSBE 2003) which is in congruence
with our test results. The standard pH range of potable
water irrigation water is 6.5-8.5 according to the
Bangladesh Standard (ECR 1997) and WHO
Guideline Value (2004). Elimination of the kitchen
water makes the average value of pH of greywater to
be 6.70; which makes it suitable for reuse.
The true color has been measured by filtering the
water sample. The highest color came from kitchen
water (516.7Pt-Co), as it contains much more organic
matters derived from food. The lowest color was
obtained for floor wash, although the value (262 Pt-
Co) is quite high from the standard point of view. The
color of floor wash could be due to the presence of
dissolved salts. The color of the water from cloth
washing is due to the dye of clothes and dissolved
salts from detergent. The color of bath water and hand
wash could be from soap and dissolved salts. The
average value of color of greywater is 395 Pt-Co,
having a range of 355185 Pt-Co which is fairly high.
Greywater is high in turbidity as it contains lots
of suspended particles resulting from washing
activities. The analysis shows that turbidity is the
highest for water of cloth washing and the lowest for
basin water, the standard value of turbidity according
to the Bangladesh Standard (ECR 1997) and the
WHO guideline value (2004) being 10NTU and
5NTU, respectively. The range of turbidity of
greywater is 241177 NTU. Comparing with these
standard values we can see that greywater has high
turbidity and should be treated before reuse. Turbidity
of the water of floor wash displays a high degree of
variation, whereas the other four categories show less
deviation. Khong (2009) reported turbidity values of
84.8 mg/l and 164 mg/l for bath and hand basin,
respectively (Jefferson et al. 2004), which are
analogous to the values obtained from our test
samples. Suspended solids (dirt, lint), organic
material, oil and grease, sodium, nitrates and
phosphates (from detergent) have increased salinity,
while pH and bleach are the probable sources of
turbidity of greywater from cloth wash (CSBE 2003).
Bacteria, hair, organic material and suspended solids
(skin, particles, lint), oil and grease, soap and
detergent residue usually result in turbidity of
greywater obtained from bath water and basin water
(CSBE 2003).
Greywater has a high range of COD values (600-
2500 mg/l). Kitchen water has the highest average
COD value 1846.3 mg/l, whereas basin water has the
lowest (672 mg/l). Water from floor wash and kitchen
displays a high degree of variation. Both these
categories, particularly, kitchen water, bear a high
COD value due to the presence of organic compounds
from human uses. Khong (2009) testified COD values
of 420 mg/l and 587 mg/l for bath and hand basin,
respectively (Jefferson et al. 2004), which are slightly
lower than the values obtained from our test samples.
The Bangladesh standard (ECR 1997) of COD for
potable water is 4 mg/l and that for agricultural use is
200mg/l. From the data; it can be said that it is not
wise to reuse the kitchen water. Greywater from other
sources also requires treatment before reuse.
The standard of BOD
5
for wastewater discharge
to the irrigated land is 100 mg/l (Bangladesh
Environmental Conservation Rules 1997, schedule-
10). But, as we can see BOD
5
of greywater has a
much higher value, it needs to be treated before any
kind of reuse. Greywater from kitchen water can have
a very high organic load from food scraps, oil and
grease which can result in a high concentration of
organic matter of more than 500 mg BOD/L
(Hoffmann et al 2011). Apart from cloth washing
water, BOD
5
of the rest of greywater is in the range of
300-400 mg/l. The kitchen water has the highest value
of BOD
5
due to organic matter from food. It is very
interesting to note that average COD of cloth washing
water is 1253.3 mg/l, but the average BOD
5
value is
only 73.7 mg/l; which indicates that a lot of
biodegradable organic matters are present. Water
from floor wash and cloth wash shows a high amount
Generation and Quality Analysis of Greywater at Dhaka City

37
of disparity. BOD
5
of 90-120 mg/l was affirmed by
Jeppesen (1996) for greywater study in Brisbane and
Christova-Boal et al. (1995) reported BOD
5
of 45-330
mg/l and 10-520 mg/l for bath water and cloth wash,
respectively (CSBE 2003). Results of bath water from
previous studies are analogous to our test results, but
cloth wash has revealed comparatively lower BOD
5

values. Khong (2009) quantified BOD values of 146
mg/l and 155 mg/l for bath and basin water,
respectively (Jefferson et al. 2004), which are
considerably lower than the values obtained from our
test samples.
For TDS, we can see that cloth wash has the
highest average value (1120.3 mg/l) as there are
detergents dissolved in it along with dissolved salts.
Basin water has a fairly low TDS value. TDS of
greywater from floor wash, kitchen and bath falls in
the range 450-650 mg/l. The standard of TDS for
irrigation water is 1180 (mg/l). As it is seen that TDS
of all the samples is below this maximum range,
greywater can be considered to be suitable enough for
agricultural use without any treatment.


Table 8. Results of test of quality parameters
Parameter Sample no Floor Wash Cloth Wash Kitchen Water Bath water Basin Water
pH
1 6.842 7.412 5.425 6.001 6.232
2 6.57 7.469 5.813 6.321 6.343
3 6.726 7.321 6.175 6.531 6.823
Average 6.713 7.401 5.804 6.284 6.466
Color (Pt-Co)
1 169 254 540 450 410
2 337 360 520 520 490
3 280 320 490 460 320
Average 262 311.3 516.7 476.7 406.7
Turbidity (NTU)
1 418 410 303 74 65
2 247 391 345 90.5 85.2
3 354 386 312 102 95
Average 339.7 395.7 320 88.8 81.7
COD (mg/l)
1 579 1056 1104 560 654
2 614 1105 2510 804 754
3 1473 1599 1925 706 608
Average 888.6 1253.3 1846.3 690 672
BOD
5
(mg/l)
1 640 86 600 320 300
2 176 25 600 420 380
3 320 110 560 360 320
Average 378.6 73.7 586.7 366.7 333.3
TDS (mg/l)
1 455 832 654 432 155
2 775 1573 684 532 215
3 661 956 615 445 118
Average 630.3 1120.3 651 469.7 162.7
TSS (mg/l)
1 448 875 1235 74 62
2 751 1574 2414 83 54
3 820 1160 1925 79 59
Average 673 1203 1858 78.7 58.3
FC (CFU/100
ml)
1 TNTC 1600 TNTC 900 400
2 45000 1400 287000 700 500
3 40000 1200 165000 600 400
Average 42500 1400 226000 733.3 433.3
TNTC= Too Numerous to Count

Total suspended solid, TSS, is higher in kitchen
water because wash water from food, vegetables, fish,
etc. is added to it. Greywater from kitchen sinks can
have a high amount of sand from washing of
vegetables. Furthermore, the use of ash for
dishwashing can cause a high value of suspended
particles (Hoffmann et al 2011). Except the basin
water, all types of greywater cross the limit of the
NATA standard 67 mg/l. Water from floor wash,
cloth wash and kitchen has a very high degree of
variation. Bath water and basin water have fairly low
amounts of TSS. Christova-Boal et al. (1995) reported
pH value of 43-380 mg/l and 10-520 mg/l for bath
water and cloth wash, respectively (CSBE 2003).
Outcomes from our tests indicate similar values for
bath water (74-83 mg/l), but higher average values for
cloth wash (875-1574 mg/l).
Kitchen water and floor wash have a high
number of Fecal Coliform (FC). While testing with a
dilution factor of 100, FC of kitchen water and floor
wash were too many to count. A study for greywater
in Arizona has revealed FC of 20-7,640,000 CFU/100
ml (CSBE 2003), which is in congruence with the
results of kitchen water and floor wash of our study.
The other categories of greywater also have a high
number of FC. This concludes that greywater should
be treated for FC before reuse.
Figure 3 shows the contrast of the greywater
quality parameters; (a), (b) and (c) display the average
S. B. Abedin, Z. B. Rakib

38
value of parameters of the samples tested and (d)
illustrates the pH of individual samples.





Fig. 3. Comparison of quality parameters of greywater (a) average BOD-COD (b) average TDS-TSS (c) average
Turbidity-Color (d) pH

4. Conclusions

This study has mainly highlighted the generation
and quality assessment of greywater from different
locations in Dhaka City. The average water
consumption for the middle class families is 200-300
liters per capita per day. The bulk of water in
household is used for bathing and cloth washing. Dish
washing and toilet flushing account for subsequent
major uses of household water. Almost 17-18 % of
potable water is used for toilet flushing which can be
saved by reusing greywater. Excluding kitchen water,
about 67% of the generated water is greywater (i.e.
about 170 liters per capita per day) which could be
reused after treatment. The values of the tested eight
parameters (i.e. pH, Color, Turbidity, BOD, COD,
TDS, TSS, FC) of the generated greywater exceeded
the standard permissible values of water quality.
Kitchen water was found to be the most polluted,
which indicates its non-reusability. After exclusion of
kitchen water, greywater has average pH 6-7.5, color
170-520 Pt-Co, turbidity 65-420 NTU, TDS 120-1570
mg/l, TSS 55-1575 mg/l, BOD 12-320 mg/l, COD
5801600 mg/l, Fecal coliform 400-42500
CFU/100ml, which exceeds the maximum permissible
range of standard quality of irrigation water and
potable water. Kitchen wastes are high in suspended
solids, fats, oils, and grease, and their generally high
organic content encourages the growth of bacteria.
Also, high fat and solid content cause problems for
filtration and pumping. Due to contamination by oils,
greases, and food particles, and its low contribution to
the total waste stream for a household, kitchen water
is not recommended as a source of greywater. A
number of key issues of concern need to be taken into
attention when intending the reuse of greywater. The
system should be as simple and easy to use and
maintain as possible, while reducing risk to human
health. If storage is required, the greywater must be
treated to eliminate biodegradable contaminants;
otherwise the greywater will quickly become septic
and may generate toxic odors and create other
aesthetic and operational problems. Stresses on water
resources for household, commercial, industrial and
agricultural purposes are greatly increasing. Given the
hasty spread of water pollution and the growing
concern about water availability, the links between
quantity and quality of water supplies have become
more apparent. Ground water depletion has become
alarming in Dhaka City for the last few years, and in
many areas there is already a widespread scarcity and
increased pollution of freshwater resources. The
recycling and reuse of greywater are therefore
imperative in those and other areas to meet the
demand for urban, industrial and agricultural water
requirements. Reuse of greywater can be a
supplementary source to the existing water sources.
Results of this study can lay the foundation for
development of greywater reuse and recycling and,
thus; reduce the stress on water resources in Dhaka
City.

.
Generation and Quality Analysis of Greywater at Dhaka City

39
5. Recommendations

Some scopes of the study that can follow the
present assessment are quality analysis from the zones
of Dhaka City other than the ones present in this
study. Quality analysis after treatment may be a
significant extension of the work which might later
lead to the selection of suitable treatments required
for reusing greywater. Survey can be done to find out
the possible level of public acceptance of greywater
reuse.


Acknowledgements

Authors are grateful to the lab assistants at the
Environmental Engineering Laboratory of
Bangladesh University of Engineering and
Technology (BUET) for their assistance during the
testing of quality parameters. They also express
gratitude towards the families that helped conduct the
survey for quantification of greywater generation.


References

Akhter, H., Ahmed, M.S., Rasheed, K.B.S. 2009.
Spatial and Temporal Analysis of Groundwater Level
Fluctuation in Dhaka City, Bangladesh, Asian Journal of
Earth Sciences 2 (2): 49-57,2009 ISSN 1819-1886.
Almeida, M.C., Butler, D., Friedler, E. 1999. At-
source domestic wastewater quality. Urban Water, 1, pp:
49-55.
http://dx.doi.org/10.1016/S1462-0758(99)00008-4
Anderson, M. J. 1996. Current water recycling
initiatives in Australia: Scenarios for the 21st century.
Water Science and Technology, 33(11), 37-43.
http://dx.doi.org/10.1016/0273-1223(96)00404-0
Angelakis, A., Asano, T., Diamadopoulos, E., And
Tchobanoglous, G. 1995. Wastewater reclamation and
reuse. Selected Proceedings of the International Association
for Water Quality 2nd International symposium on
wastewater reclamation and reuse, Iraklio, Crete, Greece,
1720 October, 492 pp.
Art Ludwig, The New Create an Oasis with
Greywater: Choosing, Building and Using Greywater
Systems -Includes Branched Drains, Revised and Expanded
5
th
Edition,
[http://www.oasisdesign.net/greywater/createanoasis/]
Asano, T., Maeda, M., Takaki, M. 1996. Wastewater
reclamation and reuse in Japan: overview and
implementation examples. Water Science Technology,
34(11), 319-226,
http://dx.doi.org/10.1016/S0273-1223(96)00841-4
Athens, L., And Ferguson, B. K. 1996. "Water
issues." In: Sustainable Building Technical Manual, Public
technology, Inc., Portland, OR, 52-64.
BC Green Building Code Background Research,
Greywater Recycling, October 2007.
Capital Regional District. "Greywater Reuse Study
Report." November 1, 2004.
[http://www.crd.bc.ca/reports/water_/2004_/crdgreywaterre
usestu/CRDGreywaterReuseStudyFinalReport.pdf]
Carden, K., Armitage, N., Winter, K., Sichone, O. &
Rivett, U. 2007. Understanding the use and disposal of
greywater in the non-sewered areas in South Africa. Report
to the Water Research Commission WRC Report No
1524/1/07, South Africa.
Cdph, California Department of Public Health. 2001.
California Health Laws Related to Recycled Water. The
Purple Book. Excerpts from the Health and Safety Code,
Water Code, and Titles 22 and 17 from the California Code
of Regulations.
Center for the Study of the Built Environment
(CSBE). 2003. Greywater Reuse in Other Countries and its
Applicability to Jordan. Funded by the Ministry of
Planning, Kingdom of Jordan.
[http://www.csbe.org/graywater/report/report_final.pdf]
Christensen, B. 2006. A sourcebook for green and
sustainable building. (December 5, 2006).
[http://www.greenbuilder.com/sourcebook/]
Christova-Boal, D., Eden, R. E. & Mcfarlane, S. 1996.
An investigation into greywater reuse for urban residential
properties. Desal, 106(1-3), 391-7.
Christova-Boal, D., Lechte, P., &Shipton, R. 1995.
Installation and Evaluation of Domestic Graywater Systems.
Executive Summary. Department of Civil and Building
Engineering. Victoria University of Technology, Victoria,
Australia. Retrieved February 15, 2009.
CIA World Factbook. 2013.
https://www.cia.gov/library/publications/the-world-
factbook/fields/2119.html (Online: accessed 05th May
2013).
Clark, J. W., Viessman, Jr. W., & Hammer, M. J.
1977. Water Supply and Pollution Control. New York:
Harper and Row publishers. ISBN 0-7002-2495-5, 857 pp.
CSBE, Center for the Study of the Built Environment.
2003. Graywater Reuse in Other Countries and its
Applicability to Jordan. Funded by the Ministry of
Planning, Kingdom of Jordan.
[http://www.csbe.org/graywater/report/report_final.pdf]
Dean, R. And Lund, E. 1981. Water Reuse
Problems and Solutions. New York: Academic Press,
264pp.
DWASA, Dhaka Water Supply and Sewerage
Authority [http://www.dwasa.org.bd/] [Online: accessed
05th March 2013]
EPA. 2004. Guidelines for Water Reuse. U.S.
Environmental Protection Agency. Washington DC.
Faruqui, N. And Al-Jayyousi, 0. 2002. Greywater
Reuse in Urban Agriculture for Poverty Alleviation: A
Case-Study in Jordan. Water International, 27-3.
GLOBAL DM 2005: Livelihoods in a Sustainable
Environment, Department of Environmental Affairs,
Ministry of Water and Environment, Yemen.
[http://wbi.worldbank.org/developmentmarketplace/idea/reu
sing-mosque-water-irrigation-yemen]
Greywater Recycling Basics,
[http://www.letsgogreen.com/greywater-recycling.html]
[Online: accessed 27th October 2011]
Gulyas, H. 2007. Greywater reuse Concepts,
benefits, risks and treatment technologies. International
Conference on Sustainable Sanitation Food and Water
Security for Latin America, Fortaleza, Cear, Brazil.
Gunther, F. 1999. "Wastewater treatment by
greywater separation: Outline for a biologically based
greywater purification plant in Sweden." Ecological
Engineering, 15, 139-156.
http://dx.doi.org/10.1016/S0925-8574(99)00040-3
Gunther, F. 2000. Wastewater treatment by greywater
separation: outline for a biologically based greywater plant
in Sweden, Ecological Engineering. 15: 136-14
http://dx.doi.org/10.1016/S0925-8574(99)00040-3
Gunther, F. Wetparks: Not a new way to purify water
[http://www.holon.se/folke/projects/vatpark/concept.shtml]
[Online: accessed 27th June 2012]
S. B. Abedin, Z. B. Rakib

40
Gunther, F., 1995."Wastewater treatment by source
separation: biologically based greywater purification"
(http://www.holon.se/folke/projects/vatpark/Kth/guntha.sht
ml#Outline) (April 30, 2007).
Haddadin, Munther J. (ed). 2006. Water Resources in
Jordan: Evolving Policies for Development, the
Environment and Conflict Resolution, REF Press,
Washington DC, Chapter I.
PMCid:3167077
Hoffmann, H., Platzer, C., Winker, M., Muench, E
Von. 2011. Technology review of constructed wetlands
Subsurface flow constructed wetlands for greywater and
domestic wastewater treatment, Deutsche Gesellschaft fr,
Internationale Zusammenarbeit (GIZ) GmbH, Sustainable
sanitation - ecosan program, Postfach 5180, 65726
Eschborn, Germany.
Islam, N. 1996. Dhaka: From City to Mega City.
Dhaka: Urban Studies Program.
Jefferson, B., Palmer, A., Jeffrey, P., Stuetz, R., Judd,
S. 2004. Grey water characterisation and its impact on the
selection and operation of technologies for urban reuse,
Water Science & Technology Vol 50 No 2 pp 157164.
PMid:15344786
Jeppesen, B. 1996. Domestic greywater re -use:
Australia's challenge for the future. Desal, 106(1-3), 311-5.
KADUVINAL, J. 2007. Effects of the implementation
of greywater reuse systems on construction cost and project
schedule, Texas A & M University.
Khan, H. And Siddique, Q. 2000. Urban water
management problems in developing countries with
particular reference to Bangladesh. Water Resources
Development 16(1).
Khong, Chung M. 2009. Perception and use of
graywater in Berkeley, California. Master's Theses. San
Jose State University, Paper 3693.
Kraft, L. 2009. Characterisation of greywater from
peri-urban areas in Nakuru, Kenya. Diploma thesis,
University of Applied Sciences Weihenstefan, Germany
(Fachhochschule Weihenstephan Abteilung Triesdorf).
Maeda, M., Nakada, K., Kawamoto, K., And Ikeda,
M. 1996. "Area wide reuse of reclaimed water in Tokyo,
Japan." Water Science and Technology, 33(11), 51-57.
http://dx.doi.org/10.1016/0273-1223(96)00406-4
Mc-Llwaine S. 2004. Reusing Domestic Greywater as
a Method of Water Demand Reduction in Jordan. Paper
presented in Water Demand Management Conference at the
Dead Sea, 2004.
Morel, A. And Diener, S. 2006. Greywater
Management in Low and Middle Income Countries. Review
of Different Treatment Systems for Households or
Neighborhoods.
Mori, A. 1993. Treatment and Recycling of Sewage
Sludge in Yokohama, Proceedings of the 15th Federal
Convention of Australian Water and Wastewater
Association, 1823 April, 1993, p 682-688.
Mungai, G. 2008. Impacts of long-term greywater
disposal on soil properties and reuse in urban agriculture in
an informal settlement - a case study of Waruku, Nairobi.
MSc thesis MWI 2008/10, UNESCO-IHE Institute for
Water Education, Delft, The Netherlands.
National Aeronautics and Space Administration
(NASA). 2007. "The water cycle."
[http://neptune.gsfc.gov/education/watercycle.php] (Online:
accessed February 23, 2007).
Nolde, E. 2005. Greywater recycling systems in
Germany-results, experiences and guidelines. Water Science
and Technology, 51(10), 275-284.
Oasis Design. "Greywater Policy Packet." 2005.
[http://www.oasisdesign.net/downloads/GWPolicyPacket.pd
f]
Pedersen, A., Woelfe-Erskine, C., And Hill-Hart, J.
2007. Gray Water Policy Proposal, University of Montana-
Environmental Studies Program.
[http://greywateraction.org/content/policy-
recommendations-montana]
Platzer, M., Cceres, V., Fong, N. 2004. The reuse of
treated wastewater for agricultural purposes in Nicaragua;
Central America. Water Science and Technology, 50(2),
293-300.
PMid:15344804
Raude, J., Mutua, B., Chemelil, M. & Sleytr, K. 2009.
Characterisation of urban and peri-urban greywater of
Nakuru municipality, Kenya. 34th WEDC conference in
Addis Ababa, Ethiopia.
PMCid:3167643
Ridderstolpe, P. 2004. Introduction to greywater
management, Stockholm Environment Institute, Sweden,
Report 2004-4.
Roesner, L., Qian, Y., Criswell, M., Stromberger, M.,
& Klein, S. 2006. Long Term Effects of Landscape
Irrigation Using Household GraywaterLiterature Review
and Synthesis. The Water Environment Research
Foundation and the Soap and Detergent Association.
Retrieved February 15, 2009.
Tamanna, M. 2011. Greywater Generation and
Quality Measurement at a Specific Site in Dhaka City,
Undergraduate thesis, Bangladesh University of
Engineering and Technology.
Tchobanoglous, G., Angelakis, A. N. 1996.
Technologies for wastewater treatment appropriate for
reuse: Potential for applications in Greece. Water Science
and Technology, 33(1011), 1727.
UNDP (United Nations Development Programme).
1995. Human Development Report 1995: Gender and
Human Development Technical Report. UNDP, New York.
UNDP. 2006. Human Development Report 2006:
Beyond Scarcity: Power, Poverty, and the Global Water
Crisis. Palgrave Macmillan, New York.
UNEP. 1992. World Atlas of Desertification. Edward
Arnold, London.
UNWWAP. 2003. United Nations World Water
Assessment Programme. The World Water Development
Report 1: Water for People, Water for Life. UNESCO:
Paris, France.
USEPA (US Environmental Protection Agency).
2004. Guidelines for Water Reuse. Report EPA/625/R-
04/108, USEPA, Washington, DC, USA.
Vigneswaran, S., Sundaravadivel, M. 2004. Recycle
And Reuse of Domestic Wastewater, in Wastewater
Recycle, Reuse and Reclamation, [Ed. Saravanamuthu
(Vigi) Vigneswaran], in Encyclopedia of Life Support
Systems (EOLSS), Developed under the Auspices of the
UNESCO, Eolss Publishers, Oxford, UK,
[http://www.eolss.net]
Winward, G.P. 2007. Disinfection of greywater,
Cranfield University.
.


Generation and Quality Analysis of Greywater at Dhaka City

41
Shaikha Binte Abedin Lecturer, Department of
Civil Engineering, University of Information
Technology and Science, Dhaka, Bangladesh.
Main research area: Water Pollution and Control, Air
pollution and Control, Hydrology, Hydro-
meteorology, Remote sensing.
Address: Jamalpur Twin Tower (Tower 2),
Baridhara View, GA - 37/1 Pragati
Sharani, Baridhara, J-Block, Dhaka
1212, Bangladesh.
Tel.: +8801675583062
E-mail: shaikha.abedin@gmail.com

Zubayed Bin Rakib Lecturer, Department of Civil
Engineering, Presidency University, Dhaka,
Bangladesh.
Main research area: Climatology and Hydro-
meteorology, Hydrology, Air/Water pollution and
Control, Sustainable Development, Remote sensing.
Address: 11/A, Road 92, Gulshan, Dhaka,
1212, Bangladesh
Tel.: +88 01717 000836
E-mail: zubayed_51@hotmail.com




Paplav susidarymo ir kokybs analiz Dakos mieste

Shaikha Binte Abedin
1
, Zubayed Bin Rakib
2


1
Statybos ininerijos katedra, Informacini technologij ir moksl universitetas, Daka, Bangladeas
2
Statybos ininerijos katedra, Prezidentinis universitetas, Daka, Bangladeas


(gauta 2013 m. balandio mn., priimta spaudai 2013 m. birelio mn.)

Gamtinis iteklius vanduo nra laisvai prieinamas daugeliui pasaulio moni. Daugjant
pasaulyje moni ir didjant urbanizacijai, auga vandens poreikis. Dl didjanio vandens
naudojimo vykdant intensyvi emdirbyst besivystaniose alyse ir neefektyvaus vandens
naudojimo paangiose valstybse labai trksta tyro vandens visame pasaulyje ir jo trks ateityje.
iuo metu pasaulis yra krykelje, kai nedarnus ir nepraktikas vandens naudojimas negali bti
toleruojamas. Btinas vandens perdirbimas ir antrinis panaudojimas kai kuriuose regionuose,
norint tenkinti didjant vandens poreik miesto, pramons ir ems kio reikmms. Paplavos,
apibdinamos kaip nuotek i pastat srautas, netraukiant tualet nuotek, gali bti potencialus
antrinio vandens panaudojimo altinis miestuose, nes jame yra maai arba visai nra patogen ir
90 proc. maiau azoto nei bendrose nuotekose. iame straipsnyje apraomas paplav susidarymas
ir j kokyb Dakos mieste. Kasmet Dakos mieste gruntini vanden kiekis sumaja 2/3 metro.
Todl vandens antrinis panaudojimas tampa labai aktualus, siekiant kompensuoti gruntinio
vandens trkum. Siekiant vertinti paplav susidarym Dakos mieste, buvo analizuoti penki nam
kiai. Nustatyta, kad apie 67 proc. vandens gali bti antr kart naudotinas, o 17 proc. vandens
buvo uterta tualeto nuotekomis. Atliekant kokybin analiz nustatyta, kad virtuvs paplav
vanduo buvo i dalies utertas, todl antriniam naudojimui jis nra tinkamas. Paplav vanduo turi
bti valomas prie naudojant j antr kart, nes jo utertumas virija bet kokius priimtinus
geriamo ir drkinimui skirto vandens standartus.

También podría gustarte