Emergency lighting

systems with central


power supply.
ONLITE group and
central battery systems
excel by combining
maximum functionality
with seamless integra-
tion into the general
lighting system. They
are continuously moni-
tored high-performance
systems and guarantee
comprehensive safety.
ONLITE central
ONL I T E CENT RAL L PS 12
ONL I T E CENT RAL CPS 22
CPS system features 22 23
Colour Touch PC 24 27
CPS module summary and application areas 28 29
Circuit and individual luminaire monitoring 30 31
CPS modular units: stations, cabinets, batteries 32 37
System topology 38 39
Design tips 40 41
CPS system project planning in six steps 42 45
PRODUCT CATAL OGUE 46
TABL E OF CONT ENT S 3
The ONLITE range 4 5
Benefits of an integrative emergency lighting solution 6 7
ONLITE look escape sign luminaires 8 9
ONLITE central LPS and CPS systems compared 10 11
LPS system features and system sizes 12 13
EPS 360 Controller 14 15
Cost comparison and design table 16 17
System topology 18 19
Design tips 20 21
The ONLITE range
Complete with safety
Group and central battery sys-
tems meet extremely exacting
safety, functionality and flexibility
requirements. The emergency
lighting system can be connect-
ed to the lighting control system
so that it forms a single func-
tional unit with the general light-
ing system. Every escape sign
luminaire and every emergency
luminaire can be individually
controlled. This plus the major
advantage of central monitor-
ing the majority of control and
documentation tasks are auto-
mated.
ONLITE central
Emergency lighting systems
with central power supply
ONLITE local
Emergency lighting system
with separate battery supply
Ideal for small to medium-sized
projects: this self-contained
emergency lighting system
requires little design and instal-
lation but stands out thanks to
extreme intrinsic safety. A raft of
intelligent functions makes for
convenient operation and cuts
operating costs.
www.zumtobel.com/onlite
PRODUKT NAME SEI T ENT HEMA 5 T HE ONL I T E RANGE 5
Functional design and high-
grade materials facilitate the
integration of emergency
lighting in architectural terms.
Almost every Zumtobel luminaire
can be supplied as a prewired
emergency luminaire.
ONLITE look
Escape sign luminaires and
emergency luminaires
ONLITE service
Services
Which is the right emergency
lighting system? Besides the
size of the building, customer-
specific requirements also play
an important role. Zumtobel
offers expert professional assist-
ance in choosing a system and
can provide know-how and
manpower for designing and
commissioning. The experts
skills and many years of experi-
ence ensure the right solution is
chosen.
Almost every Zumtobel general
lighting luminaire is also avail-
able as an emergency luminaire.
This means that separate emer-
gency luminaires are no longer
needed, and makes it possible
to preserve the consistent feel
of a room. Precise planning
gives peace of mind that the
lighting result achieved in the
event of an emergency will sat-
isfy applicable regulations and
allow safe evacuation of danger
spots.
Besides visual integration of
emergency lighting, functional
integration in particular offers
additional benefits. These range
from individual addressing
through to daylight-based con-
trol of all luminaires. Integrated
emergency lighting uses the
same control systems as light-
ing management and therefore
offers perfect functionality.
All ONLITE systems support
central monitoring of emergency
luminaires, which minimises
operating costs. All specified
function tests and service life/
annual system tests are run
automatically, and the system
produces a test log book and
outputs an alarm when an
error occurs. Remote control
and remote maintenance offer
additional convenience. This
way, ONLITE systems ensure
maximum operational reliabil-
ity, easing much of the burden
of responsibility placed on the
operator.
In situations where lofty ambi-
tions are to be fulfilled, the
requirements placed on every
component without which a
room impression and ideal
working conditions are unimag-
inable are equally exacting: light
as an integral, interdisciplinary
safety factor. Most luminaire
manufacturers concentrate
exclusively on general lighting,
the lighting control sector takes
care of lighting management,
and other sectors offer emer-
gency lighting. Zumtobel cus-
tomers can rely on skills which
encompass all these areas for
project-oriented lighting solu-
tions, enabling individual appli-
cation-specific implementations
to build into a highly functional
across-the-board system.
A single unit: general light-
ing and emergency lighting
A single network for emer-
gency luminaires and light-
ing management
Automation slashes operat-
ing costs
Integrative lighting solutions
Comprehensive safety demands a holistic concept
PRODUKT NAME SEI T ENT HEMA 7 I NT EGRAT I V E L I GHT I NG SOL UT I ONS 7
Nothing conspicu-
ous catches the eye
and that's the whole
point. The emergency
luminaires are unrec-
ognizable as such and
look like part of the
general lighting. Noth-
ing interferes with the
room impression, and
the architecture can
exert its full effect
unchallenged. Unobtru-
sively designed illumi-
nated escape signs only
attract attention when
there is an emergency
situation.
ONLITE look
Escape sign luminaires with functional variety
ARTSIGN
A little design sensation
ARTSIGN is the smallest escape
sign luminaire in the world.
About the same size as a post-
card, this architects favourite
blends harmoniously into any
room, has a recognition range of
15 m and despite its size meets
all the standards. It will operate
reliably for many years without
requiring the slightest atten-
tion. High-power LEDs ensure
a long service life and complete
maintenance-freedom. The very
latest lighting technology and
a high efficiency level make it
possible to backlight the escape
route sign at a luminance level
in conformity with relevant
standards of 200 cd/m.
Design: Matteo Thun
COMSIGN
Lightweight and transparent
COMSIGN stands out thanks to
its lightweight, transparent look
and radiant backlit acrylic panel.
Its cover, with the escape route
symbol, has a recognition range
of 26 m and is made of die-
cast aluminium the housing
is made of polycarbonate. The
highly uniform backlighting is
further evidence of high quality.
COMSIGN is easy to install in
any situation and is compatible
with the TECTON continuous-
row lighting system. This makes
it ideal for use in prestigious
interiors such as foyers, offices
or even retail areas.
Design: Matteo Thun
ONL I T E L OOK 9
PURESIGN
Innovative LED technology
A special 3 mm thick aluminium
frame, a shallow mounting
height and a recognition range
of 13 m are among PURESIGNs
external features. The interior
of the escape sign luminaire
accommodates the very latest
LED and lighting technology.
These ensure perfect back-
lighting of the pictogram with
extremely high uniformity and
luminance of at least 200 cd/m.
In the case of the luminaire for
surface mounting on walls, an
additional LED spot directed
towards the escape route
increases the visibility of escape
doors. Various installation
options are further evidence of
its wide variety of applications.
Design: EOOS
ECOSIGN
The all-rounder
The all-rounder in the ONLITE
range combines all these prac-
tical qualities. Whether under
harsh conditions or in unpro-
tected areas ECOSIGN is
equipped for any kind of use
thanks to its high degree of
protection. It is flexible in every
respect and TECTON-compat-
ible. Its plus points are rounded
out by a 30 m recognition
range, and maintenance without
the use of any tools.
ECOSIGN Safety, an emergency
luminaire with outstanding tech-
nical lighting features for illumi-
nating escape routes, is a par-
ticular highlight of the ECOSIGN
product line.
Design: Matteo Thun
ONLITE central systems
Individual requirements demand individual solutions
ONLITE central LPS *
The ONLITE group battery
system excels by combining
maximum functionality with
seamless integration into the
general lighting system. Sev-
eral self-contained systems
ensure straightforward installa-
tion and quick commissioning.
For buildings with
50 to 150
emergency luminaires
Characteristics
Four basic sizes: power in
emergency mode 360, 720,
1080 or 1440 W
3 to 12 circuits, each for 20
luminaires
Monitoring of individual lumi-
naires and circuit monitoring
Mixed operation within one
circuit is possible
Individually adjustable emer-
gency power level for every
luminaire
Benefits
Straightforward ordering from
catalogue thanks to standard-
ised basic sizes
Extremely simple installa-
tion without E30 fire-resistant
cables within fire compartment
Highly flexible in the event of
changes and extensions
Optimised battery capacities
reduce both costs and envi-
ronmental pollution
Easy connection to lighting
management system
* LPS = Low Power Supply system
(acc. to EN 50172)
ONLITE central CPS *
For buildings with
more than 100
emergency luminaires
Every central battery system is
designed project-specifically
on the basis of a modular sys-
tem. This produces solutions
which are optimised in terms
of the cost and functionality of
the system.
Characteristics
Power in emergency mode
from 1 to 30 kW
Up to 180 power circuits,
each for 20 luminaires
Up to 6 substations per cen-
tral station
Mixed operation within one
circuit is possible
Between 8 and 144 freely
assignable switching inputs
Web browser-based user
interface
Benefits
Customised systems
No need for additional mod-
ules for luminaires because
every DALI luminaire can be
used as an emergency lumi-
naire
Straightforward design and
ordering
Simple commissioning
Flexible methods of connec-
tion
Can be integrated into existing
building management systems
Remote indication and remote
maintenance over the Internet
ONL I T E CENT RAL SYST EM SUMMARY 11
* CPS = Central Power Supply system
(acc. to EN 50172)
ONLITE central LPS
Self-contained group battery system for
excellent failure safety
The safety, flexibility and func-
tionality of emergency lighting
are underpinned by a small,
self-contained group battery
system.
ONLITE central LPS allows to
control and monitor every lumi-
naire individually. Emergency
lighting is integrated into the
general lighting system and
connection to the lighting man-
agement system is obtained via
DALI. As many group batteries
as required can be networked
using Ethernet in order to be
able to control and monitor
essential functions via a graphi-
cal user interface.
ONL I T E CENT RAL L PS 13
LPS system sizes
High level of
safety
Less
effort on instal-
lation
Impressive
cost effects
Entire system is split up into
several self-contained units
Shorter cable lengths reduce
fire loads by up to 45 %
Individual failure or error noti-
fication
Flexibly programmable emer-
gency lighting levels allow
lower battery capacities
DALI compatibility ensures
straightforward, affordable
integration into general lighting
system
Built-in staircase lighting func-
tion
Communication based on
Powerline (mains cable)
No E30 fire-resistant cables
within a fire compartment
25 % lower installation costs
thanks to subdivision of entire
system
Available ex works: lumi-
naires with an emergency
lighting module
Configure on the Internet and
place order using automatically
generated order number: every
Zumtobel luminaire is factory-
fitted with the requisite NSI
emergency lighting module for
individual monitoring.
ONLITE central LPS is a
modular system and offers
an effective, affordable
solution for every applica-
tion. The system is sup-
plied as a fully assembled
and wired switch cabinet.
LPS 360 LPS 720 LPS 1080 LPS 1440
Circuits (each for 20 luminaires) 3 6 9 12
Power per AC circuit 660 Watt 660 Watt 660 Watt 660 Watt
DC output power 360 Watt 720 Watt 1080 Watt 1440 Watt
Standby operating time 1 hr and 3 hrs 1 hr and 3 hrs 1 hr and 3 hrs 1 hr and 3 hrs
PCA
control gear
NSI
emergency lighting
module
+
The EPS 360 Controller is the
core of every ONLITE central
LPS system. Depending on
the size of the system, several
of these self-contained units
are installed in order to ensure
maximum possible redundancy
and hence optimum safety.
Characteristics and capabilities
of EPS 360 Controller
Mains monitoring
Control of power circuits and
luminaires
Charging unit for batteries
including battery charging
regulator
Switchover device to change
from mains-powered operation
to emergency operation
Transformer for emergency
supply from the batteries
Touch-sensitive screen for
controlling and configuring
All settings and test logs are
stored in non-volatile memory.
No data loss even in event of
complete shutdown (mains and
battery power).
Monitoring, controlling and testing
every group from a central location
Touch-
sensitive
screen
LED function display
Up to 20 luminaires can
be connected to each of
the three output circuits
of the EPS 360 Control-
ler. The maximum per-
missible installed load
is 2.4 kW, emergency
lighting output is 360 W.
Several controllers are
installed in one ONLITE
central LPS, depend-
ing on the size of the
system.
Download the test log
book via infrared or
RS 232 interface
3 output circuits
Methods of connection
A wide variety of methods of
connection guarantees maxi-
mum flexibility. Luminaires can
be switched individually or as a
complete circuit. With the indi-
vidual method of connection, it
is possible to specify, for every
individual luminaire, whether it
is to be set up in maintained
mode, non-maintained mode or
switched via any of the switch-
ing inputs. In addition, every
EPS 360 Controller has a built-
in automatic staircase lighting
function.
Programmable test cycles
The date and time of day of all
function and service life/annual
system tests can be user pro-
grammed. This prevents tests
being performed at inopportune
times, e.g. while a film is being
shown in a cinema.
Electronic test log book
All function and service life/
annual system tests are logged
and stored in the electronic test
log book of the EPS 360 Con-
troller for at least three years.
The test log book can be read
out at any time via an infrared or
RS 232 interface.
ONL I T E CENT RAL L PS 15
Flexible illuminance levels
cut costs and reduce environmental impact
In the case of conventional
emergency lighting solu-
tions with non-programmable
emergency lighting levels,
output in emergency mode
is identical to that in normal
(mains operation) mode. This
requires relatively high bat-
tery capacities and results in
higher energy consumption.
100 %
Luminaire 1
100 %
Luminaire 3
100 %
Luminaire 2
100 %
Emergency lighting level = 100 % of dimming level
at mains-powered operation
90 %
80 %
70 %
60 %
50 %
40 %
30 %
20 %
10 %
0 %
Luminaire 1
30 %
Luminaire 3
20 %
Luminaire 2
10 %
100 %
Flexible emergency lighting levels allow use of
smaller battery systems
90 %
80 %
70 %
60 %
50 %
40 %
30 %
20 %
10 %
0 %
In most cases, 10 % of the
lumen package of the mains
lighting is sufficient to guaran-
tee minimum illuminance when
operating in emergency mode.
The programmable emergency
lighting level minimises system
costs because sets of batteries
and central installations can be
designed considerably smaller
and this also helps reduce envi-
ronmental pollution.
Comparison:
conventional solution
ONLITE central LPS with
programmable emergency
lighting levels
Emergency lighting level at the
push of a button
The emergency lighting level is
set on the touch-sensitive dis-
play of the EPS 360 Controller.
These values, based on pho-
tometric calculations, can be
entered one circuit at a time or
for each individual luminaire.
Zumtobel luminaires with DALI
dimmable ballasts (luminaire
names starting with LDE) allow
individual definition of the dim-
ming level in emergency oper-
ating mode. The emergency
luminous flux of emergency
luminaires can be reduced
gradually down to 5 % of the
normal lighting.
Circuit 1 120 W 13 x 11.5 W = 149.5 W (DC) = < 160 W
Circuit 2 120 W 10 x 11.5 W = 115.0 W (DC) = < 160 W
Circuit 3 120 W 11 x 8.0 W = 88.0 W (DC) = < 160 W
Total 360 W = 352.5 W (DC) = < 360 W
Light Wattage P AC [W] P DC [W] P DC [W] P DC [W] P DC [W] P DC [W] P DC [W] P DC [W] P DC [W] Control gear
source at incl. incl. incl. incl. incl. incl. incl. incl.
Emergency lighting 230 V PLC-DALI PLC-DALI PLC-DALI PLC-DALI PLC-DALI PLC-DALI PLC-DALI PLC-DALI
level 5 % 10 % 15 % 20 % 30 % 40 % 50 % 70 %
LED 6.3 0.9 1.3 1.6 2.2 2.9 3.3 4.1 ARTSIGN
T16 1/8 W 17.0 4.5 4.5 4.5 5.0 5.5 5.5 6.0 PC Board 8 W
T16 1/14 W 19.3 7.6 8.3 9.0 9.8 11.2 12.6 13.8 16.1 PCA excel one4all lp
T16 2/14 W 37.4 11.7 12.9 14.2 15.4 18.1 20.8 23.5 29.2 PCA excel one4all lp
T16 1/21 W 26.3 7.7 8.5 9.5 10.5 12.6 14.6 16.8 21.0 PCA excel one4all lp
T16 2/21 W 49.7 11.9 14.0 16.3 18.4 22.7 26.5 30.3 38.8 PCA excel one4all lp
T16 1/24 W 29.9 9.1 10.1 11.3 12.6 15.0 17.7 20.3 24.6 PCA excel one4all lp
T16 2/24 W 58.2 16.1 18.5 21.2 23.7 29.2 34.1 38.9 48.0 PCA excel one4all lp
T16 1/28 W 34.8 8.7 10.1 11.6 13.1 16.0 18.8 21.7 26.4 PCA excel one4all lp
T16 2/28 W 66.7 15.0 17.9 20.7 23.4 29.1 34.4 39.8 51.3 PCA excel one4all lp
T16 1/35 W 42.4 8.8 10.5 12.3 14.0 17.6 21.3 25.1 31.4 PCA excel one4all lp
T16 2/35 W 80.9 14.8 18.0 21.6 25.1 32.4 39.3 46.2 61.4 PCA excel one4all lp
T16 1/39 W 45.0 10.2 12.0 13.9 16.0 20.0 23.6 27.4 35.3 PCA excel one4all lp
T16 2/39 W 88.5 16.1 20.0 24.1 28.2 36.0 44.0 52.0 68.3 PCA excel one4all lp
T16 1/49 W 57.6 10.0 12.4 14.9 17.6 22.8 28.1 33.4 43.7 PCA excel one4all lp
T16 2/49 W 109.7 17.3 22.1 27.1 32.3 42.3 52.1 62.0 82.9 PCA excel one4all lp
T16 1/54 W 64.5 13.6 16.2 19.0 21.9 27.4 32.8 38.0 49.5 PCA excel one4all lp
T16 2/54 W 124.7 23.4 29.2 34.9 40.7 52.7 63.3 73.9 95.7 PCA excel one4all lp
T16 1/80 W 91.2 14.9 18.9 23.1 27.4 35.5 43.9 52.3 68.4 PCA excel one4all lp
T26 1/18 W 26.0 8.5 9.5 10.5 12.0 13.0 13.5 16.5 PCA excel one4all
T26 2/18 W 43.0 16.0 17.5 19.0 23.0 25.0 26.5 28.0 PCA excel one4all
T26 1/30 W 34.0 9.5 11.5 13.0 15.5 18.5 20.5 25.0 PCA excel one4all
T26 2/30 W 61.0 16.0 19.0 22.0 28.0 32.5 37.5 45.5 PCA excel one4all
T26 1/36 W 42.0 12.5 15.0 16.5 20.0 22.0 24.5 28.5 PCA excel one4all
T26 2/36 W 74.0 22.5 26.5 30.5 36.0 40.0 43.5 53.5 PCA excel one4all
T26 1/58 W 61.0 17.5 21.0 24.5 29.0 33.5 37.5 45.5 PCA excel one4all
T26 2/58 W 110.0 31.5 37.5 44.5 53.5 60.5 67.5 83.5 PCA excel one4all
TC-L/F 1/18 W 24.0 6.0 6.5 7.5 8.5 9.5 10.5 12.5 PCA excel one4all
TC-L/F 2/18 W 41.0 9.0 10.5 12.0 14.0 16.5 18.5 23.5 PCA excel one4all
TC-L/F 1/24 W 31.0 9.0 11.0 12.5 15.0 17.0 19.0 22.5 PCA excel one4all
TC-L/F 2/24 W 53.0 14.5 17.5 20.5 25.5 30.5 34.5 42.5 PCA excel one4all
TC-L/F 1/36 W 39.0 12.0 14.5 16.5 20.5 24.0 26.5 32.5 PCA excel one4all
TC-L/F 2/36 W 73.0 18.5 22.5 27.0 33.5 40.0 46.0 59.5 PCA excel one4all
TC-L/F 1/40 W 50.0 14.5 17.5 20.5 23.5 26.5 29.5 36.5 PCA excel one4all
TC-L/F 2/40 W 90.0 26.5 31.0 35.5 44.5 51.5 57.5 72.5 PCA excel one4all
TC-L/F 1/55 W 63.0 16.5 23.0 29.5 28.5 34.5 39.5 52.5 PCA excel one4all
TC-L/F 2/55 W 121.0 30.5 38.5 46.5 58.0 67.5 76.5 101.5 PCA excel one4all
TC-S/E 1/11 W 19.0 6.5 7.5 8.0 9.5 10.5 11.5 13.0 PCA excel one4all
TC-S/E 2/11 W 33.0 9.5 11.5 13.0 12.5 13.5 14.5 24.0 PCA excel one4all
TC-D/E 1/13 W 20.0 6.5 8.0 8.5 10.0 11.0 12.0 14.0 PCA excel one4all
TC-D/E 2/13 W 33.0 10.0 12.0 13.5 16.0 19.0 21.5 26.0 PCA excel one4all
TC-D/T 1/18 W 24.0 7.0 8.5 9.5 11.5 13.5 15.0 18.0 PCA excel one4all
TC-D/T 2/18 W 43.0 13.0 15.5 17.5 21.5 24.5 27.5 34.0 PCA excel one4all
TC-D/T 1/26 W 33.0 10.0 12.0 13.5 16.5 18.5 20.5 24.5 PCA excel one4all
TC-D/T 2/26 W 57.0 16.5 20.5 23.5 29.5 34.0 38.5 46.5 PCA excel one4all
TC-T/E 1/32 W 36.0 10.5 13.5 15.5 19.5 22.5 25.5 30.5 PCA excel one4all
TC-T/E 2/32 W 66.0 17.5 22.5 27.0 34.5 41.5 48.0 59.5 PCA excel one4all
TC-T/E 1/42 W 47.0 12.0 15.0 17.5 22.5 27.5 31.0 39.5 PCA excel one4all
TC-T/E 2/42 W 88.0 23.5 29.0 34.5 43.5 52.0 59.5 77.5 PCA excel one4all
TC-DD 1/55 W 60.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PCA excel one4all
NV DSI 70 W 70.0 58.0 58.0 58.0 58.0 58.0 58.0 58.0 TEL 70 VA
NV DSI 105 W 105.0 85.0 85.0 85.0 85.0 85.0 85.0 85.0 TEL 105 VA
NV DSI 150 W 150.0 90.0 90.0 90.0 90.0 90.0 90.0 90.0 TEL 150 VA
NV DSI 210 W 210.0 137.0 137.0 137.0 13.0 137.0 137.0 137.0 TEL 210 VA
NV DALI 105 W 105.0 85.5 85.5 85.5 85.5 85.5 85.5 85.5 TEL one4all 105 VA
NV DALI 150 W 150.0 90.5 90.5 90.5 90.5 90.5 90.5 90.5 TEL one4all 150 VA
ONL I T E CENT RAL L PS 17
The number of lighting points
can be increased by reducing
the output of the luminaires
Output per controller:
360 W total emergency light-
ing output for 1 or 3 hours
depending on battery set
3 output circuits, each for up
to 20 luminaires
Each output circuit rated 120 W
(160 W max.) in DC operation
and 660 W in AC operation
LUXMATE bus
3 (L, N, PE) up to 20 luminaires
Lswitching conductor
L1, L2, N, PE
Emergency luminaire
switched (L)
Emergency luminaire Emergency luminaire Emergency luminaire
Mains-powered
luminaire
Mains-powered
luminaire
Escape sign luminaire
switched (L)
Emergency luminaire
switched (L)
Emergency luminaire
switched (L)
Emergency luminaire
switched (L)
3 (L, N, PE) up to 20 luminaires
3 (L, N, PE) up to 20 luminaires
FI
HVA UVA
ONLITE central EPD
Order no. 22.156.808
UV1
DALI 2 x 1,5 mm
2
DALI input is optional
(if it is used, local and central switching is no longer possible)
ONLITE IR printer
Order no. 22.154.522
Infrared
LM-DALIS
LM-DALIS
L1
L2
L3
N
PE
N L3 L2 1
1 4
ONLITE central LPS
System topology
EPS 360
ok
Circuit 1, luminaire 1
100 10 AC % DC %
Test Status: OK
Site: Plant 23
Lamp: T 16 35 W
Inform: TECTON assembly bay 12
EPS 360
Circuit 1, luminaire 1
E
L
1
E
N
1
P
E
E
L
2
E
N
2
P
E
E
L
3
E
N
3
P
E
S
1
S
3
E
l
1
E
n
1
P
E
E
l
2
E
n
2
P
E
E
l
3
E
n
3
P
E
S
1
S
3
L
S
L
S
NNP
E
K
1
1
K
1
2
K
1
4
K
2
1
K
2
2
K
2
4
K
3
1
K
3
2
K
3
4
ONLITE central LPS 720 1h10
Order no. 22.156.821
Battery cable Battery cable
ONLITE central EPD
Order no. 22.156.808
ONLITE central EPD
Order no. 22.156.808
UV2 UV3
ONLITE central
Remote interface
Order no. 22.161.513
Switching inputs,
optional
(only possible if
there is no DALI input)
S
2
_
1
S
3
_
1
S
2
_
2
S
3
_
2
N
S
4
_
1
S
5
_
1
S
5
_
2
S
4
_
2
In
d
ic
a
tio
n
+
In
d
ic
a
tio
n
-
E
m
e
rg
e
n
c
y
o
ff +
E
m
e
rg
e
n
c
y
o
ff -
L
'1
L
'2
P
H
W
1
-
P
H
W
1
-
P
H
W
2
+
P
H
W
2
-
S
y
n
c
+
S
y
n
c
-
K
1
1
C
i
r
c
u
i
t

1
C
i
r
c
u
i
t

2
C
i
r
c
u
i
t

3
S1a S1b S1c
Ready for operation
Operation from battery
Fault
K
2
1
K
3
1
U
b
+
G
n
d
S
w
i
t
c
h
L1
L2
L3
N
PE
N L3 L2 1
1 4
L1
L2
L3
N
PE
N L3 L2 1
1 4
Off
cancel ok
100 10 AC % DC %
Test Status: OK
Site: Plant 23
Lamp: T 16 35 W
Inform: TECTON assembly bay 12
cancel
ONL I T E CENT RAL L PS 19
Notes:
Only ONLITE Powerline
de vices and the control gear
to be controlled may be
connected to the EPS 360.
External consumers or inter-
ference sources must not be
connected to the Powerline
network.
Band-stop filters or filters are
not permitted in the Powerline
domain.
Where the length of parallel
cable runs cannot be restrict-
ed to 10 m, cables which are
parallel must be spaced at
least 5 cm apart.
The maximum cable length is
300 m (1.5 to 4 mm
2
).
Individual monitoring of
luminaires
With individual monitoring of
luminaires, there is an intelligent
monitoring module inside every
emergency luminaire which
communicates with the cen-
tral emergency lighting power
source via Powerline. Every
emergency luminaire is assigned
a unique luminaire address at
the time of commissioning. This
makes it possible to display the
status of each individual emer-
gency luminaire on the ONLITE
central LPS.
Monitoring of circuits
An EPS 360 Controller which
measures the power output
into its output circuit in order to
ascertain whether all the lumi-
naires in the circuit are oper-
ating correctly is a distinctive
feature of this circuit monitoring.
In the case of circuit monitoring,
only circuit-wide switching is
possible.
Benefits
When an emergency
luminaire fails, the
location of the faulty
luminaire is pinpointed.
Emergency luminaires
in one output circuit
can be individually
configured to various
methods of connec-
tion.
Emergency luminaires
can be integrated into
DALI lighting control.
Emergency lighting
level can be pro-
grammed via central
emergency lighting
power source.
Benefits
Luminaires do not
have to be equipped
with add-on modules.
Any load suitable for
AC/DC may be con-
nected.
ONLITE central LPS
Design tips
Circuit 1
Circuit 2
Circuit 3
Emergency power supply
Emergency power supply
Emergency power supply
Powerline
communication
ONLITE central LPS
Circuit 1
Circuit 2
Circuit 3
Emergency power supply
Emergency power supply
Emergency power supply
ONLITE central LPS
P
circuit
ONL I T E CENT RAL L PS 21
Integration into a lighting
management system
The DALI interface ensures that
emergency lighting can be inte-
grated seamlessly into general
lighting. DALI commands are
converted to Powerline signals
and are sent to the emergency
and escape sign luminaires. This
way, every luminaire can be indi-
vidually controlled and included
in automation processes.
LUXMATE lighting control sys-
tems make it possible to fully
exploit a whole raft of advan-
tages offered by ONLITE central
LPS.
The ONLITE GO-ON package
visualisation module provides
users with a convenient facil-
ity for monitoring their entire
ONLITE emergency lighting sys-
tem from one central location.
Perfectly planned monitoring
systems link up the group or
separate battery systems in one
or more buildings into an intelli-
gent information network, which
delivers information on the sta-
tus of the emergency lighting
system round the clock.
Central monitoring using
GO-ON package
230 V AC
230 V AC/ DC
Emergency power supply
ONLITE central LPS
DALI
DALI
TCP/IP network
GO-ON
package
ONLITE central LPS
ONLITE central CPS
Project-specifically customised, networked
central battery system
The modular design of ONLITE
central CPS guarantees a
tailor-made solution for any
project and a significantly opti-
mised cost/functionality ratio.
Every ONLITE central CPS
offers full functionality in order
to comprehensively meet the
requirements placed on a cen-
tral battery system using as few
components as possible. No
additional software or modules
are needed.
There is no need to fit any
separate components in the
luminaire because every DALI
luminaire can be used as an
emergency luminaire which can
be individually monitored and
controlled.
This also reduces effort on
commissioning, inspecting and
maintaining the system. A large
removable Touch PC is the core
of the system. It enables, for
example, straightforward com-
missioning by one person, or
neatly laid out, easily manage-
able display of the systems
status.
ONL I T E CENT RAL CPS 23
Every DALI luminaire
in Zumtobels standard
product range is an
emergency luminaire
Every DALI luminaire can be
used as an emergency luminaire
which can be individually moni-
tored. No additional modules
need to be fitted to achieve this,
and functionality of the general
lighting system is completely
preserved.
This simplifies project planning,
reduces both costs and effort
and makes choosing lumi-
naires easy. Delivery times for
emergency luminaires are short
because they are luminaires in
the standard product range.
Less effort
on design
Manageable, clearly structured
product line
Integration into lighting man-
agement system with resulting
significant technical and eco-
nomic benefits
Project-specific solutions
thanks to modular system
Full functionality as standard,
renders additional software
and modules superfluous
Design
freedom
Convenience at
every level
Simple, easily understandable
operation using removable
Touch PC
System information can be
downloaded via the Internet
by using Web browser-based
software
Function and service life/
annual system tests are run
and documented completely
automatically
Individual method of connec-
tion for each luminaire, even
within a single circuit
Combination of monitoring of
circuits and individual lumi-
naires in one system
Simple project planning thanks
to competent design support
and extensive design tools
DALI control gear
PCA
A system control centre for
operating, displaying and networking
ONLITE central CPS sets new
standards when it comes to
monitoring and display of emer-
gency lighting systems. A 7"
LED-backlit WVGA widescreen
(16:9) colour Touch PC displays
the entire installation.
Touch and control: It takes no
more than three touches to
access individual luminaire data
and status displays. All events
are recorded for at least three
years on a built-in SD card as a
test log book.
Ethernet/Internet
No extra charge:
Networkability comes as
standard
Every ONLITE central CPS
module can be displayed via the
Ethernet using a Web-based
browser without the need for
any additional software. The
system can therefore be man-
aged remotely from any PC.
Info
245.10 V
Battery voltage
Charging current
Battery temperature
0.30 A
24.00 C
Ready for operation
Test
Mains operation
Unit malfunction
Maintained light
Mains failure UVA
Luminaire failure
System bus
20.11.2007
13:52:29
ONLITE central CPS
Zumtobel
System status
Neatly laid out status display,
includes system voltage and
battery temperature among
other parameters. Faults are
displayed in plain language and
indicated visually.
Details of substations
Each of up to 7 substations
can be displayed on the central
Touch PC. This simplifies the
job of the person tasked with
maintenance and helps them
keep an overview of the entire
installation.
Details of luminaire status
Each individual luminaire is
displayed at the control centre.
As well as visual error display,
further additional information
is made available. The Touch
PC provides details of the loca-
tion, light source type, watt-
age, method of connection
and address of every individual
luminaire.
ONL I T E CENT RAL CPS 25
Operating and
displaying
Info
Ready for operation
Test
Mains operation
Unit malfunction
Maintained light
System bus
20.11.2007
13:54:17
UV summary
1 2 3
Show all faulty lamps
Info
20.11.2007
13:56:43
Luminaire status
UV new UV3
Line monitor:
Circuit 1: New circuit 1
Select
UV:
Circuits:
New UV 3
1 5
U< U< U< U< U< U< U< U<
Circuit 2: New circuit 2
Circuit 3: - - -
Circuit 4: New circuit 4
Circuit 5: - - -
Faulty luminaires only
Besides performing major sys-
tem documentation and display
tasks, the removable unit with
LED backlighting also offers
substantial benefits when com-
missioning the ONLITE central
CPS system.
This operating and control unit
plugs not only into the control
centre but also into every sub-
station for local commission-
ing, for example. Every cabinet
is equipped with a four-pole
plug connector for this purpose.
Two conductors carry the 24 V
power supply and two carry
data.

Plug-in and network
Portable Touch PC for com-
missioning
Mobile control unit
for lower costs and greater flexibility
E
S E E S
Touch PC
900 m JY (St) Y 2 x 2 x 0.8
S
E S
Touch PC
500 m JY (St) Y 2 x 2 x 0.8
E
Line topology
Free topology
ONL I T E CENT RAL CPS 27
Ethernet RJ 45 port
The large number of ports is
indicative of the high quality of
the units internal components:
the Touch PC has no rotating
parts and is therefore extremely
rugged, the Windows CE Pro
operating system is pre-installed
and it also has an SD memory
card with a storage capacity of
512 MB. A single cable is used
for the 24 V supply voltage and
the control bus.
The facility to connect to a
WLAN router allows wireless
connection between the Touch
PC and the handheld unit for
even greater convenience and
flexibility.
USB
Control bus and 24 V power supply
in one cable
JY (St) Y 2 x 2 x 0.8 mm
Status LEDs
Tailor-made emergency lighting system
Modular system for best possible price/performance ratio
Every ONLITE central CPS cen-
tral battery system is individually
tailored to a particular project.
A simple configuring tool and
sophisticated logistics manage-
ment ensure that the project is
handled straightforwardly and
promptly.
Full functionality of the installa-
tion is always available regard-
less of the system limits. An
ideal price/performance ratio is
achieved for every project by
fine tuning the system to suit
the particular project.
Even the very smallest
detail
reflects experience gained
from hundreds of projects
Powder-coated sheet-
steel cabinet, colour:
RAL 7053
Built-in Touch PC
Left-hand or right-hand
door hinge
Detachable grating for
safe transport using lift-
ing truck
Integral base with ven-
tilation slots for battery
ventilation and cooling
Large wiring space for
convenient wiring
Disconnect terminals for
all connections
Modular cabinet design for
project-specific solutions
Generous battery com-
partment with strong
shelf supports for
simple connection and
maintenance of bat-
teries
Integral collecting
trough eliminates need
for electrolyte-resistant
floor surface
Maximum energy effi-
ciency thanks to
Low-loss components
Optimal battery
capacity
Low-loss electronic
ballasts
ONL I T E CENT RAL CPS 29
S E
Modul for Modul for indi-
circuit moni- vidual monitoring
toring of luminaires
Circuits 0 20 0 20
Number of luminaires 0 400 0 400
Max. power (W) 4700 4700
Max. power per circuit (W) 1300 1300
Fuse per circuit (A) 10 10
Outgoing terminals (mm
2
) 4 4
Digital potential-free inputs 8 16 8 16
Monitoring of circuits or moni-
toring of individual luminaires
may be useful depending on the
particular application.
ONLITE central CPS caters for
specific circumstances; every
station can be designed with
both methods of connection.
Its modular system design even
makes it possible to mix mod-
ules with circuit monitoring and
modules with individual moni-
toring of luminaires within one
installation.
One to three bays are available
for monitoring modules depend-
ing on the design of the relevant
distribution cabinet. These bays
can either be fitted with mod-
ules for circuit-wide monitoring
or individual monitoring of lumi-
naires. Every module can handle
1 to 20 circuits.
Two modules
for all types of monitoring
CPS-K
compact station
E
S
E
S
Each of the two bays
can be fitted with a
module for circuit moni-
toring or individual mon-
itoring of luminaires.
CPS-H
main station
CPS-U E30
fire-resistant sub-
distribution board
E
S
Each of the three bays
can be fitted with a
sub-distribution board
for circuit monitoring or
individual monitoring of
luminaires.
The sub-distribution
board can be equipped
either for circuit moni-
toring or individual mon-
itoring of luminaires.
CPS-U E00
sub-distribution
board
E
S
The sub-distribution
board can be equipped
either for circuit moni-
toring or individual mon-
itoring of luminaires
E
S
E
S
E
S
Variable monitoring
Anything is possible: circuit, individual luminaires
or a combination of both systems
ONLITE central CPS
offers the right type
of monitoring for
every application
area station by
station. It is even
permissible to com-
bine central stations
and substations
with different types
of monitoring within
the same building.
Monitoring
of circuits
Individual monitoring
of luminaires
Circuit monitoring is used pri-
marily in extensive buildings
which have consistent lighting
concepts. Industrial factory
buildings and parking garages
are typical examples of such
buildings. Even a circuit error of
10 % can be localised in final
circuits which incorporate lumi-
naires of similar wattages.
Individual monitoring is preferred
in buildings such as shopping
malls, hospitals or museums
where there are a variety of
lighting systems. Addressable,
switchable and dimmable
standard luminaires with DALI
ballasts are used. Here too, it
is possible to set the desired
emergency power level without
any additional components.
Besides conventional DC emer-
gency operation, the built-in
security function also trips in AC
emergency mode. This guar-
antees consistent functionality,
even if the control cable is inter-
rupted or short-circuited.
Using LUXMATE LITNET, the
leading lighting system which
is used in large office buildings
in particular, allows the user to
dispense with a large proportion
of ONLITE central CPS hard-
ware and software for luminaire
monitoring. A system with circuit
monitoring is sufficient; indi-
vidual monitoring of luminaires is
taken care of by LITENET.
This way, every emergency lumi-
naire need only be addressed
once at the time of commis-
sioning.
Straightforward design and
commissioning
Use of standard luminaires
with electronic ballasts
Lower investment costs but
restricted functionality
Maximum safety
Lower operating costs
Maximum functionality

Maximum convenience and
flexibility
Many ONLITE central CPS
functions are already incor-
porated in the LUXMATE
LITENET lighting management
system
Easy commissioning
Monitoring
of circuits
using LUXMATE LITENET
ONL I T E CENT RAL CPS 31
CPS K
Compact station
Complete, including set of
batteries and wiring accesso-
ries for batteries
Up to 40 circuits, each for up
to 20 luminaires
Up to 7 substations can be
connected
Integral collecting trough
eliminates need for electrolyte-
resistant floor surface
Compact, neatly laid out cabi-
net structure
Built-in, removable Touch PC
in front door
CPS K technical data
Dimensions (H x W x D) 1800 x 850 x 600 mm
Total power 7 21 kVA
Internal circuits 0 40
Outgoing circuits to external UVS max. 7
Fuse protection UVS up to 35 A
Outgoing terminals UVS 16 mm
Battery voltage (18 blocks) 216 V
Max. battery capacity 17 75 Ah
Ethernet port x 1
Potential-free outputs x 5
Digital potential-free inputs per UVS 8 to 16
Set of batteries Weight (kg) Total weight (kg)
17 Ah 107 257
24 Ah 162 312
28 Ah 175 325
33 Ah 211 361
45 Ah 267 417
55 Ah 324 475
75 Ah 432 582
Modular ONLITE central CPS units
Stations and cabinets
CPS K
CPS U E30
Each internal or external
substation (UVS) may
be selected to monitor
circuits or individual
luminaires.
E
S
Individual monitoring
Circuit monitoring
E
S
E
S
17 Ah
24 Ah
28 Ah
33 Ah
45 Ah
55 Ah
75 Ah
UVS1 UVS2
UVS3
E
S
UVS3
17 Ah
24 Ah
28 Ah
33 Ah
45 Ah
55 Ah
75 Ah
E
S
UVS1
UVS3
E
S
E
S
E
S
UVS2 UVS7 UVS8
CPS H
Main station
Up to 60 circuits, each for up
to 20 luminaires
Up to 6 substations can be
connected
Compact, neatly laid out cabi-
net structure
Built-in, removable Touch PC
in front door
DC supply from battery cabi-
net or battery rack
CPS H
CPS U E30
CPS H technical data
Dimensions (H x W x D) 1800 x 850 x 600 mm
Total power 7 30 kVA
Internal circuits 0 60
Outgoing circuits to external UVS max. 6
Fuse protection UVS up to 35 A
Outgoing terminals UVS 16 mm
Battery outgoing terminals 35 mm
Ethernet port x 1
Potential-free outputs x 5
Digital potential-free inputs per UVS 8 to 16
ONL I T E CENT RAL CPS 33
Each internal or external
substation (UVS) may
be selected to monitor
circuits or individual
luminaires.
E
S
UVS2
UVS3
E
S
E
S
E
S
UVS4 UVS8 UVS9
E
S
UVS1
E
S
UVS3
E
S
Individual monitoring
Circuit monitoring
CPS BS
Battery cabinet including
batteries
Battery cabinet to supply main
station
System capacity from 33 to
200 Ah
One battery cabinet is suffi-
cient for a capacity of 150 Ah;
two cabinets are supplied for
190 Ah and 200 Ah
Built-in temperature sensor
Integral collecting trough
eliminates need for electrolyte-
resistant floor surface
+
33 Ah
45 Ah
55 Ah
75 Ah
80 Ah
90 Ah
100 Ah
120 Ah
134 Ah
150 Ah
190 Ah
200 Ah
Set of batteries H x W x D Weight (kg)
33 Ah 1600 x 600 x 600 211
45 Ah 1600 x 600 x 600 267
55 Ah 1600 x 600 x 600 324
75 Ah 1600 x 600 x 600 432
80 Ah 1800 x 850 x 600 472
90 Ah 1800 x 850 x 600 540
100 Ah 1800 x 850 x 600 540
120 Ah 1800 x 950 x 600 679
134 Ah 1800 x 950 x 600 765
150 Ah 1800 x 1100 x 600 836
190 Ah 1800 x 1100 x 600
1800 x 600 x 600 1167
200 Ah 1800 x 1100 x 600
1800 x 600 x 600 1206
Modular ONLITE central CPS units
Cabinets and substations
CPS BG
Battery rack
Battery rack for external
installation in battery room
Accommodates 18 OGiV
block batteries, 33 Ah to 200
Ah
Sintered PE coating, all-insu-
lated, acid-resistant longitudi-
nal bars and transverse bars
Dielectric strength tested acc.
to DIN VDE 0100 and DIN
VDE 0510 by TV
Single earth
Height-adjustable feet made
of insulating plastic
Colour: black
Protection class I
Set of batteries H x W x D Weight (kg)
33 Ah 1246 x 715 x 600 265
45 Ah 1244 x 715 x 600 321
55 Ah 1284 x 715 x 600 378
75 Ah 1289 x 715 x 600 486
80 Ah 1253 x 715 x 750 531
90 Ah 1288 x 715 x 750 599
100 Ah 1296 x 715 x 750 599
120 Ah 1301 x 715 x 900 747
134 Ah 1351 x 715 x 750 824
150 Ah 1314 x 715 x 1050 919
190 Ah 1317 x 930 x 1200 1252
200 Ah 1317 x 930 x 1200 1291
CPS U E30
Fire-resistant substation
CPS U E00
Substation
E30 substation with very com-
pact dimensions
(1376 x 374 x 334 mm)
Cable cooling compartment
High-security safe lock
Test certificate
Installation accessories includ-
ed
Connected to compact station
or main station via JY (St) Y
2 x 2 x 0.8 mm
Colour RAL 7035
Substation with unbeatably
compact external dimensions
(800 x 300 x 140 mm)
Powder-coated sheet steel,
colour RAL 7010
Easy, space-saving installation
Connected to compact station
or main station via JY (St) Y
2 x 2 x 0.8 mm
CPS U E30 technical data
Circuits 1 20
Number of luminaires 1 400
Max. power (W) 4700
Max. power per circuit (W) 1300
Fuse per circuit (A) 10*
Outgoing terminals (mm
2
) 4
Digital potential-free inputs 8 to 16
The sub-distribution
board can be equipped
either for circuit moni-
toring or individual mon-
itoring of luminaires.
E
S
Individual
monitoring
Circuit
monitoring
E
S
E
S
CPS U E00 technical data
Circuits 1 20
Number of luminaires 1 400
Max. power (W) 4700
Max. power per circuit (W) 1300
Fuse per circuit (A) 10*
Outgoing terminals (mm
2
) 4
Digital potential-free inputs 8 to 16
The sub-distribution
board can be equipped
either for circuit moni-
toring or individual mon-
itoring of luminaires.
E
S
Individual
monitoring
Circuit
monitoring
ONL I T E CENT RAL CPS 35
* Standard 6.3 A (900 W)
* Standard 6.3 A (900 W)
Modular ONLITE central CPS units
Large choice of powerful block batteries
Reliable energy
sources in the
event of mains
power failure
OGiV type BTX-LS block bat-
teries are ideally suitable for
stationary applications. Sealed,
rechargeable batteries with
a high discharge rate, these
batteries are built to the very
latest standards. With a design
life of over 10 years at 20 C,
they meet EUROBAT require-
ments for batteries classified
as high-performance. The
accessories required for bat-
tery installation are supplied.
12
Service life
(years)
Ambient temperature
(C)
10
8
6
4
2
50 20 25 30 35 40 45
EUROBAT High Per-
formance class with
design life of more than
10 years at 20 C
Grid-type plates with high dis-
charge rate (lead-calcium)
Absorptive glass mat tech-
nology
Capacity from 17 to 200 Ah in
12 V blocks
Housing and lid made of ABS
Recessed battery terminal with
brass core, internally screw-
able
Conforms to DIN EN 60896-
21:2004
Extremely low gassing
Low self discharge
100 % recyclable
Not classified as dangerous
goods for transport by road,
rail, air or inland waterway
Maintenance free
Battery temperature must be
maintained between +5 C min.
and +30 C max. in order to
obtain full battery performance.
A nominal temperature of 20 C
is ideal. The temperature differ-
ence between cells or blocks in
a battery bank must not exceed
5 C (5 Kelvin).
An electrolyte-resistant floor sur-
face in the room where batteries
are installed and acid-resistant
troughs in cabinets can be dis-
pensed with because leakproof
batteries according to DIN
EN 50272-2:2001 are used.
Notes on battery planning and
installation
!
Battery selection
table
Battery type Capacity (Ah) Dimensions Weight (kg) Terminal
(25 C, 1,8 V/cell) LWH connection
Volt C10 C8 C3 C1
12-17 12 16.6 16.4 15.6 13.8 181 x 77 x 172 5.9 M4
12-24 12 23.5 23.2 21.7 17.4 166 x 175 x 125 9.0 M5
12-28 12 27.8 27.3 24.9 20.9 165 x 125 x 175 9.7 M5
12-33 12 32.9 32.0 27.7 22.9 195 x 130 x 168 11.7 M6
12-45 12 45.3 42.9 36.3 29.0 197 x 165 x 170 14.8 M6
12-55 12 56.0 54.1 47.0 38.7 229 x 138 x 213 18.0 M6
12-75 12 73.0 70.3 57.9 46.2 258 x 166 x 215 24.0 M6
12-80 12 81.3 76.9 65.1 53.9 350 x 167 x 179 26.2 M6
12-90 12 91.6 86.7 72.6 60.5 306 x 169 x 214 30.0 M6
12-100 12 101.9 98.2 86.1 70.0 330 x 171 x 222 30.0 M6
12-120 12 122.5 118.1 104.5 81.5 410 x 176 x 277 37.7 M8
12-150 12 153.4 146.1 124.9 102.6 485 x 172 x 240 46.4 M8
12-190 12 184.3 175.0 153.1 124.6 522 x 238 x 223 64.8 M8
12-200 12 204.8 198.1 175.3 143.7 522 x 238 x 223 67.0 M8
Technical data
ONL I T E CENT RAL CPS 37
Volt trickle-charge voltage: 2.3 V/cell
Temperature compensation 20 mV/1 C
ONLITE central CPS
System topology
info
?
<
>
ONLITE central
Touch PC
S5- Rel5 Rel6 Rel7 GND 24V A B S5+
2
4
V
0
V
2

x

5
L
1
L
2
L
3
N
P
E
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

2
x
4
S
3
S
2
S
4
S
5
S
6
S
7
A
1

+
A
1

P
E
A
2

+ +
-
A
2

A
x

+
A
x

3 3

+
3
2

2
x
1
=
~
J
Y

(
S
t
)

Y
2

x

2

x

0
,
8
HVA
HVS
LE loading unit
Emergency-off
By pressing the emergency-off
button, the complete ONLITE
central CPS system (including
all substations) is disconnected
from power supply. This ensures
that emergency forces can
safely do their job. The internal
+24 V supply is carried via an
NC switch (emergency-off) and
connected to the S5 terminal
(2 x 1 terminal strip at the main
station), while the configuration
is adjusted to the emergency-off
function using the touch PC.
Control and
display unit
B
l
o
c
k
i
n
g

t
h
e

s
y
s
t
e
m
R
e
a
d
i
n
e
s
s

f
o
r

s
e
r
v
i
c
e
C
e
n
t
r
a
l
i
s
e
d

f
a
u
l
t
O
p
e
r
a
t
i
o
n

f
r
o
m

b
a
t
t
e
r
y
Optional
System emergency-off
Battery
216 V
T
e
m
p
e
r
a
t
u
r
e

s
e
n
s
o
r

M
a
i
n
s

f
r
o
m

H
V
A

F
a
n

f
a
u
l
t

i
n
d
i
c
a
t
i
o
n

M
a
i
n
t
a
i
n
e
d

l
i
g
h
t

o
n
/
o
f
f
N
o
t

a
s
s
i
g
n
e
d
N
o
t

a
s
s
i
g
n
e
d
Relay output (potential-free)
t
o

U

V
S

1

t
o

U

V
S

2

t
o

o
t
h
e
r

U
V
S
Power supply
bus 24 V
ONL I T E CENT RAL CPS 39
UVA 1 UVA 2
UVS
UVS circuit monitoring
UVS
UVS individual
monitoring
dig. input
24 V / DC
dig. input
24 V / DC
Systembus
24 V
Recommendation:
We recommend that you use a 5-pole cable to connect the out-
going circuits.
To next UV

To next UV
Systembus
24 V
NW1
L1
L2
L3
N
PE
N L3 L2 L1
1 4 FI
NW2
L1
L2
L3
N
PE
N L3 L2 L1
1 4 FI
+
-
+
-
A
D
1
2
P
E
1 2 3 4 5 6 7 8 9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
A
D
1
2
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
A
D
1
2
A
D
1
2
A
D
1
2
A
D
1
2
A
D
1
2
A
D
1
2
A
D
1
2
A
D
1
2
B
D
1
2
1
2
B
D
1
2
1
2
B
D
1
2
1
2
B
D
1
2
1
2
B
D
1
2
1
2
C
D
1
2
1
2
C
D
1
2
1
2
C
D
1
2
1
2
C
D
1
2
1
2
C
D
1
2
1
2
D
D
1
2
1
2
D
D
1
2
1
2
D
D
1
2
1
2
D
D
1
2
1
2
D
D
1
2
1
2
5
x
1
3 3 2
B
1
+
B
1

P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
S
1
S
2
S
8
[
.
.
.
]
5
x
1
B
1
+
B
1

P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
P
E
S
1
S
2
S
8
[
.
.
.
]
E30
J
Y

(
S
t
)

Y
2

x

2

x

0
,
8
J
Y

(
S
t
)

Y
2

x

2

x

0
,
8
4
x
2
4
x
3
5
x
2
5
x
3
Potential-free
inputs
Every ONLITE central CPS main
station and substation provides
eight digital potential-free inputs
as standard. The first input (S1)
is designed as a critical circuit
and, as a rule, is used for the
phase detector loop. Several
phase detector loops or other
potential-free switching inputs
can be parameterised. Each of
the switching inputs is connect-
ed to the internal 24 V reference
potential. Eight other potential-
free inputs are optionally avail-
able for each ONLITE central
CPS station.
UV1
+ 24 V
1
2
8
9 16 digital in
Phase detector loop
Optionally: 8 additional expansion inputs
Mains L for external switching inputs
L1
L2
L3
N
PE
N L3 L2 L1
1 4
UVA 1
FI
Mains L for external switching inputs
ONLITE central CPS
Design tips
digital in
DALI
DALI
8 16 digital in
Phase detector loop
E30
Data
Mains-
emergency
E
CPS-U
E30
CPS-K
1 A|
24 A|
28 A|
JJ A|
45 A|
55 A|
5 A|
E S
Individually monitored
Circuit monitored
Individually monitored
Regardless of circuit monitor-
ing or individual monitoring of
luminaires, individual emergency
and escape sign luminaires are
switched by potential-free inputs
or permanently used as main-
tained or non-maintained lumi-
naires. Built-in functions such as
staircase lighting or switching by
variable timers are available.
Emergency lighting as an
isolated solution
A standard built-in phase detec-
tor monitors the general power
supply system. If this power
supply fails, the DALI circuit in
question is short-circuited. All
DALI emergency and escape
sign luminaires change to sys-
tem-failure level and immediately
switch to the configured value.
This security function is exe-
cuted without communicating
with the emergency luminaires.
ONL I T E CENT RAL CPS 41
Phase detector
also monitors
LITENET netlink
Ethernet TCP/IP
Phase detector
DALI
to UVA (L/N)
E30
L
A
N

T
C
P
/
I
P
E30 Data
to UVA (L/N)
to UVA (L/N)
DALI
DALI
S
S
CPS-H CPS-BS
LITENET
netlink
LITENET
netlink
JJ A|
45 A|
55 A|
5 A|
8J A|
9J A|
!JJ A|
!2J A|
!J4 A|
!5J A|
S
CPS-U
E30
8 16 digital in
Phase detector loop
Individually monitored (DALI) combined
with LUXMATE LITENET
Temperature sensor
This system topology is based
on an ONLITE central CPS
with circuit-monitored mod-
ules (S). All luminaires (general
and emergency luminaires) are
metallically separated from one
or more common DALI chains
and networked to the LAN
hardware (Ethernet, TCP/IP) via
the LITENET netlink. All status
in formation is available via the
LUXMATE LITENET network.
The ONLITE central CPS oper-
ates completely independently,
and autonomously forwards
messages concerning bat-
tery and charger to LUXMATE
LITENET via the Ethernet net-
work.
Emergency lighting with
LUXMATE LITENET
System project planning
Step-by-step guide to the perfect lighting solution
The entire design process is
broken down into individual
design steps in order to ensure
a target-oriented approach
when designing emergency
lighting systems. This is a
tried-and-tested strategy for
arriving at the optimum solution.
Step 1 Do photometric calculations
for escape routes
Define Ballast Lumen
Factor (BLF)
percentage as basis
for output of each
emergency luminaire
Plan the locations
of escape sign luminaires
Define the circuits
in each fire compartment
Add up power output
(P
AC
and P
DC
)
of all emergency and escape
sign luminaires
for each output circuit
Determine
battery capacity
depending on duration
of battery-powered operation
Step 2
Step 3
Step 4
Step 5
Step 6
ONL I T E CENT RAL CPS 43
Light Wattage P AC [W] P DC [W] P DC [W] P DC [W] P DC [W] P DC [W] P DC [W] P DC [W] P DC [W] Control gear
Emergency lighting source at 230 V
level 5 % 10 % 15 % 20 % 30 % 40 % 50 % 70 %
LED 15.2 8.2 EM power2LED 1-sided
LED 22.7 13.3 EM power2LED 2-sided
T16 1/8 W 17.0 4.5 4.5 4.5 5.0 5.2 5.5 6.0 PC Board 8 W
T16 1/14 W 18.8 7.1 7.8 8.5 9.3 10.7 12.1 13.3 15.6 PCA excel one4all lp
T16 2/14 W 36.9 11.2 12.4 13.7 14.9 17.6 20.3 23.0 28.7 PCA excel one4all lp
T16 1/21 W 25.8 7.2 8.0 9.0 10.0 12.1 14.1 16.3 20.5 PCA excel one4all lp
T16 2/21 W 49.2 11.4 13.5 15.8 17.9 22.2 26.0 29.8 38.3 PCA excel one4all lp
T16 1/24 W 29.4 8.6 9.6 10.8 12.1 14.5 17.2 19.8 24.1 PCA excel one4all lp
T16 2/24 W 57.7 15.6 18.0 20.7 23.2 28.7 33.6 38.4 47.5 PCA excel one4all lp
T16 1/28 W 34.3 8.2 9.6 11.1 12.6 15.5 18.3 21.2 25.9 PCA excel one4all lp
T16 2/28 W 66.2 14.5 17.4 20.2 22.9 28.6 33.9 39.3 50.8 PCA excel one4all lp
T16 1/35 W 41.9 8.3 10.0 11.8 13.5 17.1 20.8 24.6 30.9 PCA excel one4all lp
T16 2/35 W 80.4 14.3 17.5 21.1 24.6 31.9 38.8 45.7 60.9 PCA excel one4all lp
T16 1/39 W 44.5 9.7 11.5 13.4 15.5 19.5 23.1 26.9 34.8 PCA excel one4all lp
T16 2/39 W 88.0 15.6 19.5 23.6 27.7 35.5 43.5 51.5 67.8 PCA excel one4all lp
T16 1/49 W 57.1 9.5 11.9 14.4 17.1 22.3 27.6 32.9 43.2 PCA excel one4all lp
T16 2/49 W 109.2 16.8 21.6 26.6 31.8 41.8 51.6 61.5 82.4 PCA excel one4all lp
T16 1/54 W 64.0 13.1 15.7 18.5 21.4 26.9 32.3 37.5 49.0 PCA excel one4all lp
T16 2/54 W 124.2 22.9 28.7 34.4 40.2 52.2 62.8 73.4 95.2 PCA excel one4all lp
T16 1/80 W 90.7 14.4 18.4 22.6 26.9 35.0 43.4 51.8 67.9 PCA excel one4all lp
T26 1/18 W 22.5 8.0 9.0 10.0 11.5 12.5 13.7 16.4 PCA excel one4all
T26 2/18 W 41.5 15.5 17.0 18.5 22.5 24.5 26.0 30.6 PCA excel one4all
T26 1/30 W 30.5 9.0 11.0 12.5 15.0 18.0 20.0 24.5 PCA excel one4all
T26 2/30 W 59.5 15.5 18.5 21.5 27.5 32.0 37.0 45.0 PCA excel one4all
T26 1/36 W 37.5 12.0 14.5 16.0 19.5 22.0 24.6 30.1 PCA excel one4all
T26 2/36 W 70.5 22.0 26.0 30.0 35.5 39.5 44.0 53.9 PCA excel one4all
T26 1/58 W 57.5 17.0 20.5 24.0 28.5 33.0 37.0 45.2 PCA excel one4all
T26 2/58 W 112.5 31.7 38.3 44.0 53.6 62.2 69.3 85.9 PCA excel one4all
TC-L/F 1/18 W 20.5 6.4 7.5 8.5 10.2 11.5 12.7 15.2 PCA excel one4all
TC-L/F 2/18 W 37.5 8.8 10.4 11.9 14.4 16.5 18.6 23.4 PCA excel one4all
TC-L/F 1/24 W 27.5 8.5 10.5 12.0 14.5 16.5 18.5 22.0 PCA excel one4all
TC-L/F 2/24 W 52.5 14.0 17.0 20.0 25.0 30.0 34.0 42.0 PCA excel one4all
TC-L/F 1/36 W 37.5 11.5 14.0 16.0 20.0 23.5 26.0 32.0 PCA excel one4all
TC-L/F 2/36 W 74.5 18.0 22.0 26.5 33.0 39.5 45.5 59.0 PCA excel one4all
TC-L/F 1/40 W 43.5 14.0 17.0 20.0 23.0 26.6 29.9 36.5 PCA excel one4all
TC-L/F 2/40 W 87.5 26.0 30.5 35.0 44.0 51.0 57.0 72.0 PCA excel one4all
TC-L/F 1/55 W 61.5 16.1 22.5 29.0 29.8 34.9 39.6 52.0 PCA excel one4all
TC-L/F 2/55 W 112.5 30.0 38.0 46.0 57.5 67.0 76.0 101.0 PCA excel one4all
TC-S/E 1/11 W 14.5 6.0 7.0 7.5 9.0 10.0 11.0 12.5 PCA excel one4all
TC-S/E 2/11 W 28.5 9.0 11.0 12.5 14.4 16.7 19.0 23.5 PCA excel one4all
TC-D/E 1/13 W 17.5 6.0 7.5 8.0 9.5 10.5 11.5 13.5 PCA excel one4all
TC-D/E 1/13 W 32.5 9.5 11.5 13.0 15.5 18.5 21.0 25.5 PCA excel one4all
TC-D/T 1/18 W 20.5 6.5 8.0 9.0 11.0 13.0 14.5 17.5 PCA excel one4all
TC-D/T 2/18 W 40.5 12.5 15.0 17.0 21.0 24.0 27.0 33.5 PCA excel one4all
TC-D/T 1/26 W 29.5 9.5 11.5 13.0 16.0 18.0 20.0 24.0 PCA excel one4all
TC-D/T 2/26 W 56.5 16.0 20.0 23.0 29.0 33.5 38.0 46.0 PCA excel one4all
TC-T/E 1/32 W 35.5 10.0 13.0 15.0 19.0 22.0 25.0 30.0 PCA excel one4all
TC-T/E 2/32 W 71.5 17.1 22.0 26.5 34.0 41.0 47.5 59.0 PCA excel one4all
TC-T/E 1/42 W 48.5 11.5 14.5 17.1 22.0 27.0 30.5 39.0 PCA excel one4all
TC-T/E 2/42 W 87.5 23.0 28.5 34.0 43.0 51.5 59.0 77.0 PCA excel one4all
Ballast/lumen factor
A
Power requirements of
CPS system
This table shows the maximum con-
nected loads of a system. To provide
for the permissible voltage drop of
cable dimensioning and to protect the
system, the actually calculated total
connected load must be used.
D
Total connected load [VA]
7000 14000 21000 30000
Switch-disconnector-fuse [A] 80 80 80 100
Single phase Two phase Three phase Three phase
DALI cable lengths
G
DALI control circuit cable length [m]
300 200 150 100
Recommended
Cu cross-section
with standard wiring [mm
2
] 1.5 1.0 0.8 0.5
Where possible, choose a standard
Cu cross-section of 1.5 mm
2
in order
to obtain optimum expansion.
System bus cable lengths
H
DATA bus cable length (m)
500 900
Line topology JY (St) Y 2 x 2 x 0.8
Free topology * JY (St) Y 2 x 2 x 0.8
* Free topology is recommended, sys-
tem bus need not be adapted for this
(see Page 37).
Power requirements
of ONLITE central
substation
(E00/E30)
E
Dimension cable appropriately
depending on distance and connect-
ing cable to ensure permissible volt-
age drop.
* Depending on cable length
Indicate = minimum cross-section
Total connected load [VA]
1000 2000 3000 3500 4000 4300
Fuse protection,
Neozed fuse [A] 16 16 20 20 25 25
Calculation for 50 m
Cable length * [mm
2
]

4 10 10 16 16 16
Calculation for 100 m
Cable length * [mm
2
]

6 16 25 25 35 35
ONLITE central CPS
outgoing circuits
Circuits are protected by 6.3 A fuses
suitable for DC on both poles. 3 A,
15 A or 10 A fuses can be used for
specific projects.
F
Output power [W]
435 870 1380
Fuse protection
Outgoing circuit [A] 3.15 6.30 10.00
Max. current carrying capacity [A] 1.90 3.80 6.00
Specify battery size
(OGiV block batteries)
B
Survey ventilation
conditions
C
Battery capacity [Ah]
C
10
at 1.8 V per cell
17 24 28 33 45 55 75 80 90 100 120 134 150 190 200
Required air volume flow rate
in case of artificial
ventilation [m
3
/h] 0.73 1.04 1.21 1.43 1.94 2.38 3.24 3.64 3.89 4.32 5.18 5.79 6.48 8.21 8.64
Cross-sectional area of
ventilation openings
with natural ventilation [cm
2
]

20.44 29.12 33.88 40.04 54.32 66.64 90.72 96.88 108.92 120.96 145.04 162.12 181.44 229.88 241.92
870
6.30
3.80
300
1.5
500

2 x 2 x 0.8
Standard equipment
Standard equipment
For optimum battery dimensioning, add 25 % reserve capacity
to these values (EN 50171 6.12.4).
Battery capacity [Ah]
25 C at 1.8 V per cell
17 24 28 33 45 55 75 80 90 100 120 150 190 200
Battery set DC output in W
216 V system 1 h 2,786 3,618 4,417 4,752 5,886 7,765 9,558 10,778 12,312 14,256 17,064 21,384 24,840 28,404
216 V system 3 h 1,075 1,415 1,782 2,030 2,549 3,262 4,180 4,644 5,119 6,145 7,171 8,888 10,638 12,528
216 V system 8 h 430 606 761 875 1,166 1,469 2,009 2,171 2,387 2,754 3,316 4,158 4,730 5,573
Data for ventilation of battery rooms according to EN 50272-2.
DALI
E30
E30
Data
Data
CPS-U
E30
CPS-K
DALI
E
E
CPS-U
E30
DALI
E
G
DALI cable lengths
Power and fuse protection
Individual monitoring
Individual monitoring
Individual monitoring
E
Connected loads
A
Ballast lumen factor
AC/DC power
See page 29 for
module versions
Battery selection
B
D Power and fuse protection
C
Outlet air and
volume of air
F
C
Inlet air and volume of air
ONL I T E CENT RAL CPS 45
System bus cable lengths
H
www.zumtobol.com/onlite
ONLITE ARTSIGN
ONLITE ARTSIGN EW, recessed into wall
Recessed wall luminaire with cover in
silver
Recessed housing made of extruded
aluminium section
Power LED (high-output version) lumi-
nance 200 cd/m
Chip on board LEDs (low-output ver-
sion) luminance approx. 70 cd/m
Central monitoring via Powerline, no
additional control line required
Escape signs must be ordered sepa-
rately
Voltage: central supply 220/240 V AC
and 220 V DC (central)
Cat. no. kg Order no.
With high-output central supply
ARTSIGN EW central NSI LED-HO 0.6 42 159 221
With low-output central supply
ARTSIGN EW central NSI LED-LO 0.6 42 159 222
High-output version EN 1838 and DIN 4844, low output EN 1838.
850C
incl. LED
ONLITE ARTSIGN EW escape sign
Escape sign
Panel made of diffuser pearl material
and screen-printed escape sign
according to direction
Cat. no. Order no.
Escape sign
ARTSIGN EW GK transparent for special pictogram 22 156 911
ARTSIGN EW RZ-1L single-sided pointing left 22 156 909
ARTSIGN EW RZ-1R single-sided pointing right 22 156 910
ARTSIGN EW RZ-1U single-sided pointing down 22 156 908
7
7
,
5
153 3
DIN 4844
200 cd/m
2
15m
EN1838
VMsc
ESCAPE SI GN L UMI NAI RES 46
ONLITE ARTSIGN
ONLITE ARTSIGN EW installation accessories
Required for installation in solid walls
or concrete walls
Prepared for tube installation
Housing made of sheet steel with
cover
Used for exposed concrete walls, but
also for subsequent plaster work
Cat. no. kg Order no.
Concrete casting surround
ARTSIGN EW GEH BETON 0.4 22 159 969
60
1
0
6
,
5
169
1
5
6
,
5
ONLITE LOOK ARTSIGN ED, recessed into ceiling
Luminaire recessed into ceiling, with
cover and escape sign
Recessed housing made of extruded
aluminium section
Cover (anti-glare frame) in silver with
acrylic glass panel and screen-prin-
ted escape sign according to direction
Power LED (high-output version) lumi-
nance 200 cd/m
Chip on board LEDs (low-output ver-
sion) luminance approx. 70 cd/m
Central monitoring via Powerline, no
additional control line required
Voltage: central supply 220/240 V AC
and 220 V DC (central)
Cat. no. kg Order no.
With high-output central supply
ARTSIGN ED central NSI LED-HO RZ-2S double-sided, sideways arrow* 0.3 42 159 223
ARTSIGN ED central NSI LED-HO RZ-2U double-sided, down arrow 0.3 42 159 224
With low-output central supply
ARTSIGN ED central NSI LED-LO RZ-2S double-sided, sideways arrow* V 0.3 42 159 225
ARTSIGN ED central NSI LED-LO RZ-2U double-sided, down arrow V 0.3 42 159 226
Low output EN 1838.
* Left or right can be chosen by rotating luminaire.
150,5
1
8
6
8
3
44 1
1
0
2
13
253
188
169 1
188
53
Cover
DIN 4844
200 cd/m
2
15m
EN1838
850C
incl. LED
ONLITE ARTSIGN ED installation accessories
Required for installation in concrete
ceilings
Prepared for tube installation
Housing made of sheet steel with
cover
Cat. no. kg Order no.
Concrete casting surround
ARTSIGN ED GEH BETON 0.5 22 159 968
182
1
1
4
93
44
Msc
ESCAPE SI GN L UMI NAI RES 47
ONLITE PURESIGN
ONLITE PURESIGN AW wall-mounted
W all-mounted LED luminaire
Flat metal housing
Extremely simple installation
Tool-free maintenance
Additional LED spot for escape route
lighting
Escape signs must be ordered sepa-
rately
Cat. no. kg Order no.
With central supply
PURESIGN AW central DALI 0.5 42 175 978
PURESIGN AW central NSI 0.5 42 175 977
Tested according to 60598-2-22 to DIN 4844/EN 1838 suitable for installations corresponding
to VDE 0108, VE EN2 and SEV. Escape signs with LED in aluminium frame to be ordered sepa-
rately.
306
11,5
38
1
5
6
ONLITE PURESIGN AW escape sign, 1-sided
Escape sign with LED in aluminium
frame
Anodised aluminium frame
Plastic diffuser printed with escape
route symbol
Escape sign symbol backlit by LEDs
LED spot for additional lighting of
escape door area
No tools required to fit to wall sur-
round
Luminance > 200 cd/m
Cat. no. kg Order no.
Escape sign
PURESIGN RZ-1L Single-sided, left arrow 0.8 22 157 779
PURESIGN RZ-1R Single-sided, right arrow 0.8 22 157 780
PURESIGN RZ-1U Single-sided, down arrow 0.8 22 157 781
Suitable according to DIN 4844 / EN 1838
306
11,5
38
1
5
6
DIN 4844
200 cd/m
2
30m
EN1838 incl. LED
ONLITE PURESIGN AW installation accessory
Installation accessory for wall-moun-
ted version
Ballproof rod guard made of galva-
nized steel
Three-point screw fastening
Cat. no. kg Order no.
Rod guard
ECOSIGN BWS Ballproof rod guard 1.1 22 157 531
400 85
2
9
0
ONLITE PURESIGN AD ceiling-mounted
Surface-mounted LED luminaire
Flush ceiling-mounted design with
shadow gap
Slim luminaire version
Standard mains terminals for
through-wiring
Extremely simple installation
Escape signs must be ordered sepa-
rately
Cat. no. kg Order no.
With central supply
PURESIGN AD central DALI LED 0.5 42 175 982
PURESIGN AD central NSI LED 0.5 42 175 981
Tested according to 60598-2-22 and DIN 4844/EN 1838 suitable for installations corresponding
to VDE 0108, VE EN2 and SEV. Escape signs with LED in aluminium frame to be ordered sepa-
rately.
306
171
55
18
1
5
6
sch
sch
ESCAPE SI GN L UMI NAI RES 48
ONLITE PURESIGN
ONLITE PURESIGN AD installation accessory
Installation accessory for 90 wall
mounting
Cable duct concealed in mounting
bracket
Cat. no. kg Order no.
Installation components
PURESIGN AW 90 0.2 22 157 785
10 16
250,5
1
4
0
1
6
ONLITE PURESIGN ASI cord suspension
LED surface-mounted luminaire, wire
suspension
1500 mm double cord suspension
with ceiling bracket
Continuous height adjustment
Extremely simple installation
Tool-free maintenance
Slim luminaire version
Standard mains terminals for
through-wiring
Escape signs must be ordered sepa-
rately
Cat. no. kg Order no.
With central supply
PURESIGN ASI central DALI LED 0.5 42 175 986
PURESIGN ASI central NSI LED 0.5 42 175 985
Tested according to 60598-2-22 to DIN 4844/EN 1838 suitable for installations corresponding
to VDE 0108, VE EN2 and SEV. Escape signs with LED in aluminium frame to be ordered sepa-
rately.
306
130
55
1
5
6
ONLITE PURESIGN TECTON
TECTON with ONLITE PURESIGN
Can be connected to TECTON conti-
nuous-row lighting system without
use of tools, luminaire rotates and
can be fixed through 90
Includes TECTON pendant suspension
(module length 300 mm)
Slim luminaire version
Tool-free maintenance
Escape signs must be ordered sepa-
rately
Cat. no. kg Order no.
With central supply
PURESIGN TEC central DALI LED 0.7 42 175 990
PURESIGN TEC central NSI LED 0.7 42 175 989
Tested according to 60598-2-22 to DIN 4844/EN 1838 suitable for installations corresponding
to VDE 0108, VE EN2 and SEV. Escape signs with LED in aluminium frame to be ordered sepa-
rately.
306
300
55
1
5
6
8
7
ONLITE PURESIGN emergency escape sign
Escape sign with LED in aluminium
frame
Anodised aluminium frame
Plastic diffuser printed with escape
route symbol
Escape sign symbol backlit by LEDs
No tools required to fit to device
holder
Luminance > 200 cd/m
Cat. no. kg Order no.
Two-sided
PURESIGN RZ-2S* pointing sideways 1.5 22 157 786
PURESIGN RZ-2U down arrow 1.5 22 157 787
One-sided
PURESIGN RZ-2L1 Single-sided, left arrow 1.5 22 157 906
PURESIGN RZ-2R1 Single-sided, right arrow 1.5 22 157 907
PURESIGN RZ-2U1 Single-sided, down arrow 1.5 22 157 908
* Left or right can be selected by rotating the escape sign. Delivered in pairs.
306
171
55
18
1
5
6
DIN 4844
200 cd/m
2
30m
EN1838 incl. LED
ESCAPE SI GN L UMI NAI RES 49
ONLITE COMSIGN
ONLITE COMSIGN ED, recessed into ceiling
Transparent disc/recessed luminaire
Housing made of polycarbonate
Please order escape signs with white
cover made of die-cast aluminium
separately
Assembly parts for recess of basic
housing into ceiling included in scope
of supply
Cat. no. kg Order no.
With central supply
COMSIGN ED central DALI 1/8 W 0.7 42 176 448
COMSIGN ED central NSI 1/8 W 0.7 42 173 839
Tested to 60598-2-22 and DIN 4844/EN 1838, suitable for installations according to VDE 0108,
VE EN2 and SEV.
T16
850C
incl. lamp
ONLITE COMSIGN ED escape sign/cover
Escape sign including cover
Acrylic glass panel with screen-prin-
ted escape route sign and cover
made of white painted die-cast alumi-
nium
Assembled as complete component
which is installed on basic housing
Cat. no. kg Order no.
Recessed version, two-sided
COMSIGN ED RZ-2S* pointing sideways 0.9 22 066 240
COMSIGN ED RZ-2U pointing downward 0.9 22 066 717
Recessed version, one-sided
COMSIGN ED RZ-1L pointing left 0.9 22 066 739
COMSIGN ED RZ-1R pointing right 0.9 22 066 745
COMSIGN ED RZ-1U pointing downward 0.9 22 066 723
* Choose left or right by turning luminaire.
360
260 16
79
1
5
2 2
,
5
Cover
DIN 4844
200 cd/m
2
26m
EN1838
ONLITE COMSIGN ED installation accessories
Required for installation in concrete
ceilings
Prepared for tube installation
Housing made of sheet steel with
cover
Cat. no. kg Order no.
Concrete casting surround
ECOSIGN/COMSIGN GEH BETON 1.3 22 066 751
357 72,5
164
1
2
0
sc
ESCAPE SI GN L UMI NAI RES 50
ONLITE COMSIGN
ONLITE COMSIGN AB, surface-mounted
sc
Transparent disc/surface-mounted
luminaire
Housing made of polycarbonate
Please order escape signs with white
cover made of die-cast aluminium
separately
Cat. no. kg Order no.
With central supply
COMSIGN AB central DALI 1/8 W 0.7 42 176 449
COMSIGN AB central NSI 1/8 W 0.7 42 159 228
Tested according to 60598-2-22 and DIN 4844/EN 1838, suitable for installations according to
VDE 0108, VE EN2 and SEV.
350
260
9
0
2
4
2
16
55
1
5
2 2
,
5
T16
850C
incl. lamp
ONLITE COMSIGN TECTON
sc
TECTON with ONLITE COMSIGN
Housing made of white polycarbonate
Includes TECTON pendant suspension
(module length 300 mm)
Can be connected to TECTON conti-
nuous-row lighting system without
use of tools, luminaire rotates and
can be fixed through 90
Please order escape signs with white
cover made of die-cast aluminium
separately
Cat. no. kg Order no.
With central supply
COMSIGN TECTON central DALI 1/8 W 1.1 42 176 450
COMSIGN TECTON central NSI 1/8 W 1.1 42 159 227
Tested according to 60598-2-22 and DIN 4844/EN 1838, suitable for installations according to
VDE 0108, VE EN2 and SEV.
350
260
3
2
7
8
2
300
1
7
6
9
3
T16
850C
incl. lamp
ONLITE COMSIGN AB/TECTON escape sign/cover
Escape sign including cover
Acrylic glass panel with screen-prin-
ted escape route sign and cover
made of white painted die-cast alumi-
nium
Assembled as complete component
which is installed on basic housing
Reduced lumen output in emergency
lighting: Central supply (central):
10 % to 100 %, separate battery
supply (NF1/NT1): 29 %, separate
battery supply (NF3/NT3): 22 %
Cat. no. kg Order no.
Surface-mounted version, two-sided
COMSIGN AB RZ-2S* pointing sideward 0.8 22 156 890
COMSIGN AB RZ-2U pointing downward 0.8 22 156 889
Surface-mounted version, one-sided
COMSIGN AB RZ-1L pointing left 0.8 22 156 892
COMSIGN AB RZ-1R pointing right 0.8 22 156 893
COMSIGN AB RZ-1U pointing downward 0.8 22 156 891
* Choose left or right by turning luminaire.
350
260 16
55
1
5
2 2
,
5
Cover
DIN 4844
200 cd/m
2
26m
EN1838
ESCAPE SI GN L UMI NAI RES 51
ONLITE ECOSIGN
ONLITE COMSIGN
ONLITE COMSIGN AB installation accessories
Installation accessories for surface-
mounted version
Optional installation accessories for
upgrading basic luminaire version
(ceiling-mounted)
Cat. no. kg Order no.
General installation accessories
COMSIGN API500 Pendant suspension 0.5 22 156 901
COMSIGN ASI1500 Cord suspension 0.3 22 156 902
COMSIGN AW 90 Plug-in sign wall 0.3 22 156 900
COMSIGN AW Wall-mounted 0.3 22 156 899
350
260
70
375
16
55 2
4
4
350
260
5
9
0
40
5
0
0
7
4
3
16
55
40
350
260
1
5
9
0
1
5
0
0
1
7
4
3
16
55 2
4
4
350
260 16
65
34
9
0
3
1
30 1
6
,
5
175
22 156 902 22 156 901 22 156 900 22 156 899
ONLITE ECOSIGN AB, surface-mounted
mscw
Ceiling-mounted luminaire
Housing made of white polycarbonate
with lateral metal clamps
Basic version can be mounted on cei-
ling without use of tools
Please order diffuser and escape
route signs separately
Cat. no. kg Order no.
With central supply
ECOSIGN AB central DALI 1/8 W 0.5 42 176 451
ECOSIGN AB central NSI 1/8 W 0.5 42 159 229
Tested according to 60598-2-22 and DIN 4844/EN 1838, suitable for installations according to
VDE 0108, VE EN2 and SEV.
335 55
2
3
8
T16
850C
incl. lamp
ONLITE ECOSIGN AB installation accessories
Installation accessories for surface-
mounted version
Installation accessories can be com-
bined with basic version as required
No additional accessories are
required for ceiling-mounting
Cat. no. kg Order no.
General installation accessories
ECOSIGN API500 Pendant suspension 0.5 22 156 878
ECOSIGN ASI1500 Cord suspension 0.2 22 156 879
ECOSIGN AW 90 Plug-in sign wall 0.3 22 156 877
ECOSIGN AW Wall-mounted 22 156 876
ECOSIGN BWS Ballproof rod guard 1.1 22 157 531
335 55
1
7
4
7
1
5
0
0
335
2
3
7
55
6,5
61,5
24
335
362
59
2
3
8
335
40
55
7
3
7
40
5
0
0
2
3
8
3
1
,
530
1
7
,
5
167,5
22 156 879 22 156 878 22 156 877 22 156 876
ESCAPE SI GN L UMI NAI RES 52
ONLITE ECOSIGN TECTON
sc
TECTON with ONLITE ECOSIGN
Housing made of white polycarbonate
with lateral metal clamps
Can be connected to TECTON conti-
nuous-row lighting system without
use of tools, luminaire rotates and
can be fixed through 90
Please order diffuser and escape
route signs separately
Cat. no. kg Order no.
Central supply, incl. suspension
ECOSIGN TECTON central DALI 1/8 W 0.8 42 176 452
ECOSIGN TECTON central NSI 1/8 W 0.8 42 159 230
Tested according to 60598-2-22 and DIN 4844/EN 1838, suitable for installations according to
VDE 0108, VE EN2 and SEV.
335
3
0
6
7
0
300
2
3
8
T16
850C
incl. lamp
ONLITE ERGOSIGN
ONLITE ERGOSIGN AB, surface-mounted ch
Escape sign luminaire
Housing made of die-cast aluminium,
white powder-coated
Cables can be fed through base of
housing
Suitable for wall or ceiling installation
Diffuser made of opalised plastic
Luminaire comprises base housing
and electronic circuitry, cover and
6 pictograms (arrow pointing left,
right, downwards; recognition dis-
tance: 15 m for deep version, 8 m for
shallow version)
Cat. no. kg Order no.
With central supply
ERGOSIGN AB central DALI 1/8 W 1.2 42 174 819
ERGOSIGN AB central NSI 1/8 W 1.2 42 174 718
Tested according to 60598-2-22 and DIN 4844/EN 1838, suitable for installations according to
VDE 0108, VE EN2 and SEV.
280
356,5
115
4
8
8
5
87,5
8
7
,
5
T16
DIN 4844
200 cd/m
2
15m
EN1838
850C
incl. lamp
ESCAPE SI GN L UMI NAI RES 53
ONLITE ECOSIGN AB/TECTON escape sign/cover
Diffuser with escape sign
Polycarbonate opal cover with additi-
onal downwards light outlet, internal
longitudinal prisms providing support
illumination of escape route
Emergency escape sign with screen-
printed cover
Tool-free installation on base housing
Tool-free re-lamping possible
Cat. no. kg Order no.
Surface-mounted version, two-sided
ECOSIGN RZ-2S* pointing sideward 0.7 22 156 871
ECOSIGN RZ-2U pointing downward 0.7 22 156 870
Surface-mounted version, one-sided
ECOSIGN RZ-1L pointing left 0.7 22 156 873
ECOSIGN RZ-1R pointing right 0.7 22 156 874
ECOSIGN RZ-1U pointing downward 0.7 22 156 872
* Left or right can be chosen by turning cover.
DIN 4844
200 cd/m
2
32m
EN1838
ONLITE ECOSIGN
Cover
335 55
1
6
5
ONLITE ECOSIGN
ONLITE ECOSIGN Safety AB, surface-mounted
mscw
Emergency luminaire
Housing made of white polycarbonate
with lateral metal clamps
Basic version can be mounted on cei-
ling without use of tools
Please order diffuser separately
Cat. no. kg Order no.
With central supply
ECOSIGN AB central DALI 1/8 W 0.5 42 176 451
ECOSIGN AB central NSI 1/8 W 0.5 42 159 229
Tested according to 60598-2-22 and DIN 4844/EN 1838, suitable for installations according to
VDE 0108, VE EN2 and SEV.
335 55
1
0
9
T16 incl. lamp
EMERGENCY L UMI NAI RES 54
ONLITE CUBESIGN
ONLITE CUBESIGN AB, surface-mounted ch
Escape sign luminaire
Cube-shaped luminaire made of opal
plastic with metal base
Escape sign screen-printed onto plas-
tic panel
Project-specific pictograms available
acc. to consultation
Installed using cord suspension (not
included with luminaire)
Length of cord suspension continuo-
usly adjustable up to 5 m
Cat. no. kg Order no.
With central supply
CUBESIGN AB central DALI TC-DEL 1/26 W 42 176 454
CUBESIGN AB central NSI 1/26 W TC-DEL 7.5 42 174 178
Cord suspension
CUBESIGN ASI5000 22 161 509
Tested according to 60598-2-22 and DIN 4844/EN 1838, suitable for installations according to
VDE 0108, VE EN2 and SEV.
500
5
0
0
400
4
0
0
TC-DEL
DIN 4844
200 cd/m
2
90m
EN1838 incl. lamp
ONLITE PROOFSIGN
ONLITE PROOFSIGN AB, surface-mounted mc
Escape sign luminaire
Recognition range: 16 m (EN 1838)
Highest protection requirements
(IP 65)
Housing and cover ring made of poly-
carbonate
Installation: 2 V2A catches (stainless)
With T16/8 W fluorescent lamp
3 pictograms are supplied (arrow left,
arrow right, arrow down)
Momentary-action test switch inte-
grated
Cat. no. kg Order no.
With central supply
PROOFSIGN AB central NSI 1/8 W 0.9 42 159 232
Tested according to 60598-2-22 and DIN 4844/EN 1838, suitable for installations according to
VDE 0108, VE EN2 and SEV.
T16
DIN 4844
200 cd/m
2
16m
EN1838
850C
incl. lamp
3
2
70
664
152 360
112
1
2
0
116
ONLITE ECOSIGN Safety TECTON
sc
TECTON with ONLITE ECOSIGN Safety
Housing made of white polycarbonate
with lateral metal clamps
Please order diffuser separately
Can be connected to TECTON conti-
nuous-row lighting system without
use of tools, luminaire rotates and
can be fixed through 90
Cat. no. kg Order no.
Central supply, incl. suspension
ECOSIGN TECTON central DALI 1/8 W 0.8 42 176 452
ECOSIGN TECTON central NSI 1/8 W 0.8 42 159 230
Tested according to 60598-2-22 and DIN 4844/EN 1838, suitable for installations according to
VDE 0108, VE EN2 and SEV.
335
1
7
7 1
0
0
300
7
7
T16 incl. lamp
ONLITE ECOSIGN
ONLITE ECOSIGN Safety AB/TECTON cover
Diffuser for emergency and escape
route lighting
Diffuser made of clear polycarbonate
with longitudinal prisms and special
reflector for emergency and escape
route lighting
Can be fitted on basic housing
without use of tools
Reduced lumen output in emergency
lighting: Central supply (central):
10 % to 100 %, separate battery
supply (NF1/NT1): 29 %, separate
battery supply (NF3/NT3): 22 %
Cat. no. kg Order no.
Diffuser for emergency and escape route lighting
ECOSIGN ABD RW AB clear diffuser 0.2 22 156 875
335 55
3
5
Calculation in 100% light current.
Mounting height
(m)
Mounting height
(m)
Measuring plane 0,02m
2.2
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
L 1
(m)
4.5
4.2
5.4
5.5
5.6
5.7
L 2
(m)
10.2
10.4
11.2
11.4
11.8
12.2
L 3
(m)
1
1
1
1.5
1.5
1.5
L 4
(m)
5.8
6
7.1
7.2
7.3
7.4
L 1 L 2
35.8 m
1
6
.
8

m
L 3
L 4
E
min
= 1.25 lx
2.2
2.5
3.0
3.5
4.0
4.5
5.5
6.0
L 1
(m)
4.6
4.8
5.8
5.0
4.5
3.5
L 2
(m)
11.5
11.9
11.7
13.1
13.5
13.8
13.0
12.0
L 1 L 2
35 m
H

1
L 2
Measuring plane 0,02 m
E
min
= 1.25 lx
EMERGENCY L UMI NAI RES 55
ONLITE ECOSIGN
ONLITE ECOSIGN Safety EB, recessed
mswc
Emergency luminaire
Housing made of white polycarbonate
with lateral metal clamps
Cover made of transparent polycarbo-
nate with longitudinal prisms and
highly specular reflector (can be fitted
onto basic housing without use of any
tools), included in scope of supply
Mounting frame for fixing on wall or
ceiling
Cat. no. kg Order no.
With central supply
ECOSIGN EB central DALI 1/8 W 42 176 453
ECOSIGN safety EB central NSI 1/8 W 0.6 42 159 233
Tested according to 60598-2-22 and DIN 4844/EN 1838, suitable for installations according to
VDE 0108, VE EN2 and SEV.
364
335 84
55
350 1
68 1
7
2
3
5
1
,
5
T16 incl. lamp
ONLITE ECOSIGN Safety installation accessories EB, recessed
Required for installation in solid walls
or concrete ceilings
Remember desired direction of light
when fitting
Prepared for tube installation
Housing made of sheet steel with
cover
For use in exposed concrete walls/
ceilings, but also if subsequently
plastered
Cat. no. kg Order no.
Concrete casting surround
ECOSIGN/COMSIGN GEH BETON 1.3 22 066 751
357 72,5
164
1
2
0
EMERGENCY L UMI NAI RES 56
55
1
0
9
335
25
362
335
1
6
1
8
55
1
5
0
0
335
40
6
0
8
55
5
0
0
40
7
55
1
0
9
62
335
1
0
9
ONLITE ECOSIGN Safety installation accessories AB, surface-mounted
Installation accessories for surface-
mounted version
Installation accessories can be com-
bined with basic version as required
No additional accessories are
required for ceiling-mounting
Cat. no. kg Order no.
General installation accessories
ECOSIGN API500 Pendant suspension 0.5 22 156 878
ECOSIGN ASI1500 Cord suspension 0.2 22 156 879
ECOSIGN AW 90 Plug-in sign wall 0.3 22 156 877
ECOSIGN AW Wall-mounted 22 156 876
ONLITE CENTRAL LPS
System application
PLC relay
PLC interface
Circuit 1
Tecton
PLC interface Tecton
Energy-saving lamp
Escape sign luminaire
Momentary-action switch
Momentary-action switch
L1 Circuit 2
Circuit 3
Connection to lighting management system
Staircase
lighting function
Sub-distribution board
EPS 360
EPD
ONLITE SECTION CENTRAL 360
Low power system
Central supply and monitoring of
emergency and escape sign lumin-
aires/version central
Individual monitoring of luminaires
Test log book function > 3 years
3 output circuits each for a max. of
20 luminaires
Backlit touch panel for control/pro-
gramming and visualisation
Charging unit for lead-gel batteries
incl. temperature display
Power line communication to lumin-
aires
Housing sheet-steel cabinet incl. bat-
tery compartment
All cable outputs have been prewired
on a terminal strip
Set of batteries included in the supply
inc. interface box
Voltage: 230 V +/ 10 %, frequency:
50/60 Hz Output voltage: 230 V AC
(mains operation), 230 V DC (emer-
gency operation)
Section Central 360: Max. installed
load: 2.4 kW (at full load) Output of
circuits: Circuits 13: 660 W AC (4AT)
120 W DC max. 160 W DC each
Cat. no. L/W/H Order no.
Section central 360
360 W 1 h 05 JB 28 Ah 2x12 V Housing model: 02 500/202/800 22 156 814
360 W 1 h 10 JB 32 Ah 2x12 V Housing model: 02 500/202/800 22 156 815
360 W 1 h 10 JB 35 Ah 2x12 V Housing model: 01 460/130/1260 22 156 818
360 W 3 h 10 JB 61 Ah 2x12 V Housing model: 01 460/130/1260 22 156 819
360 W 3 h 10 JB 61 Ah 2x12 V Housing model: 03 600/202/1000 22 156 817
Section Central 360 Nport2 Ethernet Version
360 W 1 h 05 JB 28 Ah 2x12 V Housing model: 02 500/202/800 22 154 542
360 W 1 h 10 JB 32 Ah 2x12 V Housing model: 02 500/202/800 22 154 543
360 W 1 h 10 JB 35 Ah 2x12 V Housing model: 01 460/130/1260 22 154 545
360 W 3 h 10 JB 61 Ah 2x12 V Housing model: 01 460/130/1260 22 154 546
360 W 3 h 10 JB 61 Ah 2x12 V Housing model: 03 600/202/1000 22 154 544
500
8
0
0
420
7
2
0
125
Typ 2
9 mm
2
0
2
600
1
0
0
0
520
9
2
0
125
Typ 3
9 mm
2
0
2
460
1
2
6
0
125
Typ 1
1
3
0
SUPPLY AND MONI T ORI NG MODUL ES 57
ONLITE CENTRAL LPS
ONLITE SECTION CENTRAL 720 / 1080 / 1440
Low power system
Central supply and monitoring of
emergency and escape sign lumin-
aires/version central
Individual monitoring of luminaires
Test log book function > 3 years
3 output circuits each for a max. of
20 luminaires
Backlit touch panel for control/pro-
gramming and visualisation
Charging unit for lead-gel batteries
incl. temperature display
Power line communication to lumin-
aires
Housing sheet-steel cabinet incl. bat-
tery compartment
All cable outputs have been prewired
on a terminal strip
Set of batteries included in the supply
inc. interface box
Voltage: 230 V +/ 10 %, frequency:
50/60 Hz Output voltage: 230 V AC
(mains operation), 230 V DC (emer-
gency operation)
Section Central 720: Max. installed
load: 4.7 kW (at full load) Output of
circuits: Circuits 16: 660 W AC (4AT)
120 W DC max. 160 W DC each
Section Central 1080: Max. installed
load: 7.0 kW (at full load) Output of
circuits: circuits 19: each 660 W AC
(4AT) 120 W DC max. 160 W DC
Section Central 1440: Max. installed
load: 9.5 kW (at full load) Output of
circuits: circuits 112: each 660 W
AC (4AT) 120 W DC max. 160 W DC
Cat. no. Order no.
Section central 720
720 W 1 h 05 JB 28 Ah 4x12 V Housing model: 03 22 156 820
720 W 1 h 10 JB 32 Ah 4x12 V Housing model: 03 22 156 821
720 W 3 h 10 JB 61 Ah 4x12 V Housing model: 03 22 156 822
Section Central 720 Nport2 Ethernet Version
720 W 1 h 05 JB 28 Ah 4x12 V Housing model: 03 22 154 547
720 W 1 h 10 JB 32 Ah 4x12 V Housing model: 03 22 154 548
720 W 3 h 10 JB 61 Ah 4x12 V Housing model: 03 22 154 549
Section central 1080
1080 W 1 h 05 JB 28 Ah 6x12 V Housing model: 04 22 156 823
1080 W 1 h 10 JB 32 Ah 6x12 V Housing model: 04 22 156 824
1080 W 3 h 10 JB 61 Ah 6x12 V Housing model: 04 22 156 825
Section Central 1080 Nport4 Ethernet Version
1080 W 1 h 05 JB 28 Ah 6x12 V Housing model: 04 22 154 550
1080 W 1 h 10 JB 32 Ah 6x12 V Housing model: 04 22 154 551
1080 W 3 h 10 JB 61 Ah 6x12 V Housing model: 04 22 154 552
Section central 1440
1440 W 1 h 05 JB 28 Ah 8x12 V Housing model: 04 22 156 826
1440 W 1 h 10 JB 32 Ah 8x12 V Housing model: 04 22 156 827
1440 W 3 h 10 JB 61 Ah 8x12 V Housing model: 04 22 156 828
Section Central 1440 Nport4 Ethernet Version
1440 W 1 h 05 JB 28 Ah 8x12 V Housing model: 04 22 154 553
1440 W 1 h 10 JB 32 Ah 8x12 V Housing model: 04 22 154 554
1440 W 3 h 10 JB 61 Ah 8x12 V Housing model: 04 22 154 555
ONLITE CENTRAL PHASE DETECTOR
Phase detector
Three-circuit monitoring module
installed in switch cabinet, for fixing
on rail
Checks three-phase network for
undervoltage and phase failure; inter-
ruption of neutral conductor is also
detected
3 LEDs for status display (mains vol-
tage applied)
2 change-over contacts
Voltage range: 230 V AC, max. vol-
tage of outer conductor: 450 V AC
Wattage: 15 W Switching contact:
125 V AC/DC, 2 A (60 W) Monitoring
window: Unetz 0.60.85 Unenn
Cat. no. L/W/H DB Modules Order no.

ONLITE central EPD 35/90/59 2 22 156 808
Suitable for use in installations acc. to VDE 0108.
9
0
3
5
35 59
SUPPLY AND MONI T ORI NG MODUL ES 58
600
1
0
0
0
520
9
2
0
125
Typ 3
9 mm
2
0
2
900
1
5
9
0
720
1
4
8
0
125
Typ 4
9 mm 30 mm
40
2
0
2
ONLITE CENTRAL LPS
ONLITE CENTRAL POWER SUPPLY
Power supply
Power: voltage 24 V AC, current
350 mA
Power supply module for Section cen-
tral GSM
Switch-cabinet module
Cat. no. L/W/H DB Modules Order no.

ONLITE Power Supply 35/90/59 2 22 156 809
9
0
3
5
35 59
ONLITE CENTRAL GSM MODULES
GSM module
Module for dialling into a GSM net-
work
Incl. antenna, without SIM card
Programming possible via mobile
phone
Before programming, the program-
ming mode of the controller must be
enabled
SMS fault messages
Switch-cabinet module
Cat. no. L/W/H DB Modules Order no.

ONLITE GSM Module 105/90/59 6 22 156 810
9
0
3
5
105 59
ONLITE CENTRAL PRINTER
Infrared printer
For printing out test logs
Insensitive to interferences and short
interruptions of infrared connection
Sturdy, fixed thermo-print line
Battery pack and mains unit included
in scope of supply
Inc. 4 reels of thermopaper
Cat. no. Order no.

ONLITE IR-Printer 22 154 522
9
0
4
6
7
6
160
ONLITE CENTRAL REMOTE INTERFACE
Remote indication
Remote indication of system status
via LEDs
Emergency lighting installation blo-
cked using lockswitch
Connection to the floating signalling
contact of the central section
External power supply required (e.g.
ONLITE power supply)
Max. 24 V AC/DC, max. 2 A
Cat. no. Order no.

ONLITE central Remote Interface 22 161 513
Accessory
ONLITE Power Supply 22 156 809
8
0
3
2
95
SUPPLY AND MONI T ORI NG MODUL ES 59
ONLITE CENTRAL LPS
ONLITE CENTRAL INTERFACE FOR LUMINAIRES
Interface for emergency luminaires
PLC-DALI module converts the Pow-
erline signal into a DALI signal
Lamp faults are reported back to the
emergency power supply (section
central)
20 physically adjustable addresses
With integrated L switching input
Switching and dimming without addi-
tional control line
SET DC function via PLC to electronic
ballast (emergency lighting level can
be adjusted in electronic ballast)
The cable from the emergency power
supply to the PLC may have a max.
length of 300 m
Luminaire installation module (max.
distance between module and lumin-
aire is 10 m)
Input voltage: 230 V AC/230 V DC
Wattage: AC mode < 2 W (without
load), DC mode < 0.5 W (without
load)
Cat. no. L/W/H Order no.

ONLITE central PLC DALI Interface 160/30/21 22 156 804
160
149
4,5
21
3
0
Luminaire address Address switch 1 Address switch 2
1 0 1
2 0 2
3 0 3
. . .
.. .. ..
10 0 10
11 10 1
12 10 2
. . .
.. .. ..
20 10 10
Address
switch 1
Address
switch 2
0
2
6
7
1
3
4
5
8
9
+ 0
+10
Powerline in
L'
L
N
230 V~ 50Hz
1
0
1
2 3 4
5
6
789
ONLITE
PLC-DALI
Dali bus
up to 20 luminaires per circuit
ONLITE
PLC-DALI
Mains/Netz
Failure/Strung
ZUMTOBEL STAFF
DAS LICHT
SEPS 360

Fuse / Sicherung
L N PE
O3 O2 U3 U2 O1 U1
S1 S2 D1 D2 Rx Gnd Tx + _
12 14 T1 11 T3 P1 P2 Relais 1 22 24 21 Relais 2 32 34 31 Relais 3 T2
230 V/AC/DC power supply
PLC Powerline
communcation
230 V AC/DC
Dali bus
230 V AC/DC
EVG
DALI
Mains
EVG
DALI
Mains
ONLITE CENTRAL RELAY FOR LUMINAIRES
Relay for emergency luminaires
PLC relay module switches AC/DC-
compatible consumers via the Power-
line signal
Lamp faults are reported back to the
emergency power supply (section
central)
20 physically adjustable addresses
With integrated L switching input
Switching without additional control
line
The cable from the emergency power
supply to the PLC may have a max.
length of 300 m
Luminaire installation module
Input voltage: 230 V AC/230 V DC
Wattage: AC mode < 2 W (without
load), DC mode < 0.5 W (without
load)
Cat. no. L/W/H Order no.

ONLITE central PLC Relais 190/30/28 22 156 805
190
180
4,5
28
3
0
Luminaire address Address switch 1 Address switch 2
1 0 1
2 0 2
3 0 3
. . .
.. .. ..
10 0 10
11 10 1
12 10 2
. . .
.. .. ..
20 10 10
Address
switch 1
Address
switch 2
0
2
6
7
1
3
4
5
8
9
+ 0
+10
Powerline in
L'
L
N
230 V~ 50Hz
1
0
1
2 3 4
5
6
789
Mains/Netz
Failure/Strung
ZUMTOBEL STAFF
DAS LICHT
SEPS 360

Fuse / Sicherung
L N PE
O3 O2 U3 U2 O1 U1
S1 S2 D1 D2 Rx Gnd Tx + _
12 14 T1 11 T3 P1 P2 Relais 1 22 24 21 Relais 2 32 34 31 Relais 3 T2
230 V/AC/DC power supply
PLC Powerline
communcation
230 V AC/DC
230 V AC/DC
up to 20 luminaires per circuit
ONLITE
PLC-Relay
ONLITE
PLC-Relay
SUPPLY AND MONI T ORI NG MODUL ES 60
ONLITE CENTRAL LPS
ONLITE CENTRAL ELECTRONIC BALLAST FOR LUMINAIRES
Electronic ballasts
PLC electronic ballast module for
operating one T5 8 W fluorescent
lamp
Lamp faults are reported back to the
emergency power supply (section
central)
20 physically adjustable addresses
Switching and dimming without addi-
tional control line
The cable from the emergency power
supply to the PLC may have a max.
length of 300 m
Input voltage: 230 V AC/230 V DC
Power input: AC operation < 11 VA
Luminaire installation module
Cat. no. Order no.

ONLITE central PLC EVG 8 W 22 156 799
230
219
28
3
0
ONLITE GO-ON package F
ONLITE graphical user interface
Visualisation package for graphic dis-
play and monitoring of up to 500
emergency or escape sign luminaires
Rail-mounted PC with external
230 V/24 V power pack
Mouse, German keyboard and Y-plug
Visualisation software with single
user licence enabled
Pre-defined GO plan files for Section
Central 360, 720, 1080, 1440 and
SB 128 Controller
Commissioning/configuration of a
Section Central or an SB 128 CTP
Controller
Caption for up to 60 emergency or
escape sign luminaires
Cat. no. Order no.

GO-ON package ONLITE visualisation computer 22 154 418
Standard travel allowances are not included.
1
0
7
166 60
189
GO-ON GO
GO
RS-232 RS-232 RS-232 RS-232 RS-232 RS-232
RS-232 RS-232
HUB
TCP/IP TCP/IP
Nport4 Nport2
24V/GND
DC-IN
VGA MS/KB COM2 COM1
LAN1 LAN2
RS-232 RS-232 RS-232 RS-232
EPS 360 EPS 360 EPS 360 EPS 360
SB 128 SB 128
Client PC
AN TCP IP
RJ 45 crossed network cable
Extension line RS-232
(uncrossed) max. 2 m
SUPPLY AND MONI T ORI NG MODUL ES 61
ONLITE CENTRAL CPS
ONLITE central CPS
Safety ensured by modular
large-size unit
Central battery system
The progress of ONLITE emergency
lighting systems is based on the
worldwide unique strategy of using
any DALI luminaire as an emergency
luminaire, monitoring it and supplying
it with emergency power in case of an
emergency. Maintenance work is done
fully automatically, faults are displayed
clearly.
Especially for projects involving more
than 100 emergency luminaires: The
new CPS Central Power System with
mobile monitoring and programming
unit, which comes as a touch-sensitive
panel with colour display, Ethernet and
Web browser link, USB port and multi-
media card, relying on state-of-the-art
technology as well as maximum con-
venience, easy operation and flexibility.
www.zumtobel.com/onlite
ONLITE central CPS
SUPPLY AND MONI T ORI NG MODUL ES 62
ONLITE CENTRAL CPS
ONLITE CENTRAL CPS K
CPS compact station
Central battery system in compact
cabinet
7" VGA Touch PC for operating and
visualising the installation
Ethernet connection for web-browser
based system-networking and visuali-
zation
Fully automatic execution of tests and
documentation in electronic test book
USB/MMC or SD for test book archi-
ving
2 x 020 circuits, with monitoring of
individual luminaires or circuit, also
mixed monitoring mode in units of 20
Max. 20 luminaires per circuit
Power per circuit (AC/DC): 1300 W
In single-luminiaire monitoring mode,
each DALI luminaire can be controlled
and monitored individually. Mixed
operation possible within one circuit.
All line outlets are pre-wired to termi-
nal strips
Sheet steel housing in powder-coated
RAL 7035 finish
Available models:
Left/right door hinge
E30 version possible
Power increase up to 30 kVA
06 outlets for substations
OGI monobloc batteries 216 V,
1775 Ah in combi-cabinet mit tem-
perature-controlled U/I charging
Cat. no. Order no.

ONLITE Central CPS K 22 154 689
ONLITE CENTRAL CPS U
CPS sub-cabinet
Sub-distribution system for emer-
gency lighting housed in sheet-steel
cabinet in powder-coated RAL 7035
finish
120 circuits, monitoring of individual
luminaires or circuit
Max. 20 luminaires per circuit
Power per circuit (AC/DC): 1300 W
In single-luminiaire monitoring mode,
each DALI luminaire can be controlled
and monitored individually. Mixed
operation possible within one circuit.
All line outlets are pre-wired to termi-
nal strips
Available models:
Left/right door hinge
E30 version possible
Cat. no. Order no.

ONLITE Central CPS U E00 22 154 691
ONLITE Central CPS U E30 22 154 692
SUPPLY AND MONI T ORI NG MODUL ES 63
8
0
0
1
3
7
6
334 374
300 140
CPS U E00 CPS U E30
1
8
0
0
600 850
CPS K
ONLITE CENTRAL CPS
ONLITE CENTRAL CPS H
CPS main station
Central battery facility housed in
sheet steel cabinet in powder-coated
RAL 7035 finish
7" VGA Touch PC for operating and
visualising the installation
Ethernet connection for web-browser
based system-networking and visuali-
zation
Fully automatic execution of tests and
documentation in electronic test book
USB/MMC or SD for test book archi-
ving
3 x 020 circuits, with monitoring of
individual luminaires or circuit, also
mixed monitoring mode in units of 20
Max. 20 luminaires per circuit
Power per circuit (AC/DC): 1300 W
In single-luminiaire monitoring mode,
each DALI luminaire can be controlled
and monitored individually. Mixed
operation possible within one circuit.
All line outlets are pre-wired to termi-
nal strips
Please order batteries separately for
fitting in external battery box or on
battery rack
Available models:
Left/right door hinge
E30 version possible
Power increase up to 30 kVA
06 outlets for substations
Cat. no. Order no.

ONLITE Central CPS H 22 154 690
ONLITE CENTRAL CPS BS
CPS battery cabinet
Sheet-steel battery cabinet in pow-
der-coated RAL 7035 finish with
compartment trays for batteries
Electrolyte capture tray built into base
of cabinet
OGI monobloc batteries 216 V,
33200 Ah
Temperature sensor can be installed
in battery cabinet
Connecting leads included with batte-
ries
Available models:
Left/right door hinge
Cat. no. Order no.

ONLITE Central CPS BS 22 154 693
Battery cabinets E00 HxWxD (mm) Weight (kg)

33 Ah 1600x600x600 211
45 Ah 1600x600x600 267
55 Ah 1600x600x600 324
75 Ah 1600x600x600 432
80 Ah 1800x850x600 472
90 Ah 1800x850x600 540
100 Ah 1800x850x600 540
120 Ah 1800x950x600 679
134 Ah 1800x850x600 765
150 Ah 1800x1100x600 836
190 Ah (2 cabinets) 1800x1100x600 + 1800x600x600 1167
200 Ah (2 cabinets) 1800x1100x600 + 1800x600x600 1206
SUPPLY AND MONI T ORI NG MODUL ES 64
1
8
0
0
600 850
CPS H E00 R
max. 40 circuits
CPS H E00 R
max. 60 circuits
SUPPLY AND MONI T ORI NG MODUL ES 65
ONLITE CENTRAL CPS BG
PE sinter-coated, fully insulated, acid-
resistant longitudinal and transverse
supports
Withstand voltage to DIN VDE 0100
and DIN VDE 0510 TV
Simple grounding facility
Height-adjustable feet made of insu-
lating plastic
Quick, easy and clean to install
Cat. no. Order no.

ONLITE Central CPS BG 22 154 694
L
H
B
B
33Ah 211 54 600 715 1246
45Ah 267 54 600 715 1244
55Ah 324 54 600 715 1284
75Ah 432 54 600 715 1289
80Ah 472 59 750 715 1074
90Ah 540 59 750 715 1074
100Ah 540 59 750 715 1074
120Ah 679 68 900 715 1074
134Ah 765 59 750 715 1074
150Ah 836 83 1050 715 1074
190Ah 1167 85 1200 930 1074
200Ah 1206 85 1200 930 1074
Battery
holder)
Weight (kg)
of battery
holder
Weight (kg)
of battery
rack
Length L Width W Height
above the
battery HB
ONLITE CENTRAL CPS
ONLITE CENTRAL monobloc battery
OGiV high-rate pasted plates (lead/
calcium)
Absorbent glass mat technology
17200 Ah capacity in 12 V monob-
locs
ABS case and lid
recessed threaded bras post termi-
nals
DIN EN 60896-2:1997 compliant
extremely low gas
low self-discharge
100 % recyclable
Units are maintenance free
Cat. no. Connection L/W/H Order no.
10-year monobloc battery
Accu Pb/10 12 V 17 Ah M5 181/77/167 22 154 695
Accu Pb/10 12 V 24 Ah M5 166/175/125 22 154 696
Accu Pb/10 12 V 28 Ah M5 165/125/175 22 154 697
Accu Pb/10 12 V 33 Ah M6 195/130/168 22 154 698
Accu Pb/10 12 V 45 Ah M6 197/165/170 22 154 699
Accu Pb/10 12 V 55 Ah M6 239/132/210 22 154 700
Accu Pb/10 12 V 75 Ah M6 258/166/215 22 154 702
Accu Pb/10 12 V 80 Ah M6 350/167/179 22 154 703
Accu Pb/10 12 V 90 Ah M6 306/169/214 22 154 704
Accu Pb/10 12 V 100 Ah M6 330/171/222 22 154 705
Accu Pb/10 12 V 120 Ah M8 410/176/277 22 154 706
Accu Pb/10 12 V 134 Ah M8 342/172/277 22 154 707
Accu Pb/10 12 V 150 Ah M8 485/172/240 22 154 708
Accu Pb/10 12 V 190 Ah M8 522/238/218 22 154 709
Accu Pb/10 12 V 200 Ah M8 522/238/223 22 154 710
Zumtobel is the internationally leading
supplier of integral lighting solutions for
a wide variety of applications in profes-
sional interior lighting:
Industry and engineering
Offices and communication
Education and science
Presentation and retail
Hospitality and wellness
Art and culture
Health and care
Sport and leisure
Transit areas and car parks
Orientation and safety
We provide unique customer benefit
by integrating technology, design,
emotion and energy efficiency. Under
the Humanergy Balance concept, we
combine the best possible ergonomic
lighting quality for peoples well-being
with the responsible use of energy
resources.
The companys own sales organisa-
tions in twenty countries as well as
commercial agencies in fifty other
countries form an international network
of experts and design partners provi-
ding professional lighting consulting,
design assistance and comprehensive
services.
Corporate goal: We want to use
light to create worlds of experience,
make work easier and improve com-
munications and safety while remaining
fully aware of our responsibility to the
environment.
P R E S E N TAT I O N
A N D R E TA I L
A R T
A N D C U LT U R E
H O S P I TA L I T Y
A N D WE L L N E S S
S P O R T
A N D L E I S U R E
H E A LT H
A N D C A R E
T R A N S I T A R E A S
A N D C A R PA R K S
O F F I C E S
A N D C O MMU N I C AT I O N
I N D U S T RY
A N D E N G I N E E R I N G
United Kingdom
Zumtobel Lighting Ltd.
Unit 4 - The Argent Centre,
Pump Lane
London
Hayes/Middlesex UB3 3BL
T +44/(0)20 8589 1800
F +44/(0)20 8756 4800
M enquiriesuk@zumtobel.com
www.zumtobel.co.uk
USA and Canada
Zumtobel Lighting Inc.
Location Highland
3300 Route 9W
Highland, New York 1258-2630
T +1/(0)845/691 62 62
F +1/(0)845/691 62 89
www.zumtobel.us
www.zumtobel.ca
Australia and New Zealand
Zumtobel Lighting Pty Ltd
333 Pacific Highway
North Sydney, NSW 2060
T +61/(2)8913 5000
F +61/(2)8913 5001
M info@zumtobel.com.au
www.zumtobel.com.au
China
Zumtobel Lighting China
Beijing Office
T5-2-152 Tayuan Diplomatic Compound,
No. 1 Xin Dong Road, Chaoyang District
100600 Beijing
T +86/(10) 8532 3886
F +86/(10) 8532 3889
M admin@zumtobel.com.hk
Singapore
Zumtobel Lighting Singapore
No. 5 Kaki Bukit Crescent #04-03
416238 Singapore
T +65/(0)6848 2560
F +65/(0)6234 4972
M info@zumtobel.com.sg
Hong Kong
Zumtobel Lighting Hong Kong
Unit 319, Level 43,
Tower 1, Metroplaza,
223 Hing Fong Road,
Kwai Chung, N.T.
T +852/(0)2503 0466
F +852/(0)2503 0177
M admin@zumtobel.com.hk
United Arab Emirates
Zumtobel Lighting GmbH
Dubai Airport Free Zone,
3rd East Wing, 4th Floor, Office 413
PO Box 54620
Dubai
T +971/(4) 214 9845
F +971/(4) 214 9501
Norway
Zumtobel Belysning
Pilestredet 75 C
0354 Oslo
Postbox 5829 Majorstuen
0308 Oslo
T +47/22 46 85 00
F +47/22 46 85 02
M info.se@zumtobel.com
Sweden
Zumtobel Belysning
Birger Jarlsgatan 57
113 56 Stockholm
T +46/(0)8/26 26 50
F +46/(0)8/26 56 05
M info.se@zumtobel.com
www.zumtobel.se
Czech Republic and Slovak Republic
Zumtobel Lighting s.r.o.
Vlastislavova 11
Praha 4
140 00 Praha
T +420/(2) 41 740 301
F +420/(2) 41 740 308
M praha@zumtobel.com
www.zumtobel.cz
Poland
Zumtobel Lighting GmbH Sp.z.o.o.
Przedstawicielstwo w Polsce
ul. Narbutta 46/48
02-541 Warszawa
T +48/(22) 856 7431
F +48/(22) 856 7432
www.zumtobel.pl
Russia
Zumtobel Lighting GmbH
Official Representative Office
Skakovaya Str. 17
Bld. No 1, Office 1104
125040 Moscow
T +7/(495) 945 36 33
F +7/(495) 945 16 94
www.zumtobel.ru
Slovenia and Croatia
Zumtobel Licht d.o.o.
Dunajska cesta 159
1000 Ljubljana
T +386/(1) 56 09 820
F +386/(1) 56 09 866
M bzslowenien@zumtobel.si
www.zumtobel.si
Headquarters
Zumtobel Lighting GmbH
Schweizer Strasse 30
Postfach 72
6851 Dornbirn, AUSTRIA
T +43/(0)5572/390-0
F +43/(0)5572/22 826
Zumtobel Licht GmbH
Grevenmarschstrasse 74-78
32657 Lemgo, GERMANY
T +49/(0)5261/2 12-0
F +49/(0)5261/2 12-7777
www.zumtobel.de
www.zumtobel.com
Track and spots
Modular lighting systems
Down-/uplights
Recessed luminaires
Surface-mounted and pendant luminaires
LED, task, wall and uplights
Continuous row and batten luminaires
High-bay luminaires
Luminaires with extra protection
Lighting management
Emergency lighting
Medical supply systems
Art.-No. 04 900 033-UK 01/08
Zumtobel Lighting GmbH
Technical data was correct at time of going
to press. We reserve the right to make tech-
nical changes without notice. Please contact
your local sales office for further information.
Printed on environmentally-friendly chlorine-
free paper. Printed on Galaxy Bright.
www.zumtobel.com/onlite
Emergency lighting
systems with central
power supply.
ONLITE group and
central battery systems
excel by combining
maximum functionality
with seamless integra-
tion into the general
lighting system. They
are continuously moni-
tored high-performance
systems and guarantee
comprehensive safety.
ONLITE central

También podría gustarte