Está en la página 1de 258

User Manual

SRAL XD (single board IDU)


Low Capacity Digital Radio - 7...38 GHz
UMN

911-383/02C0000
Issue 3, March 2004

Copyright (C) Siemens Mobile Communications S.p.A. 2004


V.le Piero e Alberto Pirelli, 10
I-20126 Milano
Issued by Customer Documentation Department
S.S. 11 Padana Superiore, km 158
I-20060 Cassina de Pecchi MI
Technical modifications possible.
Technical specifications and features are binding only insofar as
they are specifically and expressly agreed upon in a written contract.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

STATUS OF MANUAL

STATUS OF MANUAL

Current:

Issue 3, March 2004

Previous:

Issue 2, December 2003


Issue 2, October 2003

In Issue 2, December 2003, chapter 2 has been modified.


In Issue 3, March 2004, the 7-8-13-28 GHz ND ODU, the 15 GHz HD/HP ODU and the
licence fees.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

R-1

LA

PA
G
E

STATUS OF MANUAL

R-2

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

INDEX

INDEX
STATUS OF MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R.1
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.1
LIST OF ILLUSTRATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.7
LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.11

PRELIMINARY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1


1.1
1.1.1
1.1.2

FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1
Object of the present manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1
Contents of the user manual (UMN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1

1.2
1.2.1
1.2.1.1
1.2.1.2
1.2.1.3
1.2.2

SAFETY RULES AND USE PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2


Safety rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2
Electrical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2
Dangerous materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2
External operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3
ESDS precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4

1.3

LIST OF ABBREVIATIONS AND ACRONYMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5

PLANNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1
2.1
2.1.1
2.1.2
2.1.3
2.1.4
2.1.4.1
2.1.4.2
2.1.5
2.1.5.1
2.1.5.2
2.1.5.3
2.1.5.4
2.1.5.5
2.1.6
2.1.7
2.1.7.1
2.1.8
2.1.8.1
2.1.8.2

SRAL XD FAMILY: THE EXTRA DENSITY SYSTEM FOR MULTIPLE HIGH-SPEED


NETWORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1
SRAL XD system described in this User Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8
System building . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.8
Network topologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.10
IDU-ODU Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.11
51.84 Mbit/s signal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.11
ODU Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.11
Physical interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12
Tributary signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12
User channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12
Alarm and remote control external lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.12
Monitoring of received RF power on the ODU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.13
Supervision interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.14
Loop-backs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.16
Tributary loop-backs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.16
Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.17
Licence fee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.19
Configuration summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.19

2.2
2.2.1
2.2.2
2.2.2.1
2.2.2.2
2.2.3

TECHNICAL CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.20


General characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.20
ODU ND characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.25
Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.25
Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.27
ODU HD/HP characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.28

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

I-1

INDEX

2.2.3.1
2.2.3.2
2.2.4
2.2.4.1
2.2.4.2
2.2.4.3
2.2.4.4
2.2.4.5
2.2.4.6
2.2.5
2.2.6
2.2.7
2.2.8
2.2.9

Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IDU characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hardware alarm detection time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operational switching time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Characteristics of 2 Mbit/s tributary interface (E1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Characteristics of channel auxiliary interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power supply characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guaranteed consumptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mechanical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Environmental conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EMC/EMI characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.28
2.32
2.34
2.34
2.34
2.34
2.34
2.35
2.36
2.37
2.37
2.37
2.38
2.40

2.3
EQUIPMENT COMPOSITION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.41
2.3.1
System configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.41
2.3.2
SRAL XD equipment composition (7 GHz P/N 832-042/07). . . . . . . . . . . . . . . . . . . . . . . . . . 2.42
2.3.3
SRAL XD equipment composition (8 GHz P/N 832-042/08). . . . . . . . . . . . . . . . . . . . . . . . . . 2.43
2.3.4
SRAL XD equipment composition (13 GHz P/N 832-042/13). . . . . . . . . . . . . . . . . . . . . . . . . 2.44
2.3.5
SRAL XD equipment composition (15 GHz P/N 832-042/15). . . . . . . . . . . . . . . . . . . . . . . . . 2.46
2.3.6
SRAL XD equipment composition (18 GHz P/N 832-042/18). . . . . . . . . . . . . . . . . . . . . . . . . 2.48
2.3.7
SRAL XD equipment composition (23 GHz P/N 832-042/23). . . . . . . . . . . . . . . . . . . . . . . . . 2.50
2.3.8
SRAL XD equipment composition (26 GHz P/N 832-042/23). . . . . . . . . . . . . . . . . . . . . . . . . 2.52
2.3.9
SRAL XD equipment composition (28 GHz P/N 832-042/28). . . . . . . . . . . . . . . . . . . . . . . . . 2.54
2.3.10 SRAL XD equipment composition (38 GHz P/N 832-042/38). . . . . . . . . . . . . . . . . . . . . . . . . 2.56
2.3.11 Antenna P/N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.58
2.3.12 Supporting frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.64
2.3.12.1 1+0 supporting frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.64
2.3.12.2 1+1 Supporting frame for Hot stand-by with integrated antenna . . . . . . . . . . . . . . . . . . . . . . 2.65
2.3.12.3 1+1 Supporting frame for Hot stand-by with independent antenna . . . . . . . . . . . . . . . . . . . . 2.66
2.3.13 IDU composition (Single Board) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.67
2.3.13.1 Licence fees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.68
2.3.13.2 Upgrading kits for on-field upgrading of the licence types . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.69
2.3.14 Connection accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.70
2.3.14.1 Standard installation materials with 75 ohm tributaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.70
2.3.14.2 Standard installation materials with 120 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.71
2.3.14.3 Optional installation materials. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.72
2.3.14.3.1Installation materials composition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.72
2.3.15 ODU identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.75
2.3.15.1 7 GHz ODU HD/HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.76
2.3.15.2 8 GHz ODU HD/HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.84
2.3.15.3 15 GHz ODU HD/HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.88
2.3.15.4 18 GHz ODU HD/HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.92
2.3.15.5 23 GHz ODU HD/HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.93
2.3.15.6 26 GHz ODU HD/HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.93
2.3.15.7 28 GHz ODU HD/HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.94
2.3.15.8 38 GHz ODU HD/HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.94
2.3.15.9 7 GHz ODU ND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.96
2.3.15.108 GHz ODU ND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.104
2.3.15.1113 GHz ODU ND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.108
2.3.15.1215 GHz ODU ND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.109
2.3.15.1318 GHz ODU ND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.112
2.3.15.1423 GHz ODU ND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.113
2.3.15.1526 GHz ODU ND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.115
2.3.15.1628 GHz ODU ND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.115

I-2

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

INDEX

2.3.15.1738 GHz ODU ND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.116

INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1
3.1

GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1

3.2
3.2.1
3.2.1.1
3.2.1.2
3.2.1.3
3.2.1.4
3.2.2
3.2.2.1
3.2.2.2
3.2.2.3
3.2.2.4
3.2.3
3.2.3.1
3.2.3.2
3.2.3.3
3.2.3.4
3.2.4
3.2.4.1
3.2.4.2

ODU FRAMES (7, 8 and 38 GHz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2


1+0 vertical frame dimensions with independent antenna (7, 8 and 38 GHz ODU) . . . . . . . . . 3.2
1+0 vertical frame - Flange types and part numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3
1+0 vertical frame - Pole mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4
1+0 vertical frame - Wall mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5
1+0 vertical frame - O-rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6
1+1 vertical frame dimensions with independent antenna (7/8 GHz ODU) . . . . . . . . . . . . . . . . 3.7
Attenuation values, flange types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.8
1+1 vertical frame - Pole mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.9
1+1 vertical frame - Wall mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.10
1+1 vertical frame - O-rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.11
1+1 vertical frame dimensions with independent antenna (ODU 15 GHz to 38 GHz). . . . . . . 3.12
Attenuation values, flange types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.13
1+1 vertical frame with independent antenna (15 GHz to 38 GHz ODU) - Pole mounting . . . 3.14
1+1 vertical frame with independent antenna (15 GHz to 38 GHz ODU) - Wall mounting . . . 3.15
1+1 vertical frame with independent antenna (15 GHz to 38 GHz ODU) - O-rings . . . . . . . . . 3.16
1+1 vertical frame dimensions with integrated antenna (15 GHz to 38 GHz ODU). . . . . . . . . 3.17
Attenuation values, flange types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.18
1+1 vertical frame with integrated antenna - O-rings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.20

3.3
3.3.1
3.3.2
3.3.3

NOT INTEGRATED SYSTEM (SOLUTION WITH FLEXIBLE WAVEGUIDE) . . . . . . . . . . . . 3.21


Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.21
Attenuation and P/N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.22
Pole overall size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.23

3.4
3.4.1
3.4.2
3.4.3

NOT INTEGRATED SYSTEM (SOLUTION WITH ELLIPTICAL WAVEGUIDE) . . . . . . . . . . . 3.24


Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.24
Pressurization with external dehydrator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.25
Elliptical flexible waveguide, connector and accessory versions. . . . . . . . . . . . . . . . . . . . . . . 3.26

3.5
3.5.1
3.5.2
3.5.2.1
3.5.2.2
3.5.3
3.5.4
3.5.5
3.5.6

ODU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.33
Assembly on support frame. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.33
ODU dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.34
ODU Normal Density (ND) dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.34
ODU High Density (HD) dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.35
ODU versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.36
Vertical polarization application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.37
Horizontal polarization application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.38
Rx field measure connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.39

3.6
3.6.1
3.6.2
3.6.3
3.6.4
3.6.5
3.6.5.1
3.6.6
3.6.7

IDU/ODU CONNECTION WITH BRAIDED COAXIAL CABLE . . . . . . . . . . . . . . . . . . . . . . . . 3.40


IDU/ODU typical connection with Braided coaxial cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.40
Grounding connections, integrated solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.41
Grounding connections, not integrated solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.42
Pole fixing of the grounding plate kit (P/N 332-309/91) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.43
Braided coaxial cable - Typical fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.44
Recommended clamp spacing for Braided coaxial cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.45
Andrew and Intercond sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.46
Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.47

3.7

IDU/ODU CONNECTION WITH 1/4 COAXIAL CABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.49

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

I-3

INDEX

3.7.1
3.7.2
3.7.3
3.7.4
3.7.5
3.7.6
3.7.6.1
3.7.7
3.7.8
3.7.9

IDU/ODU typical connection with 1/4 coaxial cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


ODU side connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Grounding connections, integrated solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Grounding connections, not integrated solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pole fixing of the grounding plate kit (P/N 332-309/91) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1/4 coaxial cable - Typical fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recommended clamp spacing for 1/4 coaxial cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1/4 coaxial cable - Connection on IDU side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Andrew and RFS-Kabelmetal sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.49
3.50
3.51
3.52
3.53
3.54
3.55
3.56
3.57
3.58

3.8
3.8.1
3.8.2
3.8.3
3.8.4
3.8.4.1

IDU INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Board IDU sub-rack arrangement for ETSI rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Board IDU sub-rack arrangement for 19 rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Board IDU sub-rack installation in the rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Board IDU grounding connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.62
3.62
3.63
3.64
3.65
3.66

3.9
3.9.1
3.9.2

EXTERNAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.67


Primary supply voltage connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.67
Connector functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.69

ACTIVATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1
4.1
4.1.1
4.1.2

PRESETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1
Hardware settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1
System E2PROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1

4.2
4.2.1
4.2.2
4.2.3
4.2.4
4.2.4.1
4.2.4.2
4.2.5
4.2.5.1
4.2.5.2
4.2.5.3

ACTIVATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Local checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IDU first installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Local checks on the equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control of the system configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration of IP address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Link checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Final checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switching test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Restore of the operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.3
4.3.1
4.3.2

NORMAL OPERATING CONDITIONS AND ALARMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.6


Normal operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.6
Alarm conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.6

MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1
5.1
5.1.1
5.1.2
5.1.2.1
5.1.2.2
5.1.2.3
5.1.3
5.1.3.1
5.1.3.2

I-4

4.2
4.2
4.2
4.4
4.5
4.5
4.5
4.5
4.5
4.5
4.5

TROUBLESHOOTING AND RESTORING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacement procedures in 1+0 systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ODU replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IDU-ODU cable replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IDU (Single Board) replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit replacement procedures in 1+1 systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ODU replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IDU-ODU cable replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.1
5.1
5.2
5.2
5.2
5.2
5.3
5.3
5.3

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

INDEX

5.1.3.3
5.1.4

IDU (Single Board) replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3


Configuration change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4

5.2
5.2.1
5.2.2

LIST OF SPARE PARTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6


Single Board IDU spare parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6
ODU spare parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6

5.3
5.3.1
5.3.2

PROCEDURE FOR SPARE PARTS USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.9


Procedure for the IDU replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.9
Procedure for the ODU replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.9

FUNCTIONAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1


6.1
6.1.1
6.1.2
6.1.3

IDU ARCHITECTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1


2 Mbit/s (8xE1 or 16xE1) Tributary section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1
BB, Adapter, LIU and Cable Interface section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2
Controller section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2

6.2
6.2.1
6.2.2
6.2.3
6.2.4
6.2.5
6.2.6

ODU ARCHITECTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5


BB-I ( Base-Band and Cable Interface ) Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5
Power Supply Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.6
Modem Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.6
Controller Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.6
IF section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.6
RF Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.6

6.3
6.3.1

PROTECTION SYSTEM ARCHITECTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.7


Radio Hardware protection logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.7

6.4
6.4.1
6.4.2
6.4.3

SERVICE CHANNELS MANAGEMENT AND PROTECTION . . . . . . . . . . . . . . . . . . . . . . . . . 6.9


User channel (USR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9
Radio Embedded Communication Channel (R) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.10
Tributary Embedded Communication Channel (D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.11

6.5

LED, MONITORING POINTS, CONNECTORS AND SWITCHES . . . . . . . . . . . . . . . . . . . . . 6.12

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

I-5

LA

PA
G
E

INDEX

I-6

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

LIST OF ILLUSTRATIONS

LIST OF ILLUSTRATIONS
Fig. 2.1
Fig. 2.2
Fig. 2.3
Fig. 2.4
Fig. 2.5
Fig. 2.6
Fig. 2.7
Fig. 2.8
Fig. 2.9
Fig. 2.10
Fig. 2.11
Fig. 2.12
Fig. 2.13
Fig. 2.14
Fig. 2.15
Fig. 2.16
Fig. 2.17
Fig. 2.18
Fig. 2.19
Fig. 2.20
Fig. 2.21
Fig. 2.22
Fig. 2.23
Fig. 2.24
Fig. 2.25
Fig. 2.26
Fig. 2.27
Fig. 2.28
Fig. 2.29
Fig. 2.30
Fig. 2.31
Fig. 2.32
Fig. 2.33
Fig. 2.34
Fig. 2.35
Fig. 2.36
Fig. 2.37
Fig. 2.38
Fig. 2.39
Fig. 2.40
Fig. 2.41
Fig. 2.42
Fig. 2.43
Fig. 2.44
Fig. 3.1
Fig. 3.2
Fig. 3.3

System architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3


Plug-in IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4
Single Board IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4
MinIDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5
Normal Density ODU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6
High Density/High Performance ODU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6
SRAL XD Suit Cross Compatibilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7
SRAL XD equipment block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.9
STAR topology (protected or unprotected links). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.10
MULTIDROP topology (add/drop or back-to-back links) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.10
LOOP topology (add/drop or back-to-back links) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.10
IDU physical interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.13
Network supervision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15
Tributary loop-back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.16
SRAL XD equipment: 1+0 configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.17
SRAL XD equipment: 16E1 (1+0) configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.18
SRAL XD equipment: 8xE1 (1+1) H/S configuration with one antenna . . . . . . . . . . . . . . . . . . . . . 2.18
SRAL XD equipment: 16xE1 (1+1) H/S with one antenna configuration . . . . . . . . . . . . . . . . . . . . 2.19
ETSI Block diagram of Tx RF side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.25
Mask of the RF signal for 7 GHz to 38 GHz ODU ND according to the traffic capacity . . . . . . . . . 2.26
ETSI Block diagram of Rx RF side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.27
ETSI Block diagram of Tx RF side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.28
Mask of the RF signal for 7 GHz to 38 GHz ODU (HP mode) according to the traffic capacity . . . 2.29
Mask of the RF signal for 23, 26, 28 and 38 GHz ODU (HD mode) according to the traffic
capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.30
Mask of the RF signal for 7, 8, 15 and 18 GHz ODU (HD mode) according to the traffic capacity 2.31
ETSI Block diagram of Rx RF side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.32
Shape of 2 Mbit/s tributary interface output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.35
Temperature/humidity climatic diagram for IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.38
Temperature/humidity climatic diagram for ODU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.39
Temperature/humidity climatic diagram for IDU-ODU storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.39
1+0 system with 1 integrated antenna (Terminal) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.59
1+0 system with 1 independent antenna (Terminal). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.60
SRAL XD - 7/8 GHz: 1+1 H/S system with 1 independent antenna (Terminal) . . . . . . . . . . . . . . . 2.61
SRAL XD - 15 to 38 GHz: 1+1 H/S system with 1 integrated antenna (Terminal) . . . . . . . . . . . . . 2.62
SRAL XD - 15 to 38 GHz: 1+1 H/S system with 1 independent antenna (Terminal) . . . . . . . . . . . 2.63
1+0 supporting frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.64
1+1 Supporting frame for Hot stand-by . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.65
1+1 Supporting frame for Hot stand-by . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.66
1+0/8xE1 Single Board IDU front view - P/N 732-101/71A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.67
1+0/16xE1 Single Board IDU front view - P/N 732-101/71C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.67
1+1/8xE1 Single Board IDU front view - P/N 732-101/71G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.67
1+1/16xE1 Single Board IDU front view - P/N 732-101/71E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.67
7, 8, 15, 18, 23, 26, 28 and 38 GHz ODU HD/HP: Diplexer position according to the
mounting type (A or B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.95
7, 8, 13, 15, 18, 23, 26, 28 and 38 GHz ODU ND: Diplexer position according to the
mounting type (A or B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.117
1+0 vertical frame dimensions with independent antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2
1+0 vertical frame - Pole mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4
1+0 vertical frame - Wall mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

I-7

LIST OF ILLUSTRATIONS

Fig. 3.4
Fig. 3.5
Fig. 3.6
Fig. 3.7
Fig. 3.8
Fig. 3.9
Fig. 3.10
Fig. 3.11
Fig. 3.12
Fig. 3.13
Fig. 3.14
Fig. 3.15
Fig. 3.16
Fig. 3.17
Fig. 3.18
Fig. 3.19
Fig. 3.20
Fig. 3.21
Fig. 3.22
Fig. 3.23
Fig. 3.24
Fig. 3.25
Fig. 3.26
Fig. 3.27
Fig. 3.28
Fig. 3.29
Fig. 3.30
Fig. 3.31
Fig. 3.32
Fig. 3.33
Fig. 3.34
Fig. 3.35
Fig. 3.36
Fig. 3.37
Fig. 3.38
Fig. 3.39
Fig. 3.40
Fig. 3.41
Fig. 3.42
Fig. 3.43
Fig. 3.44
Fig. 3.45
Fig. 3.46
Fig. 3.47
Fig. 3.48
Fig. 3.49
Fig. 3.50
Fig. 3.51
Fig. 3.52
Fig. 3.53
Fig. 3.54
Fig. 3.55
Fig. 3.56
Fig. 4.1
Fig. 4.2

I-8

1+0 vertical frame - O-rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6


1+1 vertical frame dimensions with independent antenna. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.7
1+1 vertical frame - Pole mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.9
1+1 vertical frame - Wall mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.10
1+1 vertical frame - O-rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.11
1+1 vertical frame dimensions with independent antenna. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.12
1+1 vertical frame with independent antenna (15 GHz to 38 GHz ODU) - Pole mounting . . . . . . 3.14
1+1 vertical frame with independent antenna (15 GHz to 38 GHz ODU) - Wall mounting . . . . . . 3.15
1+1 vertical frame with independent antenna (15 GHz to 38 GHz ODU) - O-rings . . . . . . . . . . . . 3.16
1+1 vertical frame dimensions with integrated antenna. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.17
1+1 vertical frame with integrated antenna - Polarization change . . . . . . . . . . . . . . . . . . . . . . . . . 3.19
1+1 vertical frame with integrated antenna - O-rings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.20
Connections (solution with flexible waveguide) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.21
Pole overall size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.23
Connections (solution with elliptical waveguide) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.24
Pressurization with external dehydrator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.25
ODU assembly on support frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.33
ODU Normal Density (ND) dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.34
ODU High Density (HD) dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.35
Vertical polarization application (ODU Normal Density - ND) . . . . . . . . . . . . . . . . . . . . . . . . . . 3.37
Vertical polarization application (ODU High Density - HD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.37
Horizontal polarization application (ODU Normal Density - ND) . . . . . . . . . . . . . . . . . . . . . . . . 3.38
Horizontal polarization application (ODU High Density - HD) . . . . . . . . . . . . . . . . . . . . . . . . . . 3.38
Rx field measure connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.39
Braided coaxial cable - IDU/ODU tipical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.40
Grounding connections, integrated solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.41
Grounding connections, not integrated solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.42
Pole fixing of the grounding plate kit (P/N 332-309/91) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.43
Braided coaxial cable - Typical fixing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.44
1/4 coaxial cable - IDU/ODU tipical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.49
1/4 coaxial cable - ODU side connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.50
Grounding connections, integrated solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.51
Grounding connections, not integrated solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.52
Pole fixing of the grounding plate kit (P/N 332-309/91) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.53
1/4 coaxial cable - Typical fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.54
1/4 coaxial cable - Connection on IDU side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.56
Single Board IDU sub-rack arrangement for ETSI rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.63
Single Board IDU sub-rack arrangement for 19 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.64
Single Board IDU sub-rack installation in the rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.65
Single Board IDU grounding connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.66
Primary Power Supply Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.68
ODU connections (SMA coax. connector) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.69
2 Mbit/s 120 ohm (SUB-D) from 1 to 8 Tributary Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.70
2 Mbit/s 120 ohm (SUB-D) from 9 to 16 Tributary Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 3.71
2 Mbit/s 75 ohm (SUB-D) from 1 to 8 Tributary Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.72
2 Mbit/s 75 ohm (SUB-D) from 9 to 16 Tributary Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.73
Alarm connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.74
64 kbit/s (V.11) service channel connnection: USER/Dext (USER 1) . . . . . . . . . . . . . . . . . . . . . . 3.76
64 kbit/s (V11) service channel connnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.77
Supervision connections (Q LAN - V LAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.78
Connection example (Q LAN - V LAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.78
LCT connection (RS 232) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.79
Example of the F interface used to extend a SRAL network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.80
IDU Key position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3
ODU connection for the measurement of the received field (Rx field). . . . . . . . . . . . . . . . . . . . . . . 4.4

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

LIST OF ILLUSTRATIONS

Fig. 4.3
Fig. 5.1
Fig. 5.2
Fig. 6.1
Fig. 6.2
Fig. 6.3
Fig. 6.4
Fig. 6.5
Fig. 6.6
Fig. 6.7
Fig. 6.8
Fig. 6.9
Fig. 6.10
Fig. 6.11
Fig. 6.12

LEDs status in the normal operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.6


LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1
Flow chart No. 1 - Intervention procedure because of failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5
SRAL XD: 8xE1 (1+0) configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3
SRAL XD: 16xE1 (1+0) configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3
SRAL XD: 8xE1 (1+1) H/S with one antenna configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.4
SRAL XD: 16xE1 (1+1) H/S with one antenna configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.4
ODUs functional block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5
Alarms of Radio Hardware protection logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.7
Configuration of User channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.10
Configuration of R channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.10
Configuration of D channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.11
IDU front panel in 1+1 configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.12
LED position on the front panel of the Single Board IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.13
LED 1 and LED 2 position on the front panel of the Single Board IDU. . . . . . . . . . . . . . . . . . . . . . 6.13

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

I-9

LA

PA
G
E

LIST OF ILLUSTRATIONS

I-10

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

LIST OF TABLES

LIST OF TABLES
Tab. 2.1
Tab. 2.2
Tab. 2.3
Tab. 2.4
Tab. 2.5
Tab. 2.6
Tab. 2.7
Tab. 2.8
Tab. 2.9
Tab. 2.10
Tab. 2.11
Tab. 2.12
Tab. 2.13
Tab. 2.14
Tab. 2.15
Tab. 2.16
Tab. 2.17
Tab. 2.18
Tab. 2.19
Tab. 2.20
Tab. 2.21
Tab. 2.22
Tab. 2.23
Tab. 2.24
Tab. 2.25
Tab. 2.26
Tab. 2.27
Tab. 2.28
Tab. 2.29
Tab. 2.30
Tab. 2.31
Tab. 2.32
Tab. 2.33
Tab. 2.34
Tab. 2.35
Tab. 2.36
Tab. 2.37
Tab. 2.38
Tab. 2.39
Tab. 2.40
Tab. 2.41
Tab. 2.42
Tab. 2.43
Tab. 2.44
Tab. 2.45
Tab. 2.46
Tab. 2.47
Tab. 2.48
Tab. 2.49
Tab. 2.50

Configuration summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.19


RF signal attenuation limit values (7 GHz to 38 GHz - ND) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.26
RF signal attenuation limit values (7 GHz to 38 GHz - HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.29
RF signal attenuation limit values (23, 26, 28 and 38 GHz - HD) . . . . . . . . . . . . . . . . . . . . . . . . . . 2.30
RF signal attenuation limit values (7, 8, 15 and 18 GHz - HD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.31
System configurations for SRAL XD equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.41
SRAL XD equipment composition [7 GHz in 1+0 configuration]. . . . . . . . . . . . . . . . . . . . . . . . . . . 2.42
SRAL XD equipment composition [7 GHz in 1+1 H/S configuration with 1 antenna] . . . . . . . . . . . 2.42
SRAL XD equipment composition [8 GHz in 1+0 configuration]. . . . . . . . . . . . . . . . . . . . . . . . . . . 2.43
SRAL XD equipment composition [8 GHz in 1+1 H/S configuration with 1 antenna] . . . . . . . . . . . 2.43
SRAL XD equipment composition [13 GHz in 1+0 configuration]. . . . . . . . . . . . . . . . . . . . . . . . . . 2.44
SRAL XD equipment composition [13 GHz in 1+1 H/S configuration] with 1 antenna . . . . . . . . . . 2.45
SRAL XD equipment composition [15 GHz in 1+0 configuration]. . . . . . . . . . . . . . . . . . . . . . . . . . 2.46
SRAL XD equipment composition [15 GHz in 1+1 H/S configuration] with 1 antenna . . . . . . . . . . 2.47
SRAL XD equipment composition [18 GHz in 1+0 configuration]. . . . . . . . . . . . . . . . . . . . . . . . . . 2.48
SRAL XD equipment composition [18 GHz in 1+1 H/S configuration] with 1 antenna . . . . . . . . . . 2.49
SRAL XD equipment composition [23 GHz in 1+0 configuration]. . . . . . . . . . . . . . . . . . . . . . . . . . 2.50
SRAL XD equipment composition [23 GHz in 1+1 H/S configuration] with 1 antenna . . . . . . . . . . 2.51
SRAL XD equipment composition [26 GHz in 1+0 configuration]. . . . . . . . . . . . . . . . . . . . . . . . . . 2.52
SRAL XD equipment composition [26 GHz in 1+1 H/S configuration] with 1 antenna . . . . . . . . . . 2.53
SRAL XD equipment composition [28 GHz in 1+0 configuration]. . . . . . . . . . . . . . . . . . . . . . . . . . 2.54
SRAL XD equipment composition [28 GHz in 1+1 H/S configuration] with 1 antenna . . . . . . . . . . 2.55
SRAL XD equipment composition [38 GHz in 1+0 configuration]. . . . . . . . . . . . . . . . . . . . . . . . . . 2.56
SRAL XD equipment composition [38 GHz in 1+1 H/S configuration] with 1 antenna . . . . . . . . . . 2.57
Antenna P/N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.58
1+0 supporting frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.64
1+1 Supporting frame for Hot stand-by with integrated antenna . . . . . . . . . . . . . . . . . . . . . . . . . . 2.65
1+1 Supporting frame for Hot stand-by with independent antenna . . . . . . . . . . . . . . . . . . . . . . . . 2.66
Licence key P/Ns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.68
Upgrading kit P/Ns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.69
Standard installation materials with 75 ohm tributaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.70
Standard installation materials with 120 ohm tributaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.71
Alarm connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.72
Data channel connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.72
LAN connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.72
IDU connection kit - P/N 597-525/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.72
Tributary connection kit - P/N 332-055/57 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.73
Alarm connector composition: P/N 332-055/49A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.73
User/Dext connector composition: P/N 332-055/29A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.73
(IN/OUT) 50 ohm Braided coaxial cable and ANDREW accessories set . . . . . . . . . . . . . . . . . . . . 2.73
(IN/OUT) 50 ohm Braided coaxial cable and INTERCOND accessories set . . . . . . . . . . . . . . . . . 2.74
ODU (7.4 - 7.7 GHz) composition; Fs=154 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.76
ODU (7.1 - 7.4 GHz) composition; Fs=161 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.77
ODU (7.4 - 7.7 GHz) composition; Fs=161 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.78
ODU (7.4 - 7.9 GHz) composition; Fs=245 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.79
ODU (7.75 - 7.975 GHz) composition; Fs=148.5 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.81
ODU (7.1 - 7.4 GHz) composition; Fs=196 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.82
ODU (7.4 - 7.7 GHz) composition; Fs=168 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.83
ODU (7.7 - 8.2 GHz) composition; Fs=311.25 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.84
ODU (7.7 - 8.2 GHz) composition; Fs=311.25 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.85

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

I-11

LIST OF TABLES

Tab. 2.51
Tab. 2.52
Tab. 2.53
Tab. 2.54
Tab. 2.55
Tab. 2.56
Tab. 2.57
Tab. 2.58
Tab. 2.59
Tab. 2.60
Tab. 2.61
Tab. 2.62
Tab. 2.63
Tab. 2.64
Tab. 2.65
Tab. 2.66
Tab. 2.67
Tab. 2.68
Tab. 2.69
Tab. 2.70
Tab. 2.71
Tab. 2.72
Tab. 2.73
Tab. 2.74
Tab. 2.75
Tab. 2.76
Tab. 2.77
Tab. 2.78
Tab. 2.79
Tab. 2.80
Tab. 2.81
Tab. 2.82
Tab. 2.83
Tab. 2.84
Tab. 2.85
Tab. 2.86
Tab. 2.87
Tab. 2.88
Tab. 2.89
Tab. 2.90
Tab. 2.91
Tab. 3.1
Tab. 3.2
Tab. 3.3
Tab. 3.4
Tab. 3.5
Tab. 3.6
Tab. 3.7
Tab. 3.8
Tab. 3.9
Tab. 3.10
Tab. 3.11
Tab. 3.12
Tab. 3.13
Tab. 3.14

I-12

ODU (8.275-8.5 GHz) composition; Fs=126 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.86


ODU (8.275-8.5 GHz) composition; Fs=119 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.87
ODU (14.40 - 15.35 GHz) composition; Fs=336 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.88
ODU (14.40 - 15.35 GHz) composition; Fs=420 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.89
ODU (14.40 - 15.35 GHz) composition; Fs=728 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.89
ODU (14.40 - 15.35 GHz) composition; Fs=490 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.90
ODU (14.40 - 15.35 GHz) composition; Fs=315 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.90
ODU (14.40 - 15.35 GHz) composition; Fs=322 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.91
ODU (17.7 - 19.7 GHz) composition; Fs=340 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.92
ODU (17.7 - 19.7 GHz) composition; Fs=1010 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.92
ODU (21.2 - 23.6 GHz) composition; Fs=1008 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.93
ODU (24.5 - 26.5 GHz) composition; Fs=1008 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.93
ODU (28.5 - 29.5 GHz) composition; Fs=1008 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.94
ODU (37 - 39.5 GHz) composition; Fs=1260 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.94
ODU (7.4 - 7.7 GHz) composition; Fs=154 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.96
ODU (7.1 - 7.4 GHz) composition; Fs=161 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.97
ODU (7.4 - 7.7 GHz) composition; Fs=161 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.98
ODU (7.4 - 7.9 GHz) composition; Fs=245 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.99
ODU (7.75 - 7.975 GHz) composition; Fs=148.5 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.101
ODU (7.1 - 7.4 GHz) composition; Fs=196 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.102
ODU (7.4 - 7.7 GHz) composition; Fs=168 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.103
ODU (7.7 - 8.2 GHz) composition; Fs=311.25 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.104
ODU (7.7 - 8.2 GHz) composition; Fs=311.25 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.105
ODU (8.275-8.5 GHz) composition; Fs=126 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.106
ODU (8.275-8.5 GHz) composition; Fs=119 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.107
ODU (12.75 - 13.25 GHz) composition; Fs=266 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.108
ODU (14.5 - 15.4 GHz) composition; Fs=336 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.109
ODU (14.5 - 15.4 GHz) composition; Fs=420 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.109
ODU (14.5 - 15.4 GHz) composition; Fs=728 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.110
ODU (14.5 - 15.4 GHz) composition; Fs=490 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.110
ODU (14.5 - 15.4 GHz) composition; Fs=315 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.111
ODU (14.5 - 15.4 GHz) composition; Fs=322 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.111
ODU (17.7 - 19.7 GHz) composition; Fs=340 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.112
ODU (17.7 - 19.7 GHz) composition; Fs=1010 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.112
ODU (17.7 - 19.7 GHz) composition; Fs=1560 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.113
ODU (21.2 - 23.6 GHz) composition; Fs=1008 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.113
ODU (21.2 - 23.6 GHz) composition; Fs=1232 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.114
ODU (21.2 - 23.6 GHz) composition; Fs=1200 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.114
ODU (24.5 - 26.5 GHz) composition; Fs=1008 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.115
ODU (27.5 - 29.5 GHz) composition; Fs=1008 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.115
ODU (37 - 39.5 GHz) composition; Fs=1260 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.116
1+0 vertical frame - Flange types and part numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3
1+1 vertical frame - Attenuation values, flange types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.8
1+1 support frame with independent antenna - Attenuation values, flange types . . . . . . . . . . . . . 3.13
1+1 support frame with integrated antenna - Attenuation values, flange types . . . . . . . . . . . . . . . 3.18
Attenuation and P/N. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.22
Elliptical wave guide (31263-750) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.26
Connectors and accessories (31263-778SR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.26
Elliptical wave guide (31263-758) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.27
Connectors and accessories (31263-779SR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.27
Elliptical wave guide (31263-766) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.28
Connectors and accessories (31263-781SR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.28
Elliptical wave guide (31263-767) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.29
Connectors and accessories (31263-782SR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.29
Elliptical wave guide (31263-768) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.30

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

LIST OF TABLES

Tab. 3.15
Tab. 3.16
Tab. 3.17
Tab. 3.18
Tab. 3.19
Tab. 3.20
Tab. 3.21
Tab. 3.22
Tab. 3.23
Tab. 3.24
Tab. 3.25
Tab. 3.26
Tab. 3.27
Tab. 3.28
Tab. 3.29
Tab. 3.30
Tab. 3.31
Tab. 3.32
Tab. 3.33
Tab. 3.34
Tab. 3.35
Tab. 3.36
Tab. 3.37
Tab. 3.38
Tab. 3.39
Tab. 4.1
Tab. 5.1
Tab. 5.2
Tab. 5.3
Tab. 5.4
Tab. 5.5
Tab. 5.6
Tab. 5.7
Tab. 5.8
Tab. 5.9
Tab. 5.10
Tab. 5.11
Tab. 5.12
Tab. 5.13
Tab. 5.14
Tab. 5.15
Tab. 5.16
Tab. 5.17
Tab. 5.18
Tab. 6.1
Tab. 6.2

Connectors and accessories (31263-783SR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.30


Elliptical wave guide (31263-769). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.31
Connectors and accessories (31263-784SR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.31
Elliptical wave guide (31263-771). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.32
Connectors and accessories (31263-785R) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.32
ODU versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.36
ANDREW set (a). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.46
INTERCOND set (a) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.46
Construction characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.47
Mechanical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.47
Range of temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.47
Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.47
Attenuation, (dB/100) Standard conditions: VSWR 1.0; ambient temperature 24C . . . . . . . . . . . 3.48
Average Power Rating, kW Standard conditions : VSWR 1.0 ; ambient temperature 40C ;
inner conductor temperature 100C ; . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.48
Andrew set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.57
RFS-Kabelmetal set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.57
Construction characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.58
Mechanical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.58
Range of temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.58
Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.59
Attenuation, (dB/100m) Standard conditions: VSWR 1.0 ; ambient temperature 24C . . . . . . . . . 3.60
Average Power Rating, kW Standard conditions : VSWR 1.0 ; ambient temperature 40C ;
inner conductor temperature 100C ; . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.61
Fixing kit (P/N 332-309/83) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.62
Alarm meaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.75
LCT connector (RS 232). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.79
KEY alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3
List of spare parts - Single Board IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6
ODU HD/HP 7 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6
ODU HD/HP 8 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6
ODU HD/HP 15 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6
ODU HD/HP 18 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6
ODU HD/HP 23 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7
ODU HD/HP 26 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7
ODU HD/HP 28 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7
ODU HD/HP 38 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7
ODU ND 7 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7
ODU ND 8 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7
ODU ND 13 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7
ODU ND 15 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7
ODU ND 18 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8
ODU ND 23 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8
ODU ND 26 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8
ODU ND 28 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8
ODU ND 38 GHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8
User channel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.9
Summary of the front panel LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.14

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

I-13

LA

PA
G
E

LIST OF TABLES

I-14

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

1 - PRELIMINARY INFORMATION

1 PRELIMINARY INFORMATION
1.1 FOREWORD
1.1.1

Object of the present manual


This User Manual (UMN) gives the information necessary for the installation, the
commissioning and the ordinary maintenance of the SRAL XD in the RF band 7 GHz,
8 GHz, 13 GHz, 15 GHz, 18 GHz, 23 GHz, 26 GHz, 28 GHz and 38 GHz.

1.1.2

Contents of the user manual (UMN)


The manual has been drawn up according to "Code of Practice" recommendations for
the writing out of instruction technical manuals, published under the support of U.E.R
(European Broadcast Union).
The manual consists of the following sections:

Section 1: PRELIMINARY INFORMATION


It contains the rules and precautionary measures to be adopted by the users of
electronic equipment as well as general nature information relevant to the
synchronous hierarchy.

Section 2: PLANNING MANUAL


It contains general information about the equipment, its electrical characteristics
and its use with a telecommunication network.

Section 3: INSTALLATION MANUAL


All the instructions are set down for the equipment mechanical installation,
complete of the constituting parts, and of the electrical connections to the outside.

Section 4: ACTIVATION MANUAL


The presetting to be performed on the equipment, if required, are described, its
activation and the check and recommended setting up measurements to ensure
the correct operation.

Section 5: MAINTENANCE MANUAL


It includes troubleshooting action, if required, useful to locate the faulty part using
the signalings and alarms available on the equipment front panel. It also includes
the list of the spare parts which can be delivered with the equipment and the
instructions for the faulty part replacement.

Section 6: FUNCTIONAL DESCRIPTIONS


It includes the description of the equipment part operation referred to the relevant
block diagrams.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

1-1

1 - PRELIMINARY INFORMATION

In addition to the present User Manual (UMN) the OPERATOR MANUAL (OMN) is
available, that contains the operational guide for use of the control software developped
for the management, by local terminal, of the alarms and the presetting relevant to the
equipment, in addition to the restitution of the analogue measurements, of the
indications and configuration displayings of the radio system.

1.2 SAFETY RULES AND USE PRECAUTIONS


This paragraph contents all the safety rules and the use precautions to be followed
during operations on the equipment to avoid injuries to personnel and/or damages to the
equipment components.

1.2.1

Safety rules
The equipment complies with the 89/336/EEC European specification.
The equipment is prearranged for supplying from station batteries (-48 VDC 20%);
then follow the on force specifications for low voltage supplied equipment's.

1.2.1.1

Electrical safety
The equipment complies with the Safety Norms CEI EN 60950-1.
The equipment must be installed, started up, managed and repaired only by properly
trained personnel.

1.2.1.2

Before supplying the equipment, it is necessary to complete the wiring of the


connections to the protection ground, the insertion of all the units and/or modules
provided for the requested configuration and also the connection of all the
necessary connectors.

The connection to the protection ground must not be removed or damaged.

Dangerous materials
The radio equipment at the end of its life can be classified as 16 02 14 equipment out
of use different from the equipment listed in 16 02 09 to 16 02 13 according to the
dangerous waste list determined in article 1 para. 4 of Government Recc. 91/689/EEC
on the dangerous waste updated in Recc. 2001/118/EC.
The equipment does not include:

Cadmium

Mercury

Asbestos

Radioactive materials

PCB

Berillium

1-2

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

1 - PRELIMINARY INFORMATION

1.2.1.3

External operations
Some other operations involving danger conditions are the ones executed outside
during the equipment installation and starting up phase.
During the execution of such operations, it is necessary to follow strictly the safety rules
listed here below:

During installation, while the antenna and/or the external supporting-frame for rod
are lifted, it is strictly forbidden to stay or to pass in the underlying area. Such an
area must be properly restricted or signalled according to the on force rules.

For the external operations to be executed on the antenna, on the frame and on
the ODU, all the necessary safety rules against accidental fallings of the operators
must be respected, according to the on force rules. For example, it is necessary to
use protection fences and belts.

During the equipment starting up phase, the operators must not be in front of the
antenna.

If one of the above mentioned safety rules is not respected, some injuries to the
personnel can be caused.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

1-3

1 - PRELIMINARY INFORMATION

1.2.2

ESDS precautions
The ESDS (Electro Static Discharge Sensitive) electronic devices can be partially or
permanently damaged by the static electricity that is commonly present in the operating
environment.
The main ESDS devices are:

CMOS components

Large Scale Integration components in MOS technology

SAW (Surface Acoustic Wave) components

Operational amplifiers with MOS/FET inputs

MOS/FET components and arrays

Microwave semiconductors and microcircuits at frequencies > 1 GHz

Modules containing ESDS devices are identified by following adhesive labels:

In order avoid any damage while handling the modules, the user should wear an
antistatic elastic bracelet, grounded by means a spiral cord.
Those modules that are mounted on the equipment (faulty or spare parts) shall be stores
in their original antistatic package marked by the labels above shown.

1-4

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

1 - PRELIMINARY INFORMATION

1.3 LIST OF ABBREVIATIONS AND ACRONYMS


A/D-RPT

Add/Drop Repeater

AC

Alternating Current

ACI

Adjacent Channel Interference

AGC

Automatic Gain Control

ALM

Alarm

ATPC

Automatic Transmit Power Control

AUX

Auxiliary

BB

Base Band

BER

Bit Error Rate

BOL

Beginning Of Life

BSC

Basic Station Center

BTS

Basic Terminal Station

CCI

Co-Channel Interference

CH

Channel

CMD

Command

CPM

Continuous Phase Modulation

CW

Continuos Wave

D/A

Digital/Analog

DC

Direct Current

DCE

Data Communication Equipment

DEM

Demodulator

DTE

Data Terminal Equipment

DTMF

Dual Tone Multi Frequency

EM

ElectroMagnetic

EN

Enable

EOL

End Of Life

ESDS

Electro Static Discharge Sensitive

EXT

External

FD

Frequency Diversity

FEC

Forward Error Corrector

GA

Gate Array

GND

Ground

High

H/S

Hot-Standby

HD

High Density

HDB3

High Density Bipolar 3

HDLC

High Data Link Control

HL

Hitless

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

1-5

1 - PRELIMINARY INFORMATION

1-6

HP

High Performance

HW

Hardware

I/O

Input/Output

IC

Integrated Circuit

ID

Identifier

IDU

Indoor Unit

IF

Intermediate Frequency

IN

Input

IND

Indicative

INT

Internal

ITMN

Installation Test Manual

Low

LCT

Local Craft Terminal

LIU

Line Interface Unit

LSI

Large Scale Integration

MEM

Memorization

MOD

Modulator

MSC

Mobile Service switching Center

MTTR

Mean Time To Repair

ND

Normal Density

NE

Network Element

NRZ

Not Return-to-Zero

NURG

Not Urgent

ODU

Outdoor Unit

OMC

Operation & Maintenance Center

OSI

Open System Interconnection

OUT

Output

OW

Overflow

PC

Personal Computer

PD

Polarization Diversity

PDH

Plesiochronous Digital Hierarchy

PLL

Phase Lock Loop

QAM

Quadrature Amplitude Modulation

RF

Radio Frequency

RIEP

Recapitulary

RPT

Repeater

RS

Reed Solomon

Rx

Reception

S/I

Sensitivity/Interference

SRAL

Siemens Radio Access a bassa capacit

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

1 - PRELIMINARY INFORMATION

SW

Software

TCM

Trellis Code Modulation

TCP/IP

Transmission Control Protocol/Internet Protocol

TMN

Telecommunications Management Network

TRIB

Tributary

TS

Service telephone

Tx

Transmission

UHF

Ultra High Frequency

URG

Urgent

VCO

Voltage Controlled Oscillator

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

1-7

LA

PA
G
E

1 - PRELIMINARY INFORMATION

1-8

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2 PLANNING
2.1 SRAL XD FAMILY: THE EXTRA DENSITY
SYSTEM FOR MULTIPLE HIGH-SPEED
NETWORKS
In the last years microwave systems have covered most of connectivity needs especially
in the lower layers of the transmission networks consolidating its role of reliable,
easy-to-install and cost-effective access solution.
Siemens, used to be one of the frontrunners in this market segment, is ready to match
the expectations of this new telecommunication era characterized by broadband and
mobility convergence.
The new challenge launched by operators aim to increase link density and capacity per
link leaving spectrum occupancy practically unchanged. Siemens always ready to
acknowledge market indication and trends, adds to its extensive Microwave portfolio the
new line of point to point low capacity digital radio: SRAL XD.
SRAL XD is a member of Siemenss extensive telecommunication product portfolio.
Siemens expertise and catalogue cover most of the outstanding technologies which
current application are based on: switching, cellular technology, radio and networking,
voice and data over IP and ATM.
An outstanding turnkey project management capability, the ownership of a so wide
range of in-house product lines and a worldwide field proven experience, represents
Siemens business card.

A) APPLICATIONS
SRAL XD line is primarily designed for urban networks, but is also suitable in regional
networks meeting all the requirements of access and trunk applications.

Mobile Networks
3G Mobile ATM based collector network tipically conveying traffic from NodeBs to
Hub stations.
2G infrastructure network already implement SDH microwave rings to connect
access to core networks. In the next future, the overlay of the two networks will
certainly benefit from SRAL XD upgrading facilities rewarding operators with
flexible and versatile infrastructures.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-1

2 - PLANNING

Fixed services Networks


Support of ATM/IP networks, LAN and WAN.
A lot of applications are possible, particularly since voice and data can be
transmitted over the same microwave link. A typical scenario is an enterprise with
a branch office located at some distance from the main premise.
Service convergence is the word summarising the trend of this kind of networks,
and once again flexibility becomes a must even in this case.

B) COMPELLING FEATURES
Based on networks specific needs, the operator can select either higher spectrum
efficiency or higher system gain and hop lengths.
All the parameter can be SW selected locally or remotely in order to adapt the HW
platform to each single link characteristics in terms of available RF channel, payload,
usable bandwidth and hop lenght.
SRAL XD flexibility and versatility greatly improve all the upgrading procedures and
configuration change. A terminal can be easily relocated without any HW modification
simply re-shaping its peculiar parameters on the new link requirement.
Another important strong advantage is represented by the extreme compactness of
SRAL XD Indoor Unit. A single 44 mm high unit is necessary to implement any protected
or unprotected terminal configurations.
Station footprint is among the most troublesome matter for network planners, SRAL XD
minimise the impact of transmission on this matter following two different paths:
integrating the indoor card BTSs/ NodeBs for operators using Siemens integrated
solution and adopting a standard slim indoor unit for any terminal configurations (44 mm)
for any other applications.
The integrated solution provides BTS / Node B and transmission in the same shelf,
eliminating any additional room allocation for transmission systems.
Add and Drop and Crossconnection functionality enrich the set of SRAL XD features
eliminating the need of distribution frames in the station.
Any E1 stream plugged in the terminal A can be extracted from any E1 connectors of
the station B eliminating the need of bulky distribution frames.
Furthermore, always in a 44 mm high unit, the Add and Drop facility permits to drop the
E1 in a required station leaving the remaining streams passing untouched.
The features are the following:

2-2

7 to 38 GHz RF Bands coverage

2/4/8/16xE1, E3, 10/100 BaseT Traffic capacities

Normal/High Density Modulation formats

(1+0) / 2x(1+0) / (1+1)HSBy / (1+1)Frequency/

Polarization Diversity / Add Drop / Repeater

ATPC or Fixed attenuation setting

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

1U High IDU for protected and unprotected terminals

Fully SW downloadable

Fully configurable via SW: transmitted payload and RF operating channel

Single HW for all the capacity rates

Cross connect capability at E1 level

IP dynamic routing within controller

NMS channel add-drop

VoIP concept for voice service channel

C) SYSTEM ARCHITECTURE
The Split Configuration has been kept, even though both the IDU and the ODU have
been redesigned in order to reduce their mechanical dimensions.
In order to save room for the indoor installation, the dimensions of the IDU have been
dramatically reduced, moving the mo/demodulation section to the ODU.
As result the IDU, able to provide protect configuration, is only 1U high.
In spite of this change the dimensions of the ODU have been reduced as well by
adopting the state of the art technology.
Fig. 2.1

System architecture

Aggregated
Baseband Signal

Aggregated
Baseband Signal

1+1 Terminals

1+0 Terminals

Aggregated
Baseband Signal

Add and Drop


Terminals

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-3

2 - PLANNING

D) INDOOR UNITS
Three types of IDU are available:

Fig. 2.2

Plug-in IDU

Single board IDU

MinIDU

Plug-in IDU

Plug-in IDU

The 1U High Plug-In Version adopts a modular architecture:


The basic configuration (1+0) consist of a controller, an access card and a base-band
card; in order to arrange protected/add drop repeater configuration, an additional
base-band card has to be added in the same shelf. The Plug-In version is able to provide
a full set of configuration/interfaces.

Fig. 2.3

(1+0)/ (1+1) FD, HSBY/ 2x(1+0)/Add/Drop Repeater

2/16xE1/E3

Lan Bridge: 10/100 BaseT mapped on a 2Mbit stream

Single Board IDU

Single Board IDU

The 1U High Single Board IDU is based on a single board architecture characterised
by a fixed set of functionalities. Four versions are available:

2-4

Up to 8xE1 (1+0)

Up to 8xE1 (1+1) HSBy

Up to 16xE1 (1+0)

Up to 16xE1 (1+1) HSBy

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.4

MinIDU

MinIDU

The MinIDU, based on a monolithic architecture, is designed to be integrated in


Siemens NodeB and BTS shelter.
The indoor unit handles the traffic directly coming from the hosting BTS/NodeB without
any external cabling.
The MinIDU version is available in two different versions:

8xE1(1+0)

16xE1(1+0)/(1+1)FD,HSBY/ 2x(1+0)/Add/Drop Repeater

Each version, being independent of the modulation format, will manage either High or
Normal density

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-5

2 - PLANNING

E) OUTDOOR UNITS
State of art RF technology has been the baseline for SRAL XD ODUs development
completely matching all the technical constraints introduced by the high modulation
scheme adopted for the HD version: system linearity and synthesizer phase noise.
Two different outdoor units are part of SRAL XD suit:

Normal Density ODU


Provides only normal density channel arrangement (4 CPM Modulation Format)
and is able to assure a complete compatibility through the entire SRAL product
LINE

Fig. 2.5

Normal Density ODU

High Density/High Performance ODU:


Supports both normal and high density modulation schemes (4 QAM, 16 TCM
Modulation Format) assuring a SW selectable adaptation of SRAL XD terminals to
the available bandwidth.

Fig. 2.6

2-6

High Density/High Performance ODU

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.7

SRAL XD Suit Cross Compatibilities

Normal Density

High Performance/High Density


HP/HD ODU

ND ODU

MinIDU

Plug-in IDU

Single Board IDU

F) MANAGEMENT
For SRAL XD product line, system concept and the embedded software architecture
have been designed to permit a user-friendly and effective local and remote terminals
management. Communication protocols, physical interfaces, networking peculiarities
has been thought to simplify and speed up DCN implementation as much as possible.
SRAL XD, as all the Siemens microwave product lines, can be managed not only by a
wide range Siemens Management Systems, but also by third party Management
Systems.
Open interfaces are available to integrate SRAL XD and the complete Siemens
Microwave catalogue in multivendor transmission networks.
Scalability and modularity are the words better describing our Management Solutions:
NetViewer, TNMS Core or Radio Commander are the system can be used to manage
Siemens MW catalogue respectively when considered as stand alone, when managed
together with Siemens ADM/Crossconnect/LineTerminals or supervised by Siemens
Mobile Element Manager.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-7

2 - PLANNING

2.1.1

SRAL XD system described in this User Manual


In this User Manual is described the SRAL XD system operating at 7 GHz, 8 GHz,
15 GHz, 18 GHz, 23 GHz, 26 GHz, 28 GHz and 38 GHz with the Single Board IDU only
with the following traffic capacity:

2E1: in Base configuration

4E1: in Base configuration

8E1: in Base configuration

16E1: in Extension configuration

The 2 Mbit/s capacity, having the channel arrangement like the one of 2x2 Mbit/s
capacity, is derived from 2x2 Mbit/s option.
The equipment is available in the following configurations:

2.1.2

Base (1+0)

with Extension (1+1) H/S

System building
Fig. 2.8 shows the SRAL XD equipment block diagram.
The equipment has been realized by physically subdividing it into two assemblies: one
for outdoor installation (ODU) and one for indoor installation (IDU).
This subdivision allows:

the RF losses, due to the interconnection between ODU and the antenna, to be
minimized

a common IDU, for all the applications to be realized.

According to the configurations, one or two ODUs can be equipped.


The connection between IDU and ODU is made through a single coaxial cable.
It is possible to use antennas with diameter dependently of the hop lenght to be realized.
The ODU is available in two versions:

2-8

Normal Density (ND) able to perform traditional channel arrangements


2/4/8/16xE1 in 3.5/7/14/28 MHz via 4 CPM modulation format.

High Density/High Performance (HD/HP) able to perform both High Density


arrangements (8/16xE1 in 7/14 MHz), via 16 TCM modulation format, and Normal
Density arrangements (2/4/8/16xE1 in 3.5/7/14/28 MHz), via 4 QAM modulation
format. Normal Density arrangement performed by ODU HD/HP is named High
Performance since it provides improved system gain in comparison to ODU ND.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.8

SRAL XD equipment block diagram

Integrated antenna
F Interface
V-LAN Interface
Q-LAN Interface

Control and
supervision
signals and
channels

IDU-ODU
interconnection
(coaxial cable)

ALM Interface
IDU
E1 Interfaces
USER-1 Interface

ODU

Tributary
and
services
signals
(payload)

PS Interface

IDU-CABLE
interface

ODU-CABLE
interface

IDU Basic functions:

System interfacing to external world


Baseband digital signal processing
IDU-ODU cable interface management
(from/to ODU)
Supervision and configuration/management
of the equipment
Equipments power supply management

ANTENNA
interface

RF
interface

ODU Basic functions:

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

RSSI
interface

IDU-ODU cable interface management


Modulation of baseband digital signal (from
IDU)
Demodulation of the received RF signal (to
IDU)
Supervision and configuration/management
of the ODU
Management of comm. channel from/to IDU
CONTROLLER Section

2-9

2 - PLANNING

2.1.3

Network topologies
Possible topologies of the SRAL XD equipment are shown in Fig. 2.9, Fig. 2.10 and
Fig. 2.11.

Fig. 2.9

STAR topology (protected or unprotected links)

BSC

= BTS

Fig. 2.10

MULTIDROP topology (add/drop or back-to-back links)

BSC

Fig. 2.11

LOOP topology (add/drop or back-to-back links)

BSC

2-10

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.1.4

IDU-ODU Interconnection
The interconnection between the IDU and the ODU consists of only one two-way line
transporting one composite signal comprising the 51.84 Mbit/s IDU-ODU stream and of
the ODU power supply voltage.

2.1.4.1

51.84 Mbit/s signal


With regard to the transmission/reception of the 51.84 Mbit/s stream, the IDU-ODU link
consists of an active hybrid.
The active hybrid on the transmission path allows to forward the 51.84 Mbit/s stream to
the output i.e., either towards the ODU or towards the IDU. Afterwards, by means of the
properly connected operational amplifiers the cited signal will be suppressed on the
receive side (i.e., towards the unit proper).
The signal that has been received from the ODU (or from the IDU) is sent to the Receive
Circuits via the active hybrid.
A 128 kbit/s auxiliary channel is present on the 51.84 Mbit/s stream connecting the IDU
and the ODU. The channel also transports all the data necessary for the equipment to
operate properly (alarms, data channel, etc.).

2.1.4.2

ODU Power Supply


The IDU-ODU interconnection cable also transports the auxiliary DC voltage, required
to power the ODU, which is supplied by the internal DC/DC Converter. In the IDU are
also present the soft-start circuits, the current limitation circuit and the generation of the
open cable alarm or short-circuited cable alarm.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-11

2 - PLANNING

2.1.5

Physical interfaces
Refer to Fig. 2.12.

2.1.5.1

Power supply
The IDU makes available, at the outside, an input line for the connection of the power
supply batteries to the equipment.

2.1.5.2

Tributary signals
The IDU makes available at the outside (on the front panel of the IDU) 8 or 16 I/O lines
for the 2 Mbit/s tributaries as per G.703, with 75 Ohm unbalanced or 120 Ohm balanced
interface.

2.1.5.3

User channel
The IDU makes available, at the outside, a 64 kbit/s synchronous data channel (V.11)
for applications defined by the user.
The SRAL XD system only executes a point-to-point channel carrying and it is absolutely
transparent to the channel contents.
The user channel can be configured in two different modes:

Contradirectional: clock associated with the input data stream originated by the
IDU and it is delivered to an external equipment

Co-directional: clock associated with the input data stream originated by an


external equipment and delivered to the IDU.

The user channel configuration is an action controlled through software, carried out by
the Controller unit.

2.1.5.4

Alarm and remote control external lines


The IDU is provided with an alarm interface delivering to the outside some signal lines
associated with the two main functions:

2-12

transparent carrying, through the radio link, of up to 4 alarm/command lines


delivered to the outside (e.g., alarm of open door, smoke alarm, switching
commands, etc.)

sending of 7 output alarms relevant to the equipment status.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.1.5.5

Monitoring of received RF power on the ODU


The ODU has a monitoring point by which it is possible to measure the received radio
signal field.

Fig. 2.12

IDU physical interfaces


Control BUS

Power supply BUS

POWER
SUPPLY
Section

PS1

TRIBUTARY
Section

USER

E1

CONTROLLER
Section

V-LAN Q-LAN

ALM

Signal BUS

BASE-BAND
and
ADAPTER
Section

ADAPTER
Section

CABLE INT.

CABLE INT.

IDU-CABLE

IDU-CABLE

Used only in the HSBY


configuration

IDUs Interfaces

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-13

2 - PLANNING

2.1.6

Supervision interfaces
The following logical interfaces are available in order to allow complete networking
among different NEs of SRAL XD family:

F interface
The F interface is used to allow SRAL XD <--> LCT connection, i.e. the
connection among the SRAL XD type NE and the PC, which can be locally
connected to the equipment in order to perform supervision and configuration of
the local node. An example of F interface usage is shown in Fig. 2.13..

The F interface can also be used to extend a SRAL network with SRAL XD NE
as shown in station C in Fig. 2.13.

2-14

R interface
The R interface is used to allow SRAL XD <--> SRAL XD when the NEs are not
located in the same station and are the terminals of one radio link (i. e., only radio
connection is available among the NEs). The R interface is internal to the
equipment, and is not accessible to the user. An example of R interface usage is
shown in Fig. 2.13.

V-LAN interface
The V-LAN interface is used to allow SRAL XD <--> SRAL XD/SRAL XD
networking for supervision purposes, when the NEs are placed in the same
location and they are not terminals of the same radio link (i. e. only cable
connection is available among the NEs). Examples of V-LAN interface usage are
shown in Fig. 2.13.

Q-LAN interface
The Q-LAN interface:

is used to allow SRAL XD <--> SRAL XD/SRAL XD networking for


supervision purposes, when the NEs are placed in the same location and they
are not terminals of the same radio link (i. e. only cable connection is available
among the NEs) and V-LAN interface is not available (i.e., Q-LAN and
V-LAN permit daisy chaining of the TMN supervision channel);

is used to allow SRAL XD <--> TMN Operation Support System OSS direct
connection for supervision purposes.
Examples of Q-LAN interface usage are shown in Fig. 2.13.

D interface
The D interface is used to connect two NEs, which belong to disjoined radio
networks. An example of D interface usage is shown in Fig. 2.13. The D
interface is internal to the equipment, and is not accessible to the user.
The D channel of SRAL XD equipment is transmitted using a 64 kbit/s slot
selected among those of E1 tributary number #1 or transmitted in alternative to the
64 kbit/s user channel.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.13

Network supervision

SITE "B"
"F" interface
SITE "A"
"R" channel

"SRAL XD"
NE

"SRAL XD"
NE

V-LAN
interfaces

Q-LAN interfaces
"R" channel
"SRAL XD"
NE

"SRAL XD"
NE

"SRAL XD"
NE

V-LAN
Interfaces
"SRAL XD"
NE

F
interface

"SRAL XD"
NE

"D"
interface

SRA L
NE

Line
Terminal

SITE "C"

Cable
Connection

SITE "E"
"D" interface

"Q-LAN" interface

"SRAL XD"
NE

TMN OSS

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

"R" interface

Line
Terminal

"SRAL XD"
NE

"R" interface

SITE "D"

2-15

2 - PLANNING

2.1.7

Loop-backs
The following loop-backs are provided for maintenance purposes.

2.1.7.1

Fig. 2.14

Tributary loop-backs

Tributary loop-back

Local loop-back (A)


The tributary signal can be looped back in the base-band unit at the input interface
level.
This type of loop-back when activated allows testing the integrity of the circuitry
related to line interface access.

Remote loop-back (B)


Each tributary stream can be looped towards the remote station.
This type of loop-back when activated allows testing connection integrity between
two terminals.

Each available tributary (i.e., each enabled tributary) can be looped back either locally
or remotely using suitable software commands (test commands), issued via LCT or
OSS.

2-16

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.1.8

Configurations
The equipment configuration can be:

single terminal (1+0) 8 or 16xE1:

see Fig. 2.15 and Fig. 2.16

terminal with Hot-standby


protection (1+1) H/S 8 or 16xE1

see Fig. 2.17 and Fig. 2.18

The single terminal configuration 1+0 needs one IDU and the corresponding ODU.
The 1+1 H/S configuration needs two IDUs and is realised with one antenna (see Fig.
2.17).

Fig. 2.15

SRAL XD equipment: 1+0 configuration


USER
ALARM
CHANNEL
INT.

ODU
Rx

IDU Single Board


DEM
Cable
INT.

Tx

MOD

LIU
SECT. ADAPTER
SECT.
and
CABLE
INT.

BB
SECT.

TRIB.
8xE1
BASE
SECT.

TRIB.
2 Mbit/s (E1)

STATION
BATTERY

CONTROLLER
SECT.

V INT.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

F INT.

Q INT.

2-17

2 - PLANNING

Fig. 2.16

SRAL XD equipment: 16E1 (1+0) configuration


USER
ALARM
CHANNEL
INT.

ODU

IDU Single Board

Rx

DEM
Cable
INT.

Tx

MOD

LIU
SECT. ADAPTER
and
SECT.
CABLE
INT.

BB
SECT.

TRIB.
8xE1
BASE
SECT.

TRIB.
2 Mbit/s (E1)

TRIB.
8xE1
EXP
SECT.

TRIB.
2 Mbit/s (E1)

F INT.

CONTROLLER
SECT.

STATION
BATTERY

V INT.

Fig. 2.17

Q INT.

SRAL XD equipment: 8xE1 (1+1) H/S configuration with one antenna


USER
ALARM
CHANNEL
INT.

ODU 1
Rx

IDU Single Board

DEM
Cable
INT.

Tx

MOD

LIU
SECT.
and
CABLE
INT.

ADAPTER
SECT.

BB
SECT.

TRIB.
8xE1
BASE
SECT.

TRIB.
2 Mbit/s (E1)

STATION
BATTERY

CONTROLLER
SECT.

F INT.

ODU 2
Rx

DEM
Cable
INT.

Tx

MOD

LIU
SECT.
and
CABLE
INT.

V INT.

2-18

Q INT.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.18

SRAL XD equipment: 16xE1 (1+1) H/S with one antenna configuration


USER
ALARM
CHANNEL
INT.

ODU 1
Rx

IDU Single Board

DEM
Cable
INT.

Tx

MOD

LIU
SECT.
and
CABLE
INT.

BB
SECT.

ADAPTER
SECT.

TRIB.
8xE1
BASE
SECT.

TRIB.
2 Mbit/s (E1)

TRIB.
8xE1
EXP
SECT.

TRIB.
2 Mbit/s (E1)

STATION
BATTERY

ODU 2
Rx

DEM

Tx

MOD

Cable
INT.

LIU
SECT.
and
CABLE
INT.

V INT.

2.1.8.1

F INT.

CONTROLLER
SECT.

Q INT.

Licence fee
The actually available configurations depend on the enabled licence fee.
The individual licence fee configuration data of any system is stored and retrieved from
a dedicated memory key to be inserted in the IDU.
"Payload Type", "System Type" and "Channel Spacing" parameters are subjected to
licence fee.

2.1.8.2

Configuration summary
The next table shows all the configurations and system types.

Up to 16E1 (1+0)

Up to 8E1 (1+1) HSBY

Up to 16E1 (1+1) HSBY

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

High
Density

Normal
Density

1+1 HSBY

1+0

8xE1

Up to 8E1 (1+0)

16xE1

4xE1

Configuration summary
2xE1

IDU
Single Board

Tab. 2.1

2-19

2 - PLANNING

2.2 TECHNICAL CHARACTERISTICS


2.2.1

General characteristics

2-20

System type:

Base

Extended

(1+0)
(1+1) H/S with one antenna

Transmission capacity:

Base System

Extended System

22 Mbit/s, 42 Mbit/s, 82 Mbit/s,


162 Mbit/s

Gross bit rate of the transmitted signal:

22 Mbit/s (2xE1)
4.864 Mbit/s

42 Mbit/s (4xE1)
9.728 Mbit/s

82 Mbit/s (8xE1)
19.456 Mbit/s

162 Mbit/s (16xE1)


38.912 Mbit/s

Modulation:

2/2x2/4x2/8x2/16x2 Mbit/s (with ODU ND)


4 levels CPM

2/2x2/4x2/8x2/16x2 Mbit/s (with ODU HD/HP in HP mode) 4 levels QAM

8x2/16x2 Mbit/s (with ODU HD/HP in HD mode)


16 levels TCM

Demodulation:

non coherent with Reed Solomon FEC and Viterbi decoding (with ODU ND)

coherent with Reed Solomon FEC (with ODU HD/HP)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

RF bands:

RF Bands

7 GHz

7.1-7.9 GHz

Freq. Range
(GHz)

Tx/Rx Spacing
(MHz)

ITU-R

7.1 - 7.4

161 MHz

F.385

7.1 - 7.4

196 MHz

F.385 Annex 3

7.4 - 7.7

161 MHz

F.385

7.4 - 7.7

154 MHz

F.385 Annex 1

7.4 - 7.7

168 MHz

F.385 Annex 3

7.75 - 7.975

148.5 MHz

Bulgaria

7.4 - 7.9

245 MHz

F.385 Annex 4

7.7 - 8.2

311.25 MHz

F.386-6 Annex 1

8 GHz

7.7-8.5 GHz

8.275 - 8.5

126 MHz

F.386-6 Annex 3

8.275 - 8.5

119 MHz

F.386-6 Annex 3

13 GHz

12.75-13.25 GHz

12.75-13.25

266 MHz

F.497

14.40-15.35

420 MHz

F.636

14.40-15.35

490 MHz

F.636

14.40-15.35

728 MHz

F.636

14.40-15.35

322 MHz

F.636

14.40-15.35

336 MHz

F.636

14.40-15.35

315 MHz

F.636

17.7-19.7

1010 MHz

F.595

17.7-19.7

1560 MHz

F.595

17.7-19.7

340 MHz

F.595

22.0-23.6

1008 MHz

F.637Annex1

21.2-23.6

1232 MHz

F.637Annex1

21.2-23.6

1200 MHz

F.637Annex1

15 GHz

18 GHz

23 GHz

Operating limits

14.40-15.35 GHz

17.7-19.7 GHz

21.2-23.6 GHz

26 GHz

24.5-26.5 GHz

24.5-26.5

1008 MHz

F.748

28 GHz

27.5-29.5 GHz

27.5-29.5

1008 MHz

F.748 Annex 2

38 GHz

37.0-39.5 GHz

37.0 - 39.5

1260 MHz

F.749

Channel arrangement:

ODU ND
2x2 Mbit/s
4x2 Mbit/s
8x2 Mbit/s
16x2 Mbit/s

ODU HD/HP
HP Mode 2x2 Mbit/s
4x2 Mbit/s
8x2 Mbit/s
16x2 Mbit/s
HD Mode

8x2 Mbit/s
16x2 Mbit/s

3.5 MHz
7 MHz
14 MHz/13.75 MHz (Note 1)
28 MHz/27.5 MHz (Note 1)

3.5 MHz
7 MHz
14 MHz/13.75 MHz (Note 1)
28 MHz/27.5 MHz (Note 1)
7 MHz
14 MHz/13.75 (Note 1)

Note 1: 13.75 MHz and 27.5 MHz channelling is available for 18 GHz only.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-21

2 - PLANNING

System gain [dB]1:

BER<10-3
Typical
BER<10-6

BER<10-3
Guaranteed
BER<10-6

ODU ND
7
GHz

8
GHz

13
GHz

15
GHz

18
GHz

23
GHz

26
GHz

28
GHz

38
GHz

2xE1

ND

118.0

118.0

113.5

113.5

111.0

110.5

110.0

110.0

108.0

4xE1

ND

115.0

115.0

110.5

110.5

108.0

107.5

107.0

107.0

105.0

8xE1

ND

112.0

112.0

107.5

107.5

105.0

104.5

104.0

104.0

102.0

16xE1 ND

108.0

108.0

103.5

103.5

101.0

100.5

100.0

100.0

98.0

2xE1

ND

116.5

116.5

112.0

112.0

109.5

109.0

108.5

108.5

106.5

4xE1

ND

113.5

113.5

109.0

109.0

106.5

106.0

105.5

105.5

103.5

8xE1

ND

110.5

110.5

106.0

106.0

103.5

103.0

102.5

102.5

100.5

16xE1 ND

106.5

106.5

102.0

102.0

99.5

99.0

98.5

98.5

96.5

2xE1

ND

114.0

114.0

109.5

109.5

107.0

106.5

106.0

106.0

104.0

4xE1

ND

111.0

111.0

106.5

106.5

104.0

103.5

103.0

103.0

101.0

8xE1

ND

108.0

108.0

103.5

103.5

101.0

100.5

100.0

100.0

98.0

16xE1 ND

104.0

104.0

99.5

99.5

97.0

96.5

96.0

96.0

94.0

2xE1

ND

112.5

112.5

108.0

108.0

105.5

105.0

104.5

104.5

102.5

4xE1

ND

109.5

109.5

105.0

105.0

102.5

102.0

101.5

101.5

99.5

8xE1

ND

106.5

106.5

102.0

102.0

99.5

99.0

98.5

98.5

96.5

16xE1 ND

102.5

102.5

98.0

98.0

95.5

95.0

94.5

94.5

92.5

1. The values refer to a link with modulation index h=0.33. Should be used a smaller modulation index, the performances have to be reduced (i.e. to improve the
spectrum efficiency or to get BW99%=1CS).

2-22

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2xE1
4xE1
BER<10-3
8xE1
16xE1
Typical
2xE1
4xE1
BER<10-6
8xE1
16xE1
2xE1
4xE1
BER<10-3
8xE1
16xE1
Guaranteed
2xE1
4xE1
BER<10-6
8xE1
16xE1

ODU HD/HP
7
GHz

8
GHz

15
GHz

18
GHz

23
GHz

26
GHz

28
GHz

38
GHz

118.0

116.0

112.0

117.5

113.0

112.0

112.0

108.5

115.0

113.0

109.0

114.5

110.0

109.0

109.0

105.5

HP

112.0

110.0

106.0

111.5

107.0

106.0

106.0

102.5

HD

106.5

104.5

100.5

106.0

101.5

100.5

100.5

97.0

HP

109.0

97.0

103.0

108.5

104.0

103.0

103.0

99.5

HD

103.5

101.5

97.5

103.0

98.5

97.5

97.5

94.0

HP

116.5

114.5

110.5

116.0

111.5

110.5

110.5

107.0

113.5

111.5

107.5

113.0

108.5

107.5

107.5

104.0

HP

110.5

108.5

104.5

110.0

105.5

104.5

104.5

101.0

HD

105.0

103.0

99.0

104.5

100.0

99.0

99.0

95.5

HP

107.5

105.5

101.5

107.0

102.5

101.5

101.5

98.0

HD

102.0

100.0

96.0

101.5

97.0

96.0

96.0

92.5

HP

114.0

112.0

108.0

113.5

109.0

108.0

108.0

104.5

111.0

109.0

105.0

110.5

106.0

105.0

105.0

101.5

HP

108.0

106.0

102.0

107.5

103.0

102.0

102.0

98.5

HD

102.5

100.5

96.5

102.0

97.5

96.5

96.5

93.0

HP

105.0

103.0

99.0

104.5

100.0

98.0

98.0

95.5

HD

99.5

97.5

93.5

99.0

94.5

93.5

93.5

90.0

HP

112.5

110.5

106.5

112.0

107.5

106.5

106.5

103.0

109.5

107.5

103.5

109.0

104.5

103.5

103.5

100.0

HP

106.5

104.5

100.5

106.0

101.5

100.5

100.5

97.0

HD

101.0

99.0

95.0

100.5

96.0

95.0

95.0

91.5

HP

103.5

101.5

97.5

103.0

98.5

97.5

97.5

94.0

HD

98.0

96.0

92.0

97.5

93.0

92.0

92.0

88.5

HP
HD
HP
HD

HD
HP
HD

HD
HP
HD

HD
HP
HD

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-23

2 - PLANNING

Tuning range:

IDU-ODU interface:

Line code

Bit rate

B3ZS
51.84 Mb/s

Max IDU/ODU distance:

with coax. Braided cable

with coax 1/4 cable

200 m
300 m

IDU/ODU protection

refer to the ODU frequency tables in doc.


"Equipment composition"

according to IEC 1000-4-5, X level2,


criterion 2

2. X=10kV/p; 1.2/50 sec

2-24

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.2.2
2.2.2.1

ODU ND characteristics
Transmitter
The following characteristics refer to points set down in Fig. 2.19. Unless otherwise
stated, the RF parameters have to be understood having been measured at point C' and
valid for the temperature range defined in par. 2.2.8.

Fig. 2.19
Z

ETSI Block diagram of Tx RF side

A
TRANSMIT.

MOD

PTx_max
(dBm)

RF Tx
FILTER

BRANCHING
NETWORK

D
FEEDER

Max output power [dBm]:


7
GHz

8
GHz

13
GHz

15
GHz

18
GHz

23
GHz

26
GHz

28
GHz

38
GHz

typical

ND

24

24

20

20

18

18

18

18

17

guaranteed

ND

22

22

18

18

16

16

16

16

15

Output power adjustment [dB]:


7/8/13/15/18/23 GHz

26/28/38 GHz

0...24

0...20

from 2 to 3.5

from 2 to 3.5

Attenuation value [dB]:


a)

Accuracy [dB]

a. Varying the attenuation, the accuracy changes, with linear function.

ATPC range

Pmin to Pmax

ATPC threshold

software selectable

Output power in squelched condition


mode
-50 dBm (RBW=1MHz)

Tx frequency tolerance

5 ppm BOL (Beginning Of Life)


8 ppm EOL (End Of Life)

Tuning step

250 kHz

Output signal spectral power density:

22 Mbit/s (2xE1)

42 Mbit/s (4xE1)
see mask of Fig. 2.20

82 Mbit/s (8xE1)

162 Mbit/s (16xE1)

External spurious emission:

30 MHz - 21.2 GHz

21.2 GHz - 60 GHz

-50 dBm (RBW=1MHz)


-30 dBm (RBW=1MHz)

Return loss

16 dB

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-25

2 - PLANNING

Fig. 2.20

Mask of the RF signal for 7 GHz to 38 GHz ODU ND according to the traffic
capacity
+1
0

SPECTRAL
POWER
DENSITY
(Relevant to
peak power of
the signal)

H1

H2

F0

Tab. 2.2

2-26

Fa

Fb

Fc

Fd

Fe

RF signal attenuation limit values (7 GHz to 38 GHz - ND)


Traffic
capacity

Channel
spacing
(MHz)

2xE1

3,5

1.4

2.8

3.5

8.75

4xE1

2.7

5.6

6.5

13

17.5

8xE1

14 (13.75 for
18 GHz only)

5.4

11.2

13

26

35

16xE1

28 (27.5 for
18 GHz only)

11

19

25

45

70

Fa
Fb
Fc
Fd
Fe
(MHz) (MHz) (MHz) (MHz) (MHz)

H1
(dB)

H2
(dB)

-23

-45

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.2.2.2

Receiver
The following characteristics refer to the points set down in Fig. 2.21. Unless otherwise
stated, the RF parameters have to be understood as measures at point C and valid for
the temperature range defined in par. 2.2.8.

Fig. 2.21

ETSI Block diagram of Rx RF side

C
FEEDER

Typical
threshold
BER<10-6

BER<10-3
Guaranteed
threshold
BER<10-6

RF Rx
FILTER

E
RECEIVER

Max. input power (BER 10-11)

-20 dBm

Max. input power to prevent from


permanent damaging

-10 dBm

BER<10-3

BRANCHING
NETWORK

Z
DEM

Rx thresholds [dBm]3):
7
GHz

8
GHz

13
GHz

15
GHz

18
GHz

23
GHz

26
GHz

28
GHz

38
GHz

2xE1

ND

-94.0

-94.0

-93.5

-93.5

-93.0

-92.5

-92.0

-92.0

-91.0

4xE1

ND

-91.0

-91.0

-90.5

-90.5

-90.0

-89.5

-89.0

-89.0

-88.0

8xE1

ND

-88.0

-88.0

-87.5

-87.5

-87.0

-86.5

-86.0

-86.0

-85.0

16xE1 ND

-84.0

-84.0

-83.5

-83.5

-83.0

-82.5

-82.0

-82.0

-81.0

2xE1

ND

-92.5

-92.5

-92.0

-92.0

-91.5

-91.0

-90.5

-90.0

-89.5

4xE1

ND

-89.5

-89.5

-89.0

-89.0

-88.5

-88.0

-87.5

-87.0

-86.5

8xE1

ND

-86.5

-86.5

-86.0

-86.0

-85.5

-85.0

-84.5

-84.0

-83.5

16xE1 ND

-82.5

-82.5

-82.0

-82.0

-81.5

-81.0

-80.5

-80.0

-79.5

2xE1

ND

-92.0

-92.0

-91.5

-91.5

-91.0

-90.5

-90.0

-90.0

-89.0

4xE1

ND

-89.0

-89.0

-88.5

-88.5

-88.0

-87.5

-87.0

-87.0

-86.0

8xE1

ND

-86.0

-86.0

-85.5

-85.5

-85.0

-84.5

-84.0

-84.0

-83.0

16xE1 ND

-82.0

-82.0

-81.5

-81.5

-81.0

-80.5

-80.0

-80.0

-79.0

2xE1

ND

-90.5

-90.5

-90.0

-90.0

-89.5

-89.0

-88.5

-88.5

-87.5

4xE1

ND

-87.5

-87.5

-87.0

-87.0

-86.5

-86.0

-85.5

-85.5

-84.5

8xE1

ND

-84.5

-84.5

-84.0

-84.0

-83.5

-83.0

-82.5

-82.5

-81.5

16xE1 ND

-80.5

-80.5

-80.0

-80.0

-79.5

-79.0

-78.5

-78.5

-77.5

3. The Rx Threshold Values given in the table are referred to SRAL XD like modulation index (Bandwidth 99% > 1CS).
The values are 1 dB less, if different modulation index (Bandwidth 99% 1CS)
is used.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-27

2 - PLANNING

2.2.3
2.2.3.1

ODU HD/HP characteristics


Transmitter
The following characteristics refer to points set down in Fig. 2.19. Unless otherwise
stated, the RF parameters have to be understood having been measured at point C' and
valid for the temperature range defined in par. 2.2.8.

Fig. 2.22
Z

ETSI Block diagram of Tx RF side

A
TRANSMIT.

MOD

PTx_max
(dBm)

typical
guaranteed

Attenuation value [dB]

RF Tx
FILTER

BRANCHING
NETWORK

D
FEEDER

Max output power [dBm]:


7 GHz

8 GHz

15 GHz 18 GHz 23 GHz 26 GHz 28 GHz 38 GHz

HP

23

22

20

24

20

20

20

17

HD

18

17

15

19

15

15

15

12

HP

21

20

18

22

18

18

18

15

HD

16

15

13

17

13

13

13

10

Output power adjustment [dB]:


7 GHz

8 GHz

15 GHz 18 GHz 23 GHz 26 GHz 28 GHz 38 GHz

HP

0-19

0-18

0-20

0-20

0-15

0-18

0-18

0-20

HD

0-14

0-13

0-15

0-15

0-10

0-13

0-13

0-15

a)

from 2 to 3.5

Accuracy [dB]

a. Varying the attenuation, the accuracy changes, with linear function.

2-28

ATPC range

Pmin + software selectable ATPC range

ATPC threshold

software selectable

Output power squelched condition


mode

-50 dBm (RBW=1MHz)

Tx frequency tolerance

5 ppm BOL (Beginning Of Life)


8 ppm EOL (End Of Life)

Tuning step

250 kHz

Output signal spectral power density:

22 Mbit/s (2xE1)

42 Mbit/s (4xE1)
see mask of Fig. 2.23 - HP mode

82 Mbit/s (8xE1)
see mask of Fig. 2.24-Fig. 2.25 - HD mode

162 Mbit/s (16xE1)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.23

External spurious emission:

30 MHz - 21.2 GHz

21.2 GHz - 60 GHz

-50 dBm (RBW=1MHz)


-30 dBm (RBW=1MHz)

Return loss

16 dB

Mask of the RF signal for 7 GHz to 38 GHz ODU (HP mode) according to the traffic
capacity
+1
0

SPECTRAL
POWER
DENSITY
(Relevant to
peak power of
the signal)

H1

H2

F0

Tab. 2.3

Fa

Fb

Fc

Fd

Fe

RF signal attenuation limit values (7 GHz to 38 GHz - HP)


Traffic
capacity

Channel
spacing
(MHz)

2xE1

3.5

1.4

2.8

3.5

8.75

4xE1

2.7

5.6

6.5

13

17.5

8xE1

14 (13.75 for
18 GHz only)

5.4

11.2

13

26

35

16xE1

28 (27.5 for
18 GHz only)

11

19

25

45

70

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

Fa
Fb
Fc
Fd
Fe
(MHz) (MHz) (MHz) (MHz) (MHz)

H1
(dB)

H2
(dB)

-23

-45

2-29

2 - PLANNING

Fig. 2.24

Mask of the RF signal for 23, 26, 28 and 38 GHz ODU (HD mode) according to the
traffic capacity
+1
0

SPECTRAL
POWER
DENSITY
(Relevant to
peak power of
the signal)

H1
H2

H3

F0

Tab. 2.4

2-30

Fa

Fb

Fc

Fd

Fe

RF signal attenuation limit values (23, 26, 28 and 38 GHz - HD)


Traffic
capacity

Channel
spacing
(MHz)

2xE1

1.75

n.a.

n.a.

n.a.

n.a.

n.a.

4xE1

3.5

n.a.

n.a.

n.a.

n.a.

n.a.

8xE1

2.8

5.6

12.25

17.5

16xE1

14

5.6

11.2

14

24.5

35

Fa
Fb
Fc
Fd
Fe
(MHz) (MHz) (MHz) (MHz) (MHz)

H1
(dB)

H2
(dB)

H3
(dB)

-30

-35

-50

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.25

Mask of the RF signal for 7, 8, 15 and 18 GHz ODU (HD mode) according to the
traffic capacity

+1
0

SPECTRAL
POWER
DENSITY
(Relevant to
peak power of
the signal)

H1
H2

H3

F0

Tab. 2.5

Fa

Fb

Fc

Fd

Fe

RF signal attenuation limit values (7, 8, 15 and 18 GHz - HD)


Traffic
capacity

Channel
spacing
(MHz)

2xE1

1.75

n.a.

n.a.

n.a.

n.a.

n.a.

4xE1

3.5

n.a.

n.a.

n.a.

n.a.

n.a.

8xE1

2.8

5.6

14

17.5

16xE1

14

5.6

11.2

14

28

35

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

Fa
Fb
Fc
Fd
Fe
(MHz) (MHz) (MHz) (MHz) (MHz)

H1
(dB)

H2
(dB)

H3
(dB)

-32

-37

-55

2-31

2 - PLANNING

2.2.3.2

Receiver
The following characteristics refer to the points set down in Fig. 2.21. Unless otherwise
stated, the RF parameters have to be understood as measures at point C and valid for
the temperature range defined in par. 2.2.8.

Fig. 2.26

ETSI Block diagram of Rx RF side

C
FEEDER

RF Rx
FILTER

E
RECEIVER

Max. input power


(BER 10-9 without FEC)

-20 dBm

Max. input power to prevent from


permanent damaging

-10 dBm

Z
DEM

Rx thresholds [dBm]4):

2xE1
4xE1
BER<10-3
8xE1
16xE1

Typical
threshold

BRANCHING
NETWORK

2xE1
4xE1
BER<10-6
8xE1
16xE1

7
GHz

8
GHz

15
GHz

18
GHz

23
GHz

26
GHz

28
GHz

38
GHz

-95.0

-94.0

-92.0

-93.5

-93.0

-92.0

-92.0

-91.5

-92.0

-91.0

-89.0

-90.5

-90.0

-89.0

-89.0

-88.5

HP

-89.0

-88.0

-86.0

-87.5

-87.0

-86.0

-86.0

-85.5

HD

-88.5

-87.5

-85.5

-87.0

-86.5

-85.5

-85.5

-85.0

HP

-86.0

-85.0

-83.0

-84.5

-84.0

-83.0

-83.0

-82.5

HD

-85.5

-84.5

-82.5

-84.0

-83.5

-82.5

-82.5

-82.0

HP

-93.5

-92.5

-90.5

-92.0

-91.5

-90.5

-90.5

-90.0

-90.5

-89.5

-87.5

-89.0

-88.5

-87.5

-87.5

-87.0

HP

-87.5

-86.5

-84.5

-86.0

-85.5

-84.5

-84.5

-84.0

HD

-87.0

-86.0

-84.0

-85.5

-85.0

-84.0

-84.0

-83.5

HP

-84.5

-83.5

-81.5

-83.0

-82.5

-81.5

-81.5

-81.0

HD

-84.0

-83.0

-81.0

-82.5

-82.0

-81.0

-81.0

-80.5

HP
HD
HP
HD

HD
HP
HD

cont.

4. The Rx Threshold Values given in the table are referred to SRAL XD like modulation index (Bandwidth 99% > 1CS).
The values are 1 dB less, if different modulation index (Bandwidth 99% = 1CS)
is used.

2-32

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2xE1
4xE1
BER<10-3
8xE1
16xE1

Guarantee
d threshold

2xE1
4xE1
BER<10-6
8xE1
16xE1

7
GHz

8
GHz

15
GHz

18
GHz

23
GHz

26
GHz

28
GHz

38
GHz

-93.0

-92.0

-90.0

-91.5

-91.0

-90.0

-90.0

-89.5

-90.0

-89.0

-87.0

-88.5

-88.0

-87.0

-87.0

-86.5

HP

-87.0

-86.0

-84.0

-85.5

-85.0

-84.0

-84.0

-83.5

HD

-86.5

-85.5

-83.5

-85.0

-84.5

-83.5

-83.5

-83.0

HP

-84.0

-83.0

-81.0

-82.5

-82.0

-81.0

-81.0

-80.5

HD

-83.5

-82.5

-80.5

-82.0

-81.5

-80.5

-80.5

-80.0

HP

-91.5

-90.5

-88.5

-90.0

-89.5

-88.5

-88.5

-88.0

-88.5

-87.5

-85.5

-87.0

-86.5

-85.5

-85.5

-85.0

HP

-85.5

-84.5

-82.5

-84.0

-83.5

-82.5

-82.5

-82.0

HD

-85.0

-84.0

-82.0

-83.5

-83.0

-82.0

-82.0

-81.5

HP

-82.5

-81.5

-79.5

-81.0

-80.5

-79.5

-79.5

-79.0

HD

-82.0

-81.0

-79.0

-80.5

-80.0

-79.0

-79.0

-78.5

HP
HD
HP
HD

HD
HP
HD

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-33

2 - PLANNING

2.2.4
2.2.4.1

IDU characteristics
Operating mode

2.2.4.2

2.2.4.4

revertive/unrevertive

Hardware alarm detection time

2.2.4.3

Switch hardware logic


in hot standby configuration

Failure alarm

1 ms

Operational switching time

Tx RF switch for hot-stand-by

< 50 ms

Rx total recovery time (failures)

< 300 ms (maximum value)


< 100 ms (typical value)

Characteristics of 2 Mbit/s tributary interface (E1)


The tributary interface can be 75 Ohm or 120 Ohm.

Bit rate

2048 kbit/s 50 ppm

Code

HDB3

Pulse shape

see Fig. 2.27

Load impedance

75 Ohm o 120 Ohm

Nominal peak voltage of


a mark (pulse):

75 Ohm

120 Ohm

2.37 V
3V

Nominal peak voltage of


a "space" (no pulse)

75 Ohm

120 Ohm

0 0.237 V
0 0.3 V

Nominal pulse length

244 ns

Output return loss

10 dB,
for f = 51.2 to 3072 kHz

Input return loss:

f = 51 to 102 kHz

f = 102 to 2048 kHz

f = 2048 to 3072 kHz

2-34

18 dB
22 dB
18 dB

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.27

Shape of 2 Mbit/s tributary interface output signal

NOMINAL
PULSE

2.2.4.5

Characteristics of channel auxiliary interfaces


LCT channel

Channel type

19.2 kbit/s asynchronous data channel

Electrical interface5)

RS-232C

V-LAN

Channel type

IEEE 802.3

Electrical interface

10BASE-T

User channel

Channel type6)

64 kbit/s synchronous data channel

Electrical interface

V.11

5. The IDU is considered as DCE.


6. The user channel can be configured (by software) as codirectional or
counter-directional.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-35

2 - PLANNING

D7) channel (external)

Channel type

64 kbit/s synchronous data channel

Electrical interface

V.11

Q-LAN

Channel type

IEEE 802.3 and 802.3U

Electrical interface

10/100BASE-T

Electrical alarms interface

Input/Output lines

Input lines:

OPEN criterion

CLOSED criterion

Output lines

OPEN criterion

Potential

2.2.4.6

-3V to +2V voltage to ground with 60 kohm


series
-3V to +2V voltage to ground with 200 ohm
series

negative/positive to ground (from external


source)
72V
0.1 mA

CLOSED criterion

Potential

Max. voltage
Max. sinking current

OPEN/CLOSED criteria

negative/positive to ground (from external


source)
Max. voltage
72V
Max. continuous current 60 mA
Residual voltage
(on the contact)
2V

Surge immunity

accord. to IEC 1000-4-5, Class 3, criterion 2

Power supply characteristics

Input voltage range

-38.4V to -57.6V

Automatic power-up voltage

-37.5V 0.5V

Automatic shutdown voltage

-36.5V 0.5V

Protection against reversal of


battery polarity

yes

Maximum current load @ minimum


input voltage
4.5A

Inrush current during equipment


start-up

10A

Surge immunity

accord. to IEC 1000-4-5, Class 3, criterion 2

7. The external D channel is alternative to the user channel.

2-36

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.2.5

2.2.6

Guaranteed consumptions

IDU 1+0 8xE1

9W

IDU 1+1 16xE1

11 W

ODU ND

22 W

ODU HD/HP

40 W

Temperature range

2.2.7

IDU

Guaranteed performances

Exceptional operating
conditions
ODU

Guaranteed performances

Exceptional operating
conditions

-5C to +45C (see Fig. 2.28)


-10C to +50C (see Fig. 2.29)
-30C to +55C (see Fig. 2.28)
-35C to +60C (see Fig. 2.29)

Mechanical characteristics
The IDU can be arranged for the installation, by means of two different supporting
brackets, in standard ETSI or 19" racks.
The max. IDU overall dimensions are:

height

44 mm (standard 19")

width

533 mm

depth

243.5 mm

weight (full equipped)

2 kg

The ODU is arranged for pole mounting. On customer request, it can be delivered with
the antenna.
The ND ODU and HD/HP ODU mechanical characteristics are:
(ND) ODU

(HD/HP) ODU

height

267 mm

--

width

281 mm

290 mm

depth

123 mm

164 mm

weight

4.3 kg

7.5 kg

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-37

2 - PLANNING

2.2.8

Environmental conditions
The equipment complies with ETSI ETS 300 019 Rec. (Feb. 1992).
IDU meets the following ETSI classes:

Transport

ETS 300 019-1-2 Class 2.3

Stationary utilization

ETS 300 019-1-3 Class 3.2

Storage

ETS 300 019-1-1 Class 1.3

the temperature/humidity characteristics excepted, for which the climatic diagram of


Fig. 2.28 and Fig. 2.30 is valid.
ODU meets the following ETSI classes:

Transport

ETS 300 019-1-2 Class 2.3

Stationary utilization

ETS 300 019-1-4 Version 2.1.2 Class 4.2H

Storage

ETS 300 019-1-1 Class 1.3

the temperature/humidity characteristics excepted, for which the climatic diagram of


Fig. 2.29 and Fig. 2.30.
Fig. 2.28

Temperature/humidity climatic diagram for IDU

AIR
TEMPERATURE
C

RELATIVE AIR
HUMIDITY %
GUARANTEED PERFORMANCES

2-38

EXCEPTIONAL OPERATING
CONDITIONS

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.29

Temperature/humidity climatic diagram for ODU

AIR
TEMPERATURE
C

GUARANTEED
PERFORMANCES

Fig. 2.30

RELATIVE AIR
HUMIDITY %

EXCEPTIONAL OPERATING
CONDITIONS

Temperature/humidity climatic diagram for IDU-ODU storage

AIR
TEMPERATURE
C

GUARANTEED
PERFORMANCES

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

RELATIVE AIR
HUMIDITY %

EXCEPTIONAL OPERATING
CONDITIONS

2-39

2 - PLANNING

2.2.9

EMC/EMI characteristics
Each external interface satisfies the following EMC/EMI requirements save that's
otherwise declared into the relevant paragraph.

Electrostatic discharge

RF electromagnetic field
(80-1000 MHz)

accord. to IEC 1000-4-3, Level 2, criterion 1

Electrical Fast Transient/


Burst (EFT/B) immunity

accord. to IEC 1000-4-4, Level 3, criterion 1

Surge immunity

accord. to IEC 1000-4-5, Class 2, criterion 2

Radio frequency common mode


(0.15-80 MHz)

accord. to IEC 1000-4-6, Level 2, criterion 1

Conducted emission

according to EN 55022, Class B

Radiated emission

according to EN 55022, Class B

Safety

according to IEC 950, Class I

Shock and Vibration

according to ETS 300 019-1-3


ETS 300 019-2-3 Test condition T3.2

according to IEC 1000-4-2, Level 2 (contact)


Level 3 (air ), criterion 1

N.B.:

2-40

criterion 1: no degradation of normal performance ( no errors )

criterion 2: degradation of normal performance / loss of functionality, with auto


recovery

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.3 EQUIPMENT COMPOSITION


This document lists and shows the "main parts" the SRAL XD equipment consists of.
"Main parts" are those autonomous units, from a structural viewpoint, which form part of
the SRAL XD equipment assemblies and are extractable from the assemblies
themselves.
The SRAL XD equipment comprises an indoor assembly (IDU), arranged for being
installed in a 19" or ETSI rack, and one or two outdoor assemblies (ODU); upon request,
the equipment is delivered with the antenna (one or two, according to the configuration).
The ODU and the antenna are arranged for mounting on a special supporting frame
fixed to the pole.
Two possible installation modes of the antenna-ODU assembly are possible:

integrated mode: ODU and antenna installed on the same supporting frame and
directly connected

separated mode: ODU and antenna installed on two different supporting frames
and connected through connection in wave-guide.

The connection between the indoor (IDU) assy. and the outdoor (ODU) assy. is carried
out by means of a coaxial cable.

2.3.1

System configurations
For the SRAL XD equipment the configurations (system types) are provided as listed in
Tab. 2.6 and shown in Fig. 2.31, Fig. 2.32, Fig. 2.33, Fig. 2.34 and Fig. 2.35.

Tab. 2.6

System configurations for SRAL XD equipment


System type
1+0
1+1 H/S

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

Denomination

Ref.

(1+0) single terminal

Fig. 2.31 and Fig. 2.32

(1+1) H/S terminal with 1 antenna

Fig. 2.33, Fig. 2.34


and Fig. 2.35

2-41

2 - PLANNING

2.3.2

SRAL XD equipment composition (7 GHz P/N 832-042/07)


In Tab. 2.7 and Tab. 2.8 is set down the composition of the SRAL XD equipment (7.1 to
7.9 GHz) for the different provided configurations.

Tab. 2.7

SRAL XD equipment composition [7 GHz in 1+0 configuration]


Ref. Fig.
2.31, 2.32
A
B

Q.ty
max.

Denomination
IDU (Single Board)

ODU (7 GHz) HD/HP


Independent antenna

732-101/71x
732-241/07

ODU (7 GHz) ND

732-251/07
Refer to Tab. 2.25

Integrated antenna - 60 cm

601-060/07

Integrated antenna - 120 cm

Tab. 2.8

601-120/07

ODU support frame

534-108/69

IDU-ODU interconnection
coaxial cable

Refer to Cap. 3
"INSTALLATION"

Kit for ODU separated mount

Refer to Cap. 3
"INSTALLATION"

Note
4
1
2
1
3

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

Provided for the pole installation of the ODU in case of ODU-antenna separated
installation.

4.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD equipment composition [7 GHz in 1+1 H/S configuration with 1 antenna]


Ref. Fig.
2.33
A
B

Q.ty
max.

Denomination
IDU (Single Board)

ODU (7 GHz) HD/HP

ODU (7 GHz) ND
Independent antenna

P/N
732-101/71x
732-241/07
732-251/07
Refer to Tab. 2.25

Integrated antenna - 60 cm

Integrated antenna - 120 cm

2-42

P/N

601-060/07
601-120/07

ODU support frame for 1+1 H/S

534-108/82

IDU-ODU interconnection
coaxial cable

Refer to Cap. 3
"INSTALLATION"

Note
3
1
2
1
1

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.3.3

SRAL XD equipment composition (8 GHz P/N 832-042/08)


In Tab. 2.9 and Tab. 2.10 is set down the composition of the SRAL XD equipment (7.7
to 8.2 GHz) for the different provided configurations.

Tab. 2.9

SRAL XD equipment composition [8 GHz in 1+0 configuration]


Ref. Fig.
2.31, 2.32
A
B

Denomination
IDU (Single Board)
ODU (8 GHz) HD/HP
ODU (8 GHz) ND

Q.ty
max.
1

732-101/71x
732-241/08

732-251/08

Independent antenna
C

Integrated antenna - 60 cm

Refer to Tab. 2.25


1

601-060/07

Integrated antenna - 120 cm

Tab. 2.10

P/N

601-120/07

ODU support frame

534-108/69

IDU-ODU interconnection
coaxial cable

Refer to Cap. 3
"INSTALLATION"

Kit for ODU separated mount

Refer to Cap. 3
"INSTALLATION"

Note
4
1
2
1
3

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

Provided for the pole installation of the ODU in case of ODU-antenna separated
installation.

4.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD equipment composition [8 GHz in 1+1 H/S configuration with 1 antenna]


Ref. Fig.
2.33
A
B

Denomination
IDU (Single Board)
ODU (8 GHz) HD/HP
ODU (8 GHz) ND

Q.ty
max.
1
2

Independent antenna
C

Integrated antenna - 60 cm

P/N
732-101/71x
732-241/08
732-251/08
Refer to Tab. 2.25

Integrated antenna - 120 cm

601-060/07
601-120/07

ODU support frame for 1+1 H/S

534-108/83

IDU-ODU interconnection
coaxial cable

Refer to Cap. 3
"INSTALLATION"

Note
3
1
2
1
1

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-43

2 - PLANNING

2.3.4

SRAL XD equipment composition (13 GHz P/N 832-042/13)


In Tab. 2.11 and Tab. 2.12 is set down the composition of the SRAL XD 13 equipment
(12.75 to 13.25 GHz) for the different provided configurations.

Tab. 2.11

SRAL XD equipment composition [13 GHz in 1+0 configuration]


Ref. Fig.
2.31, 2.32

Denomination

Q.ty
max.

IDU (Single Board)

732-101/71x

ODU (13 GHz) ND

732-251/13

Independent antenna

2-44

P/N

Note
4

Refer to Tab. 2.25

Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

601-060/13
601-080/13
601-120/13

ODU support frame

534-108/71

IDU-ODU interconnection
coaxial cable

Refer to Cap. 3
"INSTALLATION"

Kit for ODU separated mount

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

Provided for the pole installation of the ODU in case of ODU-antenna separated
installation.

4.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.12

SRAL XD equipment composition [13 GHz in 1+1 H/S configuration] with 1


antenna
Ref. Fig.
2.34, 2.35

Denomination

Q.ty
max.

P/N

IDU (Single Board)

732-101/71x

ODU (13 GHz) ND

732-251/13

Independent antenna

Note
3

Refer to Tab. 2.25

Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

601-060/13
601-080/13
601-120/13

1+1 H/S ODU support frame

534-108/85

IDU-ODU interconnection
coaxial cable

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-45

2 - PLANNING

2.3.5

SRAL XD equipment composition (15 GHz P/N 832-042/15)


In Tab. 2.13 and Tab. 2.14 is set down the composition of the SRAL XD 15 equipment
(14.40 to 15.35 GHz) for the different provided configurations.

Tab. 2.13

SRAL XD equipment composition [15 GHz in 1+0 configuration]


Ref. Fig.
2.31, 2.32
A
B

Q.ty
max.

Denomination
IDU (Single Board)

ODU (15 GHz) ND

ODU (15 GHz) HD/HP


Independent antenna

2-46

Integrated antenna 30 cm
Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

P/N
732-101/71x
732-251/15
732-241/15

Note
4
1

Refer to Tab. 2.25

601-030/15
601-060/15
601-080/15
601-120/15

1
3

ODU support frame

534-108/72

IDU-ODU interconnection coaxial


cable

Refer to Cap. 3
"INSTALLATION"

Kit for ODU separated mount

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

Provided for the pole installation of the ODU in case of ODU-antenna separated
installation.

4.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.14

SRAL XD equipment composition [15 GHz in 1+1 H/S configuration] with 1


antenna

Ref. Fig.
2.34, 2.35
A
B

Denomination
IDU (Single Board)
ODU (15 GHz) ND
ODU (15 GHz) HD/HP

Q.ty
max.
1
2

Independent antenna
C

Integrated antenna 30 cm
Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

P/N
732-101/71x
732-251/15
732-241/15

Note
3
1

Refer to Tab. 2.25

601-030/15
601-060/15
601-080/15
601-120/15

ODU bal. support frame (integrated antenna)


ODU unbal. support frame (integrated antenna)
ODU bal. support frame (independent antenna)
ODU unbal. support frame (independent antenna)

534-120/11
534-120/01
534-121/11
534-121/01

IDU-ODU interconnection coaxial cable

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-47

2 - PLANNING

2.3.6

SRAL XD equipment composition (18 GHz P/N 832-042/18)


In Tab. 2.15 and Tab. 2.16 is set down the composition of the SRAL XD 18 equipment
(17.7 to 19.7 GHz) for the different provided configurations.

Tab. 2.15

SRAL XD equipment composition [18 GHz in 1+0 configuration]


Ref. Fig.
2.31, 2.32

Q.ty
max.

Denomination

Note

IDU (Single Board)

732-101/71x

ODU (18 GHz) HD/HP


ODU (18 GHz) ND

732-241/18
732-251/18

Refer to Tab. 2.25

601-030/18
601-060/18
601-080/18
601-120/18

1
3

Independent antenna
C

2-48

P/N

Integrated antenna 30 cm
Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

ODU support frame

534-108/73

IDU-ODU interconnection coaxial


cable

Refer to Cap. 3
"INSTALLATION"

Kit for ODU separated mount

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

Provided for the pole installation of the ODU in case of ODU-antenna separated
installation.

4.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.16

SRAL XD equipment composition [18 GHz in 1+1 H/S configuration] with 1


antenna

Ref. Fig.
2.34, 2.35

Denomination

Q.ty
max.

P/N

Note

IDU (Single Board)

732-101/71x

ODU (18 GHz) HD/HP


ODU (18 GHz) ND

732-241/18
732-251/18

Refer to Tab. 2.25

601-030/18
601-060/18
601-080/18
601-120/18

Independent antenna
C

Integrated antenna 30 cm
Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

ODU bal. support frame (integrated antenna)


ODU unbal. support frame (integrated antenna)
ODU bal. support frame (independent antenna)
ODU unbal. support frame (independent antenna)

534-120/12
534-120/02
534-121/12
534-121/02

IDU-ODU interconnection coaxial cable

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-49

2 - PLANNING

2.3.7

SRAL XD equipment composition (23 GHz P/N 832-042/23)


In Tab. 2.17 and Tab. 2.18 is set down the composition of the SRAL XD 23 equipment
(21.2 to 23.6 GHz) for the different provided configurations.

Tab. 2.17

SRAL XD equipment composition [23 GHz in 1+0 configuration]


Ref. Fig.
2.31, 2.32

P/N

Note

IDU (Single Board)

732-101/71x

ODU (23 GHz) HD/HP


ODU (23 GHz) ND

732-241/23
732-251/23

Independent antenna

Refer to Tab. 2.25

Integrated antenna 20 cm
Integrated antenna 30 cm
Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

601-020/23
601-030/23
601-060/23
601-080/23
601-120/23

2-50

Q.ty
max.

Denomination

ODU support frame

534-108/73

IDU-ODU interconnection coaxial


cable

Refer to Cap. 3
"INSTALLATION"

Kit for ODU separated mount

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

Provided for the pole installation of the ODU in case of ODU-antenna separated
installation.

4.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.18

SRAL XD equipment composition [23 GHz in 1+1 H/S configuration] with 1


antenna

Ref. Fig.
2.34, 2.35

Denomination

Q.ty
max.

P/N

Note

IDU (Single Board)

732-101/71x

ODU (23 GHz) HD/HP


ODU (23 GHz) ND

732-241/23
732-251/23

Refer to Tab. 2.25

601-030/23
601-060/23
601-080/23
601-120/23

Independent antenna
C

Integrated antenna 30 cm
Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

ODU bal. support frame (integrated antenna)


ODU unbal. support frame (integrated antenna)
ODU bal. support frame (independent antenna)
ODU unbal. support frame (independent antenna)

534-120/13
534-120/03
534-121/13
534-121/03

IDU-ODU interconnection coaxial cable

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-51

2 - PLANNING

2.3.8

SRAL XD equipment composition (26 GHz P/N 832-042/23)


In Tab. 2.19 and Tab. 2.20 is set down the composition of the SRAL XD 26 equipment
(24.5 to 26.5 GHz) for the different provided configurations.

Tab. 2.19

SRAL XD equipment composition [26 GHz in 1+0 configuration]


Ref. Fig.
2.31, 2.32

P/N

Note

IDU (Single Board)

732-101/71x

ODU (26 GHz) HD/HP


ODU (26 GHz) ND

732-241/26
732-251/26

Independent antenna

Refer to Tab. 2.25

Integrated antenna 20 cm
Integrated antenna 30 cm
Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

601-020/26
601-030/26
601-060/26
601-080/26
601-120/26

2-52

Q.ty
max.

Denomination

ODU support frame

534-108/73

IDU-ODU interconnection coaxial


cable

Refer to Cap. 3
"INSTALLATION"

Kit for ODU separated mount

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

Provided for the pole installation of the ODU in case of ODU-antenna separated
installation.

4.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.20

SRAL XD equipment composition [26 GHz in 1+1 H/S configuration] with 1


antenna

Ref. Fig.
2.34, 2.35

Denomination

Q.ty
max.

P/N

Note

IDU (Single Board)

732-101/71x

ODU (26 GHz) HD/HP


ODU (26 GHz) ND

732-241/26
732-251/26

Refer to Tab. 2.25

601-030/26
601-060/26
601-080/26
601-120/26

Independent antenna
C

Integrated antenna 30 cm
Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

ODU bal. support frame (integrated antenna)


ODU unbal. support frame (integrated antenna)
ODU bal. support frame (independent antenna)
ODU unbal. support frame (independent antenna)

534-120/14
534-120/04
534-121/14
534-121/04

IDU-ODU interconnection coaxial cable

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-53

2 - PLANNING

2.3.9

SRAL XD equipment composition (28 GHz P/N 832-042/28)


In Tab. 2.21 and Tab. 2.22 is set down the composition of the SRAL XD 28 equipment
(37.5 to 39.5 GHz) for the different provided configurations.

Tab. 2.21

SRAL XD equipment composition [28 GHz in 1+0 configuration]


Ref. Fig.
2.31, 2.32
A
B

2-54

Q.ty
max.

Denomination
IDU (Single Board)

ODU (28 GHz) HD/HP

ODU (28 GHz) ND

P/N
732-101/71x
732-241/28
732-251/28

Note
4
1

Independent antenna

Refer to Tab. 2.25

Integrated antenna 20 cm
Integrated antenna 30 cm
Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

601-020/28
601-030/28
601-060/28
601-080/28
601-120/28

ODU support frame

534-108/74

IDU-ODU interconnection coaxial


cable

Refer to Cap. 3
"INSTALLATION"

Kit for ODU separated mount

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

Provided for the pole installation of the ODU in case of ODU-antenna separated
installation.

4.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.22

SRAL XD equipment composition [28 GHz in 1+1 H/S configuration] with 1


antenna

Ref. Fig.
2.34, 2.35
A
B

Denomination
IDU (Single Board)
ODU (28 GHz) HD/HP
ODU (28 GHz) ND

Q.ty
max.
1
2

Independent antenna
C

Integrated antenna 30 cm
Integrated antenna 60 cm
Integrated antenna 80 cm
Integrated antenna 120 cm

P/N
732-101/71x
732-241/28
732-251/28

Note
3
1

Refer to Tab. 2.25

601-030/28
601-060/28
601-080/28
601-120/28

ODU bal. support frame (integrated antenna)


ODU unbal. support frame (integrated antenna)
ODU bal. support frame (independent antenna)
ODU unbal. support frame (independent antenna)

534-120/15
534-120/05
534-121/15
534-121/05

IDU-ODU interconnection coaxial cable

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-55

2 - PLANNING

2.3.10

SRAL XD equipment composition (38 GHz P/N 832-042/38)


In Tab. 2.23 and Tab. 2.24 is set down the composition of the SRAL XD/38 equipment
(37.5 to 39.5 GHz) for the different provided configurations.

Tab. 2.23

SRAL XD equipment composition [38 GHz in 1+0 configuration]


Ref. Fig.
2.31, 2.32

Q.ty
max.

Denomination

Note

IDU (Single Board)

732-101/71x

ODU (38 GHz) HD/HP


ODU (38 GHz) ND

732-241/38
732-251/38

Refer to Tab. 2.25

Independent antenna

2-56

P/N

Integrated antenna 20 cm
Integrated antenna 30 cm
Integrated antenna 60 cm

601-020/38
601-030/38
601-060/38

ODU support frame

534-108/74

IDU-ODU interconnection coaxial


cable

Refer to Cap. 3
"INSTALLATION"

Kit for ODU separated mount

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

Provided for the pole installation of the ODU in case of ODU-antenna separated
installation.

4.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.24

SRAL XD equipment composition [38 GHz in 1+1 H/S configuration] with 1


antenna

Ref. Fig.
2.34, 2.35

Denomination

Q.ty
max.

P/N

Note

IDU (Single Board)

732-101/71x

ODU (38 GHz) HD/HP


ODU (38 GHz) ND

732-241/38
732-251/38

Refer to Tab. 2.25

601-020/38
601-030/38
601-060/38

Independent antenna
C

Integrated antenna 20 cm
Integrated antenna 30 cm
Integrated antenna 60 cm

ODU bal. support frame (integrated antenna)


ODU unbal. support frame (integrated antenna)
ODU bal. support frame (independent antenna)
ODU unbal. support frame (independent antenna)

534-120/16
534-120/06
534-121/16
534-121/06

IDU-ODU interconnection coaxial cable

Refer to Cap. 3
"INSTALLATION"

1.

P/N in alternative.

2.

Along with the antenna, the pole fixing accessories and antenna-ODU supporting
frame are delivered.

3.

x = A, B, C or D according to the HW composition; see par. 2.3.13.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-57

2 - PLANNING

2.3.11
Tab. 2.25

Antenna P/N
Antenna P/N
Antenna Diameter (m)

Frequency Band
(GHz)

0.2

0.3

0.6

0.8

1.2

PDR 84

PDR 84

13

PBR 120

15

PBR 140

18

PBR 220

23

PBR 220

26

PBR 220

28

PBR 320

38

PBR 320

Feeder flange

Antennas P/N: 601-xxx/yy


Frequency
Diameter
Fix part
Example: 38 GHz diameter 0.6 m antenna

2-58

P/N 601-060/38

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.31

1+0 system with 1 integrated antenna (Terminal)

G
A

Tx5

Tx1

Tx9

Rx5

Rx1

Tx13

Rx9

USER/Dext

USER/Dext

ODU CABLE

Rx13

Q-LAN
ALMs

LCT
'

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

C
H
A

C
H
B

C
B
L

O
D
U

'

PS

SRAL XD
V-LAN
T
E
S
T

M
N
/
W

C
/
M
J

2-59

2 - PLANNING

Fig. 2.32

1+0 system with 1 independent antenna (Terminal)

B
F

Tx1

Tx5

Rx1

Tx9

Rx5

Tx13

Rx9

ODU CABLE

Rx13

Q-LAN
ALMs

USER/Dext

USER/Dext

LCT
'

2-60

C
H
A

C
H
B

C
B
L

O
D
U

'

PS

SRAL XD
V-LAN
T
E
S
T

M
N
/
W

C
/
M
J

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.33

SRAL XD - 7/8 GHz: 1+1 H/S system with 1 independent antenna (Terminal)

G
A

Tx1

Tx5

Rx1

Tx9

Rx5

Tx13

Rx9

Rx13

Q-LAN
ALMs

USER/Dext

USER/Dext

LCT
'

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

ODU CABLE

C
H
A

C
H
B

C
B
L

O
D
U

ODU CABLE

C
H
A

C
H
B

C
B
L

O
D
U

'

PS

SRAL XD
V-LAN
T
E
S
T

M
N
/
W

C
/
M
J

'

PS

2-61

2 - PLANNING

Fig. 2.34

SRAL XD - 15 to 38 GHz: 1+1 H/S system with 1 integrated antenna (Terminal)

B
G

Tx1

Tx5

Rx1

Tx9

Rx5

Tx13

Rx9

Rx13

Q-LAN
ALMs

USER/Dext

USER/Dext

LCT
'

2-62

ODU CABLE

C
H
A

C
H
B

C
B
L

O
D
U

'

ODU CABLE

C
H
A

C
H
B

C
B
L

O
D
U

'

PS

SRAL XD
V-LAN
T
E
S
T

M
N
/
W

C
/
M
J

PS

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.35

SRAL XD - 15 to 38 GHz: 1+1 H/S system with 1 independent antenna (Terminal)

Tx1

Tx5

Rx1

Tx9

Rx5

Tx13

Rx9

Rx13

Q-LAN
ALMs

USER/Dext

USER/Dext

ODU CABLE

C
H
A

C
H
B

C
B
L

O
D
U

ODU CABLE

C
H
A

C
H
B

C
B
L

O
D
U

'

PS

SRAL XD
V-LAN
LCT
'

T
E
S
T

M
N
/
W

C
/
M
J

'

PS

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-63

2 - PLANNING

2.3.12

Supporting frame

2.3.12.1

1+0 supporting frame


The 1+0 supporting frame consists of a mechanical structure, and relevant waveguide
accessories, suitable for pole or wall mounting of the Outdoor Unit in 1+0 configuration.
From an electrical point of view the frame is a passive device (i.e. waveguide section)
that provides interconnection between its two ports with negligible inssrtion loss.

Fig. 2.36

1+0 supporting frame

ODU
Waveguide

Tab. 2.26

2-64

Frame

1+0 supporting frame


Code

Freq.
Band
(GHz)

Freq.
Range
(GHz)

W.G.
Type

Port A
Flange
type

Port B
Flange
type

534-108/69

7.1 - 7.9

WR112 R84

UDR84

PDR84

534-108/69

7.7 - 8.5

WR112 R84

UDR84

PDR84

534-108/71

13

12.75-13.25

WR 75 R120

UBR120

PBR120

534-108/72

15

14.4 - 15.35

WR62 R140

UBR140

PBR140

534-108/73

18

17.7 - 19.7

WR42 R220

UBR220

PBR220

534-108/73

23

21.2 - 23.6

WR42 R220

UBR220

PBR220

534-108/73

26

24.5 - 26.5

WR42 R220

UBR220

PBR220

534-108/74

28

27.5 - 29.5

WR28 R320

UBR320

PBR320

534-108/74

38

37.5 - 39.5

WR28 R320

UBR320

PBR320

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.3.12.2

1+1 Supporting frame for Hot stand-by with integrated antenna


The 1+1 supporting frame for Hot Stand-by consists of a mechanical structure, and
relevant waveguide accessories, suitable for pole or wall mounting of the Outdoor Unit
in 1+1 HSBY (Hot Stand-by) unbalanced or balanced configuration.
From an electrical point of view the 1+1 frame is a balanced or unbalanced coupler. The
signal incoming from the antenna port is split unbalanced-wise the two ODUs.

Fig. 2.37

1+1 Supporting frame for Hot stand-by


B

ODU

A
B

ODU

Tab. 2.27

Coupler

Frame

1+1 Supporting frame for Hot stand-by with integrated antenna

Code

Freq.
Band
(GHz)

Freq.
Range
(GHz)

Coupler
type

Guide type

Port A
Flange
type

Port B
Flange
type

Coupling
(dB)

Insertion
loss
(dB)

534-120/01

15

14.4-15.35

unbal.

WR62 R140

UBR140

UBR140

< 11

< 1.3

534-120/11

15

14.4-15.35

bal.

WR62 R140

UBR140

UBR140

< 3.3

< 3.3

534-120/02

18

17.7-19.7

unbal.

WR42 R220

UBR220

UBR220

< 11

< 1.3

534-120/12

18

17.7-19.7

bal.

WR42 R220

UBR220

UBR220

< 3.3

< 3.3

534-120/03

23

21.2-23.6

unbal.

WR42 R220

UBR220

UBR220

< 11

< 1.3

534-120/13

23

21.2-23.6

bal.

WR42 R220

UBR220

UBR220

< 3.3

< 3.3

534-120/04

26

24.5-26.5

unbal.

WR28 R320

UBR320

UBR320

< 11

< 1.3

534-120/14

26

24.5-26.5

bal.

WR28 R320

UBR320

UBR320

< 3.3

< 3.3

534-120/05

28

27.5-29.5

unbal.

WR28 R320

UBR320

UBR320

< 11

< 1.3

534-120/15

28

27.5-29.5

bal.

WR28 R320

UBR320

UBR320

< 3.3

< 3.3

534-120/06

38

37.5-39.5

unbal.

WR28 R320

UBR320

UBR320

< 11

< 1.3

534-120/16

38

37.5-39.5

bal.

WR28 R320

UBR320

UBR320

< 3.3

< 3.3

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-65

2 - PLANNING

2.3.12.3

1+1 Supporting frame for Hot stand-by with independent antenna


The 1+1 supporting frame for Hot Stand-by consists of a mechanical structure, and
relevant waveguide accessories, suitable for pole or wall mounting of the Outdoor Unit
in 1+1 HSBY (Hot Stand-by) unbalanced or balanced configuration.
From an electrical point of view the 1+1 frame is a balanced or unbalanced coupler. The
signal incoming from the antenna port is split unbalanced-wise the two ODUs.

Fig. 2.38

1+1 Supporting frame for Hot stand-by


B

ODU

A
B

ODU

Tab. 2.28

Coupler

Frame

1+1 Supporting frame for Hot stand-by with independent antenna

Code

Freq.
Band
(GHz)

Freq.
Range
(GHz)

Coupler
type

Guide type

Port A
Flange
type

Port B
Flange
type

Coupling
(dB)

Insertion
loss
(dB)

534-108/82

7.1-7.9

unbal.

WR112 R84

UDR84

PDR84

8.5-11.5

<1

534-108/83

7.7-8.5

unbal.

WR112 R84

UDR84

PDR84

8.5-11.5

<1

534-108/85

13

12.75-13.25

unbal.

WR75 R120

UBR120

PBR120

8.5-11.5

< 1.1

534-121/01

15

14.4-15.35

unbal.

WR62 R140

UBR140

UBR140

< 11

< 1.3

534-121/11

15

14.4-15.35

bal.

WR62 R140

UBR140

UBR140

< 3.3

< 3.3

534-121/02

18

17.7-19.7

unbal.

WR42 R220

UBR220

UBR220

< 11

< 1.3

534-121/12

18

17.7-19.7

bal.

WR42 R220

UBR220

UBR220

< 3.3

< 3.3

534-121/03

23

21.2-23.6

unbal.

WR42 R220

UBR220

UBR220

< 11

< 1.3

534-121/13

23

21.2-23.6

bal.

WR42 R220

UBR220

UBR220

< 3.3

< 3.3

534-121/04

26

24.5-26.5

unbal.

WR28 R320

UBR320

UBR320

< 11

< 1.3

534-121/14

26

24.5-26.5

bal.

WR28 R320

UBR320

UBR320

< 3.3

< 3.3

534-121/05

28

27.5-29.5

unbal.

WR28 R320

UBR320

UBR320

< 11

< 1.3

534-121/15

28

27.5-29.5

bal.

WR28 R320

UBR320

UBR320

< 3.3

< 3.3

534-121/06

38

37.5-39.5

unbal.

WR28 R320

UBR320

UBR320

< 11

< 1.3

534-121/16

38

37.5-39.5

bal.

WR28 R320

UBR320

UBR320

< 3.3

< 3.3

2-66

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.3.13

IDU composition (Single Board)


The Single Board IDU (P/N 732-101/71) consists of a wired sub-rack (P/N 628-586/26),
where all the Single Board units are housed.
The sub-rack is delivered with two types of brackets to allow to be secured to 19" or ETSI
racks.
The IDU is available in 4 versions (Refer to Fig. 2.39, Fig. 2.40, Fig. 2.41 and Fig. 2.42):

732-101/71A - 1+0 - 8 x E1 - 75/120 ohm (SUB-D)

732-101/71C - 1+0 - 16 x E1 - 75/120 ohm (SUB-D)

732-101/71G - 1+1 - 8 x E1 - 75/120 ohm (SUB-D)

732-101/71E - 1+1 - 16 x E1 - 75/120 ohm (SUB-D)

Fig. 2.39

1+0/8xE1 Single Board IDU front view - P/N 732-101/71A

Fig. 2.40

1+0/16xE1 Single Board IDU front view - P/N 732-101/71C

Fig. 2.41

1+1/8xE1 Single Board IDU front view - P/N 732-101/71G

Fig. 2.42

1+1/16xE1 Single Board IDU front view - P/N 732-101/71E

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-67

2 - PLANNING

2.3.13.1

Licence fees
The Licence key" (P/N 625-017/xxx) includes a memory, called "Memory Key",
configured with the Licence required by the Customer. The last digits of the P/N describe
the configurations enabled on the equipment, according to the Tab. 2.29.

Tab. 2.29

2-68

Licence key P/Ns


P/N

System type

ODU

Capacity

625-017/31A

1+0

ND

4x2 Mbit/s

625-017/31B

1+0

ND

8x2 Mbit/s

625-017/31C

1+0

ND

16x2 Mbit/s

625-017/31D

1+0

HD

8x2 Mbit/s

625-017/31E

1+0

HD

16x2 Mbit/s

625-017/31F

1+1

ND

4x2 Mbit/s

625-017/31G

1+1

ND

8x2 Mbit/s

625-017/31H

1+1

ND

16x2 Mbit/s

625-017/31L

1+1

HD

8x2 Mbit/s

625-017/31M

1+1

HD

16x2 Mbit/s

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.3.13.2

Upgrading kits for on-field upgrading of the licence types


The "Upgrading kit" (P/N 625-018/11 xxxx) includes a "Program Hardware Key",
equipped with Licence Credits.
Tab. 2.30 lists the list of the available upgrading kit.

Tab. 2.30

Upgrading kit P/Ns


P/N

Upgrading type

625-018/11A100Q

KIT FOR CAPACITY EXP. FROM 4E1 TO 8E1 (1 NE)

625-018/11A200Q

KIT FOR CAPACITY EXP. FROM 8E1 TO 16E1 (1 NE)

625-018/11A300Q

KIT FOR CAPACITY EXP. FROM 4E1 TO 16E1 (1 NE)

625-018/11A010Q

KIT FOR EXP. FROM (1+0) TO (1+1) (1 NE)

625-018/11A001Q

KIT FOR EXP. FROM HP TO HD (1 NE)

625-018/11B100Q

KIT FOR CAPACITY EXP. FROM 4E1 TO 8E1 (2 NEs)

625-018/11B200Q

KIT FOR CAPACITY EXP. FROM 8E1 TO 16E1 (2 NEs)

625-018/11B300Q

KIT FOR CAPACITY EXP. FROM 4E1 TO 16E1 (2 NEs)

625-018/11B010Q

KIT FOR EXP. FROM (1+0) TO (1+1) (2 NEs)

625-018/11B001Q

KIT FOR EXP. FROM HP TO HD (2 NEs)

625-018/11C100Q

KIT FOR CAPACITY EXP. FROM 4E1 TO 8E1 (10 NEs)

625-018/11C200Q

KIT FOR CAPACITY EXP. FROM 8E1 TO 16E1 (10 NEs)

625-018/11C300Q

KIT FOR CAPACITY EXP. FROM 4E1 TO 16E1 (10 NEs)

625-018/11C010Q

KIT FOR EXP. FROM (1+0) TO (1+1) (10 NEs)

625-018/11C001Q

KIT FOR EXP. FROM HP TO HD (10 NEs)

625-018/11D100Q

KIT FOR CAPACITY EXP. FROM 4E1 TO 8E1 (50 NEs)

625-018/11D200Q

KIT FOR CAPACITY EXP. FROM 8E1 TO 16E1 (50 NEs)

625-018/11D300Q

KIT FOR CAPACITY EXP. FROM 4E1 TO 16E1 (50 NEs)

625-018/11D010Q

KIT FOR EXP. FROM (1+0) TO (1+1) (50 NEs)

625-018/11D001Q

KIT FOR EXP. FROM HP TO HD (50 NEs)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-69

2 - PLANNING

2.3.14

Connection accessories

2.3.14.1

Standard installation materials with 75 ohm tributaries

Tab. 2.31

Standard installation materials with 75 ohm tributaries


Configuration

P/N

Description

8xE1

16xE1

1+0

1+1

1+0

1+1

1xM

2xM

1xM

2xM

1xM

1xM

1xM

1xM

1xM

1xM

2xM

2xM

1xN

2xN

1xN

2xN

Connection kits
597-525/16

IDU connection kit


Cable

103-037/50
105-013/02

YE-GR PVC 1x16 mm grounding cable


2

2x1.5 mm bipolar shielded cable


Tributary prewiring cable (standard)

314-331/35 or

8xE1 75 ohm Tributary cable L = 5 m

314-331/36 or

8xE1 75 ohm Tributary cable L = 10 m

314-331/37 or

8xE1 75 ohm Tributary cable L = 20 m

314-331/38

8xE1 75 ohm Tributary cable L = 30 m


Tributary NO-prewiring cable (on request)

332-005/57

Tributary connection kit

104-102/23

16 coaxial cable
IN/OUT connections

104-009/5..

50 ohm Braided coaxal cable

597-525/59

50 ohm Braided coaxial cable accessories

M = Requested length, typical 5 m.


N = Requested length, the length of one IDU/ODU connection is 200 m max.

2-70

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.3.14.2

Standard installation materials with 120 ohm

Tab. 2.32

Standard installation materials with 120 ohm tributaries


Configuration

P/N

Description

8xE1

16xE1

1+0

1+1

1+0

1+1

1xM

2xM

1xM

2xM

1xM

1xM

1xM

1xM

1xM

1xM

2xM

2xM

1xN

2xN

1xN

2xN

Connection kits
597-525/16

IDU connection kit


Cable

103-037/50
105-013/02

YE-GR PVC 1x16 mm grounding cable


2

2x1.5 mm bipolar shielded cable


Tributary prewiring cable (standard)

314-331/79 or

8xE1 120 ohm Tributary cable L = 5 m

314-331/80 or

8xE1 120 ohm Tributary cable L = 10 m

314-331/81 or

8xE1 120 ohm Tributary cable L = 20 m

314-331/82

8xE1 120 ohm Tributary cable L = 30 m


Tributary NO-prewiring cable (on request)

332-005/57

Tributary connection kit

104-041/25

16 pair double shield cable


IN/OUT connections

104-009/5..

50 ohm Braided coaxal cable

597-525/59

50 ohm Braided coaxial cable accessories

M = Requested length, typical 5 m.


N = Requested length, the length of one IDU/ODU connection is 200 m max.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-71

2 - PLANNING

2.3.14.3

Optional installation materials

Tab. 2.33

Alarm connection
P/N

Denomination

332-055/49A

Alarms Connector

106-001/61

Tab. 2.34

8 Pairs Double Shield Cable

5m

Data channel connection


P/N

Denomination

332-055/29A

Q.ty

User/Dext connector

106-001/61

Tab. 2.35

Q.ty

8 Pairs Double Shield Cable

10 m

LAN connection
P/N

Denomination

Q.ty/Note

314-324/54

Cable of Cross Screened

q.ty n-1 (n=IDU equipment of daisy


chain)

422-053/63

RJ45 Connector

106-041/76

LAN Cable (cat. 5)

for each LAN connection


q.ty to be define

2.3.14.3.1 Installation materials composition


Tab. 2.36

IDU connection kit - P/N 597-525/16


P/N

Composition

332-055/28

Q.ty

Power Supply Accessories

422-060/16

DM Connector 3s AP

422-027/31

HP Female Contact

422-030/82

45 Metallic Shell for Sub-D 15c

314-303-56

Ground Cable

314-205/76

Installation Kit

223-009/16

Cable tie for internal L=280mm (1.777)

20

215-031/70

Uninsulated tube term. 6.4 for 16mm cable

203-343/15D

Stainless steel screw M6x22

207-510/11D

Stainless steel washer 6

207-501/11D

Stainless steel spring washer 6

206-702/14D

Stainless steel hex nut 6

Cable tie for external L=508mm (74140)

Metal Label

223-009/27
216-42/102

2-72

Denomination

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.37

Tributary connection kit - P/N 332-055/57


P/N

Tab. 2.38

Denomination

422-062/89

Sub-D Connector 50c S

422-058/81

50 Metallic Shell for Sub-D 50c

422-059/16

Locking screw

Alarm connector composition: P/N 332-055/49A


P/N

Tab. 2.39

Denomination

Q.ty

422-062/86

Sub-D Connector 15c S

422-030/92

45 Shielded Shell for Sub-D 15c

422-059/16

Locking screw

User/Dext connector composition: P/N 332-055/29A


P/N

Tab. 2.40

Q.ty

Denomination

Q.ty

422-062/60

Sub-D Connector 9c S

422-030/91

45 Shielded Shell for Sub-D 9c

422-059/16

Locking screw

(IN/OUT) 50 ohm Braided coaxial cable and ANDREW accessories set


P/N

Denomination

Q.ty

104-009/50
314-331/88 (b)

Braided CNT300 - 50 ohm coaxial


cable PNCNT300FR

(c)

597-525/59A
597-525/59 (b)

Braided coax cable accessories

(d)

421-025/30

90 COAXIAL SMA-PLUG

300APSR-C

421-008/35

90 COAXIAL N-PLUG

300APNR-C

333-031/21

GROUNDING KIT

KMT 7-P

b = Commercial reference
c = The max length of the IDU/ODU connection is 200 meters.
d = Q.ty 1 for each IDU/ODU connection.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-73

2 - PLANNING

Tab. 2.41

(IN/OUT) 50 ohm Braided coaxial cable and INTERCOND accessories set


P/N

Denomination

104-009/51
314-331/88 (b)

Braided CNT300 - 50 ohm COAXIAL


CABLE

597-525/59B
597-525/59 (b)

Braided COAX CABLE ACCESSORIES

Q.ty
PN14-RBC48/11M

(c)
(d)

421-025/31

90 COAXIAL SMA-PLUG

050-611-9129310

421-008/36

90 COAXIAL N-PLUG

057-011-9099890

333-031/22

GROUNDING KIT

2A48EOL-ICN/DS

b = Commercial reference
c = The max length of the IDU/ODU connection is 200 meters.
d = Q.ty 1 for each IDU/ODU connection.

2-74

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.3.15

ODU identification
The ODU comprises a hermetic container, arranged for pole fixing, inside which RF
modules (depending of the operating range), Modem and power supply modules
(common in all RF range) are housed.
Adjustment and composition of ODU RF units depend on the working RF frequency
range.
The ODU is available in HD/HP and ND versions:

HD/HP version:

P/N 732-241/07 : 7 GHz version (refer to par. 2.3.15.1)

P/N 732-241/08 : 8 GHz version (refer to par. 2.3.15.2)

P/N 732-241/15 : 15 GHz version (refer to par. 2.3.15.3)

P/N 732-241/18 : 18 GHz version (refer to par. 2.3.15.4)

P/N 732-241/23 : 23 GHz version (refer to par. 2.3.15.5)

P/N 732-241/26 : 26 GHz version (refer to par. 2.3.15.6)

P/N 732-241/28 : 28 GHz version (refer to par. 2.3.15.7)

P/N 732-241/38 : 38 GHz version (refer to par. 2.3.15.8)

ND version:

P/N 732-251/07 : 7 GHz version (refer to par. 2.3.15.9)

P/N 732-251/08 : 8 GHz version (refer to par. 2.3.15.10)

P/N 732-251/13 : 13 GHz version (refer to par. 2.3.15.11)

P/N 732-251/15 : 15 GHz version (refer to par. 2.3.15.12)

P/N 732-251/18 : 18 GHz version (refer to par. 2.3.15.13)

P/N 732-251/23 : 23 GHz version (refer to par. 2.3.15.14)

P/N 732-251/26 : 26 GHz version (refer to par. 2.3.15.15)

P/N 732-251/28 : 28 GHz version (refer to par. 2.3.15.16)

P/N 732-251/38 : 38 GHz version (refer to par. 2.3.15.17)

The ODU identification P/N comprises two field: the first one (11 characters) is the
equipment P/N, the second one (3 characters) is the customizing encoding, concerning
the RF frequency (operating frequency band within the whole RF range).
In Tab. 2.42 to Tab. 2.91 the frequency tables are shown.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-75

2 - PLANNING

2.3.15.1

7 GHz ODU HD/HP

Tab. 2.42

ODU (7.4 - 7.7 GHz) composition; Fs=154 MHz


7.4 - 7.7 GHz

FREQUENCY SHIFTER - 154 MHz (first digit Ext.= 0)


ODU
P/N

732-241/07

Ext.

Rx FREQ.
(MHz)

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Annex 1

Diplexer filter
P/N

Ext.

002

7582

- 7617

7428 - 7463

250

004

7589

- 7624

7435 - 7470

251

006

7596

- 7631

7442 - 7477

252

008

7603

- 7638

7449 - 7484

253

010

7610

- 7645

7456 - 7491

254

012

7617

- 7652

7463 - 7498

255

014

7624

- 7659

7470 - 7505

256

016

7631

- 7666

7477 - 7512

257

018

7638

- 7673

7484 - 7519

258

020

7645

- 7680

7491 - 7526

259

022

7652

- 7687

7498 - 7533

260

024

7659

- 7694

7505 - 7540

261

026

7666

- 7701

7512 - 7547

262

028

7673

- 7708

7519 - 7554

263

030

7680

- 7715

7526 - 7561

264

032

7687

- 7722

7533 - 7568

001

7428

- 7463

7582 - 7617

003

7435

- 7470

7589 - 7624

251

005

7442

- 7477

7596 - 7631

252

007

7449

- 7484

7603 - 7638

253

009

7456

- 7491

7610 - 7645

254

011

7463

- 7498

7617 - 7652

255

013

7470

- 7505

7624 - 7659

256

015

7477

- 7512

7631 - 7666

257

017

7484

- 7519

7638 - 7673

258

019

7491

- 7526

7645 - 7680

259

021

7498

- 7533

7652 - 7687

260

023

7505

- 7540

7659 - 7694

261

025

7512

- 7547

7666 - 7701

262

027

7519

- 7554

7673 - 7708

263

029

7526

- 7561

7680 - 7715

264

031

7533

- 7568

7687 - 7722

265

620-015/51

620-015/70
(732-241/07R1)

527-705/35

Mounting
type

Standard(*)
(A)

265
250

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-76

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.43

ODU (7.1 - 7.4 GHz) composition; Fs=161 MHz


7.1 - 7.4 GHz

FREQUENCY SHIFTER - 161 MHz (first digit Ext.= 1)


ODU
Rx FREQ. (MHz)
P/N

732-241/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Reference: Rec. ITU-R 385-7


Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

102

7285.5

7320.5 7124.5 - 7159.5

350

104

7292.5

7327.5 7131.5 - 7166.5

351

106

7299.5

7334.5 7138.5 - 7173.5

352

108

7306.5

7341.5 7145.5 - 7180.5

353

110

7313.5

7348.5 7152.5 - 7187.5

354

112

7320.5

7355.5 7159.5 - 7194.5

355

114

7327.5

7362.5 7166.5 - 7201.5

356

116

7334.5

7369.5 7173.5 - 7208.5

357

118

7341.5

7376.5 7180.5 - 7215.5

358

120

7348.5

7383.5 7187.5 - 7222.5

359

122

7355.5

7390.5 7194.5 - 7229.5

360

124

7362.5

7397.5 7201.5 - 7236.5

361

126

7369.5

7404.5 7208.5 - 7243.5

362

128

7376.5

7411.5 7215.5 - 7250.5

363

130

7383.5

7418.5 7222.5 - 7257.5

364

101

7124.5

620-015/70
7425.5 7229.5 - 7264.5
620-015/51
(732-241/07R1)
7159.5 7285.5 - 7320.5

103

7131.5

7166.5 7292.5 - 7327.5

351

105

7138.5

7173.5 7299.5 - 7334.5

352

107

7145.5

7180.5 7306.5 - 7341.5

353

109

7152.5

7187.5 7313.5 - 7348.5

354

111

7159.5

7194.5 7320.5 - 7355.5

355

113

7166.5

7201.5 7327.5 - 7362.5

356

115

7173.5

7208.5 7334.5 - 7369.5

357

117

7180.5

7215.5 7341.5 - 7376.5

358

119

7187.5

7222.5 7348.5 - 7383.5

359

121

7194.5

7229.5 7355.5 - 7390.5

360

123

7201.5

7236.5 7362.5 - 7397.5

361

125

7208.5

7243.5 7369.5 - 7404.5

362

127

7215.5

7250.5 7376.5 - 7411.5

363

129

7222.5

7257.5 7383.5 - 7418.5

364

131

7229.5

7264.5 7390.5 - 7425.5

365

132

7390.5

527-705/26

Mounting
type

Standard(*)
(A)

365
350

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-77

2 - PLANNING

Tab. 2.44

ODU (7.4 - 7.7 GHz) composition; Fs=161 MHz


7.4 - 7.7 GHz

FREQUENCY SHIFTER - 161 MHz (first digit Ext.= 1)


ODU
Rx FREQ. (MHz)
P/N

732-241/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

134

7585.5

7620.5 7424.5 - 7459.5

366

136

7592.5

7627.5 7431.5 - 7466.5

367

138

7599.5

7634.5 7438.5 - 7473.5

368

140

7606.5

7641.5 7445.5 - 7480.5

369

142

7613.5

7648.5 7452.5 - 7487.5

370

144

7620.5

7655.5 7459.5 - 7494.5

371

146

7627.5

7662.5 7466.5 - 7501.5

372

148

7634.5

7669.5 7473.5 - 7508.5

373

150

7641.5

7676.5 7480.5 - 7515.5

374

152

7648.5

7683.5 7487.5 - 7522.5

375

154

7655.5

7690.5 7494.5 - 7529.5

376

156

7662.5

7697.5 7501.5 - 7536.5

377

158

7669.5

7704.5 7508.5 - 7543.5

378

160

7676.5

7711.5 7515.5 - 7550.5

379

162

7683.5

7718.5 7522.5 - 7557.5

380

164

7690.5

7725.5 7529.5 - 7564.5

133

7424.5

7459.5 7585.5 - 7620.5

135

7431.5

7466.5 7592.5 - 7627.5

367

137

7438.5

7473.5 7599.5 - 7634.5

368

139

7445.5

7480.5 7606.5 - 7641.5

369

141

7452.5

7487.5 7613.5 - 7648.5

370

143

7459.5

7494.5 7620.5 - 7655.5

371

145

7466.5

7501.5 7627.5 - 7662.5

372

147

7473.5

7508.5 7634.5 - 7669.5

373

149

7480.5

7515.5 7641.5 - 7676.5

374

151

7487.5

7522.5 7648.5 - 7683.5

375

153

7494.5

7529.5 7655.5 - 7690.5

376

155

7501.5

7536.5 7662.5 - 7697.5

377

157

7508.5

7543.5 7669.5 - 7704.5

378

159

7515.5

7550.5 7676.5 - 7711.5

379

161

7522.5

7557.5 7683.5 - 7718.5

380

163

7529.5

7564.5 7690.5 - 7725.5

381

620-015/51

620-015/70
(732-241/07R1)

527-705/35

Mounting
type

Standard(*)
(A)

381
366

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-78

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.45

ODU (7.4 - 7.9 GHz) composition; Fs=245 MHz


7.4 - 7.9 GHz

FREQUENCY SHIFTER - 245 MHz (first digit Ext.= 2)


ODU
Rx FREQ. (MHz)
P/N

732-241/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Annex 4

Diplexer filter
P/N

Ext.

202

7673

7708

7428 - 7463

450

204

7680

7715

7435 - 7470

451

206

7687

7722

7442 - 7477

452

208

7694

7729

7449 - 7484

210

7701

7736

7456 - 7491

212

7708

7743

7463 - 7498

455

214

7715

7750

7470 - 7505

456

216

7722

7757

7477 - 7512

457

218

7729

7764

7484 - 7519

458

220

7736

7771

7491 - 7526

459

222

7743

7778

7498 - 7533

460

224

7750

7785

7505 - 7540

461

226

7757

7792

7512 - 7547

462

228

7764

7799

7519 - 7554

230

7771

7806

7526 - 7561

232

7778

7813

7533 - 7568

465

234

7785

7820

7540 - 7575

466

236

7792

7827

7547 - 7582

467

238

7799

7834

7554 - 7589

468

240

7806

7841

7561 - 7596

469

242

7813

7848

7568 - 7603

470

244

7820

7855

7575 - 7610

471

246

7827

7862

7582 - 7617

472

248

7834

7869

7589 - 7624

250

7841

7876

7596 - 7631

252

7848

7883

7603 - 7638

475

254

7855

7890

7610 - 7645

476

256

7862

7897

7617 - 7652

477

527-705/35

620-015/51

620-015/70
(732-241/07R1)

527-705/36

527-705/38

Mounting
type

453
454

463
464

Standard(*)
(A)

473
474

continue

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-79

2 - PLANNING

7.4 - 7.9 GHz


FREQUENCY SHIFTER - 245 MHz (first digit Ext.= 2)
ODU
Rx FREQ. (MHz)
P/N

732-241/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Annex 4

Diplexer filter
P/N

Ext.

201

7428

7463

7673 - 7708

450

203

7435

7470

7680 - 7715

451

205

7442

7477

7687 - 7722

452

207

7449

7484

7694 - 7729

209

7456

7491

7701 - 7736

211

7463

7498

7708 - 7743

455

213

7470

7505

7715 - 7750

456

215

7477

7512

7722 - 7757

457

217

7484

7519

7729 - 7764

458

219

7491

7526

7736 - 7771

459

221

7498

7533

7743 - 7778

460

223

7505

7540

7750 - 7785

461

225

7512

7547

7757 - 7792

462

227

7519

7554

7764 - 7799

229

7526

7561

7771 - 7806

231

7533

7568

7778 - 7813

465

233

7540

7575

7785 - 7820

466

235

7547

7582

7792 - 7827

467

237

7554

7589

7799 - 7834

468

239

7561

7596

7806 - 7841

469

241

7568

7603

7813 - 7848

470

243

7575

7610

7820 - 7855

471

245

7582

7617

7827 - 7862

472

247

7589

7624

7834 - 7869

527-705/38 473

249

7596

7631

7841 - 7876

474

251

7603

7638

7848 - 7883

475

253

7610

7645

7855 - 7890

476

255

7617

7652

7862 - 7897

477

527-705/35

620-015/51

Mounting
type

453
454

527-705/36 463
620-015/70
(732-241/07R1)
464

Standard(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-80

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.46

ODU (7.75 - 7.975 GHz) composition; Fs=148.5 MHz


7.75 - 7.975 GHz

FREQUENCY SHIFTER - 148.5 MHz (first digit Ext.= 3)


ODU
Rx FREQ. (MHz)
P/N

732-241/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Bulgara channelling

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

302

7898.5

7933.5

7750 - 7785

550

304

7905.5

7940.5

7757 - 7792

551

306

7912.5

7947.5

7764 - 7799

552

308

7919.5

7954.5

7771 - 7806

553

310

7926.5

7961.5

7778 - 7813

554

312

7933.5

7968.5

7785 - 7820

555

314

7940.5

7975

7792 - 7826.5

301

7750

7785

7898.5 - 7933.5

303

7757

7792

7905.5 - 7940.5

551

305

7764

7799

7912.5 - 7947.5

552

307

7771

7806

7919.5 - 7954.5

553

309

7778

7813

7926.5 - 7961.5

554

311

7785

7820

7933.5 - 7968.5

555

313

7792

7826.5 7940.5 - 7975.0

556

620-015/51

620-015/71
(732-241/07R2)

527-705/61

Mounting
type

Standard(*)
(A)

556
550

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-81

2 - PLANNING

Tab. 2.47

ODU (7.1 - 7.4 GHz) composition; Fs=196 MHz


7.1 - 7.4 GHz

FREQUENCY SHIFTER - 196 MHz (first digit Ext.= 4)


ODU
Rx FREQ. (MHz)
P/N

732-241/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Annex 3

Diplexer filter
P/N

Ext.

402

7303

7338

7107 - 7142

150

404

7310

7345

7114 - 7149

151

406

7317

7352

7121 - 7156

152

408

7324

7359

7128 - 7163

153

410

7331

7366

7135 - 7170

154

412

7338

7373

7142 - 7177

155

414

7345

7380

7149 - 7184

156

416

7352

7387

7156 - 7191

527-705/26 157

418

7359

7394

7163 - 7198

158

420

7366

7401

7170 - 7205

159

422

7373

7408

7177 - 7212

160

424

7380

7415

7184 - 7219

161

426

7387

7422

7191 - 7226

162

428

7394

7429

7198 - 7233

163

430

7401

7436

7205 - 7240

164

432

7408

7443

7212 - 7247

401

7107

7142

7303 - 7338

403

7114

7149

7310 - 7345

151

405

7121

7156

7317 - 7352

152

407

7128

7163

7324 - 7359

153

409

7135

7170

7331 - 7366

154

411

7142

7177

7338 - 7373

155

413

7149

7184

7345 - 7380

156

415

7156

7191

7352 - 7387

527-705/26 157

417

7163

7198

7359 - 7394

158

419

7170

7205

7366 - 7401

159

421

7177

7212

7373 - 7408

160

423

7184

7219

7380 - 7415

161

425

7191

7226

7387 - 7422

162

427

7198

7233

7394 - 7429

163

429

7205

7240

7401 - 7436

164

431

7212

7247

7408 - 7443

527-705/27 165

620-015/51

Mounting
type

Standard(*)
(A)

527-705/27 165
620-015/70
(732-241/07R1)
150

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-82

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.48

ODU (7.4 - 7.7 GHz) composition; Fs=168 MHz


7.4 - 7.7 GHz

FREQUENCY SHIFTER - 168 MHz (first digit Ext.= 5)


ODU
Rx FREQ. (MHz)
P/N

732-241/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Annex 3

Diplexer filter
P/N

Ext.

502

7611

7646

7443 - 7478

050

504

7618

7653

7450 - 7485

051

506

7625

7660

7457 - 7492

052

508

7632

7667

7464 - 7499

053

510

7639

7674

7471 - 7506

054

512

7646

7681

7478 - 7513

055

514

7653

7688

7485 - 7520

056

516

7660

7695

7492 - 7527

057

518

7667

7702

7499 - 7534

058

520

7674

7709

7506 - 7541

059

522

7681

7716

7513 - 7548

060

524

7688

7723

7520 - 7555

061

526

7695

7730

7527 - 7562

062

528

7702

7737

7534 - 7569

063

530

7709

7744

7541 - 7576

064

532

7716

7751

7548 - 7583

501

7443

7478

7611 - 7646

503

7450

7485

7618 - 7653

051

505

7457

7492

7625 - 7660

052

507

7464

7499

7632 - 7667

053

509

7471

7506

7639 - 7674

054

511

7478

7513

7646 - 7681

055

513

7485

7520

7653 - 7688

056

515

7492

7527

7660 - 7695

057

517

7499

7534

7667 - 7702

058

519

7506

7541

7674 - 7709

059

521

7513

7548

7681 - 7716

060

523

7520

7555

7688 - 7723

061

525

7527

7562

7695 - 7730

062

527

7534

7569

7702 - 7737

063

529

7541

7576

7709 - 7744

064

531

7548

7583

7716 - 7751

065

620-015/51

620-015/70
(732-241/07R1)

527-705/35

Mounting
type

Standard(*)
(A)

065
050

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-83

2 - PLANNING

2.3.15.2

8 GHz ODU HD/HP

Tab. 2.49

ODU (7.7 - 8.2 GHz) composition; Fs=311.25 MHz


7.7 - 8.2 GHz

FREQUENCY SHIFTER - 311.25 MHz (first digit Ext.= 2)


ODU
P/N

732-241/08

Reference: Rec. ITU-R 386-6

Tx FREQ. (MHz)
Ext.

Rx FREQ.
(MHz)

TF
MIN

TF
MAX

Modem

Associated
RF group
(non
extended
ODU)

Annex 1

Diplexer filter
P/N

Ext.

201

7732-7767

8043.25-8078.25

151

203

7739-7774

8050.25-8085.25

152

205

7746-7781

8057.25-8092.25

153

207

7753-7788

8064.25-8099.25

154

209

7760-7795

8071.25-8106.25

155

211

7767-7802

8078.25-8113.25

156

213

7774-7809

8085.25-8120.25

157

215

7781-7816

8092.25-8127.25

217

7788-7823

8099.25-8134.25

219

7795-7830

8106.25-8141.25

160

221

7802-7837

8113.25-8148.25

161

223

7809-7844

8120.25-8155.25

162

225

7816-7851

8127.25-8162.25

163

227

7823-7858

8134.25-8169.25

164

229

7830-7865

8141.25-8176.25

231

7837-7872

8148.25-8183.25

233

7844-7879

8155.25-8190.25

235

7851-7886

8162.25-8197.25

237

7858-7893

8169.25-8204.25

169

239

7865-7900

8176.25-8211.25

170

241

7872-7907

8183.25-8218.25

171

243

7879-7914

8190.25-8225.25

172

245

7886-7921

8197.25-8232.25

173

247

7893-7928

8204.25-8239.25

249

7900-7935

8211.25-8246.25

251

7907-7942

8218.25-8253.25

176

253

7914-7949

8225.25-8260.25

177

255

7921-7956

8232.25-8267.25

178

257

7928-7963

8239.25-8274.25

179

259

7935-7970.5

8246.25-8281.75

180

527-705/62

620-015/51

158
159

165

620-015/71

166
527-705/66

527-705/67

Mounting
type

Reverse(*)
(B)

167
168

174
175

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-84

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.50

ODU (7.7 - 8.2 GHz) composition; Fs=311.25 MHz


7.7 - 8.2 GHz

FREQUENCY SHIFTER - 311.25 MHz (first digit Ext.= 2)


Tx FREQ.
(MHz)

ODU
P/N

732-241/08

Ext.

Rx FREQ.
(MHz)

Reference: Rec. ITU-R 386-6

TF
MIN

TF
MAX

Modem

Associated
RF group
(non
extended
ODU)

Annex 1

Diplexer filter
P/N

Ext.

202

8043.25-8078.25

7732-7767

151

204

8050.25-8085.25

7739-7774

152

206

8057.25-8092.25

7746-7781

153

208

8064.25-8099.25

7753-7788

154

210

8071.25-8106.25

7760-7795

155

212

8078.25-8113.25

7767-7802

156

214

8085.25-8120.25

7774-7809

157

216

8092.25-8127.25

7781-7816

218

8099.25-8134.25

7788-7823

220

8106.25-8141.25

7795-7830

160

222

8113.25-8148.25

7802-7837

161

224

8120.25-8155.25

7809-7844

162

226

8127.25-8162.25

7816-7851

163

228

8134.25-8169.25

7823-7858

164

230

8141.25-8176.25

7830-7865

232

8148.25-8183.25

7837-7872

234

8155.25-8190.25

7844-7879

236

8162.25-8197.25

7851-7886

238

8169.25-8204.25

7858-7893

169

240

8176.25-8211.25

7865-7900

170

242

8183.25-8218.25

7872-7907

171

244

8190.25-8225.25

7879-7914

172

246

8197.25-8232.25

7886-7921

173

248

8204.25-8239.25

7893-7928

250

8211.25-8246.25

7900-7935

252

8218.25-8253.25

7907-7942

176

254

8225.25-8260.25

7914-7949

177

256

8232.25-8267.25

7921-7956

178

258

8239.25-8274.25

7928-7963

179

260

8246.25-8281.75

7935-7970.5

180

527-705/62

620-015/51

158
159

165

620-015/71

166
527-705/66

527-705/67

Mounting
type

Standard(*)
(A)

167
168

174
175

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-85

2 - PLANNING

Tab. 2.51

ODU (8.275-8.5 GHz) composition; Fs=126 MHz


8.275-8.5 GHz

FREQUENCY SHIFTER - 126 MHz (first digit Ext.= 0)


ODU
P/N

732-241/08

Ext.

Rx FREQ.
(MHz)

Reference: Rec. ITU-R 386-6

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Associated
RF group
(non
extended
ODU)

Annex 3
Diplexer filter

P/N

Ext.

001

8279-8314

8405-8440

650

003

8286-8321

8412-8447

651

005

8293-8328

8419-8454

652

007

8300-8335

8426-8461

009

8307-8342

8433-8468

654

011

8314-8349

8440-8475

655

013

8321-8356

8447-8482

656

015

8328-8363

8454-8489

017

8335-8370

8461-8496

002

8405-8440

8279-8314

004

8412-8447

8286-8321

006

8419-8454

8293-8328

008

8426-8461

8300-8335

010

8433-8468

8307-8342

654

012

8440-8475

8314-8349

655
656

014

8447-8482

8321-8356

016

8454-8489

8328-8363

018

8461-8496

8335-8370

527-705/73

527-705/74
620-015/51

620-015/71

653

Mounting
type

Reverse(*)
(B)

657
658
650
651
652

527-705/73

527-705/74

653

Standard(*)
(A)

657
658

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-86

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.52

ODU (8.275-8.5 GHz) composition; Fs=119 MHz


8.275-8.5 GHz

FREQUENCY SHIFTER - 119 MHz (first digit Ext.= 1)


Tx FREQ.
(MHz)

ODU
P/N

732-241/08

Ext.

Rx FREQ.
(MHz)

Reference: Rec. ITU-R 386-6

TF
MIN

TF
MAX

Modem

Associated
RF group
(non
extended
ODU)

Annex 3
Diplexer filter

P/N

Ext.

101

8279-8314

8398-8433

050

103

8286-8321

8405-8440

051

105

8293-8328

8412-8447

052

107

8300-8335

8419-8454

109

8307-8342

8426-8461

054

111

8314-8349

8433-8468

055

113

8321-8356

8440-8475

056

115

8328-8363

8447-8482

117

8335-8370

8454-8489

119

8342-8337

8461-8496

102

8398-8433

8279-8314

104

8405-8440

8286-8321

106

8412-8447

8293-8328

108

8419-8454

8300-8335

110

8426-8461

8307-8342

054

112

8433-8468

8314-8349

055

114

8440-8475

8321-8356

056

116

8447-8482

8328-8363

118

8454-8489

8335-8370

120

8461-8496

8342-8337

527-705/73

Mounting
type

053
Reverse(*)
(B)

057
527-705/74
620-015/51

058
059

620-015/71

050
051
527-705/73

052
053
Standard(*)
(A)

057
527-705/74

058
059

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-87

2 - PLANNING

2.3.15.3

15 GHz ODU HD/HP

Tab. 2.53

ODU (14.40 - 15.35 GHz) composition; Fs=336 MHz


14.40 - 15.35 GHz

FREQUENCY SHIFTER - 336 MHz (first digit EXT.= 0)


ODU
P/N

732-241/15

Rx FREQ.
Ext.

(MHz)

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R F.636

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

002

14931

15015

14595 - 14679

011

004

14978

15062

14642 - 14726

012

006

15025

15109

14689 - 14773

008

15072

15156

14736 - 14820

010

15119

15203

14783 - 14867

012

15162

15246

14826 - 14910

001

14595

14679

14931 - 15015

003

14642

14726

14978 - 15062

012

005

14689

14773

15025 - 15109

013

007

14736

14820

15072 - 15156

009

14783

14867

15119 - 15203

015

011

14826

14910

15162 - 15246

016

013

620-015/80
(732-241/15L)

014

Mounting
type

Standard(*)
(A)

015
620-015/51

527-904/76

620-015/81
(732-241/15H)

016
011

014

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-88

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.54

ODU (14.40 - 15.35 GHz) composition; Fs=420 MHz


14.40 - 15.35 GHz

FREQUENCY SHIFTER - 420 MHz (first digit EXT.= 1)


ODU
P/N

732-241/15

Rx FREQ.
(MHz)

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

102

14920

15035

14500 - 14615

104

14999

15114

14579 - 14694

106

15078

15193

14658 - 14773

108

15157

15272

14737 - 14852

110

15235

15350

14815 - 14930

101

14500

14615

14920 - 15035

103

14579

14694

14999 - 15114

105

14658

14773

15078 - 15193

107

14737

14852

15157 - 15272

109

14815

14930

15235 - 15350

Reference: Rec. ITU-R F.636

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

Mounting
type

111
112

620-015/80
(732-241/15L)
620-015/51

113

Standard(*)
(A)

114
527-904/75

115
111
112

620-015/81
(732-241/15H)

113
114

Reverse(*)
(B)

115

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

Tab. 2.55

ODU (14.40 - 15.35 GHz) composition; Fs=728 MHz


14.40 - 15.35 GHz

FREQUENCY SHIFTER - 728 MHz (first digit EXT.= 4)


ODU
P/N

732-241/15

Rx FREQ.
Ext.

(MHz)

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

402

15229

15348

14501 - 14620

401

14501

14620

15229 - 15348

Reference: Rec. ITU-R F.636

Modem

620-015/51

Associated
RF group
(non extended
ODU)
620-015/80
(732-241/15L)
620-015/81
(732-241/15H)

Diplexer filter
P/N

527-904/75

Ext.

Mounting
type

401

Standard(*)
(A)

401

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-89

2 - PLANNING

Tab. 2.56

ODU (14.40 - 15.35 GHz) composition; Fs=490 MHz


14.40 - 15.35 GHz

FREQUENCY SHIFTER - 490 MHz (first digit EXT.= 5)


ODU
P/N

732-241/15

Rx FREQ.
(MHz)

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

502

14893 - 15012

14403 - 14522

504

14977 - 15096

14487 - 14606

506

15061 - 15180

14751 - 14690

508

15145 - 15264

14655 - 14774

510

15229 - 15348

14739 - 14858

501

14403 - 14522

14893 - 15012

503

14487 - 14606

14977 - 15096

505

14751 - 14690

15061 - 15180

507

14655 - 14774

15145 - 15264

509

14739 - 14858

15229 - 15348

Reference: Rec. ITU-R F.636

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

Mounting
type

511
512

620-015/80
(732-241/15L)
620-015/51

513

Standard(*)
(A)

514
527-904/75

515
511
512

620-015/81
(732-241/15H)

513
514

Reverse(*)
(B)

515

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).
Tab. 2.57

ODU (14.40 - 15.35 GHz) composition; Fs=315 MHz


14.40 - 15.35 GHz

FREQUENCY SHIFTER - 315 MHz (first digit EXT.= 6)


ODU
P/N

732-241/15

Rx FREQ.
Ext.

(MHz)

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

602

14941 - 15021

14626 - 14706

604

14993 - 15073

14678 - 14758

606

15045 - 15125

14730 - 14810

608

15097 - 15177

14782 - 14862

610

15149 - 15229

14834 - 14914

601

14626 - 14706

14941 - 15021

603

14678 - 14758

14993 - 15073

605

14730 - 14810

15045 - 15125

607

14782 - 14862

15097 - 15177

609

14834 - 14914

15149 - 15229

Reference: Rec. ITU-R F.636

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

Mounting
type

601
602
620-015/80
(732-241/15L)
620-015/51

603
604
527-904/76

620-015/81
(732-241/15H)

Standard(*)
(A)

605
601
602
603
604

Reverse(*)
(B)

605

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-90

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.58

ODU (14.40 - 15.35 GHz) composition; Fs=322 MHz


14.40 - 15.35 GHz

FREQUENCY SHIFTER - 322 MHz (first digit EXT.= 7)


ODU
P/N

732-241/15

Rx FREQ.
Ext.

(MHz)

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

702

14949 - 15029

14627 - 14707

704

15001 - 15081

14679 - 14759

706

15053 - 15133

14731 - 14811

708

15105 - 15185

14783 - 14863

710

15157 - 15237

14835 - 14915

701

14627 - 14707

14949 - 15029

703

14679 - 14759

15001 - 15081

705

14731 - 14811

15053 - 15133

707

14783 - 14863

15105 - 15185

709

14835 - 14915

15157 - 15237

Reference: Rec. ITU-R F.636

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

Mounting
type

701
702

620-015/80
(732-241/15L)
620-015/51

703
704
527-904/76

620-015/81
(732-241/15H)

Standard(*)
(A)

705
701
702
703
704

Reverse(*)
(B)

705

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-91

2 - PLANNING

2.3.15.4

18 GHz ODU HD/HP

Tab. 2.59

ODU (17.7 - 19.7 GHz) composition; Fs=340 MHz


17.7 - 19.7 GHz

FREQUENCY SHIFTER - 340 MHz (first digit EXT.= 0)


ODU
P/N

Rx FREQ.
(MHz)

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R F.595


Associated
RF group
(non extended
ODU)

Modem

Diplexer filter
P/N

Ext.

002

18915

19057

18575 - 18717

620-015/68
(732-241/18L)

527-904/89

004

19023

19165

18683 - 18825

620-015/68
(732-241/18L)

527-904/90

732-241/18

620-015/51
001

18575

18717

18915 - 19057

620-015/69
(732-241/18H)

527-904/89

003

18683

18825

19023 - 19165

620-015/69
(732-241/18H)

527-904/90

Mounting
type

Standard(*)
(A)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

Tab. 2.60

ODU (17.7 - 19.7 GHz) composition; Fs=1010 MHz


17.7 - 19.7 GHz

FREQUENCY SHIFTER - 1010 MHz (first digit EXT.= 1)


ODU
P/N

Rx FREQ.
Ext.

(MHz)

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R F.595

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

102

18710

19219

17700 - 18209

620-015/68
(732-241/18L)

527-904/72

104

19191

19700

18181 - 18690

620-015/68
(732-241/18L)

527-904/73

732-241/18

620-015/51
101

17700

18209

18710 - 19219

620-015/69
(732-241/18H)

527-904/72

103

18181

18690

19191 - 19700

620-015/69
(732-241/18H)

527-904/73

Mounting
type

Standard(*)
(A)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-92

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.3.15.5

23 GHz ODU HD/HP

Tab. 2.61

ODU (21.2 - 23.6 GHz) composition; Fs=1008 MHz


21.2 - 23.6 GHz

FREQUENCY SHIFTER - 1008 MHz (first digit EXT.= 0)


ODU
P/N

Tx FREQ.
(MHz)

Rx FREQ.
(MHz)

Ext.

Reference: Rec. ITU-R F.637

TF
MIN

TF
MAX

002

23010.5

23599 22002.5 - 22591

001

22002.5

22591 23010.5 - 23599

732-241/23

Modem

620-015/51

Associated
RF group
(non
extended
ODU)

Annex 1

Diplexer filter
Mounting
type

P/N

Ext.

527-904/77

Standard(*)
(A)

620-015/83
527-904/77
(732-241/23H)

Reverse(*)
(B)

620-015/82
(732-241/23L)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2.3.15.6

26 GHz ODU HD/HP

Tab. 2.62

ODU (24.5 - 26.5 GHz) composition; Fs=1008 MHz


24.5 - 26.5 GHz

FREQUENCY SHIFTER - 1008 MHz (first digit EXT.= 0)


ODU
P/N

Tx FREQ.
(MHz)

Rx FREQ.
Ext.

(MHz)

Reference: Rec. ITU-R F.748

TF
MIN

TF
MAX

Modem

Associated
RF group
(non
extended
ODU)

Diplexer filter
P/N

Ext.

002

25557

26019

24549 - 25011

620-015/51
(732-241/26L)

527-904/18

004

25991

26453

24983 - 25445

620-015/51
(732-241/26L)

527-904/19

732-241/26

620-015/51
001

24549

25011

25557 - 26019

620-015/51
527-904/18
(732-241/26H)

003

24983

25445

25991 - 26453

620-015/51
527-904/19
(732-241/26H)

Mounting
type

Standard(*)
(A)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-93

2 - PLANNING

2.3.15.7

28 GHz ODU HD/HP

Tab. 2.63

ODU (28.5 - 29.5 GHz) composition; Fs=1008 MHz


28.5 - 29.5 GHz

FREQUENCY SHIFTER - 1008 MHz (first digit EXT.= 0)


ODU
P/N

Tx FREQ.
(MHz)

Rx FREQ.
(MHz)

Ext.

Reference: Rec. ITU-R F.748

TF
MAX

TF MIN

Modem

Associated
RF group
(non
extended
ODU)

Annex 2

Diplexer filter
P/N

Ext.

002

28556.5

29018.5 27548.5 - 28010.5

620-015/88
527-904/70
(732-241/28L)

004

28990.5

29452.5 27982.5 - 28444.5

620-015/88
527-904/71
(732-241/28L)

001

27548.5

28010.5 28556.5 - 29018.5

620-015/88
527-904/70
(732-241/28H)

003

27982.5

28444.5 28990.5 - 29452.5

620-015/88
527-904/71
(732-241/28H)

732-241/28

620-015/51

Mounting
type

Standard(*)
(A)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2.3.15.8

38 GHz ODU HD/HP

Tab. 2.64

ODU (37 - 39.5 GHz) composition; Fs=1260 MHz


37 - 39.5 GHz

FREQUENCY SHIFTER - 1260 MHz (first digit Ext.= 0) Reference: Rec. ITU-R 749-2 Annex 1
ODU
P/N

Ext.

Rx FREQ.
(MHz)

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

002

38304 - 38875

37044 - 37625

620-015/47
527-904/48
( 732-241/38L1 )

004

38857 - 39438

37597 - 38178

620-015/48
527-904/49
( 732-241/38L2 )

732-241/38

620-015/51
001

37044 - 37625

38304 - 38875

620-015/49
527-904/48
( 732-241/38H1 )

003

37597 - 38178

38857 - 39438

620-015/50
527-904/49
( 732-241/38H2 )

Mounting
type

Standard(*)
(A)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-94

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.43

7, 8, 15, 18, 23, 26, 28 and 38 GHz ODU HD/HP: Diplexer position according to the
mounting type (A or B)

MOUNTING A DIPLEXER POSITION

MOUNTING B DIPLEXER POSITION

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-95

2 - PLANNING

2.3.15.9

7 GHz ODU ND

Tab. 2.65

ODU (7.4 - 7.7 GHz) composition; Fs=154 MHz


7.4 - 7.7 GHz

FREQUENCY SHIFTER - 154 MHz (first digit Ext.= 0)


ODU
P/N

732-251/07

Ext.

Rx FREQ.
(MHz)

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Annex 1

Diplexer filter
P/N

Ext.

002

7582

- 7617

7428 - 7463

250

004

7589

- 7624

7435 - 7470

251

006

7596

- 7631

7442 - 7477

252

008

7603

- 7638

7449 - 7484

253

010

7610

- 7645

7456 - 7491

254

012

7617

- 7652

7463 - 7498

255

014

7624

- 7659

7470 - 7505

256

016

7631

- 7666

7477 - 7512

257

018

7638

- 7673

7484 - 7519

258

020

7645

- 7680

7491 - 7526

259

022

7652

- 7687

7498 - 7533

260

024

7659

- 7694

7505 - 7540

261

026

7666

- 7701

7512 - 7547

262

028

7673

- 7708

7519 - 7554

263

030

7680

- 7715

7526 - 7561

264

032

7687

- 7722

7533 - 7568

523-410/29

602-011/94
(732-251/07R1)

527-705/35

Mounting
type

Standard(*)
(A)

265

001

7428

- 7463

7582 - 7617

003

7435

- 7470

7589 - 7624

251

250

005

7442

- 7477

7596 - 7631

252

007

7449

- 7484

7603 - 7638

253

009

7456

- 7491

7610 - 7645

254

011

7463

- 7498

7617 - 7652

255

013

7470

- 7505

7624 - 7659

256

015

7477

- 7512

7631 - 7666

257

017

7484

- 7519

7638 - 7673

258

019

7491

- 7526

7645 - 7680

259

021

7498

- 7533

7652 - 7687

260

023

7505

- 7540

7659 - 7694

261

025

7512

- 7547

7666 - 7701

262

027

7519

- 7554

7673 - 7708

263

029

7526

- 7561

7680 - 7715

264

031

7533

- 7568

7687 - 7722

265

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-96

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.66

ODU (7.1 - 7.4 GHz) composition; Fs=161 MHz


7.1 - 7.4 GHz

FREQUENCY SHIFTER - 161 MHz (first digit Ext.= 1)


ODU
Rx FREQ. (MHz)
P/N

732-251/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Reference: Rec. ITU-R 385-7


Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

102

7285.5

7320.5 7124.5 - 7159.5

350

104

7292.5

7327.5 7131.5 - 7166.5

351

106

7299.5

7334.5 7138.5 - 7173.5

352

108

7306.5

7341.5 7145.5 - 7180.5

353

110

7313.5

7348.5 7152.5 - 7187.5

354

112

7320.5

7355.5 7159.5 - 7194.5

355

114

7327.5

7362.5 7166.5 - 7201.5

356

116

7334.5

7369.5 7173.5 - 7208.5

357

118

7341.5

7376.5 7180.5 - 7215.5

358

120

7348.5

7383.5 7187.5 - 7222.5

359

122

7355.5

7390.5 7194.5 - 7229.5

360

124

7362.5

7397.5 7201.5 - 7236.5

361

126

7369.5

7404.5 7208.5 - 7243.5

362

128

7376.5

7411.5 7215.5 - 7250.5

363

130

7383.5

7418.5 7222.5 - 7257.5

364

101

7124.5

602-011/94
7425.5 7229.5 - 7264.5
523-410/29
(732-251/07R1)
7159.5 7285.5 - 7320.5

103

7131.5

7166.5 7292.5 - 7327.5

351

105

7138.5

7173.5 7299.5 - 7334.5

352

107

7145.5

7180.5 7306.5 - 7341.5

353

109

7152.5

7187.5 7313.5 - 7348.5

354

111

7159.5

7194.5 7320.5 - 7355.5

355

113

7166.5

7201.5 7327.5 - 7362.5

356

115

7173.5

7208.5 7334.5 - 7369.5

357

117

7180.5

7215.5 7341.5 - 7376.5

358

119

7187.5

7222.5 7348.5 - 7383.5

359

121

7194.5

7229.5 7355.5 - 7390.5

360

123

7201.5

7236.5 7362.5 - 7397.5

361

125

7208.5

7243.5 7369.5 - 7404.5

362

127

7215.5

7250.5 7376.5 - 7411.5

363

129

7222.5

7257.5 7383.5 - 7418.5

364

131

7229.5

7264.5 7390.5 - 7425.5

365

132

7390.5

527-705/26

Mounting
type

Standard(*)
(A)

365
350

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-97

2 - PLANNING

Tab. 2.67

ODU (7.4 - 7.7 GHz) composition; Fs=161 MHz


7.4 - 7.7 GHz

FREQUENCY SHIFTER - 161 MHz (first digit Ext.= 1)


ODU
Rx FREQ. (MHz)
P/N

732-251/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

134

7585.5

7620.5 7424.5 - 7459.5

366

136

7592.5

7627.5 7431.5 - 7466.5

367

138

7599.5

7634.5 7438.5 - 7473.5

368

140

7606.5

7641.5 7445.5 - 7480.5

369

142

7613.5

7648.5 7452.5 - 7487.5

370

144

7620.5

7655.5 7459.5 - 7494.5

371

146

7627.5

7662.5 7466.5 - 7501.5

372

148

7634.5

7669.5 7473.5 - 7508.5

373

150

7641.5

7676.5 7480.5 - 7515.5

374

152

7648.5

7683.5 7487.5 - 7522.5

375

154

7655.5

7690.5 7494.5 - 7529.5

376

156

7662.5

7697.5 7501.5 - 7536.5

377

158

7669.5

7704.5 7508.5 - 7543.5

378

160

7676.5

7711.5 7515.5 - 7550.5

379

162

7683.5

7718.5 7522.5 - 7557.5

380

164

7690.5

7725.5 7529.5 - 7564.5

133

7424.5

7459.5 7585.5 - 7620.5

135

7431.5

7466.5 7592.5 - 7627.5

367

137

7438.5

7473.5 7599.5 - 7634.5

368

139

7445.5

7480.5 7606.5 - 7641.5

369

141

7452.5

7487.5 7613.5 - 7648.5

370

143

7459.5

7494.5 7620.5 - 7655.5

371

145

7466.5

7501.5 7627.5 - 7662.5

372

147

7473.5

7508.5 7634.5 - 7669.5

373

149

7480.5

7515.5 7641.5 - 7676.5

374

151

7487.5

7522.5 7648.5 - 7683.5

375

153

7494.5

7529.5 7655.5 - 7690.5

376

155

7501.5

7536.5 7662.5 - 7697.5

377

157

7508.5

7543.5 7669.5 - 7704.5

378

159

7515.5

7550.5 7676.5 - 7711.5

379

161

7522.5

7557.5 7683.5 - 7718.5

380

163

7529.5

7564.5 7690.5 - 7725.5

381

523-410/29

602-011/94
(732-251/07R1)

527-705/35

Mounting
type

Standard(*)
(A)

381
366

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-98

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.68

ODU (7.4 - 7.9 GHz) composition; Fs=245 MHz


7.4 - 7.9 GHz

FREQUENCY SHIFTER - 245 MHz (first digit Ext.= 2)


ODU
Rx FREQ. (MHz)
P/N

732-251/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Annex 4

Diplexer filter
P/N

Ext.

202

7673

7708

7428 - 7463

450

204

7680

7715

7435 - 7470

451

206

7687

7722

7442 - 7477

452

208

7694

7729

7449 - 7484

210

7701

7736

7456 - 7491

212

7708

7743

7463 - 7498

455

214

7715

7750

7470 - 7505

456

216

7722

7757

7477 - 7512

457

218

7729

7764

7484 - 7519

458

220

7736

7771

7491 - 7526

459

222

7743

7778

7498 - 7533

460

224

7750

7785

7505 - 7540

461

226

7757

7792

7512 - 7547

462

228

7764

7799

7519 - 7554

230

7771

7806

7526 - 7561

232

7778

7813

7533 - 7568

465

234

7785

7820

7540 - 7575

466

236

7792

7827

7547 - 7582

467

238

7799

7834

7554 - 7589

468

240

7806

7841

7561 - 7596

469

242

7813

7848

7568 - 7603

470

244

7820

7855

7575 - 7610

471

246

7827

7862

7582 - 7617

472

248

7834

7869

7589 - 7624

250

7841

7876

7596 - 7631

252

7848

7883

7603 - 7638

475

254

7855

7890

7610 - 7645

476

256

7862

7897

7617 - 7652

477

527-705/35

523-410/29

602-011/94
(732-251/07R1)

527-705/36

527-705/38

Mounting
type

453
454

463
464

Standard(*)
(A)

473
474

continue

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-99

2 - PLANNING

7.4 - 7.9 GHz


FREQUENCY SHIFTER - 245 MHz (first digit Ext.= 2)
ODU
Rx FREQ. (MHz)
P/N

732-251/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Annex 4

Diplexer filter
P/N

Ext.

201

7428

7463

7673 - 7708

450

203

7435

7470

7680 - 7715

451

205

7442

7477

7687 - 7722

452

207

7449

7484

7694 - 7729

209

7456

7491

7701 - 7736

211

7463

7498

7708 - 7743

455

213

7470

7505

7715 - 7750

456

215

7477

7512

7722 - 7757

457

217

7484

7519

7729 - 7764

458

219

7491

7526

7736 - 7771

459

221

7498

7533

7743 - 7778

460

223

7505

7540

7750 - 7785

461

225

7512

7547

7757 - 7792

462

227

7519

7554

7764 - 7799

229

7526

7561

7771 - 7806

231

7533

7568

7778 - 7813

465

233

7540

7575

7785 - 7820

466

235

7547

7582

7792 - 7827

467

237

7554

7589

7799 - 7834

468

239

7561

7596

7806 - 7841

469

241

7568

7603

7813 - 7848

470

243

7575

7610

7820 - 7855

471

245

7582

7617

7827 - 7862

472

247

7589

7624

7834 - 7869

527-705/38 473

249

7596

7631

7841 - 7876

474

251

7603

7638

7848 - 7883

475

253

7610

7645

7855 - 7890

476

255

7617

7652

7862 - 7897

477

527-705/35

523-410/29

Mounting
type

453
454

527-705/36 463
602-011/94
(732-251/07R1)
464

Standard(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-100

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.69

ODU (7.75 - 7.975 GHz) composition; Fs=148.5 MHz


7.75 - 7.975 GHz

FREQUENCY SHIFTER - 148.5 MHz (first digit Ext.= 3)


ODU
Rx FREQ. (MHz)
P/N

732-251/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Bulgara channelling

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

302

7898.5

7933.5

7750 - 7785

550

304

7905.5

7940.5

7757 - 7792

551

306

7912.5

7947.5

7764 - 7799

552

308

7919.5

7954.5

7771 - 7806

553

310

7926.5

7961.5

7778 - 7813

554

312

7933.5

7968.5

7785 - 7820

555

314

7940.5

7975

7792 - 7826.5

301

7750

7785

7898.5 - 7933.5

303

7757

7792

7905.5 - 7940.5

551

305

7764

7799

7912.5 - 7947.5

552

307

7771

7806

7919.5 - 7954.5

553

309

7778

7813

7926.5 - 7961.5

554

311

7785

7820

7933.5 - 7968.5

555

313

7792

7826.5 7940.5 - 7975.0

556

523-410/29

602-011/95
(732-251/07R2)

527-705/61

Mounting
type

Standard(*)
(A)

556
550

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-101

2 - PLANNING

Tab. 2.70

ODU (7.1 - 7.4 GHz) composition; Fs=196 MHz


7.1 - 7.4 GHz

FREQUENCY SHIFTER - 196 MHz (first digit Ext.= 4)


ODU
Rx FREQ. (MHz)
P/N

732-251/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Annex 3

Diplexer filter
P/N

Ext.

402

7303

7338

7107 - 7142

150

404

7310

7345

7114 - 7149

151

406

7317

7352

7121 - 7156

152

408

7324

7359

7128 - 7163

153

410

7331

7366

7135 - 7170

154

412

7338

7373

7142 - 7177

155

414

7345

7380

7149 - 7184

156

416

7352

7387

7156 - 7191

527-705/26 157

418

7359

7394

7163 - 7198

158

420

7366

7401

7170 - 7205

159

422

7373

7408

7177 - 7212

160

424

7380

7415

7184 - 7219

161

426

7387

7422

7191 - 7226

162

428

7394

7429

7198 - 7233

163

430

7401

7436

7205 - 7240

164

432

7408

7443

7212 - 7247

401

7107

7142

7303 - 7338

403

7114

7149

7310 - 7345

151

405

7121

7156

7317 - 7352

152

407

7128

7163

7324 - 7359

153

409

7135

7170

7331 - 7366

154

411

7142

7177

7338 - 7373

155

413

7149

7184

7345 - 7380

156

415

7156

7191

7352 - 7387

527-705/26 157

417

7163

7198

7359 - 7394

158

419

7170

7205

7366 - 7401

159

421

7177

7212

7373 - 7408

160

423

7184

7219

7380 - 7415

161

425

7191

7226

7387 - 7422

162

427

7198

7233

7394 - 7429

163

429

7205

7240

7401 - 7436

164

431

7212

7247

7408 - 7443

527-705/27 165

523-401/29

Mounting
type

Standard(*)
(A)

527-705/27 165
602-011/94
(732-251/07R1)
150

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-102

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.71

ODU (7.4 - 7.7 GHz) composition; Fs=168 MHz


7.4 - 7.7 GHz

FREQUENCY SHIFTER - 168 MHz (first digit Ext.= 5)


ODU
Rx FREQ. (MHz)
P/N

732-251/07

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Reference: Rec. ITU-R 385-7

Modem

Associated
RF group
(non extended
ODU)

Annex 3

Diplexer filter
P/N

Ext.

502

7611

7646

7443 - 7478

050

504

7618

7653

7450 - 7485

051

506

7625

7660

7457 - 7492

052

508

7632

7667

7464 - 7499

053

510

7639

7674

7471 - 7506

054

512

7646

7681

7478 - 7513

055

514

7653

7688

7485 - 7520

056

516

7660

7695

7492 - 7527

057

518

7667

7702

7499 - 7534

058

520

7674

7709

7506 - 7541

059

522

7681

7716

7513 - 7548

060

524

7688

7723

7520 - 7555

061

526

7695

7730

7527 - 7562

062

528

7702

7737

7534 - 7569

063

530

7709

7744

7541 - 7576

064

532

7716

7751

7548 - 7583

501

7443

7478

7611 - 7646

503

7450

7485

7618 - 7653

051

505

7457

7492

7625 - 7660

052

507

7464

7499

7632 - 7667

053

509

7471

7506

7639 - 7674

054

511

7478

7513

7646 - 7681

055

513

7485

7520

7653 - 7688

056

515

7492

7527

7660 - 7695

057

517

7499

7534

7667 - 7702

058

519

7506

7541

7674 - 7709

059

521

7513

7548

7681 - 7716

060

523

7520

7555

7688 - 7723

061

525

7527

7562

7695 - 7730

062

527

7534

7569

7702 - 7737

063

529

7541

7576

7709 - 7744

064

531

7548

7583

7716 - 7751

065

523-410/29

602-011/94
(732-251/07R1)

527-705/35

Mounting
type

Standard(*)
(A)

065
050

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-103

2 - PLANNING

2.3.15.10 8 GHz ODU ND


Tab. 2.72

ODU (7.7 - 8.2 GHz) composition; Fs=311.25 MHz


7.7 - 8.2 GHz

FREQUENCY SHIFTER - 311.25 MHz (first digit Ext.= 2)


ODU
P/N

732-251/08

Reference: Rec. ITU-R 386-6

Tx FREQ. (MHz)
Ext.

Rx FREQ.
(MHz)

TF
MIN

TF
MAX

Modem

Associated
RF group
(non
extended
ODU)

Annex 1

Diplexer filter
P/N

Ext.

201

7732-7767

8043.25-8078.25

151

203

7739-7774

8050.25-8085.25

152

205

7746-7781

8057.25-8092.25

153

207

7753-7788

8064.25-8099.25

154

209

7760-7795

8071.25-8106.25

155

211

7767-7802

8078.25-8113.25

156

213

7774-7809

8085.25-8120.25

157

215

7781-7816

8092.25-8127.25

217

7788-7823

8099.25-8134.25

219

7795-7830

8106.25-8141.25

160

221

7802-7837

8113.25-8148.25

161

223

7809-7844

8120.25-8155.25

162

225

7816-7851

8127.25-8162.25

163

227

7823-7858

8134.25-8169.25

164

229

7830-7865

8141.25-8176.25

231

7837-7872

8148.25-8183.25

233

7844-7879

8155.25-8190.25

235

7851-7886

8162.25-8197.25

237

7858-7893

8169.25-8204.25

169

239

7865-7900

8176.25-8211.25

170

241

7872-7907

8183.25-8218.25

171

243

7879-7914

8190.25-8225.25

172

245

7886-7921

8197.25-8232.25

173

247

7893-7928

8204.25-8239.25

249

7900-7935

8211.25-8246.25

251

7907-7942

8218.25-8253.25

176

253

7914-7949

8225.25-8260.25

177

255

7921-7956

8232.25-8267.25

178

257

7928-7963

8239.25-8274.25

179

259

7935-7970.5

8246.25-8281.75

180

527-705/62

523-410/29

158
159

165

602-011/95
(732-251/08)

166
527-705/66

527-705/67

Mounting
type

Reverse(*)
(B)

167
168

174
175

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-104

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.73

ODU (7.7 - 8.2 GHz) composition; Fs=311.25 MHz


7.7 - 8.2 GHz

FREQUENCY SHIFTER - 311.25 MHz (first digit Ext.= 2)


Tx FREQ.
(MHz)

ODU
P/N

732-251/08

Ext.

Rx FREQ.
(MHz)

Reference: Rec. ITU-R 386-6

TF
MIN

TF
MAX

Modem

Associated
RF group
(non
extended
ODU)

Annex 1

Diplexer filter
P/N

Ext.

202

8043.25-8078.25

7732-7767

151

204

8050.25-8085.25

7739-7774

152

206

8057.25-8092.25

7746-7781

153

208

8064.25-8099.25

7753-7788

154

210

8071.25-8106.25

7760-7795

155

212

8078.25-8113.25

7767-7802

156

214

8085.25-8120.25

7774-7809

157

216

8092.25-8127.25

7781-7816

218

8099.25-8134.25

7788-7823

220

8106.25-8141.25

7795-7830

160

222

8113.25-8148.25

7802-7837

161

224

8120.25-8155.25

7809-7844

162

226

8127.25-8162.25

7816-7851

163

228

8134.25-8169.25

7823-7858

164

230

8141.25-8176.25

7830-7865

232

8148.25-8183.25

7837-7872

234

8155.25-8190.25

7844-7879

236

8162.25-8197.25

7851-7886

238

8169.25-8204.25

7858-7893

169

240

8176.25-8211.25

7865-7900

170

242

8183.25-8218.25

7872-7907

171

244

8190.25-8225.25

7879-7914

172

246

8197.25-8232.25

7886-7921

173

248

8204.25-8239.25

7893-7928

250

8211.25-8246.25

7900-7935

252

8218.25-8253.25

7907-7942

176

254

8225.25-8260.25

7914-7949

177

256

8232.25-8267.25

7921-7956

178

258

8239.25-8274.25

7928-7963

179

260

8246.25-8281.75

7935-7970.5

180

527-705/62

523-410/29

158
159

165

602-011/95
(732-251/08)

166
527-705/66

527-705/67

Mounting
type

Standard(*)
(A)

167
168

174
175

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-105

2 - PLANNING

Tab. 2.74

ODU (8.275-8.5 GHz) composition; Fs=126 MHz


8.275-8.5 GHz

FREQUENCY SHIFTER - 126 MHz (first digit Ext.= 0)


ODU
P/N

732-251/08

Ext.

Rx FREQ.
(MHz)

Reference: Rec. ITU-R 386-6

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Associated
RF group
(non
extended
ODU)

Annex 3
Diplexer filter

P/N

Ext.

001

8279-8314

8405-8440

650

003

8286-8321

8412-8447

651

005

8293-8328

8419-8454

652

007

8300-8335

8426-8461

009

8307-8342

8433-8468

654

011

8314-8349

8440-8475

655

013

8321-8356

8447-8482

656

015

8328-8363

8454-8489

017

8335-8370

8461-8496

002

8405-8440

8279-8314

004

8412-8447

8286-8321

006

8419-8454

8293-8328

008

8426-8461

8300-8335

010

8433-8468

8307-8342

654

012

8440-8475

8314-8349

655
656

014

8447-8482

8321-8356

016

8454-8489

8328-8363

018

8461-8496

8335-8370

527-705/73

523-410/29

602-011/95
(732-251/08)

527-705/74

653

Mounting
type

Reverse(*)
(B)

657
658
650
651
652

527-705/73

527-705/74

653

Standard(*)
(A)

657
658

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-106

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.75

ODU (8.275-8.5 GHz) composition; Fs=119 MHz


8.275-8.5 GHz

FREQUENCY SHIFTER - 119 MHz (first digit Ext.= 1)


Tx FREQ.
(MHz)

ODU
P/N

732-251/08

Ext.

Rx FREQ.
(MHz)

Reference: Rec. ITU-R 386-6

TF
MIN

TF
MAX

Modem

Associated
RF group
(non
extended
ODU)

Annex 3
Diplexer filter

P/N

Ext.

101

8279-8314

8398-8433

050

103

8286-8321

8405-8440

051

105

8293-8328

8412-8447

052

107

8300-8335

8419-8454

053

109

8307-8342

8426-8461

054

111

8314-8349

8433-8468

055

113

8321-8356

8440-8475

056

115

8328-8363

8447-8482

057

117

8335-8370

8454-8489

058

119

8342-8377

8461-8496

102

8398-8433

8279-8314

104

8405-8440

8286-8321

051

106

8412-8447

8293-8328

052

108

8419-8454

8300-8335

053

110

8426-8461

8307-8342

054

112

8433-8468

8314-8349

055

114

8440-8475

8321-8356

056

116

8447-8482

8328-8363

057

118

8454-8489

8335-8370

058

120

8461-8496

8342-8377

059

523-410/29

602-011/95
732-251/08)

527-705/78

Mounting
type

Reverse(*)
(B)

059
050

Standard(*)
(A)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-107

2 - PLANNING

2.3.15.11 13 GHz ODU ND


Tab. 2.76

ODU (12.75 - 13.25 GHz) composition; Fs=266 MHz


12.75 - 13.25 GHz

FREQUENCY SHIFTER - 226 MHz (first digit Ext.= 0) Reference: Rec. ITU-R F.497
ODU
Rx FREQ. (MHz)
P/N

732-251/13

2-108

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

002

13016

13087

12750 - 12821

001

004

13059

13143

12793 - 12877

002

006

13115

13199

12849 - 12933

003

008

13171

13250

12905 - 12984

001

12750

12821

13016 - 13087

003

12793

12877

13059 - 13143

002

005

12849

12933

13115 - 13199

003

007

12905

12984

13171 - 13250

004

523-410/29

602-011/68

527-904/93

Mounting
type

Standard(*)
(A)

004
001
Standard(*)
(B)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.3.15.12 15 GHz ODU ND


Tab. 2.77

ODU (14.5 - 15.4 GHz) composition; Fs=336 MHz


14.4 - 15.4 GHz

FREQUENCY SHIFTER - 336 MHz (first digit Ext.= 0) Reference: Rec. ITU-R F.636
ODU
Rx FREQ. (MHz)
P/N

732-251/15

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

002

14931

15015

14595 - 14679

011

004

14978

15062

14642 - 14726

012

006

15025

15109

14689 - 14773

008

15072

15156

14736 - 14820

010

15119

15203

14783 - 14867

012

15162

15246

14826 - 14910

001

14595

14679

14931 - 15015

003

14642

14726

14978 - 15062

005

14689

14773

15025 - 15109

007

14736

14820

15072 - 15156

009

14783

14867

15119 - 15203

015

011

14826

14910

15162 - 15246

016

602-011/66
(732-251/15L)

527-904/76

013
014

Mounting
type

Standard(*)
(A)

015
016

523-410/29

011
012
602-011/67
(732-251/15H)

527-904/76

013
014

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).
Tab. 2.78

ODU (14.5 - 15.4 GHz) composition; Fs=420 MHz


14.4 - 15.4 GHz

FREQUENCY SHIFTER - 420 MHz (first digit Ext.= 1) Reference: Rec. ITU-R F.636
ODU
Rx FREQ. (MHz)
P/N

732-251/15

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

102

14920

15035

14500 - 14615

104

14999

15114

14579 - 14694

106

15078

15193

14658 - 14773

108

15157

15272

14737 - 14852

110

15235

15350

14815 - 14930

101

14500

14615

14920 - 15035

103

14579

14694

14999 - 15114

105

14658

14773

15078 - 15193

107

14737

14852

15157 - 15272

109

14815

14930

15235 - 15350

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

Mounting
type

111
602-011/66
(732-251/15L)

112
527-904/76 113
114

Standard(*)
(A)

115

523-410/29

111
602-011/67
(732-251/15H)

112
527-904/76 113
114

Reverse(*)
(B)

115

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-109

2 - PLANNING

Tab. 2.79

ODU (14.5 - 15.4 GHz) composition; Fs=728 MHz


14.4 - 15.4 GHz

FREQUENCY SHIFTER - 728 MHz (first digit Ext.= 4) Reference: Rec. ITU-R F.636
ODU
Rx FREQ. (MHz)
P/N

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

402

15229

15348

14501 - 14620

401

14501

14620

15229 - 15348

732-251/15

Modem

523-410/29

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

Mounting
type

602-011/66
(732-251/15L)

527-904/75 401

Standard(*)
(A)

602-011/67
(732-251/15H)

527-904/75 401

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

Tab. 2.80

ODU (14.5 - 15.4 GHz) composition; Fs=490 MHz


14.4 - 15.4 GHz

FREQUENCY SHIFTER - 490 MHz (first digit Ext.= 5) Reference: Rec. ITU-R F.636
ODU
Rx FREQ. (MHz)
P/N

732-251/15

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

502

14893

15012

14403 - 14522

504

14977

15096

14487 - 14606

506

15061

15180

14571 - 14690

508

15145

15264

14655 - 14774

510

15229

15348

14739 - 14858

501

14403

14522

14893 - 15012

503

14487

14606

14977 - 15096

505

14571

14690

15061 - 15180

507

14655

14774

15145 - 15264

509

14739

14858

15229 - 15348

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

Mounting
type

511
602-011/66
(732-251/15L)

512
527-904/75 513

Standard(*)
(A)

514
515

523-410/29

511
602-011/67
(732-251/15H)

512
527-904/75 513
514

Reverse(*)
(B)

515

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-110

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.81

ODU (14.5 - 15.4 GHz) composition; Fs=315 MHz


14.4 - 15.4 GHz

FREQUENCY SHIFTER - 315 MHz (first digit Ext.= 6) Reference: Rec. ITU-R F.636
ODU
Rx FREQ. (MHz)
P/N

732-251/15

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

602

14941

15021

14626 - 14706

601

604

14993

15073

14678 - 14758

602

606

15045

15125

14730 - 14810

608

15097

15177

14782 - 14862

610

15149

15229

14834 - 14914

601

14626

14706

14941 - 15021

603

14678

14758

14993 - 15073

605

14730

14810

15045 - 15125

607

14782

14862

15097 - 15177

609

14834

14914

15149 - 15229

602-011/66
(732-251/15L)

527-904/76 603
604

Mounting
type

Standard(*)
(A)

605

523-410/29

601
602-011/67
(732-251/15H)

602
527-904/76 603
604

Reverse(*)
(B)

605

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

Tab. 2.82

ODU (14.5 - 15.4 GHz) composition; Fs=322 MHz


14.4 - 15.4 GHz

FREQUENCY SHIFTER - 322 MHz (first digit Ext.= 7) Reference: Rec. ITU-R F.636
ODU
P/N

732-251/15

Rx FREQ. (MHz)

Tx FREQ.
(MHz)
TF
MIN

Ext.

TF
MAX

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

702

14949

15029

14627 - 14707

701

704

15001

15081

14679 - 14759

702

706

15053

15133

14731 - 14811

708

15105

15185

14783 - 14863

710

15157

15237

14835 - 14915

701

14627

14707

14949 - 15029

703

14679

14759

15001 - 15081

705

14731

14811

15053 - 15133

707

14783

14863

15105 - 15185

709

14835

14915

15157 - 15237

602-011/66
(732-251/15L)

527-904/76 703

Mounting
type

Standard(*)
(A)

704
705

523-410/29

701
602-011/67
(732-251/15H)

702
527-904/76 703
704

Reverse(*)
(B)

705

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-111

2 - PLANNING

2.3.15.13 18 GHz ODU ND


Tab. 2.83

ODU (17.7 - 19.7 GHz) composition; Fs=340 MHz


17.7 - 19.7 GHz

FREQUENCY SHIFTER - 340 MHz (first digit Ext.= 0) Reference: Rec. ITU-R F.595
ODU
Rx FREQ. (MHz)
P/N

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

002

18915

19057

18575 - 18717

602-011/64
(732-251/18L)

527-904/89

004

19023

19165

18683 - 18825

602-011/64
(732-251/18L)

527-904/90

732-251/18

523-410/29
001

18575

18717

18915 - 19057

602-011/65
(732-251/18H)

527-904/89

003

18683

18825

19023 - 19165

602-011/65
(732-251/18H)

527-904/90

Mounting
type

Standard(*)
(A)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

Tab. 2.84

ODU (17.7 - 19.7 GHz) composition; Fs=1010 MHz


17.7 - 19.7 GHz

FREQUENCY SHIFTER - 1010 MHz (first digit Ext.= 1) Reference: Rec. ITU-R F.595
ODU
Rx FREQ. (MHz)
P/N

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

102

18710

19219

17700 - 18209

602-011/64
(732-251/18L)

527-904/72

104

19191

19700

18181 - 18690

602-011/64
(732-251/18L)

527-904/73

732-251/18

523-410/29
101

17700

18209

18710 - 19219

602-011/65
(732-251/18H)

527-904/72

103

18181

18690

19191 - 19700

602-011/65
(732-251/18H)

527-904/73

Mounting
type

Standard(*)
(A)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-112

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Tab. 2.85

ODU (17.7 - 19.7 GHz) composition; Fs=1560 MHz


17.7 - 19.7 GHz

FREQUENCY SHIFTER - 1560 MHz (first digit Ext.= 3) Reference: Rec. ITU-R F.595
ODU
Rx FREQ. (MHz)
P/N

Ext.
302

19266

19694

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

17706 - 18134

732-251/18

523-410/29
301

17706

18134

19266 - 19694

Associated
RF group
(non extended
ODU)

Diplexer filter

Mounting
type

P/N

Ext.

602-011/64
(732-251/18L)

527-904/91

Standard(*)
(A)

602-011/65
(732-251/18H)

527-904/91

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2.3.15.14 23 GHz ODU ND

Tab. 2.86

ODU (21.2 - 23.6 GHz) composition; Fs=1008 MHz


21.2 - 23.6 GHz

FREQUENCY SHIFTER - 1008 MHz (first digit Ext.= 0) Reference: Rec. ITU-R F.637
ODU
P/N

Tx FREQ. (MHz)
Ext.

Rx FREQ. (MHz)

TF MIN

TF
MAX

Modem

002 23010.75 - 23598.75 22002.75-22590.75


732-251/23

523-410/29
001 22002.75 - 22590.75 23010.75-23598.75

Associated
RF group
(non
extended
ODU)

Annex 1

Diplexer filter
P/N

Mounting
type
Ext.

602-011/62
527-904/77
(732-251/23L)

Standard(*)
(A)

602-011/63
527-904/77
(732-251/23H)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-113

2 - PLANNING

Tab. 2.87

ODU (21.2 - 23.6 GHz) composition; Fs=1232 MHz


21.2 - 23.6 GHz

FREQUENCY SHIFTER - 1232 MHz (first digit Ext.= 1) Reference: Rec. ITU-R F.637
ODU
Rx FREQ. (MHz)
P/N

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Associated
RF group
(non extended
ODU)

Annex 1

Diplexer filter
P/N

Ext.

102

22432

23030

21200 - 21798

602-011/62
(732-251/23L)

527-904/78

104

22986

23600

21770 - 22368

602-011/62
(732-251/23L)

527-904/79

732-251/18

523-410/29
101

21200

21798

22432 - 23030

602-011/63
(732-251/23H)

527-904/78

103

21770

22368

22986 - 23600

602-011/63
(732-251/23H)

527-904/79

Mounting
type

Standard(*)
(A)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

Tab. 2.88

ODU (21.2 - 23.6 GHz) composition; Fs=1200 MHz


21.2 - 23.6 GHz

FREQUENCY SHIFTER - 1200 MHz (first digit Ext.= 2) Reference: Rec. ITU-R F.637
ODU
Rx FREQ. (MHz)
P/N

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Associated
RF group
(non extended
ODU)

Annex 1

Diplexer filter
P/N

Ext.

202

22400

23014

21200 - 21814

602-011/62
(732-251/23L)

527-904/78

204

22986

23600

21786 - 22400

602-011/62
(732-251/23L)

527-904/79

732-251/18

523-410/29
201

21200

21814

22400 - 23014

602-011/63
(732-251/23H)

527-904/78

203

21786

22400

22986 - 23600

602-011/63
(732-251/23H)

527-904/79

Mounting
type

Standard(*)
(A)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-114

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

2.3.15.15 26 GHz ODU ND


Tab. 2.89

ODU (24.5 - 26.5 GHz) composition; Fs=1008 MHz


24.5 - 26.5 GHz

FREQUENCY SHIFTER - 1008 MHz (first digit Ext.= 0) Reference: Rec. ITU-R F.748
ODU
Rx FREQ. (MHz)
P/N

Ext.

Tx FREQ.
(MHz)
TF
MIN

Modem

TF
MAX

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

002

25557

26019

24549 - 25011

602-011/70
(732-251/26L)

527-904/18

004

25991

26453

24983 - 25445

602-011/70
(732-251/26L)

527-904/19

732-251/26

523-410/29
001

24549

25011

25557 - 26019

602-011/70
(732-251/26H)

527-904/18

003

24983

25445

25991 - 26453

602-011/70
(732-251/26H)

527-904/19

Mounting
type

Standard(*)
(A)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2.3.15.16 28 GHz ODU ND


Tab. 2.90

ODU (27.5 - 29.5 GHz) composition; Fs=1008 MHz


27.5 - 29.5 GHz

FREQUENCY SHIFTER - 1008 MHz (first digit Ext.= 0) Reference: Rec. ITU-R F.748 Annex 2
Tx FREQ.
(MHz)

ODU
Rx FREQ. (MHz)
P/N

732-251/28

Ext.

TF
MIN

TF
MAX

002

28556.5

29018.5 27548.5-28010.5

004

28990.5

29452.5 27982.5-28444.5

001

27548.5

28010.5 28556.5-29018.5

003

27982.5

28444.5 28990.5-29452.5

Modem

Associated
RF group
(non
extended
ODU)

Diplexer filter
P/N
527-904/70

523-410/29

602-011/72

527-904/71
527-904/70
527-904/71

Ext.

Mounting
type

Standard(*)
(A)
Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-115

2 - PLANNING

2.3.15.17 38 GHz ODU ND


Tab. 2.91

ODU (37 - 39.5 GHz) composition; Fs=1260 MHz


37 - 39.5 GHz

FREQUENCY SHIFTER - 1260 MHz (first digit Ext.= 0) Reference: Rec. ITU-R F.749
ODU
Rx FREQ. (MHz)
P/N

Ext.

Tx FREQ.
(MHz)
TF
MIN

TF
MAX

Modem

Associated
RF group
(non extended
ODU)

Diplexer filter
P/N

Ext.

002

38318

38892

37058 - 37632

602-011/38
( 732-251/38L )

527-904/85

004

38864

39438

37604 - 38178

602-011/38
( 732-251/38L )

527-904/86

732-251/38

523-410/29
001

37058

37632

38318 - 38892

602-011/48
( 732-251/38H )

527-904/85

003

37604

38178

38864 - 39438

602-011/48
( 732-251/38H )

527-904/86

Mounting
type

Standard(*)
(A)

Reverse(*)
(B)

(*) These two diplexers are adjusted in the same sub-band, but are installed inside the
ODU in two different mounting position (standard and reverse).

2-116

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2 - PLANNING

Fig. 2.44

7, 8, 13, 15, 18, 23, 26, 28 and 38 GHz ODU ND: Diplexer position according to the
mounting type (A or B)

MOUNTING A DIPLEXER POSITION

MOUNTING B DIPLEXER POSITION

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

2-117

LA

PA
G
E

2 - PLANNING

2-118

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3 INSTALLATION
3.1 GENERAL
In this chapter all the operations are described, required for the mechanical installation
of SRAL XD equipments.
.
During the installation, while lifting the antenna and/or the outdoor pole
supporting frame, it is strictly forbidden to stand or transit in the area below; the
area has to be suitably delimited or signaled according to regulations in force.
For the operations to be realized outside on antenna, frame, ODU, all the required
safeties, according to the regulations in force, against accidental falls of the
operators have to be observed like the presence ot railings, safety bolts, etc..

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-1

3 - INSTALLATION

3.2 ODU FRAMES (7, 8 and 38 GHz)


3.2.1
Fig. 3.1

1+0 vertical frame dimensions with independent antenna


(7, 8 and 38 GHz ODU)
1+0 vertical frame dimensions with independent antenna
Pole with diam.
75 to 115 mm

Se
et
ab
le

Se
e

1+0 Frame

tab
le

ODU

(a)

3-2

ND

HD/ND

7/8

120

284

1538

80

230

244

Overall dimensions including ODU.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.2.1.1

1+0 vertical frame - Flange types and part numbers

Tab. 3.1

1+0 vertical frame - Flange types and part numbers


RF Band
(GHz)

1+0 frame
(P/N)

Frame flange
(to Antenna)

534-108/69

UDR 84

534-108/69

UDR 84

13

534-108/71

UBR 120

15

534-108/72

UBR 140

18

534-108/73

UBR 220

23

534-108/73

UBR 220

26

534-108/73

UBR 220

28

534-108/74

UBR 320

38

534-108/74

UBR 320

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-3

3 - INSTALLATION

3.2.1.2

1+0 vertical frame - Pole mounting

Fig. 3.2

1+0 vertical frame - Pole mounting


Pole with diam.
75 to 115 mm

U-BOLT

1+0 Frame

Safety collar

3-4

Install first the safety collar.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.2.1.3

1+0 vertical frame - Wall mounting

Fig. 3.3

1+0 vertical frame - Wall mounting

Insert
TASSELLO

1+0 Frame
TELAIO
1+0

*=

The inserts are not delivered with the frame, if this fixing is required they have to be separately
provided.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-5

3 - INSTALLATION

3.2.1.4

1+0 vertical frame - O-rings

Fig. 3.4

1+0 vertical frame - O-rings

Protection cover
and O-ring

O-ring

Protection cover

(*)

3-6

The O-ring are delivered with the frame.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.2.2
Fig. 3.5

1+1 vertical frame dimensions with independent antenna


(7/8 GHz ODU)
1+1 vertical frame dimensions with independent antenna

Pole with diam.


75 to 115 mm

Se
et
ab
le

Se
et
ab
le

1+1 Frame

ODU (St.By)

ODU (Main)

A
7 to 13

(a)

120

ND

HD/ND

243

284

= Overall dimensions including ODU.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-7

3 - INSTALLATION

3.2.2.1

Attenuation values, flange types

Tab. 3.2

1+1 vertical frame - Attenuation values, flange types


1+1 Frame
frequency diversity
RF
Band
(GHz)

3-8

P/N

1+1 Frame
not balanced HSBY

Circulator
attenuation
(dB)

P/N

Coupler
attenuation
(dB)
MAIN

ST.BY

Flange
type
(to
antenna)

534-108/80

0.3

534-108/82

101.5

UDR 84

534-108/81

0.3

534-108/83

101.5

UDR 84

13

534-108/85

1.1

101.5

UBR 120

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.2.2.2

1+1 vertical frame - Pole mounting

Fig. 3.6

1+1 vertical frame - Pole mounting


U-BOLT

Pole with diam.


75 to 115 mm

1+1 Frame

Safety collar

Install first the safety collar.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-9

3 - INSTALLATION

3.2.2.3

1+1 vertical frame - Wall mounting

Fig. 3.7

1+1 vertical frame - Wall mounting

Insert
TASSELLO

1+1 Frame
TELAIO
1+1

*=

3-10

The inserts are not delivered with the frame, if this fixing is required they have to be separately
provided.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.2.2.4

1+1 vertical frame - O-rings

Fig. 3.8

1+1 vertical frame - O-rings

Protection cover
and O-ring

O-ring

Protection cover

(*)

The O-ring are delivered with the frame.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-11

3 - INSTALLATION

3.2.3
Fig. 3.9

1+1 vertical frame dimensions with independent antenna


(ODU 15 GHz to 38 GHz)
1+1 vertical frame dimensions with independent antenna

Pole with diam.


75 to 115 mm

ODU
(St.By)
1+1 Frame

Main
ODU

3-12

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.2.3.1

Attenuation values, flange types

Tab. 3.3

1+1 support frame with independent antenna - Attenuation values, flange types
1+1 Frame
not balanced HSBY
RF
Band
(GHz)

P/N

Coupler
attenuation
(dB)
MAIN

ST.BY

1+1 Frame
balanced HSBY

P/N

Coupler
attenuation
(dB)

Flange
type
(to
antenna)

15

534-121/01

1.3

101

534-121/11

30.3

UBR 140

18

534-121/02

1.3

101

534-121/12

30.3

UBR 220

23

534-121/03

1.3

101

534-121/13

30.3

UBR 220

26

534-121/04

1.3

101

534-121/14

30.3

UBR 220

28

534-121/05

1.3

101

534-121/15

30.3

UBR 320

38

534-121/06

1.3

101

534-121/16

30.3

UBR 320

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-13

3 - INSTALLATION

3.2.3.2

1+1 vertical frame with independent antenna (15 GHz to 38 GHz


ODU) - Pole mounting

Fig. 3.10

1+1 vertical frame with independent antenna (15 GHz to 38 GHz ODU) - Pole
mounting

Pole with diam.


75 to 115 mm

1+1 Frame
Safety collar

3-14

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.2.3.3

1+1 vertical frame with independent antenna (15 GHz to 38 GHz


ODU) - Wall mounting

Fig. 3.11

1+1 vertical frame with independent antenna (15 GHz to 38 GHz ODU) - Wall
mounting

Insert

1+1 Frame

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-15

3 - INSTALLATION

3.2.3.4
Fig. 3.12

1+1 vertical frame with independent antenna (15 GHz to 38 GHz


ODU) - O-rings
1+1 vertical frame with independent antenna (15 GHz to 38 GHz ODU) - O-rings

Protection cover
and O-ring

O-ring

Protection cover

3-16

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.2.4
Fig. 3.13

1+1 vertical frame dimensions with integrated antenna


(15 GHz to 38 GHz ODU)
1+1 vertical frame dimensions with integrated antenna
ODU
MAIN

550 m m

Pole with diam.


75 to 115 mm

ODU
STBY

320 mm

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

ODU safety
hook

3-17

3 - INSTALLATION

3.2.4.1

Attenuation values, flange types

Tab. 3.4

1+1 support frame with integrated antenna - Attenuation values, flange types
1+1 Frame
not balanced HSBY
RF
Band
(GHz)

3-18

P/N

Coupler
attenuation
(dB)
MAIN

ST.BY

1+1 Frame
balanced HSBY

P/N

Coupler
attenuation
(dB)

Flange
type
(to
antenna)

15

534-120/01

1.3

101

534-120/11

30.3

UBR 140

18

534-120/02

1.3

101

534-120/12

30.3

UBR 220

23

534-120/03

1.3

101

534-120/13

30.3

UBR 220

26

534-120/04

1.3

101

534-120/14

30.3

UBR 220

28

534-120/05

1.3

101

534-120/15

30.3

UBR 320

38

534-120/06

1.3

101

534-120/16

30.3

UBR 320

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

Fig. 3.14

1+1 vertical frame with integrated antenna - Polarization change

POLARIZATION CHANGE

VERTICAL POLARIZATION

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

HORIZONTAL POLARIZATION

3-19

3 - INSTALLATION

3.2.4.2
Fig. 3.15

1+1 vertical frame with integrated antenna - O-rings


1+1 vertical frame with integrated antenna - O-rings

Protection
cover

O-ring

Protection cover
and O-ring

3-20

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.3 NOT INTEGRATED SYSTEM (SOLUTION


WITH FLEXIBLE WAVEGUIDE)
3.3.1
Fig. 3.16

Connections
Connections (solution with flexible waveguide)

P
VERTICAL
POLARIZATION

U
P
U

HORIZONTAL
POLARIZATION
POLE 75 to 115mm
(recommended 115mm)

(**)

POLE FIXING
FOR
FLEXIBLE
WAVEGUIDE
(*)

FLEXIBLE
WAVEGUIDE

1+0 VERTICAL FRAME (7 to 38 GHz ODU)


1+1 VERTICAL FRAME (7/8 GHz ODU)
1+1 SUPPORT FRAME (15 to 38 GHz ODU)

P = PRESSURIZABLE FLANGE
U = UNPRESSURIZABLE FLANGE
*=
for the P/N of these accessories see Tab. 3.5.
**=
it is delivered in quantity of 1 with the 0.6 m. flexible waveguide and quantity of 2 with the 1m. guide.
For the overall size see PAR. 3.3.3.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-21

3 - INSTALLATION

3.3.2

Tab. 3.5

Attenuation and P/N

Attenuation and P/N

RF
Band
(GHz)

Flexible waveguide kit


(L. = 600 mm) *

Flexible waveguide kit


(L. = 1000 mm) **

P/N

Attenuation
(dB)

P/N

Attenuation
(dB)

597-524/83
(UDR-PDR 84)

0.18

597-523/95
(UDR-PDR 84)

0.39

597-524/83
(UDR-PDR 84)

0.18

597-523/95
(UDR-PDR 84)

0.39

13

597-524/85
(UBR-PBR 120)
(c)

0.3

597-523/97
(UBR-PBR 120)
(c)

0.5

15

597-524/86
(UBR-PBR 140)
(c)

0.396

597-523/98
(UBR-PBR 140)
(c)

0.66

18

597-524/87
(UBR-PBR 220)

0.72

597-523/99
(UBR-PBR 220)

1.2

23

597-524/87
(UBR-PBR 220)

0.72

597-523/99
(UBR-PBR 220)

1.2

26

597-524/87
(UBR-PBR 220)

0.72

597-523/99
(UBR-PBR 220)

1.2

28

597-525/79
(UBR-PBR 320)

1.2

597-525/80
(UBR-PBR 320)

1.2

38

597-524/88
(UBR-PBR 320)

1.2

597-524/20
(UBR-PBR 320)

(a) = This flexible waveguide is used with antennas diameters up to 0.80 m (2.5 ft.).
(b) = This flexible waveguide is used with antennas diameters 1.2 m (4 ft.)
(c) = Special (UBR) flange

3-22

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.3.3
Fig. 3.17

Pole overall size


Pole overall size

1+0 SYSTEM WITH ANTENNA 1.2 m

1+1 SYSTEM WITH ANTENNA UP TO 60 cm

1+1 SYSTEM WITH ANTENNA 1.2 m

1200

1+0 SYSTEM WITH ANTENNA UP TO 60 cm

Dimensions in millimeters (mm)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-23

3 - INSTALLATION

3.4 NOT INTEGRATED SYSTEM (SOLUTION


WITH ELLIPTICAL WAVEGUIDE)
3.4.1
Fig. 3.18

Connections
Connections (solution with elliptical waveguide)
E BEND
90
VERTICAL
POLARIZATION
TWIST

HORIZONTAL POLARIZATION
POLE 75 to 115mm
(recommended 115mm)
WAVEGUIDE
SUPPORT

WAVEGUIDE
CONNECTOR

UNIVERSAL
CLAMP

PRESSURIZATION
WINDOW

ELLIPTICAL
WAVEGUIDE
1+0 VERTICAL FRAME
(ODU 7 to 38 GHz)
1+1 VERTICAL FRAME
(ODU 7/8 GHz)
1+1 SUPPORTING FRAME
(ODU 15 to 38 GHz)

RIGHT SECTION

PRESSURIZABLE FLANGE
UNPRESSURIZABLE FLANGE
*=

3-24

For the P/N of these accessories see PAR. 3.4.3. For the waveguide pressurization see PAR. 3.4.2
For the mounting of the ODUs inside a shelter or inside an equipment room, the waveguide must be
connected to ground before entering the shelter or equipment room

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.4.2

Fig. 3.19

Pressurization with external dehydrator

Pressurization with external dehydrator

WAVEGUIDE
CONNECTOR
ODU SIDE

EXTERNAL
DEHYDRATOR

DEHYDRATOR PIPE

It is recommended for waveguide run over :


5m (7 GHz), 6m (8 GHz), 9m (10 GHz), 11m (13 GHz), 16m (15 GHz), 25m (18 GHz),
38m (23 GHz) e 45m (26 GHz)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-25

3 - INSTALLATION

3.4.3

Elliptical flexible waveguide, connector and accessory


versions

Tab. 3.6

7 GHz

Elliptical wave guide (31263-750)


Item

Tab. 3.7

DESRIPTION

P/N

Unit

Q.ty

1a

Elliptical waveguide (EWP 64-71)

127-042/05

Mt.

Note 1-3

1b

Elliptical waveguide (EWP 77-71W)

127-042/14

Mt.

Note 1-4

Adapter for angular (10pz)

165-005/84

Note 1

3a

Waveguide clamp (10pz)

165-005/69

Note 1-3

3b

Waveguide clamp (10pz)

165-005/70

Note 1-4

P/N

Unit

Q.ty

Connectors and accessories (31263-778SR)


Item

DESRIPTION

a1

Waveguide connector EWP 64-71


(PDR 84)

504-237/99

2
Note 3

a2

Waveguide connector EWP 77-71W


(PDR 84)

504-237/87

2
Note 4

Pressurization window (UDR-UDR 84)

308-005/16

Waveguide support

332-055/21

Universal clamp ( 62)

165-005/19

f1

Rubber bush ( 62)

332-202/90

3
Note 3

f2

Rubber bush ( 62)

332-202/87

3
Note 4

90 E bend (UDR-UDR 84)

504-393/36

1
Note 5

Right section (PDR-PDR 84)

504-816/27

Twist (UDR-PDR 84)

504-631/21

1
Note 2

Adapter

504-216/21

1
Note 6

Note 1 = Quantity to be defined as per plant requirements.


Note 2 = Optional, use for horizontal polarization only.
Note 3 = For 7.1-7.4 GHz (shifter 161 MHz) and 7.4-7.7 GHz (shifter 154 MHz)
channelings
Note 4 = For 7.4-7.9 GHz (shifter 245 MHz) and 7.7-7.9 (shifter 148.5 MHz)
Note 5 = Supply with antennas 1.2 m.
Note 6 = Supply with antennas 1.8 m.

3-26

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

Tab. 3.8

8 GHz

Elliptical wave guide (31263-758)


Item

Tab. 3.9

DESRIPTION

P/N

Unit

Q.ty

Elliptical waveguide (EWP 77-77)

127-042/06

Mt.

Note 1

Adapter for angular (10pz)

165-005/84

Note 1

Waveguide clamp (10pz)

165-005/70

Note 1

P/N

Unit

Q.ty

Connectors and accessories (31263-779SR)


Item

DESRIPTION

Waveguide connector (PDR 84)

504-237/87

Pressurization window (UDR-UDR 84)

308-005/16

Waveguide support

332-055/21

Universal clamp ( 62)

165-005/19

Rubber bush ( 62)

332-202/87

90 E bend (UDR-UDR 84)

504-393/36

1
Note 3

Right section (PDR-PDR 84)

504-816/27

Twist (UDR-PDR 84)

504-631/21

1
Note 2

Adapter

504-216/21

1
Note 4

Note 1 = Quantity to be defined as per plant requirements.


Note 2 = Optional, use for horizontal polarization only.
Note 3 = Supply with antennas 1.2 m.
Note 4 = Supply with antennas 1.8 m.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-27

3 - INSTALLATION

Tab. 3.10

13 GHz

Elliptical wave guide (31263-766)


Item

Tab. 3.11

DESRIPTION

P/N

Unit

Q.ty

Elliptical waveguide (EWP 127)

127-042/08

Mt.

Note 1

Adapter for angular (10pz)

165-005/84

Note 1

Waveguide clamp (10pz)

165-005/72

Note 1

P/N

Unit

Q.ty

Connectors and accessories (31263-781SR)


Item

DESRIPTION

Waveguide connector (PBR 120)

504-237/97

Waveguide support

332-055/21

Universal clamp ( 38)

165-005/17

Rubber bush ( 38)

332-202/83

90 E bend (UBR-UBR 120)

504-446/68K

1
Note 3

Twist (UBR-PBR 120)

504-656/52K

1
Note 2

504-216/23

1
Note 4

Adapter

Note 1 = Quantity to be defined as per plant requirements.


Note 2 = Optional, use for horizontal polarization only.
Note 3 = Supply with antennas 1.2 m.
Note 4 = Supply with antennas 1.8 m.

3-28

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

Tab. 3.12

15 GHz

Elliptical wave guide (31263-767)


Item

Tab. 3.13

DESRIPTION

P/N

Unit

Q.ty

Elliptical waveguide (EWP 132)

127-042/09

Mt.

Note 1

Adapter for angular (10pz)

165-005/84

Note 1

Waveguide clamp (10pz)

165-005/70

Note 1

Connectors and accessories (31263-782SR)


Item

DESRIPTION

P/N

Unit

Q.ty

Waveguide connector (PBR 140)

504-237/96

Pressurization window (UBR-UBR 140)

308-005/22

Waveguide support

332-055/21

Universal clamp ( 38)

165-005/17

Rubber bush ( 38)

332-202/82

90 E bend (UBR-UBR 140)

504-446/69K

Right section (PBR-PBR 140)

504-816/30

Twist (UBR-PBR 140)

504-656/53K

1
Note 2

Note 1 = Quantity to be defined as per plant requirements.


Note 2 = Optional, use for horizontal polarization only.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-29

3 - INSTALLATION

Tab. 3.14

18 GHz

Elliptical wave guide (31263-768)


Item

Tab. 3.15

DESRIPTION

P/N

Unit

Q.ty

Elliptical waveguide (EWP 180)

127-042/10

Mt.

Note 1

Adapter for angular (10pz)

165-005/84

Note 1

Waveguide clamp (10pz)

165-005/70

Note 1

Connectors and accessories (31263-783SR)


Item

DESRIPTION

P/N

Unit

Q.ty

Waveguide connector (PBR 220)

504-237/94

Pressurization window (UBR-UBR 220)

308-005/21

Waveguide support

332-055/21

Universal clamp ( 38)

165-005/17

Rubber bush ( 38)

332-202/84

90 E bend (UBR-UBR 220)

504-446/70K

Right section (PBR-PBR 220)

504-816/31

Twist (UBR-PBR 220)

504-656/54K

1
Note 2

Note 1 = Quantity to be defined as per plant requirements.


Note 2 = Optional, use for horizontal polarization only.

3-30

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

Tab. 3.16

23 GHz

Elliptical wave guide (31263-769)


Item

Tab. 3.17

DESRIPTION

P/N

Unit

Q.ty

Elliptical waveguide (EWP 220)

127-042/11

Mt.

Note 1

Adapter for angular (10pz)

165-005/84

Note 1

Waveguide clamp (10pz)

165-005/74

Note 1

P/N

Unit

Q.ty

Connectors and accessories (31263-784SR)


Item

DESRIPTION

Waveguide connector (PBR 220)

504-237/92

Pressurization window (UBR-UBR 220)

308-005/21

Waveguide support

332-055/21

Universal clamp ( 38)

165-005/17

Rubber bush ( 38)

332-202/85

90 E bend (UBR-UBR 220)

504-446/70K

Right section (PBR-PBR 220)

504-816/31

Twist (UBR-PBR 220)

504-656/54K

1
Note 2

Note 1 = Quantity to be defined as per plant requirements.


Note 2 = Optional, use for horizontal polarization only.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-31

3 - INSTALLATION

Tab. 3.18

26 GHz

Elliptical wave guide (31263-771)


Item

Tab. 3.19

DESRIPTION

P/N

Unit

Q.ty

Elliptical waveguide (EWP 240)

127-042/13

Mt.

Note 1

Adapter for angular (10pz)

165-005/84

Note 1

Waveguide clamp (10pz)

165-005/74

Note 1

P/N

Unit

Q.ty

Connectors and accessories (31263-785R)


Item

DESRIPTION

Waveguide connector (PBR 220)

504-237/95

Pressurization window (UBR-UBR 220)

308-005/21

Waveguide support

332-055/21

Universal clamp ( 38)

165-005/17

Rubber bush ( 38)

332-202/89

90 E bend (UBR-UBR 220)

504-446/70K

Right section (PBR-PBR 220)

504-816/31

Twist (UBR-PBR 220)

504-656/54K

1
Note 2

Note 1 = Quantity to be defined as per plant requirements.


Note 2 = Optional, use for horizontal polarization only.

3-32

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.5 ODU
3.5.1
Fig. 3.20

Assembly on support frame


ODU assembly on support frame

OUTDOOR assembly
(see par. 3.5.2)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-33

3 - INSTALLATION

3.5.2

ODU dimensions

3.5.2.1

ODU Normal Density (ND) dimensions

Fig. 3.21

ODU Normal Density (ND) dimensions

Grounding screw
BOTTOM VIEW

281

SIDE VIEW

FRONT VIEW

Rx field
measure
connector

238

267

123

IN/OUT cable
connector

Weight of the OUTDOOR assembly = 4.3 kg

3-34

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.5.2.2
Fig. 3.22

ODU High Density (HD) dimensions


ODU High Density (HD) dimensions

Rx field measure
connector
BOTTOM VIEW

IN/OUT cable
connector

FRONT VIEW

SIDE VIEW

290
269

164

238

155

232

140

For feeder
flange

Handle

Grounding
point

Weight of the OUTDOOR assembly = 7.5 kg

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-35

3 - INSTALLATION

3.5.3

Tab. 3.20

3-36

ODU versions

ODU versions
Frequency
Band
(GHz)

Frequency shifter
(MHz)

7
(7.1 to 7.9)

P/N ODU type


ND

HD/HP

Feeder
Flange

148.5 / 154 / 161 /


168 / 245 / 196

732-251/07

732-241/07

UDR 84

8
(7.7 to 8.5)

119 / 126 /
311.25

732-251/08

732-241/08

UDR 84

13
(12.5 to 13.25)

266

732-251/13

UBR 120

15
(14.5 to 15.35)

315 / 322 / 336 / 420 /


490 / 644 / 714 / 728

732-251/15

732-241/15

UBR 140

18
(17.7 to 19.7)

120 / 340 / 1010 /


1560

732-251/18

732-241/18

UBR 220

23
(21.2 to 23.6)

1008 / 1200 / 1232

732-251/23

732-241/23

UBR 220

26
(24.5 to 26.5)

1008

732-251/26

732-241/26

UBR 220

28
(27.5 to 29.5)

1008

732-251/28

732-241/28

UBR 320

38
(37.0 to 39.5)

1260

732-251/38

732-451/38

UBR 320

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.5.4
Fig. 3.23

Vertical polarization application


Vertical polarization application (ODU Normal Density - ND)

Rx field measure
connector

REAR VIEW

Ground

IN/OUT cable
connector

Note = for vertical polarised application, the IN/OUT cable connector is at bottom.

Fig. 3.24

Vertical polarization application (ODU High Density - HD)

Ground

Rx field measure
connector

REAR VIEW

IN/OUT cable
connector
Note = for vertical polarised application, the IN/OUT cable connector is at bottom.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-37

3 - INSTALLATION

3.5.5
Fig. 3.25

Horizontal polarization application


Horizontal polarization application (ODU Normal Density - ND)
IN/OUT cable
connector

REAR VIEW
Ground

Rx field measure
connector
Note = for horizontal polarised application, the IN/OUT cable connector is on the right side.

Fig. 3.26

Horizontal polarization application (ODU High Density - HD)

IN/OUT cable
connector
Rx field measure
connector

REAR VIEW
Ground

Note = for horizontal polarised application, the IN/OUT cable connector is on the right side.

3-38

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.5.6
Fig. 3.27

Rx field measure connector


Rx field measure connector

(*)

Rx field measure
connector
BNC socket

(*) This Rx field measure connector is the test point for the connection of a voltmeter
during the antenna alignment procedure.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-39

3 - INSTALLATION

3.6 IDU/ODU CONNECTION WITH BRAIDED


COAXIAL CABLE
3.6.1
Fig. 3.28

IDU/ODU typical connection with Braided coaxial cable


Braided coaxial cable - IDU/ODU tipical connection

Coaxial connector
90 N type

Braided IN/OUT
coaxial cable

Coaxial connector
90 SMA type
IDU ASSEMBLY

Note = The max lenght of one IDU/ODU connection is 200 mt.

3-40

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.6.2
Fig. 3.29

Grounding connections, integrated solution


Grounding connections, integrated solution

(*) (**)

Grounding
kit

Braided coaxial
cable

Ground cable
1x16 mm2
PVC YE-GR
(103-037/50)

(****)

(*****)

(*) (***)

Grounding plate
333-047/07

General
grounding point
Braided coaxial
cable

(*) (**)

INDOOR

Bending radius
Braided coaxial
cable

(*) (**)

To connect to the
station grounding
system
(*)
(**)
(***)

For P/N of these accessories see PAR. 3.7.8.


For the fixing of the Braided coaxial cable see Fig. 3.32.
The standard delivery includes only one grounding kit to be installed before the entrance of the shelter/
equipment room. Additional grounding kits are provided on demand.
(****) This cable is provided with the installation kits (597-523/85..86, 597-524/61..62).
(*****) Optional item, if required must be separately provided.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-41

3 - INSTALLATION

3.6.3
Fig. 3.30

Grounding connections, not integrated solution


Grounding connections, not integrated solution

(*) (**)

Grounding
kit

Braided coaxial
cable

Ground cable
1x16 mm2
PVC YE-GR
(103-037/50)

Grounding plate
(332-309/91)

(****)
(*****)

(*) (***)

Grounding plate
333-047/07

(*****)
(******)

General
grounding point

Braided coaxial
cable

(*) (**)

Bending radius
Braided coaxial
cable

(*) (**)

To connect to the
station grounding
system
(*)
For P/N of these accessories see PAR. 3.7.8.
(**)
For the fixing of the Braided coaxial cable see Fig. 3.32.
(***) The standard delivery includes only one grounding kit to be installed before the entrance of the shelter/
equipment room. Additional grounding kits are provided on demand.
(****) This cable is provided with the installation kits (597-523/85..86, 597-524/61..62).
(*****) To secure the plate see PAR. 3.6.4.
(******) Optional item, if required must be separately provided.

3-42

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.6.4
Fig. 3.31

Pole fixing of the grounding plate kit (P/N 332-309/91)


Pole fixing of the grounding plate kit (P/N 332-309/91)

25

50

32

Tie
223-002/86

(*)

Plate
332-004/92

(*)

Grouding plate
257-41/507

9
7

12

(*)

(*)

Hex nut
(*)
Spring washer
(*)

Plain washer

Screw

(*)

Terminal tube

16 mm2 or 25 mm2

(*)

Grounding cable
1x16 mm2 or 1x25 mm2
YE-GR

(*)

These materials are included in P/N 332-309/91.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-43

3 - INSTALLATION

3.6.5

Fig. 3.32

Braided coaxial cable - Typical fixing

Braided coaxial cable - Typical fixing

(b)

Cable tie
(223-009/27)

(a)

(a)

Universal
cable clamp
(332-202/95)
(332-202/96)
Cable tie
(223-009/27)

INDOOR

Braided coaxial cable

CABLE TIE (a)

UNIVERSAL CABLE CLAMP (b) (c)

External back cable tie


D = 74 to 140 mm 223-009/27 (*)
D = 26 to 62 mm 223-009/25 (**)

for 2 Braided cables


332-202/65
(a)
(b)

3-44

for 4 Braided cables


332-202/66

N 5 external black tie, for the fixing of the cable running on the pole, are included in the installation kit (314-205/76),
provided with the external connection accessories (1+0).
Material to be adopted according to the installation requirements, is not included in the installation materials,
if required must be separately provided. Refer to PAR. 3.6.5.1 for the recommended spacing.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.6.5.1

Recommended clamp spacing for Braided coaxial cable


Clamp spacing recommendation is based on the guidelines stated in EIA Standard
RS-222 (Structural Standards for Steel Antenna Towers and Antenna Supporting
Structures) and BSI CP3 (Code of Basic Data for the Design of Buildings, Wind
Loading).
Geographical location, as well as height of tower/must, to which the clamps are
attached, may have a significant impact on installation conditions.
Therefore, unless otherwise specified, the assumptions made to define the maximum
clamp spacing are the following:

Tower height 45m

1/2 radial ice

Clamps properly installed and tightened

Based on the above conditions, the recommended MAXIMUM CLAMP SPACING for
Braided COAXIAL CABLE type CNT 300FR (Andrew) and ICN48 (INTERCOND) is 0.5
m (wind load is 240 km/h)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-45

3 - INSTALLATION

3.6.6

Tab. 3.21

Andrew and Intercond sets

ANDREW set (a)

P/N

Description

104-009/50
314-331/88 (b)

Braided CNT300 - 50 Ohm COAXIAL CABLE

597-525/59A
597-525/59 (b)

BRAIDED COAX CABLE ACCESSORIES

Q.ty

Mt.

(c)

Nr.

(d)

421-025/30

90 COAX SMA-PLUG

300APSR-C

421-008/35

90 COAX N-PLUG

300APNR-C

333-031/21

GROUNDING KIT

KMT 7-P

Tab. 3.22

INTERCOND set (a)

P(N

Description

104-009/51
314-331/88 (b)

CF 3/10l3 ICN48 - 50 Ohm COAXIAL CABLE

597-525/59B
597-525/59 (b)

BRAIDED COAX CABLE ACCESSORIES

3-46

PNCNT300FR

Unit

PN14-RBC48/11M

Unit

Q.ty

Mt.

(c)

Nr.

(d)

421-025/31

90 COAX SMA-PLUG

050-611-9129310

421-008/36

90 COAX N-PLUG

057-011-9099890

333-031/22

GROUNDING KIT

2A48EOL-ICN/DS

a)

= The ANDREW and INTERCOND material sets are alternative to each other

b)

= Commercial reference code

c)

= The max length of one IDU/ODU connection is 200 mt

d)

= Q.ty 1 for each IDU/ODU connection

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.6.7

Tab. 3.23

Tab. 3.24

Characteristics

Construction characteristics

Diameter (mm)

1.78

1.78

Dielectric

Diameter (mm)

4.83

4.90

Outer Conductor

Diameter (mm)

4.98

6.00

Standard Jacket

Diameter (mm)

7.62

7.60

ANDREW

INTERCOND

0.08

0.095

> 22.2

> 25

Mechanical characteristics

Min. Bending Radius

(kg/m)
single bend (mm)

Tensile Strength

(kg)

120

50

Bending Moment

(N m)

0.52

(kg/mm)

0.54

ANDREW

INTERCOND

Crash Strength
Max. Standard Hanger Spacing

Tab. 3.26

INTERCOND

Inner Conductor

Weight

Tab. 3.25

ANDREW

(m)

Range of temperature

Recommended Temperature for Installation

(C)

- 40 / + 85

- 40 / + 85

Recommended Storage for Installation

(C)

- 70 / + 85

- 40 / + 85

Operating Temperature

(C)

- 40 / + 85

- 40 / + 85

ANDREW

INTERCOND

(ohm)

50

50

(%)

85

(pF/m)

79.10

(Mhz)

2450

(kW)

10

10

DC Resistance : Inner Conductor

(ohm/km)

6.9

7.20

DC Resistance : Outer Conductor

(ohm/km)

7.25

5.32

(V)

2000

(H/m)

0.20

0.20

Electrical characteristics

Characteristics Impedance
Relative Propagation Velocity
Capacitance
Maximun Operating Frequency
Peak Power Rating

DC Breakdown
Inductance

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-47

3 - INSTALLATION

Tab. 3.27

Tab. 3.28

Attenuation, (dB/100) Standard conditions: VSWR 1.0; ambient temperature 24C


ANDREW

INTERCOND

30 MHz

3.50

50 MHz

4.50

150 MHz

7.80

7.80

450 MHz

13.70

13.70

900 MHz

19.7

1500 MHz

25.70

1700 MHz

27.50

2000 MHz

30.0

2200 MHz

31.30

2300 MHz

33.9

23.1

Average Power Rating, kW Standard conditions : VSWR 1.0 ; ambient temperature


40C ; inner conductor temperature 100C ;
ANDREW

3-48

INTERCOND

30 MHz

2.10

50 MHz

1.60

150 MHz

0.92

450 MHz

0.52

900 MHz

0.36

1500 MHz

0.28

2000 MHz

0.24

2300 MHz

0.22

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.7 IDU/ODU CONNECTION WITH 1/4 COAXIAL


CABLE
3.7.1
Fig. 3.33

IDU/ODU typical connection with 1/4 coaxial cable


1/4 coaxial cable - IDU/ODU tipical connection

1/4 IN/OUT
coaxial cable

IDU
ASSEMBLY
IDU ASSEMBLY

Note = The max lenght of one IDU/ODU connection is 300 mt.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-49

3 - INSTALLATION

3.7.2
Fig. 3.34

ODU side connection


1/4 coaxial cable - ODU side connection

(FRONTAL
SIDE)
(FRONT VIEW)

90 coax N-plug

1/4 coaxial cable

(*)

To IDU
section

(*) For the P/N of these accessories see par. 3.7.8

3-50

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.7.3
Fig. 3.35

Grounding connections, integrated solution


Grounding connections, integrated solution
(*) (**)

Grounding
kit

1/4 coaxial
cable

Ground cable
1x16 mm2
PVC YE-GR
(103-037/50)

(****)
(*****)

(*) (***)

Grounding plate
333-047/07

General
grounding point

1/4 coaxial
cable

(*) (**)

Bending radius
1/4 coaxial
cable

(*) (**)

To connect to the
station grounding
system
(*)
(**)
(***)

For P/N of these accessories see PAR. 3.7.8.


For the fixing of the 1/4" coaxial cable see Fig. 3.32.
The standard delivery includes only one grounding kit to be installed before the entrance of the shelter/
equipment room. Additional grounding kits are provided on demand.
(****) This cable is provided with the wiring kits.
(*****) Optional item, if required must be separately provided.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-51

3 - INSTALLATION

3.7.4
Fig. 3.36

Grounding connections, not integrated solution


Grounding connections, not integrated solution

(*) (**)

Grounding
kit

1/4 coaxial
cable

Ground cable
1x16 mm2
PVC YE-GR
(103-037/50)

Grounding plate
(332-309/91)

(****)
(*****)

(*) (***)

Grounding plate
333-047/07

(*****)
(******)

General
grounding point

1/4 coaxial
cable

(*) (**)

INDOOR

Bending radius
1/4 coaxial
cable

(*) (**)

To connect to the
station grounding
system
(*)
(**)
(***)

For P/N of these accessories see PAR. 3.7.8


For the fixing of the 1/4" coaxial cable see Fig. 3.32
The standard delivery includes only one grounding kit to be installed before the entrance of the shelter/
equipment room. Additional grounding kits are provided on demand.
(****) This cable is provided with the wiring kits (597-523/85..86, 597-524/61..62)
(*****) For the fixing of the ground plate see PAR. 3.6.4
(******) Optional item, if required must be separately provided.

3-52

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.7.5

Pole fixing of the grounding plate kit (P/N 332-309/91)

Fig. 3.37

Pole fixing of the grounding plate kit (P/N 332-309/91)

25

50

32

Tie
223-002/86

(*)

Plate
332-004/92

(*)

Grouding plate
257-41/507

12

(*)

Hex nut
(*)
Spring washer
(*)

Plain washer

Screw

(*)

(*)

Terminal tube

16 mm2 or 25 mm2

(*)

Grounding cable
1x16 mm2 or 1x25 mm2
YE-GR

(*)

These materials are included in P/N 332-309/91.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-53

3 - INSTALLATION

3.7.6

Fig. 3.38

1/4 coaxial cable - Typical fixing

1/4 coaxial cable - Typical fixing

Universal
cable clamp
(332-202/95)
(332-202/96)

(b)

Cable tie
(223-009/27)

(a)

(a)

Cable tie
(223-009/27)

INDOOR

1/4 Braided coaxial cable

CABLE TIE (a)

UNIVERSAL CABLE CLAMP (b) (c)

External back cable tie


D = 74 to 140 mm 223-009/27 (*)
D = 26 to 62 mm 223-009/25 (**)

for 2 1/4 cables


332-202/65
(a)
(b)

3-54

for 4 1/4 cables


332-202/66

N 5 external black tie, for the fixing of the cable running on the pole, are included in the installation kit (314-205/76),
provided with the external connection accessories (1+0).
Material to be adopted according to the installation requirements, is not included in the installation materials,
if required must be separately provided. Refer to PAR. 3.6.5.1 for the recommended spacing.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.7.6.1

Recommended clamp spacing for 1/4 coaxial cable


Clamp spacing recommendation is based on the guidelines stated in EIA Standard
RS-222 (Structural Standards for Steel Antenna Towers and Antenna Supporting
Structures) and BSI CP3 (Code of Basic Data for the Design of Buildings, Wind
Loading).
Geographical location, as well as height of tower/must, to which the clamps are
attached, may have a significant impact on installation conditions.
Therefore, unless otherwise specified, the assumptions made to define the maximum
clamp spacing are the following:

Tower height 45m

1/2lh radial ice

Clamps properly installed and tightened

Based on the above conditions, the recommended MAXIMUM CLAMP SPACING for
1/4 COAXIAL CABLE type LDF1RN-50 (Andrew) and CF 1/4lr CuH (RFS) is:
0.8m (Wind Load 200 Km/h) or 0.5m (Wind Load 240 Km/h).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-55

3 - INSTALLATION

3.7.7
Fig. 3.39

1/4 coaxial cable - Connection on IDU side


1/4 coaxial cable - Connection on IDU side
TO THE STATION
GROUNDING SYSTEM

IDU ASSEMBLY

1/4 coaxial cable


TO ODU
SECTION

Coaxial N-plug

Ground cable

OSM/N coaxial tail


(L.=1 Mt.)
(314-327/91)

TO 16xE1 BASE BAND UNIT

The figure shows a system in 1+1 or 2x(1+0) or ADD DROP configuration.


In case of 1+0 configuration only one IN/OUT connection is present.

3-56

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.7.8
Tab. 3.29

Andrew and RFS-Kabelmetal sets


Andrew set

P/N

Description

104-009/42
(314-327/79)*

1/4 LDF1RN - 50 ohm COAXIAL CABLE

597-523/94A
(597-523/94)*

1/4 COAX CABLE ACCESSORIES

LDF1RN-50

Unit

Q.ty

Mt.

NOTE
1

Nr.

L1PNM-HC

STRAIGHT N type COAX N-PLUG

421-008/88

L1PNR-HC

90 N type COAX N-PLUG

421-008/84

CSGL1-10B2

GROUNDING KIT

333-031/19

For the assembling instructions see doc. Connectors assembling.

Tab. 3.30

RFS-Kabelmetal set

P/N

Description

Unit

Q.ty

104-009/33
(314-327/79)*

1/4 CuH - 50 ohm COAXIAL CABLE

CF14-50JFN

Mt.

NOTE
1

597-523/94B
(597-523/94)*

1/4 COAX CABLE ACCESSORIES

597-523/94B

Nr.

15501035

STRAIGHT N type COAX N-PLUG

421-008/24

15501016

90 N type COAX N-PLUG

421-008/23

15509652

GROUNDING KIT

333-032/16

For the assembling instructions see doc. Connectors assembling.

The ANDREW and RFS-Kabelmetal material sets are alternative to each other.
Le quantit riportate si riferiscono ad una connessione singola IDU/ODU
NOTE 1 = The length of one IDU/ODU connection is 300 mt Max.
Commercial reference.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-57

3 - INSTALLATION

3.7.9
Tab. 3.31

Tab. 3.32

Characteristics
Construction characteristics

Diameter (mm)

2.6

2.4

Dielectric

Diameter (mm)

6.7

6.0

Outer Conductor

Diameter (mm)

7.7

7.5

Standard Jacket

Diameter (mm)

10.0

ANDREW

RFS-Kabel
metal

0.09

0.13

Mechanical characteristics

(kg/m)

Min. Bending Radius

single bend (mm)

38

40

Min. Bending Radius

repeated bends
(mm)

76

120

15 (30)

91

1.33

650

(kg/mm)

1.4

(m)

0.5

ANDREW

RFS-Kabel
metal

Recommended Temperature for


Installation

(C) - 25 / + 60

- 10 / + 60

Recommended Storage for


Installation

(C) - 30 / + 80

Operating Temperature

(C) - 30 / + 80

Number of Bends

Min. (tipico)

Tensile Strength

(kg)

Bending Moment

(N m)

Max. Tensile Force


Crash Strength
Max. Standard Hanger Spacing

3-58

RFS-Kabel
metal

Inner Conductor

Weight

Tab. 3.33

ANDREW

(N)

Range of temperature

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

Tab. 3.34

Electrical characteristics

Characteristics Impedance
Relative Propagation Velocity

ANDREW

RFS-Kabel
metal

(ohm)

50

50

(%)

87

82

Capacitance

(pF/m)

76.8

82

Maximun Operating Frequency

(MHz)

15800

3000

Cut-off Frequency

(MHz)

18700

Peak RF Voltage Rating

(kV)

1.1

0.83

Peak Power Rating

(kW)

12.1

6.9

DC Resistance : Inner Conductor

(ohm/km)

5.15

4.1

DC Resistance : Outer Conductor

(ohm/km)

3.33

3.5

(V)

2200

(H/m)

0.19

DC Breakdown
Inductance

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-59

3 - INSTALLATION

Tab. 3.35

3-60

Attenuation, (dB/100m) Standard conditions: VSWR 1.0 ; ambient temperature


24C
ANDREW

RFS-Kabelmetal

10 MHz

1.32

30 MHz

2.20

2.3

100 MHz

4.08

4.3

150 MHz

5.03

200 MHz

6.1

300 MHz

7.22

7.6

450 MHz

8.94

9.4

600 MHz

10.42

824 MHz

12.36

894 MHz

12.92

900 MHz

13.7

960 MHz

13.43

1000 MHz

13.73

1500 MHz

17.15

18.2

1700 MHz

18.38

1800 MHz

20.1

2000 MHz

20.13

2300 MHz

21.77

23.1

3000 MHz

27.0

4000 MHz

29.89

6000 MHz

37.94

10000 MHz

51.72

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

Tab. 3.36

Average Power Rating, kW Standard conditions : VSWR 1.0 ; ambient temperature


40C ; inner conductor temperature 100C ;

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

ANDREW

RFS-Kabelmetal

10 MHz

4.4

30 MHz

3.38

2.51

100 MHz

1.85

1.36

150 MHz

1.51

200 MHz

0.95

300 MHz

1.07

0.77

450 MHz

0.871

0.62

600 MHz

0.756

824 MHz

0.644

894 MHz

0.618

900 MHz

0.43

960 MHz

0.579

1000 MHz

0.585

1500 MHz

0.477

0.32

1700 MHz

0.448

1800 MHz

0.294

2000 MHz

0.413

2300 MHz

0.385

0.257

3000 MHz

0.221

4000 MHz

0.292

6000 MHz

0.239

10000 MHz

0.185

3-61

3 - INSTALLATION

3.8 IDU INSTALLATION


The IDU can be arranged for installation both on ETSI and 19" racks, by means of two
different types of brackets.
Before starting with the installation, IDU sub-rack has to be arranged for the rack type
(ETSI or 19") and then the identification plate has to be applied to the left bracket.
The IDU is delivered already assembled inserted.

3.8.1

Installation accessories
The Single Board IDU (P/N 732-101/71) is delivered with special fixing kit
(P/N 332-309/83).
In Tab. 3.37 the list and description is set down of the accessories contained in the fixing
kit.

Tab. 3.37

Fixing kit (P/N 332-309/83)


P/N

Q.ty

224-174/33

Brackets for 19" rack

224-174/32

Bracket for ETSI rack

TC M48 screw

3x6 screw

204-364/07D
201-401/06

3-62

Denomination

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.8.2

Single Board IDU sub-rack arrangement for ETSI rack

Fig. 3.40

In the sub-rack front part (3), install on the side panels, the two brackets (1) for
ETSI rack, by means of the relevant two fixing screws (2).

Single Board IDU sub-rack arrangement for ETSI rack

(3)

Flat head
screw
3x6
(2)
(201-401/06D)

Cylindrical head
screw 3x6
(2)
(201-401/06D)

(1) Bracket for ETSI


(224-174/32)

Bracket for ETSI (1)


(224-174/32)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-63

3 - INSTALLATION

3.8.3

Single Board IDU sub-rack arrangement for 19 rack

Fig. 3.41

In the sub-rack front part (3), install on the side panels, the two brackets (1) for
ETSI rack, by means of the relevant two fixing screws (2).

Single Board IDU sub-rack arrangement for 19 rack

(3)

Flat head
screw
3x6
(2)
(201-401/06D)

(1)

Cylindrical head
screw 3x6
(2)
(201-401/06D)

Bracket for 19
(224-174/33)

Bracket for 19
(1)
(224-174/33)

3-64

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.8.4

Fig. 3.42

Single Board IDU sub-rack installation in the rack

Insert the IDU (1) in the relevant housing of the rack.

Screw down the four screws (2) fixing the IDU (1).

Fix the support of the coaxial cables (3) to the frame, screwing the two relevant
fixing screws (4).

Single Board IDU sub-rack installation in the rack

IDU subrack
1
2

1 - Single Board IDU


2 - Screw
3 - Coaxial fixing cable bracket (to be used with 1/4 IDU/ODU cable only)
4 - Screw

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-65

3 - INSTALLATION

3.8.4.1

Single Board IDU grounding connections

Fig. 3.43

Single Board IDU grounding connections

TO THE STATION
GROUNDING SYSTEM

(*)

Grounding cable
YE-GR PVC 1x25 mm2

Grounding cable
(6 mm2 L = 400)
(314-303/56)

IDU subrack

(**)

Grounding bar

M4x8 cylindrical head screw

(***)

* = This cable is included in the 19 (ETSI) rack


** = This cable is included in the external connection accessories (597-525/16)
*** = These accessories are supplied with the wired subrack

3-66

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.9 EXTERNAL CONNECTIONS


All the connectors used for the external connections are easily accessible from the front
side of the indoor assembly.
All the cables from/to the outside are brought down from the cabinet top inside the side
wall slots or, in the case the wiring is running under the raised floor, they are made to
ascend likewise.

3.9.1

Primary supply voltage connection


The outdoor assembly (ODU) is remotely power supplied by the indoor IDU
(P/N 732-101/71) by means of 1 coaxial connection cable (2 in the 1+1 configuration).
The indoor assembly is fed by DC/DC converters, which transform the delivered -48 V
voltage.
The primary supply voltage, delivered by 48 V battery, has to be applied to the 3-poles
male connector MAIN POWER INPUT. See Fig. 3.44.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-67

3 - INSTALLATION

Fig. 3.44

Primary Power Supply Connections

INDOOR ASSEMBLY (SINGLE BOARD)

PS

A3

Female connector
(422-060/61)

(*)

Female contact
(422-027/31)

(*)

A1

CRIMPING
SIDE VIEW

A1 = Positive
A3 = Negative

MAXIMUM POWER
CONSUMPTION
1+0 = 50 W
1+1 = 90 W

3-68

Metal shell
(422-030/821)

Nominal voltage
-48 Vdc + 20%
(-38.4 to 57.6 Vdc)

(*)

2x1.5 mm2 bipolar shielded


cable for power supply

STATION
Main negative
power supply

PS (pin A3)
STOTZ
4A

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

3.9.2

Connector functions
Fig. 3.46 to Fig. 3.55 and Tab. 3.38 to Tab. 3.39 show the positions and functions of the
connectors.

Fig. 3.45

ODU connections (SMA coax. connector)

ODU 2

ODU 1

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-69

3 - INSTALLATION

Fig. 3.46

2 Mbit/s 120 ohm (SUB-D) from 1 to 8 Tributary Connections


INDOOR ASSEMBLY (SINGLE BOARD)

2 Mbit/s I/O Tributaries 1-8

34

Tx DATA Wire b
18
2

Tx DATA Wire a
35

37

38
22

23

25

(a)(b)(c)

26

27

28

29

30
14
31

*Rx DATA Wire b

Channel no. 1

*Tx DATA Wire b


*Rx DATA Wire b

Channel no. 4

Rx DATA Wire a
48

32

*Tx DATA Wire b


Tx DATA Wire a

49

16

Channel no. 2

*Tx DATA Wire b

Tx DATA Wire a
47

15

*Rx DATA Wire b

Rx DATA Wire a
46

13

*Tx DATA Wire b

Tx DATA Wire a
45

12

Channel no. 7

Rx DATA Wire a
44

11

*Rx DATA Wire b

Tx DATA Wire a
43

10

*Tx DATA Wire b

Rx DATA Wire a
42

Channel no. 8

Tx DATA Wire a
41

*Rx DATA Wire b


Rx DATA Wire a

40
24

Tributary cable
8xE1 120 ohm
(L=5/10/20/30 m)
(314-331/79..82)

Channel no. 5

*Tx DATA Wire b


Tx DATA Wire a

39

Rx DATA Wire b
Rx DATA Wire a

21

Tx DATA Wire b
Tx DATA Wire a

20

Channel no. 6

Rx DATA Wire a
36

Rx DATA Wire b

19

Channel no. 3

Rx DATA Wire b
33
17

Rx DATA Wire a
50

(a) = This prewiring cable is a standard solution; on request is possible to order the
single materials and to make the cable in field.
(b) = This material is supplied with the installation materials.
(c) = The lenght for this cable is 200 m max.

3-70

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

Fig. 3.47

2 Mbit/s 120 ohm (SUB-D) from 9 to 16 Tributary Connections

INDOOR ASSEMBLY (SINGLE BOARD)

2 Mbit/s I/O Tributaries 9-16

34

Tx DATA Wire b
18

Tx DATA Wire a
35

37

38
22

23

25

26

27

28
12
29

30

31

*Rx DATA Wire b

Channel no. 9

*Tx DATA Wire b


*Rx DATA Wire b

Channel no. 12

Rx DATA Wire a
48

32

*Tx DATA Wire b


Tx DATA Wire a

49

16

Channel no. 10

*Tx DATA Wire b

Tx DATA Wire a
47

15

*Rx DATA Wire b

Rx DATA Wire a
46

14

*Tx DATA Wire b

Tx DATA Wire a
45

13

Channel no. 15

Rx DATA Wire a
44

11

*Rx DATA Wire b

Tx DATA Wire a
43

10

*Tx DATA Wire b

Rx DATA Wire a
42

Channel no. 16

Tx DATA Wire a
41

*Rx DATA Wire b


Rx DATA Wire a

40
24

Tributary cable
8xE1 120 ohm
(L=5/10/20/30 m)
(a)(b)(c)
(314-331/79..82)

Channel no. 13

*Tx DATA Wire b


Tx DATA Wire a

39

Rx DATA Wire b
Rx DATA Wire a

21

Tx DATA Wire b
Tx DATA Wire a

20

Channel no. 14

Rx DATA Wire a
36

Rx DATA Wire b

19

Channel no. 11

Rx DATA Wire b
33
17

Rx DATA Wire a
50

(a) = This prewiring cable is a standard solution; on request is possible to order the
single materials and to make the cable in field.
(b) = This material is supplied with the installation materials.
(c) = The lenght for this cable is 200 m max.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-71

3 - INSTALLATION

Fig. 3.48

2 Mbit/s 75 ohm (SUB-D) from 1 to 8 Tributary Connections

INDOOR ASSEMBLY (SINGLE BOARD)

2 Mbit/s I/O Tributaries 1-8


1

34

Tx DATA

18

Rx DATA

19
36

3
20

Tx DATA

Rx DATA

21
38

5
22
6

Tx DATA
Channel no. 8

39

Rx DATA

23
7

40
24

Tx DATA
Channel no. 7

41

Rx DATA

25
9

42

Tx DATA

26
10

Channel no. 2

43

Rx DATA

27
44

11
28

Tx DATA
Channel no. 1

45

12

Rx DATA

29
46

13
30
14

Tx DATA
Channel no. 4

47

Rx DATA

31
48

15
32

Tx DATA
Chanell no. 3

49

16

Rx DATA

33
17

Channel no. 5

37

(a)(b)(c)

Channel no. 6

35

Tributary cable
8xE1 75 ohm
(L=5/10/20/30 m)
(314-331/35..38)

Rx-GND (to be connected


to shell cable-clamp)

50

(a) = This prewiring cable is a standard solution; on request is possible to order the
single materials and to make the cable in field.
(b) = This material is supplied with the installation materials.
(c) = The lenght for this cable is 300 m max.

3-72

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

Fig. 3.49

2 Mbit/s 75 ohm (SUB-D) from 9 to 16 Tributary Connections

INDOOR ASSEMBLY (SINGLE BOARD)

2 Mbit/s I/O Tributaries 9-16

34

Tx DATA

18

Rx DATA

19
36

Tx DATA

20
4

Channel no. 13

37

Rx DATA

21
5

38

Tx DATA

22
6

Channel no. 16

39

Rx DATA

23
7

40

Tx DATA

24
8

Channel no. 15

41

Rx DATA

25
42

Tx DATA

26

Channel no. 10

43

10

Rx DATA

27
11

44

Tx DATA

28
12

Channel no. 9

45

Rx DATA

29
13

46

Tx DATA

30
14

Channel no. 12

47

Rx DATA

31
15

48

Tx DATA

32
16

Channel no. 11

49

Rx DATA

33
17

Channel no. 14

35

Tributary cable
8xE1 120 ohm
(L=5/10/20/30 m) (a)(b)(c)
(314-331/79..82)

Rx-GND (to be connected


to shell cable-clamp)

50

(a) = This prewiring cable is a standard solution; on request is possible to order the
single materials and to make the cable in field.
(b) = This material is supplied with the installation materials.
(c) = The lenght for this cable is 300 m max.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-73

3 - INSTALLATION

Fig. 3.50

Alarm connections

INDOOR ASSEMBLY (SINGLE BOARD)

ALMs

ALIM OFF
9

IDU
10

15 C male
SUB-D connector
(422-062/86)

(*)

CRITICAL
11

ODU
MAJOR

12
5
13
6
14
7
15
8

Metal shell
(422-030/92)

CEN-IN2
CEN-IN1
CEN-IN4
CEN-IN3

(*)

8-pair double
shield cable

(*) Materials included in the alarm accessories kit P/N 332-055/49A.

3-74

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

Tab. 3.38

Alarm meaning
Pin

Alarm

ALIM OFF

Not used

IDU

IDU alarm

10

Not used

CRITICAL

11

ODU

MAJOR

12

Not used

Not used

13

Not used

Not used

14

CEN-IN2

Station alarm input #2 (to remote station)

CEN-IN1

Station alarm input #1 (to remote station)

15

CEN-IN4

Station alarm input #4 (to remote station)

CEN-IN3

Station alarm input #3 (to remote station)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

Description
No power supply alarm

Critical alarm
ODU alarm
Major alarm

3-75

3 - INSTALLATION

Fig. 3.51

64 kbit/s (V.11) service channel connnection: USER/Dext (USER 1)


INDOOR ASSEMBLY (SINGLE BOARD)

USER/Dext

For the pin function see Fig. 3.52.

9 C male
SUB-D connector
(422-062/60)

(*)

Tx DATA Wire b

2
7

8
4
9

Metal shell
(422-030/91)

Rx DATA Wire a
Rx DATA Wire b

Tx DATA Wire a

Rx CLOCK Wire a
Rx CLOCK Wire b
Tx CLOCK Wire a
Tx CLOCK Wire b
GND

(*)

8-pair double
shield cable

(*) These accessories are included in the installation kit P/N 332-055/29A.

3-76

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

Fig. 3.52

64 kbit/s (V11) service channel connnection


USER (a)
CO-DIRECTIONAL
CLOCK (a)
1

DATA Tx

Wire a

DATA Tx

Wire b

DATA Rx

Wire a

DATA Rx

Wire b

CONTRA-DIRECTIONAL
CLOCK (a)

6
2
7
3
CLOCK Rx Wire a
8
CLOCK Rx Wire b
4

CLOCK Tx Wire a
9
CLOCK Tx Wire b

5
GND

Dext (a)
CONTRA-DIRECTIONAL
Dext (a)
1

DATA Rx

Wire a

DATA Rx

Wire b

DATA Tx

Wire a

DATA Tx

Wire b

Dext SRA L
compatible (a)

6
2
7
3
CLOCK Tx Wire a
8
CLOCK Tx Wire b
4

CLOCK Rx Wire a
9
CLOCK Rx Wire b

5
GND
WIRING CABLE for
CONNECTION BETWEEN CHANNELS
Dext-Dext SRA L compatible
2
7
1
6
3
8
4
9

1
6
2
7
3
8
4
9

a) Configuration of User (Co/Contra-directional Clock) or Dext/Dext SRA L compatible


channels is a software controlled operation.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3-77

3 - INSTALLATION

Fig. 3.53

Supervision connections (Q LAN - V LAN)


INDOOR ASSEMBLY (SINGLE BOARD)
Tx1

Tx5

Tx9

Tx13

Rx1

Rx5

Rx9

Rx13

Q-LAN
ALMs

USER/Dext

ODU CABLE

s
I

USER/Dext

SRAL XD

C
H
A

C
H
B

C
B
L

O
D
U

'

H
A

H
B

B
L

D
U

'

PS

CAUTION
Vbattery

V-LAN
LCT

'

T
E
S
T

M
N
/
W

C
/
M
J

ODU CABLE

PS

CAUTION
Vbattery

Q-LAN

V-LAN

QLAN

VLAN

(10/100 BASE T)

Fig. 3.54

(10 BASE T)

DATA Tx Wire b

DATA Tx Wire a

DATA Rx Wire b

NOT USED

NOT USED

DATA Rx Wire a

NOT USED

NOT USED

Connection example (Q LAN - V LAN)

EXAMPLE A

10

11

EXAMPLE B

SRAL XD-1

10

SRAL XD-1

To LAN X

A
10

11

11

SRAL XD-2

10

11

SRAL XD-2

HUB

To LAN Y

B
10

11

SRAL XD-n

10

11

SRAL XD-n

To LAN Z

To LAN

B
LEGENDA: 10 = Q LAN;

3-78

11 = V LAN

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

3 - INSTALLATION

Fig. 3.55

LCT connection (RS 232)


INDOOR ASSEMBLY (SINGLE BOARD)

Tx1

Tx5

Tx9

Tx13

Rx1

Rx5

Rx9

Rx13

ODU CABLE

SRAL XD

Q-LAN
ALMs

USER/Dext

USER/Dext

LCT

C
H
A

C
H
B

C
B
L

O
D
U

'

H
A

H
B

B
L

D
U

'

PS

CAUTION
Vbattery

V-LAN

'

T
E
S
T

M
N
/
W

C
/
M
J

ODU CABLE

PS
CAUTION
Vbattery

LCT

9 C male
SUB-D connector

NAL
PERSO
UTER
COMP

The LCT connector (F interface) can be used also to connect a SRAL XD to extend
a SRAL network as shown in Fig. 3.56.
Tab. 3.39

LCT connector (RS 232)


Pin

Signal

I/O

Description

F_CD

Received Line Signal Detector (Data Carrier Detect)

F_RxD

Received Data

F_TxD

Transmit Data

F_DTR

Data Terminal Ready

GND

F_DSR

Data Set Ready

F_RTS

Request To Send

F_CTS

Clear To Send

n.c.

Ring Indicator

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

Signal Ground

3-79

3 - INSTALLATION

Fig. 3.56

Example of the F interface used to extend a SRAL network

V bus

V
SRAL

V
SRAL

SRAL
F

LCT
F
SRAL XD

3-80

F
SRAL XD

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

4 - ACTIVATION

4 ACTIVATION
4.1 PRESETTINGS
In this paragraph instructions are given to check and, if required, to carry out the
presettings relevant to the system type where the equipment is utilized.
There are two presetting types:

4.1.1

Hardware settings, performed through jumpers or connections

Software settings, carried out through PC with dedicated software. With regard to
the system software setting options refer to the Guide to the use of the control
software", in the Operator Manual (OMN).

Hardware settings
In the equipment there are no hardware settings.

4.1.2

System E2PROM
The IDU contains two different system EEPROMs to store all the NE configurations:

internal EEPROM installed in the Mother Board in the Controller section.

external EEPROM (KEY), inserted in the IDU front panel.

In the key in the factory have been stored the Serial Number (S/N) and the licence type.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

4-1

4 - ACTIVATION

4.2 ACTIVATION
This paragraph includes the procedures for checkings that can be carried out during the
installation while activating the equipment.
Fig. 6.10 shows the connectors and the control elements, located on the equipment
front panel.

4.2.1

Local checks
The equipment is tested and adjusted at the factory in order to optimize the
characteristics: usually, checks are not required while installed.
Therefore, the procedures here below described have to be utilized only in case of
problems arising in the system, due to equipment malfunction.
The checks are:

4.2.2

make sure the equipment is correctly equipped as per indications in the par. 2.3
"EQUIPMENT COMPOSITION".

check the connection cables (or cable) between the indoor assembly and the
outdoor assemblies (or assembly) are connected and IDU/ODU connection have
been made as per indications in the par. 3.6 "IDU/ODU CONNECTION WITH
BRAIDED COAXIAL CABLE" or par. 3.7 "IDU/ODU CONNECTION WITH 1/4
COAXIAL CABLE".

check the equipment is connected to the primary supply voltage as described in the
par. 3.9.1 "Primary supply voltage connection".

IDU first installation

Insert the KEY into the connector on the front panel.

Switch ON the IDU by turning the ON/OFF switch.

At this point the Controller reads the S/N and the type of license of the KEY and
stores it internally.

The LCT shall now be able to complete the equipment configuration. (Based on the
type of license memorised a basic default configuration will be memorised on the
KEY).

When configuring the equipment through the LCT, the configuration will be
automatically memorised both on the Controller and on the KEY.

The KEY must always be inserted during regular equipment configuration. Should
it be removed, the "Memory key disconnected" alarm will be activated.
If a KEY other than that used during the first installation is inserted while the
equipment is ON, the Controller compares the S/N and the type of license
memorised (and that corresponds to the first installation KEY) with that of the
KEY inserted. A data misalignment is detected and the "No setting mode" alarm
is detected which will prevent modifying the configuration through the LCT.

4-2

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

4 - ACTIVATION

The following are the alarms associated to the KEY:


Tab. 4.1

KEY alarms
Alarm

Fig. 4.1

Description

LCT alarm

Key missing

Physically missing

Memory key disconnected


alarm activated

Key Fault

Non recoverable data


failure

Key fault alarm activated

Key Mismatch

Data memorised on the


key differ from those
memorised on the IDU

No setting mode alarm


activated

IDU Key position

IDU ASSEMBLY (SINGLE BOARD)

KEY

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

4-3

4 - ACTIVATION

4.2.3

Alignment
It is necessary to execute the alignment of the antenna to ensure the correct
operation of the equipment and to make reliable the radio link to the remote
terminal.
For the procedures of adjustment and aiming of the antenna, refer to the
documentation annexed to the antenna themselves.
To make easy the aiming operation, the ODU is equipped with a BNC connector that
makes available the AGC voltage as function of the received field.

Fig. 4.2

ODU connection for the measurement of the received field (Rx field)

BNC connector for


Rx field measure

The VAGC range is between -3.4 V and 1.2 V (typical values) for PRX values
between -30 dBm and -75 dBm, according to a linear law with rate of about 0.5 V
for 10 dB.

4-4

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

4 - ACTIVATION

4.2.4

Local checks on the equipment

4.2.4.1

Control of the system configuration


Control, by means of the supplied SW (LCT), that the system configuration is according
to what required for the connection in object. In particular, it is necessary to set on both
terminals the configuration (see par. 2.3.1 "System configurations"), the operating
frequency and the ATPC enabling, according to what foreseen by the specifications
related to the interested link.
Eventually, configure the equipment according to what specified in Guide to use of the
control software, in the Operator Manual (OMN).

4.2.4.2

Configuration of IP address
On the first installation, the IDU has a default IP address (192.168.255.3) and then the
user can access the NE, set the network IP address and build the map containing the
IP saddress itself. For this purpose, refer to the guide to use of the management
program, of the OMN manual.
If the network planning was not available, it is necessary to insert, in the two terminals,
addresses belonging to two different IP subnetwork (for example: site A =
100.100.100.6; site B = 150.150.150.6), Netmask 255.255.255.0, to be able to control
both the Network Elements

4.2.5
4.2.5.1

Link checks
Final checks
After all the local checks and the alignment operation have been executed, check that
the levels of the received power in both the terminals are in compliance to the project
specification.

4.2.5.2

Switching test
In presence of protected configurations (1+1 Frequency Diversity or 1+1 Hot Standby),
proceed to the check of the switching functionality.
Wit the aid of a PDH (2 Mbit/s) frame analyzer, connected to the tributary access points,
check that, after the different switching operations, the service stays active.
For a correct execution of the switching operations, refer to the guide of use of
the management program, in OMN manual.

4.2.5.3

Restore of the operating conditions


Once the checks on the connection have been executed, restore the operating
conditions of the system (removing the possible manual forcing).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

4-5

4 - ACTIVATION

4.3 NORMAL OPERATING CONDITIONS AND


ALARMS
4.3.1

Normal operating conditions


Normal operating conditions of the equipment are indicated as follows:

power supply switch in position I (ON);

all the red LEDs on the front panel of the IDU must be OFF;

RF output power and RF input power at nominal values.

The normal operating conditions of the front panel LEDs are shown in Fig. 4.3.

4.3.2

Alarm conditions
An alarm condition indicates a failure in the outdoor or indoor unit.
An alarm condition in the equipment is indicated by the switching on of a red LED on the
front panel of the IDU sub-rack.
The alarms are also processed and managed by the Controller. The LCT, connected
to the Controller, allows an easy location of the failed unit.

Fig. 4.3

LEDs status in the normal operating conditions

IDU ASSEMBLY (SINGLE BOARD)

see
Tab. 6.2

I
POSITION
OFF

4-6

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

5 - MAINTENANCE

5 MAINTENANCE
5.1 TROUBLESHOOTING AND RESTORING
This paragraph instructs about troubleshooting to be carried out on the equipment.
The malfunctions are pointed out by LEDs on the equipment, on the indoor assembly
front panel (see Fig. 5.1).
The indications function on the front panel is described in the par. 6.5 "LED,
MONITORING POINTS, CONNECTORS AND SWITCHES".
The sequence of the recommended actions to locate a faulty part of the equipment, to
replace it and to restore the service, are schematized in Fig. 5.2.

5.1.1

Troubleshooting
The failed unit is located by using the LCT: refer to the document "Guide to the use of
the control software", which is part of the Operator Manual (OMN).

Fig. 5.1

LEDs

IDU ASSEMBLY (SINGLE BOARD)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

5-1

5 - MAINTENANCE

5.1.2

Replacement procedures in 1+0 systems


This paragraph contains the instruction to carry out the system parts fault replacement.
Follow the instructions step by step, otherwise the SW configuration could be lost, and
therefore the LCT is necessary for a new SW configuration setting.
Note: The IDU front panel LEDs give fault status general information; in case of a more
deep investigation about cause and severity one alarm is requested, the LCT is
necessary.

5.1.2.1

5.1.2.2

5.1.2.3

5-2

ODU replacement
1.

Disconnect the IDU/ODU cable (ODU side).

2.

Replace the ODU and connect again the IDU/ODU cable.

3.

Verify that the link has been recovered (no alarm)

IDU-ODU cable replacement


1.

Disconnect the faulty IDU-ODU connection cable.

2.

Connect a new IDU-ODU cable.

3.

Verifies that the LEDs are in the normal operating conditions.

4.

Otherwise, see Troubleshooting through LCT (OMN manual).

IDU (Single Board) replacement


1.

Switch off the IDU (ON/OFF switch on the right side in position O).

2.

Disconnect all the cables connected on the IDU front panel and the memory key.

3.

Replace the IDU with the spare IDU.

4.

Connect again all the cables on the IDU front panel and the memory key.

5.

Switch on the IDU (ON/OFF switch on the right side in position I). The equipment
configuration, that has been saved on the key, will be automatically stored in the
new IDU.

6.

Verify the restoring of the normal conditions in the link (no alarm).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

5 - MAINTENANCE

5.1.3

Unit replacement procedures in 1+1 systems


This paragraph contains the instruction to carry out the system parts fault replacement.
Follow the instructions step by step, otherwise the SW configuration could be lost, and
therefore the LCT is necessary for a new SW configuration setting.
Note: The IDU front panel LEDs give fault status general information; in case of a more
deep investigation about cause and severity one alarm is requested, the LCT is
necessary.

5.1.3.1

5.1.3.2

5.1.3.3

ODU replacement
1.

Force ON LINE the other channel.

2.

Perform by LCT the power down command in the ODU to be replaced.

3.

Disconnect the IDU/ODU cable (ODU side).

4.

Replace the ODU and connect again the IDU/ODU cable.

5.

Perform by LCT the power up command in the replaced ODU.

6.

Wait until all alarms disappear from alarm list.

7.

Wait at least 30 seconds before removing all forcing via LCT commands.

8.

Verify that the link has been recovered (no alarms).

IDU-ODU cable replacement


1.

Force ON LINE the other channel.

2.

Perform by LCT the power down command in the relevant ODU.

3.

Disconnect the fault IDU-ODU.

4.

Connect a new IDU-ODU cable.

5.

Perform by LCT the power up command in the relevant ODU.

6.

Wait until all alarms disappear from alarm list.

7.

Wait at least 30 seconds before removing all forcing via LCT commands.

8.

Verify that the link has been recovered (no alarms).

IDU (Single Board) replacement


1.

Switch off the IDU (ON/OFF switch on the right side in position O).

2.

Disconnect all the cables connected on the IDU front panel and the memory key.

3.

Replace the IDU with the spare IDU.

4.

Connect again all the cables on the IDU front panel and the memory key.

5.

Switch on the IDU (ON/OFF switch on the right side in position I). The equipment
configuration, that has been saved on the key, will be automatically stored in the
new IDU.

6.

Verify the restoring of the normal conditions in the link (no alarm).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

5-3

5 - MAINTENANCE

5.1.4

Configuration change
The configuration change described in this paragraph refers to the change of the
capacity or frequency in 1+1 systems.

5-4

1.

Force ON LINE the channel at the remote station.

2.

Force ON LINE the channel at the local station.

3.

Change the capacity (or the frequency) on the ODU not ON LINE at the remote
station.

4.

Change the capacity (or the frequency) on the ODU not ON LINE at the local
station

5.

Force ON LINE the other channel at the remote station.

6.

Force ON LINE the other channel at the local station.

7.

Perform the same capacity (or frequency) change in the ODU not ON LINE at the
remote station.

8.

Perform the same capacity (or frequency change) in the ODU not ON LINE at the
local station.

9.

Remove all forcing via LCT commands.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

5 - MAINTENANCE

Fig. 5.2

Flow chart No. 1 - Intervention procedure because of failure


IN STATION

MAINTENANCE CENTER

1a PHASE

START

THROUGH THE PC
LOCATE THE FAULTY
UNIT (IDU or ODU)

COLLECT THE SPARE


UNIT TO BE SENT
TO THE STATION
REPLACE THE FAULTY UNIT
WITH THE SPARE ONE.
BY THE PC, CHECK THE
NORMAL OPERATING
CONDITIONS ARE RESTORED
(UNIT STATUS = NORMAL)

STOP

2a PHASE

START
SEND THE FAULTY UNIT TO
THE MAINTENANCE CENTER
SEND THE FAULTY UNIT TO
FACTORY FOR REPAIR

STOP

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

5-5

5 - MAINTENANCE

5.2 LIST OF SPARE PARTS


The maintenance philosophy consists in the replacement of an outdoor assembly (ODU)
of the IDU. Therefore all spares consist of outdoor od indoor assembly and units that
have the same P/N of the failed ones.

5.2.1
Tab. 5.1

Single Board IDU spare parts list


List of spare parts - Single Board IDU
Denomination

5.2.2

P/N

IDU Single Board 1+0 8xE1 SUB-D 120/75 ohm

732-101/71A

IDU Single Board 1+0 16xE1 SUB-D 120/75 ohm

732-101/71C

IDU Single Board 1+1 8xE1 SUB-D 120/75 ohm

732-101/71G

IDU Single Board 1+1 16xE1 SUB-D 120/75 ohm

732-101/71E

ODU spare parts list


Each ODU has been adjusted in factory to a frequency of an RF channel. The list of the
available ODUs is given in table from Tab. 5.2 to Tab. 5.18.

Tab. 5.2

Tab. 5.3

Tab. 5.4

Tab. 5.5

5-6

ODU HD/HP 7 GHz


ODU P/N

ODU composition

732-241/07-xxx

See par. 2.3.15.1

ODU HD/HP 8 GHz


ODU P/N

ODU composition

732-241/08-xxx

See par. 2.3.15.2

ODU HD/HP 15 GHz


ODU P/N

ODU composition

732-241/15-xxx

See par. 2.3.15.3

ODU HD/HP 18 GHz


ODU P/N

ODU composition

732-241/18-xxx

See par. 2.3.15.4

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

5 - MAINTENANCE

Tab. 5.6

Tab. 5.7

Tab. 5.8

Tab. 5.9

Tab. 5.10

Tab. 5.11

Tab. 5.12

Tab. 5.13

ODU HD/HP 23 GHz


ODU P/N

ODU composition

732-241/23-xxx

See par. 2.3.15.5

ODU HD/HP 26 GHz


ODU P/N

ODU composition

732-241/26-xxx

See par. 2.3.15.6

ODU HD/HP 28 GHz


ODU P/N

ODU composition

732-241/28-xxx

See par. 2.3.15.7

ODU HD/HP 38 GHz


ODU P/N

ODU composition

732-241/38-xxx

See par. 2.3.15.8

ODU ND 7 GHz
ODU P/N

ODU composition

732-251/07-xxx

See par. 2.3.15.9

ODU ND 8 GHz
ODU P/N

ODU composition

732-251/08-xxx

See par. 2.3.15.10

ODU ND 13 GHz
ODU P/N

ODU composition

732-251/13-xxx

See par. 2.3.15.11

ODU ND 15 GHz
ODU P/N

ODU composition

732-251/15-xxx

See par. 2.3.15.12

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

5-7

5 - MAINTENANCE

Tab. 5.14

Tab. 5.15

Tab. 5.16

Tab. 5.17

Tab. 5.18

5-8

ODU ND 18 GHz
ODU P/N

ODU composition

732-251/18-xxx

See par. 2.3.15.13

ODU ND 23 GHz
ODU P/N

ODU composition

732-251/23-xxx

See par. 2.3.15.14

ODU ND 26 GHz
ODU P/N

ODU composition

732-251/26-xxx

See par. 2.3.15.15

ODU ND 28 GHz
ODU P/N

ODU composition

732-251/28-xxx

See par. 2.3.15.16

ODU ND 38 GHz
ODU P/N

ODU composition

732-251/38-xxx

See par. 2.3.15.17

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

5 - MAINTENANCE

5.3 PROCEDURE FOR SPARE PARTS USE


This paragraph illustrates the procedure to use when having to replace the faulty IDU
and the faulty ODU.
To simplify the description, the following procedures concern the disassembling of the
parts to replace. Obviously to place the spare part back proceed in the opposite manner.

5.3.1

Procedure for the IDU replacement


The replacement of the IDU subrack can be carried out in the following manner:

5.3.2

a)

Switch off the unit by the power supply switch on the front panel.

b)

Disconnect the cables present on the IDU front panel.

c)

Unscrew the screws present on the IDU front panel.

d)

Remove the IDU.

Procedure for the ODU replacement


To replace the ODU remove the ODU from the supporting framework fastened to the
mast.
The procedure to follow is specified below:
a)

Pull out the IF cable.

b)

Disconnect the ground.

c)

Disconnect the RF waveguide.

d)

Remove the ODU from the supporting frame.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

5-9

LA

PA
G
E

5 - MAINTENANCE

5-10

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

6 - FUNCTIONAL DESCRIPTION

6 FUNCTIONAL DESCRIPTION
6.1 IDU ARCHITECTURE
Fig. 6.1 and Fig. 6.2 report the block diagram of the IDU in 1+0 configuration.
The basic version (1+0) of the IDU consists of the following sections:

8xE1 or 16xE1 section (75 Ohm unbal. or 120 Ohm bal.), that represents the
physical access of the equipment for the 2 Mbit/s (E1) Tributary streams of the
public network

Controller section that includes all the control and supervisory functions.

BB, Adapter, LIU and Cable Interface section, that includes all the base band
processing, cable protection and IDU-ODU auxiliary service channel management

The 8xE1 and 16xE1 section also includes all the alarm and remote commands
interfacing to/from the remote terminal.
The configuration of the IDU, (1+1 H/S) is obtained by duplicating only the LIU and Cable
Interface.
The IDU is provided with an EEPROM memory fitted on the Controller section and of a
KEY to insert onto the front panel containing all the configuration parameters.

6.1.1

2 Mbit/s (8xE1 or 16xE1) Tributary section


This section carries out the following functions:

impedance matching of the 2 Mbit/s I/O tributaries

input tributary branching towards the BB section.

The section also consists of all the circuitry required to perform the service channel
(USER/Dext) interface and to perform the switching functions. The 2 channels are in
alternative and are software programmed and managed by the BB section (USER) and
by the Controller section (Dext).

Management of the system alarms and of the remote control signals

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

6-1

6 - FUNCTIONAL DESCRIPTION

6.1.2

BB, Adapter, LIU and Cable Interface section


This section carries out the following functions:

regenerate the 2 Mbit/s input tributary signals in compliance with Rec. G.703 and
HDB3 -> NRZ convert the associated code

monitor the incoming 2 Mbit/s streams

generation of the aggregate frame and multiplexing of the input tributary signals
into one 51.84 Mbit/s stream

scrambler and aggregate signal encoding

generation of a 128 kbit/s auxiliary service channel for the transmission of data
channels, alarms etc., between the IDU and the ODU that will be inserted into the
51.84 Mbit/s stream

transmission/reception in full duplex mode of the 51.84 Mbit/s stream on the


coaxial cable. (This function is performed by the LIU block)

generation of the switching command for the Tx switch should the equipment be
set to the protected configuration.

automatic level control on the signal incoming from the ODU.

The section also comprises of:

all the circuitry necessary to carry out the Rx switching function between the two
aggregate signals when the equipment has been set to the protected configuration.

all the circuitry necessary to realise the "Line driver" function in order to send and
receive the following signals from the ODU via only 1 coaxial cable:

51.84 Mbit/s stream

power supply voltage for the ODU

The section also contains the DC/DC converters to supply all the sections.

6.1.3

Controller section
The Controller section implements a system controller, that is capable of managing all
the system configurations. The main functions are:

6-2

collection of alarms and working parameters from the system units (IDU and ODU);
transmission of this information to a local PC and to a network supervision system

activation of system commands coming from a local PC or from a network


supervision system (status forcing, modification of equipment parameters, etc.)

storage on a Memory key of the system configurations and on EEPROMs the


inventory / user data and alarms history.

routing of messages among controllers and the network supervision system


manager

electrical and protocol translation between the radio environment (which uses a
proprietary protocol channel, embedded in the radio frame, to transport
management information) and the supervision system (which requests that this
information is available on a public connector, with a standard protocol).

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

6 - FUNCTIONAL DESCRIPTION

Fig. 6.1

SRAL XD: 8xE1 (1+0) configuration


USER
ALARM
CHANNEL
INT.

ODU
Rx

IDU Single Board


DEM
Cable
INT.

Tx

MOD

LIU
SECT. ADAPTER
SECT.
and
CABLE
INT.

BB
SECT.

TRIB.
8xE1
BASE
SECT.

TRIB.
2 Mbit/s (E1)

STATION
BATTERY

F INT.

CONTROLLER
SECT.

V INT.

Fig. 6.2

Q INT.

SRAL XD: 16xE1 (1+0) configuration

USER
ALARM
CHANNEL
INT.

ODU
Rx

IDU Single Board


DEM
Cable
INT.

Tx

MOD

LIU
SECT. ADAPTER
and
SECT.
CABLE
INT.

BB
SECT.

CONTROLLER
SECT.

TRIB.
8xE1
BASE
SECT.

TRIB.
2 Mbit/s (E1)

TRIB.
8xE1
EXP
SECT.

TRIB.
2 Mbit/s (E1)

F INT.

STATION
BATTERY

V INT.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

Q INT.

6-3

6 - FUNCTIONAL DESCRIPTION

Fig. 6.3

SRAL XD: 8xE1 (1+1) H/S with one antenna configuration


USER
ALARM
CHANNEL
INT.

ODU 1
Rx

IDU Single Board

DEM
Cable
INT.

Tx

MOD

LIU
SECT.
and
CABLE
INT.

ADAPTER
SECT.

TRIB.
8xE1
BASE
SECT.

BB
SECT.

TRIB.
2 Mbit/s (E1)

STATION
BATTERY

F INT.

CONTROLLER
SECT.

ODU 2
Rx

DEM
Cable
INT.

Tx

MOD

LIU
SECT.
and
CABLE
INT.

V INT.

Fig. 6.4

Q INT.

SRAL XD: 16xE1 (1+1) H/S with one antenna configuration


USER
ALARM
CHANNEL
INT.

ODU 1
Rx

IDU Single Board

DEM
Cable
INT.

Tx

MOD

LIU
SECT.
and
CABLE
INT.

ADAPTER
SECT.

BB
SECT.

TRIB.
8xE1
BASE
SECT.

TRIB.
2 Mbit/s (E1)

TRIB.
8xE1
EXP
SECT.

TRIB.
2 Mbit/s (E1)

STATION
BATTERY

ODU 2
Rx

DEM
Cable
INT.

Tx

MOD

LIU
SECT.
and
CABLE
INT.

CONTROLLER
SECT.

V INT.

6-4

F INT.

Q INT.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

6 - FUNCTIONAL DESCRIPTION

6.2 ODU ARCHITECTURE


The functional block diagram of ODU is given in Fig. 6.5.
Fig. 6.5

ODUs functional block diagram

ODU
Power supply BUS

ODU
CONTROLLER
Section

Power
Supply
Section

Base-Band
and cable
Interface
(BB-I)
Section

Control BUS

Signal BUS

MODEM
Section

Intermediate
Frequency
(IF)
Section

Radio
Frequency
(RF)
Section

Duplexer

RSSI

ODU-CABLE

Antenna Interface
ODUs external interfaces

6.2.1

BB-I ( Base-Band and Cable Interface ) Section


The BB-I section is in charge of the following tasks:

IDU-ODU cable base-band interface management

ODU power supply interface management

IDU-ODU low level signals exchange management

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

6-5

6 - FUNCTIONAL DESCRIPTION

6.2.2

Power Supply Section


The Power Supply section is in charge of the following tasks:

6.2.3

ODU's interfacing to external power supply (from ODU-CABLE interface)

Equipment's internal power lines conditioning and power distribution to third level
power supply sources.

Detection and management of alarms related to equipment's power supply system.

Modem Section
In Modem section there is a modulator capable to perform the suitable Modulation.
ODU HD/HP uses a 4 QAM Modem in HP mode and a 16 TCM Modem in HD mode.
ODU ND uses a 4 CPM Modem.

6.2.4

Controller Section
The Controller section is in charge of the following tasks:

6.2.5

Monitoring of ODU alarms and configuration.

ODU interfacing to IDU CONTROL section.

IF section
The "Intermediate Frequency" section is responsible of the following main tasks:

6.2.6

up-conversion to IF (Tx IF signal) of the input modulated signal generated by the


digital modulator, and delivery of the Tx IF signal to RF section;

down-conversion to in-phase and in-quadrature components and filtering of the IF


signal received from RF section; delivery of down converted signals to the digital
demodulator;

monitoring of the operating conditions of the IF circuits and of the integrity of the
internal interfaces, with generation of the associated alarms.

RF Section
The "RF" section is in charge of the following main tasks:

6-6

up-conversion to desired RF frequency of the incoming IF (modulated) signal,


output by "IF" section;

low-noise reception of the RF signal from far end radio transmitter;

down-conversion to desired IF frequency of the received RF signal from far end


radio transmitter.

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

6 - FUNCTIONAL DESCRIPTION

6.3 PROTECTION SYSTEM ARCHITECTURE


The equipment performs only the protection of the radio channel, i.e. the protection is
performed towards the 51.84 Mbit/s aggregate stream, and so the same
strategy/behaviour is applied both to the payload and to the service channels.

6.3.1

Radio Hardware protection logic


This logic, shown in Fig. 6.6, protects the system from hardware failures of Cable
Interface, ODU functionalities and performs the hardware protection from selective and
temporary link quality degradation e.g. the propagation fadings, but without to perform
the hitless protection.
The hardware protection logic allows the transmission to the antenna of the signal
coming from the unit with no alarm (Hot Standby config. TX side protection) and the
transmission to BB of the aggregate data stream coming from the radio channel with no
alarm (RX side protection).
The hardware protection logic generates the following commands:

HW SW CMD, that controls the RX switches.

RF SW CMD, that controls the RF TX switches.

The switch command RF SW CMD is generated by the LOGIC block in the Adaptor
assembler and sent to the correspondent ODU throughout the communication channel
between IDU and ODU.

Fig. 6.6

Alarms of Radio Hardware protection logic


to Prot. board
TX ODU Alm
Cable Interface

BB TX
Section

Adaptor
Assembler

LIU

Cable

Driver

Cable
Interface

RF TX
MOD

TX section

BB
Asic

BB RX
Section

RF SW CMD

Loc/Rem TX Alm
Loc/Rem RX Alm
(I/F Alm)

Adaptor
Disassemb.

LIU

Loc RDI Alm


RX ODU Alm

Cable
Receiv.

Cable
Interface

RF RX
DEM

RX section
HW SW CMD

IDU

ODU

from Prot. board

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

6-7

6 - FUNCTIONAL DESCRIPTION

When working automatically, the switching logic on IDU generates the switch command
using the following signals:

A summarized TX local failure alarm (local TX HW ALM): this alarm is set for
failures on the TX Section of Cable Interface (ODU) and for ODU failures.

A summarized TX remote failure alarm (remote TX HW ALM): this alarm is set for
failures on the TX Section of Cable Interface and ODU

A summarized RX local failure alarm (local RX HW ALM): this alarm is set for
failures on the RX Section of ODU and Cable Interface.

A summarized RX remote failure alarm (remote RX HW ALM): this alarm is set for
failures on the RX Section of ODU and Cable Interface.

The alarms above mentioned are active when the relevant communication channel
between IDU and ODU is not working or is disconnected.
The automatic protection logic may be overridden by setting from local operator
interface (PC) or from remote supervision system the following commands:

6-8

HW FM1: service forced for Local radio channel (Main)

HW FM2: service forced for Remote radio channel (Prot.)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

6 - FUNCTIONAL DESCRIPTION

6.4 SERVICE CHANNELS MANAGEMENT AND


PROTECTION
The radio service channels are:

USR

64
kbit/s,
V.11,
synchronous
co-directional
or
contra-directional channel, reserved for the user and
available on a public connector of the IDU front panel.

64 kbit/s synchronous contra-directional embedded channel,


reserved to transmit radio network supervision messages.

64 kbit/s, synchronous contra-directional channel, reserved to


transmit radio supervision messages, using a time slot of the
2 Mbit/s tributary. The channel is managed throughout the
Controller section in mixed radio/cable links. The Qtcp
protocol is used.

Dext

64 kbit/s, V.11, synchronous contra-directional channel,


managed by the Controller unit, in alternative to the 2Mbit/s
embedded D channel, to connect different equipment (e.g.
SDH) to the TMN supervision center. In this case the Qtcp
protocol is also used. The channel, available on a public
connector of IDU front panel, doesn't have protection.

Service channels are controlled throughout the functional blocks identified as "Services
Insert" and "Services Drop" as shown in the following figures.
In (1+1) Hot-Standby configurations, the same tributary is transmitted on both
aggregated radio channels. Service channel protection thus follows the same rule of the
tributary.

6.4.1

User channel (USR)


They are made up of the following signals:

Tab. 6.1

User channel
Signal type
User Data Tx: differential data input in the radio system, coming from
the public connector

USR CH
signal name
U-DTx1 a-b

User Contra-Directional Clock Tx: differential clock for data input in


the radio system (coming from the radio system)

U-CKTx1OUT a-b

User Co-Directional Clock Tx: differential clock for data input in the
radio system (coming from the public connector)

U-CKTx1-IN
a-b

User Data Rx: differential data output from the radio system

U-DRx1 a-b

User Clock Rx: differential clock for data output in the radio system
(coming from the radio system)

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

U-CKRx1 a-b

6-9

6 - FUNCTIONAL DESCRIPTION

The Fig. 6.7 shows the logical structures that allow the management of the USR
channels in the various configurations.
Fig. 6.7

Configuration of User channel

U-DTX 1

Services
Insert

U-CKTX -IN 1

U-CKTX -OUT 1

USR CH
HW SW CMD 1
U-DRX 1
U-CKRX 1

Services
Drop
BB SECTION

HW SW CMD 1

TRIBUTARY
SECTION
CONTROLLER
SECTION

6.4.2

Radio Embedded Communication Channel (R)


The R channel is managed throughout the Services Drop/Insert functional blocks of the
BB section and it is directly connected to the Controller section.

Fig. 6.8

Configuration of R channel

Controller Section

D & CK RX-1

Serial
Comm
Contr
CH

Services
Drop

DTX-1
CKTX-1

Services
Insert
BB SECTION

CONFIG

6-10

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

6 - FUNCTIONAL DESCRIPTION

6.4.3

Tributary Embedded Communication Channel (D)


The D channel is connected to the Controller section via Accesses section (see
Fig. 6.9).

Fig. 6.9

Configuration of D channel

D & CK RX -1

H.level
Data
Link
Control

Controller
Section

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

Services
Drop

DTX -1
CKTX -1

Services
Insert
BB SECTION

6-11

6 - FUNCTIONAL DESCRIPTION

6.5 LED, MONITORING POINTS, CONNECTORS


AND SWITCHES
In this paragraph are reported the operations of all the control and command elements
that are present on the front panels of the units making up the equipment.
Fig. 6.10 illustrates the front panel of the indoor assembly showing the LEDs, the
monitoring points, the connectors and the control elements.
The list and the function of the LEDs are reported in Tab. 6.2.
Fig. 6.10

IDU front panel in 1+1 configuration

10

1 - Power supply interface


2 - Cable Interface
3 - LAN Q & V Interface
4 - Tributary Interface
5 - Alarms Interface
6 - User/D channel Interface
7 - LCT Interface
8 - Memory key
9 - Toggle switch (PS ON/OFF)
10 - Signalling LEDs

6-12

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

6 - FUNCTIONAL DESCRIPTION

Fig. 6.11

LED position on the front panel of the Single Board IDU

Fig. 6.12

LED 1 and LED 2 position on the front panel of the Single Board IDU
LED 2

LED 1

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

6-13

6 - FUNCTIONAL DESCRIPTION

Tab. 6.2

Summary of the front panel LEDs


LED

Colour

ODU
Alarm

Red

CBL
Alarm

CH A

Meaning
General ODU alarm: lights up when an alarm is present on
the ODU or the ODU is disconnected.

Yellow CABLE alarm: lights up when current drain is lower than


expected. The causes might be due to the cable either
breaking down or being disconnected, or to absence of ODU.
Red

CABLE alarm: lights up when current drain is higher than


expected. The cause might be due to a short-circuit on the
cable or on the ODU.

Green

Lights up when the Base Band signal implements its own


normal path in both directions (Tx and Rx) (1+1 systems).

Yellow Lights up when the channel concerned is used with software


forcing.
CH B

Green

Lights up when the Base Band signal implements its own


normal path in both directions (Tx and Rx) (1+1 Systems).

Yellow Lights up when the channel concerned is used with software


forcing.
'
TEST

Red

General alarm inside: Card Fail alarm. It lights up also when


there are no internal power supply voltages.

Yellow Manual operation in progress: the LED lights up when the


equipment is not operating according to what configured, but
is "forced" into an unusual condition.

CRITICAL/
MAJOR

Red

Critical/ Major alarm: if ON it denotes the presence of a


Critical/Major" alarm inside the IDU, for which an immediate
(Critical) or urgent (Major) corrective action is required.

MINOR /
WARNING

Red

Minor/ Warning alarm: if ON it denotes the presence of a


"Minor/Warning" alarm inside the IDU, for which a corrective
action is not urgently required.

Note: On the RJ-45 connector of Q-LAN and V-LAN interfaces are present two LEDs
(green): LED1 (on the left of front view) signals the receiving status and LED2 signals
the connection status of the interface.

6-14

SRAL XD (single board IDU) - UMN


911-383/02C0000 - Issue 3, March 2004

PRINTED in ITALY

SRAL XD (single board IDU)

Low Capacity Digital Radio - 7...38 GHz

User Manual (UMN)


911-383/02C0000

SRAL XD (single board IDU)

D.45

D.55

Low Capacity Digital Radio 7...38 GHz

User Manual (UMN)

Issue 3, March 2004

SRAL XD (single board IDU)

SRAL XD (single board IDU)


Low Capacity Digital Radio 7...38 GHz

User Manual (UMN)


911-383/02C0000

Issue 3, March 2004

911-383/02C0000

D.25

Issue 3, March 2004

Low Capacity Digital Radio 7...38 GHz


User Manual (UMN)
911-383/02C0000

Issue 3, March 2004

D.30

SRAL XD (single board IDU)


Low Capacity Digital Radio - 7...38 GHz
User Manual (UMN)
911-383/02C0000

Issue 3, March 2004

D.20

SRAL XD (single board IDU)


Low Capacity Digital Radio 7...38 GHz
User Manual (UMN)
911-383/02C0000

Issue 3, March 2004

También podría gustarte