Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Clarification
Casing Spacer and
a Casing Isolator
are the same prod-
uct and serve the
same application
needs. Casing
Isolator was the
description that
originated in the
Energy Market,
dating back to the
late 1960s. In the
following manual,
Casing Spacer
will be the des-
cription used.
The Market or Industry has also used
the following descriptions below
refering to a Casing Spacer.
Chalks Pipe Isolators
Skids Pipe Supports
Spiders Clusters
Table of Contents
Casing Spacer - General Ordering Guidelines
Carrier Pipe Diameter Range Options Page 1
Carrier Pipe Insertion Length Page 1
Carrier Pipe Compatibility with Spacer Model Page 1
General Material Property Comparison Page 1
General Runner Height Options Page 2
Position Within Casing Options Page 3
PSI Casing Spacer Models - Non-Metallic
Model PE Casing Spacers Pages 4 - 5
Model HT Casing Spacers Pages 6 - 7
Model AZ Casing Spacers Pages 8 - 9
Ranger II
N
o
n
-
m
e
t
a
l
l
i
c
C
a
s
i
n
g
S
p
a
c
e
r
s
PSI Ranger II
Advantage
Installer and Shipping Costs
Ranger II - Maxi for 25.98 to 37.60 (660 to 955mm) Diameter Carrier Pipe
Band Width = 8.86 (225mm)
Carrier Pipe O.D. Range No. of Runner Height Options
Inches (mm) Segments Inches (mm)
25.98 to 30.79 (660 to 782) 6
30.79 to 37.60 (782 to 955) 7
1.50 1.97 2.56 2.95 3.54 3.94 4.92 5.91 6.89
(38) (50) (65) (75) (90) (100) (125) (150) (175)
Ranger II - Micro for 0.83 to 3.07 (21 to 78mm) Diameter Carrier Pipe
Band Width = 2.13 (54mm)
Carrier Pipe O.D. Range No. of Runner Height Options
Inches (mm) Segments Inches (mm)
0.83 to 1.14 (21 to 29) 3
1.14 to 1.54 (29 to 39) 4
1.54 to 1.85 (39 to 47) 5
1.85 to 2.24 (47 to 57) 6
2.24 to 2.48 (57 to 63) 7 1.50 1.97 2.56 2.95 3.54 3.94
2.48 to 3.07 (63 to 78) 8
(38) (50) (65) (75) (90) (100)
Ranger II - Mini for 2.48 to 5.51 (63 to 140mm) Diameter Carrier Pipe
Band Width = 3.15 (80mm)
Carrier Pipe O.D. Range No. of Runner Height Options
Inches (mm) Segments Inches (mm)
2.48 to 3.07 (63 to 78) 4
3.07 to 3.86 (78 to 98) 5
3.86 to 4.49 (98 to 114) 6
1.50 1.97 2.56 2.95 3.54 3.94 4.92
4.49 to 5.51 (114 to 140) 7 (38) (50) (65) (75) (90) (100) (125)
Ranger II - Midi for 5.51 to 16.65 (140 to 423mm) Diameter Carrier Pipe
Band Width = 5.12 (130mm)
Carrier Pipe O.D. Range No. of Runner Height Options
Inches (mm) Segments Inches (mm)
5.51 to 6.89 (140 to 175) 4
6.89 to 8.70 (175 to 221) 5
8.70 to 10.31 (221 to 262) 6
10.31 to 12.87 (262 to 327) 7
12.87 to 14.41 (327 to 366) 8
14.41 to 16.65 (366 to 423) 10
Ranger II - Medi for 16.77 to 25.98 (426 to 660mm) Diameter Carrier Pipe
Band Width = 6.87 (174 mm)
Carrier Pipe O.D. Range No. of Runner Height Options
Inches (mm) Segments Inches (mm)
16.77 to 21.22 (426 to 539) 4
21.22 to 25.98 (539 to 660) 5
1.50 1.97 2.56 2.95 3.54 3.94 4.92 5.91 6.89
(38) (50) (65) (75) (90) (100) (125) (150) (175)
Verify that Slide-Locks match segment size: Make sure (Mini) matches name
molded on the bottom of the Slide-Lock. Note: Micro & Mini segments
both use the Mini Slide-Lock.
Verify that Slide-Locks match segment size by checking to ensure the segment name (Mini) matches the name molded on bottom of the Slide-Lock.
Note: Micro & Mini segments both use the Mini Slide-Lock.
Verify that Slide-Locks match segment size by checking to ensure the segment name (Midi) matches the name molded on the bottom of the Slide-Lock.
Verify that Slide-Locks match segment size by checking to ensure the segment name (Maxi) matches the name molded on the bottom of the Slide-
Lock. Note: Medi & Maxi segments both use the Maxi Slide-Lock.
Verify that Slide-Locks match segment size by checking to ensure the segment name (Maxi) matches the name molded on the bottom of the Slide-
Lock. Note: Medi & Maxi segments both use the Maxi Slide-Lock.
R
a
n
g
e
r
I
I
N
o
n
-
m
e
t
a
l
l
i
c
C
a
s
i
n
g
S
p
a
c
e
r
s
PSI Ranger II
2
1
2
10
15
1
2
7
3
4
18
2X 4
1
2
2X 5
1
2
2X 4
3
4
10
3
4
2X 3
C/SlNG lD 41.000
MlN. CLE/F/NCE 1.00
4X 45
2X 30
0
0
270
2X C/FFlEF
CD 10.75
3X C/FFlEF
CD 4.50
4.0 SKlDS: 2WX 1.5H X 7L 307 GL/SS FlLLED FCLYMEF {5X)
3.0 CC/IlNG: CC/IED
2.0 8/NDS: 14G/. MlLD SIEEL 7L
1.0 FlSEFS: 10G/. MlLD SIEEL 7L
NCIES: UNLESS CIHEFWlSE SFEClFlED
180
FEV DESCFlFIlCN DF/WN /FFFCVED D/IE CH/NGE NC
1 CUSICMEF FEVlEW S. McC 10-0302
- - - -
FIFELINE, SEAL & INSbLAIOk INC.
SC/LE:
SlZE DWG. NC. 8
FEV.
SHEEI: 1 OF 1 WElGHI:
FkOFkIEIAkY AND CONFIDENIIAL 525 GcfcrIh SIreeI, Hcu:Icn, IX 77021
Ie|: 713-747-48 - Fcx: 713-747-02
D240xxx
C8GN2-10.750_
3-4.5_X41
1
DIMENSIONS AkE IN INCHES
ICLEF/NCES:
FF/CIlCN/L 1/1
/NGUL/F: 8END 1
IWC FL/CE DEClM/L .030
IHFEE FL/CE DEClM/L .005
IHE lNFCFM/IlCN CCNI/lNED lN IHlS
DF/WlNG lS IHE SCLE FFCFEFIY CF
FlFELlNE SE/L & lNSUL/ICF. /NY
FEFFCDUCIlCN lN F/FI CF /S / WHCLE
WlIHCUI IHE WFlIIEN FEFMlSSlCN CF
FlFELlNE SE/L & lNSUL/ICF lS
FFCHl8lIED.
CCMMENIS:
D/IE
DC NCI SC/LE DF/WlNG
ENGlNEEF
8Y {lNlIl/LS)
CHECKEF
C/
CCNIFCL
8C/FD
FlNlSH:
N//
M/IEFl/L:
SEE NCIES
SMC
LK
10-0302
www.pipe|ine:ec|.ccm
10-0302
Model C12GN2 used on (2) 24 C-905 Chilled
Water Lines going through a 60 casing.
Page 21
How to Order Metal Casing Isolators/Spacers
1. Quantity
2. Type Finish
3. Band Width
4. Runner Width
5. Carrier Pipe O.D. (Type and coating thickness if applicable)
6. Casing Pipe I.D. (Type and coating thickness if applicable)
7. Carrier Pipe Joint O.D. (If applicable)
8. Carrier pipe position within casing
9. Length of crossing
10. Contact your local distributor or
Pipeline Seal and Insulator, Inc.
Type Finish
C = Coated
S = 304 Stainless Steel
SL8 = Light Gauge 304 Stainless Steel
Band Width
8 = 8 Band
12 = 12 Band
Runner Width
G2 = 2 Wide Glass Reinforced Polyester Runners
GN2 = 2 Wide Glass Reinforced Nylon Runners
Carrier Pipe O.D.
Indicate actual O.D. including coating.
Casing Pipe I.D.
Indicate actual I.D. including coating.
Carrier Pipe Joint/Bell O.D.
(if applicable)
Indicate actual O.D. including coating.
Position within Casing
S = Standard
C = Centered
CR = Centered/Restrained
NCR = Non-centered/Restrained
C 12 GN2 17.40 x 23.25 - 20.00 - S
Example
Coated 12 (305mm) wide steel band casing spacer with 2
(50.8mm) wide glass reinforced nylon runners for a 16
(400mm) ductile iron pipe with a 17.40 (400mm) outside diam-
eter within a casing pipe with a 23.25 (590mm) inside diame-
ter, carrier pipe joint O.D. 20.00 (508mm), standard position.
Standard (to clear bell)
Centered
Centered/Restrained
Non-centered/Restrained
Min. 1 (25.4mm)
clearance
typical
Minimum 1
Clearance
Typical
Risers
GN2 Glass
Reinforced
Nylon
Runner
Sizes 4 thru 12
Sizes 14 thru 36
(Consult factory for larger sizes)
Ordering Procedure - Metallic Casing Spacers
O
r
d
e
r
i
n
g
P
r
o
c
e
d
u
r
e
M
e
t
a
l
l
i
c
C
a
s
i
n
g
S
p
a
c
e
r
s
Casing Spacer
Submittal Sheets
are available online at
www.pipelineseal.com.
PSI Casing Spacer Model A12GN-2 Submittal
A12GN-2 Material Specifications
Band
14 Gauge (0.074"[1.88mm]) x 12" (305mm) wide hot
rolled and pickled mild steel. Flanges of the spacer are
deep embossed and the corners are chamfered.
Configurations
4" (101.6mm) through 36" (914mm) = 2-piece (14 Ga)
38" (914mm) through 48" (1,219mm) = 3-piece (12 Ga)
Finish
Rust Inhibiting Paint
Liner
Material: Polyvinyl Chloride
Thickness: 0.090" (2.29mm) min.
Hardness: Durometer "A" 85-90
Dielectric Strength:
1/8" (3.18mm) Surge Test: 60,000 V min.
Step-by-Step Test: 58,000 V min.
Water Absorption: 1% max.
Risers
10 Gauge (0.135" [3.4mm]) steel MIG welded to band.
Runners
2" (50.8mm) x 7.0" (177.8mm) long glass reinforced
nylon runners.
Runner Configurations
4" (101.6mm) through 12" (305mm) = 2 Top - 2 Bottom
14" (356mm) through 36" (914mm) = 2 Top - 4 Bottom
38" (965mm) through 48" (1,219mm) = 8
Runner Specifications
Tensile Strength, (ASTM D638): 17,600 psi (1,237kg/cm)
Flexural Strength, (ASTM D790): 25,300 psi (1,779kg/cm)
Compression Strength, (ASTM D648): 18,000 psi (1,266kg/cm)
(10% Deformation)
Deflection Temp. @ 264 psi,
(ASTM D648): 405F (205C)
Deformation Under Load: @ 122F
(50C) 2000 lb. load - (ASTM D621): 1.2%
Studs, Nuts and Washers
Studs = 5/16" - 18 x 2-1/2" plated
Hex Nuts = 5/16"
Washers = 5/16" SAE 2330
Configuration = 8 studs, 16 nuts and washers
For additional PSI casing spacer models and warranty, view literature
online at: www.pipelineseal.com
6525 Goforth Street, Houston, TX 77021 U.S.A.
Tel: 713-747-6948 Fax: 713-747-6029
Toll Free: 800-423-2410 www.pipelineseal.com
email: info@psipsi.com
2010, Pipeline Seal and Insulator, Inc.
Pipeline Seal and Insulator, Inc.
A12GN-2 X
Carrier O.D. Casing I.D. Bell O.D. Position
Job/Project Name:
Customer:
P.O. Number: Date:
Submitted By: Date:
Approved By: Date:
NOTE: "S"
position = clear bell
only if applicable.
Risers may not be
required for all
applications. Runners
can be attached
directly to band.
Typical Configuration Examples
CAD - Drawings
Metallic Casing Spacers
are engineered, and CAD
drawings are available for
design discussions upon
request. Detailed CAD
drawings are provided
upon order placement.
For standard CAD cas-
ing/carrier pipe applica-
tions, drawings are
available online at
www.pipelineseal.com.
SIEEL FlSEF
SIEEL 8/ND
FCLYMEF FUNNEF
3/8 SIUDS
/ND NUIS
FVC LlNEF
IYFICAL CASING
SFACEk COMFONENIS
5.00
Cc:ing lD
42.00
Ccrrier CD
CenIerec
4X 3
4
2X 8 3
4
1 Min. C|ecrcnce
2X 45
2X 45
2X 15
c
0
180
270
4.0 SKlDS: 2WX 1.5H X 11L 307 GL/SS FlLLED FCLYMEF X
3.0 CC/IlNG: NCNE
2.0 8/NDS: 14G/ SI/lNLESS SIEEL 12L
1.0 FlSEFS: 10G/ SI/lNLESS SIEEL 11L
NCIES: UNLESS CIHEFWlSE SFEClFlED
FEV DESCFlFIlCN DF/WN /FFFCVED D/IE CH/NGE NC
1 FFCDUCIlCN FELE/SE S. McC 10-0405
FIFELINE, SEAL & INSbLAIOk INC.
SC/LE:
SlZE DWG. NC. 8 FEV.
SHEEI: 1 OF 1 WElGHI:
FkOFkIEIAkY AND CONFIDENIIAL 525 GcfcrIh SIreeI, Hcu:Icn, IX 77021
Ie|: 713-747-48 - Fcx: 713-747-02
D2000203
S12GN2_42.00X5.00
1
DlMENSlONS ARE lN lNCHES
TOLERANCES:
FRACTlONAL: 1/4
ANGULAR/BEND: 3
TWO PLACE DlMENSlONS: .030
PlPE DlMENSlONS: BY OTHER
IHE lNFCFM/IlCN CCNI/lNED lN IHlS
DF/WlNG lS IHE SCLE FFCFEFIY CF
FlFELlNE SE/L & lNSUL/ICF. /NY
FEFFCDUCIlCN lN F/FI CF /S / WHCLE
WlIHCUI IHE WFlIIEN FEFMlSSlCN CF
FlFELlNE SE/L & lNSUL/ICF lS
FFCHl8lIED.
CCMMENIS:
D/IE
DC NCI SC/LE DF/WlNG
ENGlNEEF
8Y {lNlIl/LS)
CHECKEF
C/
CCNIFCL
8C/FD
FlNlSH:
N//
M/IEFl/L:
SEE NCIES
S. McC
LK
10-0405
www.pipe|ine:ec|.ccm
Model "C" End Seals (For New Installations) Water/Energy Market
Model "C" Custom Pull-on End Seals are designed to accommodate custom carrier/cas-
ing diameter combinations. They are made to customer supplied specifications so they
may be used for any size casing/carrier differential. Manufactured from 1/8" thick specially
compounded synthetic rubber, PSI Model "C" end seals are extremely robust, resistant to
wide variations in environmental conditions while eliminating the possibility of foreign ma-
terial entering the opening between carrier and casing pipes.
Benefits/Features
Custom Made to Order
Quick and Easy Installation
Carrier Pipe Does Not Need To Be Centered Within Casing
Screwdriver Is Only Tool Required for Installation
Designed To Last for the Life of the Piping System
Heavy Duty Stainless Steel Hose Clamps Supplied
Model "R" End Seals and Night Caps (For New Installations) Water/Energy Market
Model "R" End Seals are available in five (5) different sizes to accommodate a wide range
of carrier/casing diameter combinations. A unique "cone" design, with molded-in dimen-
sions, are easily cut to size for a correct fit on the carrier pipe.
Benefits/Features
Low storage costs, only five end seal sizes to accommodate casings
from 4" (10.2cm) to 24" (61.0cm) in diameter with all applicable
carrier pipe sizes
May be easily stocked in 5 model sizes
Quick and Easy Installation
Manufactured from 1/8" (3.18mm) thick
high quality EPDM rubber
Casing night cap prevents entry of debris
and animals during install
Sizes are clearly printed on sleeve to
simplify cutting to the correct size
Designed to last for the life of the piping system
Stainless steel bands for clamping both ends
of end seal provided
May be used for new installations
NOTES:
Standard casing end seals are designed for below grade
applications. For above grade applications please
contact PSI.
LS = Link-Seal Modular Seals.
* = Contact PSI For Material Specifications.
1. High grade Buna-N material available for oil/gas run off.
1
Page 22
C
a
s
i
n
g
E
n
d
S
e
a
l
s
M
o
d
e
l
s
C
a
n
d
R
Casing End Seals
For Model R End Seal sizing,
download Model R literature.
www.pipelineseal.com
1.00 (25)
1.75 (45)
2.36 (60)
2.95 (75)
3.15 (80)
3.54 (90)
3.75 (95)
3.94 (100)
4.14 (105)
4.33 (110)
4.53 (115)
4.92 (125)
5.12 (130)
5.51 (140)
5.71 (145)
5.91 (150)
6.30 (160)
6.50 (165)
6.89 (175)
7.10 (180)
7.68 (195)
7.87 (200)
8.07 (205)
8.27 (210)
8.66 (220)
9.06 (230)
9.25 (235)
9.65 (245)
9.84 (250)
10.04 (255)
10.43 (265)
10.63 (270)
11.22 (285)
11.42 (290)
11.81 (300)
12.40 (315)
12.60 (320)
13.20 (335)
13.39 (340)
14.17 (360)
15.00 (380)
15.94 (405)
16.73 (425)
17.52 (445)
18.50 (470)
19.29 (490)
M
odel R
100
4-5 inch (110-135m
m
)
C
asing P
ipe
M
o
d
e
l R
4
0
0
F
o
r 1
4
- 1
6
in
c
h
(3
5
0
-4
0
2
m
m
) C
a
s
in
g
P
ip
e
D
ia
m
e
te
rs
M
o
d
e
l R
3
0
0
F
o
r 1
0
- 1
2
in
c
h
(2
7
0
-3
2
0
m
m
) C
a
s
in
g
P
ip
e
D
ia
m
e
te
rs
M
o
d
e
l R
2
0
0
F
o
r 6
- 8
in
c
h
(1
6
5
-2
1
5
m
m
)
C
a
s
in
g
P
ip
e
D
ia
m
e
te
rs
M
o
d
e
l R
5
0
0
F
o
r 2
0
- 2
4
in
c
h
(5
0
8
-6
1
0
m
m
) C
a
s
in
g
P
ip
e
D
ia
m
e
te
rs
Model R EPDM - Material Specification
Material EPDM 60
Thickness 1/8 (3.18mm)
Color Black
Temperature 250 F. (121 C.)
Hardware 304 Stainless Steel Bands with Worm Screws
Sizing Per Customer Specifications
Pipeline Seal and Insulator, Inc.
6525 Goforth Street, Houston TX 77021 U.S.A.
Telephone: 713-747-6948 Facsimile: 713-747-6029
Toll Free: 800-423-2410
www.pipelineseal.com www.ranger2.com info@psipsi.com
2009, Pipeline Seal and Insulator, Inc. All Rights Reserved RES-6/29/09
C
a
rrie
r P
ip
e
D
ia
m
e
te
rs
- In
c
h
e
s
(m
m
)
Five Models From Which To Choose
Select the appropriate end seal for your casing pipe O.D.
(colored bars below) then verify that your carrier pipe
O.D. is within the cones diameter range.
Tips for Installation
Simply cut the seals at the closed end to the measured
external diameter of the carrier pipe. (Note: The printed
sizes are marked on the end seals.) Push the end seal over
the outside of the casing pipe and the carrier pipe and
fasten with the included stainless steel bands.
Model "S" Standard Pull-on End Seals (For New Installations) Energy Market
Model "S" Standard Pull-on End Seals are flexible and easily installed on Nominal Steel & IPS
casing/carrier pipe combinations. PSI Model "S" end seals are extremely robust, resistant to wide
variations in environmental conditions while eliminating the possibility of foreign material entering
the opening between carrier and casing pipes.
Benefits/Features
Quick and Easy Installation
May be stocked
Screwdriver Is Only Tool Required for Installation
Designed To Last for the Life of the Piping System
Heavy Duty Stainless Steel Hose Clamps Supplied.
Model "W" Wrap Around End Seals (For New and Existing Installations) Water/Energy Market
Model "W" Wrap Around End Seals are designed to accommodate customer supplied specifications
so they may be used for any size casing/carrier differential. PSI Model "W" end seals are extremely
robust, resistant to wide variations in environmental conditions while eliminating the possibility of
foreign material entering the opening between carrier and casing pipes.
Benefits/Features
Custom Made to Order
Quick and Easy Installation
Carrier Pipe Does Not Need To Be Centered Within Casing
Can Be Installed on Existing Casing Installations
Screwdriver Is Only Tool Required for Installation
Designed To Last for the Life of the Piping System
Heavy Duty Stainless Steel Hose Clamps Supplied
Self-Curing Seam - Simply Remove Plastic Backing and Press Together
Model "FW" Fire Resistant End Seals (For New and Existing Installations) Energy Market
Model "FW" Fire Resistant End Seals have been developed for applications identified as fire prone
areas such as tank farms or pipes passing through fire walls. They are ordered to customer
supplied specifications so they may be used for any size casing/carrier differential. These seals are
excellent for eliminating the possibility of foreign material entering the opening between carrier and
casing pipes.
Benefits/Features
Custom Made to Order
Quick and Easy Installation
Carrier Pipe Does Not Need To Be Centered Within Casing
Screwdriver Is Only Tool Required for Installation
Designed To Last for the Life of the Piping System
Heavy Duty Hose Clamps Supplied
Standard casing end seals are designed for below grade applications.
For above grade applications please contact PSI.
Page 23
C
a
s
i
n
g
E
n
d
S
e
a
l
s
M
o
d
e
l
s
S
,
W
a
n
d
F
W
Casing End Seals
For Double Sealing Pipeline Casing
Ends when Carrier Pipe is Centered in
Casing
400 Series
For Casings Two Pipe Sizes Larger than Carrier Pipe
CARRIER
COMPLETE CASING SEAL
BASIC COMPLETE
X
ASSEMBLY CONSISTS OF:
LINK-SEAL ASSEMBLY
CASING PLAIN LINKS WITH TOTAL SIZE USED ORDER NO
PIPE LINKS CENTERING LINKS
IPS Nominal BLOCKS
2 X 6 5 0 5 LS-410 26*
3 X 6 7 0 7 LS-360 36*
4 X 8 7 0 7 LS-475 48*
6 X 10 10 0 10 LS-475 610*
8 X 12 12 0 12 LS-475 812*
10 X 14 10 0 10 LS-425 1014*
12 X 16 12 0 12 LS-425 1216*
14 X 18 9 4 13 LS-400 1418
16 X 20 11 4 15 LS-400 1620
18 X 22 13 4 17 LS-400 1822
20 X 24 13 5 18 LS-400 2024
22 X 26 16 5 20 LS-400 2226
24 X 28 17 5 22 LS-400 2428
26 X 30 17 6 23 LS-400 2630
28 X 32 18 7 25 LS-400 2832
30 X 34 20 7 27 LS-400 3034
32 X 36 21 8 29 LS-400 3236
34 X 38 22 8 30 LS-400 3438
36 X 40 24 8 32 LS-400 3640
* = Centering Blocks are not required and not available for these models.
(Maximum coating 3/16 thick - Casing pipe walls should not exceed 0.500
except for casing sizes 12, 14 and 16, which should not have a wall thick-
ness greater than 0.312)
** = Centering Blocks are not required for these applications.
(Maximum coating 3/16 thick - Casing pipe walls should not exceed 0.500
except for casing sizes 16 and 18 which should not have a wall thickness
greater than 0.312)
500 Series
For Casings Three Pipe Sizes Larger than Carrier Pipe
CARRIER
COMPLETE CASING SEAL
BASIC COMPLETE
X
ASSEMBLY CONSISTS OF:
LINK-SEAL ASSEMBLY
CASING PLAIN LINKS WITH TOTAL SIZE USED ORDER NO.
PIPE LINKS CENTERING LINKS
IPS Nominal BLOCKS
4 X 10 6 0 6 LS-500 410**
6 X 12 7 0 7 LS-500 612**
8 X 14 11 0 11 LS-575 814**
10 X 16 7 3 10 LS-525 1016
12 X 18 9 3 12 LS-525 1218
14 X 20 9 4 13 LS-500 1420
16 X 22 11 4 15 LS-500 1622
18 X 24 12 4 16 LS-500 1824
20 X 26 13 5 18 LS-500 2026
22 X 28 14 6 20 LS-500 2228
24 X 30 15 6 21 LS-500 2430
26 X 32 17 6 23 LS-500 2632
28 X 34 18 6 24 LS-500 2834
30 X 36 19 7 26 LS-500 3036
32 X 38 21 7 28 LS-500 3238
34 X 40 21 8 29 LS-500 3440
36 X 42 23 8 31 LS-500 3642
42 X 48 27 9 36 LS-500 4248
48 X 54 30 11 41 LS-500 4854
54 X 60 34 12 46 LS-500 5460
Link-Seal
modular seals
with Centering Blocks
Link-Seal
modular seals
with centering blocks in 25% of the
links. These centering blocks fit into
molded openings in the Link-Seal
M
o
d
u
l
a
r
S
e
a
l
s
Casing End Seals - Link-Seal
Modular Seals
If the seal doesnt appear to be
correct using the techniques pro-
vided, Call PSI at 713-747-6948
or 800-423-2410.
Installation Notes: The Link-
Seal
modular
seals are not intended to sup-
port the weight of the pipe.
2. Loosen rear pressure plate
with nut just enough so links
move freely. Connect both
ends of belt around the pipe.
3. Check to be sure all bolt
heads are facing the installer.
Extra slack or sag is normal.
Do not remove links if extra
slack exists. Note: On smaller
diameter pipe, links may need
to be stretched.
4. Slide belt assembly into
annular space. For larger size
belts, start inserting Link-Seal
modular seal assembly at the
6 OClock position and work
both sides up toward the 12
OClock position in the annu-
lar space.
5. Using a hand socket or off-
set wrench ONLY, start at 12
O Clock. Do not tighten any
bolt more than 4 turns at a
time. Continue in a clockwise
manner until links have been
uniformly compressed. (Ap-
prox. 2 or 3 rotations)
6. Make 2 or 3 more passes at
4 turns per bolt MAXIMUM,
tightening all bolts clockwise
until all sealing elements
bulge around all pressure
plates. On type 316 stainless
steel bolts, hand tighten ONLY
without power tool.
7. If the seal doesnt appear to
be correct using the instruc-
tions provided, Call PSI at
800-423-2410.
Link-Seal
M
o
d
u
l
a
r
S
e
a
l
s
Link-Seal
C
a
s
i
n
g
S
p
a
c
e
r
s
1. Size the Ranger II to
make sure you have all
the segments and Slide-
Locks. Refer to the siz-
ing chart on page 12.
Ranger II Casing Spacer Installation Techniques
Important Pre-Installation Factors:
A) Always wear protective safety glasses, especially in low temperatures.
B) Installation in Cold Climates: Keep Ranger II