KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau
Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com At photovoltaic plants, long lines or increasing energy consumption? Regulation of each single phase Higher capacities on request Quick regulation from 300-700 ms 34 till 300 kVA F : / P r o s p e k t e / N e t z r e g l e r / e n g l i s c h / 2 0 1 1 Vol tage Regul ator WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com 8V 230V 8V 230V 8V 230V 8V 230V 8V 230V 8V 230V Input Output L N 230 5V 0,3 0,5 1 1,5 2 3 km 70 60 50 40 30 20 10 kW Three-phase four-wire system 400/231V 5 0 m m 3 5 m m 2 5 m m 1 6 m m
Please request our materials,
we will gladly assist you. The Voltage Regulator measures and regulates the three phases individually, quickly and independent of one another. When idle or with an unloaded Voltage Regulator, the transformer stages that are not needed are bypassed. If the output voltage of the Voltage Regulator sinks below 225 volts due to load in the power supply lines, the required number of transformer stages in the affected phase are calculated and activated via the switch protectors. The bypass of the transformer stages to be switched is cancelled and the 230 volt winding is switched to the regulated line voltage. With excessive input voltage, which can occur due to starpoint shifts especially under load, the Voltage Regulator can regulate the voltage upwards by polarizing the windings, whereby a symmetrical output voltage between 235 and 225 V / phase is always guaranteed. This diagram depicts four common copper cross sections. The intersection with the km line provides the greatest possible performance for a range of +- 36V / phase, with which a complete regulation of the line voltage still occurs. Example: for voltage regulator +- 36V/ Phase Copper cross section q = 25mm Line length l = 1 km Intersection produces P = 31kW WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com 2 0 k V 0 , 4 k V 240m NAYY 4*120mm 180m NAYY 4*120mm 1230m NAYY 4*185mm line voltage regulator Imax 100A 150A 3 0 A 2 0 A 100A 180V 250 500 750 1500 200V 190V m 210V 240V 230V 220V voltage characteristics without line voltage regulator voltage characteristics with line voltage regulator line voltage regulator control range +- 5 V Adjustment of a spur line via a 69 kVA line voltage regulator Application of a line voltage regulator (blue curve). The voltage shape without line voltage regulator is shown in the red curve. Due to the voltage increase after the line voltage regulator, the current before the line voltage regulator has to be higher, according to the power balance chart before and after the line voltage regulator (P =constant =U*I), which results in a slight additional voltage drop in the line. 3
p h a s e
m e a s u r e m e n t
b e f o r e
t h e
v o l t a g e
r e g u l a t o r :
m e a s u r e m e n t
i n
5
m i n .
a v e r a g e
v a l u e s R e g u l a t e d
v o l t a g e
a f t e r
t h e
v o l t a g e
r e g u l a t o r :
m e a s u r e m e n t
i n
5
m i n
a v e r a g e
v a l u e s U
a v e r a g e
L 1
[ V ] U
a v e r a g e
L 2
[ V ] U
a v e r a g e
L 3
[ V ] t i m e R e c o r d i n g
o f
t h e
m i n .
u .
m a x .
v a l u e s ,
1 0
m s
s a m p l i n g B e f o r e
t h e
v o l t a g e
r e g u l a t o r A f t e r
t h e
v o l t a g e
r e g u l a t o r V o l t a g e
d r o p s
s m a l l e r
2 0 0
m s
c a n
n o t
b e
r e g u l a t e d
b y
t h e
v o l t a g e
r e g u l a t o r U
m i n
L 1 [ V ] U
m a x
L 1 [
V ] U
m i n
L 2
[ V ] U
m a x
L 2
[ V ] U
m i n
L 3
[ V ] U
m a x
L 3
[ V ] t i m e WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com 180V 250 500 750 1500 200V 190V m 210V 240V 230V 220V voltage characteristics with 950V - transformers voltage characteristics with line voltage regulator line voltage regulator control range +- 5 V 2 0 k V 2 0 k V 0 , 4 k V 0 , 4 k V 240m NAYY 4*120mm 1230m NAYY 4*120mm line voltage regulator Imax 100 A Imax 100 A 42 A 120 A 170 A 150 A 4 0 0
V 4 0 0
V 9 5 0
V 9 5 0
V A A B B Voltage shape with a tail with a line voltage regulator or 950 V transformers As can clearly be seen from the comparison of the two variations A and B, the voltage support with two 950V transformers only offers a conditional solution, as the voltage drop is only reduced by 58%. The solution via line voltage regulators, in contrast, enables a complete adjustment of the respective phase. WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com In the above diagram the transmission losses of the conventional networks for spur lines were compared with each other. To serve as an example, a 1500m NAYY line of 150 mm as taken as a basis for the calculations. The curves for the solution 20kV transformer take on the shape of scissor blades, as the 400V line length after the transformer considerably influences the transmission losses. Result: In general, the line voltage regulator is the most profitable transmission type for spur lines up to approx. 900 - 1000 hours of use. In comparison with the occasionally used 950 V version, the crossing of the two systems only appears after a service period of approx. 1800 hours which clearly is beneficial to the line voltage regulator. Profitability 2000 0 5000 1000 6000 7000 8000 9000 4000 hours of use 10000 11000 kWh 3000 2 0 0 4 0 0 1 4 0 0 6 0 0 1 6 0 0 8 0 0 1 8 0 0 1 0 0 0 2 0 0 0 2 2 0 0 1 2 0 0 2 4 0 0 h 9 5 0 V
c o n d u c t i o n 6 8
k V A
l i n e
v o l t a g e
r e g u l a t o r 2 0 k V
t r a n s f o r m e r 0 , 4
K V
l i n e
l e n g t h 2 0 k V
t r a n s f o r m e r WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com The diagram shows the load possibilities of spur lines NAYY via the use of a line voltage regulator with a control range of 6 x 6V steps (36V/ phase) . For the calculation it was assumed that at the end of the line, i.e. behind the line voltage regulator, an output voltage of 230 / 400V was adjusted as well. The calculation is based on cos-phi of about 0.9. The transmissible power can be further increased by the application of line voltage regulators with pre- stages and/or 8V steps, which could result in control ranges of +48V or also +64V / phase. See diagrams +48V and +64V Diagram NAYY + 36V WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com The diagram shows the load possibilities of spur lines NAYY via the use of a line voltage regulator with a control range of 6 x 8 V steps (48V/ phase) . For the calculation it was assumed that at the end of the line, i.e. behind the line voltage regulator, an output voltage of 230 / 400V was adjusted as well. The calculation is based on cos-phi of about 0.9. The transmissible power can be further increased by the application of line voltage regulators with pre-stages , which could result in control ranges of +64V / phase. See diagrams +64V Diagram NAYY + 48V WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com The diagram shows the load possibilities of spur lines NAYY via the use of a line voltage regulator with a control range of 6 x 8V steps and a pre - stage of 16 V (64V/ phase) . For the calculation it was assumed that at the end of the line, i.e. behind the line regulator, an output voltage of 230 / 400V was adjusted as well. The calculation is based on cos-phi of about 0.9. The transmissible power can be further increased by the application of line voltage regulators with additionel pre-stages. Diagram NAYY + 64V WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com Design and mode of operation The intention is to offset the voltage loss or the excessive voltages in the low-voltage networks (tail cabling!) through the automatic regulation. For this purpose, the line-voltage regulator is developed, which is created for installation outdoors as a result of its weatherproof design. The most common models are built for continuity currents of 50 to 200 A. The control range usually amounts to 36 V and/or 48 V in stages of 6 x 6 and/or 6 x 8 V in each phase. Greater voltage pulses up to 12 V per stage are possible. In particular cases the whole control range can be fundamentally extended again by preselector stages. Contact us about system problems, we would be happy to advise you. Design of the regulator Every three-phase current network regulator consists of three regulated transformer cascades independent of each other. A stored-program controller for rough climatic conditions computes the required number of the transformer stages to be actuated, and in the event of voltage fluctuations, switches these on or off as required, within a range of 300 500 ms. All the contactors are located in a collective casing, including the three reversing starter groups, which facilitate the input voltages to be regulated upwards or downwards with the same transformers. Each of the 6 x 6 V (8 V) stage transformers possess a primary coil of 230 V and a secondary coil of 6 or 8 V, by which the secondary coil, depending on the size of the system, is rated for 50 - 300 A (greater currents upon request). The contactors short-circuit the 230 V coils in the switched-off state. As a result, the individual transformer has no magnetisation losses at all in the no-load running. If required, the 230 V coil is connected to the voltage, by which the 6 V and/or 8 V coil is activated and this voltage is added to the incoming mains voltage (and/or subtracted from it). The excess voltages occasionally occurring with the activation of the transformers are shunted via switch arcs. Through damping resistors, which are housed in a separate box, the arc is lowered to an amperage harmless for the contactors. WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com The line- voltage regulator for the foundation installation is embedded in a double deep cable junction cabinet, suitable for the mounting on a normal base. Above left is the opened master control unit with the stored-program controller and guard casing. A measuring transducer activated before the stored-program controller converts the effective values of the 3 regulated voltages into a direct voltage suitable for the stored- program controller. Above right is the power section, comprising 6 stage transformers for each phase. Below are the NH fuse blocks for the fitting of the cable for a maximum of 95mm... On the left the line -voltage regulator is being prepared for dispatching. It is delivered mounted on wooden planks. This enables the line -voltage regulator to be easily transported with a fork-lift truck. To assemble on-site the roof can be unscrewed, so that you can access the transport eyes. The cabinet is accessible from two sides and therefore fitted with 4 doors for the integration of altogether 2 standard profile half cylinders. Line- voltage regulator Details WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com Design features: Offsetting of the voltage losses up to 25%, with the use of a preselector stage over 40%. Because of this, a multiplication of the cable load capacity is attained with adherence to the constant voltage. The high control rate, ca. 300 500 ms, for the whole control range. The start sequence with the heavy-running motors is normalised and/or once again possible. Symmetrical balancing of the phase voltages with the asymmetric load by the individual activation of each phase. Throughput rating: 34, 68, 136, 200 und 300 kVA. Control rate: 300 - 500ms. Individual activation of each phase: Because of this the asymmetries, the neutral displacements and voltage increases, determined by the uneven loads in the three phases, are balanced. Low-loss regulation: The efficiency factor lies at 98%. In the no-load running with all quantities the losses lie below 30 VA. Weatherproof design: The line- voltage regulators for the pole installation (sheet steel) are equipped with pole straps. The polyester design is suitable only for mounting on a foundation base. Maintenance-free operation: We recommend an inspection of the line -voltage regulator in intervals of one or two years. Module principle: Easy replacement possibility of all structural components. Economic efficiency: The line -voltage regulators have been in use for over 40 years. They have become reliable components of the system construction. It has been proven that the line- voltage regulator is not only suitable for temporary application, but also often durable as a final solution because of the high total efficiency. WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com line voltage regulator type NRF line voltage regulator type NRM WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com Line- voltage regulator in short-circuit Zeroing condition In the event of short-circuits behind the line -voltage regulator (K) the inherent resistance of the unit exerts only a low influence on the level of the short-circuit current. Picture: Equivalent network diagram Line- voltage regulator Through measurements on the various line -voltage regulators and in different systems with good approximation the intrinsic impedance of the 6-stage transformer series was measured with Z =0,06 bis 0,08 Ohms. The ohmic resistance lies between the values R =0.036 and 0.040 Ohms. The reactive impedance lies between the values X =0.05 and 0.07 Ohms. Picture: Transformer series (switched-off) Measurement results: Depending on the momentary closed-circuit condition of the line-voltage regulator, before the occurrence of the short circuit, the impedance of the loop fluctuates between 0.08 and 1.22 Ohms. After the decrease in the transformer contactors, as a result of the breakdowns of the voltage, the final resistance of approximately 0.08 Ohm is set within 10 to 20 ms. R L1 N R ( K ) R R X X X line-voltage-regulators WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com Connecting the line- voltage regulator L 1
I n p u t L 1
O u t p u t L 2
I n p u t L 2
O u t p u t L 3
I n p u t L 3
O u t p u t Clamps to bridge the line- voltage regulator N N Note: If the line- voltage regulator is put out of operation, the NH fuse blocks and meters are to be pulled. The jumpers can then be employed, with which the line- voltage regulator is galvanically decoupled from the mains network. If the power supply is not interrupted, all the automatic circuit breakers must be switched off. No more stage transformers may be switched on. This only works, if no voltage difference can be measured between the input and output. Check the measurements again!! Bag with jumper Base 730 GFK1 GFK2 WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com 1130 630 1 2 6 0 Base Base Line voltage regulator cabinet with 4 swivel doors Glass fiber reinforced polyester International protection: IP44 Prepared for the accomodation of 2 safety locks with a single-profile cylinder The base is not included in the standard (it can be supplied as an option) * measurement for socket-fitting WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com 1 3 0 0 560 780 1100 Cabinet M1 for mast-fitting The cabinet is planned for fitting on wooden-pole or girder-mast. We deliver two clamps as componente parts which provide easy and fast construction on the mast. It is useful to save the clamps respectively the cabinet on the mast with corresponding screws against wringing or slipping. WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com Technical Data General Data for all voltage regulators Temperature Range: -25C +45C Nominal voltage 3x230/400 V 50-60 Hz Regulation: 3 x one phase Regulation rate/ phase: typically 0,3 s max. 0,7 s Measuring system: root mean square (voltage) Regulation process: tap-change operation, system WALCHER Locking system: locks with a single-profile cylinder, safety lock Engineer standards: DIN EN 60204, DIN EN 60439-1, DIN VDE 0100, EMV guidelines: DIN EN 50081-1, DIN EN 50082-1 WA-NRH-x34 (+-36V) WA-NRH-x69 (+-36V) WA-NRH-x92 (+-36V) WA-NRH-xV34 (+48-24V) WA-NRH-xV69 (+48-24V) WA-NRH-xV92 (+48-24V) WA-NRH-x34 (+-48V) WA-NRH-x69 (+-48V) WA-NRH-x92 (+-48V) WA-NRH-xV34 (-48+24V) WA-NRH-xV69 (-48+24V) WA-NRH-xV92 (-48+24V) WA-NRH-x34 (+-60V) WA-NRH-x69 (+-60V) WA-NRH-x92 (+-60V) WA-NRH-xV34 (+64-32V) WA-NRH-xV69 (+64-32V) WA-NRH-xV92 (+64-32V) WA-NRH-xV34 (-64+32V) WA-NRH-xV69 (-64+32V) WA-NRH-xV92 (-64+32V) 34kVA 69kVA 92kVA 34kVA 69kVA 92kVA 34kVA 69kVA 92kVA 34kVA 69kVA 92kVA 34kVA 69kVA 92kVA 34kVA 69kVA 92kVA 34kVA 69kVA 92kVA 5,4kVA 10,8kVA 14,4kVA 7,2kVA 14,4kVA 19,2kVA 189-277V 189-277V 189-277V 177-259V 177-259V 177-259V 230+-5V 230+-5V 230+-5V 230+-5V 230+-5V 230+-5V ca. 20W ca. 20W ca. 20W ca. 80W ca. 140W ca. 240W ca. 20W ca. 20W ca. 20W ca.130W ca.180W ca.240W ca.130W ca.180W ca.240W ca. 20W ca. 20W ca. 20W ca. 80W ca. 140W ca.240W 580W 960W 1150W 740W 1300W 1500W Nominal power Type power Input voltage Output voltage Power losses no- load Power losses nominal load Weight kg Nominal load 98,3% 98,6% 98,7% 97,7% 98,2% 98,4% 250 350 410 280 410 490 7,2kVA 14,4kVA 18kVA 7,2kVA 14,4kVA 19,2kVA 9,0kVA 18kVA 24kVA 9,6kVA 19,2kVA 24kVA 9,6kVA 19,2kVA 24kVA 177-288V 177-288V 177-288V 201-283V 201-283V 201-283V 165-295V 165-295V 165-295V 161-267V 161-267V 161-267V 230+-6V 230+-6V 230+-6V 230+-5V 230+-5V 230+-5V 230+-8V 230+-8V 230+-8V 230+-6V 230+-6V 230+-6V 230+-6V 230+-6V 230+-6V 760W 1100W 1200W 740W 1300W 1500W 97,8% 98,4% 98,6% 97,7% 98,2% 98,4% 890W 1300W 1300W 1010W 1460W 1600W 1010W 1460W 1600W 97,4% 98,4% 98,6% 97,1% 97,9% 98,3% 97,1% 97,9% 98,3% 285 410 410 280 490 490 320 410 560 360 490 490 360 490 490 193-299V 193-299V 193-299V Voltage regulator 34 kVA Voltage regulator 69 kVA Voltage regulator 92 kVA WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com WA-NRH-F150 (+-36V) WA-NRH-F207 (+-36V) WA-NRH-F300 (+-36V) WA-NRH-FV150 (+48-24V) WA-NRH-FV207 (+48-24V) WA-NRH-FV300 (+48-24V) WA-NRH-F150 (+-48V) WA-NRH-F207 (+-48V) WA-NRH-F300 (+-48V) WA-NRH-FV150 (-48+24V) WA-NRH-FV207 (-48+24V) WA-NRH-FV300 (-48+24V) WA-NRH-F150 (+-60V) WA-NRH-F207 (+-60V) WA-NRH-F300 (+-60V) WA-NRH-FV150 (+64-32V) WA-NRH-FV207 (+64-32V) WA-NRH-FV300 (+64-32V) WA-NRH-FV150 (-64+32V) WA-NRH-FV207 (-64+32V) WA-NRH-FV300 (-64+32V) 150kVA 207kVA 300kVA 150kVA 207kVA 300kVA 150kVA 207kVA 300kVA 150kVA 207kVA 300kVA 150kVA 207kVA 300kVA 150kVA 207kVA 300kVA 150kVA 207kVA 300kVA 23,4kVA 32,4kVA 47kVA 31,2kVA 43,2kVA 62,5kVA 189-277V 189-277V 189-277V 177-259V 177-259V 177-259V 230+-5V 230+-5V 230+-5V 230+-5V 230+-5V 230+-5V ca. 40W ca. 50W ca. 60W ca. 220W ca. 300W ca. 240W ca. 40W ca. 50W ca. 60W ca.250W ca.300W ca. 240W ca.250W ca.300W ca. 240W ca. 40W ca. 50W ca. 60W ca. 220W ca. 300W ca. 240W 1600W 1900W 2500W 1700W 2500W 3300W 98,9% 99,0% 99,1% 98,8% 98,8% 98,9% 540 715 735 640 865 903 31,1kVA 43,2kVA 62,5kVA 31,2kVA 43,2kVA 62,5kVA 39,6kVA 54kVA 78,2kVA 42kVA 57,6kVA 83,3kVA 42kVA 57,6kVA 83,3kVA 177-288V 177-288V 177-288V 201-283V 201-283V 201-283V 165-295V 165-295V 165-295V 161-267V 161-267V 161-267V 230+-6V 230+-6V 230+-6V 230+-5V 230+-5V 230+-5V 230+-8V 230+-8V 230+-8V 230+-6V 230+-6V 230+-6V 230+-6V 230+-6V 230+-6V 2050W 2250W 4100W 1700W 2500W 3300W 98,6% 98,9% 98,6% 98,8% 98,8% 98,9% 2150W 2800W 5500W 2700W 3000W 5400W 2700W 3000W 5400W 98,5% 98,6% 98,2% 98,2% 98,6% 98,2% 98,2% 98,6% 98,2% 570 770 860 640 865 903 610 770 1040 750 883 1070 750 883 1070 193-299V 193-299V 193-299V Voltage regulator 150 kVA Voltage regulator 207 kVA Voltage regulator 300 kVA Temperature Range: -25C +45C Nominal voltage 3x230/400 V 50-60 Hz Regulation: 3 x one phase Regulation rate/ phase: typically 0,3 s max. 0,7 s Measuring system: root mean square (voltage) Regulation process: tap-change operation, system WALCHER Locking system: locks with a single-profile cylinder, safety lock Engineer standards: DIN EN 60204, DIN EN 60439-1, DIN VDE 0100, EMV guidelines: DIN EN 50081-1, DIN EN 50082-1 Technical Data General Data for all voltage regulators Nominal power Type power Input voltage Output voltage Power losses no- load Power losses nominal load Weight kg Nominal load WALCHER GmbH & Co.KG Kraftwerks-, Automatisierungstechnik, Energiemanagement,Transformatorenbau Zum Lingeshof 3 D 36124 Eichenzell Tel. +49 (0) 6659 98794-0 Fax. +49 (0) 6659 98794-44 info@walcher.com http://www.walcher.com Swi tchgear and contr ol systems Power pl ant technol ogy Fast (300- 700ms) vol tage r egul ator s 34- 200 kVA for l ong l ow vol tage l i nes Ener gy manage- ment Maxi mum demand moni tor s Datal ogger s for har moni cs and net anal ysi s Datal oggi ng Al ar m message and measur ement devi ces Tr ansfor mer s custom- made pr oducts El ectr oni cs assembl y wor k and devel opment We adapt our sel f to the r equi r ements of our customer s. Addr ess us !