Está en la página 1de 45

Mercury Medical ®

Intubation Catalog
2005/2006

11300 - 49th Street North


Clearwater, Florida 33762-4800
Telephone: 800-237-6418 • 800-835-6633

www.mercurymed.com
QUICK INDEX
Index Order.........................................................................................................................................................................................................1
CookGas® ILA™ Intubating Laryngeal Airway and Removal Stylet..............................................................................................2,3,4,5
2001 Fiberlight,® Lamp and Key .................................................................................................................................................................6,7
Laryngoscopes/Green German Profile Fiber Optic Systems...................................................................................................................8
Laryngoscopes/Green Coded Fiber Optic Systems ..................................................................................................................................9
Laryngoscopes/WisHipple/Wisconsin Blades (Fiber Optic) ....................................................................................................................10
Laryngoscopes/MRI Compatible Laryngoscope Systems......................................................................................................................11
Laryngoscopes/CLM™ ................................................................................................................................................................................ 12
Laryngoscopes/MacIntosh Flexible Tip Blades (Conventional Illumination) ..........................................................................................13
Laryngoscopes/MacIntosh Flexible Tip Blades (Fiber Optic)..................................................................................................................14
Laryngoscopes/UpsherScope Ultra® ....................................................................................................................................................15,16
Laryngoscopes/Mercury/Upsher®Fiber Optic Laryngoscopy Systems ..............................................................................................17
Laryngoscopes/Mercury/Upsher®Fiber Optic Handles...........................................................................................................................18
Laryngoscopes/Mercury Standard Handles (Adjustable Patil-Syracuse Handle, Howland Lock).......................................19
Laryngoscopes/Standard Blades (Miller, MacIntosh, Wisconsin) .............................................................................................................20
Laryngoscopes/Specialty Blades (Oxiport Miller, Phillips, Robert Shaw, Huffman Prism, I.V. MacIntosh,
Bizzarri-Guiffrida, Seward)...........................................................................................................................................................................21,22
Laryngoscopes/Cranwall™ Blades (Conventional Illumination) .........................................................................................23
Laryngoscopes/Cranwall™ Blades (Fiber Optic Illumination) ........................................................................................................................................................24
Laryngoscopes/Greenline/D Stainless Steel, Sterile, Disposable (Fiber Optic) Blades..............................................................................25
Conventional Laryngoscope Sets (American & English Profiles) ..........................................................................................................................26
Jet Ventilators ..........................................................................................................................................................................................................................27
Laryngoscope Lamps.....................................................................................................................................................................................28
Laryngoscope Accessories...........................................................................................................................................................................29
Accessories ................................................................................................................................................................................................................................................30
Stylettes (Lighted Intubation Stylettes, Illuminated Stylettes) ..........................................................................................................................................................31
Stylettes/Introducers/Bougies...............................................................................................................................................................................................................32
Nerve Stimulators (Peripheral Nerve Stimulator, Microstim Nerve Stimulator) ........................................................................................................................33,34
Airways/Oral/Nasopharyngeal (Color-Coded and Disposable Berman/Guedel/Nasopharyngeal/Latex-Free Robertazzi) ..................................................................35
Care and Cleaning of UpsherScope Ultra® Laryngoscope (Mercury/Upsher Blades and Handles) ..........................................................................................36
Care and Cleaning of Blades and Handles (Mercury Medical Waterproof Blades and Handles, Mercury Medical
Laryngoscope Blades and Handles, Mercury 2001 Fiberlight) ......................................................................................................................................................................37
StatCO2® and Mini StatCO2™ End Tidal CO2 Detectors .........................................................................................................................................................38,39
Troop Elevation Pillow™....................................................................................................................................................................................................................40,41
Warranty Information ...............................................................................................................................................................................................................................42
Notes Pages ..........................................................................................................................................................................................................................................43,44

ISO 13485

11300 - 49th Street North • Clearwater, Florida 33762-4800 • 800.237.6418 • 727.573.0088 • Fax: 800.990.6375
www.mercurymed.com

Mercury Medical® is a registered trademark of Mercury® Enterprises, Inc. ML2005-57 Rev. A

2
CookGas® ILA™ Intubating Laryngeal Airway and Removal Sylet

3
Cookgas® ILA™ Intubating Laryngeal Airway and Removal Sylet

Now you can intubate


through your routine airway.

The Cookgas ® ILA™ Intubating Laryngeal Airway

The only airway


you’ll want . . .

. . . the only one


you’ll need!

Dr. Daniel Cook, a practicing anesthesiologist, spent over 8 years developing the patented ILA, an improved supralaryngeal
airway. Placement is easy, air movement is outstanding and intubation, using standard oral endotracheal tubes (OETT’s), is
straightforward and reliable.

• The ILA can be used as your routine airway.

• The ILA allows for Intubation using standard oral endotracheal tubes, (sizes 5.0 - 8.5).

• Clinicians can easily remove the ILA with the ILA Removal Stylet without dislodging the ET tube.

• The ILA is reusable and can be autoclaved up to 40 times.

• The ILA Removal Stylet is reusable up to 10 times. The stylet is not autoclavable.

Reusable Intubating Laryngeal Airway (ILA)


3 Sizes Available
ORDERING INFORMATION:
Item # Size Description Quantity Patient Weight

#10-1025 2.5 Reusable Intubating Laryngeal Airway, 1 each 1/box 20 - 50 kgs


#10-1035 3.5 Reusable Intubating Laryngeal Airway, 1 each 1/box 50 - 70 kgs
#10-1045 4.5 Reusable Intubating Laryngeal Airway, 1 each 1/box 70 - 100 kgs
#10-1000 One Size Reusable ILA Removal Stylet 1/box
#10-1012 2.5 Airway Connector 10/pack
#10-1013 3.5 Airway Connector 10/pack
#10-1014 4.5 Airway Connector 10/pack

4
CookGas® ILA™ Intubating Laryngeal Airway and Removal Sylet

F E AT U R E S : BENEFITS:

3 ILA Sizes Available


• Airway Connector Ridges Generally the 2.5 is used on pediatric patients, The ridges below the airway connector
Improve Tube Seal. the 3.5 is used on small adults or female patients improve the tube seal. They also allow for
and the 4.5 is used on large adults or male patients. easy removal of the connector during
They are available in 1/2 sizes since these fit a
intubation through the ILA.
broader range of patients.

• Oval Shaped, Hyper-Curved The oval shape accommodates standard


Airway Tube with Decreased ET tube, (sizes 5.0 - 8.5), allowing for
Airway Tube Kinking. intubation. The hyper-curved airway tube
better approximates the anatomy of the
oral-pharyngeal passage eliminating the
tendency to “over bend” and kink the
airway tube.

• Reusable ILA. Up to 40 autoclave cycles.

• Auxilliary Airway Hole.


Improves air flow and prevents suction
effects from drawing the epiglottis inside
the airway tube. The unique design gently
elevates the epiglottis up allowing direct
access to the laryngeal inlet.

• 100% Latex Free. The Reusable ILA is manufactured with


medical grade silicone.

• One Piece Mask Construction. Eliminates unwanted seams.

• Keyhole-Shaped Airway Outlet. Directs OETT’s midline toward the laryn-


geal inlet. Also creates ample space for
other medical instruments used for
intubation.

• Mask Ridges Once the ILA cuff is inflated, the mask


ridges move against the posterior larynx
improving the anterior mask seal. This
helps isolate the esophagus reducing the
USA Patent No., ILA US 5,937,860 B1 potential for aspiration.
US 6,705,321 B2
USA Patent No., Stylet US 6,422,239 B1
• Innovative Tip Design. Canada Patent No., ILA/Stylet 2,231,331 Approximates the anatomic shape of the
Great Britain Patent No., ILA GB 2324040 B
Great Britain Patent No., Stylet GB 2357437 B posterior pharynx creating increased air-
Other USA and Foreign Patents Pending way stability, smooth insertion and
improved airway alignment.

5
CookGas® ILA™ Intubating Laryngeal Airway and Removal Sylet
CookGas® ILA™ Intubating Laryngeal Airway and Removal Sylet

ILA Removal Stylet


The ILA Removal Stylet is designed for the quick and easy removal of supralaryngeal airways following
oral-tracheal intubation through such devices.

The Stylet was specifically designed to be used in conjunction with the Intubating Laryngeal
Airway (ILA).

With its patented design, the Stylet stabilizes the previously-inserted oral endotracheal tube (OETT),
and allows controlled removal of the ILA without dislodging the OETT from the trachea.

Enlarged stylet tip

Removal Stylet
Tip Diagram

(A.) The taper allows the stylet to accommodate standard OETT’s in multiple sizes (5.0 - 8.5).

(B.) The ridges engage the OETT in a firm, secure grip, giving the user control of the OETT during the
ILA removal process.

(C.) The grooves allow spontaneously breathing patients unimpeded air passage within the OETT
during removal of the ILA.

(D.) The struts allow a more secure grip on the stylet during the rotational movement of insertion.

The reusable ILA Removal Stylet is manufactured with polypropylene for use up to 10 times.

Distributed by: Manufactured By: The Stylet is not autoclavable.

30 Day
Manufacturers Warranty (ILA)

All Components are Assembled and Manufactured in the U.S.A.

6
LARYNGOSCOPES 2001 Fiberlight®

A Fiber Optic Laryngoscope Blade That Fits On Your


Standard Handle,
is waterproof, and gives you more light!

The 2001 Fiberlight allows you to mix


Standard and Fiber Optic blades
avoiding handle compatibility issues.

Use your own standard handles with this blade. Save on the cost of
a new one. The engineering in the 2001 FIBERLIGHT ®
Laryngoscope kept the bulb in the blade.

By positioning the light in the bottom of the blade, flickering, cor-


rosion and the possibility of a loose bulb entering the oral airway
has been eliminated.

Equally important, there is no longer a hot bulb in the oral


cavity. Also, the bulb is easily accessible for checking or removal.
Light is located in the
bottom of the blade.

Special Feature Miller


Only

Light Source is now available on the right or left side.

*Standard laryngoscope handles with fittings manufactured to ASTM standards.

7
LARYNGOSCOPES 2001 Fiberlight®

Stainless Steel - Polished Finish

Light Type Of
Part # Description Size Position Patient
FEATURES:
• Mercury Medical offers a
#10-77607 F/O MacIntosh Size 1*** Infant
free repolishing service.
#10-77608 F/O MacIntosh Size 2*** Child
• Removable light bundles can
#10-77609 F/O MacIntosh Size 3*** Medium Adult be repolished extending blade
#10-77610 F/O MacIntosh Size 4*** Large Adult life - up to 3 times.
#10-77700 F/O Miller Size 0 Left Premature • Damaged light bundles can
#10-77701 F/O Miller Size 1 Left Infant be replaced at a fraction of
#10-77707 F/O Miller Size 2 Left Child the cost of a new blade.
#10-77702 F/O Miller Size 2 Right Child • Light bundle available on
#10-77708 F/O Miller Size 3 Left Medium Adult the right side for Miller #2,
#3 and #4.
#10-77703 F/O Miller Size 3 Right Medium Adult
#10-77709 F/O Miller Size 4 Left Large Adult • Design allows you to mix
standard and fiber optic
#10-77704 F/O Miller Size 4 Right Large Adult
blades.
#10-77800 F/O Phillips Size 1 Child
• Lifetime warranty against
#10-77801 F/O Phillips Size 2 Adult
manufacturer defects.
***Extended Flange

The 2001 FIBERLIGHT®


Laryngoscope Blade is
constructed of long-lasting
Stainless Steel (polished Bundles can be
finish). easily replaced by
simply unscrewing.
Mercury Medical,®
an Airway Management Company,
developed the 2001 Fiberlight
Laryngoscope Blade with you in mind, to Our light is in the blade,
save you money and give you brilliant Not in the handle!
light. Now you can use your own
Standard Laryngoscope handles
This fiber optic laryngoscope blade was with fittings manufactured to
made especially for your ASTM standards.
existing standard handles.* (Designed to fit Standard Handles)

#10-74300 Medium Handle (Waterproof)


#10-74302 Penlight Handle (Waterproof) #10-77301 2001
Replacement Lamp
The light is located
Note: Fiber Optic Repolishing Service is Available at no charge. Light bundles are in the bottom of the blade.
removable and can be repolished up to 3 times extending the life of the blade
and restoring light intensity.

The Light bundle is now available on the right or left side of the Miller #2, #3 and #4 blades.

8
LARYNGOSCOPES Green German Profile Fiber Optic Systems

Green German Profile

45 Degree View

FEATURES:
• Integral fiber bundle.
• 303/304 Surgical Stainless Steel.
• The lamp provides a very white, • Built with an integral extra large fiber optic
bright Light. bundle, providing more cool, white light.
• No cracks or crevices to trap
debris - helps to prevent cross • The design enables superior cleaning by
contamination. elimination of cracks and crevices.
• Cleaning/Sterilization, no adverse
effect in using ETO, steam • Compatible with all “Green” Fiber Optic
autoclaving, or by soaking in Systems.
Sporax, Cidex.
• Lamp is in the handle - providing
a protected light source.
MACINTOSH
• Handles - four available:
Medium, Penlight, Stubby and
#10-779-41 Green German F/O Size 1
Large.
#10-779-42 Green German F/O Size 2
• Large Fiber Optic Bundles offer
#10-779-43 Green German F/O Size 3
more light. #10-779-44 Green German F/O Size 4
• Green Coded Fiber Optic Blades
are compatible with Heine, AMS, MILLER
Propper, Welch Allyn, Rüsch-
Green Spec,® Sun Med-Greenline, #10-779-49 Green German F/O Size 00
Anesthesia Associates - Greenline. #10-779-50 Green German F/O Size 0
#10-779-51 Green German F/O Size 1
#10-779-52 Green German F/O Size 2
#10-779-53 Green German F/O Size 3
#10-779-54 Green German F/O Size 4

9
LARYNGOSCOPES Green Coded Fiber Optic Systems

FEATURES:
PLEASE NOTE: Green Coded Fiber Optic Handles
• Lightweight Stainless Steel Blades. and Blades are compatible with the following companies
• Four Handles available: Large, Medium (Standard), “GREEN” System Manufacturers:
Penlight and Stubby. Welch Allyn, Rusch-Green Spec, Propper,
• No Electrical Contact in the Blade - More Reliable. Heine, AMS, Sun Med-Greenline,
• New Fiber Optic Lamp - a Brighter, Cool, White Light. Anesthesia Associates - Greenline

Removable light bundle allows repolishing


or replacement, thereby extending the life of the blade.

FREE
45 Degree View
REPOLISHING
SERVICE

Not Shown
MACINTOSH - AMERICAN PROFILE
MACINTOSH EXTENDED FLANGE - ENGLISH PROFILE
#10-779-20 Newborn Size 0 75mm
#10-779-01 Infant Size 1 92mm
#10-779-21 Infant Size 1 87mm
#10-779-22 Child Size 2 108mm #10-779-02 Child Size 2 100mm
#10-779-23 Medium Adult Size 3 130mm #10-779-03 Medium Adult Size 3 130mm
#10-779-24 Large Adult Size 4 158mm #10-779-04 Adult Size 4 155mm

45 Degree View

MILLER - AMERICAN PROFILE

All illumination is on the left side of the blade.

#10-779-09 Premature Size 00 65mm


#10-779-10 Newborn Size 0 75mm
#10-779-11 Infant Size 1 102mm
#10-779-12 Child Size 2 155mm
#10-779-13 Medium Adult Size 3 195mm
#10-779-14 Large Adult Size 4 205mm

GREEN SYSTEMS FIBER OPTIC HANDLES


#10-779-16 Medium (Standard) Handle F/O
#10-779-17 Penlight Handle F/O
#10-779-18 Stubby Handle F/O
#10-779-19 Large Handle F/O
#10-719-79 Lamp Xenon 3.5mm

10
LARYNGOSCOPES WisHipple/Wisconsin Blades (Fiber Optic Illumination)

Laryngoscopes
Wis-Hipple/Wisconsin Blades
with Fiber Optic
Illumination

WIS-HIPPLE

Modification of the Wisconsin blade with a


circular flange. Compared to the Wisconsin
or Wis-Foregger blade, the flange tends to
be straighter and run parallel with the
spatula. This blade was designed primarily
for use in infants. The tip or beak of the
Wis-Hipple is wider and well adapted to
lifting the epiglottis. Three sizes are
available.

Wis-Hipple/Wisconsin Blades - Fiber Optic


Part # Size Description Dimensions
A B
#53-5-5234-00 0 Neonate 76mm 13mm
#53-5-5234-01 1 Infant 102mm 17mm
#53-5-5234-15 1.5 Small Child 115mm 14mm
#53-5-5234-20 00 Premature 67mm 12mm

Wisconsin

The Wisconsin blade with a staight spatula and


flange that expands slightly toward the distal
portion of the blade. This feature increases the
visual field and reduces the possibility of
trauma during intubation. The distal portion of
the blade is wider and formed slightly to the
right to better adapt to lifting the epiglottis.

All above blades are made from 303/304


surgical stainless steel and are provided
with 4mm, replaceable fiber optic bundles.
GreenLine® blades and handles are fully
compliant with ISO standard 7376-3 and
interchange perfectly with companies
conforming to the “Green System,” (i.e.,
Anesthesia Associates, AMS, Heine, Propper, Wisconsin - Fiber Optic
Rusch and Welch Allyn). Part # Size Description Dimensions
A B
#53-5-5234-02 2 Child 135mm 18mm
#53-5-5234-03 3 Medium Adult 162mm 17mm
#53-5-5234-04 4 Large Adult 199mm 21mm

11
LARYNGOSCOPES MRI Compatible Laryngoscope Systems

Fiber-Optic Intubating
Laryngoscope Set
for
MRI
Offering the first fiber-optic intubating laryngoscope set
designed specifically for use within the MR environment.

The Intubating Laryngoscope set has been developed through


extensive research into the requirements of both diagnostic and
interventional MR intubation.

The set has been tested in magnet field strengths up to 1.5


Tesla and has shown little or no deflection, image distortion or
heating during use.

The Laryngoscope’s high-intensity halogen lamp is powered by


a replaceable low-magnetic signature lithium battery (C size).
This advanced battery technology is designed to provide
approximately 8 hours life under continuous use. A typical
alkaline battery will provide less than 2 hours of use under
similar conditions.

Features include:

• Laryngoscope handle developed from selected low-magnetic materials.

• Specialized low-magnetic signature lithium battery capable of delivering


4 times the useful life of a standard alkaline battery.

• A 3.5v halogen lamp capable of producing a high intensity, fiber-optic


delivered light beam.

• Compatibility with a broad line of fiber-optic laryngoscope blades.

Size American English


Macintosh Macintosh Miller Wisconsin

0 CN-310100 N/A CN-310300 N/A


1 CN-310101 CN-310200 CN-310301 N/A
2 CN-310102 CN-310201 CN-310302 CN-310400
3 CN-310103 CN-310202 CN-310303 CN-310401
3.5 CN-310104 N/A N/A N/A
4 CN-310105 CN-310203 CN-310304 CN-310402

ITEM CATALOG #

MR Compatible Laryngoscope Handle CN-310001


MR Compatible Laryngoscope Handle - Short CN-310002
Lithium Battery - 2 Pack CN-310010
Halogen Lamp CN-310011

12
LARYNGOSCOPES CLM™ Laryngoscope (Fiber Optic Illumination)

CLM™ Laryngoscope
THE GENIUS IS IN THE TIP

MERCURY MEDICAL® is pleased to present the CLM (Corazelli,


London, McCoy) Laryngoscope Blade. The articulating tip on this
blade provides clinicians with greater flexibility and improved control,
particularly in cases of difficult intubation.

The Pediatric Blades, sizes 1 and 2, are based on the straighter


Seward Blade Design.

Features:
• Stainless steel construction.
• Autoclavable to 135oC.
• Waterproof.
• Non-glare finish.
• Easy lamp replacement.
• No special handle required.*
(SEE DIAGRAM BELOW)

• Replacement light bundles.

*Standard Laryngoscope handles manufactured to ASTM F965 standards.


Hook-on fitting in accordance with ISO 7376-1 and F965.

Flexibility During Difficult Intubations

The CLM™ Laryngoscope Blade is ideally suited for use in patients where
difficult intubations may occur, such as:

• Forward displacement of the larynx.

• Forward or prominent upper teeth.

• Backward displacement of the tongue.

• Enlarged tongue.

• Decreased neck movement.

• Cervical spine injuries.


Ordering Information:
• Decreased mouth opening.

• Recessive mandible. CLM Blade without waterproof handle.

In these situations, the force used during laryngoscopy may increase as #10-76216 CLM No. 1 Bulb Style
the degree of difficulty increases. The CLM Laryngoscope simplifies the #10-76217 CLM No. 2 Bulb Style
elevation of the epiglottis and the exposure of the larynx, thereby reducing #10-77802 CLM No. 3 Fiber Optic
the force employed. #10-77803 CLM No. 4 Fiber Optic
(Designed to fit Standard Handles)
#10-74300 Medium Handle (Waterproof)
#10-74302 Penlight Handle (Waterproof)

*References: Dr. EP McCoy and Dr RK Mirakur, The Levering Laryngoscope, Anesthesia. 1993. 48516-519.
Robert A. London, MD. The American Journal Of Anesthesia. “The Articulating Laryngoscope Blade.” Nov-Dec. 1995. 300 and 302. CLM™ is a trademark of Penlon Limited.

13
LARYNGOSCOPES MacIntosh Flexible Tip Blades (Conventional Illumination)

Laryngoscopes English Profile


with
Conventional Illumination

SUN-FLEX™
(Flexible Tip)

• Satin finish
• Extra bright reflector lamp
• English channel to help visualize
the epiglottis
• Surgical stainless steel construction
• Precise control to elevate the
epiglottis
• Tip has non-pinching design

Manufactured to provide both conventional


and fiber optic flexible laryngoscope blades.
Another product to assist you with difficult
intubations.

Blades made of surgical stainless steel.

Replacement Lamps
#53-5-0234-14
NEW! Parabolic Reflector Lamp
provides 40% more light.

MacIntosh Flexible Tip Blades/English Profile


with Conventional Illumination

Part # Size Description Dimensions

#53-5-5082-03 3 Medium Adult 132mm 25mm


#53-5-5082-04 4 Large Adult 155mm 26mm

Sun-Flex MacIntosh Kit

#53-5-5082-42 Sun-Flex MacIntosh Kit


KIT INCLUDES:

• Sun-Flex blades, sizes 3 and 4


• 1 medium chrome-plated handle
(stainless steel available)
• 1 extra reflector lamp
• Foam carrying case

14
LARYNGOSCOPES MacIntosh Flexible Tip Blades (Fiber Optic Illumination)

English Profile
Laryngoscopes
with
Fiber Optic Illumination

SUN-FLEX™
Green Fiber Optic
(Flexible Tip)

• Satin finish
• English channel to help visualize
the epiglottis
• Fiber optic bundle can be replaced
when service is required
• Stainless steel construction
• Precise control to elevate the
epiglottis
• Tip has non-pinching design

Manufactured to provide both conventional


and fiber optic flexible laryngoscope blades.
Another product to assist you with difficult
intubations.

Blades are made of surgical stainless steel.


MacIntosh Flexible Tip Blades/English Profile
with Fiber Optic Illumination
Part # Size Description Dimension

#53-5-5282-03 3 Medium Adult 132mm 23mm


#53-5-5282-04 4 Large Adult 155mm 26mm

Sun-Flex MacIntosh Kit

#53-5-5282-42 Sun-Flex MacIntosh Kit


KIT INCLUDES:

• Sun-Flex blades, sizes 3 and 4


• 1 medium chrome-plated handle
(stainless steel available)
• 1 extra reflector lamp
• Foam carrying case

All above blades are made from 303/304 surgical stainless


steel and are provided with 4mm, replaceable fiber optic
bundles. GreenLine® blades and handles are fully compliant
with ISO standard 7376-3 and interchange perfectly
with companies conforming to the “Green System,”
(i.e., Anesthesia Associates, AMS, Heine, Propper, Rusch
and Welch Allyn).

15
LARYNGOSCOPES UpsherScope Ultra®

An Improved Approach ...


to Difficult Intubations

Never Lose Sight


in a
Critical Situation!
NEW!
T i p D esign
ved
Impro C o m patible
Steri s

When you’re challenged with a difficult intubation,


the new UpsherScope Ultra® can help address the
situation by allowing direct visualization of the airway
through enhanced optics.

With the use of advanced fiber optics and an easy-


to-focus eyepiece, you are able to watch the
endotracheal tube as it passes between the vocal cords.

The new design and superior features of the


UpsherScope Ultra make it the instrument of choice
when faced with a challenging and difficult intubation.

16
LARYNGOSCOPES UpsherScope Ultra®

• The New UpsherScope Ultra provides brilliant fiber optics that provide a clear, direct view of the larynx
throughout an intubation. You can view the tube as it slides between the vocal cords.

• The UpsherScope Ultra also allows you to view the entire procedure on a monitor by using a snap-on camera for
remote viewing. This is excellent for both operating room procedures and for teaching purposes.

• Intubations can be a one-person job because the UpsherScope Ultra combines advanced fiber optic vision and a
tube-guiding blade, all in one instrument.

• The UpsherScope Ultra allows you to insufflate oxygen right down the endotracheal tube. You can inflate the cuff
and test the circuit while the tube is still in the scope.

• The slender profile will help you maneuver even in exceptionally tight spaces. The solid, Stainless Steel
construction provides the rigidity you need to guide the tube exactly where you want it.

• The optional Power Handle allows you to adapt to a fiber optic light source.

•Eyepiece with enhanced optics


also accommodates a television
monitor for remote viewing. Excellent
for both operating room procedures •The UpsherScope
and for teaching. Ultra snaps onto the
full line of Upsher
handles.

•Fiber Optic vision provides a


ORDERING INFORMATION view of the entire intubation.
When used properly, the
UpsherScope Ultra allows
Product # Description you to watch the tube as it
passes through the vocal cords.
#10-100-10 UpsherScope Ultra
with
Standard Handle
•No movable parts. •A built-in tube guide directs the
A reliable, sturdy endotracheal tube around the
#10-100-11 UpsherScope Ultra
with instrument that will last oropharyngeal curve with minimal
Stubby Power Handle for years with proper care. manipulation.
and Standard Handle

#10-110-00 Light Source


Improved Tip
Design
#10-110-06 Universal Camera
Adapter • Steris Compatible
• Fully Immersible
#10-110-05 Video Monitor
Power Handle Light Source
#10-100-02 Stubby Power Handle
with
4 Adapters

#53-9-0212-70 10/Box Introducer


15Fr. x 70cm with Coude Tip
BOUGIE Type Introducers, Disposable
#53-9-0212-72 10/Box Introducer
15Fr. x 70cm with Straight Tip

17
LARYNGOSCOPES MERCURY/UPSHER® Fiber Optic Laryngoscopy Systems

MERCURY/UPSHER® Fiber Optic Laryngoscopy Systems


SHEDDING MORE LIGHT ON THE SUBJECT...
• Largest assortment of interchangeable blades with Upsher handles.
• High-powered argon lamp provides up to four times the illumination of
many conventional lamps.
• No internal wiring to break, fray or corrode.
• Compatible with other standard blades that have hook-on fittings in
accordance with ISO #7376-1 and ASTM #F965 standards.
• Water-resistant handles.
• Low maintenance.
• Can be used with light source and Power Handle for maximum
luminescence in viewing a traumatized airway.
Maximum reliability and
longevity in an instrument
you’ll want to use for years.

MERCURY/UPSHER Blades

Part # Description Size Part # Description Size

#10-190-10 MacIntosh Blade #1


#10-292-00 Miller Blade #0
#10-190-20 MacIntosh Blade #2
#10-292-10 Miller Blade #1
#10-190-30 MacIntosh Blade #3
#10-192-20 Miller Blade #2
#10-190-90 MacIntosh Blade #3.5
#10-192-30 Miller Blade #3
#10-190-40 MacIntosh Blade #4
#10-192-40 Miller Blade #4

Specialty Blades

Part # Description Size

#10-196-10 ULX MacIntosh Blade #1


#10-196-20 ULX MacIntosh Blade #2
#10-196-30 ULX MacIntosh Blade #3
#10-196-40 ULX MacIntosh Blade #4
#10-197-20 IV MacIntosh Blade #2
#10-197-30 IV MacIntosh Blade #3
#10-197-40 IV MacIntosh Blade #4
Area of Improved
Vision with IV
MacIntosh

Note: Fiber Optic Repolishing Service is Available at no charge. Light bundles are
removable and can be repolished up to 3 times extending the life of the blade
and restoring light intensity.

18
LARYNGOSCOPES MERCURY/UPSHER® Fiber Optic Handles

MERCURY/UPSHER Fiber Optic Handles

The MERCURY/UPSHER Universal Handle® is the ultimate in versatility.


The uniquely designed handle is compatible with the Mercury/Upsher
fiber optic blades and most standard bulb type blades.

Get A Grip

• Fits Upsher Fiber Optic Blades


• Fits Most Standard Bulb Blades
#10-19250 #10-18000 #10-19150
Stubby Standard Penlight
Universal Universal Universal
Handle® Handle® Handle®

The same toughness and lightweight feel of the standard


Upsher Universal Handle - in less than half the size!
Introducing the Upsher Micro-GripTM - only 3-1/4” high
Perfect for crash carts and C-Sections, this ultra-light #10-20030
handle fits snugly into your palm. It’s the breakthrough Micro-Grip
Universal
that finally makes the laryngoscope what it was meant Handle™
to be ... a comfortable, easy-to-maneuver extension of
your hand. It’s long life lithium batteries make it ready
whenever you need it.

Upsher Universal Handles

Part # Description Battery Size

#10-180-00 F/O Standard Handle, lightweight 2 “C” batteries


#10-191-50 F/O Penlight Handle 2 “AA” batteries
#10-192-50 F/O Stubby Handle 2 “AA” batteries
#10-200-30 F/O Micro-Handle Lithium battery, (#72-DL123AB)
#10-100-02 Stubby PowerHandle w/4 Light Source Adapters, i.e., Olympus, ACMI, Wolf and Stortz

Part # Description Stubby Power Handle


attached to UpsherScope®
Lamps
#10-190-80 Replacement Lamp (black insulator)
#10-200-80 Replacement Lamp (white insulator)
#10-200-85 Replacement Lamp (blue insulator)

19
LARYNGOSCOPES MERCURY Standard Handles

LARYNGOSCOPE
STANDARD
BLADE
#10-74302 Penlight Handle
HANDLES (Waterproof) accepts two
“AA” batteries, 140mm
#10-74114 Large Handle
#10-74115 Standard accepts two “D” batteries,
Penlight Handle accepts two 172mm
“AA” batteries, 140mm

#10-74303 Stubby #10-74304 Stubby Handle #10-74300 Medium Handle


Penlight Handle (Waterproof) - accepts two (Waterproof) accepts two “C”
(Waterproof) with 2 “N” “AA” batteries, 103mm batteries, 143mm
batteries, 115mm
#10-74309 Standard Stubby #10-74015 Standard Medium
#10-74400 Standard Handle - accepts two “AA” Handle accepts two “C” bat-
Stubby Penlight Handle batteries, 103mm teries, 143mm
with 2 “N” batteries,
115mm

ADJUSTABLE HOWLAND LOCK


PATIL-SYRACUSE HANDLE

ABLE
T
#19-00-340 This handle allows the blade to LOCK O
I
be positioned and locked in four different DIFFE N 4
R
positions: 180,o 135,o 90,o standard or 45o POSIT ENT
IONS!
(Howland Lock Angle). In the 180o posi-
tion, the blade can be introduced parallel to
the handle when extension of the neck is
contraindicated because of cervical spine
fractures or instability. Visualization of the
larynx is also facilitated in obese patients or
those in halo traction. In the 45o position,
all advantages of the Howland Lock are #10-73017 Natural lifting action simplifies
achieved. The handle accepts two “AA” laryngeal exposure, making intubation
batteries and fits all hook-on type possible even in the most difficult cases.
laryngoscope blades. The overall length Built-in leverage prevents prying and
and weight of the handle is approximately reduces the possible loss of broken teeth.
the same as that of a conventional handle. Adapts to all types of hook-on laryngoscope
handles and blades. Can often make an
otherwise certain tracheostomy
unnecessary.

20
LARYNGOSCOPES Standard Blades

Miller Miller - American Profile


Light Overall
Part # Description Size Position Length

#10-75208 Premature Size 00 Left 57mm

The most popular of the straight blade types. The #10-75200 Neonate Size 0 Left 75mm
side of the flange is reduced to minimize trauma and #10-75201 Infant Size 1 Left 102mm
the curve at the beak or tip is extended to improve #10-75202 Child Size 2 Right 155mm
lifting of the epiglottis. These improvements facilitate #10-75203 Med Adult Size 3 Right 195mm
greater exposure of the larynx in difficult-to-intubate #10-75204 Lg Adult Size 4 Right 205mm
patients.

MacIntosh
MacIntosh - American Profile
Light Overall
Part # Description Size Position Length

#10-75000 Premature Size 0 Left 78mm


#10-75001 Infant Size 1 Left 87mm
#10-75002 Child Size 2 Left 100mm
The MacIntosh is the predominant choice of the #10-75007 Child Size 2.5 Left 118mm
curved blade types. During laryngoscopy, the tip or
#10-75003 Med Adult Size 3 Left 130mm
“beak” of the blade is compressed into the angle
formed by the base of the tongue and the epiglottis #10-75005 Adult Size 3.5 Left 144mm
(vallecula), indirectly raising the epiglottis. #10-75004 Adult Size 4 Left 155mm

The MacIntosh Extended Flange spatula of the MacIntosh-Extended Flange-English Profile


blade has a smooth and gentle curve extending Light Overall
from the lock to the tip. In cross section, the Part # Description Size Position Length
construction resembles that of a Z flange,
facilitating greater access during intubation. #10-78004 Neonate Size 0 Left 80mm
#10-78005 Infant Size 1 Left 92mm
#10-78006 Child Size 2 Left 100mm
#10-78007 Med Adult Size 3 Left 130mm
#10-78008 Adult Size 4 Left 155mm

Extended Flange Blades all use Standard Large Lamps.

Wisconsin Wisconsin
Light Overall
Part # Description Size Position Length

#10-75105 Premature Size 0 Left 80mm


#10-75101 Infant Size 1 Left 102mm
#10-75100 Infant Size 1.5 Left 115mm
#10-75102 Child Size 2 Left 135mm
#10-75103 Med Adult Size 3 Left 162mm
The Wisconsin Laryngoscope Blade offers a straight
spatula and a flange that expands slightly toward the #10-75104 Lg Adult Size 4 Left 199mm
distal portion of the blade. This feature increases the
visual field and reduces the possibility of trauma
during intubation.

21
LARYNGOSCOPES Specialty Blades

Oxiport Miller

Part # Description Size


The Oxiport is a modification of the Miller or MacIntosh Blade that allows an #53-53078-00 Premature Size 0
individual to perform a laryngoscopy and intubation with less risk of hypoxia.
#53-53078-01 Infant Size 1
A tube is built into these blades that permits delivery of O2 or other gas
mixtures during intubation.

Phillips
Overall
Part # Description Size Length

The Phillips Laryngoscope® Blade integrates the straight Jackson #53-53073-01 Pediatric Size 1 113mm
blade design with the curved distal tip Miller design, providing #53-53073-02 Adult Size 2 166mm
greater visibility and an almost direct line approach to the trachea
during difficult intubations. Unique lamp mounting provides deep
illumination downward and inward, while the low profile flange
reduces the risk of oral damage.

Robert Shaw
Overall
Part # Description Size Length

This blade for infants and children is gently curved over the distal third #53-55077-00 Neonatal Size 0 94mm
and is designed to lift the epiglottis indirectly in the manner of the #53-55077-01 Infant Size 1 112mm
Macintosh blade. The blade section permits binocular vision thus
allowing better judgement of depth and consequently less risk of
trauma.

Huffman Prism

Part # Description Size


Clipped to the vertical wall of an Adult size 2, 3 or 4 MacIntosh #19-003494 For MacIntosh #4
Blade, this device is used when the view of the vocal cord is #19-003493 For MacIntosh #3
impaired during nasal intubation and for post-operating examination #19-003492 For MacIntosh #2
of the larynx. It consists of an optically polished prism which
provides a refraction of 30o. To prevent condensation, warm the
prism before use by immersing it, (attached to the laryngoscope) in
water at about 48oC (120oF).

22
LARYNGOSCOPES Specialty Blades

E/C - E-MAC™ English Channel


E-MacIntosh w/tube Guide

A modification of the “English” style Part # Description Size


MacIntosh laryngoscope blade. A
#53-5-5046-02 Eng. Channel E-Mac Child Size 100mm
channel in the blade provides a means #53-5-5046-03 Eng. Channel E-Mac Medium Adult 130mm
through which an endotracheal tube may Size 3
be inserted after visualizing the cords. A #53-5-5046-04 Eng. Channel E-Mac Large Adult 155mm
new parabolic reflector lamp provides four Size 4
times more light. #53-5-5046-35 Eng. Channel E-Mac Extended 144mm
Adult Size 3-1/2

Bizzarri-Guiffrida*
(Flangeless MacIntosh)

Part # Description Size mm


A modification of the Macintosh Laryngoscope Blade with the #53-53072-03 Med Adult Size 3 130mm
flange eliminated to minimize the danger of damage to teeth, #53-53072-04 Large Adult Size 4 158mm
facilitates laryngoscopy of patients with limited mouth opening
because of disease, injury, deformity, etc., and permits maximum
anterior rotation of the distal end of the blade. Minimum discomfort
when used on a conscious patient. Excellent for laryngoscopy of
patients with protruding teeth, receding jaw, “bull neck” or larynx
located in an extreme anterior anatomic position.

Seward*

Part # Size mm
Originally produced as an infant blade for use in asphyxia #53-55079-01 Size 1 105mm
neonatorum, this pattern is now available in two sizes
#53-55079-02 Size 2 130mm
extending its usefulness to older children.

* Specialty Blades require four to six weeks delivery time.

23
LARYNGOSCOPES Cranwall™ Blades (Conventional Illumination)

Laryngoscopes American Profile


with
Conventional Illumination

CRANWALL™
A modification of the Miller that retains the
extended curved tip to facilitate in lifting the
Cranwall™ Blades with Conventional Illumination
epiglottis.
A B
The Cranwall blade has dramatically reduced the #53-5-5063-00 0 Neonate 75mm 6mm
#53-5-5063-01 1 Infant 100mm 6mm
flange to allow insertion through a restricted
#53-5-5063-02 2 Child 157mm 8mm
opening, such as arthritic jaw or facial burns and #53-5-5063-03 3 Medium Adult 195mm 9mm
decreases potential for damage to the upper
teeth.

This blade has the flange removed directly below


the light carrier. Blades made of surgical stain-
less steel.

Replacement Lamps
53-5-0234-01 ... Sizes # 0, 1, 2, 3

24
LARYNGOSCOPES Cranwall™ Blades (Fiber Optic Illumination)

Laryngoscopes American Profile


with
Fiber Optic Illumination

CRANWALL™
A modification of the Miller that retains the
extended curved tip to facilitate in lifting the
epiglottis.

The Cranwall blade has dramatically reduced the


flange to allow insertion through a restricted
opening and decreases potential for damage to
the upper teeth. For use with arthritic jaw or
facial burns.

Cranwall™ Blades with Fiber Optic Illumination

A B
#53-5-5236-00 0 Neonate 75mm 10mm
#53-5-5236-01 1 Infant 100mm 11mm
#53-5-5236-02 2 Child 157mm 11mm
#53-5-5236-03 3 Medium Adult 195mm 12mm

All above blades are made from 303/304


surgical stainless steel and are provided with
4mm, replaceable fiber optic bundles.
GreenLine® blades and handles are fully
compliant with ISO standard 7376-3 and
interchange perfectly with companies conforming
to the “Green System,” (i.e., Anesthesia
Associates, AMS, Heine, Propper, Rusch and
Welch Allyn).

25
LARYNGOSCOPES GREENLINE/D Stainless Steel, Sterile, Disposable Fiber Optic Blades

Disposable, Stainless Steel, Sterile,


Laryngoscopes Fiber Optic Blades
with
Fiber Optic Illumination

Miller - Patent Pending

Part # Size Description Dimensions Pkg.


GREENLINE®/D™ A B
#53-5333-00 0 Neonate 77mm 10mm 20/Bx
The GreenLine/D disposable laryngoscope #53-5333-01 1 Infant 102mm 10mm 20/Bx
blades solve contamination problems and #53-5333-02 2 Child 153mm 12mm 20/Bx
eliminate the cost and time spent cleaning #53-5333-03 3 Medium Adult 195mm 16mm 20/Bx
laryngoscope blades and returning them for
use.

• Made of surgical stainless steel


• Suitable for everyday hospital use
• Answers the professional’s request for
a non-plastic disposable
• Perfect solution to cleaning problems
confronting EMS field
• Polished acrylic stem produces
exceptional illumination
• Used with a reusable “Green” system fiber
optic handle. Compatible with: AMS,
Anesthesia Associates, Heine, Propper,
Rusch and Welch Allyn
• Sterile pack 20/box MacIntosh Patent Pending

Part # Size Description Dimensions Pkg.

A B
#53-5-5332-02 2 Child 100mm 21mm 20/Bx
#53-5-5332-03 3 Medium Adult 130mm 22mm 20/Bx
#53-5-5332-04 4 Large Adult 155mm 25mm 20/Bx

26
CONVENTIONAL LARYNGOSCOPE SETS (American & English Profiles)
Conventional Laryngoscope Sets
American & English Profiles

MacIntosh American Profile Miller American Profile MacIntosh/Miller English


Profile Combination Set

MacIntosh American Profile Set


Features: #53-5-5052-44 Set includes: Medium Handle, 2 extra lamps
and MacIntosh Blades, Size: 1, 2, 3, 4
• Blades made of 303/304 surgical
stainless steel
MacIntosh English Profile Set
• High impact plastic case - for ease #53-5-5051-44 Set includes: Medium Handle, 2 extra lamps
of transport and MacIntosh Blades, Size: 1, 2, 3, 4
• MacIntosh - Miller sets are available
• Complete sets of most popular Miller American Profile Set
laryngoscope blades #53-5-5062-45 Set includes: Medium Handle, 2 extra lamps
• Medium handle and two extra and Miller Blades, Size: 0, 1, 2, 3, 4
lamps included
• Kits supplied with chrome plated Miller English Profile Set
handle (stainless steel also available) #53-5-5061-45 Set includes: Medium Handle, 2 extra lamps
• Most economical and Miller Blades, Size: 0, 1, 2, 3, 4
• 5-year warranty (excludes lamp)
• Convenient MacIntosh/Miller Combination Set - American
Profile
#53-5-5062-47 Set includes: Medium Handle, 2 extra
lamps and MacIntosh Blades, Size: 2, 3, 4
and Miller Blades, Size: 0, 1, 2, 3

MacIntosh/Miller Combination Set - English


Profile
#53-5-5061-47 Set includes: Medium Handle, 2 extra
lamps and MacIntosh Blades, Size: 2, 3, 4
and Miller Blades, Size: 0, 1, 2, 3

27
JET VENTILATORS

Manual Jet Ventilator Kit


#GZ-BE 183-SUR

The Manual Jet Ventilation Kit comes complete with


Regulator, Gauge, On/Off valve, 6-ft., High Pressure
Tubing and 4 ft., Small Bore Tubing.

Note: Optional tubing lengths are available upon


special order requests.

Features:
• Reusable, lightweight, portable and durable.
Parts and Accessories:
• On/Off spring valve provides flow when
pressed and stops flow when released.
#GZ-BE 183-2 4 ft. Small Bore Tubing
• Can be used in conjunction with needle #GZ-BE 183-6 6 ft. High Pressure Tubing
cricothyrotomy to ventilate patients.
#GZ-BE 183-G Gauge
• A necessity for emergency rooms, crash #GZ-BE 183-R Regulator and Gauge
carts and ambulances.
#GZ-BE 183-SU Ventilator Kit without Regulator or Gauge

15mm tracheal
tube connector
Tracheal or
tracheostomy tube

#19-00325 A ventilating system for rigid-wall bronchoscopy and


laryngeal microsurgery consisting of 5’ high-pressure tubing #04-600101 Jet Ventilator Adapter,
with DISS fitting, flow control valve, thumb control valve, Single Use
pressure gauge, and 20” clear plastic tubing with Luer fitting for
attachment of adapters and tubes.

28
LARYNGOSCOPE LAMPS

Laryngoscope Lamps

#10-71907 Ea. #10-71901 5/Pkg #10-71906 Ea. #10-71902 5/Pkg


Small - Frosted Small - Prefocused Large - Frosted Large - Prefocused

#10-71907 Standard, Small, Frosted Lamp Each


#10-71901 Standard, Small, Prefocused Lamp 5/Pkg

#10-71906 Standard, Large, Frosted Lamp Each


#10-71902 Standard, Large, Prefocused Lamp 5/Pkg

The Ultralite Laryngoscope Lamp


Upgrade your present conventional laryngoscope to give a brighter light at greater economy
than the fiber optic instrument. Produces a white, bright light up to 2-1/2 times the illumination
of conventional lamps. Fits most laryngoscope blades. Made in U.S.A.

#DX-6000 Ultralamp, small (6/pkg) #DX-6000X Ultralamp, large (6/pkg)

For Propper Instruments Fiber Optic Lamps


Propper Mercury Upsher® #10-19080
Number Number (Black Insulator)

Penlon #13-0301015 5/pk


#199126 #10-71975 (Round Handle)

Upsher #10-20080
(White Insulator)

For Foregger Instruments Mercury #10-77301


2001 Fiberlight®
Foregger Mercury
Number Number Rusch #12-005630 6/pk
Focs
#454003 #10-71907 Mercury
#454004 #10-71906 Green System #10-71979

29
LARYNGOSCOPE ACCESSORIES
Magnetic Imaging Double Stick™ Martin Type Wenger Chest Infant Chest Pieces
Chest Piece Adhesive Discs
(Plastic) Chest Piece Pieces Lightweight
#10-73015 Child,
(1-1/8” diameter)
#19-00441 Martin #10-73016 Adult,
type of lightweight (1-1/2” diameter)
#19-00541 Premature aluminum
#19-00542 Child accommodates These are solid chest pieces made from
#4511-2181 Double #10-73003 Newborn,
standard plastic I.V. Stainless Steel. They have relatively
Stick Discs 612/bx (7/8” diameter)
tubing. The angle of deep sound chambers and are supplied
#12-112700 the inlet keeps the with Luer connectors for attachment to ear #10-73004 Infant,
chest piece flat. pieces. They may be placed on the sternal (1-1/8” diameter)
The Rusch Endotest is an accu- One size for notch where they may or may not be taped.
rate endotracheal tube cuff infla- premature and
Manufactured from
tor and manometer which can infant. Leather Fanny Pack lightweight, Stainless
and should be used to inflate, for Laryngoscopes Steel, infant chest
deflate and monitor the pressure Rusch Endotest
pieces feature hollow
of high volume, low pressure Cuff Pressure
design and rounded,
cuffs. Monitor
smooth chest surfaces,
making them ideal for
MERCURY 2001 FIBERLIGHT® use with newborns and
LARYNGOSCOPE BLADE SETS #10-77510 infants.

The most popular blade Leather Laryngoscope Fanny Pack with Magill Forceps
styles are now sold in sets
for your convenience. A 4 pockets and a cell phone holder.
compact, lightweight carrying
case keeps your 2001
Fiberlight Blades and acces- Gardent Tooth
sories ready for immediate Protector
use. Replace the frantic
search for misplaced blades Latex-Free
with an organized blade
system in a case.
#10-82750 Adult
Actual size: 13” x 9” x 1-3/4”
#10-81213 Disposable, #10-82760 Child
# 10-77503 The MacIntosh Set white plastic. Adult size
# 10-77504 The Miller Set comes with Mercury Medical 2001 only.
Fiberlight MacIntosh Stainless Steel #10-82770 Infant
Comes with Mercury Medical 2001 Fiberlight
Miller Stain-less Steel blades sizes, 0, 1, 2, 3, blades sizes, 0,1, 2, 3 and 4, a
and 4. Also includes a waterproof standard waterproof standard handle, a
handle, a wateproof penlight handle, a lamp waterproof penlight handle, a lamp
and a lamp key. and a lamp key.

LARYNGOSCOPE
CARRYING CASE

#10-74000 Custom Laryngoscope


Carrying Case available with your
order of laryngoscope blades LATEX-FREE HEAD HARNESS
and/or handles. Case is made of
sturdy polyethylene and can
accommodate up to four pieces. Head Harness of black, conductive rubber. Large holes
Configurable with diced foam.
permit ventilation and equal distribution of pressure over
larger areas.
Features: Part # Description
1.Conveniently fits in anesthesia machine cart
drawers.
#10-80259 Infant Head Harness
2. Organizes and protects blades and handles. #10-80255 Child Head Harness
3. Easy access. #10-80254 Adult Head Harness

#10-74005 Mercury Medical’s


own Custom Tri-Fold Case
featuring 9 clear, zippered pockets

30
ACCESSORIES

Mercury
Medical ® The
Introduces . . . Light Assists in checking and verifying
the light quality of:
Intensity
Meter • Laryngoscope Blades
(Standard Bulb and Fiber Optic)

• Fiber Optic Bronchoscopes


LIM
• Uses no Batteries

• Easy-to-Use

• Provides a relative scale for


When Ordering, individual determination of
Refer to light intensity for comparative
Part #BX-PMI-LIM-01 purposes

#53-9-0210-00 25/Box

Protect your patient’s eyes during general anesthesia against corneal


abrasion, lacerations and scleral hemorrhage. Rigid, clear plastic
protective covers are supplied with a non-allergic, self-adhesive foam
cushion for fast and accurate application.

Adult - Sterile - Single Patient Use

#10-77510
Leather Laryngoscope
Fanny Pack with 4 Pockets
and a Cell Phone Holder

#10-81401
Tube Tree

31
STYLETTES

Stylettes

The Orotracheal and Nasotracheal Illuminated Intubation Stylette


assists in the visualization required for the proper placement of
endotracheal tubes. By using the lighted stylette, the user is assured
of the correct placement of the endotracheal tube when a bright glow
in the midline of the laryngeal prominence is seen.

The pediatric Illuminated Stylette will fit comfortably into a 4.5 intubation
tube, and with lubrication into a 4.0 tube.

Benefits:
• Aids in the proper placement of endotracheal tubes
• Effectively illuminates the soft tissues of the neck
• Provides minimal neck flexion in trauma cases.
• Aids in blind intubation.

#0020-SLOT Orotracheal Illuminated Stylette


#0020-PDOT Pediatric Illuminated Stylette

Lighted Intubation Stylettes


#19-00469 Fiber Optic Malleable Lighted Stylette, Adult
#19-00470 Fiber Optic Malleable Lighted Stylette, Pediatric

The Fiber Optic, Malleable Lighted Stylette provides illumination during


intubation and also incorporates the features of a malleable stylette. With
the benefits of fiber optics, the bulb is securely encased in the handle. Replacement Stylettes
The lighted, malleable stylette assists in the visualization required for the Min. Tube
proper placement of the tracheal tube during intubation and effectively
Part # Description Size Size
illuminates the soft tissue of the neck.
#19-004691 Adult Length 36cm 5.0mm
Uses 2 “AA” Batteries (#72-MN1500)
#19-004701 Pediatric Length 25cm 3.0mm

32
STYLETTES/INTRODUCERS

#10-73102 Aluminum stylette #10-73103 Aluminum stylette #10-73104 Infant malleable


with rounded tip with tracheal tube stop stainless steel stylette

#10-73116 Replacement stop #10-73105 Adult Malleable


Stainless Steel Stylette

#10-73101 Copper stylette #19-00499 Infant stainless #19-00479 Adjustable stop of


with suction tube steel flexible wire stylette Black Delin for use with
with adjustable stop #10-73101

Slick ® Disposable Endotracheal Stylettes

Features: Sterile
• Color-coated Part
• Plastic-coated, malleable Number Size/O.D. Length Quantity
metal core #12-502501 6F 30cm 20/Bx
• Coated for easy withdrawal #12-502503 10F 44cm 20/Bx
• Single-patient use #12-502505 12F 45cm 20/Bx
#12-502507 14F 45cm 20/Bx

BOUGIE Type Introducers - Disposable

Sterile
Features: Part
BOUGIE Type Introducers will assist in directional control of Number Size Quantity
the endotracheal tube, especially when the laryngeal opening #53-9-0212-70 15Fr x 70cm with a Coude Tip 10/Bx
is not fully visible. With markings at 10cm intervals as well as #53-9-0212-72 15Fr. x 70cm with a Straight Tip 10/Bx
25cm, the Introducer will aid in determining the depth of an
E/T tube.

Part
Number Description
Eschmann Bougie Stylette #04-153014 Introducer 15FR 60cm
Tracheal Tube (Bougie for 6.0 - Angled Tip
Introducer and Guides
11.0mm tubes) 5/Box

#04-153013 Standard Guide 15FR 70cm


(for 6.0 - 11.0mm Straight Tip
The Concord/Portex
tubes) 5/Box
Introducer and Guides
are supplied non-sterile #04-103012 Intermediate 10FR 70cm
and individually packed. Guide Straight Tip
(for 4.0 - 5.5mm 5/Box
tubes)

33
NERVE STIMULATORS

Compact Peripheral Nerve Stimulator

Features:
Model 100
Although compact in design, it offers many
functions found in much larger units such as: Model 100 Compact
• Adjustable output voltage Peripheral Nerve
• 1 pulse per 8 second Stimulator, incorporates the
• 2 pulses per second latest state-of-the-art
• Train of four (2 cycles of 2 per second) electronics with solid state
• Frequency can be selected at 50 or 100HZ circuitry to ensure trouble
• Built-in battery test free operation and
• Will accept optional leads for electrode extended battery life.
pads or needle
• Uses standard 9 volt battery
• Designed for one-hand operation #19-00-100

Switch Functions:

ON-OFF - Rotate to ON Position and to a higher number for output voltage required. 1 pulse per 8 seconds in
this mode.

2 SEC. - (top left) When depressed and held, an output of 2 pulses per second will be in operation. For a train of
four, hold for two cycles. When button is released, unit will return to 1 pulse per 8 seconds.

TET- (bottom left) When depressed and held, tetaus at 100 HZ will be the output. To change output to 50 Hz,
refer to owners manual. When button is released, unit will return to 1 pulse per 8 seconds.

Specifications:

Dimensions: 5.5” long x 1.5” wide & 1” thick


Weight: 41/2 oz. - including battery
Power Source: One 9-Volt battery
Output: Adjustable with rotating
potentiometer
Voltage: 0-450 volts (open circuit)
Pulse Width: .30 millisec
Current: 0-35 milliamp.
Output is limited
#19-00-107P #19-00-108P

Ordering Information:
Item Number Description
#19-00-109 Case - Black leatherette with zipper
#10-00-112P Safety Adapter Kit (pre- year 2000
models)
#19-00-106 Ball electrodes (set)
#19-00-107P 50” leads with alligator clips
#19-00-108P 50” leads with snaps to connect
#19-00-106 #19-00-110P
to electrode pads
#19-00-110P 50” extension leads with protected
male (shrouded) and female ends

34
NERVE STIMULATORS

MICROSTIM NERVE STIMULATOR


Features:

• The MicroStim is a complete muscle relaxant monitor that fits in the palm
of your hand.

• Its functions include twitch, tetanus, and automatic train-of-four.

• This unit, though small, still offers sufficient output to ensure supramaximal
stimulation: Output current is fully adjustable from 0 to 70 mA.

• In addition to the flash of the pulse LED, an audible indicator sounds as


each stimulus pulse is delivered, enabling direct monitoring of the
patient’s response.

• The MicroStim is delivered ready to use: instruction manual, battery,


diagnostic probe and 6-foot leads with alligator clips are included.

Item Number:

#BO - 10023 Microstim Nerve Stimulator


#BO - 100057 Safety Type Leads with Alligator Clips*

* Safety version can only be used on the following units:

MicroStim BO-10023; Updated Version

Specifications:

Modes of Operation:

Standby: A Standby Switch maintains power to the instrument without generating


stimulus pulses.
Twitch: 1 s (1 pulse/s).
Tetanus: 100 Hz (100 pulses/s).
Train of Four: Single (4 pulses/2 s).
Output Current: Adjustable from 0-70 mA.
Stimulus Pulse: Square Wave Monophasic pulses (200 - U.S. duration).
Indicators: Battery LED (green) indicates that the unit is on; it flashes when
battery voltage is low. Pulse LED (RED) flashes and audible indicator
sounds each time a stimulus pulse is generated.
Power Source: 9-V alkaline battery (access door on rear panel).
Power Consumption: Approximately 15.5mA.
Case: High-impact ABS plastic with lexan overlay on membrane
touch-switches 1.0” Hx 2.42” W x 3.88” D.
Warranty: 1 year, parts and labor.

35
AIRWAYS/Oral/Nasopharyngeal

Mercury Medical® Color-Coded And


Disposable Berman/Guedel Airways
International color-coding of the reinforced bite block provides instant identification of size.
The soft kink-resistant Guedel Airways are also engraved with the millimeter size on the flange.

Guedel Airways
Std Pack Color-Coded
10/Pkg Size Guedel Airways

#10-81250C 50mm Blue - Infant


#10-81260C 60mm Black - Child
#10-81270C 70mm White - Sm Adult
#10-81280C 80mm Green - Med Adult
#10-81290C 90mm Yellow - Lg Adult
#10-81210C 100mm Red - X-Lg Adult

Std Pack Guedel


10/Pkg Airways

#10-81250 50mm
#10-81260 60mm
#10-81270 70mm
#10-81280 80mm
#10-81290 90mm
#10-81210 100mm

Berman Airways
Std Pack Berman
10/Pkg Size Airways

#10-80040 00 40 mm
#10-80050 0 50 mm
#10-80060 1 60 mm
#10-80070 2 70 mm
#10-80080 3 80 mm
#10-80090 4 90 mm
#10-80000 5 100 mm
#10-80010 6 110 mm

New Features: Sterile, Disposable,


Latex-Free Latex-Free 10/Box
Robertazzi Nasopharyngeal * Latex-Free #53-1-5075-20 20 FR
Airways * Soft - No Damage to Nasal Passage #53-1-5075-22 22 FR
* Flexible #53-1-5075-24 24 FR
* Resists Collapse and/or Kinking #53-1-5075-26 26 FR
* Resilient #53-1-5075-28 28 FR
* Nine (9) Sizes (20 - 36 FR) #53-1-5075-30 30 FR
* Sterile #53-1-5075-32 32 FR
* Best Quality #53-1-5075-34 34 FR
* Cost-Effective #53-1-5075-36 36 FR

36
CARE AND CLEANING OF UpsherScope Ultra® Laryngoscope

The UpsherScope Ultra Laryngoscope is shipped non-sterile.


It must be cleaned and disinfected or sterilized prior to use.
Disinfecting:
1. Wash the UpsherScope Ultra Laryngoscope with a mild soap solution, (soapy water), and rinse well with clean water.
2. The UpsherScope Ultra Laryngoscope may be disinfected with a 2% glutaraldehyde, cold disinfecting solution,
following the manufacturer’s recommended procedures. After the recommended soaking time, remove the unit
from the disinfecting solution and rinse with sterile, distilled water. Wipe both ends of the optical system with a
soft, dry cloth. To assure that the unit is working properly,
inspect prior to use.
Sterilizing: DO NOT AUTOCLAVE
CAUTION: FEDERAL LAW RESTRICTS THIS DEVICE TO SALE
1. Steris Compatible BY OR ON THE ORDER OF A PHYSICIAN.

2. The UpsherScope Ultra Laryngoscope may be sterilized by Ethylene Oxide (otherwise known as ETO or gas
sterilization), or by an extended period of cold soaking.
Wrap the UpsherScope Ultra Laryngoscope for ETO sterilization according to professional practice standards.
Sterilize in a standard ETO cycle. DO NOT EXCEED 138F, (60C), and 25 PSI.
3. Aerate in a standard aerator.

Upsher PowerHandle

• The PowerHandle may be disinfected with a 2% glutaraldehyde, cold disinfecting solution following the manufacturer’s
recommended procedures.

• The PowerHandle can be wiped with 70% isopropyl alcohol.


Upsher Universal Handles
Upsher Universal Handles may be soaked in soapy water or alcohol ONLY, with the batteries in place. For autoclaving or
soaking in betadine, glutaraldehyde or any other solution, the batteries must be REMOVED. If in doubt, remove the batteries.

Mercury/Upsher Blades and Handles


The Upsher Fiber Optic Laryngoscope Blade consists of a metal body and a stainless
steel clad fiber optic light guide. A stainless steel screw fastens the light guide to the
body of the blade. Should you wish to remove the light guide for cleaning, loosen the
screw until you can remove the light guide from the blade. The light guide is composed
of several thousand glass fibers encased in a stainless steel sheath and cemented in
place with a heat-resistant epoxy glue. This construction permits sterilization by
autoclaving, immersion in alcohol, soap, betadine or glutaraldehyde. The light guide
can be sterilized by itself or when attached to the body of the blade.

If the light guide, whether attached to the blade or not, is autoclaved, it should be
allowed to cool at ambient air temperature. Sudden cooling can damage components.
NEVER submerge a hot light guide into a cool liquid, as it will cause a fracture of the
glass fibers due to thermal shock. Before autoclaving, ensure that residues such as
betadine are thoroughly rinsed away.

STERILIZATION OF BLADES: (DO NOT REMOVE BULB.) Gas steriliza- quality. Tools with nylon, bristles, or soft cloths may be used. Do
tion. No aeration is required after gas sterilization. Sterilize at 250 not use steel wool or wire brushes.
degrees F (121C) for 15 minutes or at 273 degrees F (134C) for
3-1/2 - 18 minutes. (DO NOT EXCEED.) Wrap and avoid contact CLEANING: Upsher Universal Handles may be soaked in soapy
with other instruments. Never cool suddenly but allow to cool at water or alcohol ONLY, with batteries in place. For autoclaving or
ambient air temperature. Sudden cooling can damage soaking in betadine, glutaraldehyde or any other solution, the
components. Never put the light guide through an ultrasonic batteries must be REMOVED. If in doubt, remove batteries.
cleaner. The body of the blade, with the light carrier removed,
may be put through an ultrasonic cleaner. Do not immerse the If you wish to use a cleaning solution or method which is not
light carrier in any product containing Potassium Hydroxide, such detailed here, please contact Mercury Medical to confirm that the
as Metriclean. If scrubbing of the light carrier is necessary, proposed procedure will not damage laryngoscopes or handles.
whether attached to the blade or not, abrasive tools may cause
scratching on the light guide which can lead to decreased light

37
CARE AND CLEANING OF BLADES AND HANDLES

Mercury Medical® Waterproof™ Blades and Handles


Waterproof Laryngoscope Blades and Handles can be totally immersed in liquid for disinfection and
sterilization. The use of any FDA approved disinfectant or mild soap, warranted by the manufacturer to
be suitable for use with stainless steel and chrome-plated instruments, is recommended. You may also
wipe with an alcohol-soaked cloth or use a gas sterilization procedure.

WARNING: Never subject handles and blades to ultrasonic cleaning, DISINFECTION: Only use an FDA approved disinfectant. Adhere
flash (gravity steam), or dry-heat sterilization, or iodophor- strictly to manufacturer’s instruction regarding concentration and
containing disinfectants. Autoclaving is not recommended. duration. After disinfection, rinse with distilled water and wipe dry
with a cotton cloth.
PRIOR TO CLEANING: Remove batteries and tighten caps on handles;
tighten lamp on blades. STERILIZATION: After cleaning, the components can be gas-
sterilized with ethylene oxide in conventional sterilization cycles.
CLEANING: Wash with a soft brush and soapy water. After cleaning, Wrap and avoid contact with other instruments, never cool
rinse thoroughly with demineralized water and dry. suddenly, but allow to cool at ambient air temperature. Sudden
cooling can damage components.

Mercury Medical Laryngoscope Blades and Handles


Laryngoscopes should always be considered contaminated after use and should, therefore, be
cleaned and/or sterilized between patients.

CLEANING OF HANDLES: Remove batteries and wipe outside of handle DISINFECTION OF BLADES: (DO NOT REMOVE BULB.) Wipe blades
with 70% isopropyl alcohol. with 70% isopropyl alcohol or immerse in glutaraldehyde.

CLEANING OF BLADES: (DO NOT REMOVE BULB.) Immerse blades STERILIZATION OF HANDLES: Remove batteries before autoclaving or gas
in a detergent solution and thoroughly remove all blood and sterilization. No aeration is required after gas sterilization.
secretions.
STERILIZATION OF BLADES: (DO NOT REMOVE BULB.) Gas sterilization.
CLEANING: Wash with a soft brush and soapy water. After cleaning, No aeration is required after gas sterilization. Sterilize at 250
rinse thoroughly with demineralized water and dry. degrees F (121C) for 15 minutes or at 273 degrees F (134C) for
3-1/2 - 18 minutes. (DO NOT EXCEED.) Wrap and avoid contact
DISINFECTION OF HANDLES: Remove batteries and wipe outside of with other instruments. Never cool suddenly but allow to cool at
handles with 70% isopropyl alcohol. ambient air temperature. Sudden cooling can damage components.

Mercury 2001 Fiberlight®


The Mercury 2001 Fiberlight is constructed of a metal body with stainless steel sheath enclosing the light
guide. A screw fastens the light guide to the blade. To remove the light guide, loosen the 1.5 mm hex screw
until the guide can be lifted from the blade. This screw should never be forced or removed from the blade.
The light guide can be sterilized by itself or when attached to the blade.

STERILIZATION OF 2001 FIBERLIGHT: Sterilize by autoclaving, gas or with other instruments. Never cool suddenly but allow to cool at
immersion in glutaraldehyde is recommended. If a flash autoclave ambient air temperature. Sudden cooling can damage com-
is used, allow the blade to cool at ambient air temperature. Sudden ponents. If scrubbing of the light guide becomes necessary, use
cooling can damage components. Never submerge a hot light a nylon brush or soft toothbrush. Abrasive tools and cleaners are
guide or the blade into a cold liquid, as damage may result to the not recommended.
fiber optic bundle. Alcohol or betadyne can be used to clean or
disinfect. However, ultrasonic is not recommended. The high intensity bulb is located in the base of the blade and
can be removed for examination or replacement by rotating the
STERILIZATION OF BLADE: (DO NOT REMOVE BULB.) Gas sterilization. fingergrip counterclockwise. Do not force - if resistance is felt,
No aeration is required after gas sterilization. Sterilize at 250 back thread and start over, tighten until firmly seated.
degrees F (121C) for 15 minutes or at 273 degrees F (134C) for
3-1/2 - 18 minutes. (DO NOT EXCEED.) Wrap and avoid contact Use only a Mercury #10-77301 Kryptogen bulb with this product.

38
StatCO2® and Mini StatCO2™ End Tidal CO2 Detectors

StatCO2® and Mini StatCO2™


End Tidal CO2 Detectors
The Latest Innovations for Tube Placement Verifications.

The StatCO2 and Mini StatCO2 are fast, durable colorimetric breath indicators
for visualization of exhaled CO2 to assist in verifying proper intubation.

Hyperinflation System Hyperinflation System


with Manometer and Patents # US 5,557,049 B1, with Manometer and
StatCO2® Detector # US 6,502,573 B1, # US D436,050 S Mini StatCO2™ Detector
Other Patents Pending

These new StatCO2 End Tidal CO2 Detectors can help clinicians comply with the latest American Heart
Association Guidelines 2000 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care for
tube placement verification.

According to the AHA Guidelines, “In the opinion of many experts the single most important recommendation
from the Guidelines 2000 is long overdue: emergency responders must confirm tracheal tube position by
using nonphysical examination techniques. These include ... end tidal CO2 indicators.”1

1. AHA. Part 6: Advanced Cardiovascular Life


Support: Circulation 2000, page 1-87.

CRITICAL COMPONENTS
FOR
CRITICAL CARE Mini StatCO2™ ®
StatCO2
Patent # US 6,502,573 B1 Patent #US 6,502,573 B1

39
StatCO2® and Mini StatCO2™ End Tidal CO2 Detectors
StatCO2 and Mini StatCo2 are designed to connect between an endotracheal tube and a breathing device.
The patient’s exhalation gas is led through the indicator to detect approximate ranges of end tidal CO2 by color
comparison assisting in the verification of proper tube placement.

Features and Benefits: StatCO2


Indicating
StatCO2
Indicating
No Carbon Dioxide Carbon Dioxide
is Present is Present
• Long Shelf Life
(up to 2 years)

• Rapid Breath-to-Breath
Color Change (up to 24 hours)

• Convenient Pull Tab -


once removed, it activates
the device.

• Functions at Relative
Humidity (RH)
up to 100%
Mini StatCO2 Mini StatCO2
Indicating Indicating
• Detects up to 50 Breaths No Carbon Dioxide Carbon Dioxide
per Minute is Present is Present

• Cost-Effective
• Single Patient Use

• StatCO2 - For patients with body


weight greater than 15 Kg.

• Mini StatCO2 - For patients with body


weight between 1 - 15 Kg.

ORDERING INFORMATION
INDICATOR COLOR: INDICATES:
Item # Description Packaged
Blue No CO2 #10-55370 StatCO2 20/Box
is present End-Tidal CO2 Detector
Green Between 1% - 2% CO2 (For patient body weight greater than 15 Kg.)
is present
#10-55371 Mini StatCO2 20/Box
Yellow 5% or more CO2 is present End Tidal CO2 Detector
(For patient body weight between 1 and 15 Kg.)
Permanent Yellow or White Color A damaged indicator

Mechanical Specifications:
StatCO2
Internal Volume: 25 cc Connector Ports:
Resistance to Flow: 3.0 cm H2O Patient end: 15 mm I.D.
nominal at 60 L/min flow Circuit end: 15 mm O.D.
Weight: 22 grams nominal
Mini StatCO2 Patient end: 18 mm nominal non-standard
Internal Volume: 3 cc O.D./15 mm I.D.
Resistance to Flow: 2.5 cm H2O Circuit end: 15 mm O.D. standard taper/I.D.
nominal at 10/min flow non-standard 6 mm nominal
Weight: 5 grams nominal

40
Troop Elevation Pillow™

The Troop Elevation Pillow is an Aid to Airway


Management for morbidly obese patients. The

An Aid
single patient use pillow is for intra-op and post-op
care. It is a solid foam positioner intended to facilitate
airway management for obese and large-framed
patients.

to Airway Designed and developed by a practicing physician,


the Elevation Pillow addresses the inherent problem

Management
of “stacking blankets.” The Elevation Pillow is stable
and easy to set-up. The pillow quickly achieves the
“head-elevated laryngoscopy position, (HELP).” This
position is recommended for airway management of

for Obese Patients.


obese patients.

For additional information on the Troop Elevation


Pillow, please call:

800-835-6633 • 800-237-6418

800-237-6418

The Troop Elevation Pillow™


raises (isolates) the head and neck (upper airway)
above the patient’s chest and abdomen.

Elevation Pillow shown with Standard


Intubating Pillow. “Proper positioning of the
morbidly obese patient is essential to facilitate
Airway Management during surgery.”

Patent # US 6,751,818 B2

A head-elevating laryngoscopy positioner


for Airway Management
in morbidly obese and large-framed patients.

Replace a pile of unstable blankets (“stacking”)


and improve “ease of breathing”
for your obese patients.

41
Troop Elevation Pillow™

Benefits: Indications for Use:


• Aids Airway Management for obese patients. • General and Regional Anesthesia for obese
patients.
• Improves “Ease of Breathing.”
• Local Anesthesia with I.V. Sedation for
• Helps align the Upper Airway Axes. obese patients.

• Aid to improve mask and spontaneous


• Obese patients breathe more comfortably during
ventilation.
pre-oxygenation (pre-induction).
• Obstetric C-Section cases.
• The Elevation Pillow greatly facilitates mask ventilation.
• ENT, Head & Neck, Facial Surgeries.
• Easier, faster set-up eliminating “stacking of blankets.”
• Neurosurgery; positioning aid for Anterior
Cervical Fusion.
• Stable patient positioning is maintained during surgery.
• Bariatric Surgery.
• Helps decrease Acid Reflux (aid to manage GERD).
• X-Ray/Cath Lab Procedures.

Latex Free
Anti-Static

Ordering Information:

#10-910-00 Troop Elevation Pillow™ 4/Box


#96-8815 Head Cradle, Adult 24/Box

Patent # US 6,751,818 B2
Latex

Troop Elevation Pillow shown with Head Cradle

42
WARRANTY INFORMATION

WARRANTY
Limitation of Liability. For a period of one (1) year from the date of shipment tured by others, the Seller will only make available for the Buyer’s benefit
of Seller’s products hereunder, Seller warrants that, except for rubber, plastic, those warranties which Seller has received from third party manufacturers.
or other similar materials, at the time of shipment the products conform to the Any authorization of Seller for repair or alteration by the Buyer must be in
description on the face of the shipper. SELLER MAKES NO OTHER WAR- writing to prevent voiding this warranty.
RANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, IN FACT OR SELLER SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT OR CONSE-
BY LAW, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MER- QUENTIAL DAMAGES, NOR BE LIABLE FOR DAMAGES OF ANY KIND
CHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The liabil- ARISING FROM THE PRESENCE OR USE OF ANY OF SELLER’S PROD-
ity for product covered by this warranty is limited solely to replacing, repairing, UCTS, WHETHER USED SINGLY OR IN COMBINATION WITH OTHER
or issuing credit for, at the discretion of Seller, the parts that are found during PRODUCTS OR SUBSTANCES. Determination of the suitability of any of
the period to have been damaged or defective upon shipment, provided that Seller’s products furnished hereunder for the use contemplated by Buyer is
Seller will not be liable under this warranty unless (i) Seller is promptly noti- the sole responsibility of Buyer and Seller shall have no responsibility in con-
fied in writing by Buyer upon discovery of such damage or defect; (ii) the nection therewith. Buyer assumes all risk and liability for loss, damage or
defective unit or part is returned to Seller, transportation charges prepaid by injury to persons or property of Buyer or others arising out of the use or pos-
Buyer and (iii) Seller’s examination of such unit or part shall disclose to its session of Seller’s products. The warranty as hereinabove set forth shall not
satisfaction that such defects or failures have not been caused by misuse, be enlarged, diminished or affected by, and no obligation or liability shall arise
neglect, improper installation, unauthorized repair or alteration or accident. If to grow out of the renderings of technical advice or service in connection with
the equipment manufactured by Seller consists primarily of parts manufac- Buyer’s order or the products furnished hereunder.

43
NOTES

44
NOTES

45