Analog Sensor Interfacing
Sensor Interfacing and Signal
Conditioning
Transducer
Transducer convert physical data such as
temperature, light intensity, flow and speed to
electrical signals electrical signals.
Depending on the transducer, the output produced
is in the form of voltage, current, resistance or
capacitance.
Signal Conditioning
In order to send input to an A-to-D converter,
the transducer output in the form of voltage,
current, charge, capacitance or resistance should
b t d t f f lt
2
be converted to form of voltage.
This conversion (modification) is commonly
called as Signal Conditioning.
Signal conditioning can be current-voltage
conversion or signal amplification.
Getting data from Analog World
Mohd
Fadzil
Digitally signed by Mohd
Fadzil
DN: cn=Mohd Fadzil, o, ou,
email=fdzl_hssn@yahoo.fr,
c=MY
Date: 2013.03.15 12:33:27
+08'00'
2
Sensor Interfacing and Signal
Conditioning
Temperature Sensor: LM35 Series
The sensors of the LM35 series are precision integrated-circuit
temperature sensors whose output voltage is linearly
ti l t th C l i t t proportional to the Celsius temperature.
Requires no external calibration because it is internally
calibrated.
It outputs 10 mV for each degree of Celsius temperature.
If we use the internal 2.56 V reference voltage, the step size
would be 2.56V / 1024 =2.5mV
This binary output number for the ADC four times the real
3
temperature because the sensor produces 10 mV for each degree
of temperature change and the step size is 2.5 mV (10 mV/2.5 mV
= 4).
Thus, we can scale it by dividing it by 4 to get real number of
temperature.
Sensor Interfacing and Signal
Conditioning
Temperature (F) Vs Vout for AVR with Vref = 2.56 V LM34/35 Connection to AVR and its Pin
4
p ( ) 3 /35 Co ect o to a d ts
Configuration
3
Characteristics of the ADC
1) Draw the circuit in Proteus and write a program to read
analog data (e g temperature) and displaying the data using analog data (e.g temperature) and displaying the data using
8 LEDs.The following pints must be noted:
The analog temperature device is represented by using
variable resistor and connected to channel 0.
The 8 LEDs connected to PORT B of AVR.
The 10-bit output of A/D is divided by 4 to get real
5
temperature.
To divide the 10-bit output of A/D by 4, choose the left-
justified option and only read ADCH register.
Remark: You are recommended to simulate your program in
Proteus
Characteristics of the ADC
2)By referring the Table: Temperature (F) Vs Vout for AVR
withVref = 2.56V
Verify the AVR output for a temperature of 70 degrees
Fahrenheit. Find values in the AVR A/D registers of ADCH
and ADCL for left-justified.