Está en la página 1de 96

Halogen free & Mud resistant Offshore cable

NEK-606(2009) | IEC 60092-350, 353, 354, 376

TMC Co., Ltd has been pursuing innovation in technology


and products for marine, oil and gas industry.
For 20 years TMC has had a single-minded focus on delivering superior
customer services with specialized marine and offshore cable solutions.
The operational excellence of TMC is underpinned by its products with the best
quality and the flexibility to meet specific requirements that makes us the world's
most experienced marine and offshore cable manufacturer.

Company History
1991 Establishment of Seojin Industry Co.,Ltd.

1998 ISO 9001 Certification by LRQA (Quality)

2004 ISO 14001 Certification by LRQA (Environment & Quality)


2005 Changed the name of company to TMC Co.,Ltd.

2006 Won the 30 million USD Export Tower Award granted by the Ministry of Knowledge Economy
2006 Earned recognition by Hyundai Mipo Dockyard Co., Ltd. as one of the excellent suppliers.

2007 Won the 70 million USD Export Tower Award granted by the Ministry of Knowledge Economy
2007 Received the High quality supplier Certification from DSME
2007 Achieved Korean world-class product award 2007

2008 Won the 100 million USD Export Tower Award granted by the Ministry of Knowledge Economy
2008 OHSAS 18001 Certification by LRQA (for Health, Safety and Environment)

2009 Awarded the Q-Mark as a Silver grade for Offshore Cable supplier by Samsung Heavy Industries
2010 Awarded the Best Supplier for Offshore & Marine Cable by Ocean Rig
2010 Earned recognition by DSME as one of the excellent supplier
2011
2011

Awarded the Best Supplier for Offshore & Marine Cable by Stena Sphere
KEPIC Certification by KEA (Manufacture of Class 1E cable)

2012 Won the 200 million USD Export Tower Award granted by the Ministry of Knowledge Economy

Certificates
Type Approval Certification for shipboard cables : ABS, BV, CCS, DNV, GL, KR, LR, NK and RINA
Type Approval Certification for NEK 606(2004) offshore cables : ABS, DNV and LR
Type Approval Certification by ABS for offshore cables and listed on ETL
Type Approval Certification for Passenger ships cables : ABS, DNV,LR, BV and CCS
Obtained Patent of Paint Resistant Shipboard Cables (Patent N0. 10-0627241)
Type Approval Certification for IEEE1580 Type P cables : ABS and DNV and listed on ETL
Type Approval Certification for LNG Carrier cables : ABS, DNV, LR and BV
Gost-R Certification for NEK 606(2004) offshore cables by GOSSTANDART
Type Approval Certification for Marine Optical Fiber Cables : ABS and DNV

TOTAL SOLUTION OF MARINE CABLE

Halogen free & Mud resistant Offshore cable

Code Designation
Materials

Insulation

Fire resistance tape+insulation (Halogen-free)

Halogen-free ethylene propylene rubber - HF EPR

Cross-linked polyethylene XLPE

Thermoplastic compound (Halogen-free)

Halogen-free thermoset compound or EVA

Bedding / inner
covering inner sheath

Bedding/Inner covering or taping (Halogen-free)

Screen (poss. with PE or PP)

Armor / screen

No armour

Copper wire braid (Tinned or bare)

Bronze wire braid

Galvanized steel wire braid

Outer sheath

Thermoplastic compound (Halogen-free) SHF1

Halogen-free thermoset compound, SHF2

Halogen-free mud resistant thermoset


compound, SHF Mud

Halogen-free mud resistant thermoset compound

Note. QFCB cables only

Added abbreviation
(i)

Individual screen

(c)

Collective screen

( i&c)

Individual & Collevtive screen

Example

0.6/1kV BFOU
Voltage
Fire resisting layer + insulation(HF EPR)
Inner covering(HFC)
Armor(Copper)
Sheath(SHF2 or SHF mud)

Index

NEK 606 Cable type code


Materials

Designation

Page

3.6/6kV RFOU, RFBU


HV power cable

Flame retardant

6/10kV RFOU, RFBU

06 ~ 09

8.7/15kV RFOU, RFBU


LV power &
lighting cable

Flame retardant
Fire resistance

Flame retardant
Instrumentation &
Communication cable

Earthing & Bonding wire


VFD cable
Technical information

Cable type code


H/F
H/F & M/R

3.6/6kV RFOU

P2

P2/P9

6/10kV RFOU

P3

P3/P10
P4/P11

0.6/1kV RU

11 ~ 14

8.7/15kV RFOU

P4

0.6/1kV RFOU, RFCU, RFBU

15 ~ 18

0.6/1kV RFOU

P1

P1/P8

0.6/1kV BU

19 ~ 22

0.6/1kV BFOU

P5

P5/P12

0.6/1kV BFOU, BFCU, BFBU

23 ~ 26

0.6/1kV RU

P18

250V RU(c), RU(i), RU(i&c)

28 ~ 36

0.6/1kV BU

P17

37 ~ 39

0.6/1kV UX

P15

250V RFOU(i), RFCU(i), RFBU(i)

40 ~ 42

250V RFOU(i)

S1

S1/S5

250V RFOU(i&c), RFCU(i&c), RFBU(i&c)

43 ~ 45

250V RFOU(c)

S2

S2/S6

46 ~ 54

250V BFOU(i)

S3

S3/S7

55 ~ 57

250V BFOU(c)

S4

S4/S8

58 ~ 60

250V RU(i)

S11

S12

250V RFOU(c), RFCU(c), RFBU(c)

250V BU(c), BU(i), BU(i&c)


Fire resistance

Designation

250V BFOU(c) , BFCU(c) , BFBU(c)


250V BFOU(i) , BFCU(i), BFBU(i)

250V BFOU(i&c), BFCU(i&c), BFBU(i&c)

61 ~ 63

250V RU(c)

Flame retardant

0.6/1kV UX, FX-UX, RX

65 ~ 66

250V BU(i)

S13

Flame retardant

0.6/1kV(1.8/3kV) RFOU(VFD), FX-RFOU(VFD)

68 ~ 69

250V BU(c)

S14

Fire resistance

0.6/1kV(1.8/3kV) BFOU(VFD), FX-BFOU(VFD)

70 ~ 71

Note.

73 ~ 93

- H/F :Halogen free cable


- H/F & M/R : Halogen free & Mud resistant cable

HV Power Cable

3.6/6kV RFOU, RFBU


6/10kV RFOU, RFBU
8.7/15kV RFOU, RFBU

06 ~ 09

Halogen free & Mud resistant Offshore cable

HV Power Cable

Cable Designation (P2, P3, P4, P2/P9, P3/P10, P4/P11)


3.6/6kV RFOU, RFBU
6/10kV RFOU, RFBU
8.7/15kV RFOU, RFBU

Application Standard
- Design guide

: NEK-606 & IEC 60092-354

- Flame retardant

: IEC 60332-1 &

6/10kV RFOU

IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Construction
Sectional view

Classification

Code

Construction detail

Conductor

- Stranded tinned annealed copper wires as per IEC 60228, Class 2

Conductor screen

- Semi-conducting layer (tape / compound)

Insulation

- HF EPR as per IEC 60092-351


- Non-metallic part : Semi-conducting layer (tape / compound)

Insulation screen

- Metallic part : Copper wire braid


- A suitable separator tape(s) may be applied over the metallic part
- Three metallic braided conductors shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core


- A Filler may be applied to obtain a circular Cable

Inner covering
Armor
Sheath
Core identification
Note. Flexible cable (Class5 Conductor) can be supplied

06

Offshore Cable

- Flame retardant halogen free thermoset compound

- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)

(B,C)
U

- A suitable separator tape(s) may be applied under/over the armor


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Red
- 3C : Off-white, Black, Red

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

EA

mm

mm

Dia of Thickness Nominal


copper
of
dia.
wire
inner
inner
for braid covering covering
mm

mm

mm

Dia. of
wire for
armour
mm

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

mm

Conductor
Resistance
(at 20)
(Max.)

Test
Voltage

Cable
Weight

mm

/km

V/5min.

kg/km

10

4.2

2.5

0.3

1.0

15.7

0.3

1.5

21.0

1.1

1.840

12.5

740

16

5.3

2.5

0.3

1.0

16.7

0.3

1.6

22.2

1.2

1.160

12.5

850

25

6.6

2.5

0.3

1.0

18.0

0.3

1.6

23.5

1.2

0.734

12.5

1,000

35

7.9

2.5

0.3

1.0

19.2

0.3

1.7

24.9

1.3

0.529

12.5

1,160

50

19

9.1

2.5

0.3

1.0

20.5

0.3

1.7

26.2

1.3

0.391

12.5

1,340

70

19

11.0

2.5

0.3

1.0

22.3

0.3

1.8

28.2

1.4

0.270

12.5

1,630

95

19

12.9

2.5

0.3

1.0

24.2

0.3

1.9

30.3

1.5

0.195

12.5

1,980

120

37

14.5

2.5

0.3

1.0

25.8

0.3

1.9

31.9

1.6

0.154

12.5

2,290

150

37

16.2

2.5

0.3

1.2

27.8

0.3

2.0

34.1

1.7

0.126

12.5

2,680

185

37

18.0

2.5

0.3

1.2

29.6

0.3

2.1

36.1

1.7

0.100

12.5

3,130

240

61

20.6

2.6

0.3

1.2

32.5

0.4

2.2

39.7

1.9

0.0762

12.5

3,940

300

61

23.1

2.8

0.4

1.2

35.7

0.4

2.3

43.1

2.0

0.0607

12.5

4,800

400

61

26.1

3.0

0.4

1.4

39.9

0.4

2.5

47.7

2.2

0.0475

12.5

6,050

500

61

29.2

3.2

0.4

1.4

43.0

0.4

2.6

51.0

2.3

0.0369

12.5

7,090

630

91

33.2

3.2

0.4

1.4

47.2

0.4

2.8

55.6

2.5

0.0286

12.5

8,810

10

4.2

2.5

0.3

1.2

31.9

0.4

2.2

39.1

1.9

1.840

12.5

2,360

16

5.3

2.5

0.3

1.2

34.1

0.4

2.3

41.5

2.0

1.160

12.5

2,740

25

6.6

2.5

0.3

1.2

36.9

0.4

2.4

44.5

2.1

0.734

12.5

3,280

35

7.9

2.5

0.3

1.4

39.9

0.4

2.5

47.7

2.2

0.529

12.5

3,860

50

19

9.1

2.5

0.3

1.4

42.7

0.4

2.6

50.7

2.3

0.391

12.5

4,500

70

19

11.0

2.5

0.3

1.4

46.5

0.4

2.8

54.9

2.5

0.270

12.5

5,520
6,770

95

19

12.9

2.5

0.3

1.6

51.0

0.4

2.9

59.6

2.7

0.195

12.5

120

37

14.5

2.5

0.3

1.6

54.5

0.4

3.1

63.5

2.8

0.154

12.5

7,910

150

37

16.2

2.5

0.3

1.6

57.9

0.4

3.2

67.1

3.0

0.126

12.5

9,080

185

37

18.0

2.5

0.3

1.6

61.8

0.4

3.4

71.4

3.2

0.100

12.5

10,630

240

61

20.6

2.6

0.3

1.8

68.5

0.4

3.6

78.5

3.4

0.0762

12.5

13,190

0.3

1.2

36.9

0.4

2.4

44.5

2.1

0.734

12.5

3,460

0.3

1.4

40.5

0.4

2.5

48.3

2.2

0.529

12.5

4,180

0.3

1.4

43.0

0.4

2.6

51.0

2.3

0.391

12.5

4,800

0.3

1.4

47.0

0.4

2.8

55.4

2.5

0.270

12.5

5,930

0.3

1.6

51.8

0.4

3.0

60.6

2.7

0.195

12.5

7,350

0.3

1.6

55.8

0.4

3.1

64.8

2.9

0.154

12.5

8,710

0.3

1.6

59.8

0.4

3.3

69.2

3.1

0.126

12.5

10,220

0.3

1.8

63.8

0.4

3.5

73.6

3.2

0.100

12.5

11,830

0.3

1.8

70.1

0.4

3.7

80.3

3.5

0.0762

12.5

14,540

2C

25

6.6

2.5

Earth

16

5.3

1.0

2C

35

7.9

2.5

Earth

25

6.6

1.2

2C

50

19

9.1

2.5

Earth

25

6.6

1.2

2C

70

19

11.0

2.5

Earth

35

7.9

1.2

2C

95

19

12.9

2.5

Earth

50

19

9.1

1.4

2C

120

37

14.5

2.5

Earth

70

19

11.0

1.4

2C

150

37

16.2

2.5

Earth

95

19

12.9

1.6

2C

185

37

18.0

2.5

Earth

95

19

12.9

1.6

2C

240

61

20.6

2.6

Earth

120

37

14.5

1.6

Offshore Cable

LV Power & Lighting Cable

mm2

Thickness
of
Insulation

Instrumentation &
Communication Cable

Max.
overall
dia.

Earthing & Bonding wire

Min.
No. of
wires

VFD Cable

No.

Conductor
Nominal
Area

Technical Information

No. of
Cores

HV Power Cable

3.6/6kV RFOU, 3.6/6kV RFBU

07

Halogen free & Mud resistant Offshore cable

HV Power Cable
6/10kV RFOU, 6/10kV RFBU
No. of
Cores

No.

Conductor
Nominal
Area

Min.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

Thickness
of
Insulation

Dia of
copper
wire
for braid

Thickness
of
inner
covering

Nominal
dia.
inner
covering

Dia. of
wire for
armour

Thickness
of
sheath

mm

mm

mm

mm

mm

mm

Overall diameter
Nominal

Tolerance

mm

mm

Conductor
Resistance
(at 20)
(Max.)

Test
Voltage

Cable
Weight

/km

V/5min.

kg/km

16

5.3

3.4

0.3

1.0

18.5

0.3

1.6

24.0

1.3

1.160

21.0

960

25

6.6

3.4

0.3

1.0

19.8

0.3

1.7

25.5

1.3

0.734

21.0

1,130

35

7.9

3.4

0.3

1.0

21.0

0.3

1.7

26.7

1.4

0.529

21.0

1,280

50

19

9.1

3.4

0.3

1.0

22.3

0.3

1.8

28.2

1.4

0.391

21.0

1,480

70

19

11.0

3.4

0.3

1.0

24.1

0.3

1.8

30.0

1.5

0.270

21.0

1,770

95

19

12.9

3.4

0.3

1.0

26.0

0.3

1.9

32.1

1.6

0.195

21.0

2,130

120

37

14.5

3.4

0.3

1.2

28.0

0.3

2.0

34.3

1.7

0.154

21.0

2,500

150

37

16.2

3.4

0.3

1.2

29.6

0.3

2.1

36.1

1.7

0.126

21.0

2,860

185

37

18.0

3.4

0.3

1.2

31.4

0.4

2.2

38.6

1.8

0.100

21.0

3,410

240

61

20.6

3.4

0.4

1.2

34.5

0.4

2.3

41.9

2.0

0.0762

21.0

4,220

300

61

23.1

3.4

0.4

1.2

36.9

0.4

2.4

44.5

2.1

0.0607

21.0

4,960

400

61

26.1

3.4

0.4

1.4

40.7

0.4

2.5

48.5

2.2

0.0475

21.0

6,140

500

61

29.2

3.4

0.4

1.4

43.4

0.4

2.6

51.4

2.4

0.0369

21.0

7,140

630

91

33.2

3.4

0.4

1.4

47.6

0.4

2.8

56.0

2.5

0.0286

21.0

8,870

16

5.3

3.4

0.3

1.4

38.4

0.4

2.4

46.0

2.1

1.160

21.0

3,230

25

6.6

3.4

0.3

1.4

41.2

0.4

2.6

49.2

2.3

0.734

21.0

3,820

35

7.9

3.4

0.3

1.4

43.7

0.4

2.7

51.9

2.4

0.529

21.0

4,370

50

19

9.1

3.4

0.3

1.4

46.5

0.4

2.8

54.9

2.5

0.391

21.0

5,040

70

19

11.0

3.4

0.3

1.6

50.8

0.4

2.9

59.4

2.7

0.270

21.0

6,140

95

19

12.9

3.4

0.3

1.6

54.9

0.4

3.1

63.9

2.9

0.195

21.0

7,400

120

37

14.5

3.4

0.3

1.6

58.4

0.4

3.2

67.6

3.0

0.154

21.0

8,540

150

37

16.2

3.4

0.3

1.6

61.8

0.4

3.4

71.4

3.2

0.126

21.0

9,780

185

37

18.0

3.4

0.3

1.8

66.1

0.4

3.5

75.9

3.3

0.100

21.0

11,410

240

61

20.6

3.4

0.4

1.8

72.8

0.4

3.8

83.2

3.6

0.0762

21.0

14,240

2C

25

6.6

3.4

0.3

1.4

41.2

0.4

2.6

49.2

2.3

0.734

21.0

4,020

Earth

16

5.3

1.0

2C

35

7.9

3.4

0.3

1.4

44.0

0.4

2.7

52.2

2.4

0.529

21.0

4,680

0.3

1.4

46.5

0.4

2.8

54.9

2.5

0.391

21.0

5,320

0.3

1.6

50.9

0.4

2.9

59.5

2.7

0.270

21.0

6,520

0.3

1.6

55.4

0.4

3.1

64.4

2.9

0.195

21.0

7,940

0.3

1.6

59.2

0.4

3.3

68.6

3.0

0.154

21.0

9,340

0.3

1.8

63.8

0.4

3.5

73.6

3.2

0.126

21.0

10,990

0.3

1.8

67.3

0.4

3.6

77.3

3.4

0.100

21.0

12,520

0.4

1.8

74.0

0.4

3.9

84.6

3.7

0.0762

21.0

15,560

Earth

25

6.6

1.2

2C

50

19

9.1

3.4

Earth

25

6.6

1.2

2C

70

19

11.0

3.4

Earth

35

7.9

1.2

2C

95

19

12.9

3.4

Earth

50

19

9.1

1.4

2C

120

37

14.5

3.4

Earth

70

19

11.0

1.4

2C

150

37

16.2

3.4

Earth

95

19

12.9

1.6

2C

185

37

18.0

3.4

Earth

95

19

12.9

1.6

2C

240

61

20.6

3.4

Earth

120

37

14.5

1.6

08

Offshore Cable

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

8.7/15kV RFOU, 8.7/15kV RFBU

mm

2C

6.6

mm

4.5

mm

0.3

mm

1.0

mm

22.0

Dia. of
wire for
armour
mm

0.3

Conductor
Resistance
(at 20)
(Max.)

Test
Voltage

mm

/km

V/5min.

kg/km

1.4

0.734

30.5

1,300

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.8

mm

27.9

Cable
Weight

35

7.9

4.5

0.3

1.0

23.2

0.3

1.8

29.1

1.5

0.529

30.5

1,460

50

19

9.1

4.5

0.3

1.0

24.5

0.3

1.9

30.6

1.5

0.391

30.5

1,660

70

19

11.0

4.5

0.3

1.0

26.3

0.3

1.9

32.4

1.6

0.270

30.5

1,960

95

19

12.9

4.5

0.3

1.2

28.6

0.3

2.0

34.9

1.7

0.195

30.5

2,370

120

37

14.5

4.5

0.3

1.2

30.2

0.4

2.1

37.2

1.8

0.154

30.5

2,810

150

37

16.2

4.5

0.3

1.2

31.8

0.4

2.2

39.0

1.9

0.126

30.5

3,180

185

37

18.0

4.5

0.3

1.2

33.6

0.4

2.2

40.8

1.9

0.100

30.5

3,630

240

61

20.6

4.5

0.4

1.2

36.7

0.4

2.4

44.3

2.1

0.0762

30.5

4,490

300

61

23.1

4.5

0.4

1.4

39.5

0.4

2.5

47.3

2.2

0.0607

30.5

5,290

400

61

26.1

4.5

0.4

1.4

42.9

0.4

2.6

50.9

2.3

0.0475

30.5

6,450

500

61

29.2

4.5

0.4

1.4

45.6

0.4

2.7

53.8

2.5

0.0369

30.5

7,460

630

91

33.2

4.5

0.4

1.6

50.2

0.4

2.9

58.8

2.7

0.0286

30.5

9,270

25

6.6

4.5

0.3

1.4

45.9

0.4

2.7

54.1

2.5

0.734

30.5

4,430

35

7.9

4.5

0.3

1.6

48.9

0.4

2.9

57.5

2.6

0.529

30.5

5,110

50

19

9.1

4.5

0.3

1.6

51.7

0.4

3.0

60.5

2.7

0.391

30.5

5,810

70

19

11.0

4.5

0.3

1.6

55.6

0.4

3.1

64.6

2.9

0.270

30.5

6,900

95

19

12.9

4.5

0.3

1.6

59.7

0.4

3.3

69.1

3.1

0.195

30.5

8,210

120

37

14.5

4.5

0.3

1.6

63.1

0.4

3.4

72.7

3.2

0.154

30.5

9,380

150

37

16.2

4.5

0.3

1.8

67.0

0.4

3.6

77.0

3.4

0.126

30.5

10,750

185

37

18.0

4.5

0.3

1.8

70.8

0.4

3.7

81.0

3.5

0.100

30.5

12,330

240

61

20.6

4.5

0.4

1.8

77.5

0.4

4.0

88.3

3.8

0.0762

30.5

15,260

25

6.6

4.5

0.3

1.4

45.9

0.4

2.7

54.1

2.5

0.734

30.5

4,670

0.3

1.6

48.9

0.4

2.9

57.5

2.6

0.529

30.5

5,420

0.3

1.6

51.7

0.4

3.0

60.5

2.7

0.391

30.5

6,140

0.3

1.6

55.6

0.4

3.1

64.6

2.9

0.270

30.5

7,320

0.3

1.6

59.7

0.4

3.3

69.1

3.1

0.195

30.5

8,730

0.3

1.8

63.9

0.4

3.5

73.7

3.2

0.154

30.5

10,250

0.3

1.8

68.0

0.4

3.6

78.0

3.4

0.126

30.5

11,830

0.3

1.8

71.5

0.4

3.8

81.9

3.6

0.100

30.5

13,430

0.4

1.8

78.3

0.4

4.0

89.1

3.9

0.0762

30.5

16,540

Earth

16

5.3

1.0

2C

35

7.9

4.5

Earth

25

6.6

1.2

2C

50

19

9.1

4.5

Earth

25

6.6

1.2

2C

70

19

11.0

4.5

Earth

35

7.9

1.2

2C

95

19

12.9

4.5

Earth

50

19

9.1

1.4

2C

120

37

14.5

4.5

Earth

70

19

11.0

1.4

2C

150

37

16.2

4.5

Earth

95

19

12.9

1.6

2C

185

37

18.0

4.5

Earth

95

19

12.9

1.6

2C

240

61

20.6

4.5

Earth

120

37

14.5

1.6

HV Power Cable

EA

25

Dia of Thickness Nominal


copper
of
dia.
wire
inner
inner
for braid covering covering

LV Power & Lighting Cable

mm2

Thickness
of
Insulation

Instrumentation &
Communication Cable

Max.
overall
dia.

Earthing & Bonding wire

Min.
No. of
wires

VFD Cable

No.

Conductor
Nominal
Area

Technical Information

No. of
Cores

Offshore Cable

09

LV Power & Lighting Cable

0.6/1kV RU

11 ~ 14

0.6/1kV RFOU, RFCU, RFBU

15 ~ 18

0.6/1kV BU

19 ~ 22

0.6/1kV BFOU, BFCU, BFBU

23 ~ 26

LV Power & Lighting Cable

LV Power & Lighting Cable

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Cable Designation (P18)


LV Power & Lighting Cable

0.6/1kV RU

Application Standard
- Design guide

: NEK-606 & IEC 60092-353

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

0.6/1kV RU

Sectional view

Classification

Code

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

Conductor
Insulation

Earthing & Bonding wire

Construction
R

- HF EPR as per IEC 60092-351


- Insulated cores shall be cabled

Cabling

- Flame retardant & non-hygroscopic fillers may be used


- Suitable tape(s) may be applied on the cabled core
- A Filler may be applied to obtain a circular Cable
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Black
No. of cores

Core identification

Without Earth core

VFD Cable

With Earth core

1C

Off-white or Black

2C

Off-white, Black

3C / 2C + E

Off-white, Black, Red

Off-white, Black, G/Y

4C / 3C + E

Off-white, Black, Red, Blue

Off-white, Black, Red, G/Y

5C / 4C + E

Black No. on white insulation

Off-white, Black, Red, Blue, G/Y

6C and over

Black No. on white insulation

Black No. on white insulation, G/Y

Technical Information

Sheath

Note. 1. Flexible cable (Class5 Conductor) can be supplied

2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)

Offshore Cable

11

Halogen free & Mud resistant Offshore cable

LV Power & Lighting Cable


0.6/1kV RU
No. of
Cores

No.

2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth

12

Conductor
Nominal
Area

Min.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Offshore Cable

7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37

1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5

Thickness
of
Insulation

Thickness
of
sheath

mm

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

Overall diameter
Nominal

Tolerance

mm

mm

1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.1
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.7
1.9
2.0
2.2
2.3
2.5
2.8
3.0
1.1
1.1
1.2
1.2
1.3
1.4
1.5

5.8
6.2
6.7
7.3
8.2
9.4
11.1
12.4
14.4
16.1
18.6
20.3
22.4
25.1
28.3
31.5
9.6
10.4
11.6
12.8
14.8
17.0
20.6
23.0
26.8
30.8
35.6
39.0
43.0
48.4
55.0
61.0
10.2
11.0
12.3
13.6
15.7
18.1
21.3

0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.8
0.9
0.9
1.0
1.1
1.1
1.2
0.6
0.6
0.6
0.7
0.7
0.8
0.9
1.0
1.1
1.2
1.4
1.5
1.6
1.8
2.0
2.1
0.6
0.6
0.7
0.7
0.8
0.8
0.9

1.6

24.1

1.0

1.8

27.7

1.1

1.9

31.6

1.2

2.1

36.7

1.4

2.2

40.2

1.5

2.4

44.9

1.6

2.6

49.7

1.8

2.8

56.0

2.0

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight

/km

-km

V/5min.

kg/km

12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154

1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330

3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

60
70
90
110
160
230
340
450
600
810
1,100
1,360
1,650
2,070
2,690
3,340
140
170
230
290
390
550
840
1,090
1,450
2,000
2,690
3,300
4,000
5,030
6,550
8,090
160
210
270
360
510
730
1,000
1,360
1,730
2,350
3,190
3,970
4,970
5,980
7,660

LV Power & Lighting Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

4C+E
4C+E
4C+E
4C+E
4C+E
4C+E
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth

mm
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5

Thickness
of
sheath

mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

mm
1.1
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.8
1.9
2.1
2.3
2.4
2.7
2.9
3.2
1.1
1.2
1.2
1.3
1.4
1.5
1.6

Overall diameter
Nominal

mm
10.2
11.0
12.3
13.6
15.7
18.1
21.9
24.5
29.0
32.9
38.2
41.9
46.1
52.1
59.0
65.6
11.1
12.3
13.5
15.1
17.5
20.1
23.8

Tolerance
mm
0.6
0.6
0.7
0.7
0.8
0.8
1.0
1.0
1.2
1.3
1.4
1.6
1.7
1.9
2.1
2.3
0.6
0.7
0.7
0.8
0.8
0.9
1.0

1.7

26.9

1.1

1.9

31.2

1.2

2.0

35.3

1.4

2.3

41.3

1.5

2.4

45.2

1.7

2.6

50.3

1.8

2.8

55.9

2.0

3.1

63.2

2.2

1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.7
1.9
2.1
2.3
2.5
2.6
2.9
3.2
3.4
1.2
1.2
1.3
1.4
1.4
1.6
1.7

11.1
12.3
13.5
15.1
17.5
20.1
24.4
27.3
32.2
36.7
42.7
46.7
51.5
58.1
65.9
73.1
12.3
13.4
15.0
16.8
19.2
22.3
26.6

0.6
0.7
0.7
0.8
0.8
0.9
1.0
1.1
1.3
1.4
1.6
1.7
1.8
2.0
2.3
2.5
0.7
0.7
0.8
0.8
0.9
1.0
1.1

1.8

30.1

1.2

2.0

34.8

1.3

2.2

39.6

1.5

2.4

46.0

1.7

2.6

50.5

1.8

2.8

56.2

2.0

3.0

62.5

2.2

3.3

70.7

2.4

Conductor
Resistance
(at 20)
(Max.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154

Insulation
Resistance
(at 20)
(Min.)
-km
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330

Test
Voltage

Cable
Weight

V/5min.
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

kg/km
160
210
270
360
510
730
1,110
1,450
1,990
2,700
3,670
4,520
5,480
6,930
8,970
11,140
200
260
340
450
650
930
1,330

LV Power & Lighting Cable

7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37

Thickness
of
Insulation

1,780

Instrumentation &
Communication Cable

3C+E
3C+E
3C+E
3C+E
3C+E
3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth

EA

Max.
overall
dia.

2,330
3,140
4,300
5,330
6,620
8,060
10,400

Earthing & Bonding wire

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Min.
No. of
wires

200
260
340
450
650
930
1,430
1,880
2,570
3,510
4,790
5,880
7,140
9,010
11,720
14,500
240
310
420
560
790
1,150
1,670

VFD Cable

No.

Conductor

Nominal
Area

2,250
2,940
4,000

Technical Information

No. of
Cores

HV Power Cable

0.6/1kV RU

5,430
6,750
8,350
10,230
13,220

Offshore Cable

13

Halogen free & Mud resistant Offshore cable

LV Power & Lighting Cable


0.6/1kV RU
No. of
Cores

No.

5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44

14

Conductor
Nominal
Area

Min.
No. of
wires

mm2

EA

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4
4
4
4

Offshore Cable

Max.
overall
dia.
mm

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7

Thickness
of
Insulation

Thickness
of
sheath

mm

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

1.2
1.2
1.3
1.3
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.9
1.2
1.2
1.3
1.4
1.4
1.5
1.5
1.7
1.7
1.7
1.8
2.0
1.2
1.3
1.4
1.5
1.5
1.6
1.6
1.8
1.8
1.8
1.9
2.1
1.3
1.3
1.5
1.5
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.2

Overall diameter
Nominal

Tolerance

mm

mm

11.5
12.5
14.7
16.5
17.6
18.5
19.7
23.2
23.7
24.6
26.7
30.6
12.3
13.4
15.8
18.0
18.9
20.1
21.2
25.2
25.8
26.7
29.2
33.2
13.4
14.8
17.5
19.8
20.9
22.2
23.4
27.8
28.4
29.7
32.2
36.6
15.0
16.3
19.5
21.9
23.3
24.6
26.1
31.2
31.9
33.3
36.1
40.8

0.6
0.7
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.1
1.1
1.1
1.2
1.3
0.7
0.7
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.2
1.3
1.4
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight

/km

-km

V/5min.

kg/km

18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70

1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
940
940
940
940
940
940
940
940
940
940
940
940

3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

190
240
310
390
450
500
580
740
800
870
1,060
1,300
230
290
380
480
550
620
710
920
1,000
1,090
1,340
1,620
290
390
490
640
720
820
950
1,210
1,330
1,480
1,780
2,150
390
510
660
850
980
1,100
1,290
1,660
1,830
2,030
2,450
2,920

LV Power & Lighting Cable

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Cable Designation (P1, P1/P8)


LV Power & Lighting Cable

0.6/1kV RFOU, RFCU, RFBU

Application Standard
- Design guide

: NEK-606& IEC 60092-353

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

0.6/1kV RFOU

Sectional view

Classification

Code

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

Conductor
Insulation

Earthing & Bonding wire

Construction
R

- HF EPR as per IEC 60092-351


- Insulated cores shall be cabled

Cabling

- Flame retardant & non-hygroscopic fillers may be used


- Suitable tape(s) may be applied on the cabled core
- A Filler may be applied to obtain a circular Cable

Sheath

- Flame retardant halogen free thermoset compound

- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)

(B,C)
U

- A suitable separator tape(s) may be applied under/over the armor


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Black
No. of cores

Core identification

VFD Cable

Armor

Without Earth core

With Earth core

1C

Off-white or Black

2C

Off-white, Black

3C / 2C + E

Off-white, Black, Red

Off-white, Black, G/Y

4C / 3C + E

Off-white, Black, Red, Blue

Off-white, Black, Red, G/Y

5C / 4C + E

Black No. on white insulation

Off-white, Black, Red, Blue, G/Y

6C and over

Black No. on white insulation

Black No. on white insulation, G/Y

Technical Information

Inner covering

Note. 1. Flexible cable (Class5 Conductor) can be supplied

2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)

Offshore Cable

15

Halogen free & Mud resistant Offshore cable

LV Power & Lighting Cable


0.6/1kV RFOU, 0.6/1kV RFBU
No. of
Cores

No.

2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth

16

Conductor
Nominal
Area

Min.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Offshore Cable

7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37

1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5

Thickness Thickness
of
of
Insulation
inner
covering
mm

1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

mm

Nominal
dia.
inner
covering
mm

Dia. of Thickness
Overall diameter
wire for
of
Nominal
Tolerarmour
sheath
ance
mm

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight

mm

mm

mm

/km

-km

V/5min.

kg/km

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0

5.6
6.0
6.5
7.1
8.0
9.0
10.7
11.8
13.6
15.3
17.6
19.1
21.0
23.5
26.5
30.1
9.2
10.0
11.0
12.2
14.0
16.0
19.4
21.6
25.2
29.4
34.0
37.0
41.2
46.2
52.8
58.4
9.8
10.6
11.7
13.0
14.9
17.1
20.1

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3

1.1
1.1
1.1
1.1
1.2
1.2
1.3
1.3
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.1
1.2
1.3
1.3
1.3
1.4
1.5
1.6
1.7
1.9
2.0
2.2
2.3
2.5
2.7
3.0
3.2
1.2
1.3
1.3
1.4
1.4
1.5
1.7

9.3
9.7
10.2
10.8
11.9
12.9
14.8
15.9
17.9
19.8
22.3
23.8
25.9
28.6
31.8
36.2
13.1
14.1
15.1
16.3
18.3
20.5
24.1
26.5
30.5
34.9
40.3
43.5
48.1
53.5
60.7
66.7
13.7
14.7
15.8
17.3
19.2
21.6
25.0

0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.8
0.8
0.9
1.0
1.0
1.1
1.2
1.3
1.4
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.1
1.2
1.3
1.5
1.6
1.7
1.9
2.1
2.3
0.7
0.7
0.8
0.8
0.9
0.9
1.1

22.7

0.3

1.8

27.8

1.1

1.0

25.9

0.3

1.9

31.2

1.2

1.2

30.2

0.4

2.1

36.3

1.4

1.2

34.9

0.4

2.3

41.4

1.5

1.4

38.6

0.4

2.4

45.3

1.7

1.4

42.9

0.4

2.6

50.0

1.8

1.4

47.3

0.4

2.8

54.8

1.9

1.6

53.8

0.4

3.0

61.7

2.2

1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330

3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

150
170
200
230
290
370
520
630
810
1,060
1,380
1,650
1,970
2,430
3,090
3,940
290
340
400
480
610
790
1,120
1,390
1,820
2,450
3,320
3,950
4,800
5,910
7,630
9,260
320
380
460
570
730
980
1,300

1.0

12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154

1,690
2,090
2,920
3,830
4,730
5,790
6,870
8,760

LV Power & Lighting Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

4C+E
4C+E
4C+E
4C+E
4C+E
4C+E
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth

EA

mm
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5

7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37

mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0

mm
9.8
10.6
11.7
13.0
14.9
17.1
20.7
23.1
27.0
31.5
36.4
40.1
44.1
50.1
56.6
62.6
10.7
11.7
12.9
14.3
16.5
18.9
22.4

Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.2
1.3
1.3
1.4
1.4
1.5
1.7
1.8
1.9
2.1
2.3
2.5
2.6
2.9
3.1
3.4
1.3
1.3
1.4
1.4
1.5
1.6
1.7

mm
13.7
14.7
15.8
17.3
19.2
21.6
25.6
28.2
32.3
37.6
42.9
47.0
51.2
57.8
64.7
71.3
14.8
15.8
17.2
18.6
21.0
23.6
27.3

mm
0.7
0.7
0.8
0.8
0.9
0.9
1.1
1.1
1.3
1.4
1.6
1.7
1.8
2.0
2.2
2.4
0.7
0.8
0.8
0.9
0.9
1.0
1.1

1.0

25.3

0.3

1.9

30.6

1.2

1.2

29.8

0.3

2.0

35.3

1.4

1.2

33.7

0.4

2.2

40.0

1.5

1.4

39.5

0.4

2.4

46.2

1.7

1.4

43.2

0.4

2.6

50.3

1.8

1.4

47.9

0.4

2.8

55.4

2.0

1.6

53.7

0.4

3.0

61.6

2.1

1.6

60.4

0.4

3.3

68.9

2.4

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.6
1.8
1.0
1.0
1.0
1.0
1.0
1.0
1.0

10.7
11.7
12.9
14.3
16.5
18.9
23.0
25.7
30.8
34.9
40.9
44.5
49.7
55.7
62.9
70.1
11.7
12.8
14.2
15.8
18.2
20.9
25.0

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3

1.3
1.3
1.4
1.4
1.5
1.6
1.8
1.9
2.1
2.3
2.5
2.6
2.9
3.1
3.4
3.7
1.3
1.4
1.4
1.5
1.6
1.7
1.9

14.8
15.8
17.2
18.6
21.0
23.6
28.1
31.0
36.9
41.4
47.8
51.6
57.4
63.8
71.6
79.4
15.8
17.1
18.5
20.3
22.9
25.8
30.3

0.7
0.8
0.8
0.9
0.9
1.0
1.1
1.2
1.4
1.5
1.7
1.8
2.0
2.2
2.4
2.7
0.8
0.8
0.9
0.9
1.0
1.1
1.2

1.2

28.9

0.3

2.0

34.4

1.3

1.2

33.2

0.4

2.2

39.5

1.5

1.2

37.6

0.4

2.4

44.3

1.6

1.4

44.0

0.4

2.6

51.1

1.8

1.4

48.1

0.4

2.8

55.6

2.0

1.6

54.0

0.4

3.0

61.9

2.2

1.6

59.9

0.4

3.3

68.4

2.4

1.8

67.9

0.4

3.6

77.0

2.6

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154

-km
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330

Test
Voltage

Cable
Weight

V/5min.
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

kg/km
320
380
460
570
730
980
1,420
1,790
2,340
3,290
4,340
5,290
6,320
7,960
10,120
12,380
380
450
550
680
900
1,210
1,640

LV Power & Lighting Cable

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering

2,150

Instrumentation &
Communication Cable

3C+E
3C+E
3C+E
3C+E
3C+E
3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth

Max.
overall
dia.

2,790
3,770
5,040
6,160
7,520
9,150
11,610

Earthing & Bonding wire

Min.
No. of
wires

380
450
550
680
900
1,210
1,770
2,250
3,150
4,160
5,580
6,700
8,200
10,140
12,960
16,000
430
520
640
810
1,070
1,450
2,030

VFD Cable

No.

Conductor
Nominal
Area

2,720
3,550
4,680

Technical Information

No. of
Cores

HV Power Cable

0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU

6,270
7,660
9,460
11,460
14,670

Offshore Cable

17

Halogen free & Mud resistant Offshore cable

LV Power & Lighting Cable


0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU
No. of
Cores

No.

5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44

18

Conductor
Nominal
Area

Min.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4
4
4
4

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7

Thickness Thickness
of
of
Insulation
inner
covering
mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4

Nominal
dia.
inner
covering
mm

10.9
11.9
13.9
15.7
16.6
17.5
18.5
21.8
22.3
23.2
25.1
29.2
11.7
12.8
15.0
17.0
17.9
18.9
20.0
23.6
24.2
25.1
28.0
31.6
12.8
14.0
16.5
18.6
19.7
20.8
22.0
26.0
26.6
28.5
30.8
34.8
14.2
15.5
18.3
20.7
21.9
23.2
24.5
29.8
30.5
31.7
34.3
39.2

Dia. of Thickness
Overall diameter
wire for
of
Nominal
Tolerarmour
sheath
ance
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4

mm

mm

1.3
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.7
1.8
1.9
2.0
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.9
1.9
2.0
2.1
2.3
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
2.1
2.2
2.4

15.0
16.0
18.2
20.2
21.1
22.2
23.2
26.7
27.2
28.3
30.4
34.7
15.8
17.1
19.5
21.5
22.6
23.6
24.9
28.7
29.3
30.4
33.5
37.7
17.1
18.3
21.0
23.3
24.4
25.7
26.9
31.3
31.9
34.0
36.9
41.3
18.5
20.0
23.0
25.6
26.8
28.3
29.6
35.3
36.6
37.8
40.6
45.9

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight

mm

/km

-km

V/5min.

kg/km

0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.1
1.1
1.2
1.3
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.2
1.2
1.2
1.3
1.4
0.8
0.8
0.9
1.0
1.0
1.1
1.1
1.2
1.3
1.3
1.4
1.5
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.4
1.4
1.4
1.5
1.7

18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70

1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
940
940
940
940
940
940
940
940
940
940
940
940

3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

360
430
520
630
690
770
850
1,040
1,120
1,220
1,420
1,750
410
500
610
730
820
900
1,010
1,250
1,340
1,460
1,800
2,190
500
600
740
910
1,010
1,120
1,260
1,570
1,700
1,940
2,370
2,790
610
750
930
1,160
1,290
1,440
1,630
2,130
2,410
2,600
3,070
3,680

LV Power & Lighting Cable

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Cable Designation (P17)


LV Power & Lighting Cable

0.6/1kV BU

Application Standard
- Design guide

: NEK-606 & IEC 60092-353

- Flame retardant

: IEC 60332-1 &

IEC 60332-3 Category A

- Fire resistance

: IEC 60331-21(90min)
IEC 60331-1,-2(120min)

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

0.6/1KV BU

Sectional view

Classification

Code

Insulation

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

Conductor
Fire resisting layer

Earthing & Bonding wire

Construction

- Mica/glass tape
- HF EPR as per IEC 60092-351
- Insulated cores shall be cabled

Cabling

- Flame retardant & non-hygroscopic fillers may be used


- Suitable tape(s) may be applied on the cabled core
- A Filler may be applied to obtain a circular Cable
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Black
No. of cores

Core identification

Without Earth core

VFD Cable

With Earth core

1C

Off-white or Black

2C

Off-white, Black

3C / 2C + E

Off-white, Black, Red

Off-white, Black, G/Y

4C / 3C + E

Off-white, Black, Red, Blue

Off-white, Black, Red, G/Y

5C / 4C + E

Black No. on white insulation

Off-white, Black, Red, Blue, G/Y

6C and over

Black No. on white insulation

Black No. on white insulation, G/Y

Technical Information

Sheath

Note. 1. Flexible cable (Class5 Conductor) can be supplied

2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)

Offshore Cable

19

Halogen free & Mud resistant Offshore cable

LV Power & Lighting Cable


0.6/1kV BU
No. of
Cores

No.

2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth

20

Conductor
Nominal
Area

Min.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Offshore Cable

7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37

1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5

Thickness
of
Insulation

Thickness
of
sheath

mm

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

Overall diameter
Nominal

Tolerance

mm

mm

1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.4
1.5
1.6
1.7
1.8
1.9
1.1
1.2
1.2
1.2
1.3
1.4
1.5
1.6
1.8
1.9
2.1
2.2
2.4
2.5
2.8
3.0
1.2
1.2
1.2
1.3
1.4
1.4
1.6

6.3
6.7
7.2
7.8
8.9
9.9
11.8
12.9
14.9
16.8
19.1
20.9
22.9
25.4
28.6
31.8
10.6
11.6
12.6
13.8
15.8
18.0
21.6
24.0
28.0
31.8
36.8
40.2
44.2
49.0
55.6
61.6
11.4
12.3
13.4
14.9
17.0
19.2
22.6

0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7
0.8
0.9
0.9
1.0
1.1
1.2
1.3
0.6
0.6
0.7
0.7
0.8
0.8
0.9
1.0
1.1
1.3
1.4
1.5
1.6
1.8
2.0
2.1
0.6
0.7
0.7
0.7
0.8
0.9
1.0

1.7

25.4

1.1

1.8

29.0

1.2

1.9

32.6

1.3

2.1

37.8

1.4

2.3

41.7

1.6

2.4

46.0

1.7

2.6

50.4

1.8

2.8

56.8

2.0

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight

/km

-km

V/5min.

kg/km

12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154

1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330

3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

60
80
100
120
170
240
350
460
610
830
1,120
1,370
1,670
2,080
2,690
3,350
170
210
260
330
430
590
870
1,120
1,510
2,050
2,770
3,370
4,090
5,070
6,580
8,130
200
250
310
410
560
770
1,060
1,420
1,800
2,400
3,250
4,080
5,040
6,020
7,720

LV Power & Lighting Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

4C+E
4C+E
4C+E
4C+E
4C+E
4C+E
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth

mm
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5

Thickness
of
sheath

mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

mm
1.2
1.2
1.2
1.3
1.4
1.4
1.6
1.7
1.8
2.0
2.2
2.3
2.5
2.7
2.9
3.2
1.2
1.2
1.3
1.3
1.4
1.5
1.7

mm
11.4
12.3
13.4
14.9
17.0
19.2
23.2
25.8
30.1
34.1
39.5
43.1
47.4
52.8
59.6
66.3
12.5
13.5
14.9
16.3
18.7
21.3
25.3

mm
0.6
0.7
0.7
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.5
1.6
1.7
1.9
2.1
2.3
0.7
0.7
0.7
0.8
0.9
0.9
1.1

1.8

28.3

1.1

1.9

32.4

1.3

2.1

36.7

1.4

2.3

42.5

1.6

2.5

46.8

1.7

2.6

51.5

1.8

2.8

56.7

2.0

3.1

64.0

2.2

1.2
1.2
1.3
1.3
1.4
1.5
1.7
1.8
2.0
2.1
2.4
2.5
2.7
2.9
3.2
3.5
1.2
1.3
1.3
1.4
1.5
1.6
1.8

12.5
13.5
14.9
16.3
18.7
21.3
25.8
28.7
33.6
37.9
44.1
48.1
52.9
58.8
66.7
74.0
13.7
15.0
16.3
18.1
20.8
23.7
28.1

0.7
0.7
0.7
0.8
0.9
0.9
1.1
1.2
1.3
1.4
1.6
1.7
1.9
2.1
2.3
2.5
0.7
0.8
0.8
0.8
0.9
1.0
1.1

1.9

31.7

1.3

2.1

36.3

1.4

2.2

40.9

1.5

2.5

47.6

1.7

2.7

52.3

1.9

2.9

57.8

2.0

3.1

63.6

2.2

3.4

71.8

2.5

Overall diameter
Nominal

Tolerance

Conductor
Resistance
(at 20)
(Max.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154

Insulation
Resistance
(at 20)
(Min.)
-km
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330

Test
Voltage

Cable
Weight

V/5min.
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

kg/km
200
250
310
410
560
770
1,160
1,510
2,040
2,770
3,760
4,600
5,580
6,970
9,010
11,190
240
300
390
500
710
990
1,400

LV Power & Lighting Cable

7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37

Thickness
of
Insulation

1,850

Instrumentation &
Communication Cable

3C+E
3C+E
3C+E
3C+E
3C+E
3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth

EA

Max.
overall
dia.

2,390
3,230
4,370
5,460
6,710
8,110
10,460

Earthing & Bonding wire

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Min.
No. of
wires

240
300
390
500
710
990
1,500
1,950
2,650
3,580
4,890
5,980
7,260
9,060
11,770
14,600
290
370
470
620
870
1,230
1,750

VFD Cable

No.

Conductor
Nominal
Area

2,340
3,030
4,070

Technical Information

No. of
Cores

HV Power Cable

0.6/1kV BU

5,560
6,910
8,500
10,330
13,340

Offshore Cable

21

Halogen free & Mud resistant Offshore cable

LV Power & Lighting Cable


0.6/1kV BU
No. of
Cores

No.

5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44

22

Conductor
Nominal
Area

Min.
No. of
wires

mm2

EA

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4
4
4
4

Offshore Cable

Max.
overall
dia.
mm

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7

Thickness
of
Insulation

Thickness
of
sheath

mm

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

1.2
1.3
1.3
1.4
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
1.2
1.3
1.4
1.5
1.5
1.6
1.6
1.8
1.8
1.9
1.9
2.1
1.3
1.3
1.5
1.5
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.2
1.3
1.4
1.5
1.6
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.4

Overall diameter
Nominal

Tolerance

mm

mm

12.9
14.2
16.5
18.8
20.0
21.1
22.4
26.4
27.0
28.2
30.8
34.8
13.7
15.1
17.8
20.2
21.3
22.7
23.9
28.4
29.2
30.5
32.9
37.4
15.0
16.3
19.5
21.9
23.3
24.6
26.1
31.2
31.9
33.3
36.1
40.8
16.3
18.0
21.3
24.2
25.7
27.1
29.0
34.4
35.2
36.7
39.8
45.2

0.7
0.7
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.2
1.2
1.2
1.3
1.4
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5
0.8
0.8
0.9
1.0
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.7

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight

/km

-km

V/5min.

kg/km

18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70

1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
940
940
940
940
940
940
940
940
940
940
940
940

3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

230
300
370
480
550
610
710
900
980
1,090
1,330
1,580
270
350
450
580
650
740
850
1,090
1,210
1,340
1,600
1,920
340
440
580
730
840
940
1,100
1,430
1,570
1,730
2,090
2,480
440
580
740
960
1,110
1,250
1,480
1,880
2,070
2,290
2,770
3,320

LV Power & Lighting Cable

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Cable Designation (P5, P5/P12)


LV Power & Lighting Cable

0.6/1kV BFOU, BFCU, BFBU

Application Standard
- Design guide

: NEK-606 & IEC 60092-353

- Flame retardant

: IEC 60332-1 &

IEC 60332-3 Category A

- Fire resistance

: IEC 60331-21(90min)
IEC 60331-1,-2(120min)

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

0.6/1kV BFOU

Sectional view

Classification

Code

Insulation

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

Conductor
Fire resisting layer

Earthing & Bonding wire

Construction

- Mica/glass tape
- HF EPR as per IEC 60092-351
- Insulated cores shall be cabled

Cabling

- Flame retardant & non-hygroscopic fillers may be used


- Suitable tape(s) may be applied on the cabled core

Sheath

- Flame retardant halogen free thermoset compound

- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)

(B,C)
U

- A suitable separator tape(s) may be applied under/over the armor


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Black
No. of cores

Core identification

Without Earth core

With Earth core

1C

Off-white or Black

2C

Off-white, Black

3C / 2C + E

Off-white, Black, Red

Off-white, Black, G/Y

4C / 3C + E

Off-white, Black, Red, Blue

Off-white, Black, Red, G/Y

5C / 4C + E

Black No. on white insulation

Off-white, Black, Red, Blue, G/Y

6C and over

Black No. on white insulation

Black No. on white insulation, G/Y

Technical Information

Armor

VFD Cable

- A Filler may be applied to obtain a circular Cable


Inner covering

Note. 1. Flexible cable (Class5 Conductor) can be supplied

2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)

Offshore Cable

23

Halogen free & Mud resistant Offshore cable

LV Power & Lighting Cable


0.6/1kV BFOU, 0.6/1kV BFBU
No. of
Cores

No.

2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth

24

Conductor
Nominal
Area

Min.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Offshore Cable

7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37

1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

mm

mm

Dia. of
wire for
armour
mm

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

mm

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0

6.1
6.5
7.0
7.6
8.5
9.5
11.2
12.3
14.1
15.8
18.1
19.7
21.5
23.8
26.8
30.4
10.2
11.0
12.0
13.2
15.0
17.0
20.4
22.6
26.2
30.4
35.0
38.6
42.2
46.8
53.4
59.0
10.8
11.7
12.8
14.1
16.0
18.2
21.2

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3

1.1
1.1
1.1
1.2
1.2
1.2
1.3
1.3
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.1
1.3
1.3
1.3
1.4
1.5
1.5
1.7
1.8
1.9
2.1
2.3
2.4
2.6
2.7
3.0
3.2
1.3
1.3
1.4
1.4
1.5
1.6
1.7

9.8
10.2
10.7
11.5
12.4
13.4
15.3
16.4
18.4
20.3
22.8
24.4
26.4
28.9
32.1
36.5
14.3
15.1
16.1
17.5
19.5
21.5
25.3
27.7
31.5
36.5
41.5
45.3
49.3
54.1
61.3
67.3
14.9
15.8
17.1
18.4
20.5
22.9
26.1

0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
1.4
0.7
0.8
0.8
0.8
0.9
0.9
1.1
1.1
1.2
1.4
1.5
1.7
1.8
1.9
2.1
2.3
0.7
0.8
0.8
0.9
0.9
1.0
1.1

1.0

23.8

0.3

1.8

28.9

1.2

1.0

27.0

0.3

1.9

32.3

1.3

1.2

31.2

0.4

2.1

37.3

1.4

1.2

36.0

0.4

2.3

42.5

1.6

1.4

39.9

0.4

2.5

46.8

1.7

1.4

44.0

0.4

2.6

51.1

1.8

1.4

48.0

0.4

2.8

55.5

2.0

1.6

54.6

0.4

3.1

62.7

2.2

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight

/km

-km

V/5min.

kg/km

12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154

1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330

3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

170
190
210
250
310
390
530
650
830
1,080
1,410
1,680
2,000
2,440
3,100
3,960
330
380
450
540
660
840
1,170
1,450
1,870
2,620
3,410
4,130
4,900
5,950
7,670
9,310
370
430
520
630
800
1,050
1,360
1,750
2,150
2,990
3,910
4,850
5,880
6,920
8,860

LV Power & Lighting Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

4C+E
4C+E
4C+E
4C+E
4C+E
4C+E
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth

EA

mm
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5

7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37

mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

Dia. of
wire for
armour

Thickness
Overall diameter
of
Nominal
Tolersheath
ance

mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0

mm
10.8
11.7
12.8
14.1
16.0
18.2
21.8
24.2
28.9
32.5
37.5
41.3
45.2
50.8
57.2
63.3
11.9
12.9
14.1
15.5
17.7
20.1
23.7

mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3

mm
1.3
1.3
1.4
1.4
1.5
1.6
1.7
1.8
2.0
2.2
2.4
2.5
2.7
2.9
3.2
3.4
1.3
1.4
1.4
1.5
1.6
1.7
1.8

mm
14.9
15.8
17.1
18.4
20.5
22.9
26.7
29.3
34.4
38.8
44.2
48.2
52.5
58.5
65.5
72.0
16.0
17.2
18.4
20.0
22.4
25.0
28.8

mm
0.7
0.8
0.8
0.9
0.9
1.0
1.1
1.2
1.3
1.5
1.6
1.7
1.9
2.1
2.3
2.5
0.8
0.8
0.9
0.9
1.0
1.1
1.2

1.0

26.5

0.3

1.9

31.8

1.3

1.2

31.0

0.4

2.1

37.1

1.4

1.2

34.9

0.4

2.3

41.4

1.5

1.4

40.7

0.4

2.5

47.6

1.7

1.4

44.6

0.4

2.7

51.9

1.9

1.6

49.7

0.4

2.9

57.4

2.0

1.6

54.5

0.4

3.0

62.4

2.2

1.6

61.2

0.4

3.3

69.7

2.4

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.6
1.8
1.0
1.0
1.0
1.0
1.0
1.0
1.0

11.9
12.9
14.1
15.5
17.7
20.1
24.2
26.9
32.0
36.1
42.1
45.9
50.9
56.4
63.7
70.8
13.1
14.2
15.5
17.1
19.6
22.3
26.3

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3

1.3
1.4
1.4
1.5
1.6
1.7
1.8
1.9
2.1
2.3
2.6
2.7
2.9
3.1
3.4
3.7
1.4
1.4
1.5
1.5
1.6
1.7
1.9

16.0
17.2
18.4
20.0
22.4
25.0
29.3
32.2
38.1
42.6
49.2
53.2
58.6
64.5
72.4
80.1
17.4
18.5
20.0
21.6
24.3
27.2
31.6

0.8
0.8
0.9
0.9
1.0
1.1
1.2
1.3
1.4
1.6
1.8
1.9
2.1
2.2
2.5
2.7
0.8
0.9
0.9
0.9
1.0
1.1
1.2

1.2

30.3

0.4

2.1

36.4

1.4

1.2

34.5

0.4

2.2

40.8

1.5

1.4

39.3

0.4

2.4

46.0

1.7

1.4

45.4

0.4

2.7

52.7

1.9

1.6

50.3

0.4

2.9

58.0

2.0

1.6

55.4

0.4

3.1

63.5

2.2

1.6

60.8

0.4

3.3

69.3

2.4

1.8

68.8

0.4

3.6

77.9

2.6

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154

-km
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330

Test
Voltage

Cable
Weight

V/5min.
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

kg/km
370
430
520
630
800
1,050
1,470
1,850
2,510
3,380
4,440
5,390
6,440
8,010
10,200
12,440
430
510
610
750
980
1,290
1,730

LV Power & Lighting Cable

mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering

2,220

Instrumentation &
Communication Cable

3C+E
3C+E
3C+E
3C+E
3C+E
3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth

Max.
overall
dia.

2,970
3,870
5,160
6,310
7,770
9,220
11,680

Earthing & Bonding wire

Min.
No. of
wires

430
510
610
750
980
1,290
1,830
2,320
3,230
4,240
5,700
6,850
8,310
10,200
13,030
16,060
500
590
720
880
1,160
1,540
2,110

VFD Cable

No.

Conductor
Nominal
Area

2,910
3,640
4,840

Technical Information

No. of
Cores

HV Power Cable

0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU

6,420
7,950
9,630
11,540
14,760

Offshore Cable

25

Halogen free & Mud resistant Offshore cable

LV Power & Lighting Cable


0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU
No. of
Cores

No.

5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44

26

Conductor
Nominal
Area

Min.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4
4
4
4

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4

mm

12.3
13.4
15.7
17.8
18.8
19.9
21.0
24.8
25.4
26.4
29.4
33.2
13.1
14.3
16.8
19.0
20.1
21.3
22.5
26.6
28.0
29.1
31.5
35.6
14.2
15.5
18.3
20.7
21.9
23.2
24.5
29.8
30.5
31.7
34.3
39.2
15.5
17.0
20.1
22.8
24.1
25.5
27.0
32.8
33.6
34.9
37.8
43.2

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.3
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.2
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.0
2.1
2.3
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
2.1
2.2
2.4
1.5
1.5
1.7
1.8
1.8
1.9
1.9
2.2
2.2
2.3
2.4
2.6

mm

16.4
17.7
20.2
22.5
23.5
24.6
25.9
29.9
30.7
31.7
34.9
39.5
17.4
18.6
21.3
23.7
25.0
26.2
27.6
31.9
33.5
34.6
37.6
42.1
18.5
20.0
23.0
25.6
26.8
28.3
29.6
35.3
36.6
37.8
40.6
45.9
20.0
21.5
25.0
27.9
29.2
30.8
32.3
39.1
39.9
41.4
44.5
50.3

mm

0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.5
0.8
0.9
0.9
1.0
1.1
1.1
1.1
1.3
1.3
1.3
1.4
1.6
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.4
1.4
1.4
1.5
1.7
0.9
0.9
1.1
1.1
1.2
1.2
1.3
1.5
1.5
1.5
1.6
1.8

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight

/km

-km

V/5min.

kg/km

18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70

1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
940
940
940
940
940
940
940
940
940
940
940
940

3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

420
500
610
750
820
900
1,010
1,240
1,350
1,450
1,790
2,200
480
570
700
850
950
1,050
1,180
1,460
1,670
1,800
2,190
2,580
560
680
840
1,040
1,150
1,280
1,440
1,890
2,140
2,310
2,710
3,250
680
830
1,040
1,300
1,450
1,620
1,830
2,500
2,700
2,940
3,460
4,160

Instrumentation & Communication Cable

250V RU(c)

28 ~ 30

250V RU(i)

31 ~ 33

250V RU(i&c)

34 ~ 36

250V RFOU(c), RFCU(c), RFBU(c)

37 ~ 39

250C RFOU(i), RFCU(i), RFBU(i)

40 ~ 42

250V RFOU(i&c), RFCU(i&c), RFBU(i&c)

43 ~ 45

250V BU(c)

46 ~ 48

250V BU(i)

49 ~ 51

250V BU(i&c)

52 ~ 54

250V BFOU(c), BFCU(c), BFBU(c)

55 ~ 57

250C BFOU(i), BFCU(i), BFBU(i)

58 ~ 60

250V BFOU(i&c), BFCU(i&c), BFBU(i&c)

61 ~ 63

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable

Cable Designation (S12)


250V RU(c)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &

250V RU(c)

IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Construction
Sectional view

Classification

Code

Conductor
Insulation

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

Twisting

- HF EPR as per IEC 60092-351


- Two/Three Insulated cores shall be twisted together to form a pair/Triad
- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core


- A Filler may be applied to obtain a circular Cable

Collective screen

(c)

Sheath

- CU/PS or AL/PS tape + Tinned copper drain wire


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note. Flexible cable (Class5 Conductor) can be supplied

28

Offshore Cable

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

mm

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.0
1.1
1.1
1.2
1.2
1.3
1.3
1.3
1.4
1.4
1.4
1.5
1.5
1.6
1.8
1.0
1.1
1.2
1.2
1.3
1.3
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.8
1.0
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.7
1.9
2.1
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.5
1.7
1.7
1.7
1.8
1.9
2.0
2.2

Overall diameter
Nominal

Tolerance

mm

mm

7.0
10.4
11.1
12.0
13.4
14.5
14.5
15.4
17.5
18.2
18.8
20.4
21.3
24.3
27.9
7.4
11.1
12.1
12.8
14.5
15.5
15.5
16.5
18.7
19.7
20.4
21.9
23.1
26.3
30.2
8.4
13.0
14.1
15.0
17.0
18.2
18.2
19.6
22.2
23.1
24.0
26.0
27.2
31.4
36.0
9.4
14.6
15.6
16.8
18.8
20.4
20.4
21.8
24.9
25.9
26.9
29.4
30.9
35.2
40.4

0.5
0.6
0.6
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
0.5
0.6
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.2
0.6
0.7
0.7
0.8
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.4
0.6
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.2
1.4
1.5

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

80
140
170
210
240
280
310
340
420
470
530
600
680
850
1,110
90
160
200
240
290
330
360
400
490
570
640
720
830
1,030
1,350
110
210
270
320
390
450
490
560
680
780
870
1,000
1,140
1,460
1,900
150
270
340
430
510
600
660
740
930
1,060
1,200
1,390
1,610
2,000
2,620

Offshore Cable

LV Power & Lighting Cable

EA

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Thickness
of
Insulation

Instrumentation &
Communication Cable

mm2

Max.
overall
dia.

Earthing & Bonding wire

1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

Max.
No. of
wires

VFD Cable

No.

Conductor
Nominal
Area

Technical Information

No. of
Pairs

HV Power Cable

250V RU(c)

29

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V RU(c)
No. of
Triads

No.

1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

30

Conductor
Nominal
Area

Max.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
Insulation

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.0
1.2
1.2
1.2
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
2.0
1.0
1.2
1.2
1.3
1.3
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.9
2.1
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.4
1.1
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.0
2.0
2.2
2.3
2.6

Overall diameter
Nominal

Tolerance

mm

mm

7.4
11.6
12.3
13.5
15.1
17.1
17.1
18.3
20.8
22.2
23.1
24.5
26.6
29.7
34.3
7.8
12.3
13.1
14.5
16.0
18.2
18.2
19.7
22.4
23.6
24.6
26.4
28.6
32.0
36.9
9.1
14.5
15.4
17.1
18.9
21.5
21.5
23.2
26.4
28.1
29.5
31.5
34.2
38.0
44.0
10.0
16.0
17.3
19.0
21.3
24.2
24.2
26.1
30.0
31.9
33.4
35.5
38.7
43.0
49.8

0.5
0.6
0.7
0.7
0.8
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.3
0.5
0.7
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.3
1.4
0.6
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.6
0.6
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

100
180
220
270
330
390
430
470
580
680
760
850
1,000
1,250
1,630
110
210
260
320
380
460
500
570
710
810
910
1,030
1,210
1,510
1,980
140
270
340
430
520
620
680
780
960
1,120
1,290
1,460
1,710
2,100
2,780
180
350
460
570
700
840
930
1,070
1,340
1,560
1,790
2,010
2,380
2,930
3,880

Instrumentation & Communication Cable

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Cable Designation (S11)


LV Power & Lighting Cable

250V RU(i)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

250V RU(i)

Sectional view

Classification

Code

Conductor
Insulation

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

Twisting
Individual screen

Earthing & Bonding wire

Construction

- HF EPR as per IEC 60092-351


- Two/Three Insulated cores shall be twisted together to form a pair/Triad

(i)

- CU/PS or AL/PS tape + Tinned copper drain wire


- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core


- A Filler may be applied to obtain a circular Cable
U

- SHF2 or SHF Mud as per IEC 60092-359

VFD Cable

Sheath

- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)


- Each Pair / Triad : Core color

Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape

Technical Information

Note. Flexible cable (Class5 Conductor) can be supplied

Offshore Cable

31

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V RU(i)
No. of
Pairs

No.

1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

32

Conductor
Nominal
Area

Max.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
Insulation

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.0
1.1
1.2
1.2
1.3
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.0
1.2
1.2
1.2
1.3
1.3
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
1.0
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
1.1
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.8
1.8
1.9
1.9
2.2
2.3

Overall diameter
Nominal

Tolerance

mm

mm

7.0
11.1
11.9
13.0
14.7
15.2
15.2
16.8
19.0
20.0
20.9
22.6
23.1
27.0
29.6
7.4
12.0
12.7
13.8
15.6
16.2
16.2
17.9
20.5
21.3
22.6
24.2
24.9
29.3
31.9
8.4
13.7
14.7
16.1
18.2
18.9
18.9
20.9
24.0
25.1
26.4
28.5
29.3
34.4
37.5
9.4
15.3
16.2
18.0
20.3
21.1
21.1
23.4
26.8
28.0
29.7
32.0
32.7
38.6
42.0

0.5
0.6
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.2
0.5
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.2
1.3
0.6
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
0.6
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.3
1.3
1.5
1.6

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

40
70
110
140
170
200
240
270
340
400
470
540
630
800
1,060
90
180
230
280
350
400
440
510
630
720
830
930
1,080
1,380
1,760
120
230
300
370
450
520
570
660
820
960
1,080
1,240
1,430
1,820
2,330
150
290
380
490
600
690
760
880
1,090
1,280
1,470
1,680
1,920
2,470
3,170

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

mm

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.0
1.2
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.1
1.0
1.2
1.2
1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.2
1.1
1.3
1.3
1.4
1.5
1.6
1.6
1.6
1.8
1.8
1.9
1.9
2.0
2.2
2.4
1.1
1.3
1.4
1.5
1.5
1.7
1.7
1.7
1.9
1.9
2.0
2.1
2.2
2.4
2.6

Overall diameter
Nominal

Tolerance

mm

mm

7.4
12.0
12.8
14.2
15.7
17.9
17.9
19.1
21.7
23.2
24.2
25.8
28.0
31.4
36.2
7.8
12.8
13.5
15.1
16.9
19.0
19.0
20.5
23.3
24.9
25.9
27.7
30.0
33.6
38.8
9.1
14.9
15.8
17.6
19.7
22.4
22.4
24.0
27.6
29.3
30.8
32.7
35.5
39.6
45.7
10.0
16.5
17.7
19.7
21.9
25.1
25.1
26.9
31.1
32.9
34.5
36.9
40.0
44.6
51.4

0.5
0.7
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.4
0.5
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.3
1.5
0.6
0.7
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.7
0.6
0.8
0.8
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

150
280
340
420
490
590
630
700
850
980
1,100
1,230
1,430
1,760
2,360
110
220
280
360
450
520
580
660
820
970
1,090
1,250
1,460
1,830
2,410
150
290
370
480
590
710
780
880
1,110
1,300
1,490
1,670
1,960
2,460
3,220
190
370
500
640
770
950
1,060
1,190
1,510
1,750
2,020
2,290
2,690
3,370
4,420

Offshore Cable

LV Power & Lighting Cable

EA

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Thickness
of
Insulation

Instrumentation &
Communication Cable

mm2

Max.
overall
dia.

Earthing & Bonding wire

1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

Max.
No. of
wires

VFD Cable

No.

Conductor
Nominal
Area

Technical Information

No. of
Triads

HV Power Cable

250V RU(i)

33

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable

Cable Designation
250V RU(i&c)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &

250V RU(i&c)

IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Construction
Sectional view

Classification

Code

Conductor
Insulation

Twisting
Individual screen

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad

(i)

- CU/PS or AL/PS tape + Tinned copper drain wire


- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core


- A Filler may be applied to obtain a circular Cable

Collective screen

(c)

Sheath

- CU/PS or AL/PS tape + Tinned copper drain wire


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note. Flexible cable (Class5 Conductor) can be supplied

34

Offshore Cable

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

mm

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.2
1.2
1.2
1.3
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.2
1.2
1.3
1.3
1.3
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.8
1.8
1.9
1.9
2.2
2.3

Overall diameter
Nominal

Tolerance

mm

mm

11.4
12.0
13.1
14.8
15.3
15.3
16.9
19.1
20.1
21.0
22.7
23.2
27.1
29.7
12.1
12.8
14.1
15.7
16.3
16.3
18.0
20.6
21.4
22.7
24.3
25.0
29.4
32.0
13.8
14.8
16.2
18.3
19.0
19.0
21.0
24.1
25.2
26.5
28.6
29.4
34.5
37.6
15.4
16.3
18.1
20.4
21.2
21.2
23.5
26.9
28.1
29.8
32.1
32.8
38.7
42.1

0.6
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.2
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.3
1.3
1.5
1.6

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

170
210
260
310
350
380
440
530
620
700
800
900
1,130
1,470
200
250
310
370
420
460
530
650
740
860
960
1,110
1,410
1,800
240
320
390
470
540
590
680
840
980
1,110
1,270
1,460
1,850
2,360
320
400
510
620
710
790
910
1,120
1,310
1,510
1,710
1,960
2,510
3,210

Offshore Cable

LV Power & Lighting Cable

EA

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Thickness
of
Insulation

Instrumentation &
Communication Cable

mm2

Max.
overall
dia.

Earthing & Bonding wire

2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

Max.
No. of
wires

VFD Cable

No.

Conductor
Nominal
Area

Technical Information

No. of
Pairs

HV Power Cable

250V RU(i&c)

35

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V RU(i&c)
No. of
Triads

No.

2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

36

Conductor
Nominal
Area

Max.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
Insulation

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.2
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.1
1.2
1.2
1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.2
1.3
1.3
1.4
1.5
1.6
1.6
1.6
1.8
1.8
1.9
1.9
2.0
2.2
2.4
1.4
1.4
1.5
1.6
1.7
1.7
1.7
1.9
2.0
2.0
2.1
2.2
2.4
2.6

Overall diameter
Nominal

Tolerance

mm

mm

12.1
12.9
14.3
15.8
18.0
18.0
19.2
21.8
23.3
24.3
25.9
28.1
31.5
36.3
12.9
13.6
15.2
17.0
19.1
19.1
20.6
23.4
25.0
26.0
27.8
30.1
33.7
38.9
15.0
15.9
17.7
19.8
22.5
22.5
24.1
27.7
29.4
30.9
32.8
35.6
39.7
45.8
16.8
17.8
19.8
22.2
25.2
25.2
27.0
31.2
33.2
34.6
37.0
40.1
44.7
51.5

0.7
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.4
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.5
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.7
0.8
0.8
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

200
260
320
380
460
510
570
700
820
920
1,050
1,230
1,540
2,010
240
300
380
470
550
600
690
850
990
1,120
1,270
1,490
1,870
2,450
310
390
500
610
730
810
900
1,140
1,330
1,520
1,700
2,000
2,490
3,270
400
520
660
810
980
1,080
1,220
1,550
1,810
2,050
2,330
2,730
3,410
4,470

Instrumentation & Communication Cable

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Cable Designation (S2, S2/S6)


LV Power & Lighting Cable

250V RFOU(c), RFCU(c), RFBU(c)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

250V RFOU(c)

Sectional view

Classification

Code

Conductor
Insulation

Earthing & Bonding wire

Construction
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
R

Twisting

- HF EPR as per IEC 60092-351


- Two/Three Insulated cores shall be twisted together to form a pair/Triad
- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core

Inner covering
Armor
Sheath

(c)

- CU/PS or AL/PS tape + Tinned copper drain wire

- Flame retardant halogen free thermoset compound

- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)

(B,C)
U

VFD Cable

- A Filler may be applied to obtain a circular Cable


Collective screen

- A suitable separator tape(s) may be applied under/over the armor


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

Technical Information

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note. Flexible cable (Class5 Conductor) can be supplied

Offshore Cable

37

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V RFOU(c), 250V RFCU(c), 250V RFBU(c)
No. of
Pairs

Conductor
Nominal
Area

Max.
No. of
wires

Max.
overall
dia.

No.

mm2

EA

mm

1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4Pi
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

38

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4

mm

6.8
10.0
10.7
11.4
12.8
13.7
13.7
14.6
16.5
17.2
17.8
19.2
20.1
22.9
26.1
7.2
10.7
11.5
12.2
13.7
14.7
14.7
15.7
17.7
18.5
19.2
20.7
21.7
24.7
29.0
8.2
12.4
13.3
14.2
16.0
17.2
17.2
18.4
20.8
21.7
22.6
24.4
25.6
30.0
34.2
9.0
13.8
14.8
15.8
17.8
19.2
19.2
20.6
23.3
24.3
25.3
28.2
29.5
33.6
38.8

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.1
1.3
1.3
1.3
1.4
1.4
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
1.1
1.3
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.7
1.8
2.0
1.2
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
1.9
2.1
2.2
1.2
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.0
2.2
2.4

mm

10.5
14.1
14.8
15.5
17.1
18.0
18.0
18.9
21.0
21.7
22.5
23.9
25.0
28.0
31.4
10.9
14.8
15.6
16.3
18.0
19.0
19.0
20.2
22.4
23.2
23.9
25.6
26.6
29.8
34.5
12.1
16.5
17.6
18.5
20.5
21.7
21.7
23.1
25.7
26.6
27.7
29.5
30.9
35.7
40.5
12.9
18.1
19.1
20.3
22.5
23.9
23.9
25.5
28.4
29.4
30.6
33.7
35.0
39.9
45.5

mm

0.6
0.7
0.7
0.8
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
0.6
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.3
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.1
1.2
1.2
1.4
1.5
0.7
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.2
1.3
1.4
1.5
1.7

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

200
300
340
380
450
490
520
560
660
730
800
880
980
1,190
1,470
210
340
380
430
500
550
580
650
760
840
920
1,030
1,140
1,370
1,820
250
400
470
530
630
700
740
820
980
1,090
1,210
1,340
1,510
1,940
2,510
290
480
570
660
780
880
940
1,050
1,250
1,400
1,560
1,850
2,070
2,630
3,380

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

mm2

EA

mm

1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4

mm

7.2
11.0
11.7
12.9
14.3
16.1
16.1
17.3
19.6
20.8
21.7
23.1
25.0
28.5
32.7
7.6
11.7
12.5
13.7
15.2
17.2
17.2
18.5
21.0
22.2
23.2
24.8
26.8
30.6
35.1
8.7
13.7
14.6
16.1
17.9
20.3
20.3
21.8
24.8
26.3
28.3
30.1
32.6
36.2
42.0
9.6
15.2
16.3
18.0
20.1
22.8
22.8
24.5
28.8
30.5
31.8
33.9
36.7
41.2
47.4

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.2
1.2
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
1.9
2.1
2.3
1.2
1.4
1.4
1.5
1.6
1.7
1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.3
2.5
1.2
1.5
1.5
1.6
1.7
1.8
1.8
1.8
2.0
2.1
2.1
2.2
2.3
2.5
2.8

mm

10.9
15.1
15.8
17.2
18.6
20.6
20.6
21.8
24.3
25.7
26.6
28.2
30.3
34.0
39.0
11.5
15.8
16.8
18.0
19.7
21.7
21.7
23.2
25.9
27.1
28.3
29.9
32.1
36.7
41.6
12.6
18.0
18.9
20.6
22.6
25.2
25.2
26.7
29.9
31.6
33.8
36.2
38.9
42.7
48.9
13.5
19.7
20.8
22.7
25.0
27.9
27.9
29.6
34.3
36.6
37.9
40.2
43.2
48.1
54.9

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

mm

/km

-km

V/5min.

kg/km

0.6
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.1
1.2
1.3
1.5
0.6
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.5
0.7
0.8
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.8
0.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.6
1.7
1.9

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

220
350
400
470
540
630
670
730
870
980
1,070
1,190
1,360
1,710
2,240
240
390
460
530
620
710
760
840
1,000
1,120
1,250
1,380
1,580
2,090
2,620
290
480
570
670
790
930
990
1,090
1,310
1,490
1,750
2,030
2,320
2,770
3,560
340
590
710
850
1,010
1,180
1,270
1,410
1,800
2,140
2,370
2,640
3,020
3,730
4,770

Offshore Cable

LV Power & Lighting Cable

No.

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering

Instrumentation &
Communication Cable

Max.
overall
dia.

Earthing & Bonding wire

Max.
No. of
wires

VFD Cable

Conductor
Nominal
Area

Technical Information

No. of
Triads

HV Power Cable

250V RFOU(c), 250V RFCU(c), 250V RFBU(c)

39

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable

Cable Designation (S1, S1/S5)


250V RFOU(i), RFCU(i), RFBU(i)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &

250V RFOU(i)

IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Construction
Sectional view

Classification

Code

Conductor
Insulation

Twisting
Individual screen

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad

(i)

- CU/PS or AL/PS tape + Tinned copper drain wire


- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core


- A Filler may be applied to obtain a circular Cable

Inner covering
Armor
Sheath

- Flame retardant halogen free thermoset compound

- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)

(B,C)
U

- A suitable separator tape(s) may be applied under/over the armor


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note. Flexible cable (Class5 Conductor) can be supplied

40

Offshore Cable

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

mm2

EA

mm

1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4

mm

6.8
10.7
11.3
12.4
13.9
14.4
14.4
15.8
18.0
18.8
19.7
21.2
21.7
25.4
28.4
7.2
11.4
12.1
13.2
14.8
15.4
15.4
16.9
19.3
20.1
21.2
22.8
23.3
28.1
30.5
8.2
13.1
13.9
15.3
17.2
17.9
17.9
19.7
22.6
23.5
24.8
26.7
28.1
32.8
35.7
9.0
14.5
15.4
17.0
19.1
19.9
19.9
22.0
25.2
26.2
28.5
30.6
31.3
36.6
40.2

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.1
1.3
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.7
1.9
2.0
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
1.2
1.4
1.4
1.5
1.5
1.6
1.6
1.6
1.8
1.8
1.8
1.9
2.0
2.2
2.3
1.2
1.4
1.5
1.5
1.6
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.1
2.3
2.5

mm

10.5
14.8
15.4
16.5
18.2
18.7
18.7
20.3
22.7
23.5
24.4
26.1
26.6
30.7
33.9
10.9
15.5
16.2
17.5
19.1
19.9
19.9
21.4
24.0
25.0
26.1
27.9
28.4
33.6
36.6
12.1
17.4
18.2
19.8
21.7
22.6
22.6
24.4
27.7
28.6
29.9
32.0
33.6
39.1
42.2
12.9
18.8
19.9
21.5
23.8
24.6
24.6
26.9
30.5
31.5
34.0
36.7
37.4
43.1
47.1

mm

0.6
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.3
0.6
0.8
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
0.7
0.8
0.8
0.9
1.0
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.5
1.6
0.7
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.7

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

200
330
380
430
510
550
590
660
790
880
960
1,080
1,190
1,480
1,900
210
360
420
490
570
640
680
760
910
1,020
1,130
1,270
1,410
1,830
2,340
260
440
510
610
710
790
850
940
1,150
1,280
1,430
1,600
1,890
2,430
2,980
300
510
620
740
880
970
1,050
1,190
1,460
1,640
1,940
2,260
2,510
3,110
3,950

Offshore Cable

LV Power & Lighting Cable

No.

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering

Instrumentation &
Communication Cable

Max.
overall
dia.

Earthing & Bonding wire

Max.
No. of
wires

VFD Cable

Conductor
Nominal
Area

Technical Information

No. of
Pairs

HV Power Cable

250V RFOU(i), 250V RFCU(i), 250V RFBU(i)

41

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V RFOU(i), 250V RFCU(i), 250V RFBU(i)
No. of
Triads

Conductor
Nominal
Area

Max.
No. of
wires

Max.
overall
dia.

No.

mm2

EA

mm

1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

42

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.4
1.6

mm

7.2
11.4
12.2
13.4
14.9
16.9
16.9
18.1
20.5
21.8
22.8
24.2
26.2
30.0
34.4
7.6
12.2
12.9
14.3
15.9
18.0
18.0
19.3
21.9
23.3
24.3
25.9
28.8
32.0
36.8
8.7
14.1
15.0
16.6
18.5
21.0
21.0
22.6
25.8
28.1
29.4
31.3
33.9
37.6
43.7
9.6
15.7
16.7
18.5
20.7
23.5
23.5
25.3
29.7
31.5
32.9
35.1
38.4
42.6
49.6

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.7
1.8
1.8
1.9
2.1
2.2
1.2
1.3
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.3
1.2
1.4
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.0
2.1
2.2
2.4
2.6
1.2
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.6
2.9

mm

10.9
15.5
16.3
17.7
19.2
21.4
21.4
22.8
25.4
26.7
27.9
29.3
31.5
35.7
40.7
11.5
16.3
17.2
18.6
20.4
22.7
22.7
24.0
26.8
28.4
29.4
31.2
34.3
38.1
43.3
12.6
18.4
19.5
21.1
23.2
25.9
25.9
27.7
31.1
33.6
34.9
37.4
40.2
44.3
50.8
13.5
20.2
21.2
23.2
25.6
28.6
28.6
30.6
35.2
37.6
39.2
41.6
45.1
49.7
57.3

mm

0.6
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.2
1.4
1.5
0.6
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.2
1.3
1.4
1.6
0.7
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8
0.7
0.9
0.9
1.0
1.1
1.2
1.2
1.2
1.4
1.4
1.5
1.5
1.7
1.8
2.0

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

220
370
430
510
590
690
740
820
980
1,110
1,230
1,360
1,560
1,990
2,590
240
410
490
580
680
800
860
940
1,130
1,290
1,430
1,600
1,930
2,410
3,060
290
500
610
720
860
1,010
1,080
1,210
1,460
1,760
1,950
2,260
2,590
3,140
4,060
340
610
750
910
1,080
1,270
1,380
1,550
1,970
2,350
2,630
2,940
3,440
4,180
5,480

Instrumentation & Communication Cable

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Cable Designation
LV Power & Lighting Cable

250V RFOU(i&c), RFCU(i&c), RFBU(i&c)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

250V RFOU(i&c)

Sectional view

Classification

Code

Conductor
Insulation

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

Twisting
Individual screen

Earthing & Bonding wire

Construction

- HF EPR as per IEC 60092-351


- Two/Three Insulated cores shall be twisted together to form a pair/Triad

(i)

- CU/PS or AL/PS tape + Tinned copper drain wire


- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core

Collective screen

(c)

- CU/PS or AL/PS tape + Tinned copper drain wire

Inner covering

- Flame retardant halogen free thermoset compound

- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)

Armor
Sheath

(B,C)
U

VFD Cable

- A Filler may be applied to obtain a circular Cable

- A suitable separator tape(s) may be applied under/over the armor


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color
Pair : Black, Light blue

Triad : Black, Light blue, Brown

Technical Information

Core identification

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note. Flexible cable (Class5 Conductor) can be supplied

Offshore Cable

43

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V RFOU(i&c), 250V RFCU(i&c), 250V RFBU(i&c)
No. of
Pairs

Conductor
Nominal
Area

Max.
No. of
wires

Max.
overall
dia.

No.

mm2

EA

mm

2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

44

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4

mm

10.8
11.4
12.5
14.0
14.5
14.5
15.9
18.1
18.9
19.8
21.3
21.8
25.5
28.5
11.5
12.2
13.3
14.9
15.5
15.5
17.0
19.4
20.2
21.3
22.9
23.4
28.2
30.6
13.2
14.0
15.4
17.3
18.0
18.0
19.8
22.7
23.6
24.9
26.8
28.2
32.9
35.8
14.6
15.5
17.1
19.2
20.0
20.0
22.1
25.3
26.3
28.6
30.7
31.4
36.7
40.3

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.3
1.3
1.4
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.7
1.9
2.0
1.3
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
1.4
1.4
1.5
1.5
1.6
1.6
1.6
1.8
1.8
1.8
1.9
2.0
2.2
2.3
1.4
1.5
1.5
1.6
1.7
1.7
1.7
1.9
1.9
2.0
2.1
2.1
2.3
2.5

mm

14.9
15.5
16.8
18.3
18.8
18.8
20.4
22.8
23.6
24.5
26.2
26.7
30.8
34.0
15.6
16.3
17.6
19.2
20.0
20.0
21.5
24.1
25.1
26.2
28.0
28.5
33.7
36.7
17.5
18.3
19.9
21.8
22.7
22.7
24.5
27.8
28.7
30.0
32.1
33.7
39.2
42.3
18.9
20.0
21.6
23.9
24.9
24.9
27.0
30.6
31.6
34.1
36.8
37.5
43.2
47.2

mm

0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.3
0.8
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
0.8
0.8
0.9
1.0
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.5
1.6
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.7

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

340
390
460
530
570
600
680
810
900
990
1,100
1,210
1,500
1,930
380
440
510
590
660
700
780
930
1,050
1,160
1,300
1,430
1,870
2,370
450
530
630
730
810
870
970
1,180
1,310
1,460
1,630
1,920
2,460
3,020
540
640
760
900
1,010
1,090
1,220
1,490
1,670
1,970
2,290
2,550
3,150
3,990

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

mm2

EA

mm

2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.4
1.6

mm

11.5
12.3
13.5
15.0
17.0
17.0
18.2
20.6
21.9
22.9
24.3
26.3
30.1
34.5
12.3
13.0
14.4
16.0
18.1
18.1
19.4
22.0
23.4
24.4
26.0
28.9
32.1
36.9
14.2
15.1
16.7
18.6
21.1
21.1
22.7
25.9
28.2
29.5
31.4
34.0
37.7
43.8
15.8
16.8
18.6
20.8
23.6
23.6
25.4
29.8
31.6
33.0
35.2
38.5
42.7
49.7

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
1.9
2.1
2.2
1.3
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.2
2.3
1.4
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.0
2.1
2.2
2.4
2.6
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.6
2.9

mm

15.6
16.4
17.8
19.5
21.5
21.5
22.9
25.5
26.8
28.0
29.4
31.6
36.2
40.8
16.4
17.3
18.7
20.5
22.8
22.8
24.1
26.9
28.5
29.5
31.3
34.4
38.4
43.4
18.5
19.6
21.2
23.3
26.0
26.0
27.8
31.2
33.7
35.0
37.5
40.3
44.4
50.9
20.3
21.3
23.3
25.7
28.7
28.7
30.7
35.3
37.7
39.3
41.7
45.2
49.8
57.4

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

mm

/km

-km

V/5min.

kg/km

0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.2
1.4
1.5
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.2
1.3
1.5
1.6
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.6
1.8
0.9
0.9
1.0
1.1
1.2
1.2
1.2
1.4
1.4
1.5
1.6
1.7
1.8
2.0

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

380
450
530
620
710
760
840
1,010
1,130
1,260
1,390
1,590
2,100
2,630
430
510
600
700
820
880
970
1,160
1,320
1,460
1,630
1,960
2,470
3,100
520
630
740
880
1,030
1,110
1,240
1,490
1,790
1,980
2,300
2,630
3,180
4,110
640
770
930
1,110
1,300
1,410
1,580
2,010
2,380
2,670
2,980
3,490
4,230
5,530

Offshore Cable

LV Power & Lighting Cable

No.

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering

Instrumentation &
Communication Cable

Max.
overall
dia.

Earthing & Bonding wire

Max.
No. of
wires

VFD Cable

Conductor
Nominal
Area

Technical Information

No. of
Triads

HV Power Cable

250V RFOU(i&c), 250V RFCU(i&c), 250V RFBU(i&c)

45

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable

Cable Designation (S14)


250V BU(c)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &

IEC 60332-3 Category A

250V BU(c)

- Fire resistance

: IEC 60331-21(90min)

IEC 60331-1,-2(120min)

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Construction
Sectional view

Classification

Code

Conductor
Fire resisting layer
Insulation

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

Twisting

- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad
- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core


- A Filler may be applied to obtain a circular Cable

Collective screen

(c)

Sheath

- CU/PS or AL/PS tape + Tinned copper drain wire


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note. Flexible cable (Class5 Conductor) can be supplied

46

Offshore Cable

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

EA

mm

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.0
1.2
1.2
1.2
1.3
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.6
1.7
1.9
1.0
1.2
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
2.0
1.1
1.3
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.2
1.1
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.3

Overall diameter
Nominal

Tolerance

mm

mm

7.6
11.6
12.4
13.2
15.0
16.0
16.0
17.2
19.5
20.3
21.1
22.8
23.9
27.2
31.4
8.0
12.3
13.2
14.2
15.9
17.2
17.2
18.3
20.8
21.6
22.6
24.3
25.6
29.4
33.7
9.2
14.2
15.2
16.2
18.4
19.9
19.9
21.2
24.1
25.3
26.2
28.4
29.9
34.3
39.3
10.0
15.6
16.9
18.0
20.4
21.9
21.9
23.6
26.7
28.1
29.4
31.8
33.5
38.1
43.7

0.5
0.6
0.7
0.7
0.8
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.2
0.5
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
0.6
0.7
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.5
0.6
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.3
1.3
1.4
1.6

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

90
170
200
240
290
330
360
410
500
570
630
720
820
1,020
1,360
100
190
230
280
340
390
430
470
580
660
760
850
980
1,240
1,620
130
240
300
360
440
520
560
630
770
900
1,010
1,150
1,330
1,680
2,190
160
300
390
470
580
660
730
830
1,030
1,200
1,370
1,560
1,810
2,250
2,940

Offshore Cable

LV Power & Lighting Cable

mm2

Thickness
of
Insulation

Instrumentation &
Communication Cable

Max.
overall
dia.

Earthing & Bonding wire

1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

Max.
No. of
wires

VFD Cable

No.

Conductor
Nominal
Area

Technical Information

No. of
Pairs

HV Power Cable

250V BU(c)

47

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V BU(c)
No. of
Triads

No.

1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

48

Conductor
Nominal
Area

Max.
No. of
wires

mm2

EA

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Offshore Cable

Max.
overall
dia.
mm

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
Insulation

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.0
1.2
1.2
1.3
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.8
2.0
2.1
1.1
1.2
1.3
1.3
1.4
1.5
1.5
1.5
1.7
1.7
1.8
1.8
1.9
2.1
2.3
1.1
1.4
1.4
1.5
1.6
1.7
1.7
1.7
1.9
1.9
2.0
2.1
2.2
2.3
2.6
1.1
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.1
2.1
2.3
2.4
2.7

Overall diameter
Nominal

Tolerance

mm

mm

8.0
12.7
13.5
15.0
16.5
18.8
18.8
20.3
23.1
24.4
25.6
27.2
29.7
33.2
38.1
8.7
13.6
14.6
16.0
17.9
20.4
20.4
21.8
25.0
26.4
27.8
29.7
32.2
35.9
41.4
9.8
17.1
18.1
20.0
22.2
25.0
25.0
26.7
30.7
32.3
33.9
36.5
39.4
43.6
50.2
10.6
17.3
18.4
20.5
22.9
26.1
26.1
28.1
32.2
34.3
36.0
38.2
41.6
46.2
53.5

0.5
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.3
1.4
0.6
0.7
0.7
0.8
0.8
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.5
0.6
0.8
0.8
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8
0.6
0.8
0.9
0.9
1.0
1.1
1.1
1.1
1.3
1.3
1.4
1.4
1.5
1.7
1.9

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

110
200
250
320
380
460
500
570
700
800
920
1,020
1,220
1,520
1,960
130
230
300
370
450
540
600
660
830
960
1,090
1,240
1,450
1,810
2,360
160
330
410
520
630
750
820
920
1,170
1,330
1,520
1,730
2,020
2,480
3,260
200
390
510
650
790
950
1,050
1,200
1,500
1,750
2,010
2,250
2,660
3,290
4,340

Instrumentation & Communication Cable

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Cable Designation (S13)


LV Power & Lighting Cable

250V BU(i)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &

IEC 60332-3 Category A


: IEC 60331-21(90min)

IEC 60331-1,-2(120min)

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

250V BU(i)

- Fire resistance

Sectional view

Classification

Code

Conductor
Fire resisting layer
Insulation

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

Twisting
Individual screen

Earthing & Bonding wire

Construction

- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad

(i)

- CU/PS or AL/PS tape + Tinned copper drain wire


- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core

Sheath

VFD Cable

- A Filler may be applied to obtain a circular Cable


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color
Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape

Technical Information

Note. Flexible cable (Class5 Conductor) can be supplied

Offshore Cable

49

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V BU(i)
No. of
Pairs

No.

1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

50

Conductor
Nominal
Area

Max.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
Insulation

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.0
1.2
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.8
1.9
1.0
1.2
1.2
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.7
1.9
2.0
1.1
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
1.9
2.1
2.2
1.1
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.0
2.3
2.4

Overall diameter
Nominal

Tolerance

mm

mm

7.6
12.3
13.0
14.5
16.1
16.9
16.9
18.5
21.2
22.2
23.3
25.2
25.7
30.2
32.9
8.0
13.0
13.8
15.3
17.3
17.9
17.9
19.8
22.7
23.6
24.9
26.7
27.3
32.3
35.2
9.2
15.0
15.9
17.6
19.9
20.6
20.6
22.8
26.1
27.2
28.7
31.2
31.9
37.5
40.8
10.0
16.4
17.6
19.5
21.8
22.8
22.8
25.3
29.1
30.5
32.0
34.5
35.3
41.7
45.3

0.5
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.3
0.5
0.7
0.7
0.8
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.3
1.4
0.6
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.5
0.6
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.4
1.6
1.7

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

90
180
230
290
340
400
430
490
610
710
800
910
1,030
1,320
1,680
100
200
260
330
410
460
510
590
730
830
960
1,070
1,230
1,580
2,030
130
260
330
420
520
590
650
750
930
1,070
1,230
1,420
1,620
2,060
2,630
160
320
430
540
660
770
850
980
1,230
1,440
1,640
1,860
2,130
2,740
3,510

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

EA

mm

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.0
1.2
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.2
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.3
1.1
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.3
2.6
1.1
1.4
1.4
1.5
1.6
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.3
2.5
2.8

Overall diameter
Nominal

Tolerance

mm

mm

8.0
13.1
14.1
15.5
17.3
19.7
19.7
21.1
24.0
25.6
26.7
28.6
31.2
34.6
40.0
8.7
14.2
15.1
16.8
18.5
21.1
21.1
22.8
26.0
27.7
29.0
31.0
33.6
37.4
43.1
9.8
16.1
17.4
19.1
21.4
24.4
24.4
26.3
30.2
32.1
33.7
36.0
39.0
43.4
50.2
10.6
17.7
18.9
21.0
23.5
26.8
26.8
29.1
33.4
35.3
37.1
39.6
42.9
47.9
55.4

0.5
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.5
0.6
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.6
0.6
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8
0.6
0.8
0.9
0.9
1.0
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.6
1.7
2.0

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

110
220
290
350
430
520
580
640
800
940
1,060
1,200
1,430
1,770
2,320
130
260
330
420
510
610
680
770
960
1,130
1,290
1,470
1,720
2,130
2,790
160
320
430
530
660
790
880
1,000
1,260
1,480
1,700
1,930
2,260
2,790
3,700
200
410
550
700
860
1,040
1,160
1,340
1,680
1,950
2,240
2,550
2,990
3,740
4,940

Offshore Cable

LV Power & Lighting Cable

mm2

Thickness
of
Insulation

Instrumentation &
Communication Cable

Max.
overall
dia.

Earthing & Bonding wire

1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

Max.
No. of
wires

VFD Cable

No.

Conductor
Nominal
Area

Technical Information

No. of
Triads

HV Power Cable

250V BU(i)

51

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable

Cable Designation
250V BU(i&c)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &

IEC 60332-3 Category A

250V BU(i&c)

- Fire resistance

: IEC 60331-21(90min)

IEC 60331-1,-2(120min)

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Construction
Sectional view

Classification

Code

Conductor
Fire resisting layer
Insulation

Twisting
Individual screen

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad

(i)

- CU/PS or AL/PS tape + Tinned copper drain wire


- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core


- A Filler may be applied to obtain a circular Cable

Collective screen

(c)

Sheath

- CU/PS or AL/PS tape + Tinned copper drain wire


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note. Flexible cable (Class5 Conductor) can be supplied

52

Offshore Cable

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

EA

mm

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.2
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.9
2.0
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.8
1.9
2.0
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
1.9
2.1
2.2
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.0
2.3
2.4

Overall diameter
Nominal

Tolerance

mm

mm

12.4
13.1
14.6
16.2
17.0
17.0
18.6
21.3
22.3
23.4
25.3
25.8
30.5
33.2
13.1
14.1
15.4
17.4
18.0
18.0
19.9
22.8
23.7
25.0
26.8
27.6
32.4
35.3
15.1
16.0
17.7
20.0
20.7
20.7
22.9
26.2
27.3
29.0
31.3
32.0
37.6
40.9
16.5
17.7
19.6
21.9
22.9
22.9
25.4
29.2
30.6
32.1
34.6
35.4
41.8
45.4

0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.3
0.7
0.7
0.8
0.8
0.8
0.8
0.9
1.0
1.0
1.1
1.1
1.1
1.3
1.4
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.5
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.4
1.6
1.7

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

190
240
300
360
410
450
510
630
730
820
940
1,060
1,370
1,740
220
290
350
430
480
530
610
750
860
980
1,100
1,270
1,620
2,060
280
350
440
540
610
670
770
960
1,100
1,280
1,450
1,650
2,090
2,670
340
450
570
680
790
880
1,010
1,270
1,480
1,670
1,900
2,170
2,780
3,560

Offshore Cable

LV Power & Lighting Cable

mm2

Thickness
of
Insulation

Instrumentation &
Communication Cable

Max.
overall
dia.

Earthing & Bonding wire

2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

Max.
No. of
wires

VFD Cable

No.

Conductor
Nominal
Area

Technical Information

No. of
Pairs

HV Power Cable

250V BU(i&c)

53

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V BU(i&c)
No. of
Triads

No.

2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

54

Conductor
Nominal
Area

Max.
No. of
wires

mm2

EA

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

Offshore Cable

Max.
overall
dia.
mm

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness
of
Insulation

Thickness
of
sheath

mm

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.2
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.2
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.3
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.2
2.3
2.6
1.4
1.4
1.5
1.6
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.3
2.5
2.8

Overall diameter
Nominal

Tolerance

mm

mm

13.2
14.2
15.6
17.4
19.8
19.8
21.2
24.1
25.7
26.8
28.7
31.3
34.7
40.1
14.3
15.2
16.9
18.6
21.2
21.2
22.9
26.1
27.8
29.1
31.1
33.7
37.5
43.2
16.2
17.5
19.2
21.5
24.5
24.5
26.4
30.5
32.2
33.8
36.1
39.1
43.5
50.3
17.8
19.0
21.1
23.6
26.9
26.9
29.2
33.5
35.4
37.2
39.7
43.0
48.0
55.5

0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.5
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.6
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8
0.8
0.9
0.9
1.0
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.6
1.7
2.0

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

310
380
460
550
650
700
780
950
1,100
1,220
1,380
1,610
2,050
2,630
280
350
440
530
640
700
800
990
1,160
1,320
1,500
1,760
2,160
2,830
340
450
560
680
820
910
1,030
1,310
1,510
1,730
1,960
2,300
2,830
3,740
440
570
730
890
1,070
1,190
1,370
1,720
1,990
2,280
2,590
3,030
3,780
4,990

Instrumentation & Communication Cable

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Cable Designation (S4, S4/S8)


LV Power & Lighting Cable

250V BFOU(c), BFCU(c), BFBU(c)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &

IEC 60332-3 Category A

- Fire resistance

: IEC 60331-21(90min)
IEC 60331-1,-2(120min)

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

250V BFOU(c)

Sectional view

Classification

Code

Conductor
Fire resisting layer
Insulation

Earthing & Bonding wire

Construction
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
B

Twisting

- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad
- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core

Collective screen

(c)

- CU/PS or AL/PS tape + Tinned copper drain wire

Inner covering

- Flame retardant halogen free thermoset compound

- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)

Armor
Sheath

(B,C)
U

VFD Cable

- A Filler may be applied to obtain a circular Cable

- A suitable separator tape(s) may be applied under/over the armor


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color
Pair : Black, Light blue

Triad : Black, Light blue, Brown

Technical Information

Core identification

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note. Flexible cable (Class5 Conductor) can be supplied

Offshore Cable

55

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V BFOU(c), 250V BFCU(c), 250V BFBU(c)
No. of
Pairs

Conductor
Nominal
Area

Max.
No. of
wires

Max.
overall
dia.

No.

mm2

EA

mm

1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

56

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4

mm

7.4
11.0
11.8
12.6
14.2
15.2
15.2
16.2
18.3
19.1
19.9
21.4
22.5
25.6
30.0
7.8
11.7
12.6
13.4
15.1
16.2
16.2
17.3
19.6
20.4
21.2
22.9
24.0
28.2
32.1
8.8
13.4
14.4
15.4
17.4
18.7
18.7
20.0
22.7
23.7
24.6
26.6
28.7
32.7
37.3
9.6
14.8
15.9
17.0
19.2
20.7
20.7
22.2
25.1
26.3
28.2
30.4
31.9
36.3
41.9

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.6
1.6
1.7
1.8
1.9
2.1
1.2
1.3
1.4
1.4
1.5
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.2
1.2
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.8
1.9
2.0
2.2
2.4
1.2
1.4
1.5
1.5
1.6
1.7
1.7
1.7
1.9
1.9
2.0
2.1
2.1
2.3
2.5

mm

11.1
15.1
15.9
16.9
18.5
19.7
19.7
20.7
23.0
23.8
24.6
26.3
27.6
30.9
35.7
11.7
15.8
16.9
17.7
19.6
20.7
20.7
21.8
24.3
25.3
26.1
28.0
29.1
33.7
38.4
12.7
17.7
18.7
19.9
21.9
23.4
23.4
24.9
27.8
28.8
29.7
31.9
34.2
39.0
44.0
13.5
19.1
20.4
21.5
23.9
25.6
25.6
27.1
30.4
31.6
33.7
36.5
38.0
42.8
48.8

mm

0.6
0.8
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.4
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.1
1.2
1.3
1.5
0.7
0.8
0.9
0.9
1.0
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.5
1.6
0.7
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.8

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

210
340
390
440
510
570
600
650
770
850
920
1,030
1,150
1,390
1,840
240
370
430
490
570
630
670
730
870
970
1,060
1,180
1,310
1,700
2,220
270
450
520
600
700
790
840
930
1,110
1,230
1,350
1,510
1,800
2,290
2,870
320
520
630
720
860
970
1,040
1,150
1,390
1,560
1,830
2,130
2,390
2,920
3,750

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

mm2

EA

mm

1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.4
1.6

mm

7.8
12.1
12.9
14.2
15.7
17.8
17.8
19.1
21.7
23.0
24.0
25.6
28.5
31.6
36.3
8.3
13.0
13.8
15.2
16.9
19.2
19.2
20.6
23.4
24.8
26.0
28.5
30.8
34.1
39.6
9.4
14.9
15.9
17.6
19.6
22.2
22.2
23.9
28.1
29.7
31.1
33.1
35.8
40.2
46.2
10.2
16.3
17.4
19.3
21.5
24.5
24.5
26.3
30.8
32.7
34.2
36.4
39.8
44.2
51.5

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.2
1.3
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.3
1.2
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.5
1.2
1.4
1.5
1.6
1.6
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.3
2.5
2.7
1.3
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.1
2.2
2.2
2.3
2.5
2.6
2.9

mm

11.7
16.2
17.2
18.5
20.2
22.5
22.5
23.8
26.6
28.1
29.1
30.9
34.0
37.7
42.8
12.2
17.3
18.1
19.7
21.4
23.9
23.9
25.5
28.5
29.9
31.3
34.0
36.9
40.4
46.5
13.3
19.2
20.4
22.3
24.3
27.1
27.1
29.0
33.6
35.2
37.2
39.4
42.3
47.1
53.5
14.3
20.8
21.9
24.0
26.4
29.6
29.6
31.6
36.9
39.0
40.5
42.9
46.7
51.3
59.2

mm

0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.6
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.2
1.2
1.3
1.4
1.5
1.7
0.7
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.6
1.7
1.9
0.7
0.9
1.0
1.0
1.1
1.2
1.2
1.2
1.4
1.5
1.5
1.6
1.7
1.8
2.1

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

240
390
460
540
620
730
770
850
1,010
1,140
1,250
1,390
1,680
2,090
2,620
270
440
510
610
700
820
870
970
1,160
1,300
1,450
1,710
2,030
2,420
3,130
310
530
640
760
880
1,030
1,100
1,230
1,590
1,780
2,070
2,300
2,620
3,230
4,070
370
640
770
930
1,100
1,290
1,390
1,560
2,080
2,360
2,620
2,920
3,430
4,130
5,400

Offshore Cable

LV Power & Lighting Cable

No.

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering

Instrumentation &
Communication Cable

Max.
overall
dia.

Earthing & Bonding wire

Max.
No. of
wires

VFD Cable

Conductor
Nominal
Area

Technical Information

No. of
Triads

HV Power Cable

250V BFOU(c), 250V BFCU(c), 250V BFBU(c)

57

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable

Cable Designation (S3, S3/S7)


250V BFOU(i), BFCU(i), BFBU(i)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &

IEC 60332-3 Category A

250V BFOU(i)

- Fire resistance

: IEC 60331-21(90min)

IEC 60331-1,-2(120min)

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Construction
Sectional view

Classification

Code

Conductor
Fire resisting layer
Insulation

Twisting
Individual screen

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad

(i)

- CU/PS or AL/PS tape + Tinned copper drain wire


- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core


- A Filler may be applied to obtain a circular Cable

Inner covering
Armor
Sheath

- Flame retardant halogen free thermoset compound

- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)

(B,C)
U

- A suitable separator tape(s) may be applied under/over the armor


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note. Flexible cable (Class5 Conductor) can be supplied

58

Offshore Cable

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

mm2

EA

mm

1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4

mm

7.4
11.7
12.4
13.7
15.3
15.9
15.9
17.5
20.0
20.8
21.9
23.6
24.1
29.0
31.5
7.8
12.4
13.2
14.5
16.3
16.9
16.9
18.6
21.3
22.2
23.3
25.1
25.7
30.9
33.6
8.8
14.2
15.1
16.6
18.7
19.4
19.4
21.4
24.5
25.6
26.9
29.8
30.5
35.7
39.2
9.6
15.6
16.6
18.3
20.6
21.4
21.4
23.7
27.9
29.1
30.6
32.9
33.7
39.9
43.3

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.1
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.7
1.8
1.8
2.0
2.1
1.2
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
1.9
2.1
2.2
1.2
1.4
1.5
1.5
1.6
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.1
2.3
2.4
1.2
1.5
1.5
1.6
1.7
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.2
2.5
2.6

mm

11.1
15.8
16.5
18.0
19.8
20.4
20.4
22.2
24.9
25.7
26.8
28.7
29.2
34.5
37.6
11.7
16.5
17.5
18.8
20.8
21.4
21.4
23.3
26.2
27.1
28.4
30.4
31.0
37.0
39.9
12.7
18.5
19.6
21.1
23.4
24.1
24.1
26.3
29.6
30.9
32.2
35.3
36.6
42.2
45.9
13.5
20.1
21.1
23.0
25.5
26.3
26.3
28.8
33.4
34.6
36.7
39.2
40.0
46.8
50.4

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

mm

/km

-km

V/5min.

kg/km

0.6
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.2
1.3
1.4
0.7
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.2
1.4
1.5
0.7
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.7
0.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.5
1.7
1.8

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

220
360
420
490
580
630
670
760
910
1,000
1,110
1,240
1,370
1,790
2,280
240
400
470
550
650
710
760
860
1,030
1,150
1,280
1,440
1,600
2,170
2,650
280
480
570
670
790
870
930
1,050
1,270
1,440
1,590
1,880
2,190
2,710
3,390
320
560
670
810
970
1,070
1,160
1,310
1,690
1,900
2,210
2,480
2,760
3,510
4,340

Offshore Cable

LV Power & Lighting Cable

No.

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering

Instrumentation &
Communication Cable

Max.
overall
dia.

Earthing & Bonding wire

Max.
No. of
wires

VFD Cable

Conductor
Nominal
Area

Technical Information

No. of
Pairs

HV Power Cable

250V BFOU(i), 250V BFCU(i), 250V BFBU(i)

59

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V BFOU(i), 250V BFCU(i), 250V BFBU(i)
No. of
Triads

Conductor
Nominal
Area

Max.
No. of
wires

Max.
overall
dia.

No.

mm2

EA

mm

1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

60

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.6

mm

7.8
12.5
13.3
14.7
16.3
18.5
18.5
19.9
22.6
24.0
25.1
26.8
29.8
33.0
38.4
8.3
13.4
14.3
15.8
17.5
19.9
19.9
21.4
24.4
25.9
27.0
29.6
32.0
35.6
41.3
9.4
15.3
16.4
18.1
20.2
23.0
23.0
24.7
29.0
30.7
32.1
34.2
37.0
41.6
47.8
10.2
16.7
17.9
19.8
22.1
25.2
25.2
27.9
31.8
33.7
35.3
37.6
41.1
45.7
53.2

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.2
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.8
1.8
1.9
1.9
2.0
2.2
2.4
1.2
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.1
2.3
2.5
1.2
1.5
1.5
1.6
1.7
1.8
1.8
1.8
2.0
2.1
2.2
2.2
2.3
2.5
2.8
1.3
1.5
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.7
3.0

mm

11.7
16.8
17.6
19.0
20.8
23.2
23.2
24.6
27.7
29.1
30.4
32.1
35.3
39.3
45.1
12.2
17.7
18.6
20.3
22.2
24.6
24.6
26.3
29.5
31.2
32.3
35.1
38.1
42.1
48.2
13.3
19.8
20.9
22.8
25.1
28.1
28.1
29.8
34.5
36.8
38.4
40.5
43.5
48.5
55.3
14.3
21.2
22.6
24.5
27.0
30.5
30.5
33.4
37.9
40.0
41.8
44.3
48.0
53.0
61.1

mm

0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.7
0.7
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.7
0.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.5
1.5
1.6
1.8
2.0
0.7
0.9
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.6
1.7
1.9
2.1

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

240
420
490
570
680
790
840
930
1,130
1,270
1,420
1,570
1,900
2,380
3,080
270
460
550
660
780
900
960
1,080
1,300
1,480
1,640
1,930
2,300
2,780
3,590
310
560
670
810
960
1,130
1,220
1,350
1,730
2,060
2,300
2,540
2,910
3,600
4,590
370
660
820
990
1,180
1,400
1,520
1,800
2,260
2,580
2,890
3,230
3,780
4,600
6,020

Instrumentation & Communication Cable

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Cable Designation
LV Power & Lighting Cable

250V BFOU(i&c), BFCU(i&c), BFBU(i&c)

Application Standard
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &

IEC 60332-3 Category A


: IEC 60331-21(90min)

IEC 60331-1,-2(120min)

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

250V BFOU(i&c)

- Fire resistance

Sectional view

Classification

Code

Conductor
Fire resisting layer
Insulation

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

Twisting
Individual screen

Earthing & Bonding wire

Construction

- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad

(i)

- CU/PS or AL/PS tape + Tinned copper drain wire


- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core

VFD Cable

- A Filler may be applied to obtain a circular Cable


Collective screen

(c)

- CU/PS or AL/PS tape + Tinned copper drain wire

Inner covering

- Flame retardant halogen free thermoset compound

- Braid of tinned copper wire (O) / bronze wire (B) / galvanized steel wire (C)

Armor
Sheath

(B,C)
U

- A suitable separator tape(s) may be applied under / over the armor


- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
Pair : Black, Light blue

Technical Information

- Each Pair / Triad : Core color


Core identification

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note. Flexible cable (Class5 Conductor) can be supplied

Offshore Cable

61

Halogen free & Mud resistant Offshore cable

Instrumentation & Communication Cable


250V BFOU(i&c), 250V BFCU(i&c), 250V BFBU(i&c)
No. of
Pairs

Conductor
Nominal
Area

Max.
No. of
wires

Max.
overall
dia.

No.

mm2

EA

mm

2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

62

Offshore Cable

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4

mm

11.8
12.5
13.8
15.4
16.0
16.0
17.6
20.1
20.9
22.0
23.7
24.2
29.1
31.6
12.5
13.3
14.6
16.4
17.0
17.0
18.7
21.4
22.3
23.4
25.2
25.8
31.0
33.7
14.3
15.2
16.7
18.8
19.5
19.5
21.5
24.6
25.7
27.0
29.9
30.6
35.8
39.3
15.7
16.7
18.4
20.7
21.5
21.5
23.8
28.0
29.2
30.7
33.0
33.8
40.0
43.4

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.7
1.8
1.8
2.0
2.1
1.4
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
1.9
2.1
2.2
1.4
1.5
1.5
1.6
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.1
2.3
2.4
1.5
1.5
1.6
1.7
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.2
2.5
2.6

mm

15.9
16.8
18.1
19.9
20.5
20.5
22.3
25.0
25.8
26.9
28.8
29.3
34.6
37.7
16.8
17.6
18.9
20.9
21.5
21.5
23.4
26.3
27.2
28.5
30.5
31.1
37.1
40.0
18.6
19.7
21.2
23.5
24.2
24.2
26.4
29.7
31.0
32.3
35.4
36.7
42.3
46.0
20.2
21.2
23.1
25.6
26.4
26.4
28.9
33.5
34.7
36.8
39.3
40.1
46.9
50.5

mm

0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.2
1.3
1.4
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.2
1.4
1.5
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.5
1.7
1.8

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

380
440
510
600
650
690
780
930
1,030
1,130
1,270
1,400
1,820
2,310
420
490
570
670
730
780
880
1,060
1,170
1,310
1,470
1,630
2,200
2,690
500
590
690
810
890
950
1,080
1,300
1,470
1,630
1,920
2,230
2,750
3,440
590
700
840
990
1,100
1,180
1,340
1,720
1,930
2,250
2,520
2,800
3,550
4,390

Instrumentation & Communication Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

mm2

EA

mm

2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

mm

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

mm

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.6

mm

12.6
13.4
14.8
16.4
18.6
18.6
20.0
22.7
24.1
25.2
26.9
29.9
33.1
38.5
13.5
14.4
15.9
17.6
20.0
20.0
21.5
24.5
26.0
27.9
29.7
32.1
35.7
41.4
15.4
16.5
18.2
20.3
23.1
23.1
24.8
29.1
30.8
32.2
34.3
37.1
41.7
47.9
16.8
18.0
19.9
22.2
25.3
25.3
28.0
31.9
33.8
35.4
37.7
41.2
45.8
53.3

Dia. of
wire for
armour
mm

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.8
1.9
1.9
2.0
2.2
2.4
1.4
1.4
1.5
1.6
1.7
1.7
1.7
1.8
1.9
2.0
2.0
2.2
2.3
2.5
1.5
1.5
1.6
1.7
1.8
1.8
1.8
2.0
2.1
2.2
2.2
2.4
2.5
2.8
1.5
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.7
3.0

mm

16.9
17.7
19.1
20.9
23.3
23.3
24.9
27.8
29.2
30.5
32.2
35.4
39.4
45.2
17.8
18.7
20.4
22.3
24.9
24.9
26.4
29.6
31.3
33.4
35.2
38.4
42.2
48.3
19.9
21.0
22.9
25.2
28.2
28.2
29.9
34.6
36.9
38.5
40.6
43.8
48.6
55.4
21.3
22.7
24.6
27.1
30.6
30.6
33.5
38.0
40.1
41.9
44.4
48.1
53.1
61.2

mm

0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.7
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.5
1.5
1.6
1.8
2.0
0.9
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.6
1.7
1.9
2.1

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight
Approx.

/km

-km

V/5min.

kg/km

26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02

1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850

1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500

430
510
590
690
810
870
970
1,160
1,300
1,450
1,600
1,930
2,420
3,110
480
570
680
800
940
1,000
1,110
1,330
1,510
1,780
1,960
2,350
2,820
3,630
580
690
830
990
1,160
1,250
1,380
1,770
2,090
2,330
2,580
2,970
3,640
4,640
680
850
1,010
1,200
1,430
1,560
1,830
2,290
2,620
2,930
3,270
3,830
4,650
6,080

Offshore Cable

LV Power & Lighting Cable

No.

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering

Instrumentation &
Communication Cable

Max.
overall
dia.

Earthing & Bonding wire

Max.
No. of
wires

VFD Cable

Conductor
Nominal
Area

Technical Information

No. of
Triads

HV Power Cable

250V BFOU(i&c), 250V BFCU(i&c), 250V BFBU(i&c)

63

Earthing & Bonding wire

0.6/1kV UX, FX - UX
0.6/1kV RX

65 ~ 66

Earthing & Bonding wire

Earthing & Bonding wire

HV Power Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Cable Designation (P15)


LV Power & Lighting Cable

0.6/1kV UX, FX - UX , RX

Application Standard
- Design guide

: NEK-606 & IEC 60092-353

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

0.6/1KV RX

Construction
Classification

Code

Construction detail

Conductor

Stranded tinned annealed copper wires as per IEC 60228, Class 2

Insulation

RX

HF EPR as per IEC 60092-351

UX

SHF2 as per IEC 60092-359

Earthing & Bonding wire

Sectional view

Insulation color : Yellow/Green (Green base with yellow strip) or Green

No.

Conductor
Nominal
Area

Min.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

7
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61

1.4
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1

Thickness
of
Insulation
mm

2.0
2.0
2.0
2.0
2.0
2.0
2.1
2.4
2.4
2.7
3.0
3.0
3.1
3.4
3.7
4.0
4.3

Overall diameter
Nominal

Tolerance

mm

mm

5.5
5.8
6.2
6.7
7.3
8.2
9.4
11.3
12.4
14.4
16.7
18.6
20.3
22.4
24.9
28.1
31.0

0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.8
0.8
0.9
1.0
1.0
1.1
1.2
1.3
1.4
1.5

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight

/km

-km

V/5min.

kg/km

18.2
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607

22
20
18
15
13
11
10
9
8
8
7
6
6
6
6
5
5

3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500

50
58
71
89
114
160
230
350
450
600
840
1,110
1,360
1,660
2,080
2,690
3,330

Offshore Cable

Technical Information

No. of
Cores

VFD Cable

0.6/1kV UX (CLASS2 CONDUCTOR)

65

Halogen free & Mud resistant Offshore cable

Earthing & Bonding wire


0.6/1kV FX-UX (CLASS5 CONDUCTOR)
No. of
Cores

No.

Conductor
Nominal
Area

Min.
No. of
wires

Max.
overall
dia.

mm2

EA

mm

1.0

0.21

Thickness
of
Insulation
mm

1.5

Overall diameter
Nominal

Tolerance

mm

mm

2.0

5.5

0.5

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight

/km

-km

V/5min.

kg/km

20.0

22

3,500

50

1.5

0.26

1.8

2.0

5.8

0.5

13.7

20

3,500

58

2.5

0.26

2.4

2.0

6.3

0.6

8.21

17

3,500

72

0.31

3.0

2.0

6.8

0.6

5.09

15

3,500

91

0.31

3.9

2.0

7.4

0.6

3.39

13

3,500

115

10

0.41

5.1

2.0

8.3

0.6

1.95

11

3,500

160

16

0.41

6.3

2.1

10.0

0.7

1.24

3,500

230

25

0.41

7.8

2.4

12.1

0.8

0.795

3,500

340

35

0.41

9.2

2.4

13.3

0.8

0.565

3,500

450

50

0.41

11.0

2.7

15.5

0.9

0.393

3,500

630

70

0.51

13.1

3.0

18.0

1.0

0.277

3,500

880

95

0.51

15.1

3.1

19.9

1.1

0.210

3,500

1,110

120

0.51

17.0

3.1

21.7

1.2

0.164

3,500

1,370

150

0.51

19.0

3.4

24.1

1.3

0.132

3,500

1,710

185

0.51

21.0

3.7

26.2

1.3

0.108

3,500

2,060

240

0.51

24.0

4.0

29.5

1.5

0.0817

3,500

2,680

300

0.51

27.0

4.3

32.7

1.6

0.0654

3,500

3,360

Conductor
Resistance
(at 20)
(Max.)

Insulation
Resistance
(at 20)
(Min.)

Test
Voltage

Cable
Weight

/km

-km

V/5min.

kg/km

0.6/1kV RX
No. of
Cores

No.

66

Conductor
Nominal
Area

Min.
No. of
wires

mm2

EA

Max.
overall
dia.
mm

Thickness
of
Insulation
mm

Overall diameter
Nominal

Tolerance

mm

mm

1.0

1.4

2.0

5.5

0.5

18.2

22

3,500

47

1.5

1.7

2.0

5.8

0.5

12.2

20

3,500

54

2.5

2.2

2.0

6.2

0.5

7.56

18

3,500

67

2.7

2.0

6.7

0.6

4.70

15

3,500

85

3.3

2.0

7.3

0.6

3.11

13

3,500

109

10

4.2

2.0

8.2

0.6

1.84

11

3,500

150

16

5.3

2.1

9.4

0.7

1.16

10

3,500

220

25

6.6

2.3

11.1

0.7

0.734

3,500

330

35

7.9

2.4

12.4

0.8

0.529

3,500

440

50

19

9.1

2.7

14.4

0.9

0.391

3,500

590

70

19

11.0

2.9

16.5

1.0

0.270

3,500

810

95

19

12.9

3.0

18.6

1.0

0.195

3,500

1,090

120

37

14.5

3.1

20.3

1.1

0.154

3,500

1,340

150

37

16.2

3.4

22.4

1.2

0.126

3,500

1,630

185

37

18.0

3.7

24.9

1.3

0.100

3,500

203

240

61

20.6

4.0

28.1

1.4

0.0762

3,500

2,640

300

61

23.1

4.3

31.0

1.5

0.0607

3,500

3,270

Offshore Cable

VFD Cable

0.6/1kV(1.8/3kV) RFOU(VFD), FX-RFOU(VFD)

68 ~ 69

0.6/1kV(1.8/3kV) BFOU(VFD), FX-BFOU(VFD)

70 ~ 71

Halogen free & Mud resistant Offshore cable

VFD Cable

Cable Designation
0.6/1kV(1.8/3kV) RFOU(VFD), FX-RFOU(VFD)

Application Standard
- Design guide

: NEK-606 & IEC 60092-353

- Flame retardant

: IEC 60332-1 &

0.6/1kV(1.8/3kV)
RFOU(VFD)

IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Construction
Sectional view

Classification

Code

Conductor
Insulation

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

- HF EPR as per IEC 60092-351


- Insulated cores shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core


- A Filler may be applied to obtain a circular Cable

Inner covering

F
(VFD)

Armor (Screen)

- Flame retardant halogen free thermoset compound


- CU/PS tape
- Braid of tinned copper wire

- Coverage density of braid shall be not less than 100%.


- A suitable separator tape(s) may be applied over the armor

Sheath
Core identification
Note. 1. Flexible cable (Class5 Conductor) can be supplied

2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)

68

Offshore Cable

- SHF2 or SHF Mud as per IEC 60092-359


- Outer sheath color : Black
- 3C+3E : Off-white, Black, Red +G/Y

VFD Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

0.6/1kV(1.8/3kV) RFOU(VFD)

mm2

25
6
35
6
50
10
70
16
95
16
120
25
150
25
185
35
240
50

ea.

7
7
7
7
19
7
19
7
19
7
37
7
37
7
37
7
61
19

mm

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

6.6
3.3
7.9
3.3
9.1
4.2
11.0
5.3
12.9
5.3
14.5
6.6
16.2
6.6
18.0
7.9
20.6
9.1

2.2
1.0
2.2
1.0
2.2
1.0
2.2
1.0
2.4
1.0
2.4
1.2
2.4
1.2
2.4
1.2
2.4
1.4

mm

mm

Dia. of
wire for
armour
mm

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

mm

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight

mm

/km

-km

V/5min.

kg/km

1.0

25.7

0.3

1.9

31.7

1.6

28.7

0.3

2.0

34.9

1.7

1.2

31.5

0.4

2.2

38.5

1.8

1.2

35.4

0.4

2.3

42.6

2.0

1.4

40.7

0.4

2.5

48.3

2.2

1.4

44.2

0.4

2.7

52.2

2.4

1.4

47.6

0.4

2.8

55.8

2.5

1.6

51.9

0.4

3.0

60.5

2.7

1.6

57.7

0.4

3.2

66.7

3.0

830
790
730
790
640
640
550
530
510
530
460
510
420
510
380
440
340
440

6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500

1,970

1.2

0.734
3.110
0.529
3.110
0.391
1.840
0.270
1.160
0.195
1.160
0.154
0.734
0.126
0.734
0.1000
0.5290
0.0762
0.3910

HV Power Cable

3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E

Max.
Dia.

2,420
3,160
4,150

LV Power & Lighting Cable

No.

Conductor
Nominal
Min.
Area
Number of
wires

5,330
6,540
7,590
9,230
11,690

Instrumentation &
Communication Cable

No. of
Cores

0.6/1kV(1.8/3kV) FX-RFOU(VFD)

mm2

25
6
35
6
50
10
70
16
95
16
120
25
150
25
185
35
240
50

Max.
overall
dia.

mm

mm

0.41
0.31
0.41
0.31
0.41
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41

7.8
3.9
9.2
3.9
11.0
5.1
13.1
6.3
15.1
6.3
17.0
7.8
19.0
7.8
21.0
9.2
24.0
11.0

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

2.2
1.0
2.2
1.0
2.2
1.0
2.2
1.0
2.4
1.0
2.4
1.2
2.4
1.2
2.4
1.2
2.4
1.4

mm

mm

Dia. of
wire for
armour
mm

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

mm

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight

mm

/km

-km

V/5min.

kg/km

1.2

28.3

0.3

2.0

34.5

1.7

31.3

0.4

2.1

38.1

1.8

1.2

34.7

0.4

2.3

41.9

2.0

1.4

39.2

0.4

2.5

46.8

2.2

1.4

44.0

0.4

2.7

52.0

2.4

1.4

47.8

0.4

2.8

56.0

2.5

1.6

52.1

0.4

3.0

60.7

2.7

1.6

56.2

0.4

3.1

65.0

2.9

1.6

63.1

0.4

3.4

72.5

3.2

750
790
650
790
570
630
490
470
470
470
420
450
380
450
350
390
310
380

6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500

2,140

1.2

0.795
3.390
0.565
3.390
0.393
1.950
0.277
1.240
0.210
1.240
0.164
0.795
0.132
0.795
0.108
0.565
0.0817
0.393

Earthing & Bonding wire

3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E

Max.
dia. of
wires

2,710
3,520
4,550
5,640
6,880
8,120

VFD Cable

No.

Conductor
Nominal
Area

9,620
12,390

Technical Information

No. of
Cores

Offshore Cable

69

Halogen free & Mud resistant Offshore cable

VFD Cable

Cable Designation
0.6/1kV(1.8/3kV) BFOU(VFD), FX-BFOU(VFD)

Application Standard
- Design guide

: NEK-606 & IEC 60092-353

- Flame retardant

: IEC 60332-1 &

IEC 60332-3 Category A

0.6/1kV(1.8/3kV)
BFOU(VFD)

- Fire resistance

: IEC 60331-21(90min)

IEC 60331-1,-2(120min)

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40/-35)

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Construction
Sectional view

Classification

Code

Conductor
Fire resisting layer
Insulation

Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2

- Mica/glass tape
- HF EPR as per IEC 60092-351
- Insulated cores shall be cabled
- Flame retardant & non-hygroscopic fillers may be used

Cabling

- Suitable tape(s) may be applied on the cabled core


- A Filler may be applied to obtain a circular Cable

Inner covering

F
(VFD)

Armor (Screen)

- Flame retardant halogen free thermoset compound


- CU/PS tape
- Braid of tinned copper wire

- Coverage density of braid shall be not less than 100%


- A suitable separator tape(s) may be applied over the armor

Sheath
Core identification
Note. 1. Flexible cable (Class5 Conductor) can be supplied

2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)

70

Offshore Cable

- SHF2 or SHF Mud as per IEC 60092-359


- Outer sheath color : Black
- 3C+3E : Off-white, Black, Red +G/Y

VFD Cable

NEK-606 (2009), IEC 60092-350, 353, 354, 376

0.6/1kV(1.8/3kV) BFOU(VFD)

mm2

25
6
35
6
50
10
70
16
95
16
120
25
150
25
185
35
240
50

ea.

7
7
7
7
19
7
19
7
19
7
37
7
37
7
37
7
61
19

mm

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

6.6
3.3
7.9
3.3
9.1
4.2
11.0
5.3
12.9
5.3
14.5
6.6
16.2
6.6
18.0
7.9
20.6
9.1

2.2
1.0
2.2
1.0
2.2
1.0
2.2
1.0
2.4
1.0
2.4
1.2
2.4
1.2
2.4
1.2
2.4
1.4

mm

mm

Dia. of
wire for
armour
mm

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

mm

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight

mm

/km

-km

V/5min.

kg/km

1.0

26.8

0.3

2.0

33.0

1.6

29.8

0.4

2.1

36.6

1.8

1.2

32.8

0.4

2.2

39.8

1.9

1.2

36.7

0.4

2.4

44.1

2.1

1.4

42.0

0.4

2.6

49.8

2.3

1.4

45.5

0.4

2.7

53.5

2.4

1.6

49.3

0.4

2.9

57.7

2.6

1.6

53.4

0.4

3.0

62.0

2.8

1.6

59.0

0.4

3.3

68.2

3.0

830
790
730
790
640
640
550
530
510
530
460
510
420
510
380
440
340
440

6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500

2,070

1.2

0.734
3.110
0.529
3.110
0.391
1.840
0.270
1.160
0.195
1.160
0.154
0.734
0.126
0.734
0.100
0.529
0.0762
0.391

HV Power Cable

3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E

Max.
Dia.

2,630
3,270
4,300

LV Power & Lighting Cable

No.

Conductor
Nominal
Min.
Area
Number of
wires

5,490
6,690
7,800
9,420
11,900

Instrumentation &
Communication Cable

No. of
Cores

0.6/1kV(1.8/3kV) FX-BFOU(VFD)

mm2

25
6
35
6
50
10
70
16
95
16
120
25
150
25
185
35
240
50

Max.
overall
dia.

mm

mm

0.41
0.31
0.41
0.31
0.41
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41

7.8
3.9
9.2
3.9
11.0
5.1
13.1
6.3
15.1
6.3
17.0
7.8
19.0
7.8
21.0
9.2
24.0
11.0

Thickness Thickness Nominal


of
of
dia.
Insulation
inner
inner
covering covering
mm

2.2
1.0
2.2
1.0
2.2
1.0
2.2
1.0
2.4
1.0
2.4
1.2
2.4
1.2
2.4
1.2
2.4
1.4

mm

mm

Dia. of
wire for
armour
mm

Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm

mm

Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)

Test
Voltage

Cable
Weight

mm

/km

-km

V/5min.

kg/km

1.2

29.3

0.3

2.1

35.7

1.7

32.4

0.4

2.2

39.4

1.9

1.2

35.8

0.4

2.3

43.0

2.0

1.4

41.6

0.4

2.6

49.4

2.3

1.4

45.0

0.4

2.7

53.0

2.4

1.6

50.2

0.4

2.9

58.6

2.6

1.6

53.2

0.4

3.0

61.8

2.8

1.6

57.3

0.4

3.2

66.3

3.0

1.8

65.6

0.4

3.5

75.2

3.3

750
790
650
790
570
630
490
470
470
470
420
450
380
450
350
390
310
380

6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500

2,240

1.2

0.795
3.390
0.565
3.390
0.393
1.950
0.277
1.240
0.210
1.240
0.164
0.795
0.132
0.795
0.108
0.565
0.0817
0.393

Earthing & Bonding wire

3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E

Max.
dia. of
wires

2,840
3,640
4,870
5,770
7,210
8,300

VFD Cable

No.

Conductor
Nominal
Area

9,840
12,830

Technical Information

No. of
Cores

Offshore Cable

71

Technical Information

Electrical Data

73 ~ 81

Voltage Rating Selection

82

Test Methods & Equipment

83

Installation Recommendations

85 ~ 89

Core Identification

90

Handling, Installation Method & Notice

91

Certificates Approved

92

Class Type Approval

93

Technical Information

Technical Information

NEK-606 (2009), IEC 60092-350, 353, 354, 376

ELECTRICAL DATA

Conductor temperature

HV Power Cable

1. Current rating for continuous


90
Single core
(A)

Two core
(A)

Three core & four core


(A)

1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

18
23
30
40
52
72
96
127
157
196
242
293
339
389
444
522
601

15
20
26
34
44
61
82
108
133
167
206
249
288
331
377
444
511

13
16
21
28
36
50
67
89
110
137
169
205
237
273
311
366
420

Instrumentation &
Communication Cable

LV Power & Lighting Cable

Nominal cross-sectional area


(mm2)

NOTES)

Where, I1 : Current for single core cable



N : Number of cores

No. of cores

1.0SQMM

1.5SQMM

2.5SQMM

5
7
9
12
14
16
19
24
30
37
44

11
9
9
8
7
7
7
6
6
5
5

13
12
11
10
10
9
9
8
7
7
7

18
16
14
13
12
12
11
10
10
9
8

VFD Cable

I1
3

Maximum conductor
temperature

35

40

45

50

55

60

65

70

75

80

90

1.10

1.05

1.00

0.94

0.88

0.82

0.74

0.67

0.58

0.47

Technical Information

I=

Earthing & Bonding wire

1. Maximum permissible service temperature of the conductor is 90


2. The current ratings given above are based on an ambient air temperature of 45
3. The current ratings given above are for 6 cables of less bunched or laid together in flat formation.
When more than 6 cables are bunched or laid close together, the current ratings given above should
be multiplied correction factor 0.85.
In case of cables not being loaded simultaneously, consideration of the actual loading appertaining is permitted
4. For cables with more than 4 core cables, the current ratings are given by the Formula;

Correction factors for various ambient air temperature

Offshore Cable

73

Halogen free & Mud resistant Offshore cable

Technical Information
ELECTRICAL DATA
2. Capacitance, Inductance, Reactance, Impedance Data
3.6/6kV RFOU, 3.6/6kV RFCU, 3.6/6kV RFBU
Single core cable
Nominal Capacitance
Area
C
mm2

/km

10
16
25
35
50
70
95
120
150
185
240
300

0.247
0.284
0.328
0.362
0.408
0.466
0.528
0.581
0.624
0.695
0.742
0.770

Multi core cable

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

/km

/km

/km

0.144
0.136
0.128
0.123
0.118
0.112
0.108
0.104
0.102
0.099
0.097
0.096

0.173
0.164
0.154
0.148
0.142
0.135
0.129
0.125
0.123
0.119
0.117
0.115

2.351
1.485
0.945
0.686
0.512
0.362
0.273
0.224
0.193
0.165
0.140
0.126

2.353
1.488
0.949
0.691
0.518
0.370
0.282
0.234
0.205
0.177
0.154
0.141

0.247
0.284
0.328
0.362
0.408
0.466
0.528
0.581
0.624
0.695
0.742
-

0.458
0.434
0.409
0.393
0.375
0.358
0.343
0.332
0.326
0.317
0.310
0.305

Impedance Impedance Capacitance


Z
Z
C
at 50 Hz 90 at 60 Hz 90

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

/km

/km

0.102
0.096
0.091
0.088
0.085
0.082
0.079
0.077
0.076
0.074
0.073
-

0.122
0.115
0.109
0.106
0.102
0.098
0.095
0.093
0.091
0.089
0.088
-

2.348
1.482
0.940
0.680
0.506
0.354
0.263
0.213
0.181
0.151
0.125
-

2.349
1.484
0.942
0.683
0.509
0.358
0.268
0.219
0.187
0.159
0.134
-

0.324
0.306
0.290
0.281
0.270
0.260
0.252
0.246
0.242
0.237
0.234
-

Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90

6/10kV RFOU, 6/10kV RFCU, 6/10kV RFBU


Single core cable
Nominal Capacitance
Area
C
mm2

/km

16
25
35
50
70
95
120
150
185
240
300

0.228
0.261
0.287
0.321
0.365
0.411
0.450
0.484
0.535
0.591
0.651

Multi core cable


Impedance Impedance Capacitance
Z
C
Z
at 50 Hz 90 at 60 Hz 90

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

/km

/km

/km

0.141
0.134
0.128
0.123
0.116
0.111
0.109
0.106
0.104
0.101
0.098

0.170
0.160
0.153
0.147
0.140
0.134
0.130
0.127
0.124
0.121
0.117

1.486
0.945
0.687
0.513
0.363
0.275
0.226
0.195
0.167
0.143
0.128

1.489
0.950
0.692
0.520
0.371
0.284
0.237
0.207
0.181
0.158
0.143

0.228
0.261
0.287
0.321
0.365
0.411
0.450
0.484
0.535
0.591
-

0.450
0.425
0.407
0.390
0.370
0.355
0.346
0.337
0.330
0.321
0.311

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

/km

/km

0.105
0.099
0.096
0.092
0.088
0.085
0.083
0.081
0.079
0.077
-

0.126
0.119
0.115
0.110
0.106
0.102
0.099
0.097
0.095
0.092
-

1.483
0.941
0.681
0.507
0.355
0.265
0.215
0.183
0.153
0.127
-

1.484
0.943
0.684
0.511
0.360
0.271
0.222
0.190
0.162
0.137
-

0.335
0.316
0.305
0.292
0.280
0.270
0.263
0.258
0.251
0.245
-

Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90

8.7/15kV RFOU, 8.7/15kV RFCU, 8.7/15kV RFBU


Single core cable
Nominal Capacitance
Area
C
mm2

/km

25
35
50
70
95
120
150
185
240
300

0.215
0.235
0.261
0.295
0.330
0.360
0.386
0.424
0.468
0.514

74

Offshore Cable

Multi core cable

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

/km

/km

/km

0.139
0.133
0.128
0.121
0.117
0.114
0.111
0.107
0.104
0.102

0.167
0.160
0.153
0.145
0.140
0.137
0.133
0.129
0.125
0.122

0.946
0.688
0.515
0.365
0.277
0.229
0.198
0.169
0.145
0.131

0.951
0.693
0.522
0.374
0.288
0.241
0.211
0.184
0.161
0.147

0.215
0.235
0.261
0.295
0.330
0.360
0.386
0.424
0.468
-

0.443
0.424
0.406
0.386
0.371
0.362
0.353
0.341
0.332
0.324

Impedance Impedance Capacitance


Z
Z
C
at 50 Hz 90 at 60 Hz 90

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

/km

/km

0.108
0.104
0.099
0.095
0.091
0.088
0.086
0.084
0.082
-

0.130
0.125
0.119
0.114
0.109
0.106
0.104
0.101
0.098
-

0.942
0.682
0.508
0.357
0.267
0.217
0.185
0.156
0.130
-

0.945
0.686
0.513
0.363
0.274
0.225
0.194
0.166
0.141
-

0.344
0.330
0.316
0.302
0.290
0.281
0.275
0.267
0.260
-

Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90

Technical Information

NEK-606 (2009), IEC 60092-350, 353, 354, 376

0.6/1kV(1.8/3kV) RFOU(VFD)
Capacitance
C

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

Impedance
Z
at 50 Hz 90

Impedance
Z
at 60 Hz 90

No.

mm2

/km

mH / km

/km

/km

/km

/km

3C
3E
3C
3E
3C
3E
3C
3E
3C
3E

95
16
120
25
150
25
185
35
240
50

0.582

0.255

0.080

0.096

0.264

0.269

0.667

0.249

0.078

0.094

0.213

0.219

0.715

0.244

0.077

0.092

0.181

0.188

0.736

0.238

0.075

0.090

0.151

0.159

0.794

0.233

0.073

0.088

0.125

0.134

LV Power & Lighting Cable

Nominal
Area

HV Power Cable

Multi core cable


No. of
Cores

0.6/1kV(1.8/3kV) BFOU(VFD)
Capacitance
C

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

Impedance
Z
at 50 Hz 90

Impedance
Z
at 60 Hz 90

No.

mm2

/km

mH / km

/km

/km

/km

/km

3C
3E
3C
3E
3C
3E
3C
3E
3C
3E

95
16
120
25
150
25
185
35
240
50

0.550

0.262

0.082

0.099

0.264

0.270

0.603

0.255

0.080

0.096

0.214

0.220

0.658

0.250

0.079

0.094

0.182

0.189

0.715

0.244

0.077

0.092

0.152

0.160

0.770

0.238

0.075

0.090

0.126

0.135

Earthing & Bonding wire

Nominal
Area

Instrumentation &
Communication Cable

Multi core cable


No. of
Cores

0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU

/km

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

0.199
0.237
0.282
0.326
0.401
0.490
0.509
0.588
0.591
0.705
0.713
0.813
0.793
0.799
0.832
0.857

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

0.171
0.159
0.148
0.138
0.128
0.119
0.113
0.107
0.104
0.099
0.096
0.093
0.092
0.091
0.089
0.090

0.206
0.191
0.177
0.166
0.154
0.143
0.136
0.129
0.125
0.119
0.116
0.111
0.110
0.109
0.106
0.108

0.546
0.506
0.471
0.441
0.409
0.379
0.360
0.342
0.332
0.315
0.307
0.296
0.293
0.289
0.282
0.286

Multi core cable


Impedance Impedance Capacitance
Z
Z
C
at 50 Hz 90 at 60 Hz 90

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90

/km

/km

/km

mH / km

/km

/km

/km

/km

15.557
9.641
5.995
3.968
2.350
1.484
0.943
0.683
0.509
0.358
0.269
0.219
0.188
0.160
0.134
0.122

15.558
9.642
5.996
3.969
2.351
1.486
0.946
0.687
0.514
0.364
0.276
0.228
0.197
0.171
0.147
0.136

0.305
0.345
0.379
0.435
0.477
0.500
0.589
0.685
0.705
0.715
0.770
0.834
0.834
0.834
0.848
0.848

0.356
0.329
0.307
0.291
0.272
0.257
0.254
0.245
0.245
0.236
0.235
0.230
0.231
0.232
0.230
0.230

0.112
0.103
0.096
0.091
0.085
0.081
0.080
0.077
0.077
0.074
0.074
0.072
0.072
0.073
0.072
0.072

0.134
0.124
0.116
0.110
0.102
0.097
0.096
0.092
0.092
0.089
0.089
0.087
0.087
0.088
0.087
0.087

15.557
9.640
5.994
3.967
2.348
1.481
0.939
0.679
0.504
0.352
0.262
0.211
0.179
0.150
0.124
0.109

15.557
9641
5.994
3.967
2.348
1.482
0.941
0.681
0.507
0.356
0.266
0.216
0.185
0.158
0.133
0.119

VFD Cable

mm2

Inductance
L

Technical Information

Single core cable * )


Nominal Capacitance
Area
C

* Reactance for 1-conductor cables given at Three-foil formation

Offshore Cable

75

Halogen free & Mud resistant Offshore cable

Technical Information
0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU
Single core cable * )
Nominal Capacitance
Area
C
mm2

/km

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

0.172
0.203
0.239
0.276
0.336
0.436
0.461
0.531
0.542
0.644
0.660
0.749
0.738
0.749
0.784
0.811

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

0.175
0.162
0.151
0.142
0.131
0.121
0.115
0.109
0.106
0.101
0.098
0.094
0.093
0.092
0.089
0.090

0.210
0.195
0.181
0.171
0.157
0.146
0.138
0.131
0.127
0.121
0.117
0.113
0.112
0.110
0.107
0.108

0.556
0.516
0.480
0.453
0.417
0.387
0.367
0.348
0.337
0.320
0.311
0.301
0.296
0.291
0.284
0.288

Multi core cable


Impedance Impedance Capacitance
Z
Z
C
at 50 Hz 90 at 60 Hz 90
/km

/km

15.557
9.641
5.995
3.968
2.350
1.484
0.943
0.683
0.510
0.359
0.269
0.220
0.188
0.160
0.135
0.122

15.558
9.642
5.996
3.969
2.351
1.486
0.946
0.687
0.515
0.365
0.277
0.228
0.198
0.171
0.147
0.136

/km

0.278
0.309
0.345
0.385
0.435
0.500
0.527
0.556
0.589
0.695
0.715
0.758
0.758
0.782
0.807
0.820

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

0.382
0.353
0.328
0.309
0.288
0.271
0.265
0.255
0.253
0.243
0.242
0.237
0.236
0.235
0.233
0.232

0.120
0.111
0.103
0.097
0.090
0.085
0.083
0.080
0.080
0.076
0.076
0.074
0.074
0.074
0.073
0.073

0.144
0.133
0.124
0.117
0.108
0.102
0.100
0.096
0.096
0.092
0.091
0.089
0.089
0.089
0.088
0.087

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

0.112
0.103
0.096
0.091
0.085
0.081
0.080
0.077
0.077
0.074
0.074
0.072
0.072
0.073
0.072
0.072

0.134
0.124
0.116
0.110
0.102
0.097
0.096
0.092
0.092
0.089
0.089
0.087
0.087
0.088
0.087
0.087

Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90
/km

/km

15.557
9.640
5.994
3.967
2.348
1.482
0.940
0.679
0.505
0.353
0.262
0.212
0.180
0.151
0.125
0.110

15.557
9641
5.994
3.967
2.349
1.483
0.941
0.681
0.508
0.356
0.267
0.217
0.186
0.158
0.134
0.120

* Reactance for 1-conductor cables given at Three-foil formation

0.6/1kV RU
Single core cable * )
Nominal Capacitance
Area
C
mm2

/km

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

0.199
0.237
0.282
0.326
0.401
0.490
0.509
0.588
0.591
0.705
0.713
0.813
0.793
0.799
0.832
0.857

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

0.142
0.131
0.121
0.114
0.105
0.099
0.095
0.092
0.091
0.086
0.085
0.083
0.083
0.083
0.081
0.081

0.170
0.157
0.146
0.137
0.126
0.119
0.114
0.110
0.109
0.103
0.102
0.100
0.099
0.099
0.098
0.097

0.451
0.417
0.387
0.363
0.334
0.316
0.303
0.292
0.288
0.274
0.271
0.264
0.264
0.263
0.259
0.258

* Reactance for 1-conductor cables given at Three-foil formation

76

Offshore Cable

Multi core cable


Impedance Impedance Capacitance
Z
Z
C
at 50 Hz 90 at 60 Hz 90
/km

/km

15.557
9.641
5.994
3.967
2.349
1.482
0.941
0.681
0.507
0.355
0.265
0.215
0.183
0.155
0.130
0.115

15.557
9.641
5.995
3.968
2.350
1.484
0.943
0.683
0.510
0.359
0.271
0.222
0.192
0.165
0.141
0.127

/km

0.305
0.345
0.379
0.435
0.477
0.500
0.589
0.685
0.705
0.715
0.770
0.834
0.834
0.834
0.848
0.848

0.356
0.329
0.307
0.291
0.272
0.257
0.254
0.245
0.245
0.236
0.235
0.230
0.231
0.232
0.230
0.230

Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90
/km

/km

15.557
9.640
5.994
3.967
2.348
1.481
0.939
0.679
0.504
0.352
0.262
0.211
0.179
0.150
0.124
0.109

15.557
9.641
5.994
3.967
2.348
1.482
0.941
0.681
0.507
0.356
0.266
0.216
0.185
0.158
0.133
0.119

Technical Information

NEK-606 (2009), IEC 60092-350, 353, 354, 376

0.6/1kV BU

/km

Reactance
X
50 Hz

Reactance
X
60 Hz

mH / km

/km

/km

Impedance Impedance Capacitance


Z
Z
C
at 50 Hz 90 at 60 Hz 90
/km

1.5
0.172
0.468
0.147
0.176
15.557
2.5
0.203
0.432
0.136
0.163
9.641
4
0.239
0.401
0.126
0.151
5.994
6
0.276
0.376
0.118
0.142
3.967
10
0.336
0.351
0.110
0.132
2.349
16
0.436
0.326
0.102
0.123
1.483
25
0.461
0.315
0.099
0.119
0.941
35
0.531
0.300
0.094
0.113
0.681
50
0.542
0.295
0.093
0.111
0.507
70
0.644
0.283
0.089
0.107
0.356
95
0.660
0.276
0.087
0.104
0.266
120
0.749
0.270
0.085
0.102
0.216
150
0.738
0.268
0.084
0.101
0.184
185
0.749
0.266
0.083
0.100
0.156
240
0.784
0.261
0.082
0.098
0.130
CABLE
TYPE
:
0.6/1kV(1.8/3kV)
BFOU(VFD)
300
0.811
0.260
0.082
0.098
0.116

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90

/km

/km

mH / km

/km

/km

/km

/km

15.557
9.641
5.995
3.968
2.350
1.484
0.943
0.684
0.511
0.360
0.272
0.223
0.192
0.165
0.141
0.128

0.278
0.309
0.345
0.385
0.435
0.500
0.527
0.556
0.589
0.695
0.715
0.758
0.758
0.782
0.807
0.820

0.382
0.353
0.328
0.309
0.288
0.271
0.265
0.255
0.253
0.243
0.242
0.237
0.236
0.235
0.233
0.232

0.120
0.111
0.103
0.097
0.090
0.085
0.083
0.080
0.080
0.076
0.076
0.074
0.074
0.074
0.073
0.073

0.144
0.133
0.124
0.117
0.108
0.102
0.100
0.096
0.096
0.092
0.091
0.089
0.089
0.089
0.088
0.087

15.557
9.640
5.994
3.967
2.348
1.482
0.940
0.679
0.505
0.353
0.262
0.212
0.180
0.151
0.125
0.110

15.557
9.641
5.994
3.967
2.349
1.483
0.941
0.681
0.508
0.356
0.267
0.217
0.186
0.158
0.134
0.120

HV Power Cable

mm2

Multi core cable

Inductance
L

LV Power & Lighting Cable

Single core cable * )


Nominal Capacitance
Area
C

Instrumentation &
Communication Cable

* Reactance for 1-conductor cables given at Three-foil formation

Size

1.0mm2

1.5mm2

2.5mm2

Individual screen

nF/km

100

100

120

120

Collective screen

nF/km

80

80

90

90

mH/km

0.75

0.73

0.68

0.68

Inductance

VFD Cable

0.75mm2

Technical Information

Mutual
capacitance

unit

Earthing & Bonding wire

250V Instrument & communication cables.

Offshore Cable

77

Halogen free & Mud resistant Offshore cable

Technical Information
ELECTRICAL DATA
3. Short circuit current rating
The short circuit currents quoted here are for cables operating normally at maximum conductor temperature of 90.
HF EPR insulation is actually capable of withstanding short-term Temperature up to 250
According to ICEA P-32-382 Curves based on formula

Is = A x

Where  Is : Short Circuit Current (kA)



A : Conductor area ()

T1 : Operating temperature ( 90)

T2 : Short Circuit temperature ( 250)

t : Short Circuit duration (sec)

(T2 + 234)
(T1 + 234)

0.115 log
t

T1 = 90, T2 = 250
Short circuit currents (kA)

Nominal
Area
mm2

78

Duration of short circuit in second


0.03

0.05

0.07

0.1

0.14

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.5

1.3

1.0

0.8

0.7

0.6

0.5

0.4

0.3

0.3

0.3

0.3

0.2

0.2

0.2

2.5

2.0

1.6

1.3

1.1

0.9

0.8

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

3.2

2.5

2.1

1.8

1.5

1.3

1.0

0.9

0.8

0.7

0.7

0.6

0.6

0.6

4.9

3.8

3.2

2.7

2.3

1.9

1.5

1.3

1.2

1.1

1.0

0.9

0.9

0.8

10

8.2

6.3

5.4

4.5

3.8

3.2

2.6

2.2

2.0

1.8

1.7

1.6

1.5

1.4

16

13.0

10.1

8.5

7.1

6.0

5.0

4.1

3.6

3.2

2.9

2.7

2.5

2.4

2.2

25

20.6

15.9

13.5

11.3

9.5

8.0

6.5

5.6

5.0

4.6

4.3

4.0

3.8

3.6

35

28.5

22.1

18.7

15.6

13.2

11.1

9.0

7.8

7.0

6.4

5.9

5.5

5.2

4.9

50

38.6

29.9

25.3

21.2

17.9

15.0

12.2

10.6

9.5

8.6

8.0

7.5

7.1

6.7

70

55.9

43.3

36.6

30.6

25.9

21.6

17.7

15.3

13.7

12.5

11.6

10.8

10.2

9.7

95

77.5

60.0

50.7

42.4

35.9

30.0

24.5

21.2

19.0

17.3

16.0

15.0

14.1

13.4

120

97.9

75.8

64.1

53.6

45.3

37.9

31.0

26.8

24.0

21.9

20.3

19.0

17.9

17.0

150

120.3

93.1

78.7

65.9

55.7

46.6

38.0

32.9

29.5

26.9

24.9

23.3

22.0

20.8

185

150.8

116.8

98.8

82.6

69.8

58.4

47.7

41.3

36.9

33.7

31.2

29.2

27.5

26.1

240

198.3

153.6

129.8

108.6

91.8

76.8

62.7

54.3

48.6

44.3

41.0

38.4

36.2

34.3

300

248.7

192.6

162.8

136.2

115.1

96.3

78.6

68.1

60.9

55.6

51.5

48.2

45.4

43.1

400

329.3

255.1

215.6

180.4

152.5

127.6

104.1

90.2

80.7

73.6

68.2

63.8

60.1

57.0

500

401.0

310.6

262.5

219.6

185.6

155.3

126.8

109.8

98.2

89.7

83.0

77.7

73.2

69.5

Offshore Cable

Technical Information

NEK-606 (2009), IEC 60092-350, 353, 354, 376

4. Voltage drop

Rdc x 2L x I
V

Voltage drop rate =

2) A.C. circuit
Voltage drop rate of single-phase A.C.=
Voltage drop rate of three-phase A.C.=

x 100(%)
Rac x 2L x I
V
Rac x 2L x I
V

x x 100(%)
3

x 2

x x 100(%)

Where L

I

V

Rdc



Rac



: Cable length (km)


: Current(A)
: Circuit Voltage(V)
: D.C. resistance at maximum rated
conductor temperature
(see following table)
: A.C. resistance at maximum rated
conductor temperature
(see following table)
: Inductive voltage drop coefficient

Voltage drop coefficient


3.6/6kV RFOU. 3.6/6kV RFCU, 3.6/6kV RFBU
Inductive voltage drop coefficient

Nominal
Area

R-dc
(at 20)

R-dc
(at 90)

R-ac
(at 90)

mm2

/km

/km

/km

100%

95%

90%

85%

80%

75%

70%

10
16
25
35
50
70
95
120
150
185
240

1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762

2.346
1.479
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972

2.346
1.479
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.97
0.98
1.00
1.02
1.04
1.07
1.11
1.15
1.18
1.23
1.31

0.93
0.95
0.97
1.00
1.02
1.07
1.12
1.17
1.23
1.30
1.40

0.89
0.91
0.94
0.97
1.00
1.06
1.12
1.18
1.25
1.33
1.46

0.84
0.87
0.90
0.93
0.97
1.04
1.11
1.18
1.25
1.35
1.49

0.80
0.82
0.86
0.90
0.94
1.01
1.09
1.17
1.25
1.35
1.51

0.75
0.78
0.82
0.86
0.90
0.98
1.07
1.15
1.24
1.35
1.53

Instrumentation &
Communication Cable

Dielectric power factor (at 60HZ & 90 Conductor temperature)

R-dc
(at 90)

R-ac
(at 90)

mm2

/km

/km

/km

16
25
35
50
70
95
120
150
185
240

1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762

1.479
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972

1.479
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010

Inductive voltage drop coefficient


Dielectric power factor (at 60HZ & 90 Conductor temperature)
100%

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

95%

0.99
1.00
1.02
1.04
1.08
1.12
1.16
1.19
1.25
1.32

90%

0.95
0.97
1.00
1.03
1.08
1.13
1.19
1.24
1.31
1.42

85%

0.91
0.94
0.97
1.01
1.06
1.13
1.20
1.26
1.35
1.48

80%

0.87
0.90
0.94
0.98
1.04
1.12
1.19
1.27
1.37
1.52

75%

0.83
0.86
0.90
0.95
1.02
1.10
1.19
1.26
1.38
1.54

70%

0.78
0.82
0.86
0.91
0.99
1.08
1.17
1.25
1.38
1.55

VFD Cable

R-dc
(at 20)

Earthing & Bonding wire

6/10kV RFOU, 6/10kV RFCU, 6/10kV RFBU


Nominal
Area

LV Power & Lighting Cable

1) D.C. circuit

HV Power Cable

Calculate fomula

8.7/15kV RFOU, 8.7/15kV RFCU, 8.7/15kV RFBU


Inductive voltage drop coefficient

Nominal
Area

R-dc
(at 20)

R-dc
(at 90)

R-ac
(at 90)

mm2

/km

/km

/km

100%

95%

90%

85%

80%

75%

70%

25
35
50
70
95
120
150
185
240

0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762

0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972

0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

1.01
1.02
1.05
1.08
1.12
1.17
1.20
1.26
1.34

0.98
1.00
1.03
1.08
1.14
1.20
1.25
1.33
1.44

0.94
0.97
1.01
1.07
1.14
1.21
1.28
1.37
1.50

0.91
0.94
0.98
1.05
1.13
1.21
1.29
1.39
1.54

0.87
0.91
0.95
1.03
1.12
1.21
1.29
1.40
1.57

0.83
0.87
0.92
1.00
1.10
1.19
1.28
1.40
1.58

Offshore Cable

Technical Information

Dielectric power factor (at 60HZ & 90 Conductor temperature)

79

Halogen free & Mud resistant Offshore cable

Technical Information
ELECTRICAL DATA
0.6/1Kv(1.8/3kV) RFOU(VFD)
Nominal
Area

R-dc
(at 20)

R-dc
(at 90)

R-ac
(at 90)

mm2
95
16
120
25
150
25
185
35
240
50

ohm/km
0.195
1.160
0.154
0.734
0.126
0.734
0.100
0.529
0.076
0.391

ohm/km
0.249
1.479
0.196
0.936
0.161
0.936
0.128
0.675
0.097
0.499

ohm/km
0.251
1.479
0.198
0.936
0.164
0.936
0.131
0.675
0.101
0.499

Inductive voltage drop coefficient


Dielectric power factor (at 60Hz & 90 Conductor temperature)
100%
1.00

95%
1.07

90%
1.07

85%
1.05

80%
1.03

75%
1.00

70%
0.97

1.00

1.10

1.11

1.10

1.08

1.06

1.04

1.00

1.13

1.15

1.15

1.14

1.12

1.10

1.00

1.16

1.20

1.21

1.21

1.20

1.19

1.00

1.22

1.28

1.31

1.32

1.33

1.32

0.6/1kV (1.8/3kV) BFOU(VFD)


Inductive voltage drop coefficient

Nominal
Area

R-dc
(at 20)

R-dc
(at 90)

R-ac
(at 90)

mm2

ohm/km

ohm/km

ohm/km

100%

95%

90%

85%

80%

75%

70%

95
16
120
25
150
25
185
35
240
50

0.195
1.160
0.154
0.734
0.126
0.734
0.100
0.529
0.076
0.391

0.249
1.479
0.196
0.936
0.161
0.936
0.128
0.675
0.097
0.499

0.251
1.479
0.198
0.936
0.164
0.936
0.131
0.675
0.101
0.499

1.00

1.07

1.07

1.06

1.04

1.01

0.98

1.00

1.10

1.11

1.11

1.09

1.07

1.05

1.00

1.13

1.15

1.15

1.15

1.13

1.11

1.00

1.17

1.21

1.22

1.22

1.21

1.20

1.00

1.23

1.29

1.32

1.33

1.34

1.33

Dielectric power factor (at 60Hz & 90 Conductor temperature)

0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU


Inductive voltage drop coefficient

Nominal
Area

R-dc
(at 20)

R-dc
(at 90)

R-ac
(at 90)

mm2

ohm/km

ohm/km

ohm/km

100%

95%

90%

85%

80%

75%

70%

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

12.2
7.56
4.70
3.11
1.84
1.16
0734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607

15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774

15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010
0.0820

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.95
0.96
0.96
0.96
0.97
0.98
1.00
1.01
1.03
1.06
1.09
1.13
1.16
1.21
1.28
1.36

0.91
0.91
0.91
0.92
0.93
0.94
0.96
0.98
1.01
1.05
1.10
1.15
1.19
1.26
1.36
1.47

0.86
0.86
0.87
0.87
0.88
0.90
0.93
0.95
0.98
1.03
1.09
1.15
1.20
1.29
1.41
1.54

0.81
0.81
0.82
0.83
0.84
0.86
0.89
0.91
0.95
1.01
1.08
1.14
1.20
1.30
1.43
1.59

0.76
0.76
0.77
0.78
0.79
0.81
0.85
0.88
0.92
0.98
1.05
1.12
1.20
1.30
1.45
1.62

0.71
0.71
0.72
0.73
0.75
0.77
0.80
0.84
0.88
0.95
1.03
1.10
1.18
1.29
1.45
1.64

80

Offshore Cable

Dielectric power factor (at 60Hz & 90 Conductor temperature)

Technical Information

NEK-606 (2009), IEC 60092-350, 353, 354, 376

0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU


Inductive voltage drop coefficient

Nominal
Area

R-dc
(at 20)

R-dc
(at 90)

R-ac
(at 90)

mm2

ohm/km

ohm/km

ohm/km

100%

95%

90%

85%

80%

75%

70%

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607

15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774

15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010
0.0820

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.95
0.96
0.96
0.96
0.97
0.98
1.00
1.01
1.03
1.06
1.10
1.13
1.16
1.21
1.28
1.36

0.91
0.91
0.91
0.92
0.93
0.94
0.96
0.98
1.01
1.05
1.10
1.15
1.20
1.26
1.36
1.48

0.86
0.86
0.87
0.87
0.89
0.90
0.93
0.95
0.98
1.03
1.10
1.15
1.21
1.29
1.41
1.55

0.81
0.81
0.82
0.83
0.84
0.86
0.89
0.92
0.95
1.01
1.08
1.14
1.21
1.30
1.44
1.59

0.76
0.76
0.77
0.78
0.79
0.82
0.85
0.88
0.92
0.98
1.06
1.13
1.20
1.30
1.45
1.62

0.71
0.71
0.72
0.73
0.75
0.77
0.81
0.84
0.88
0.95
1.03
1.11
1.19
1.30
1.46
1.64

LV Power & Lighting Cable

HV Power Cable

Dielectric power factor (at 60Hz & 90 Conductor temperature)

0.6/1kV RU
R-dc
(at 20)

R-dc
(at 90)

R-ac
(at 90)

mm2

ohm/km

ohm/km

ohm/km

100%

95%

90%

85%

80%

75%

70%

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

12.2
7.56
4.70
3.11
1.84
1.16
0734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607

15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774

15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010
0.0820

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.95
0.96
0.96
0.96
0.97
0.98
0.99
1.00
1.02
1.04
1.08
1.11
1.14
1.19
1.25
1.32

0.90
0.91
0.91
0.92
0.92
0.94
0.95
0.97
1.00
1.03
1.08
1.12
1.16
1.23
1.32
1.42

0.86
0.86
0.86
0.87
0.88
0.89
0.91
0.94
0.96
1.01
1.06
1.11
1.17
1.25
1.36
1.48

0.81
0.81
0.81
0.82
0.83
0.85
0.87
0.90
0.93
0.98
1.04
1.10
1.16
1.25
1.38
1.51

0.76
0.76
0.77
0.77
0.79
0.80
0.83
0.86
0.89
0.95
1.02
1.08
1.15
1.25
1.39
1.54

0.71
0.71
0.72
0.72
0.74
0.76
0.79
0.82
0.86
0.91
0.99
1.06
1.13
1.24
1.39
1.55

Instrumentation &
Communication Cable

Inductive voltage drop coefficient

Nominal
Area

Earthing & Bonding wire

Dielectric power factor (at 60Hz & 90 Conductor temperature)

0.6/1kV BU
Inductive voltage drop coefficient

Nominal
Area

R-dc
(at 20)

R-dc
(at 90)

R-ac
(at 90)

mm2

ohm/km

ohm/km

ohm/km

100%

95%

90%

85%

80%

75%

70%

1.5
2.5
4
6
10
16
25
35
50
70
95
120
50
185
240
300

12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607

15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0344
0.249
0.196
0.161
0.128
0.0972
0.0774

15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010
0.0820

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.95
0.96
0.96
0.96
0.97
0.98
0.99
1.00
1.02
1.05
1.08
1.11
1.14
1.19
1.25
1.32

0.90
0.91
0.91
0.92
0.92
0.94
0.96
0.97
1.00
1.03
1.08
1.12
1.17
1.23
1.32
1.42

0.86
0.86
0.86
0.87
0.88
0.89
0.92
0.94
0.97
1.01
1.07
1.12
1.18
1.25
1.36
1.48

0.81
0.81
0.82
0.82
0.83
0.85
0.88
0.90
0.93
0.99
1.05
1.11
1.17
1.26
1.38
1.52

0.76
0.76
0.77
0.77
0.79
0.80
0.83
0.86
0.90
0.95
1.02
1.09
1.16
1.25
1.39
1.54

0.71
0.71
0.72
0.73
0.74
0.76
0.79
0.82
0.86
0.92
1.00
1.07
1.14
1.24
1.40
1.55

Offshore Cable

Technical Information

VFD Cable

Dielectric power factor (at 60Hz & 90 Conductor temperature)

81

Halogen free & Mud resistant Offshore cable

Technical Information
VOLTAGE RATING SELECTION
Selection cable for A.C systems
System voltage (kV)
Supply
system

3-Phase 4-Wire
3-Phase 4-Wire

3-Phase 3-Wire

3-Phase 3-Wire

2-Phase 3-Wire
or 2-Phase 4-Wire

Supply
category

A&B
C

A&B

A&B

2-Phase 3-Wire
or 2-Phase 4-Wire

1-Phase 3-Wire

A&B

1-Phase 3-Wire

1-Phase 2-Wire
or
1-Phase 1-Wire

Note)

Phase to earth
(Uo)

Recommended (kV)

Phase to phase
(U)

Above

Up to and
including

Above

Up to and
including

Maximum
sustained
voltage
(Um)

IEC
standard

BS
standards

UO / U

UO / U

0.15 / 0.25

0.15

0.25

0.28

0.15 / 0.25

0.15

0.6

0.25

1.2

0.6 / 1

0.6 / 1

0.15

0.15 / 0.25

0.15 / 0.25

0.15

0.6

0.6 / 1

0.6 / 1

0.15

0.25

0.28

0.15 / 0.25

0.15 / 0.25

0.15

0.6

0.25

1.2

0.6 / 1

0.6 / 1

0.6

1.9

3.3

3.6

1.8 / 3

1.9 / 3.3

1.9

3.8

3.3

6.6

7.2

3.6 / 6

3.8 / 6.6

3.8

6.35

6.6

11

12

6 / 10

6.35 / 11

6.35

8.7

11

15

17

8.7 / 15

8.7

12.7

15

22

24

12 / 20

12.7 / 22
0.15 / 0.25

0.15

0.15 / 0.25

0.15

0.6

0.6 / 1

0.6 / 1

0.6

1.9

1.8 / 3

1.9 / 3.3

1.9

3.3

3.6

3.6 / 6

3.8 / 6.6

3.3

6.6

7.2

6 / 10

6.35 / 11

6.6

11

12

8.7 / 15

11 / 11

11

15

17.5

12 / 20

12.7 / 22

0.15

0.21

0.15 / 0.25

0.15 / 0.25

0.15

0.6

0.84

0.6 / 1

0.6 / 1

0.15

0.15 / 0.25

0.15 / 0.25

0.15

0.a6

0.6 / 1

0.6 / 1

0.6

1.9

1.8 / 3

1.9 / 3.3

0.15

0.25

0.28

0.15 / 0.25

0.15 / 0.25

0.15

0.6

0.25

1.2

0.6 / 1

0.6 / 1
0.15 / 0.25

0.15

0.15 /0.25

0.25

0.6

0.6 / 1

0.6 / 1

0.15

0.15 /0.25

0.15 / 0.25

0.15

0.6

0.6 / 1

0.6 / 1

0.6

1.9

1.8 / 3

19. / 3.3

1.9

3.3

3.6

3.6 / 6

3.8 / 6.6

3.3

6.6

7.2

6 / 10

6.35 / 11

6.6

11

12

8.7 / 15

11

15

17.5

12 / 20

12.7 / 22

The rated voltage of the cable for a given application shall be suitable for the operating condition in the system in which the cable is used. To facilitate the
choice of the cable, the system are divided into the following three categories
Category A : This category comprises those systems in which any phase conductor than comes in contact with earth or an earth conductor , is
automatically disconnected from the system within 1 minute.
Category B : This category comprises those systems in which, under fault conditions, are operated for a short time, not exceeding 8 hours on any
occasion, faults in any year should not exceed 125 hours.
Category C : This category comprises all systems which do not fall into categories A and B.

82

Offshore Cable

Technical Information

NEK-606 (2009), IEC 60092-350, 353, 354, 376

3. Cold test (Bending / Impact)

4. Halogen content test

CSA C22.2 No.03 (-40/ -35)

IEC 60754-1,2 Test

5. Smoke emission test

6. Oxygen index test

IEC 61034-1,2 Test

ASTM D 2863

LV Power & Lighting Cable

IEC 60331 (at 750, 1000)

Instrumentation &
Communication Cable

IEC 60332-3. CAT. A (VTFT)

Earthing & Bonding wire

2. Fire resistant test

Technical Information

VFD Cable

1. Flame retardant test

HV Power Cable

TEST METHODS & TEST EQUIPMENT

Offshore Cable

83

Halogen free & Mud resistant Offshore cable

Technical Information
7. Mud resistant test
 ud resistant cables shall be designed with sheathing compounds suitable for installation and operation in contact with MUD
M
unless otherwise specified. Type SHF Mud.
The variation in the tensile strength and elongation at break values from those values obtained on the
unaged sample shell not exceed 25%.
The volume swell and weight increase shell not exceed 20%and 15% respectively.

1) IRM 903 requirements


The variation in the tensile strength and elongation at break values from those values
obtained on the unaged sample shell not exceed 30%.

2) Drilling fluid mud test requirements for sheathing compound SHF mud
Test shall be carried out on dumbbells as specified in IEC 60092-359 Table clause 3 except that the test fluids and
conditions shall be as given in Table 1.
Tesa fluid

Mineral oil type-IRM 903

Temperature

Duration

100

7d

Calcium Bromide Brine (Water based)

70

56d

Carbo Sea (oil based)

70

56d

8. Oil resistance
All thermoset sheathed cables shall be suitable for an oil production installation. The oil resistance properties shall be
demonstrated by a test according to IEC 60092-359 Table clause 3, type SHF2.

84

Offshore Cable

Technical Information

NEK-606 (2009), IEC 60092-350, 353, 354, 376

INSTALLATION RECOMMENDATIONS
HV Power Cable

The following installation recommendations are in accordance with IEC regulation and practice.
Different regulations may apply in other countries.

1. Minimum cable bending radius

Type of cable

LV Power & Lighting Cable

The bending radius for the installation of cables should be not less than the values given as follows;
Minimum bending radius

Unarmored or unbraided

1.8/3kV

3.6/6kV
above

D 25mm

4XD

D 25mm

6XD

Metal braid screened or armored

6XD

Tape screened

8XD

Single core

12 X D

3-core

9XD

r
Instrumentation &
Communication Cable

Up to

Note) For cables rated at 3.6/6(7.2)kV and above employing flexible conductor
stranding(Class5) and braid insulation shields indicating a minimum bend radius of 6D
for unarmoured cables and 8D for armoured cables in concurrence with the approval
of the cable manufacturer.

Earthing & Bonding wire

Notes) D : Overall diameter of cable

2. Installation temperature
Minimum recommended installation temperature for cables shall be -20.
But, if the ambient temperature were below -20, the cable should be installed after maintained at room temperature
(about 15~25) for 24 hours or more.

VFD Cable

3. Pulling tension
The cable pulling tension during installation can be estimated by means of the following formula:
p=5kg x total cross section of conductors in the armoured cable or,
p=2.5kg x total cross section of conductors in the unarmoured cable

Technical Information

Additional tension will be supplied from the braid and the insulation and sheathing compound.

Offshore Cable

85

Halogen free & Mud resistant Offshore cable

Technical Information
4. Explosion risk areas
1) Areas
The areas on board are usually classified in two main categories with regards to the explosion risk :
Hazardous areas : Areas in which explosive gas-air mixtures are, or may be expected to be,present in
quantities such as to require special precautions for the construction and use of electrical apparatus.
Safe areas(non-hazardous areas ) : Area in which explosive gas-air mixtures are not expected to be, present in
quantities such as to required special precautions for the construction and use of electrical apparatus.
A hazardous area is divided into three zones :
Zone 0 : in which an explosive gas-air mixture is continuously present or present for long periods.
Zone 1 : in which an explosive gas-air mixture is likely to occur in normal operation
Zone 2 : in which an explosive gas-air mixture is not likely to occur, and if occurs it will only exist for a short time

2) Installation of cables
For cables to be used in zone 0 and zone 1, one of the following types of protection is required:
A non-metallic outer sheath in combination with braiding or other metallic covering for earth fault

detection and mechanical protection. A non-metallic outer sheath is, however, not required if the
screen or armouring consists of a corrosion resistant bronze alloy.
A
 lead sheathing in addition to further mechanical protection, for example armour braiding or
non-metallic impervious sheath.
For mineral insulated cables, a copper or stainless steel sheath.
Single core cables in installations with A.C or D.C. current with a high ripple content should be of types
without screen of armouring. where mechanical damage is possible, such cables should otherwise be
mechanically protected or installed in ducts or similar.
For installations in zone 2, cables without screen or armour can be used.

86

Offshore Cable

Technical Information

NEK-606 (2009), IEC 60092-350, 353, 354, 376

5. Earthing of metal coverings of cables


HV Power Cable

1) General requirements
All metal coverings of cables, armouring or shielding shall be earthed. Earthing must be provided at both ends except
for final sub-circuits where earthing at only one end(the supply end)is sufficient.
Earthing at one end is permitted where it is required for technical or safety reasons, control and instrumentation cables,
mineral insulated cables, intrinsically safe circuits, control circuits etc.

LV Power & Lighting Cable

Metal covering of single core cable for AC and single core cable for DC with ripple content exceeding 10% and having
a current rating exceeding 20A is to be earthed at one and only.
when single core cables for AC and DC with ripple content higher than 10% are installed in or passing through
hazardous areas, the metal screen or armour is to be earthed inside the hazardous area to avoid dangerous potential
between screen armour and earthed part of the installation

2) Cross section of earth connections

Instrumentation &
Communication Cable

Earth connections for metal coverings shall be carried out with conductors having cross sectional areas related to the
cross sectional areas of the phase conductors and the current ratings of the cables, or at least the same cross sectional
areas as the metal covering it self.

3) Earthing through metal clamps etc.

Earthing & Bonding wire

Metal coverings of cables may be earthed through clamps. The clamps must grip the metal covering of the cable and must
be connected to the hull and provide a good conductive connection between the metal covering and the hull. The metal
clamps must be corrosion resistant.

4) Earthing through cable glands

VFD Cable

The metal coverings of cables may be earthed by means of glands intended for the purpose and so designed as to
ensure an effective earth connection. The glands shall be firmly attached to, and in effective electrical contact with, a
metal structure earthed in accordance with these regulations.

5) Earthing of metal pipes, conduits etc.

Offshore Cable

Technical Information

Metal pipes and cable conduits are to be earthed. Pipes and conduits may be earthed by being screwed into a metal
enclosure, or by nuts in both sides of the wall of metallic enclosure, provided that the surface is clean and free from rust,
scale or print.
Comments : For intrinsically safe circuits it is important to separate the earth conductor from the protective earthing.
The resistance between a zener barrier earth and protective earth must be max.
1ohm and preferably less than. 0.1ohm to avoid that possible fault current does not lead to a potential increase in the
system.

87

Halogen free & Mud resistant Offshore cable

Technical Information
6. Fixing of cables
Cables are to be suitably fixed to the supports. In order to guard against the effects of
electrodynamics forces developing on the occurrence of a short circuit, single core cables should
be firmly fixed by using supports of a strength adequate to withstand forces corresponding to the values of prospective
short circuit current.
The requirement concerning fixing can normally be fulfilled when the cables are clamped as follows:
For cables entering enclosures and conduits the nearest clamp is to be placed at a minimum distance from the entry of 10
times the diameter the cable concerned from the entry.
At other points the distance between the clamps must not exceed the in the following table:

External diameter of cable (mm)

Spacing of fixing points (mm)

Above

Up to

Cables without Metal


braid or armor

Cables with copper,


bronze or steel braid
or armor

200

250

13

250

300

12

20

300

350

20

30

350

400

30

400

450

7. Mechanical protection of cables


Cables are to be installed in such a way that they are not subject to damaging mechanical stressed.
where this can not be obtained the cables are to be protected. Unless the cable itself(for example armour or sheath)
provides adequate protection the cables should be:
Enclosed in suitable conduits or casings
covered by steel pipes or profiles
Steel pipes in which the cables are run
in areas where there is an exceptional risk of mechanical damage, for example in cargo hold area or different storage areas,
the cables always have to be protected, even when the cables are armoured.
The thickness of the protective conduits must be at least 4mm.
The wall thickness of the protective conduit must be at least 2mm.
Cables lay on aluminum supports may have a corresponding protection of aluminum.
the thickness must be at least 4mm.
Metal casing used for mechanical protection of cables should be efficiently protected against corrosion.

88

Offshore Cable

Technical Information

NEK-606 (2009), IEC 60092-350, 353, 354, 376

8. Installation of cables for fire properties


HV Power Cable

Cables must at least meet the flame retardant requirements. On board passenger ships, cargo-ships
and mobile offshore units, where requirements are considered to be satisfied if the cables have
characteristics complying withe the cable bunch test IEC-Publication 60332-3, or fire stops are installed in accordance with
the following recommendations:When cable complying with single-cable test, but not the cable-bunch-test, are installed, fire
stops are to be provided in enclosed or semi-enclosed spaces except for cargo rooms and tunnels in cargo areas.
a) For vertical cable runs

LV Power & Lighting Cable

- with a max. distance between fire stops of two decks or 6 meters, unless installed in totally enclosed cable ducts
- at the main and emergency switchboard
- where cables enter into an engine control room
- at centralized control panels for propulsion machinery and essential auxiliaries
- at the entrance to cables ducts

b) For horizontal cable runs.

- Fire stops shall be as specified in item a) above but the maximum. distance between fire stops may be increased to 14m.

Instrumentation &
Communication Cable

When choosing cable types special attention should be paid to reduce possible damage due to corrosion in case of a fire.
Non-halogen free cables(materials)will give off corrosive gases during a fire.
The corrosion effect depends on the amount of halogens in the materials used.
Flame retardant cables are to give characteristics complying with the test requirements in IEC-Publication 60332-1, with
amendments.
Fire resistant cables are to give characteristics complying with the requirements in IEC-Publication 60331.

9. Intrinsically safe installations

Earthing & Bonding wire

Cables and flexible cables for intrinsically safe circuits must have screen or similar of a conducting material and the outer
sheath must be of an insulating material. A non-metallic outer sheath is, however, not required if the screen or armour
consists of a corrosion resistant bronze alloy. Where there is no danger of interference from the external electrical or
magnetic fields, short flexible cables may be used without screen.
a) Associated equipment

Associated equipment(e.g.power supply units) shall be situated in a safe area or has protection as mentioned in "Explosion risk areas."

b) Connection of equipment

Within limitations laid down in 3., ordinary non-explosion protected equipment may be connected to intrinsically safe equipment, provided that it is designed
to meet regulations in other respects.

c) Compliance with any limitations in the certificate

VFD Cable

With intrinsically safe circuits special considerations must be given to ensure that the circuits characteristics (including connected equipment, cables,
conductors etc.) satisfy any limitations in the test certificate.
Such limitations may be maximum values for capacitance and inductance etc. It is pointed out there is a danger of damage to i.s equipment when using
normal equipment for insulation testing

d) Adjacent location
Conductors for i.s safe circuits and conductors for non-i.s safe circuits shall not be run together in the same cable, flexible cable, conduit, cables bunch etc.

e) Protection against electrical and magnetic fields

Technical Information

Where i.s circuits are exposed to magnetic or electrical field that may destroy the intrinsic safety of the system.
Precautions must be taken during installation. Such precautions may be:
- cables for i.s circuits and non-i.s circuits to be installed a minimum distance of 50mm apart.
 The minimum distance to heavy current cables using D.C with a high ripple content should be 300mm.
- cables for i.s circuits and non-i.s circuits to be separated panel of conducting material which is earthed.
- cables for i.s circuits to have effective transposition.

f) Marking

The marking may be a marking plate or by colour marking of the cables when using colour marking, the colour should be light blue.

Offshore Cable

89

Halogen free & Mud resistant Offshore cable

Technical Information
CORE IDENTIFICATION
1. High voltage power cables
The individual cores shall be identified by the colored semi-conducting tape or colored ribbon tape run
longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows:
1 core : Off-white (Grey)
3 core : Off-white (Grey), Black, Red, or Off-white(Grey), Red, Blue

2. Low voltage power and control cables


The insulated cores shall be identified by the color of insulation or by the number printed on insulated
cores; as follows
1) NEK-606 standard
1core : Off-white(Grey) or Black
2core : Off-white, Black
3core : Off-white, Black, Red
4core : Off-white, Black, Red, Blue or Black, Off-white, Red, Green.
5core and above core: white number on black insulation or black number on white insulation
Earth core : Green/Yellow (green base with yellow stripe)
2) CENELEC harmonization document HD 308 S2
2C

3C

Green / Yellow

Blue

Brown

4C

Green / Yellow

Brown

Black

5C

Green / Yellow

Blue

Brown

Black

2C

Blue

Brown

3C

Brown

Black

Grey

Grey

4C

Blue

Brown

Black

Grey

Grey

5C

Blue

Brown

Black

Grey

3. Instrumentation and communication cables


Each pair/triad shall be identified as follows.
- Pairs : Black, Light blue or Black, White
- Triads : Black, Light blue, Brown or Black, White, Red
For identification of multi-pair/triad cables, pair/triad are identified by lapping of the numbered tape or
by the number print directly on the each cores, and the number interval shall be 100mm or less.
The other color scheme may be applicable when purchaser required.

90

Offshore Cable

Black

Technical Information

Handling, Installation Method & Notice

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Loading & Transportation


1. In case of a crane
Should transport by using standard rope and a shaft
which is put in the center of drum.

HV Power Cable
Right

Wrong

LV Power & Lighting Cable

* Matters that requires attention


- Placing it even with the ground.
- Should move slowly and when it placedown, dont do sudden stop.

Shaft

2. In case of a forklift
Drums should not be damaged by a forklift.

Instrumentation &
Communication Cable

* Matters that requires attention:


- Place the drum on the center of a fork.
- The width of a fork should be longer than drum size.

Matters that requires attention while handling cables.


Dont lie drums down.
Dont move it 20m longer when rolling it.
Dont use gimlets or something like sharp when moving.
Dont roll a damaged drum.
Dont roll at projecting surface.
Dont store drum near to stove and heater.

Right

Earthing & Bonding wire

Transportation and Unloading

Wrong

Check point while handling cables(Storage)


VFD Cable

Storage

Technical Information

Dont leave the protecting packing materials and outside package until remove it for setting up cables.
Should construct a fence to protect against damages by moving machines.
Keep it inside or in depository when safekeeping in long term.
(For reference, drums and packages can stand against dry whether outside the house)
Must seal both sides of cables remaining in the drums the cap and heat-contracting tube so that moisture
doesnt soak in after finishing the removal of exterior packing materials and cutting and installing cables.

Offshore Cable

91

Halogen free & Mud resistant Offshore cable

Certificates Approved

Cert. of ISO 9001

Cert. of ISO 14001

Cert. of OHSAS 18001

92

Offshore Cable

BV

GOST-R

Instrumentation &
Communication Cable

DNV

Earthing & Bonding wire

ABS

VFD Cable

LV Power & Lighting Cable

HV Power Cable

Class Type Approval

Technical Information

Technical Information

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Offshore Cable

93

Halogen free & Mud resistant Offshore cable

Memo

94

Offshore Cable

Technical Information

VFD Cable

Earthing & Bonding wire

Instrumentation &
Communication Cable

LV Power & Lighting Cable

HV Power Cable

Technical Information

NEK-606 (2009), IEC 60092-350, 353, 354, 376

Offshore Cable

95

www.tmc-cable.com
Head Office / Ipjang Factory
#368-7, gasan-ri, Ipjang-Myeon, Cheonan-si, Chungnam, Korea
Tel. +82-41-589-6500 Fax. +82-41-589-6400
Bukmyeon Factory
#330-852, Maesong-ri, Buk-Myeon, Cheonan-si, Chungnam, Korea
Tel. +82-41-554-0630 Fax. +82-41-553-7166
Seoul Office
#100-704,13F Danam Building, Namdaemunno 5-ga, Jung-gu, Seoul, Korea
Tel. +82-2-771-3434 Fax. +82-2-771-3003
Geoje Office
KHAN Building 1F, 915 Aju-dong, Geoje-si, Gyeongsangnam-do, Korea
Tel. +82-55-688-5261 Fax. +82-55-688-5262
Dalian Office(China)
Changjiang Office Building No.123 Changjiang Road. Zhongshan District 939/940 Room Dalian,China.
Tel. +86-411-8252-9669, 9769 Fax. +86-411-8269-8316

TMC1309-1000

También podría gustarte