MECHANICAL REFRIGERATION SYSTEM

CLIENT REV PREPARED BY 0 1 2 1 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 DATE APPROVAL W.O. UNIT AREA EQUIP. NO REQUISITION NO. PROCURED BY PAGE SPECIFICATION NO. INSTALLED BY

Service Conditions Capacity Tons Manufacturer Compressor Suction Condenser Refrigerant Flow Cooling Water Supply Cooling Water Requirement Evaporator Refrigerant Evaporator Process Fluid Compressor Driver provided by Refrigerant Model psig F Discharge psig lb/h F F exit lb/h F outlet rpm F F exit psig Process Fluid

psig lb/h

Maximum gpm F F inlet Driver type hp

psig

Temperature Control Level Controls (specify): Pressure Gages:

Specifications Instruments & Controls Elec. Area Classification Connections (flange type): Connection Sizes, inch Inlet Outlet Flanges Rating, psig Face

IP Code Class/Group/Div

Condenser Cooling Water Refrigerant to Evaporator Suction Cross Exchanger Compressor Suction Compressor Discharge Steam Supply Power Supplies Driver Fouling Factors for Cooling Water Condenser Tube Water Velocity Limits Refrigerant Charge

N/A N/A psig F V/Ph/Hz Instruments ft-h-F/Btu Process Fluid ft/s to lb Materials of Construction OD inch Tube Wall Length ft Pitch Channel OD Length inch ft Tube Wall Pitch V/Ph/Hz ft-h-F/Btu ft/s

Condenser

Tubes Number Tube Sheet Furnished by Tubes Number Tube Sheet

BWG BWG

Evaporator

BWG BWG

Channel Notes 1. Vendor to specify make and model for flow, temperature, and pressure control valves; hand valves; thermometers and steam traps; electrical components; and miscellaneous equipment and components.

STEAM JET REFRIGERATION SYSTEM


CLIENT REV PREPARED BY 0 1 2 1 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 DATE APPROVAL W.O. UNIT AREA EQUIP. NO REQUISITION NO. PROCURED BY PAGE SPECIFICATION NO. INSTALLED BY

Type Chilled Water Supply Make-Up Water Booster Jet Stream (a) (b) Secondary Jet Stream (a) (b) Cooling Water psig Fouling Factor for Water

Capacity: lb/h lb/h lb/h lb/h lb/h F

Service Conditions tons | Manufacturer F Return lb/h psig psig psig psig Primary Condenser: Secondary Condenser: ft-h-F/Btu Specifications

Model: lb/h F F F F F lb/h lb/h F

F exit F exit

Steam Hand Valves provided by: Level Controls (specify): Pressure Gages: Connection Sizes, inch Inlet Outlet Flash Tank Chilled Water Make-Up Water Primary Condenser Steam Secondary Condenser Steam Primary Condenser Cooling Water Secondary Condenser Cooling Water Condenser Tube Water Velocity Limits ft/s

Connections (flange type):

Flanges Rating, psig Face

to

ft/s

Flash Tank Booster Ejector Nozzle Primary Tubes Number Tube Sheet Surf Condenser Furnished by Tubes Number Barometric Primary Condenser Shell Baffles Spray Noz

Materials of Construction Corr Allw Barometric Leg Secondary Ejector Nozzles OD inch Tube Wall Length ft Pitch Channel OD Length Corr Allw Corr Allw No. inch Tube Wall ft Pitch Barometric After Condenser Shell Baffles Spray Noz

Corr Allw BWG BWG

BWG BWG Corr Allw Corr Allw No.

Notes 1. Vendor to specify make and model for flow, temperature, and pressure control valves; hand valves; thermometers and steam traps; electrical components; and miscellaneous equipment and components. 2. Flexibility (determines number of booster jets): 3. Temperature extremes and durations of cooling water: 4. Closed or open circuit cooling water: 5. Pumps (by Vendor or Owner; discharge heads if applicable): 6. Space limitations: 7. Cost of utilities (if Vendor required to do economic analysis):