Aboutus Being founded in November 18th 2005 with a registered capital of RMB 30.

67million, Shandong Vicot Air Conditioning Co., Ltd is a hightech corporation specializedinR&D,production,salesandserviceofrenewableenergyproducts. Our production base locates in Solar City, Dezhou, China, its total investment is of RMB 338 million and covers an area of 150,000 with modern workshops and office buildings of more than 80,000 . Manufacturing facilities and capability asfollowings:14electricalACproductionlineswithannualyieldof100,000electrical AC units; 7 gasfired AC production lines for assembly and key components with annual yield of 10,000 gas fired AC units; More than 20 solar collector production equipment with annual yield of 200,000 of collectors; 6 vacuum tube production lines with annual yield of 100,000 pieces of tubes; Annual yield of 10,000 standard sets of solar air conditioning system (20kW/ standard set) and 500 standard sets of solarboilersystem(700kW/standardset).

WehaveISO9001:2008,ISO14001:2004,CE,ETL,CCCcertificates:

Contents

Vicotproductlines...1 Roadmaptoenergyfuture..2 Vicotsolarairconditionersystem....3 Vicotsolarcollector.5 Vicotsolarthermalenergyaccumulator..7 Vicotgasfiredorsolarpoweredaircooledammoniawaterabsorptionchiller9 Specification12

Vicotproductlines

A. Solarenergydriven
1.

Solarboiler Solarairconditioner

2.

B. Naturalgas/LPG/LNGdriven
1.

Gasfiredabsorptionchiller

C. Electricitydriven
1. 2. 3. 4. 5. 6. 7. 8. 9.

Aircooledwaterchiller Watercooledwaterchiller Geothermalheatpump Rooftoppackagedunit Ductedsplitunit Topdischargecondensingunit DXfancoilunit Chilledwaterfancoilunit Airhandlingunit

.1 .

Roadmaptoenergyfuture

Traditional Heating

Solarheating

Solarboiler

Oil,gas,coal electricity

Backup energy

Renewable SolarEnergy

Traditional cooling

Absorption refrigeration

.2 .

Vicotsolarairconditionersystem

Briefintroduction Vicot solar air conditioner, a ChineseAmerican joint development. Three years of collaboration and technology transfer have led to remarkable achievements in solarenergy,scienceandtechnology,yieldingconversionefficienciesforheatingand cooling of up to 85%, solar concentrations 27 times higher than ordinary flat plate collectors for water heating. This solar energy technology will truly contribute to preserving our planet. The GWP<1, ODP=0. The natural refrigerant employed will keepourskiesblueandouraircleantobreathe. Features 1.24hourssolarpowerdrivenairconditioningsystemforcooling,heatingand domestichotwaterwiththermalenergystorage; 2.Capapableofusingexhaustheat,naturalgas,andprocessgastosupplement thesolarenergysupplyordrivethesystemindependentlywhennecessary; 3.Novelconcentratingtroughcollectordesignwithanenergyefficiencyof morethan75%,fourtimestheenergydensityofconventionalwaterheater collector; 3

Vicotsolarairconditionersystem 4.NaturalrefrigerantMR717,noharmtoenvironment; 5.220oCphasechangemoltensaltmaterialforthermalstorage; 6. 3.5 years' payback over conventional electric air conditioner ( in 800W/m2 radiation,3200insolationhours/year); 7.Electricitysavingis417kW.h/m2peryear; (irradiance:800W/m2,thesunlighthourperyear:3200hours) 8.AnnualCO2emissionreductionis370kg/m2. (irradiance:800W/m2,thesunlighthourperyear:3200hours) OperationPID

.4 .

Vicotsolarcollector

Briefintroduction: Vicot solar collector efficiency is higher than 75% at incogitable cost for ordinary people, the Chinese and American scientists and engineers convert the expensive space technology with their genius intelligence into an emerging energy savingeliteforeverypeople. Savingsfigure: 1m2solarcollectorsaves223kgstandardcoalor155m3naturalgas 1m2 solar collector meets the heating demand of construction area up to 20m2 1m2solarcollectorcanhaveannualsteamproductionupto2.89Ton

.5 .

Vicotsolarcollector Features 1. High efficiency >75%, four times of normal solar heater 2.Heattransferoiltemperatureupto350 3.Specialreflectionmirrorforsolarenergy 4.Automaticsunshinetrackingsystem 5.360safetyprotectionsystem 6.Modularstructuredesign 7.Efficienttransportationsimilartoassemblyfurniture 8.Convenientassemblysimilartoassemblyfurniture 9.Designforwithstandingwindofclass10 Solarcollectorcomponents Concentrationmirror Concentration mirror is a parabolic mirror coated with sunlight concentration material. It concentrates the low density sunlight on vacuum tube for producing high temperature. Vacuumheatpipe It's vacuum heat pipe type glass metal heat collection tube. Flexibleinstallation Installation can be made on roof to building, garage or ongroundfloor.

Convenienttransportation Solar collector is modular type design, and can be shipped in knock down condition, the transportation is simple and economic, and site assembly is convenient andflexible.
.6 .

Vicotsolarthermalenergyaccumulator

Briefintroduction: Our Chinese and American scientists and engineers have solved the problem of accumulation of medium high temperature solar energy and realized the dream of having a sun in night sky with their genius intelligence, which is one of the bases for largescaleapplicationofsolarenergy. Features: 1.Highefficientheatexchangedesign 2.Modulardesign 3. Special high temperature thermal storage phase changing material, there are threeoptionalphasechangingpoints160,220 and250. 4.Highthermalstoragedensity 5.Latentheatandsensibleheatstoragecanbeappliedsimultaneously. 6.Strongthermalstoragecapacity

.7 .

Vicotsolarthermalenergyaccumulator Accumulatorstructure

Thermalstoragecurve

.8 .

Vicotgasfiredand/orsolarpoweredaircooledammoniawaterabsorptionchiller

Briefintroduction Vicot gasfired and/or solar powered aircooled ammoniawater absorption chiller is a high efficiency for residential and light commercial air conditioning, based on the highly efficient generatorabsorber heat exchanger (GAX) absorption cycle. AbsorptionPrinciple

.9 .

Vicotgasfiredand/orsolarpoweredaircooledammoniawaterabsorptionchiller Briefintroduction: Vicot gasfired and/or solar powered aircooled ammoniawater absorption chiller is a high efficiency for residential and light commercial air conditioning, based on the highly efficient generatorabsorber heat exchanger (GAX) absorption cycle. Features: 1PatentedTechnologyforFirstEverContinuouslyVariableSpeedOperation. 2 Modulardesignandparallelmultiunitconnectioncanrealize5RT~35RTcapacity. 335TRgroupscanbecentralizedupto175TR. 4IntelligentControlsforLoadMatchingforOptimalEfficiency. 5CanProduceChilledGlycolToTemperaturesof8CforIcemaking. 6Efficientvariablespeedmotorcontroltechnology. 7LowNOxburner,ExtremelyCleanBurning. 8Optionalheatingmoduleforhotwatersupplyin24hours. 9Stableoperationinambienttemperaturefrom20 to55. 10NonToxicCorrosionInhibitorinrefrigerationsystem. 11Thetrueecofriendlyairconditioning. Performancecurve
80000 70000 CoolingCapacityBTU/H 60000 50000 40000 30000 20000 10000 0 50 60 70 80 90 100 110 120 Partload Full load

OutdoorTemperature

.10 .

Vicotgasfiredorsolarpoweredaircooledammoniawaterabsorptionchiller Dimension

Power

Gas(1/2") Water outlet(5/4") Water inlet(5/4")

.11 .

Vicotgasfiredorsolarpoweredaircooledammoniawaterabsorptionchiller Screenshotofprototypeoperatingcondition
Flow (calc)=2.19 [Bt u/lb: 460] R:LV_BETA_H W:LV_BETA_H 08:32 to 08:47 beta 23-030803.bin 08/ 03/2003 T=45.98 Q=60,567 Flow=115.0 T=54.7 T bub=290.6 P=69.5

GAS RATE=86,050 COP =0.7039 CAPACITY =60,567 BETA 23 95 Normal Fire 8/3/2003 8:32 - 8:47

Tbub=36.6

T=232. REFRIGERANT T=145.9 P=267.7 Y=0.9976

T=245.2 T f lue=384.8 SYSTEM CHARGE H2O=17.7 lb NH3=16.5 lb NaOH=46.5 g AG 1100=46.5 g CONTROL CHIP BCH3726Y FAN EC23711B T=94.4 Subcooling=20.2

COM BUSTION ANALYSIS NOx 9ppm O2 5.0% CO 15ppm CO2 9.0% ex air 28.0% eff 98.9%

Generator cutout 262.2

WEAK LIQUOR T=395.8 X=0.0235

AM BIENT=95.8 P gas=14.21 T gas=82.2 Gas Timing = 77.7 mmFIRING=85,365 Electrical Power (W)=834

. 12 .

Specification
Model VSAC005A Item Aircooledammoniawaterabsorptionchiller RT 5 Coolingcapacity kW 18 BTU/h 60,000 RT 2.5~5 Capacity regulation kW 9~18 range BTU/h 30000~60000 Refrigeranttype MR717 3 Waterflowrate m /h 3.1 Dimension(L*W*H) mm
1500*914*1632

VSAC010A

VSAC015A

VSAC020A

10 36 120,000 2.5~10 9~42 30000~120000 6.2


2* (1500*914*1632)

15 54 180,000 2.5~15 9~54 30000~180000 9.3


3* (1500*914*1632)

20 72 240,000 2.5~20 9~72 30000~240000 12.4


4* (1500*914*1632)

Drivingtemperature Powersupply Powerinput Weight Solarcollector Collectorarea Collectoroutput Installationarea Weight Thermalmedia Accumulator Storagecapacity Volume

kW kg m2 kW m2 Kg 105kJ m3

150oC~220oC 220V/1PH/50Hz(pleasecheckwithusfordifferentpowersupply) 0.8 1.6 2.4 3.2 485 970 1455 1940 45 90 25 50 90 180 1800 3600 Mineralheattransferoil 3.6 1.17 7.2 2.34 120 75 240 4800 165 100 330 6600

10.8 3.51

14.4 4.68

Notes: 1.Thetestconditionsoftheunit SolarirradianceQ=1000W/m2,ambienttemperature35oC; 2.Chilledwaterinlettemperature12oC,chilledwateroutlettemperature7oC; 3.Capacityregulationrangeoftheunitistherangeofitssteplessinverter; 4.Thethermalstoragecapacitycanbecustomized; 5.Inthespecialcircumstances,naturalgas/LPG/LNGandhotoilmaybeusedassupplementaryenergy.

. 13 .

Specification
Model VSAC025A Item Aircooledammoniawaterabsorptionchiller RT 25 Coolingcapacity kW 90 BTU/h 300,000 RT 2.5~25 Capacity regulation kW 9~90 range BTU/h 30000~300000 Refrigeranttype MR717 3 Waterflowrate m /h 15.5 5* Dimension(L*W*H) mm
(1500*914*1632)

VSAC030A

VSAC035A

30 108 360,000 2.5~30 9~108 30000~360000 18.6


6* (1500*914*1632)

35 126 420,000 2.5~35 9~126 30000~420000 21.7


7* (1500*914*1632)

Drivingtemperature Powersupply Powerinput Weight Solarcollector Collectorarea Collectoroutput Installationarea Weight Thermalmedia Accumulator Storagecapacity Volume

150oC~220oC
220V/1PH/50Hz(Plscheckwithusfordifferentpowersupply)

kW kg m2 kW m2 kg 105kJ m3

4.0 2425

4.8 2910

5.6 3395 285 175 570 11400

210 240 125 150 420 480 8400 9600 Mineralheattransferoil 18.0 5.85 21.6 7.02

25.2 8.19

Notes: 1.Thetestconditionsoftheunit SolarirradianceQ=1000W/m2,ambienttemperature35oC; 2.Chilledwaterinlettemperature12oC,chilledwateroutlettemperature7oC; 3.Capacityregulationrangeoftheunitistherangeofitssteplessinverter; 4.Thethermalstoragecapacitycanbecustomized; 5.Inthespecialcircumstances,naturalgas/LPG/LNGandhotoilmaybeusedassupplementaryenergy.

. 14 .

Specification
Model VSAC070A VSAC105A VSAC140A VSAC175A Item Aircooledammoniawaterabsorptionchiller RT 70 105 140 175 Coolingcapacity kW 252 378 504 630 BTU/h 840000 1260000 1680000 2100000 RT 2.5~70 2.5~105 2.5~140 2.5~175 Capacity regulation kW 9~252 9~378 9~504 9~630 range BTU/h 30000~840000 30000~1260000 30000~1680000 30000~2100000 Refrigeranttype MR717 3 Waterflowrate m /h 43.4 65.1 86.8 108.5 Dimension(L*W*H) mm 14*(1500*914*163 21*(1500*914*163 28*(1500*914*163 35*(1500*914*163 2) 2) 2) 2) Drivingtemperature oC 150oC~220oC Powersupply 220V/1PH/50Hz(pleasecheckwithusfordifferentpowersupply) Powerinput kW 11.2 16.8 22.4 28 Weight kg 6790 10185 13580 16975 Solarcollector Collectorarea m2 570 840 1125 1410 Collectoroutput kW 350 525 700 875 Installationarea m2 1140 1680 2250 2820 Weight kg 22800 33600 45000 56400 Thermalmedia Mineralheattransferoil Accumulator Storagecapacity 105kJ 50.4 75.6 100.8 126 Volume m3 16.38 24.57 32.76 40.95 Notes: 1.Thetestconditionsoftheunit SolarirradianceQ=1000W/m2,ambienttemperature35oC; 2.Chilledwaterinlettemperature12oC,chilledwateroutlettemperature7oC; 3.Capacityregulationrangeoftheunitistherangeofitssteplessinverter; 4.Thethermalstoragecapacitycanbecustomized; 5.Inthespecialcircumstances,naturalgas/LPG/LNGandhotoilmaybeusedassupplementaryenergy.

. 15 .

VicotSolarairconditioner
Breathingtogether,CoEnergysaving

Specialthanksto:

ChineseAcademyofSciences BeijingSolarEnergyResearchInstitute WuhanUniversityofTechnology FAFCOEnergyStorageDevicesCompany

VicotairconditioningCo.,Ltd. /Add:HongduRd.Dezhoueconomiczone,Shandong/Postalcode253022/ /Tel:+8653182355568/Fax+8653182357911/ /Email:export@vicot.com.cn/ /Http://www.vicot.com.cn/

Nov.2011

The product design is subject to change without prior notice.