Está en la página 1de 2

Data sheet

Lockshield valve type RLV-S - for individual shut-off

Application

RLV-S Straight By means of a lockshield valve, type RLV-S, every radiator can be shut off individually to allow trouble-free maintenance or repair without affecting other radiators in the system. The lockshield valve, type RLV-S, is available in an angle version as well as a straight version. Finish: plain brass or nickel plated. The RLV-S lockshield valves can be preset to limit the max. water flow within the following setting area: RLV-S 10: kvs = 1.5 m3/h RLV-S 15/20: kvs = 2.2 m3/h Factory setting is fully open valve. Dimensions correspond to DIN 3842-1. RLV-S is intended for mounting on the outlet of the radiator.

RLV-S Angle Accessory for RLV-S: - Brass handwheel: a tool which replaces the thermostat when radiators with RLV-S lockshield valves are removed. In order to avoid deposition and corrosion the composition of the hot water must be in accordance with the VDI 2035 guideline (Verein Deutscher Ingenieure). System

RLV-S

Ordering and data


Type Code no. nickel plated 003L0121 003L0122 003L0123 003L0124 003L0125 003L0126 Code no. plain brass 003L0111 003L0112 003L0113 003L0114 003L0115 003L0116 Connections ISO 7-1 Syst. Rad. G 3/8 R 3/8 G 1/2 R 1/2 0.20 0.40 0.60 0.80 1.05 1.25 1.40 G 3/4 R 3/4 1.55 1.70 1.80 2.20 Flow limitation: kv-values (m3/h) for no. of turns 0.25 0.5 0.75 1 1.5 2 0.9 2.5 1.0 3 3.5 4 kvs Max. Max. working Test water press. press. temp.

DN 10 angle DN 10 straight DN 15 angle DN 15 straight DN 20 angle DN 20 straight


1)

0.15 0.30 0.45 0.55 0.75

1.15 1.25 1.35 1.50 10 bar 16 bar 120 C

RLV-S can be connected to PEX, Alupex, steel or copper tubings by Danfoss compression fittings. Product Brass handwheel: Replaces the thermostat temporarily when the radiator is removed Code no. 013G3300

Accessory

Setting and regulation

Setting of max. water flow: - Close the valve by means of an Allen key: DN 10 = 6 mm; DN 15/20 = 8 mm. - Regulate the water flow by opening the valve. The capacity diagrammes on the opposite page show the water flow at - 4 turns and for fully open valve (kvs).

RLV-S

CD-ST

VD.33.V1.02

Danfoss 08/99

Data sheet

Lockshield valve type RLV-S

Design
1. 2. 3. 4. 5. 6. O-ring Cover cap Shut-off spindle Valve body Union nut Nipple

Material in contact with water


Valve body and other metal parts O-ring Ms 58 EPDM

Dimensions

Type RLV-S 10 RLV-S 15 RLV-S 20

D G 3/8 G 1/2 G 3/4

d2 R 3/8 R 1/2 R 3/4

H1 42 52 52

H2 26 28 28

L1 51 53 61

L2 75 80 92

L3 27 30 34

L4 51 57 65

L5 23 27 30

S1 22 27 32

S2 27 30 37

Capacity

[mwg]

[mwg]

CD-ST

VD.33.V1.02

Danfoss 08/99

También podría gustarte