GTP A1800

Elster Metering (P) Ltd

GURANTEED TECHNICAL PARTICULAR FOR A1800 ABT COMPLIANT METERS


S. No. 1. 2. Particulars Characteristics

Manufacturers Name Make & Model No.

Elster Metering (P) Ltd. US Make, ELSTER ( Model : ALPHA A1800)

3.

Type of meter / design designation

Alpha Electronic Static Meter High Precision 0.2s Class ABT Compliant, TOD, microprocessor/ microcontroller based Meters with remote communication facility having 2 Nos simultaneously accessible independent ports & Optical front communication port.

A1800 meter

ANSI/MODBUS protocol with High speed data processing 1200 bps to 28000bps Default Memory 128kB, Optional Expandable Memory upto 1MB

5. 6. 7.

Standard to which meter conform Class of Accuracy Rated Current (Amps.)

IEC 62053-22 / IS14697 0.2 S 1A to 10A (Same meter can be used for Ib ranging from 1A to 5 A) 2 Times Ib For IN 110V(Phase to phase) or 63.5V (Phase to Neutral) 50 Hz 5% 0.7 TO 1.2 Vref 46V to 526V Self Powered from VT supply Optional Auxiliary Supply AC/DC

8. 9. 10. 11. 12.

Rated maximum current as percentage of basic. Rated voltage (Volts) Rated frequency (Hz) Specified operating voltage range Enhanced Voltage Range Auxiliary Supply

13. a b c d e

SERVICE CONDITIONS Maximum Ambient Air Temperature Minimum Ambient Air Temperature Average Daily Ambient Air Temperature Maximum Relative Humidity Max. Altitude above mean sea level (m)

More than 85 C ( inside meter cover) Below 0 C 40 C 10 to100% 1000

GTP A1800 f Average Annual Rainfall (mm) g 14. a) (i) (ii) b) Seismic level POWER CONSUMPTION Power consumption in voltage circuit at rated current Active in watts Apparent in VA Power consumption in current circuit (in VA) at rated current Current that meter is capable of carrying continuously without injury to the meter (Amp.). Short time over current capability of the meter (for duration of 0.5 second) Percentage minimum current which will start the meter and continue to run thereafter at rated percentage and unity power factor (% of basic current) Type of material along with its thickness or dimensions (in mm) and details of the important components parts of the meter. Case Terminal covers Terminals TOD requirement

Elster Metering (P) Ltd 1450 0.3g

As per IS Less than 1.0W Less than 10VA Less Than 1.0VA

15.

----------200% Ib-----

16. 17.

20 Ib 0.1 percent of basic current

18.

Standards as per IP54

a) b) c) 19

High grade engineering plastic High grade engineering plastic High grade engineering plastic Programmable 132 TOD Switch times, 12 seasons, 4 Rates

20 a) b)

Load Profile Load profile interval Load Survey Parameters Energy parameters Demand

1-60 minutes Programmable as per the requirement 8 Energy Values kWh, KVAh, KVARH for Import & Export 6 Demands: kW, kVA, kVAR for Import & export.

Instrumentation Parameters

3Voltages, 3 Currents , Avg Frequency, (All Selectable by Customer before programming)

GTP A1800 c) Load Survey Storage Days

Elster Metering (P) Ltd More than 65 days Depends on No of Channels for Load Survey & instrumentation For 15 minutes interval.

d).

Instrumentation Profile (Selectable) System KW KVar KVA PF PF angle Line Frequency

32 nos. of Instrumentation Parameters Programmable as per customer requirements from the following: Phase A, B or C Current Voltage KW KVar KVA Voltage angle Current angle Harmonic % THD

21

Midnight values for last 35 days 1. net kWh (del.-rec.) 2. net KVARh high 3. net KVARh low 4. net KVARh between 5. net KVARh stayput

5 Energy Values ( Parameters are selectable from the list given by the Customer before programming)

22

ABT KVARh Based on Voltage condition

5 Energy Values (Selectable by Customer before programming)

23 25

Billing History Communication Ports Optional ANSI Protocol MODBUS protocol

Previous 12 Months Billing History 1 no Optical Port 1 no.- RS485 Port with MODBUS 1 no RS485/RS232 port (Optional)

GTP A1800 26 Relay/Pulse Output on front

Elster Metering (P) Ltd 4 Relay Outputs programmable as per customer requirements LED Pulse output for kWh & kVARh

24

Display Parameters-64 Parameters Programmable as per list given kVARh (Q2 - Q3) kVARh (Q2 + Q3) kVARh (Q3 - Q2) kVARh delivered (Q1 + Q2) kVARh net kVARh Q1 kVARh Q2 kVARh Q3 kVARh Q4 kVARh received (Q3 + Q4) kVARh sum kWh delivered kWh net kWh received kVA delivered kVA received kVAr delivered kVAr received Current Billing Energy values TOD Rate wise with Four Rates

(Selectable from the following Parameters before programming) kVAh delivered (Q1 + Q4) kVAh Q1 kVAh Q2 kVAh Q3 kVAh Q4 kVAh received (Q2 + Q3) kVAh sum kVARh (Q1 - Q4) kVARh (Q1 + Q4) Frequency Average PF delivered Average PF received THD for Voltages THD for Currents kW delivered KW received ABT odometric energy values Date & Time Demand reset counts

For Elster Metering (P) Ltd.

SREEKANTH.S.V Asst. Manager- Sales