05-349-952-34-05

For Residential, Light Commercial, and Snowmelt Applications

Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location ––––––––––––––––––––––––––––––––––––––––– Approval –––––––––––––––––––––––––––––––––––––––––––––


Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––

Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––

HydroNex P-Series Panel


Sizes: 1-1/4" Trunk
P-Series Panels are primary panels designed to supply
down-stream panels with boiler water, which will in turn
distribute boiler water to the radiant or other hydronic heating
zones. They also remove air and provide essential service
and monitoring capabilities. They are available with or without
outdoor boiler reset controls and auto-fill assemblies.

D-Series and P-Series panels include only the supply portion


of the primary loop. The return portion of this loop must always
be field piped in 1-1/4” copper back to the boiler or dedicated
heat source.

All P-Series panels are designed to connect directly to any


D-Series panel via the included union. Control logic is
transferred from the D-Series panels to the P Panel via the
included CAT5 cable connection.

Optional accessories include auto-fill assembly (shown) and


a boiler reset module. Reset should not be used if using an
injection D Series panel as these already contain a reset feature
on the included Tekmar 361. Features
– Wall mounted white powder coated back panel and cover.
Installation – Easy access to all components.
Make sure an electrical outlet is within 3 feet of where the – Pre-wired circulators and controls.
P-Series panel will mount. If there are no outlets nearby, one will – Simple CAT 5 jump wiring to connect panels.
need to be added. – Single union connection between panels.
– Integrated leveling system.
Install and level Z-Bracket with 1/4” x 2-1/2” lag screw to studs. – Z-Bracket for simplified mounting.

Hang the P-Series panel on the Z-Bracket. Optional lag screws


may be added to the bottom of the panel, further securing the Specifications
panel to the wall. Supply Voltage . . . . . . . . . . . 120 Volts
Circulator Type. . . . . . . . . . . . Watts Radiant 15-58
Hang cover from top down.
. . . . . . . . . . . . . . . . . . . Taco 008, 0011
If using injection mixing D-Series panel, do not use reset on the . . . . . . . . . . . . . . . . . . . Bell and Gossett NRF-22, PL-30
P-Series panel. Fill Assembly . . . . . . . . . . . . . Manual Only
. . . . . . . . . . . . . . . . . . . Manual and Autofill
Refer to the installation manual for further details. Electrical . . . . . . . . . . . . . . . . Relay and CAT 5 Connection
Reset Control . . . . . . . . . . . . Tekmar 256

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials
without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Hydronex P-Series with a manual fill assembly. Hydronex P-Series with an autofill and manual fill assemblies.

Product Options

Qty. Description Part # Order # Panel Size


P Panel, Manual Fill, Watts Radiant 15-58 Pump PManWR1558 81005806 28” x 31.5”
P Panel, Manual Fill, Taco 008 Pump PManTA008 81005808 28” x 31.5”
P Panel, Manual Fill, Taco 0011 Pump PManTA0011 81005809 28” x 31.5”
P Panel, Manual Fill, Bell & Gossett NRF-22 Pump PManBGNRF22 81005810 28” x 31.5”
P Panel, Manual Fill, Bell & Gossett PL-30 Pump PManBGPL30 81005811 28” x 31.5”
P Panel, Auto Fill, Watts Radiant 15-58 Pump PAutoWR1558 81005800 28” x 31.5”
P Panel, Auto Fill, Taco 008 Pump PAutoTA008 81005802 28” x 31.5”
P Panel, Auto Fill, Taco 0011 Pump PAutoTA0011 81005803 28” x 31.5”
P Panel, Auto Fill, Bell & Gossett NRF-22 Pump PAutoBGNRF22 81005804 28” x 31.5”
P Panel, Auto Fill, Bell & Gossett PL-30 Pump PAutoBGPL30 81005805 28” x 31.5”

P Panel, Manual Fill, Outdoor Reset, Watts Radiant 15-58 Pump PManRWR1558 81005895 28” x 31.5”
P Panel, Manual Fill, Outdoor Reset, Taco 008 Pump PManRTA008 81005896 28” x 31.5”
P Panel, Manual Fill, Outdoor Reset, Taco 0011 Pump PManRTA0011 81005897 28” x 31.5”
P Panel, Manual Fill, Outdoor Reset, Bell & Gossett NRF-22 PManRBGNRF22 81005898 28” x 31.5”
P Panel, Manual Fill, Outdoor Reset, Bell & Gossett PL-30 PManRBGPL30 81005899 28” x 31.5”
P Panel, Auto Fill, Outdoor Reset, Watts Radiant 15-58 Pump PAutoRWR1558 81005900 28” x 31.5”
P Panel, Auto Fill, Outdoor Reset, Taco 008 Pump PAutoRTA008 81005901 28” x 31.5”
P Panel, Auto Fill, Outdoor Reset, Taco 0011 Pump PAutoRTA0011 81005902 28” x 31.5”
P Panel, Auto Fill, Outdoor Reset, Bell & Gossett NRF-22 PAutoRBGNRF22 81005903 28” x 31.5”
P Panel, Auto Fill, Outdoor Reset, Bell & Gossett PL-30 PAutoRBGPL30 81005904 28” x 31.5”

USA: 4500 East Progress Place, Springfield, MO 65803; www.wattsradiant.com


Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca

05-349-952-34-05 © Watts Radiant, 2006