ALLOWABLE NOZZLE LOADINGS


Allowable nozzle loadings for pressure vessels and shell and Tube Heat Exchangers fabricated from ferrous material shall be as per the
requirements of "Standard nozzles load tables"
Standard nozzles loadings for items designed according to ASME VIII Div. 1 or 2, shall be in accordance with Table 1.
Standard nozzle loadings for items designed to PD 5500 shall be in accordance with Table 2.
Nozzle loadings shall be considered as being caused by 67 % thermal and 33 % dead weight load.
Nozzle loadings for oblique nozzles or tangential nozzles (1) shall be calculated individually. The supplier shall be notified of these loadings
at the time of enquiry.
(1) When angle between the axis of the nozzle and the line normal to the shell/head surface

exceed 45.

VESSEL AND SHELL & TUBE HEAT EXCHANGER ALLOWABLE FORCES & MOMENTS FOR ASME VIII DIV.1 or 2
150LB & 300LB FLANGE RATING

600LB FLANGE RATING

900LB FLANGE RATING

1500LB FLANGE RATING

NOZZLES

OUTSIDE

SIZE

DIAMETER

IN.

mm

FL

FA

FC

MC

MT

ML

FL

FA

FC

MC

MT

ML

FL

FA

FC

MC

MT

ML

FL

FA

FC

MC

MT

ML

2
3

60,33
88,90

3,3
4,9

3,3
4,9

2,5
3,7

0,4
0,9

0,6
1,3

0,5
1,1

3,8
5,6

3,8
5,6

2,9
4,2

0,5
1,0

0,7
1,5

0,6
1,3

4,3
6,3

4,3
6,3

3,2
4,7

0,5
1,1

0,8
1,7

0,7
1,4

4,8
7,0

4,8
7,0

3,6
5,3

0,6
1,2

0,8
1,8

0,7
1,6

114,30

6,3

6,3

4,7

1,4

2,1

1,8

7,2

7,2

5,4

1,6

2,4

2,1

8,1

8,1

6,1

1,8

2,7

2,4

9,0

9,0

6,8

2,0

3,0

2,6

168,28

9,3

9,3

7,0

3,1

4,6

4,0

10,6

10,6

8,0

3,5

5,3

4,6

11,9

11,9

8,9

4,0

5,9

5,1

13,3

13,3

9,9

4,4

6,6

5,7

FORCES KN

MOMENTS KNm

FORCES KN

MOMENTS KNm

FORCES KN

MOMENTS KNm

FORCES KN

MOMENTS KNm

219,08

12,1

12,1

9,1

5,2

7,8

6,8

13,8

13,8

10,4

6,0

8,9

7,7

15,5

15,5

11,6

6,7

10,0

8,7

17,3

17,3

12,9

7,4

11,2

9,7

10

273,05

15,1

15,1

11,3

8,1

12,1

10,5

17,2

17,2

12,9

9,2

13,9

12,0

19,4

19,4

14,5

10,4

15,6

13,5

21,5

21,5

16,1

11,6

17,3

15,0

12

323,85

17,9

17,9

13,4

11,4

17,1

14,8

20,4

20,4

15,3

13,0

19,5

16,9

23,0

23,0

17,2

14,6

21,9

19,0

25,5

25,5

19,1

16,3

24,4

21,1

14

355,60

19,6

19,6

14,7

13,7

20,6

17,8

22,4

22,4

16,8

15,7

23,5

20,4

25,2

25,2

18,9

17,6

26,5

22,9

28,0

28,0

21,0

19,6

29,4

25,5

16

406,40

22,4

22,4

16,8

17,9

26,9

23,3

25,6

25,6

19,2

20,5

30,7

26,6

28,8

28,8

21,6

23,0

34,6

30,0

32,0

32,0

24,0

25,6

38,4

33,3

18

457,20

25,2

25,2

18,9

22,7

34,0

29,5

28,8

28,8

21,6

25,9

38,9

33,7

32,4

32,4

24,3

29,2

43,7

37,9

36,0

36,0

27,0

32,4

48,6

42,1

20

508,00

28,0

28,0

21,0

28,0

42,0

36,4

32,0

32,0

24,0

32,0

48,0

41,6

36,0

36,0

27,0

36,0

54,0

46,8

40,0

40,0

30,0

40,0

60,0

52,0

24

609,60

33,6

33,6

25,2

40,3

60,5

52,4

38,4

38,4

28,8

46,1

69,1

59,9

43,2

43,2

32,4

51,8

77,8

67,4

48,0

48,0

36,0

57,6

86,4

74,9

26

660,40

36,4

36,4

27,3

47,3

71,0

61,5

41,6

41,6

31,2

54,1

81,1

70,3

46,8

46,8

35,1

60,8

91,3

79,1

52,0

52,0

39,0

67,6

101,4

87,9

28

711,20

39,2

39,2

29,4

54,9

82,3

71,3

44,8

44,8

33,6

62,7

94,1

81,5

50,4

50,4

37,8

70,6

105,8

91,7

56,0

56,0

42,0

78,4

117,6

101,9

30

762,00

42,0

42,0

31,5

63,0

94,5

81,9

48,0

48,0

36,0

72,0

108,0

93,6

54,0

54,0

40,5

81,0

121,5

105,3

60,0

60,0

45,0

90,0

135,0

117,0

32

812,80

44,8

44,8

33,6

71,7

107,5

93,2

51,2

51,2

38,4

81,9

122,9

106,5

57,6

57,6

43,2

92,2

138,2

119,8

64,0

64,0

48,0

102,4

153,6

133,1

34
36

863,60
914,40

47,6
50,4

47,6
50,4

35,7
37,8

80,9
90,7

121,4
136,1

105,2
117,9

54,4
57,6

54,4
57,6

40,8
43,2

92,5
103,7

138,7
155,5

120,2
134,8

61,2
64,8

61,2
64,8

45,9
48,6

104,0
116,6

156,1
175,0

135,3
151,6

68,0
72,0

68,0
72,0

51,0
54,0

115,6
129,6

173,4
194,4

150,3
168,5

NOTES
1. All forces and moments in the above table are positive and
sign notation is as per WRC bulletin 107.
The most stringent case caused by axial load 'FA' acting
inward or outward shall be considered.
2. The supplier shall ensure that all process nozzles shall be
suitable for the nozzle loads shown in the above table and
provide the necessary local calculations in accordance with
WRC bulletin 107 and ASME code.
3. All forces and moments act on the intersection of the
axis with the mid-thickness of the shell or head plates
4. The supplier shall notify the contractor of cases where calculations
require an increase in thickness of the reinforcing greater than
construction code and/or guide drawing mini.allowable thicknesses.
In such cases,if notified at the time of quotation,the standard
load may be reduced by the contractor upon written request
by the supplier.Such agreed specific load shall be indicated on the
equipment guide drawing.
5. All cost for the above reinforcement must be included in the
suppliers price.

6.

LOADING NOMENCLATURE
Forces:
Moments:
FL=Longitudinal
ML=Longitudinal
FA=Axial
MT=Torsional
FC=Circumferential
MC=Circumferential

7.

For spheres and heads


Resultant shear force:
F=

( FL +FC )

Resultant bending
moment:
M= ( ML +MC )