Documentos de Académico
Documentos de Profesional
Documentos de Cultura
300MW
20 MPa
GLP
sobrecalentado
338
0.6
26
P6
= 18
P5
k 1
P6 k
T6
=
P
T5
5
T5 = 299 K ( dato)
T6 = 682.84 K
T6 T5
T6 R T5
T6 R = 725.5 K
P7 K exp
T7
=
P
T8
8
P6 = P7 = 10.8
P8 = 0.6bar
Asumo: T7 = 1000 K
T8 = 513.24 K
T7 T8 R
T7 T8
T8 R = 537.6 K
Cpa=1.0035KJ/Kg*K
Wneto=Wturb Wcomp
Wneto = Cpg (T7 T8 R ) Cpa(T6 R T5 )
Wneto = 113.96
KJ
Kg
Qa = Cpg ( T7 T8 R )
Qa = 541.93
5. Flujo de combustible y aire:
Pce=49.37MJ/Kg
Se tiene que:
Qa * m g = ncomb * mc * Pcc
Asumiendo : ncomb = 90%
Kg
s
Kg
m g = 350
s
mc = 4.268
nbomba = 0.75
nturbina = 0.8
Como sabemos:
Salida:
s 3 = s 4 = 6.656 KJ / Kg
P4 = 60 KPa
X = 0.87(calidad )
T4 = 358 K
h4 = 2353KJ / Kg
T3 T4 R
T3 T4
T4 R = 416.2 K
entonces :
h4 R = 3278.6 KJ / Kg
Tsat = T4 = 358 K
h f = h1 = 355.88 KJ / Kg
s f = s1 = 1.1342
s1 = s 2
En la salida:
Tablas para liquido sub enfriado:
h2 = 402.2 KJ / Kg
T2 = 363 K
4. Entalpia real h6 R :
nbomba = 0.75
nbomba =
h2 h1
h2 R h1
h2 R = 417.64 KJ / Kg
T2 R = 366 K
Wneto = ( h3 h4 R ) ( h2 R h1 )
Wneto = 332.64 KJ / Kg
m vapor =
n planta
Ptv
* n gen * Wneto
m vapor = 56.6 Kg / s
7. En el recuperador( n=0.85 )
Temperatura a la salida de recuperador: T9 = 299 K
Calor del recuperador:
Q = maire * Cp * (T8 R T9 ) * n
Q = 71231.94 KW
8. En el caldero (n=0.85)
Qcaldero
113021.4
=
= 141276.75 KW
n
0.8
m combustible =
141276.75
= 2.8 Kg / s
49371.2
nG / V =
PnetaG / V
m* PCI GLP
160 MW
(4.268 + 2.8) * 49.3712
nG / V = 45.6%