Documentos de Académico
Documentos de Profesional
Documentos de Cultura
COMPANYCOMPANY - Background
Founded: Management: 2001 Extensive experience from suppliers Ericsson, Nokia, Lucent, MSI, Allgon, LGP and Powerwave Stockholm, Sweden
Location:
COMPANYCOMPANY - Facilities
Visby
25 24 23 22 21 20 19 18 17 16 15 30
CellMax CellMax
35
40
45
50
55
60
65
70
dBi
12 15
12 15 18
12 15 18
12 15 18 21 24
12 15 18 21 24 >24
50 CellMax 21dBi Antenna sites Coverage C probability b bilit i increased d signifficantly with 24% fewer sites
Data rate is NOT limited by technology, but by received power / interference ratio
1M
UMTS
100k 10K
Indoor local Wide area
After
17 Erl.
54% increase
30% increase
Antenna swap
7.5 km
11 km
The nodeB subject to the change antenna is indicated in figure with one arrow. Configuration RF has not been changed in the period considered for the tests (weeks 49 and 50) Sctors CPICH Qqualmin 48911 35 dBm -22 22 dB 48912 33 dBm -22 dB 48913 34 dBm -22 dB 48914 35 dBm -22 dB 48915 34 dBm -22 dB 48916 34 dBm -22 22 dB
70, 0
60, 0
50, 0 21 dB i 18 dB i 40, 0
30, 0
20, 0
10, 0
ANTENNA - CMACMA-B/6521
Freq. Band: Gain [dBi]: HBW: VBW: VSWR: Isolation: F/B: USLS: 1st Null Fill: XPD: LxWxD (mm): 1710 - 2170 MHz 20.4 / 20.7 / 21.2 66.0o / 65.0o / 63.5o 4.6o / 4.2o / 3.9o < 1.5:1 >30dB >25dB >18dB <20dB >20dB (10dB 60o 2060 x 196 x 92
Nullfill
5 % range increase
Design Criteria
ANTENNA - CMACMA-B/3324
Freq. Band: Gain [dBi]: HBW: VBW: VBW VSWR: Isolation: F/B: USLS: 1st Null Fill: XPD: LxWxD L W D( (mm): ) 1710 - 2170 MHz 23.2 / 23.6 / 24.0 35o / 33o / 31o 4.6 4 6o / 4 4.2 2o / 3 3.9 9o < 1.5:1 >30dB 30dB >30dB >18dB <20dB >20dB (10dB 30o) 2070 x 288 x 128
Environmental Testing
Specification of Environmental Tests for Telecommunications Equipment: ETSI 300 019-2-4: Class T4-1E Non-weather protected locations Extended. ETSI 300 019-2-1: Class T1.2 Weather protected locations - not temperature controlled. ETSI 300 019-2-2: Class T2.2 Careful transportation. p
Environmental Tests
IEC68-2-1 Environmental Testing Part 2: Tests Tests Ab: Cold IEC68-2-2 Environmental Testing Part 2: Tests Tests Bb: Dry Heat IEC68-2-14 Environmental Testing Part 2: Tests Test Nb: Change of Temperature IEC68-2-30 Environmental Testing Part 2: Tests Test Db: Damp Heat, Cyclic IEC68 IEC68-2-52 2 52 Environmental Testing Part 2: Tests Test Kb: Salt Mist Mist, Cyclic IEC68-2-6 Environmental Testing Part 2: Tests Test Fc: Vibration (Sinusoidal) IEC68-2-29 Environmental Testing Part 2: Tests Test Eb: Bump IEC68-2-18 Environmental Testing Part 2: Tests Tests Rb: Water IEC68-2-32 Environmental Testing Part 2: Tests Test Ed: Free Fall (Procedure 1) IEC68 IEC68-2-56 2 56 Environmental Testing Part 2: Tests Test Cb: Damp Heat
Conclusion
Increased efficiency:
up to 30 % increase in coverage 30 % fewer sites cost optimized RF chain antenna position on mast mast, size and wind loading and cost of tower site power and cooling swifter ift roll-out ll t Fewer transmission hops
Reduced CAPEX:
Conclusion - Cont
Increased Traffic: 30% or more increase in revenue improved indoor penetration improved call-set up longer mean holding times of calls increased traffic reduced interference, i increase of fd data t th throughput h t Thanks to reduced number of sites (site rental, utilities, service org. etc)
Reduced OPEX:
Thank You