Está en la página 1de 42

FECHA

5/19/2010
5/19/2010
5/19/2010
5/19/2010
4/19/2010
4/19/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/9/2010
3/25/2009
3/25/2009
3/25/2009
3/25/2009
3/25/2009
3/25/2009
3/25/2009
3/25/2009
3/25/2009
6/29/2007
6/29/2007
6/29/2007
6/29/2007
6/29/2007
6/29/2007
6/29/2007
6/29/2007
6/29/2007
6/29/2007
6/29/2007
6/29/2007

CODIGO
C01U01G007
C01U02G007
C01U03G007
C01U04G007
C01U01G059
C01U02G059
C01U04G023
C01U05G023
C04U01G035
C04U02G035
C04U03G035
C04U04G035
C04U05G035
C04U06G035
C04U07G035
C04U08G035
C03U01G035
C03U02G035
C03U03G035
C03U04G035
C03U05G035
C03U06G035
C05U01G035
C05U02G035
C05U03G035
C05U04G035
C05U05G035
C05U06G035
C05U07G035
C05U08G035
C05U09G035
C01U01G035
C01U02G035
C01U03G035
C01U04G035
C01U05G035
C01U06G035
C02U01G035
C02U02G035
C02U03G035
C02U04G035
C02U05G035
C02U06G035

Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad
Unidad

NOMBRE INSTALACION
1 Central Sauce Andes
2 Central Sauce Andes
3 Central Sauce Andes
4 Central Sauce Andes
1 Central Loma Los Colorados
2 Central Loma Los Colorados
4 Central Los Morros
5 Central Los Morros
1 Central Monte Patria
2 Central Monte Patria
3 Central Monte Patria
4 Central Monte Patria
5 Central Monte Patria
6 Central Monte Patria
7 Central Monte Patria
8 Central Monte Patria
1 Central Punitaqui
2 Central Punitaqui
3 Central Punitaqui
4 Central Punitaqui
5 Central Punitaqui
6 Central Punitaqui
1 Central Chilo
2 Central Chilo
3 Central Chilo
4 Central Chilo
5 Central Chilo
6 Central Chilo
7 Central Chilo
8 Central Chilo
9 Central Chilo
1 Central Constitucin 1
2 Central Constitucin 1
3 Central Constitucin 1
4 Central Constitucin 1
5 Central Constitucin 1
6 Central Constitucin 1
1 Central Maule
2 Central Maule
3 Central Maule
4 Central Maule
5 Central Maule
6 Central Maule

EMPRESA
GESAN
GESAN
GESAN
GESAN
KDM ENERGIA S.A.
KDM ENERGIA S.A.
CELMSA
CELMSA
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION
ELEKTRA GENERACION

COMENTARIO
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Nueva Instalacin
Nueva Instalacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Actualizacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin
Nueva Instalacin

CODIGO EMPRESAS

Cdigo

Agrega Info
Agrega Info

G001
G007
G012
G018
G022
G023
G031
G035
G040
G044
G045
G046
G053
G054
G055
G056
G057
G060
G063
G064
G065
G068
G069
G070
G071
G072
G080
G081
G083
G084
G085
G086
G090
G091

Coordinado
HASA
GESAN
SOCIEDAD CANALISTAS DEL MAIPO
SAGESA
CARBOMET
CELMSA
TECNORED
ELEKTRA GENERACION
PUCLARO
EL MANZANO
NUTRECO
CEN
CRISTALERIAS TORO
ENERBOSCH S.A
HIDROELEC S.A.
ORAFTI
SGA
HIDROPALOMA S.A.
HIDROELECTRICA TRUENO
ON-GROUP
ENERGIA COYANCO
CGI-IANSA
GENERHOM
HIDROELECTRICA DONGO
HIDROLIRCAY
GANADERA Y FORESTAL CARRAN
DONGUIL ENERGA
CAEMSA
HIDROELECTRICA MALLARAUCO
HIDROELECTRICA DIUTO
HIDROELECTRICA MUCHI
LA ARENA SPA
HIDRONALCAS
HIDROCALLAO

Giro
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin
Generacin

UNIDADES GENERADORAS PMG


Favor incluir la velocidad nominal de la unidad y revisar los valores de las inercias de las mquinas respecto

Cdigo Unidad

Propietario

Nombre Central

Unidad

C01U01G046

CEN

Maule

C01U02G046

CEN

Maule

C01U03G046

CEN

Maule

C01U04G046

CEN

Maule

C01U05G046

CEN

Maule

C01U06G046

CEN

Maule

C05U01G035

ELEKTRA GENERACION

Chilo

C05U02G035

ELEKTRA GENERACION

Chilo

C05U03G035

ELEKTRA GENERACION

Chilo

C05U04G035

ELEKTRA GENERACION

Chilo

C05U05G035

ELEKTRA GENERACION

Chilo

C05U06G035

ELEKTRA GENERACION

Chilo

C05U07G035

ELEKTRA GENERACION

Chilo

C05U08G035

ELEKTRA GENERACION

Chilo

C05U09G035

ELEKTRA GENERACION

Chilo

C01U01G035

ELEKTRA GENERACION

Constitucin 1

C01U02G035

ELEKTRA GENERACION

Constitucin 1

C01U03G035

ELEKTRA GENERACION

Constitucin 1

C01U04G035

ELEKTRA GENERACION

Constitucin 1

C01U05G035

ELEKTRA GENERACION

Constitucin 1

C01U06G035

ELEKTRA GENERACION

Constitucin 1

C05U01G012

SOCIEDAD CANALISTAS DEL MAIPO

El Rincn

C04U01G012

SOCIEDAD CANALISTAS DEL MAIPO

Eyzaguirre

C01U01G031

TECNORED

Concn

C01U02G031

TECNORED

Concn

C01U03G031

TECNORED

Concn

C07U01G031

TECNORED

El Totoral

C07U02G031

TECNORED

El Totoral

C07U03G031

TECNORED

El Totoral

C02U01G031

TECNORED

Las Vegas

C02U02G031

TECNORED

Las Vegas

C09U01G031

TECNORED

Linares Norte

C06U01G031

TECNORED

Placilla

C06U02G031

TECNORED

Placilla

C06U03G031

TECNORED

Placilla

C05U01G031

TECNORED

Quintay

C05U02G031

TECNORED

Quintay

C05U03G031

TECNORED

Quintay

C08U01G031

TECNORED

San Gregorio

C01U01G071

HIDROLIRCAY

Mariposas

Nota:
(*) Para facilitar la identificacin de los nuevos campos incluidos, stos se encuentran destacados con un color diferente .

res de las inercias de las mquinas respecto de las unidades de medidas sealadas en las columnas S, T, U y V.

Tipo de Unidades

Combustible

Tipo de
Turbina

Potencia Bruta

Consumos
Propios

Potencia Neta
Efectiva

Potencia Mnima
Tcnica

[MW]

[%]

[MW]

[MW]

Trmica

Diesel

1.50

0.00%

1.50

0.25

Trmica

Diesel

1.50

0.00%

1.50

0.25

Trmica

Diesel

0.75

0.00%

0.75

0.13

Trmica

Diesel

0.75

0.00%

0.75

0.13

Trmica

Diesel

0.75

0.00%

0.75

0.13

Trmica

Diesel

0.75

0.00%

0.75

0.13

Trmica

Diesel

1.00

0.00%

1.00

0.50

Trmica

Diesel

1.00

0.00%

1.00

0.50

Trmica

Diesel

1.00

0.00%

1.00

0.50

Trmica

Diesel

1.00

0.00%

1.00

0.50

Trmica

Diesel

1.00

0.00%

1.00

0.50

Trmica

Diesel

1.00

0.00%

1.00

0.50

Trmica

Diesel

1.00

0.00%

1.00

0.50

Trmica

Diesel

1.00

0.00%

1.00

0.50

Trmica

Diesel

1.00

0.00%

1.00

0.50

Trmica

Diesel

1.50

0.00%

1.50

0.25

Trmica

Diesel

1.50

0.00%

1.50

0.25

Trmica

Diesel

1.50

0.00%

1.50

0.25

Trmica

Diesel

1.50

0.00%

1.50

0.25

Trmica

Diesel

1.50

0.00%

1.50

0.25

Trmica

Diesel

1.50

0.00%

1.50

0.25

Pasada

Francis/Flujo Cruzado

0.30

0.25%

0.30

0.07

Hidrulica Pasada

Banki

1.80

0.00%

1.80

0.30

Trmica

Diesel

1.12

0.00%

1.12

0.34

Trmica

Diesel

0.80

0.00%

0.80

0.24

Trmica

Diesel

0.80

0.00%

0.80

0.24

Trmica

Diesel

1.20

0.00%

1.20

360.00

Trmica

Diesel

1.20

0.00%

1.20

360.00

Trmica

Diesel

0.80

0.00%

0.60

195.30

Trmica

Diesel

1.12

0.00%

1.20

0.36

Trmica

Diesel

1.20

0.00%

1.12

0.34

Trmica

Diesel

0.48

0.00%

0.48

0.40

Trmica

Diesel

1.20

0.00%

1.20

360.00

Trmica

Diesel

1.20

0.00%

1.20

360.00

Trmica

Diesel

0.80

0.00%

0.60

195.30

Trmica

Diesel

1.20

0.00%

1.20

360.00

Trmica

Diesel

1.20

0.00%

1.20

360.00

Trmica

Diesel

0.80

0.00%

0.60

195.30

Trmica

Diesel

0.48

0.00%

0.48

0.40

6.30

0.25%

6.28

1.20

Hidrulica Pasada

CAT (Kaplan)

destacados con un color diferente .

Tasa de
Indisponibilidad
Forzada

Tasa de
Indisponibilidad
Forzada en Hora
Punta (*)

Tasa de
Indisponibilida
d Programada

Tensin
Nominal

[hrs/ao]

[hrs/ao]

[hrs/ao]

[kV]

24

10

10

360

Factor de
Potencia
Nominal

Mtodo de
Conexin del
Neutro a Tierra

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

12.00

0.95 YN

2.20

1.00 YN

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

0.38

0.95

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

0.38

0.95

6.60

0.90 YN

Velocidad
Nominal

[RMP]

Constante de
Inercia

Factor

Factor

Reactancia
sincrnica de
eje directo

Reactancia
sincrnica de
eje en
cuadratura

Reactancia de
secuencia cero

GD2

WR2

Xd

Xq

Xo

[s]

[kg m2]

[lb ft2]

[p.u.]

[p.u.]

[p.u.]

1500

2.99

1.413

0.01

1500

2.99

1.413

0.01

1500

2.83

1.395

0.06

1500

2.83

1.395

0.06

1500

2.83

1.395

0.06

1500

2.83

1.395

0.06

1500

3.17

1.51

0.01

1500

3.17

1.5131

0.01

1500

3.17

1.5131

0.01

1500

3.17

1.5131

0.01

1500

3.17

1.5131

0.01

1500

3.17

1.5131

0.01

1500

3.17

1.5131

0.01

1500

3.17

1.5131

0.01

1500

3.17

1.5131

0.01

1500

2.99

1.413

0.01

1500

2.99

1.413

0.01

1500

2.99

1.413

0.01

1500

2.99

1.413

0.01

1500

2.99

1.413

0.01

1500

2.99

1.413

0.01

1.00

0.55

0.02

121.00

61

4.00

3.18

0.02

2.98

0.03

2.98

0.03

3.71

0.04

3.71

0.04

2.77

0.03

3.18

0.02

3.18
7.44

3.60

0.02
2.16

0.04

3.71

0.04

2.77

0.03

3.71

0.04

3.71

0.04

2.77
7.44
500

1.078 N/A

N/A

0.01

3.71

0.03

3.60

2.16

0.01

2.30

1.32

0.13

Resistencia de
secuencia cero

Reactancia de
secuencia
negativa

Resistencia de
secuencia
negativa

Reactancia
subtransitoria
saturada

Resistencia del
Estator

Cte. de Tpo.
transitoria de
Cortocircuito Eje
Directo

Cte. de tpo.
transitoria de
cortocircuito eje
en cuadratura

Ro

X2

R2

X"dsat

rstr

T'd

T'q

[p.u.]

[p.u.]

[p.u.]

[p.u.]

[p.u.]

[s]

0.138

0.01

0.49

0.13

0.138

0.01

0.49

0.19

0.112

0.03

0.28

0.19

0.112

0.03

0.28

0.19

0.112

0.03

0.28

0.19

0.112

0.03

0.28

0.17

0.1753

0.00

0.48

0.17

0.1753

0.00

0.48

0.17

0.1753

0.00

0.48

0.17

0.1753

0.00

0.48

0.17

0.1753

0.00

0.48

0.17

0.1753

0.00

0.48

0.17

0.1753

0.00

0.48

0.17

0.1753

0.00

0.48

0.17

0.1753

0.00

0.48

0.13

0.138

0.01

0.49

0.13

0.138

0.01

0.49

0.13

0.138

0.01

0.49

0.13

0.138

0.01

0.49

0.13

0.138

0.01

0.49

0.13

0.138

0.01

0.49

0.20

0.2158

0.00

2.03

121

0.00

0.00

0.20

0.00

0.14

0.21

0.01

0.19

0.21

0.01

0.19

0.20

0.00

0.16

0.20

0.00

0.16

0.22

0.00

0.19

0.20

0.00

0.14

0.20

0.00

0.14

0.00

100.00

0.20

0.00

0.16

0.20

0.00

0.16

0.22

0.00

0.19

0.20

0.00

0.16

0.20

0.00

0.16

0.22

0.00

0.19

0.126

0.00

100.00

0.187

0.30

4.18

12.00

0.15

0.126

0.15
0

[s]

0.13

0.20

Cte. de Tpo.
subtransitoria de
cortocircuito eje
directo

Cte. de Tpo.
subtransitoria
de
cortocircuito
eje en

Reactancia
Transitoria de
Eje Directo

Reactancia
Transitoria de
Eje en
Cuadratura

Reactancia
Subtransitoria
de Eje Directo

Reactancia
Subtransitoria
de Eje en
Cuadratura

Reactancia de
Saturacin de
Potier

T"d

T"q

X'd

X'q

X"d

X"q

Xp

[s]

[p.u.]

[p.u.]

[p.u.]

[s]

[p.u.]

[p.u.]

0.01

0.0056

0.21

0.14

0.125

0.01

0.0056

0.21

0.14

0.125

0.01

0.015

0.18

0.11

0.276

0.01

0.015

0.18

0.11

0.276

0.01

0.015

0.18

0.11

0.276

0.01

0.015

0.18

0.11

0.276

0.01

0.01

0.26

0.18

0.16

0.01

0.0057

0.26

0.18

0.1603

0.01

0.0057

0.26

0.18

0.1603

0.01

0.0057

0.26

0.18

0.1603

0.01

0.0057

0.26

0.18

0.1603

0.01

0.0057

0.26

0.18

0.1603

0.01

0.0057

0.26

0.18

0.1603

0.01

0.0057

0.26

0.18

0.1603

0.01

0.0057

0.26

0.18

0.1603

0.01

0.0056

0.21

0.14

0.125

0.01

0.0056

0.21

0.14

0.125

0.01

0.0056

0.21

0.14

0.125

0.01

0.0056

0.21

0.14

0.125

0.01

0.0056

0.21

0.14

0.125

0.01

0.0056

0.21

0.14

0.125

0.06

0.079

0.32

0.55

0.22

0.224

0.00

0.079

21.00

61

13.00

14

0.01

0.19

0.14

0.03

0.28

0.20

0.03

0.28

0.20

0.01

0.21

0.15

0.01

0.21

0.15

0.03

0.23

0.17

0.01

0.19

0.14

0.01

0.19

0.14

10.00

0.18

0.13

0.01

0.21

0.15

0.01

0.21

0.15

0.03

0.23

0.17

0.01

0.21

0.15

0.01

0.21

0.15

0.03

0.23

0.17

10.00

0.18

0.03

0.206

0.40

1.32

0.166

0.13

0.166

0.21

0.194

0.029

Impedancia de Neutro a Tierra


Punto de Conexin para efectos de
Sincronizacin (1)
Xe

Re

[Ohm]

[Ohm]
S/E Central Constitucin 2
S/E Central Constitucin 2
S/E Central Constitucin 2
S/E Central Constitucin 2
S/E Central Constitucin 2
S/E Central Constitucin 2
Central Chilo
Central Chilo
Central Chilo
Central Chilo
Central Chilo
Central Chilo
Central Chilo
Central Chilo
Central Chilo
S/E Central Constitucin 1
S/E Central Constitucin 1
S/E Central Constitucin 1
S/E Central Constitucin 1
S/E Central Constitucin 1
S/E Central Constitucin 1
S/E Florida
S/E Florida 12kV
S/E Concn
S/E Concn
S/E Concn
S/E El Totoral
S/E El Totoral
S/E El Totoral
S/E Las Vegas
S/E Las Vegas
S/E Linares Norte
S/E Placilla
S/E Placilla
S/E Placilla
S/E Quintay
S/E Quintay
S/E Quintay
S/E San Gregorio
380 S/E Mariposas 6.6kV

Punto de Conexin (2)

S/E Constitucin 23kV


S/E Constitucin 23kV
S/E Constitucin 23kV
S/E Constitucin 23kV
S/E Constitucin 23kV
S/E Constitucin 23kV
S/E Quelln 23kV
S/E Quelln 23kV
S/E Quelln 23kV
S/E Quelln 23kV
S/E Quelln 23kV
S/E Quelln 23kV
S/E Quelln 23kV
S/E Quelln 23kV
S/E Quelln 23kV
S/E Constitucin 23kV
S/E Constitucin 23kV
S/E Constitucin 23kV
S/E Constitucin 23kV
S/E Constitucin 23kV
S/E Constitucin 23kV
S/E Florida 12.5kV
S/E Florida 110kV
S/E Concn 12kV
S/E Concn 12kV
S/E Concn 12kV
S/E El Totoral 12.5kV
S/E El Totoral 12.5kV
S/E El Totoral 12.5kV
S/E Las Vegas 12kV
S/E Las Vegas 12kV
S/E Linares Norte 13.8kV
S/E Placilla 12kV
S/E Placilla 12kV
S/E Placilla 12kV
S/E Quintay 12kV
S/E Quintay 12kV
S/E Quintay 12kV
S/E San Gregorio 13.8kV
S/E Maule 66kV

UNIDADES GENERADORAS PMGD


Favor incluir la velocidad nominal de la unidad y revisar los valores de las inercias de las mquinas respecto

Cdigo Unidad

Propietario

Nombre Central

Unidad

C01U01G081

CAEMSA

Caemsa

C01U02G081

CAEMSA

Caemsa

C01U03G081

CAEMSA

Caemsa

C02U01G022

CARBOMET

Los Bajos

C01U01G023

CELMSA

Los Morros

C01U02G023

CELMSA

Los Morros

C01U03G023

CELMSA

Los Morros

C01U04G023

CELMSA

Los Morros

C01U05G023

CELMSA

Los Morros

C01U01G044

EL MANZANO

El Manzano

C04U01G035

ELEKTRA GENERACION

Monte Patria

C04U02G035

ELEKTRA GENERACION

Monte Patria

C04U03G035

ELEKTRA GENERACION

Monte Patria

C04U04G035

ELEKTRA GENERACION

Monte Patria

C04U05G035

ELEKTRA GENERACION

Monte Patria

C04U06G035

ELEKTRA GENERACION

Monte Patria

C04U07G035

ELEKTRA GENERACION

Monte Patria

C04U08G035

ELEKTRA GENERACION

Monte Patria

C03U01G035

ELEKTRA GENERACION

Punitaqui

C03U02G035

ELEKTRA GENERACION

Punitaqui

C03U03G035

ELEKTRA GENERACION

Punitaqui

C03U04G035

ELEKTRA GENERACION

Punitaqui

C03U05G035

ELEKTRA GENERACION

Punitaqui

C03U06G035

ELEKTRA GENERACION

Punitaqui

C01U01G007

GESAN

Sauce Andes

C01U02G007

GESAN

Sauce Andes

C01U03G007

GESAN

Sauce Andes

C01U04G007
C02U01G001

GESAN
HASA

Sauce Andes
Juncalito

C01U01G055

HIDROELEC S.A.

Truful Truful

C01U01G063

HIDROELECTRICA TRUENO

Trueno

C01U02G063

HIDROELECTRICA TRUENO

Trueno

Actualiza info

C01U01G060

HIDROPALOMA S.A.

La Paloma

Agrega info

C01U02G060

HIDROPALOMA S.A.

La Paloma

C01U01G045

NUTRECO

Skretting

C01U02G045

NUTRECO

Skretting

C01U01G064

ON-GROUP

El Trtaro

C01U01G056

ORAFTI

Orafti

C01U01G040

PUCLARO

Puclaro

C01U02G040

PUCLARO

Puclaro

C08U01G018

SAGESA

Los Sauces I

C08U02G018

SAGESA

Los Sauces I

C15U01G018

SAGESA

Los Sauces II

C15U02G018

SAGESA

Los Sauces II

C02U01G018

SAGESA

Caete

C02U02G018

SAGESA

Caete

C02U03G018

SAGESA

Caete

C03U01G018

SAGESA

Chufken (Traigun)

C03U02G018

SAGESA

Chufken (Traigun)

C03U03G018

SAGESA

Chufken (Traigun)

C03U04G018

SAGESA

Chufken (Traigun)

C04U01G018

SAGESA

Collipulli (Malleco)

C04U02G018

SAGESA

Collipulli (Malleco)

C04U03G018

SAGESA

Collipulli (Malleco)

C04U04G018

SAGESA

Collipulli (Malleco)

C06U01G018

SAGESA

Curacautin

C06U02G018

SAGESA

Curacautin

C06U03G018

SAGESA

Curacautin

C09U01G018

SAGESA

Quelln

C09U02G018

SAGESA

Quelln

C09U03G018

SAGESA

Quelln

C09U04G018

SAGESA

Quelln

C09U05G018

SAGESA

Quelln

C09U06G018

SAGESA

Quelln

C01U01G057

SGA

Biomar

C01U02G057

SGA

Biomar

C01U03G057

SGA

Biomar

C02U01G057

SGA

Eagon

C02U02G057

SGA

Eagon

C02U03G057

SGA

Eagon

C05U01G057

SGA

Louisiana Pacific

C05U02G057

SGA

Louisiana Pacific

C05U03G057

SGA

Louisiana Pacific

C05U04G057

SGA

Louisiana Pacific

C03U01G057

SGA

Multiexport 1

C04U01G057

SGA

Multiexport 2

C04U02G057

SGA

Multiexport 2

C06U01G057

SGA

Salmofood 1

C07U01G057

SGA

Salmofood 2

C07U02G057

SGA

Salmofood 2

C08U01G057

SGA

Watts 1

C09U01G057

SGA

Watts 2

C09U02G057

SGA

Watts 2

C10U01G057

SGA

Los Corrales

C12U01G018

SAGESA

Lonquimay

C12U02G018

SAGESA

Lonquimay

C13U01G018

SAGESA

Tira

C14U01G057

SGA

Southern Bulbs

C15U01G057

SGA

Lousiana Pacific Lautaro

C16U01G057

SGA

Polincay

C16U02G057

SGA

Polincay

C16U03G057

SGA

Polincay

C17U01G057

SGA

Skretting Osorno

C17U02G057

SGA

Skretting Osorno

C17U03G057

SGA

Skretting Osorno

C17U04G057

SGA

Skretting Osorno

C18U01G057

SGA

Skretting Pargua

C18U02G057

SGA

Skretting Pargua

C19U01G057

SGA

Danisco

C20U01G057

SGA

JCE

C04U01G031

TECNORED

Casa Blanca 1

C04U02G031

TECNORED

Casa Blanca 1

C11U01G031

TECNORED

Casa Blanca 2

C03U01G031

TECNORED

Curauma

C03U02G031

TECNORED

Curauma

C03U03G031

TECNORED

Curauma

C10U01G031

TECNORED

Tapihue

C10U02G031

TECNORED

Tapihue

C01U01G053

CRISTALERIAS TORO

Cristoro

C01U02G053

CRISTALERIAS TORO

Cristoro

C01U03G053

CRISTALERIAS TORO

Cristoro

C01U04G053

CRISTALERIAS TORO

Cristoro

C01U05G053

CRISTALERIAS TORO

Cristoro

No han sifo entragadas


C01U01G053al despacho
CRISTALERIAS TORO
No han sifo entragadas
C01U01G053al despacho
CRISTALERIAS TORO

Cristoro

Cristoro

C01U01G068

CGI-IANSA

Planta Curic

C01U01G069

GENERHOM

Pehui

C01U01G070

HIDROELECTRICA DONGO

Dongo

C01U01G072

GANADERA Y FORESTAL CARRAN

Doa Hilda

C01U01G080

DONGUIL ENERGA

DONGUIL

C01U01G083

HIDROELECTRICA MALLARAUCO

Mallarauco

Actualiza info

C01U01G084

HIDROELECTRICA DIUTO

El Diuto

Actualiza info

C01U01G085

HIDROELECTRICA MUCHI

Muchi

Actualiza info

C01U02G085

HIDROELECTRICA MUCHI

Muchi

Actualiza info

C01U01G086

LA ARENA SPA

La Arena

Actualiza info

C01U01G054

ENERBOSCH S.A

Reca

C02U01G054

ENERBOSCH S.A

Purisima

Actualiza info

C02U01G064

ON-GROUP

HBS

Actualiza info

C03U01G064

ON-GROUP

Tomaval

Agrega info

C01U01G090

HIDRONALCAS

Nalcas

Agrega info

C01U02G090

HIDRONALCAS

Nalcas

Agrega info

C01U01G091

HIDROCALLAO

Callao

Agrega info

C01U02G091

HIDROCALLAO

Callao

Nota:

res de las inercias de las mquinas respecto de las unidades de medidas sealadas en las columnas S, T, U y V.

Tipo de Unidades

Combustible

Tipo de
Turbina

Potencia Bruta

Consumos
Propios

Potencia Neta
Efectiva

Potencia Mnima
Tcnica

[MW]

[%]

[MW]

[MW]

Hidrulica Pasada

Francis

1.62

1.13%

1.60

Hidrulica Pasada

Francis

1.62

1.13%

1.60

Hidrulica Pasada

Francis

2.10

0.80%

1.93

Hidrulica Pasada

Francis

5.12

0.35%

5.10

Hidrulica Pasada

Francis

0.50

1.50%

0.49

0.10

Hidrulica Pasada

Francis

0.50

1.50%

0.49

0.10

Hidrulica Pasada

Francis

0.50

1.50%

0.49

0.10

Hidrulica Pasada

Kapln

0.84

1.50%

0.83

0.05

Hidrulica Pasada

Kapln

0.84

1.50%

0.83

0.05

Hidrulica

0.75

Trmica

Diesel

1.20

0.00%

1.20

0.13

Trmica

Diesel

1.20

0.00%

1.20

0.13

Trmica

Diesel

1.10

0.00%

1.10

0.13

Trmica

Diesel

1.10

0.00%

1.10

0.13

Trmica

Diesel

1.10

0.00%

1.10

0.13

Trmica

Diesel

1.10

0.00%

1.10

0.13

Trmica

Diesel

1.10

0.00%

1.10

0.13

Trmica

Diesel

1.10

0.00%

1.10

0.13

Trmica

Diesel

1.50

0.00%

1.50

0.17

Trmica

Diesel

1.50

0.00%

1.50

0.17

Trmica

Diesel

1.50

0.00%

1.50

0.17

Trmica

Diesel

1.50

0.00%

1.50

0.17

Trmica

Diesel

1.50

0.00%

1.50

0.17

Trmica

Diesel

1.50

0.00%

1.50

0.17

Hidrulica Pasada

Francis

0.24

1.14%

0.23

0.06

Hidrulica Pasada

Francis

0.24

1.14%

0.23

0.06

Hidrulica Pasada

Francis

0.34

1.14%

0.32

0.07

Hidrulica Pasada

Francis

0.36
1.47

1.14%

0.34

0.08

Hidrulica Pasada

Francis

0.41

0.04%

0.40

0.10

Hidrulica Pasada

Francis

2.84

0.10%

2.84

1.02

Hidrulica Pasada

Francis

2.84

0.10%

2.84

1.02

Hidrulica Pasada

Francis

2.25

0.05%

2.25

0.40

Hidrulica Pasada

Francis

2.25

0.05%

2.25

0.40

Trmica

diesel

0.75

0.00%

1.35

Trmica

diesel

0.75

0.00%

1.35

0.14
Hidrulica

Francis

2.60

0.10%

2.60

1.40

Hidrulica

Francis

2.60

0.10%

2.60

1.40

Trmica

diesel

0.80

0.00%

0.80

0.20

Trmica

diesel

0.80

0.00%

0.80

0.20

Trmica

diesel

0.80

0.00%

0.80

0.20

Trmica

diesel

0.80

0.00%

0.80

0.20

Trmica

diesel

0.83

0.00%

0.83

0.20

Trmica

diesel

0.83

0.00%

0.83

0.20

Trmica

diesel

1.40

0.00%

1.40

Trmica

diesel

0.85

0.00%

0.83

0.20

Trmica

diesel

0.85

0.00%

0.83

0.20

Trmica

diesel

0.80

0.00%

0.83

0.20

Trmica

diesel

0.80

0.00%

0.80

0.20

Trmica

diesel

0.83

0.00%

0.83

0.20

Trmica

diesel

0.83

0.00%

0.83

0.20

Trmica

diesel

0.83

0.00%

0.83

0.20

Trmica

diesel

0.83

0.00%

0.83

0.20

Trmica

diesel

0.80

0.00%

0.80

0.19

Trmica

diesel

1.40

0.00%

1.40

0.42

Trmica

diesel

0.85

0.00%

0.85

0.19

Grupo Electrgeno

Diesel

0.75

0.00%

0.87

0.26

Grupo Electrgeno

Diesel

0.75

0.00%

1.12

0.34

Grupo Electrgeno

Diesel

0.75

0.00%

0.85

0.26

Grupo Electrgeno

Diesel

0.75

0.00%

1.40

0.42

Grupo Electrgeno

Diesel

0.75

0.00%

1.40

0.42

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

0.42

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.73

0.00%

0.73

Grupo Electrgeno

Diesel

0.73

0.00%

0.73

Grupo Electrgeno

Diesel

0.73

0.00%

0.73

Grupo Electrgeno

Diesel

0.73

0.00%

0.73

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

1.60

0.00%

1.60

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

0.80

0.00%

0.80

Hidrulica Pasada
Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.80

0.00%

0.80

Grupo Electrgeno

Diesel

0.75

0.00%

0.75

Grupo Electrgeno

Diesel

0.75

0.00%

0.75

Grupo Electrgeno

Diesel

0.75

0.00%

0.75

Grupo Electrgeno

Diesel

0.75

0.00%

0.75

Grupo Electrgeno

Diesel

1.35

0.00%

1.35

Grupo Electrgeno

Diesel

1.35

0.00%

1.35

Grupo Electrgeno

Diesel

0.80

Grupo Electrgeno

Diesel

0.80

Trmica

Diesel

0.80

0.00%

0.80

0.24

Trmica

Diesel

0.80

0.00%

0.80

0.24

Trmica

Diesel

0.50

Trmica

Diesel

1.20

0.00%

1.20

0.36

Trmica

Diesel

0.75

0.00%

0.65

0.20

Trmica

Diesel

0.75

0.00%

0.65

0.20

Trmica

Gas Natural

3.20

0.00%

3.20

0.96

Trmica

Gas Natural

3.20

0.00%

3.20

0.96

Elica

Bonus, doble generador ambos


0.6/0.12
una jaula

1.00%

0.594/0.119

0.01

Elica

Bonus, doble generador ambos


0.6/0.12
una jaula

1.00%

0.594/0.119

0.01

Elica

He Wind, jaula simple

0.78

1.00%

0.77

Elica

He Wind, jaula simple

0.78

1.00%

0.77

Elica

He Wind, jaula simple

0.78

1.00%

0.77

Elica

He Wind, doble alimentacin asncrona


1.50
con rotor
1.00%
bobinado de anillos
1.49colectores

0.00

Elica

He Wind, doble alimentacin asncrona


1.50
con rotor
1.00%
bobinado de anillos
1.49colectores

0.00

Hidrulica Pasada

Francis

0.42

0.02%

0.40

0.00

Hidrulica Pasada

Kapln

0.25

4.00%

0.24

0.05

Hidrulica Pasada

Francis

3.40

0.10%

3.40

1.24

Hidrulica Pasada

3.30

Hidrulica Pasada

Francis

0.30

0.05%

0.30

0.10

Hidrulica Pasada

Francis

0.70

0.05%

0.70

0.20

Hidrulica Pasada

3.00

Hidrulica Pasada

1.70

Hidrulica Pasada
Trmica

Diesel

Trmica

Diesel

2.20
1.00

Hidrulica Pasada

Pelton

3.40

0.25%

3.39

0.15

Hidrulica Pasada

Pelton

3.40

0.25%

3.39

0.15

Hidrulica Pasada

Pelton

1.65

0.25%

1.65

0.10

Hidrulica Pasada

Pelton

1.65

0.25%

1.65

0.10

Tasa de
Indisponibilidad
Forzada

Tasa de
Indisponibilidad
Forzada en Hora
Punta (*)

Tasa de
Indisponibilida
d Programada

Tensin
Nominal

[hrs/ao]

[hrs/ao]

[hrs/ao]

[kV]

Factor de
Potencia
Nominal

Mtodo de
Conexin del
Neutro a Tierra

12

170

2.40

0.80 YN

12

170

2.40

0.80 YN

12

170

2.40

0.99 YN

18

180

12.60

0.85 YN

50

16

12.50

0.90

12.50

0.90

12.50

0.90

12.50

0.90

12.50

0.90

6.30

0.85 Y

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

23.00

0.80 YN

13.20

0.80 YN

13.20

0.80 YN

13.20

0.80 YN

13.20

0.80 YN

13.20

0.80 YN

13.20

0.80 YN

2715

0.50

0.80

3690

0.50

0.80

2682

0.50

0.80

1434

0.50

0.80

23.00

0.80 YN

0.69

0.90 YN

0.69

0.90 YN

6.30

0.80 YN

6.30

0.80 YN

3.30

0.80 YN

3.30

0.80 YN

175.2

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

75

100

0.40

1.00 Directo

0.40

0.80

0.40

0.80

0.40

0.80

0.40

0.80

0.40

0.80

0.40

0.80

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

12.00

0.80

0.69

0.97/0.95

0.69

0.97/0.96

0.69

0.94

0.69

0.94

0.69

0.94

0.69

1.00

0.69

1.00

3.60

0.80

12.50

0.90

3.30

0.90 YN

0.40

0.8

0.40

0.8

6.30

0.8

YN

6.30

0.8

YN

6.30

0.8

YN

6.30

0.8

YN

Velocidad
Nominal

[RMP]

Constante de
Inercia

Factor

Factor

Reactancia
sincrnica de
eje directo

Reactancia
sincrnica de
eje en
cuadratura

Reactancia de
secuencia cero

GD2

WR2

Xd

Xq

Xo

[s]

[kg m2]

[lb ft2]

[p.u.]

[p.u.]

[p.u.]

1.43

0.07

1.43

0.07

1.26

0.07

1.03

0.12

1.15

0.579

1500

2.96

1.91

0.02

1500

2.96

1.91

0.02

1500

3.26

2.1

0.03

1500

3.26

2.1

0.03

1500

3.26

2.1

0.03

1500

3.26

2.1

0.03

1500

3.26

2.1

0.03

1500

3.26

2.1

0.03

1500

2.99

1.413

0.01

1500

2.99

1.413

0.01

1500

2.99

1.413

0.01

1500

2.99

1.413

0.01

1500

2.99

1.413

0.01

1500

2.99

1.413

0.01

2.10

0.07

2.10

0.07

2.10

0.07

2.10

0.07

1000

0.499

1.03

0.12

750

0.483

1.67

0.835

0.05

750

0.483

1.67

0.835

0.05

500

1.28

0.77

0.12

500

1.28

0.77

0.12

600

0.598

1.30

0.65

0.05

600

0.598

1.30

0.65

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

2.45

1.1718

0.05

1.84

0.9144

0.05

1.84

0.9144

0.05

2.39

1.1132

0.04

1.84

0.9144

0.05

2.45

1.1718

0.05

2.45

1.1718

0.05

2.45

1.1718

0.05

1000

0.03

2.98

0.03

3.18

0.02

2.98

0.03

2.98

0.03

0.84

0.443

0.03

1.49

0.745

0.05

750

1.70

1.54

0.006

1000

1.80

1.62

0.016

750

2.98

0.43

500

0.81

N/A

N/A

1.77

1.59

0.004

500

0.81

N/A

N/A

1.77

1.59

0.004

600

0.58

N/A

N/A

1.30

0.77

0.007

600

0.58

N/A

N/A

1.30

0.77

0.007

Resistencia de
secuencia cero

Reactancia de
secuencia
negativa

Resistencia de
secuencia
negativa

Reactancia
subtransitoria
saturada

Resistencia del
Estator

Cte. de Tpo.
transitoria de
Cortocircuito Eje
Directo

Cte. de tpo.
transitoria de
cortocircuito eje
en cuadratura

Ro

X2

R2

X"dsat

rstr

T'd

T'q

[p.u.]

[p.u.]

[p.u.]

[p.u.]

[p.u.]

[s]

[s]

0.16

0.00

8.30

0.16

0.00

8.30

0.16

0.00

8.30

0.41

0.00

8.30

0.19

0.13

0.01

0.14

0.19

0.13

0.01

0.14

0.21

0.15

0.01

0.13

0.21

0.15

0.01

0.13

0.21

0.15

0.01

0.13

0.21

0.15

0.01

0.13

0.21

0.15

0.01

0.13

0.21

0.15

0.01

0.13

0.13

0.138

0.01

0.49

0.13

0.138

0.01

0.49

0.13

0.138

0.01

0.49

0.13

0.138

0.01

0.49

0.13

0.138

0.01

0.49

0.13

0.138

0.01

0.49

0.13

0.12

0.02

0.40

0.13

0.12

0.02

0.40

0.13

0.12

0.02

0.40

0.13

0.12

0.02

0.40

0.14

0.12

0.01

0.47

0.18

0.01376

0.158

0.01

0.48

0.4

0.18

0.01376

0.158

0.01

0.48

0.4

0.19

0.144

0.25

0.19

0.144

0.25

0.19

0.01

0.16

0.01

0.42

0.4

0.19

0.01

0.16

0.01

0.42

0.4

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.17

0.01

0.11

0.02

0.17
0

0.17

0.01
0

0.01

0.16

0.01

0.17

0.01

0.11

0.02

0.11

0.02

0.11

0.02

0.21

0.01

0.19

0.21

0.01

0.19

0.20

0.00

0.14

0.21

0.01

0.19

0.21

0.01

0.19

0.00618/0.0134
0.00618/0.0134
0.02
0.02
0.02

0.25
0.18

0.00682

0.175

0.01

0.52

0.4

0.184

0.127

0.109

0.94

0.233

0.16

0.167

1.41

0.00

0.271

0.00

0.161

0.369

3.04

0.00

0.271

0.00

0.161

0.369

3.04

0.00

0.185

0.00

0.16

0.43

0.40

0.00

0.185

0.00

0.16

0.43

0.40

Cte. de Tpo.
subtransitoria de
cortocircuito eje
directo

Cte. de Tpo.
subtransitoria
de
cortocircuito
eje en

Reactancia
Transitoria de
Eje Directo

Reactancia
Transitoria de
Eje en
Cuadratura

Reactancia
Subtransitoria
de Eje Directo

Reactancia
Subtransitoria
de Eje en
Cuadratura

Reactancia de
Saturacin de
Potier

T"d

T"q

X'd

X'q

X"d

X"q

Xp

[s]

[s]

[p.u.]

[p.u.]

[p.u.]

[p.u.]

[p.u.]

0.06

0.06

0.26

0.15

0.06

0.06

0.26

0.15

0.06

0.06

0.38

0.18

0.06

0.06

0.28

0.28

0.26

0.579

0.17

0.202

0.01

0.18

0.13

0.27

0.01

0.18

0.13

0.27

0.01

0.20

0.15

0.29

0.01

0.20

0.15

0.29

0.01

0.20

0.15

0.29

0.01

0.20

0.15

0.29

0.01

0.20

0.15

0.29

0.01

0.20

0.15

0.29

0.01

0.0056

0.21

0.14

0.125

0.01

0.0056

0.21

0.14

0.125

0.01

0.0056

0.21

0.14

0.125

0.01

0.0056

0.21

0.14

0.125

0.01

0.0056

0.21

0.14

0.125

0.01

0.0056

0.21

0.14

0.125

0.01

0.08

0.13

0.01

0.08

0.13

0.01

0.08

0.13

0.01

0.08

0.13

0.01

0.05

0.09

0.19

0.18

0.02

0.04

0.28

0.835

0.17

0.174

0.02

0.04

0.28

0.835

0.17

0.174

0.02

0.27

0.77

0.17

0.211

0.02

0.27

0.77

0.17

0.211

0.224

0.03

0.04

0.23

0.65

0.15

0.03

0.04

0.23

0.65

0.15

0.224

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.46

0.11

0.2345

0.61

0.10

0.1106

0.46

0.11

0.2345

0.46

0.11

0.2345

0.60

0.15

0.173

0.46

0.11

0.2345

0.61

0.10

0.1106

0.61

0.10

0.1106

0.61

0.10

0.1106

0.03

0.28

0.20

0.03

0.28

0.20

0.01

0.19

0.14

0.03

0.28

0.20

0.00

0.28

0.20

0.14

0.443

0.14

0.443

0.02

0.04

0.28

0.745

0.16

0.175

0.01

0.00

0.20

1.54

0.127

0.266

0.04

0.01

0.21

1.62

0.160

0.34

0.08

0.03

0.22

1.59

0.161

0.457

0.08

0.03

0.22

1.59

0.161

0.457

0.04

0.04

0.23

0.65

0.176

0.224

0.04

0.04

0.23

0.65

0.176

0.224

Impedancia de Neutro a Tierra


Punto de Conexin para efectos de
Sincronizacin (1)
Xe

Re

[Ohm]

[Ohm]

2.0832

0 S/E Caemsa 12kV

2.0832

0 S/E Caemsa 12kV

0.9987

0 S/E Caemsa 12kV

0.053

0 S/E Los Bajos 12.6 kV


S/E Los Morros
S/E Los Morros
S/E Los Morros
S/E Los Morros
S/E Los Morros
S/E Licanco
S/E Central Monte Patria
S/E Central Monte Patria
S/E Central Monte Patria
S/E Central Monte Patria
S/E Central Monte Patria
S/E Central Monte Patria
S/E Central Monte Patria
S/E Central Monte Patria
S/E Central Punitaqui
S/E Central Punitaqui
S/E Central Punitaqui
S/E Central Punitaqui
S/E Central Punitaqui
S/E Central Punitaqui
S/E Sauce Andes
S/E Sauce Andes
S/E Sauce Andes
S/E Sauce Andes

0.89

0 S/E Truful Truful 23 kV

0 S/E Lautaro 13,2 kV

0 S/E Lautaro 13,2 KV


S/E Monte Patria 13,2kV
S/E Monte Patria 13,2kV
S/E Colaco
S/E Colaco

0 S/E Marquesa 23kV

0 S/E Marquesa 23kV


S/E Angol
S/E Angol
S/E Traiguen 66 KV

S/E Traiguen 66 KV
S/E Tres Pinos 23kV
S/E Tres Pinos 23kV
S/E Tres Pinos 23kV
S/E Traiguen 13.2KV
S/E Traiguen 13.2KV
S/E Traiguen 13.2KV
S/E Traiguen 13.2KV
S/E Collipulli 13.2
S/E Collipulli 13.2
S/E Collipulli 13.2
S/E Collipulli 13.2
S/E Curacautin 13.2kV
S/E Curacautin 13.2kV
S/E Curacautin 13.2kV
S/E Quelln 23KV
S/E Quelln 23KV
S/E Quelln 23KV
S/E Quelln 23KV
S/E Quelln 23KV
S/E Quelln 23KV
S/E Pargua 23KV
S/E Pargua 23KV
S/E Pargua 23KV
S/E Lautaro 13.2KV
S/E Lautaro 13.2KV
S/E Lautaro 13.2KV
S/E Panguipulli 23KV
S/E Panguipulli 23KV
S/E Panguipulli 23KV
S/E Panguipulli 23KV
S/E Melipulli 23KV
S/E Melipulli 23KV
S/E Melipulli 23KV
S/E Pid Pid 23KV
S/E Pid Pid 23KV
S/E Pid Pid 23KV
S/E Osorno 23KV
S/E Osorno 23KV
S/E Osorno 23KV
S/E Curacautn 13.2KV
S/E Curacautn 13.2KV
S/E Tres Pinos 13.2KV

S/E La Unin 23KV


S/E La Unin 23KV
S/E La Unin 23KV
S/E Osorno 23KV
S/E Osorno 23KV
S/E Osorno 23KV
S/E Osorno 23KV
S/E Colaco 23KV
S/E Colaco 23KV
S/E Colaco 23KV

S/E Los Angeles


S/E Casablanca
S/E Casablanca
S/E Curauma
S/E Curauma
S/E Curauma

S/E Lebu 66 kV
S/E Lebu 66 kV
S/E Lebu 66 kV
S/E Lebu 66 kV
S/E Lebu 66 kV
S/E Lebu 66 kV
S/E Lebu 66 kV

S/E Pichirropulli 23 kV
S/E Pitrufquen
0

0 S/E El Paico 13.2 kV


S/E Pichiropulli 23kV
S/E Pichiropulli 23kV

S/E Bonito 23kV


S/E Bonito 23kV
S/E Bonito 23kV
S/E Bonito 23kV

Punto de Conexin (2)

PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
S/E Monte Patria 23kV
S/E Monte Patria 23kV
S/E Monte Patria 23kV
S/E Monte Patria 23kV
S/E Monte Patria 23kV
S/E Monte Patria 23kV
S/E Monte Patria 23kV
S/E Monte Patria 23kV
S/E Punitaqui 13.2kV
S/E Punitaqui 13.2kV
S/E Punitaqui 13.2kV
S/E Punitaqui 13.2kV
S/E Punitaqui 13.2kV
S/E Punitaqui 13.2kV
PMGD
PMGD
PMGD
PMGD
Red MT Frontel
PMGD
PMGD
Red MT ENELSA
Red MT ENELSA
PMGD
PMGD

PMGD
PMGD
PMGD
PMGD
PMGD

PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD
PMGD

PMGD
PMGD
PMGD
PMGD
PMGD
PMGD

PMGD, Alimentador Lautaro 13.8kV (FRONTEL)


PMGD, Alimentador Lautaro 13.8kV (FRONTEL)
PMGD, Alimentador Lautaro 13.8kV (FRONTEL)
PMGD, Alimentador Lautaro 13.8kV (FRONTEL)
PMGD, Alimentador Lautaro 13.8kV (FRONTEL)
PMGD, Alimentador Lautaro 13.8kV (FRONTEL)
PMGD, Alimentador Lautaro 13.8kV (FRONTEL)

PMGD, Alimentador Futrono


PMGD
PMGD
PMGD
PMGD

S/E Bonito 66kV


S/E Bonito 66kV
S/E Bonito 66kV
S/E Bonito 66kV