CONTENT

1. ACKNOWLEDGEMENT 2. INTRODUCTION ABOUT PNB BUILDING 3. FIRE PROTECTION:


1) PRESSURISATION FAN 2) EXITSIGN 3) EMERGENCY LIGHT 4) FIREMAN SWITCH 5) SMOKE ALARM SYSTEM 6) FIRE EXTINGUISHER 7) MAIN FIRE ALARM PANEL :
7.1 MIMIC DIAGRAM

7.2 FIREMAN INTERCOM PANEL & HANDSET 7.3 COMPUTERRISED MONITORING SYSTEM(CMS)

8)PIPE RISER :
8.1 Domestic & Drinking Water Pipe

9) PUBLIC ADDRESS :
9.2 Public Address(P.A) Riser 9.2 Cable & Tray

10)

Acknowledgement

INTRODUCTION

PERMODALAN NASIONAL BERHAD BUILDING

FIRE PROTECTION

FIRE PROTECTION
PROPERTY DIVISION
FACILITIES MANAGEMENT DEPARTMENT

PNB

Sprinkler & Wet Riser Pump & Water Tank Room 27th Floor (Tower) Canvas Hose & Nozzle Basement 1 39th (Tower) Sprinkler & Wet Riser Pump Room 10th Floor (Tower) and Water Tank Room 11th, 13th & 14th Floor (Tower) Sprinkler & Wet Riser Pump & Water Tank Room Basement 2

PNB

PROPERTY DIVISION
FACILITIES MANAGEMENT DEPARTMENT

Hose Reel Pump & Water Tank Room 40th Floor (Tower)

Other System & Equipment at All Floor

Rubber Hose & Nozzle Basement 1 39th Floor (Tower) Basement 1 4th (Podium)

Rubber Hose & Nozzle Basement 1 39th Floor (Tower)

Co2 System at M & E Room 22 nd Floor (Tower)

Hose Reel Pump & Water Tank Room 5th Floor (Podium) Co2 System at M & E Room Basement 1

Building Automation System Room (B.A.S) UG Floor (Tower)

In this building compartmentalization is the fundamental basis and aim of passive for protection. The idea is to subdivide a structure into fire compartments, which may contain single or multiple rooms for the purpose of limiting the spread of fire, smoke and flue gases is order to enable the three goals of fire protection. 1. life safety 2. property protection 3. continuity of operations The construction of such compartment and all its components is a mother of systems within systems, which use listing and approval use and compliance to achieve fire resistance ratings, all interdependent, forming part of an overall fire safety plan. All components forming part of such a compartments are subject to stringent listing and approval use and compliance in countries where product certification is mandatory.

Pressurisation Fan

Pressurisation Fan

EXIT SIGN
Exit sign is the sign that is put over the emergency exit door. Its function is to notice people where the emergency exit way located. The design of the sign must to follow its standardization and to be approved by fire department. The standardization as the following: 1. The word exit must be in white colour while the background in green colour. 2. The width must be 22.5 cm while the length must be 40 cm.

EMERGENCY LIGHT

EMERGENCY LIGHT

FIREMAN SWITCH

FIREMAN SWITCH

Smoke Alarm System


Every building must have a smoke alarm. There are two types of smoke alarms that ionization alarms and optical alarms. However for this building,the optical alarms types of smoke alarms that are from models of alarms with 10 years battery as specified below. There are different types of models available that is: 1. Alarm with 10 years battery These are slightly more expensive but will save on the cost of replacing batteries. They are available as ionization or optical alarms and are fitter with a long life lithium battery or a sealed power pack that lasts for 10 years. 2. Standard battery alarms An ionization battery alarm is the cheapest and most basic smoke alarm available. An optical battery alarm is a little more expensive. Both run off 9 volt batteries which need to be test every week and replace once a year or when it beeps regularly, whichever is sooner. 3. Hush or silence button These models are available with a hush button and when pressed silences the alarm for a short time. For example, this functionally may be used when cooking. If there is a real fire, giving off lots of smoke, the hush system is overridden and the warning alarm sounds. 4. Main-powered Alarm These alarm are powered by the hotel electricity supply and needed to be installed by qualified electricians. 5. Battery Alarm with Emergency light If the alarm goes off the emergency light alerts people with hearing difficulties. 6. Main-Powered Alarm with Strobbed Light and Vibrating Pad These alarm are designed for people who are deaf or have hearing difficulties. If there are fire, you will be alerted instantly by the smoke alarm flashing light or vibrating pad under the bed. 7. Mains-Powered Alarm which Plugs into a Light Socket This alarm is rechargeable battery which charges up when the light is switched on. It lasts for 10 years and can be silenced or tested by the light switch.

ADVANTAGES:
1. Alert the danger of fire. 2. Give precious time for people to escape.

3. They are commonly available.

DISADVANTAGES:
1. The cost are expensive especially for ionization type of detectors. 2. Needed to be maintained to make sure the Alarm is still working. 3. The alarm could be in the wrong place. 4. There might be not enough smoke alarms for the large space area .

Smoke Alarm System

Fire Extinguisher

9 kg ABC at Office Area, Staircase, Basement

2.2 kg Carbon Dioxide at M & E Room

Fire Extinguisher
PNB building use 9kg ABC fire extinguisher at Office Area,Staircase and also at Basement.But at M & E Room use 2.2 kg Carbon Dioxide.Fire extinguishers are used to stop the burning material that start

from the first stage. People in this building need to learn the way of how fire extinguisher is used so that they can get ready whenever there are fire arises. Below the way of how to use the fire extinguisher: 1) 2) 3) 4) pull the safety pin aim the nozzle or hose at the base of fire squeeze the leaver to release the agent Sweep the agent from side to side at the base of the fire.

Advantages
1. 2. 3. 4. very easy to use can be used immediately in case of emergency portable Helps to reduce fire at the stage from spreading to other area of material

Disadvantages
1. limited usage 2. must be compatible with the type of fire 3. proper maintenance is essential

MAIN FIRE ALARM PANEL

Main Fire Alarm Panel

Main Fire Alarm Panel

Mimic Diagram

Mimic Diagram

Fireman Intercom Panel

Fire Intercom Handset

Fireman Intercom Panel & Handset

Computerised monitoring system (CMS)

Pipe riser

Pipe Riser

Domestic & Drinking Water Pipe

Domestic Water Pipe

Drinking Water Pipe

Domestic & Drinking Water Pipe

PUBLIC ADDRESS

Public Address(P.A) Riser -

Cable & Tray -

HOSE REEL

RUBBER HOSE

RUBBER HOSE

The pipes conveying water to hose reels must comply with the requirements of the Water Byelaws for pipes carrying cold water for ordinary domestic use. In particular steel or iron pipe will not be permitted unless it is lined internally with an approved material.

Use of Hose Reels


The Fire Service would much prefer that hose reels should be used as much as possible for ordinary purposes such as washing vehicles, floors, etc. The people working in the building will then be familiar with their use and will notice if they are not in working order. (A notice should be fixed on each hose reel asking that any defects should be reported and saying to whom). The Water Authority have no objection to the hose reels being used in this way provided that the hose reels are paid for at the usual charge for a hose pipe or are metered. Provided the meters are of the correct size there is no objection to the supply to hose reels being metered.

CANVAS HOSE

SPRINKLER & WET RISER

Sprinkler System
Sprinkler
Sprinkler system are widely used in a building. It is installed at the ceiling and when the heat arise the sprinkler will activate by spraying water. It helps to stop the fire from spreading. For this hotel, we proposed Grinnel-type quatzoid sprinkler. This sprinkler will be installed to every room of the hotel to reduce the risk of dying. Sprinkler system it must be in conjunction with alongside a smoke alarm. The smoke alarm will alert you to slow-burning, smokegenerating fires which may not generate enough heat to trigger the sprinkler.

ADVANTAGES
1. Can be fitted as many rooms as you want them to be. 2. They are individually heat-activated, so the whole system doesnt go off at once. 3. They operate automatically, whether you are at home or not. 4. Suitable for older people and people who have difficulty moving around.

DISADVANTAGES
1. It makes the electrical material to be damaged. 2. The water can conduct electricity back to you. 3. High cost is needed 4. Can be used only once.

Duty, Standby & Jockey Pump

Pump Panel Duty, Standby & Jockey Pump -

Pump Panel -

Valve

Water Tank

Valve -

Water Tank -

Pressure Gauge

Sprinkler Head

Pressure Gauge -

Sprinkler Head -

Wet Riser System

Duty, Standbay & Jockey Pump

Pump Panel

Duty, Standbay & Jockey Pump -

Pump Panel -

Valve

Pressure Gauge Valve

Pressure Gauge

Layout Plan Of Fire Protection & Electrical

CONCLUSION