Documentos de Académico
Documentos de Profesional
Documentos de Cultura
7.2 FIREMAN INTERCOM PANEL & HANDSET 7.3 COMPUTERRISED MONITORING SYSTEM(CMS)
8)PIPE RISER :
8.1 Domestic & Drinking Water Pipe
9) PUBLIC ADDRESS :
9.2 Public Address(P.A) Riser 9.2 Cable & Tray
10)
Acknowledgement
INTRODUCTION
FIRE PROTECTION
FIRE PROTECTION
PROPERTY DIVISION
FACILITIES MANAGEMENT DEPARTMENT
PNB
Sprinkler & Wet Riser Pump & Water Tank Room 27th Floor (Tower) Canvas Hose & Nozzle Basement 1 39th (Tower) Sprinkler & Wet Riser Pump Room 10th Floor (Tower) and Water Tank Room 11th, 13th & 14th Floor (Tower) Sprinkler & Wet Riser Pump & Water Tank Room Basement 2
PNB
PROPERTY DIVISION
FACILITIES MANAGEMENT DEPARTMENT
Hose Reel Pump & Water Tank Room 40th Floor (Tower)
Rubber Hose & Nozzle Basement 1 39th Floor (Tower) Basement 1 4th (Podium)
Hose Reel Pump & Water Tank Room 5th Floor (Podium) Co2 System at M & E Room Basement 1
In this building compartmentalization is the fundamental basis and aim of passive for protection. The idea is to subdivide a structure into fire compartments, which may contain single or multiple rooms for the purpose of limiting the spread of fire, smoke and flue gases is order to enable the three goals of fire protection. 1. life safety 2. property protection 3. continuity of operations The construction of such compartment and all its components is a mother of systems within systems, which use listing and approval use and compliance to achieve fire resistance ratings, all interdependent, forming part of an overall fire safety plan. All components forming part of such a compartments are subject to stringent listing and approval use and compliance in countries where product certification is mandatory.
Pressurisation Fan
Pressurisation Fan
EXIT SIGN
Exit sign is the sign that is put over the emergency exit door. Its function is to notice people where the emergency exit way located. The design of the sign must to follow its standardization and to be approved by fire department. The standardization as the following: 1. The word exit must be in white colour while the background in green colour. 2. The width must be 22.5 cm while the length must be 40 cm.
EMERGENCY LIGHT
EMERGENCY LIGHT
FIREMAN SWITCH
FIREMAN SWITCH
ADVANTAGES:
1. Alert the danger of fire. 2. Give precious time for people to escape.
DISADVANTAGES:
1. The cost are expensive especially for ionization type of detectors. 2. Needed to be maintained to make sure the Alarm is still working. 3. The alarm could be in the wrong place. 4. There might be not enough smoke alarms for the large space area .
Fire Extinguisher
Fire Extinguisher
PNB building use 9kg ABC fire extinguisher at Office Area,Staircase and also at Basement.But at M & E Room use 2.2 kg Carbon Dioxide.Fire extinguishers are used to stop the burning material that start
from the first stage. People in this building need to learn the way of how fire extinguisher is used so that they can get ready whenever there are fire arises. Below the way of how to use the fire extinguisher: 1) 2) 3) 4) pull the safety pin aim the nozzle or hose at the base of fire squeeze the leaver to release the agent Sweep the agent from side to side at the base of the fire.
Advantages
1. 2. 3. 4. very easy to use can be used immediately in case of emergency portable Helps to reduce fire at the stage from spreading to other area of material
Disadvantages
1. limited usage 2. must be compatible with the type of fire 3. proper maintenance is essential
Mimic Diagram
Mimic Diagram
Pipe riser
Pipe Riser
PUBLIC ADDRESS
HOSE REEL
RUBBER HOSE
RUBBER HOSE
The pipes conveying water to hose reels must comply with the requirements of the Water Byelaws for pipes carrying cold water for ordinary domestic use. In particular steel or iron pipe will not be permitted unless it is lined internally with an approved material.
CANVAS HOSE
Sprinkler System
Sprinkler
Sprinkler system are widely used in a building. It is installed at the ceiling and when the heat arise the sprinkler will activate by spraying water. It helps to stop the fire from spreading. For this hotel, we proposed Grinnel-type quatzoid sprinkler. This sprinkler will be installed to every room of the hotel to reduce the risk of dying. Sprinkler system it must be in conjunction with alongside a smoke alarm. The smoke alarm will alert you to slow-burning, smokegenerating fires which may not generate enough heat to trigger the sprinkler.
ADVANTAGES
1. Can be fitted as many rooms as you want them to be. 2. They are individually heat-activated, so the whole system doesnt go off at once. 3. They operate automatically, whether you are at home or not. 4. Suitable for older people and people who have difficulty moving around.
DISADVANTAGES
1. It makes the electrical material to be damaged. 2. The water can conduct electricity back to you. 3. High cost is needed 4. Can be used only once.
Pump Panel -
Valve
Water Tank
Valve -
Water Tank -
Pressure Gauge
Sprinkler Head
Pressure Gauge -
Sprinkler Head -
Pump Panel
Pump Panel -
Valve
Pressure Gauge
CONCLUSION