170 300 kV Gas-insulated Substations The increasing demand for electrical power in cities and industrial centres necessitates the installation of a compact and efcient distribution and transmission network. High voltage gas-insulated switchgear (GIS) is ideal for such applications.
The B105 is single-phase, SF6 gas-insulated, high voltage metal-enclosed switchgear, which is continuously being upgraded to the state of the art. ALSTOMhasbeenactivelyinvolvedinSF6 technologyforseveraldecadesandourGIS havebeeninoperationworldwidesince 1965 withprovensuccess.Excellenteld experienceconrmsthesoundnessofour technicalconcepts.
Customer benets Minimum oor space requirements Insulated system unaffected by environmental conditions Modular design Almost unlimited extension and modication possibilities High operational reliability Simple maintenance Long service life expectancy
GRID
GAS-INSULATED SUBSTATIONS
B105
8 3
4 5 1 6
GAS-INSULATED SUBSTATIONS
B105
GIS components
Accessible circuit breakers
Thedevelopmentofthebreakingelement designisbasedonthefollowingfundamentalprinciples: Incorporationoftheexcellentoperating reliabilityoftheexistingdesign,proven overmanyyearsinservice. Leveragethelatestadvancesinplasma physics. Circuitbreakerperformancemeetingall latestIECandANSIstandards.
Reliable disconnectors
Thecontactelementisinstalledinadisconnectorenclosure.Thethreedisconnector polesaremechanicallycoupledtoeachother viaanoperatinglinkageandactuatedby acommonmotordrive.Theycanswitch capacitivecurrentsencounteredinthecourse ofenergisingorde-energisingportionsof theGISandloopcurrentswhencommuting currentsfromonebusbartoanother. Clearandsafeindicationofthemaincontacts positionisprovidedbyareliableindicator directlyttedtothelinkage.Thisindi catoris clearlyvisiblefromtheoperatinglevel.
GAS-INSULATED SUBSTATIONS
B105
Standard terminations
Cables,overheadlinesandtransformers canallbeconnectedtotheirrespective GISinterfacecomponents.Theseinclude outdoorSF6 toairbushings,cableterminationsanddirecttransformerconnections. AllcomponentscomplywithIECrecommendations.
Interconnecting components
ThevariouscomponentsoftheGISare assembledbymeansofstandardisedbolted anges.Interconnectingcomponentsare comprisedofaluminiumenclosureswith insulator-supportedconductors. Telescopiccouplingelements(inbusbars forexample)areusedtoconnectadjacent switchgearsections. Expansionelementswithmetalbellows areusedtocompensateforthermalexpansion/contractioncyclesandpositional tolerancesinbothlateralandlongitudinal directions.
GAS-INSULATED SUBSTATIONS
B105
Minimal maintenance
TheB105near-zeromaintenanceconcept delivershighreliabilityandavailabilitywith onlyoccasionalinspectionsandaguaranteedlonglifeexpectancyforallmechanical andelectricalparts. TheALSTOMserviceteamremainsatthe customersdisposalforanyassistanceand service. Aninspectionandmaintenanceplancan alsobeestablishedtosupporttheequipmentthroughoutitsentirelifecycle.
GAS-INSULATED SUBSTATIONS
B105
Layout
Double busbar
D2 D2
D3 D3
D4 D4
D5 D5
D6 D6
D7 D7
D1 D1
D2 D2
D3 D3
D4 D4
D5 D5
D6 D6
D7 D7
GAS-INSULATED SUBSTATIONS
B105
2200 2200
3700 3700
800 800
1600 1600
3800 3800
2200 2200
D5 Transformer bay with outgoing feeder
1600 1600
5000 5000
1000 1000
D4 Coupler bay
800 800
1600 1600
3800 3800
800 800
1600 1600
5000 5000
1000 1000 7
GAS-INSULATED SUBSTATIONS
B105
Technical data
General Rated voltage Rated frequency Rated lightning impulse withstand voltage, phase-ground Rated lightning impulse withstand voltage across disconnector contacts Rated power frequency withstand voltage, phase-ground Rated power frequency withstand voltage across disconnector contacts Rated current Rated peak withstand current Rated short-time current Min. gas operating pressure Switchgear Circuit breaker (gauge at 20 C) Auxiliary voltage Enclosure Installation Permissible ambient temperature Bay dimensions (W x D x H) Bay weight approx. Circuit-breaker Rated short-circuit breaking current Rated short-circuit making current Break time Closing time Type of operating mechanism Power consumption of operating mechanism (spring winding) Rated operating sequence Power consumption of trip or closing coil, approx. Earthing switch Rated short-circuit making current Power consumption of operating mechanism (spring winding) approx. Disconnector and maintenance earthing switch Power consumption of motor drive, approx. Other values on request kV Hz kV kV kV kV A kA kA bar bar V up to 300 up to 60 up to 1050 1256 up to 460 605 up to 4000 up to 170 up to 63 5.5 5.5 110/220 DC or AC single-phase indoor/outdoor 25/+55 1.5/1.85 x 5.0 x 3.7/4.2 5800/6400 up to 63 up to 170 50 115 single-pole, spring-operated 3 x 800 O 0.3 s CO 3 min CO/CO 15 s CO 3 x 350 up to 170 150 150
Grid-Products-L3-B105_Range-70613-2010_12 - EN Copyrights Alstom 2010, the Alstom logo and any alternative version thereof are trademarks and service marks of Alstom. The other names mentioned, registered or not, are the property of their respective companies. The technical and other data contained in this document are provided for Information only. Neither Alstom, its ofcers nor employees accept responsibility for or should be taken as making any representation or warranty (whether express or implied) as to the accuracy or compIeteness of such data or the achievements of any projected performance criteria where these are indicated. No liability is accepted for any reliance placed upon the information contained in this brochure. AIstom reserves the right to revise or change these data at any time without further notice. Printed of paper made with pure ECF (Elemental Chlorine Free) ecological cellulose produced from trees grown in production forests under responsible management, and selected recycled three-layer bres.