Está en la página 1de 3

Basic command for 2G BTS 1.

For UP/DOWN StatusRLCRP: CELL=ALL;( if shows 0 for all value site/sector will be down) 2. If site down check the condition of PCM if it is ABL (not working) verify theloop test to identify the fault and if PCM is working check the alarm on BTS. 3. For finding the PCM use commandRXTCP: MOTY=RXOTG, CELL=cell; (cell id with sector i.eBST001A)It gives TG VAULE RXAPP: MO=RXOTG-tg $; (tg$ is TG VALUE)It gives device no. use last device RADEP: DEV=dev$; (dev$ is device value i.eRBLT-2719)It gives SNT value NTCOP: SNT=snt$; Find the device no that is used in dev$ and corresponding vaule of DIP 4. Check the status of PCM DTSTP: DIP=dip$; (dip$ is DIP VALUE i.e 83RBLT) DTQDP: DIP=dip$; & DTQUP: DIP=dip$; (FOR finding error on PCM,Check the value of es, ses uas & SLIP ,these value must be 0 or constant) 5. If PCM condition found working then BLOCK /DEBLOCK to get managed objectin working condition use command RXBLI:MO=mo$,subord,force;RXESE:MO=mo$,subord;RXESI:MO=mo$,s ubord;RXBLE:MO=mo$,subord; (mo$ - RXOTG-tg$, RXOCF-tg$, RXOCON -tg$ ,RXOIS-tg$,RXOTRX-tg$-teivalue ,RXOTX-tg$- tei value,RXORX-tg$- tei value,RXOTS-tg$-tei value-timeslot no)Page 6. For finding the faulty managed object use command RXASP: MO=RXOTG- tg$; This alarm list contains various alarms like BTS INT UNAFFECTED, BTS INTAFFECTED, PERMANENT FAULT, some alarms can be removed by usingBLOCK/DEBLOCK commands. 7. For finding fault code on particular managed object (mo) use RXMFP: MO=mo$; This command shows fault code class and code some description is bellow IF mo$ is RXOCF then FAULT CODE IS 2A-33 RX diversity lost2A-8 VSWR limits exceeded2A-57 RX PATH IMBLANCE (VSWR)2A-39 RX cable disconnected (Related faults: RXORX 1B:9 RX cabledisconnected)2A:7 RXDA amplifier current faults (CDU FAULTY Need replacement ) 2A-21 internal power capacity reduced (PSU unit faulty or power off)2A-41 lost communication to TRU2A:23 Climate capacities reduced (Check fans and the Fan

Control Unit)2A:9 Power limits exceeded (Related faults: RXOTX 1B:2 TRU faulty needreplacement) If mo$ is RXOTRX then fault code is 1A-13 TX saturation (TRU FAULTY Need replacement)2A-12 TX output power limits exceeded (Related faults: TX 1B:13)block/deblock unit if not work Change TRU2A-13 TX saturation (Related faults: TX 1B:14 - TX saturation)block/deblock unit if not work Change TRU2A:25 TX max power restricted block /deblock unit if not work Change TRU2A:43 internal configuration fail block /deblock unit if not work Change TRU2A:42 Hardware IDB inconsistent check combiner chip & then IDBAny alarm found other than mentioned above on any manage object then pleaseconsult with MSC Gorakhpur 8. FOR replacement of TRU First get local mode on TRU by pressing Local /Remote button on TRU2 nd power off the TRU3 RD with the help of T10 Screw driver open the 2 pair screw on upper/lowerend of unit4 th replace the faulty unit with new one5 th power on and wait until Local Lamp get constant glow6

th again get remote status by pressing Local /Remote button on TRUPage 2 of 4

Wait for operation condition by 5minute if not operational block/deblock fromBSC if not work contact with MSC Gorakhpur Same processors adopt for CDU replacement (except Local/remote)Caution must be taken for wiring of units Tools (basic) used for hardware replacement are-32 wrench8/9 wrenchNoze pliersT10T8 For analysis of TCH BLOCKING 1. Find that site working in full configuration by using commandRXCDP: MO=RXOTGtg$; (ALL mo must be configured) If any BLOCKED found then use command RXASP: MO=RXOTG-tg$; (to find the all alarm and reason of block)IF LOCAL MODE found than try to make REMOTE otherwiseCheck the fault code by commandRXMFP:MO=mo$; (to find the exact fault code to make decision thathardware if faulty or not if hardware is faulty and need replacement thenbook the fault to ericsson and if the hardware is not faulty theBLOCK/DEBLOCK to make unit operational ) If any mo not block then check the half rate is on or off For checking half rate use commandRLDHP: CELL=cell; (DHA=ON)If DHA not ON use command to on itRLDHC: CELL=cell, DHA=ON;If traffic is more than for witch site is

configured (as erlang B table ) thenincrease the value of half rate by using commandRLDHC: CELL=cell, DTHAMR=100, DTHNAMR=100;Erlang B tableTRU (Per sector) Traffic that supported on full rate1 2 . 2 E 2 8 . 0 E 3 1 4.5E4 21.4E5 28.5E6 35.8E7 43.1E8 50.5E If none of the above case so new BTS is required to release congestion Page 3 of 4

For analysis of TCH DROP/CALL DROP 1. find alarm of RXOCF i.e VSWR or RX diversity lost if present the get rectify it2. find alarm of TRU if any alarm the get rectified3. use command RLCRP:CELL=cell; and in output see the ICM band must be 1to 3 if ICM band is 4-5 then correspond TRU is faulty get replacement (for finding thecorresponding TRU use BPC no. in RLCRP: CELL=cell; and RXCDP: MO=RXOTG-tg$)4. check handover report form Network quality report that is handover isproperly work5. define handover if not present in neighbor list using the command RLNRP: CELL=cell, CELLR=all; ( for neighbor list) RLNRI: CELL=cell, CELLR=cellr; (for cellr add in neighbor list)Page 4 of 4 Atividade (69)