BASIC SPECIFICATIONS OF THE NexWay

Capacity
Rated capacity (kg) 750 900 1050 1200 1350 1600 1800 2000 2250 2500 3000

BASIC SPECIFICATIONS OF THE NexWay

and Speed
Number of persons 10 12 14 16 18 21 24 26 30 33 40 Rated speed (m/sec) 2.0 2.5 3.0 3.5 4.0 5.0 6.0 7.0

: Applicable

Control,
Number of elevators in a bank

Door and Operation Systems


Control system Door system 1-car selective collective Standard 1C-2BC VVVF control with microprocessor, VVVF control and 2-panel center Data Network opening CO System Standard , with multiple 2-panel side microprocessor opening 2S modules option , VFGH 4-panel center opening 2CO option 2-car selective collective option 2C-2BC* 1

: Applicable Operation system

: Not applicable

8.0

9.0

AI-22 group control system option * 2

AI-2200C group control system option

1 car 2 cars 3 cars

3C-AI-22 3C-AI-2200C 4C-AI-22 4C-AI-2200C 5C-AI-2200C 6C-AI-2200C 7C-AI-2200C 8C-AI-2200C

4 cars 5 cars 6 cars 7 cars 8 cars

Notes: 1. Capacity and number of persons are based on EN81-1 (1998). 2. Please consult our local subcontractor for specifications outside the table above. 3. The specifications in green frame ( ) are for the space saving models. 4. Refer to page 5 to 12 for the hoistway and machine room layout plans for the models with specifications marked in gray ( For the layouts for models with other specifications, please consult our local subcontractor.

Notes: * 1. When the capacity and speed exceed the range shown in the left page, the operation system 2C-2BC should be 2C-AI-22. * 2. Please consult our local subcontractor, when 2C-AI-22 system is required instead of 2C-2BC system. ).

Selective collective (2BC)


Specifications
Rated speed Maximum number of stops Maximum travel (m) Minimum floor height (mm) 2.0 2.5 3.0 3.5 4.0 5.0 6.0 7.0 8.0 9.0 128: One gate (1D1G), 64: Two gates (1D2G & 2D2G) 150 *1 2500 *2 200 *1 250 *1

AI-22 AI-2200C Group Control Systems


The systems, which employ an intelligent expert system and fuzzy logic, are specially designed for group control of 3 to 8 elevators (as described above). Practical information required for group control is stored in the system's memory as a "Knowledge Database". Drawing from this database, various traffic conditions are monitored and analyzed applying IFTHEN decision rules to maximize the effectiveness of each elevator operation. The systems perform assignments to the most-used locations, and thereby provide superb efficiency and service. In addition to the above, AI-2200C system performs optimal car allocation using Dynamic Rule-set Optimizer.

Notes: *1 Please consult our local subcontractor if the maximum travel exceeds the values specified in the table above. *2 For some elevator specifications, the floor height (distance between floors) must be a minimum of 2500mm. Please consult us if the floor height is less than Entrance height HH + 700mm.

The system consists of call buttons in the car, and a riser of up and down destination floor buttons installed at each elevator hall (single button at terminal floors), which connect electrically with microprocessors supervising floor selection and direction of travel. A car will respond to those car and hall calls that comply with its direction of service. When there are no more calls registered for the car's direction of travel, the car's service direction is reversed.

RATED SPEED OF 2.03.0 m/sec

100-125 R1 AM (min)

RATED SPEED OF 2.03.0 m/sec

Car frame height (HB) according to car design and car depth
Car frame height (HB) (mm) 3450 3650 Car designs S10 S20 S30 N10 N20 BB1400 BB1400 N30 N40 N50 N60 N70 N80

BB BH

BM (min)

Ventilator (by owner)

Access door : (by owner)

Ventilation window (by owner)

Note: The dimensions HB are calculated when the ceiling height (HL) is 2300mm and without the emergency exit on ceiling. Please consult our local subcontractor if required the emergency exit.

Width: 1000 Height: 2000

JJ AA AH

R2

Top clearance (TC)


Rated speed (m/sec) 2.0 2.5 Travel (TR) (m) TR100 1760 1840 2190

(Unit: mm)

Machine-room height (HM)


Rated speed (m/sec)

(Unit: mm)

Control panel

Control panel

Attachment panel

Regulation EN81-1

Hoistway

Power outlet (by owner) Power receiving box (by owner)

100TR150 1910 1990 2340

Lighting outlet (by owner)

Intercom (option)

Machine room

3.0

2.0 2.5 3.0

2500

Reaction loads in machine room and pit


Rated speed (m/sec) R1 2.0 2.5 R2 P1 P2 R1 R2 3.0 P1 P2 Rated capacity (kg) 750 114 78 146 135 900 112 78 146 132 120 81 147 134 1050 112 77 146 129 132 90 171 155 1200 130 87 175 155 141 93 185 166 1350 140 95 191 169 143 97 191 169

(Unit: kN)

Pit-depth (PD) *2
Travel TR (m) TR100 2.0 100TR120 120TR150 TR100 2080 750

(Unit: mm)
Rated capacity (kg) 900 1050 1200 1350 1600 2080 2800 3000 3020

Overhead-height (OH) *2
Travel TR (m) TR100 2.0 100TR120 120TR150 TR100 5290 5440 5640 5790 Rated capacity (kg) 750 900

(Unit: mm)
Hoisting hook or trolley beam (by owner)

1600 147 99 198 172 148 100 200 174

Rated speed (m/sec)

Rated speed (m/sec)

1050 1200 1350 5210 5360

1600
HM (min.) Cinder-concrete finish (by owner)

5360
TC

2.5

100TR120 120TR150 TR100

2840 3040 3060 2650 3330 3130 3330 3350

2.5

100TR120 120TR150 TR100

5440
OH (min.) Entrance height: HH=2100

3.0

100TR120 120TR150

3.0

Dimension table of car, hoistway and machine room


Car internal dimensions (mm) Internal dimensions of hoistway (mm) *2 In-line arrangement 2-unit 3-unit 4-unit 1-unit installation installation installation installation Internal dimensions of machine room (mm) In-line arrangement Facing arrangement *3 6 units Width AM 6200 6550 6550 7150 7750 7750 8 units Width AM 8200 8750 8750 9550 10350 10350

Highest floor

Code number

1-unit 2-unit 3-unit 4-unit installation installation installation installation 4 units Width x Depth Width x Depth Width x Depth Width x Depth Width AM x BM AM x BM AM x BM AM x BM AM 2350 x 3455 4200 x 3455 6200 x 3455 8200 x 3455 2350 x 3455 4350 x 3455 6550 x 3455 8750 x 3455 2350 x 3655 4350 x 3655 6550 x 3655 8750 x 3655 2500 x 3655 4750 x 3655 7150 x 3655 9550 x 3655 4200 4350 4350 4750

Width x Depth Width x Depth Width x Depth Width x Depth Width x Depth AA x BB AH x BH AH x BH AH x BH AH x BH 2.0 2.5 P 10 P 12 2.0 2.5 3.0 P 14 P 16 P 18 P 21 750 900 1050 1200 1350 1600 10 12 14 16 18 21 800 900 900 1000 1100 1100 1400 x 1300 2000 x 2050 3900 x 2050 5900 x 2050 7900 x 2050 1600 x 1300 2300 x 2050 4300 x 2050 6500 x 2050 8700 x 2050 1600 x 1500 2300 x 2250 4300 x 2250 6500 x 2250 8700 x 2250 1800 x 1500 2500 x 2250 4700 x 2250 7100 x 2250 9500 x 2250 2000 x 1500 2700 x 2250 5100 x 2250 7700 x 2250 10300 x 2250 2000 x 1700 2700 x 2450 5100 x 2450 7700 x 2450 10300 x 2450

Lowest floor PD (min.)

2700 x 3655 5150 x 3655 7750 x 3655 10350 x 3655 5150 2700 x 3855 5150 x 3855 7750 x 3855 10350 x 3855 5150

Notes: * 1. All the above dimensions are calculated based on EN81-1 (1998). * 2. The dimensions PD, OH and BH are calculated when the counterweight without safety gear is located in back of the car. * 3. These machine room depth BM with a facing arrangement should be (2BH+3500) mm when lobby width is 3.5m. * 4. The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD. Necessary tolerance should be separately considered for the building construction errors. * 5. The dimensions TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table and conditions.

TravelTR

Rated speed (m/sec)

Rated capacity (kg)

Number of persons

Entrance width JJ (mm)

Total height

HL
P1

Note: The dimensions OH are calculated when the car frame height (HB) is 3450mm.

HB
P2

100TR150

Hoistway section
6

RATED SPEED OF 3.5, 4.0 m/sec


AM (min) 100-125
R1

RATED SPEED OF 3.5, 4.0 m/sec

Ventilator (by owner)

Car frame height (HB) according to car design and car depth
Car frame height (HB) (mm) 3450 Car designs S10 S20 S30 N10 N20 BB1400 BB1400 N30 N40 N50 N60 N70 N80

Ventilation window (by owner)

BB

BH

Attachment panel Attachment panel

Attachment panel

Control panel

Control panel

Control panel

Elevator lobby

Attachment panel

Control panel

Control panel

Control panel

Group control panel

Intercom (option)

Access door : (by owner) Width: 1000 Height: 2000

AH

JJ AA Lobby width: 3500-4500

R2

BM (min) = lobby width + 2BH

3650

Note: The dimensions HB are calculated when the ceiling height (HL) is 2300mm and without the emergency exit on ceiling. Please consult our local subcontractor if required the emergency exit.

Power outlet (by owner) Power receiving box (by owner) Lighting outlet (by owner)

Top clearance (TC)


Rated speed (m/sec) 3.5 4.0 Travel (TR) (m) TR100 2520 3070

(Unit: mm)

Machine-room height (HM)


Rated speed (m/sec) 3.5 4.0 Regulation EN81-1 2500

(Unit: mm)

BH

100TR120 120TR150 2670

Hoistway

Machine room

Reaction loads in machine room and pit


Rated speed (m/sec) R1 R2 3.5 P1 P2 R1 R2 4.0 P1 P2 146 133 171 155 132 93 174 158 185 166 139 96 185 166 191 169 141 99 191 169 Rated capacity (kg) 750 900 117 82 1050 131 92 1200 139 95 1350 141 99

(Unit: kN)

Pit-depth (PD) *2
Travel TR (m) TR100 3.5 100TR120 120TR150 4.0 TR150 3570 750

(Unit: mm) Rated capacity (kg) 900 1050 1200 1350 1600 3020 3370 3570 3590 3920

Overhead-height (OH) *2
Travel TR (m) TR100 3.5 100TR150 4.0 TR150 6120 750

(Unit: mm) Rated capacity (kg)


Hoisting hook or trolley beam (by owner)

1600 146 101 200 174 146 101 200 174

Rated speed (m/sec)

Rated speed (m/sec)

900 1050 1200 1350 1600 5970


HM (min.) Cinder-concrete finish (by owner)

6520

OH (min.)

Entrance height: HH=2100

Dimension table of car, hoistway and machine room


Car internal dimensions (mm) Internal dimensions of hoistway (mm) *2 In-line arrangement 2-unit installation 3-unit installation 4-unit installation Internal dimensions of machine room (mm) In-line arrangement 2-unit installation 3-unit installation 4-unit installation Facing arrangement *3 4 units 6 units Width AM 6650 6650 7250 7850 7850 8 units Width AM 8900 8900 9700 10500 10500

Highest floor

Width x Depth Width x Depth Width x Depth Width x Depth AA x BB AH x BH AH x BH AH x BH 3.5 P 12 P 14 3.5 4.0 P 16 P 18 P 21 900 1050 1200 1350 1600 12 14 16 18 21 900 900 1000 1100 1100 1600 x 1300 4400 x 2100 6650 x 2100 8900 x 2100 1600 x 1500 4400 x 2300 6650 x 2300 8900 x 2300 1800 x 1500 4800 x 2300 7250 x 2300 9700 x 2300 2000 x 1500 5200 x 2300 7850 x 2300 10500 x 2300 2000 x 1700 5200 x 2500 7850 x 2500 10500 x 2500

Width x Depth Width x Depth Width x Depth Width AM x BM AM x BM AM x BM AM 4400 x 3455 6650 x 3455 8900 x 3455 4400 x 3655 6650 x 3655 8900 x 3655 4800 x 3655 7250 x 3655 9700 x 3655 5200 x 3655 7850 x 3655 10500 x 3655 5200 x 3855 7850 x 3855 10500 x 3855 4400 4400 4800 5200 5200

Lowest floor PD (min.)

P2

P1

Travel (TR)

Rated speed (m/sec)

Code number

Rated capacity (kg)

Number of persons

Entrance width JJ (mm)

Total height

HL P1

Notes: * 1. All the above dimensions are calculated based on EN81-1 (1998). * 2. The dimensions PD, OH and BH are calculated when the counterweight without safety gear is located in back of the car. * 3. These machine room depth BM with a facing arrangement should be (2BH+3500) mm when lobby width is 3.5m. * 4. The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD. Necessary tolerance should be separately considered for the building construction errors. * 5. The dimensions TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table and conditions.

Hoistway section

HB P2

TC

Note: The dimensions OH are calculated when the car frame height (HB) is 3450mm.

RATED SPEED OF 5.0 m/sec


AM (min) 100-125
R1

RATED SPEED OF 5.0 m/sec

Ventilator (by owner)

Car frame height (HB) dimensions according to car design and car depth
Car frame height (HB) (mm) Car designs S10 S20 S30 N10 N20 N30 N40 N50 N60 N70 N80

Ventilation window (by owner)

BB

BH

BM (min) = lobby width + 2BH

3600 4000

AH

JJ AA Lobby width: 3500-4500


Reactor panel Control panel

R2
Group control panel
Reactor panel Control panel Reactor panel Control panel

Intercom (option) Distribution panel


Distribution panel

Elevator lobby

Reactor panel

Control panel

Reactor panel

Control panel

Reactor panel

Control panel

Access door (by owner): Width: 1600 or 1900 Height: 2000

Note: The dimensions HB are calculated when the ceiling height (HC) is 2300mm and without the emergency exit on ceiling. Please consult our local subcontractor if required the emergency exit.

Power outlet (by owner)

Top clearance (TC) dimensions


Rated speed (m/sec) 5.0 Travel (TR) (m) TR150 3200

(Unit: mm)

Machine-room height (HM)


Travel (TR) (m) TR150 150TR200 2300 1200 1350 1600 2300

(Unit: mm)

Power receiving box (by owner) BH Lighting outlet (by owner)

150TR200 3600

Rated speed (m/sec) 5.0

Rated capacity (kg) 1800

Hoistway

Machine room

2800

Reaction loads in machine room and pit


Rated speed (m/sec) R1 R2 5.0 P1 P2 Rated capacity (kg) 1800 1200 175 115 210 195 1350 180 120 220 200 1600 TR150 185 125 230 210 190 145 255 230

(Unit: kN)

Pit-depth (PD) dimensions


Travel TR (m) TR150 150TR200

(Unit: mm)

Overhead-height (OH) dimensions


Travel TR (m) TR150 150TR200

(Unit: mm)
Hoisting hook or trolley beam (by owner)

150TR200 225 155 260 235 5.0 3950 4250 5.0 6800 7200

HM (min.)

Rated speed (m/sec)

Rated capacity (kg) 1200 1350 1600 1800

Rated speed (m/sec)

Rated capacity (kg) 1200 1350 1600 1800

Cinder-concrete finish (by owner)

Code number Rated speed (m/sec)

Rated capacity (kg)

Number of persons

Entrance width JJ (mm)

Car internal dimensions (mm)

Internal dimensions of hoistway (mm) *2 In-line arrangement 2-unit installation 3-unit installation 4-unit installation

Internal dimensions of machine room (mm) In-line arrangement Facing arrangement *3


Highest floor

Entrance height: HH=2100

2-unit 3-unit 4-unit installation installation installation 4 units 6 units 8 units Width x Depth Width x Depth Width x Depth Width AM x BM AM x BM AM x BM AM 5500 x 3800 8100 x 3800 10700 x 3800 5500 5700 x 3800 8500 x 3800 11300 x 3800 5700 5700 x 4050 8500 x 4050 11300 x 4050 5700 TR150 5800 x 4150 8700 x 4150 11600 x 4150 5800 Width AM 8100 8500 8500 8700 8800 Width AM 10700 11300 11300 11600 11700

Total height

Width x Depth Width x Depth Width x Depth Width x Depth AA x BB AH x BH AH x BH AH x BH P 16 P 18 P 21 P 24 1200 1350 1600 1800 16 18 21 24 1000 1100 1100 1100 1800 x 1450 5100 x 2300 7700 x 2300 10300 x 2300 2000 x 1450 5500 x 2300 8300 x 2300 11100 x 2300 2000 x 1700 5500 x 2550 8300 x 2550 11100 x 2550 2100 x 1750 5700 x 2650 8600 x 2650 11500 x 2650

Lowest floor PD (min.)

150TR200 5900 x 4150 8800 x 4150 11700 x 4150 5900 Notes: * 1 All the above dimensions are calculated based on EN81-1 code (1998). * 2 The dimensions BH are calculated when the counterweight is equipped without safety gear. * 3 These are the machine room width dimensions with a facing arrangement and a lobby width of 3.5m. * 4 The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD. Necessary tolerance should be separately considered for the building construction errors. * 5 TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table. (When the counterweight is back drop.) * 6 The shaft independently housing a single car is not recommended because noise increases. Please consult our local subcontractor if the shaft of that kind is required.

P2

P1

Travel (TR)

HL P1

Hoistway section

HB P2

Dimension table of car, hoistway and machine room

OH (min.)

TC

Note: The dimensions OH are calculated when the car frame height (HB) is 3600mm.

10

RATED SPEED OF 6.0 m/sec


AM (min) 100-125
R1

RATED SPEED OF 6.0 m/sec

Ventilator (by owner)

Car frame height (HB) dimensions according to car design and car depth
Car frame height (HB) (mm) 3600 Car designs S10 S20 S30 N10 N20 N30 N40 N50 N60 N70 N80

Ventilation window (by owner)

BB

BH

BM (min) = lobby width + 2BH

4000

Reactor panel

Control panel

Reactor panel

Control panel

Reactor panel

Control panel

Intercom (option) Distribution panel


Distribution panel

Elevator lobby

Reactor panel

Control panel

Reactor panel

Control panel

Reactor panel

Control panel

Access door (by owner): Width: 1600 or 1900 Height: 2000

AH

JJ AA Lobby width: 3500-4500

R2

Group control panel

Note: The dimensions HB are calculated when the ceiling height (HC) is 2300mm and without the emergency exit on ceiling. Please consult our local subcontractor if required the emergency exit.

Power outlet (by owner)

Top clearance (TC) dimensions


Rated speed (m/sec) 6.0 Travel (TR) (m) TR150 3200

(Unit: mm)

Machine-room height (HM)


Travel (TR) (m) TR150 150TR200 2300 1200 1350 1600 2300

(Unit: mm)

Power receiving box (by owner) BH Lighting outlet (by owner)

150TR200 3600

Rated speed (m/sec) 6.0

Rated capacity (kg) 1800

Hoistway

Machine room

2800

Reaction loads in machine room and pit


Rated speed (m/sec) R1 R2 6.0 P1 P2 Rated capacity (kg) 1800 1200 175 125 205 195 1350 180 130 215 200 1600 TR150 175 135 225 200 190 145 255 230

(Unit: kN)

Pit-depth (PD) dimensions


Travel TR (m) TR150 150TR200

(Unit: mm)

Overhead-height (OH) dimensions


Travel TR (m) TR150 150TR200

(Unit: mm)
Hoisting hook or trolley beam (by owner)

150TR200 225 155 260 235 6.0 3950 4250 6.0 6800 7200

HM (min.)

Rated speed (m/sec)

Rated capacity (kg) 1200 1350 1600 1800

Rated speed (m/sec)

Rated capacity (kg) 1200 1350 1600 1800

Cinder-concrete finish (by owner)

Code number Rated speed (m/sec)

Rated capacity (kg)

Number of persons

Entrance width JJ (mm)

Car internal dimensions (mm)

Internal dimensions of hoistway (mm) *2 In-line arrangement 2-unit installation 3-unit installation 4-unit installation

Internal dimensions of machine room (mm) In-line arrangement Facing arrangement *3


Highest floor

Entrance height: HH=2100

2-unit 3-unit 4-unit installation installation installation 4 units 6 units 8 units Width x Depth Width x Depth Width x Depth Width AM x BM AM x BM AM x BM AM 5800 x 3800 8400 x 3800 11000 x 3800 5800 5700 x 3800 8500 x 3800 11300 x 3800 5700 5700 x 4050 8500 x 4050 11300 x 4050 5700 TR150 5800 x 4150 8700 x 4150 11600 x 4150 5800 Width AM 8400 8500 8500 8700 8800 Width AM 11000 11300 11300 11600 11700

Total height

Width x Depth Width x Depth Width x Depth Width x Depth AA x BB AH x BH AH x BH AH x BH P 16 P 18 P 21 P 24 1200 1350 1600 1800 16 18 21 24 1000 1100 1100 1100 1800 x 1450 5100 x 2300 7700 x 2300 10300 x 2300 2000 x 1450 5500 x 2300 8300 x 2300 11100 x 2300 2000 x 1700 5500 x 2550 8300 x 2550 11100 x 2550 2100 x 1750 5700 x 2650 8600 x 2650 11500 x 2650

Lowest floor PD (min.)

150TR200 5900 x 4150 8800 x 4150 11700 x 4150 5900 Notes: * 1 All the above dimensions are calculated based on EN81-1 code (1998). * 2 The dimensions BH are calculated when the counterweight is equipped without safety gear. * 3 These are the machine room width dimensions with a facing arrangement and a lobby width of 3.5m. * 4 The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD. Necessary tolerance should be separately considered for the building construction errors. * 5 TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table. (When the counterweight is back drop.) * 6 The shaft independently housing a single car is not recommended because noise increases. Please consult our local subcontractor if the shaft of that kind is required.

P2

P1

Travel (TR)

HL P1

Hoistway section

11

HB P2

Dimension table of car, hoistway and machine room

OH (min.)

TC

Note: The dimensions OH are calculated when the car frame height (HB) is 3600mm.

12

ENTRANCE LAYOUT DRAWINGS


Type E-102 (standard) Type E-302, E-312 (option)

ENTRANCE LAYOUT DRAWINGS

Door plan (section B-B)

Hoistway entrance Door elevation (section A-A)


Building structure (by owner) Wall and floor finishing (by owner) Note: 1. Triangular key-hole is required under EN81-1. 2. Details in sections A-A and B-B are not for BS-476 fire rated doors. Building structure (by owner) Wall and floor finishing (by owner) Note: 1. Triangular key-hole is required under EN81-1. 2. Details in sections A-A and B-B are not for BS-476 fire rated doors.

13

14