Analog Input Modules for Compact FieldPoint and FieldPoint

NI [c]FP-AI-100, NI [c]FP-AI-102, NI [c]FP-AI-110, NI [c]FP-AI-111


8 or 16 voltage or current inputs 120 V input range, maximum 0 to 20, 4 to 20 mA input ranges Built-in signal conditioning 50, 60, and 500 Hz noise rejection 12 and 16-bit resolution Software-configurable input ranges per channel 2,300 Vrms bank isolation for transient overvoltage protection Hot-swappable with autoconfiguration -40 to 70 C operating range

NEW

Module [c]FP-AI-100 [c]FP-AI-102 [c]FP-AI-110 [c]FP-AI-111

Input Channels 8 8 8 16

Resolution 12 bits 12 bits 16 bits 16 bits

Input Type Voltage Current Voltage Voltage Current Current

Input Ranges (Software Configurable per Channel) 1 V, 5 V, 15 V, 30 V, 0 to 1 V, 0 to 5 V, 0 to 15 V, 0 to 30 V 0 to 20 mA, 4 to 20 mA, 20 mA 20 V, 60 V, 120 V, 0 to 20 V, 0 to 60 V, 0 to 120 V 60 mV, 300 mV, 1 V, 5 V, 10 V, 0 to 1 V, 0 to 5 V, 0 to 10 V 0 to 20 mA, 4 to 20 mA, 20 mA 0 to 20 mA, 4 to 20 mA, 20 mA

50/60 Hz Noise Filter (software selectable) (software selectable)

All-Channel Update Rate 360 Hz 360 Hz 5 Hz to 0.66 Hz (rate varies with filter settings) 3 Hz to 0.83 Hz (rate varies with filter settings)

Overview
The National Instruments [c]FP-AI-1xx devices are versatile analog input modules for Compact FieldPoint and FieldPoint that can be used to measure voltages ranging from the millivolt level to the 120 V high-voltage level in applications such as battery-pack monitoring, fuel-cell testing, and general measurement from transducers. These modules can also measure 0 to 20 or 4 to 20 mA current loops from industrial sensors and transmitters. All the modules include overranging and onboard diagnostics to ensure trouble-free installation and maintenance. The modules measure and linearize signals on-board to return scaled values to your control or monitoring software. The [c]FP-AI-1xx modules come with NIST-traceable calibration certificates, ensuring accurate and reliable analog measurements.

Smart I/O Modules


With [c]FP-AI-1xx analog input modules, you can directly connect to your industrial sensors or units under test and get high-accuracy measurements. The I/O modules filter, calibrate, and scale raw sensor signals to engineering units, as well as performing self-diagnostics to

look for problems with the module or the wiring. With FieldPoint modules, your software application reads a linearized, calibrated, and scaled value from the I/O module, eliminating the error-prone step of converting binary values to voltage or current values. For increased accuracy and noise rejection, the [c]FP-AI-110 and [c]FP-AI-111 use a 16-bit delta-sigma ADC with an integrated lowpass filter on each channel, which you can configure for 50 Hz, 60 Hz, or no rejection. With high-accuracy 12-bit ADCs or 16-bit delta-sigma ADCs on the I/O modules, you also get instrument-quality measurements on an industrially rugged, distributed, embedded system. [c]FP-AI-1xx modules offer a variety of update rates to fit your application, ranging from 0.66 to 360 Hz. These rates vary based on the module used and on the noise filter settings selected on the module. Overall data throughput depends on software loop speeds and network speeds. With overranging and underranging, the [c]FP-AI-1xx analog input modules can measure inputs or sensors that are not calibrated to standard ranges. For example, when configured for an input range of 4 to 20 mA, the modules actually measure inputs from 3.5 to 21 mA.

Thermocouple and RTD Modules for Compact FieldPoint


NI cFP-TC-120, NI cFP-TC-125, NI cFP-RTD-122, NI cFP-RTD-124
8 temperature inputs Thermocouple or millivolt 2, 3, or 4-wire RTD Built-in signal conditioning between channels 250 V common-mode isolation on TC-125 50 and 60 Hz noise rejection 16-bit resolution Input ranges configurable in software for each channel 2,300 Vrms bank isolation for transient overvoltage protection Hot-swappable with autoconfiguration -40 to 70 C operating range

Module cFP-TC-120 cFP-TC-125 cFP-RTD-122 cFP-RTD-124

Input Channels 8 8 8 8

Resolution (bits) 16 16 16 16

Input Type Thermocouple Millivolt Thermocouple Millivolt 2, 3-Wire RTD Resistance 2, 4-Wire RTD Resistance

Input Ranges Software Configurable per Channel J,K,R,S,T,N,E, and B 25 mV, 50 mV, 100 mV, -20 to 80 mV J,K,R,S,T,N,E, and B -20 to 80 mV Pt 100, Pt 1,000 0 to 400, 0 to 4000 Pt 100 0 to 400

50/60 Hz Noise Filter    

All-Channel Update Period 1.13 s (0.88 Hz) 0.22 s (Filter Off) 0.99 s (Filter On) 1.08 s (0.93 Hz) 1.08 s (0.93 Hz)

Common-Mode Between Channels 250 Vrms

Safety Isolation 2,300 Vrms bank isolation 2,300 Vrms bank isolation 2,300 Vrms bank isolation 2,300 Vrms bank isolation

Overview
The National Instruments cFP-TC-12x and cFP-RTD-12x are versatile temperature input modules for Compact FieldPoint, used to measure thermocouples, millivolt-level voltages, thermistors, and 2, 3, and 4-wire RTDs. They are used in applications such as temperature chamber control, device testing, and process control. Thermocouples are low-cost, flexible temperature devices. RTD sensors are used in applications for acquiring temperatures with high accuracy. Two and 3-wire RTDs work well for applications with short signal wires and low noise levels; 4-wire RTDs are well-suited for applications with long signal wires or high noise levels. All of these I/O modules include overranging and onboard diagnostics to ensure trouble-free installation and maintenance. The modules measure and linearize signals on board to return scaled values to your control or monitoring software. NI cFP-TC-12x and cFP-RTD-12x modules have NISTtraceable calibration certificates (available on request), ensuring accurate and reliable analog measurements.

Compact FieldPoint
Compact FieldPoint is designed for industrial control applications that perform advanced embedded control, data logging, headless operation, and Ethernet connectivity. Compact FieldPoint, a rugged, reliable NI platform, is designed for industrial and mobile environments with high shock, vibration, and temperature extremes.

Isolation
The cFP-TC-125 provides 250 Vrms common-mode voltage protection between channels, and all cFP-TC-12x and cFP-RTD-12x modules feature optical bank isolation with 2,300 Vrms of breakdown isolation. In addition, the cFP-TC-12x and cFP-RTD-12x provide double insulation for up to 250 Vrms of operational isolation. You can safely use Compact FieldPoint with the cFP-CB-1 or cFP-CB-3 connector block in applications where hazardous voltages are present.

Thermocouple and RTD Modules for Compact FieldPoint


cFP-RTD-124
The cFP-RTD-124 includes eight inputs for 2 and 4-wire RTDs. The module uses a stable current source for sensor excitation and an onboard microcontroller that linearizes and scales the measurements to temperature units. You can configure each channel of the modules to return data scaled to temperature (C, F, or K) or resistance. Four-wire RTDs used with the cFP-RTD-124 are ideal for applications involving long signal wires or high signal noise. The 4-wire configuration eliminates the voltage drop caused by lead wire resistance and reduces errors caused by noise.

Smart I/O Modules


The cFP-TC-12x and cFP-RTD-12x modules offer 16-bit resolution for high-accuracy measurements, and you can connect directly to industrial sensors or units under test with the safety isolation available. The modules filter, calibrate, and scale raw sensor signals to engineering units, as well as perform self-diagnostics to look for problems such as open thermocouples. With cFP-TC-12x and cFP-RTD-12x modules, your software application reads a linearized, calibrated, scaled value from the I/O module, eliminating the error-prone step of converting binary values to temperature. For increased accuracy and noise rejection, the modules use a 16-bit delta-sigma ADC with an integrated lowpass filter on each channel, which is configured for 50 and 60 Hz rejection. With high-accuracy 16-bit delta-sigma ADCs on the I/O modules, you also get instrument-quality measurements on an industrially rugged, distributed, embedded system. cFP-TC-12x and cFP-RTD-12x modules offer a variety of different update rates to fit your application, ranging from 0.22 s with filters off and 1.08 to 1.13 s with filters enabled. Overall data throughput depends on filter settings across all channels, software loop speeds, and network speeds.

Isothermal Connectivity for the cFP-TC-12x


For maximum accuracy, NI recommends using an isothermal connector block with the cFP-TC-12x. The cFP-CB-3 isothermal connector block minimizes the temperature gradient across wiring connections, improving the accuracy of the cold-junction measurement, and, therefore, of thermocouple measurements.

Compact FieldPoint I/O Connections


Compact FieldPoint modules include a built-in power distribution bus that provides multiple power connections on the module. A field-wired power supply connected to the voltage (V) and common (C) terminals is internally connected to a power distribution bus that provides additional breakout terminals for voltage supply (VSUP) and common (COM). These terminals offer a convenient way to distribute power to field devices that require external power. Each cFP-TC-12x input channel has two terminals for differential input: 1. Thermocouple positive input (IN+) 2. Thermocouple negative input (IN-) Each cFP-RTD-122 input channel has three terminals: 1. Excitation output (EXCITE) 2. Sensing input (SENSE) 3. Common input (COM) Each cFP-RTD-124 input channel has four terminals: 1. Excitation output (EXCITE) 2. Positive sensing input (SENSE+) 3. Negative sensing input (SENSE-) 4. Common input (COM)

cFP-TC-120
The cFP-TC-120 includes eight differential inputs for thermocouples. It also provides cold-junction compensation using a thermistor embedded in the connector block. An onboard microcontroller compensates and linearizes the thermocouple reading to the NIST IST-90 standard, using an advanced linearization routine for maximum accuracy.

cFP-TC-125
In addition to the thermistor and linearization features of the cFP-TC-120, the cFP-TC-125 provides 250 Vrms of common-mode rejection, ideal for applications where differences in voltages might exist between connected thermocouples. The cFP-TC-125 also provides 0.22 s update rates when the 50/60 Hz filter is not enabled.

cFP-RTD-122
The cFP-RTD-122 includes eight inputs for 2 and 3-wire RTDs. The module uses a stable current source for sensor excitation and an onboard microcontroller that linearizes and scales the measurements to temperature units. You can configure each channel of the module to return data scaled to temperature (C, F, or K) or resistance. The 3-wire configuration used with the cFP-RTD-122 eliminates errors caused by lead wire resistance but does not reduce errors caused by noise. If your application involves high noise or long wires, you should use 4-wire RTDs with the cFP-RTD-124.

BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)

Strain Gauge Modules for Compact FieldPoint And FieldPoint


NI [c]FP-SG-140
Accept full and half-bridge strain gauge inputs directly Quarter-bridge gauges require external bridge-completion resistor Compatible with load cells, force sensors, and torque sensors Built-in signal conditioning 15, 60, and 240 Hz noise rejection Pulsed excitation to prevent self-heating 16-bit resolution Input ranges software configurable per channel 2,300 Vrms bank isolation for transient overvoltage protection Hot-swappable with auto configuration -40 to 70 C operating range

NEW

Module [c}FP-SG-140

Input Channels 8

Resolution 16 bits

Input Ranges (Software Configurable per Channel) 3.5 mV/V, 7.5 mV/V, 30 mV/V, 60 mV/V

15/60/240 Hz Noise Filter Software selectable

All Channel Update Rate 1.11 to 0.87 Hz (rate varies with filter settings)

Overview
The National Instruments [c]FP-SG-140 is a versatile resistance bridge input module for Compact FieldPoint and FieldPoint that can be used to measure values from resistor bridges including full and half-bridge strain gauges, quarter-bridge strain gauges (using an external completion register), and load and torque sensors. The [c]FP-SG-140 includes builtin excitation, overranging, and onboard diagnostics to ensure trouble-free installation and maintenance. The module measures and linearizes signals onboard to return scaled values to your control or monitoring software. The [c]FP-SG-140 comes with a NIST-traceable calibration certificate, ensuring accurate and reliable analog measurements.

different excitation level of 2.5, 5, or 10 V. For increased accuracy and noise rejection, the [c]FP-SG-140 uses a 16-bit delta-sigma ADC with an integrated lowpass filter on each channel, which you can configure for 15, 60, or 240 Hz. With a high-accuracy 16-bit delta-sigma ADC, you also get instrument-quality measurements on an industrially rugged, distributed, embedded system. The [c]FP-SG-140 has three update rates to fit your application, ranging from 0.87 to 1.11 Hz. These rates vary based on the noise filter setting selected on the module. Overall data throughput depends on software loop speeds and network speeds. With overranging and underranging, the modules can zero out unstrained readings in software to compensate for field devices with span errors of up to 12 percent.

Smart I/O Modules


With the SG-140, you can connect directly to industrial sensors or units under test and get high-accuracy measurements. The module filters, calibrates, and scales raw sensor signals to engineering units, as well as performing self-diagnostics to look for problems with the module or with the wiring. With the SG-140 module, your software application reads a linearized, calibrated, and scaled value from the I/O module, eliminating the error-prone step of converting binary values. Because the [c]FP-SG-140 measures in units of millivolts per volt, it can interface with a wide variety of transducers, such as load cells and pressure sensors. The module uses a pulsed excitation of up to 21 mA per channel that turns on and off the excitation to each channel. This reduces self-heating effects and provides more accurate and repeatable strain measurements. The [c]FP-SG-140 also provides true ratiometric readings to eliminate errors caused by variations in excitation voltage. Each channel on the module can be configured for a

Isolation
The [c]FP-SG-140 features optical bank isolation with 2,300 Vrms of breakdown isolation. These Compact FieldPoint and FieldPoint modules do not have channel-to-channel isolation.

Field I/O Connections


Compact FieldPoint and FieldPoint modules include a built-in power distribution bus that provides multiple power connections on the module. A field-wired power supply connected to the voltage (V) and common (C) terminals is internally connected to a power distribution bus that provides additional breakout terminals for voltage supply (VSUP) and common (COM). These terminals provide a convenient way to distribute power to field devices that require external power.

Strain Gauge Modules for Compact FieldPoint And FieldPoint


Each input channel on the [c]FP-SG-140 has four terminals: 1. Excitation voltage output (Vexc) 2. Positive signal input (VIN+) 3. Negative signal input (VIN-) 4. Common input (COM)

Ordering Information
Compact FieldPoint

NI cFP-SG-140 ............................................................777318-140
Recommended Compact FieldPoint System Products

Vexc Quarter-Bridge Strain Gauges Vin+ Vin COM Input Circuitry + Excitation Voltage Half-Bridge Strain Gauges

Vexc Vin+ Vin COM Input Circuitry + Excitation Voltage

NI cFP-2020 ..............................................................777317-2020 NI cFP-BP-4 ..................................................................778617-04 NI cFP-CB-1 ..................................................................778618-01 NI PS-5 Power Supply ..................................................778805-90 NI Developer Suite Professional Control Edition..........777906-03
FieldPoint

External Completion Resistor

NI FP-SG-140 ..............................................................777518-140
[c]FP-SG-140

[c]FP-SG-140 Full-Bridge Strain Gauge

Recommended FieldPoint System Products

Vexc Vin+ Vin Input Circuitry + Excitation Voltage

COM

NI FP-1601 ....................................................................777792-01 NI FP-TB-1 ....................................................................777519-01 PS-4 Power Supply ........................................................778586-90 NI Developer Suite Standard Control Edition ............777905-03

[c]FP-SG-140

BUY ONLINE!
Visit ni.com/info and enter cfpsg140, and/or fpsg140.

Figure 1. Wiring Schematic for the [c]FP-SG-140 Module

Specifications
Typical for -40 to 70 C unless otherwise noted.

Environmental
FieldPoint modules are intended for indoor use only. For outdoor use, they must be mounted inside a sealed enclosure. Operating temperature..................................... -40 to 60 C Storage temperature ........................................ -55 to 85 C Relative humidity ............................................. 10 to 90%, noncondensing Maximum altitude ............................................ 2,000 m; at higher altitudes the isolation voltage ratings must be lowered. Pollution degree ............................................... 2

Input Characteristics
Number of inputs ............................................. Resolution......................................................... Type of ADC...................................................... Filters ............................................................... Excitation voltage............................................. 8 differential 16 bits, 1 in 65,536 Delta-sigma 15, 60, 240 Hz, user-selectable 2.5, 5, 10 V, user-selectable, current-limited to 21 mA per channel Bridge configurations ....................................... Half and full-bridge circuits, quarter-bridge with external completion resistor Gauge factor..................................................... Any (software value) Input impedance............................................... 20 M Offset error 15 to 35 C ................................................. 7.6 V typ, 28 V max 40 to 70 C............................................... 50 V typ, 140 V max Gain error 15 to 35 C ................................................. 0.06% 40 to 70 C............................................... 0.4% Input noise (60 Hz filter) 3.5 mV/V................................................. 3 LSBpp 7.5 mV/V................................................. 2 LSBpp Other ranges..................................................... 1 LSBpp All-channel update periods 15 Hz .......................................................... 1.15 s 60 Hz .......................................................... 0.95 s 240 Hz ........................................................ 0.90 s

Shock and Vibration


These specifications apply only to Compact FieldPoint. NI recommends Compact FieldPoint if your application is subject to shock and vibration. Operating vibration, random (IEC 60068-2-64) ........................................ 10500 Hz, 5 grms Operating vibration, sinusoidal (IEC 60068-2-6) .......................................... 10500 Hz, 5 g Operating shock (IEC 60068-2-27) ........................................ 50 g, 3 ms half sine, 18 shocks at 6 orientations; 30 g, 11 ms half sine, 18 shocks at 6 orientations

Safety
This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 3121-1, UL 61010C-1 CAN/CSA C22.2 No. 1010.1 For UL, hazardous location, and other safety certifications, refer to the product label or to ni.com

Isolation Voltage
Maximum isolation voltage ............................. 250 Vrms, Installation Category II Channel-to-channel isolation ........................... No isolation between channels Transient overvoltage....................................... 2,300 Vrms

Electromagnetic Compatibility
CE, C-Tick, and FCC Part 15 (Class A) Compliant Emissions.......................................................... EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity........................................................... EN 61326:1997 +A2:2001, Table 1 For EMC compliance, you must operate this device with shielded cabling.

Physical Characteristics
LED indicators POWER (green) .......................................... READY (green) ........................................... OVERCURRENT (red).................................. Dimensions (including terminal base).............. Weight FP-SG-140 .................................................. cFP-SG-140 ................................................ Power on and self-test passed Module configured and ready Overcurrent condition on channel 10.9 by 10.7 by 9.1 cm (4.3 by 4.2 by 3.6 in.) 140 g (4.8 oz) 110 g (3.7 oz)

CE Compliance
This product meets the essential requirements of applicable European Directives, as amended for CE Marking, as follows: Low-Voltage Directive (safety)......................... 73/23/EEC Electromagnetic Compatibility Directive (EMC) ................................................ 89/336/EEC Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/hardref.nsf/ and search by model number or product line.

Power Requirement
Power from network module............................ 1,000 mW

National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 info@ni.com ni.com

Analog Output Modules for Compact FieldPoint and FieldPoint


NI [c]FP-AO-200, NI [c]FP-AO-210
8 voltage or current outputs 0 to 10 V 0 to 20, 4 to 20 mA 12 -bit resolution Output ranges software configurable per channel 2,300 Vrms bank isolation for transient overvoltage protection Hot swappable with autoconfiguration -40 to 70 C operating range

NEW

Module [c}FP-AO-200 [c}FP-AO-210

Input Channels 8 8

Resolution 12 bits 12 bits

Output Types Current Voltage

Output Ranges (Software Configurable per Channel) 0 to 20 mA, 4 to 20 mA 0 to 10 V, (up to 10 mA/ch)

All Channel Update Rate 200 Hz 200 Hz

Overview
The National Instruments [c]FP-AO-2xx devices are versatile analog output modules for Compact FieldPoint and FieldPoint that can be used to control valves, gauges, and other industrial actuators. All modules include overranging and onboard diagnostics to ensure trouble-free installation and maintenance. The modules accept engineering units from you, control or monitoring software and linearize and output scaled signals. The NI [c]FP-AZ-2xx modules come with NIST-traceable calibration certificates, ensuring accurate and reliable analog control.

The [c]FP-AO-210 includes eight 0 to 10 V output channels, generated with a 12-bit DAC. Each channel provides a voltage source capable of supplying up to 1 mA. You can obtain up to 10 mA by powering the AO-210 with an optional external power supply of 15 to 30 VDC.

Isolation
The AO-xx series modules feature optical bank isolation with 2,300 Vrms of breakdown isolation. These Compact FieldPoint and FieldPoint modules do not have channel-to-channel isolation.

Smart I/O Modules


With AO-2xx modules, you can directly connect to your industrial actuators or units under test and get high-accuracy control. The I/O modules calibrate, and scale engineering units to sensor signals, as well as performing self-diagnostics to look for problems with the module or with the wiring such as open current loops. With AO-2xx modules, your software application writes an engineering value to the I/O module, eliminating the error-prone step of converting voltage or current to binary values. The A0-2xx modules have an update rate of 200 Hz. Overall data throughput to the controller or PC depends on the software loop speeds and the network speeds. The [c]FP-AO-200 includes eight 0 to 20 mA or 4 to 20 mA analog output channels, generated with a 12-bit DAC. Each output channel includes a monitoring circuit and LED indicator for open current loop detection. The AO-200 requires an external power supply that provides 5 to 24 VDC.

Field I/O Connections


Compact FieldPoint and FieldPoint modules include a built-in power distribution bus that provides multiple power connections on the module. A field wired power supply connected to the voltage (V) and common (C) terminals is internally connected to a power distribution bus that provides additional breakout terminals for voltage supply (VSUP) and common (COM). These terminals provide a convenient way to distribute power to field devices that require external power. The AO-200 has: 8 current output terminals (IOUT) 16 common terminals (COM) 8 power connections for field devices or current loops (VSUP) The AO-210 has: 8 voltage output terminals (VOUT) 16 common terminals (COM) 8 power connections for field devices or current loops (VSUP)

Analog Input/Output Combination Modules for Compact FieldPoint and FieldPoint


NI [c]FP-AIO-600
4 voltage or current inputs 30 V 0 to 20, 4 to 20 mA 4 current outputs 0 to 10 V 0 to 20, 4 to 20 mA 12-bit resolution Input and output ranges software configurable per channel 2,300 Vrms bank isolation for transient overvoltage protection Hot swappable with autoconfiguration -40 to 70 C operating range

NEW

Module [c}FP-AIO-600

Input Channels 4

Current Voltage

Input Ranges (Software Configurable per Channel) 0 to 20 mA, 4 to 20 mA 5 V, 15 V, 30 V, 0 to 5 V, 0 to 15 V, 0 to 30 V

Output Channels 4

Output Ranges (Software Configurable per channel) Current: 0 to 20 mA, 4 to 20 mA

Resolution 12 bits

All Channel Update Rate 1.7 kHz

Overview
The National Instruments [c]FP-AIO-600 is a versatile combination analog input and analog output modules for Compact FieldPoint and FieldPoint that can be used to measure voltages and 0 to 20 or 4 to 20 mA current loops from industrial sensors and transmitters and to control valves, gauges, and other industrial actuators. The NI [c]FP-AIO-600 is ideal for low-channel-count systems or for PID control with high speed I/O. The module has overranging and onboard diagnostics to ensure trouble-free installation and maintenance. The [c]FP-AIO-600 measures and linearizes signals onboard to return scaled values to your control or monitoring software and accept engineering units from you control or monitoring software and automatically scale and linearize output signals. The [c]FP-AIO-600 module comes with a NIST-traceable calibration certificate, ensuring accurate and reliable analog measurement and control.

Smart I/O Modules


You can connect the [c]FP-AIO-600 directly to industrial actuators or units under test and get high-accuracy measurement and control. The module calibrates, and scales engineering units to sensor signals, as well as performing self-diagnostics to look for problems with the module or with the wiring, such as open current loops. With the [c]FP-AIO-600s, your software application reads and writes engineering values from the module, eliminating the error-prone step of converting voltage or current to binary values. The module has an update rate of 1.7 kHz. Overall data throughput depends on the software loop speeds and the network speeds.

[c]FP-AIO-600
The [c]FP-AIO-600 includes four 0 to 30 V or 0 to 20/4 to 20 mA analog inputs and four 0 to 20/4 to 20 mA analog outputs. The analog inputs and outputs use a 12-bit DAC. Each output channel includes a monitoring circuit and LED indicator for open current loop detection. The [c]FP-AIO-600 requires an external power supply,providing 5 to 30 VDC.

Digital Input Modules for Compact FieldPoint and FieldPoint


NI [c]FP-DI-300, NI [c]FP-DI-301, NI cFP-DI-304, NI [c]FP-DI-330 NEW!
8,16, or 32 channel inputs 24 VDC inputs 4 to 250 VDC inputs 15 to 250 VAC inputs (50/60 Hz AC) 3 to 250 VAC inputs (1 kHz AC) 2,300 Vrms bank isolation for transient overvoltage protection Hot-swappable with autoconfiguration -40 to 70 C operating range

FieldPoint Software (included)


FieldPoint 5.0 (for all models)

Module [c]FP-DI-300 [c]FP-DI-301 cFP-DI-304 [c]FP-DI-330

Input Channels 8 16 32 8

Input Ranges 18 to 30 VDC 18 to 30 VDC 10 to 30 VDC 5 to 48 VDC 5 to 250 VAC

Input Type Sinking Sinking Sinking Sinking or sourcing

Compatibility Examples 24 VDC sourcing devices 24 VDC sourcing devices 24 VDC sourcing devices TTL, CMOS, 12 VDC, 24 VDC, 48 VDC, 120/240 VAC/VDC

Separate Ground Plane per Channel 

All Channel Update Rate 1 kHz 1 kHz 1 kHz 1 kHz

Additional Features Hysteresis Input current limiting (1.5 mA)

Overview
The National Instruments [c]FP-DI-3xx devices are versatile digital input modules. The DI-300, DI-301, and DI-330 are available in the Compact FieldPoint and FieldPoint product families. The new NI cFP-DI-304 module is available for Compact FieldPoint systems. You can use these modules to monitor digital signals ranging from low voltage levels up to 250 V. They are commonly used to monitor proximity and limit switches, pushbutton switches, thermostat outputs, relay closures, power circuits, and TTL devices. All the modules include onboard diagnostics to ensure trouble-free installation and maintenance.

the DI-3xx modules feature LEDs that indicate the input state of each channel. The modules feature an all channel update rate of 1 kHz. Overall data throughput depends on software loop speeds and network speeds.

Isolation
The [c]FP-DI-3xx modules feature bank isolation with 2,300 Vrms of breakdown isolation. In addition, the DI-330 provides double insulation for up to 250 Vrms of operational isolation. You can safely use Compact FieldPoint in applications where hazardous voltages are present when used with the cFP-CB-1 connector block. You can safely use FieldPoint in applications where hazardous voltages are present with the FP-TB-x terminal base. These Compact FieldPoint and FieldPoint modules do not have channel-to-channel isolation.

Digital Input Modules


The [c]FP-DI-3xx modules provide built-in module-to-module isolation to protect your FieldPoint system and controller or communication interface from high voltage levels. The DI-300, DI-301, and DI-304 modules use a common ground plane for all the input channels. Each channel on the DI-300, DI-301, and DI-304 modules include current-limiting circuitry to prevent module damage when connected directly to a 24 VDC source. The DI-330 uses eight optically isolated input channels so that each digital input has a separate ground plane, and you can use each channel with a different voltage potential. Thus, you can connect one channel to a 5 VDC TTL signal and another signal on the same DI-330 module to a 250 VAC line voltage. Each channel on the DI-330 includes current-limiting circuitry that limits the total current to 1.5 mA to prevent damaging the module. All channels on

Field I/O Connections


Compact FieldPoint and FieldPoint modules include a built-in power distribution bus that provides multiple power connections on the module. A field wired power supply connected to the voltage (V) and common (C) terminals is internally connected to a power distribution bus that delivers additional breakout terminals for voltage supply (VSUP) and common (COM). These terminals offer a convenient way to distribute power to field devices that require external power.

Digital Input Modules for Compact FieldPoint and FieldPoint


5-250 V External Power Supply V C + Input Circuitry V VSUP (Ch 0) VSUP (Ch 1) SourcingOutput Device with External Power INA (Ch 1) INB (Ch 1) COM (Ch 1) VSUP (Ch 2) SinkingOutput Device Powered by [c]FP-DI-330 INA (Ch 2) INB (Ch 2) COM (Ch 2) COM (Ch 1) VSUP (Ch 3) SourcingOutput Device Powered by [c]FP-DI-330 INA (Ch 3) INB (Ch 3) COM (Ch 3) Switch VSUP (Ch n) INA (Ch n) Switch INB (Ch n) COM (Ch n) Input Circuitry To next channel [c]FP-DI-300/301/304 COM (Ch n) Input Circuitry VIN (Ch n) Input Circuitry VSUP (Ch n) Input Circuitry Sourcing Output Device Powered by [c]FP-DI-30x Input Circuitry + + Sourcing Output Device with External Power C 15-30 VDC External Power Supply VIN (Ch 0) Input Circuitry COM (Ch 0) VSUP (Ch 1) VIN (Ch 1) Input Circuitry +

VSUP (Ch 0) SinkingOutput Device with External Power INA (Ch 0) INB (Ch 0) COM (Ch 0) +

To next channel [c]FP-DI-330

Wiring Schematics for the [c]FP-DI-3xx Modules

Ordering Information
Compact FieldPoint NI cFP-DI-300 ......................................................................777318-300 NI cFP-DI-301 ......................................................................777318-301 NI cFP-DI-304 ......................................................................777318-304 NI cFP-DI-330 ......................................................................777318-330 Recommended Compact FieldPoint System Products NI cFP-2120 ......................................................................777317-2120 NI cFP-BP-4 ............................................................................778617-04 NI cFP-BP-8 ............................................................................778617-08 NI cFP-CB-1............................................................................779618-01 NI PS-5 Power Supply ..........................................................778805-90 NI Developer Suite Professional Control Edition..................777906-03

FieldPoint NI FP-DI-300 ........................................................................777518-300 NI FP-DI-301 ........................................................................777518-301 NI FP-DI-330 ........................................................................777518-330 Recommended FieldPoint System Products NI FP-1601 ............................................................................777792-01 NI FP-TB-1..............................................................................777519-01 NI PS-4 Power Supply ..........................................................778586-90 NI Developer Suite Control Edition ......................................777905-03

BUY NOW!
For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S.) or go to ni.com.

BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)

Digital Output Modules for Compact FieldPoint and FieldPoint


NI [c]FP-DO-400, NI [c]FP-DO-401, NI [c]FP-DO-403, NI [c]FP-DO-410
8 or 16 digital outputs 5 VDC 12 VDC 24 VDC Fused outputs for short circuit protection (DO-410) 2,300 Vrms bank isolation for transient overvoltage protection Hot swappable with autoconfiguration -40 to 70 C operating range

NEW

Module [c]FP-DO-400 [c]FP-DO-401 [c]FP-DO-403 [c]FP-DO-410

Output Channels 8 16 16 8

Output Ranges 10 to 30 VDC, sourcing 10 to 30 VDC, sourcing 5 to 30 VDC, sinking 5 to 30 VDC, sourcing

Output Current Rating (see Specifications for More Details) 2A 2A 2A 1A

Compatibility Examples 12 and 24 VDC 12 and 24 VDC 5, 12, and 24 VDC 5, 12, and 24 VDC

Electronically Fused Outputs

All Channel Update Rate 20 kHz 20 kHz 20 kHz 20 kHz

Overview
The National Instruments [c]FP-DO-4xx devices are versatile digital output modules for Compact FieldPoint and FieldPoint that can be used to control digital signals ranging from 5 to 30 volts. These modules are commonly used to control indicator lights, external relays, and CMOS and TTL devices. All the modules include onboard diagnostics to ensure trouble-free installation and maintenance.

Digital Output Modules


The DO-4xx modules provide built-in module-to-module isolation to protect your FieldPoint system and controller or communication interface from high voltage levels. All the digital output modules use a common ground plane for the digital output channels. The DO-400 and DO-401 modules are sourcing digital output modules capable of providing up to 2 A per channel, with a maximum power limit across the entire module as explained in the specifications section.

The DO-403 modules are sinking digital output modules capable of providing up to 2 A per channel, with a maximum power limit across the entire module as explained in the specifications section. The DO-410 modules are sourcing digital output modules capable of providing up to 1 A per channel. They also feature an electronic fuse that will prevent damage to the module due to short circuits or other overcurrent situations. The fuses automatically reset when the output returns to a normal state. An LED indicates an overcurrent fault. All the channels on the DO-4xx modules feature LEDs that indicate the output state of each channel. The modules all feature an all channel update rate of 20 kHz. Overall data throughput depends on software loop speeds and network speeds.

Isolation
The DO-4xx modules feature optical bank isolation with 2,300 Vrms of breakdown isolation. These Compact FieldPoint and FieldPoint modules do not have channel-to-channel isolation.

Digital Output Modules for Compact FieldPoint and FieldPoint


Field I/O Connections
The Compact FieldPoint and FieldPoint modules include a built-in power distribution bus that provides multiple power connections on the module. A field-wired power supply connected to the voltage (V) and common (C) terminals is internally connected to a power distribution bus that provides additional breakout terminals for voltage supply (VSUP) and common (COM). These terminals provide a convenient way to distribute power to field devices that require external power. The DO-400 and DO-410 each have: 8 digital output terminals (VOUT) 16 common terminals (COM) 8 power connections to power field devices (VSUP) The DO-401 and DO-403 each have: 16 digital output terminals (VOUT) 8 common terminals (COM) 8 power connections to power field devices (VSUP)

Ordering Information
Compact FieldPoint

NI cFP-DO-400 NI cFP-DO-401 NI cFP-DO-403 NI cFP-DO-410

..........................................................777318-400 ..........................................................777318-401 ..........................................................777318-403 ..........................................................777318-410

Recommended Compact FieldPoint System Products

NI cFP-2020 ..............................................................777317-2020 NI cFP-BP-4 ..................................................................778617-04 NI cFP-CB-1 ..................................................................778618-01 NI PS-4 Power Supply ..................................................778805-90 NI Developer Suite Professional Control Edition..........777906-03
FieldPoint

NI FP-DO-400 NI FP-DO-401 NI FP-DO-403 NI FP-DO-410

............................................................777518-400 ............................................................777518-401 ............................................................777518-403 ............................................................777518-410

Recommended FieldPoint System Products

NI FP-1601 ....................................................................777792-01 NI FP-TB-1 ....................................................................777519-01 NI PS-4 Power Supply ..................................................778586-90 NI Developer Suite Standard Control Edition ............777905-03

BUY ONLINE!
Visit ni.com/info and enter cfpdo400, cfpdo401, cfpdo403, cfpdo410, fpdo400, fpdo401, fpdo403, and/or fpdo410.

C VSUP (Ch 0) Output Circuitry VSUP (Ch 0) + VOUT (Ch 0) COM (Ch 0) VSUP (Ch 1) Output Circuitry VSUP (Ch 1) VOUT (Ch 1) COM (Ch 1) Load Load 5 30 VDC External Power Supply (Optional)

C VSUP (Ch 0) Output Circuitry VOUT (Ch 0) + Load COM (Ch 0) COM (Ch 0) VSUP (Ch 1) Output Circuitry VOUT (Ch 1) Load COM (Ch 1) COM (Ch 1) 530 VDC External Power Supply

VSUP (Ch n) Output Circuitry VSUP (Ch n) VOUT (Ch n) COM (Ch n) Load Output Circuitry

VSUP (Ch n) VOUT (Ch n) Load COM (Ch n) COM (Ch n)

To next channel [c]FP-DO-403

To next channel [c]FP-DO-400/401/410

Figure 1. Wiring Schematics for DO Modules

National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 info@ni.com ni.com

Compact FieldPoint LabVIEW Real-Time Controllers with Ethernet


NI cFP-21xx NEW!
Rugged LabVIEW Real-Time controller 188 MHz processor and up to 128 MB of SDRAM Up to 128 MB of nonvolatile storage and 512 MB removable CompactFlash Ethernet communication for distributed real-time systems Dual redundant 11 to 30 VDC power supply inputs, low power Up to 4 serial ports (3 RS232 and 1 RS485) for communication Industrial certifications, Class I, Div 2, and -40 to 70 C

Operating Systems
Windows 2000/NT/XP LabVIEW Real-Time

Recommended Software
LabVIEW LabVIEW Real-Time Module LabVIEW Datalogging and Supervisory Control Module

Driver Software (included)


Measurement & Automation Explorer OPC server (2.0 compliant)

Controller cFP-2120 cFP-2110 cFP-2100

SDRAM Memory (MB) 128 128 64

Internal Nonvolatile Storage (MB) 128 64 64

Removable CompactFlash 

Ethernet Ports 1 1 1

RS232 Ports 3 2 1

RS485 Ports 1 0 0

Overview
National Instruments Compact FieldPoint is a programmable automation controller (PAC) designed for industrial control applications performing advanced embedded control, data logging, and network connectivity. It combines the packaging, specifications, and reliability of a PLC with the software, flexibility, connectivity, and functionality of a PC. Compact FieldPoint is a reliable platform designed for rugged industrial environments with shock, vibration, and temperature extremes. National Instruments cFP-21xx controllers run LabVIEW Real-Time, providing the functionality, connectivity, and flexibility of National Instruments LabVIEW software on a small industrial platform. The modular I/O architecture with built-in signal conditioning and isolation provides direct connectivity to industrial sensors such as analog voltage, 4 to 20 mA current, thermocouples, RTDs, pressure, strain, flow, pulse-width modulation (PWM), and 24 V digital I/O. You can use NI cFP-21xx controllers in intelligent distributed applications requiring industrial-grade reliability such as process and discrete control systems to open and close valves, run control loops, log data on a centralized or local level, perform real-time simulation and analysis, and communicate over serial and Ethernet networks.

System Basics
A single cFP-21xx controller manages a bank of up to eight Compact FieldPoint I/O modules. The controller mounts securely on a metal backplane that provides the communication bus as well as a solid surface for the Compact FieldPoint I/O modules and controller. The system is modular; select the I/O modules and connector blocks or cabling options best suited for your application. Compact FieldPoint I/O banks have a number of features for industrial operation, including 2,300 V transient overvoltage protection, a wide temperature range for operation in extreme environments, backup power supply connections to protect against primary power failure, and hot-swappable modules to simplify maintenance and minimize downtime. cFP-21xx controllers feature an industrial 188 MHz x86 processor that reliably and deterministically executes your LabVIEW Real-Time applications. Choose from thousands of built-in LabVIEW functions to build your multithreaded embedded system for real-time control, analysis, data logging, and communication. cFP-21xx controllers also offer up to 128 MB of 100 MHz SDRAM and 128 MB of internal nonvolatile storage and a removable CompactFlash slot. All cFP-21xx controllers feature a 10/100 Mb/s Ethernet port for communication over the network (including e-mail) and built-in Web (HTTP) and file servers (FTP). Using the LabVIEW Remote Panel feature, you can automatically publish the front panel graphical user interface (GUI) for your embedded application so that multiple clients can monitor or control it remotely using a Web browser.

LabVIEW Real-Time Controller Interfaces with Ethernet


Compact FieldPoint Real-Time Ethernet Controller Interfaces

NI cFP-2020, NI cFP-2010, NI cFP-2000


Controller Overview
Real-time LabVIEW embedded controllers for intelligent industrial I/O Stand-alone embedded real-time controller or PC-based distributed I/O Ethernet interface Industrial-grade reliability Automatic self-diagnostics Redundant power supply inputs Isolated communication bus to I/O modules RS-232 and RS-485 serial ports for local device control Removable CompactFlash for data logging Class I Div 2 Rated for Hazardous Environments

NEW

Operating Systems
Windows 2000/NT/XP Real-time performance with LabVIEW (page 134)

Recommended Software
LabVIEW LabVIEW Real-Time Module LabVIEW Datalogging and Supervisory Control Module

Other Compatible Software


LabWindows/CVI Measurement Studio Lookout VI Logger

Driver Software (included)


Measurement & Automation Explorer OPC server (2.0 compliant)

Module cFP-2020 cFP-2010 cFP-2000

DRAM Memory 32 MB 32 MB 16 MB

Internal Nonvolite Storage 64 MB 64 MB 32 MB

Removable Compact Flash

Ethernet Ports 1 1 1

RS-232 Serial Ports 3 2 1

RS-485 Serial Ports 1 0 0

System Configurations
A single NI cFP-20xx controller manages a bank of up to eight Compact FieldPoint analog and digital I/O modules, which constitutes a node. The network module securely mounts on a metal backplane that provides a solid mounting surface for the Compact FieldPoint bank and forms the communication bus between the controller module and the I/O modules. You choose the I/O modules and connector block or cabling option that is best suited for your application.
For more details on configuring a Compact FieldPoint system, see page 517.

Overview and Applications


Compact FieldPoint is a programmable automation controller (PAC) designed for industrial control applications performing advanced embedded control, data logging, headless operation, and Ethernet connectivity. It combines the packaging, specifications, and reliability of a PLC with the software, flexibility, connectivity, and functionality of a PC. Compact FieldPoint is our most rugged and reliable platform and is designed for industrial and mobile environments with high shock, vibration, and temperature extremes. Compact FieldPoint banks run LabVIEW Real-Time, providing the functionality, connectivity, and flexibility of LabVIEW on a small, rugged, industrial platform. The modular I/O architecture with built-in signal conditioning and isolation provides direct connectivity to industrial sensors such as analog voltage, 4 to 20 mA current, thermocouple, RTD, pressure, strain, flow, pulse width modulation (PWM), and 24 V digital I/O. Engineers and scientists use the National Instruments cFP-20xx controllers in intelligent distributed applications requiring industrial-grade reliability, such as process and discrete control systems, to open and close valves, run control loops, log data, perform real-time simulation and analysis, and communicate over serial, phone, and Ethernet.

Industrial Control and Distributed I/O

Highly Productive Software


When your application requires powerful functionality and rapid development, the key is flexible software that integrates seamlessly with hardware. LabVIEW is an industry-standard graphical development environment that provides all the tools necessary to create advanced and full-featured measurement and control applications. LabVIEW makes it easy to construct simple or complex applications using an extensive palette of functions and tools from simple analog PID process control loops to highchannel-count hybrid control systems that combine both analog and digital components.

518

National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 info@ni.com ni.com

Ethernet/Serial Interfaces for Compact FieldPoint


NI cFP-180x
Distributed I/O interfaces for Ethernet and RS232 networks 4 or 8-slot Compact FieldPoint distributed Ethernet/serial network interfaces FieldPoint software for rapid distributed I/O access Modbus Support OPC server included Intelligent diagnostics and maintenance Industrial specifications for harsh environments 50 g shock 5 g vibration -40 to 70 C

Operating Systems
Windows 2000/XP

Recommended Software
LabVIEW LabVIEW Datalogging and Supervisory Control Module

Other Compatible Software


LabWindows/CVI Measurement Studio Lookout VI Logger

Driver Software (included)


Measurement & Automation Explorer OPC server (2.0 compliant)

Overview and Distributed Applications


National Instruments cFP-180x interfaces connect four or eight Compact FieldPoint I/O modules to a high-speed Ethernet network or to an RS232 serial port. With up to 100 Mb/s data communication rates and event-driven communications, an NI cFP-180x delivers a high-performance network connection for Compact FieldPoint that is easy to interface with a PC or PAC-like Compact FieldPoint embedded controller. One or more cFP-180x interfaces, connected by standard networking equipment, provide expanded I/O that you can control with a single Compact FieldPoint controller, see Figure 1. You can also build a PC-based distributed I/O and control system by connecting two or more cFP-180x devices to your PC.

Hardware Architecture
A cFP-180x provides an integrated network interface (Ethernet or serial) and a 4 or 8-slot backplane, and it works with the same modules and connector blocks used in other Compact FieldPoint systems.

127 mm (5.00 in.)

441 mm (17.36 in.)

Figure 2. cFP-1808 Mechanical Dimensions

Compact FieldPoint Real-Time Controller


127.0 mm (5.00 in.)

Ethernet

245.9 mm (9.68 in.)

Figure 3. cFP-1804 Mechanical Dimensions

NI cFP-1808 Distributed Network Interfaces

Building Ethernet-Based Distributed I/O Systems


A cFP-180x can communicate with Compact FieldPoint real-time embedded controllers; any Ethernet-based programmable automation controller (PAC); and a Windows computer running LabVIEW, LabWindows/CVI, Measurement Studio, Lookout, or your choice of OPC client application software. Using a cFP-180x, you can rapidly build flexible, modular distributed measurement and automation systems.

Figure 1. Expansion I/O for Compact FieldPoint Embedded Controller with cFP-1808 Network Interfaces

Compact FieldPoint Accessories


Compact FieldPoint Accessories

CompactFlash
The NI cFP-2020 features a slot for removable CompactFlash solid-state nonvolatile memory for storing your downloaded application or for performing embedded data logging. NI offers four sizes of CompactFlash cartridges, ranging from 64 to 512 MB, which are industrially rated to withstand temperatures of -40 to 85 C. 64 MB CompactFlash ......................................................................................778622-64 128 MB CompactFlash ..................................................................................778622-128 256 MB Compact Flash ................................................................................778622-256 512 MB CompactFlash ..................................................................................778622-512

Figure 12. Industrial Rated CompactFlash

RS-232 Cables
The cFP-20xx controllers have the built-in ability to connect to and control external serial devices such as LCD/keypad displays, touch screens, PLCs, bar code scanners, scales, and external I/O. For the RS-232 connector on the front of all cFP-20xx modules, you can use either a standard DB-9 serial cable or, for applications with tight clearances, the right-angle serial connector. The cFP-2010 and cFP-2020 have additional serial ports on the side of the module with RJ-50 connectors. These RS-232 and RS-485 ports can use either a cable with an RJ-50 connector on one end and a DB-9 on the other, or an RJ-50 connection to DIN-rail-mounted connector block with the CB-485A.
Serial Cable Right-Angle Serial Cable S8 Serial Cable S8 Serial Cable S8 Serial Cable S9 Serial Cable CB-485A Cable Length (m) 1 1 2 3 1 1 Connector 1 Right Angle DB-9 RJ-50 RJ-50 RJ-50 RJ-50 RJ-50 Connector 2 DB-9 DB-9 DB-9 DB-9 DB-25 Screw terminals, DIN rail mount Applicable Terminals Front RS-232 Side RS-232/RS-485 Side RS-232/RS-485 Side RS-232/RS-485 Side RS-232/RS-485 Side RS-232/RS-485 Part Number 189284-02 182845-01 182845-02 182845-03 182846-01 778674-01

Ethernet Cables
Twisted-pair, category 5 cable for 10BaseT and 100BaseTX connection connects the FieldPoint FP-1601 and FP-20xx network interface modules to an Ethernet switch or hub. 1 m ....................................................................................................................182219-01 5 m ....................................................................................................................182219-05 10 m ..................................................................................................................182219-10

National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 info@ni.com ni.com

527

Industrial Control and Distributed I/O

Compact FieldPoint Backplanes


Compact FieldPoint Backplanes

NI cFP-BP-4, NI cFP-BP-8
4 and 8-slot backplanes Solid metal construction for rugged installations Panel, DIN rail, and 19 in. rack mounting Local bus for communications and module power Secure screw mounting for I/O and control modules -25 to 60 C operating range

NEW

Back Plane cFP-BP-4 cFP-BP-8

I/O Module Slots 4 8

Standard Mounting Hardware cFP-PM-H horizontal panel mounting bracket cFP-PM-H horizontal panel mounting bracket

Compact FieldPoint and FieldPoint


These backplanes are used with Compact FieldPoint only. Compact FieldPoint is designed for industrial control applications that perform advanced embedded control, data logging, headless operation, and Ethernet connectivity. Compact FieldPoint is our most rugged and reliable platform and is designed for industrial and mobile environments with high shock, vibration, and temperature extremes. FieldPoint is a lower-cost distributed I/O system with a variety of communication options besides Ethernet. It is designed to mount on DIN rails in static applications where the FieldPoint bank is connected to a PC for data collection, analysis, display, and storage.

Overview
National Instruments offers two backplanes for mounting Compact FieldPoint modules the cFP-BP-4 (4 slots) and the cFP-BP-8 (8 slots). Both backplanes, which are constructed of extruded metal with grounding lugs on the bottom, feature screw-down connections for a controller module, four or eight I/O modules, and 37 pin D-Sub connectors for I/O connections. The backplanes all come with a cFP-PM-H horizontal mounting bracket, which provides mounting holes on either side of the backplane so you can mount it to a panel. For other mounting options, you can purchase a vertical panel mount, a DIN rail mount, or a 19 in. rack mount separately.

Industrial Control and Distributed I/O

4 slots = 246 mm (9.68 in.) 8 slots = 441 mm (17.4 in.)


Min. 182 mm (7.18 in.) Cabling Clearance

Min. 165 mm (6.50 in.)

127 mm (5.00 in.)

106 mm (4.18 in.)

Cabling Clearance

Cooling Outline 51 mm (2 in.) All Around

4 slots = 246 mm (9.68 in.) 8 slots = 441 mm (17.4 in.) Cooling Outline 51 mm (2 in.) Cooling Outline 51 mm (2 in.)

Figure 1. Dimensions of the Compact FieldPoint systems with the cFP-BP-4 and cFP-BP-8 backplanes.

522

National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 info@ni.com ni.com

Compact FieldPoint Backplanes


Compact FieldPoint Backplanes

High Shock and Vibration


To withstand high levels of shock and vibration, Compact FieldPoint backplanes are made of extruded metal and provide a rigid mounting surface for the Compact FieldPoint modules. The backplane also provides screw-down connections for the controller module, I/O modules, and connector blocks.

Compact FieldPoint System Configuration


Compact FieldPoint I/O modules mount on either the cFP-BP-4 or cFP-BP-8 backplane. The backplane also contains a controller module, which runs embedded LabVIEW Real-Time and can connect over Ethernet to a PC, to other FieldPoint banks, to Web browsers, or to other Ethernet devices. The Compact FieldPoint backplane also provides a 37-pin D-Sub connector to connect your field signal wiring for each I/O module. You have three options to connect field wiring to this 37-pin D-Sub connector: 1. Using an integrated connector block such as the cFP-CB-1 or cFP-CB-11; 2. Using a cable to an external connector block mounted on a DIN rail; 3. Making your own custom cable.
For more details on configuring your Compact FieldPoint system, please see 517.

Mounting
NI offers four mounting options for Compact FieldPoint backplanes including panel mounting, DIN-rail mounting, and 19 in. rack mounting.
Mounting Option cFP-PM-H Description Panel mount with bolt holes at the sides of the backplane. (included with all backplane) Panel mount with bolt holes at the top and bottom of the backplane 19 in. rack mount. Features captive screws for easy mounting and cutouts for running grounding cables DIN rail clip for cFP-BP-4 Number Needed to Mount cFP-BP-4 1 Number Needed to Mount cFP-BP-8 1

cFP-PM-V cFP-RM-8

1 1

1 1

DIN rail mounting clip

2*

Ordering Information
NI cFP-BP-4 ..................................................................778617-04 NI cFP-BP-8 ..................................................................778617-08
Recommended Compact FieldPoint System Products

* DIN rail mounting is not recommended for the cFP-BP-8

NI cFP-2020 ..............................................................777317-2020 NI cFP-CB-1 ..................................................................778618-01 NI PS-5 Power Supply ..................................................778805-90 NI Developer Suite Professional Control Edition..........777906-03

BUY ONLINE!
Visit ni.com/info and enter cfppb4, and/or cfppb8.

National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 info@ni.com ni.com

523

Industrial Control and Distributed I/O

Compact FieldPoint I/O Connectivity Accessories


Compact FieldPoint I/O Connectivity Accessories

Flexible I/O Connectivity


The Compact FieldPoint backplane provides standard 37-pin D-Sub connectors for the signals from the I/O modules. This provides you the flexibility to choose the connectivity method that works best for your application. You have three options to connect field wiring to the 37-pin D-Sub connectors: 1. Using an integrated connector block like the cFP-CB-1, cFP-CB-3, or cFP-CB-11 2. Using a cable to an external connector block mounted on a DIN rail 3. Making your own custom cable.
Figure 1. cFP-CB-1 General-Purpose Connector Block

Integrated Connector Blocks


The most secure and compact connectivity option is to use the integrated connector blocks. We offer three connector blocks the cFP-CB-1, the cFP-CB-3, and the cFP-CB-11.

cFP-CB-1 (See Figure 1)


The cFP-CB-1 is a general-purpose connector block suitable for any I/O module. With 36 terminals, the connector block simplifies wiring by eliminating the need to connect more than one wire to a terminal. The cFP-CB-1 also features both a built-in strain relief bar and a separate wire tie connector, making it easy to create secure wiring setups for high shock and vibration applications. Although both the cFP-CB-1 and the cFP-CB-3 feature a built-in thermistor for cold-junction compensation, we recommend using the cFP-CB-3 when measuring thermocouples.

Figure 2. cFP-CB-3 Isothermal Connector Block for Thermocouple Measurement

cFP-CB-3 (See Figure 2)


The cFP-CB-3 connector block is designed for use with the cFP-TC-120 module. The cFP-CB-3 uses isothermal construction to minimize thermal gradients on the I/O terminals. This increases the accuracy of the thermistor that is used for cold-junction compensation. The cFP-CB-3 also features both a built-in strain relief bar and a separate wire tie connector, making it easy to create secure wiring setups for high shock and vibration applications.

Figure 3. cFP-CB-11 Low-Profile Connector Block

cFP-CB-11 (See Figure 3) Industrial Control and Distributed I/O


The cFP-CB-11 is a low-profile, general-purpose connector block suitable for any I/O module except the thermocouple module. These connector blocks feature a side exit for the wiring, making them a good fit for applications with limited front clearance. Because the connector blocks are smaller, the cFP-CB-11 is best suited for applications that use small-gauge wire or that use only a few channels.
Connector Block cFP-CB-1 cFP-CB-3 cFP-CB-11 Number of Screw Terminals 36 18 37 High Shock and Vibration Voltage Limit 250 V 250 V 24 V

Built-in CJC

Applications General purpose Isothermal for thermocouple Low wiring density and low clearance

Part Number 778618-01 778618-03 778618-11

524

National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 info@ni.com ni.com

Compact FieldPoint Accessories

Figure 1. cFP-PM-V, Vertical-Mounting Kit

Figure 2. cFP-PM-H, Horizontal-Mounting Kit

Figure 3. cFP-RM-8, Rack-Mounting Kit

Figure 4. PS-5 Power Supply (24 VDC)

Figure 5. Panel and DIN Rail-Mounting Kits

Mounting Options (see figures 1, 2, and 3)


NI offers four mounting options for Compact FieldPoint, including panel mounting, DIN rail mounting, and 19 in. rack mounting.
Mounting Option cFP-PM-H cFP-PM-V cFP-RM-8 DIN Rail-Mounting Clip
1DIN

Description Panel mount with bolt holes at the sides of the backplane (included with all backplane) Panel mount with bolt holes at the top and bottom of the backplane 19 in. rack mount; features captive screws for easy mounting and cutouts for running grounding cables DIN rail clip for cFP-BP-4

Quantity Needed to Mount cFP-BP-4 1 1 1 1

Quantity Needed to Mount cFP-BP-8 1 1 1 21

Part Number 778616-01 778688-01 778615-01 778614-01

rail mounting is not recommended for the cFP-BP-8.

Power Supplies (see Figure 4)


National Instruments offers five DC supplies for Compact FieldPoint systems. You connect the power supply output to the Compact FieldPoint controller, which regulates, filters, and distributes power to the bank of up to eight I/O modules that it controls. All five power supplies can power an entire bank of Compact FieldPoint I/O modules. The PS-5 mounts on a DIN rail and is recommended for most Compact FieldPoint installations.
Model PS-1 PS-2 Output Voltage (VDC) 20 24 Output Current (A) 0.8 0.8 Input Voltage 120 VDC P = 1 U.S. 120/Japan 100 VAC 2 Swiss 220 VAC, 3 Australian 4 Universal Euro 240 VAC 5 North American 240 VAC 6 United Kingdom 240 VAC Same as PS-2 90 to 260 VAC 50/60 Hz 90 to 260 VAC 50/60 Hz Part Number 777567-01 777584-0P

PS-3 PS-4 PS-5

13.8 24 24

4 0.625 5

777585-0P 778586-90 778805-90

Power connects to the cFP-21xx modules, which regulate, filter, and distribute to attached I/O modules.

Stand-Alone Controller-Mounting Accessories (see Figure 5)


National Instruments offers options for mounting stand-alone Compact FieldPoint controllers. These accessories support applications for redundant controllers without redundant I/O. The panel and DIN rail-mounting kits also provide mounting options for a stand-alone Compact FieldPoint real-time controller running LabVIEW Real-Time software. Controller-mounting options include panel and DIN rail-mounting.
Model Panel DIN rail Description Panel-mounting kit for stand-alone controllers DIN rail-mounting kit for stand-alone controllers Part Number 779549-01 779552-01

BUY NOW!
For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S.) or go to ni.com/compactfieldpoint.

También podría gustarte