FEATURES
FULL RANGE OF ATTACHMENTS Wide range of bolt-on system expansion attachments, factory designed and tested UL 2200 UL 2200 Listed configuration available ENCLOSURES (Optional) Weather protective and sound attenuated SINGLE-SOURCE SUPPLIER Complete systems designed at Caterpillar ISO9001 certified facilities Certified Prototype Tested with torsional analysis WORLDWIDE PRODUCT SUPPORT Worldwide parts availability through the Caterpillar dealer network With over 1,200 dealer outlets operating in 166 countries, youre never far from the Caterpillar part you need. 99.5% of parts orders filled within 48 hours. The best product support record in the industry. Caterpillar dealer service technicians are trained to service every aspect of your electric power generation system. Preventive maintenance agreements The Cat Scheduled Oil Sampling (SOSSM) program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products
CAT 3412 STA DIESEL ENGINE Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight CAT SR4B GENERATOR Designed to match performance and output characteristics of Caterpillar diesel engines Optimum winding pitch for minimum total harmonic distortion and maximum efficiency Segregated AC/DC, low voltage accessory box provides single point access to accessory connections UL 1446 Recognized Class F available for UL 2200 packaged generator set CAT CONTROL PANELS Three levels of controls, designed to meet individual customer needs: EMCP II provides digital monitoring, metering, and protection EMCP II provides EMCP II features along with full-featured power metering and protective relaying Switchgear conversion provides easy interface for remote switchgear
W H E R E
T H E
W O R L D
T U R N S
F O R
P O W E R
S T A N D B Y P R I M E 6 0 H z
8 0 0 7 2 5
e k W e k W
Exhaust
Fuel
Generator
Primary fuel filter/water separator Secondary fuel filter Fuel priming pump Flexible fuel lines Permanent magnet class H insulation class F temperature rise [130 C standby/105 C prime] Reactive droop kit 2:1 Volts/Hz AVR Extension box Electronic EMCP II Lubricating oil and filter Oil drain line with valves Fumes disposal Formed steel base Linear vibration isolators between base and engine-generator 45 amp charging alternator Energized To Run (ETR) fuel shutoff solenoid 24 volt starting motor Batteries with rack and cables Battery disconnect switch
20 dBA muffler and ANSI weld flanges 25 dBA muffler and ANSI weld flanges 30 dBA muffler and ANSI weld flanges Elbow kit, through-wall installation kit Manifold and turbocharger guards All mufflers have side/end inlet options Manual transfer pump (3) Automatic transfer systems to choose from Low fuel level alarm and shutdown Self excited Digital Voltage Regulator Digital Voltage Regulator with KVAR/PF control Anti-condensation space heater Oversize and premium generators Circuit breaker, UL listed, 3-pole with shunt trip Multiple breaker capability Electronic load sharing Switchgear conversion EMCP II Local alarm and remote annunciator modules Manual sump pump Integral fuel tank base Sub base fuel tank Wide base Skid base Heavy-duty starting system Integral 5 and 10 amp battery chargers Oversize batteries Ether starting aid Enclosures sound attenuated, weather protective Automatic transfer switches Floor standing circuit breakers
Starting/ Charging
Other
SPECIFICATIONS
CAT SR4B GENERATOR
Frame size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 597 Type . . . . . . . . . Permanent magnet, static regulated, brushless Construction . . . . . . . . . . . . . . . . . . Single bearing, close coupled Three phase . . . . . . . . . . . . . . . . . . . . . . . . . 12 lead reconnectable Insulation . . . . . . Class H with tropicalization and antiabrasion IP rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Drip proof IP22 Alignment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pilot shaft Overspeed capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150% Wave form. . . . . . . . . . . . . . . . . . . . . . . . . . Less than 5% deviation Paralleling capability . . . . . . . . . . . . . . . . With droop transformer Voltage regulator . . . . . 3-phase sensing with 2 Volts-per-Hertz Voltage regulation . . . . . . . . . . . . . . Less than 1/2% (steady state) Less than 1% (no load to full load) TIF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 50 THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 5%
CAT ENGINE
3412 STA, V-12, 4-stroke-cycle watercooled diesel Bore mm (in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 (5.4) Stroke mm (in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 (6.0) Displacement L (cu in) . . . . . . . . . . . . . . . . . . . . . . . . 27.0 (1649) Compression ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.0:1 Aspiration . . . . . . . . . . . . . . . . . . . . . . . Turbocharged, Aftercooled Fuel system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical pump Governor type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic
S T A N D B Y P R I M E 6 0 H z
8 0 0 7 2 5
e k W e k W
TECHNICAL DATA
Generator Set 1800 rpm/60 Hz Package Performance Power rating Power rating @ 0.8 PF Fuel Consumption 100% load with fan 75% load with fan 50% load with fan Cooling System Ambient air temperature Air flow restriction (system) Air flow (maximum @ rated speed for standard radiator arrangement) Engine coolant capacity with radiator Engine coolant capacity without radiator Exhaust System Combustion air inlet flow rate Exhaust stack gas temperature Exhaust gas flow rate Exhaust flange size (internal diameter) Exhaust system backpressure (maximum allowable) Heat Rejection Heat rejection to coolant (total) Heat rejection to exhaust (total) Heat rejection to atmosphere from engine Heat rejection to atmosphere from generator Alternator* Motor starting capability @ 30% voltage dip Frame Temperature rise Lube System Refill volume with filter change for standard sump ekW kVA L/hr L/hr L/hr Deg C kPa m3/min L L m3/min Deg C m3/min mm kPa kW kW kW kW kVA Deg C L Qts 139 Gal/hr Gal/hr Gal/hr Deg F in water cfm Gal Gal cfm Deg F cfm in in water Btu/min Btu/min Btu/min Btu/min 221.8 165.7 115.7 52 0.12 1695 133 58.6 69.6 518 195.1 203 6.7 508 855 131 40.15 2407 597 130 147 139 Standby DM0636-02 800 1000 58.6 43.8 30.6 126 0.48 59,894 35.1 15.5 2458 964 6889 8 26.9 28,890 48,624 7450 2283 198.8 150.6 106.5 50 0.12 1695 133 58.6 63.0 512 175.2 203 6.7 457 764 108 35.84 2407 597 105 147 Prime DM0633-02 725 906 52.5 39.8 28.1 122 0.48 59,894 35.1 15.5 2225 953 6186 8 26.9 25,990 43,449 6142 2038
*UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics.
S T A N D B Y P R I M E 6 0 H z
8 0 0 7 2 5
e k W e k W
1812.4 [71.35]
Fumes Disposal Tube Oil Level Gauge Oil Filler Fuel Priming Pump
1938.0 [76.30]
1939.6 [76.36]
Customer Mounting Holes Primary Fuel Filter 32.0 [1.26] Removal Distance Fuel Supply 1/2-14 NPTF Fuel Return 1/2-14 NPTF Fuel Filter 27.9 [1.10] Removal Distance
Customer Mounting Holes Oil Filter 27.9 [1.10] Removal Distance Oil Drain Customer Mounting Holes
Package Dimensions Length Width Radiator Height Control Panel Height Shipping Weight 4485.0 mm 1812.4 mm 1939.6 mm 1938.0 mm 6762 kg 176.57 in 71.35 in 76.36 in 76.30 in 14,910 lb Note: General configuration not to be used for installation. See general dimension drawings for detail (Drawing #186-3619).
www.CAT-ElectricPower.com TMI Reference No.: DM0636-02, DM0633-02 U.S. sourced LEHX9481-03 (11-00) 2000 Caterpillar All rights reserved. Printed in U.S.A. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication.