3RU1136-4HB0
OVERLOAD RELAY, 40...50 A, 1NO+1NC, SIZE S2, CLASS 10, FOR CONTACTOR MOUNTING
F 100 CLASS 10
3RU1136-4HB0 Page 1/ 5
03/09/2012
Type of assignement type of protection Size of overload relay Size of the contactor / can be combined / company-specific Protection against electrical shock
Main circuit:
Number of poles / for main current circuit Operating voltage / at AC-3 / rated value maximum Service power / at AC-3 at 400 V Adjustable response current of the current-dependent overload release A 40 50 kW 22 V 690 3
Auxiliary circuit:
Contact reliability / of the auxiliary contacts Number of NC contacts Number of NO contacts Number of change-over switches Operating current / of the auxiliary contacts / at AC-15 at 24 V at 110 V at 120 V at 125 V at 230 V at 400 V Operating current / of the auxiliary contacts / at DC-13 at 24 V at 110 V at 125 V at 220 V A A A A 1 0.22 0.22 0.11 A A A A A A 3 3 3 3 2 1 acceptability for PLC control (17 V, 5 mA) 1 1 0
Short-circuit:
Design of the fuse link / for short-circuit protection of the auxiliary switch / required fuse gL/gG: 6 A, quick: 10 A
Installation/mounting/dimensions:
Built in orientation with vertical mounting surface +/-135 rotatable, with vertical mounting surface +/- 45 tiltable to the front and back direct mounting
Type of mounting
3RU1136-4HB0 Page 2/ 5
03/09/2012
Height Width Depth Distance, to be maintained, to the ranks assembly upwards downwards forwards backwards sidewards Distance, to be maintained, to earthed part upwards downwards forwards backwards sidewards Distance, to be maintained, conductive elements upwards downwards forwards backwards sidewards
mm mm mm
105 55 118
mm mm mm mm mm
0 0 0 0 0
mm mm mm mm mm
0 0 0 0 6
mm mm mm mm mm
0 0 0 0 6
Connection type:
Product function removable terminal for auxiliary and control circuit Design of the electrical connection for main current circuit for auxiliary and control current circuit Type of the connectable conductor cross-section for main contacts solid stranded finely stranded with conductor end processing for auxiliary contacts solid finely stranded with conductor end processing for AWG conductors for main contacts 2x (18 ... 3), 1x (18 ... 1) 2x (0.5 ... 1.5 mm), 2x (0.75 ... 2.5 mm) 2x (0.5 ... 1.5 mm), 2x (0.75 ... 2.5 mm) 2x (0.75 ... 16 mm), 0.75 ... 25 mm 2x (0.75 ... 16 mm) 2x (0.75 ... 25 mm), 0.75 ... 35 mm screw-type terminals screw-type terminals No
3RU1136-4HB0 Page 3/ 5
03/09/2012
for auxiliary contacts Conductor cross section that can be connected for main contacts solid stranded stranded wire with conductor end processing for auxiliary contact solid stranded wire with conductor end processing AWG number / as coded connectable conductor cross-section for main contacts / minimum for auxiliary contact mm mm mm mm mm
0.75 16 0.75 35
0.75 25
0.5 2.5
0.5 2.5
18 20 14
Certificates/approvals:
Verification of suitability CSA / UL / CC / GL / LRS / BV / DNV / RMRS / RINA / PRS / ABS Yes For use in hazardous locations DEKRA EXAM, DMT Test Certificates
ROSTEST
Manufacturer
Shipping Approval
Shipping Approval
other Manufacturer
Further information:
Information- and Downloadcenter (Catalogs, Brochures,) http://www.siemens.com/industrial-controls/catalogs Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall CAx-Online-Generator http://www.siemens.com/cax Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/3RU1136-4HB0/all
3RU1136-4HB0 Page 4/ 5
03/09/2012
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RU1136-4HB0
last change:
Mar 5, 2012