Está en la página 1de 6

EN 1999-1-1 DK NA:2007

National Annex to Eurocode 9: Design of aluminium structures Part 1-1: General rules and rules for buildings
_______________________________________________________________________

Foreword
In connection with the incorporation of Eurocodes into Danish building legislation to replace the Danish structural codes of practice, this National Annex was prepared in 2006-2007 to implement Eurocode 9 in Denmark.

Scope
This National Annex lays down the conditions for the implementation of the Eurocode.

Contents
This National Annex specifies the national choices prescribed in Denmark. The national choices may be in the form of nationally applicable values, an option between methods given in the Eurocode, or the addition of supplementary guidance. This National Annex addresses: Clauses where national choices have been made; All clauses where national choices have been possible; Bibliography: Overview of all National Annexes prepared.

Page 1 of 6
EN 1999-1-1 DK NA, 2007-11-14, 2nd edition

Clauses where national choices have been made


Clause 6.1.3(1) National choice The following values should be used: M1=1,23 M2=1,353 The factor 3 takes account of the inspection level of the product. The relaxed inspection level is not used. Tightened inspection level: 3 = 0,95 Normal inspection level: 3 = 1,00 The partial factors are determined in accordance with the National Annex to EN 1990, Annex F, where M = 1 2 3 4. 1 takes into account the type of failure 2 takes into account the uncertainty related to the design model 3 takes into account the extent of inspection 4 takes into account the variation of the strength parameter or resistance. When determining 1 the following types of failure have been assumed: M1: Warning of failure without spare resistance M2: No warning of failure For accidental and seismic design situations the following values should be used: Mi=1,0 for all i's in EN 1999-1-x 7.2.1(1) For beams, the following values of the maximum deflection (w3 in EN 1990, Figure A1.1) due to one variable action without allowance for impact, if any, may serve as guidance as to what may be regarded as acceptable deflections: building floors roofs and external walls where l is the span of simply supported and continuous beams, or twice the projection of cantilevered structures. l/400 l/200

The values apply both to main and secondary elements, but only the deflection of the element considered should be used in the assessment.

Page 2 of 6
EN 1999-1-1 DK NA, 2007-11-14, 2nd edition

For secondary thin-plate structures in the form of uninsulated roof sheeting and for facade sheeting the deflection due to permanent and variable actions should not exceed l/90. For roof sheeting with external insulation and roofing felt the deflection due to permanent and variable actions should not exceed: l/150 30 mm l/200 7.2.2(1) for for for l < 4500 mm 4500 mm < l < 6000 mm 6000 mm < l

For columns, the following values of the maximum deflection of the column head due to one variable action may serve as guidance to what may be regarded as acceptable deflections: frames in buildings without cranes columns in single-storey skeleton structures columns in multi-storey skeleton structures, for each storey for the total height where h he h/150 h/300 h/300 he /500

is the height of the individual column is the total height of the building. 1,353 1,353 1,353 1,353 1,103 3,03 1,103 1,103 1,003 1,203 1,23 2,23 1,23 2,23

8.1.1(2)

The following values should be used: M2 = Mp = Mw = M3 = (ultimate limit) M3 = (serviceability, fatigue see 8.5.9.3) Ma = M4 = M5 = M6,ser = M7 = The following values should be used: Mo,c = Mu,c = The following values should be used: M2,co = M2,cu = The following values should be used:

C3.4.1(2)

C3.4.1(3)

C3.4.1(2)

Page 3 of 6
EN 1999-1-1 DK NA, 2007-11-14, 2nd edition

Mp,co = Mp,cu =
K.3(1)

1,353 2,23

The recommended Method a should be used. Consequently, no limiting value for plastic strain is given for the use of Method c.

Page 4 of 6
EN 1999-1-1 DK NA, 2007-11-14, 2nd edition

Overview of possible national choices


The list below identifies the clauses where national choices are possible and the applicable/not applicable informative annexes. Furthermore, this National Annex refers to additional (non-conflicting) information that may be of assistance to the user of the Eurocode. Clauses 1.1.2(1) 2.1.2(3) 3.2.1(1) 3.2.2(1) 3.2.2(2) 3.2.3.1(1) 3.3.2.1(3) 3.3.2.2(1) 5.2.1(3) 5.3.2(3) 5.3.4(3) 6.1.3(1) 6.2.1(5) 6.8.1(4) 7.1(4) 7.2.1(1) 7.2.2(1) 7.2.3(1) 8.1.1(2) A(6) (Table A.1) C.3.4.1(2) C.3.4.1(3) C.3.4.1(4) K.1(1) K.3(1) Comment No change No change No change No change No change No change No change No change No change No change No change Nationally applicable values No change No change No change Additional information Additional information No change Nationally applicable values No change Nationally applicable values Nationally applicable values Nationally applicable values No change Choice between methods

Page 5 of 6
EN 1999-1-1 DK NA, 2007-11-14, 2nd edition

Bibliography
List of all National Annexes
EN 1990 DK NA:2007 EN 1991-1-1 DK NA:2007 EN 1991-1-2 DK NA:2007 EN 1991-1-3 DK NA:2007 EN 1991-1-4 DK NA:2007 EN 1991-1-5 DK NA:2007 EN 1991-1-6 DK NA:2007 EN 1991-1-7 DK NA:2007 EN 1992-1-1 DK NA:2007 EN 1992-1-2 DK NA:2007 EN 1993-1-1 DK NA:2007 EN 1993-1-2 DK NA:2007 EN 1993-1-3 DK NA:2007 EN 1993-1-4 DK NA:2007 EN 1993-1-5 DK NA:2007 EN 1993-1-6 DK NA:2007 EN 1993-1-7 DK NA:2007 EN 1993-1-8 DK NA:2007 EN 1993-1-9 DK NA:2007 EN 1993-1-10 DK NA:2007 EN 1994-1-1 DK NA:2007 EN 1994-1-2 DK NA:2007 EN 1995-1-1 DK NA:2007 EN 1995-1-2 DK NA:2007 EN 1996-1-1 DK NA:2007 EN 1996-1-2 DK NA:2007 EN 1996-2 DK NA:2007 EN 1997-1 DK NA:2007 EN 1999-1-1 DK NA:2007 EN 1999-1-2 DK NA:2007 EN 1999-1-3 DK NA:2007 National Annex to Eurocode 0 Basis of structural design National Annex to Eurocode 1: Actions on structures Part 1-1: General actions Densities, selfweight, imposed loads for buildings National Annex to Eurocode 1: Actions on structures Part 1-2: General actions Actions on structures exposed to fire National Annex to Eurocode 1: Actions on structures Part 1-3: General actions Snow loads National Annex to Eurocode 1: Actions on structures Part 1-4: General actions Wind actions National Annex to Eurocode 1: Actions on structures Part 1-5: General actions Thermal actions National Annex to Eurocode 1: Actions on structures Part 1-6: General actions Actions during execution National Annex to Eurocode 1: Actions on structures Part 1-7: General actions Accidental actions National Annex to Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings National Annex to Eurocode 2: Design of concrete structures - Part 1-2: General rules Structural fire design National Annex to Eurocode 3: Design of steel structures - Part 1-1: General rules and rules for buildings National Annex to Eurocode 3: Design of steel structures - Part 1-2: General rules Structural fire design National Annex to Eurocode 3: Design of steel structures - Part 1-3: General rules - Supplementary rules for cold-formed members and sheeting National Annex to Eurocode 3: Design of steel structures - Part 1-4: General rules - Supplementary rules for stainless steels National Annex to Eurocode 3: Design of steel structures - Part 1-5: Plated structural elements National Annex to Eurocode 3: Design of steel structures - Part 1-6: Strength and stability of shell structures National Annex to Eurocode 3: Design of steel structures - Part 1-7: Plated structures subject to out of plane loading National Annex to Eurocode 3: Design of steel structures - Part 1-8: Joints National Annex to Eurocode 3: Design of steel structures Part 1-9: Fatigue National Annex to Eurocode 3: Design of steel structures - Part 1-10: Material toughness and throughthickness properties National Annex to Eurocode 4: Design of composite steel and concrete structures - Part 1-1: General rules and rules for buildings National Annex to Eurocode 4: Design of composite steel and concrete structures - Part 1-2: General rules Structural fire design National Annex to Eurocode 5: Design of timber structures - Part 1-1: General - Common rules and rules for buildings National Annex to Eurocode 5: Design of timber structures - Part 1-2: General Structural fire design National Annex to Eurocode 6: Design of masonry structures - Part 1-1: General rules for reinforced and unreinforced masonry structures National Annex to Eurocode 6: Design of masonry structures - Part 1-2: General rules Structural fire design National Annex to Eurocode 6: Design of masonry structures - Part 2: Design considerations, selection of materials and execution of masonry National Annex to Eurocode 7: Geotechnical design - Part 1: General rules National Annex to Eurocode 9: Design of aluminium structures - Part 1-1: General rules National Annex to Eurocode 9: Design of aluminium structures Part 1-2: Structural fire design National Annex to Eurocode 9: Design of aluminium structures Part 1-3: Fatigue

Page 6 of 6
EN 1999-1-1 DK NA, 2007-11-14, 2nd edition

También podría gustarte