General Spec.
Item Ambient conditions Spec. 1040 1050 3090%RH Less than 1000m Commercial frequency, AC2000V 1min. In compliance with JEC210, IEEE472 Remarks To be installed in air-conditioned room. No condensation No condensation No condensation
Withstand voltage
Ambient temperature (under operation) Ambient temperature (under storage) Humidity Altitude Withstand voltage Impulse withstand voltage
Advantage of MEC700AVR
Realize 5msec sampling time with 32-bit RISC
140
190
processor.
Better space factor in a cubicle by downsizing to be
an integrated unit.
Dual system configuration using duplex cable
CONT STDBY EXCL LOCK SHE SME SLE WDT CLK FLASH AVR MVR PSS
LED indicators
DI
connections of 2 units.
315 Correction by Q axis reactance for -PSS and stan
ETHER-1 ETHER-2
side. All connector has different shape for preventing from wrong connection.
POWER ON OFF
Earth terminal
FRONT VIEW
Not used
SIDE VIEW
DUAL
SYN
AO
190
24PS
VTCT
SPIN
AIAO
BOTTOM VIEW
AVR cubicle
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
http://Global.MitsubishiElectric.com
Safety Precautions Improper use of products can cause severe injury or death and may result in damage to product and other property. Please read instruction manual before installing or using product.
The digital automatic voltage regulator (D-AVR) is indispensible for operations. It regulates synchronous generator voltage, and is therefore required to have superior reliability, easy operation and maintenance. D-AVR MEC700 is developed and produced which achieve easier maintenance and environmental load-reducing.
Advantage
Item Spec. At generator no-load At generator on-load 10110% of rated voltage 95105% of rated voltage Remarks Auto. Voltage setting range (90R) Manual voltage setting range (70E) Voltage oset error Voltage detection accuracy CPU sampling time Power source Interface 1% or less 0.5% or less 5msec For control DC24V5%, 35W or less For ring pulse DC24V/48V5% DI32 points AI6 points 3 phase input VT3 phase Firing pulse output 6 points 4parallels thyristor are available (around 5000A) Speed inputElectromagnetic pick up, for -PSS Ethernet 2 channels Trend function Event history Self-diagnosis functions Analog 16pointsdigital 16points 10sec. from a trigger, 5times reservable. 4096 cases Basic hardware and software Analog input Firing pulse control WDT, Clock loss VT/CT zero phase unbalance detection Synchronous signal loss, loss of pulse DO32 points AO8 points CT3 phase or single phase 10V 240MHz
Performance
10% of rated voltage at generator no-load to 120% of eld voltage at generator rated load
Operation Maintenance
Maintenance tool can monitor, operate, parameter set and trend graph display at fault condition. Allows quick detection of faulty positions with LED display, maintenance tool alarm system and CPU fault information display. High density functions are realized by using box-type module and functional software. When dual system is consisted, On-line replacing is applicable. Moreover interface connectors are selected different shape to prevent wrong connection. High space efficiency and easier maintenance with high-density and downsizing by use of functional software. In order to support periodical inspections, Software and a maintenance tool for tests are provided.
Max. 10 parallels with connecting pulse amplier units. (Optional) Optional card is necessary. Display in a maintenance tool CSV data is available Display in a maintenance tool
Function
Details Constant voltage control Constant eld control Minimum/Under excitation limit Over-excitation limit Power system stabilizer P-PSS f - PSS (with Q-axis reactance compensate) -PSS (optional card is necessary) with torsional lter with torsional lter
Environmental load-reducing
Environmental load- reducing by downsizing and less power.
Control function
Standard function
Additional functions
PSS
AQR
Reactive power regulation Power factor regulation V/Hz limit control Stator current limit Cross current compensation Line (reactance, resistance) voltage drop compensation SFC, Electric brake eld control, Line charge
System configuration
APFR
AVR cubicle
VT Aux. VT/CT CT
DI 3phase AI
DO
AC DC
Excitation transformer
Maintenance tool
Connector terminal block Maintenance tool converter Shunt converter Field circuit breaker AC
Main screen
G
Field winding Field discharge circuit