Upon completion of this course, you will be able to:


Master data collection method of DT Master how to use GENEX Probe to collect drive test data

www.huawei.com

2
Huawei confidential, 2007-10

Contents

GENEX Overview GENEX Probe General Workflow

Using Probe for HSDPA / HSUPA DT Data Collection


Other Features Case Study

www.huawei.com

3
Huawei confidential, 2007-10

Huawei GENEX Family


GENEX Nastar is a platform for monitoring and optimizing the performance of GSM/CDMA/WCDMA wireless networks

GENEX Nastar Network Performance Analysis System

GENEX Probe GENEX Assistant Test & Post-Process Tools


Downlink + Uplink

The GENEX Probe, network optimization and drive test data collection system, is an air interface test tool for WCDMA/HSDPA/HSUPA/GSM/GP RS networks. GENEX Assistant is a professional wireless test data post-processing software system.

RNC

GENEX U-Net Radio Network Planning Tool


4

GENEX U-Net is a radio planning tool that fully supports the technologies of GSM,GPRS-EDGE, CDMA IS95, WCDMA/UMTS/HSDPA/HSUPA, CDMA 2000/1xRTT/1xEVDO, and TD-SCDMA wireless networks.

www.huawei.com

4
Huawei confidential, 2007-10

Whole Flow Overview

GENEX covers the network lifecycle

Radio Network Planning Tool

Air Interface Test Tool and PostProcessing Tool Network Performance Analysis Tool

Make full use of 2G resources

www.huawei.com

5
Huawei confidential, 2007-10

GENEX Partners in The World


Applied in the Huawei 2G and 3G planning and optimization projects Covers more than forty countries, including commercial and pilot offices Assists the renowned operators in establishing and optimizing the network with high quality. The network operators include but not limited to: China Mobile, China Unicom, China Telecom, China Netcom, Vodafone, PBTL, T-Mobile, Orange, CellPlus, PCCW(Sunday), Telecom, eMobile. Aims at consistently providing the customers with professional and high-level solutions for network planning and optimization. Employed by network operators and designing institutes all over 26 provinces and municipalities Integrates the experiences of renowned operators, advancing with customers hand by hand.

www.huawei.com

6
Huawei confidential, 2007-10

Contents

GENEX Overview GENEX Probe General Workflow

Using Probe for HSDPA / HSUPA DT Data Collection


Other Features Case Study

www.huawei.com

7
Huawei confidential, 2007-10

GENEX Probe drive test system


*Support WCDMA 1800/1900/2100M

GARMIN Series GPS

Huawei Dual Mode Mobile(U626/U636)

Qualcomm TM6250/ 6275

AT Command Huawei WCDMA/HSDPA Data card Supported Mobile

Trimble Series GPS

DTI Scanner (Built-in GPS)

Anritsu Scanner

Equipment Composition Physical connection


support multi UE carry out different tests simultaneously
8

Equipment bag

easy to carry and suitable to be used in the car 8

www.huawei.com

Huawei confidential, 2007-10

DT Operation Flow
1. Probe Installation. HSDPA test need Probe version 1.3 or above; HSUPA test need Probe version 1.4 or above. 2. Plug Probe dongle. 3. Connect Hardware device to the laptop. 4. Hardware configuration. 5. System Configuration. Set Log mask. 6. Test Plan Configuration. 7. Import engineering parameters, open Map window and import the related mapinfo file. 8. Open the parameter widows you want to observe, such as RSCP and Ec/Io in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message, NAS Message, etc. 9. Start Test, start recording. 10. After the test finished, press "Stop Test button. Notes: If you don't use "Test Plan" to start test automatically, please "Start Test first, then start to make call test.
9

www.huawei.com

9
Huawei confidential, 2007-10

Probe Interface

hardware & system configuration

Control & parameter items

HSDPA parameters

Parameter observation area

HSUPA parameters RRC&NAS Messages

Throughput

PS service statistics

10

www.huawei.com

10
Huawei confidential, 2007-10

Configuration Before Test


Hardware configuration
Terminals in the following list can support HSDPA test are: Huawei E620 data card , QUALCOMM TM6275 and QUALCOMM TM6280. Huawei E220 and E6280 will support HSUPA soon.

PS domain test must set Modem port.

11

www.huawei.com

11
Huawei confidential, 2007-10

System Configuration Before Test


Logmask setting
We can make UE report the data we need through Logmask setting.

12

www.huawei.com

12
Huawei confidential, 2007-10

System Configuration Before Test


Event setting
We can define the event we need throuth Event setting.

13

www.huawei.com

13
Huawei confidential, 2007-10

System Configuration Before Test


Alarm setting
We can define the alarm event we need through Alarm setting.

14

www.huawei.com

14
Huawei confidential, 2007-10

System Configuration Before Test


Other setting
We can set the Time Record Mode for a Log Packet, GPS synchronization Mode, DialUp Property for Data Service, Display Filter for Log Data, Replay Mode for Event and Parameters for DTI Scanner which we need through other setting.

15

www.huawei.com

15
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Test Plan Configuration
Control each device's behavior by selecting Test Plan items and setting property parameters of each test items. Set the Test Plan respectively for each device (UE/Scanner).
4. Set Test Property 1. Select Test Device

2. Add Test Scenario

3. Add Test Item

16

www.huawei.com

16
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for DTI Scanner

1. Select Test Item

2. Set Item Property

17

www.huawei.com

17
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for Anritsu Scanner

1. Select Test Item

2. Set Test Property

18

www.huawei.com

18
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for Anritsu ScannerCont. Unspecified base station measurement
Set the common properties of test

Items in the unspecified base station measurement

19

www.huawei.com

19
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for Anritsu ScannerCont. Unspecified base station measurement
Set the common properties of test

Items in the Conditions base station

20

www.huawei.com

20
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for Anritsu ScannerCont. Unspecified base station measurement
Set the common properties of test Items in the CH limits

21

www.huawei.com

21
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for Anritsu ScannerCont. Unspecified base station measurement
Set the common properties of test

Elements in the MeasureChannel Dialog Box

22

www.huawei.com

22
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for Anritsu ScannerCont. Specified base station measurement
Set the specified properties of test

23

www.huawei.com

23
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
1. Voice call

24

Suggestion: When testing voice call, do not perform PS dialup on the Modem of the outgoing UE manually. Otherwise, voice call maybe hangs up abnormally. The UE that is performing PS services can serve as an incoming UE for Voice Call or Video Phone test. Thus, the CS and PS concurrent test can be performed on the same UE.
24
Huawei confidential, 2007-10

www.huawei.com

Test Plan Configuration Before Test


Parameters for Voice Call:
1.1 Call type
Continuous Call: The call continues if it does not fail, drop, or hang up. If the call fails, drops, or hangs up, Probe waits for a call interval to originate another call.

Call by Call: call: The call lasts and waits for the predetermined calling duration and call interval, and repeats for the times defined in call count.

1.2 Setup time: the maximum time for call setup. If the call cannot be setup within the defined period, the call setup fails. 1.3 Calling duration: the duration of one call, from call setup to call normal release. (apply only to call by call) 1.4 Call interval: the time between two calls, from the previous call disconnection to the beginning of the next call. 1.5 Exceptional Interval The interval between the exceptional end of a call drop and the beginning of the next call.

1.6 Count Mode: the limitations on the call number -> Finite / Infinite.
25

www.huawei.com

25
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
2. Video Phone

Suggestion: To conduct this test, the UE and the called terminal must support the video calls.
26

www.huawei.com

26
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
3. PING

27

Note: PING packet size have an effect on PING delay time. Usually, the PING packet size is described in the criterion of the test project, set the parameter according to the criterion. Otherwise we can use the default setting: 32 Bytes if there is no special requirement.
27
Huawei confidential, 2007-10

www.huawei.com

Test Plan Configuration Before Test


Parameters for PING:

28

www.huawei.com

28
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
4. Ftp Upload / Ftp Download

Note: PS connection can be set up by one FTP Download test item if correct APN has been set in UE.
29

www.huawei.com

29
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for Ftp Upload / Ftp Download:
4.1 User, Password: FTP user name and password. For anonymous login, also need to input anonymous as username. 4.2 Remote File: Destination file address, input the detailed download path, such as, ftp://10.0.0.1/download/1.dat 4.3 Local File: Local path to save the download file, such as, C:\1.dat

4.4 MultiTask Count: When we use multi-threading download, set the number of threads here. 4.5 Test Interval (sec): The time interval between multi downloads. After finishing a download, wait for serveral time, then start another times download.
4.6 FTP Count: the total number of ftp download test.

30

www.huawei.com

30
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for Ftp Upload / Ftp Download:
4.7 Disconnection Mode: the mode of Disconnection, there are three choices: Keep Disconnected: Do not perform PDP context deactivation ( remain RRC connection) after the target files are loaded completely, just wait for interval time then continue next ftp download test. Disconnect By Time: Perform PDP context deactivation periodically. The period for the PDP context deactivation is represented by the Valid FTP Duration parameter. If the target files are not loaded completely within the predefined time, the loading result shows timeout. Probe considers this loading as failure and initiates another PDP context deactivation in the next loading. Disconnect After Transfer Complete: Each time when the file load is complete, PDP context deactivation would be performed. FTP Upload: Parameters are the same with FTP downloads. Probe will upload the local file to the destination path automatically.

Make sure you have the authority to upload file before test.
31

www.huawei.com

31
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
5. HTTP

32

www.huawei.com

32
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for HTTP:
5.1 URLRefers to the destination HTTP address of the server. 5.2 PortRefers to the HTTP serving port. By default, the value is 80. 5.3 Control ModeTest by time and Test by RRC state. 5.4 Test Interval Refers to the interval between two HTTP tests. This parameter takes effect when Control Mode is Test by Count. 5.5 HTTP CountRefers to the total number of HTTP tests. This parameter takes effect when Control Mode is Test by Count.

33

www.huawei.com

33
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
6. PDP

NoteIf False is selected in Auto Dialup, the connections on the signaling plane are set up. The signaling includes RRC signaling, PDP context activation request, and PDP context activation receive message. The service plane, however, is not established. In such a situation, the PING service is not being connected. If True is selected, the connections on both signaling and service planes are established. That is, the PC <-> UE <-> CN channel is set up for dialup connection and providing services.
34

www.huawei.com

34
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for PDP:
Auto Dialup: If the option is false, then only setup signaling plane connection. In NAS Message window, we can see the Activate PDP context request & Activate PDP context accept message, but we cant perform service in this mode. If the option is true, then there will setup a connection between PC<->UE<-->CN, the same as PS Dialup, we can perform service in this mode.
Reserved Duration: The period when the PDP is in active status, thus, it is time from activate PDP context accept to deactivate PDP context request. Test Interval: If a PDP test is success, wait for Test Interval to do next PDP test. Then, it is time from deactivate PDP context accept to activate PDP context request. Exceptional Interval: If a PDP test is failed, wait for Exceptional Interval and then do next PDP Test. UL/DL Max Rate (Kbps)

UL/DL Guaranteed Rate (Kbps)


35

www.huawei.com

35
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
7. PS DaiUp / PS HangUp
The function of PS Dialup is to setup a PS connection.

36

www.huawei.com

36
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for PS Dialup:
7.1 APN: Access Point Name.
Ask the local PS domain engineer for the access point name. APN is named as huawei.com or huawei.

7.2 QoS
Traffic Class

UL Max V(kbit/s)uplink max rate


DL Max V(kbit/s)downlink max rate UL Guaranteed V(kbit/s)uplink guarantee bit rate DL Guaranteed V(kbit/s)downlink guarantee bit rate Note: For BE service, such as Background Class and Interactive Class, dont set the UL & DL Guaranteed V. The UMTS Specifications specify that BE service has no requirement on guarantee bit rate. Setting guarantee bit rate may result in PS connection setup failure for many mobiles do not support the setting.

37

www.huawei.com

37
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Supplements about APN, QoS Setting
a) If leave APN, QoS parameters blank
Probe wont send the associated command to the UE if the parameters mentioned above is not set, that is the UEs former setting will be maintained.

b) Methods for setting APNQoS and their correlationship


1) Set by AT command in MODEM initial command
2) Set by Probe in Test Plan

When both Probe and MODEM have APN and QoS information, because AT command in MODEM initial command is send to UE more closely before PS connection setup, it will replace the information send to UE by Probe. That is Probes setting doesnt work if AT command also exists in the MODEM initial command.

38

www.huawei.com

38
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
8. SMS

39

www.huawei.com

39
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for SMS:
8.1 Service Center Numberthe number of the short message service center 8.2 MessageThe short message content 8.3 Destination NumberThe destination number of the short message service 8.4 Test CountThe total number of the cyclic sending 8.5 Test IntervalInterval between two short messages.

40

www.huawei.com

40
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
9. Video Streaming

41

www.huawei.com

41
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for Video Streaming:
9.1 URLRefers to the URL address of the destination file, for example, tsp://192.168.34.154/athens/wuhuan.rm

9.2 Test Countthe number of the cyclic plays.

42

www.huawei.com

42
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
10. Multi-RAB

Note: The Multi-RAB test supports PS and CS concurrent service tests. In addition, this test provides the solution to the problem of failing to stop AMR automatic test for the same mobile phone when the dialup connection of data service is set up.
43

www.huawei.com

43
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for Multi-RAB:
10.1 Concurrent TypeThe type of a concurrent test 10.2 Startup PriorityThe sequence of sub-services in concurrent tests 10.3 FTP TypeFTP Upload / FTP Download 10.4 End TypeBy Time / By File 10.5 Test CountThe counts of test 10.6 Test IntervalThe interval between two tests 10.7 FTP Retry Countthe maximum retry times after the FTP connection fails

44

www.huawei.com

44
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for Multi-RABCont.:
10.8 FTP Timethe time for one FTP transmission ; This parameter takes effect when End Type is set By Time

10.9 CS and Ftp Intervalthe period between initiation of a call and execution of FTP service
10.10 Traffic ClassBackgroundConversationalInteractiveStreaming Subscribed 10.11 UL / DL Max Rate (Kbps) 10.12 UL / DL Max Guaranteed Rate (Kbps).

45

www.huawei.com

45
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
11. Key-Emul

NoteNot all functions of a mobile phone can be tested by executing commands. For the functions such as VP calling, MMS, and E-Mail, you can conduct automatic dialing test through the key emulation.
46

www.huawei.com

46
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for Key-Emul:
11.1 Key Emulation List 11.2 Test Interval 11.3 Test Count

47

www.huawei.com

47
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for Key-EmulCont.:

48

www.huawei.com

48
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for Key-EmulCont.:

49

www.huawei.com

49
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
12. Wait

NoteThe Wait test is used to set the time interval between two test items.
50

www.huawei.com

50
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
13. AT Control

NoteTest the AT commands on each UE before the AT control test, because the AT commands and their formats supported by different vendor differ in many ways.
51

www.huawei.com

51
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for AT Control:
13.1 Test CountThe number of the test 13.2 Command EditionRight-click the button on the right side to set the test commands in the AT Command Edit dialog box, can set test groups and add test commands for each test group.

52

www.huawei.com

52
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Parameters for AT ControlCont.:

53

www.huawei.com

53
Huawei confidential, 2007-10

Test Plan Configuration Before Test


Set Test Plan for UE
14. Stop Test

Finish the test


54

www.huawei.com

54
Huawei confidential, 2007-10

Parameter Window
Common used windows for HSDPA & R99
1. Serving, Active Set & Neighboring Cells
Display PSC, RSCP, Ec/Io for active set, monitor set and detective set In the figure, rectangle legend implicates active set data, circle implicates monitor set data, and triangle implicates detected set data. The data of the same type is distinguished from each other with different colors. Move the mouse to a place to get the scrambling code of the current point. When the UE is in idle state, PSC in active set is about the cell where the UE resides.
55

www.huawei.com

55
Huawei confidential, 2007-10

Parameter Window
Common used windows for HSDPA & R99
2. Power Control
DL SIR, SIR Target

Rx: UE received power; Tx: UE tx power

UL/DL transmit power control

56

www.huawei.com

56
Huawei confidential, 2007-10

Parameter Window
Common used windows for HSDPA & R99
3. WCDMA BLER

Displays BLER of different transport channels. In HSDPA connection mode, A-DPCH's DL BLER is being displayed.

57

www.huawei.com

57
Huawei confidential, 2007-10

Parameter Window
MAC/RLC Messages
The MAC/RLC Messages window displays the messages about Media Access Control (MAC) and Radio Link Control (RLC). The messages are visible only when the associated items in LogMask are selected.

58

www.huawei.com

58
Huawei confidential, 2007-10

Parameter Window
RRC Messages
All the UEs or single UE are displayed on the window. The messages selected on the left navigation tree are displayed. The detailed information is displayed by double-clicking on the message.

59

www.huawei.com

59
Huawei confidential, 2007-10

Parameter Window
GSM RR Messages
The GSM RR Messages window displays GSM radio resource messages. You can observe GSM RR Messages when UE is in GSM mode.

60

www.huawei.com

60
Huawei confidential, 2007-10

Parameter Window
NAS Messages
Whatever mode UE is in, WCDMA, HSDPA or GSM, all the NAS messages are displayed here as follow:

61

www.huawei.com

61
Huawei confidential, 2007-10

Parameter Window
App Throughput
Display both UL and DL application layer data rate, NAS rate and TCP retransmission rate.

62

www.huawei.com

62
Huawei confidential, 2007-10

Parameter Window
RLC Throughput
Display both UL and DL RLC layer throughput, UL PDU retransmission ratio and DL PDU error ratio.

63

www.huawei.com

63
Huawei confidential, 2007-10

Service statistics Chart


PING Service Quality Evaluation
The PING Service Quality Evaluation window displays the associated indicators on the user plane of the PING service which includes PING time, QoS, etc.

64

www.huawei.com

64
Huawei confidential, 2007-10

Service statistics Chart


PS Common Indicators
Including attach success rate, attach time, PDP activation success rate, PDP activation time are displayed here.

65

www.huawei.com

65
Huawei confidential, 2007-10

Service statistics Chart


FTP Service Quality Evaluation
Displays the associated indicators on the user plane of the FTP service, including Login time, download time, download rate, etc.

66

www.huawei.com

66
Huawei confidential, 2007-10

Service statistics Chart


HTTP Service Quality Evaluation
Displays the associated indicators on the user plane of the HTTP service, such as page access time, page download time and page down load rate, etc.

67

www.huawei.com

67
Huawei confidential, 2007-10

Contents

GENEX Overview GENEX Probe General workflow

Using Probe for HSDPA / HSUPA DT data collection


Other Features Case Study

68

www.huawei.com

68
Huawei confidential, 2007-10

Parameter Window
HSDPA Parameters window
1. HSDPA Physical Channel Window

69

www.huawei.com

69
Huawei confidential, 2007-10

Parameter Window
HSDPA Parameters window
1. HSDPA Physical Channel Window (cont.)

70

www.huawei.com

70
Huawei confidential, 2007-10

Parameter Window
HSDPA Parameters window
2. HSDPA Decoding Statistics

71

www.huawei.com

71
Huawei confidential, 2007-10

Parameter Window
HSDPA Parameters window
3. HSDPA Link Statistic

72

www.huawei.com

72
Huawei confidential, 2007-10

Parameter Window
HSDPA Parameters window
3. HSDPA Link Statistic (cont.)
Item
Scheduled Rate-Delta
Scheduled Rate-Average

Description
Instantaneous rate that the MAC layer schedules
Average rate that the MAC layer schedules Instantaneous rate at which the MAC layer transmits. The transmission here includes Transmission failure and Re-transmission Average rate at which the MAC layer transmits. The transmission here includes: Transmission failure and Re-transmission Instantaneous rate at which the MAC layer transmits. The transmission here excludes: Transmission failure and Re-transmission Average rate at which the MAC layer transmits. The transmission here excludes: Transmission failure and Re-transmission Instantaneous success rate of the HS-SCCH channel Average success rate of the HS-SCCH channel

Served Rate-Delta

Served Rate-Average

MAC Layer Rate-Delta

MAC Layer Rate-Average


HS-SCCH Success RateDelta HS-SCCH Success RateAverage
73

www.huawei.com

73
Huawei confidential, 2007-10

Parameter Window
HSDPA Parameters window
3. HSDPA Link Statistic (cont.)

74

www.huawei.com

74
Huawei confidential, 2007-10

Parameter Window
Supplement for HSDPA Link Statistic:
1. Delta vs Average
Delta is the average value in 200ms.

Average is the average value from the beginning of stat. to the current time. You can choose to clear the former stat. data. The values displayed by Assistant are all belong to Delta series.

2. Parameters about rate


Scheduled Rate = The total block size scheduled to the UE during stat. time / (Total time slot scheduled to the UE * 2ms)
Served Rate = The total block size scheduled to the UE during stat. time / stat. time length

HS-SCCH Success Rate = time slot number scheduled to the UE during stat. time / total time slot number during stat. time
When multi UEs share a HS-SCCH channel, they will share channel resource. So, HS-SCCH Success Rate reflects the time ratio of a UE occupies HSDPA resource. The closer to 100% of total HS-SCCH Success Rate from UEs who share a HS-SCCH channel, the better schedule performance the system has.

Served Rate = Scheduled Rate * HS-SCCH Success Rate Mac Layer Rate = Served Rate * (1- SBLER)
75

www.huawei.com

75
Huawei confidential, 2007-10

Parameter Window
Supplement for HSDPA Link Statistic: 3. IBLER, SBLER vs Res.BLER
IBLER is 1st MAC-hs error block /total 1st MAC-hs transmission blocks. IBLER Target can be configured on NodeB. And its statistic value in Probe is 1st SBLER in HSDPA Decoding Statistic Window. SBLER is MAC-hs error block / total MAC-hs transmission blocks, IBLER target configured on NodeB have an effect on SBLER, now the common value range of SBLER is 10%~15%. Res.BLER means remain BLER, which is within RLC layer. One transmission block only after multi-times unsuccessful MAC-hs retransmission, will be calculated as RLC layer error block, stat. to Res.BLER. Res.BLER is approximate to 0 in normal instance.

76

www.huawei.com

76
Huawei confidential, 2007-10

Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration

77

www.huawei.com

77
Huawei confidential, 2007-10

Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration (Cont.)

78

www.huawei.com

78
Huawei confidential, 2007-10

Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration (Cont.)

79

www.huawei.com

79
Huawei confidential, 2007-10

Parameter Window
HSUPA Parameter Window
1. HSUPA DL Channel Configuration (Cont.)

80

www.huawei.com

80
Huawei confidential, 2007-10

Parameter Window
HSUPA Parameter Window
2. HSUPA UL Channel Configuration

81

www.huawei.com

81
Huawei confidential, 2007-10

Parameter Window
HSUPA Parameter Window
3. HSUPA Link Statistics

82

www.huawei.com

82
Huawei confidential, 2007-10

Parameter Window
HSUPA Parameter Window
3. HSUPA Link StatisticsCont.

83

www.huawei.com

83
Huawei confidential, 2007-10

Contents

GENEX Overview GENEX Probe General Workflow

Using Probe for HSDPA / HSUPA DT Data Collection


Other Features Case Study

84

www.huawei.com

84
Huawei confidential, 2007-10

2G/3G re-selection and handover test


2G/3G re-selection and handover test
Synchronous decoding of 2G/3G messages 2G/3G power information and cell information Events can be displayed in various modes

WCDMA window

GSM window

Check handover time in event window


Customized window
85

www.huawei.com

85
Huawei confidential, 2007-10

Scanner test
Professional Scanner test
Top N pilot test Specified pilot test Spectrum analysis
Multi-frequency test

Multi-frequency scanning
Multi-path signal analysis CW test

Top N Pilot test

Spectrum test
86

Multi-path signal analysis


Huawei confidential, 2007-10

www.huawei.com

86

Indoor test
Support indoor test
Vertical test Walking test

Automatic
Manual
Walking test

Vertical test

87

www.huawei.com

87
Huawei confidential, 2007-10

Events auto-detection
Rich and comprehensive predefined events, for example, call setup, call drop, handover and so on Data service analysis events 2G/3G handover events Events displayed on graphs and maps Co-Activation of event, signaling data and measurement data facilitates problem location

Customized event icons and alert tones

Handover Complete

Attention! Call Drop!!

88

www.huawei.com

88
Huawei confidential, 2007-10

Enhanced map display


Friendly interface of drive-testing
Loading log files as a navigation of test Multi-layers display on map, and user can set offset to any one Supports SC reuse scene

Event and track preview

Layer offset
89

www.huawei.com

89
Huawei confidential, 2007-10

Project Template
Project Template
Site Verification
Optimize Benchmark

Acceptance
Customize
The Probe supports customizing and loading project templates. All the project templates are stored in the sub-folder of the Template Project folder. When the Probe is being installed, the following default folders of different categories are generated. You can also set custom project templates and save them in the directory. When multiple tests with a similar function are being performed, you can directly open the corresponding project template but need not carry out repeated project settings.
90

www.huawei.com

90
Huawei confidential, 2007-10

Log file replay

1. 2.

Parameter Window layout Open log file

5. Locate event

Route and event preview

3. Set play speed 4. Play log file

91

Logfile playing, multi-window co-activation

www.huawei.com

91
Huawei confidential, 2007-10

Export Data
Basic procedure of Probe data export

1. select Export data

2. select target format

3. set source file, destination file and data range

Data Format
Bin Text QXDM (Qualcomm data format) Excel

5. start export

4. select device and Log item to export

* Exported data used for post-processing of CW Measurements data, data geographic binning and filter.
92

www.huawei.com

92
Huawei confidential, 2007-10

Setting an Auto View


Setting an Auto View Funtion You can open the configured window or page by selecting a button on the toolbar.

93

www.huawei.com

93
Huawei confidential, 2007-10

Setting an Auto View


Setting an Auto View Funtion The Auto View Config dialog box consists of five tab pages that share the Auto open and arrange control. If you select the Auto open and arrange check box, the system creates the configured page and the page view configured in the page after the auto view is configured. UE Common

UE Overview
UE Service Stat.

DTI Scanner
Anritsu Scanner

94

www.huawei.com

94
Huawei confidential, 2007-10

Setting an Auto View


UE Common

1. Page Name Default Setting: Messages 2. Page View Select the needed View Window.

95

www.huawei.com

95
Huawei confidential, 2007-10

Setting an Auto View


UE Overview 1. Set the view and page name for every UE under test on this tab. This type of view is irrespective of the test plan configuration.

96

www.huawei.com

96
Huawei confidential, 2007-10

Setting an Auto View


UE Service Stat.

97

www.huawei.com

97
Huawei confidential, 2007-10

Setting an Auto View


UE Service Stat.

98

www.huawei.com

98
Huawei confidential, 2007-10

Setting an Auto View


DTI Scanner

Page Name: Default Setting is DTI Pilot scan; Every test Item has a default View.

99

www.huawei.com

99
Huawei confidential, 2007-10

Setting an Auto View


Anritsu Scanner 1. You can set the view and page name for testing Anritsu Scanner on this tab. This type of view is irrespective of the test plan configuration. 2. By default, the Page Name is set to Anritsu Pilot scan and each test item has its corresponding view.

100

www.huawei.com

100
Huawei confidential, 2007-10

Convenient View
Navigation View

On the left of the soft, include five Page: ProjectControlConfigurationView


Property.

101

www.huawei.com

101
Huawei confidential, 2007-10

Contents

GENEX Overview GENEX Probe General Workflow

Using Probe for HSDPA / HSUPA DT Data Collection


Other Features Case Study

102

www.huawei.com

102
Huawei confidential, 2007-10

Contents

Case1. Inter-RAT handover test Case2. WCDMA inter-frequency handover test Case3. Multi-frequency Scanning

103

www.huawei.com

103
Huawei confidential, 2007-10

Case1. Inter-RAT handover test


Inter-RAT handover test

Event observation Location of handover point

104

www.huawei.com

104
Huawei confidential, 2007-10

Case1. Inter-RAT handover test


Inter-RAT handover

Time of Handover signaling

Messages and measurement from different networks

105

www.huawei.com

105
Huawei confidential, 2007-10

Case2. WCDMA inter-frequency handover test


WCDMA inter-frequency handover

The signal frequency in active set is 2137.40 when the test starts
Signaling window

Log file:
106

www.huawei.com

106
Huawei confidential, 2007-10

Case2. WCDMA inter-frequency handover test


WCDMA inter-frequency handover process
Signaling observation before handover

107

www.huawei.com

107
Huawei confidential, 2007-10

Case2. WCDMA inter-frequency handover test


WCDMA inter-frequency handover process

Observe it again, and the frequency handover to 2132.40


108

www.huawei.com

108
Huawei confidential, 2007-10

Case3. Multi-frequency Scanning


Simultaneous scanning of multifrequency
2. Scanned multifrequency

1. Set multi-frequency

3. Select specified frequency to observe it


109

www.huawei.com

109
Huawei confidential, 2007-10

Case3. Multi-frequency Scanning


Simultaneous scanning of multi-frequency
Simultaneous observation of different frequencies

110

www.huawei.com

110
Huawei confidential, 2007-10

www.huawei.com

Huawei confidential, 2007-10

También podría gustarte