Está en la página 1de 14

UNIVERSITY OF THE EAST CALOOCAN

COLLEGE OF ENGINEERING

Experiment no.1
INSTRUMENT FOR MEASUREMENT OF
ELECTRICAL QUANTITIES AND OHMS LAW

Submitted To:
Engr. ANTONIO C. REBONG
EE Professor

Submitted By:
DELLOMAS, RODEL, M.

20131124306

STUDENT NUMBER

GROUP 2

JUNE 15, 2O15

DATE OF PERFORMANCE
SUBMITTED

JULY 6, 2015
DATE

List of instruments
Equipment, instruments and materials needed

UniTrain-I Interface with virtual instruments (basic VI)


The measurement interface is the central unit of the desktop lab. It
incorporates all inputs and outputs, switches, power and signal Sources and
measurement circuitry needed to perform Experiments.
Equipment:
32-bit processor with storage memory for measurements
USB interfaces, transfer rate 12 Mbits/s
Simultaneous connection of any number of Experimenters
Via serial bus system
Analog output, +/- 10 V, 0,2 A, DC 1 MHz, via BNC and
2-mm sockets
2 Analog differential amplifier inputs with 4 MHz
Bandwidth, safe for voltages up to 100 V, sampling rate
40 mega samples, 9 measuring ranges, memory depth 2 x
16 k x 10 bit, inputs via BNC or 2-mm socket
16-bit digital signal output, of which 8 bits are accessed
Via 2-mm sockets, TTL / CMOS, clock frequency 0
100 kHz, electric strength +/- 15 V
16-bit digital signal input, of which 8 bits are accessed via
2-mm sockets, memory depth 16 bit x 2 k, TTL / CMOS,
Sampling rate 0 100 kHz, electric strength +/- 15 V,
8 Relays 24V DC / 1 A, of which 4 are accessed via 2-mm
Sockets
Dimensions: 28 x 19 x 9 cm

Weight: 1.7 kg
Power supply with wide range input 100-250 V, 50-60 Hz,
Outputs 2 x +/- 15 V/0, 4 A; 2 x 5 V/1 A

UniTrain-I Experimenter
UniTrain-I Experimenter for coupling to the UniTrain-I Interface or to
Other experimenter modules.
Equipment:
Connects to the UniTrain-I Interface and additional
Experimenters via UniTrain-I bus
UniTrain-I bus connection for experiment cards
Direct connection to the standard UniTrain-I power supply for
use without an UniTrain-I Interface
Fixed and variable voltages available via 8 2-mm sockets
Accommodates UniTrain-I experiment cards
Accommodates a breadboard for experimenting with discrete
components and integrated circuits
Accommodates a multimeter using IrDa interface
Dimensions: 28 x 19 x 9 cm
Weight: 0.5 kg

UniTrain-I extended power supply


Supplementary power supply unit for UniTrain-I system. This
power supply unit is used in addition to the basic power supply
unit where variable higher-power alternating voltages, adjustable
higher-power direct voltages or a three-phase current system with
variable frequencies and amplitudes are required for experiments.
The UniTrain-I Interface is required for the power supply
generation functions. Adjustment is carried out with virtual

instruments.
Mains input: 100 - 250 V AC, 50 - 60 Hz via IEC socket
(non-heated devices) and included mains cable
Output: 2 x 24 V / 2 A via cable approx. 2 m long with 6pin DIN socket
Dimensions: 187 x 100 x 76 mm (L x W x H)
Weight: 1.3 kg

Metrahit Multimeter
Universal precision lab multimeter and temperature meter with IR
interface for high-quality, universal measurement and testing in
educational settings, power plants, process control installations etc.
3-digit multimeter; resolution: 3,100 digits
Measurement classification CATII-1000V
Can be connected to UniTrain-I system via IR interface
Voltage and current measuring ranges: 30mV-1000V DC, 3V1000V AC; 3mA-16A DC; 30mA-10A AC
Resistance ranges: 30ohm-30Mohm
Special functions: C for temperature measurements using
PT100/1000 thermocouple
Continuity and diode testing
Automatic range selection and battery shut-off, min./max. and
data hold function
Safety fuse for current measurement range up to 300mA
Protection against high currents in the mA range for nominal
voltage of 1000V
Display with bar chart and backlighting
Includes protective sleeve, measuring leads, 1 x spare fuse,
9V battery, calibration certificate
Experimental Card DCCL No.1and Connection Plugs
Shunt resistors on a PCB, for current measurement using the
analog inputs of the UniTrain-I system.
6 Shunt resistors: 2 x 1 ohm, 2 x 10 ohm, 2 x 100 ohm
Screen print of symbols for identifying resistors, the

voltage taps and current inputs


24 x 2-mm sockets
Dimensions: 100 x 40 mm
Set of connection cables 2mm (22 pcs) for UniTrain-I consisting
of:
8 x connection leads 2mm, 15cm, blue
4 x connection leads 2mm, 15cm, yellow
2 x connection leads 2mm, 45cm, black
2 x connection leads 2mm, 45cm, yellow
2 x connection leads 2mm, 45cm, red
2 x connection leads 2mm, 45cm, blue
2 x adapter leads 4mm to 2mm, 50cm, white
10 x 2-mm connector plugs / Plug spacing 5 mm

Data
Table 1.1
Measured and computed value of resistance for different loading
resistor connection
Measured
computed
trial
Loading resistor connection
Value in k Value in
k
1
Four resistors in series
4.82 k
4.824 k
2
Three resistors in series
3.74 k
3.618 k
3
Two resistors in series
2.412 k
2.412 k
4
One resistor
1.206 k
1.206 k
5
One resistor in parallel with
three in series
0.906 k
0.9045 k
6
One resistor in parallel with
two in series
0.804 k
0.804 k
7
Two resistors in parallel
0.603 k
0.603 k
8
Two resistors in parallel with 2
resistors in series
0.483 k
0.4824 k
9
Three resistors in parallel
0.41 k
0.402 k
10
four resistors in parallel
0.32 k
0.3015 k
Measured value of resistance of one resistor: 1.206 k

Table 1.2
Measured value of resistance of a potentiometer at different
Voltage
(volts)

trial

Current
(ma)

3.5 ma
6.5 ma
9.5 ma
12.4 ma
15.4 ma
Position settings

1
2
3
4
5

2
4
6
8
10

trial

1
2
3
4
5

Position
setting
Of
potentiometer
0%
25%
50%
75%
100%

Power
(watts)
0.007W
0.026W
0.957W
0.0992W
0.154W

Measured value
of resistance
(ohms)
2.65
1771
4450
7370
8530

Table 1.3
Voltage-current relations with fixed value of resistance

Table 1.4
Resistance-current relations with fixed value of voltage
Current

trial

Resistance
(ohms)

1
2
3
4
5
6
7
8
9
10

4.82X103
3.74X103
2.412X103
1.206X103
0.906X103
0.804X103
0.603X103
0.483X103
0.410X103
0.302X103

2.5 ma
3.1 ma
4.4 ma
8 ma
10.5 ma
11.7 ma
15.4 ma
19.1 ma
22.7 ma
29.9 ma

(ma)

Power
(watts)
0.0301w
0.0359w
0.47w
0.077w
0.998w
0.1101w
0.143w
0.176w
0.2113w
0.269w

Computations

Exercises

Answers to questions and


problems

Discussion

Conclusion

Answers to questions and


problems

Reference